1 GENERAL DWG Nb. DRAWING TITLE L1702D-LOD- LIST OF DRAWINGS L1702D-GN- GENERAL & L1702D-WW-GNL-01 SEWER LINES - GENERAL LAYOUT L1702D-WW-KPL-01 SEWER LINES - GENERAL KEY PLAN L1702D-SW-GNL-01 STORM LINES - GENERAL LAYOUT L1702D-SW-KPL-01 STORM LINES - GENERAL KEY PLAN PLANS DWG Nb. DRAWING TITLE L1702D-WW-PL-01 SEWER LINES - PLANS (1 OF 3) L1702D-WW-PL-02 SEWER LINES - PLANS (2 OF 3) L1702D-WW-PL-03 SEWER LINES - PLANS (3 OF 3) L1702D-SW-PL-01 STORM LINES - PLANS (1 OF 3) L1702D-SW-PL-02 STORM LINES - PLANS (2 OF 3) L1702D-SW-PL-03 STORM LINES - PLANS (3 OF 3) PROFILES DWG Nb. DRAWING TITLE L1702D-WW-PR-01 SEWER LINES - PROFILES (1 OF 3) L1702D-WW-PR-02 SEWER LINES - PROFILES (2 OF 3) L1702D-WW-PR-03 SEWER LINES - PROFILES (3 OF 3) L1702D-SW-PR-01 STORM LINES - PROFILES (1 OF 2) L1702D-SW-PR-02 STORM LINES - PROFILES (2 OF 2) L1702D-SW-PR-03 STORM LINES - PROFILES (3 OF 3) LIST OF DRAWINGS SEWER TYPICAL DETAILS DWG Nb. DRAWING TITLE L1702D-WW-DT-01 PIPE BEDDING DETAILS (1 of 3) L1702D-WW-DT-02 PIPE BEDDING DETAILS (2 of 3) L1702D-WW-DT-03 PIPE BEDDING DETAILS (2 of 3) L1702D-WW-DT-04 FLEXIBLE JOINT DETAILS - SEALING METHOD L1702D-WW-DT-05 MANHOLES DETAILS (1 OF 4) L1702D-WW-DT-06 MANHOLES DETAILS (2 OF 4) L1702D-WW-DT-07 MANHOLES DETAILS (3 OF 4) L1702D-WW-DT-08 MANHOLES DETAILS (4 OF 4) L1702D-WW-DT-09 CROSSINGS DETAILS L1702D-WW-DT-10 INSPECTION CHAMBER L1702D-WW-DT-11 HOUSE CONNECTION DETAILS (1 OF 3) L1702D-WW-DT-12 HOUSE CONNECTION DETAILS (2 OF 3) L1702D-WW-DT-13 HOUSE CONNECTION DETAILS (3 OF 3) L1702D-WW-DT-14 PIPE ANCHORING DETAILS STORM TYPICAL DETAILS DWG Nb. DRAWING TITLE L1702D-SW-DT-01 TYPICAL TRENCHES DETAILS L1702D-SW-DT-02 STORM WATER MANHOLE DETAIL L1702D-SW-DT-03 GULLY & GULLY MANHOLE DETAILS L1702D-SW-DT-04 PIPE BEDDING REQUIREMENTS MRAYJE ION DRAWN BY: DESIGNED BY: CHECKED BY: APPROVED BY: PROJECT MANAGER : A.S JOB NUMBER : L01702 DATE LIST OF DRAWINGS -- L1702D-LOD-

2 GENERAL 1- DO NOT FROM DRAWINGS, ALL DIMENSIONS SHOULD BE READ OR COMPUTED. 2- THE CONTRACTOR SHALL ENSURE THE STABILITY AND SAFETY OF EXCAVATIONS AND SHALL TAKE ALL MEASURES NECESSARY TO ENSURE THAT NO COLLAPSE OR SUBSIDENCE OCCURS. 3- THE SIDES OF ALL EXCAVATIONS SHALL BE KEPT TRUE AND SHALL WHERE NECESSARY BE ADEQUATELY SUPPORTED BY MEANS OF TIMBER, STEEL OR OTHER TYPE STRUTS, WALINGS POLING BOARDS, SHEETING, BRACING AND THE LIKE. SUPPORTING EXCAVATION COST SHALL BE DEEMED INCLUDED IN THE UNIT RATE. 4- EXCAVATIONS SHALL BE KEPT FREE FROM WATER AND IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO CONSTRUCT AND MAINTAIN TEMPORARY DIVERSION AND DRAINAGE WORKS AND TO CARRY OUT PUMPING AND TO TAKE ALL MEASURES NECESSARY TO COMPLY WITH THIS REQUIREM 5- THE CONTRACTOR SHALL COMPLETE DETAILED DESIGN OF STRUCTURAL COMPONENTS AND PREPARE CONSTRUCTION SHOP DRAWINGS FOR ALL WORKS GIVEN IN THE CONTRACT. THE CONTRACTOR SHALL SUBMIT HIS PROPOSAL FOR THE ENGINEER'S APPROVAL IN COMPLETE SUBMITTAL PACKAGES IN A FORM THAT CAN BE COMPREHENSIVELY IEWED BY THE ENGINEER. CONSTRUCTION SHALL NOT COMMENCE BEFORE THE RECEIPT OF APPROVAL OF THE RELEVANT CONSTRUCTION DOCUMENTS. 6- MAIN BACKFILLING MATERIALS: - BACKFILL SHALL BE LAID AND WELL COMPACTED IN LAYERS NOT EXCEEDING 2mm THICK. COMPACTED TO 95% OF PROCTOR MAXIMUM DRY DENSITY BY A COMPACTING MACHINES SUITABLE FOR TRENCH WIDTH. - DO NOT USE HEAVY COMPACTORS OVER PIPE TRENCH UNTIL THERE IS 60mm (OR REQUIRED BY THE PIPE SUPPLIER) COVER OVER THE PIPE. - IF THE COVER OVER THE TOP OF THE PIPE IS LESS THAN 10mm (OR AS REQUIRED BY THE PIPE SUPPLIER), USE CONCRETE ENCASEMENT AS SPECIFIED ON THE DRAWING AND DIRECTED BY THE ENGINEER. - WHEN BACKFILLING TO PIPES WITH CONCRETE BEDS AND SURROUNDS, DO NOT START BACKFILLING BEFORE 24 HOURS OR ALLOW HEAVY COMPACTORS AND TRAFFIC OVER THE PIPES BEFORE 72 HOURS OF PLACING CONCRETE. 7- REINFORCEMENT: - UNLESS OTHERWISE NOTED ON THE DRAWINGS, ALL REINFORCEMENT INCLUDING TIES AND STIRRUPS SHALL BE HIGH TENSILE, THE FOLLOWING STANDARD ABBIATIONS ARE USED IN CALLING UP GRADES OF REINFORCEMENT: - HIGH TENSILE STEEL BARS : HA or T - MILD STEEL BARS : Ø STEEL HAVING A MINIMUM YIELD STRESS = 42 Kg/cm2. - UNLESS OTHERWISE NOTED, SPLICE LENGTHS SHALL BE 50Ø. 8- CONCRETE COVER: - THE MINIMUM CONCRETE PROTECTIVE COVER FOR REINFORCEMENT SHALL BE AS FOLLOWS: a) 3 CM FOR DECK SLAB b) 5CM FOR ALL MANHOLES, FOUNDATIONS AND WALLS - CLASS F( 2FAIR FACING) FORM WORK SHALL BE APPLIED FOR ALL INTERNAL CONCRETE SURFACES, OTHER WISE AS SHOWN ON DRAWINGS OR AS DIRECTED BY THE ENGINEER. - TWO COATS OF BITUMINOUS PAINT SHALL BE APPLIED TO ALL EXTERNAL CONCRETE SURFACES IN DIRECT CONTACT WITH EARTH. - TWO COATS OF COAL TAR EPOXY PAINT SHALL BE APPLIED TO ALL INTERNAL CONCRETE SURFACES OF ALL TYPES OF SEWER MANHOLES, INSPECTION CHAMBERS. 9- GEOTECHNICAL INVESTIGATION: - THE CONTRACTOR HAS TO CONDUCT HIS OWN GEOTECHNICAL INVESTIGATIONS AND TO PROPOSE COMPLETE FINAL DESIGN WITH CALCULATION SHEETS AND DRAWINGS FOR ALL STRUCTURAL COMPONENTS TO BE APPROVED BY THE ENGINEER. - IF SOIL IS NOT SUITABLE FOR THE ALLOWABLE AVERAGE TOE PRESSURE, MASS CONCRETE TO REQUIRED DEPTH IS TO BE CAST UNDER FOOTING AS INSTRUCTED BY ENGINEER. 10- CONCRETE: - ALL CLASSES OF CONCRETE ARE TO BE NORMAL WEIGHT (25 kg/m3), WELL MADE AND EXECUTED IN ACCORDANCE WITH THE PROJECT SPECIFICATIONS. - REINFORCED CONCRETE SHOULD HAVE A MINIMUM 28 DAYS DESIGN COMPRESSIVE STRENGTH ON STANDARD 15 x 30cm CYLINDER 25MPa OTHERWISE AS INDICATED ON THE DRAWINGS. - BLINDING CONCRETE SHOULD HAVE A MINIMUM 28 DAYS DESIGN COMPRESSIVE STRENGTH ON STANDARD 15 x 30cm CYLINDER: F'c =11 Mpa. - FOR CYCLOPEAN CONCRETE, THE MINIMUM CEMENT CONTENT SHALL BE 150 kg/m.concrete FOR SCREENING SHALL HAVE A MINIMUM CEMENT CONTENT of 2 kg/m. - FOR STRUCTURAL CONCRETE, THE MINIMUM CEMENT CONTENT SHALL BE 350 kg/m. - ALL CEMENT FOR CONCRETE OTHER THAN SEWAGE STRUCTURES SHALL BE ORDINARY PORTLAND CEMENT TYPE I (ASTM). - ALL CEMENT FOR SEWAGE STRUCTURES SHALL BE SULFATE RESISTING CEMENT TYPE V (ASTM). 11- UTILITIES: - THE CONTRACTOR MUST IMMEDIATELY ON BEING AWARDED THE PROJECT, CONTACT ALL AUTHORITIES AND DEPARTMENTS CONCERNED IN LOCATING AND DIVERTING TEMPORARY OR PERMANENT EXISTING UTILITIES THAT WOULD INTERFERE WITH HIS WORK. THE CONTRACTOR MUST INSURE NO DAMAGE OF ANY NATURE OCCUR TO DISRUPT THEM. ANY DAMAGE DUE TO ANY REASON IS THE RESPONSIBILITY OF THE CONTRACTOR AND HE MUST IMMEDIATELY CORRECT AND BEAR ALL COSTS. THE CONCERNED UTILITIES ARE NAMELY: OVERHEAD OR UNDERGROUND ELECTRIC CABLES AND POLES, STREET LIGHTING CABLES AND POLES, MANHOLES AND PIPES, STORM WATER DRAINAGE INLETS, MANHOLES AND PIPES, TELEPHONE DUCTS, JUNCTION BOXES AND WATER SUPPLY PIPES AND VALVES. 12- ALL GRAVITY PIPES SHALL BE AS FOLLOWS: A. PIPES WITH INTERNAL DIAMETERS BETWEEN Ø150 MM TO Ø3MM INCLUSIVE, SHALL BE OF UPVC AS SPECIFIED. B. SEWER PIPES WITH INTERNAL DIAMETERS BETWEEN Ø4 MM TO Ø6MM INCLUSIVE, SHALL BE OF RC AS SPECIFIED. C. STORM PIPES WITH INTERNAL DIAMETERS BETWEEN Ø4 MM TO Ø6MM INCLUSIVE, SHALL BE OF GRP AS SPECIFIED. D. PIPES WITH INTERNAL DIAMETERS GREATER THAN 6MM SHALL BE GRP AS SPECIFIED AND TO BE APPROVED BY ENGINEER. 13- TOPOGRAPHY: - THE CONTRACTOR MUST SUBMIT A VERY DETAILED SURVEY FOR THE PROJECT AREA ESPECIALLY FOR EVERY LOCATION OF BRIDGES AND RETAINING WALLS TO DEFINE THE EXACT EXTENT AND HEIGHT. 14- THE GROUND ELEVATIONS SHOWN ON THE DRAWINGS REFLECT THE EXISTING SITUATION AT THE TIME THE SURVEYING WAS DONE. THE CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFYING THIS DATA, AND NO ADDITIONAL COST WILL BE CONSIDERED IN RESPECT TO ANY INACCURACY OR OMISSION. SOME OF THE STREET LEVELS WILL BE SUBJECT TO MODIFICATIONS DEPENDING ON FINAL GRADING AND ASPHALTING OF STREETS WHICH IS BEING CARRIED OUT BY THE LOCAL AUTHORITIES, HENCE THE CONTRACTOR SHALL MODIFY MANHOLE COVER TO MATCH THE FINAL PAVED SURFACES WHICH SHALL BE INDICATED AT THE TIME OF THE EXECUTION OF THE WORKS, ALL AS DIRECTED AND APPROVED BY THE ENGINEER. 15- IN PRINCIPLE, GRAVITY PIPES ARE LOCATED AS SHOWN ON THE DETAILED DRAWINGS FOR LOCATION OF UTILITIES UNDER ROADS. FINAL LOCATIONS SHALL BE MODIFIED TO SUIT OTHER EXISTING UTILITIES IN THE STREET ALL AS DIRECTED BY THE ENGINEER 16- WHERE THE STREET LIMITS ARE NOT DEFINED ON THE SITE BY ACTUAL BUILDINGS OR REFERENCE POINTS, THE CONTRACTOR SHALL, BEFORE INSTALLING ANY PIPE OR STRUCTURE, CONSULT WITH THE MUNICIPALITY TO ESTABLISH THE NECESSARY REFERENCE POINTS. 17- ALL PIPE DIAMETERS AND OTHER DIMENSIONS ARE SHOWN IN MILLIMETERS UNLESS OTHERWISE INDICATED AND ALL ELEVATIONS ARE IN METERS. 18- WHENEVER THE DRAWINGS SHOW A FUTURE LINE CONNECTING TO A MANHOLE THE CONTRACTOR SHALL PROVIDE AND INSTALL A STUB WITH A REMOVABLE PLUG. THE STUB SHALL HAVE THE DIAMETER AND INVERT OF THE FUTURE LINE,ALL AS DIRECTED AND APPROVED BY THE ENGINEER. 19- FOR PRECAST REINFORCED CONCRETE MANHOLE BASES, OPENING FOR PIPES SHALL BE CAST IN THE BASE AT THE REQUIRED LOCATION DURING ITS MANUFACTURE. FIELD CUT OPENING WILL NOT BE PERMITTED. 20- MANHOLE STEPS AND HANDBAR SHALL BE GALVANIZED STEEL WITH 2 GRAMS OF ZINC PER SQUARE METER AND COVERED WITH TWO LAYERS OF POLYETHYLENE (PE) OR POLYPROPYLENE. 21- THE CONTRACTOR SHALL PROVIDE OPENING IN THE INSPECTION CHAMBER TO ACCOMMODATE FUTURE HOUSE CONNECTION AS APPROVED BY THE ENIGNEER. THIS OPENING WILL BE FITTED WITH A REMOVABLE PLUG.LOCATION OF INSPECTION CHAMBERS IS SUBJECT TO SUIT LOCAL CONDITIONS AND AS APPROVED BY THE ENGINEER. 22- Y-SERVICE CONNECTIONS TO BE USED ONLY IF APPROVED BY THE ENGINEER. 23- THE MINIMUM VERTICAL CLEARANCE BETWEEN STORM & SEWER PIPES AT CROSSINGS SHALL BE 30cm, OTHERWISE, CONCRETE ENCASEMENT SHALL BE IMPLEMENTED FOR THE STORM PIPE. 24- CONSTRUCTION METHOD: - THE CONTRACTOR HAS TO PREPARE CONSTRUCTION METHOD AND PROGRAM OF WORK TAKING INTO CONSIDERATION SAFETY AND NON-STOP TRAFFIC ALONG THE ROAD. - NO WORK WILL BE ALLOWED PRIOR TO PLACING ALL THE REQUIRED TEMPORARY AND SAFETY SIGNS, TRAFFIC LIGHTS,FLAGS ETC WHEER AND WHENEVER REQUIRED. N.B.: ALL DRAWINGS A2 HAVE THE RIGHT AS INDICATED IN THE DRAWINGS. N.B.: THE DRAWINGS AND SPECIFICATIONS ARE COMPLEMENTARY AND THE CONTRACTOR SHALL READ THESE DRAWINGS IN CONJUNCTION WITH THE SPECIFICATIONS. NETWORK LABELS LABELS: LINE X : Pipe Label Ø : Pipe Diameter (mm) L : Pipe Length (m) S : Pipe Slope (%) UP.IL= Upstream invert level of pipe DN.I.L= Downstream invert level of pipe MH-X : Label G.L : ground level B.L : Bottom Level H : Depth to invert of pipe TOPOGAPHY Existing Sewer/Storm Line Existing Survey Point (Z: 22.30m) MRAYJE ION DRAWN BY: DESIGNED BY: CHECKED BY: APPROVED BY: PROJECT MANAGER : A.S JOB NUMBER : L01702 DATE GENERAL & --- L1702D-GN-

