2 FIJI/Image J for Beginners Fundamentals of digital imaging The Digital Image (pixels, bit depth) Image Acquisition (dynamic range, resolution, sampling,) Basic Rules of Digital Images (data handling & image ethics) Image Presentation (guidelines, colour sensitivity/blindness & printing) Applications (Demonstrations & hands on sessions) Image Import Image manipulation Annotation Visualisation & presentation of 2D data Visualisation & presentation of 3D data Visualisation & presentation of timelapse data

3 The Digital Image Dr Paul McMillan Biological Optical Microscopy Platform

4 Pixels Your image is recorded as a numerical array of pixels Pixel has its defined - size (sampling resolution) - grey level (bit depth) 100nm 100nm

5 Bit depth 1 bit 2 grey levels bit 4 grey levels bit 8 grey levels bit 16 grey levels 2 4

6 Bit depth intensity coding bit 16bit

7 Bit depth Example images 1-bit 2-bit 3-bit 4-bit 8-bit

8 Bit depth bit 2 bit 3-bit 4-bit 8-bit 50 0

9 Bit depth - equipment Bit depth Grey levels Use BOMP equipment 1 2 Binary masks for image analysis Late night reading NA Scientific cameras, PMT, GaAsP FIJI, Imaris, Metamorph, Volocity PMT, GaAsP (LSM800) Scientific cameras, PMT, HyD PMT, HyD (Leica SP8) 15 32,768 Scientific cameras scmos (OMX) 16 65,536 Scientific cameras, PMT, GaAsP 32 4,294,967,296 FLIM & other high end techniques Visualisation = 8 bit, quantification = 12 or 16 bit PMT, GaAsP (LSM800)

10 Image acquisition Dr Paul McMillan Biological Optical Microscopy Platform

11 Intensity graph Intensity distribution of image x axis = intensity Y axis = # of pixels with that intensity

12 Intensity graph All image modification must be ETHICAL Can adjust Minimum & Maximum position DO NOT adjust gamma (non-linear) Be descriptive of modifications in methods

13 Resolution & Sampling VECTOR RASTER

14 Resolution & Sampling Frame size 3x3 5x5 10x10 20x20 300x300 Pixel size 1/3 =

15 Nyquist rate In order to convert analogue signal to digital, signal needs to be sampled at least 2.3 times of half cycle (from top to bottom) 0.83x 1.3x 2.3x 10x Undersampled Just enough oversampled Image courtesy of Cameron Nowell

16 Nyquist-Shannon sampling Pixel dimensions = Theoretical axial resolution/2.3 Magnification NA Type 405 nm 488 nm 561 nm 633 nm 5 x 0.1 Air x 0.3 Air x 0.5 Air x 1.25 Oil x 1.4 Oil x 1.4 Oil Only use this if you need this resolution

17 Get the best representative image Best representation of what you are seeing on the microscope Crap in Crap out Any staining can be positive or negative depending on your imaging setting - No offset on your raw data - Set range with your (+)/(-) control sample - Same setting between samples - Pilot analysis before/during imaging

18 Basic Rules of Digital Imaging Dr Paul McMillan Biological Optical Microscopy Platform

19 Basic rules of digital data 1. SAVE Always save as the raw file extension.lif or.lei (Leica).lsm or.czi (Zeiss).oif or.oib (Olympus).dv (Deltavision) Raw file Image metadata Metadata contains all image parameters Laser wavelength Light path settings Objective lens / NA Pinhole Frame Size Voxel dimension Gain/offset Bit Depth Scan speed Average

20 Basic rules of digital data 2. Export Raw file Image metadata TIF JPG, GIF, PNG Keeps original information for data analysis Compressed, lossy for PowerPoint only

21 Basic rules of digital data 3. Modification Raw file Image metadata Raw file Image metadata Never process/modify on the raw files. Make a copy to process. 4. Backup Always double back up your data (NHMRC guidelines) Exported Image Exported modified Image Exported Image Exported modified Image Never use the Microscope computer to store your data Data Graphs Modification details Data Graphs Modification details

22 Image = scientific data Image beautification = data manipulation oops, I was not aware of this sorry, but I thought it was okay to make the images clearer

23 Modification on a specific feature Original image Manipulated image -The gold particles have been enhanced -Background dot has been removed Image from Mike Rossner, and Kenneth M. Yamada J Cell Biol 2004;166:11-15

24 Modification on a specific feature Manipulated image? Manipulation revealed By contrast adjustment Cells from other image has been added Image from Mike Rossner, and Kenneth M. Yamada J Cell Biol 2004;166:11-15

25 Modification on a specific feature Original image Manipulated image live with it since it isn t too bad crop it out resection the block and take a new photomicrograph without the tissue fold Image from

26 Modification on the background Original image Manipulated image Acceptable only if - No change occurred in the actual tissue - A statement is made in the figure legend Background Shading in one corner cleaned up Image from

27 Modification on the background Original image Manipulated image uneven illumination & brown fat has been erased NOT Acceptable because -large degree of background alteration (even if it is clarified and the interested area is not modified) Image from

28 Modification to whole image Original image Generally acceptable Misrepresented

29 Modification to whole image (-)Control (+)control sample black GFP expression on the sample looks similar to (+)control exposure and contrast to the maximum Images have not been processed identically Completely black colour balance differs Image from Mike Blatt, and Cathie Martin Plant Physiol. 2013;163:3-4

