ADAPT. ABILITY. X 6.50" Example of a continuous row. Shown: hanging the fixture via threaded rods.
|
|
- Barnaby Morrison
- 5 years ago
- Views:
Transcription
1 AMELUX Suspension Points 6.50" GUV4-HE-FLANGE; GUV6-HE-FLANGE Gyp Board Ceiling INSTALLATION INSTUCTIONS SHEET #: SHEET 1 of 9 (SHEETS 1-4) T5/T5HO (SHEET 5) T5/T5HO LUXOTTICA (SHEETS 6-9) LED X 6.50" SPEC. SHEET EFEENCE: GUV4-HE-FLANGE GUV6-HE-FLANGE WANING - ISK OF FIE AND ELECTICAL SHOCK. FIXTUE MUST BE INSTALLED BY A QUALIFIED ELECTICIAN ONLY. FIXTUE IS INTENDED FO INSTALLATION IN ACCODANCE WITH THE NATIONAL ELECTICAL CODE, LOCAL AND FEDEAL SPECIFICATIONS. DISCONNECT POWE AT ELECTICAL PANEL BEFOE SEVICING. ETAIN THESE INSTUCTIONS FO MAINTENANCE EFEENCE. 6.50" X 13.00" X 6.50" Example of a continuous row 1. Individual or Bo (Beginning of ow) Installation Shown: hanging the fixture via threaded rods. Mounting rods and hardware by others ACCESS PLATE DETAIL FEED WIING CONNECTIONS Additional connections (not shown) as required for dimming, EM or other wiring requirements will be labeled. Cap all unused leads. Wire nuts supplied by others. 1. Cut opening in ceiling to be [3 3/4" for GUV, or 5 3/4" for GUV6] wide X [O.A.L.(as specified) minus 3/4"] (maintain square cut over length). 2. emove lens. 3. Loosen screws to remove reflector assembly (STOE SAFELY). 4. Make sure power is off at electrical panel. emove access plate on top of housing. Knock out K.O. as required. Make electrical connections (see detail). 5. einstall access plate on housing. 6. emove 5/16" K.O.'s Install threaded rods or blocking (Blocking by others) Note height dimensions. (See Detail) 7. Guide fixture into ceiling and mount via threaded rod, or directly into blocking. Secure with hardware (by others) 8.If INDIVIDUAL, reinstall reflector, install lamps, remove shipping brace and install lens. Snap-in lens Amerlux, LLC Daniel oad East, Fairfield NJ T: F:
2 AMELUX GUV4-HE-FLANGE; GUV6-HE-FLANGE Grid Ceilling INSTALLATION INSTUCTIONS SHEET #: SHEET 1 of 9 (SHEETS 1-4) T5/T5HO (SHEET 5) T5/T5HO LUXOTTICA (SHEETS 6-9) LED SPEC. SHEET EFEENCE: GUV4-HE-FLANGE GUV6-HE-FLANGE WANING - ISK OF FIE AND ELECTICAL SHOCK. FIXTUE MUST BE INSTALLED BY A QUALIFIED ELECTICIAN ONLY. FIXTUE IS INTENDED FO INSTALLATION IN ACCODANCE WITH THE NATIONAL ELECTICAL CODE, LOCAL AND FEDEAL SPECIFICATIONS. DISCONNECT POWE AT ELECTICAL PANEL BEFOE SEVICING. ETAIN THESE INSTUCTIONS FO MAINTENANCE EFEENCE. Suspension Points 6.6" X 6.6" 6.6" X 13" X 6.6" Individual Installation - Example of a continuous row FIXTUES TO BE INSTALLED PE NEC "MEANS OF SUPPOT" AND ALL FEDEAL, NATIONAL AND LOCAL BUILDING CODES. 5/16" KO'S provided for rod suspensions rods not by Amerlux Mounting rods and hardware by others 1. CEILING GID TO BE INSTALLED (BY OTHES) 2.) INSTALLING CONTACTO TO VEIFY CEILING GID HEIGHT AND BEND-OUT APPOPIATE FIXTUE TAB (TYPICAL 4 PLACES). 3.) MAKE SUE SHIPPED BACE IS SECUE DUING INSTALLATION, LIFT FIXTUE INTO PLACE IN CEILING GID, HANDLE FIXTUE CAEFULLY TO AVOID BOWING AND/O FIXTUE DISTOTION. INSTALL FIXTUE INTO CEILING GID, MAKING SUE FIXTUE FLANGE ESTS ON CEILING GID AND BEND-OUT TABS AE THEN PESSED SECUELY AGAINST CEILING GID (SEE BEND #1), THEN BEND-OVE AGAINST BOTTOM OF GID BULB (SEE BEND #2) NOTE: TO PEVENT FIXTUE FOM LIFTING DUING LENS INSTALLATION 4.) E.C. TO SECUE FIXTUE PE NEC CODE, VIA THEADED OD, WIE TIES O OTHE MEANS (HADWAE SUPPLIED BY E.C.) 5.) MAKE SUE POWE IS OFF AT ELECTICAL PANEL. EMOVE ACCESS PLATE ON TOP OF HOUSING. KNOCK OUT K.O. AS EQUIED, MAKE ELECTICAL CONNECTIONS (SEE ACCESS PLATE DETAIL PAGE 2) 6.) E-INSTALL ACCESS PLATE TO HOUSING. 7.) INSTALL COECT LAMPS. 8.) EMOVE SHIPPING BACE AND INSTALL LENS. 9/16" Slot Grid shown for ref. GUV4 (3 3/16") GUV6 (5 3/16") SNAP-IN LENS FIXTUE FLANGE Contractors esponsibility to keep this dimension before & after installation. Shipping Brace Loosen screw to remove Amerlux, LLC Daniel oad East, Fairfield NJ T: F:
3 Support Methods - (Threaded od/blocking) *NOTE AMELUX INSTALLATION INSTUCTIONS SHEET #: SHEET 2 of 9 2 1/2" Housing sides have tabs with 3/16" x 3/8" slots for optional mounting to side blocking, (2) per side Mounting rods and hardware by others OD BLOCKING* 2. Assembling Continuous ows- (Socket/reflector assemblies must be removed. All fixtures must be fully supported by rod or blocking.) I. Mo (Middle of un) Join the housings Align the two housings via (4) alignment pins. Press fit together. Secure Mo housing in position via rod or blocking. Secure joint with 8-32 x 1/2" SEMS screws and lock nuts as shown. Mo 8-32 x 1/2" SEMS screws and lock nuts for joining fixtures (2 ea.) Alignment pins (4) Bo Amerlux, LLC Daniel oad East, Fairfield NJ T: F:
