Valves, Actuators, Accessories. N Series Solenoid Valve

Size: px
Start display at page:

Download "Valves, Actuators, Accessories. N Series Solenoid Valve"

Transcription

1 Valves, Actuators, Accessories N eries olenoid Valve

2 Technical Data Function Manual override Design Mounting Mounting position Material specifications Media Fluid temperature Electrical parts Voltage Voltage tolerance Applications 3 or 5port directional valves for the control of single or double acting pneumatic actuators The interface design corresponds to the NAMUR standard and the VDI/VDE 3845 recommendations of the actuator industry permitting a compact design of the actuator/valve unit. 3/2, 5/2 and 5/3 solenoid and air operated valves. Locking manual override standard on all solenoid operated versions. Pilot operated spool valve with combined pneumatic and spring return. For direct mounting on NAMUR interface. Any position. Aluminium body. tainless steel is available. Dry or lubricated air. Min. 32 F (0 C) Max. 122 F (+ 50 C) ee information of coils. H HAN AN 24 VDC, 48 VDC, 110 AC, 220 AC ± 10% of nominal Working Principle B A A R P R P R NAMUR Interfaces T 1/4 1/2 D1 1/2 D1 in (mm) 1.26 (32) 1.77 (45) D2 D2 in (mm) 0.95 (24) 1.58 () T M T 1/4 M mm M5 M6 H 2W5 AN 2W3 2

3 N eries olenoid Valve olenoid Coil Width: 22 mm Connection Type: Industry Form Moulding Material: Thermoset Resin 11 M 3; 5 depth ø HA AN 10 ø8 11 General Data Voltage tolerance Ambient temperature Relative duty cycle Insulation class of insulating materials according to DIN VDE 0580 Degree of protection with connector according to EN Imprint (customer imprint - special version) Technical Data Voltage[V] 12DC 24DC 48DC 110AC 220AV Frequency[Hz] /60 50/60-10% ~+10% -20 C ~+50 C 100% F IP 65 / IP 67* Nass Magnet Output 4.6W 3.0W T.HAN TH N 2.7W 5.7/4.6VA 8.5/6.9VA 3

4 Valves, Actuators, Accessories olenoid Coil ystem 8 ATEX Widths : 22 mm Ex II 2G EEx m II T_/IEC Ex m II T_ Ex II 2D IP 65 T_ C/ IP65 DIP A21 T_ C Protection by Encapsulation Connection Type: Cable H05VV-F 3G1 Cable H05VV-F 3G1 standard length 3m HAN ø ø8 11 EC-Type Examination Certificate PTB 00 ATEX 2001X / IECEx PTB General Data Voltage tolerance Ambient temperature Relative duty cycle Insulation class of insulating materials according to DIN VDE0580 Degree of protection with connector to EN Moulding material Cable length(other cable lengths on request) Technical Data Width 22mm 22mm Voltage[V] 24DC 220AC -10% ~+10% -20 C ~+50 C 100% F IP 65 Thermoplastoc 3 m T THA T.H Frequency[Hz] - 50/60 Output 3.0W 5.1VA Temperature Class T4 T4 4

5 N eries olenoid Valve olenoid Coil ystem 8 ATEX ø8 pecial Version: ystem 8 Ex CA/FM Width : 36 mm Ex m II T4 + Division 1 31 ø AN 36 ø24.6 thread connection 1/2-NPT standard length 24" Connection Type : Flying Leads, Thread 1/2-NPT EC-Type Examination Certificate CA Hazardous Locations Ex m II T4 and division 1 - Class I, Group A, B, C and D - Class II, Group E, F and G - Class III Approved in compliance with CAN/ CA-E and CAN/ CA-E for CA, according to ANI/ IA and ANI/ IA for FM. General Data Voltage tolerance Ambient temperature Relative duty cycle Insulation class of insulating materials according to DIN VDE0580 Degree of protection with connector to EN Moulding material Cable length(other cable lengths on request) Technical Data Voltage[V] 24DC 220AC Frequency[Hz] - 50 Output 4.6W 7.7VA -10% ~+10% -20 C ~+60 C 100% H IP 65 Thermoplastoc 24Inch/0.6 m T. HAN Thread Connection Temperature Class tainless teel T4 tainless teel T4 5

6 Valves, Actuators, Accessories Dimension 2W W G1/8 5-G1/ T Ø H HA A H H Ø3.2 T35.0T H Ø3.2 2W G1/ W G1/ AN AN3 T.HA TH22H1H AN T.H TH HA A9A AN A Ø Ø3.2 If you enquire any further information, please do not hesitate to contact us. 6

7 N eries olenoid Valve Dimension W W T TH HA75 A W W G1/4 T.HAN THAN T H HA G1/4 5-G1/ If you enquire any further information, please do not hesitate to contact us T.HA 0T THAN HAN

8 Valves, Actuators, Accessories Dimension 2W W ØX1.4 2W W ØX H AN ØX1.4 N0X1.4 T.HAN H6H If you enquire any further information, please do not hesitate to contact us ØX1.4 NX1.4 T.HA.0AN N.0.0 NN

9 N eries olenoid Valve Dimension W L W L Ø T H2 Ø W L 57.0A63.0 T.HAN TH W L 5-G1/ G1/ T N G1/ If you enquire any further information, please do not hesitate to contact us. 7.5 TH74.9HHA 6.0 T.HA TH HAN 4.0 9