30 Image presentation Dr Paul McMillan Biological Optical Microscopy Platform

31 Data presentation guidelines Cell Instructions to authors Any alterations should be applied to the entire image. Clearly explain all alterations in the figure legend. Only compare data that are appropriate to compare (e.g., data from the same experiment, acquired the same way). Individual images should not be used in multiple figures (unless the figures describe different aspects of the same experiment) My 5 cents worth Be aware of colour sensitivity & colour blindness Be aware of printing issues

32 Colour (Most) Fluorescence detectors are monochrome Images are usually grayscale Converted to colour using Look Up Tables (LUTs) Blue Green Red 0 255

33 Colour sensitivity

34 RGB RED GREEN BLUE

35 RGB vs CMYK

36 Colours RGB vs CMYK

37 Use grayscale for panels

Bi/BE 227 Winter Assignment #3. Adding the third dimension: 3D Confocal Imaging

Bi/BE 227 Winter Assignment #3. Adding the third dimension: 3D Confocal Imaging Bi/BE 227 Winter 2016 Assignment #3 Adding the third dimension: 3D Confocal Imaging Schedule: Jan 20: Assignment Jan 20-Feb 8: Work on assignment Feb 10: Student PowerPoint presentations. Goals for this

More information

LEICA TCS SP5 AOBS TANDEM USER MANUAL

LEICA TCS SP5 AOBS TANDEM USER MANUAL LEICA TCS SP5 AOBS TANDEM USER MANUAL STARTING THE SYSTEM...2 THE LAS AF SOFTWARE...3 THE «ACQUIRE» MENU...5 CHOOSE AND CREATE A SETTING...6 THE CONTROL PANEL...8 THE DMI6000B MICROSCOPE...10 ACQUIRE ONE

More information

Light Microscopy for Biomedical Research

Light Microscopy for Biomedical Research Light Microscopy for Biomedical Research Tuesday 4:30 PM Quantification & Digital Images Michael Hooker Microscopy Facility Michael Chua microscopy@unc.edu 843-3268 6007 Thurston Bowles http://microscopy.unc.edu/lmbr

More information

LSM 710 Confocal Microscope Standard Operation Protocol

LSM 710 Confocal Microscope Standard Operation Protocol LSM 710 Confocal Microscope Standard Operation Protocol Basic Operation Turning on the system 1. Switch on Main power switch 2. Switch on System / PC power button 3. Switch on Components power button 4.

More information

(Quantitative Imaging for) Colocalisation Analysis

(Quantitative Imaging for) Colocalisation Analysis (Quantitative Imaging for) Colocalisation Analysis or Why Colour Merge / Overlay Images are EVIL! Special course for DIGS-BB PhD program What is an Image anyway..? An image is a representation of reality

More information

Boulevard du Temple Daguerrotype (Paris,1838) a busy street? Nyquist sampling for movement

Boulevard du Temple Daguerrotype (Paris,1838) a busy street? Nyquist sampling for movement Boulevard du Temple Daguerrotype (Paris,1838) a busy street? Nyquist sampling for movement CONFOCAL MICROSCOPY BioVis Uppsala, 2017 Jeremy Adler Matyas Molnar Dirk Pacholsky Widefield & Confocal Microscopy

More information

ZEISS LSM 710 CONFOCAL MICROSCOPE USER MANUAL

ZEISS LSM 710 CONFOCAL MICROSCOPE USER MANUAL ZEISS LSM 710 CONFOCAL MICROSCOPE USER MANUAL START THE SYSTEM... 2 START ZEN SOFTWARE... 3 SET THE TEMPERATURE AND THE CO2 CONTROLLERS... OBSERVATION AT OCULARS... 5 STATIF PRESENTATION... 6 ACQUIRE ONE

More information

Practical work no. 3: Confocal Live Cell Microscopy

Practical work no. 3: Confocal Live Cell Microscopy Practical work no. 3: Confocal Live Cell Microscopy Course Instructor: Mikko Liljeström (MIU) 1 Background Confocal microscopy: The main idea behind confocality is that it suppresses the signal outside

More information

Operation Guide for the Leica SP2 Confocal Microscope Bio-Imaging Facility Hunter College October 2009

Operation Guide for the Leica SP2 Confocal Microscope Bio-Imaging Facility Hunter College October 2009 Operation Guide for the Leica SP2 Confocal Microscope Bio-Imaging Facility Hunter College October 2009 Introduction of Fluoresence Confocal Microscopy The first confocal microscope was invented by Princeton

More information

LSM 780 Confocal Microscope Standard Operation Protocol

LSM 780 Confocal Microscope Standard Operation Protocol LSM 780 Confocal Microscope Standard Operation Protocol Basic Operation Turning on the system 1. Sign on log sheet according to Actual start time 2. Check Compressed Air supply for the air table 3. Switch

More information

1 Co Localization and Working flow with the lsm700

1 Co Localization and Working flow with the lsm700 1 Co Localization and Working flow with the lsm700 Samples -1 slide = mousse intestine, Dapi / Ki 67 with Cy3/ BrDU with alexa 488. -1 slide = mousse intestine, Dapi / Ki 67 with Cy3/ no BrDU (but with

