1 FDL A0(A0) Fire Damper FDL is equipped with electrical actuator, junction box and fusible link Halton FDL fire dampers are type-approved class A0(A0) fire dampers for use in offshore, marine and navy ventilation systems. The FDL can be installed in rectangular or circular ducts. The FDL dampers are used to prevent the spread of fire within the ventilation ductwork. All fire dampers have a fusible link and spring return actuator. When the blades are in the open position, the device does not cause significant pressure loss or flow disturbance. Fire dampers are set from outside and can be installed in any position. An open-closed indicator is visible on the outside of the damper. Fire dampers with non-standard dimensions can also be supplied on request. Type-approved by most recognized classification societies: class A0 without insulation, A-A0 when suitably insulated Available as ATEX approved. Shock-tested. Fixed frame and blades of painted, galvanized or stainless steel. aintenance-free stainless steel bearings and shafts. Blades without sealing Nominal fuse release temperature 0 ºC, ºC or 00 ºC. Other temperatures available. Can be installed in any position Automatic electrical, pneumatic or spring operation system available aximum duct pressure for damper construction 000 Pa and maximum air velocity m/s. In case of high duct pressure, contact Halton arine for finding the most suitable solution. PART ATERIAL FINISHING Frame Carbon steel Painted or galvanised Frame Stainless steel EN.0 (AISI0), EN.0 (AISIL), EN. (AISIL) - Blades Steel Galvanized Blades Stainless steel EN.0 (AISI0), EN.0 (AISIL), EN. (AISIL) - aintenance-free bearings Stainless steel EN.0 (AISIL) - Shafts Stainless steel EN.0 (AISIL) - FDL - A0(A0) Fire Damper
2 FDL DIENSIONS AND ATERIAL THICKNESS The Halton FDL fire dampers are manufactured according to international standards for both rectangular (width B mm and height H mm, mm division) and circular ducts (Ø00-0 mm). odular constructions are available for bigger sizes. Non-standard dimensions and flange drilling are available on request. Standard flange width mm. Flanges and drilling also available according to ISO standards. odular construction sizes up to 0x0 mm. Standard frame material thickness - mm. aterial thickness according to SOLAS available on request. Actuator effect on dimensions Frame thickness according to SOLAS DIENSIONS Electrical GGA.E 00 H<00 = 00 H>00 = H PNL PNR PNR Linear actuator /00 N rotating actuator AT00 rotating actuator AT00 R A 0 H<00 = 00 H>00 = H 0 H<00 = 00 H>00 = H 0 H<0 = 0 H>0 = H Spring Spring 0 H The above table contains only some examples of actuators and their effect on dimensions. DIENSIONS S L If B or H > 00, but < If B or H > 0, but < If B or H > 0 GENERAL FDL DRAWING FDL CIRCULAR CONNECTIONS Ø A 0 0 n*0 n*0 IN. 0 H+ H R IN. 0 n*0 B+ B+ n*0 GENERAL FDL DRAWING, TOP FDL CIRCULAR, WITH CONNECTION FLANGES, S=, S=, S= 0 S, ACCORDING TO SOLAS 0, BLADES IN POSITION ØD S, ACCORDING TO SOLAS ØD S, ACCORDING TO SOLAS, S=, S= 0, S=, S=, S= 0, S= FDL - A0(A0) Fire Damper
3 GENERAL FDL ODULE ASSEBLY FDL PRODUCT OPTIONS Halton FDL is available with following actuators: FDL-EL: Electrical spring return motor; standard actuators being V or 0 V or 0 V. The motor Size limitation: FDB: Nominal Width 00 x Nominal Height 0 or Nominal Width 0 x Nominal Height 0 FDL Nominal Width 0 x Nominal Height 0 contains built-in open-closed limit switches. Separate junction box included in the EL-model. A wide range of eex-proof actuators available, including a one second closing time function as an option. FDL-PNL: linear actuator, material stainless steel FDL-PNR: rotating actuator FDL-SP: anual spring-actuated damper with fusible link FDL Nominal height+ >0 nx 0 nx 0 >0 DOT: manual override function available for PNL, PNR and EL models. A wide range of accessories available. FDB Nominal height+ 0 (FDB) (FDL) >0 nx 0 nx 0 >0 0 (FDB) (FDL) Flat bar cross steel FDB Nominal with+ FDL Nominal with+ FDL ax.0 FDB ax.0 Flat bar steel Flat bars to be sealed with pyrocryl sealant OPERATION PRINCIPLE In the event of a temperature rise in ductwork: FDL-EL: fusible link releases and cuts off operating voltage to the spring return motor, allowing the spring to close the damper blades. The fire damper opens automatically when the fuse has been changed and the operating voltage to the