Regulatory authority use EMC PARTNER's HAR1000 to enforce Harmonic and Flicker CE requirements in Germany

Size: px
Start display at page:

Download "Regulatory authority use EMC PARTNER's HAR1000 to enforce Harmonic and Flicker CE requirements in Germany"

Transcription

1 Emission Measurements Regulatory authority use EMC PARTNER's HAR1000 to enforce Harmonic and Flicker CE requirements in Germany Martin Lutz, Reto Casanova, Nicholas Wright Contents 1. Introduction Important points when selecting a Harmonics and Flicker measurement system Measurement of HAR1000-1P at RegTP in Berlin... 6

2 1. Introduction The Regulatory Authority for Telecommunication and Post (RegTP), is a high level federal authority within the Federal Ministry of Economics and Labour, with headquarters in Bonn Germany. The Authority was established on 1st January 1998 with the aim of enforcing European regulations relating to CE marking. HAR1000s have been purchased to support the RegTP in fulfilling this aim. RegTP has effective procedures and instruments with which to enforce the regulatory aims, these include information and investigative rights as well as sanctions against transgressors. In September 2003, the German RegTP ordered 12 HAR1000-1P Harmonic & Flicker systems with an option on a further 13 units which they took up in June Making a total of 25 systems. The request was based on a public tender dated 2nd September 2003 for Harmonics and Flicker measurement systems. The Technical specification of the tender stated that the equipment should comply with the following published standards IEC Harmonic Measurements IEC Flicker Measurements IEC Definition of Harmonic measurement systems When the RegTP awarded the tender to EMC PARTNER, the failed bidders attempted to discredit the HAR1000 and EMC PARTNER. Neither attempt succeeded. The RegTP did however decide to test two units before accepting delivery of the remaining 10. Exhaustive tests on the HAR1000s carried out by RegTP personnel did show some discrepancies that had to be rectified before they could accept delivery of these units. EMC PARTNER classified these discrepanices into 2 areas, minor software anomalies and, minor hardware issues. EMC PARTNER resolved the minor software glitches immediately and the hardware issues were defined as the following: 1. Conducted emissions in the frequency range 150 khz to 30 MHz were too high. 2. Flicker measured above 1.8 kw was not correct because the HAR1000 amplifier could not compensate for disturbances and the voltage drop of the EUT. 3. The tender specified an A/D converter type not used in HAR1000. These issues were consequently investigated and resolved by the following actions: 1. Emission measurements showed that the Pentium computer used in the HAR1000 was the source of this disturbance. The original 288 MHz computer used in HAR1000 was verified by an accredited Swiss test house and the emission levels were within specification. The problem was solved by additional filters in Pentium equipped HAR1000s. 2. Software in the HAR1000 was updated to guarantee the amplifier can compensate all disturbances on the power supply up to a power rating of 2 kw. 3. The A/D converter type was replaced by the type specified. Comparisons show there is no difference in test results obtained using the original HAR1000 and the new A/D converter types. 4. Additionally the software was updated to comply with the latest IEC requirements (200 ms measuring windows and the inclusion of interharmonics). 2 In a second test round with the 2 modified HAR1000 units, a detailed verification

3 program was carried out by RegTP and EMC PARTNER personnel. The HAR1000 was accepted as fully meeting the tender specification and all remaining units were delivered. 2. Important points when selecting a Harmonics and Flicker measurement system When selecting a solution for Harnomic and Flicker testing a number of issues need to be considered. Over the past ten years many issues have been introduced which are based more on the limitations of available measurement systems or to "justify" the cost of over-priced system's non-relevant features. This section attempts to clarify some of the more important selection considerations and why these are applicable. 2.1 Amplifiers To measure Harmonics or Flicker correctly, a linear amplifier must be used, to prevent distortion on the public power supply from influencing measurement results. It has been claimed that the HAR1000 uses an active filter instead of an amplifier and therefore the measurement results will be influenced by disturbances and impedance of the public power supply. EMC PARTNER's Comments HAR1000 uses an amplifier with limited working range. Within its working range the amplifier is equivalent to a full range amplifier. During Flicker measurements the amplifier reduces power supply impedance to nearly zero Ohm and during Harmonics measurement the power supply harmonic distortion is maintained below the limit of IEC The voltage distortion is continuously checked and included in the test report. Measurements made by RegTP, back-up the EMC PARTNER statement. HAR1000-1P including harmonics and flicker analysis, amplifier and LIN 2.2 Standard compliance Changes to the standards, particularly for Harmonics & Flicker, have been frequent. Sometimes changes have been introduced before test equipment to the old version has been established on the market. This is frustrating for users and test equipment manufacturers alike but reflects the complexity of the subject. Major issues with the first Harmonics standard published 1995 were the class D evaluation and non repeatable measurement results for fluctuating Harmonics. These two points, along with other housekeeping issues have been taken care of in Amendment 14 or IEC Ed.2.1 published Class D is now limited to only a few product types which are listed in the standard and the measurement and calculation of Harmonics has been change to an averaging method. Finally IEC published 2002 has resolved problems of harmonic measurement on 50 and 60 Hz power supplies and the increased interharmonics caused be counter measure such as Power Factor Correction (PFC). EMC PARTNER's Comments EMC Partner has always updated the HARCS software to meet latest published standards within a short time period. Updates for existing HAR1000 customers are avaialble as free downloads from our website (www-emc-partner.com). HARCS software versions >4.01 include all measurement techniques called out in the above standards. 3

4 Flicker emission measurement with the HARCS Software Harmonic emission measurement with the HARCS Software 2.3 Use of Windows software Windows software cannot be used for real time processes such as the Fourier analysis used in Harmonic measurements. EMC PARTNER's Comments HAR1000 only uses Window software to provide the user interface and for data presentation. This has many advantages for users, who are able to evaluate measurement results in a clear visual format. Inside HAR1000 is a separate PC which runs firmware in real time to perform the Fourier analysis. 2.4 Using Windows 2000 or Windows XP Windows 2000 and Windows XP have particular requirements over previous versions. EMC PARTNER's Comment Earlier versions of HARCS software did have problems communicating under Windows 2000 or XP. The problem has been overcome by using HAR1000 on a USB port through a USB to Serial converter. 2.5 Harmonic Current Measurement Accuracy IEC defines the measurement accuracy to be within 5 % of the limits or 0.2 % of the nominal current. EMC PARTNER's Comment HAR1000 guarantees this accuracy for currents between 30% and 100% of the nominal (EUT current). Should the current drop below 30% of the selected measurement range, the range will automatically be switched, or if manual mode is selected, a message is displayed suggesting the operator change ranges. 2.6 The 2.5 minute test time myth There is a myth that a test time of 2.5 minutes for harmonic testing is a requirement. 4

