CS114 + CS115 + CS116

Save this PDF as:
 WORD  PNG  TXT  JPG

Size: px
Start display at page:

Download "CS114 + CS115 + CS116"

Transcription

1 System description Test Setup for MIL-STD-461 D, E&F CS114 + CS115 + CS MONTENA EMC PRODUCTS TURN KEY MIL STD 461 TEST INSTALLATIONS TEST SETUP DESCRIPTION TEST SETUP CALIBRATION SETUP INJECTED PERTURBATIONS CS 115 SQUARE PULSE GENERATOR CS 116 DAMPED SINUSOIDAL PULSE GENERATOR CONTROL INTERFACE FOR FULLY AUTOMATED SYSTEM OTHER MEASUREMENT SYSTEMS & ACCESSORIES INJECTION PROBE WITH CALIBRATION JIG LISN SERVICES ONSITE INSTALLATION AND TRAINING MAINTENANCE TECHNICAL SPECIFICATIONS Version VoF V:\Marketing\Prospectus_produits\SystemDescriptionDocuments\CS114_115_116_Test_Setup_Description.DOC 1/15

2 1. Montena emc Since its foundation in 1978, montena emc has earned a worldwide reputation for its leading-edge skills in the fields of high voltage, high frequency and electromagnetic fields. Montena emc is number one EMC test lab in Switzerland, with a team of 35 people (23 engineers). With two large anechoic chambers, an open area test site and multiple shielded rooms, montena can test and validate all kinds of equipment. Figure 1 : Montena emc headquarters - helicopter in an anechoic chamber montena emc laboratory is accredited by SAS (Swiss Accreditation Service) for the calibration of EMC measuring devices as well as for the verification of the electrical safety of equipment and devices according to European Union directives and to the Swiss legislation. Montena can count on highly specialized specialised know-how in the field of electromagnetic compatibility. These skills are put to good use in our EMC laboratories as well as in the development and construction of various kinds of equipment. In the field of high voltage and high frequencies, montena's engineers are masters of the techniques used to generate rapid fast pulses, including those to endow them with special characteristics. 2/15

3 1.1 Products Montena emc designs, builds and markets equipment and accessories for EMC tests. The range of products includes antennas, TEM cells, striplines, field sensors, all kind of pulse generators, test benches, etc. Montena's high voltage pulse generators are mainly used for EMC tests, ultra-rapid imaging and pulsed light decontamination. Montena also builds pulse generators according the custom specific needs. Figure 2 : some of montena emc products 1.2 Turn key MIL STD 461 test installations Montena has developed and sold worldwide turnkey test setups for MIL-STD 461 test as RS 101, CS 101, CS 114, CS 115, CS 116 and RS 105. Figure 3 : example of test setup from montena 3/15

4 2. Test setup description 2.1 Test setup montena s fully automated test setup for MIL-STD 461, CS comprises following elements: PC Pulse generator Damped sinusoidal generator Signal generator Oscilloscope Amplifier & directional coupler HF Switch Power input LISN EUT Injection probe Current probe Figure 4 : schematic of a typical CS 116 test setup installation The pulse generators and the signal generator + amplifiers are connected to the current injection probe through a high voltage, high frequency, remotely controlled switch. The 3 tests can be performed fully automatically without any re-connection of cables. An oscilloscope connected to a current probe checks the level of the injected perturbation. LISN are to be used to control the impedance on the power line. A PC with a control software allows fully automatic calibration and test sequences, as well as the automatic generation of test reports. One single signal output Thanks to the HF switch, the whole calibration or the measurement phase can be performed for the 3 tests without any need to change the cabling, considerably reducing the calibration and measurement time. 4/15

5 2.2 Calibration setup MIL-STD 461, CS calibration for the 3 tests can be performed fully automatically without any re-connection of cables PC Pulse generator Damped sinusoidal generator Signal generator Oscilloscope Amplifier & directional coupler HF Switch 50 Ωload attenuator Injection probe with calibration ficture Figure 5 : schematic of a CS calibration setup 5/15

6 2.3 Injected perturbations CS114 injected signal and level CS 114 test system delivers the CW signal according to MIL-STD 461 D, E and F versions. In the control software the user can select the test signal level based on the defined curves and table taken from the standards. Figure 6 : MIL-STD-461 D, E&F CS114 current level In the automatic mode (software controlled) the system calibration will automatically determine the required generator's output level to obtain the specified current injection level. 6/15

7 CS115 pulse shape and level CS 115 test system delivers a square pulse according to MIL-STD 461 D, E and F versions. Figure 7 : MIL-STD-461 D, E&F CS115 pulse shape In the automatic mode (software controlled) the current injection level can be defined and the system calibration will automatically determine the required generator's output level to obtain the specified current injection level. CS116 pulse shape and level CS 116 test system delivers a damped sinusoidal pulse according to MIL-STD 461 D, E and F versions. Figure 8 : MIL-STD-461 D, E&F CS116 pulse shape The damped sinusoidal pulse level can be manually tuned to obtain the required current injection level. 7/15

8 Note: in the MIL-STD 461 D&E versions, two levels are defined with 1. For Army and Navy procurements, IMAX = 10 amperes 2. For Air Force procurements, IMAX = 5 amperes Figure 9 : MIL-STD-461 D, E&F CS116 pulse current level In the automatic mode (software controlled) the current injection level can be defined for each available discrete frequency and the system calibration will automatically determine the required generator's output level to obtain the specified current injection level. 8/15

9 3. CS 115 square pulse generator Figure 10: Montena pulse generator for CS 115 Control panel The control panel allows the user to select the desired output voltage and the pulse repetition rate. The generator can be controlled by the front panel or remotely from the control software. 4. CS 116 damped sinusoidal pulse generator The damped sinusoidal generator POG_116 xf can be supplied with 6 to 16 discrete frequencies. Figure 11: Montena pulse generator for CS 116 9/15

