CHROMA ATE INC. Programmable AC Source 61500/61600 Series. Product Manager: Galen Chou

Size: px
Start display at page:

Download "CHROMA ATE INC. Programmable AC Source 61500/61600 Series. Product Manager: Galen Chou"

Transcription

1 CHROMA ATE INC. Programmable AC Source 61500/61600 Series Product Manager: Galen Chou

2 Chroma AC Source Family

3 Outline 1. What is programmable AC source? 2. What is user s need? 3. What do they test with AC source? 4. Functions of Chroma AC sources

4 A Primitive AC Source 1. Not easy to setup 2. Inconvenient to use 3. No protection Power Meter Function Generator Power Amplifier Transformer C C

5 AC Source Structure AC Input Input Stage Power Stage Output Stage AC Output Waveform Generator, Control and Measurement Units User Interface User

6 AC Source Power Stages Linear type, a transformer on output, high impedance Line Input A/D Power Stage D/A Power Stage AC Output A transformer on input, weight is heavy Line Input A/D Power Stage D/A Power Stage AC Output

7 Chroma s AC Source Advantage Chroma Line Input A/D Power Stage D/D Power Stage D/A Power Stage AC Output 1. No low -frequency transformer, lighter than others 2. Standard PFC input, save power and less interference to main 3. No transformer on output, low impedance

8 Chroma s AC Source Advantage Output impedance: Zo = Ro + Lo High impedance: Voltage drop, Current inhibit, High frequency current filter, not good for testing IEC The lab doesn t use the AC source with a transformer on output. Zo AC Source

9 What is users need? Basic : (61500/61600 Series) 1. Clean, pure and stable sine waveform AC power 2. Measurement : Power, voltage, current Monitor 3. Line regulation test (90 264V, 47-63Hz) 4. Simulation mains for all power systems in the world 230V/50Hz, 120V/60Hz, 100V/50Hz 5. Auto-test (Remote control)

10 What is users need? How much power of AC source dose user need? Example: Test 300W (output) power supply 1. Ask the efficiency: Input power = 300W/0.8 = 375W 2. Ask the Power Factor: Input VA = 375/0.75 = 500VA 3. Ask if test OPT: Max VA = 500VA x 1.3 = 650VA 4. Ask the low line : Max input current : 650VA/90V = 7.22A At least, the customer needs 61502/61602 (1KW) 5. Ask the inrush current: If 45Apeak is needed at 230V, then he needs 61504/61604 (2KW)

11 What is users need? Additional : (61500/61600 series) 1. Power Turn ON/OFF phase angle Setting 90 Turn ON for inrush current test. 2. Inrush Current Measurement (Delay time, Interval) 3. Voltage/Frequency Slew Rate Setting a. Operate for range scanning (90V-264V 或 47H 63Hz ) b. Raising the voltage gradually, power on UUT with less inrush current 4. Voltage/Frequency Save and Recall ( One-key Recall)

12 61500/61600 Softpanel Function Auto Run: Programming for long time test (On/Off or Burn-in)

13 61500/61600 Softpanel Function Report Function : Data Recording stored in a File

14 What else is users need? Only testing the specification of input power is not enough to verify the UUT. Simulating the power like real world is the way to get better quality and stability. Advance Test : (61500 series only) 1. Transient Voltage Simulation 2. Distorted Waveform Simulation

15 Transient Output Different kind of transient output: Surge Sag Frequency Variation Cycle Dropout

16 Influence of Transient Output Example : Power supply of DVD player +5V to memory +3.3V to CPU +12V to driver When cycle dropout occurs, output voltage will drop then back to normal level. The machine might shut down because of improper dropping rate of voltage. (Memory might be reset, but CPU might work as usual. )

17 Example for Transient Output Test Cycle Drop Out Test Brown Out Test

18 Regulation for Transient Output IEC : Voltage dips, short interruptions and voltage variation immunity tests dip short 100%UT voltage variation 40%UT 0%UT t (sec)

19 Regulation for Transient Output IEC : Voltage fluctuation immunity test Un 60s Un + 10%Un 60s 60s Un - 10%Un 60s 5s±0.5s ΔU 5 periods 2s±0.2s 5 periods

20 Regulation for Transient Output IEC : Variation of power frequency immunity test f1+δf 120s f1 tp tp 60s 60s tp tp f1 120s f1-δf f1 tp f1+δf

21 61500 AC Source Functions for Transient Output LIST Mode: Program output waveform sequence by sequence

22 61500 AC Source Functions for Transient Output PULSE Mode: Insert a waveform into normal voltage

23 61500 AC Source Functions for Transient Output STEP Mode : Change from an initial voltage to destination step by step

24 Transient Output with High Voltage A transient high voltage of main will damage the electrical products. (It happens usually in China and India.) Many companies have asked it as a standard test item. Chroma solution: Model 6560, or 2 units connecting in series. 220V 400V/0.5sec

25 Transient Output with High Voltage 2 units of AC Source with synchronizing signal: Use 3-phase Mode, 61500/61600 as the Master, as the Slave. Master: Fixed Mode 220V L 220V with 400V/0.5s transient N L Slave: List Mode 180V/0.5 sec L N UUT N

26 2 Units of AC Source Application The voltage resonance happens when EMI filter plugs into the main. Using AC Source to simulate the disturbance effect.

27 Combine 3 Units of AC Sources Chroma 61500/61600 AC Source : 3 units can be combined to a 3-phase AC Power Source (1 Master, 2 Slave units with setting the phase 120 and 240 )

28 Distorted Waveform Power Plant Power Network Nonlinear load pollutes the mains with distortion current. Pure V Io Distorted V Zo L C Resonance Point Frequency Fr = 1 2Π LC

29 Distorted Waveform Different kind of distorted waveform: Harmonic Distortion Interharmonic Distortion Clipped Sine Waveform Low frequency drift

30 Regulation for Distorted Waveform IEC : Harmonics, Interharmonics including mains signaling at AC power port immunity tests Flat Curve Sweep Over Swing

31 Influence of Distorted Waveform Comparing With/Without harmonic component: Same UUT, 2.46A 3.015A, 22% increase

32 Influence of Distorted Waveform Comparing With/Without interharmonic component: Same UUT, 0.83A 1.3A, 57% increase

33 Influence of Distorted Waveform With voltage interharmonics component: Fi=30.85Hz, level =7% abnormal current waveform PWM unstable

34 61500 s Functions for Distorted Waveform SYNTHESIS : Edit harmonic components (Amplitude & Phase) of 40 orders to synthesize a new waveform. (50/60Hz)

35 61500 s Functions for Distorted Waveform INTERHARMONICS : Add a sweeping frequency component (0.01Hz 2400 Hz) on a normal voltage. It helps to find the resonance point, or the weak point of the UUT.