5 EMC PARTNER's Comment IEC does not specify a test time of 2.5 minutes. The 2.5 minutes mentioned is an observation period. Test time for each product is different and will be greater than the 2.5 minute observation period. 2.7 IEC specifies a voltage range of 400 V IEC specifies a measurement system for single AND three phase systems up to 400 V. EMC PARTNER's Comment HAR1000-1P is a single phase measurement system suitable for L to N voltages up to 280 V. The three phase HAR1000-3P is designed for voltages up to 415 V between phases. The HAR1000 system provides its users a choice and investment protection that fulfils the IEC requirement for both one and three phase product testing. 2.8 The test system should deliver 16 A to an EUT There is a mis-conception that part of the EUT input current is used for the power amplifier in HAR1000, thus reducing EUT power availability and the operating range of HAR1000. EMC PARTNER's Comment The innovative solution of EMC PARTNER enables 16 A EUTs to be tested to full rating. Power for the amplifier is separate to the EUT power. HAR1000 can be used on public power supplies rated to 16 A because of the separate connection solution. Total power consumption consists of the EUT power (maximum 16 A) plus the amplifier and controller power rated separately at 5 A. 2.9 Power supply impedance must be reduced to nearly zero Ohm The public power supply has an impedance which is not constant at every location. In order to accurately determine Flicker levels, voltage fluctuations can only be measured over a defined impedance. The impedance value for Flicker measurements is specified in the IEC for single phase to be j 0.25 and for three phase to be j 0.15 (Line) and j 0.10 (Neutral). It is therefore essential to eliminate the undefined public power supply impedance. EMC PARTNER's Comment HAR1000 uses an amplifier to compensate the public power supply to zero Ohm impedance. Measurements by the RegTP verified this important point. Every HAR1000 owner can easily verify this (see measurement 3.3). 3.0 Verification of hardware impedance network It is desirable, during instrument calibration, to verify the LIN hardware. These components, used for Flicker measurement provide a defined network impedance of j EMC PARTNER's Comment HAR1000 has both a hard and software Line Impedance Network (LIN). Verification is made easier by plugs on the HAR1000 rear panel. These give direct access to the hardware LIN components. 5

6 3. Measurement of HAR1000-1P at RegTP in Berlin 3.1 Measurements with Harmonics analyser RegTP had prepared some special loads to be used for verification of the Harmonic analyser. The loads have well defined emissions verified indepedantly by previous measurements. Results obtained using the HAR1000 were always well within the accuracy requirements of the IEC standard. HAR1000 results compared very favourably with measurement taken on other test systems. As a consequence, more emphasis was placed on verifying the source (HAR1000 amplifier) and the Flicker analyser. 3.2 Testing effectiveness of the HAR1000 amplifier RegTp had recorded waveforms of the public power supply in several of their laboratories which indicated both flat-top and over-swing distortions were present. These waveforms were recreated using a programmable voltage power supply and used as the EUT supply input to the HAR1000. Both with and without loads up to 2 kw, HAR1000 amplifier was able to compensate the distortion and deliver a clean sinusoidal waveform to the EUT. 3.3 Testing the Flicker analyser For Flicker measurement it is important that the amplifier can compensate the impedance of the public power supply to zero Ohms Verifying LIN influence and correct operation of the amplifier for Flicker measurements clean source low impedance U1 230 V ampli LIN reference load EMC PARTNER Monitor Measurement and Analysis of the HARMONICS-1000 reference analysators Block diagram of the HAR1000 Important Note: Each block illustrated above is a discreet hardware part of the HAR1000. Each block can be switched in or out of circuit by the HARCS software Verification procedure 1. A load of 2000 W is switched ON and OFF with a repetition of 1 second. 2. The amplifier is turned OFF and the LIN is switched ON. 3. A high impedance public power supply is simulated by 50 m of power cable wound on a cable drum. 6

7 Flicker measurement results of the verification set-up (without amplifier) 4. The amplifier is turned ON and the LIN is turned OFF 5. The measurement is repeated. Short time Flicker is below 0.09 much better than the standard specification (0.4) Flicker generated by the high impedance power supply and additional 50 m cable is completely compensated by the HAR1000 amplifier. 6. Switch ON the LIN Correct measurement of Flicker The value Pst is only generated by the impedance of the LIN. The influence of the public power supply impedance is compensated by the HAR1000 amplifier. 7

8 3.3.3 Verification of the hardware LIN. LIN Resistance Neutral LIN Resistance Phase LIN Inductance Phase and Neutral Location of hardware LIN components The hardware LIN is made of a resistance in series with an inductor. Both components can be independantly verified using the procedures detailed. R = 0.4 ohm j = 0.25 ohm Line Impedance Network (LIN) Impedance Verification (j) Measure voltage at the HAR1000 rear panel connectors and load current as indicated in the diagram below: V Amplifier on MC-Plugs Brown LIN = on/off L in L out 0.24+j V Line Flickermeter Load about 2kW LIN = on/off N in N out 0.16+j0.10 MC-Plugs White Location of MC-Plug measurement points V Apply a 2 kw load to the HAR1000. This generates approximately V. System conditions : Amplifier = on ; Line Voltage = 230 V ; Load = 8.5 A Complete the table below using measured values of V & A. 8

9 LIN Voltage drop At current Impedance dv / A [V] [A] [ohm] Phase [L]??? Neutral [N]??? Nominal value calculation : Xz = (0.4)2 + (0.25)2 = Ohm Allowable tolerance ± 5% = to Important Note: To reduce transition resistance of the LIN bypass relays, switch off the LIN with EUT-Power Input and load on Power Output connected Resistance Verification (R) Measure Resistance at the HAR1000 EUT output connectors and connect a short circuit to EUT power input as indicated in the diagram below: Amplifier = off LIN = on/off L in L out 0.24+j0.15 Short circuit Flickermeter Precision Ohmmeter LIN = on/off N in 0.16+j0.10 N out Connection of a short circuit to a EUR power input System conditions : Amplifier = off ; Line Voltage = 0 V Complete the table below using measured values of R from the precision ohmmeter. LIN Resistance DifferenceR(on) - R(off) [ohm] [ohm] OFF ON Lout to Nout Lout to Nout Contact Nominal value : Ohm +/- 5% = to ohm 9

10 10

11 11

12 For further information please do not hesitate to contact EMC PARTNER s representative in your region. You will find a complete list of our representatives and a lot of other useful information on our website: The Headquarters in Switzerland EMC PARTNER AG Baselstrasse 160 CH Laufen Switzerland Phone: Fax: sales@emc-partner.ch Web-Site: Your local representative 12 Version July Subject to change without notice. Copyright by EMC PARTNER AG, Switzerland.

