1 Digital Modules AS-i in 22,5 mm Cost efficient solution in IP20 (Figure similar) Figure Type Housing s digital digital voltage (sensor supply) 1 Output voltage (actuator supply) 2 AS-i connection 3 AS-i address Article No. 22,5mm x 50mm, x out of AS-i out of AS-i clamps 1 AB Slave x x x x 22,5mm x 11mm, 6 x 22,5mm x 11mm, 6 x 6x 6x out of clamps 1 AB Slave BWU2723 out of out of clamps 1 AB Slave BWU1938 out of out of clamps 1 Single Slave BWU out of clamps 2 AB Slaves BWU x 8x out of out of clamps 2 AB Slaves BWU290 out of out of clamps 2 Single Slaves BWU voltage (sensor supply): inputs are supplied by AS-i or by (auxiliary 2V power). If supplied by AS-i, inputs can neither be connected to earth nor to external potential. 2 Output voltage (actuator supply): the supply of the outputs is made by AS-i or by (auxiliary 2V power). By supply out of AS-i there is no connection to earth or external potential allowed. 3 : the connection to AS-i as well to (auxiliary 2V power) is either made via yellow AS-i profile cable with piercing technology or via M12 socket (in IP20 via clamps). AS-i address: AB Slave (max. 62 AB Slaves/AS-i network), 2 AB Slaves (max. 31 modules with 2 AB Slaves), Single Slaves (max. 31 Single Slaves/AS-i network), mixed use allowed (upon request, slaves are available with specific AS- Slave profiles). We reserve the right to change any data Mannheim, page 1
2 Digital Modules AS-i in 22,5 mm Article no. BWU1938 BWU2759 BWU2723 BWU2721 BWU290 BWU2800 Connection Periphery connection Length of connector cable AS-i Profile I/O: max. 15m (fixed) ID1=F AS-i address 1 AB Slave 1 single slave plug plug unlimited ID1=6 (fixed), ID1=6 ID1=F ID1=E 1 AB Slave 2 AB Slaves 2 single slaves Operating voltage V Required Master profile M M0 M3 M M0 Since AS-i specification Max. current consumption 165mA 35mA 60mA Voltage V Max. current consumption - A 1,2A 8A Number 8 Power supply out of AS-i out of Power supply of attached sensors 120mA max. 1,2A permanent operation 3 ( in- and outputs = max. 120mA) 1 Switching threshold U<5V (low) U>15V (high) Output Number x x 8 x, short circuit protected Power supply out ofas-i out of out of Max. output current 120mA ( in- and 1A ( 3A max.) 1A ( 3A max. O1-O, 3A max. O5-O8) outputs = max. 120mA) 1 Display LED (green) on: AS-i voltage on, flashing: AS-i voltage on, but peripheral fault 2 or address 0 off: no AS-i voltage LED /FAULT (red) on: slave address 0 or slave offline flashing: peripheral fault 2 off: slave online LED / 1 (red/green) green: slave online red: slave offline yellow/red flashing: address 0 red/green flashing: peripheral fault 2 page 2 Mannheim, We reserve the right to change any data
3 Digital Modules AS-i in 22,5 mm Article no. BWU1938 BWU2759 BWU2723 BWU2721 BWU290 BWU2800 LED / 2 (red/green) green: slave online red: slave offline yellow/red flashing: address 0 red/green flashing: peripheral fault 2 red flashing: slave 2 is switched off, because slave 1 is offline LEDs In (yellow) state of inputs State of inputs I8 LEDs O1 On (yellow) state of outputs O1-O state of outputs O1-O8 LED (green) on: 2V DC off: no 2V DC Environment Applied standards EN EN Operating temperature -25 C -25 C +70 C +55 C Storage temperature -25 C +85 C Protection category DIN EN IP20 Voltage of insulation 500V Dimensions (W / H / D) in mm 22, / 99,6 / 50,5 22,5 / 99 / 11 1 Derating current ma see Installation instruction/manual C operating temperature Derating BWU1938, BWU290, BWU2721, BWU2723, BWU2759, BWU2800 current A C operating temperature at operating temperature >60 C: Σ 1A max. We reserve the right to change any data Mannheim, page 3
4 Digital Modules AS-i in 22,5 mm connections I- I+ O- O- O1 O O2 O3 BWU1938 / BWU2759 +, - s O1 O O1 O2 O3 O + + I I + O 2 O 1 I I 3 I 2 I 1 I 2 I 3 I 1 I O 2 O 3 O 1 O FAULT ADDR I I + O 2 O 1 I I 3 I 2 I 1 I 2 I 3 I 1 I O 2 O 3 O 1 O FAULT ADDR s O1 O O 2 O 3 O 1 O + NC NC I I+ O O I 8 I 7 I 6 I 5 I I 2 I 1 D1 I6 D2 I7 I5 I8 / D1 / D2 ADDR D1 ADDR D2 O1 O O2 D1 O3 O5 O8 O6 D2 O7 O1 O2 O3 O O5 O6 O7 O8 + + O 1 O 2 O 3 O + NC NC + BWU290 / BWU2800 +, - I8 s O1 O8 I- I+ I- I+ BWU2723 +, - PWR INT nc nc nc nc + + I- I+ I- I+ I5 I8 I6 I7 BWU2721 +, - I8 PWR INT ADDR page Mannheim, We reserve the right to change any data
