Waynetown Water Systems Improvements. Division A -New Water Treatment Plant Town of Waynetown, IN. Submittal Review Sheet

Size: px
Start display at page:

Download "Waynetown Water Systems Improvements. Division A -New Water Treatment Plant Town of Waynetown, IN. Submittal Review Sheet"

Transcription

1 Waynetown Water System Improvements Division A -New Water Treatment Plant Town of Waynetown, IN Submittal Review Sheet Attached is the submittal for the Backflow Preventer 3 for the Waynetown Water Systems Improvements project for your review and approval. Thieneman Construction has reviewed the submittal information and added the following notes for your review, approval, and consideration: Items for Commonwealth Engineering: Items for Supplier : 1. Supply materials as requested by TCI. If you have any questions on this submittal information, please call Lewis (317) Thieneman Construction requests your review, approval, and return of one (1) copy of the approved submittals. Project Name: Waynetown Water Systems Improvements Contractor: Thieneman Construction, Inc. Subcontractor / Supplier: Eagle Mechanical Submittal Number: DS Submittal Specification Section: DS-03 Item Description: Backflow Preventer 3 Quantity of Submittals: 1 Electronic Comments: See Above Quantity of Approved Submittals to be Returned: 1 Electronic Signature: Lewis Starr CONTRACTOR S CERTIFICATION Submittal material has been reviewed for compliance with specifications and drawings. Required field measurements have been verified. The work shown on this submittal has been coordinated with other submittals affected by this work. All data has been checked by the Contractor and any variations from the specifications or drawings have been noted. The work described on the submittal material is recommended by the Contractor, and the guarantee in the specifications will apply: Contractor: Thieneman Construction Approved: Lewis Starr Date: 9/15/16

2 BFP-3 BFP-3 BACKFLOW PREVENTER W375STD WILKINS LEAD LAW COMPLIANT 1/2 RPP BACKFLOW PREVENTER Page: 50 / 56

3 BFP-3 BACKFLOW PREVENTER a company FEATURES Sizes: 1/2" 3/4" 1" Maximum working water pressure 175 PSI Maximum working water temperature 180 F Hydrostatic test pressure 350 PSI End connections Threaded FNPT ANSI B OPTIONS - with full port QT ball valves (standard) AG - with air gap ACCESSORIES Air gap (Model AG) Repair kits Thermal expansion tank (Mdl. XT) Shock arrester (Model 1250XL) QT-SET Quick Test Fitting Set Test Cock Lock (Model TCL24) 1/2" & 3/4" (RK34-375BOF) 1" (RK1-375BOF) Model 375ST Stainless Steel Reduced Pressure Principle Assembly SPECIFICATION SUBMITTAL SHEET APPLICATION Designed for installation on potable water lines to protect against both backsiphonage and backpressure of contaminated water into the potable water supply. The Model 375ST provides protection where a potential health hazard exists. The valve's stainless steel construction is ideal in those systems that utilize liquids corrosive to copper alloys. Potential applications include: medical diagnostic equipment, food processing, distilleries, breweries, etc. Additionally, the 375ST is ideal for applications requiring valves that are lead-free*. STANDARDS COMPLIANCE ASSE Listed 1013 CSA B64.4 Approved by the Foundation for Cross Connection Control and Hydraulic Research at the University of Southern California LEAD PLUMBING LAW COMPLIANCE (CA H&S Code , VSA 2470h) *(0.25% MAX. WEIGHTED AVERAGE LEAD CONTENT) MATERIALS Housing Reinforced Nylon, FDA approved Fasteners Stainless Steel, 300 Series Elastomers Silicone (FDA Approved) Buna Nitrile (FDA Approved) Internals Delrin, Nylon, NSF Listed Springs Stainless Steel, 300 series Ball Valves Cast, Stainless Steel ASTM A351, CF-8M Struts Forged Brass, ASTM B 124 Nickel Plated DIMENSIONS & WEIGHTS (do not include pkg.) MODEL 375ST SIZE (Patent No. 7,434,593, 7,784,483 & 7,905,250) Page 1 of 2 DIMENSIONS (approximate) A B C D E F G LESS BALL VALVES WEIGHT WITH BALL VALVES in. mm in. mm in. mm in. mm in. mm in. mm in. mm in. mm lbs. kg lbs. kg 1/ / / / / / / / / / / / / / / / / / / DOCUMENT #: REVISION: BF-375ST 4/12 WILKINS a Zurn company, 1747 Commerce Way, Paso Robles, CA Phone: Fax: In Canada: ZURN INDUSTRIES LIMITED, 3544 Nashua Dr., Mississauga, Ontario L4V 1L2 Phone: Fax: Product Support Help Line: 877-BACKFLOW ( ) Website: Page: 51 / 56