36 61500 s Functions for Distorted Waveform WAVEFORM EDITOR : Edit waveform by harmonic orders on softpanel, send the data and save to User Waveform of AC Source. It can be used on every frequency but less accuracy.

37 Application for AC Power Distortion With the customers or facilities being oversea, the input power problem can t be solved in a short time. Solution: 1. Measure the harmonic components by Power Analyzer on facility. 2. Re-build the waveform by SYNTHESIS function of AC Source, RD or QC can test it on the lab..

38 Application for AC Power Distortion Measure Harmonic components Re-build Waveform

39 DC Component of AC Power It contains DC component on some AC power sources, like UPS. 1. Current unbalance. Input rectifier may be damaged. 2. Input transformer saturation (DC current) Using AC Source AC+DC mode to simulate. Without DC component With DC component

40 DC Output Application of AC Power Use optional unit A615008, DC Noise Filter, when output DC voltage. It can help to decrease the noise, and increase the stability. Connection Method:

41 Analog Control for AC Source 1. DC Level Control Mode: Use an external DC voltage to control the amplitude of output AC voltage. Frequency is set on AC Source. 10Vdc External input V Output V 424Vdc 212Vdc 300V rang 150V rang

42 Analog Control for AC Source 2. AC Amplifier Mode: Send an external signal to AC source and amplify it as the output waveform, just like the user s need. External input V Output V 10 Vdc 424 rang 212 rang -10 Vdc -424 rang -212 rang

43 TTL signals of AC Source 1. AC_ON : Up to high level when AC source output. Counting time interval between power-on and normal operation. 2. Synchronize (Transient) : Send a pulse signal when output change. For external trigger or system integration

44 TTL signals of AC Source 3. Fault : TTL level becomes low when protection occur. For notice or system integration 4. Remote_Inhibit : Inhibit the output when the signal becomes low. External control for system integration. Trigger Live

45 Regulation Test AC Source offers a pure and stable voltage to UUT. EN Limits for harmonic current emissions EN Limitation of voltage fluctuations and flicker Haefely use Chroma AC source as a standard source.

46 Do you have Questions? For more information on the Chroma / Series AC Power Sources or if you would like to purchase one of these models please contact your sales engineer at ValueTronics or

The series allows users to compose. amplify the analog signal from arbitrary signal generator. Thus, it is capable of simulating the

The series allows users to compose. amplify the analog signal from arbitrary signal generator. Thus, it is capable of simulating the Programmable AC Power Source MODEL 61500 SERIES Key Features: PROGRAMMABLE AC POWER SOURCE MODEL 61500 SERIES Chroma AC power source 61500 series sets waveform as well as measurements such as up the new

More information

PROGRAMMABLE AC POWER SOURCE

PROGRAMMABLE AC POWER SOURCE Ihr Spezialist für Mess- und Prüfgeräte Programmable AC Power Source MODEL 61500 SERIES Key Features: PROGRAMMABLE AC POWER SOURCE MODEL 61500 SERIES Chroma AC power source 61500 series sets up waveform

More information

The series allows users to compose. amplify the analog signal from arbitrary signal generator. Thus, it is capable of simulating the

The series allows users to compose. amplify the analog signal from arbitrary signal generator. Thus, it is capable of simulating the Programmable AC Power Source MODEL 61500 SERIES Key Features: PROGRAMMABLE AC POWER SOURCE MODEL 61500 SERIES Chroma AC power source 61500 series sets waveform as well as measurements such as up the new

More information

PROGRAMMABLE AC POWER SOURCE MODEL 6500 SERIES MODEL 6500 SERIES. Programmable AC Power Source. Key Features:

PROGRAMMABLE AC POWER SOURCE MODEL 6500 SERIES MODEL 6500 SERIES. Programmable AC Power Source. Key Features: Programmable AC Power Source MODEL 6500 SERIES Key Features: PROGRAMMABLE AC POWER SOURCE MODEL 6500 SERIES The global AC power testing requirements demand more sophisticated AC Power Source that is capable

More information

Model 61511/61512/61611/61612

Model 61511/61512/61611/61612 Programmble AC Power Source Key Features: Programmable AC Power Source Model 61511/61512/61611/61612 The global market for AC power testing demands for more sophisticated, high performance AC power source

More information

PROGRAMMABLE AC POWER SOURCE MODEL 61509/61508/61507/ 61609/61608/61607 MODEL 61509/61508/61507/61609/61608/61607

PROGRAMMABLE AC POWER SOURCE MODEL 61509/61508/61507/ 61609/61608/61607 MODEL 61509/61508/61507/61609/61608/61607 MODEL 61509/61508/61507/ 61609/61608/61607 PROGRAMMABLE AC POWER SOURCE MODEL 61509/61508/61507/ 61609/61608/61607 The global market for AC power testing demands for a more sophisticated, high performance

More information

Models 31120/31120A/31180/31180A Programmable AC Power Source

Models 31120/31120A/31180/31180A Programmable AC Power Source FEATURES: Power Rating: 31120/31120A: 12KVA 31180/31180A: 18KVA Voltage : 0-150V/0-300V/Auto Frequency: DC, 15Hz - 1500Hz 1-phase or 3-phase output selectable Programmable slew rate setting for changing