4 AMELUX INSTALLATION INSTUCTIONS SHEET #: SHEET 3 of 9 II. Install Eo (End of un) Bo or Mo A. Hammer in (4) alignment pins of last installed Bo or Mo housing until flush with end of housing. Eo B. Install Eo straight up into ceiling aperture flush or nearly flush with end of installed fixture. Fully support fixture in joining position via rod or blocking. C. Secure joint with 8-32 x 1/2" SEMS screws and lock washers as detailed on previous page. GUV4 Eo GUV6 Bo or Mo -O- Eo Bo or Mo D (GUV4). Loosen (1) 8-32 screw on each splice bracket pre-installed in Eo* and slide brackets into adjacent housing. etighten screws and secure to adjacent housing with 8-32 screws supplied. D (GUV6). Locate (2) alignment pins accessible from inside Bo or Mo housing (the same ones hammered in in Step A). Use a flat blade screwdriver to slide these approximately 3/4" into Eo housing for final alignment. * Splices and hardware may ship in bagged kit for field installation in location TBD by contractor. Amerlux, LLC Daniel oad East, Fairfield NJ T: F:
5 AMELUX INSTALLATION INSTUCTIONS SHEET #: SHEET 4 of 7 III. Install reflector assemblies END OF UN FILLE Quick Disconnect Squeeze Squeeze END OF UN FILLE 1. Insert the reflector into housing. 2. Secure reflector to upper area of extrusion via screws. - For continuous runs, connect each reflector assembly via quick connect plugs before installation. - For staggered lamp fixtures, filler pieces will be supplied for the beginning and end of the run. They are to be secured to the extrusion the same way as the reflector assemblies. To reinstall lens, start at one end. squeeze lens legs IN to snap lens in place. Continue pressing upward across length of fixture until lens is secure. 1. Install correct lamps. 2. Ballast maintenance. See relamping label on reflector for the correct wattage. Ballasts are located on opposite side of reflector. emove the screws mounting the reflector to access. Amerlux, LLC Daniel oad East, Fairfield NJ T: F:
6 AMELUX Suspension Points INSTALLATION INSTUCTIONS SHEET #: SHEET 5 of 9 GUV4-HE-FLANGE; GUV6-HE-FLANGE, FLUOESCENT, LUXOTTICA Gyp Board Ceiling 9 1/8" X 9 1/8" SPEC. SHEET EFEENCE: GUV4-HE-FLANGE GUV6-HE-FLANGE WANING - ISK OF FIE AND ELECTICAL SHOCK. FIXTUE MUST BE INSTALLED BY A QUALIFIED ELECTICIAN ONLY. FIXTUE IS INTENDED FO INSTALLATION IN ACCODANCE WITH THE NATIONAL ELECTICAL CODE, LOCAL AND FEDEAL SPECIFICATIONS. DISCONNECT POWE AT ELECTICAL PANEL BEFOE SEVICING. ETAIN THESE INSTUCTIONS FO MAINTENANCE EFEENCE. Individual Installation - 2/3 5b 1 1. Turn height adjustment screw clockwise until spring hanger assembly is at its highest point. 2. Cut Opening in ceiling to be (4" for GUV, or 6" for GUV6) wide X O.A.L. (as specified) minus 3/4" (maintain square cut over length) 3. Insert blocking above gypsum board to act as fixture mounting point. Attach blocking to above structure, making sure blocking will not move vertically during fixture installation. Screw gypsum board to blocking using drywall screw, spackle and sand. 4. emove Access Plate on top of housing. emove K.O.s as required, Make electrical connections. e-install access plate into housing. 5. Guide fixture into ceiling hole. Push fixture vertically until fixture flange is against ceiling. Springs will open as fixture is raised and "teeth" of spring clear blocking. 6. Turn height adjusting screws counter-clockwise until fixture flange is against ceiling. 7. remove shipping braces, install lamps (by others, wattages as stated on relamping label), install lens. 5a 6 MAINTENANCE 1. Install correct lamps. 2. Ballast maintenance. See relamping label on reflector for the correct wattage. Ballasts are located on opposite side of reflector. emove the screws mounting the reflector to access. Amerlux, LLC Daniel oad East, Fairfield NJ T: F:
7 AMELUX Suspension Points 6.50" GUV4-HE-FLANGE; GUV6-HE-FLANGE, LED Gyp Board Ceiling INSTALLATION INSTUCTIONS SHEET #: SHEET 6 of 9 X 6.50" SPEC. SHEET EFEENCE: GUV4-HE-FLANGE GUV6-HE-FLANGE WANING - ISK OF FIE AND ELECTICAL SHOCK. FIXTUE MUST BE INSTALLED BY A QUALIFIED ELECTICIAN ONLY. FIXTUE IS INTENDED FO INSTALLATION IN ACCODANCE WITH THE NATIONAL ELECTICAL CODE, LOCAL AND FEDEAL SPECIFICATIONS. DISCONNECT POWE AT ELECTICAL PANEL BEFOE SEVICING. ETAIN THESE INSTUCTIONS FO MAINTENANCE EFEENCE. 6.50" X 13.00" X 6.50" Example of a continuous row 1. Individual or Bo (Beginning of ow) Installation Shown: hanging the fixture via threaded rods. Mounting rods and hardware by others ACCESS PLATE DETAIL FEED WIING CONNECTIONS 0-10V DIM shown. For non-dim applications cap Purple (+) and Gray (-). Wire nuts supplied by others. 