Low Frequency Measuring System

Low Frequency Measuring System Emission Measurements Low Frequency Measuring System Brief Overview of Phenomena............... 2 Applicable Standards................... 3 Test System Overview.................. 4 Generator Specifications.................

More information

Low Frequency Measuring System

Low Frequency Measuring System Emission Measurements Low Frequency Measuring System Brief Overview of Phenomena................ 2 Applicable Standards................... 3 Test System Overview................... 4 Generator Specifications..................

More information

Combination Wave Test System

Combination Wave Test System Immunity Tests Combination Wave Test System Brief Overview of Phenomena............... 2 Applicable Standards................... 3 Test System Overview.................. 4 Generator Specifications.................

More information

MILITARY & AEROSPACE TESTING

MILITARY & AEROSPACE TESTING EMC PARTNER CONDUCTED SUSCEPTIBILITY MILITARY & AEROSPACE TESTING WHEN GETTING RESULTS MATTERS THERE IS ONLY ONE CHOICE Military and avionic testing is all about quality and precision. MIL3000 brilliantly

More information

Insulation Test System

Insulation Test System Component Tests Insulation Test System Brief Overview of Phenomena............... 2 Applicable Standards................... 3 Test System Overview.................. 3 Generator Specifications.................

More information

Insulation Test System

Insulation Test System Component Tests Insulation Test System Brief Overview of Phenomena............... 2 Applicable Standards................... 3 Test System Overview.................. 3 Generator Specifications.................

More information

Telecom Test System. Lightning Tests

Telecom Test System. Lightning Tests Lightning Tests Telecom Test System Brief Overview of Phenomena............... 2 Applicable Standards................... 3 Test System Overview.................. 4 Generator Specifications.................

More information

VERI50 EFT for EFT calibration applicable to all TRA2000 generators and CDN2000 coupling filters

VERI50 EFT for EFT calibration applicable to all TRA2000 generators and CDN2000 coupling filters VERI50 EFT for EFT calibration applicable to all TRA2000 generators and CDN2000 coupling filters Revised: 21.December 2010 1 General Information To oscilloscope VERI50 EFT To generator 1.1 Technical data

More information

Avionics Test System. Lightning Tests

Avionics Test System. Lightning Tests Lightning Tests Avionics Test System Avionics Test System Overview 2 Features & Benefits 4 Application Options 6 Applicable Standards 7 Generator Specifications 8 Accessories and Options 10 Software 17

More information

EMC PARTNER. DO-160 & MIL-STD-461G TEST SYSTEM Indirect Lightning Testing

EMC PARTNER. DO-160 & MIL-STD-461G TEST SYSTEM Indirect Lightning Testing EMC PARTNER DO-160 & MIL-STD-461G TEST SYSTEM Indirect Lightning Testing This document has been optimized for electronic media Accredited Calibration Quality at EMC PARTNER is based on an ISO 9001 management

More information

Easy-to-Use RF Device & User-Friendly Windows Software

Easy-to-Use RF Device & User-Friendly Windows Software itest+ PicoTime-1U Spec November 30, 2015 Low Cost/Profile High Resolution Frequency Stability Measurement Test Set Pico Second Resolution Instrument Easy-to-Use RF Device & User-Friendly Windows Software

More information

AC Sources for IEC 1000 Harmonics and Flicker Testing

AC Sources for IEC 1000 Harmonics and Flicker Testing APPLICATION NOTE #101 IEC 1000-3-2 and IEC 1000-3-3 The IEC 1000-3 standard is concerned with the quality of the utility line power. To ensure good power quality, this standard specifies limits for the

More information

PURCHASE DIVISION DEPARTMENT QUALITY MANUAL Revision No. : 02 Issue No: : 2 Dt of Revision : Issue Dt. :

PURCHASE DIVISION DEPARTMENT QUALITY MANUAL Revision No. : 02 Issue No: : 2 Dt of Revision : Issue Dt. : Section : 0 Document : DQM-01 Topic : FORMAT 6 OF PROCUREMENT PROCEDURE OF CPRI (NON-WORKS) Section I(B)-Technical Specification Tender Enquery No PUR/UARC-02/14-15 Name of the Equipment: Damped Oscillatory

More information

MSO Supplied with a full SDK including example programs Software compatible with Windows XP, Windows Vista and Windows 7 Free Technical Support

MSO Supplied with a full SDK including example programs Software compatible with Windows XP, Windows Vista and Windows 7 Free Technical Support PicoScope 2205 MSO USB-POWERED MIXED SIGNAL OSCILLOSCOPE Think logically... 25 MHz analog bandwidth 100 MHz max. digital input frequency 200 MS/s mixed signal sampling Advanced digital triggers SDK and

More information

HV / MV / LV electrical network quality analyzers Class A. Communication port: local, modem, integrated Ethernet, multi-point

HV / MV / LV electrical network quality analyzers Class A. Communication port: local, modem, integrated Ethernet, multi-point 2010 MAP Range HV / MV / LV electrical network quality analyzers Class A > Network quality Analyzers PRODUCT ADVANTAGES COMPLIANT with the EN 61000-4-30 standard, Class A DETECTION of the fault LOCATION

More information

PM6000. Voltech. Power Analyzer

PM6000. Voltech. Power Analyzer Voltech PM6000 Power Analyzer A New Standard in Power Analysis Up to 6 wattmeter channels Basic accuracy: 0.02% of reading Bandwidth: 10MHz Easy-to-use in all applications The Voltech PM6000 Power Analyzer