10 Valves, Actuators, Accessories How to Order UNIT CONTENT Control mode tandards Coil Type Connection Body Power Explosive-proofp CODE None 2W None AC 220 None EXAMPLE olenoid 2 way 5 Ports ingle NAMUR 1/4 Middle AC 220V None olenoid 2W3 2 way 3 Ports 1 NAMUR mall None A Air 2W5 2 way 5 Ports 2 PIPE None Middle EExm II T4 3W5 3 way 5 Ports L Large EExm II T5 NNone EExia II T6 08 1/8 1 ingle coil 10 1/4 ANall DC 24V 2 Double coils 15 1/2 DC48V HA1/8 AC 24V Other Brands 15A TH HAN LAN N THcoil AC 110V AC 220V Product code 2W AC220 ACO MC FETO PARKER NOGREN BURKERT 10

ü ( Explosion Protection

ü   ( Explosion Protection Explosion Protection ü www.nassmagnet.com ( +49 11 6746-0 Explosion Protection SOLENOID COILS FOR USE IN POTENTIALLY EXPLOSIVE ENVIRONMENTS nass magnet offers components of the series System 8 and System

More information

Glass-fibre-reinforced polycarbonate. Dead zone Adaptive or fixed from % 1.5 s adjustable. 20 ms. 60 ms. 60 ms. Approx. 1.

Glass-fibre-reinforced polycarbonate. Dead zone Adaptive or fixed from % 1.5 s adjustable. 20 ms. 60 ms. 60 ms. Approx. 1. General data Mounting On linear actuators On quarter turn actuators ARCA-integrated or to VDI/VDE 3847-1 or IEC 534-6 (NAMUR) Range of stroke: 3... 130 mm Integrated to VDI/VDE 3847-2 or VDI/VDE 3845 Angle

More information

FOR RELIABLY MEASURING +

FOR RELIABLY MEASURING + in(f)a22 ina05-09 ina14 PROXIMITY SWITCHES FOR RELIABLY MEASURING + EVALUATING MOVEMENTS T H E PROXIMITY SWITCHES O F T I E F E N B A C H C O N T R O L S Y S T E M S >>> HAVE BEEN ESPECIALLY DEVELOPED

More information

Technical Data. General specifications. Rated operating distance s n 3 mm

Technical Data. General specifications. Rated operating distance s n 3 mm 0102 Model Number Features Direct mounting on standard actuators Compact and stable housing with terminal compartment connection Fixed setting EC-Type Examination Certificate TÜV99 ATEX 1479X Usable up

More information

Glass-fibre-reinforced polycarbonate. Dead zone Adaptive or fixed from % 20 ms. 60 ms. 60 ms. Approx. 1.3 kg. Approx. 0.9 kg. Approx. 5.

Glass-fibre-reinforced polycarbonate. Dead zone Adaptive or fixed from % 20 ms. 60 ms. 60 ms. Approx. 1.3 kg. Approx. 0.9 kg. Approx. 5. General data Mounting On linear actuators On quarter turn actuators ARCA-integrated or to VDI/VDE 3847-1 or IEC 534-6 (NAMUR) Range of stroke: 3... 130 mm Integrated to VDI/VDE 3847-2 or VDI/VDE 3845 Angle

More information

KFS. Flap-type flow meter. Design and range of application

KFS. Flap-type flow meter. Design and range of application Design and range of application The measuring device operates largely independent of viscosity and is suitable for indicating the flow rate of water, acids, alkaline solutions and gases. Every device is

More information

Connection. Input EEx ia IIC. Sense. Fine tuning adjustment. Fine tuning amplifying. Amplifying. Adjustment. Output. Composition

Connection. Input EEx ia IIC. Sense. Fine tuning adjustment. Fine tuning amplifying. Amplifying. Adjustment. Output. Composition Converter Connection 1-channel EEx ia IIC for 4-wire and 6-wire bridges Analogue output 0/4 ma... 20 ma or 4mA...-12mA Full bridge load cells and strain gauges circuit for resistance bridges up to 17 Ω

More information

SITRANS F flowmeters. SITRANS F R Rotary-piston meters Accessory modules 4/431. Overview. Siemens AG 2009

SITRANS F flowmeters. SITRANS F R Rotary-piston meters Accessory modules 4/431. Overview. Siemens AG 2009 Siemens AG 2009 SITRANS F flowmeters Rotary-piston meters Accessory modules Accessory modules For quantity measurements in conjunction with electromechanical and electronic pulse counters As transmitter

More information

Single-Channel Safety Barriers Series 9001

Single-Channel Safety Barriers Series 9001 Single-Channel Safety Barriers Series 9001 > Broad product range for all standard applications in the world of automation > Flexible and space saving single and dual channel versions available > Time saving

More information

MJK Expert 700 / 800 / 900 / 1100 / 2100 MJK Expert 1400 / 3400

MJK Expert 700 / 800 / 900 / 1100 / 2100 MJK Expert 1400 / 3400 Data Sheet MJK Expert 700 / 800 / 900 / 1100 / 2100 MJK Expert 1400 / 3400 Submersible Hydrostatic s Rugged and versatile We reserve the right to continuously improve our products and make any change in

More information

The EVI 30/8 coils can be equipped with the suitable plunger guide tube (see S8 - S9 Catalogue).