10 Menu driven control panel The menu driven control panel allows the user to select the desired discrete frequency, the pulse voltage level, the repetition rate and the number of pulse to be generated. > Volt. = 070.0% Voltage in % of maximum level Freq. = 1MHz Frequency Rate = 0.5Hz Nbr Repetition rate = 019/600 L Number of pulses (current count/fixed number) From 6 to 16 frequencies The MIL STD 461 D, E & F CS116 requires testing the susceptibility at 6 discrete frequencies between 10 khz and 100 MHz. Montena's CS116 generator provides additional frequencies too: Oscillation frequency Damping factor 1) Maximal current 1) PDG116-6F PDG116-9F PDG116-12F PDG116-16F 10 khz A x x x x 30 khz 2) A x x x 100 khz A x x x x 300 khz 2) A x x x 1 MHz A x x x x 3 MHz 2) A x x x 10 MHz A x x x x 20 MHz 2) A x x 30 MHz A x x x x 40 MHz 2) A x 50 MHz 2) A x x 60 MHz 2) A x 70 MHz 2) A x x 20 MHz 2) A x 20 MHz 2) A x 100 MHz A x x x x 1) 2) At 100 % voltage setting and with a 2 m 50 Ω coaxial cable, with the dedicated injection probe (e.g. Prâna IP-DR250) and calibration jig, on the 100 ohm calibration load. These frequencies are not required by the MIL STD 461 but we recommend them to have a better coverage of the frequency range. 10/15

11 6 frequencies 9 frequencies 12 frequencies 16 frequencies Figure 12: Available CS116 test frequencies In some cases it is very interesting to be able to test the susceptibility of the equipment with some inbetween frequencies which will be present in the real deployment and will threaten the equipment's performances. Optionally montena can provides some additional discrete frequencies anywhere in the range comprised between 10 khz and 100 MHz. 11/15

12 5. Control interface for fully automated system The remote control can be carried out through the RS 232, USB or GPIB. The CS test setup from montena is supplied with a dedicated control software with graphical user interface as shown below. This control software comprises: Figure 13 : CS116 control software A main panel to select the desired tests to be performed A calibration panel allowing a fully automated calibration of the system. A measurement panel allowing a fully automated measurement phase with sequential injection of the defined current level for each selected test standard and at each available discrete frequency. A report generation to keep track of measurements as well as of calibrations. 12/15

13 6. Other measurement systems & accessories 6.1 Injection probe with calibration jig The injection probe is required for both measurement and for the calibration phases. For the system calibration phase, the current injection probe is calibrated with help of a calibration jig, an attenuator and a 50 ohm termination load. 6.2 LISN The LISN (Line Impedance Stabilisation Network) are used to provide standardised impedance in common mode to the power lines connected to the EUT. This allows a better reproducibility of the tests. The LISN50-25 fulfils the MIL-STD 461 D,E and F requirements 50 Ω // 50 µh 1 x 25 A 230 Vac (50/60 Hz) Vac (400 Hz) 7. Services 7.1 Onsite installation and training Montena emc provides onsite installation and training performed by either an engineer from montena emc or by a local authorized representative support engineer. A training session is usually given directly after installation. This training includes both the test system operation and maintenance. 7.2 Maintenance No periodical maintenance is required other than a calibration of the measurement equipment. On customer request montena can offer this calibration service with support of montena's authorized local representative. 13/15

14 8. Technical specifications Technical specifications of the CS115 pulse generator Generator type Nominal charging voltage Output waveform Output impedance Rise time (10 90%) Fall time (90 10%) Pulse duration (50 50%) Repetition rates Pulse number (repetitive mode) Output signal connexion Power rating square pulse 0-5 kv square 50 ohm 700 ps 1.5 ns > 30 ns 1-60 Hz pulses N 50 ohm V ac / Hz / 35 W / 75 VA Safety complies with EN EMC complies with EN Interface RS 232 (Sub-D 9 pins female connector) Storage temperature 5-50 C Working temperature C Relative humidity maximum 60 % Generator weight Dimensions (L x W x H) 7kg 36 cm x 35 cm x 16 cm 14/15

15 Technical specifications of the CS116 pulse generator Generator type Nominal charging voltage Output waveform Output impedance damped transient wave 15 kv positive only damped oscillatory wave < 100 ohm Damping factor 15 +/- 5 Repetition rates Pulse number (repetitive mode) Maximum sequence duration Mechanical life single, 0.5 Hz, 1 Hz pulses 20 min. 1 million pulses at each frequency in the range 3 MHz to 100 MHz There is no mechanical devices in the range 10 khz to 1 MHz. Output signal connexion Power rating N 50 ohm V ac / Hz / 35 W / 75 VA Safety complies with EN EMC complies with EN Control interface RS 232 (Sub-D 9 pins female connector) Storage temperature 5-50 C Working temperature C Relative humidity maximum 60 % Generator weight Dimensions (L x W x H) 27.5 kg (for 9 frequencies) 53 cm x 53 cm x 45 cm 15/15

MIL Standard 461 G. final release December 11 th, EMC PARTNER - Largest range of impulse test equipment up to 100kV and 100kA

MIL Standard 461 G. final release December 11 th, EMC PARTNER - Largest range of impulse test equipment up to 100kV and 100kA MIL Standard 461 G final release December 11 th, 2015 EMC PARTNER - Largest range of impulse test equipment up to 100kV and 100kA CDN-UTP8 Ed. 3 - Universal The Swiss CDN company for data EMC and telecom

More information

EMC PARTNER. DO-160 & MIL-STD-461G TEST SYSTEM Indirect Lightning Testing

EMC PARTNER. DO-160 & MIL-STD-461G TEST SYSTEM Indirect Lightning Testing EMC PARTNER DO-160 & MIL-STD-461G TEST SYSTEM Indirect Lightning Testing This document has been optimized for electronic media Accredited Calibration Quality at EMC PARTNER is based on an ISO 9001 management

More information

A Comparison Between MIL-STD and Commercial EMC Requirements Part 2. By Vincent W. Greb President, EMC Integrity, Inc.