More information

FREJA 306 Relay Testing System

FREJA 306 Relay Testing System Relay Testing System A Megger Group Company FREJA 306 Relay testing system FREJA 306 is the latest member of the relay testing equipment from Programma, quick and easy to use, like the FREJA 300. The rugged

More information

GT-1050A 2 GHz to 50 GHz Microwave Power Amplifier

GT-1050A 2 GHz to 50 GHz Microwave Power Amplifier Established 1981 Advanced Test Equipment Rentals www.atecorp.com 800-404-ATEC (2832) Giga-tronics GT-1050A Microwave Power Amplifier GT-1050A 2 GHz to 50 GHz Microwave Power Amplifier Operation Manual

More information

SHF Communication Technologies AG

SHF Communication Technologies AG SHF Communication Technologies AG Wilhelm-von-Siemens-Str. 23D 12277 Berlin Germany Phone +49 30 772051-0 Fax +49 30 7531078 E-Mail: sales@shf.de Web: http://www.shf.de Datasheet SHF 78120 D Synthesized

More information

ESD MODULAR HANDHELD TESTER Electrostatic Discharge Testing

ESD MODULAR HANDHELD TESTER Electrostatic Discharge Testing ESD3000 - MODULAR HANDHELD TESTER Electrostatic Discharge Testing Accredited Calibration Quality at EMC PARTNER is based on an ISO 9001 management system. This is the foundation for an ISO 17025 accreditation

More information

CS114 + CS115 + CS116

CS114 + CS115 + CS116 System description Test Setup for MIL-STD-461 D, E&F CS114 + CS115 + CS116 1. MONTENA EMC... 2 1.1 PRODUCTS... 3 1.2 TURN KEY MIL STD 461 TEST INSTALLATIONS... 3 2. TEST SETUP DESCRIPTION... 4 2.1 TEST

More information

Electricity Meter Test System

Electricity Meter Test System Component Tests Electricity Meter Test System System Overview.................... 3 Features & Benefits................... 4 Standards....................... 6 Application Options................... 7

More information

Technical Specification

Technical Specification LARGEST RANGE OF IMPULSE TESTERS UP TO 100KV/100KA Technical Specification No. E-MIG0603IN2.doc revised: 20.October 2004 1 MIG Tester Type MIG0603IN2 1 MIG Tester Type MIG0603IN2 1 1.1 Introduction 1 2

More information

Power quality report. A Manufacturing Plant

Power quality report. A Manufacturing Plant Power quality report Prepared for A Manufacturing Plant 6 May 2016 by Dr Angelo De Francesco Power Quality Consultant Page 1 Contents 1 EXECUTIVE SUMMARY... 4 2 INTRODUCTION... 5 2.1 SITE MONITORED...

More information

Appendix A: Specifications

Appendix A: Specifications Established 1981 Advanced Test Equipment Rentals www.atecorp.com 800-404-ATEC (2832) Appendix A: Specifications This section provides a complete description of the video measurement set specifications.

More information

Immunity Test System RIS 3000 / RIS 6000 acc. to IEC/EN

Immunity Test System RIS 3000 / RIS 6000 acc. to IEC/EN Description The setup of a radiated immunity test system can be done in the conventional way with many separate instruments or in a more comfortable and less risky way with our new EMC control unit, type

More information

Agilent Technologies 8114A 100 V/2 A Programmable Pulse Generator

Agilent Technologies 8114A 100 V/2 A Programmable Pulse Generator Agilent Technologies 8114A 10/2 A Programmable Pulse Generator Technical Specifications Faster Characterization and Test, without Compromise Key Features: 10pp (2 A) into open (or from 1KW into 50W), 7ns

More information

ANCOM s Laboratory for Electromagnetic Compatibility and Radio Equipment Testing

ANCOM s Laboratory for Electromagnetic Compatibility and Radio Equipment Testing ANCOM s Laboratory for Electromagnetic Compatibility and Radio Equipment Testing My name is Adrian Bădulescu and I have coordinated most of the activities regarding the construction, equipping and implementation

More information

ESD Test System. Immunity Tests

ESD Test System. Immunity Tests Immunity Tests ESD Test System Overview of Phenomena 3 Features & Benefits 4 Applications 6 Technical Specifications 8 Accessories and Options 12 Software 14 EMC PARTNER s Product Range 15 Immunity Tests:

More information

MIL Standard 461 G. final release December 11 th, EMC PARTNER - Largest range of impulse test equipment up to 100kV and 100kA

MIL Standard 461 G. final release December 11 th, EMC PARTNER - Largest range of impulse test equipment up to 100kV and 100kA MIL Standard 461 G final release December 11 th, 2015 EMC PARTNER - Largest range of impulse test equipment up to 100kV and 100kA CDN-UTP8 Ed. 3 - Universal The Swiss CDN company for data EMC and telecom

More information

DRTS 66 The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters

DRTS 66 The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters Testing all relay technologies: electromechanical, solid state, numerical and IEC61850 Manual

More information

Southern Company Power Quality Policy

Southern Company Power Quality Policy Southern Company Power Quality Policy Alabama Power Georgia Power Gulf Power Mississippi Power i Table of Contents: Southern Company Power Quality Policy SCOPE AND PURPOSE... 1 DEFINITIONS... 2 I. HARMONICS...

More information

Coils Loop sensors / radiating loops / Helmholtz coils

Coils Loop sensors / radiating loops / Helmholtz coils Coils Loop sensors / radiating loops / Helmholtz coils Loop sensors / radiating loops: page 2 Helmholtz coils: page 6 Coils_F - 44/05 Page 1 of 10 Coils according to MIL-STD-461E Loop sensor / radiating

More information

Specification for a Fully Automatic Meter Test Equipment for testing Three-phase/Single/Transformer operated/ reference Standard energy meters.