5 Digital Modules AS-i in 22,5 mm module BWU1938 / BWU290 / BWU2721 / BWU2723 / BWU2759 / / BWU2800 Output module BWU1938 / BWU290 / BWU2759 / / BWU2800 I+ Ix O- O1 O2 Ox Separate power supply 2V (s) 0V 2V () I+ Ix + - Programming BWU1938 / BWU2723 / BWU2759 / Bit setting D0 D1 D2 D3 BWU290 / BWU2721 / BWU2800 I5 I6 I7 I8 Output BWU1938 / BWU2759 / O1 O2 O3 O BWU290 / BWU2800 O1 O2 O3 O O5 O6 O7 O8 Parameter bit P0 P1 P2 P3 BWU290 / BWU2800 not used, watchdog always on not used not used BWU2723 / BWU2721 BWU1938 / BWU2759 0= off / 1= on (peripheral fault, if no voltage) 0= off / 1= on (watchdog) 0= on / 1= off (data input filter 128μs) 0: on / 1: off (synchronous I/O mode) We reserve the right to change any data Mannheim, page 5
Analog Modules AS-i IP20
(Figure similar) Figure Type Inputs analog 4... 20 ma / 4... 20 ma / 4... 20 ma Pt100 4 x thermocouple type J 4 x thermocouple type K Outputs analog 0... 20 ma / 0... 20 ma / -10 V... +10 V Input voltage
More informationAcceleration sensors With relay output for limit monitoring Analog / CANopen
Features Acceleration sensor / analog / CANopen Up to two relay outputs for limit monitoring 3 axes detection, MEMS based Measuring range ±2 g Connection: connector M12, 12-pin Offshore capability (plastic
More informationElectronic Circuit Breaker ESS1 for System SVS1
Electronic Circuit Breaker for System SVS Description The electronic circuit breaker is designed to ensure selective disconnection of individual s in industrial systems which are powered by a DC 24 V switch
More information7.2 DV1311.L08 and DV1311.L12
7. DV.L08 and DV.L 7.. General information The DV.L08 and DV.L modules let you control valve manifolds using multi-pin technology. There are two types of valve control modules available for delivery, which
More information02/11/2015
Standstill monitoring KSW3-JS Part number 85102331 Function "Stillstand detection without sensors" Independent of rotation direction Security with redundancy and feedback circuit 3 forcibly guided "NO"
More informationData Sheet KFD2-UFC-EX1.D. Supplied by. .com. Call us on +44 (0)
Data Sheet KFD-UFC-EX1.D Supplied by.com Call us on +44 (0)118 916 940 Email info@47able.com Frequency Converter with Trip Values Features Assembly 1-channel isolated barrier 4 V DC supply (Power Rail)
More informationElectronic Circuit Breaker ESS1 for System SVS1
Electronic Circuit Breaker for System SVS Description The electronic circuit breaker is designed to ensure selective disconnection of individual s in industrial systems which are powered by a DC 24 V switch
More informationTemperature controller, 4-channel
, 4-channel Subject to technical modification 716218 Identification Type TR-1-6218 4-channel Part-No. 716218 Use/Area of application Description The temperature controller has 4 separate channels. The
More informationK AS-Interface. K Test input
U RL.-/... Reflection light beam switch with polarisation filter RL.-/... with terminal compartment K Detection range up to 8 m, optional 4 m K Compact construction K Light/dark switch RL--ASI/3 K Sensitivity
More information8V General information. 2 Order data 8V
8V80.00-8V80.00- General information Modular mechanical design using plug-in modules Integrated line filter Integrated or optional external braking resistor All connections are made using plug-in connectors
More informationOperating Instruction
Level and Pressure Operating Instruction VEGASEL 643 6 5 + + 3 5 + + max. min. on VEGASEL 643 5 6 7 8 9 10 11 12 13 14 in out Contents Contents Safety information... 2 1 Product description 1.1 Function
More informationAssembly. Front view. DIP switch. LED yellow: Relay output 1. LED yellow: Relay output Power Rail
Current/Voltage Trip Value Features Assembly 1-channel signal conditioner 24 V DC supply (Power Rail) Current and voltage input 2 relay outputs Programmable high/low alarm Configurable via DIP switches
More informationProduct Information ECI 1319S EQI 1331S. Absolute Rotary Encoders without Integral Bearing and with DRIVE-CLiQ Interface.