More information

Megapixel FLIM with bh TCSPC Modules

Megapixel FLIM with bh TCSPC Modules Megapixel FLIM with bh TCSPC Modules The New SPCM 64-bit Software Abstract: Becker & Hickl have recently introduced version 9.60 of their SPCM TCSPC data acquisition software. SPCM version 9.60 not only

More information

JCB Feature. What s in a picture? The temptation of image manipulation. The Journal of Cell Biology

JCB Feature. What s in a picture? The temptation of image manipulation. The Journal of Cell Biology JCB Feature What s in a picture? The temptation of image manipulation Mike Rossner 1 and Kenneth M. Yamada 2 1 Managing Editor, The Journal of Cell Biology 2 Editor, The Journal of Cell Biology, and the

More information

SECTION I - CHAPTER 2 DIGITAL IMAGING PROCESSING CONCEPTS

SECTION I - CHAPTER 2 DIGITAL IMAGING PROCESSING CONCEPTS RADT 3463 - COMPUTERIZED IMAGING Section I: Chapter 2 RADT 3463 Computerized Imaging 1 SECTION I - CHAPTER 2 DIGITAL IMAGING PROCESSING CONCEPTS RADT 3463 COMPUTERIZED IMAGING Section I: Chapter 2 RADT

More information

Title: Leica SP5 Confocal User Manual

Title: Leica SP5 Confocal User Manual Title: Leica SP5 Confocal User Manual Date of first issue: 23/10/2015 Date of review: Version: Admin For assistance or to report an issue Office: CG07 or 05 Email: Igmm-imaginghelpdesk@igmm.ed.ac.uk Website:

More information

User manual for Olympus SD-OSR spinning disk confocal microscope

User manual for Olympus SD-OSR spinning disk confocal microscope User manual for Olympus SD-OSR spinning disk confocal microscope Ved Prakash, PhD. Research imaging specialist Imaging & histology core University of Texas, Dallas ved.prakash@utdallas.edu Once you open

More information

Supplemental Figure 1: Histogram of 63x Objective Lens z axis Calculated Resolutions. Results from the MetroloJ z axis fits for 5 beads from each

Supplemental Figure 1: Histogram of 63x Objective Lens z axis Calculated Resolutions. Results from the MetroloJ z axis fits for 5 beads from each Supplemental Figure 1: Histogram of 63x Objective Lens z axis Calculated Resolutions. Results from the MetroloJ z axis fits for 5 beads from each lens with a 1 Airy unit pinhole setting. Many water lenses

More information

Image Capture TOTALLAB

Image Capture TOTALLAB 1 Introduction In order for image analysis to be performed on a gel or Western blot, it must first be converted into digital data. Good image capture is critical to guarantee optimal performance of automated

More information

Image Processing in scientific publications

Image Processing in scientific publications Image Processing in scientific publications Claudia Dumrese Center for Microscopy and Image Analysis Image acquisition - CCD Camera Chip 1 Image acquisition - CCD Camera Chip - pixel + Polysilicon Gate

More information

CONFOCAL MICROSCOPE (Zeiss LSM 510 META v4.2)

CONFOCAL MICROSCOPE (Zeiss LSM 510 META v4.2) Wellcome Trust Centre for Human Genetics Molecular Cytogenetics and Microscopy Core CONFOCAL MICROSCOPE (Zeiss LSM 510 META v4.2) 1) STARTING THE SYSTEM Abridged INSTRUCTIONS Switch on the mercury bulb

More information

Dynamic Phase-Shifting Microscopy Tracks Living Cells

Dynamic Phase-Shifting Microscopy Tracks Living Cells from photonics.com: 04/01/2012 http://www.photonics.com/article.aspx?aid=50654 Dynamic Phase-Shifting Microscopy Tracks Living Cells Dr. Katherine Creath, Goldie Goldstein and Mike Zecchino, 4D Technology

More information

Introduction to Image Analysis with

Introduction to Image Analysis with Introduction to Image Analysis with PLEASE ENSURE FIJI IS INSTALLED CORRECTLY! WHAT DO WE HOPE TO ACHIEVE? Specifically, the workshop will cover the following topics: 1. Opening images with Bioformats

More information

Microscope Confocal Sp2 Upright.

Microscope Confocal Sp2 Upright. Microscope Confocal Sp2 Upright. Welcome to the Leica Sp2 Confocal Upright tutorial. Before using the Sp2 Invert, You will need to put down your name on the reservation system = http://svintranet.epfl.ch/index.php?optio

More information

Leica Sp5 II Confocal User Guide

Leica Sp5 II Confocal User Guide Leica Sp5 II Confocal User Guide Turning on the Confocal System (instructions are posted in the room) 1. Turn on Laser Power Button 2. Turn Key to On position 3. Turn on Scanner Power Button 4. Turn on

More information

Leica TCS SP8 Quick Start Guide

Leica TCS SP8 Quick Start Guide Leica TCS SP8 Quick Start Guide Leica TCS SP8 System Overview Start-Up Procedure 1. Turn on the CTR Control Box, Fluorescent Light for the microscope stand. 2. Turn on the Scanner Power (1) on the front

More information

Improving Image Quality on the UACC Leica SP5 confocal

Improving Image Quality on the UACC Leica SP5 confocal Improving Image Quality on the UACC Leica SP5 confocal Douglas Cromey, MS (UACC TACMASR Microscopy) Some days it is difficult to come up with a brightly stained sample. This document contains some strategies

More information

What is a digital image?