A Comparison Between MIL-STD and Commercial EMC Requirements Part 2. By Vincent W. Greb President, EMC Integrity, Inc. A Comparison Between MIL-STD and Commercial EMC Requirements Part 2 By Vincent W. Greb President, EMC Integrity, Inc. OVERVIEW Compare and contrast military (i.e., MIL-STD) and commercial EMC immunity

More information

Immunity Test System RIS 3000 / RIS 6000 acc. to IEC/EN

Immunity Test System RIS 3000 / RIS 6000 acc. to IEC/EN Description The setup of a radiated immunity test system can be done in the conventional way with many separate instruments or in a more comfortable and less risky way with our new EMC control unit, type

More information

TEST SUMMARY Seite 2 von 27. Prüfbericht - Nr.: Test Report No HARMONICS ON AC MAINS RESULT: Passed

TEST SUMMARY Seite 2 von 27. Prüfbericht - Nr.: Test Report No HARMONICS ON AC MAINS RESULT: Passed 17035561 001 Seite 2 von 27 Page 2 of 27 TEST SUMMARY 5.1.1 HARMONICS ON AC MAINS RESULT: Passed 5.1.2 VOLTAGE FLUCTUATIONS ON AC MAINS RESULT: Passed 5.1.3 TERMINAL CONTINUOUS DISTURBANCE VOLTAGE AT RESULT:

More information

PURCHASE DIVISION DEPARTMENT QUALITY MANUAL Revision No. : 02 Issue No: : 2 Dt of Revision : Issue Dt. :

PURCHASE DIVISION DEPARTMENT QUALITY MANUAL Revision No. : 02 Issue No: : 2 Dt of Revision : Issue Dt. : Section : 0 Document : DQM-01 Topic : FORMAT 6 OF PROCUREMENT PROCEDURE OF CPRI (NON-WORKS) Section I(B)-Technical Specification Tender Enquery No PUR/UARC-02/14-15 Name of the Equipment: Damped Oscillatory

More information

COMMUNICATING THROUGH THE AGES

COMMUNICATING THROUGH THE AGES COMMUNICATING THROUGH THE AGES If you are as ancient as I am, you will remember when the only two-way communication was by land-line telephone or telegraph, radio telegraph between ships, and a few specialized

More information

Combination Wave Test System

Combination Wave Test System Immunity Tests Combination Wave Test System Brief Overview of Phenomena............... 2 Applicable Standards................... 3 Test System Overview.................. 4 Generator Specifications.................

More information

MGA Magnetic field system. DC khz

MGA Magnetic field system. DC khz MGA 1030 Magnetic field system DC - 250 khz EN 55103-1 + 2, EN 61000-4-8, Automotive, MIL-STD a.o. Generation and measurement of magnetic fields from DC up to 250 khz Field strengths up to 1000 A/m Additional

More information

2520 Pulsed Laser Diode Test System

2520 Pulsed Laser Diode Test System Complete pulse test of laser diode bars and chips with dual photocurrent measurement channels 0 Pulsed Laser Diode Test System Simplifies laser diode L-I-V testing prior to packaging or active temperature

More information

EMC Precompliance Systems and Accessories Catalog

EMC Precompliance Systems and Accessories Catalog EMC Precompliance Systems and Accessories Catalog Agilent 84115EM EMC precompliance systems Agilent E7402A and E7405A EMC precompliance analyzers Agilent E7415A EMC measurement software Agilent EMC precompliance

More information

OCS 500N6F SERIES SIMULATOR FOR FAST AND SLOW DAMPED OSCILLATORY WAVES AND RINGWAVE

OCS 500N6F SERIES SIMULATOR FOR FAST AND SLOW DAMPED OSCILLATORY WAVES AND RINGWAVE OCS 500N6F SERIES SIMULATOR FOR FAST AND SLOW DAMPED OSCILLATORY WAVES AND RINGWAVE FOR TESTS ACCORDING TO... > ANSI/IEEE C37.90 > ANSI/IEEE C62.41 > EN 61000-4-10 > EN 61000-4-12 > EN 61000-4-18 > IEC

More information

Schlöder GmbH - EMC Test and Measurement Systems Model #

Schlöder GmbH - EMC Test and Measurement Systems Model # Schlöder GmbH - EMC Test and Measurement Systems Model # Product Description IEC / EN 61000-4 - 2 ESD SESD 216 ESD generator 10 kv CON / 16,5 kv AIR acc. to IEC 61000-4-2, 150 pf / 330 ohm SESD 230 ESD

More information

We re In The Business Of Making Your Life Easier

We re In The Business Of Making Your Life Easier Systems RF Conducted Immunity System We re In The Business Of Making Your Life Easier AS00202 4 khz 200 MHz System AS03007 10 khz 3 GHz System RF Conducted Immunity Testing to IEC, Military & Automotive

More information

Insulation Test System

Insulation Test System Component Tests Insulation Test System Brief Overview of Phenomena............... 2 Applicable Standards................... 3 Test System Overview.................. 3 Generator Specifications.................

More information

2620 Modular Measurement and Control System

2620 Modular Measurement and Control System European Union (EU) Council Directive 89/336/EEC Electromagnetic Compatibility (EMC) Test Report 2620 Modular Measurement and Control System Sensoray March 31, 2006 April 4, 2006 Tests Conducted by: ElectroMagnetic

More information

SEMS SHIELDING EFFECTIVENESS MEASUREMENT SYSTEM IN MRI AND SHIELDED ENVIRONMENT. ELECTRIC AND MAGNETIC FIELD FROM 10 khz TO 300 MHz*

SEMS SHIELDING EFFECTIVENESS MEASUREMENT SYSTEM IN MRI AND SHIELDED ENVIRONMENT. ELECTRIC AND MAGNETIC FIELD FROM 10 khz TO 300 MHz* SEMS SHIELDING EFFECTIVENESS MEASUREMENT SYSTEM IN MRI AND SHIELDED ENVIRONMENT ELECTRIC AND MAGNETIC FIELD FROM 10 khz TO 300 MHz* SEMS SHIELDING EFFECTIVENESS MEASUREMENT SYSTEM MRI Shielding Environment

More information

Harmonizing the ANSI-C12.1(2008) EMC Tests. Harmonizing the ANSI-C12.1(2008) EMC Tests

Harmonizing the ANSI-C12.1(2008) EMC Tests. Harmonizing the ANSI-C12.1(2008) EMC Tests Harmonizing the ANSI-C12.1(2008) EMC Tests Subcommittee 1 (Emissions) Subcommittee 5 (Immunity) Joint Task Force on C12.1 June 17, 2013 1 The Accredited Standards Committee C63 presents Harmonizing the