Product Information ECI 1319S EQI 1331S Absolute Rotary Encoders without Integral Bearing and with DRIVE-CLiQ Interface Firmware 15 12/2018 ECI 1319S, EQI 1331S Rotary encoders for absolute position values
More informationEFX IO84 Input/Output Module
EFX IO84 Input/Output Module Input/Output expansion module for EFX Controllers CANopen interface Surface electrostatically coated (cathodic immersion) 10...32V DC Technical Data Housing Dimensions (l x
More informationE-STOP relays, safety gate monitors
Safety relay for monitoring E-STOP pushbuttons, safety gates and light barriers. Approvals Unit features Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous 1 auxiliary contact (N/C),
More information8V General information. 2 Order data 8V
8V05.00-8V05.00- General information Modular mechanical design using plug-in modules Integrated line filter Integrated braking resistor All connections are made using plug-in connectors Integrated electronic
More informationEP-5111, EP-5112, EP-5212, EP-5261, EP-5311, EP-5422, EP-5442
October 2017 RSTI-EP Slice I/O Specialty Modules EP-5111, EP-5112, EP-5212, EP-5261, EP-5311, EP-5422, EP-5442 Module Status LED Channel Status LED GE provides several RSTi-EP specialty modules, which
More informationAssembly. Front view. DIP switch. LED yellow: Relay output I. LED yellow: Relay output II. Potentiometer Hysteresis relay I Power Rail
Current/Voltage Trip Value Features Assembly 1-channel signal conditioner 24 V DC supply (Power Rail) Current and voltage input 2 relay outputs Programmable high/low alarm Configurable via DIP switches
More informationWLL 170 Photoelectric switches with fibre-optic cable, red light, manual sensitivity adjustment -- DC. Dimensional drawing R1.6 2-R
WLL 0 Photoelectric switches with fibre-optic cable, red light, manual sensitivity adjustment -- DC 0... 0 mm Through-beam systems Dimensional drawing R. -R. Scanning distance 0... 0 mm. Proximity systems
More informationProduct Information. EQN 1337 F Absolute Rotary Encoder with Tapered Shaft for Fanuc Controls with i Interface
Product Information EQN 1337 F Absolute Rotary Encoder with Tapered Shaft for Fanuc Controls with i Interface 11/2017 EQN 1337 F Rotary encoders for absolute position values Installation diameter 65 mm
More informationDigital Input Module 24 V Ex n Inputs, 16 Channels Series 9471
> 16 channels for active 0 / 24 V signals > Zone 2 / Division 2 version for connection of circuits acc. to Ex nl, Ex na, Nonincendive and Non-Ex > Galvanic separation between inputs and system > Two channels
More information02/11/2015
35 mm - 1 Relay 8A OUR3 Part number 88867103 Multi-function or mono-function Multi-range Multi-voltage Relay output 1 or 2 : 8 A - 250 V (10 A UL) LED status indicator Option of connecting an external
More informationIBS IP CDIO/R 24-8 IBS IP CDIO/R 24-8/SF
IBS IP CDIO/R 24-8 IBS IP CDIO/R 24-8/SF Data Sheet INTERBUS Digital I/O Module for Use on Robots Revision C1 05/2000 Product Description The modules are designed as compact I/O units for use on robots.
More informationsuppression, insensitive to optical interference, sensor E photoelectric switch, areas Zone 2 (gas) and Zone 22 (non-conductive dust).
KD0_Ex_D_G_en.qxd 0.08.00 Photoelectric proximity switches BGS Photoelectric reflex switches Through-beam photoelectric switches 0:8 Uhr Seite 08 Ready-to-fit and Standardcompliant - Cat. D/G Photoelectric
More informationOFF-delay time. 7.5 s. 15 s. 30 s. Main contacts Auxiliary contact Number of input channels Rated voltage Model Category
Safety Relay Unit Four kinds of -mm wide Units are available: A -safety contact model, a -safety contact model, and models with safety contacts and OFF-delay safety contacts. Also available are 7.-mm wide
More informationPI2794. Flush pressure sensor with display. 1 alphanumeric display 4-digit 2 status LEDs 3 programming button. Made in Germany
1 alphanumeric display 4-digit 2 status LEDs 3 programming button Made in Germany Application Application hygienic systems Media viscous media and liquids with suspended particles; liquids and gases Medium
More informationElectronic Circuit Breaker ESS20-0..