3 ﺷ ﺎﺭﻉ ﺃﺑ ﻲ ﻁﺎﻟ ﺏ ﻣﻧﻁﻘ ﺔ ﺍﻟﻣﺭﻳﺟ ﺔ Existing MH. (Ø6) G.L: I.L: LINE M-4 Ø2 LIN E Ø2 M-15 Ø4 LINE M LIN E Ø2 M-2 1 Rev. LINE M Ø4 Drawn Chkd. Appd. Ø3 LINE M Ø4 ﺍﺗﺣ ﺎﺩ ﺑﻠ ﺩﻳﺎﺕ ﺍﻟﺿ ﺎﺣﻳﺔ ﺍﻟﺟﻧﻭﺑﻳ ﺔ Revision Details Proposed Sewer Pipe Date A.S CHECKED BY: A.S APPROVED BY: MRAYJE ION H.I DESIGNED BY: 1/50 L01702 L1702D-WW-GNL-01 DATE JOB NUMBER : R.I A.S DRAWN BY: PROJECT MANAGER : SEWER LINES GENERAL LAYOUT LINE M Ø3 LINE M

4 C HEMIN C HEMIN T.L:33.34 I.L:30.79 D=6 T.L:33.17 I.L:30.77 D=9 Storm 44 wall P T.L:33.34 I.L:30.79 D=6 T.L:33.17 I.L:30.77 D=9 Storm Existing MH. G.L = m B.L = m H = 2.55 m power generator Ø4mm L = 17 m S = % UP.IL= m DN.IL= m MH-1 G.L = m B.L = m H = 1.91 m Ø4mm L = 22 m S = % UP.IL= m DN.IL= m MH-2 G.L = m B.L = m H = 1.91 m Ø4mm L = 15 m S = % UP.IL= m DN.IL= m MH G.L = m B.L = m H = 1.93 m Ø4mm L = m S = % UP.IL= m DN.IL= m -4 Ø2mm L = 17 m S = 1. % UP.IL= m DN.IL= m -4 Ø2mm L 159 = 21 m S = 1. % UP.IL= m DN.IL= m MH-4 G.L = m B.L = m H = 1.91 m Ø4mm L = 14 m S = % UP.IL= m DN.IL= m MH-1 G.L = m B.L = m H = 1.71 m MH-2 G.L = m B.L = m H = 1.70 m MH-5 G.L = m B.L = m H = 1.91 m Ø4mm L = 22 m S = % UP.IL= 33. m DN.IL= m MH-6 G.L = m B.L = 33. m H = 1.91 m Ø4mm L = 17 m S = 1. % UP.IL= m DN.IL= 33. m MH-7 G.L = m B.L = m H = 1.92 m Ø4mm L = 16 m S = 1. % UP.IL= m DN.IL= m MH-8 G.L = m B.L = m H = 1.90 m Ø4mm L = 16 m S = 1. % UP.IL= m DN.IL= m MH-9 G.L = m B.L = m H = 1.92 m Ø4mm L = m S = 1. % UP.IL= m DN.IL= m MH-10 G.L = m B.L = m H = 1.91 m Ø4mm L = 17 m S = 1. % UP.IL= m DN.IL= m 2386 MH-4 G.L = m 2384 B.L = m H = 1.70 m CHEMIN Ø2mm L = 19 m S = 1.84 % UP.IL= m DN.IL= m MH-3 G.L = m B.L = m H = 1.70 m -4 Ø2mm L = 26 m S = 2.12 % UP.IL= m DN.IL= 33.40m Pipe material shall be upvc for pipes smaller than or equal to 3 mm -Pipe material shall be RC for pipes equal to 4 mm as specified -Top of manhole cover shall match with finished grade -For manholes dimensions, refer to the corresponding details -All dimensions are in millimeters unless otherwise noted LABEL: LINE X : Pipe Label Ø : Pipe Diameter (mm) L : Pipe Length (m) S : Pipe Slope (%) UP.IL= Upstream invert level of pipe DN.I.L= Downstream invert level of pipe MH-X : Label G.L : ground level B.L : Bottom Level H : Depth KEY PLAN PL ش ارع ا ب ي طال ب PL-02 PL-03 MRAYJE ION SEWER LINES PLANS (1 OF 3) L1702D-WW-PL-01 1/5

5 1% 1% C HEMIN C HEMIN T.L:33.34 I.L:30.79 D=6 T.L:33.17 I.L:30.77 D=9 Storm 44 wall Ø4mm L = 22 m S = 1. % UP.IL= m DN.IL= m Ø3mm L = 25 m S = 0.88 % UP.IL= m DN.IL= m Ø2mm L = 20 m 3061 S = 0.50 % UP.IL= m DN.IL= m Ø3mm L = 25 m S = 0.88 % UP.IL= m DN.IL= m B.L = m Ø3mm L = 18 m S = 0.88 % UP.IL= m DN.IL= m MH-10 G.L = m B.L = m H = 1.91 m Ø4mm L = 17 m S = 1. % UP.IL= m DN.IL= m MH-11 G.L = m B.L = m H = 1.92 m MH-12 G.L = m B.L = m H = 1.91 m Ø4mm L = 24 m S = 1.40 % UP.IL= m DN.IL= m MH-13 G.L = m B.L = m H = 1.93 m Ø4mm L = 21 m S = 1. % UP.IL= m DN.IL= m MH-14 G.L = m B.L = m H = 2.13 m MH-15 G.L = m B.L = m H = 2.34 m MH-16 G.L = m B.L = m H = 2.23 m Ø4mm L = 19 m S = 1. % UP.IL= m DN.IL= m -15 Ø2mm L = 20 m S = 0.50 % UP.IL= m DN.IL= m MH-1 G.L = m B.L = m H = 2.41 m MH-2 G.L = m H = 2.22 m MH-17 G.L = m B.L = m H = 2.14 m MH-18 G.L = m B.L = m H = 2.06 m Ø3mm L = 24 m S = 1. % UP.IL= 35.72m DN.IL= m MH-19 G.L = m B.L = m H = 1.94 m Ø3mm L = 15 m S = 1. % UP.IL= m DN.IL= m Ø2mm L = 21 m S = 0.50 % UP.IL= m DN.IL= m MH-3 G.L = m B.L = m H = 1.94 m Ø2mm L = 28 m S = 0.50 % UP.IL= m DN.IL= m Ø2mm L = 29 m S = 1.66 % UP.IL= m DN.IL= 35.43m Pipe material shall be upvc for pipes smaller than or equal to 3 mm -Pipe material shall be RC for pipes equal to 4 mm as specified -Top of manhole cover shall match with finished grade -For manholes dimensions, refer to the corresponding details -All dimensions are in millimeters unless otherwise noted LABEL: LINE X : Pipe Label Ø : Pipe Diameter (mm) L : Pipe Length (m) S : Pipe Slope (%) UP.IL= Upstream invert level of pipe DN.I.L= Downstream invert level of pipe MH-X : Label G.L : ground level B.L : Bottom Level H : Depth KEY PLAN PL ش ارع ا ب ي طال ب PL-02 PL-03 MRAYJE ION SEWER LINES PLANS (2 OF 3) L1702D-WW-PL-02 1/5

6 0.50% % % 0.50% % % % C HEMIN C HEMIN T.L:33.34 I.L:30.79 D=6 T.L:33.17 I.L:30.77 D=9 Storm 44 wall wall Line 152 M-21 Ø2mm L = 13 m S = 0.50 % UP.IL= m DN.IL= m B.L 2.5% = m MH-2 Ø3mm G.L = m L = 18 m B.L = m S = 1.44 % 2771 H = 2.09 m UP.IL= m DN.IL= m Ø3mm L = 14 m S = 1.36 % UP.IL= m DN.IL= m 2564 Gr. Ø3mm L = 13 m S = 2.15 % 2560 UP.IL= m DN.IL= m MH-19 G.L = m B.L = m H = 1.94 m Ø3mm L = 15 m S = 1. % UP.IL= m DN.IL= m MH-20 G.L = m B.L = m H = 1.87 m Ø3mm L = 12 m S = 1. % UP.IL= m DN.IL= m -21 Ø2mm L = 7 m S = 0.50 % UP.IL= m DN.IL= m MH-21 G.L = m B.L = m H = 1.80 m MH-1 G.L = m H = 1.73 m MH-22 G.L = m B.L = m H = 1.80 m MH-23 G.L = m B.L = m H = 1.80 m Ø3mm L = 23 m S = 1.70 % UP.IL= 36.64m DN.IL= m Ø3mm L = 14 m S = 0.86 % UP.IL= m DN.IL= m MH-3 G.L = m B.L = m H = 1.88 m MH-24 G.L = m B.L = m H = 1.80 m MH-25 G.L = m B.L = m H = 1.80 m MH-26 G.L = m B.L = m H = 1.80 m Ø3mm L = 18 m S = 2.89 % UP.IL= 37.75m DN.IL= m MH-27 G.L = m B.L = m H = 1.80 m Ø3mm L = 18 m S = 3.17 % UP.IL= m DN.IL= m MH-28 G.L = m B.L = m H = 1.80 m Ø3mm L = 18 m S = 1.83 % UP.IL= m DN.IL= m MH-29 G.L = m B.L = m H = 1.80 m Ø2mm L = 15 m S = 0.50 % UP.IL= m DN.IL= m -21 Ø2mm L = 15 m S = 0.50 % UP.IL= m DN.IL= m MH-4 G.L = 38. m B.L = m H = 1.66 m Pipe material shall be upvc for pipes smaller than or equal to 3 mm -Pipe material shall be RC for pipes equal to 4 mm as specified -Top of manhole cover shall match with finished grade -For manholes dimensions, refer to the corresponding details -All dimensions are in millimeters unless otherwise noted LABEL: LINE X : Pipe Label Ø : Pipe Diameter (mm) L : Pipe Length (m) S : Pipe Slope (%) UP.IL= Upstream invert level of pipe DN.I.L= Downstream invert level of pipe MH-X : Label G.L : ground level B.L : Bottom Level H : Depth KEY PLAN PL ش ارع ا ب ي طال ب PL-02 PL-03 MRAYJE ION SEWER LINES PLANS (3 OF 3) L1702D-WW-PL-03 1/5

7 CONNECT TO EXITING MANHOLE (Ø6) MH MH MH Ø2 MH4 LINE M MH MH MH MH MH MH MH MH MH MH MH MH Ø2 MH15 LINE M MH16 1. ALL DIMENSIONS ARE IN METERS, UNLESS OTHERWISE INDICATED. 2. THE ACCURACY OF DIMENSIONS D FROM THE DRAWINGS IS NOT GUARANTEED. OBTAIN FROM THE ENGINEER ANY DIMENSIONS REQUIRED, BUT NOT GIVEN IN FIGURES ON THE DRAWINGS NOR CALCULABLE FROM FIGURES ON THE DRAWINGS. 3. ANY CONTRADICTION WITH OR DEVIATION FROM SUBMITTED DRAWINGS MUST BE PRESENTED FOR CONSENT BY THE ENGINEER. 4. THIS DRAWINGS SHALL NOT BE AMENDED, MODIFIED, OR ALTERED IN ANY WAY OR FORM WITHOUT PRIOR PERMISSION OF THE SUBURB UNION OF MUNICIPALITIES. 5. THE CONTRACTOR SHALL COORDINATE WITH THE MUNICIPALITY AND THE LOCAL AUTHORITIES IN ORDER TO IDENTIFY THE DISCHARGE POINTS OF THE SEWAGE NETWORKS ON THE EXISTING RELATED NETWORKS WITH ALL THE NEEDED DATA (LEVELS, DIAMETERS...). MRAYJE ION DRAWN BY: DESIGNED BY: CHECKED BY: APPROVED BY: PROJECT MANAGER : A.S JOB NUMBER : L01702 DATE SEWER LINES PROFILES (1 OF 3) H:1/10 - V:1/1 L1702D-WW-PR-01