More information

Downloaded from 1. THE FOLLOWING PAGES OF MIL-STD-462D HAVE BEEN REVISED AND SUPERSEDE THE PAGES LISTED:

Downloaded from  1. THE FOLLOWING PAGES OF MIL-STD-462D HAVE BEEN REVISED AND SUPERSEDE THE PAGES LISTED: NOTICE OF CHANGE METRIC 10 April 1995 MILITARY STANDARD MEASUREMENT OF ELECTROMAGNETIC INTERFERENCE CHARACTERISTICS TO ALL HOLDERS OF : 1. THE FOLLOWING PAGES OF HAVE BEEN REVISED AND SUPERSEDE THE PAGES

More information

PROGRAMMABLE AC POWER SOURCE

PROGRAMMABLE AC POWER SOURCE Ihr Spezialist für Mess- und Prüfgeräte Programmable AC Power Source MODEL 61500 SERIES Key Features: PROGRAMMABLE AC POWER SOURCE MODEL 61500 SERIES Chroma AC power source 61500 series sets up waveform

More information

ER55 EMI TEST RECEIVER Family of automatic test receivers for measurement of electromagnetic interference from 9kHz to 1GHz

ER55 EMI TEST RECEIVER Family of automatic test receivers for measurement of electromagnetic interference from 9kHz to 1GHz ER55 EMI TEST RECEIVER Family of automatic test receivers for measurement of electromagnetic interference from 9kHz to 1GHz Compact designed and manufactured in compliance with CISPR 16-1, For Measurements

More information

The series allows users to compose. amplify the analog signal from arbitrary signal generator. Thus, it is capable of simulating the

The series allows users to compose. amplify the analog signal from arbitrary signal generator. Thus, it is capable of simulating the Programmable AC Power Source MODEL 61500 SERIES Key Features: PROGRAMMABLE AC POWER SOURCE MODEL 61500 SERIES Chroma AC power source 61500 series sets waveform as well as measurements such as up the new

More information

Insulation Test System

Insulation Test System Component Tests Insulation Test System Brief Overview of Phenomena............... 2 Applicable Standards................... 3 Test System Overview.................. 3 Generator Specifications.................

More information

via cable Route of signal interferences Shielding against radiation

via cable Route of signal interferences Shielding against radiation 1. Introduction In the vicinity of electronics and control systems, there is often high powered equipment and cabling. In these situations it is possible that electronic circuits can be affected by these

More information

Coupling / decoupling network (CDN) for screened or coaxial cables

Coupling / decoupling network (CDN) for screened or coaxial cables IEC / EN 61000-4-6 specifies the design and performance of a range of coupling / decoupling networks (CDNs). Each CDN is specific to the type of cable and the intended signal carried on the cable. Teseq

More information

Model 310H Fast 800V Pulse Generator

Model 310H Fast 800V Pulse Generator KEY FEATURES Temperature Stability +/-5ppm 100 V to 800 V into 50 Ω

More information

Application Note #38B Automotive 600V/m Radar Pulse Test Solution

Application Note #38B Automotive 600V/m Radar Pulse Test Solution Application Note #38B Automotive 600V/m Radar Pulse Test Solution By Applications Engineering There are many hazardous electrical events in the environment that can have adverse effects on the systems

More information

EMC Seminar Series All about EMC Testing and Measurement Seminar 1

EMC Seminar Series All about EMC Testing and Measurement Seminar 1 EMC Seminar Series All about EMC Testing and Measurement Seminar 1 Introduction to EMC Conducted Immunity Jeffrey Tsang Organized by : Department of Electronic Engineering 1 Basic Immunity Standards: IEC

More information

DDA55 DISCONTINUOUS DISTURBANCES ANALYSER

DDA55 DISCONTINUOUS DISTURBANCES ANALYSER DDA55 DISCONTINUOUS DISTURBANCES ANALYSER Fully digital analyser for measurement of discontinuous disturbances Compact designed and manufactured compliant to CISPR 16 International Standard for measurements

More information

R&S FSC Spectrum Analyzer Specifications

R&S FSC Spectrum Analyzer Specifications R&S FSC Spectrum Analyzer Specifications year Data Sheet Version 03.00 CONTENTS Base unit... 3 Frequency... 3 Sweep time... 3 Bandwidths... 3 Level... 4 Trigger functions... 5 Tracking generator (model.13/.16

More information

Mil Std 461E CS-115 CS-115 MIL STD 461E CS-115 CS-116 RS-105

Mil Std 461E CS-115 CS-115 MIL STD 461E CS-115 CS-116 RS-105 Mil Std 461E CS-115 CS-116 RS-105 Bruce Harlacher Fischer Custom Communications, Inc. MIL STD 461E CS-115 CS-116 RS-105 Purpose of Test History Type of Test What Is To Be Tested Calibration Setup Calibration

More information

Chambers Accessories Equipment 1 Equipment 2 Amplifiers Antennas Emission

Chambers Accessories Equipment 1 Equipment 2 Amplifiers Antennas Emission Chambers Accessories Equipment 1 Equipment 2 Amplifiers Antennas Emission Core-6 EMI Receiver 9 khz 6 GHz Features: Frequency ranges: 9 khz 30 MHz and 30 MHz 6 GHz Fully compliant acc. to CISPR 16-1-1

More information

Appendix A: Specifications

Appendix A: Specifications All specifications apply to the TDS 200-Series Digital Oscilloscopes and a P2100 probe with the Attenuation switch set to 10X unless noted otherwise. To meet specifications, two conditions must first be

More information

Guide on Implementation of Requirements of the Common EPS

Guide on Implementation of Requirements of the Common EPS Annex III to MoU regarding Harmonisation of a Charging Capability for Mobile Phones, June 5th, 2009 Date: Dec 15, 2011 Foreword: Guide on Implementation of Requirements of the Common EPS The MoU Signatories

More information

29050AA ACCELERATION SENSOR AIS 3520LN-010

29050AA ACCELERATION SENSOR AIS 3520LN-010 EMC TEST REPORT Document No.: 29050AA ACCELERATION SENSOR AIS 3520LN-010 Advanced International Sensors GmbH 22 May 2009 Page 1 of 11 Pages Table of Content 1 GENERAL INFORMATION...3 2 APPLIED DOCUMENTS...4