Description Electronic circuit breaker type ES-0.. is designed to ensure selective disconnection of individual loads in systems which are powered by a DC 4 V switch-mode power supply. DC 4 V power supplies,
More informationRevision to the Operating Instructions
Drive Technology \ Drive Automation \ System Integration \ Services Revision to the Operating Instructions SEW-EURODRIVE GmbH & Co KG P.O. Box 3023 D-76642 Bruchsal/Germany Phone +49 7251 75-0 Fax +49
More informationIncremental Shaft Encoders Industrial types
Synchro flange! Universal industry standard encoder! Up to 40,000 steps with 10,000 pulses! High signal accuracy! Protection class up to IP 67! Operating temperature up to 100 C (RI 58-T)! Flexible due
More informationInstallation / Monitoring Technique
Installation / Monitoring Technique VARIMETER RCM Residual Current Monitor, Type B for AC and DC Systems IP 5883 0249633 IP 5883 ND 5018/035 ND 5018/030 According to IEC/EN 62 020, VDE 0663 For AC and
More informationThroughbeam photoelectric sensors. Dimensioned drawing. Transmitter/receiver Optical axis LED yellow 90 turning connector. Electrical connection
Specifications and description Leuze electronic LSR 8 Throughbeam photoelectric sensors Dimensioned drawing,5 khz 0-30 V DC A 2 LS A²LS - active suppression of extraneous light Push-pull switching outputs
More informationHighlights Very compact EtherCAT I/O system in IP 20 for plug-in into a circuit board (signal distribution board)
550. Highlights Very compact EtherCAT I/O system in IP 20 for plug-in into a circuit board (signal distribution board). Optimised for high-volume production Application-specific connector interface EtherCAT
More informationPositive-guided relay outputs: 8 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous
Contact expander module for increasing the number of available contacts Approvals Unit features Positive-guided relay outputs: 8 safety contacts (N/O), instantaneous 1 auxiliary contact (N/C), instantaneous
More informationOutput of three-phase motors at 50 Hz and 400 V
RT0, RH Coupling Relays (Interfaces) Description DC operation IEC 0 947 and EN 0 947 (VDE 00) The RT0 coupling relays for switching motors and RH for auxiliary circuits are laid out to the special requirements
More informationCAN-IO Custom IO remote module
CAN-IO Custom IO remote module Main characteristics High customization Integrate different types of inputs/ outputs Up to 40 total channels DIN rail mount or plate Main applications Climatic chambers Autoclaves
More information02/11/2015
35 mm - 2 Relays 8A PL2R1 Part number 88867455 Multi-function or mono-function Multi-range Multi-voltage Relay output 1 or 2 : 8 A - 250 V (10 A UL) LED status indicator Option of connecting an external
More informationPortable equipment for insulation fault location for unearthed and earthed systems (IT and TN systems) to be used in conjunction with or without an
EDS309 Portable equipment for insulation fault location for unearthed and earthed systems (IT and TN systems) to be used in conjunction with or without an equipment for insulation fault location EDS309x_D00012_00_D_XXEN/05.2015
More informationIST-KIT-UR-G Page 1 of 9 KIT-UR-G REVISIONS
Page 1 of 9 MOUNTING INSTRUCTIONS AND OPERATING MANUAL KIT-UR-G REVISIONS DATE REVISION MAIN CHANGES 2017/10/17 Edition A First release 2017/11/23 Edition B Replaced jaws screws (old VITE-016, new VITE-031)
More informationThe universal input/output device is a DIN rail mounted device. It is connected to the EIB via a bus connecting terminal.
, GH Q631 0026 R0111 SK 0097 B97 The universal input/output device is a DIN rail mounted device. It is connected to the EIB via a bus connecting terminal. The device has 32 freely programmable inputs/outputs,
More informationLC1D25BL TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 25 A - 24 V DC coil
Product data sheet Characteristics LC1D25BL TeSys D contactor - 3P(3 NO) - AC-3 -
More informationDiffuse reflection light scanner with background suppression. Dimensioned drawing. Electrical connection. see remarks!