What is a digital image? Chapter 4 What is a digital image? 4.1 How is the image represented by the computer? Pixels Images can have 2 or 3 spacial dimensions, a time dimensions and a number of colour-channels. An image is a rectilinear

More information

MIF ZEISS LSM510 CONFOCAL USER PROTOCOL

MIF ZEISS LSM510 CONFOCAL USER PROTOCOL MIF ZEISS LSM510 CONFOCAL USER PROTOCOL START-UP Turn on the Mercury Bulb Power Supply (if needed). Power-on the Control Box. Turn on the computer. Open the LSM 510 software. Choose Scan New Images and

More information

Supplemental Method Information Zeiss LSM710

Supplemental Method Information Zeiss LSM710 Supplemental Method Information Zeiss LSM710 1 Under the Light Path window set up the confocal for imaging a green dye (Alexa488-EGFP). For example, set up the light path as shown here using the 488 nm

More information

Images and Graphics. 4. Images and Graphics - Copyright Denis Hamelin - Ryerson University

Images and Graphics. 4. Images and Graphics - Copyright Denis Hamelin - Ryerson University Images and Graphics Images and Graphics Graphics and images are non-textual information that can be displayed and printed. Graphics (vector graphics) are an assemblage of lines, curves or circles with

More information

Creating Digital Artwork

Creating Digital Artwork 5Steps to Creating Digital Artwork (For more detailed instructions, please click here) Introduction to Digital Artwork Authors often choose to include digital artwork as part of a submission to a medical

More information

The BIOS in many personal computers stores the date and time in BCD. M-Mushtaq Hussain

The BIOS in many personal computers stores the date and time in BCD. M-Mushtaq Hussain Practical applications of BCD The BIOS in many personal computers stores the date and time in BCD Images How data for a bitmapped image is encoded? A bitmap images take the form of an array, where the

More information

CATEGORY SKILL SET REF. TASK ITEM

CATEGORY SKILL SET REF. TASK ITEM ECDL / ICDL Image Editing This module sets out essential concepts and skills relating to the ability to understand the main concepts underlying digital images and to use an image editing application to

More information

Technology Note ZEISS LSM 880 with Airyscan

Technology Note ZEISS LSM 880 with Airyscan Technology Note ZEISS LSM 880 with Airyscan Introducing the Fast Acquisition Mode ZEISS LSM 880 with Airyscan Introducing the Fast Acquisition Mode Author: Dr. Annette Bergter Carl Zeiss Microscopy GmbH,

More information

Digital Image Creation and Development

Digital Image Creation and Development Unit 37: Digital Image Creation and Development Unit code: Y/601/6721 QCF Level 5: BTEC Higher National Credit value: 15 Aim This unit aims to develop skills and understanding in sourcing, creating, developing

More information

Why and How? Daniel Gitler Dept. of Physiology Ben-Gurion University of the Negev. Microscopy course, Michmoret Dec 2005

Why and How? Daniel Gitler Dept. of Physiology Ben-Gurion University of the Negev. Microscopy course, Michmoret Dec 2005 Why and How? Daniel Gitler Dept. of Physiology Ben-Gurion University of the Negev Why use confocal microscopy? Principles of the laser scanning confocal microscope. Image resolution. Manipulating the

More information

Nikon. King s College London. Imaging Centre. N-SIM guide NIKON IMAGING KING S COLLEGE LONDON

Nikon. King s College London. Imaging Centre. N-SIM guide NIKON IMAGING KING S COLLEGE LONDON N-SIM guide NIKON IMAGING CENTRE @ KING S COLLEGE LONDON Starting-up / Shut-down The NSIM hardware is calibrated after system warm-up occurs. It is recommended that you turn-on the system for at least

More information

Astronomy and Image Processing. Many thanks to Professor Kate Whitaker in the physics department for her help

Astronomy and Image Processing. Many thanks to Professor Kate Whitaker in the physics department for her help Astronomy and Image Processing Many thanks to Professor Kate Whitaker in the physics department for her help What is an image? An image is an array, or a matrix, of square pixels (picture elements) arranged

More information

Topic 04 What is a digital image?

Topic 04 What is a digital image? Topic 04 What is a digital image? Exercise 4.1 How is the image represented by the computer - Pixels Images can have 2 or 3 spacial dimensions, a time dimensions and a number of colour-channels. An image

More information

Leica TCS SP8 Quick Start Guide

Leica TCS SP8 Quick Start Guide Leica TCS SP8 Quick Start Guide Leica TCS SP8 System Overview Start-Up Procedure 1. Turn on the CTR Control Box, EL6000 fluorescent light source for the microscope stand. 2. Turn on the Scanner Power

More information

Fundamentals of Light Microscopy II: Fluorescence, Deconvolution, Confocal, Multiphoton, Spectral microscopy. Integrated Microscopy Course