1. Cut Opening in ceiling to be [3 3/4" for GUV, or 5 3/4" for GUV6] wide X [O.A.L.(as specified) minus 3/4"] (maintain square cut over length). 2. emove lens. 3. Loosen screws to remove reflector assembly (STOE SAFELY). Electrostatic discharge warning. Ground before handling. 4. Make sure power is off at electrical panel. emove access plate on top of housing. Knock out K.O. as required, Make electrical connections (see detail). 5. einstall access plate on housing. 6. emove 5/16" K.O.'s. Install threaded rods or blocking (blocking by others). Note height dimensions (see detail). 7. Guide fixture into ceiling and mount via threaded rod or directly into blocking. Secure with hardware (by others). 8. If INDIVIDUAL, reinstall reflector, install lamps, remove shipping brace and install lens. Snap-in lens Amerlux, LLC Daniel oad East, Fairfield NJ T: F:
8 Support Methods - (Threaded od/blocking) *NOTE AMELUX INSTALLATION INSTUCTIONS SHEET #: SHEET 7 of 9 2 1/2" Housing sides have tabs with 3/16" x 3/8" slots for optional mounting to side blocking, (2) per side Mounting rods and hardware by others OD BLOCKING* 2. Assembling Continuous ows- (LED reflector assemblies must be removed. All fixtures must be fully supported by rod or blocking.) I. Install Mo (Middle of un) Join the housings Align the two housings via (4) alignment pins. Press fit together. Secure Mo housing in position via rod or blocking. Secure joint with 8-32 x 1/2" SEMS screws and lock nuts as shown. Mo 8-32 x 1/2" SEMS screws and lock nuts for joining fixtures (2 ea.) Alignment pins (4) Bo Amerlux, LLC Daniel oad East, Fairfield NJ T: F:
9 AMELUX II. Install Eo (End of un) INSTALLATION INSTUCTIONS SHEET #: SHEET 8 of 9 Bo or Mo A. Hammer in (4) alignment pins of last installed Bo or Mo housing until flush with end of housing. Eo B. Install Eo straight up into ceiling aperture flush or nearly flush with end of installed fixture. Fully support fixture in joining position via rod or blocking. C. Secure joint with 8-32 x 1/2" SEMS screws and lock washers as detailed on previous page. GUV4 Eo GUV6 Bo or Mo -O- Eo Bo or Mo D (GUV4). Loosen (1) 8-32 screw on each splice bracket pre-installed in Eo* and slide brackets into adjacent housing. etighten screws and secure to adjacent housing with 8-32 screws supplied. D (GUV6). Locate (2) alignment pins accessible from inside Bo or Mo housing (the same ones hammered in in Step A). Use a flat blade screwdriver to slide these approximately 3/4" into Eo housing for final alignment. * Splices and hardware may ship in bagged kit for field installation in location TBD by contractor. Amerlux, LLC Daniel oad East, Fairfield NJ T: F:
10 AMELUX INSTALLATION INSTUCTIONS SHEET #: SHEET 9 of 9 III. Install LED reflector assemblies LED Driver - Some reflectors might have end filler installed at one side. Two screws next to LED board allow adjustment of filler position if required. ed/black Harness Squeeze Squeeze ed/black Harness To reinstall lens, start at one end, squeeze lens legs IN to snap lens in place. Continue pressing upward across the length of the fixture until lens is secure. - For multiple reflector fixtures, connect each reflector assembly to the driver installed in the housing before installation. Each reflector has to be connected the same way it was connected by the factory. MAKE SUE TO DISCONNECT ALL ELECTICAL CONNECTIONS BEFOE SEVICING. WANING: Electrostatic and polarity sensitive device. Use caution while handling and wiring. 1.) LED Fixture: Consult Amerlux for LED maintenance. 2.) LED eplacement: For LED board replacement reference Instruction Sheet 3.) Driver maintenance. Drivers are located on tray beneath indirect reflectors. emove reflector mounting screws to access. For programmable driver replacement please specify: Manufacturer, Model No. and Current Setting ( ma). See Wiring Schematic for more details. Amerlux, LLC Daniel oad East, Fairfield NJ T: F:
CABLE MOUNTED FOR INDIVIDUAL FIXTURES OR CONTINUOUSLY ROW MOUNTED
AMELUX Pre-installation Note: Supplied by others: - 4" octagonal junction boxes LIN3.5D LED (SHEETS 1-4) LS35D T5/T5HO (SHEETS 5-6 ) CABLE MOUNTED FO INDIVIDUAL FIXTUES O CONTINUOUSLY OW MOUNTED SHEET
More informationLIGHT FIXTURES MUST BE COMPLETELY INSTALLED PRIOR TO CEILING CONSTRUCTION
CAUTION: BEFORE BEGINNING INSTALLATION REVIEW LAYOUT DRAWINGS, AND SHIPMENT. MAKE SURE ALL LIGHT S AND MATERIALS ARE ON SITE AND READILY ACCESSIBLE. IF ANY ICON MATERIALS ARE MISSING, CONTACT ICON INTERNATIONAL
More information- 2 JOINER ALIGNERS - 2 JOINING BRACKETS - 4 HEX BOLTS. Factory pre-installed mud flange TOOLS REQUIRED: Phillips screwdriver, 5/16 nut driver.