motor is re-established. S in ax 0 FDL-PNL and FDL-PNR: fusible link releases and cuts off operating pressure to the spring return actuator, allowing springs to close the damper blades. The fire damper opens automatically when the fuse has been changed and the pneumatic air supply is re-established. FDL-SP: fusible link releases allowing the spring to close the damper blades. When the fuse has been changed, the fire damper must be reset into open position manually. C FDB ax.0 FDL ax L± DETAIL C SCALE : Flat bar steel both side of the damper V0Y0/Halton arine reserves the right to alter products without notice. WEIGHTS OF STANDARD HALTON ARINE FDL S (KG) without an actuator H/Height FDL - A0(A0) Fire Damper B / Width (mm) mm D ØD Weight 00 () () () 0 (0) () () () () () 0 (0) () () () mm kg 00 () () () () () () () 0 () () () () () () 00 () 00 () () () () () () (0) () () () () () () () 00 () () () () 0 () () () () () 0 () () () () 0 () 00 () () () () () (0) () 0 () () () (0) () () 00 () 00 () () 0 () () (0) () 0 () () () () 0 () () () 0 () 00 () () () () () () () (0) 0 () () (0) () () 0 (0) 00 0 () () () () () () (0) 0 () () () () () () 00 () 00 () () () () () (0) () () () 0 () (0) () () 00 () 000 () () () () (0) 0 () () () 0 () (0) () 0 () () 0 () 00 () 0 () () () 0 () () () () () () () () () 00 () 00 () () () () () () 0 () (0) () () () () () 000 () Examples of actuator weights: FDL-EL GGA.E, kg, GNA.E, kg, BF0 +, kg, BLF0 +, kg, Exax /Redmax +, kg, CSQP + kg, 0 () FDL-PNL Roder + kg, FDL-PNR AT00 +, kg, AT00 as AISI +, kg, AT00 +, kg, AT00 as AISI +, kg, FDL-SP + kg. Control enclosure + kg. (Frame thickness according to SOLAS)
4 FDL-EL WIRING DIAGRA with Belimo actuator FDL-EL WIRING DIAGRA with Belimo-T actuator, 0, 0 VAC VDC, 0 VAC... VDC N/- L/+ 0 BN BU (BN) (BU) S S S S S S 0 N/- L/+ 0 S S S S S S 0 x 0, mm² x 0, mm² x 0, mm² x 0, mm² SIHF x 0, mm² S S S S S S 0 WHEN IS NOT ENERGIZED CONTACTS S-S, S-S ARE BELIO BF BF0 BF0 BLF BLF0 BLF0 IP INTERNAL THERAL SWITCH C BAE-S S S S S S S 0 WHEN IS NOT ENERGIZED CONTACTS S-S, S-S ARE BELIO BF-T BF0-T IP FDL-EL WIRING DIAGRA with Exax or Redax actuator -0V AC/DC PE FDL-EL WIRING DIAGRA with Elodrive actuator V AC/DC 0/0 V AC PE PE -EARTHING RAIL PE L/+ N/- 0 0 BK GY BN L/+ N/- 0 0 x 0, mm² x 0, mm² x 0, mm² BK GY BN PE HEATER WHEN IS NOT ENERGIZED CONTACTS S-S, S-S ARE Exax-.0-SF Redax-.0-SF Exax--SF Redax--SF IP SIHF x 0, mm² x 0, mm² N T - L ~ + ELODRIVE CSQP-0AE CSQP-0AE CSQP-0AE CSQP-0AE CSQP-AE CSQP-AE IP FDL - A0(A0) Fire Damper
5 SIHF x 0, mm² FDL-EL WIRING DIAGRA with Siemens actuator, 0, 0 VAC... VDC 0 0 BN BU BN BU S S S S S S () () x 0, mm² x 0, mm² () () S S S S S S 0 WHEN IS NOT ENERGIZED CONTACTS S-S, S-S ARE SIEENS GGA..E/HA GGA..E/HA GGA..E/HA GNA..E/HA GNA..E/HA IP FDL-PNR/PNL PNEUATIC DIAGRA LIIT SWITCHES SPRING RETURN SPEED CONTROLLER QUICK EXHAUST VALVES PIPELINES:POLYAIDE VALVE PORT/ WAY ANUAL VALVE PORT/ WAY SOLENOID VALVE PORT/ WAY PNEU. INLET ( - BAR) PRESSURE REGULATOR FOR A PLASTIC TUBE Ø 0 /0 V. SPRING RETURN VALVE. QUICK EXHAUST VALVE. SILENCER. VALVE. SOLENOID VALVE. ALE CONNECTOR. DOUBLE NIPPLE. PLASTIC TUBE. STAINLESS STEEL. / SWITCHES 0. ANUAL VALVE. PRESSURE REGULATOR. SPEED CONTROLLER V0Y0/Halton arine reserves the right to alter products without notice. FDL-EL WIRING DIAGRA with Siemens-HA actuator, 0 VAC... VDC S S S S S S 0 0 x 0, mm² x 0, mm² TEPERATURE ONITORING UNIT C () () S S S S S S 0 WHEN IS NOT ENERGIZED CONTACTS S-S, S-S ARE SIEENS GGA..E/HA GGA..E/HA SIEENS-HA FDL - A0(A0) Fire Damper
This FDB2 has been customized with the following options: NORSOK flanges, control enclosure, ATEX certified components and steel tubing
FDB A0(A0) Fire And Gas Damper This FDB has been customized with the following options: NORSOK flanges, control enclosure, ATEX certified components and steel tubing Halton FDB fire dampers are type-approved
More informationCONTROL Room. Room product for Swegon s WISE system for demand-controlled ventilation. Quick facts Room control against temperature, CO 2
Room product for Swegon s WISE system for demand-controlled ventilation Quick facts Room control against temperature, CO 2, content, etc. Static pressure and flow measurement Position-independent Shut-off-capable
More informationVolumetric flow controller