The EVI 30/8 coils can be equipped with the suitable plunger guide tube (see S8 - S9 Catalogue). EVI 30 Coil System The EVI 30 system by Amisco includes a wide range of 30mm coils, designed for pneumatic applications. This coil family is available for tubes with 8, 9 and 10mm diameter. The coils are

More information

Ex-control switch Typ 294 without and Typ 295 with measuring instrument

Ex-control switch Typ 294 without and Typ 295 with measuring instrument Ex-control switch GHG 9 and GHG 9 GHG 9 GHG 9 Technical data Ex-control switch Typ 9 without and Typ 9 with measuring instrument with GHG 9 switch with GHG switch Marking accd. to 0//EU D II G Ex ed ia

More information

SOLENOIDS, COILS & ACCESSORIES Product Index

SOLENOIDS, COILS & ACCESSORIES Product Index SOLENOIDS, COILS & ACCESSORIES Product Index Description Series Page Coil identification Catalogue numbers of replacement coils SOLENOID OPERATORS Solenoid s, description and dimensions V1100-2/3 V1100-4..6

More information

Two-channel safety barriers Series 9002

Two-channel safety barriers Series 9002 Two-channel safety s Series 00 > Wide product range for all standard applications of the automation > Flexible and space-saving available in single and double channel versions > Time-saving installation

More information

Rod probe With coaxial tube reference probe

Rod probe With coaxial tube reference probe Capacitive level transmitters GENERAL DESCRIPTION NIVOCAP 2-wire capacitive level transmitters provide an ideal solution for level measurement of conductive or non-conductive liquids. The probe of the

More information

Valve Series V2001 Globe Valve Type 3321 with Pneumatic or Electric Actuator

Valve Series V2001 Globe Valve Type 3321 with Pneumatic or Electric Actuator Valve Series V2001 Globe Valve Type 3321 with Pneumatic or Electric Actuator ANSI version Application Control valves designed for mechanical and plant engineering. Suitable for liquids, gases and steam

More information

Two-channel safety barriers Series 9002

Two-channel safety barriers Series 9002 Two-channel safety s Series 00 > Wide product range for all standard applications of the automation > Flexible and space-saving available in single and double channel versions > Time-saving installation

More information

SALES SERVICE +358 (0)

SALES SERVICE +358 (0) SALES SERVICE +358 (0)17 262 3555 info@econosto.fi ADCATROL ELECTRO-PNEUMATIC POSITIONERS PE 986 (ATEX) DESCRIPTION The ADCATROL PE986 positioner requires an input signal of 4 20 ma for proportional control

More information

Resistance thermometers for process technology

Resistance thermometers for process technology Data Sheet 90.2820 Page 1/8 Resistance thermometers for process technology for temperatures from -200 to +600 C with protection tubes in stainless steel, titanium, tantalum, Iconel and Hastelloy available

More information

Electrical Temperature Measurement

Electrical Temperature Measurement Electrical Temperature Measurement Resistance Thermometers Model TR10-B, for Additional Thermowell Applications Machinery, plant and tank construction Energy and power plant technology Chemical industry

More information

Positive Displacement Flow sensors

Positive Displacement Flow sensors JJ Series VZGG JJ Series VZVA JJ Series VZAL JJ Local displays TD5 Positive Displacement Flow sensors DS_Positive_displacement_flow_sensors / 153 Positive displacement flow sensors Gearwheel type flow

More information

TIDALFLUX 2300 F Technical Datasheet

TIDALFLUX 2300 F Technical Datasheet Technical Datasheet Electromagnetic flow sensor for partially filled pipes Measurement in partially filled pipes up to DN1600 / 64" Patented, non-contact level measurement Measurement possible down to

More information

Positioner with HART Communication Type 3780

Positioner with HART Communication Type 3780 Positioner with HART Communication Type 780 Application Single-acting or double-acting positioner for attachment to pneumatic control valves. Supplied with an electric input signal from to 20 ma Travels

More information

M224. M C bis. TYPE CODE M K Y 45 / 18 x 60 - / / / - #

M224. M C bis. TYPE CODE M K Y 45 / 18 x 60 - / / / - # Solenoid coil MKY/18x60 For explosion-hazard zones Protection class IP65/66/67 Optional with integrated amplifier electronics Ex db IIC T6 / T4 Gb Ex tb IIIC IP65 T80 C/T130 C Db Ex db I Mb II 2 G Ex db

More information

PNEUMATIC, ELECTRO-PNEUMATIC & SMART DIGITAL.

PNEUMATIC, ELECTRO-PNEUMATIC & SMART DIGITAL. PNEUMATIC, ELECTRO-PNEUMATIC & SMART DIGITAL www.unitorq.com UT-1000 Electro-Pneumatic Positioners Linear & Rotary Unmatched Stability in Tough Environments. UniTorq s advanced-control electro-pneumatic

More information

Explosion proof rotary actuator - On/Off or programmable regulating actuator

Explosion proof rotary actuator - On/Off or programmable regulating actuator Explosion proof rotary actuator - On/Off or programmable regulating actuator Direct mounting for quarter-turn valves Manual override standard Corrosion resistant Adjustable limit switches Type 3004 can

More information

Field indicator for current loops with HART communication Models DIH50, DIH52

Field indicator for current loops with HART communication Models DIH50, DIH52 Accessories Field indicator for current loops with HART communication Models DIH50, DIH52 WIKA data sheet AC 80.10 for further approvals see page 6 Applications Process engineering Plant construction General