More information

PROGRAMMABLE AC POWER SOURCE MODEL 61511/61512/61611/61612

PROGRAMMABLE AC POWER SOURCE MODEL 61511/61512/61611/61612 MODEL 61511/61512 61611/61612 PROGRAMMABLE AC POWER SOURCE MODEL 61511/61512/61611/61612 The global market for AC power testing has created demand for a more sophisticated, high performance AC power source

More information

Programmable AC Power Source Model 9801

Programmable AC Power Source Model 9801 Data Sheet Programmable AC Power Source The 9801 is both a programmable AC power source and measurement tool in a compact benchtop package. This fully programmable linear AC source delivers up to 300 VA

More information

IT7600 High Power Programmable AC power supply

IT7600 High Power Programmable AC power supply IT7600 High Power Programmable AC power supply Applications Military & Aerospace Testing organizations Power electronics Home appliances New energy Scientific research & Institutions IT7600 series high

More information

Designed with self-diagnostic routine and protections

Designed with self-diagnostic routine and protections Programmable AC Power Source MODEL 6500 SERIES PROGRAMMABLE AC POWER SOURCE MODEL 6500 SERIES The global AC power testing requirements demand more sophisticated AC Power Source that is capable of simulating

More information

IT7600 High performance programmable AC power supply. mu High power APPLICATIONS. Military& Aerospace. Scientific research& Institutions

IT7600 High performance programmable AC power supply. mu High power APPLICATIONS. Military& Aerospace. Scientific research& Institutions YOUR POWER TESTING SOLUTION IT7600 High performance programmable AC power supply Home appliances Military Aerospace can e CM7u DltSi-Ofunction Hig hp New energy oerf rm AC + D hase BuAilt-in power meter

More information

SP300VAC600W Programmable AC Source

SP300VAC600W Programmable AC Source SP300VAC600W Programmable AC Source SP300VAC600W is a switching mode single-channel output high-precision programmable AC power source, which adopts high speed DSP+CPLD control, high frequency PWM power

More information

SP300VAC1500W Programmable AC Source

SP300VAC1500W Programmable AC Source SP300VAC1500W Programmable AC Source SP300VAC1500W is a switching mode single-channel output high-precision programmable AC power source, which adopts high speed DSP+CPLD control, high frequency PWM power

More information

REGENERATIVE GRID SIMULATOR MODEL SERIES MODEL SERIES. Regenerative Grid Simulator. Key Features

REGENERATIVE GRID SIMULATOR MODEL SERIES MODEL SERIES. Regenerative Grid Simulator. Key Features MODEL 61800 SERIES Key Features REGENERATIVE GRID SIMULATOR MODEL 61800 SERIES Market demand for Distributed Resource (DR) products such as PV inverters and wind energy systems is steadily growing as the

More information

Applications Avionics Testing Power Line Simulation Production Test - Power Supplies - UPS - Telecom. SMARTWAVE Programmable AC/DC Power Source

Applications Avionics Testing Power Line Simulation Production Test - Power Supplies - UPS - Telecom. SMARTWAVE Programmable AC/DC Power Source Applications Avionics Testing Power Line Simulation Production Test - Power Supplies - UPS - Telecom SMARTWAVE Programmable AC/DC Power Source PRODUCT OVERVIEW of cycles for each segment, the user can

More information

PROGRAMMABLE AC POWER SOURCE MODEL 6500 SERIES MODEL 6500 SERIES. Programmable AC Power Source. Key Features:

PROGRAMMABLE AC POWER SOURCE MODEL 6500 SERIES MODEL 6500 SERIES. Programmable AC Power Source. Key Features: Programmable AC Power Source MODEL 6500 SERIES Key Features: PROGRAMMABLE AC POWER SOURCE MODEL 6500 SERIES The global AC power testing requirements demand more sophisticated AC Power Source that is capable

More information

Software Simplifies Testing to Military and Aerospace Standards

Software Simplifies Testing to Military and Aerospace Standards Chroma Systems Solutions, Inc. Software Simplifies Testing to Military and Aerospace Standards 61500, 61600, 61700 AC Power Sources, 61500 & 61600 Soft Panel Software, and 7609-8205 Mil/Aero Soft Panel

More information

PROGRAMMABLE AC POWER SOURCE MODEL 6500 SERIES MODEL 6500 SERIES. Programmable AC Power Source. Key Features:

PROGRAMMABLE AC POWER SOURCE MODEL 6500 SERIES MODEL 6500 SERIES. Programmable AC Power Source. Key Features: Programmable AC Power Source MODEL 6500 SERIES Key Features: PROGRAMMABLE AC POWER SOURCE MODEL 6500 SERIES The global AC power testing requirements demand more sophisticated AC Power Source that is capable

More information

REGENERATIVE GRID SIMULATOR MODEL SERIES MODEL SERIES PRELIMINARY. Regenerative Grid Simulator. Key Features :

REGENERATIVE GRID SIMULATOR MODEL SERIES MODEL SERIES PRELIMINARY. Regenerative Grid Simulator. Key Features : PRELIMINARY MODEL 61800 SERIES Key Features : REGENERATIVE GRID SIMULATOR MODEL 61800 SERIES Market demand for Distributed Resource (DR) The 61800 grid simulator could also meet test products such as PV

More information

EAC/AFV-P SERIES. High performance programmable AC power source 600 VA to 5 kva only in 2 U or 5 U

EAC/AFV-P SERIES. High performance programmable AC power source 600 VA to 5 kva only in 2 U or 5 U EAC/AFV-P SERIES High performance programmable AC power source 600 VA to 5 kva only in 2 U or 5 U N ONLY 5I U 2U/ EAC/AFV-P Series General Features Output frequency up to 15 1000 Hz AC source with DC output

More information

Agilent 6800 Series AC Power Source/Analyzer

Agilent 6800 Series AC Power Source/Analyzer Agilent 6800 Series AC Power Source/Analyzer Product Note Using the Agilent Technologies 6800 Series AC Power Source/Analyzers for Generation and Measurement Applications: Simulating AC Line Sub-Cycle