8 MH MH MH MH MH MH21 LINE M Ø2 MH MH MH MH MH MH MH MH MH29 1. ALL DIMENSIONS ARE IN METERS, UNLESS OTHERWISE INDICATED. 2. THE ACCURACY OF DIMENSIONS D FROM THE DRAWINGS IS NOT GUARANTEED. OBTAIN FROM THE ENGINEER ANY DIMENSIONS REQUIRED, BUT NOT GIVEN IN FIGURES ON THE DRAWINGS NOR CALCULABLE FROM FIGURES ON THE DRAWINGS. 3. ANY CONTRADICTION WITH OR DEVIATION FROM SUBMITTED DRAWINGS MUST BE PRESENTED FOR CONSENT BY THE ENGINEER. 4. THIS DRAWINGS SHALL NOT BE AMENDED, MODIFIED, OR ALTERED IN ANY WAY OR FORM WITHOUT PRIOR PERMISSION OF THE SUBURB UNION OF MUNICIPALITIES. 5. THE CONTRACTOR SHALL COORDINATE WITH THE MUNICIPALITY AND THE LOCAL AUTHORITIES IN ORDER TO IDENTIFY THE DISCHARGE POINTS OF THE SEWAGE NETWORKS ON THE EXISTING RELATED NETWORKS WITH ALL THE NEEDED DATA (LEVELS, DIAMETERS...). MRAYJE ION DRAWN BY: DESIGNED BY: CHECKED BY: APPROVED BY: PROJECT MANAGER : A.S JOB NUMBER : L01702 DATE SEWER LINES PROFILES (2 OF 3) H:1/10 - V:1/1 L1702D-WW-PR-02

9 MH21 (LINE M) MH MH MH MH MH15 (LINE M) MH MH MH MH MH MH4 (LINE M) MH MH MH MH4 1. ALL DIMENSIONS ARE IN METERS, UNLESS OTHERWISE INDICATED. 2. THE ACCURACY OF DIMENSIONS D FROM THE DRAWINGS IS NOT GUARANTEED. OBTAIN FROM THE ENGINEER ANY DIMENSIONS REQUIRED, BUT NOT GIVEN IN FIGURES ON THE DRAWINGS NOR CALCULABLE FROM FIGURES ON THE DRAWINGS. 3. ANY CONTRADICTION WITH OR DEVIATION FROM SUBMITTED DRAWINGS MUST BE PRESENTED FOR CONSENT BY THE ENGINEER. 4. THIS DRAWINGS SHALL NOT BE AMENDED, MODIFIED, OR ALTERED IN ANY WAY OR FORM WITHOUT PRIOR PERMISSION OF THE SUBURB UNION OF MUNICIPALITIES. 5. THE CONTRACTOR SHALL COORDINATE WITH THE MUNICIPALITY AND THE LOCAL AUTHORITIES IN ORDER TO IDENTIFY THE DISCHARGE POINTS OF THE SEWAGE NETWORKS ON THE EXISTING RELATED NETWORKS WITH ALL THE NEEDED DATA (LEVELS, DIAMETERS...). MRAYJE ION DRAWN BY: DESIGNED BY: CHECKED BY: APPROVED BY: PROJECT MANAGER : A.S JOB NUMBER : L01702 DATE SEWER LINES PROFILES (3 OF 3) H:1/10 - V:1/1 L1702D-WW-PR-03

10 SERVICE PIPELINES AND HOUSE CONNECTIONS INSPECTION CHAMBER INSPECTION CHAMBER : 1. ALL DIMENSIONS ARE IN MILLIMETERS, PIPE DIAMETERS ARE IN MILLIMETERS UNLESS OTHERWISE INDICATED. 2. THE CHOICE OF TYPE OF CONNECTION BETWEEN THE MAIN SEWER PIPELINE (SADDLE, "Y" OR SPECIAL GRP CONNECTION) WILL BE DECIDED ON SITE BY THE ENGINEER. MRAYJE ION GEOMETRIC PAVEMENT DRAINAGE STRUCTURAL P. MANAGER M.B A.S H.H A.SH A.S DRAWN : A.HJ. CHECKED : M.B. APPROVED : A.S. INSPECTION CHAMBER HOUSE CONNECTION DETAILS DATE L1702D-WW-DE-10 AS SHOWN

11 DETAIL OF CONNECTION OF A SERVICE PIPE OR BRANCH PIPE TO A MAIN SEWER PIPELINE CASE "1" CASE "2" : 1. ALL DIMENSIONS ARE IN MILLIMETERS UNLESS OTHERWISE INDICATED. MRAYJE ION GEOMETRIC PAVEMENT DRAINAGE STRUCTURAL P. MANAGER M.B A.S H.H A.SH A.S DRAWN : A.HJ. CHECKED : M.B. APPROVED : A.S. HOUSE CONNECTION DETAILS (1 OF 3) DATE L1702D-WW-DE-11 AS SHOWN

12 HOUSE BRANCH TO MAIN SEWER PIPELINE : 1. ALL DIMENSIONS ARE IN MILLIMETERS UNLESS OTHERWISE INDICATED. 2. FOR INSPECTION CHAMBER DETAIL REFER TO DRAWING N L1701D-WW-DT THE CHOICE OF TYPE OF CONNECTION BETWEEN THE MAIN SEWER PIPELINE AND THE SERVICE PIPELINE (SADDLE, "Y" OR SPECIAL CONNECTION) WILL BE DECIDED ON SITE BY THE ENGINEER. 4. THE UPPER END OF THE HOUSE CONNECTION SHALL BE SEALED BY INSTALLING A CAP AND SEALING THE CAP WITH 23mm THICK MORTAR AROUND CIRCUMFERENCE OF THE CAP. 5. PROVISION FOR FUTURE CONNECTIONS SHALL BE CONSTRUCTED WHERE DIRECTED BY THE ENGINEER. 6. 1/16 (22 1/2 ) OR 1/8 (45 ) BENDS SHALL BE USED TO REMODEL OR CONSTRUCT ANY SEWER ON A CURVE OR AT OR AT ANY CHANGE IN ALIGNM WHERE PHYSICAL OR GEOMETRIC LIMITATIONS PRECLUDE THE USE OF 1/16 OR 1/8 BENDS, THE CONTRACTOR SHALL SUBMIT TO THE ENGINEER FOR FOR APPROVAL HIS PROPOSED METHOD OF REMODELING OR CONSTRUCTION. 7. IN CASE OF CONCRETE MAIN SEWER PIPELINE, ALL THE CONNECTIONS WITH THIS LINE SHOULD BE DONE IN THE MANHOLES LOCATIONS. NO DRILLING OF CONCRETE PIPE IS ALLOWED AND ALL CONNECTIONS SHOULD BE DONE WITH THE MANHOLES ONLY. 8. ALL HOUSE CONNECTION SEWERS CONSTRUCTED ON A SLOPE EXCEEDING 15% SHOULD BE ANCHORED. 9. ALL HOUSE CONNECTION SEWERS TO BE CONSTRUCTED UNDER A PROPOSED CONDUIT SHALL BE ENCASED IN CONCRETE. 10. ALL SEWER PIPE WITH COVER (LESS THAN 6mm IN SIDEWALK OR SHOULDER & 9mm IN ROAD) SHALL BE CONCRETE ENCASED. MRAYJE ION GEOMETRIC PAVEMENT DRAINAGE STRUCTURAL P. MANAGER M.B A.S H.H A.SH A.S DRAWN : A.HJ. CHECKED : M.B. APPROVED : A.S. HOUSE CONNECTION DETAILS (2 OF 3) DATE L1702D-WW-DE-12 AS SHOWN

13 SERVICE CONNECTION FROM INSPECTION CHAMBER TO MANHOLE CONNECTION OF A SERVICE LINE TO A MAIN SEWER PIPELINE : 1. ALL DIMENSIONS ARE IN MILLIMETERS UNLESS OTHERWISE INDICATED. 2. FOR INSPECTION CHAMBER DETAIL REFER TO DRAWING N L1701D-WW-DT THE CHOICE OF TYPE OF CONNECTION BETWEEN THE MAIN SEWER PIPELINE AND THE SERVICE PIPELINE (SADDLE, "Y" OR SPECIAL CONNECTION) WILL BE DECIDED ON SITE BY THE ENGINEER. 4. THE UPPER END OF THE HOUSE CONNECTION SHALL BE SEALED BY INSTALLING A CAP AND SEALING THE CAP WITH 23mm THICK MORTAR AROUND CIRCUMFERENCE OF THE CAP. 5. PROVISION FOR FUTURE CONNECTIONS SHALL BE CONSTRUCTED WHERE DIRECTED BY THE ENGINEER. 6. 1/16 (22 1/2 ) OR 1/8 (45 ) BENDS SHALL BE USED TO REMODEL OR CONSTRUCT ANY SEWER ON A CURVE OR AT OR AT ANY CHANGE IN ALIGNM WHERE PHYSICAL OR GEOMETRIC LIMITATIONS PRECLUDE THE USE OF 1/16 OR 1/8 BENDS, THE CONTRACTOR SHALL SUBMIT TO THE ENGINEER FOR FOR APPROVAL HIS PROPOSED METHOD OF REMODELING OR CONSTRUCTION. 7. IN CASE OF CONCRETE MAIN SEWER PIPELINE, ALL THE CONNECTIONS WITH THIS LINE SHOULD BE DONE IN THE MANHOLES LOCATIONS. NO DRILLING OF CONCRETE PIPE IS ALLOWED AND ALL CONNECTIONS SHOULD BE DONE WITH THE MANHOLES ONLY. 8. ALL HOUSE CONNECTION SEWERS CONSTRUCTED ON A SLOPE EXCEEDING 15% SHOULD BE ANCHORED. 9. ALL HOUSE CONNECTION SEWERS TO BE CONSTRUCTED UNDER A PROPOSED CONDUIT SHALL BE ENCASED IN CONCRETE. 10. ALL SEWER PIPE WITH COVER (LESS THAN 6mm IN SIDEWALK OR SHOULDER & 9mm IN ROAD) SHALL BE CONCRETE ENCASED. MRAYJE ION GEOMETRIC PAVEMENT DRAINAGE STRUCTURAL P. MANAGER M.B A.S H.H A.SH A.S DRAWN : A.HJ. CHECKED : M.B. APPROVED : A.S. HOUSE CONNECTION DETAILS (3 OF 3) DATE L1702D-WW-DE-13 AS SHOWN

14 ﺷ ﺎﺭﻉ ﺃﺑ ﻲ ﻁﺎﻟ ﺏ ﻣﻧﻁﻘ ﺔ ﺍﻟﻣﺭﻳﺟ ﺔ Existing MH. (Ø9) G.L: I.L: Ø3 0 0 Rev. Ø6 Proposed Storm Pipe Ø5 Drawn Chkd. Appd. ﺍﺗﺣ ﺎﺩ ﺑﻠ ﺩﻳﺎﺕ ﺍﻟﺿ ﺎﺣﻳﺔ ﺍﻟﺟﻧﻭﺑﻳ ﺔ Revision Details Proposed Gully Pipe Date A.S CHECKED BY: A.S APPROVED BY: MRAYJE ION H.I DESIGNED BY: L /50 L1702D-SW-GNL-01 DATE JOB NUMBER : R.I A.S DRAWN BY: PROJECT MANAGER : STORM LINES GENERAL LAYOUT Ø6 Ø6 Ø4 Ø3

15 CHEMIN CHEMIN wall power generator Storm D=9 I.L:30.77 T.L:33.17 D=6 I.L:30.79 T.L:33.34 Gr. 0.50% % % % % % 0.50% % 2.27% 2.27% PL-01 PL-02 PL-03 ب لاط ي با عرا ش Ø2 Ø2 Ø2 Ø4 Ø4 Ø4 Ø3 Ø3 LINE M LINE M LINE M LINE M LINE M LINE M-4 LINE M-15 LINE M-21 ة جيرملا ة قطنم Existing MH. (Ø6) G.L: I.L: Y=-342 Y=-341 Y=-340 Y=-339 Y=-338 Y=-337 Y=-336 X= X= X= X= X= X= X= PROJECT MANAGER : A.S JOB NUMBER : L01702 DATE DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: ة يبونجلا ةيحا ضلا تايد لب دا حتا AS SHOWN MRAYJE ION SEWER LINES L1702D-WW-KPL-01 GENERAL KEY PLAN Proposed Sewer Pipe

16 CHEMIN CHEMIN wall power generator Storm D=9 I.L:30.77 T.L:33.17 D=6 I.L:30.79 T.L:33.34 Gr. 0.50% % % % % % 0.50% % 2.27% 2.27% PL-01 PL-02 PL-03 ب لاط ي با عرا ش ة جيرملا ة قطنم Existing MH. (Ø9) G.L: I.L: Y=-342 Y=-341 Y=-340 Y=-339 Y=-338 Y=-337 Y=-336 X= X= X= X= X= X= X= Ø6 Ø6 Ø6 Ø5 Ø4 Ø3 Ø3 PROJECT MANAGER : A.S JOB NUMBER : L01702 DATE DESIGNED BY: DRAWN BY: CHECKED BY: APPROVED BY: ة يبونجلا ةيحا ضلا تايد لب دا حتا AS SHOWN MRAYJE ION STORM LINES L1702D-SW-KPL-01 GENERAL KEY PLAN Proposed Storm Pipe Proposed Gully Pipe