Fundamentals of Light Microscopy II: Fluorescence, Deconvolution, Confocal, Multiphoton, Spectral microscopy. Integrated Microscopy Course Fundamentals of Light Microscopy II: Fluorescence, Deconvolution, Confocal, Multiphoton, Spectral microscopy Integrated Microscopy Course Review Lecture 1: Microscopy Basics Light train Kohler illumination*

More information

Leica SP8 TCS Users Manual

Leica SP8 TCS Users Manual Version : 07/08/0 Leica SP8 TCS Users Manual Start up:. Turn the PC Microscope, Scanner Power, Laser Power, and the Laser Emission key to on (bottom right of desk).. Turn on the fluorescent lamp (top left

More information

NanoMet Nanoparticle Diameter Example Report

NanoMet Nanoparticle Diameter Example Report NanoMet Nanoparticle Diameter Example Report For: Customer Name Address Contact Person Analysis runs performed on [DATE] by [USER] FullScaleNANO, Inc. 400 Capital Circle SE, Suite 18227 Tallahassee, FL

More information

Characterization Microscope Nikon LV150

Characterization Microscope Nikon LV150 Characterization Microscope Nikon LV150 Figure 1: Microscope Nikon LV150 Introduction This upright optical microscope is designed for investigating up to 150 mm (6 inch) semiconductor wafers but can also

More information

Digital photo sizes and file formats

Digital photo sizes and file formats Digital photo sizes and file formats What the size means pixels, bytes & dpi How colour affects size File formats and sizes - compression Why you might need to change the size How to change size For Tynemouth

More information

Q A bitmap file contains the binary on the left below. 1 is white and 0 is black. Colour in each of the squares. What is the letter that is reve

Q A bitmap file contains the binary on the left below. 1 is white and 0 is black. Colour in each of the squares. What is the letter that is reve R 25 Images and Pixels - Reading Images need to be stored and processed using binary. The simplest image format is for an image to be stored as a bitmap image. Bitmap images are made up of picture elements

More information

CHAPTER 3 I M A G E S

CHAPTER 3 I M A G E S CHAPTER 3 I M A G E S OBJECTIVES Discuss the various factors that apply to the use of images in multimedia. Describe the capabilities and limitations of bitmap images. Describe the capabilities and limitations

More information

The Zeiss AiryScan System, Confocal Four.

The Zeiss AiryScan System, Confocal Four. The Zeiss AiryScan System, Confocal Four. Overview. The Zeiss AiryScan module is a segmented, radially stacked GaASP detector and collector system designed to subsample the airy disk of a point emission

More information

FLUORESCENCE MICROSCOPY. Matyas Molnar and Dirk Pacholsky

FLUORESCENCE MICROSCOPY. Matyas Molnar and Dirk Pacholsky FLUORESCENCE MICROSCOPY Matyas Molnar and Dirk Pacholsky 1 The human eye perceives app. 400-700 nm; best at around 500 nm (green) Has a general resolution down to150-300 μm (human hair: 40-250 μm) We need

More information

SCANNING GUIDELINES Peter Thompson (rev. 9/21/02) OVERVIEW

SCANNING GUIDELINES Peter Thompson (rev. 9/21/02) OVERVIEW SCANNING GUIDELINES Peter Thompson (rev. 9/21/02) OVERVIEW WHAT S A SCANNER? A machine that lets you input an image into your and save it as a digital file to be enhanced or altered by image editing software

More information

Things to check before start-up.

Things to check before start-up. Byeong Cha Page 1 11/24/2009 Manual for Leica SP2 Confocal Microscope Enter you name, the date, the time, and the account number in the user log book. Things to check before start-up. Make sure that your

More information

Color, Resolution, & Other Image Essentials

Color, Resolution, & Other Image Essentials www.gilbertconsulting.com blog.gilbertconsulting.com kgilbert@gilbertconsulting.com Twitter: @gilbertconsult lynda.com/keithgilbert Every Photoshop image consists of three specific attributes: image resolution,

More information

Dr. Shahanawaj Ahamad. Dr. S.Ahamad, SWE-423, Unit-06

Dr. Shahanawaj Ahamad. Dr. S.Ahamad, SWE-423, Unit-06 Dr. Shahanawaj Ahamad 1 Outline: Basic concepts underlying Images Popular Image File formats Human perception of color Various Color Models in use and the idea behind them 2 Pixels -- picture elements

More information

We attempted to separate the two dyes by acquiring images using a single excitation wavelength and just two emission wavelengths.

We attempted to separate the two dyes by acquiring images using a single excitation wavelength and just two emission wavelengths. TN437: Spectral Separation of monochrome images using Volocity 4.0 Introduction Spectral Separation is a technique that allows the user to separate images containing data from more than one fluorochrome

More information

contents TABLE OF The SECOM platform Applications - sections Applications - whole cells Features Integrated workflow Automated overlay

contents TABLE OF The SECOM platform Applications - sections Applications - whole cells Features Integrated workflow Automated overlay S E C O M TABLE OF contents The SECOM platform 4 Applications - sections 5 Applications - whole cells 8 Features 9 Integrated workflow 12 Automated overlay ODEMIS - integrated software Specifications 13

More information

Digital Imaging and Image Editing

Digital Imaging and Image Editing Digital Imaging and Image Editing A digital image is a representation of a twodimensional image as a finite set of digital values, called picture elements or pixels. The digital image contains a fixed

More information

Diskovery Spinning Disk Guide

Diskovery Spinning Disk Guide Diskovery Spinning Disk Guide qbi.microscopy@uq.edu.au Getting started The microscope and its peripherals (Fig. 1a) should always be turned on, but if they are not, turn them on in the following way: 1.