- 2 JOINER ALIGNERS - 2 JOINING BRACKETS - 4 HEX BOLTS TruGroove Drywall A3 MOUNTING Ceiling INSTALLATION System Overview These instructions review how to install drywall trim versions of TruGroove recessed
More informationINSTALLATION: D1-NOTCH DRYWALL TRIM FLANGE
T F W 604.549.979 604.549.9555 fluxwerx.com INSTALLATION: D1-NOTCH DRYWALL TRIM FLANGE fixture housing endcap kit optic kit join kit notch 2 cross section notch 4 cross section 4 4" 4-11/2" 4 /8 (111)
More informationInstallation Instructions Standalone or continuous run configurations - 2 JOINER ALIGNERS - 2 JOINING BRACKETS - 4 HEX BOLTS
- 2 JOINER ALIGNERS - 2 JOINING BRACKETS - 4 HEX BOLTS TruGroove Drywall A3 MOUNTING Ceiling INSTALLATION System Overview These instructions review how to install trimless drywall versions of TruGroove
More informationEXPLODED VIEW AND PART CALL OUT ASSEMBLING THE METALUX DF SERIES FRAME KIT
EXPLODED VIEW AND PART CALL OUT CUTOUT DIMENSIONS ON PAGE 2 CEILING BRACING (BY OTHERS) SHEET ROCK METALUX DF SERIES FRAME KIT S282 (2'X2') FIXTURE SHOWN FIXTURE SIZE FRAME KIT PART # 2' X 2' DF-22W-U
More informationLightplane 3.5 Recessed
INSTALLATION INSTRUCTIONS Lightplane 3.5 Recessed LP3.5R Recessed Ceiling IMPORTANT SAFETY INSTRUCTIONS When installing or using this fixtures basic safety precautions must be followed. Read all instructions
More informationSAVE THESE INSTALLATION INSTRUCTIONS
Light Without Boundaries LUMATO RESERVES THE RIGHT TO CHANGE PRODUCT 7500003 8/4 Light Without Boundaries LUMATO RESERVES THE RIGHT TO CHANGE PRODUCT GENERAL INSTALLATION WARNING To Reduce Risk Of Death,
More informationBLUEMOTION UXP, CDP, SD
Feed and Support Kit Contents FEED KIT CONTENTS: - One () 7 Feed Cord - One () 4 Canopy - One () Grommet - One () Threaded Barrel - One () 7 Swedged Suspension Cable - One () Y-Cable Assembly with Cable
More informationBionic 4 PERIMETER, CONTINUOUS RUN X3, X7
I NSTALLAT ION INSTRUC TIONS 6 3 /4 6 3 /4 3¾ 5 1 /2 For LP installs, ceiling opening is equal to row length + 3 /4 8 1 /2 4 3 /32 5 1 /4 Flush X7 Shown PARTS SHIPPED SEPARATELY 4 3 /32 5 1 /4 3" Regressed
More informationSAE of 7 "R" (REGRESSED) POSITION "S" (SHIELDING AT TOP) POSITION. Tools Required
SAE 0 5/6'' Exposed TBar Ceiling FINISHED EDGE WITH JANGLE 90 IC CORNER KIT 5 7/6" 38mm 9/6'' Screw Slot TBar Ceiling "R" (REGRESSED) POSITION 6" CEILING OPENING "S" (SHIELDING AT TOP) POSITION SUPPORT
More information5 ACCESS PANEL INSTALLATION SPACER *SLIDE TO LOCATION OF FASTENER DURING INSTALLATION OF EACH FASTENER
1/2 K.O. (3/8 K.O. on 165 with factory supplied 3/8 flex conduit fitting) TR - Trim Flange Side Blocking Install Method Secure fixture to structure following instructions below: 1. Remove lens and internal
More informationINSTALLATION INSTRUCTIONS FIXTURE SERIES: SAE 202 MOUNTING TYPE: RECESSED WALL / SLOT PAGE: 1 OF 8
INSTALLATION INSTRUCTIONS FIXTURE SERIES: SAE 202 MOUNTING TYPE: RECESSED WALL / SLOT PAGE: 1 OF 8 90v INNER CORNER KIT "R" (REGRESSED) POSITION CROSS-SECTION VIEW "S" (SHIELDING AT TOP) POSITION CROSS-SECTION
More informationHP-2 / HP-4 / HP-6 Ceiling to Wall Inside Corner Installation Instructions Overview
Overview Step 4 Mounting to Structure Page 6 Step 1 Mounting Locations & Rough-Ins Pages 2-3 Step 2 Identification & Preparation Page 4 Step 6 Securing Corner Joints Page 8 Step 3 Opening Luminaires Page
More informationINDIVIDUAL MOUNTING: T-Bar
X1 (T-BAR) INSTALLATION INSTRUCTIONS GENERAL NOTES NOTE : Additional support to structural member may be required. Check with local building codes for requirement. 1. Place troffer clamp approx. 6 from
More informationGeneral Installation Instructions
General Installation Instructions WARNING To reduce the risk of death, injury or property damage from fire, electric shock, cuts, abrasions, falling parts and other hazards: Service of the equipment must
More informationRound or Square Type IC Wall Wash Housing with Lamp for Flangeless Trims
Installation Instructions for 90ELED-WIC Round or Square Type IC Wall Wash Housing with Lamp for Flangeless Trims LED E_L_-L_WI. LED - ROUND/ SQUARE FLANGELESS GENERAL PRODUCT I NFORMATION: This product
More informationEOS LED Surface Mounted Luminaire
Installation Instruction Sheet INSTALLATION INSTRUCTIONS FOR JOINING AND SUSPENDING FIXTURES WARNING WARNING To reduce the risk of death, injury or property damage from fire, electric shock, cuts, abrasions,
More informationMultiples EM_ 1.4. Install 1X1/1X2/1X3/1X4 Housings. Installation Instructions for. This product is suitable for indoor locations.
Installation Instructions for 90EMULTI Multiples EM_. GENERAL PRODUCT I NFORMATION: This product is suitable for indoor locations. This product can be dimmed with a standard electronic dimmer or a 0-0V
More informationLINESSE LINEAR LUMINAIRE 3 CEILING MOUNT CM2420
Linesse Linear Luminaire 3 Ceiling Mount LINESSE LINEAR LUMINAIRE 3 CEILING MOUNT Page 2: Warnings Page 3: Mounting Configurations Page 4: Power Feed Page 5: Surface Mounting Page 6: Threaded Rod Mounting
More informationHP-2 / HP-4 Wall Wash Recessed Spackle & Visible Flange Installation Instructions Overview
Overview NOTES All power connections should be installed according to local/national codes by a Certified Electrician. This installation requires proper support as each luminaire is being installed. DO
More informationPOLYBAG KIT JOINER STRAP FIXTURE TYPE ROLL OF DOUBLE SIDED TAPE REQUIRED FOR R/POSITION WALL ANGLES (SEE STEP 6) 12"LG U-ANGLE (3) U-CLIPS
STRAIGHT EXTENSION [SE] P/C PG. OF NOTES: STRAIGHT EXTENSIONS (SE) ARE INSTALLED AT ENDS OF ROW TO CLOSE OFF CEILING OPENING. A. FIXTURES MUST BE INSTALLED PRIOR TO ATTACHING STRAIGHT EXTENSIONS. B. STRAIGHT
More informationDRYWALL CEILING SPLINE KICKER REFLECTOR DIFFUSER LENGTH TABLE DIFFUSER LENGTH TABLE DESCRIPTION 2' IND 3' IND 4' IND 6' IND 8' IND
SUPPLEMENTAL INSTALLATION TYPE LG-WWD-44, R-WWD-44 & RP-WWD-44 510553-2000 WHICH IS CONTRARY TO THE CONTAINED HEREIN. P/C PG. 1 OF 1 1/4-20 THREADED ROD OR EQUAL SUPPLIED PANHEAD SHEET METAL SCREW HEX
More informationHO4 Surface Mount Installation Instructions Overview
Overview Step 4 Mounting to Structure Pages 5-6 Step 5 Joining Luminaires Pages 7-8 Step 1 Mounting Types & Locations Page 2 Step 6 Closing Luminaires Page 9 Helpful Video 0-10V Dimming Step 2 Identification
More informationLF Series Assembly Instructions
LF Series Assembly Instructions 1998760 Revision A-10 Complete Series Master Packet 2010 Kimball International, Inc. T 800.482.1818 F 812.482.8300 Footprint Storage and Metal Filing Systems Assembly Instructions
More informationInstall the Housing. Installation Instructions for Entra Round or Square Type IC, Air-tight New Construction Adjustable LED Housing EN3_-LH9_ 1.