Specification for a Fully Automatic Meter Test Equipment for testing Three-phase/Single/Transformer operated/ reference Standard energy meters. Specification for a Fully Automatic Meter Test Equipment for testing Three-phase/Single/Transformer operated/ reference Standard energy meters. Scope: This specification defines the requirement of a Three

More information

AC Power Sources. Newtons4th Ltd

AC Power Sources. Newtons4th Ltd N4L Newtons4th Ltd AC Power Sources Compliant Testing In Accordance with: IEC/EN61000-3-2 IEC/EN61000-3-3 IEC/EN61000-3-11 IEC/EN61000-3-12 N4A DC+AC Power Sources - 3kVA Single Phase - 6kVA Single Phase

More information

ETSI EN V1.2.1 ( )

ETSI EN V1.2.1 ( ) EN 300 132-3 V1.2.1 (2003-08) European Standard (Telecommunications series) Environmental Engineering (EE); Power supply interface at the input to telecommunications equipment; Part 3: Operated by rectified

More information

The Fluke 6100A. Electrical Power Standard. The most accurate, comprehensive and flexible source of electrical power signals

The Fluke 6100A. Electrical Power Standard. The most accurate, comprehensive and flexible source of electrical power signals The Fluke 6100A Electrical Power Standard The most accurate, comprehensive and flexible source of electrical power signals Measurement validation for electrical power applications The importance of accurate

More information

IEC Electrical fast transient / Burst immunity test

IEC Electrical fast transient / Burst immunity test CONDUCTED RF EQUIPMENT POWER AMPLIFIERS IEC 61000-4-4 Electrical fast transient / Burst immunity test IEC 61000-4-4 Electrical fast transient / Burst immunity test Markus Fuhrer Phenomenom open a contact

More information

PRODUCT DATA. Sound Intensity Calibrator Type Uses and Features

PRODUCT DATA. Sound Intensity Calibrator Type Uses and Features PRODUCT DATA Sound Intensity Calibrator Type 4297 Sound Intensity Calibrator Type 4297 is used for on site sound pressure calibration and pressure residual intensity index verification. Its most important

More information

The Fluke 6105A and 6100B Electrical Power Standards

The Fluke 6105A and 6100B Electrical Power Standards The Fluke 6105A and 6100B Electrical Power Standards The most accurate, comprehensive and flexible sources of electrical power quality and energy signals Measurement validation for electrical power quality

More information

Models 31120/31120A/31180/31180A Programmable AC Power Source

Models 31120/31120A/31180/31180A Programmable AC Power Source FEATURES: Power Rating: 31120/31120A: 12KVA 31180/31180A: 18KVA Voltage : 0-150V/0-300V/Auto Frequency: DC, 15Hz - 1500Hz 1-phase or 3-phase output selectable Programmable slew rate setting for changing

More information

EMC Test Report. Report Number: M030826

EMC Test Report. Report Number: M030826 Page 1 of 36 EMC Technologies Pty Ltd ABN 82 057 105 549 57 Assembly Drive Tullamarine Victoria Australia 3043 Ph: + 613 9335 3333 Fax: + 613 9338 9260 email: melb@emctech.com.au EMC Test Report Report

More information

PROGRAMMABLE AC POWER SOURCE

PROGRAMMABLE AC POWER SOURCE Ihr Spezialist für Mess- und Prüfgeräte Programmable AC Power Source MODEL 61500 SERIES Key Features: PROGRAMMABLE AC POWER SOURCE MODEL 61500 SERIES Chroma AC power source 61500 series sets up waveform

More information

EMC standards. Presented by: Karim Loukil & Kaïs Siala

EMC standards. Presented by: Karim Loukil & Kaïs Siala Training Course on Conformity and Interoperability on Type Approval testing for Mobile Terminals, Homologation Procedures and Market Surveillance, Tunis-Tunisia, from 20 to 24 April 2015 EMC standards

More information

A Study of Conducted-Emission Stable Source Applied to the EMC US and EU Standards

A Study of Conducted-Emission Stable Source Applied to the EMC US and EU Standards Fourth LACCEI International Latin American and Caribbean Conference for Engineering and Technology (LACCEI 2006) Breaking Frontiers and Barriers in Engineering: Education, Research and Practice, 21-23

More information

Accr. 002-Test EN-ISO (2005)

Accr. 002-Test EN-ISO (2005) Electromagnetic compatibility LAB > Examination of compliance with EMC standards > Measurement of radio-disturbances > Immunity tests > 2004/108/EC EMC Directive > CE Marking > Measurement of electromagnetic

More information

Voltage Transient Emission Test

Voltage Transient Emission Test Manual For Operation AN 200 Series Voltage Transient Emission Test AN 200 AN 200B The AN 200 is used to evaluate automotive electrical and electronic components for conducted emissions of transients along

More information

AC3000 INTELLIGENT BROADBAND AMPLIFIER

AC3000 INTELLIGENT BROADBAND AMPLIFIER Kari Mäki 24.9.2012 1(7) AC3000 INTELLIGENT BROADBAND AMPLIFIER AC3000, the most advanced amplifier on the market, is the latest leading-edge addition to AC family with extended frequency and gain ranges

More information

Model 61511/61512/61611/61612

Model 61511/61512/61611/61612 Programmble AC Power Source Key Features: Programmable AC Power Source Model 61511/61512/61611/61612 The global market for AC power testing demands for more sophisticated, high performance AC power source

More information

EMC TEST REPORT. For. Switching Mode Power Adaptor. Model No.: 9W/14.4V/EU(18V/1.0A), 19W/14.4V/EU(12V/1.5A)

EMC TEST REPORT. For. Switching Mode Power Adaptor. Model No.: 9W/14.4V/EU(18V/1.0A), 19W/14.4V/EU(12V/1.5A) EMC TEST REPORT For Company Limited Liability «Faraday Electronics» Switching Mode Power Adaptor Model No.: 9W/14.4V/EU(18V/1.0A), 19W/14.4V/EU(12V/1.5A) Prepared For : Company Limited Liability «Faraday

More information

PRODUCT DATA. Sound Intensity Calibrator Type 4297

PRODUCT DATA. Sound Intensity Calibrator Type 4297 PRODUCT DATA Sound Intensity Calibrator Type 4297 Sound Intensity Calibrator Type 4297 is used for on-site sound-pressure calibration and pressure-residual intensity-index verification. Its most important

More information

National Standard of The People s Republic of China

National Standard of The People s Republic of China Translated English of Chinese Standard: GB/T17626.11-2008 Translated by: www.chinesestandard.net Wayne Zheng et al. Email: Sales@ChineseStandard.net ICS 33.100.20 L 06 GB National Standard of The People