Dimensioned drawing 1 5mm 1-3 V D Scanner with adjustable background suppression Two switching points Individual adaptation to applications by means of programming and diagnosis software Universal sensor
More informationPART NUMBERING SYSTEM
Plug-In Timer pins Multifunction or monofunction Compact body for space saving Wide time range (from 0. seconds to 0 days delay) niversal power supply (-0 Vz) or relay outputs (SPDT / Changeover) Protective
More information400,440Vac Vdc V, A, W, VA, var, Hz, V, Avg. A cos phi, sin phi and phi measurement kwh, kvarh (via Pulse Output)
MODEL EM4000ACF Multifunction Transducer for alternating voltage and current Power supply voltages: Suitable for DIN-rail mounting 85 240Vac 400,440Vac 24 65Vdc 100..330Vdc V, A, W, VA, var, Hz, V, Avg.
More informationIncremental Shaft Encoders Industrial types
Synchro flange Universal industry standard encoder Up to 40 000 steps with 10 000 pulses High signal accuracy Protection class up to IP67 Operating temperature up to 100 C (RI 58-T) Flexible due to many
More informationPART NUMBERING SYSTEM
Plug-In Timer 11 pins Multifunction or monofunction Compact body for space saving Wide time range (from 0.5 seconds to 10 days delay) Universal power supply (12-240 Vz) 1 or 2 relay outputs (SPDT / Changeover)
More informationPhotoelectric switches WLL 170(T), fibre-optic cables LL 3: flexible solutions with fibre-optic cable systems
WLL 0(T) Photoelectric switches Photoelectric switches with fibre-optic cable Proximity mode Photoelectric switches with fibre-optic cable Through-beam mode Photoelectric switches WLL 0(T), fibre-optic
More informationLC2D09BL REVERSING CONTACTOR 575VAC 9A IEC
Product datasheet Characteristics LC2D09BL REVERSING CONTACTOR 575VAC 9A IEC Price* : 107.62 GBP Main Range Product name Product or component type Device short name Contactor application Utilisation category
More informationElectrical data Nominal voltage AC/DC 24 V Nominal voltage frequency
echnical data sheet LR24A-KNX Communicative rotary actuator for ball valves Nominal torque 5 Nm Nominal voltage AC/DC 24 V Conversion of sensor signals echnical data Electrical data Nominal voltage AC/DC
More informationAdd-on modules DX 3 63A for MCBs DX 3 1,5 modules per pole
87045 LIMOGES Cedex Telephone number: +33 (0)5 55 06 87 87 Fax: +33 (0)5 55 06 88 88 Add-on modules DX 3 63A for MCBs CONTENTS PAGE 1. Description, use... 1 2. Range... 1 3. Overall dimensions... 1 4.
More informationTemperature Input Module for Zone 1 Series 9482/32
www.stahl.de > 8 channels for temperature sensors > Intrinsically safe inputs Ex ia > For Pt-, Ni- and Cu-resistance temperature detectors according to DIN, IEC and GOST in 2-, 3- and 4-wire circuits >
More informationType CP-S, CP-C & CP-A Switch mode
Switch mode power CP-S, CP-C & CP-A Switch mode Characteristics CP-S and CP-C range Output current 5 A, 10 A and 20 A Integrated power reserve of up to 50 % 5 A and 10 A devices with pluggable connecting
More informationPulse Scaler for DIN Rail Attachment
Type 651 Pulse Scaler for DIN Rail Attachment Programmable pulse scaling factor up to 2047:1 NAMUR generator input PNP transistor output Max. pulse frequency 5 khz PROGRAMMING The divisor is set in binary
More informationSensors for Small Forces
Force Sensors for Small Forces 0,5... 0,5 N to 500... 500 N Type 9203, 9205, 9207, 9215A, 9217A These slim sensors are designed for dynamic and quasistatic tensile and compression forces. Depending on
More informationConnection targets. Universal sensors and switches, universal output devices
AnyWireASLK System Products Guide ASLKTERMAL [ASLK Small Terminal Block Terminal] BL296 B-08F EURO block type The Products Guide describes individual products. Refer to the Guide as necessary. Function
More informationMultiturn absolute encoder
SYNCHRON SERIELLES INTERFACE Multiturn absolute encoder Release date: 2016-07-12 16:14 Date of issue: 2016-07-12 t4917_eng.xml Model Number Features Industrial standard housing Ø58 mm 0 Bit multiturn Data
More informationBooster amplifier. Table of contents. Features. RE 30260/04.12 Replaces: Type VT-MSFA1. Component series 1X 1/6
Booster amplifier RE 30260/04.12 Replaces: 08.11 1/6 Type VT-MSFA1 Component series 1X H7924 Table of contents Contents Page Features 1 Ordering code 2 Functional description 2 Block diagram / pinout 3
More informationRE17LLBM asymmetrical flashing relay s V AC - solid state output
Characteristics asymmetrical flashing relay - 0.1..1 s - 24..240 V AC - solid state output Product availability : Non-Stock - Not normally stocked in distribution facility Price* : 75.00 USD Main Range