More information

REGENERATIVE GRID SIMULATOR MODEL SERIES MODEL SERIES

REGENERATIVE GRID SIMULATOR MODEL SERIES MODEL SERIES MODEL 61800 SERIES REGENERATIVE GRID SIMULATOR MODEL 61800 SERIES Market demand for Distributed Resource (DR) products such as PV inverters and wind energy systems is steadily growing as the world strives

More information

Power Electronics Testing

Power Electronics Testing Power Electronics Testing PV Inverter Test Solutions www.chromaate.com Turnkey Test & Automation Solution Provider A PV system is an energy system which directly converts energy from the sunlight into

More information

EMC TEST REPORT For MPP SOLAR INC Inverter/ Charger Model Number : PIP 4048HS

EMC TEST REPORT For MPP SOLAR INC Inverter/ Charger Model Number : PIP 4048HS EMC-E20130903E EMC TEST REPORT For MPP SOLAR INC Inverter/ Charger Model Number : PIP 4048HS Prepared for : MPP SOLAR INC Address : 4F, NO. 50-1, SECTION 1, HSIN-SHENG S. RD. TAIPEI, TAIWAN Prepared by

More information

Multimeter 500CVD21 RTU500 series

Multimeter 500CVD21 RTU500 series Remote Terminal Units - Data sheet Multimeter 500CVD21 RTU500 series CT/VT interface with 4 voltage and 24 current inputs for direct monitoring of 3/4 wire 0 300 V AC (line to earth), 0...500 V AC (phase

More information

California Instruments RP Series 2000 VA V 3 45 A. General purpose AC power sources

California Instruments RP Series 2000 VA V 3 45 A. General purpose AC power sources California Instruments RP Series General purpose AC power sources Portable Power, Low Cost. 2000 VA Output Power Front and Rear Outputs 16 Hz to 5000 Hz Frequency Range High Peak Current Capability Remote

More information

Series AMEPR60-AZ up to 5A AC-DC / DC-DC LED Driver / Converter

Series AMEPR60-AZ up to 5A AC-DC / DC-DC LED Driver / Converter Click on Series name for product info on aimtec.com Series AMEPR60-AZ Models Single output FEATURES: AC-DC Constant Current or Constant Over Temperature Protection Voltage LED Driver Over Current Protection

More information

HV / MV / LV electrical network quality analyzers Class A. Communication port: local, modem, integrated Ethernet, multi-point

HV / MV / LV electrical network quality analyzers Class A. Communication port: local, modem, integrated Ethernet, multi-point 2010 MAP Range HV / MV / LV electrical network quality analyzers Class A > Network quality Analyzers PRODUCT ADVANTAGES COMPLIANT with the EN 61000-4-30 standard, Class A DETECTION of the fault LOCATION

More information

Publication Number ATFxxB Series DDS FUNCTION WAVEFORM GENERATOR. User s Guide

Publication Number ATFxxB Series DDS FUNCTION WAVEFORM GENERATOR. User s Guide Publication Number 101201 ATFxxB Series DDS FUNCTION WAVEFORM GENERATOR User s Guide Introduction This user's guide is used for all models of ATFxxB series of DDS function generator. xx in the model number

More information

Elgar SmartWave Series VA V A. High Performance AC/DC Power Source. and Boeing standards

Elgar SmartWave Series VA V A. High Performance AC/DC Power Source. and Boeing standards Elgar SmartWave Series High Performance AC/DC Power Source and Boeing standards 1750 22200 VA 156 312 V 6.5 192 A 208 230 400 230 The Elgar SmartWave (SW) Series of AC power sources offers powerful waveform

More information

AC Power Source/Analyzers...

AC Power Source/Analyzers... ... an integrated AC power solution Agilent AC Power Source/ Analyzers provide a complete AC test solution. As AC sources, they combine the capabilities of a power amplifier and an arbitrary waveform generator.

More information

DIGITAL POWER METER MODEL 66203/66204 MODEL 66203/ Digital Power Meter

DIGITAL POWER METER MODEL 66203/66204 MODEL 66203/ Digital Power Meter Digital Power Meter MODEL 6603/6604 DIGITAL POWER METER MODEL 6603/6604 Chroma 6603/6604 Power Meters are designed The 6603/6604 are packaged in a 3U high, half f o r m u l t i p l e p h a s e p o w e

More information

Roadmap For Power Quality Standards Development

Roadmap For Power Quality Standards Development Roadmap For Power Quality Standards Development IEEE Power Quality Standards Coordinating Committee Authors: David B. Vannoy, P.E., Chair Mark F. McGranghan, Vice Chair S. Mark Halpin, Vice Chair D. Daniel

More information

EMC Seminar Series All about EMC Testing and Measurement Seminar 1

EMC Seminar Series All about EMC Testing and Measurement Seminar 1 EMC Seminar Series All about EMC Testing and Measurement Seminar 1 Introduction to EMC Conducted Immunity Jeffrey Tsang Organized by : Department of Electronic Engineering 1 Basic Immunity Standards: IEC

More information

p. 1 p. 6 p. 22 p. 46 p. 58

p. 1 p. 6 p. 22 p. 46 p. 58 Comparing power factor and displacement power factor corrections based on IEEE Std. 18-2002 Harmonic problems produced from the use of adjustable speed drives in industrial plants : case study Theory for

More information

RS Pro ENGLISH. Datasheet

RS Pro ENGLISH. Datasheet Datasheet Article No: 136-5385 Digital AC Ammeter, 48x96, 1Phase, 1 or 5 Amps AC, Supply 40-300V ac/dc 136-5387 Digital AC Ammeter, 96x96, 1Phase, 1 or 5 Amps AC, Supply 40-300V ac/dc 136-5388 Digital

More information

AC POWER SOURCE CATALOG

AC POWER SOURCE CATALOG AC POWER SOURCE CATALOG THE POWER OF EXPERTISE FREQUENCY CONVERSION AEROSPACE R & D MILITARY MANUFACTURING CUSTOM COMPANY PROFILE About Pacific Power Source, Inc. Pacific Power Source has been involved

More information

Application Note. Increase Voltage Output of AC Source by paralleling two (2) or Series from 300VAC up to 600VAC.