More information

ACE3 INTELLIGENT BROADBAND AMPLIFIER

ACE3 INTELLIGENT BROADBAND AMPLIFIER 12.4.2017 1(8) ACE3 INTELLIGENT BROADBAND AMPLIFIER Features ACE3 is the most advanced compact amplifier on the market. It has 1.2 GHz frequency range and integrated electrical controls in both up- and

More information

Power Quality Measurements the Importance of Traceable Calibration

Power Quality Measurements the Importance of Traceable Calibration Power Quality Measurements the Importance of Traceable Calibration H.E. van den Brom and D. Hoogenboom VSL Dutch Metrology Institute, Delft, the Netherlands, hvdbrom@vsl.nl Summary: Standardization has

More information

Power Quality Report. A Manufacturing Plant

Power Quality Report. A Manufacturing Plant Power Quality Report Prepared for A Manufacturing Plant 6 May 2016 by Dr Angelo De Francesco Power Quality Consultant CHK Power Quality Pty Ltd Page 1 Contents 1 EXECUTIVE SUMMARY... 4 2 INTRODUCTION...

More information

The series allows users to compose. amplify the analog signal from arbitrary signal generator. Thus, it is capable of simulating the

The series allows users to compose. amplify the analog signal from arbitrary signal generator. Thus, it is capable of simulating the Programmable AC Power Source MODEL 61500 SERIES Key Features: PROGRAMMABLE AC POWER SOURCE MODEL 61500 SERIES Chroma AC power source 61500 series sets waveform as well as measurements such as up the new

More information

2620 Modular Measurement and Control System

2620 Modular Measurement and Control System European Union (EU) Council Directive 89/336/EEC Electromagnetic Compatibility (EMC) Test Report 2620 Modular Measurement and Control System Sensoray March 31, 2006 April 4, 2006 Tests Conducted by: ElectroMagnetic

More information

EMC test report AU01+E04

EMC test report AU01+E04 Customer: Altuflevskoye shosse,h.48,bld.1pr.1,room39 Moscow,127566 Russia EMC test report 130504-AU01+E04 This test report may not be copied or published in a part without the written authorization of

More information

CBA 400M MHZ to 400 MHZ

CBA 400M MHZ to 400 MHZ 1 CBA 400M-100 1 MHZ to 400 MHZ 100 watt amplifier user Manual 601-298A CBA 400M-100 1 MHZ to 400 MHZ 100 watt amplifier USER Manual CBA 400M-100 User Manual contents 1 Safety information 5 2 Introduction

More information

PQ-Box 100 Network Analyzer for Low-, Medium- and High-Voltage Networks

PQ-Box 100 Network Analyzer for Low-, Medium- and High-Voltage Networks GB Technical data Issue 06/2009 PQ-Box 100 Network Analyzer for Low-, Medium- and High-Voltage Networks Fault detection Evaluation of voltage quality according to EN50160 and IEC61000-2-2 Fault recorder

More information

AC3200 INTELLIGENT BROADBAND AMPLIFIER

AC3200 INTELLIGENT BROADBAND AMPLIFIER Kari Mäki 7.4.2015 1(7) AC3200 INTELLIGENT BROADBAND AMPLIFIER AC3200 is the latest leading-edge addition to AC family with extended frequency and gain ranges and integrated electrical controls in both

More information

Datasheet SHF D Synthesized Clock Generator

Datasheet SHF D Synthesized Clock Generator SHF Communication Technologies AG Wilhelm-von-Siemens-Str. 23D 12277 Berlin Germany Phone +49 30 772051-0 Fax +49 30 7531078 E-Mail: sales@shf.de Web: http://www.shf.de Datasheet SHF 78210 D Synthesized

More information

Darkglass Suite. Disclaimer

Darkglass Suite. Disclaimer USER MANUAL Darkglass Suite Download the free Darkglass Suite software from www.darkglass.com/suite to configure the pedal, load new impulses and download firmware updates. Darkglass Suite comes with a

More information

How will the third edition of IEC affect your test facility?

How will the third edition of IEC affect your test facility? How will the third edition of IEC 61000-4-3 affect your test facility? Changes in the standard could mean that your amplifier is no longer powerful enough Introduction The third edition of IEC 61000-4-3

More information

Model Hz to 10MHz Precision Phasemeter. Operating Manual

Model Hz to 10MHz Precision Phasemeter. Operating Manual Model 6610 1Hz to 10MHz Precision Phasemeter Operating Manual Service and Warranty Krohn-Hite Instruments are designed and manufactured in accordance with sound engineering practices and should give long

More information

R&S ZV-Z5x Calibration Units Specifications

R&S ZV-Z5x Calibration Units Specifications R&S ZV-Z5x Calibration Units Specifications Test & Measurement Data Sheet 09.01 Specifications apply under the following conditions: Sufficient warm-up time (approx. 15 minutes) at ambient temperature,

More information

Technical Specification

Technical Specification LARGEST RANGE OF IMPULSE TESTERS UP TO 100KV/100KA Technical Specification E-MIG1203CWG revised: 22. June 2003 1 MIG Tester Type MIG1203CWG 1 MIG Tester Type MIG1203CWG 1 1.1 Introduction 1 2 General 2

More information

INTRODUCTION TO CONDUCTED EMISSION

INTRODUCTION TO CONDUCTED EMISSION IEEE EMC Chapter - Hong Kong Section EMC Seminar Series - All about EMC Testing and Measurement Seminar 2 INTRODUCTION TO CONDUCTED EMISSION By Duncan FUNG 18 April 2015 TOPICS TO BE COVERED Background

More information

EN 55022: 2010+AC:2011 Clause 6.1 Pass. Harmonic Current EN :2006+A1:2009+A2:2009 Class A N/A

EN 55022: 2010+AC:2011 Clause 6.1 Pass. Harmonic Current EN :2006+A1:2009+A2:2009 Class A N/A Reference No.: WT12106773-N-S-E Page 2 of 33 1 Test Summary Test Item Mains Terminal Disturbance Voltage, 150KHz to 30MHz Radiation Emission, 30MHz to 1000MHz EMISSION Test Standard Class / Severity Result

More information

AC+DC Power Sources. Newtons4th Ltd. N4A06-6kVA Single Phase N4A18-18kVA Three Phase N4A30-30kVA Three Phase Higher Power Systems also Available