More information

Arbitrary/Function Waveform Generators 4075B Series

Arbitrary/Function Waveform Generators 4075B Series Data Sheet Arbitrary/Function Waveform Generators Point-by-Point Signal Integrity The Arbitrary/Function Waveform Generators are versatile high-performance single- and dual-channel arbitrary waveform generators

More information

Guide on Implementation of Requirements of the Common EPS

Guide on Implementation of Requirements of the Common EPS Annex III to Ref. Ares(2015)3438296-19/08/2015 MoU regarding Harmonisation of a Charging Capability for Mobile Phones, June 5th, 2009 Date: Dec 15, 2011 Foreword: Guide on Implementation of Requirements

More information

N. TEST TEST DESCRIPTION

N. TEST TEST DESCRIPTION Multi function system for testing substation equipment such as: current, voltage and power transformers, all type of protection relays, energy meters and transducers Primary injection testing capabilities

More information

1 of 6 03/12/2012 14:56 2012-12-03 HAMEG > Products > Accessories > Probes http://www.hameg.com/186.0.html P R O B E S H Z 5 6-2 * AC/ DC Current Clamps This AC/DC Current Probe is used to measure currents

More information

N acquisitions, all channels simultaneously, N is selectable from 4, 16, 64, and 128 Inputs

N acquisitions, all channels simultaneously, N is selectable from 4, 16, 64, and 128 Inputs With compliments All specifications apply to the TDS 200-Series Digital Real-Time Oscilloscope with a P2100 probe with the Attenuation switch set to 10X unless noted otherwise. To meet specifications,

More information

QA-ES III Electrosurgical Analyzer

QA-ES III Electrosurgical Analyzer QA-ES III Electrosurgical Analyzer Technical Data The QA-ES III Electrosurgical Analyzer simplifies testing to ensure the performance and safety of electrosurgical units. With generator output current

More information

2520 Pulsed Laser Diode Test System

2520 Pulsed Laser Diode Test System Simplifies laser diode LIV testing prior to packaging or active temperature control Integrated solution for in-process LIV production testing of laser diodes at the chip or bar level Sweep can be programmed

More information

Description, operating instructions and hardware specification of the HL Transverse balance measurement module (TBMM).

Description, operating instructions and hardware specification of the HL Transverse balance measurement module (TBMM). , operating instructions and hardware specification of the HL 8240 - Transverse balance measurement module (TBMM). The increasing use of telecom equipment in ultrafast applications has enhanced the need

More information

Tektronix: Products > AWG 2040 Arbitrary Waveform Generator

Tektronix: Products > AWG 2040 Arbitrary Waveform Generator Page 1 of 7 Arbitrary Waveform Generator AWG 2040 This product is no longer carried in our catalog. Features 1.024 GS/sec Clock Rate Provides up to 500 MHz Waveforms 1 MB Record Length (4 MB with Opt.

More information

SIGNAL GENERATORS. MG3633A 10 khz to 2700 MHz SYNTHESIZED SIGNAL GENERATOR GPIB

SIGNAL GENERATORS. MG3633A 10 khz to 2700 MHz SYNTHESIZED SIGNAL GENERATOR GPIB SYNTHESIZED SIGNAL GENERATOR MG3633A GPIB For Evaluating of Quasi-Microwaves and Measuring High-Performance Receivers The MG3633A has excellent resolution, switching speed, signal purity, and a high output

More information

AN ULTRA PORTABLE MARX GENERATOR-BASED SOLUTION FOR MIL STD 461 E/F RS-105 TESTING

AN ULTRA PORTABLE MARX GENERATOR-BASED SOLUTION FOR MIL STD 461 E/F RS-105 TESTING AN ULTRA PORTABLE MARX GENERATOR-BASED SOLUTION FOR MIL STD 461 E/F RS-105 TESTING J.R. Mayes, M.B. Lara, W.C. Nunnally, M.G. Mayes, and J. Dowden Applied Physical Electronics, L.C, PO Box 341149 Austin,

More information

~W~~~ Laboratory Accreditation Program

~W~~~ Laboratory Accreditation Program ~ ~.en) National Voluntary ~W~~~ Laboratory Accreditation Program SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 Dayton T. Brown, Inc. 1195 Church Street Bohemia, NY 11716 Ms. Mary Alice Der Aris Phone:

More information

Programmable Pulse Generators PSPL10050A, PSPL10060A, PSPL10070A Datasheet

Programmable Pulse Generators PSPL10050A, PSPL10060A, PSPL10070A Datasheet Programmable Pulse Generators PSPL10050A, PSPL10060A, PSPL10070A Datasheet Applications University education and research UWB signal source Semiconductor characterization Laser driver The PSPL10000 Series

More information

DS1102E, DS1052E, DS1102D, DS1052D

DS1102E, DS1052E, DS1102D, DS1052D RIGOL Data Sheet DS1000E, DS1000D Series Digital Oscilloscopes DS1102E, DS1052E, DS1102D, DS1052D Product Overview DS1000E, DS1000D series are kinds of economical digital oscilloscope with high-performance.

More information

R&S ENV216 Two-Line V-Network For disturbance voltage measurements on single-phase EUTs

R&S ENV216 Two-Line V-Network For disturbance voltage measurements on single-phase EUTs R&S ENV216 Two-Line V-Network For disturbance voltage measurements on single-phase EUTs Test & Measurement Data Sheet 03.00 R&S ENV216 Two-Line V-Network At a glance The R&S ENV216 two-line V-network meets

More information

Voltage Transient Emission Test

Voltage Transient Emission Test Manual For Operation AN 200 Series Voltage Transient Emission Test AN 200 AN 200B The AN 200 is used to evaluate automotive electrical and electronic components for conducted emissions of transients along

More information

Loop & Magnetic Field Coil

Loop & Magnetic Field Coil Model 6502 10 khz 30 MHz Model 6507 1 khz 30 MHz Model 6509 1 khz 30 MHz Model 7603 20 Hz >50 khz Model 7604 20 Hz 500 khz Model 7605 30 Hz >50 MHz Saturation Indicator Remote Monitor Option Quality Construction

More information

RIGOL Data Sheet. DS1000E, DS1000D Series Digital Oscilloscopes DS1102E, DS1052E, DS1102D, DS1052D. Product Overview. Applications. Easy to Use Design

RIGOL Data Sheet. DS1000E, DS1000D Series Digital Oscilloscopes DS1102E, DS1052E, DS1102D, DS1052D. Product Overview. Applications. Easy to Use Design RIGOL Data Sheet DS1000E, DS1000D Series Digital Oscilloscopes DS1102E, DS1052E, DS1102D, DS1052D Product Overview DS1000E, DS1000D series are kinds of economical digital oscilloscope with high-performance.