Application Note. Increase Voltage Output of AC Source by paralleling two (2) or Series from 300VAC up to 600VAC. Application Note Product: AC Source Series: 61600 Series Date: August 27, 2008 Title: AC Source in Series Scope: Increase Voltage Output of AC Source by paralleling two (2) 61500 or 61500 Series from 300VAC

More information

Power Quality in Metering

Power Quality in Metering Power Quality in Metering Ming T. Cheng Directory of Asian Operations 10737 Lexington Drive Knoxville, TN 37932 Phone: (865) 218.5885 PQsynergy2012 www.powermetrix.com Focus of this Presentation How power

More information

1.2kV. The provides a low range error up to 0.05% and is capable of meeting the measurement uncertainty requirement of IEC 62301/EN50564.

1.2kV. The provides a low range error up to 0.05% and is capable of meeting the measurement uncertainty requirement of IEC 62301/EN50564. MODEL 66205 DIGITAL POWER METER MODEL 66205 The 66205 is the 2nd generation of the 66200 series power meter designed specifically for single channel measurement. Its state of art design is capable of providing

More information

Parallel AMX AC Power Systems

Parallel AMX AC Power Systems Parallel AMX AC Power Systems 8kVA to 30kVA 20-5,000 Hz 1Ø4 0-338VL-N 2Ø4 0-600V L-L 4 0-338V L-N /585V L-L Standard Features: Master/Slave Operation of 2 to 5 AMX AC s provides AC Power Levels to from

More information

APS-1102 Programmable AC/DC Power Source New Product Announcement

APS-1102 Programmable AC/DC Power Source New Product Announcement APS-1102 Programmable AC/DC Power Source New Product Announcement GW INSTEK is announcing a multiple function programmable AC/DC power source, APS-1 102, to the global market. The product is not only in

More information

Discontinuous Disturbance (Click) EN :2006+A1:2009+A2:2011 Clause N/A** Radiated Emission, 30MHz to 1000MHz

Discontinuous Disturbance (Click) EN :2006+A1:2009+A2:2011 Clause N/A** Radiated Emission, 30MHz to 1000MHz Reference No.: WTN13F0706038E Page 2 of 40 1 Test Summary Test Item Mains Terminal Disturbance Voltage, 148.5kHz to 30MHz Disturbance Power, 30MHz to 300MHz EMISSION Test Standard Class / Severity Result

More information

250 / 500 Vdc. Advanced Features. Performance. Reliance. Brilliance.

250 / 500 Vdc. Advanced Features. Performance. Reliance. Brilliance. California Instruments Asterion AC Series High Performance Programmable AC / DC Power Source 500 VA - 9000 VA 200 / 400 Vac 250 / 500 Vdc Advanced Features High power density in 1U chassis, up to 1.5kVA

More information

HAMEG Programmable Measuring Instruments Series 8100

HAMEG Programmable Measuring Instruments Series 8100 HAMEG Programmable Measuring Instruments Series 8100 HAMEG Programmable Measuring Instruments Series 8100 are ideally suited for test installations in production and automated tests in laboratories. They

More information

2.1 Performance Standards The UPS is designed with the applicable sections of UL, CUL, and ISO The UPS has UL and CUL listing.

2.1 Performance Standards The UPS is designed with the applicable sections of UL, CUL, and ISO The UPS has UL and CUL listing. 1.0 Scope This document describes the specification for Toshiba 1000 Series On-Line Uninterruptible Power System (UPS). The UPS will supply a computer grade AC output sine wave which is unaffected by the

More information

Model 865 RF / Ultra Low Noise Microwave Signal Generator

Model 865 RF / Ultra Low Noise Microwave Signal Generator Model 865 RF / Ultra Low Noise Microwave Signal Generator Features Excellent signal purity: ultra-low phase noise and low spurious Combination of highest output power and fastest switching Powerful touch-display

More information

RS Pro ENGLISH. Datasheet

RS Pro ENGLISH. Datasheet Datasheet ENGLISH Article No: 136-5390 Digital AC Ammeter, 48x96, 3Phase, 1 or 5 Amps AC, Supply 40-300V ac/dc 136-5391 Digital AC Ammeter, 96x96, 3Phase, 1 or 5 Amps AC, Supply 40-300V ac/dc 136-5393

More information

Multimeter 560CVD11 Data sheet

Multimeter 560CVD11 Data sheet RTU500 series Multimeter 560CVD11 Data sheet The fault current is measured up to 20 times nominal current. The current inputs withstand 50 times nominal current for 1 s. The Multimeter is equipped with

More information

Harmonic control devices. ECE 528 Understanding Power Quality

Harmonic control devices. ECE 528 Understanding Power Quality ECE 528 Understanding Power Quality http://www.ece.uidaho.edu/ee/power/ece528/ Paul Ortmann portmann@uidaho.edu 208-733-7972 (voice) Lecture 12 1 Today Harmonic control devices In-line reactors (chokes)

More information

Digital Multifunction Instrument - Rish Master 3440

Digital Multifunction Instrument - Rish Master 3440 Application Rish Master 3440 measures important electrical parameters in 3 phase and single phase etwork & replaces the multiple analog panel meters. It measures electrical parameters like AC current,

More information

SFX Form Factor SST-SX650-G SST-SX500-G. The standard SFX power supply benchmark

SFX Form Factor SST-SX650-G SST-SX500-G. The standard SFX power supply benchmark SFX Form Factor SST-SX650-G SST-SX500-G The standard SFX power supply benchmark Support standard SFX form factor Silent running 92mm fan with 18 dba minimum All Japanese capacitors High efficiency with

More information

Phoenix DX Clean Power (18 Pulse) AC Drive

Phoenix DX Clean Power (18 Pulse) AC Drive PHOENIX DX Phoenix DX Clean Power (18 Pulse) AC Drive Poor power quality can be costly. Nonlinear loads, including AC Drives, introduce undesirable harmonic currents into the power system that can damage

More information

Fundamentals of Power Quality

Fundamentals of Power Quality NWEMS Fundamentals of Power Quality August 20 24, 2018 Seattle, WA Track D Anaisha Jaykumar (SEL) Class Content» Introduction to power quality (PQ)» Causes of poor PQ and impact of application» PQ characteristics»