17 C HEMIN C HEMIN T.L:33.34 I.L:30.79 D=6 T.L:33.17 I.L:30.77 D=9 Storm 44 wall P T.L:33.34 I.L:30.79 D=6 G-76 G.L = m B.L = m PG-76 L = 9.90 m S= 2.30 % UP.IL = m DN.IL = m T.L:33.17 I.L:30.77 D=9 Storm G-75 G.L = m B.L = m power generator PG-75 L = 6.50 m UP.IL = m DN.IL = m 2418 P-26 Ø6 mm L = m S = 1.30 % UP.IL= m DN.IL = m P-25 Ø6 mm L = m S = 1.30 % UP.IL= m DN.IL = m P-28 Ø6 mm L = m S = 1. % UP.IL= m DN.IL = m P-27 Ø6 mm L = m S = 1.30 % UP.IL= m DN.IL = m PG-70 L = 2.90 m S= 0.90 % UP.IL = m DN.IL = m PG-73 L = 4. m S= 0.80 % UP.IL = m DN.IL = m 2420 PG-67 L = 9.20 m S= 0.80 % UP.IL = m DN.IL = m PG-66 L = 3.80 m S= 0.80 % UP.IL = m DN.IL = m P-24 Ø6 mm L = m S = 1.20 % UP.IL= m DN.IL = m P G-70 G.L = m B.L = m G-63 G.L = m B.L = m G-61 G.L = 35. m B.L = m MH-26 G.L = m B.L = m H = 2. m PG-62 L = m S= 0.50 % UP.IL = m DN.IL = m PG-52 L = m S= 1.10 % UP.IL = m DN.IL = m MH-27 G.L = 34. m B.L = m H = 2.10 m G-73 G.L = 34. m B.L = m G-67 G.L = m B.L = m H = 1.58 m G-66 G.L = m B.L = m PG-61 L = 6.40 m S= 0.80 % UP.IL = m DN.IL = m G-53 G.L = m B.L = m MH-25 G.L = m B.L = m H = 2.06 m PG MH-24 G.L = m B.L = m H = 2.13 m G-62 G.L = m B.L = m PG-57 L = m UP.IL = m DN.IL = m P-22 Ø6 mm L = m S = 0.70 % UP.IL= m DN.IL = m G-57 G.L = m B.L = m H = 2.25 m L = 2.90 m S= 0.80 % UP.IL = m DN.IL = m B.L = m P-23 Ø6 mm L = m S = 1.30 % UP.IL= m DN.IL = m G-52 G.L = m B.L = m MH-28 G.L = m B.L = m PG-72 L = 7.50 m UP.IL = m DN.IL = m G-65 G.L = m PG-74 L = m UP.IL = m DN.IL = m G-74 G.L = m B.L = m G-71 G.L = m B.L = m PG L = 5.90 m PG-53 L = 2.80 m S= 0.80 % UP.IL = m DN.IL = m UP.IL = m DN.IL = m MH G-72 G.L = 34. m B.L = m PG-71 L = m UP.IL = m DN.IL = m G-64 G.L = m B.L = m G-58 G.L = m B.L = m G.L = m B.L = m H = 2. m G-60 G.L = m B.L = m PG-59 L = m UP.IL = m DN.IL = m G-59 G.L = m B.L = m MH-22 G.L = m B.L = m H = 2. m PG-50 PG-69 L = m UP.IL = m DN.IL = m PG-60 L = 7.10 m UP.IL = m DN.IL = m PG-56 L = m UP.IL = m DN.IL = m G-55 G.L = m B.L = m PG-54 L = 6.70 m UP.IL = m DN.IL = m PG-68 L = 5. m S= 2.20 % UP.IL = m DN.IL = m PG-64 L = m S= 1.70 % UP.IL = m DN.IL = m PG-58 L = m S= 1.70 % UP.IL = m DN.IL = m G-56 G.L = m B.L = m H = 1.63 m PG-55 L = m UP.IL = m DN.IL = m G-54 G.L = m B.L = m CHEMIN Pipe material shall be upvc for pipes smaller than or equal to 3 mm -Pipe material shall be GRP for pipes equal to or higher than 4 mm -Top of manhole cover shall match with finished grade -For manholes dimensions, refer to the corresponding details -All dimensions are in millimeters unless otherwise noted LABEL: LINE X : Pipe Label Ø : Pipe Diameter (mm) L : Pipe Length (m) S : Pipe Slope (%) UP.IL= Upstream invert level of pipe DN.I.L= Downstream invert level of pipe MH-X : Label G.L : ground level B.L : Bottom Level H : Depth KEY PLAN PL ش ارع ا ب ي طال ب PL-02 PL-03 MRAYJE ION STORM LINES PLANS (1 OF 3) L1702D-SW-PL-01 1/5

18 1% 1% C HEMIN C HEMIN T.L:33.34 I.L:30.79 D=6 T.L:33.17 I.L:30.77 D=9 Storm 44 wall P-10 Ø5 mm L = m S = 0.70 % UP.IL= m DN.IL = m DN.IL = m B.L = m H = 2.38 m G.L = m PG-52 L = m S= 1.10 % UP.IL = m DN.IL = m G.L = m B.L = m G-33 G.L = m B.L = m G-37 G.L = m B.L = m H = 1.58 m G-31 G.L = m B.L = 36. m G-52 G.L = m B.L = m P-21 Ø6 mm MH-21 L = m G.L = m S = 1. % B.L = m UP.IL= m H = 2. m DN.IL = m PG-51 L = 10. m UP.IL = m DN.IL = m PG-35 L = 5.50 m UP.IL = m DN.IL = m PG-31 L = 9.80 m S= 5.60 % UP.IL = m DN.IL = m G-51 G.L = m B.L = m P-20 Ø6 mm L = m S = 0.80 % UP.IL= m DN.IL = m G-46 G.L = m B.L = m PG-36 L = 5.50 m S= 0.50 % UP.IL = m DN.IL = m UP.IL = m DN.IL = m G-47 G.L = m B.L = m G-45 G.L = m B.L = m G-35 G.L = m B.L = m PG-25 L = 8.40 m PG-46 L = m S= 2.10 % UP.IL = m DN.IL = m PG-33 L = 6.70 m UP.IL = m DN.IL = m UP.IL = m DN.IL = m P-18 Ø6 mm L = m S = 1. % UP.IL= m DN.IL = m G-36 G.L = m B.L = m H = 1.62 m G-32 G.L = 37. m B.L = m H = 1.56 m PG-47 L = 2.90 m S= 0.80 % G-30 G.L = m B.L = m PG-26 L = m S= 0.50 % UP.IL = m DN.IL = m MH-19 G.L = m B.L = m H = 2. m PG-45 L = m S= % UP.IL = m DN.IL = m PG-32 L = 5.20 m S= 0.50 % UP.IL = m DN.IL = m G-24 G.L = m B.L = m PG-54 L = 6.70 m UP.IL = m PG-50 L = 5.90 m UP.IL = m DN.IL = m PG-30 L = 2.90 m S= 0.80 % PG-37 L = 3.10 m UP.IL = m S= 2.60 % P-11 Ø5 mm L = m S = 0.70 % UP.IL= m DN.IL = m UP.IL = m DN.IL = m G-28 G.L = m B.L = m G-26 G.L = m B.L = m H = 1.74 m DN.IL = m MH-20 G.L = m H = 2. m PG-48 L = 7.50 m S= 0.80 % UP.IL = m DN.IL = m PG-28 L = 2.80 m S= 2.10 % PG-44 L = 5.80 m UP.IL = m DN.IL = m G-49 G.L = m B.L = m G-48 G.L = m B.L = m UP.IL = m DN.IL = m G-54 G.L = m B.L = m G-50 G.L = m B.L = m PG-49 L = m S= 1.90 % UP.IL = m DN.IL = m MH-18 G.L = m B.L = m H = 2.26 m P-17 Ø6 mm L = m S = 0.60 % UP.IL= m DN.IL = m P-19 Ø6 mm L = m S = 1.80 % UP.IL= m DN.IL = m G-44 G.L = m B.L = m G-43 G.L = 37. m B.L = m PG-34 L = 9.40 m UP.IL = 36. m DN.IL = m MH-12 G.L = m B.L = m MH B.L = m H = 1.92 m PG-43 L = m S= 1.40 % UP.IL = m DN.IL = m MH-9 G-34 G.L = m B.L = m G.L = m B.L = m H = 1.90 m MH-11 G.L = m B.L = m H = 1.91 m G-29 G.L = m B.L = m PG-27 L = 7.50 m S= 1.10 % UP.IL = m DN.IL = m PG-38 L = m S= % UP.IL = m DN.IL = m P-16 Ø3 mm L = m S = 0.60 % UP.IL= m DN.IL = m MH-17 G.L = m B.L = m H = 2.20 m G-38 G.L = m B.L = m P-15 Ø3 mm L = m S = 0.60 % UP.IL= m DN.IL = m PG-29 L = 7.60 m UP.IL = m DN.IL = m P-9 Ø5 mm L = 20. m S = 0.50 % UP.IL= m DN.IL = m G-27 G.L = m B.L = m PG-22 L = 7.40 m S= 0.50 % UP.IL = m DN.IL = m MH-16 G.L = m B.L = m H = 2.05 m G-39 G.L = m B.L = m P-14 Ø3 mm L = m S = 0.60 % UP.IL= m DN.IL = m PG-39 L = 8.50 m S= 4.10 % UP.IL = m DN.IL = m P-13 Ø3 mm L = m S = 0.50 % UP.IL= m DN.IL = m G-41 G.L = m B.L = m MH-14 G.L = m B.L = m H = 1.70 m PG-41 L = 6.50 m S= 2.90 % UP.IL = m DN.IL = m P-12 Ø3 mm L = m S = 1.60 % UP.IL= m DN.IL = m MH-13 G.L = m B.L = m H = 1.70 m 156 G-42 G.L = m B.L = m PG-42 L = 6.60 m S= 2.90 % UP.IL = m DN.IL = m Pipe material shall be upvc for pipes smaller than or equal to 3 mm -Pipe material shall be GRP for pipes equal to or higher than 4 mm -Top of manhole cover shall match with finished grade -For manholes dimensions, refer to the corresponding details -All dimensions are in millimeters unless otherwise noted LABEL: LINE X : Pipe Label Ø : Pipe Diameter (mm) L : Pipe Length (m) S : Pipe Slope (%) UP.IL= Upstream invert level of pipe DN.I.L= Downstream invert level of pipe MH-X : Label G.L : ground level B.L : Bottom Level H : Depth KEY PLAN PL ش ارع ا ب ي طال ب PL-02 PL-03 MRAYJE ION STORM LINES PLANS (2 OF 3) L1702D-SW-PL-02 1/5

19 0.50% % % 0.50% % % % C HEMIN C HEMIN T.L:33.34 I.L:30.79 D=6 T.L:33.17 I.L:30.77 D=9 Storm 44 wall L = 8.40 m 3168 UP.IL = m DN.IL = m P-7 Ø4 mm L = m S = 0.80 % UP.IL= m DN.IL = m 2563 P-5 Ø4 mm L = 9. m S = 0.60 % UP.IL= m DN.IL = m P-4 Ø3 mm L = m S = 1.30 % UP.IL= 37. m DN.IL = m P-8 Ø5 mm L = m S = 0.50 % UP.IL= m DN.IL = m DN.IL = m Gr. 2.5% wall DN.IL = m PG-24 L = 3.70 m S= 0.50 % UP.IL = m DN.IL = m G-24 G.L = m B.L = m G-26 G.L = m B.L = m H = 1.74 m G-23 G.L = m B.L = m G-12 G.L = m B.L = m G-20 G.L = m B.L = m G-17 G.L = m B.L = m PG-9 L = 5.90 m UP.IL = m DN.IL = m PG-23 L = 5.60 m UP.IL = m DN.IL = m PG-20 L = 2.60 m S= 0.80 % UP.IL = m P-3 Ø3 mm L = m S = 1.90 % UP.IL= m DN.IL = 37. m P-2 Ø3 mm L = 28. m S = 3.90 % UP.IL= m DN.IL = m P-6 Ø4 mm L = m S = 0.50 % UP.IL= m DN.IL = m MH-5 G.L = m B.L = m H = 2.11 m G-10 G.L = m B.L = m PG-10 L = 2.60 m S= 1.10 % UP.IL = m DN.IL = m PG-12 L = 3.80 m S= 0.80 % G-6 G.L = m B.L = m PG-17 L = 2.90 m S= 0.90 % UP.IL = m DN.IL = m MH UP.IL = m DN.IL = m PG-6 L = 7. m S= 4.40 % UP.IL = m DN.IL = m MH-4 G.L = m B.L = 37. m H = 1.70 m G-9 G.L = m B.L = m G.L = m B.L = m H = 1.90 m MH-8 G.L = m B.L = m H = 1.90 m MH-3 G.L = m B.L = m H = 1.70 m PG-4 L = 2.90 m UP.IL = m DN.IL = m P-9 Ø5 mm L = 20. m S = 0.50 % UP.IL= m DN.IL = m G-22 G.L = m B.L = m H = 1.66 m MH-7 G.L = m B.L = m H = 2.05 m G-21 G.L = m B.L = m MH-6 G.L = m B.L = m H = 2.09 m G-19 G.L = m B.L = m G-18 G.L = m B.L = m G-16 G.L = m B.L = m PG-13 L = 7.90 m UP.IL = m DN.IL = m PG-18 L = m S= 2.70 % UP.IL = m DN.IL = m PG mm PG-16 L = 9.90 m UP.IL = 37. m DN.IL = m PG-14 L = m G-13 G.L = m UP.IL = m B.L = m DN.IL = m MH-2 G-11 G.L = m B.L = m L = 5.60 m UP.IL = m DN.IL = m G.L = m B.L = m H = 1.70 m PG-22 L = 7.40 m S= 0.50 % UP.IL = m DN.IL = m PG-19 L = 6.10 m UP.IL = m DN.IL = m G-15 G.L = m B.L = m G-14 G.L = m B.L = m PG-11 L = 8. m S= 0.50 % UP.IL = m DN.IL = m PG-21 L = m UP.IL = m DN.IL = m G-8 G.L = m B.L = m G-7 G.L = m B.L = m G-5 G.L = m B.L = m PG-15 L = 9.70 m UP.IL = m DN.IL = m PG-7 L = m S= 2.80 % UP.IL = m DN.IL = m PG-5 L = m S= 3.10 % UP.IL = m DN.IL = m PG-3 L = 8.70 m UP.IL = m DN.IL = m G-4 G.L = m B.L = m PG-1 L = 5.30 m S= 0.80 % UP.IL = m DN.IL = m P-1 Ø3 mm L = m S = 0.80 % UP.IL= m DN.IL = m G-1 G.L = m B.L = m MH-1 G.L = B.L = H = 1.70 m G-2 G.L = m B.L = m PG-2 L = 7.10 m UP.IL = m DN.IL = m G-3 G.L = m B.L = m Pipe material shall be upvc for pipes smaller than or equal to 3 mm -Pipe material shall be GRP for pipes equal to or higher than 4 mm -Top of manhole cover shall match with finished grade -For manholes dimensions, refer to the corresponding details -All dimensions are in millimeters unless otherwise noted LABEL: LINE X : Pipe Label Ø : Pipe Diameter (mm) L : Pipe Length (m) S : Pipe Slope (%) UP.IL= Upstream invert level of pipe DN.I.L= Downstream invert level of pipe MH-X : Label G.L : ground level B.L : Bottom Level H : Depth KEY PLAN PL ش ارع ا ب ي طال ب PL-02 PL-03 MRAYJE ION STORM LINES PLANS (3 OF 3) L1702D-SW-PL-03 1/5