More informationRE17RAMU on-delay timing relay - 1 s..100 h V AC - 1 OC
Characteristics on-delay timing relay - 1 s..100 h - 24..240 V AC - 1 OC Complementary Contacts material Control type [Us] rated supply voltage Voltage range Main Range of product Product or component
More informationAnswering frequently asked Questions (Firmware V.107)
FAQ EasyConn Profibus plug Answering frequently asked Questions (Firmware V.107) EasyConn LEDs: While connected, the Profibus connector offers the following test functions for start-up and trouble shooting
More informationTECHNICAL DATASHEET Incremental Encoder RI 30
Miniature encoder for industrial use Low current consumption High noise interference immunity Cable lengths of up to 00 m Suitable for high pulse frequencies High protection class Applications: CNC machines,
More informationElectrical data Nominal voltage AC 230 V Nominal voltage frequency
echnical data sheet SY3-30-MP- Communicative rotary actuator for butterfly valves ominal torque 50 m ominal voltage Control modulating, communicative DC (0)...0 V Variable Position feedback DC...0 V Variable
More informationCableTroll 2410 PN: /03. User Manual
CableTroll 2410 PN: 01-2410- 02/03 User Manual UG CT 2410-RMU February 2010 This document describes the installation and configuration of the RMU Fault Indicator Product no: 01-2410- 02/03 Rev. 0.1 (21.01.09)
More informationAS-Interface Slaves. SIRIUS Pushbuttons and Indicator Lights. CustomAS-Interface enclosures 10/101
CustomAS-Interface enclosures Overview There are two types of custom solutions for AS-Interface: The front panel module and the SIRIUS 3SB3 enclosed stations. NC Contacts AS-Interface enclosure Ordering
More informationGFT1012 2/4 Channel Precise Slave Generator
Features Two Independent Delay Channels (Four channels available as an option) 1 ps Time Resolution < 5 ps RMS Jitter (Slave-to-Slave) < 6 ps / C Drift (Slave-to-slave) 1 Second Range Output Pulse Up to
More informationElectronic temperature switch with display Model TSD-30
Electrical temperature measurement Electronic temperature switch with display Model TSD-30 WIKA data sheet TE 67.03 Applications Machine tools Hydraulic power packs Coolant and lubrication systems Machine
More informationDatasheet - PROTECT-IE-02
Print - Create PDF - Create EXCEL file 20.04.2011-18:28:57h Datasheet - PROTECT-IE-02 Input expander / PROTECT-IE Input expander Input for up to 4 sensors per interface e.g.: magnetic safety switches type
More informationRE22R2MMU Multifunction Timer Relay - 24VDC/ V AC - 2 C/O
Product data sheet Characteristics RE22R2MMU Multifunction Timer Relay - 24VDC/24..240 V AC - 2 C/O Main Range of product Product or component type Discrete output type Device short name Nominal output
More informationBtdin RCD Add-on modules 63A for MCBs 1,5 modules per pole
Index Pages 1. Descripton... 2 2. Product range... 2 3. Overall dimensions... 2 4. Fixing Connection... 3 5. Generl characteristics... 4 6. Compliance - Approvals... 6 7. Curves... 7 8. Auxiliares and
More informationElectrical data Nominal voltage AC/DC 24 V Nominal voltage frequency
echnical data sheet LM24A-KNX Communicative damper actuator for adjusting dampers in technical building installations Nominal torque 5 Nm Nominal voltage AC/DC 24 V Conversion of sensor signals echnical
More informationProduct and Applications Description
Product and pplications Description Diagram The transmitter 230V wave UP 110 (Diagram ) is a flushmounted device with radio communication for the wireless operation of room functions. It is possible to
More informationIBV 100/EXE 100 Interpolation and Digitizing Electronics
Linear Encoders Angle Encoders IBV 1/EXE 1 Interpolation and Digitizing Electronics Rotary Encoders 3-D Touch Probes Position Display Units Numerical Controls HEIDENHAIN linear, rotary and angle encoders
More informationAdvanced Ladder Logic Full IEC Languages 25A for <1 24 VDC DC Switched
EXL6 OCS Datasheet for HE- EXL1E0, HE- EXL1E2, HE- EXL1E3, HE- EXL1E4, HE- EXL1E5, HE- EXL1E6 HEXT371C100, HEXT371C112, HEXT371C113, HEXT371C114, HEXT371C115, HEXT371C116 1. Specifications Required Power
More informationMultiturn absolute encoder
SYNCHRON SERIELLES INTERFACE Multiturn absolute encoder Model Number Features Industrial standard housing Ø58 mm 30 Bit multiturn Data transfer up to 2 MBaud Optically isolated RS 422 interface Recessed
More informationInductive Sensors Single or Dual Loop Detectors Type LD with teach-in
Inductive Sensors Single or Dual Loop Detectors Type LD with teach-in Single or Dual loop detector Automatically adjustment of detection level Manual sensitivity for compensations of variations Easy installation
