1 Level and Pressure Operating Instruction VEGASEL max. min. on VEGASEL in out
2 Contents Contents Safety information Product description 1.1 Function and configuration Approvals Types and versions Technical data and dimensions Mounting and installation instructions Electrical connection 3.1 Wiring instruction Wiring plan Set-up 4.1 Indicating and operating elements Set-up sequence Switch point adjustment Diagnosis 5.1 Maintenance Repair Failure removal Safety information The described module must only be inserted and operated as described in this operating instruction. Please note that other action can cause damage for which VEGA does not take responsibility. 2 VEGASEL 643
3 Product description 1 Product description 1.1 Function and configuration VEGASEL 643 auxiliary level switch is a build-in instrument with terminal socket, suitable for carrier rail mounting (DIN ). Together with a sensor or a VEGAMET signal conditioning instrument it is used for level detection. Typical applications are two-point controls, e.g. pump controls (ON/OFF) and monitoring functions such as overfill protection and protection against dry running of pumps. The auxiliary level switch is provided with two passive inputs, a current and a voltage input as well as additionally with an active current input. Hence VEGASEL 643 can be connected for control either with a VEGAMET or a sensor (4 20 ma). Fig. 1.2 VEGASEL 643 with sensor on VEGASEL 643 max. min Sensor (4 20 ma) Function VEGASEL 643, controlled by a VEGAMET - The continuous current or voltage course of the VEGAMET signal processing instrument is processed into a switching command. In both cases a relay output is available for processing. Configuration With a VEGASEL 643 an available measuring system, consisting of sensor and VEGAMET signal conditioning instrument can be extended by a level detection. Or an own measuring system can be created with a 4 20 ma sensor. 100 % 0/4 20 ma 50 or 0 10 V max. min. 1.2 Approvals 0! on VEGAMET 602EX on VEGASEL If measuring systems are created according to the following approvals, the respective legal documents and their regulations have to be observed. These documents are supplied with the respective measuring system. Fig. 1.1 VEGASEL 643 on a VEGAMET p p WHG-approval, VbF-approval VEGASEL 643 auxiliary level switch together with a measuring system (sensor and VEGAMET) as part of an overfill protection acc. to WHG (test certificate applied) or acc. to the regulations for combustible liquids (test certificate applied). VEGASEL 643 with a 4 20 ma sensor - VEGASEL 643 auxiliary level switch powers via the active current input the sensors and processes its continuous 4 20 ma current signal into a switching command. CE-conformity see 1.4 Technical data. VEGASEL 643 3
4 Product description 1.3 Types and versions VEGASEL 643 Two-point auxiliary level switch with selectable mode; mode A (overfill protection) or mode B (protection against dry running of pumps) adjustable switching hysteresis Inputs: - passive current input 0/4 20 ma - active current input (connections of a sensor 4 20 ma) - passive voltage input 0/2 10 V Outputs: 1 relay (spdt) Approvals: as part of an overfill protection acc. to WHG and VbF Application: level detection, overfill protection, protection against dry running of pumps Max. Min. Level off on Time t Fig. 1.2 Two-point auxiliary level switch VEGASEL Technical data and dimensions General data Power supply Operating voltage Power consumption Fuse V AC, 50/60 Hz V DC max. 1,7 W (4,5 VA) T 1 A, 250 V Measuring data inputs Input 1 1 current input Kind of input active two-wire input analog Range 4 20 ma Application connection of sensors (4 20 ma) Sensor supply voltage V DC Switching threshold adjustable via coded key Min. hysteresis 1 % Current limitation appr. 25 ma, permanently shortcircuit proof Temperature error 0,05 %/10 K of range Switch point error 0,5 % of adjusted switch point Connection cable 2 wire (standard line) Resistor per conductor max. 35 Ω Interlock diode for connection of a measuring instrument max. load 15 Ω Input 2 1 additional current input Kind of input passive two-wire input analog Range 0/4 20 ma Inner resistor Ri = 50 Ω Application direct connection to active current output of e.g. VEGAMET 601, 602 Ex Switching threshold adjustable via coded key Min. hysteresis 1 % Temperature error 0,05 %/10 K of range Switch point error 0,5 % of adjusted switch point 4 VEGASEL 643
5 Product description Input 3 1 voltage input Kind of input passive two-wire input analog Range 0/2 10 V DC Inner resistor Ri 100 kω Application direct connection to active voltage output of e.g. VEGAMET 601, 602 Ex Switching threshold adjustable via coded key Min. hysteresis 1 % Temperature error 0,05 %/10 K of range Switch point error 0,5 % of adjusted switch point Connection cable 2-wire (standard line) Resistor per conductor max. 100 Ω Electrical connection Screw terminal max. 1,5 mm 2 Electrical protective measures Protection - instrument IP 30 - terminal socket IP 20 Protection II Overvoltage category II Mechanical data Series module instrument with terminal socket incl. transparent cover, cover of the sensor terminals, coded pin, two connection bridges Mounting carrier rail mounting acc. to DIN , Bl. 3 Dimensions unassembled W = 36 mm, H = 118,5 mm, D = 134 mm Weight appr. 170 g Ambient conditions Permissible ambient temperature Storage and transport temperature -20 C +60 C -40 C +70 C Relay output Number 1 output Contact 1 spdt (open 12-13, closed 12-14) AgCdO and Au plated Turn-on voltage min. 10 mv DC max. 250 V AC, 60 V DC Switching current min. 10 µa DC max. 2 A AC, 1 A DC Breaking capacity max. 125 VA, 54 W Indicating elements LED in front plate Functions Mode Adjustments of the inputs green on: operating voltage on yellow on: relay energized overfill protection (A) protection against dry running of pumps (B) 0 20 ma or 4 20 ma 0 10 V or 2 10 V VEGASEL 643 5