More information

Isolators A3/1. Ex i Power Supply Field Circuit Ex i Series

Isolators A3/1. Ex i Power Supply Field Circuit Ex i Series > Intrinsically safe output [Ex ib] IIC/IIB > Stable output voltage > Galvanic isolation between output and power supply > Power supply or 85... 230 V AC > Compact design www.stahl.de 07673E00 Basic function:

More information

Level Limit Switch nivotester FTL 370, FTL 372

Level Limit Switch nivotester FTL 370, FTL 372 Technical Information TI 98F/00/en Limit Switch nivotester FTL 370, FTL 37 With intrinsically-safe signal circuits for connection to sensors Liquiphant, Nivopuls, Soliphant. Features at a Glance High operational

More information

... for hydraulic and general applications in hazardous areas

... for hydraulic and general applications in hazardous areas ATEX Approved Inductive... for hydraulic and general applications in hazardous areas Inductive Namur sensors Explosion protected Ignition class "intrinsically safe" when used together a suitable certified

More information

2-way pilot operated solenoid valves for water, hot water and steam

2-way pilot operated solenoid valves for water, hot water and steam 2-way pilot operated solenoid valves for water, hot water and steam Catalogue 8658/GB NEW Also available with ATEX Explosion-proof electrical parts Technical specifications General description Applications

More information

Assembly. Front view. LED yellow: Relay output. LED red: LB/SC

Assembly. Front view. LED yellow: Relay output. LED red: LB/SC Switch Amplifier Features Assembly -channel isolated barrier 30 V AC supply Dry contact or NAMUR inputs Relay contact output Line fault detection (LFD) Reversible mode of operation Up to SIL acc. to IEC

More information

Single-Channel Safety Barriers with Electronic Current Limitation Series 9004

Single-Channel Safety Barriers with Electronic Current Limitation Series 9004 Single-Channel Safety Barriers with Electronic Current Limitation > Broad product range for all standard applications in the world of automation > Flexible and space saving > Time saving installation due

More information

Rosemount 848L Logic Transmitter with FOUNDATION Fieldbus

Rosemount 848L Logic Transmitter with FOUNDATION Fieldbus Logic Transmitter with FOUNDATION Fieldbus Integrates Discrete I/O on a FOUNDATION Fieldbus H1 Segment Reduces Installation and Maintenance Costs with a Single Network for Analog and Discrete devices Easily

More information

2/2-Way Solenoid Control Valve

2/2-Way Solenoid Control Valve 2/2-Way Solenoid Control Valve Excellent range (1:200) Very good response Compact valve design Orifice sizes 0.8... 4 mm Port connection 1/8, 1/4 or sub-base Type 2873 can be combined with Type 8605 Digital

More information

2 Safety Barriers. Single-Channel Safety Barriers with Electronic Current Limitation Series 9004

2 Safety Barriers. Single-Channel Safety Barriers with Electronic Current Limitation Series 9004 2 Safety Barriers Single-Channel Safety Barriers with Electronic Current Limitation Series 9004 Broad product range for all standard applications in the world of automation Flexible and space saving Time

More information

IP26 Series Current to Pneumatic Converter

IP26 Series Current to Pneumatic Converter Product Specifications 06.2016 PSS EVE0403 A-(en) IP26 Series Current to Pneumatic Converter The IP26 (current to pressure) transducer converts a 4 20mA electrical current signal to a proportional linear

More information

Isolators Isolating Repeater Field Circuit Ex i ISpac 9165/ s Art. No

Isolators Isolating Repeater Field Circuit Ex i ISpac 9165/ s Art. No 9165/16-11-10s 207909 Compact one- and two-channel Ex i output isolating repeater wire-breakage and short-circuit monitoring system, which can be disconnected and features a signalling contact can be used

More information

Limit switch attachments DAPZ

Limit switch attachments DAPZ Type codes DAPZ SB M 250AC DR AR Type DAPZ Limit switch attachment Specification SB Sensor box Measuring principle I M Inductive Electrical, micro switch Operating voltage 25DC 30DC 250AC 8 V DC 30 V DC

More information

OPTIWAVE 1010 Technical Datasheet

OPTIWAVE 1010 Technical Datasheet OPTIWAVE 1010 Technical Datasheet Radar (FMCW) Level Transmitter for bypass chambers and magnetic level indicators (BM 26 Advanced) Device welded to a bypass chamber with an optional IP68 level indicator

More information

Target disk flowmeter for liquids and gases

Target disk flowmeter for liquids and gases Target disk flowmeter for liquids and gases Metallic, simple and robust construction Available for all flow directions Suitable for extreme pressure and temperature conditions Low pressure drop Straight

More information

RHE12. Hazardous Area Coriolis Mass Flow Transmitter. Features. Applications. Benefits

RHE12. Hazardous Area Coriolis Mass Flow Transmitter. Features. Applications. Benefits RHE12 Hazardous Area Coriolis Mass Flow Transmitter Features Field mounting Compact, pressure safe housing ATEX and CSA approvals for installation in hazardous areas 24 VDC power supply Configurable analog

More information

Coriolis Massflowmeter

Coriolis Massflowmeter Coriolis Massflowmeter for liquids and gas measuring monitoring analysing Measuring range: 0-60 kg/h 0-60 000 kg/h water Accuracy: ±0,15 of reading ±zero-point stability pmax: PN40 tmax: -40 +180 C Connection:

More information

Field indicator for current loops with HART communication Models DIH50, DIH52

Field indicator for current loops with HART communication Models DIH50, DIH52 Accessories Field indicator for current loops with HART communication Models DIH50, DIH52 WIKA data sheet AC 80.10 for further approvals see page 7 Applications Process engineering Plant construction General

More information

OPTIFLUX 5000 Technical Datasheet

OPTIFLUX 5000 Technical Datasheet OPTIFLUX 5000 Technical Datasheet Electromagnetic flowmeter in flanged version Exceptional long-term stability and accuracy For highly aggressive and abrasive fluids Fully vacuum-resistant with high-tech

More information

Coriolis Massflowmeter

Coriolis Massflowmeter Coriolis Massflowmeter for liquids and gas measuring monitoring analysing Measuring range: 0-0.8 kg / h 0-65 000 kg / h water Accuracy: ± 0.1 of reading ±zero-point stability (liquids) pmax: PN40 tmax:

More information

Inductive sensor slot-type SI2-K08-AP7

Inductive sensor slot-type SI2-K08-AP7 SI2-K08-AP7 Slot sensor, height 8 mm Plastic, polypropylene Mechanical end stop, removable, for analog pointer instruments 3-wire DC, 10 30 VDC NO contact, PNP output Cable connection Wiring diagram Type

More information

Local control stations for Zone 1 and Zone 21. Features. Description

Local control stations for Zone 1 and Zone 21. Features. Description Local control stations for Zone and Zone Local control stations for Zone and Zone Features The right size/material enclosure Optimum functionality thanks to the great variety of components Customised planning

More information

Remote Switching Unit nivotester FTL 320

Remote Switching Unit nivotester FTL 320 Technical Information TI 203F/24/ae Remote Switching Unit nivotester For connection to intrinsically safe Liquiphant level limit switches Applications Limit detection of fluids and bulk solids in tanks

More information

SITRANS T measuring instruments for temperature

SITRANS T measuring instruments for temperature Overview Our field devices for heavy industrial use HART, Universal 4 to 20 ma, universal Field indicator for 4 to 20 ma signals The temperature transmitter SITRANS TF works where others feel uncomfortable.

More information

Metal tube variable area flowmeters for gases, liquids and steam

Metal tube variable area flowmeters for gases, liquids and steam Metal tube variable area flowmeters for gases, liquids and steam Metallic with a robust construction, optional in plastic Indication by means of magnetic coupling Linear scales, calibrated in l/h, m3/h,

More information

Any installation position possible. 1K5, but C. < 2 % of the control range. < 0,2 % / 0,1 bar, type 824.P < 0,1 % / 0,1 bar. Approx.

Any installation position possible. 1K5, but C. < 2 % of the control range. < 0,2 % / 0,1 bar, type 824.P < 0,1 % / 0,1 bar. Approx. General data Mounting Enclosure material On linear actuators On quarter-turn actuators ARCA-integrated or acc. to IEC 534-6 (NAMUR) Range of stroke 10... 120 mm ARCA-integrated or acc. to VDI/VDE 3845

More information

Coil. Coil L 12 VDC 135 C 18 W 7.7 Ω M M 24 VDC 135 C 18 W 31 Ω M AMP Junior (AJ variant) Coil

Coil. Coil L 12 VDC 135 C 18 W 7.7 Ω M M 24 VDC 135 C 18 W 31 Ω M AMP Junior (AJ variant) Coil s W COILS Type of protection IP 65 Ambient -30 C 60 C F 0.141 kg 42 12 Ø13.25 30 38.6 ISO 4400 (DIN 43650) 17 21.5 20.5 STANDARD irschmann ISO 4400 DIN43650 L 12 VDC 135 C W 7.7 Ω M14000001 M 24 VDC 135

More information

SOLENOID VALVES pilot operated, spool type single/dual solenoid (mono/bistable function) aluminium body, NAMUR style, 1/4-1/2

SOLENOID VALVES pilot operated, spool type single/dual solenoid (mono/bistable function) aluminium body, NAMUR style, 1/4-1/2 SOLENOI VLVES pilot operated, spool type single/dual solenoid (mono/bistable function) aluminium body, NMUR style, / - / 0 / / Series - FETURES The monostable spool valves in conformity with IE 608 Standard

More information

Resistance thermometer Model TR30, compact design

Resistance thermometer Model TR30, compact design Electrical temperature measurement Resistance thermometer Model TR30, compact design WIKA data sheet TE 60.30 Applications Machine building, plant and vessel construction Propulsion technology, hydraulics

More information

Base Mounted Plug-in Unit

Base Mounted Plug-in Unit For details about certified products conforming to international standards, visit us at www.smcworld.com. 000 Plug-in Unit SI unit COM N V V C C C6 M CM 6 B B B6 B M 000 Manifold model Plug-in unit Stations

More information

TMU. Coriolis Mass Flow Meter. for liquids and gas

TMU. Coriolis Mass Flow Meter. for liquids and gas Coriolis Mass Flow Meter for liquids and gas measuring monitoring analysing TMU S5 OO Measuring range: 0-60 kg/h 0-2200 t/h water OO Accuracy: ± 0.1% of reading ±zero point stability (from liquids up to

More information

Intrinsically Safe Pressure Transmitter for applications in hazardous environments and shipbuilding industry Model IS-20-S, IS-21-S, IS-20-F, IS-21-F

Intrinsically Safe Pressure Transmitter for applications in hazardous environments and shipbuilding industry Model IS-20-S, IS-21-S, IS-20-F, IS-21-F Replacement product: Model IS-3 Electronic Pressure Measurement Intrinsically Safe Pressure Transmitter for applications in hazardous environments and shipbuilding industry Model IS-20-S, IS-21-S, IS-20-F,

More information

All TXI7850 products are ROHS compliant.