More information

SHUNT ACTIVE POWER FILTER

SHUNT ACTIVE POWER FILTER 75 CHAPTER 4 SHUNT ACTIVE POWER FILTER Abstract A synchronous logic based Phase angle control method pulse width modulation (PWM) algorithm is proposed for three phase Shunt Active Power Filter (SAPF)

More information

Applications. Other applications include:

Applications. Other applications include: California Instruments CSW Series High Performance Programmable AC and DC Power Source Combination AC and DC Power Source 2Hz-7,990Hz Output Frequencies Arbitrary and Harmonic Waveform Generation Built-In

More information

User s Guide. DDS-3005 USB Operation Manual

User s Guide. DDS-3005 USB Operation Manual User s Guide DDS-3005 USB Operation Manual Table of Contents Chapter 1 Introduction...1 1.1 Introduction...1 1.2 Working Principle...1 1.3 Hardware Specification...1 Chapter 2 Installation...3 2.1 System

More information

DDS-3005 USB Arbitrary Waveform Generator and. Frequency Counter. Operation Manual V1.9

DDS-3005 USB Arbitrary Waveform Generator and. Frequency Counter. Operation Manual V1.9 DDS-3005 USB ManualV1.9 1 DDS-3005 USB Arbitrary Waveform Generator and Frequency Counter Operation Manual V1.9 Introduction 1.1 Introduction DDS-3005 USB Arbitrary Waveform Generator has one channel of

More information

VIM Series. 90 & 60 W, Efficient, CV Class 2 LED Drivers ORDERING INFORMATION

VIM Series. 90 & 60 W, Efficient, CV Class 2 LED Drivers ORDERING INFORMATION 060W-12 100W-24 Nominal Input Voltage 90 &, Efficient, CV Class 2 Max. Output Power Nominal Output Voltage Max. Output Current 120 & 277 Vac 12, 24 Vdc 5, 3.75 A Efficiency up to 90% typical Max. Case

More information

DIGITAL POWER METER MODEL 66203/66204 MODEL 66203/66204 KEY FEATURES

DIGITAL POWER METER MODEL 66203/66204 MODEL 66203/66204 KEY FEATURES MODEL 6603/6604 DIGITAL POWER METER MODEL 6603/6604 C h r o m a 6603/6604 P o w e r M e t e r s are designed for multiple phase power measurement applications. The wiring mode function allows the user

More information

RISH EM 3490 SS Kilowatt Hour Energy Meter With Rs485 RISH EM 3490 SS. Application : Product Features: Indication: Pulse Indication:

RISH EM 3490 SS Kilowatt Hour Energy Meter With Rs485 RISH EM 3490 SS. Application : Product Features: Indication: Pulse Indication: Application : RISH Master 3490 SS is a 96mm x 96mm panel mounted kilowatt hour meter it measures active energy with class 1.0 accuracy having auto-resetting 8 digit seven segment LED counter. The unit

More information

SAMSUNG ELECTRO-MECHANICS CO., LTD

SAMSUNG ELECTRO-MECHANICS CO., LTD Model Name : Features : ㅡ Suitable for LED lighting application ㅡ UL8750, UL1310 Class 2 ㅡ For use in Dry and Damp Location ㅡ Full-protection provided: OCP/OVP/OTP/SCP ㅡ 0-10V Dimming Control ㅡ IP67 ㅡ

More information

4Q POWER AMPLIFIERS AC AND DC 3000VA 3x3000VA

4Q POWER AMPLIFIERS AC AND DC 3000VA 3x3000VA PERFORMANCES High accuracy High stability Fast transients High inrush current facilities Wide bandwidth 25 khz at -3dB Internal waveform DC and up to 10 khz Very low distortion Quadrant change without

More information

LDP Series - 75W Outdoor Programmable Driver

LDP Series - 75W Outdoor Programmable Driver LDP Series - 75W Outdoor Programmable Driver Product Features Universal input voltage / Full range: 90~305Vac; Constant power design, outputs programmable; Output current reconfigurable by infrared controller;

More information

EMC TEST REPORT. For. Switching Mode Power Adaptor. Model No.: 9W/14.4V/EU(18V/1.0A), 19W/14.4V/EU(12V/1.5A)

EMC TEST REPORT. For. Switching Mode Power Adaptor. Model No.: 9W/14.4V/EU(18V/1.0A), 19W/14.4V/EU(12V/1.5A) EMC TEST REPORT For Company Limited Liability «Faraday Electronics» Switching Mode Power Adaptor Model No.: 9W/14.4V/EU(18V/1.0A), 19W/14.4V/EU(12V/1.5A) Prepared For : Company Limited Liability «Faraday

More information

Harmonic Current emission EN :2014 Class A Pass. Voltage Fluctuation and Flicker EN :2013 Clause 5 Pass

Harmonic Current emission EN :2014 Class A Pass. Voltage Fluctuation and Flicker EN :2013 Clause 5 Pass Reference No.: WTS15F0323845E Page 2 of 33 1 Test Summary Test Item Mains Terminal Disturbance Voltage, 148.5kHz to 30MHz Disturbance Power, 30MHz to 300MHz Discontinuous Disturbance (Click) Radiated Emission,

More information

Low Frequency Measuring System

Low Frequency Measuring System Emission Measurements Low Frequency Measuring System Brief Overview of Phenomena............... 2 Applicable Standards................... 3 Test System Overview.................. 4 Generator Specifications.................