6 Product description Operating elements Front plate Laterally on top 2 coded key 0 99 % 1 DIL-switch for adjustment - mode A/B (overfill protection/protection against dry running of pumps) - adjustment possibility of the inputs 0 20 ma or 4 20 ma 0 10 V or 2 10 V Electrical separating measures Reliable separation acc. to VDE 0106, part 1 - limit voltage 250 V - isolation resistance 3 kv between power supply, meas. data inputs and level relais CE-conformity VEGASEL signal conditioning instruments meet the protective regulations of EMVG (89/336/EWG) and NSR (73/23/EWG). The conformity has been judged acc. to the following standards: EMVG Emission EN Immission EN NSR EN Carrier rail 35 x 7,5 or 35 x 15 acc. to EN Transparent cover 54,5 118,5 VEGA VEGASEL 643
7 Mounting and installation instructions 2 Mounting and installation instructions Mounting Each series 600 signal conditioning instrument consists of a terminal socket for carrier rail mounting DIN and a module instrument. The supply voltage can be connected to terminals 9 and 10. For neighbouring series 600 signal conditioning instruments it is possible to provide and loop the connection L1 and N directly via the supplied bridges. The same is valid for the connection VEGAMETvoltage output 0 10 V to VEGASEL-voltage input 0 10 V /terminals 7 and 8). Coding The terminal socket must be provided with pins and the signal conditioning instrument with appropriate gaps (mechanical coding) to avoid interchanging of the individual signal conditioning instruments. An instrument coding ensures that interchanging among the signal conditioning instruments is avoided by differently positioned coded keys. Note, danger! Never use the bridges with single instrument or at the end of an instrument row. They may come in touch with the operating voltage or cause a shortcircuit. Instrument coding VEGASEL 643 (pin 4) Direct connection for voltage input 0 10 V Direct connection for supply voltage A o B o C o 1 o 2 o 3 o o o o 7 o 8 o 9 o o o o 0 10 V N L1 VEGA VEGASEL 643 7
8 Electrical connection 3 Electrical connection 3.1 Wiring instruction The following wiring plan and the extension examples 1 and 2 are valid for standard as well as for Ex-versions of the signal conditioning instruments. Please note the following instructions: - the relay contact is shown in unpressurized condition - if strong electromagnetic interferences are expected, we recommend to use screened cable for the signal lines - the screening must only be earthed at one sensor side - in case of overvoltages we recommend the use of VEGA-overvoltage arresters - the connection must be made according to the appropriate national installation standards (e.g. in Germany according to VDE-regulations). 3.2 Wiring plan Sensor + + VEGASEL 643 active current input for connection of a sensor (4 20 ma) passive current input for connection of a signal conditioning instrument (VEGAMET ) 10 V passive voltage input for connection to the voltage output of a signal conditioning instrument (VEGAMET ) 9 10 L1 N Relay output Supply voltage 8 VEGASEL 643
9 Electrical connection Extension example 1 Instrument 1: VEGASEL 643 actively switched Instrument 2 up to max. instrument 5: VEGASEL 643 passively switched Note: The voltage inputs (7, 8) must not be used when the current inputs are switched. Sensor (4 20 ma) active passive + + Current + + Current + + inputs inputs passive Current inputs VEGASEL VEGASEL VEGASEL Instrument 1 Instrument 2... up to max.. instrument 5 Extension example 2 Instrument 1: VEGAMET 601 or 602 Ex Instrument 2 up to max. instrument 10: VEGASEL 643 each switched to passive voltage input (parallel switching) Note: Current inputs (3, 4) must not be used when the voltage inputs are switched. Sensor V VEGAMET + Voltage input 10 V + 10 V + Voltage input VEGASEL VEGASEL Voltage input Instrument 1 Instrument 2... up to max.. instrument 10 According to the extension examples it is possible to control several signal conditioning instruments with one sensor and hence to detect different levels. This kind of switching can be extended each up to 5 or 10 instruments. VEGASEL 643 9
10 Set-up 4 Set-up 4.1 Indicating and operating elements max. min Key for value falling 2 Coded key for max. switch point 3 Key for value raising 4 Coded key for min. switch point 5 Status indication of the output 6 LED-supply voltage 7 Separating wall 8 Terminals current input 9 Terminals voltage input 10 Terminals supply and relay output 5 6 on VEGASEL Top view, laterally Bar code, series number 12 DIL-switch block 13 Screws 14 Ventilation opening 15 Transparent cover VEGASEL 643
11 Set-up Coded key Coded keys (2 and 4) are located in the front plate by which the switch point (with single point level switches) as well as the switching hysteresis (with double point level switches) can be adjusted. The figures are given in % and relate to the current or voltage input. By pushing the buttons + or you can adjust the requested values raising or falling in 1 % or 10 %-steps. Signal lamps Green (6) - Supply voltage on, ready for operation Yellow (5) - Status indication of the relay output (LED lights = relay energized, LED extinguished = relay de-energized) DIL-switch (13) Laterally on top. When the signal conditioning instrument is mounted, covered by the terminal socket. Description of the individual functions Mount the terminal socket. Wire the input terminals of the terminal socket acc. to the above mentioned conditions. Cover the input terminals with the separating chamber. Switch the output of the auxiliary level switch acc. to the technical requirements. Adjust on the DIL-switch (11) the range of the inputs. When connecting a sensor to the active current input (terminals 1 and 2) set the DIL-switch to 4 20 ma. Select on the DIL-switch (11) the desired mode. Adjust the switch points acc. to section 4.3. Mount the module unit to the terminal socket. Switch on the supply voltage, the green LED (6) lights. 