Volumetric flow controller Model VRA Leakage air flow with control damper closed according to DIN EN 1751, up to class 4 Ferdinand Schad KG Steigstraße 25-27 D-78600 Kolbingen Telephone +49 (0) 74 63-980
More informationVolumetric flow controller
Volumetric flow controller VRAR Leakage air flow with control damper closed according to DIN EN 1751, up to class 3 Ferdinand Schad KG Steigstraße 25-27 D-78600 Kolbingen Telephone +49 (0) 74-980 - 0 Fax
More informationAir damper actuators Rotary version with spring return, AC 24 V / DC V / AC 230 V
4 614 OpenAir T Air damper actuators Rotary version with spring return, / DC 24 48 V / AC 230 V GA..1 Electronic motor driven actuators for two-position, three-position, and modulating control, nominal
More informationAC centrifugal fan. R2E180-AS backward curved, single inlet. Nominal data
Nominal data Type Motor ME68-BF Phase ~ ~ Nominal voltage VAC Frequency Hz 5 6 Type of data definition fa fa Valid for approval / standard CE CE Speed min - Power input W 8 Current draw A.6.5 Motor capacitor
More informationThe ZSH stepper motor convinces with its robust housing with high-strength cable gland. The motor is waterproof up to 10 m with the IP68 option.
/ZSH HRSH ZSH Stepper otor Robust. Powerful. Reliable. Phytron s HRSHEnvironment motors are particularly suitable for challenging applications in mechanical engineering and industry. Challenging conditions
More informationMADEL. SCC control dampers for circular duct
SCC control dampers for circular duct ADE The SCC series dampers are designed to be used for altering the flow volume rate and pressure in airconditioning, ventilation and heating systems. Airtight damper
More informationCONTROL UNITS. VEHICLE EXHAUST GASES Pure advantages VEHICLE EXHAUST GASES
CONTROL UNITS VEHICLE EXHAUST GASES Fumex s control s offers a good working environment, adapted to all types of facilities. The right choice of control s is energy-saving and provides the lowest possible
More informationRotary actuators for ball valves
4 658 Rotary actuators for ball valves for ball valves VAI61.. / VBI61.. and VAI60.. / VBI60.. / DC 24 48 V / AC 230 V Electromotive rotary actuators with spring return for emergency position For 2-position,
More informationPD30ETB20xxIS. Photoelectrics, Background Suppression reflective with IR light. Main features. Description
Photoelectrics, Background Suppression reflective with IR light Main features Description The PD30ET... stainless steel sensors are built with high-quality materials and designed for harsh environments.
More informationDuctwork Controls and Instrumentation Outlets (HVAC) HVAC Control System.
SECTION 15910 DUCT ACCESSORIES PART 1 GENERAL 1.01 SUMMARY A. Related Sections: 1. 15890 - Ductwork. 2. 15900 - Controls and Instrumentation. 3. 15940 - Outlets (HVAC). 4. 15970 - HVAC Control System.
More information4.5. Module System MODULE SYSTEM FOR ELECTRIC ACTUATORS TECHNICAL DATA GENERAL APPLICATIONS. Current feedback: Protection class: Limit switches:
ODULE SYSTE FOR ELECTRIC ACTUATORS TECHNICAL DATA Electric quarter turn actuators series E65 to E210 with module system are designed to automate valves. Nominal torque: Protection class: Duty Cycle: es:
More informationABSOLUTE ROTARY ENCODER MULTI-TURN BIT PARALLEL
Main Features - Compact and heavy-duty industrial model - Interface: Bit-parallel, push pull Œ Short circuit proof - Housing: 58 mm - Shaft: 6 or 10 mm - Resolution: Max. 25 Bit =,554,42 steps over 4,096
More informationPRESTON HEALTH SERVICES ARCHITECT S NO. 2700
SECTION 23 3113 - LOW PRESSURE DUCTWORK PART 1 - GENERAL 1.1 SCOPE OF WORK: A. The work required under this section includes all work necessary for a complete installation of ductwork and accessories.
More informationInstallation Instructions Student 101 Fume Cupboard
Installation Instructions Student 101 Fume Cupboard Refer drawing on next page 0. If your fume cupboard is supplied with a flatpack bench frame, see step1. If your fume cupboard will be mounted on an existing
More informationExplosion proof rotary actuator - On/Off or programmable regulating actuator
Explosion proof rotary actuator - On/Off or programmable regulating actuator Direct mounting for quarter-turn valves Manual override standard Corrosion resistant Adjustable limit switches Type 3004 can
More informationGlass-fibre-reinforced polycarbonate. Dead zone Adaptive or fixed from % 20 ms. 60 ms. 60 ms. Approx. 1.3 kg. Approx. 0.9 kg. Approx. 5.