More information

Leica SP8 Resonant Confocal. Quick-Start Guide

Leica SP8 Resonant Confocal. Quick-Start Guide Leica SP8 Resonant Confocal Quick-Start Guide Contents Start-up Preparing for Imaging Part 1 On the scope Part 2 Software interface Part 3 Heat & CO2 incubation Part 4 Other hardware options Shut-down

More information

UNIVERSITY OF CALICUT INTRODUCTION TO MULTIMEDIA QUESTION BANK

UNIVERSITY OF CALICUT INTRODUCTION TO MULTIMEDIA QUESTION BANK UNIVERSITY OF CALICUT SCHOOL OF DISTANCE EDUCATION BGDA (UG SDE) II SEMESTER COMPLEMENTARY COURSE INTRODUCTION TO MULTIMEDIA QUESTION BANK BGDA Page 1 1. Which file format contain photorealistic images

More information

REMEMBER: You have 5GB of disk space on this microscope. Check before you start if you have room for your experiment. If not delete your old data.

REMEMBER: You have 5GB of disk space on this microscope. Check before you start if you have room for your experiment. If not delete your old data. 1 Use of the Zeiss LSM 510 Inverted Firstly please be aware that this microscope should be treated with respect and care at all times. Rules of use: This Microscope can only be used by Masters by Research

More information

GIMP Tutorial. v2.2. Boo Virk.

GIMP Tutorial. v2.2. Boo Virk. GIMP Tutorial v2.2 Boo Virk boo.virk@babraham.ac.uk What is GIMP GNU Image Manipulation Program Bitmap Graphics Editor Open Source Cross Platform Not for Vector editing www.gimp.org Vector vs Bitmap GIMP

More information

Operating Instructions for Zeiss LSM 510

Operating Instructions for Zeiss LSM 510 Operating Instructions for Zeiss LSM 510 Location: GNL 6.312q (BSL3) Questions? Contact: Maxim Ivannikov, maivanni@utmb.edu 1 Attend A Complementary Training Before Using The Microscope All future users

More information

Digital Imaging - Photoshop

Digital Imaging - Photoshop Digital Imaging - Photoshop A digital image is a computer representation of a photograph. It is composed of a grid of tiny squares called pixels (picture elements). Each pixel has a position on the grid

More information

How is the Digital Image Generated? Image Acquisition Devices

How is the Digital Image Generated? Image Acquisition Devices In order for image analysis to be performed on a 2D gel, it must first be converted into digital data. Good image capture is critical to guarantee optimal performance of automated image analysis packages

More information

Training Guide for Leica SP8 Confocal/Multiphoton Microscope

Training Guide for Leica SP8 Confocal/Multiphoton Microscope Training Guide for Leica SP8 Confocal/Multiphoton Microscope LAS AF v3.3 Optical Imaging & Vital Microscopy Core Baylor College of Medicine (2017) Power ON Routine 1 2 Turn ON power switch for epifluorescence

More information

INTRODUCTION TO COMPUTER GRAPHICS

INTRODUCTION TO COMPUTER GRAPHICS INTRODUCTION TO COMPUTER GRAPHICS ITC 31012: GRAPHICAL DESIGN APPLICATIONS AJM HASMY hasmie@gmail.com WHAT CAN PS DO? - PHOTOSHOPPING CREATING IMAGE Custom icons, buttons, lines, balls or text art web

More information

Bit Depth. Introduction

Bit Depth. Introduction Colourgen Limited Tel: +44 (0)1628 588700 The AmBer Centre Sales: +44 (0)1628 588733 Oldfield Road, Maidenhead Support: +44 (0)1628 588755 Berkshire, SL6 1TH Accounts: +44 (0)1628 588766 United Kingdom

More information

Unit 4.4 Representing Images

Unit 4.4 Representing Images Unit 4.4 Representing Images Candidates should be able to: a) Explain the representation of an image as a series of pixels represented in binary b) Explain the need for metadata to be included in the file

More information

Sampling Rate = Resolution Quantization Level = Color Depth = Bit Depth = Number of Colors

Sampling Rate = Resolution Quantization Level = Color Depth = Bit Depth = Number of Colors ITEC2110 FALL 2011 TEST 2 REVIEW Chapters 2-3: Images I. Concepts Graphics A. Bitmaps and Vector Representations Logical vs. Physical Pixels - Images are modeled internally as an array of pixel values

More information

LSM 800 Confocal Microscope Standard Operation Protocol

LSM 800 Confocal Microscope Standard Operation Protocol LSM 800 Confocal Microscope Standard Operation Protocol Turning on the system 1. Switch on the Main switch (labeled 1 and 2 ) mounted on the wall. 2. Turn the Laser Key (labeled 3 ) 90 clockwise for power

More information

Graphics for Web. Desain Web Sistem Informasi PTIIK UB

Graphics for Web. Desain Web Sistem Informasi PTIIK UB Graphics for Web Desain Web Sistem Informasi PTIIK UB Pixels The computer stores and displays pixels, or picture elements. A pixel is the smallest addressable part of the computer screen. A pixel is stored