4.3 Switch point adjustment Single point control With a single point control it is possible to generate at one point of the input signal (0 10 V or 0/4 20 ma) a switching signal. Coded key 0.. B 2..10V 4..20mA A % /80 max. 80 min. 79 Hysteresis 1 % Adjustment possibility - Current input 0 20 ma or 4 20 ma voltage output 0 10 V or 2 10 V - Mode A or B A = overfill protection, B = protection against dry running of pumps Mode A Mode B 0 t Set-up sequence The following list states the essential set-up steps in short Pre-requirement: VEGASEL 643 auxiliary level switch is connected with a measuring system (sensor and VEGAMET ) or directly with a sensor (4 20 ma). Procedure Adjust the switch point on both coded keys. As example min. = 79 %, max. = 80 %, with this adjustment there is a hysteresis of 1 %. Possible adjustment range 1 % 99 %. The auxiliary level switch is hence ready for operation. Please cover with the transparent cover (15). VEGASEL
12 Set-up Double point control With a double point control it is possible to generate switching signals at two different points of the input signal (0/2 10 V or 0/4 20 ma). Example 2 - Voltage input 2 10 V - Two-point control - Switch points min. = 20 %, max. = 60 % Procedure Mode A Mode B % Coded key max. 60 ^ Hysteresis 40 % min. 20 t V corresponds to 0 % 100 %, = 10 V 2 V = 8 V 20 % of 8 V = 1,6 V 60 % of 80 V = 4,8 V Switch point 20 % corresponds to 1,6 V + 2 V = 3,6 V Switch point 60 % corresponds to 4.8 V + 2 V = 6,8 V Example 3 - Current input 0 20 ma - Two-point control - Switch points min. = 20 %, max. = 60 % 0 20 ma corresponds to 0 % 100 %, = 20 ma Adjust the coded key with different values. Possible adjustment range 1 % 99 %. As example min. = 20 %, max. = 60 %, with this adjustment there is a hysteresis of 40 %. The auxiliary level switch is hence ready for operation. Please cover with the transparent cover (15). Note: Adjust the percentage values with the coded keys which relate to the input signal. Example 1 - Voltage input 0 10 V - Two-point control - Switch points min. = 20 %, max. = 60 % 0 10 V corresponds to 0 % 100 %, = 10 V 20 % of 10 V = 2 V 60 % of 10 V = 6 V Switch point 20 % corresponds to 2 V Switch point 60 % corresponds to 6 V 20 % of 20 ma = 4 ma 60 % of 20 ma = 12 ma Switch point 20 % corresponds to 4 ma Switch point 60 % corresponds to 12 ma Example 4 - Current input 4 20 ma - Two-point control - Switch points min. = 20 %, max. = 60 % 4 20 ma corresponds to 0 % 100 %, = 20 ma 4 ma = 16 ma 20 % of 16 ma = 3,2 ma 60 % of 16 ma = 9,6 ma Switch point 20 % corresponds to 3,2 ma + 4 ma = 7,2 ma Switch point 60 % corresponds to 9,6 ma + 4 ma = 13,6 ma The calculation and information examples are valid in the same way for the single point control. 12 VEGASEL 643
13 Diagnosis 5 Diagnosis 5.1 Maintenance The instrument is maintenancefree. 5.2 Repair For safety and guarantee reasons repairs on the instrument must only be carried out by VEGA-staff. In case of a defect please return the respective instrument along with a short description of the fault to our repair department. Occurring faults, possible reasons and their removals are stated under 5.3 Failure removal. 5.3 Failure removal Failure Instrument does not function, the green mains control lamp extinguishes Instrument does not switch correctly Instrument does not switch when using the active input Removal / Measure Check the supply voltage and the mains connection by means of the Connection instructions. When the instrument still does not function, contact our service department. Check the position of the coded keys. The switch points for min. and max. must not be set to the same values. Correct if necessary the values. Check the connected measuring data input - Check wiring, see 3.3 Wiring plan and extension examples - Check voltage or current values on their nominal range, see 1.4 Technical data. - The auxiliary level switch is internally provided with an interlock diode. A measuring instrument connected to terminal 2 and 3 is hence automatically switched into the circuit of the measuring line (switching in series). Hence it is possible to check the measuring line. The measuring instrument indicates the actual current. ma Load of the measuring instrument max. 15 Ω VEGASEL
14 Notes 14 VEGASEL 643
15 Notes VEGASEL
16 VEGA Grieshaber KG Am Hohenstein 113 D Schiltach Phone ( ) 50-0 Fax ( ) Fax ( ) ISO 9001 Technical data subject to alterations / Sept. 1996
Operating Instructions
Level and Pressure Operating Instructions VEGATOR 620, 621, 622 max. 0 10 min. 0 10 on VEGATOR 622! 6 7 8 9 10 11 12 13 14 in out Contents Contents Safety information... 2 Note Ex area... 2 1 Product description
More informationOperating Instruction
Level and Pressure Operating Instruction VEGAVIB and signal conditioning instruments Contents Contents Safety information... 1 Product description 1.1 Function and configuration... 3 1. Types and versions...
More informationLevel and Pressure. Product Information. Vibrating level switches
Level and Pressure Product Information Vibrating level switches Contents Contents 1 Product description 1.1 VEGAVIB... 3 1.2 VEGASWING... 3 2 Function and application 2.1 Functional principle... 5 2.2
More informationLevel and Pressure. Product Information. Conductive level detection
Level and Pressure Product Information Conductive level detection Contents Contents 1 Product description 1.1 Application... 1. Function... 5 1. Types/Versions... 6 1.4 Application examples... 8 1.5 Adjustment...