More information

1000W Single Output Medical Type. MSP-1000 series. File Name:MSP-1000-SPEC

1000W Single Output Medical Type. MSP-1000 series. File Name:MSP-1000-SPEC 000W Single Output Medical Type MSP-000 series File Name:MSP-000-SPEC 08-05-04 000W Single Output Medical Type MSP-000 series SPECIFICATION MODEL MSP-000- MSP-000-5 MSP-000-4 MSP-000-48 DC VOLTAGE V 5V

More information

Power Amplifiers. Power with Precision

Power Amplifiers. Power with Precision Power Amplifiers EXPERIENCE Supplier Since 1984 Leader in PWM Design Technology Thousands of Amplifier Installations Wide Range of Application Custom Engineering Support Copley Controls has led the industry

More information

Power Quality Measurements the Importance of Traceable Calibration

Power Quality Measurements the Importance of Traceable Calibration Power Quality Measurements the Importance of Traceable Calibration H.E. van den Brom and D. Hoogenboom VSL Dutch Metrology Institute, Delft, the Netherlands, hvdbrom@vsl.nl Summary: Standardization has

More information

DIGITAL POWER METER MODEL 66203/66204 MODEL 66203/ Digital Power Meter. Key Features

DIGITAL POWER METER MODEL 66203/66204 MODEL 66203/ Digital Power Meter. Key Features Digital Power Meter MODEL 6603/6604 Key Features DIGITAL POWER METER MODEL 6603/6604 Voltage Ranges : 15/30/60/150/300/600 Vrms, 100Vrms (optional kit) Current Ranges : 0.005/0.0/0.05/0./0.5//5/0 Arms

More information

Watts HCP Series

Watts HCP Series ACDC 6 Watts HCP Series High Efficiency up to 9% xppower.com High Power Density Programmable Output Voltage (%%) Programmable (%%) Parallel Operation Fully Featured Signals & Controls Year Warranty Specification

More information

MICROPROCESSOR-BASED METERING EQUIPMENT SECTION 16901C PART 2

MICROPROCESSOR-BASED METERING EQUIPMENT SECTION 16901C PART 2 PART 1 PART 2 PRODUCTS 2.01 MANUFACTURERS A. Eaton products B.. C.. The listing of specific manufacturers above does not imply acceptance of their products that do not meet the specified ratings, features

More information

PROGRAMMABLE AC SOURCE 61501/61502/61503/61504 User s Manual

PROGRAMMABLE AC SOURCE 61501/61502/61503/61504 User s Manual PROGRAMMABLE AC SOURCE 61501/61502/61503/61504 User s Manual Version 1.1 February 2004 P/N A11 000568 Legal Notices The information in this document is subject to change without notice. Chroma ATE INC.

More information

PROGRAMMABLE DC POWER SUPPLY MODEL 62000H SERIES MODEL 62000H SERIES. Programmable DC Power Supply. Key Features :

PROGRAMMABLE DC POWER SUPPLY MODEL 62000H SERIES MODEL 62000H SERIES. Programmable DC Power Supply. Key Features : Programmable DC Power Supply MODEL 62000H SERIES Key Features : PROGRAMMABLE DC POWER SUPPLY MODEL 62000H SERIES Chroma's new 62000H Series of programmable DC power supplies offer many unique advantages

More information

Typical Efficiency (2)

Typical Efficiency (2) EUC030SxxxDVM Features Low THD, 10% Max up to 240 Vac Compact Metal Case with Excellent Thermal Performance Isolated 010V Dimmable Input Surge Protection: 4kV lineline, 6kV lineearth High Reliability &

More information

Contents. ZT530PCI & PXI Specifications. Arbitrary Waveform Generator. 16-bit, 400 MS/s, 2 Ch

Contents. ZT530PCI & PXI Specifications. Arbitrary Waveform Generator. 16-bit, 400 MS/s, 2 Ch ZT530PCI & PXI Specifications Arbitrary Waveform Generator 16-bit, 400 MS/s, 2 Ch Contents Outputs... 2 Digital-to-Analog Converter (DAC)... 3 Internal DAC Clock... 3 Spectral Purity... 3 External DAC

More information

Typical Efficiency (2)

Typical Efficiency (2) EUC030SxxxDTM Features Low THD, 10% Max up to 240 Vac Compact Metal Case with Excellent Thermal Performance Isolated 010V Dimmable Input Surge Protection: 4kV lineline, 6kV lineearth High Reliability &

More information

HRPG-1000 series. 1000W Single Output with PFC Function. File Name:HRPG-1000-SPEC Sicherheit ID

HRPG-1000 series. 1000W Single Output with PFC Function. File Name:HRPG-1000-SPEC Sicherheit ID 000W Single Output with PFC Function HRPG-000 series Bauart gepruft Sicherheit egelma ge od o s be wac g www. tuv.com ID 000000000 File Name:HRPG-000-SPEC 08-05-04 000W Single Output with PFC Function

More information

Power Factor (2) 600 ma 90 ~ 305 Vac Vdc 34.2 W 86% 0.95 LUC-040S060RSP. Efficiency (2) Parameter Min. Typ. Max. Notes

Power Factor (2) 600 ma 90 ~ 305 Vac Vdc 34.2 W 86% 0.95 LUC-040S060RSP. Efficiency (2) Parameter Min. Typ. Max. Notes Features Trailing Edge AC Dimmable Constant Current Output High Efficiency (Up to 86%) Active Power Factor Correction (Up to 0.95) All-Around Protection: OVP, SCP and OLP Description The series operates

More information

Model and Output Power Output Nominal Voltage Package Option Means of Protection Grade. 12 V DC: -US12 Open Frame: -OF. 24 V DC: -US24 U-Chassis: -UC

Model and Output Power Output Nominal Voltage Package Option Means of Protection Grade. 12 V DC: -US12 Open Frame: -OF. 24 V DC: -US24 U-Chassis: -UC 2XMOPP MEDICAL, 400 W ACDC COMPACT, EFFICIENT POWER SUPPLY MDP400 SERIES DESCRIPTION The MDP400 series of medical ACDC power supplies feature a compact form factor, high conversion efficiency and 2x MoPP

More information

Chapter 6 Specifications

Chapter 6 Specifications RIGOL This chapter lists the technical specifications and general specifications of the RF signal generator. The technical specifications are valid when the instrument is within the calibration period,

More information

VGM Series. 100 & 60 W, Efficient, CV Class 2 LED Drivers for Signage Applications ORDERING INFORMATION