More information

DRTS-6. DRTS-6 has been designed to test: DRTS-6. Advanced Protection Relay Test Set and Measurement System

DRTS-6. DRTS-6 has been designed to test: DRTS-6. Advanced Protection Relay Test Set and Measurement System DRTS-6 Advanced Protection Relay Test Set and Measurement System MULTI-TASKING EQUIPMENT DESIGNED FOR TESTING PROTECTION RELAYS, ENERGY METERS, TRANSDUCERS POWERFUL AND LIGHTWEIGHT HIGH ACCURACY: BETTER

More information

500 khz / 1 MHz Precision LCR Meter Models 894 & 895

500 khz / 1 MHz Precision LCR Meter Models 894 & 895 Data Sheet 500 khz / 1 MHz Precision LCR Meter Industry-Leading Performance The 894 and 895 are high accuracy LCR meters capable of measuring inductance, capacitance, and resistance of components and materials

More information

FCC 15B Test Report. : BTv4.0 Dual Mode USB Dongle. Address : Thompson Ave. / Lenexa, Kansas / / USA

FCC 15B Test Report. : BTv4.0 Dual Mode USB Dongle. Address : Thompson Ave. / Lenexa, Kansas / / USA FCC 15B Test Report Equipment Model No. Brand Name Applicant : BTv4.0 Dual Mode USB Dongle : BT820 : Laird Technologies : Laird Technologies Address : 11160 Thompson Ave. / Lenexa, Kansas / 66219 / USA

More information

Exposure Level Tester ELT-400

Exposure Level Tester ELT-400 Safety Evaluation within a Magnetic Field Environment Exposure Level Tester ELT-400 Direct Evaluation of Field Exposure Compared to Major Standards (IEEE C95.6) Automatic Exposure Evaluation for Various

More information

CXE180 UNIVERSAL AMPLIFIER

CXE180 UNIVERSAL AMPLIFIER Kari Mäki 20.9.2012 1(6) CXE180 UNIVERSAL AMPLIFIER The CXE180 is a compact dual output amplifier. It has two gain modes in one product. Gain can be selected on the field according to wanted operation.

More information

CL55C CLICK ANALYSER The cost competitive, PC-driven, automatic, multi-channel discontinuous interference analyser

CL55C CLICK ANALYSER The cost competitive, PC-driven, automatic, multi-channel discontinuous interference analyser CL55C CLICK ANALYSER The cost competitive, PC-driven, automatic, multi-channel discontinuous interference analyser According to CISPR 14-1, Designed in compliance with CISPR 16-1, Advanced software for

More information

Immunity Testing for the CE Mark

Immunity Testing for the CE Mark Immunity Testing for the CE Mark Summary The European Union (EU) currently has 25 member countries with 2 additional countries to be added in 2007. The total population at that time will be nearly a half

More information

QA-ES III Electrosurgical Analyzer

QA-ES III Electrosurgical Analyzer QA-ES III Electrosurgical Analyzer Technical Data The QA-ES III Electrosurgical Analyzer simplifies testing to ensure the performance and safety of electrosurgical units. With generator output current

More information

FREQUENCY SYNTHESIZERS, SIGNAL GENERATORS

FREQUENCY SYNTHESIZERS, SIGNAL GENERATORS SYNTHESIZED SIGNAL GENERATOR MG3641A/MG3642A 12 khz to 1040/2080 MHz NEW New Anritsu synthesizer technology permits frequency to be set with a resolution of 0.01 Hz across the full frequency range. And

More information

Dual Channel Function/Arbitrary Waveform Generators 4050B Series

Dual Channel Function/Arbitrary Waveform Generators 4050B Series Data Sheet Dual Channel Function/Arbitrary Waveform Generators The Dual Channel Function/ Arbitrary Waveform Generators are capable of generating stable and precise sine, square, triangle, pulse, and arbitrary

More information

RF300 LARGE LOOP ANTENNA

RF300 LARGE LOOP ANTENNA LAPLACE INSTRUMENTS LTD RF300 LARGE LOOP ANTENNA USER GUIDE Serial Number 9072 Issue 5 May 2010 Page 1 INDEX Introduction 3 Packing list 3 Assembly 5 Calibration loop 12 Calibration 13 Operation 14 In

More information

CL55C CLICK ANALYSER The cost competitive, PC-driven, automatic, multi-channel discontinuous interference analyser

CL55C CLICK ANALYSER The cost competitive, PC-driven, automatic, multi-channel discontinuous interference analyser CL55C CLICK ANALYSER The cost competitive, PC-driven, automatic, multi-channel discontinuous interference analyser According to CISPR 14-1, Designed in compliance with CISPR 16-1, advanced software for

More information

R&S ZNC Vector Network Analyzer Specifications

R&S ZNC Vector Network Analyzer Specifications ZNC3_dat-sw_en_5214-5610-22_v0300_cover.indd 1 Data Sheet 03.00 Test & Measurement R&S ZNC Vector Network Analyzer Specifications 04.09.2012 13:39:47 CONTENTS Definitions... 3 Measurement range... 4 Measurement

More information

Arbitrary/Function Generator AFG1000 Series Datasheet

Arbitrary/Function Generator AFG1000 Series Datasheet Arbitrary/Function Generator AFG1000 Series Datasheet 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com Compatible with TekSmartLab

More information

Overview of EMC Regulations and Testing. Prof. Tzong-Lin Wu Department of Electrical Engineering National Taiwan University

Overview of EMC Regulations and Testing. Prof. Tzong-Lin Wu Department of Electrical Engineering National Taiwan University Overview of EMC Regulations and Testing Prof. Tzong-Lin Wu Department of Electrical Engineering National Taiwan University What is EMC Electro-Magnetic Compatibility ( 電磁相容 ) EMC EMI (Interference) Conducted