20 PROFILE 1 (Part 1/2) Station Length Depth to Invert Invert Level Ground Level Slope 0.79% 3.86% 1.89% 1.25% 0.56% 0.54% 0.77% 0.51% 0.50% 0.69% 0.70% % Material UPVC GRP Section Size DATUM 32. I.L.= I.L.= I.L.= I.L.= I.L.= I.L.= I.L.= I.L.= I.L.= Ø3 I.L.= I.L.= I.L.= I.L.= I.L.= I.L.= I.L.= I.L.= I.L.= I.L.= I.L.= I.L.= I.L.= I.L.= I.L.= I.L.= I.L.= I.L.= I.L.= I.L.= I.L.= I.L.= I.L.= I.L.= MH-1 MH-2 MH-3 MH-4 MH-5 MH-6 MH-7 MH-8 MH-9 MH-10 MH-11 MH-12 MH MH-19 I.L.= I.L.= ALL DIMENSIONS ARE IN METERS, UNLESS OTHERWISE INDICATED. 2. THE ACCURACY OF DIMENSIONS D FROM THE DRAWINGS IS NOT GUARANTEED. OBTAIN FROM THE ENGINEER ANY DIMENSIONS REQUIRED, BUT NOT GIVEN IN FIGURES ON THE DRAWINGS NOR CALCULABLE FROM FIGURES ON THE DRAWINGS. 3. ANY CONTRADICTION WITH OR DEVIATION FROM SUBMITTED DRAWINGS MUST BE PRESENTED FOR CONSENT BY THE ENGINEER. 4. THIS DRAWINGS SHALL NOT BE AMENDED, MODIFIED, OR ALTERED IN ANY WAY OR FORM WITHOUT PRIOR PERMISSION OF THE SUBURB UNION OF MUNICIPALITIES. 5. THE CONTRACTOR SHALL COORDINATE WITH THE MUNICIPALITY AND THE LOCAL AUTHORITIES IN ORDER TO IDENTIFY THE DISCHARGE POINTS OF THE SEWAGE NETWORKS ON THE EXISTING RELATED NETWORKS WITH ALL THE NEEDED DATA (LEVELS, DIAMETERS...). MRAYJE ION DRAWN BY: DESIGNED BY: CHECKED BY: APPROVED BY: PROJECT MANAGER : A.S JOB NUMBER : L01702 DATE STORM LINES PROFILES (1 OF 3) H:1/10 - V:1/1 L1702D-SW-PR-01

21 PROFILE 1 (Part 2/2) Station Length Depth to Invert Invert Level Ground Level Slope 1.80% 0.84% 1.01% 0.71% 1.28% % % 1.05% Material GRP Section Size 6 DATUM 29. I.L.= I.L.= I.L.= I.L.= I.L.= I.L.= I.L.= I.L.= I.L.= I.L.= I.L.= I.L.= I.L.= I.L.= I.L.= I.L.= I.L.= I.L.= I.L.= I.L.= I.L.= MH-19 MH-20 MH-21 MH-22 MH-23 MH-24 MH-25 MH-26 MH-27 MH-28 O-1 I.L.= ALL DIMENSIONS ARE IN METERS, UNLESS OTHERWISE INDICATED. 2. THE ACCURACY OF DIMENSIONS D FROM THE DRAWINGS IS NOT GUARANTEED. OBTAIN FROM THE ENGINEER ANY DIMENSIONS REQUIRED, BUT NOT GIVEN IN FIGURES ON THE DRAWINGS NOR CALCULABLE FROM FIGURES ON THE DRAWINGS. 3. ANY CONTRADICTION WITH OR DEVIATION FROM SUBMITTED DRAWINGS MUST BE PRESENTED FOR CONSENT BY THE ENGINEER. 4. THIS DRAWINGS SHALL NOT BE AMENDED, MODIFIED, OR ALTERED IN ANY WAY OR FORM WITHOUT PRIOR PERMISSION OF THE SUBURB UNION OF MUNICIPALITIES. 5. THE CONTRACTOR SHALL COORDINATE WITH THE MUNICIPALITY AND THE LOCAL AUTHORITIES IN ORDER TO IDENTIFY THE DISCHARGE POINTS OF THE SEWAGE NETWORKS ON THE EXISTING RELATED NETWORKS WITH ALL THE NEEDED DATA (LEVELS, DIAMETERS...). MRAYJE ION DRAWN BY: DESIGNED BY: CHECKED BY: APPROVED BY: PROJECT MANAGER : A.S JOB NUMBER : L01702 DATE STORM LINES PROFILES (2 OF 3) H:1/10 - V:1/1 L1702D-SW-PR-02

22 PROFILE 2 Station Length Depth to Invert Invert Level Ground Level Slope 1.64% 0.55% 0.58% 0.59% 0.57% Material UPVC Section Size 3 DATUM 32. I.L.= I.L.= I.L.= I.L.= I.L.= I.L.= MH-13 MH-14 MH-15 MH-16 MH-17 MH-12 I.L.= Ø5 I.L.= Ø6 I.L.= ALL DIMENSIONS ARE IN METERS, UNLESS OTHERWISE INDICATED. 2. THE ACCURACY OF DIMENSIONS D FROM THE DRAWINGS IS NOT GUARANTEED. OBTAIN FROM THE ENGINEER ANY DIMENSIONS REQUIRED, BUT NOT GIVEN IN FIGURES ON THE DRAWINGS NOR CALCULABLE FROM FIGURES ON THE DRAWINGS. 3. ANY CONTRADICTION WITH OR DEVIATION FROM SUBMITTED DRAWINGS MUST BE PRESENTED FOR CONSENT BY THE ENGINEER. 4. THIS DRAWINGS SHALL NOT BE AMENDED, MODIFIED, OR ALTERED IN ANY WAY OR FORM WITHOUT PRIOR PERMISSION OF THE SUBURB UNION OF MUNICIPALITIES. 5. THE CONTRACTOR SHALL COORDINATE WITH THE MUNICIPALITY AND THE LOCAL AUTHORITIES IN ORDER TO IDENTIFY THE DISCHARGE POINTS OF THE SEWAGE NETWORKS ON THE EXISTING RELATED NETWORKS WITH ALL THE NEEDED DATA (LEVELS, DIAMETERS...). MRAYJE ION DRAWN BY: DESIGNED BY: CHECKED BY: APPROVED BY: PROJECT MANAGER : A.S JOB NUMBER : L01702 DATE STORM LINES PROFILES (3 OF 3) H:1/10 - V:1/1 L1702D-SW-PR-03

23 STORM WATER MANHOLE : 1-AN UP STAND MIN. HEIGHT 15cm IS TO BE EXECUTED WITH THE MANHOLE SLAB IN ORDER TO ENSURE A PROPER CONCRETE CONNECTION FOR THE MANHOLE WALLS. 2-REFER TO "GENERAL " DWG. 3-MANHOLES COVERS AND FRAMES TO BE RAISED SHALL BE PROPERLY REMOVED, AND RETURNED TO THE MUNICIPALITY IF DIRECTED BY THE ENGINEER. 4-BITUMINOUS SURFACES TO REACH MANHOLES COVERS EDGES AS SHOWN. HOWEVER, IF DIRECTED BY THE ENGINEER, ANTI ABRASION EPOXY MORTAR TO BE APPLIED ON TOP OF MANHOLES IF CONCRETE SURFACES ARE LEFT EXPOSED TO TRAFFIC. LEGEND: : CONSTRUCTION JOINT, JOINT INCLUDING HYDROSWELLING MASTIC PROPERTIES FOR HYDROSWELLING MASTIC Cured (7 days at 25 C, 10 mm thick) Elongation at break Approx. 625% DIN Tensile strength Approx. 2.2N/mm2 DIN Resistance to hydrostatic pressure Swelling capacity in contact with water Up to 150 meters of water column Swells to approx. 350% of its original dry volume Text DNC Test report KUL University MRAYJE ION GEOMETRIC PAVEMENT DRAINAGE STRUCTURAL P. MANAGER M.B A.S H.H A.SH A.S DRAWN : A.HJ. CHECKED : M.B. APPROVED : A.S. STORM WATER MANHOLE DETAILS DATE L1702D-SW-DE-02 AS SHOWN

24 TYPICAL TRENCHES AND PIPE BEDDING DETAILS FLEXIBLE JOINT DETAIL : 1-REFER TO SPECIFICATIONS FOR PIPE BEDDING REQUIREMENTS APPLICABLE TO EACH PIPE MATERIAL. 2-ALL DIMENSIONS ARE IN MILLIMETERS UNLESS OTHERWISE INDICATED. 3-THE GRANULAR AND SAND FILL IN PIPE TRENCHES MUST BE COMPACTED ACCORDING TO SPECIFICATIONS. 4-THE CONTRACTOR SHALL IDENTIFY ALL THE EXISTING UTILITIES AND MANHOLES WITH THEIR LOCATIONS AND LEVELS, IN ORDER TO AVOID DAMAGE TO EXISTING WORKS. 5-CONCRETE ENCASEMENT FOR ALL PIPES MATERIALS IF THE HEIGHT OF FILLING OVER THE PIPE FROM GROUND LEVEL TO TO CROWN OF PIPE LESS THAN 1.0M AND MORE THAN 4.0M. 6-MINIMUM THICKNESS T1 OF COMPACTED MATERIAL UNDER BARREL BOTTOM: T1 = 150 FOR D<3mm T1 = 2 FOR 3<D<8mm T1 = D/4 FOR D>8 7-HEAVY COMPACTING EQUIPMENT SHALL NOT BE USED WITHIN 3mm OF PIPE CROWN. 8-ALL PIPES BUILT INTO STRUCTURES SHALL HAVE A FLEXIBLE JOINT AS DETAILED IN THIS DWG. 9-BACKFILL MATERIAL COMPACTED IN LAYERS NOT EXCEEDING 15cm OF COMPACTED THICKNESS. 10-SELECTED BACKFILL SHALL BE MATERIAL COMPLYING WITH SPECIFICATION EITHER SELECTED FROM THE EXCAVATION OR IMPORTED AS NECESSARY. 11-REFER TO DWG. "GENERAL AND LEGEND". 12- FOR TRENCH WIDTH REFER TO L1702-SW-DE-04. LEGEND: G.EL. : GROUND ELEVATION CONT. : CONTINUOUS LAP 50db AT SPLICES db : DEFORMED BAR DIAMETER IN mm DIA. : OUTSIDE DIAMETER D, Ø : PIPE DIAMETER THE MINIMUM THICKNESS " T " FOR CONCRETE ENCASEMENT TO PIPES SHALL BE AS FOLLOWS: - T = 150 FOR D<6 - T = 250 FOR 7<D<10 - T = D/4 FOR D> 10 WHERE THE DEPTH OF COVER OVER THE PIPES REQUIRES THICKER ENCASEM THE CONTRACTOR SHALL ACT AS DIRECTED BY THE ENGINEER. MRAYJE ION GEOMETRIC PAVEMENT DRAINAGE STRUCTURAL P. MANAGER M.B A.S H.H A.SH A.S DRAWN : A.HJ. CHECKED : M.B. APPROVED : A.S. TYPICAL TRENCHES DETAILS FOR STORM WATER NETWORK DATE L1702D-SW-DE-01 AS SHOWN

25 ROAD GULLY COVERED MANHOLE GRATED MANHOLE CHAIN AND STEPS DETAILS N.B: 1- MANHOLE DETAILS ARE SHOWN FOR TYPICAL 90 AND STRAIGHT PIPES CONNECTIONS, WHERE DIFFERENT JUNCTIONS OR BENDS ARE ENCOUNTERED THE MANHOLE BASE AND BENCHING SHALL BE MODIFIED TO SUIT EACH CONDITION AS DIRECTED BY THE ENGINEER AT NO EXTRA COST. 2- AL REINFORCED CONCRETE SHALL BE CLASS "A" AND CONCRETE FOR BLINDING SHALL BE CLASS"C". 3- GALVANIZED WROUGHT IRON CHAIN SHALL BE USED WHERE STORM WATER DIAMETER IS GREATER THAN 6mm. 4- EXTERNAL SURFACES OF MANHOLES SHALL BE PROTECTED WITH 2 COATS OF RC250 OR MC FOR PIPES PROTRUDING FROM ANY CONCRETE STRUCTURES TWO FLEXIBLE COUPLING SHALL BE PROVIDED FROM EACH SIDE. 6- THE CONTRACTOR SHALL IDENTIFY ALL THE EXISTING UTILITIES AND MANHOLES WITH THEIR LOCATIONS AND LEVELS, IN ORDER TO AVOID DAMAGE TO EXISTING WORKS. 7-20mm WIDE EXPANSION JOINT WITH BITUMINOUS FELT PAPER FILLER SHALL BE PROVIDED IN CONCRETE ENCASEMENT FOR ALL PIPE MATERIAL. JOINTS SHALL BE AT ALL PIPE JOINTS IN THE VICINITY AND WITHIN 5mm OR 1D FROM MANHOLES AND AT MAXIMUM INTERVALS OF ENCASEMENT BUT ALWAYS AT PIPE JOINTS, 8- ALL PIPES SHALL BE LAID ON THE APPROPRIATE TYPE OF BEDDING AND SHALL RECEIVE SELECTED FILL COMPACTED TO AT LEAST 3mm ABOVE CROWN OF PIPE. : 1-THE CONTRACTOR SHALL CLEAN ALL THE EXISTING STORM WATER NETWORK AS DIRECTED BY THE ENGINEER ON SITE. 2-CONCRETE ENCASEMENT SHALL BE PROVIDED WHEER THE COVER DEPTH FROM F.G.L TO CROWN OF PIPES IS LESS THAN 1.0m 3-EXACT LOCATIONS OF ROAD GULLIES AND INTERCEPTORS TO BE VERIFIED AND LOCATED BY THE CONTRACTOR ACCORDING TO THE EXISTING SITE CONDITIONS. 4-THE FINAL LEVEL ON TOP OF MANHOLE SHOULD BE VERIFIED BY THE CONTRACTOR PRIOR TO EXECUTION OF MANHOLES. 5-MANHOLE COVERS TO BE ADJUSTED ON SITE ACCORDING TO THE NEW ROADWAY FINAL GRADE LEVEL. 6-AL REINFORCED CONCRETE SHALL BE CLASS "A" AND CONCRETE FOR BLINDING SHALL BE CLASS"C". MRAYJE ION GEOMETRIC PAVEMENT DRAINAGE STRUCTURAL P. MANAGER M.B A.S H.H A.SH A.S DRAWN : A.HJ. CHECKED : M.B. APPROVED : A.S. GULLY & GULLY MANHOLE DETAILS DATE L1702D-SW-DE-03 AS SHOWN

26 DUCTILE IRON MANHOLE COVER PIPE BEDDING REQUIREMENTS LAYING OF DIFFERENT TYPES OF PIPES MUST BE ACCORDING TO THE TABLE BELOW & FRAME DETAILS UNLESS OTHERWISE INSTRUCTED BY THE ENGINEER PIPE DIAMETER (mm) TRENCH WIDTH, mm (W) H<2m 2<H<3m 3<H<4m 4<H<5m H>5m PIPE MATERIAL HEIGHT OF FILLING OVER THE PIPE FROM GROUND ELEV. TO CROWN OF PIPE TYPE OF INSTALLATION CONSTRUCTION JOINT DETAIL N.B.: RAISING OF MANHOLE FRAME AND COVER JUNCTION MANHOLE COVER IN ASPHALT : 1-THE CONTRACTOR SHALL CLEAN ALL THE EXISTING STORM WATER NETWORK AS DIRECTED BY THE ENGINEER ON SITE. 2-CONCRETE ENCASEMENT SHALL BE PROVIDED WHEER THE COVER DEPTH FROM F.G.L TO CROWN OF PIPES IS LESS THAN 1.0m 3-EXACT LOCATIONS OF ROAD GULLIES AND INTERCEPTORS TO BE VERIFIED AND LOCATED BY THE CONTRACTOR ACCORDING TO THE EXISTING SITE CONDITIONS. 4-THE FINAL LEVEL ON TOP OF MANHOLE SHOULD BE VERIFIED BY THE CONTRACTOR PRIOR TO EXECUTION OF MANHOLES. 5-MANHOLE COVERS TO BE ADJUSTED ON SITE ACCORDING TO THE NEW ROADWAY FINAL GRADE LEVEL. 6-AL REINFORCED CONCRETE SHALL BE CLASS "A" AND CONCRETE FOR BLINDING SHALL BE CLASS"C". MRAYJE ION GEOMETRIC PAVEMENT DRAINAGE STRUCTURAL P. MANAGER M.B A.S H.H A.SH A.S DRAWN : A.HJ. CHECKED : M.B. APPROVED : A.S. PIPE BEDDING REQUIREMENTS FOR STORM NETWORK DATE L1702D-SW-DE-04 AS SHOWN