More informationLOW POWER PLA SERIES. PLA Series Brief Profile. Interfaces. Electronic DC Loads
Electronic DC Loads LOW POWER PLA SERIES PLA Series Brief Profile The electronic loads of PLA series combine the classic design of large, easy-to-read displays with modern interfaces and a wide range of
More informationElectronic AC Load ZSAC Series. 400 W up to 21,000 W 260 V up to 440 V 3 A up to 100 A. Rev. 3.03
Electronic AC Load Series 400 W up to 21,000 W 260 V up to 440 V 3 A up to 100 A Rev. 3.03 Electronic AC Loads, Series Interface overview RS-232 USB GPIB LAN System bus Analog / Analog isolated X X Standard
More informationQuidoDuplex RS. Set for bi-directional transmission of 4 or 8 two-state signals over RS485 or RS June 2011 w w w. p a p o u c h.
Set for bi-directional transmission of 4 or 8 two-state signals over RS485 or RS232 7. June 2011 w w w. p a p o u c h. c o m Q uidoduplex RS Datasheet Created: 3/16/2006 Last update: 6/7/2011 8:57 AM Number
More informationValve amplifier for proportional pressure valves
Valve amplifier for proportional pressure valves Type VT-MRMA1-1 RE 30214 Edition: 2017-03 Replaces: 04.13 Component series 1X Analog, modular design Suitable for controlling a direct current motor-operated
More informationVFSC9 ELECTRONIC SPEED CONTROLLER. Mounting and operating instructions
ELECTRONIC SPEED CONTROLLER Mounting and operating instructions Table of contents SAFETY AND PRECAUTIONS 3 PRODUCT DESCRIPTION 4 ARTICLE CODES 4 INTENDED AREA OF USE 4 TECHNICAL DATA 4 STANDARDS 5 WIRING
More informationTechnical Data. General specifications. Rated operating distance s n 3 mm
0102 Model Number Features Direct mounting on standard actuators Compact and stable housing with terminal compartment connection Fixed setting EC-Type Examination Certificate TÜV99 ATEX 1479X Usable up
More informationPQ-Box 100 Network Analyzer for Low-, Medium- and High-Voltage Networks
GB Technical data Issue 06/2009 PQ-Box 100 Network Analyzer for Low-, Medium- and High-Voltage Networks Fault detection Evaluation of voltage quality according to EN50160 and IEC61000-2-2 Fault recorder
More informationController for the Implementation of a Central or Decentralized Electrohydraulic System
EFX 1624m Electronic Controller Programmed with Eaton CONTROL F(x) Software to IEC 61131-3 Standard 2nd CAN interface for gateway function according to SAE J1939 Supply voltage 10...32V DC Technical Data
More informationPortable equipment for insulation fault location for unearthed and earthed systems (IT and TN systems) to be used in conjunction with or without an
EDS309 Portable equipment for insulation fault location for unearthed and earthed systems (IT and TN systems) to be used in conjunction with or without an equipment for insulation fault location EDS309x_D00012_02_D_XXEN/11.2018
More informationOptical laser distance sensors. Dimensioned drawing
Dimensioned drawing en 02-2012/11 50112361 150 800mm 10-30 V DC We reserve the right to make changes DS_ODSL96BS800_en_50112361.fm Small laser light spot for measurements on small, structured or metallic
More informationRemote Sensor Amplifier Terminal
9 Remote Sensor Amplifier Terminal Plug-in Sensor Amplifiers with Direct CompoBus/S Terminal Connections 1 SRT1 models support only high-speed communications systems 1 4-point terminals expand to 8 points
More informationDigital Input Output Module 24 V for Ex n Zone 2 Series 9472/35
www.stahl.de > 16 channels can be adjusted in pairs as digital inputs or outputs > Suitable for NAMUR proximity switches, 3-wire PNP proximity switches, contacts and solenoid valves (24 V / 0.5 A). > Up
More informationVersaPoint I/O Module
GFK-2012A March 2010 Module provides two-input channels for measuring signals from standard thermocouples. It supports thirteen different thermocouples types. In addition, it accepts linear voltage inputs
More informationDigital Input Module NAMUR Ex i / I.S. Inputs, 16 Channels for Zone 1 / Div. 1 Series 9470/22
www.stahl.de > 16 channels for contacts and NAMUR proximity switches (EN 60947-5-6) > Intrinsically safe inputs Ex ia IIC > Galvanic separation between inputs and system > Open-circuit and short-circuit
More informationILA2E572PC1A0 integrated drive ILA with servo motor V - EtherCAT - indus connector
Characteristics integrated drive ILA with servo motor - 24..48 V - EtherCAT - indus connector Main Range of product Product or component type Device short name Motor type Number of motor poles 6 Network
More informationIndustrial Controls. SIRIUS 3R_1* in sizes S00/S0 to S12. Catalog Add-On IC 10 AO 2012 SIRIUS. Answers for industry.