More informationLevel Limit Switch nivotester FTL 325 P
Technical Information TI 350F/24/ae Level Limit Switch nivotester FTL 325 P With intrinsically safe signal circuit for connection to the Liquiphant and Soliphant measuring sensor Application Level limit
More informationTrip amplifier, 1 channel
Trip amplifier, channel Features I II III + + P I out I U out 4 Relay overrange Relay overrange Relay overrange ç 4...0 ma IM4-4-SRi: è 0...0 ma IV + + + > 50 kw 5 6 7 8 9»8 V < 5 ma 50 W Pwr GN/RD 4 5
More informationOperating Instruction
Level and Pressure Operating Instruction Capacitive electrodes EK with signal conditioning instrument Safety information Safety information The described module must only be installed and operated as described
More informationOperating Instructions
Level and Pressure Operating Instructions VEGAMET 515-100 + ESC OK CONNECT CONNECT 1 2 1 2 on on in out Contents Contents 1 Product description 1.1 Function and configuration... 4 1.2 Approvals... 5 1.3
More informationXR1 Rotor Earth Fault Relay. (May 2007) Manual XR1 (Revision New)
XR1 Rotor Earth Fault Relay (May 2007) Manual XR1 (Revision New) Woodward Manual XR1 GB Woodward Governor Company reserves the right to update any portion of this publication at any time. Information provided
More informationLevel Limit Switch nivotester FTL 370, FTL 372
Technical Information TI 98F/00/en Limit Switch nivotester FTL 370, FTL 37 With intrinsically-safe signal circuits for connection to sensors Liquiphant, Nivopuls, Soliphant. Features at a Glance High operational
More informationXR1 Rotor Earth Fault Relay. Manual XR1 (Revision C)
XR1 Rotor Earth Fault Relay Manual XR1 (Revision C) Woodward Manual XR1 (EN) Woodward Governor Company reserves the right to update any portion of this publication at any time. Information provided by
More informationCurrent consumption ma solenoid current consumption ( max 300 ma) Hz % V ma. Housing dimensions mm 120(d) x 99(h) x 23(w)
89 610/112 ED EWM-A-SV ANALOG AMPLIFIER CARD SERVOVALVE CONTROL RAIL MOUNTING TYPE: DIN EN 50022 OPERATING PRINCIPLE This card is designed for a dynamic control of servovalves with the current output controlled
More informationMINI MCR-SL-UI-I-LP-NC
2-way isolation amplifier Data sheet 105263_en_02 PHOENIX CONTACT 2013-12-13 1 Description The configurable 2-way isolation amplifiers are used to electrically isolate, convert and filter standard signals.
More informationLiquid level monitoring relay CM-ENS.2x
Data sheet Liquid level monitoring relay CM-ENS.2x The CM-ENS.2x is served to regulate and control liquid levels and ratios of mixtures of conductive fluids. It can be used for overflow protection, dry
More informationThree-phase monitoring relay CM-PFS
Data sheet Three-phase monitoring relay CM-PFS The CM-PFS is a three-phase monitoring relay that is used to monitor three phase mains for incorrect phase sequence and phase failure. All devices are available
More informationElectronic amplifier for the control of proportional valves without position control Model VT 3006, Series 3X H/A 4240/94 VT X
Electronic amplifier for the control of proportional valves without position control Model T 3006, Series 3X RA 29 926/06.98 Replaces: 02.96 The amplifier T 3006-3X is suitable for the control of pilot
More informationISOMETER IRDH575. Approvals
Insulation monitoring device for unearthed AC, DC and AC/DC systems (IT systems) with control and display function for EDS insulation fault location systems IRDH575_D00089_02_D_XXEN/09.2018 Insulation
More informationSINEAX B 811 Power Pack with additional Functions
SINEA B 8 for intelligent and conventional s, in housing S7 for rail and wall mounting 002 II () G Application The power supply unit SINEA B 8 (Figure ) provides the DC power supply for s and transfers
More informationXUA1 - AC Voltage and phase balance relay
XUA1 - AC Voltage and phase balance relay Contents 1. Applications and features 2. Design 3. Function 3.1 Voltage supervision 3.2 Unbalanced voltage supervision 4. Operation and settings 4.1 Setting of
More informationLevel detection in liquid. Conductive. VEGAKON 61 VEGAKON 66 Probes EL 1, 3, 4, 6, 8. Product Information
Level detection in liquid Conductive VEGAKON 6 VEGAKON 66 Probes EL,, 4, 6, 8 Product Information Content Content Description of the measuring principle...........................................................
More informationValve amplifier for proportional valves with electrical position feedback
Valve amplifier for proportional valves with electrical position feedback Type VT-MRPA1-... RE 30221 Edition: 2015-02 Replaces: 2013-08 Component series 1X Analog, modular design Intended for controlling
More informationRMA42. Technical Information
Technical Information RMA42 Process transmitter with control unit Digital process transmitter for mounting on a top-hat rail for monitoring and visualizing analog measured values Application Plant and
More informationAnalog amplifier. RE 29926/10.06 Replaces: Type VT Component Series 3X
Analog amplifier RE 29926/10.06 Replaces: 0.03 /8 Type VT 3006 Component Series 3X H4240_d Table of contents Contents Page eatures 1 Ordering code 2 unctional Description 2 and 3 Block circuit / pin allocation
More informationTVA 080 / 100 / 120 / 180 / 200 / 220 Isolation amplifier active
Technical manual BA 0318 Signal converter Isolation amplifier active for galvanic isolation, conversion and adjustment of electrical standard signals Evaluable input signals Direct voltage 0...10V / 0...1V
More informationSIMEAS-T. Operating Instructions Transducer without auxiliary power. 7KG6111 and 7KG6101. Operating Instructions
Operating Instructions SIMEAS-T s Operating Instructions Transducer without auxiliary power for alternating current for alternating voltage for alternating voltage with expanded end range 7KG6111 and 7KG6101
More informationOperating Instructions / Voltage Tester per IEC with Phase and Polarity Tester and Phase Sequence Indicator
Operating Instructions 3-349-298-15 3/11.09 METRAVOLT 7A Voltage Tester per IEC 61243-3 with Phase and Polarity Tester and Phase Sequence Indicator CAT IV GMC-I Messtechnik GmbH Südwestpark 15 90449 Nürnberg
More informationElectronic relays. Monitoring. Monitoring
Electronic relays Neither overload nor underload are particularly good for machines and installations in industrial applications. An unsteady power supply may lead to machine failure and, thus, expensive
More informationInsulation monitoring relay CM-IWS.1 For unearthed AC, DC and mixed AC/DC systems up to U n = 250 V AC and 300 V DC
Data sheet Insulation monitoring relay CM-IWS.1 For unearthed AC, DC and mixed AC/DC systems up to U n = 250 V AC and 300 V DC The CM-IWS.1 serves to monitor insulation resistance in accordance with IEC
More informationCurrent monitoring relays CM-SRS.1 For single-phase AC/DC currents
Data sheet Current monitoring relays CM-SRS.1 For single-phase AC/DC currents The CM-SRS.1 is an electronic current monitoring relay that protects single-phase mains (DC or AC) from over- and undercurrent
More informationElectronic Measuring Relays for Current, Voltage and Overfrequency
Electronic easuring Relays for Current, Voltage and Overfrequency AE Catalog Edition. info@klaschka.de Electronic easuring Relays Contents and housing data 0 ntroduction 0.0. Contents, basics 0.0., housing
More informationXUA1 AC Voltage and phase balance relay. (August 1996) Manual XUA1 (Revision New)
XUA1 AC Voltage and phase balance relay (August 1996) Manual XUA1 (Revision New) Woodward Manual XUA1 GB Woodward Governor Company reserves the right to update any portion of this publication at any time.