General data Mounting On linear actuators On quarter turn actuators ARCA-integrated or to VDI/VDE 3847-1 or IEC 534-6 (NAMUR) Range of stroke: 3... 130 mm Integrated to VDI/VDE 3847-2 or VDI/VDE 3845 Angle
More informationGlass-fibre-reinforced polycarbonate. Dead zone Adaptive or fixed from % 1.5 s adjustable. 20 ms. 60 ms. 60 ms. Approx. 1.
General data Mounting On linear actuators On quarter turn actuators ARCA-integrated or to VDI/VDE 3847-1 or IEC 534-6 (NAMUR) Range of stroke: 3... 130 mm Integrated to VDI/VDE 3847-2 or VDI/VDE 3845 Angle
More informationFastening material. Lindab 1. General information and theory 2. Safe 3. Silencers 4. Dampers & Measure units 5. Fire dampers & Smoke evacuation
Fastening material Lindab General information and theory Safe Silencers Dampers & Measure units Fire dampers & Smoke evacuation Air valves Roof hoods Other circular products Transfer 0 Rectangular Flexible
More informationNK / NL series. Rectangular VAV and CAV air volume control terminals
NK / NL series Table of contents Description Page Type designation 1 Technical data - General 2 - Specification 3 - Installation instruction 3 Model overview / dimensions 4-5 Sound data NKOAOOB / NLOAOOB
More informationInstallation and Operating Instructions Differential pressure transmitter for potentially explosive areas. MG-1000-EEx USAGE STRUCTURE AND DESIGN
Installation and Operating Instructions Differential pressure transmitter for potentially explosive areas Mimablad: 176GB/1999-10-25 Ersätter: MG-1000-EEx USAGE MG-1000-EEx is suitable for use in measurement
More informationCONNOLS-AIR. AIR TERMINAL UNITS Engineered for Versatile Application and Energy Conservation
CONNOLS-AIR AIR TERMINAL UNITS Engineered for Versatile Application and Energy Conservation Marina Bay Business District is considered the trendiest and most technologically advance area for business in
More informationRotary Measurement Technology Incremental Encoders
-20 to 60 C Temperature Shock/vibration resistant Short-circuit protection Reverse polarity protection High rotational speed Rugged Balanced, stainless-steel clamping rings, special bearing-shaft connection
More informationIncremental encoders Blind hollow shaft or cone shaft pulses per revolution
Features TTL output driver for cable length up to 550 m Very high resistance to shock and vibrations Hybrid bearing for extended service life Shaft insulation up to.8 kv Large terminal box, turn by 80
More informationPressure transmitters for high temperature marine applications Type MBS 3300 and MBS 3350
Pressure transmitters for high temperature marine applications Type MBS 3300 and MBS 3350 Technical brochure Features Designed for use in severe maritime environments For medium and ambient temperatures
More informationBONOMI NORTH AMERICA SERIES 500N - 500S
BOI RTH AERICA SERIES 500N - 500S NYON COATED DISC CF SS DISC anually operated butterfly valves. Epoxy coated cast iron wafer body. Full port sizes / to. EPD resilient seat -0 F to 50 F. API609 face to
More informationCONSTRUCTION MATERIALS SERVICE CONDITIONS. Alternative alloy materials, like AISI 904L or DUPLEX stainless steel, are available if required.
SLIDE GATE The model is a rectangular penstock suitable for wall and thimble mounting, with a resilient sealing member applied to all 4 sides. There are two different designs, which are size dependent,
More informationLOW PRESSURE STEEL DUCTWORK Mechanical Systems Insulation Outlets (HVAC) Testing and Balancing.
SECTION 15841 LOW PRESSURE STEEL DUCTWORK PART 1 GENERAL 1.01 SUMMARY A. Related Sections: 1. 15180 - Mechanical Systems Insulation. 2. 15940 - Outlets (HVAC). 3. 15991 - Testing and Balancing. 1.02 SUBMITTALS
More informationEC centrifugal fan - RadiCal
ebm-papst Mulfingen GmbH & Co. KG Bachmühle D-74673 Mulfingen Phone +49 7938 81- Fax +49 7938 81-11 info1@de.ebmpapst.com www.ebmpapst.com Limited partnership Headquarters Mulfingen County court Stuttgart
More informationCompact Electric Actuator. JFEW Series
Compact Electric Actuator JFEW Series JFEW-000 - Suitable for small ball valve automation. - Very high efficiency & cyclic life. - Free voltage (85~65 VAC,Phase) and optional VAC/DC - Very compact and
More informationCOLIBRI Ceiling. Square ceiling diffuser with discs for supply air QUICK FACTS
Square ceiling diffuser with discs for supply air QUICK FACTS Adjustable discs flexible spread pattern Can be used for vertical air diffusion Swirl function Also available in the Extract air version Designed
More informationTangential Fans - Basic principles. Expertise, performance, innovation
Tangential Fans - Basic principles Expertise, performance, innovation Fans 1 Stove jacket cooling, storage heaters, wood-burning stoves, underfloor convectors, tanning beds, air conditioners and heaters
More informationREACTa. Installation Commissioning Maintenance Installation circular version Legend to figures 3-5: Min. 500 mm. Min.