All TXI7850 products are ROHS compliant. Features Explosion-proof NEMA 4X, IP65, Type 4 enclosure for outdoor and indoor installations. Optional tapped exhaust port vents exhaust gas. Canadian Registration Numbers (CRN) certification for all

More information

SINEAX TV 808, 1 channel Isolating Amplifier, output Ex or non-ex

SINEAX TV 808, 1 channel Isolating Amplifier, output Ex or non-ex for electrically insulating, amplifying and converting DC signals, also designed for FSK 1 0102 II (1) G Application The purpose of the isolating amplifi er SINEAX TV 808 (Fig. 1) is to electrically insulate

More information

Resistance thermometer Model TR30, compact design

Resistance thermometer Model TR30, compact design Electrical temperature measurement Resistance thermometer Model TR30, compact design WIKA data sheet TE 60.30 Applications Machine building, plant and vessel construction Propulsion technology, hydraulics

More information

IFC 100 Technical Datasheet

IFC 100 Technical Datasheet IFC 100 Technical Datasheet Signal converter for electromagnetic flowmeters Simple and easy to install and start-up Diagnostics of device and application Extremely fast signal conversion The documentation

More information

How to Order Manifold. Manifold mounting. DIN rail mounting style Direct mounting style

How to Order Manifold. Manifold mounting. DIN rail mounting style Direct mounting style Plug Lead Unit Series 000 [Option] How to Order Manifold S 0 FD D Electrical entry F kit D-sub connector kit P kit Kit type Flat ribbon cable connector kit J kit Flat ribbon cable (0P) (PC Wiring System

More information

Advantages. Applications

Advantages. Applications 3 s KH 250 General Data Rated input voltage 2 Vac Rated output voltage 2 Vac Rated power 250 VA Ambient temperature +40 C Degree of protection IP 40 Advantages Compensation for mains voltage fluctuations

More information

OEM radar transmitter, for aggressive media level measurement

OEM radar transmitter, for aggressive media level measurement OEM radar transmitter, for aggressive media level measurement C ompact for level measurement up to 20 m 4... 20 ma/hart - 2 wires Adjustable with P C ATEX approvals Type 8136 can be combined with... Type

More information

SINEAX TI 807 Passive DC signal isolator

SINEAX TI 807 Passive DC signal isolator without power supply, Ex- and non-ex version, in housing N17 or S17 for rail and wall mounting 0102 II (1) G resp. II (2) G Application The signal isolator SINEAX TI 807 serves to electrically insulate

More information

Resistance Thermometers Model Series TR7X0, Sheathed Design

Resistance Thermometers Model Series TR7X0, Sheathed Design Electrical Temperature Measurement Resistance Thermometers Model Series TR7X0, Sheathed Design WIKA Data Sheet TE 60.40 Applications T Suitable for all industrial and laboratory applications Special Features

More information

MBC /602(L) MBC /602(L) MBC /602(L)

MBC /602(L) MBC /602(L) MBC /602(L) GasMultiBloc Combined servo pressure regulator and safety shut-off valves MBC-... 1000/60(L) MBC-... 500/60(L) MBC-... 4000/60(L) Two normally closed automatic shutoff valves and servo regulator in one

More information

Float Switches with Permanent Magnet For Vertical Installation Model RSM

Float Switches with Permanent Magnet For Vertical Installation Model RSM Level Measurement Float Switches with Permanent Magnet For Vertical Installation Model RSM WIKA Data Sheet LM 30.01 Applications Level measurement for almost all liquid media Pump/level control and monitoring

More information

Miniature resistance thermometer Explosion-protected version Model TR34, thread-mounted

Miniature resistance thermometer Explosion-protected version Model TR34, thread-mounted Electrical temperature measurement Miniature resistance thermometer Explosion-protected version Model TR34, thread-mounted WIKA data sheet TE 60.34 Applications Machine building, plant and vessel construction

More information

SS2 Linear / Rotary. Smart Valve Positioner. Smart performance with innovative and ever-strong coil drive even under harsh working environments

SS2 Linear / Rotary. Smart Valve Positioner. Smart performance with innovative and ever-strong coil drive even under harsh working environments Smart Valve Positioner SS2 Linear / Rotary Smart performance with innovative and ever-strong coil drive even under harsh working environments Easy and quick auto-calibration Detecting RA (reverse acting)

More information

TQ 401 / EA 401 / IQS 451. Proximity System : TQ 401 Proximity Transducer EA 401 Extension Cable IQS 451 Signal Conditioner FEATURES

TQ 401 / EA 401 / IQS 451. Proximity System : TQ 401 Proximity Transducer EA 401 Extension Cable IQS 451 Signal Conditioner FEATURES Proximity System : TQ 401 Proximity Transducer EA 401 Extension Cable IQS 451 Signal Conditioner FEATURES Non-contacting measurement system based on eddy current principle Certified for use in potentially