Installation Instructions for Entra Round or Square Type IC, Air-tight New Construction Adjustable LED Housing 90ENTRA EN_-LH9_. LED - ROUND/ SQUARE GENERAL PRODUCT I NFORMATION: This product is safety
More informationInde-Pendants Family. 32L Surface Mount Cylinder with Ring Plaster Trim, Grid and Drywall Ceiling Types. Document No
Inde-Pendants Family 32L Surface Mount Cylinder with Ring Plaster Trim, Grid and Drywall Ceiling Types Installation instructions for 32L-CRxx-S-D Document No. Supplied by Litecontrol 32L Inde-Pendants:
More informationJoiner Kit Joiner bracket (x1) Biscuit aligners (x2) Trim Flange
- Trim System Overview These instructions review how to install TruGroove Perimeter fixtures. Modules can be installed as individual standalone units, or they can be joined together to create continuous
More information+ - 1a. 1b. c. 1d. 1e. Runway Suspended / Surface Cont. Run Installation. 2.0mm DIL DIL Revision - M 23/11/2018 Page 1
230-240V / 50-60Hz IP20 IK00 + - 2.0mm WARNING - THIS LUMINAIRE MUST BE EARTHED This luminaire has been tested and is manufactured to comply with BS EN 60598 : specification for general requirements and
More informationDiva Acoustical Ceiling
Installation Instructions Diva Acoustical Ceiling CONTENTS Important User Information...........................2 Safety Precautions.................................3 Required Tools....................................3
More informationFigure A. Figure B. Figure C. Figure D
Xsite 1 Power/Data Tile and Components Tools Required Tape Measure Cordless Drill/Driver #2 Phillips Screw driver bit Rubber Mallet Flat Blade Screwdriver Figure A Hardware Required Provided as shown Installation
More informationRound or Square Chicago Plenum Down Light Housing with Lamp
Installation Instructions for 90ELED-DCP Round or Square Chicago Plenum Down Light Housing with Lamp LED E_-L_DC. LED - ROUND/ SQUARE GENERAL PRODUCT I NFORMATION: This product is suitable for indoor locations.
More informationSTEP 1 - CEILING PREPARATION
STEP 1 - PREPARATION 1/4-20 THREADED RODS SR FIXTURE SLOT/ IN SHEET ROCK WHIP A) MAKE SLOT IN SHEET ROCK ACCORDING TO RUN INFORMATION, TYPE OF FIXTURE AND REFER TO S REQUIRED (FIGURE 2 - SR* AND FIGURE
More informationRound or Square Type IC Down Light Housing with LED Lamp for Flangeless Trims E3_L_-L_DI 1.4
Installation Instructions for 90ELED-DIC Round or Square Type IC Down Light Housing with LED Lamp for Flangeless Trims E_L_-L_DI. LED - ROUND/ SQUARE FLANGELESS GENERAL PRODUCT I NFORMATION: This product
More informationTHIS SHEET CONTAINS IMPORTANT SAFETY INSTRUCTIONS. SAVE THESE INSTRUCTIONS.
LumeLEX 2026 SERIES INSTALLATION INSTRUCTIONS Important THIS SHEET CONTAINS IMPORTANT SAFETY INSTRUCTIONS. SAVE THESE INSTRUCTIONS. Warning This product must be installed in accordance with National Electrical
More informationInde-Pendants Family. 32L Ring Plaster Trim, Grid and Drywall Ceiling Types. Document No Installation instructions for 32L-Rxx-P
Inde-Pendants Family 32L Ring Plaster Trim, Grid and Drywall Ceiling Types Installation instructions for 32L-Rxx-P Document No. Supplied by Litecontrol 32L Inde-Pendants: Ring (Plaster Trim, Grid and Drywall
More informationHP-2 / HP-4 Wall Wash Recessed T-Bar Installation Instructions Overview
HP-2 / HP-4 Wash Recessed T-Bar Installation Instructions Overview NOTES All power connections should be installed according to local/national codes by a Certified Electrician. This installation requires
More informationGeneral Installation Instructions LED
General Installation Instructions LED To reduce the risk of death, personal injury or property damage from fire, electric shock, falling parts, cuts/abrasions and other hazards, please read all warnings
More informationINSTALLATION INSTRUCTION Silo Multiples - New Construction Housing MT-4*15, MT-4*10
IMPORTANT SAFETY INSTRUCTIONS 1. Read all instructions before installing. 2. System is intended for installation by a qualified electrician in accordance with the National Electrical Code and local regulations.