More information

How is Information Stored

How is Information Stored Binary CSCE 101 How is Information Stored Information is stored in the computer as binary numbers (0 s and 1 s). Even images are stored in this way, where a combination of 0 s and 1 s represent each color

More information

Last updated: May 2014 Y.DeGraaf

Last updated: May 2014 Y.DeGraaf FLINDERS MICROSCOPY BIOMEDICAL SERVICES AVAILABLE MICROSCOPES AND SPECIFICATIONS & INFORMATION REGARDING TRAINING FOR NEW USERS Last updated: May 2014 Y.DeGraaf If you have new staff or students (Honours/Masters

More information

Zeiss LSM 510 Confocor III Training Notes. Center for Cell Analysis & Modeling

Zeiss LSM 510 Confocor III Training Notes. Center for Cell Analysis & Modeling Zeiss LSM 510 Confocor III Training Notes Center for Cell Analysis & Modeling Confocor 3 Start Up Go to System Module Turn on Main Switch, System/ PC, and Components Switches Do you need the arc lamp?

More information

Computer Programming

Computer Programming Computer Programming Dr. Deepak B Phatak Dr. Supratik Chakraborty Department of Computer Science and Engineering Session: Digital Images and Histograms Dr. Deepak B. Phatak & Dr. Supratik Chakraborty,

More information

MIF ZEISS VIOLET CONFOCAL ZEN 2009 PROTOCOL

MIF ZEISS VIOLET CONFOCAL ZEN 2009 PROTOCOL MIF ZEISS VIOLET CONFOCAL ZEN 2009 PROTOCOL START-UP On the Switchbox, turn both black switches to the ON position. Wait for the microscope to boot up completely (watch the screen on the side of the microscope).

More information

Using the Nikon TE2000 Inverted Microscope

Using the Nikon TE2000 Inverted Microscope Wellcome Trust Centre for Human Genetics Molecular Cytogenetics and Microscopy Core Using the Nikon TE2000 Inverted Microscope Fluorescence image acquisition using Scanalytic s IPLab software and the B&W

More information

Camera Test Protocol. Introduction TABLE OF CONTENTS. Camera Test Protocol Technical Note Technical Note

Camera Test Protocol. Introduction TABLE OF CONTENTS. Camera Test Protocol Technical Note Technical Note Technical Note CMOS, EMCCD AND CCD CAMERAS FOR LIFE SCIENCES Camera Test Protocol Introduction The detector is one of the most important components of any microscope system. Accurate detector readings

More information

SPINNING DISK CSU-X1 USER MANUAL

SPINNING DISK CSU-X1 USER MANUAL SPINNING DISK CSU-X1 USER MANUAL Starting the temperature controller... 2 Starting the CO2 controller... 3 Start the spinning disk... 4 Sample observation with the oculars... 5 Spatial sampling, Pixel

More information

Confocal Laser Scanning Microscopy

Confocal Laser Scanning Microscopy Name of the Core Facility: Confocal Laser Scanning Microscopy CORE Forschungszentrum Immunologie Mainz Welcome to the CSLM Core Facility: The CLSM Core Facility enables working groups to incorporate high

More information

GUIDELINES FOR THE CREATION OF DIGITAL COLLECTIONS

GUIDELINES FOR THE CREATION OF DIGITAL COLLECTIONS GUIDELINES FOR THE CREATION OF DIGITAL COLLECTIONS Digitization Best Practices for Images This document sets forth guidelines for digitizing two-dimensional, non-textual materials for the CARLI Digital

More information

Making Professional Quality Scientific Figures: Part II Advanced Image Editing

Making Professional Quality Scientific Figures: Part II Advanced Image Editing Making Professional Quality Scientific Figures: Part II Advanced Image Editing RESOURCES: http://www.people.fas.harvard.edu/~draft/thesisworkshop/ PDF of this presentation PDF of instructions for image

More information

Nikon A1R. Multi-Photon & Laser Scanning Confocal Microscope. Kyle Marchuk Adam Fries Jordan Briscoe Kaitlin Corbin. April 2017.

Nikon A1R. Multi-Photon & Laser Scanning Confocal Microscope. Kyle Marchuk Adam Fries Jordan Briscoe Kaitlin Corbin. April 2017. Nikon A1R Multi-Photon & Laser Scanning Confocal Microscope Kyle Marchuk Adam Fries Jordan Briscoe Kaitlin Corbin April 2017 Contents 1 Introduction 2 2 Start-Up 2 3 Imaging 4 3.1 Sample Alignment...........................................