a Installation Commissioning Maintenance 20180125 Installation ir flow measuring of requires a straight section of duct before the unit (in air flow direction), according to installation figures. Modbus
More informationOPTIFLUX 5000 Technical Datasheet
OPTIFLUX 5000 Technical Datasheet Electromagnetic flowmeter in flanged version Exceptional long-term stability and accuracy For highly aggressive and abrasive fluids Fully vacuum-resistant with high-tech
More informationValve Series V2001 Globe Valve Type 3321 with Pneumatic or Electric Actuator
Valve Series V2001 Globe Valve Type 3321 with Pneumatic or Electric Actuator ANSI version Application Control valves designed for mechanical and plant engineering. Suitable for liquids, gases and steam
More informationKitchen exhaust fan GLEB
Kitchen exhaust fan GLEB Contents Kitchen exhaust fan - GLEB...3 Performance Data...4 Dimensions...5 Wiring diagram...6 General description...7 Applications...7 Demand control ventilation...7 Quiet operation...7
More informationEconomic Style Electric Actuator. ITQ Series
Economic Style Electric Actuator ITQ Series BS EN ISO 900:000 ITQ 000 - Suitable for small ball valve automation. - Very high efficiency & cyclic life. - Free voltage (85~65 VAC,Phase) and optional 4VAC/DC
More informationCOLIBRITM. Ceiling. Square ceiling diffuser with discs for supply air. Quick guide
COLIBRITM Ceiling Square ceiling diffuser with discs for supply air Quick facts Adjustable discs flexible spread pattern Can be used for vertical air diffusion Swirl function Also available in the exhaust
More informationRotary actuators for ball valves
4 658 Rotary actuators for ball valves for ball valves VA..61.. / VB..61.. and VA..60.. / VB..60.. / DC 24 48 V / AC 230 V GA..9E Electromotive rotary actuators with spring return for emergency position
More informationGLB...9. Ball Valve actuators. Building Technologies HVAC Products. for valves VAI61... AC 24 V / AC 230 V
4 657 Ball Valve actuators GLB...9 for valves VAI61... / Electronic motor driven actuators for three-position and modulating control, pre-wired with 0.9 m long connection cables. Remarks This data sheet
More informationRECTANGULAR CAV AND VAV AIR VOLUME CONTROL TERMINALS NK / NL SERIES
RECTANGULAR CAV AND VAV AIR VOLUME CONTROL TERMINALS NK / NL SERIES Table of contents Description Page Type designation 1 Technical data - General 2 - Specification 3 - Installation instruction 3 Model
More informationEC centrifugal fan - RadiCal
RG-RD- ebm-papst Mulfingen GmbH & Co. KG Bachmühle D-7467 Mulfingen Phone +49 798 8- Fax +49 798 8- info@de.ebmpapst.com www.ebmpapst.com Limited partnership Headquarters Mulfingen County court Stuttgart
More informationALPHA DIN Wall-Mounted. Distribution Boards
Siemens AG 008 ALPHA 160 - DIN Wall-Mounted Distribution Boards / Introduction Distribution Boards with Built-In Distribution Board Panels /4 8GK1 surface and flush-mounting with quick-assembly kits Unequipped
More informationAC/DC 24 V, 50/60 Hz. Functional data Variable Settings. DC V, max. 0.5 ma. End point DC V... 4 ma ma Non-variable
echnical data sheet S--MF- Multifunctional rotary actuator for butterfly valves orque 00 Nm Nominal volta e V Control: ontrol configurable confi urable Position feedback: configurable Auxiliary u iliary
More informationRoHS. High shaft load capacity. Shock / vibration resistant
Due to their sturdy bearing construction in Safety Lock Design, the Sendix 5000 and 5020 offer high resistance against vibration and installation errors. The rugged housing, high protection level of up
More informationEC centrifugal fan. forward curved, dual inlet with housing (flange)
ebm-papst Mulfingen GmbH & Co. KG Bachmühle 2 D-74673 Mulfingen Phone +49 7938 81- Fax +49 7938 81-11 info1@de.ebmpapst.com www.ebmpapst.com Limited partnership Headquarters Mulfingen County court Stuttgart
More informationCombiTemp TCR6 Standard RTD temperature sensor
Main features Sensor and connection in stainless steel, ISI 6 DIN form B housing Robust design pplications Industrial applications with industrial process connection Pipe systems Heating systems Water
More informationElectric Actuator. of innovated design. Introducing KIMAX CONTROLS INC. > Patented switch of manual & Motor operation. Clutchless manualoverride.