More informationLINESSE LINEAR LUMINAIRE 3 RECESSED CV2424
Linesse Linear Luminaire 3 Recessed LINESSE LINEAR LUMINAIRE 3 RECESSED Page 2: Warnings Page 3: Mounting Types and Dimensions Page 4: T-Grid and Joining Fixtures Page 5: Hard Ceiling and Joining Fixtures
More informationModular & Hardwired Hub Assembly to "X" and "Y" Posts
Modular & Hardwired Hub Assembly to "X" and "Y" Posts Hardware Package T-Nut Data jack bracket #6 x 1/4" plastite trilobular screw 1/4-20 x 3/4" socket head cap screw #6-32 x 1/4" pan head screw #10-32
More informationGared Pro-S Portable Backstop
Models: 9616 & 9618 Installation, Operation and Maintenance Instructions Please read all instructions before attempting installation or operation of these units SAVE THESE INSTRUCTIONS FOR FUTURE USE PUBLICATION
More informationINSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS
FOR RECESSED EDGE-LIT LED EXIT SIGN Standard and New York Approved Models (Emergency, non-emergency and X2 Dual Circuit operation) READ AND FOLLOW ALL SAFETY INSTRUCTIONS IMPORTANT SAFEGUARDS: When using
More informationP.O. Box 8400 Green Bay, WI (920)
P.O. Box 8400 Green Bay, WI 54308-8400 (920) 468-2165 Change Notice No. 112 Implemented By: KI-Pembroke Notification By: Scott Vissers Date: 03/15/10 Component Product Title: Series XXI Lateral Filing
More informationRAIL 4 PERIMETER RP4D RECESSED T-BAR LED TELESCOPIC, INTEGRAL DRIVER
INSTALLATION INSTRUCTIONS RAIL 4 PERIMETER RP4D RECESSED T-BAR LED TELESCOPIC, INTEGRAL DRIVER NOTE: The following instructions provide general guidelines for product installation. For additional information
More informationTrack Rack. * Track Racks are not lockable
The Track Rack s unique staggered, sliding hook design creates the greatest parking efficiency while still providing easy access to any particular bike. When adding or removing a bike to the rack, simply
More information2. Connect driver to power source leads. After connections are made, place driver above ceiling. SEE MINIMUM SPACE REQUIREMENTS BELOW.
INSTALLATION INSTRUCTIONS INSTALLATION: 1. Cut proper opening in ceiling. Round: 140mm Ø, Square: 140mm x 140mm 140mm Ø 140mm x 140mm 2. Connect driver to power source leads. After connections are made,
More informationInde-Pendants Family. 32L Surface Mount Cylinder Plaster Trim, Grid and Drywall Ceiling Types. Document No
Inde-Pendants Family 32L Surface Mount Cylinder Plaster Trim, Grid and Drywall Ceiling Types Installation instructions for 32L-C-S-D Document No. Supplied by Litecontrol 32L Inde-Pendants: Cylinder (Surface
More informationTH Place, Maspeth, NY Instruction Manual for UNO Exit Signs
57-10 49 TH Place, Maspeth, NY 11378 Instruction Manual for UNO Exit Signs 1. What is included in this box? Back box with electronics, battery (where applicable), & mounting hardware. Inner trim, LED illuminator
More informationHealthcare LED TROFFER FLANGE (HSTLED Family)
Healthcare LED TROFFER FLANGE (HSTLED Family) Applies to all HSTLED production after 6/1/2015 (reference CI-Code *231V2F and later) Revision 04 I-HSTLED-FLANGE Revision Date 6/11/2015 Healthcare Lighting
More informationSAM. Model: STV-C65 LCD Mobile Visualized Stand Instruction Manual. Weight Capacity: 1251bs / 56.7kg Suits LCD Flat Panel Display: 42"-55" Page 20
SAM Model: STV-C65 LCD Mobile Visualized Stand Instruction Manual Weight Capacity: 1251bs / 56.7kg Suits LCD Flat Panel Display: 42"-55" 20 Step 6 LCD Mobile Lift Stand Model: STV-C65 Cable management
More informationINSTALLATION INSTRUCTIONS
Sheet 1 of 5 General: Upon receipt of fixture thoroughly inspect for any freight damage, which should be brought to the attention of the delivery carrier. Compare the catalog description listed on the
More informationSUPERPLANE TM 4 RECESSED SP4R
Oakland, INSTALLATION INSTRUCTIONS SUPERPLANE TM RECESSED SPR TGrid ATZ Slot n A 1035 22nd Avenue, Unit 1 CA 606 P 510.8.2530 E TalkToUs@alwusa.com W alwusa.com SPR - Safety & Warnings! 1. Read all instructions.
More informationINSTALLATION INSTRUCTIONS FOR FLUSH MOUNT FIXTURES
Kurt Versen Company Point Source Lighting Models with Round Apertures 10 Charles Street Westwood, New Jersey 1 PLEASE READ THIS ENTIRE INSTRUCTION SHEET BEFORE INSTALLATION. 2 DISCONNECT ELECTRICAL POWER
More informationSeriesTWO RGB Fluorescent Fixtures. Installation and Instruction Manual
SeriesTWO RGB Fluorescent Fixtures Installation and Instruction Manual Brightline LP 580 Mayer Street #7, Bridgeville PA 15017 Phone 1-412-206-0106 Fax 1-412-206-0146 www.brightlines.com The Brightline
More informationAIR MASTER SYSTEMS INSTALLATION GUIDE TABLE OF CONTENTS
AIR MASTER SYSTEMS INSTALLATION GUIDE TABLE OF CONTENTS GENERAL INFORMATION...1 Freight Damage... 1 Repairing Paint Scratches...1 BASE CABINETS... 2 Drawer Removal and Reinstallation...2 Replacing Drawer
More informationMirage Installation Manual
Mirage Installation Manual General Information This installation manual provides necessary information for the safe installation of the Mirage product. WARNING: Failure to follow the instructions in this
More informationPORTA~TRACE. GAGNE, INC. 41 Commercial Dr. Johnson City, New York Phone: Fax: ASSEMBLY INSTRUCTIONS
PORTA~TRACE GAGNE, INC. 41 Commercial Dr. Johnson City, New York 13790 Phone: 1-607-729-3366 Fax: 1-607-729-7644 ASSEMBLY INSTRUCTIONS PORTA~TRACE MODEL 2436T LIGHT TABLE PORTA~TRACE MODEL 3648T LIGHT
More informationAssembly Instructions
InTandem Table System November 20 InTandem Table System - Worksurface #4 x/" 4 wood screw power beam Tools Provided T-0 Extended Torx Driver T-25 Torx Driver Additional Tools Required Soft protective
More informationBaby Grande with Crank, Housing, and Side Rails Installation Instructions
Baby Grande with Crank, Housing, and Side Rails Installation Instructions Tools Needed Hardware Provided (per shade) Hardware Needed Drill 3/8 Metal Drill Bit ¼ Masonry Drill Bit Measuring Tape Pencil
More informationEOS Direct/Indirect LED Pendant Luminaire
Installation Instruction Sheet INSTALLATION INSTRUCTIONS FOR JOINING AND SUSPENDING FIXTURES WARNING WARNING To reduce the risk of death, injury or property damage from fire, electric shock, cuts, abrasions,
More informationMPA-9000 Universal Ceiling Projector Mount Kit
I N S T R U C T I O N M A N U A L Universal Ceiling Projector Mount Kit The Universal Ceiling Projector Mount provides a unique, simplified method of ceiling mounting your inverted projector. This low
More informationHP-2 Recessed Wall Wash Flush Diffuser Tech Zone 4" Starter/Independent Installation Instructions
HP-2 Recessed Wall Wash Flush Tech Zone /Independent Scan QR code for helpful video(s) Step 1 Step 2 Tech Zone Collection. Center-to-center spacing Wall 0-10V Dimming.0.0.0 Tech Zone (C1) Tech Zone (C2)
More informationRAIL 4 INSTALLATION INSTRUCTIONS. RM4DOD Recessed GENERAL SAFETY INSTRUCTIONS: NOTE:
INSTALLATION INSTRUCTIONS RAIL 4 RM4DOD Recessed NOTE: The following instructions provide general guidelines for product installation. For additional information consult the applicable electrical codes
More information-Always de-energize the circuit and/or equipment before connecting to, disconnecting from or servicing the equipment.