More informationRemote Switching Unit nivotester FTL 320
Technical Information TI 203F/24/ae Remote Switching Unit nivotester For connection to intrinsically safe Liquiphant level limit switches Applications Limit detection of fluids and bulk solids in tanks
More informationV2UM230V10 Art.Nr.: V2UM230V10P Art.Nr.: Control elements. Tripping delay. Function selector. Status indication 230 V AC/DC
P AC/DC voltage monitoring Multifunction Supply voltage 24 V DC or 230V AC/DC Supply circuit = Measuring circuit 1 change-over contact Width 22,5 mm Control elements Tripping delay Maximum threshold Minimum
More informationCurrent monitoring relays CM-SRS.2 For single-phase AC/DC currents
Data sheet Current monitoring relays CM-SRS.2 For single-phase AC/DC currents The CM-SRS.2 is an electronic current monitoring relay that protects single-phase mains (DC or AC) from over- and undercurrent
More informationVEO. V2PF480Y/277VSY01 Art.Nr.: V2PF480Y/277VSY01P Art.Nr.: TECHNICAL DATA
P Monitoring of phase sequence and phase loss Monitoring of asymmetry Supply voltage 208-480 V AC Supply circuit = measuring circuit 1 change-over contact Width 22,5 mm Control elements Asymmetry Status
More informationValve amplifier for proportional pressure valves
Valve amplifier for proportional pressure valves Type VT-MRMA1-1 RE 30214 Edition: 2017-03 Replaces: 04.13 Component series 1X Analog, modular design Suitable for controlling a direct current motor-operated
More informationVoltage monitoring relay CM-EFS.2 For single-phase AC/DC voltages
Data sheet Voltage monitoring relay CM-EFS.2 For single-phase AC/DC voltages The CM-EFS.2 is an electronic voltage monitoring relay that provides reliable monitoring of voltages as well as detection of
More informationEMD-FL-C-10. Current Monitoring Relay. Data Sheet. Functions. Structure 08/2004
Current Monitoring Relay Data Sheet 08/2004 Functions Structure Current monitoring of direct and alternating current in 1-phase networks with settable threshold values, starting override and response delay
More informationElectronic Amplifier Model VT 3017 and VT 3018 (Series 3X) for the control of proportional directional valves, without positional feedback
RA 29 939/06.98 Electronic Amplifier Model T 301 and T 3018 (Series 3X) for the control of proportional directional valves, without positional feedback RA 29 939/06.98 Replaces: 09.94 Electronic amplifier
More informationMoeller Electric Corporation
EMR4-I Current Monitoring Relays 02/0053 EMR4-I1-2-A EMR4-I15-2-A EMR4-I15-2-B Mechanical lifespan operations x10 6 30 30 30 24-h cycle, 55 C, 93 % relative humidty, 96 h Ambient temperature min./max.