CONTROLS INC. Introducing KIMAX CONTROLS INC. Kimax Taiwan : 5F-10,No.3, Lane 2, First Industrial Rd., Taichung Taiwan, 40767 Tel:886-4-23507533 Fax:886-4-23507531 E-mail:eric-shia@kimax.com.tw Kimax China
More informationTarget disk flowmeters Series DP Metallic flowmeter for liquids and gases
Target disk flowmeters Series DP Metallic flowmeter for liquids and gases Metallic, simple and robust construction Available for all flow directions Suitable for extreme pressure and temperature conditions
More informationRotary Measuring Technology
Our ATEX encoders now also carry approval for Dust Flameproof-enclosure type of construction with approval for Zone 1 and 21 ExII2GEExdIICT6 and ExII2DIP6xT85 C Shaft ø 12 mm One type for every situation:
More informationEC centrifugal fan - RadiCal
ebm-papst Mulfingen GmbH & Co. KG Bachmühle D-74673 Mulfingen Phone +49 7938 8- Fax +49 7938 8- info@de.ebmpapst.com www.ebmpapst.com Limited partnership Headquarters Mulfingen County court Stuttgart HRA
More informationValves, Actuators, Accessories. N Series Solenoid Valve
Valves, Actuators, Accessories N eries olenoid Valve Technical Data Function Manual override Design Mounting Mounting position Material specifications Media Fluid temperature Electrical parts Voltage Voltage
More informationHeavy Duty Push-pull / RS422 / speed switch. RoHS 2/22. Magnetic field proof. XXXX e
Sendix H00 (shaft) The Sendix encoder H00 is an extremely rugged available in 3 versions: encoder with or without speed switch and double encoder. Thanks to the special HD-Safety-Lock construction it is
More informationEC centrifugal fan. R3G175-AF25-02 backward curved, single inlet. Nominal data
ebm-papst Mulfingen GmbH & Co. KG Bachmühle 2 D-74673 Mulfingen Phone +49 7938 81-0 Fax +49 7938 81-110 info1@de.ebmpapst.com www.ebmpapst.com Nominal data Type Motor M3G055-CF Phase 1~ Nominal voltage
More informationSRS SEALED ROTARY SENSORS
SRS SEALED ROTARY SENSORS Innovation In Motion INNOVATION IN MOTION Penny+Giles SRS280 sealed rotary sensors and SRS880 submersible rotary sensors have been specially developed to provide maximum performance
More information2/2 Introduction. Unequipped Distribution Boards 2/5 8GK1 surface and flush-mounting distribution boards
Siemens AG 010 ALPHA 160 - DIN Wall-Mounted Distribution Boards / Introduction Distribution Boards with Built-In Distribution Board Panels /4 8GK1 surface and flush-mounting with quickassembly kits Unequipped
More informationCondumax W CLS15 and CLS15D
Technical Information Condumax W CLS15 and CLS15D Conductivity sensors, analog or digital with Memosens technology, Cell constant k = 0.01 cm -1 or k = 0.1 cm -1 Application Measurement in pure and ultrapure
More informationABSOLUTE ROTARY ENCODER SSI
Main Features - Compact and heavy-duty industrial model - Interface: Synchronous-serial (RS422/485) - Housing: 58 mm - Shaft: 6 or 10 mm - Resolution: Max. 25 Bit =,554,42 steps over 4,096 revolutions
More informationRotary Position Technology Incremental Encoders
-40 to 80 C Temperature Shock/vibration resistant Short-circuit protected Reverse polarity protection High rotational speed Rugged Balanced, stainless-steel clamping rings, special bearing-shaft connection
More informationPower consumption In operation At rest For wire sizing. 150 s / C Sound power level Motor. Emergency setting function 61 db (A)
echnical Data sheets GRK4A-SR-5 Modulating SuperCap rotary actuator with emergency setting function and extended functionalities for butterfly valves and ball valves with mounting flange ISO 511-F05 orque
More informationEC centrifugal fan - RadiCal
ebm-papst Mulfingen GmbH & Co. KG Bachmühle D-7467 Mulfingen Phone +49 798 8- Fax +49 798 8- info@de.ebmpapst.com www.ebmpapst.com Limited partnership Headquarters Mulfingen County court Stuttgart HRA
More informationAMRI is ISO 9001 approved. Direct 1/4 turn electric actuators ACTELEC 3, 6, 12, 25, 50, 100 and 150 Output torques up to 1500 Nm
Technical leaflet 8521.11--10 ACTELEC 3 to 1600 Direct 1/4 turn ACTELEC 3, 6, 12, 25, 50, 100 and 150 Output torques up to 1500 Nm Direct 1/4 turn actuator Actuator with multi -turn servomotor associated
More informationEN 1092 PN 10 EN 1092 PN 16 JIS B K ANSI B16.5 Class 150 ANSI B16.47 Class 150 BS 10 Table D
HG EN 1092 PN 10 EN 1092 PN 16 JIS 2238 10K ANSI 16.5 Class 150 ANSI 16.47 Class 150 S 10 Table D Stafsjö s knife gate valve HG is a bi-directional valve, particularly well suited for severe operating
More informationEC centrifugal fan. forward curved, dual inlet with housing (flange)
D3G133-BF3-6 ebm-papst Mulfingen GmbH & Co. KG Bachmühle 2 D-74673 Mulfingen Phone +49 7938 81- Fax +49 7938 81-11 info1@de.ebmpapst.com www.ebmpapst.com Limited partnership Headquarters Mulfingen County
More information5/2 Introduction. Unequipped Distribution Boards 5/4 Modular distribution boards 5/5 Add-on parts
ALPHA AS Modular Distribution Boards /2 Introduction Unequipped Distribution Boards /4 Modular distribution boards / Add-on parts Assembly Kits for Unequipped Distribution Boards /6 8GK4 assembly kits
More informationAbsolute Encoders Multiturn
Absolute Encoders Multiturn Functional Safety, optical The absolute multiturn encoders Sendix 5863 SIL and 5883 SIL are perfectly suited for use in safety-related applications up to SIL3 according to DIN
More informationKEITH PANEL SYSTEMS FUNDERMAX- MAX EXTERIOR EXPOSED FASTENER PRESSURE EQUALIZED WALL SYSTEM