W3 Direct and W3 Indirect/Direct Series Products WARNING To Reduce Risk Of Death, Injury Or Property Damage From Fire, Electric Shock And Other Hazards: -Service of equipment must be performed by qualified
More informationCONTENTS TOOL LIST U P S I D E I N N O V A T I O N S, L L C RAMP AND STEP SYSTEM ASSEMBLY INSTRUCTIONS. Revised: June 2013
U P S I D E I N N O V A T I O N S, L L C RAMP AND STEP SYSTEM ASSEMBLY INSTRUCTIONS TOOL LIST Required Tools: - Reciprocating Saw with Metal Cutting Blade - Drill - 7/16 Drill Bit for Metal Drilling -
More informationPORTABLE ADJUSTABLE BASKETBALL SYSTEM
Instruction Manual PORTABLE ADJUSTABLE BASKETBALL SYSTEM P A R T S L I S T 5 1/2 and 8 safe play clearance Item Qty Description Item Qty Description A 1 Portable Base Assembly M 4 1/2 Lock Nut B 2 Front
More informationUser Instructions Multiline Otter Scoreboard Caddy Assembly
List of parts: User Instructions Multiline Otter Scoreboard Caddy Assembly Single Caddy Double Caddy 1 1 Base assembly with attached wheels 2 4 1 1 2 4 4 8 10 20 12 Uprights (60 or 74 aluminum extrusion)
More informationAssembly Instructions for Model: VMPR1
Assembly Instructions for Model: VMPR1 Thank you for choosing a Sanus Systems Model: VMPR1 ceiling mount. The VMPR1 ceiling mount provides a unique, simplified method of ceiling mounting inverted LC/LP
More informationINSTALLATION MANUAL PBL-UMP
INSTALLATION MANUAL PBL-UMP Table of Contents Warning Statements... 4 Parts List... 5 Installation Tools... 5 Features... 7 Projector Preparation... 8 Bracket Installation... 10 Leveling the Mounting Bracket...
More informationSmartView Mounting Frame 3 Wide x 3 Deep Video Wall Display Installation Guide
SmartView Mounting Frame 3 Wide x 3 Deep Video Wall Display Installation Guide WMK-034 This display kit mounts ViewSonic 46 Video Wall displays in a 3 wide by 3 deep landscape configuration. The frame
More informationF l a t S c r e e n A R M S I n s t a l l a t i o n
ITEM NUMBERS (1) #TOACAORG16 (2) #TOACAORG20 (3) #TOACATRP24 (4) #TOACATRP30 (5) #TOACATRPDS (6) #TOACATRPSS TOOLS REQUIRED (1) 3/8 Wrench (not provided) (2) Phillips head screwdriver (not provided) (1)
More informationOxford Stalls Installation Instructions
Oxford Stalls Installation Instructions RAMM Horse Fencing and Stalls 13150 Airport Hwy. Swanton, OH 43558-9615 1-800-434-8456 Rev. 8/15/17 Before You Start Typical stall sizes are 10 x 10, 12 x 12 or
More informationABM International, Inc. Navigator Assembly Manual
ABM International, Inc. 1 1.0: Parts List Tablet (Qty. 1) Tablet mount (Qty. 1) NOTE: Mount may appear and operate different then image below Control Box (Qty. 1) Motor Power Supply (Qty. 1) 2 X-axis motor
More information1?4" SHEET METAL SCREW APERTURE GAUGE. Housing Aligner Spline HOUSING ALIGNER SPLINE PANHEAD SCREW. #10 x.1875 SMS. Aligner/ Seam Joiner
HOUSING ALIGNER SPL P33 INSTALLATION DRAWINGS X3 (HARD CEILING) PARTS (SHIPPED SEPARATELY) 8/32 x 1/2 PHD S.T. SCREW REMOVAL TOOL TROFFER CLAMP 1/4 Sheet Metal Screw Housing Aligner Spline HOUSING ALIGN
More informationLine volt rail & fixtures. Low volt quick connect fixtures with transformers
INSTRUCTIONS: Line Volt Flexrail2 Safety Instructions: A qualified electrician must install system only. System is intended for installation in accordance with National Electric Code, local and Federal
More informationHawko Zhaga Systems Installation Instructions
Hawko Zhaga Systems Installation Instructions Contents Wire Suspension Installation 4 Recessed Brackets 6 Fixed Suspension Rods 8 Swivel Suspension Rods 10 Surface Mount Ceiling 12 Surface Mount Wall
More informationFlowBar Architectural Linear Diffusers F L- 1 0 / F L-15 / FL-2 0 F L- 2 5 / F L-30 I NSTA LL AT IO N & OPER AT I ON M AN UA L
I NSTA LL AT IO N & OPER AT I ON M AN UA L FlowBar Architectural Linear Diffusers F L- 1 0 / F L-15 / FL-2 0 F L- 2 5 / F L-30 I OM F L-1 0/ FL- 15 /FL-20 /FL-25/FL-3 0 FlowBar Installed During Hard Ceiling
More informationPrivacy Wall & Glass Selections Pivot-Hinged Door (For products manufactured after September 14, 2009)
Privacy Wall & Glass Selections Pivot-Hinged Door (For products manufactured after September 14, 2009) 3/16" HEX BIT #2 ACR BIT 3/8" HEX SOCKET Full-Height (No Switch) Transom (No Switch) Full-Height (With
More informationAngled Side Flush with Panel Face
Identify and sort panels by like sizes, fabrics, surface type (tackable vs hard), and NON- POWERED vs POW- ERED. Non-powered panels ship without a powerway. Powered panels include a powerway. See below.