More information

PRODUCT DATA. 16-channel DeltaTron Conditioning Amplifiers Types 2694-A/B/C/D. Features and Uses

PRODUCT DATA. 16-channel DeltaTron Conditioning Amplifiers Types 2694-A/B/C/D. Features and Uses PRODUCT DATA 16-channel DeltaTron Conditioning Amplifiers s -A/B/C/D The family of 16-channel DeltaTron conditioning amplifiers comprises of general signal- conditioning amplifiers for voltage and DeltaTron

More information

INSTRUMENTS, INC. Model 2960AX Disciplined Quartz Frequency Standard 2960AX. Section Page Contents

INSTRUMENTS, INC. Model 2960AX Disciplined Quartz Frequency Standard 2960AX. Section Page Contents INSTRUMENTS, INC. Model 2960AX Disciplined Quartz Frequency Standard 2960AX Section Page Contents 1.0............................. 2......................... Description 2.0.............................

More information

Test and Measurement for EMC

Test and Measurement for EMC Test and Measurement for EMC Bogdan Adamczyk, Ph.D., in.c.e. Professor of Engineering Director of the Electromagnetic Compatibility Center Grand Valley State University, Michigan, USA Ottawa, Canada July

More information

Agilent E4428C ESG Analog Signal Generator

Agilent E4428C ESG Analog Signal Generator Migrate to the new Agilent MXG X-Series signal generator and generate true performance The new MXG exceeds the ESG s performance in every category - output power, phase noise, spurious, and low frequency

More information

ME7220A. Radar Test System (RTS) Target Simulation & Signal Analysis for Automotive Radar Exceptional Performance at an Affordable Price.

ME7220A. Radar Test System (RTS) Target Simulation & Signal Analysis for Automotive Radar Exceptional Performance at an Affordable Price. ME7220A Test System (RTS) 76 to 77 GHz Target Simulation & Signal Analysis for Automotive Exceptional Performance at an Affordable Price The Challenge The installation of collision warning and Adaptive

More information

RIGOL Data Sheet. DS1000E, DS1000D Series Digital Oscilloscopes DS1102E, DS1052E, DS1102D, DS1052D. Product Overview. Easy to Use Design.

RIGOL Data Sheet. DS1000E, DS1000D Series Digital Oscilloscopes DS1102E, DS1052E, DS1102D, DS1052D. Product Overview. Easy to Use Design. RIGOL Data Sheet DS1000E, DS1000D Series Digital Oscilloscopes DS1102E, DS1052E, DS1102D, DS1052D Product Overview The DS1000E, DS1000D series instruments are economical, high-performance digital oscilloscopes.

More information

Electricity Meter Test System

Electricity Meter Test System Component Tests Electricity Meter Test System System Overview.................... 3 Features & Benefits................... 4 Standards....................... 6 Application Options................... 7

More information

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 JEL LIMITED 2971 Nakabyo, Abiko-City Chiba-Prefecture, 270-1121, JAPAN Keiichiro Murata Phone: +81 4 7188 5333 Email: murata@jel.co.jp CALIBRATION Valid To:

More information

ELECTRIC FIELD PROBE ANTENNA MODEL PEF-10A. 20 Hz 1 MHz

ELECTRIC FIELD PROBE ANTENNA MODEL PEF-10A. 20 Hz 1 MHz INSTRUCTION MANUAL ELECTRIC FIELD PROBE ANTENNA MODEL PEF-10A 20 Hz 1 MHz INSTRUCTION MANUAL THIS INSTRUCTION MANUAL AND ITS ASSOCIATED INFORMATION IS PRO- PRIETARY. UNAUTHORIZED REPRO- DUCTION IS FORBIDDEN.

More information

TD 1000 PLUS. Secondary Injection Relay Test Set. Designed for testing relays and transducers

TD 1000 PLUS. Secondary Injection Relay Test Set. Designed for testing relays and transducers Secondary Injection Relay Test Set Designed for testing relays and transducers Two current outputs to test differential relays Convertible current and voltage generator With phase angle shifter Frequency

More information

Failing EMC testing? > 50% of products fail EMC testing first time around

Failing EMC testing? > 50% of products fail EMC testing first time around Failing EMC testing? > 50% of products fail EMC testing first time around Situation An engineer of a small or medium size enterprise usually has to rely on his experience and on best practice methods in

More information

Automotive Scope/GMM/OBD II Code Reader

Automotive Scope/GMM/OBD II Code Reader Finest 1006 Automotive Scope/GMM/OBD II Code Reader Automotive On-board diagnostic systems of thesedays have gone a long way toward helping you locate a problem. But those systems aren't perfect and they

More information

Electromagnetic Compatibility Test Report

Electromagnetic Compatibility Test Report Electromagnetic Compatibility Test Report Test Report No: SAE 140711 Issued on: July 14, 2011 Product Name Transceiver for Antenna Tag Identification Model: Ideal Atmega 358/200 khz Tested According to

More information

DC Electronic Loads 8500 Series

DC Electronic Loads 8500 Series Data Sheet DC Electronic Loads 2400W 600 W - 1200 W 300 W Versatile & Economical DC Electronic Loads The 8500 series Programmable DC Electronic Loads can be used for testing and evaluating a variety of

More information

EFFECT OF SHIELDING ON CABLE RF INGRESS MEASUREMENTS LARRY COHEN

EFFECT OF SHIELDING ON CABLE RF INGRESS MEASUREMENTS LARRY COHEN EFFECT OF SHIELDING ON CABLE RF INGRESS MEASUREMENTS LARRY COHEN OVERVIEW Purpose: Examine the common-mode and differential RF ingress levels of 4-pair UTP, F/UTP, and F/FTP cables at an (RJ45) MDI port

More information

TEST SUMMARY Seite 2 von 19. Prüfbericht - Nr.: Test Report No.:

TEST SUMMARY Seite 2 von 19. Prüfbericht - Nr.: Test Report No.: 10050333 001 Seite 2 von 19 Page 2 of 19 TEST SUMMARY 5.1 CONDUCTED EMISSION PER SECTION 15.107, FCC 47 CFR PART 15 SUBPART B RESULT: Pass 5.2 RADIATED EMISSION PER SECTION 15.109, FCC 47 CFR PART 15 SUBPART