VGM Series. 100 & 60 W, Efficient, CV Class 2 LED Drivers for Signage Applications ORDERING INFORMATION Nominal Input Voltage Max. Output Power Nominal Output Voltage Max. Output Current 120/277 Vac 12, 24, Vdc 5, 3.92 A Efficiency up to 90% typical Max. Case Temperature 100 C (measured at the hot spot)

More information

Keysight 6800C Series AC Power Source/Analyzers, VA

Keysight 6800C Series AC Power Source/Analyzers, VA Keysight 6800C Series AC Power Source/Analyzers, 375-1750 VA An integrated AC power solution Data Sheet Provides a complete AC and DC power and measurement solution Protect valuable DUTs with extensive

More information

Application Alpha 20 Measures important electrical parameters in 3 phase 4 Wire and 3 phase 3 Wire Network & replaces the multiple analog panel meters

Application Alpha 20 Measures important electrical parameters in 3 phase 4 Wire and 3 phase 3 Wire Network & replaces the multiple analog panel meters Technical Data Sheet Alpha 20 Alpha 20 is a compact multifunction instrument which Measures important electrical parameters in 3 phase 4 Wire and 3 phase 3 Wire Network & replaces the multiple analog panel

More information

80W Single Output Switching Power Supply

80W Single Output Switching Power Supply SPECIFICATION MODEL OUTPUT INPUT PROTECTION ENVIRONMENT SAFETY & EMC OTHERS NOTE DC VOLTAGE CONSTANT CURRENT REGION Note.4 RATED CURRENT RATED POWER RIPPLE & NOISE (max.) Note. 0mVp-p 0mVp-p 0mVp-p 0mVp-p

More information

PA-AB 4Q POWER AMPLIFIER VA Page 1/5

PA-AB 4Q POWER AMPLIFIER VA Page 1/5 PA-AB 4Q POWER AMPLIFIER 600-1000-2000-3000-5000VA Page 1/5 PA series is a real 4 quadrants AC+DC amplifier to test or simulate all kind of loads or generators with power, high dymamic, a low distortion

More information

Data Sheet. RISH Master Record %THD

Data Sheet. RISH Master Record %THD Data Sheet %THD Application : measures important electrical parameters & replaces the multiple analog panel meters. It measures electrical parameters like AC current, Voltage, frequency, active energy

More information

PQ-Box 100 Network Analyzer for Low-, Medium- and High-Voltage Networks

PQ-Box 100 Network Analyzer for Low-, Medium- and High-Voltage Networks GB Technical data Issue 06/2009 PQ-Box 100 Network Analyzer for Low-, Medium- and High-Voltage Networks Fault detection Evaluation of voltage quality according to EN50160 and IEC61000-2-2 Fault recorder

More information

Power Quality Analysers

Power Quality Analysers Power Quality Analysers Review of Power Quality Indicators and Introduction to Power Analysers ZEDFLO Australia 6-Mar-2011 www.zedflo.com.au Power Quality Indicators Review of main indicators of electrical

More information

RISH EM 3490 DS Dual Source Energy Meter (With All Display Parameters) RISH EM 3490 DS. Application : Product Features:

RISH EM 3490 DS Dual Source Energy Meter (With All Display Parameters) RISH EM 3490 DS. Application : Product Features: (With All Display Parameters) Application : RISH EM 3490 DS measures important electrical parameters of Utility (in normal mode) & Generators (in Power back up) in three phase and single phase Network

More information

RISH Delta Energy / Demand (Multifunction instrument) Data Sheet

RISH Delta Energy / Demand (Multifunction instrument) Data Sheet ISH Delta Energy / Demand (Multifunction instrument) Data Sheet www.rishabh.co.in Page 1 of 6 Version: D 14 / 03 / 2012 Application: ISH Delta Energy measures important electrical parameters in 3 phase

More information

LCM-40DA/AUX Series 40W Multiple-Stage Constant Current LED Power Supply

LCM-40DA/AUX Series 40W Multiple-Stage Constant Current LED Power Supply Features Constant Current mode output with multiple levels selectable by dip switch Plastic housing with class II design Built-in active PFC function Standby Power consumption

More information

Typical Efficiency (2) 350 ma 90 ~ 305 Vac 37 ~ 74 Vdc 26 W 88.5% EUC-026S050SVM0003

Typical Efficiency (2) 350 ma 90 ~ 305 Vac 37 ~ 74 Vdc 26 W 88.5% EUC-026S050SVM0003 EUC026SxxxSVM000x Features Low THD, 10% Max up to 240 Vac Compact Metal Case with Excellent Thermal Performance Input Surge Protection: 4kV lineline, 6kV lineearth High Reliability & Long Lifetime: 84,000

More information

PQ Monitoring Standards

PQ Monitoring Standards Characterization of Power Quality Events Charles Perry, EPRI Chair, Task Force for PQ Characterization E. R. Randy Collins, Clemson University Chair, Working Group for Monitoring Electric Power Quality

More information

EV series of AC voltage amplifiers

EV series of AC voltage amplifiers EV series of AC voltage amplifiers Wide frequency range AC power amplifier system The applications: - Component testing - Measuring equipment testing - Ignition pulse testing (lighting equipment) High

More information

LDP Series - 240W Outdoor Programmable Driver

LDP Series - 240W Outdoor Programmable Driver Product Features Universal input voltage / Full range: 90~305Vac; Constant power design, outputs programmable; Output current reconfigurable by infrared controller; 3-in-1 dimmable (M types): 0~10Vdc /

More information

Stabilized Differential Relay SPAD 346. Product Guide

Stabilized Differential Relay SPAD 346. Product Guide Issued: July 1998 Status: Updated Version: D/21.03.2006 Data subject to change without notice Features Integrated three-phase differential relay, three-phase overcurrent relay and multiconfigurable earth-fault

More information

i Series ix Series AC Power Source User Manual

i Series ix Series AC Power Source User Manual i Series ix Series AC Power Source User Manual Revision Z November 2005 Copyright 1998-2005 by. All rights reserved. P/N 7000-970 User's Manual AC Power Source Models : 3001i 5001i 5001i-400 9003i 10001i

More information