More information

Relative and absolute pressure transmitter type 528

Relative and absolute pressure transmitter type 528 Relative and absolute pressure transmitter type 528 The compact type 528 pressure transmitter is based upon the Huba Control developed and since over 20 years well proven ceramic technology. These transmitters

More information

Level Switch Catalogue

Level Switch Catalogue Level Switch Catalogue 2 www.besta.ch 3 Table of contents Worldwide in use Trimod Besta Level Switches 4 Worldwide approved Approvals 5 Quality for your safety Modular flexibility Mounting combinations

More information

Type PLC Fitting. Valve for Continuous control. Diaphragm valve. Output

Type PLC Fitting. Valve for Continuous control. Diaphragm valve. Output Digital Inductive conductivity transmitter Optimal solution for conductivity measurements in difficult fluids (polluted, dirty,...) PEEK/PPA version for CIP applications Large range of process connections

More information

DMP 343. Industrial Pressure Transmitter. Without Media Isolation. appmeas.co.uk +44 (0)

DMP 343. Industrial Pressure Transmitter. Without Media Isolation. appmeas.co.uk +44 (0) DMP 4 Industrial Pressure Transmitter Without Media Isolation accuracy according to IEC 60770: 0.5 % FSO Nominal pressure from 0... 0 mbar up to 0... 000 mbar Product characteristics excellent linearity

More information

Isolating Spark Gaps. Isolating spark gaps at an additional earth ring conductor. Isolating spark gaps for Ex zones

Isolating Spark Gaps. Isolating spark gaps at an additional earth ring conductor. Isolating spark gaps for Ex zones Isolating Spark Gaps Isolating spark gaps at an additional earth ring conductor Isolating spark gaps for Ex zones 187 Protective Spark Gaps For use at roof supports for overhead lines For indirect connection

More information

Echotel Model 910 Ultrasonic Level Switch

Echotel Model 910 Ultrasonic Level Switch Echotel Model 910 Ultrasonic Level Switch D E S C R I P T I O N Echotel Model 910 Level Switches utilize ultrasonic contact technology for measuring level in clean liquid applications. The dual conduit

More information

Preset counters, electronic

Preset counters, electronic The Codix 716 / 717 can be used universally. These preset pulse, tachometers or preset timers with up to 2 presets can solve a wide variety of control and monitoring tasks in every application. With their

More information

Installation guide 971 SmartRadar LTi

Installation guide 971 SmartRadar LTi Installation guide 971 SmartRadar LTi March 2009 Part no. 4416.715 Revision 3 Enraf B.V. P.O. Box 812 2600 AV Delft Netherlands Tel. : +31 15 2701 100 Fax : +31 15 2701 111 E-mail : enraf-nl@honeywellenraf.nl

More information

SINEAX TV 808, 1 channel Isolating Amplifier unipolar/bipolar

SINEAX TV 808, 1 channel Isolating Amplifier unipolar/bipolar For electrically insulating, amplifying and converting DC signals 0102 II (1) G Application The purpose of the isolating amplifi er SINEAX TV 808 (Fig. 1 and 2) is to electrically insulate input and output

More information

Remote I/O. 74 Remote I/O. Remote I/O System

Remote I/O. 74 Remote I/O. Remote I/O System System Overview of the System Components IS1+ 76 General Information IS1+ 77 CPU & Power Modules CPU & Power Modules for Zone 1 / Div. 1 IS1+ 9440/22 78 Sockets for CPU & Power Module IS1+ 9490 78 CPU

More information

Technical Information Nivector FTC968, FTC968Z

Technical Information Nivector FTC968, FTC968Z TI0007F/00/EN/7.6 7494 Products Solutions Services Technical Information Nivector FTC968, FTC968Z Capacitance Point level switch for powder and fine-grained bulk solids Application The Nivector is a small-sized

More information

The T6000 Series Electro-Pneumatic Transducer converts a DC current or voltage input signal to a directly proportional pneumatic output.

The T6000 Series Electro-Pneumatic Transducer converts a DC current or voltage input signal to a directly proportional pneumatic output. GENERAL INFORMATION T6000 SERIES TRANSDUCER Electro-Pneumatic (I/P, E/P) APPLICATIONS The T6000 Series Electro-Pneumatic Transducer converts a DC current or voltage input signal to a directly proportional

More information

BATCHFLUX 5500 C Technical Datasheet

BATCHFLUX 5500 C Technical Datasheet BATCHFLUX 5500 C Technical Datasheet Electromagnetic flowmeter for volumetric filling machines High-stability ceramic measuring tube, therefore extremely long-term stability Optimum hygienic design Only

More information

OPTIFLUX 5000 Technical Datasheet

OPTIFLUX 5000 Technical Datasheet OPTIFLUX 5000 Technical Datasheet Electromagnetic flowmeter in flanged version Exceptional long-term stability and accuracy For highly aggressive and abrasive fluids Fully vacuum-resistant with high-tech

More information

TQ 402 & TQ 412 / EA 402 / Proximity System : TQ 402 & TQ 412 Proximity Transducers EA 402 Extension Cable IQS 452 Signal Conditioner FEATURES

TQ 402 & TQ 412 / EA 402 / Proximity System : TQ 402 & TQ 412 Proximity Transducers EA 402 Extension Cable IQS 452 Signal Conditioner FEATURES : TQ 402 & TQ 412 Proximity Transducers EA 402 Extension Cable IQS 452 Signal Conditioner TQ 402 & TQ 412 / EA 402 / IQS 452 FEATURES Non-contacting measurement system based on eddy current principle Certified