S Y S T E M D E T A I L S FUNDERMAX- MAX EXTERIOR EXPOSED FASTENER PRESSURE EQUALIZED WALL SYSTEM PAGE TITLE PAGE Table of Contents Fundermax Max Exterior Product Information Design and Installation Information
More informationseries SMLD Smoke Evacuation Damper
series SMLD Smoke Evacuation Damper www.koolair.com Series SMLD 1 CONTENTS Description 2 Dimensions 4 Installation 6 Electrical connections 7 Technical data 9 Coding 11 2 Series SMLD Description Multi-blade
More informationBase Mounted Plug-in Unit
For details about certified products conforming to international standards, visit us at www.smcworld.com. 000 Plug-in Unit SI unit COM N V V C C C6 M CM 6 B B B6 B M 000 Manifold model Plug-in unit Stations
More informationDifferential pressure sensors
1 912 1912P02 QBM64/ 1912P01 QBM63/ Differential pressure sensors for air and non-aggressive gases, with a diaphragm sensing element QBM63/ QBM64/ With choice of pressure-linear or extracting-the-root
More informationSLIDE GATE. The MU series is used mainly in water treatment, irrigation, hydraulic works and hydro-electric power plants.
SLIDE GATE The model is a rectangular penstock suitable for wall and thimble mounting, with a resilient sealing member applied to all 4 sides. There are two different designs, which are size dependent,
More informationVAV Rectangular Terminal Units
RSVQ VAV Rectangular Terminal Units RSVQ Variable Air Volume (VAV) HVAC systems are the best solution to guarantee high levels of comfort and energy effi ciency in civil and industrial applications VAV
More informationPD30CNB25xxPS. Photoelectrics, Background suppression reflective - PointSpot. Main features. Main functions. Description
Photoelectrics, Background suppression reflective - PointSpot Main features Miniature sensor range The visible red PointSpot light makes alignment very easy Range: 250 mm Sensitivity adjustment by potentiometer
More informationOPTIFLUX 5000 Technical Datasheet
OPTIFLUX 5000 Technical Datasheet Electromagnetic flowmeter in flanged version Exceptional long-term stability and accuracy For highly aggressive and abrasive fluids Fully vacuum-resistant with high-tech
More informationFlow Measurement SITRANS F M
Overview Mode of operation The flow measuring principle is based on Faraday s law of electromagnetic induction according to which the sensor converts the flow into an electrical voltage proportional to
More informationTarget disk flowmeter for liquids and gases
Target disk flowmeter for liquids and gases Metallic, simple and robust construction Available for all flow directions Suitable for extreme pressure and temperature conditions Low pressure drop Straight
More informationCover Page - Electric Actuators & Accessories. Standard & Optional Features. OM Actuator Standard Features. OM Actuator Optional Features
SECTION 5 INDEX DESCRIPTION Cover Page - Electric Actuators & Accessories Standard & Optional Features OM Actuator Standard Features OM Actuator Optional Features V / Actuator Selection Chart OM1 Actuator
More informationIncremental encoders Redundant sensing, isolated blind hollow shaft ø mm, cone shaft ø17 mm pulses per revolution
Features Robust, compact housing Two bearings with large distance, one at each end High shaft load up to 450 N Shock resistant up to 250 g Shaft insulation up to 2.8 kv Highest operating speed 10000 rpm
More informationDCS-62 Series Spring Return Electronic Actuator Product Bulletin
Delta Control Products, Inc. 0 West Rose Garden Lane Phoenix, Z 807 6-780-08 DCS-6 Series Spring Return Electronic ctuator Product ulletin Description The Delta DCS-6 direct-coupled spring return electronic
More informationEC centrifugal fan - RadiCal
RG5-RE7- ebm-papst Mulfingen GmbH & Co. KG Bachmühle D-746 Mulfingen Phone +49 798 8- Fax +49 798 8- info@de.ebmpapst.com www.ebmpapst.com Limited partnership Headquarters Mulfingen County court Stuttgart
More informationNOVOTURN Multiturn Sensor non-contacting. Series RSM-2800
NOVOTURN Multiturn Sensor non-contacting Series RSM-2800 Special features Non-contacting, magnetic Long life Electrical range 720 up to 5760 in 360 -steps available (2 to 16 turns) True-Power-On System:
More informationLexium integrated drives
Description ILp for CANopen, PROFIBUS DP, RS ILA with AC synchronous servo motor Description ILA comprise control electronics with a fieldbus interface for CANopen DS, PROFIBUS DP or RS and an AC synchronous
More informationDigital flow transmitter for continuous flow measurement
Digital flow transmitter for continuous flow measurement Compact or remote version for DN 06 to 400, PN10 Shows both flow rate and volume (with two totalizers) Automatic-calibration: TEACH-IN Simulation:
More informationAE SERIES ACTUATORS 2016 EDITION. The Best Way To Automate Your Process. Modulating Capable. Extended Duty Cycle Models Fast Acting Models
The Best Way To Automate Your Process St a n d a r d Vo l t age s 110/240/380/480V 24/24VDC Modulating Capable Extended Duty Cycle Models Fast Acting Models AE SERIES ACTUATORS 2016 EDITION Max-Air Technology,
More informationElectronically controlled proportional pressure regulating valves
Overview Description airfit control Electronically valve G1/4, G3/8, Type SRE-.. airfit control Electronically valve G3/8, G1/2, Type CRE-.. airfit control Electronically valve G3/4, G1, Type A25RE-..