More informationVEO. V2PF480Y/277VS01 Art.Nr.: B TECHNICAL DATA
Monitoring of phase sequence and phase loss Monitoring of asymmetry Supply voltage 208-480 V AC Supply circuit = measuring circuit 1 change-over contact Width 22,5 mm Status indication LED U: Supply voltage
More informationCoupling Relays and Converters
Overview Area of application In automation and control engineering it will always be necessary to work with analog signals. The interfaces for analog signals that have established themselves as the standard
More informationTemperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection)
Data sheet Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection) The temperature monitoring relays CM-TCS monitor overtemperature,
More informationISOMETER iso685- -B. Insulation monitoring device for unearthed AC, AC/DC and DC systems (IT systems) Preliminary data sheet
Insulation monitoring device for unearthed AC, AC/DC and DC systems (IT systems) Preliminary data sheet iso685-x-b_d00177_04_d_xxen/04.2018 Insulation monitoring device for unearthed AC, AC/DC and DC systems
More informationVoltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages
Data sheet Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages The CM-ESS.2 is an electronic voltage monitoring relay that provides reliable monitoring of voltages as well as detection of
More informationElectronic Air / Fuel Ratio Control System
7 871 ISO 9001 Electronic Air / Fuel Ratio Control System RVW20... Electronic control unit - for use with modulating single- and dual-fuel burners - with extended functionality for mechanical air / fuel
More informationType CP-S, CP-C & CP-A Switch mode
Switch mode power CP-S, CP-C & CP-A Switch mode Characteristics CP-S and CP-C range Output current 5 A, 10 A and 20 A Integrated power reserve of up to 50 % 5 A and 10 A devices with pluggable connecting
More informationTRANSDUCER of TEMPERATURE and STANDARD SIGNALS P20 type
TRANSDUCER of TEMPERATURE and STANDARD SIGNALS P20 type USER S MANUAL Contents 1. APPLICATION...5 2. TRANSDUCER SET...5 3. OPERATIONAL SAFETY...6 4. INSTALLATION...7 4.1. Fitting way...7 4.2. External
More information02/11/2015
Standstill monitoring KSW3-JS Part number 85102331 Function "Stillstand detection without sensors" Independent of rotation direction Security with redundancy and feedback circuit 3 forcibly guided "NO"
More informationEMD-FL-3V Phase Voltage Monitoring Relay INTERFACE. Data Sheet. Description
3-Phase Voltage Monitoring Relay INTERFACE Data Sheet PHOENIX CONTACT - 03/2006 Description Voltage monitoring in 3-phase networks with settable threshold values, settable response delay, monitoring of
More information02/11/2015
Two-hand safety relays KZH3-YS Part number 85102632 "Two-hand" safety function in with two push buttons Inputs for two switches with double contacts (1 NO and 1 NC for each) Security with redundancy and
More informationCatalog 200 Contactors up to 115 A Motor Starters up to 55 kw 03/2009
Catalog 00 Contactors up to 5 A Motor Starters up to 55 kw 03/009 Kraus & Naimer The development of the Blue Line rotary switch, contactor and motor starter product ranges is based on more than hundred
More informationPTC-resistor relay type MS 220 K and MSR 220 K PTC-resistor trip device
MINIPAN digital panel meters, temperature- and mains controlling, special purpose instruments for customer requirements www.ziehl.com Operating manual PTC-resistor relay type MS 220 K and MSR 220 K PTC-resistor
More informationThermistor motor protection relays
Thermistor motor protection relays Content Benefits and advantages... / 68 Selection table... / 68 Ordering details CM-MSE... / 69 CM-MSS... / 69 CM-MSN... / 7 PTC sensor C0... / 7 Technical data... /
More information21 VA (l max 20 5 ms) Connection Cable 1 m, 4 x 0.75 mm 2 Functional data Factory settings Variable Setting Torque Inhibiting torque
echnical data sheet GK4A- Communicative SuperCap rotary actuator with emergency setting function and extended functionalities for adjusting air dampers in ventilation and air-conditioning systems for building
More informationUSER S MANUAL POWER SUPPLY - ISOLATOR - SIGNAL CONVERTER ZSP 41 POWER SUPPLY - ISOLATOR - SIGNAL CONVERTER SIGNAL MULTIPLIER ZSP 41/2
(ENG) DECEMBER 2017 USER S MANUAL POWER SUPPLY - ISOLATOR - SIGNAL CONVERTER ZSP 41 POWER SUPPLY - ISOLATOR - SIGNAL CONVERTER SIGNAL MULTIPLIER ZSP 41/2 ISOLATOR - SIGNAL CONVERTER TYPE SP 11 CURRENT
More informationHigh Voltage Power Supplies HCE - Series
High Voltage Power Supplies HCE - Series power class 7W and 35W certified according to DIN EN ISO 9001 Operating Instructions This instruction is only dedicated to electrical experts and people with a
More informationMCR-SL-CUC Universal current transducer. Data sheet _en_05. 1 Description
Universal current transducer Data sheet 104059_en_05 PHOENIX CONTACT 2011-03-09 1 Description MCR-SL-CUC-...-I and MCR-SL-CUC-...-U active current transducers convert DC, AC, and distorted currents into
More informationISOMETER iso685- Insulation monitoring device for unearthed AC, AC/DC and DC systems (IT systems)
Insulation monitoring device for unearthed AC, AC/DC and DC systems (IT systems) iso685-x_d00022_08_d_xxen/04.2018 Insulation monitoring device for unearthed AC, AC/DC and DC systems (IT systems) Product
More information650 PHOENIX CONTACT Courtesy of Power/mation Energy Lane, Saint Paul, MN
650 PHOENIX CONTACT Monitoring relays, timer relays, function blocks The requirements pertaining to safety and system availability are constantly increasing regardless of the industry. Processes are becoming
More informationMBS AG. KBR 18 Split-core current transformer. Further information about our new split-core current transformer KBR 18: Dimensions:
KBR 18 Split-core current transformer Dimensions: Round conductor: 18 mm Transformer width: 41.6 mm Transformer height: 64.5 mm Transformer depth incl. fixing clasps: 67.3 mm General technical specifications:
More informationLINAX 4000L Continuous-line recorder
-48-852-0 4/2.99 1 to 4 line channels Format 144 mm x 144 mm, mounting depth 250 mm Combined recording table for roll chart (2 m) or fanfold chart (16 m) Measuring channels electrically isolated Rugged
More informationMODEL: M2MNV MODEL: M2MNV-[1][2]-[3][4]
MODEL: MMNV Super-mini Signal Conditioners Mini-M Series ANALOG SWITCHING MODULE Functions & Features Switches between two analog signal channels Switches/Distributes one voltage signal to two channels
More informationInstallation and Operational Instructions for ROBA -multiswitch Type 019._00.2
Guidelines on the Declaration of Conformity A conformity evaluation has been carried out for the product in terms of the EU Low Voltage Directive 2014/35/ EU and the Electromagnetic Compatibility (EMC)
More informationInstallation and Operational Instructions for ROBA -switch Type 017._00.2
OBA -switch Type 017._00.2 Guidelines on the Declaration of Conformity A conformity evaluation has been carried out for the product in terms of the EC Low Voltage Directive 2014/35/ EC and the EMC Directive
More informationXP2-R Power and reverse power relay. (January 2006) Manual XP2-R (Revision New)
XP2-R Power and reverse power relay (January 2006) Manual XP2-R (Revision New) Woodward Manual XP2-R GB Woodward Governor Company reserves the right to update any portion of this publication at any time.