SPECIFICATIONS FOR THE INSTALLATION OF CONDUIT SYSTEMS IN RESIDENTIAL SUBDIVISIONS. Notification of Completed Conduit Sections

SPECIFICATIONS FOR THE INSTALLATION OF CONDUIT SYSTEMS IN RESIDENTIAL SUBDIVISIONS. Notification of Completed Conduit Sections SPECIFICATIONS FOR THE INSTALLATION OF CONDUIT SYSTEMS IN RESIDENTIAL SUBDIVISIONS Section 1 Definitions 2 Scope of Work 3 Extent of Work 4 Inspection and Performance of Work 5 Trenching 6 Duct Installation

More information

B422 - PRECAST REINFORCED CONCRETE BOX CULVERTS AND BOX SEWERS - OPSS 422

B422 - PRECAST REINFORCED CONCRETE BOX CULVERTS AND BOX SEWERS - OPSS 422 B422 - PRECAST REINFORCED CONCRETE BOX CULVERTS AND BOX SEWERS - OPSS 422 422.1 GENERAL The work under these tender items consists of the fabrication and installation in open cut of precast reinforced

More information

SECTION 8: DRAINAGE, SEWER AND WATER SUPPLY NETWORKS

SECTION 8: DRAINAGE, SEWER AND WATER SUPPLY NETWORKS UDNP Standard Specifications SECTION 8: DRAINAGE, SEWER AND WATER SUPPLY NETWORKS 8.01 - Page i UDNP Standard Specifications SECTION 8: DRAINAGE, SEWER AND WATER SUPPLY NETWORKS Table of Contents SECTION

More information

StormTrap Guide Specification. StormTrap 2 SingleTrap on Aggregate Foundation Groundwater BELOW Invert Revised 11/30/17

StormTrap Guide Specification. StormTrap 2 SingleTrap on Aggregate Foundation Groundwater BELOW Invert Revised 11/30/17 StormTrap Guide Specification StormTrap 2 SingleTrap on Aggregate Foundation Groundwater BELOW Invert Revised 11/30/17 This product guide specification is written according to the Construction Specifications

More information

EXCAVATION AND BACKFILL

EXCAVATION AND BACKFILL Standard Specification 2565.3, 2451, and 1805 A basic understanding of specifications is needed to properly replace the disturbed soil and restore the condition of the excavated area. The size of the disturbed

More information

SECTION MANHOLES

SECTION MANHOLES SECTION 02601 MANHOLES PART 1 GENERAL 1.01 SCOPE OF WORK A. WORK required under this section consists of all materials, accessories, equipment, tools, and labor required to install precast concrete standard

More information

SECTION MANHOLES

SECTION MANHOLES SECTION 33 05 13 MANHOLES PART 1 GENERAL 1.01 SECTION INCLUDES A. CONTRACTOR shall furnish and install precast concrete manhole base, sections, adjusting rings, steps, and manhole ring and cover, complete.

More information

CONSTRUCTION SPECIFICATION FOR MAINTENANCE HOLE, CATCH BASIN, DITCH INLET, AND VALVE CHAMBER INSTALLATION

CONSTRUCTION SPECIFICATION FOR MAINTENANCE HOLE, CATCH BASIN, DITCH INLET, AND VALVE CHAMBER INSTALLATION ONTARIO PROVINCIAL STANDARD SPECIFICATION METRIC OPSS 407 NOVEMBER 2013 CONSTRUCTION SPECIFICATION FOR MAINTENANCE HOLE, CATCH BASIN, DITCH INLET, AND VALVE CHAMBER INSTALLATION TABLE OF CONTENTS 407.01

More information

Grease Interceptor Design Checklist

Grease Interceptor Design Checklist CHECKLIST C2 Revised 5/2/2016 Grease Interceptor Design Checklist Public Works DISCLAIMER - This checklist is provided to Consulting Engineers for the express purpose of assisting them in compiling private

More information

Oil-Water Separator Design Checklist

Oil-Water Separator Design Checklist CHECKLIST C3 Revised 5/2/2016 Oil-Water Separator Design Checklist DISCLAIMER - This checklist is provided to Consulting Engineers for the express purpose of assisting them in compiling private oil-water

More information

StormTrap Guide Specification. StormTrap SingleTrap on Pad Foundation Groundwater BELOW Invert Revised 11/21/18

StormTrap Guide Specification. StormTrap SingleTrap on Pad Foundation Groundwater BELOW Invert Revised 11/21/18 StormTrap Guide Specification StormTrap SingleTrap on Pad Foundation Groundwater BELOW Invert Revised 11/21/18 This product guide specification is written according to the Construction Specifications Institute

More information

DESIGN OF IRRIGATION CHANNELS IN MOHAMMARA AKKAR MOHAFAZA

DESIGN OF IRRIGATION CHANNELS IN MOHAMMARA AKKAR MOHAFAZA DESIGN OF IRRIGATION CHANNELS IN MOHAMMARA AKKAR MOHAFAZA VOLUME 1 DETAILED DESIGN DRAWINGS JULY, 2017 X= 293500 Y=39500 X= 293000 X= 292500 X= 292000 X= 291500 X= 291000 X= 290500 PROPOSED IRRIGATION

More information

CITY OF MUSKEGO DRAFTING STANDARDS

CITY OF MUSKEGO DRAFTING STANDARDS CITY OF MUSKEGO DRAFTING STANDARDS GENERAL - These standards apply to all plans. 1. Plans must be prepared on sheets measuring 36 inch across and 22 inch to 24 inch high unless otherwise specified under

More information

KANSAS DEPARTMENT OF TRANSPORTATION SPECIAL PROVISION TO THE STANDARD SPECIFICATIONS, 1990 EDITION

KANSAS DEPARTMENT OF TRANSPORTATION SPECIAL PROVISION TO THE STANDARD SPECIFICATIONS, 1990 EDITION Sheet 1 of 5 KANSAS DEPARTMENT OF TRANSPORTATION SPECIAL PROVISION TO THE STANDARD SPECIFICATIONS, 1990 EDITION NOTE: This special provision is generally written in the imperative mood. The subject, "the

More information

CITY OF LA MARQUE CHAPTER GRAPHIC REQUIREMENTS CONSTRUCTION PLAN AND MISCELLANEOUS REQUIREMENTS

CITY OF LA MARQUE CHAPTER GRAPHIC REQUIREMENTS CONSTRUCTION PLAN AND MISCELLANEOUS REQUIREMENTS CITY OF LA MARQUE CHAPTER 2 -------------------------------------------- GRAPHIC REQUIREMENTS CONSTRUCTION PLAN AND MISCELLANEOUS REQUIREMENTS CHAPTER 2 ------------------------------------------------

More information

SECTION PRECAST CONCRETE SECTIONAL MANHOLES

SECTION PRECAST CONCRETE SECTIONAL MANHOLES SECTION 02545 PRECAST CONCRETE SECTIONAL MANHOLES PART 1 - GENERAL 1.01 SUMMARY A. Section Includes: 1. Precast reinforced concrete cylindrical sectional manholes, complete with openings, inserts, hardware,

More information

NEWTON COUNTY WATER AND SEWERAGE AUTHORITY RESIDENTIAL, COMMERCIAL, INSTITUTIONAL AND INDUSTRIAL SUBDIVISIONS CONSTRUCTION PLANS CHECK LIST

NEWTON COUNTY WATER AND SEWERAGE AUTHORITY RESIDENTIAL, COMMERCIAL, INSTITUTIONAL AND INDUSTRIAL SUBDIVISIONS CONSTRUCTION PLANS CHECK LIST NEWTON COUNTY WATER AND SEWERAGE AUTHORITY RESIDENTIAL, COMMERCIAL, INSTITUTIONAL AND INDUSTRIAL SUBDIVISIONS CONSTRUCTION PLANS CHECK LIST Project Name Checked By Date Designer Check List marks to be

More information

50.24 Type, Size and Location Plans for Culverts, Bridges and Culvert Bridges

50.24 Type, Size and Location Plans for Culverts, Bridges and Culvert Bridges 50.24 Culverts, Bridges and Culvert Bridges Type, Size and Location (T, S & L) Plans shall be required for all Bridges, Culvert Bridges and Culverts of eight-foot (8') clear span or greater as follows:

More information

Anne Arundel County Dept. of Inspections and Permits Water Sewer Plan Checklist

Anne Arundel County Dept. of Inspections and Permits Water Sewer Plan Checklist Project Name Project Number Engineer Plans are to be designed based on the standards set forth in the Anne Arundel County Design Manual Standards and Specifications, and all other manuals as stipulated

More information

B-PERMIT PLAN CHECK MANUAL

B-PERMIT PLAN CHECK MANUAL B-PERMIT PLAN CHECK MANUAL 5. SEWER PLANS Sewer Plans are usually submitted in conjunction with Street Plans to meet the requirements of conditions imposed on a Planning or Zoning action. In some cases

More information

SECTION 39 - MANHOLES TABLE OF CONTENTS

SECTION 39 - MANHOLES TABLE OF CONTENTS SECTION 39 - MANHOLES TABLE OF CONTENTS Section Page 39-1 GENERAL... 39.1 39-2 PRECAST CONCRETE MANHOLES... 39.1 39-2.01 Precast Concrete Sewer Manholes... 39.1 39-2.02 Precast Concrete Storm Drain Manholes...

More information

KC Water Rules and Regulations For Water Main Extensions and Relocations

KC Water Rules and Regulations For Water Main Extensions and Relocations KC Water Rules and Regulations For Water Main Extensions and Relocations MAY 2017 NOTE: Changes from 2016 are highlighted in yellow and appear on Pages 5, 8, 10-11, 13, and 15. Additional changes made

More information

SECTION III STANDARD DRAWINGS ROYSE CITY GENERAL CONSTRUCTION NOTES & DETAILS

SECTION III STANDARD DRAWINGS ROYSE CITY GENERAL CONSTRUCTION NOTES & DETAILS 9. STANDARD DETAILS SECTION III STANDARD DRAWINGS ROYSE CITY GENERAL CONSTRUCTION NOTES & DETAILS j:\clerical\royse city\1-4086 general services\168-tech const standards review\tcss manual\2018 tcss manual\sec-9a

More information

SECTION DEWATERING PART 1 - GENERAL 1.1 RELATED DOCUMENTS

SECTION DEWATERING PART 1 - GENERAL 1.1 RELATED DOCUMENTS SECTION 312319 - DEWATERING PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections,

More information

UTILITY AND STREET CONSTRUCTION PLAN REQUIREMENTS SECTION 1

UTILITY AND STREET CONSTRUCTION PLAN REQUIREMENTS SECTION 1 UTILITY AND STREET CONSTRUCTION PLAN REQUIREMENTS SECTION 1 ENGINEERING STANDARDS FOR UTILITY AND STREET CONSTRUCTION PLANS MARCH 2014 CONSTRUCTION PLAN SHEET FORMAT REQUIREMENTS REPRODUCIBLE MYLAR 1.

More information

Sewer Line Extension Permit Design Checklist

Sewer Line Extension Permit Design Checklist CHECKLIST C1 Revised 4/7/2017 Sewer Line Extension Permit Design Checklist DISCLAIMER - This checklist is provided to Consulting Engineers for the express purpose of assisting them in compiling sewer line

More information

A. Dewatering observation wells are part of dewatering allowance.

A. Dewatering observation wells are part of dewatering allowance. SECTION 312319 - DEWATERING PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections,

More information

MANHOLES PART I: GENERAL. A. Precast Concrete Manholes

MANHOLES PART I: GENERAL. A. Precast Concrete Manholes MANHOLES PART I: GENERAL A. Precast Concrete Manholes 1) Manholes shall be made of precast concrete sections of which the top section shall be eccentric or flat slab top. The bottom section shall be a

More information

Standard Specifications

Standard Specifications Standard Specifications PART 1.00 GENERAL 1.01 DECRIPTION SECTION 02620 PRECAST REINFORCED CONCRETE SANITARY MANHOLES A. Work included: The Contractor shall furnish all labor, materials, equipment, and

More information

VILLAGE OF VILLA PARK CENTRAL BOULEVARD IMPROVEMENTS LOCATION MAP (NOT TO SCALE) CORTESI AVE. MYRTLE AVE. CENTRAL BLVD.