More information847H. Description. Features. Specifications
847H Bulletin 847H High Performance Industrial Incremental Encoders provide code disk resolutions of up to 65536 pulses per revolution at a signal frequency response of 820 khz. The 847H can provide 65536
More informationLocal control stations for Zone 1 and Zone 21. Features. Description
Local control stations for Zone and Zone Local control stations for Zone and Zone Features The right size/material enclosure Optimum functionality thanks to the great variety of components Customised planning
More informationEC centrifugal fan - RadiCal
ebm-papst Mulfingen GmbH & Co. KG Bachmühle D-74673 Mulfingen Phone +49 7938 8- Fax +49 7938 8- info@de.ebmpapst.com www.ebmpapst.com Limited partnership Headquarters Mulfingen Amtsgericht (court of registration)
More informationSITRANS F flowmeters SITRANS F M. Flow sensor MAG /48 Siemens FI Overview
Siemens AG 2009 Overview Integration The complete flowmeter consists of a flow sensor and an associated transmitter MAG 5000, 6000 or 6000 I. The flexible communication concept USM II simplifies integration
More informationExtension for ground plate Z-SMA. Shaft extension AV8-25. Reversible spindle clamp K-SA. Damper crank arm KH8. Extension from SM.. or AM.. to SM..A..
echnical data sheet Mechanical accessories for SM..A.. Extension for ground plate Z-SMA Extension from SM.. or AM.. to SM..A.. Galvanized steel Shaft extension AV8-25 Length approx. 250 mm For damper spindles
More information2 Safety Barriers. Single-Channel Safety Barriers with Electronic Current Limitation Series 9004
2 Safety Barriers Single-Channel Safety Barriers with Electronic Current Limitation Series 9004 Broad product range for all standard applications in the world of automation Flexible and space saving Time
More informationPressure Transmitter SIL
Pressure Transmitter SI Characteristics - TRANSDUCER - Pressure: Range: Output: Accuracy: Temperature of medium: Material enclosure: Pressure connection: Electrical connection: Protection: relative / absolute
More informationEC centrifugal fan. forward curved, dual inlet with housing (large flange)
D3G146-HQ13-4 ebm-papst Mulfingen GmbH & Co. KG Bachmühle D-74673 Mulfingen Phone +49 7938 81- Fax +49 7938 81-11 info1@de.ebmpapst.com www.ebmpapst.com Limited partnership Headquarters Mulfingen County
More informationCompact Motorized Actuator
Compact otorized Actuator Using the superior characteristics of the best selling ELY butterfly valve actuator, we developed an improved successor, the. With a replaceable control circuit board, tough metal
More informationILA. Round ducts and fittings. Flexible duct connector for circular ducts without flanges. Dimensions. Description. ALNOR ventilation systems.
Flexible duct connector for circular ducts without flanges IA IA Flexible duct connector with male ends for joining two spiral or plain round ducts. Most commonly used for reducing vibration caused by
More informationTS-9100 Electronic Sensors and Transducers. Features and Benefits. G Wide range of enclosures and signal outputs
European Electronic Controls Catalogue Catalogue Section A Product Bulletin TS-9100 Issue Date 09 2000 TS-9100 Electronic Sensors and Transducers I ntroduction The TS-9100 series of electronic temperature
More informationAC centrifugal fan. Limited partnership Headquarters Mulfingen County court Stuttgart HRA
GE-AR77- ebm-papst Mulfingen GmbH & Co. KG Bachmühle D-767 Mulfingen Phone +9 798 8- Fax +9 798 8- info@de.ebmpapst.com www.ebmpapst.com Limited partnership Headquarters Mulfingen County court Stuttgart
More informationAbsolute Encoders - Singleturn
The Sendix 5853 and Sendix 5873 singleturn encoders with SSI or BiSS interface and optical sensor technology can achieve a resolution of max. 7 bits. These encoders are also available with an optional
More informationFlow Measurement SITRANS F M. Flow sensor MAG /49. Overview
Siemens AG 2010 Flow Measurement Overview Mode of operation The flow measuring principle is based on Faraday s law of electromagnetic induction according to which the sensor converts the flow into an electrical
More information