4 ZURN BFP-3 BACKFLOW PREVENTER PRESSURE LOSS (GPM) FLOW CHARACTERISTICS MODEL 375ST 1/2", 3/4" & 1" (STANDARD & METRIC) FLOW RATES (l/s) /4" (20mm) 1/2" (15mm) 1" (25mm) FLOW RATES (GPM) Rated Flow (Established by approval agencies) PRESSURE LOSS (kpa) TYPICAL INSTALLATION Local codes shall govern installation requirements. To be installed in accordance with the manufacturers instructions and the latest edition of the Uniform Plumbing Code. Unless minimum of 12 (305mm) and a maximum of 30 (762mm) testing and maintenance. The installation shall be made so that no part of the unit can be submerged. Capacity thru Schedule 40 Pipe Pipe size 5 ft/sec 7.5 ft/sec 10 ft/sec 15 ft/sec 3/8" /2" /4" " /4" /2" " /4" 375 RP WILKINS 175 PSIG 180ß F (1/2-1 ) 5 1/2 P (1/2-1 ) 2 PIPE (DRAIN LINE CAN BE ANY STANDARD PIPING MATERIAL) FLOOR DRAIN 12 MIN. 30 MAX. DIRECTION OF FLOW INDOOR INSTALLATION OUTDOOR INSTALLATION SPECIFICATIONS rd states' lead plumbing law 0.25% maximum weighted average lead content requirement, ASSE Listed 1013, rated to 180 F and supplied with full port ball valves. The main body shall be Nylon and the seat disc elastomers shall be silicone. If installed indoors, the installation shall be supplied with an air gap adapter. The Reduced Pressure Principle WILKINS a Zurn company, 1747 Commerce Way, Paso Robles, CA Phone: Fax: IN CANADA: ZURN INDUSTRIES LIMITED, 3544 Nashua Dr., Mississauga, Ontario L4V 1L2 Phone: Fax: Product Support Help Line: 877-BACKFLOW ( ) Website: Page 2 of 2 Page: 52 / 56

5 Page: 56 / 56

Waynetown Water Systems Improvements. Division A -New Water Treatment Plant Town of Waynetown, IN. Submittal Review Sheet

Waynetown Water Systems Improvements. Division A -New Water Treatment Plant Town of Waynetown, IN. Submittal Review Sheet Waynetown Water System Improvements Division A -New Water Treatment Plant Town of Waynetown, IN Submittal Review Sheet Attached is the submittal for the Lavatory for the Waynetown Water Systems Improvements

More information

Submittal Transmittal

Submittal Transmittal Commonwealth Engineers, Inc. 7256 Company Drive Indianapolis IN 46237 United States Submittal Transmittal PROJECT: Waynetown - Water-Strmwtr Imprv-Div A J13046-A DATE SENT: 9/28/2016 SUBJECT: DS-22-15_Lavatory

More information

Waynetown Water Systems Improvements. Division A -New Water Treatment Plant Town of Waynetown, IN. Submittal Review Sheet

Waynetown Water Systems Improvements. Division A -New Water Treatment Plant Town of Waynetown, IN. Submittal Review Sheet Waynetown Water System Improvements Division A -New Water Treatment Plant Town of Waynetown, IN Submittal Review Sheet Attached is the submittal for the Utility Sink for the Waynetown Water Systems Improvements

More information

General Information. Ball Curb Valve

General Information. Ball Curb Valve General Information 1. All Jones Curb Valves are manufactured in accordance with the AWWA Standard C-800-latest revision. 1. Copper Alloy CDA No. C83600 (85-5-5-5) 2. Copper Alloy CDA No. 89520 (Low Lead)

More information

A. This Section includes plumbing fixtures and related components.

A. This Section includes plumbing fixtures and related components. SECTION 224200 PLUMBING FIXTURES PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification

More information

This specification describes the minimum requirements for piping systems for the following service:

This specification describes the minimum requirements for piping systems for the following service: 201/11/2 1/9 1.0 APPLICATION This specification describes the minimum requirements for piping systems for the following service: Underground Service Water Note: This specification does not apply to piping

More information

SECTION PLUMBING FIXTURES

SECTION PLUMBING FIXTURES SECTION 224000 - PLUMBING FIXTURES PART 1 - GENERAL 1.1 SUMMARY A. This Section includes 1. Faucets for lavatories and sinks. 2. Flushometers. 3. Toilet seats. 4. Protective shielding guards. 5. Fixture

More information

This specification describes the minimum requirements for service water piping systems (ie: cooling water, process water, etc.), located on surface.