VILLAGE OF VILLA PARK CENTRAL BOULEVARD IMPROVEMENTS LOCATION MAP (NOT TO SCALE) CORTESI AVE. MYRTLE AVE. CENTRAL BLVD. Q:\VillaPark_IL\11283000 Astor-Myrtle Sewer Separation Preliminary Design\D.4 CAD\Sheets\North\1. Cover.dwg INDEX OF SHEETS 1 COVER 2 GENERAL NOTES 3 SUMMARY OF QUANTITIES 4 ALIGNMENT 5-9 DRAINAGE AND

More information

MINIMUM DRAWING REQUIREMENTS FOR WATER AND SEWER LINE PROJECTS

MINIMUM DRAWING REQUIREMENTS FOR WATER AND SEWER LINE PROJECTS Public Works Department Water & Wastewater Services WATER & WASTEWATER ENGINEERING DIVISION 2555 West Copans Road Pompano Beach, Florida 33369 954-831-0745 FAX 954-831-0798/0925 MINIMUM DRAWING REQUIREMENTS

More information

Guidelines and Checklist For SAWS Sanitary Sewer. Developmental Engineering Division

Guidelines and Checklist For SAWS Sanitary Sewer. Developmental Engineering Division Guidelines and Checklist For SAWS Sanitary Sewer Developmental Engineering Division INITIAL CONSIDERATIONS UTILITY SERVICE AGREEMENT Utility Service Agreement A Utility Service Agreement (USA) will be

More information

PORT OF ST. HELENS SCAPPOOSE INDUSTRIAL AIRPARK PARALLEL TAXIWAY B RELOCATON AIP PROJECT ADDENDUM NO. 1

PORT OF ST. HELENS SCAPPOOSE INDUSTRIAL AIRPARK PARALLEL TAXIWAY B RELOCATON AIP PROJECT ADDENDUM NO. 1 PORT OF ST. HELENS SCAPPOOSE INDUSTRIAL AIRPARK PARALLEL TAXIWAY B RELOCATON AIP PROJECT 3-41-0056-024-2018 ADDENDUM NO. 1 Addendum No. 1 hereby amends the contract documents and drawings for the Scappoose

More information

1.1 GENERAL RECORD DRAWING REQUIREMENTS

1.1 GENERAL RECORD DRAWING REQUIREMENTS Page 1 of 5 VILLAGE OF ROMEOVILLE RECORD DRAWINGS CHECKLIST PART I GENERAL Record drawings are required to provide a means of schematic verification that the intent of the approved engineering design has

More information

SECTION DEWATERING TANKAGE PART 1 - GENERAL 1.1 RELATED DOCUMENTS

SECTION DEWATERING TANKAGE PART 1 - GENERAL 1.1 RELATED DOCUMENTS SECTION 31 23 19 - DEWATERING TANKAGE PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 1 Specification

More information

PART 4 STANDARD DRAWINGS FOR CONSTRUCTION

PART 4 STANDARD DRAWINGS FOR CONSTRUCTION 4.0. INTRODUCTION PART 4 STANDARD DRAWINGS FOR CONSTRUCTION In this document, Ivins City adopts the most recent edition (currently 2007), including all amendments, of the APWA Utah Chapter s Manual of

More information

SECTION 100 PRELIMINARY CONSIDERATIONS & INSTRUCTIONS

SECTION 100 PRELIMINARY CONSIDERATIONS & INSTRUCTIONS SECTION 100 PRELIMINARY CONSIDERATIONS & INSTRUCTIONS 101 General 102 Submittal Requirements A. Initial Submittal B. Second Submittal 103 Plan Requirements A. Subdivisions B. Site Plans 104 Approval of

More information

SPECIFICATIONS FOR THE INSTALLATION OF CONDUIT SYSTEM(S) FOR STREETLIGHTS. 1 Definitions. 2 Scope of Work. 3 Extent of Work

SPECIFICATIONS FOR THE INSTALLATION OF CONDUIT SYSTEM(S) FOR STREETLIGHTS. 1 Definitions. 2 Scope of Work. 3 Extent of Work SPECIFICATIONS FOR THE INSTALLATION OF CONDUIT SYSTEM(S) FOR STREETLIGHTS Section 1 Definitions 2 Scope of Work 3 Extent of Work 4 Inspection and Performance of Work 5 Trenching 6 Duct Installation 7 Backfilling

More information

List of Figures. List of Forms

List of Figures. List of Forms City of Columbia Engineering Regulations PART 1: SUBMISSION OF PLANS Table of Contents Paragraph Description Page No. 1.1 General 1-1 1.2 Engineer s Report 1-1 1.3 Plans 1-3 1.4 Revisions to Approved Plan

More information

TOWN of LAKESHORE SITE PLAN CHECKLIST

TOWN of LAKESHORE SITE PLAN CHECKLIST TOWN of LAKESHORE SITE PLAN CHECKLIST Last Revised December 17, 2009 Project Name: Project Location: Date Submitted: Name Phone Number E-mail Address Owner: Contractor/ Engineer: ( ) ( ) Applicant: ( )

More information

B. Installation Instructions. Provide installation instructions, including any special equipment, to address the following.

B. Installation Instructions. Provide installation instructions, including any special equipment, to address the following. SAMPLING AND TESTING. The Sampling and Testing requirements contained in -03 shall apply. MARKING. The Marking requirements contained in -03 shall apply. FINAL PRODUCTION INSPECTION. The Final Production

More information

2. Remove from the Standard Plate manual: Standard Plate Index, Sheets 1-4 of 4, Numerical Index of Standard Plates (August 31, 2012)

2. Remove from the Standard Plate manual: Standard Plate Index, Sheets 1-4 of 4, Numerical Index of Standard Plates (August 31, 2012) MINNESOTA DEPARTMENT OF TRANSPORTATION DEVELOPED BY: Design Standards ISSUED BY: Office of Program Management & Technical Support, Design Support Section TRANSMITTAL LETTER NO. (12-04) MANUAL: Standard

More information

Anne Arundel County Dept. of Inspections and Permits Storm Drain Checklist

Anne Arundel County Dept. of Inspections and Permits Storm Drain Checklist Project Name Project Number Engineer Plans are to be designed based on the standards set forth in the Anne Arundel County Design Manual Standards and Specifications, and all other manuals as stipulated

More information

SPECIFICATIONS FOR THE MANUFACTURE AND DESIGN OF PRECAST THREE SIDED ARCH STRUCTURES, WINGWALLS AND HEADWALLS

SPECIFICATIONS FOR THE MANUFACTURE AND DESIGN OF PRECAST THREE SIDED ARCH STRUCTURES, WINGWALLS AND HEADWALLS SPECIFICATIONS FOR THE MANUFACTURE AND DESIGN OF PRECAST THREE SIDED ARCH STRUCTURES, WINGWALLS AND HEADWALLS 1. DESCRIPTION THESE SPECIFICATIONS ARE FOR A PRECAST THREE SIDED ARCH STRUCTURE, HEADWALLS

More information

SECTION PUBLIC UTILITY MANHOLES AND STRUCTURES. 2. Modular precast concrete pump wetwell. 5. Manhole bedding and cover materials.

SECTION PUBLIC UTILITY MANHOLES AND STRUCTURES. 2. Modular precast concrete pump wetwell. 5. Manhole bedding and cover materials. SECTION 02082 PUBLIC UTILITY MANHOLES AND STRUCTURES PART 1 GENERAL 1.1 SUMMARY A. Section Includes: 1. Modular precast concrete manholes with tongue-and-groove joints, transition to cover frame, covers,

More information

BRASELTON WATER AND WASTEWATER DEPARTMENT CONSTRUCTION PLAN REVIEW CHECKLIST May 2006

BRASELTON WATER AND WASTEWATER DEPARTMENT CONSTRUCTION PLAN REVIEW CHECKLIST May 2006 Project Name: BRASELTON WATER AND WASTEWATER DEPARTMENT CONSTRUCTION PLAN REVIEW CHECKLIST May 2006 Phase: Unit: # Lots: Development Type (residential, commercial, industrial, etc.) Braselton Project No.

More information

Appendix C Construction Details

Appendix C Construction Details 7172 Kennedy Road Warrenton, Virginia 20187 Appendix C Construction Details November 2017 TABLE OF CONTENTS THRUST BLOCKS Anchorage for 11 1/4 o, 22 1/2 o & 45 o Upper Vertical Bends... AV 01 Buttresses

More information

CITY OF TUMWATER 555 ISRAEL RD. SW, TUMWATER, WA (360)

CITY OF TUMWATER 555 ISRAEL RD. SW, TUMWATER, WA (360) CITY OF TUMWATER 555 ISRAEL RD. SW, TUMWATER, WA 98501 (360) 754-4180 Email: cdd@ci.tumwater.wa.us WATER-SEWER-STREET-STORM (IN CITY) Submittal Checklist TUM - RCVD BY DATE STAMP APPLICANT INFORMATION

More information

MAINTENANCE HOLES, CATCH BASINS AND DITCH INLETS - MTC FORM 407 INDEX

MAINTENANCE HOLES, CATCH BASINS AND DITCH INLETS - MTC FORM 407 INDEX 407-1 - MAINTENANCE HOLES, CATCH BASINS AND DITCH INLETS - MTC FORM 407 INDEX 407-1.1 GENERAL Tender Items Specifications Standard Drawings 407-1.1.1 Frame and Grate Selection 407-1.1.2 Selection of Structure

More information

Customer Connection Guide Updates Effective May 2017

Customer Connection Guide Updates Effective May 2017 This document provides a list of the updates to the EPCOR Distribution and Transmission Inc. (EDTI) Customer Connection Guide. If you have any questions, please contact EDTI Customer Engineering Services

More information

September 21, Mannik Smith Group 1771 North Dixie Highway Monroe, Michigan RE: LA Fitness City File No.: CVLP

September 21, Mannik Smith Group 1771 North Dixie Highway Monroe, Michigan RE: LA Fitness City File No.: CVLP CITY OF ANN ARBOR, MICHIGAN Public Services Area / Engineering 301 E. Huron Street, P.O. Box 8647 Ann Arbor, Michigan 48107 Phone (734) 794-6410 Fax (734) 994-1744 Web: www.a2gov.org Printed on recycled

More information

ACSA PLAN REVIEW CHECKLIST (Guideline Only) (4) Standard water and sewer general plan notes (attached).

ACSA PLAN REVIEW CHECKLIST (Guideline Only) (4) Standard water and sewer general plan notes (attached). ACSA PLAN REVIEW CHECKLIST (Guideline Only) Revised: December 3, 2015 General (1) Proper Title (2) Vicinity map on first sheet. (3) Date and latest plan revision. (4) Standard water and sewer general plan

More information

Existing and proposed contours at 1-foot intervals. The fill and/or excavation quantities in cubic yards.

Existing and proposed contours at 1-foot intervals. The fill and/or excavation quantities in cubic yards. PLAN REQUIREMENTS The plans for street design shall conform to the requirements of Sections 3 and 4. The following requirements shall also be shown on the plans where applicable. Road and Storm Plans:

More information

For crossing under a railroad, contact the specific railroad company's engineering department.

For crossing under a railroad, contact the specific railroad company's engineering department. PAGE 330524-1 SECTION 330524 SPECIFIER: This section is for the underground installation of piping by directional drilling. When specifying this method of piping installation, care must be taken to ensure

More information

STANDARD BID ITEM NUMBERS

STANDARD BID ITEM NUMBERS 10701 TRAFFIC CONTROL LUMP SUM 10702 Traffic Control for Storm Sewer Installation LUMP SUM 10703 Traffic Control for Water Main Installation LUMP SUM 10704 Traffic Control for Sanitary Sewer Installation

More information

Page Electric Utility Service Specifications

Page Electric Utility Service Specifications T Y P I C A L U N D E R G R O U N D S E R V I C E R E Q U I R E M E N T S 200 Amps Maximum - UG-1 Sheet 1 of 3 87 T Y P I C A L U N D E R G R O U N D S E R V I C E R E Q U I R E M E N T S 200 Amps Maximum

More information

APPENDIX 1: CONSTRUCTION PLAN CHECKLIST

APPENDIX 1: CONSTRUCTION PLAN CHECKLIST APPENDIX 1: CONSTRUCTION PLAN CHECKLIST October 2017 APPENDIX A APPENDIX 1: CONSTRUCTION PLAN CHECKLIST ALL PLANS Plans on 24-inch by 36-inch paper (Originals shall be transmitted on a CD as an electronic

More information

REGISTRATION EXAMINATION, JUNE 2008 DRAINLAYING ANSWER SCHEDULE

REGISTRATION EXAMINATION, JUNE 2008 DRAINLAYING ANSWER SCHEDULE No. 9197 REGISTRATION EXAMINATION, JUNE 2008 DRAINLAYING ANSWER SCHEDULE Plumbers, Gasfitters and Drainlayers oard, 2008. All rights reserved. No part of this publication may be reproduced by any means

More information

CITY OF BEVERLY HILLS Department of Public Works and Transportation Civil Engineering Division STORM DRAIN IMPROVEMENT PLAN REVIEW CHECKLIST

CITY OF BEVERLY HILLS Department of Public Works and Transportation Civil Engineering Division STORM DRAIN IMPROVEMENT PLAN REVIEW CHECKLIST CITY OF BEVERLY HILLS Department of Public Works and Transportation Civil ing Division STORM DRAIN IMPROVEMENT PLAN REVIEW CHECKLIST The following checklist consists of the minimum requirements for preparation

More information

INSTALLATION INSTRUCTIONS. March 2016 FOR FURTHER QUESTIONS, PLEASE CALL

INSTALLATION INSTRUCTIONS. March 2016 FOR FURTHER QUESTIONS, PLEASE CALL March 2016 INSTALLATION INSTRUCTIONS FOR FURTHER QUESTIONS, PLEASE CALL 775 440 2025 JENSEN WATER RESOURCES 521 Dunn Circle, Sparks, NV 89431 JensenPumps.com Figure 1: This illustration shows a complete

More information

B17. Sewer Site Plans BULLETIN

B17. Sewer Site Plans BULLETIN BULLETIN B17 Revised 5/2/2016 Sewer Site Plans Public Works This bulletin is designed to assist you in submitting the required documentation for sewer site plans to the Pierce County Sewer Division in

More information

Manhole or Catch Basin Type A & B Cone Sections Precast - Design F Manhole or Catch Basin Cover (Reducer Cone Section Precast) Design D

Manhole or Catch Basin Type A & B Cone Sections Precast - Design F Manhole or Catch Basin Cover (Reducer Cone Section Precast) Design D MINNESOTA DEPARTMENT OF TRANSPORTATION DEVELOPED BY: Design Standards ISSUED BY: Office of Program Management and Technical Support, Design Support Section TRANSMITTAL LETTER NO. (14-02) MANUAL: Standard

More information

TIMARU DISTRICT COUNCIL 2 King George Place P.O. Box 522 Timaru 7940 Telephone: Website:

TIMARU DISTRICT COUNCIL 2 King George Place P.O. Box 522 Timaru 7940 Telephone: Website: INITIAL SURVEY ILE: CHANGES TO CORBEL DETAIL REVISION BY CHK APP. PLANNING.dwg 711696 AS SHOWN PERMISSION O THE CODE O PRACTICE TYPICAL PRECAST CONCRETE MANHOLE DETAILS 1 13 A B INITIAL SURVEY ILE: CHANGES

More information

CONSTRUCTION SPECIFICATION FOR PRECAST REINFORCED CONCRETE BOX CULVERTS AND BOX SEWERS

CONSTRUCTION SPECIFICATION FOR PRECAST REINFORCED CONCRETE BOX CULVERTS AND BOX SEWERS ONTARIO PROVINCIAL STANDARD SPECIFICATION METRIC OPSS 422 MAY 1993 CONSTRUCTION SPECIFICATION FOR PRECAST REINFORCED CONCRETE BOX CULVERTS AND BOX SEWERS 422.01 SCOPE 422.02 REFERENCES 422.03 DEFINITIONS

More information

This addendum forms a part of the Contract Documents dated: August 10, 2012.