More information

Applying mathematics to digital image processing using a spreadsheet

Applying mathematics to digital image processing using a spreadsheet Jeff Waldock Applying mathematics to digital image processing using a spreadsheet Jeff Waldock Department of Engineering and Mathematics Sheffield Hallam University j.waldock@shu.ac.uk Introduction When

More information

Widefield 1. Switching on

Widefield 1. Switching on Widefield 1 Switching on 1. Ignite DG5 lamp - must be switched on first (if previous user has switched off, wait 30 min before igniting) 2. Wait 5s and then turn on the main DG5 controller switch. 3. DG5

More information

DIGITAL-MICROSCOPY CAMERA SOLUTIONS USB 3.0

DIGITAL-MICROSCOPY CAMERA SOLUTIONS USB 3.0 DIGITAL-MICROSCOPY CAMERA SOLUTIONS USB 3.0 PixeLINK for Microscopy Applications PixeLINK will work with you to choose and integrate the optimal USB 3.0 camera for your microscopy project. Ideal for use

More information

Images and Displays. Lecture Steve Marschner 1

Images and Displays. Lecture Steve Marschner 1 Images and Displays Lecture 2 2008 Steve Marschner 1 Introduction Computer graphics: The study of creating, manipulating, and using visual images in the computer. What is an image? A photographic print?

More information

User Guide to the IBIF Leica TCS SP8 MP Confocal Microscope

User Guide to the IBIF Leica TCS SP8 MP Confocal Microscope User Guide to the IBIF Leica TCS SP8 MP Confocal Microscope This version: 7.24.14. Introduction The IBIF confocal microscope is made available on a fee-for-use-hour basis to all users who have been trained.

More information

3. are adherent cells (ie. cells in suspension are too far away from the coverslip)

3. are adherent cells (ie. cells in suspension are too far away from the coverslip) Before you begin, make sure your sample... 1. is seeded on #1.5 coverglass (thickness = 0.17) 2. is an aqueous solution (ie. fixed samples mounted on a slide will not work - not enough difference in refractive

More information

Imaging Beyond the Basics: Optimizing Settings on the Leica SP8 Confocal

Imaging Beyond the Basics: Optimizing Settings on the Leica SP8 Confocal Imaging Beyond the Basics: Optimizing Settings on the Leica SP8 Confocal Todays Goal: Introduce some additional functionalities of the Leica SP8 confocal HyD vs. PMT detectors Dye Assistant Scanning By

More information

LECTURE 02 IMAGE AND GRAPHICS

LECTURE 02 IMAGE AND GRAPHICS MULTIMEDIA TECHNOLOGIES LECTURE 02 IMAGE AND GRAPHICS IMRAN IHSAN ASSISTANT PROFESSOR THE NATURE OF DIGITAL IMAGES An image is a spatial representation of an object, a two dimensional or three-dimensional

More information

Zeiss LSM 880 Protocol

Zeiss LSM 880 Protocol Zeiss LSM 880 Protocol 1) System Startup Please note put sign-up policy. You must inform the facility at least 24 hours beforehand if you can t come; otherwise, you will receive a charge for unused time.

More information

μscope Microscopy Software

μscope Microscopy Software μscope Microscopy Software Pixelink μscope Essentials (ES) Software is an easy-to-use robust image capture tool optimized for productivity. Pixelink μscope Standard (SE) Software had added features, making

More information

3D light microscopy techniques

3D light microscopy techniques 3D light microscopy techniques The image of a point is a 3D feature In-focus image Out-of-focus image The image of a point is not a point Point Spread Function (PSF) 1D imaging 1 1 2! NA = 0.5! NA 2D imaging

More information

ImageJ, A Useful Tool for Image Processing and Analysis Joel B. Sheffield

ImageJ, A Useful Tool for Image Processing and Analysis Joel B. Sheffield ImageJ, A Useful Tool for Image Processing and Analysis Joel B. Sheffield Temple University Dedicated to the memory of Dan H. Moore (1909-2008) Presented at the 2008 meeting of the Microscopy and Microanalytical

More information

Cell Biology and Bioimaging Core

Cell Biology and Bioimaging Core Cell Biology and Bioimaging Core Leica TCS SP5 Operating Instructions Starting up the instrument 1. First, log in the log book located on the confocal desk. Include your name, your lab s PI, an account

More information

Introduction to BioImage Analysis

Introduction to BioImage Analysis Introduction to BioImage Analysis Qi Gao CellNetworks Math-Clinic core facility 22-23.02.2018 MATH- CLINIC Math-Clinic core facility Data analysis services on bioimage analysis & bioinformatics: 1-to-1

More information

Life Science Instrumentation. New Generation. Light Sheet Fluorescence Microscope. Alph

Life Science Instrumentation. New Generation. Light Sheet Fluorescence Microscope. Alph Life Science Instrumentation Light Sheet Fluorescence Microscope New Generation Alph Modular Light Sheet Microscope Alpha 3 is a new generation of light sheet fluorescence microscope addressing the needs

More information

Travel to New Dimensions- LSM 880. The Resolution of a Microscope is limited. The Resolution of a Microscope is limited. Image. Image. Object.

Travel to New Dimensions- LSM 880. The Resolution of a Microscope is limited. The Resolution of a Microscope is limited. Image. Image. Object. Travel to New Dimensions- LSM 880 LSM 880: The Power of Sensitivity Our Latest Member of the LSM 880 with GaAsP Detectors Sensitivity, and Ease of Use Innovative High-End Laser Scanning Microscopes from

More information

Quick Start Guide. Leica SP5 X

Quick Start Guide. Leica SP5 X Quick Start Guide Leica SP5 X Please note: Some of the information in this guide was taken from Leica Microsystems Leica TCS SP5 LAS AF Guide for New Users. This work is licensed under the Creative Commons

More information