More informationMotorized or Crank Operated Fortress Zipper Track Shade with Housing and Side Track Installation Instructions
Motorized or Crank Operated Fortress Zipper Track Shade with Housing and Side Track Installation Instructions Tools Needed Drill 3/8 Metal Drill Bit ¼ Masonry Drill Bit Measuring Tape Pencil 4 Level Phillips
More informationEDGE Evolution Outline
EDGE Evolution Outline INSTALLATION INSTRUCTIONS Outline Installation....2-5 Outline End Filler Installation...6-9 Outline Outside Corner Installation...10-13 Outline Inside Corner Installation...14-19
More informationLow Headroom Rear Mount TorqueMaster
Low Headroom Rear Mount Supplemental Instruction Insert This supplemental installation instruction is to be used as a supplement to the main Installation Instruction and Owner s Manual provided with the
More informationDOWNLIGHT LED SERIES INSTALLATION INSTRUCTIONS
WARNING: This product must be installed in accordance with the applicable installation code by a person familiar with the construction and operation of the product and the hazards involved. Make sure all
More information101B, 210X, ELM, VSTB Installation Manual
101B, 210X, ELM, VSTB Installation Manual 99-16105-I001 Copyright 2010 by ALL rights reserved. Information in this document is subject to change without notice. Companies, names and data used in examples
More informationRowan Chandelier. Assembly Instructions CAUTION: Important Safety Instructions: WARNING: Pre-assembly:
owan handelier ssembly Instructions UTION: BEFOE INSTLLING FIXTUE, MKE SUE THE POWE TO THE IUIT IS TUNED OFF T THE MIN FUSE BOX / IUIT BEKE UTILITY BOX. Do not install into a ceiling that contains radiant
More informationMANUAL INSTALLATION. Linear Bar Grille - Heavy Duty LBPH/LBMH. v000 Issue Date: 09/17/ Price Industries Limited. All rights reserved.
MANUAL INSTALLATION Linear Bar Grille - Heavy Duty LBPH/LBMH v000 Issue Date: 09/17/18 2018 Price Industries Limited. All rights reserved. TABLE OF CONTENTS Product Overview Overview...1 Before You Start...2
More informationSapper XYZ 30 Monitor Arm Installation Instructions
12/01/2017 Sapper XYZ 30 Monitor rm Installation Instructions at 60% from original 59065 Step 1: ttach Mount to Work Surface Two-Piece Table lamp and eep Table lamp llen wrenches (in inches): lamp lower
More informationAssembly Instructions for Model: VMPL3
Assembly Instructions for Model: VMPL3 Thank you for choosing a Sanus Systems VisionMount Wall Mount. The VMPL3 is designed to hold 27-84 Flat Panel LCD or Plasma Displays weighing up to 280 lbs. It will
More informationUR20/UR28 Ouro Site/Area Luminaire Installation Instructions
17760 Rowland Street City of Industry, CA 91748 626/968-5666 FAX 626/369-2695 UR20/UR28 Ouro Site/Area Luminaire Installation Instructions! WARNING: Fixtures must be grounded in accordance with local codes
More informationINSTALLATION INSTRUCTIONS DODGE RAM 2 & 4WD 1500 PART # P5058
INSTALLATION INSTRUCTIONS 2009-13 DODGE RAM 2 & 4WD 1500 PART # P5058 PARTS LIST: Qty Description Qty Description 1 Grille Guard 12 12-1.75mm Hex Nuts 2 Upper Frame Mounting s (for trucks without tow hooks
More informationTrendWall Floor-To-Ceiling Panels Installation Instruction
TrendWall Floor-To-Ceiling Panels Installation Instruction TrendWall Components Covered by this Instruction: Crown (and accessories) Floor Plate Solid Panel Filler Panel Wall Channel Door Section Pilaster
More informationINSTALLATION INSTRUCTIONS
INSTALLATION INSTRUCTIONS SOLID PHENOLIC TOILET PARTITIONS 1080 DuraLineSeries Class-A Fire Rated Includes Institutional Hardware Option.67 IMPORTANT: Storage and Handling Information on last page. Review
More informationInstallation Instructions
EZ Launch Accessible Transfer System Installation Instructions Models 500900L, 500900R, 500901L, 500901R 500890, 500906L, 500906R For questions about features, operation/performance, parts, accessories
More information3 wide x 3 deep Video Wall Display Installation Guide
HoverTrack Series 3 wide x 3 deep Video Wall Display Installation Guide VWD-3X3-X462 This display kit mounts NEC X461UN and X462UNS LCD monitors in a 3 wide by 3 deep landscape configuration. The frame
More informationRevised
Indentify Non-powered panels and separate from Powered panels. Non-powered panel shown at left.. Powered panel shown at left has powerway mounted at factory. Also separate panels by surface type, width
More informationWARNING: Prior to installation, turn the power off to the vending machine and unplug it from its power source. Also, make sure to level the machine.
Installation of Gum and Mint Tray for National 147, 157, 167 Important Note: Please read all instructions thoroughly before continuing with installation of kit. If you are having problems installing the
More informationSystem 3000 specifications
System 3000 specifications Scope: Materials: Type of Bookstack: This specification covers delivery and installation of steel library shelving of the bracket type. Height, depth and accessories shall be
More informationHatch Whiteboard: Portable Stand Installation Instructions
Hatch Whiteboard: Portable Stand Installation Instructions Remove Projector Wall Plate 1. Open the wall mount for the projector. 2. Remove the shipping screw from the front center of the mount arm. 1 P
More informationINSTALLATION INSTRUCTIONS
SC4 / SC5 LC4 / LC5 CURVED ARMS SEE NOTE #5 & #6 FIXTURE HEAD FIXTURE INSTALLATION 1) TURN OFF POWER. 2) ADJUST FIXTURE HEAD TO THE DESIRE POSITION AND SECURE WITH (2) BUTTON HEAD SCREWS. 3) MAKE WIRE
More information