This specification describes the minimum requirements for service water piping systems (ie: cooling water, process water, etc.), located on surface. SPEC-3500 1/9 1.0 PURPOSE This specification describes the minimum requirements for service water piping systems (ie: cooling water, process water, etc.), located on surface. Note: This specification does

More information

Submittal Transmittal

Submittal Transmittal Commonwealth Engineers, Inc. 7256 Company Drive Indianapolis IN 46237 United States Submittal Transmittal PROJECT: SUBJECT: Waynetown - Water-Strmwtr Imprv-Div A J13046-A DS-23-01 A_Engine Generators &

More information

Stainless Steel Flexible Water Connectors. Dependable. Durable. Professional.

Stainless Steel Flexible Water Connectors. Dependable. Durable. Professional. Stainless Steel Flexible Water Connectors Dependable. Durable. Professional. BrassCraft Stainless Steel Flexible Water Connector The Professional Standard Designed with superior craftsmanship, the BrassCraft

More information

This specification describes the minimum requirements for piping systems for the following service:

This specification describes the minimum requirements for piping systems for the following service: SPEC-3501 1/ 1.0 APPLICATION This specification describes the minimum requirements for piping systems for the following service: Instrument Air Design Conditions 150 PSIG @ 180 F Operating Conditions 125

More information

Your Global Sales Partner

Your Global Sales Partner Your Global Sales Partner www.techlineint.com THE TECHLINE COMMITMENT As a leader in global sourcing since 1982, we are dedicated to placing the world s manufacturing capabilities within the grasp of our

More information

A representative from Occupational Health is to be involved in the commissioning process to address any Respiratory Protection Program requirements.

A representative from Occupational Health is to be involved in the commissioning process to address any Respiratory Protection Program requirements. SPEC-3017 1/8 1.0 PURPOSE This specification describes the minimum requirements for the installation of breathing air distribution systems (indoor and outdoor) up to the connection to the breathing air

More information

This specification describes the minimum requirements for piping systems for the following service:

This specification describes the minimum requirements for piping systems for the following service: 201/01/13 1/ 1.0 APPLICATION This specification describes the minimum requirements for piping systems for the following service: Service Air Design Conditions Operating Conditions Blast Air (see Note 1)

More information

QUALITY ASSURANCE SPECIFICATION

QUALITY ASSURANCE SPECIFICATION Page 1 of 8 QAS: 2.02 QUALITY ASSURANCE SPECIFICATION REVISION: 0 DATE: 08/29/14 MATERIAL PURCHASING Code Material Purchase Specification for Pipe, Valves, Fitting, and Flanges PAGE 1 OF 8 1.0 Purpose

More information

We Are the Worldwide Provider for All Your Valve and Fitting Needs

We Are the Worldwide Provider for All Your Valve and Fitting Needs Product Catalog We Are the Worldwide Provider for All Your and Fitting Needs C&C strives to earn your business by offering an extensive line of high quality products with a proven track record for successful

More information

This specification describes the minimum requirements for piping systems for the following service:

This specification describes the minimum requirements for piping systems for the following service: SPEC-3004 1/7 1.0 APPLICATION This specification describes the minimum requirements for piping systems for the following service: Service Water Design Conditions Operating Conditions 10 PSIG @ 33 o F to

More information

Quick-Drain Installation Requirements

Quick-Drain Installation Requirements Quick-Drain Installation Requirements Installation of the Quick-Drain-QF and Quick-Drain-HF Fluid Management Systems is a straightforward process. These installation instructions are written in a general

More information

Product Guide Specification

Product Guide Specification Shield Casework February 2014 3421 Merriam Lane Overland Park, Kansas 66203 Phone 913-744-2183 Fax 913-384-3477 Website www.shieldcasework.com E-mail info@shieldcasework.com Product Guide Specification

More information

SECTION SWINGING AUTOMATIC ENTRANCES IN-GROUND, AUTOMATIC SWING DOOR OPERATOR CONVERTER ADAPTED TO BROOKFIELD NB-500 EXTREME DUTY OPERATOR