More information

Digital I/O Coupler (4-wire) Series 9413/21

Digital I/O Coupler (4-wire) Series 9413/21 Digital /O Coupler (4wire) > The digital /O coupler is used to connect 8 intrinsically safe contacts or proximity initiators and 4 intrinsically safe solenoid valves to a FOUNDATON TM fieldbus H1. > Galvanic

More information

FAS 10 mm PICOSOL Direct acting solenoid valve

FAS 10 mm PICOSOL Direct acting solenoid valve FS 0 mm PICOSOL > > /, /; Manifold mounting > > Long life 00 million cycles > > Compact Design > > Low power consumption Technical features Medium: ir, oxygen, neutral gases (0 %... 9 % humidity, non condensing),

More information

Density meter DWF. Device description. Device description DWF Page 1 of 22

Density meter DWF. Device description. Device description DWF Page 1 of 22 Density meter DWF Device description Device description DWF Page 1 of 22 Table of Contents 1. Definition of the device 4 1.1 Vendor / Manufacture 4 1.2 Product type and designation 4 1.3 Manual issue date

More information

Signal Beacon - LED Series 6162

Signal Beacon - LED Series 6162 www.stahl.de > Versions rotating mirror beacon rotating beacon beacon with double flash (9 + 5 J) flashing beacon (15 J) LED-continuous beacon LED-rotating beacon > Seawater resistant aluminium enclosure

More information

Electromagnetic Flow Measuring System Two-wire, loop-powered PROline promag 23 P

Electromagnetic Flow Measuring System Two-wire, loop-powered PROline promag 23 P Technical Information TI 049D/06/en 50097005 Electromagnetic Flow Measuring System Two-wire, loop-powered PROline promag 23 P Flow rate measurement in chemical or process applications Features and benefits

More information

Directional control valves, direct operated, with electrical position feedback and integrated electronics (OBE)

Directional control valves, direct operated, with electrical position feedback and integrated electronics (OBE) Directional control valves, direct operated, with electrical position feedback and integrated electronics (OBE) Type 4WRPEH RE 29035 Edition: 2017-04 Replaces: 2015-02 Size 6 Component series 2X Maximum

More information

FBCon. Contents. FBCon. FBCon H.1. Introduction H.2 PROFIBUS-DP H.5 PROFIBUS-PA H.8 PROFIBUS-PA ATEX H.26. Fieldbus Foundation H.33. FBCon DK6 H.

FBCon. Contents. FBCon. FBCon H.1. Introduction H.2 PROFIBUS-DP H.5 PROFIBUS-PA H.8 PROFIBUS-PA ATEX H.26. Fieldbus Foundation H.33. FBCon DK6 H. Contents Introduction.2 PROFIU-DP.5 PROFIU-P.8 PROFIU-P TEX.26 Fieldbus Foundation.33 DK6.36 ccessories.40.1 Introduction Overview T.2 Introduction ystem description, fieldbus components fieldbus distributors

More information

Ultrasonic level measuring device, non-contact

Ultrasonic level measuring device, non-contact Ultrasonic level measuring device, non-contact For level measurement up to 8 m 4... 20 ma/hart - 2 wires Suitable for solids ATEX approvals Type 8177 can be combined with... Type 8611 Type 8793 Type 8802-GB

More information

Directional valves Coils Series CO1. Brochure

Directional valves Coils Series CO1. Brochure Directional valves Coils Series CO1 Brochure 2 Directional valves Coils Series CO1 Form C, coil kit Coil width 15 mm 3 M8, coil kit Coil width 15 mm 5 form B Coil width 22 mm 7 Form B, industry Coil width

More information

SOLENOID TYPE, CERTIFICATION & PROTECTION CONCEPTS

SOLENOID TYPE, CERTIFICATION & PROTECTION CONCEPTS SOLENOID TYPE, CERTIFICATION & PROTECTION CONCEPTS Highlights in this presentation. 1. Have received BIS Approval for 62, 66, 67, 67L, 71 & 71L. 2. CCOE for the same is under process. 3. UL 1203 Approval

More information

Data Sheet KFD2-UFC-EX1.D. Supplied by. .com. Call us on +44 (0)

Data Sheet KFD2-UFC-EX1.D. Supplied by. .com. Call us on +44 (0) Data Sheet KFD-UFC-EX1.D Supplied by.com Call us on +44 (0)118 916 940 Email info@47able.com Frequency Converter with Trip Values Features Assembly 1-channel isolated barrier 4 V DC supply (Power Rail)

More information

Directional valves Electrically operated Series 563, 565, 567. Brochure

Directional valves Electrically operated Series 563, 565, 567. Brochure Directional valves Electrically operated Brochure 2 Directional valves Electrically operated 3/2-directional valve, Series 563 Qn = 1350 l/min plate connection Electr. connection: Plug, Form B, industry

More information

INSTALLATION AND OPERATION MANUAL

INSTALLATION AND OPERATION MANUAL Version 2.2 MS1016 MTF SERIES VIBRATING PROBES FOR LIQUIDS AND HYC-PKK-312 SWITCHING ISOLATOR INSTALLATION AND OPERATION MANUAL Hycontrol Limited, Larchwood House, Orchard Street, Redditch, Worcestershire,

More information