More informationElectronic timer CT-AHS.22 OFF-delayed with 2 c/o (SPDT) contacts
Data sheet Electronic timer CT-AHS.22 OFF-delayed with 2 c/o (SPDT) contacts The CT-AHS.22 is an electronic timer from the CT-S range with OFF-delay and 10 time ranges. All electronic timers from the CT-S
More informationElectronic timer CT-MVS.23 Multifunctional with 2 c/o (SPDT) contacts
Data sheet Electronic timer CT-MVS.23 Multifunctional with 2 c/o (SPDT) contacts The CT-MVS.23 is a multifunctional electronic timer from the CT-S range. It provides 11 timing functions and 10 time ranges.
More informationValve amplifier for proportional valves. Type VT-MSPA2-1. Contents. Features. RE Edition: Replaces:
Valve amplifier for proportional valves Type VT-MSPA2-1 RE 30228 Edition: 2014-01 Replaces: 2011-04 Component series 1X Suitable for controlling direct operated proportional directional valves without
More informationElectronic measuring and monitoring relays CM-range
Electronic measuring and CM-range Content Benefits and advantages CM range, function overview... 30 Selection and ordering details Current and voltage monitors, single phase... 33 Three phase monitors...
More informationOperating Instructions. Indication and adjustment module PLICSCOM
Operating Instructions Indication and adjustment module PLICSCOM 8888 Contents Contents 1 About this document... 4 1.1 Function... 4 1.2 Target group... 4 1.3 Symbolism used... 4 2 For your safety... 6
More informationDT1100 xx xx xx PS. Isolators, Isolator / Power Supplies. Operating Instructions
Isolators, Isolator / Power Supplies Operating Instructions EN Contents 1. About this document...4 1.1. Function... 4 1.2. Target group... 4 1.3. Symbolism used... 4 2. For your safety...5 2.1. Authorized
More informationDigital Input Output Module 24 V for Ex n Zone 2 Series 9472/35
www.stahl.de > 16 channels can be adjusted in pairs as digital inputs or outputs > Suitable for NAMUR proximity switches, 3-wire PNP proximity switches, contacts and solenoid valves (24 V / 0.5 A). > Up
More informationXU2-AC AC voltage relay. (Februar 1997) Manual XU2-AC (Revision New)
XU2-AC AC voltage relay (Februar 1997) Manual XU2-AC (Revision New) Woodward Manual XU2-AC GB Woodward Governor Company reserves the right to update any portion of this publication at any time. Information
More informationNSD Safety Mat Controller Modules Both Modules are compliant to OSHA & ANSI Standards - EN ISO EN EN 81-1 EN NSD VDC
Datasheet NSD Safety Mat Controller Modules Both Modules are compliant to OSHA & ANSI Standards - EN ISO 13849-1 EN 62061 EN 81-1 EN 50156-1 Approvals NSD-3580 24 VDC NSD-3590 115 TO 230 VAC Technical
More informationPressure measurement. Process pressure/hydrostatic VEGAWELL 72. Product Information
Pressure measurement Process pressure/hydrostatic VEGAWELL 7 Product Information Content Content Description of the measuring principle........................................................... Type overview..............................................................................
More informationP RODUCT C ATALOGUE 1/2002
S a f e t y R e l a y s S e r i e s U E 1 0-4 8 P RODUCT C ATALOGUE 1/2002 For technical details please unfold 2 SICK Industrial Safety Systems Germany All rights reserved 8 009 607/30-03-02 UE 10 UE 48
More informationThree-phase monitoring relays CM-PFE and CM-PFE.2
Data sheet Three-phase monitoring relays CM-PFE and CM-PFE.2 The CM-PFE is a three-phase monitoring relay that monitors the phase parameter phase sequence and phase failure in three-phase mains. 2CDC 251
More informationExtract from the online catalog
Please note that the data given here has been taken from the online catalog. For comprehensive information and data, please refer to the user documentation at http://www.download.phoenixcontact.com. The
More informationDT1100 E xx xx (PS) Galvanic Isolators. Operating Instructions
DT1100 E xx xx (PS) Galvanic Isolators Operating Instructions Contents 1. About this document...4 1.1. Function... 4 1.2. Target group... 4 1.3. Symbolism used... 4 2. For your safety...5 2.1. Authorized
More informationFor non-electrical quantities
Controlgear 3UG3 monitoring relays 3RS17 interface converters N nsb0346h nsb0348h nsb0775h For electrical quantities For non-electrical quantities 3RS17 interface converter Selection and ordering data
More informationCM-MPS.11, CM-MPS-21, CM-MPS.31 and CM-MPS.41 Data sheet. UL 508, CAN/CSA C22.2 No.14 GL GOST CB scheme CCC
2CDC 251 048 F0t08 CM-MPS.11 2CDC 251 049 F0t08 CM-MPS.21 Features Monitoring of three-phase mains for phase sequence (can be switched off), phase failure, over- and undervoltage as well as phase unbalance
More informationRISH Ducer TV 808, 2 channels Isolating amplifier unipolar / bipolar
Fig. 1. Isolating amplifier RISH Ducer TV 808 in housing S 17 clipped onto a top - hat rail or screw hole mounting brackets pulled out. Features and Benefits Electric Isolation between input, and power
More informationThree-phase monitoring relays