More information

Technical Specification

Technical Specification LARGEST RANGE OF IMPULSE TESTERS UP TO 100KV/100KA Technical Specification E-MIG1203CWG revised: 22. June 2003 1 MIG Tester Type MIG1203CWG 1 MIG Tester Type MIG1203CWG 1 1.1 Introduction 1 2 General 2

More information

Reducing Uncertainty in EMC Measurements

Reducing Uncertainty in EMC Measurements Reducing Uncertainty in EMC Measurements Uncertainty In general, a standardized EMC test must be developed such that reproducible results are obtained if different parties perform the same test with the

More information

Shenzhen CTL Electromagnetic Technology Co., Ltd. Tel: Fax: TEST REPORT

Shenzhen CTL Electromagnetic Technology Co., Ltd. Tel: Fax: TEST REPORT Shenzhen CTL Electromagnetic Technology Co., Ltd. Tel: +86-755-89486194 Fax: +86-755-89486194-805 TEST REPORT EN 55014-1 / EN 55014-2 Electromagnetic compatibility Requirements for household appliances,

More information

Localizer provides signal generation over the Localizer band of to MHz with 90 Hz and 150 Hz tones, amplitude modulated

Localizer provides signal generation over the Localizer band of to MHz with 90 Hz and 150 Hz tones, amplitude modulated The IFR 4000 verifies the operation and installation of ILS, VOR and Marker Beacon receivers and VHF/UHF AM/FM and HF AM/SSB transceivers. The IFR 4000, with its lightweight size (under 8 lbs.), long run

More information

Overcurrent Protection / 7SJ45

Overcurrent Protection / 7SJ45 Overcurrent Protection / SJ SIPROTEC easy SJ numerical overcurrent protection relay powered by CTs Fig. / Description SIPROTEC easy SJ numerical overcurrent protection relay powered by current transformers

More information

Bulk Current Injection Probe Test Procedure

Bulk Current Injection Probe Test Procedure Bulk Current Injection Probe Test Procedure 1 TABLE OF CONTENTS INTRODUCTION 3 GENERAL INFORMATION 4 TEST METHODS 6 SAFETY 8 FIGURES 9 FORMULAS 12 MAINTENANCE 13 WARRANTY 14 2 INTRODUCTION CURRENT PROBE

More information

HMC-T2220B. Portable & Battery Operated! Portable Synthesized Signal Generator, 10 MHz to 20 GHz. Instrumentation Product Support at

HMC-T2220B. Portable & Battery Operated! Portable Synthesized Signal Generator, 10 MHz to 20 GHz. Instrumentation Product Support at Portable, 10 MHz to 20 GHz Portable & Battery Operated! 78-250-3343 tel 78-250-3373 fax Battery Operated 20 GHz Signal Generator! The is a battery powered, portable test equipment solution designed to

More information

Signal Generators SMY

Signal Generators SMY NEW up to 25 dbm RF sweep 9 khz to 1040/2080 MHz Signal Generators SMY Versatility and low cost can go hand in hand Frequency resolution 1 Hz Level range 140 to +19 dbm, overrange up to 25 dbm (option)

More information

Nemko Canada Inc., 303 River Road, R.R. 5, Ottawa, Ontario, Canada, K1V 1H2

Nemko Canada Inc., 303 River Road, R.R. 5, Ottawa, Ontario, Canada, K1V 1H2 www.nemko.com Nemko Canada Inc., 303 River Road, R.R. 5, Ottawa, Ontario, Canada, K1V 1H2 Report Number: Product Marketing Name: 123766-1TRFEMC Paycheck 4 Thermal Ticket Printer Test Specification: FCC

More information

Fluke Norma 4000/5000

Fluke Norma 4000/5000 Fluke Norma 4000/5000 High Precision Power Analyzers Reliable, highly accurate measurements for the test & development of power electronics Technical Data Compact Fluke Norma Series power analyzers include

More information

CXE180 UNIVERSAL AMPLIFIER

CXE180 UNIVERSAL AMPLIFIER Kari Mäki 14.6.2010 1(5) CXE180 UNIVERSAL AMPLIFIER The CXE180 is a compact dual output amplifier. It has two gain modes in one product. Gain can be selected on the field according to wanted operation.

More information

V1.3. TBLC08 50mH AC-LISN TBLC08

V1.3. TBLC08 50mH AC-LISN TBLC08 V1.3 TBLC08 The TBLC08 is a Line Impedance Stabilization Network for the measurement of line-conducted interference within the range of 9kHz to 30MHz, according to the CISPR16 standard. The device is designed

More information

R&S ZNBT8 Vector Network Analyzer Specifications

R&S ZNBT8 Vector Network Analyzer Specifications E stablished 1981 Advanced Test Equipment Rentals www.atecorp.com 800-404-ATEC (2832) ZNBT8_dat-sw_en_3606-9727-22_v0200_cover.indd 1 Data Sheet 02.00 Test & Measurement R&S ZNBT8 Vector Network Analyzer

More information

R&S OSP Open Switch and Control Platform Specifications

R&S OSP Open Switch and Control Platform Specifications R&S OSP Open Switch and Control Platform Specifications Data Sheet Version 15.00 CONTENTS Definitions... 4 Introduction... 5 R&S OSP120... 5 R&S OSP130... 5 R&S OSP150... 5 R&S OSP-B200S2... 5 General

More information

Fluke 8845A/8846A Digital Multimeters Extended Specifications

Fluke 8845A/8846A Digital Multimeters Extended Specifications Fluke 8845A/8846A Digital Multimeters Extended Specifications The Fluke 8845A and 8846A 6.5 digit precision multimeters have the precision and versatility to handle your most demanding measurements, on

More information

CONFORMANCE TEST REPORT FOR EN /-6

CONFORMANCE TEST REPORT FOR EN /-6 CONFORMANCE TEST REPORT FOR EN 301489-1/-6 Client: Product: Model: Manufacturer/supplier: Aztech Systems Limited DECT Phone H315-S1 (FP) Aztech Systems Limited Date test item received: 2006/05/09 Date

More information