AC+DC Power Sources. Newtons4th Ltd. N4A06-6kVA Single Phase N4A18-18kVA Three Phase N4A30-30kVA Three Phase Higher Power Systems also Available N4L Newtons4th Ltd AC+DC Power Sources Compliant Testing In Accordance with: IEC/EN61000-3-2 IEC/EN61000-3-3 IEC/EN61000-3-11 N4A06-6kVA Single Phase N4A18-18kVA Three Phase - 30kVA Three Phase Higher

More information

R&S ZV-Z5x Calibration Units Specifications

R&S ZV-Z5x Calibration Units Specifications R&S ZV-Z5x Calibration Units Specifications Test & Measurement Data Sheet 10.00 Specifications apply under the following conditions: Sufficient warm-up time (approx. 15 minutes) at ambient temperature,

More information

Transducer for Measurement Bridges SCM90, SIGS15

Transducer for Measurement Bridges SCM90, SIGS15 Transducer for Measurement Bridges SCM90, SIGS15 General Description Transducer for measurement bridges for DINrails and for printed circuit boards. Programmable ranges and bridge supply, voltage or current

More information

P331-2 set ESD generator (IEC )

P331-2 set ESD generator (IEC ) User manual Probe set set ESD generator (IEC 61000-4-2) Copyright January 2017 LANGER GmbH 2017.01.09 User manual Table of contents: Page 1 ESD generator (IEC 61000-4-2) 3 1.1 Design and function of the

More information

shunt (parallel series

shunt (parallel series Active filters Active filters are typically used with diode/thyristor rectifiers, electric arc furnaces, etc. Their use in electric power utilities, industry, office buildings, water supply utilities,

More information

EN61326 EMC COMPLIANCE REPORT on the LP Series Ultrasonic Transmitter Remote Amplifier and Transducer for Hawk Measurement Systems Pty Ltd

EN61326 EMC COMPLIANCE REPORT on the LP Series Ultrasonic Transmitter Remote Amplifier and Transducer for Hawk Measurement Systems Pty Ltd Page 1 of 15 EMC Technologies Pty Ltd ABN 82 057 105 549 57 Assembly Drive Tullamarine Victoria Australia 3043 Ph: + 613 9335 3333 Fax: + 613 9338 9260 email: melb@emctech.com.au EN61326 EMC COMPLIANCE

More information

Darkglass Suite. Disclaimer

Darkglass Suite. Disclaimer USER MANUAL Darkglass Suite Download the free Darkglass Suite software from www.darkglass.com/suite to configure the pedal, load new impulses and download firmware updates. Darkglass Suite comes with a

More information

Page 1 of 28. Ingo Röhr. Frank Hesmer

Page 1 of 28. Ingo Röhr. Frank Hesmer Page 1 of 28 TEST REPORT Engineering recommendation G83/1 Recommendation for the connection of small-scale embedded generators (up to 16 A per phase) in parallel with public low-voltage distribution networks.

More information

EMI T E S T R E P O R T

EMI T E S T R E P O R T EMI T E S T R E P O R T - FCC Part 15B - Test Report No. : T38935-00-02TK 27. November 2014 Date of issue Type / Model Name : One Touch Select Plus Flex Product Description : Blood glucose meter with Bluetooth

More information

ARE HARMONICS STILL A PROBLEM IN DATA CENTERS? by Mohammad Al Rawashdeh, Lead Consultant, Data Center Engineering Services

ARE HARMONICS STILL A PROBLEM IN DATA CENTERS? by Mohammad Al Rawashdeh, Lead Consultant, Data Center Engineering Services ARE HARMONICS STILL A PROBLEM IN DATA CENTERS? by Mohammad Al Rawashdeh, Lead Consultant, Data Center Engineering Services edarat group INTRODUCTION Harmonics are a mathematical way of describing distortion

More information

CHROMA ATE INC. Programmable AC Source 61500/61600 Series. Product Manager: Galen Chou

CHROMA ATE INC. Programmable AC Source 61500/61600 Series. Product Manager: Galen Chou CHROMA ATE INC. Programmable AC Source 61500/61600 Series Product Manager: Galen Chou Chroma AC Source Family Outline 1. What is programmable AC source? 2. What is user s need? 3. What do they test with

More information

2.1 Performance Standards The UPS is designed with the applicable sections of UL, CUL, and ISO The UPS has UL and CUL listing.

2.1 Performance Standards The UPS is designed with the applicable sections of UL, CUL, and ISO The UPS has UL and CUL listing. 1.0 Scope This document describes the specification for Toshiba 1000 Series On-Line Uninterruptible Power System (UPS). The UPS will supply a computer grade AC output sine wave which is unaffected by the

More information

BRIDGEABLE FOUR-CHANNEL POWER AMPLIFIER GM-A6604 GM-A4604. Owner s Manual

BRIDGEABLE FOUR-CHANNEL POWER AMPLIFIER GM-A6604 GM-A4604. Owner s Manual BRIDGEABLE FOUR-CHANNEL POWER AMPLIFIER GM-A6604 GM-A4604 Owner s Manual Section 01 Before you start Thank you for purchasing this PIONEER product To ensure proper use, please read through this manual

More information

Applications. Other applications include:

Applications. Other applications include: California Instruments CSW Series High Performance Programmable AC and DC Power Source Combination AC and DC Power Source 2Hz-7,990Hz Output Frequencies Arbitrary and Harmonic Waveform Generation Built-In

More information

The series allows users to compose. amplify the analog signal from arbitrary signal generator. Thus, it is capable of simulating the

The series allows users to compose. amplify the analog signal from arbitrary signal generator. Thus, it is capable of simulating the Programmable AC Power Source MODEL 61500 SERIES Key Features: PROGRAMMABLE AC POWER SOURCE MODEL 61500 SERIES Chroma AC power source 61500 series sets waveform as well as measurements such as up the new

More information

AC GHZ INTELLIGENT BROADBAND AMPLIFIER

AC GHZ INTELLIGENT BROADBAND AMPLIFIER 13.4.2016 1(8) AC3210 1.2 GHZ INTELLIGENT BROADBAND AMPLIFIER Features The AC3210 is a dual active output amplifier with 48 maximum. The amplifier stages are based on extreme high performance GaN solution