2CDC 251 046 F0t08 Features Monitoring of three-phase mains for phase sequence, phase failure, phase unbalance Threshold value for phase unbalance adjustable as absolute value Tripping delay can be adjusted
More informationAssembly. Front view. LED yellow: Relay output. LED red: LB/SC
Switch Amplifier Features Assembly -channel isolated barrier 30 V AC supply Dry contact or NAMUR inputs Relay contact output Line fault detection (LFD) Reversible mode of operation Up to SIL acc. to IEC
More informationKSR-Level sensor KSR-Schwimmer-Magnetschalter KSR Contact Protection Relays
KSR-Level sensor KSR-Schwimmer-Magnetschalter 1001-5 KSR Contact Protection s 1 KSR Contact Protection Type KR230-Ex and KR24-Ex General Description The contact protection relays KR230-Ex and KR24-Ex transmit
More informationSwitching power supplies CP range, Linear power supplies CP-L range. Content
CP range, Linear power supplies CP-L range Content Switching power supplies, primary switch mode, CP range Benefits and advantages... 136 Approvals... 137 Ordering details... 138 Technical data... 11 Dimensional
More informationCurrent monitoring relays CM-SRS.M1 For single-phase AC/DC currents
Data sheet Current monitoring relays CM-SRS.M1 For single-phase AC/DC currents The CM-SRS.M1 is an electronic current monitoring relay that monitors single-phase mains (DC or AC) for over- and undercurrent
More informationThree-phase monitoring relays CM-PVS CM-PVS.31, CM-PVS.41 and CM-PVS.81
Data sheet Three-phase monitoring relays CM-PVS CM-PVS.31, CM-PVS.41 and CM-PVS.81 The three-phase monitoring relays CM-PVS.x1 monitor the phase parameters phase sequence, phase failure as well as over-
More informationDATASHEET - ETR4-70-A. Delivery program. Timing relay, 2W, 0.05s-100h, multi-function, VAC/DC, potentiometer connection
DATASHEET - ETR4-70-A Delivery program Timing relay, 2W, 0.05s-100h, multi-function, 24-240VAC/DC, potentiometer connection Part no. ETR4-70-A Catalog No. 031888 Eaton Catalog No. XTTR6A100H70B EL-Nummer
More informationABB NEW. Three-phase monitoring relays. CM-PVS.31 and CM-PVS.41 Data sheet. Features J. Approvals. Marks. Order data. Order data - Accessories
2CDC 251 042 F0t08 CM-PVS.31 Features Monitoring of three-phase mains for phase sequence (can be switched off), phase failure, over- and undervoltage Threshold values for over- and undervoltage are adjustable
More informationMODEL: M2MNV MODEL: M2MNV-[1][2]-[3][4]
Super-mini Signal Conditioners Mini-M Series ANALOG SWITCHING MODULE Functions & Features Switches between two analog signal channels Switches/Distributes one voltage signal to two channels CE marking
More information2.7. IT system floor-standing distribution cabinet Series -IPS-F/EDS
Dipl.-Ing. W. Bender GmbH & Co. KG Londorfer Str. 65 35305 Grünberg Tel.: 0640 807-0 Fax: 0640 807-259 IT system floor-standing distribution cabinet Series -IPS-F/EDS for supplying power to medical locations
More informationPOWER TRANSDUCERS FOR SINGLE-PHASE AND THREE-PHASE NETWORK ISO P11P, P13P and P13B mm SERVICE MANUAL
POWER TRANSDUCERS FOR SINGLE-PHASE AND THREE-PHASE NETWORK PP, PP and PB ISO 900 C E R T Y F I K A T 4 mm SERVICE MANUAL Contents Page. APPLICATION... 2. BASIC REQUIREMENTS.... TRANSDUCER SET... 4 4. TECHNICAL
More informationSEPARATOR P20G TYPE USER S MANUAL
SEPARATOR P20G TYPE USER S MANUAL 1 2 Contents 1. APPLICATION... 5 2. SEPARATOR SET... 5 3. OPERATIONAL SAFETY... 6 4. FITTING... 7 4.1. Fixing Way... 7 4.2. External Connection Diagrams... 8 5. SERVICE...
More informationisolr275 / AGH-LR Digital Ground Fault Monitor / Ground Detector For Low-Resistance Ungrounded (Floating) AC/DC Systems
T M 1 isolr275 / AGH-LR Digital Ground Fault Monitor / Ground Detector For Low-Resistance Ungrounded (Floating) AC/DC Systems Technical Bulletin NAE1012110 / 12.2011 isolr275 / AGH-LR Ground Fault Monitor
More informationFlow - Rotor. Characteristics. Applications. Mechanical-magnetical, Infrared. Quantity measurement for filling processes
GHM Messtechnik GmbH Hans-Sachs-Str. 26 93128 Regenstauf Germany Fon +49 (0) 9402-9383 - 0 Fax +49 (0) 9402-9383 33 www.ghm-messtechnik.de info@ghm-messtechnik.de Flow - Rotor Characteristics Applications
More informationData Sheet KFD2-UFC-EX1.D. Supplied by. .com. Call us on +44 (0)
Data Sheet KFD-UFC-EX1.D Supplied by.com Call us on +44 (0)118 916 940 Email info@47able.com Frequency Converter with Trip Values Features Assembly 1-channel isolated barrier 4 V DC supply (Power Rail)
More informationTechnical Information Nivector FTC968, FTC968Z
TI0007F/00/EN/7.6 7494 Products Solutions Services Technical Information Nivector FTC968, FTC968Z Capacitance Point level switch for powder and fine-grained bulk solids Application The Nivector is a small-sized
More information10/2 Product overview. 10/3 4AC3 0, 4AC3 1 bell transformers. 10/5 4AC AC3 6 transformers for permanent loads. 10/8 4AC2 4 power supply units
BETA Switching Transformers, Bells and Socket Outlets /2 Product overview /3 4AC3 0, 4AC3 1 bell transformers /5 4AC3 4... 4AC3 transformers for permanent loads /8 4AC2 4 power supply units / 7LQ2 2 bells
More information