This addendum forms a part of the Contract Documents dated: August 10, 2012. Addendum # 1 Date Issued: August 28, 2012 Issued By: Project: Owner: Renker Eich Parks Architects 1609 Dr. Martin Luther King Street North St. Petersburg, Florida 33704 Ph# (727) 821-2986 Fax # (727) 896-4911

More information

Maintenance of Traffic sequence of operations including any phasing and detour maps;

Maintenance of Traffic sequence of operations including any phasing and detour maps; All Local-let projects are required to have a Stage 2 submittal to the LPA Manager for review. The only exceptions are 2-lane resurfacing, striping, guardrail, and raised pavement markers, unless otherwise

More information

STORM M ANHOLE FOR 42" PIPE AND SM ALLER JOB NO. SHEET NO. DATE MARCH 2015 OF MIN OF 3 CRSES MAX OF 5 CRSES 30"MAX 3 OR 3.5 PRECAST ECCENTIC CONC

STORM M ANHOLE FOR 42 PIPE AND SM ALLER JOB NO. SHEET NO. DATE MARCH 2015 OF MIN OF 3 CRSES MAX OF 5 CRSES 30MAX 3 OR 3.5 PRECAST ECCENTIC CONC 01-APR-2015 13:33 = I:\MSV8i\Plotting\piblack.ptb V:\201001\\C\8x11_Howell_Det\stm_det01_8x11_st01.dgn TIME = MIN 3 CRSES MAX 5 CRSES 3 OR 3.5 PRECAST ECCENTIC CONC ID PIPE GRADE A CONC FILL 4" 8" 2-0"SUMP

More information

CHECKLIST PRELIMINARY SUBDIVISION AND PRELIMINARY SITE PLAN

CHECKLIST PRELIMINARY SUBDIVISION AND PRELIMINARY SITE PLAN N/A Waiver (1) Four (4) copies of application form. (2) Fifteen (15) copies of plan (3) Subdivision/site plan application fee & professional review escrow deposit (4) Variance application fee & professional

More information

STRUCTURES FOR SANITARY AND STORM SEWERS

STRUCTURES FOR SANITARY AND STORM SEWERS SUDAS Standard Specifications Division 6 - Structures for Sanitary and Storm Sewers Section 600 - Structures for Sanitary and Storm Sewers STRUCTURES FOR SANITARY AND STORM SEWERS PART - GENERAL.0 SECTION

More information

MEDIUM DUTY CAST IRON SLIDE GATES SERIES 20-10C

MEDIUM DUTY CAST IRON SLIDE GATES SERIES 20-10C MEDIUM DUTY CAST IRON SLIDE GATES SERIES 20-10C Revised October 2007 Armtec reserves the right to alter designs. General The Armtec Sluice Gate is a quality and highly economical gate for a variety of

More information

SECTION CONCRETE REINFORCEMENT FOR STEAM UTILITY DISTRIBUTION

SECTION CONCRETE REINFORCEMENT FOR STEAM UTILITY DISTRIBUTION PAGE 032015-1 SECTION 032015 PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification sections,

More information

3. DESIGN SPECIFICATIONS

3. DESIGN SPECIFICATIONS Schedule H to Bylaw 7452, Subdivision Bylaw Page 10 3. DESIGN SPECIFICATIONS 3.1 General 3.1.1 The Design Specifications apply to the design of sanitary sewers, storm drains, waterworks, roadways, and

More information

The Manitoba Water Services Board SECTION Standard Construction Specifications September 2013 Page 1 of 8

The Manitoba Water Services Board SECTION Standard Construction Specifications September 2013 Page 1 of 8 September 2013 Page 1 of 8 Part 1 General 1.1 DESCRIPTION OF WORK.1 The work described herein shall consist of the construction of air release chambers, flushout chambers, valve chambers, meter chambers

More information

SECTION III SUBMITTALS AND APPROVALS

SECTION III SUBMITTALS AND APPROVALS SECTION III SUBMITTALS AND APPROVALS In order to expedite the approval process of new water distribution system and sanitary sewer collection system extensions, the Hilton Head No. 1 Public Service District

More information

Government Of Newfoundland & Labrador Municipal Water, Sewer And Roads Master Construction Specifications

Government Of Newfoundland & Labrador Municipal Water, Sewer And Roads Master Construction Specifications PAGE NO. : 1 OF 4 Revision Date: July 2009 STANDARD DRAWINGS TABLE OF CONTENTS DRAWING # DESCRIPTION 0030............ Work Adjacent to Roadway 0040............ Work at the Edge of Roadway 0050............

More information

STANDARD CATCH BASIN GUTTER LINE CB INLET FRAME & GRATE, GROUTED TO GRADE RINGS AS REQ'D CONCRETE CURB FINISHED GRADE ASPHALT MAX 50 MIN

STANDARD CATCH BASIN GUTTER LINE CB INLET FRAME & GRATE, GROUTED TO GRADE RINGS AS REQ'D CONCRETE CURB FINISHED GRADE ASPHALT MAX 50 MIN CB INLET FRAME & GRATE, GROUTED TO GRADE RINGS AS REQ'D ASPHALT 20 GUTTER LINE CONCRETE CURB FINISHED GRADE PRECAST GRADE RINGS, 2 50 100 MAX PRECAST CB LID GROUT ALL AROUND CB LEAD, INSIDE & OUTSIDE OF

More information

SECTION 58 PRECAST CONCRETE BOX CULVERT. This work consists of furnishing and installing Pre-cast Concrete Box Culverts.

SECTION 58 PRECAST CONCRETE BOX CULVERT. This work consists of furnishing and installing Pre-cast Concrete Box Culverts. SECTION 58 PRECAST CONCRETE BOX CULVERT 58.1 DESCRIPTION A. General This work consists of furnishing and installing Pre-cast Concrete Box Culverts. B. Related Work Section 51 Section 52 Section 53 Section

More information

Record Drawing Standards for Projects Version 2.1

Record Drawing Standards for Projects Version 2.1 for Projects Version 2.1 Updated September 21, 2016 Department: Spatial Data Group Engineering & Maintenance 1. INTRODUCTION... 1 2. GENERAL STANDARDS... 1 2.1 Drawing Standards... 1 2.2 Digital Submission

More information

City of Massillon Site Plan Checklist

City of Massillon Site Plan Checklist City of Massillon Site Plan Checklist The following information MUST be included with all Site Plans submitted for review and processing in order to constitute a complete Site Plan Package. Incomplete

More information

Large Scale CalArc Pavers for Sand-Set Pedestrian Use Installations

Large Scale CalArc Pavers for Sand-Set Pedestrian Use Installations The following specification refers to the Stepstone, Inc. product known as: Large Scale CalArc Pavers for Sand-Set Pedestrian Use Installations Large Scale CalArc Pavers are part of the California Architectural

More information

To: New York State Department of Transportation ENGINEERING INSTRUCTION. Approved:

To: New York State Department of Transportation ENGINEERING INSTRUCTION. Approved: To: New York State Department of Transportation ENGINEERING INSTRUCTION Title: PRECAST CONCRETE PAVEMENT SLAB SYSTEMS STANDARD SPECIFICATION Distribution: Manufacturers (18) Local Govt. (31) Agencies (32)

More information

Washington County Road Engineering Plan Submittal/Review Checklist

Washington County Road Engineering Plan Submittal/Review Checklist Washington County Road Engineering Plan Submittal/Review Checklist Washington County Land Use Case File Number: Parcel(s): Developer/Owner Name(s): Developer/Owner E-mail(s): The following elements should

More information

SECTION TRACER WIRE FOR NONMETALLIC PIPE

SECTION TRACER WIRE FOR NONMETALLIC PIPE PART 1 GENERAL 1.1 DESCRIPTION A. The CONTRACTOR shall furnish and install a conductive tracer wire with all buried plastic water mains, services and appurtenances in accordance with the Water Utilities

More information

580 - NOISE BARRIERS OPSS 580 INDEX

580 - NOISE BARRIERS OPSS 580 INDEX 580 - OPSS 580 INDEX 580.1 GENERAL 580.1.1 Noise Barrier Design Elements 580.1.1.1 Wind-Load Designs 580.1.1.2 Sound-Absorptive Barriers 580.1.1.3 Noise Barrier Colour, Pattern and Texture 580.1.2 Grading

More information

CITY OF LOMPOC DEVELOPMENT ASSISTANCE BROCHURE ENCROACHMENT PERMITS AND PUBLIC IMPROVEMENT PLANS

CITY OF LOMPOC DEVELOPMENT ASSISTANCE BROCHURE ENCROACHMENT PERMITS AND PUBLIC IMPROVEMENT PLANS CITY OF LOMPOC DEVELOPMENT ASSISTANCE BROCHURE E-10 ENCROACHMENT PERMITS AND PUBLIC IMPROVEMENT PLANS The City of Lompoc has determined that the Engineering Division should administer and issue Encroachment

More information

CITY OF PITTSBURG ENGINEERING DEPARTMENT CONTRACT NO A WATER TREATEMENT PLANT CAPITAL IMPROVEMENTS PHASE 1A ADDENDUM #1 FENCE AND DITCH AUGUST

CITY OF PITTSBURG ENGINEERING DEPARTMENT CONTRACT NO A WATER TREATEMENT PLANT CAPITAL IMPROVEMENTS PHASE 1A ADDENDUM #1 FENCE AND DITCH AUGUST CITY OF PITTSBURG ENGINEERING DEPARTMENT CONTRACT NO. 2012-16A WATER TREATEMENT PLANT CAPITAL IMPROVEMENTS PHASE 1A ADDENDUM #1 FENCE AND DITCH AUGUST 2014 CHAIN LINK FENCE SPECIFICATIONS Chain link fence,

More information

CITY OF BEVERLY HILLS Department of Public Works and Transportation Civil Engineering Division SANITARY SEWER IMPROVEMENT PLAN REVIEW CHECKLIST

CITY OF BEVERLY HILLS Department of Public Works and Transportation Civil Engineering Division SANITARY SEWER IMPROVEMENT PLAN REVIEW CHECKLIST CITY OF BEVERLY HILLS Department of Public Works and Transportation Civil ing Division SANITARY SEWER IMPROVEMENT PLAN REVIEW CHECKLIST The following checklist consists of the minimum requirements for

More information

MH Table of Contents Standard Title/Scope Page Table of Contents SCE Public

MH Table of Contents Standard Title/Scope Page Table of Contents SCE Public MH Table of Contents Standard Title/Scope MH 300 MH 310 MH 318 MH 320 MH 325 MH 330 MH 335 MH 340 MH 350 Manholes Requirements MH 300.1 Manholes Requirements...........................................

More information

Clarifications in italics added July 2018

Clarifications in italics added July 2018 SECTION 10000 RECORD DRAWING CHECKLIST Clarifications in italics added July 2018 All entities who construct public infrastructure, private streets, private storm drain collection systems and travel lanes,

More information

Oakdale Primary School, Peterborough Civil Engineering NBS Specification

Oakdale Primary School, Peterborough Civil Engineering NBS Specification Oakdale Primary School, Peterborough Civil Engineering NBS Specification Prepared for Hamson Barron Smith Revision Schedule 171046 Civil Engineering NBS Specification May 2017 Rev Date Details Prepared

More information

City of Vaughan Engineering Department DESIGN STANDARD DRAWINGS

City of Vaughan Engineering Department DESIGN STANDARD DRAWINGS City of Vaughan Engineering Department DESIGN STANDARD DRAWINGS March 2004 STANDARD DRAWINGS Partners With The Environment March 2004 FORWARD The March 2004 version of the City of Vaughan Design Standard

More information

CONSULTANT ACCREDITATION SCHEME SEWER DESIGN

CONSULTANT ACCREDITATION SCHEME SEWER DESIGN CONSULTANT ACCREDITATION SCHEME SEWER DESIGN DRAWING CRITERIA AND CHECKLIST Produced by SA Water Corporation Asset Management Group June 2013 Land Developer Agreements Contact Information Details Sharyn

More information

TABLE OF CONTENTS 7.0 CABLE INSTALLATION IN UNDERGROUND STRUCTURES

TABLE OF CONTENTS 7.0 CABLE INSTALLATION IN UNDERGROUND STRUCTURES TABLE OF CONTENTS 1.0 SCOPE 2.0 BURIAL DEPTH 3.0 MINIMUM BENDING RADIUS FOR POWER CABLES 4.0 PULLING TENSIONS AND SIDEWALL PRESSURES 5.0 PARAMETERS OF CABLE PULLING 6.0 DIRECT BURIED CABLE INSTALLATION

More information

Foundation Specifications for 5.6-Meter Modular Earth Station Antennas

Foundation Specifications for 5.6-Meter Modular Earth Station Antennas Installation Instructions Bulletin 237029 Foundation Specifications for 5.6-Meter Modular Earth Station Antennas Revision A Introduction This document specifies typical foundation characteristics, designs,

More information

City of Regina Standard Construction Specification SECTION 2999 LISTING OF ROADWAY STANDARD DRAWINGS

City of Regina Standard Construction Specification SECTION 2999 LISTING OF ROADWAY STANDARD DRAWINGS City of Regina Standard Construction Specification SECTION 2999 LISTING OF ROADWAY STANDARD DRAWINGS R-1 Alternate Pavement Structures July/10 R-2 Typical Cross Sections for Asphaltic Concrete Pavements

More information

SYARIKAT BEKALAN AIR SELANGOR SDN BHD

SYARIKAT BEKALAN AIR SELANGOR SDN BHD NOTE : 1. FOR LEGEND, ABBREVIATION AND GENERAL NOTES SEE DRG. NO. SYA / STD / 001. 2. ALL DIMENSIONS ARE IN mm UNLESS OTHERWISE STATED. 3. ACTUAL LENGTH OF PE COMMUNICATION PIPES SHALL BE DETERMINED ON

More information

MAJOR GRADING PLAN CHECKLIST

MAJOR GRADING PLAN CHECKLIST MAJOR GRADING PLAN CHECKLIST PUBLIC WORKS DEPARTMENT / ENGINEERING DIVISION 8130 Allison Avenue, La Mesa, CA 91942 Phone: (619) 667-1166 Fax: (619) 667-1380 Grading plans shall address both rough grading

More information

Engineering and Construction Services Division Construction Drawings for Sewers and Watermains. T No. Revision T No. Revision Remarks All T drawings

Engineering and Construction Services Division Construction Drawings for Sewers and Watermains. T No. Revision T No. Revision Remarks All T drawings Engineering and Construction Services Division Construction Drawings for Sewers and Watermains Revision No. 8 April All T drawings New title block for each drawing is now standardized. Revision numbers

More information

Construction Tolerances - The following tolerances apply to cast-in-place structures:

Construction Tolerances - The following tolerances apply to cast-in-place structures: 00540.40(b) Construction 00540.40 Tolerances - The following tolerances apply to cast-in-place structures: (a) Foundation Footings: (1) Lateral Alignment: Actual (as cast) location of the center of gravity:

More information

Foundation Specifications for 7.6-Meter Modular Earth Station Antennas

Foundation Specifications for 7.6-Meter Modular Earth Station Antennas Installation Instructions Foundation Specifications for 7.6-Meter Modular Earth Station Antennas Bulletin 237186A Revision A Introduction This document specifies typical foundation characteristics, designs,

More information