More information

Certificate of Test AND KEEPS ALL REQUIREMENTS ACCORDING THE FOLLOWING REGULATIONS IEC :2001 IEC :2007

Certificate of Test AND KEEPS ALL REQUIREMENTS ACCORDING THE FOLLOWING REGULATIONS IEC :2001 IEC :2007 Certificate of Test WE HEREBY CERTIFY THAT: Certificate No.: R07122709E Yuan Hsun Electric Co., Ltd. No. 57, Chung He Rd, Zuo-Ying Dist., Kaohsiung City 813, Taiwan R.O.C. Quad photobeam detector Quad-200CS

More information

Network Analyzer for Low-, Medium- and High-Voltage Networks

Network Analyzer for Low-, Medium- and High-Voltage Networks Technical data Network nalyzer for Low-, Medium- and High-Voltage Networks Model PQ-Box 150 1 Fault detection 1 Evaluation of voltage quality according to EN50160 and IEC61000-2-2 (2-4) 1 FFT nalysis up

More information

Electronic AC Load ZSAC Series. 400 W up to 21,000 W 260 V up to 440 V 3 A up to 100 A. Rev. 3.03

Electronic AC Load ZSAC Series. 400 W up to 21,000 W 260 V up to 440 V 3 A up to 100 A. Rev. 3.03 Electronic AC Load Series 400 W up to 21,000 W 260 V up to 440 V 3 A up to 100 A Rev. 3.03 Electronic AC Loads, Series Interface overview RS-232 USB GPIB LAN System bus Analog / Analog isolated X X Standard

More information

INTERNATIONAL TELECOMMUNICATION UNION SERIES K: PROTECTION AGAINST INTERFERENCE

INTERNATIONAL TELECOMMUNICATION UNION SERIES K: PROTECTION AGAINST INTERFERENCE INTERNATIONAL TELECOMMUNICATION UNION ITU-T K.42 TELECOMMUNICATION STANDARDIZATION SECTOR OF ITU (05/98) SERIES K: PROTECTION AGAINST INTERFERENCE Preparation of emission and immunity requirements for

More information

TECHNICAL REQUIREMENTS FOR ELECTROMAGNETIC DISTURBANCES EMITTED FROM LIGHTING EQUIPMENT INSTALLED IN TELECOMMUNICATION CENTERS

TECHNICAL REQUIREMENTS FOR ELECTROMAGNETIC DISTURBANCES EMITTED FROM LIGHTING EQUIPMENT INSTALLED IN TELECOMMUNICATION CENTERS TR550004 TECHNICAL REQUIREMENTS FOR ELECTROMAGNETIC DISTURBANCES EMITTED FROM LIGHTING EQUIPMENT INSTALLED IN TELECOMMUNICATION CENTERS TR NO. 174001 EDITION 2.1 September 3 rd, 2018 Nippon Telegraph and

More information

EMC VERIFICATION SUMMARY Report No.: SZHH

EMC VERIFICATION SUMMARY Report No.: SZHH EMC VERIFICATION SUMMARY Toy ITE Others Additional Models: 0801 to 0899 INCLUSIVE, 0804, 0804W, 0805, 0806, 0807, 0808, 0809, 0811, 0811W, 0812, 0813, 0814,0815, 0816, 0817,0817 ROOM 619, 6/F. PENINSULA

More information

Model 4007DDS. 7 MHz Sweep Function Generator

Model 4007DDS. 7 MHz Sweep Function Generator Model 4007DDS 7 MHz Sweep Function Generator 1 Model 4007DDS - Instruction Manual Limited Two-Year Warranty B&K Precision warrants to the original purchaser that its products and the component parts thereof,

More information

COUPLING / DECOUPLING NETWORK (CDN) CDN AF TYPE, CDN CAN

COUPLING / DECOUPLING NETWORK (CDN) CDN AF TYPE, CDN CAN IEC / EN 61000-4-6 specifies the design and performance of a range of coupling / decoupling networks (CDNs). Each CDN is specific to the of cable and the intended signal carried on the cable. Teseq offers

More information

These medical power supplies are ideal for monitoring, home health equipment as well as surgical devices.

These medical power supplies are ideal for monitoring, home health equipment as well as surgical devices. The ABC450 Series of open-frame power supplies, with its wide universal 90-264 VAC input range and high power density, is available at 450 W of output power and a variety of single and multiple output

More information

Saturation of Active Loop Antennas

Saturation of Active Loop Antennas Saturation of Active Loop Antennas Alexander Kriz EMC and Optics Seibersdorf Laboratories 2444 Seibersdorf, Austria Abstract The EMC community is working towards shorter test distances for radiated emission

More information

ETSI TS V4.0.0 ( )

ETSI TS V4.0.0 ( ) TS 151 026 V4.0.0 (2002-01) Technical Specification Digital cellular telecommunications system (Phase 2+); GSM Repeater Equipment Specification (3GPP TS 51.026 version 4.0.0 Release 4) GLOBAL SYSTEM FOR

More information

120/240 Watt AC-DC Front End with PFC W Series Convert Select 120 Convert Select 240

120/240 Watt AC-DC Front End with PFC W Series Convert Select 120 Convert Select 240 Industrial Environment AC-DC Converters >100 Watt W Series 120/240 Watt AC-DC Front End with PFC W Series Convert Select 120 Convert Select 240 Rugged 35 mm DIN-rail snap-fit design 3000 V AC input to

More information

201AP Charge Amplifier User Manual

201AP Charge Amplifier User Manual Trig-Tek 201AP Charge Amplifier User Manual Publication No. 980996 Rev. A Astronics Test Systems Inc. 4 Goodyear, Irvine, CA 92618 Tel: (800) 722-2528, (949) 859-8999; Fax: (949) 859-7139 atsinfo@astronics.com

More information

B9000 FXS kVA B9600 FXS kVA

B9000 FXS kVA B9600 FXS kVA OF CONTINUOUS SERVICE YEARS WARRANTY B9000 FXS 60-300kVA B9600 FXS 400-800kVA BORRI B9000 FXS B9600 FXS With disturbances to the electrical supply being one of the major causes of IT downtime, the UPS

More information

Coupling / decoupling network (CDN) for screened or coaxial cables

Coupling / decoupling network (CDN) for screened or coaxial cables IEC / EN 61000-4-6 specifies the design and performance of a range of coupling / decoupling networks (CDNs). Each CDN is specific to the type of cable and the intended signal carried on the cable. Teseq

More information