Industrial Controls SIRIUS R_* in sizes S00/S0 to S Catalog Add-On IC 0 AO 0 SIRIUS Answers for industry. Controls Contactors and Contactor Assemblies for Switching Motors Price Groups PG B, H / Introduction
More informationSIEMOS PQ The Multi-Functional Power Quality Analyzer for Low and Medium-Voltage Networks
www.reinhausen.com SIEMOS PQ The Multi-Functional Power Quality Analyzer for Low and Medium-Voltage Networks SIEMOS PQ the power quality analyzer for every application The SIEMOS PQ three-phase network
More informationSIGMA F+E 3 Short-Circuit and Earth Fault Indicator
SIGMA F+E 3 Short-Circuit and Earth Fault Indicator Product Features Short-circuit and earth fault detection from only 3 single-phase current sensors Phase-selective fault indication and fault signalling
More informationRadiocontrol F. Floor Heating Controller Radio control system for floor heating
Radiocontrol F Floor Heating Controller Radio control system for floor heating IMI HEIMEIER / Floor Heating Control / Radiocontrol F Radiocontrol F The Radiocontrol F radio control system for controlling
More information22/10/2012
22.5 mm DIN rail mounting TUR1 Part number 88865105 Multi-function or mono-function Multi-range Multi-voltage Screw or spring terminals LED status indicator Option of connecting an external power supply
More informationIntelligent Drive Systems, Worldwide Services SK 700E F 3070 GB
Intelligent Drive Systems, Worldwide Services SK 700E Universal application Modular High-Performance Inverter NORDAC SK 700E The NORDAC SK 700E frequency inverter is designed for the power range between
More information400 W up to 21,000 W 260 V up to 440 V 3 A up to 100 A. Electronic Load ZSAC
400 W up to 21,000 W 260 V up to 440 V 3 A up to 100 A Electronic Load Electronic AC Loads, Interface overview RS-232 USB GPIB LAN System bus Analog X Analog isolated X Standard ption / not available 4226
More informationE Charge-controlled amplifier module
Technical Note E-506.10 Charge-controlled amplifier module Description... 1 Charge-controlled piezo operation... 1 Position servo-control operation... 1 CE conformity... 2 Safety notes... 3 Operating controls...
More informationDIGITAL LENGTH GAUGES
DIGITAL LENGTH GAUGES Series ST 12 / ST 30 Key-Features: Content: Mechanical Data...2 Electrical Data...2 Technical Drawing...3 Gauging Force / Path Diagram...4 Gauging Force / Pressure Diagram...4 Electrical
More informationFX-CM. HQ Color Mark Sensor. Model Number Legend SALIENT FEATURES. Sensors. Proximity. Photoelectric. Sensors
HQ Color Mark Sensor SALIENT FEATURES 18mm ±2mm Pushbutton Teach RGB LED light source 8 Remote Memory Setting Shock Resistant casing - 50G Model Number Legend 1 2 3 4 5 1. Series 4. Output FX 2. Type CM:
More informationElectronic Circuit Breaker ESS1 for System SVS1
Electronic Circuit Breaker ESS for System SVS Description The electronic circuit breaker ESS is designed to ensure selective disconnection of individual loads in industrial systems which are powered by
More information