SECTION SWINGING AUTOMATIC ENTRANCES IN-GROUND, AUTOMATIC SWING DOOR OPERATOR CONVERTER ADAPTED TO BROOKFIELD NB-500 EXTREME DUTY OPERATOR SECTION 084229.33 SWINGING AUTOMATIC ENTRANCES IN-GROUND, AUTOMATIC SWING DOOR OPERATOR CONVERTER ADAPTED TO BROOKFIELD NB-500 EXTREME DUTY OPERATOR PART 1-GENERAL 1.01 DESCRIPTION A. This section describes

More information

Quick-Drain Installation Requirements Large Volume Drainage Models

Quick-Drain Installation Requirements Large Volume Drainage Models Quick-Drain Installation Requirements Large Volume Drainage Models Installation of the Quick-Drain-QFLV and Quick-Drain-HFLV Fluid Management Systems is a straightforward process. These installation instructions

More information

FUEL GAS PIPING SECTION A. The provisions of SECTION 15010, MECHANICAL GENERAL REQUIREMENTS, apply to this section.

FUEL GAS PIPING SECTION A. The provisions of SECTION 15010, MECHANICAL GENERAL REQUIREMENTS, apply to this section. FUEL GAS PIPING SECTION 15355 PART 1 GENERAL 1.1 DESCRIPTION A. The provisions of SECTION 15010, MECHANICAL GENERAL REQUIREMENTS, apply to this section. B. This specification covers both interior and exterior

More information

SECTION FUEL OIL SYSTEM (PLUMBING)

SECTION FUEL OIL SYSTEM (PLUMBING) SECTION 15484 FUEL OIL SYSTEM (PLUMBING) PART 1 GENERAL 1.01 SUMMARY A. Related Sections: 1. 02221 - Excavating, Backfilling, and Compaction for Utilities. 2. 03300 - Cast-In-Place Concrete. 3. 15410 -

More information

.1 Materials and installation for steel piping, valves and fittings for hydronic systems in building services piping..2 Related Sections.

.1 Materials and installation for steel piping, valves and fittings for hydronic systems in building services piping..2 Related Sections. Issued 2006/08/01 Section 15183 Hydronic Systems: Steel Page 1 of 6 PART 1 GENERAL 1.1 SUMMARY.1 Section Includes..1 Materials and installation for steel piping, valves and fittings for hydronic systems

More information

SAUSALITO-MARIN CITY SANITARY DISTRICT MISCELLANEOUS UPGRADES PROJECT. Addendum No. 2

SAUSALITO-MARIN CITY SANITARY DISTRICT MISCELLANEOUS UPGRADES PROJECT. Addendum No. 2 SAUSALITO-MARIN CITY SANITARY DISTRICT MISCELLANEOUS UPGRADES PROJECT Addendum No. 2 The following shall modify the Contract Documents. The work shall be accomplished in accordance with such modifications.

More information

FNW can handle all your hanger and fastener needs, all in one place. FNW products are sold exclusively at Ferguson.

FNW can handle all your hanger and fastener needs, all in one place. FNW products are sold exclusively at Ferguson. FASTENERS PIPE HANGERS, SUPPORTS & STRUT ACCESSORIES FNW can handle all your hanger and fastener needs, all in one place. FNW products are sold exclusively at Ferguson. Quick Reference Nuts Heavy Hex Nuts...4

More information

FAIRBANKS NIJHUIS 1590 SERIES SINGLE STAGE VERTICAL INLINE PUMP.

FAIRBANKS NIJHUIS 1590 SERIES SINGLE STAGE VERTICAL INLINE PUMP. FAIRBANKS NIJHUIS 0 SERIES SINGLE STAGE VERTICAL INLINE PUMP www.fairbanksnijhuis.com FAIRBANKS NIJHUIS 0 Series Single Stage Vertical Inline Pump Capacities to 00 GPM (,00 m/hr) Heads to 0 Feet ( m) Temperatures

More information

Essex County College - West Essex Campus Addition And Renovations dlb # / SECTION EXPANSION FITTINGS AND LOOPS FOR HVAC PIPING

Essex County College - West Essex Campus Addition And Renovations dlb # / SECTION EXPANSION FITTINGS AND LOOPS FOR HVAC PIPING SECTION 230516 - EXPANSION FITTINGS AND LOOPS FOR HVAC PIPING PART I - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and

More information

American Society of Sanitary Engineering PRODUCT (SEAL) LISTING PROGRAM

American Society of Sanitary Engineering PRODUCT (SEAL) LISTING PROGRAM American Society of Sanitary Engineering PRODUCT (SEAL) LISTING PROGRAM ASSE STANDARD #1051 - REVISED: 2009 Individual and Branch Type Air Admittance Valves MANUFACTURER: CONTACT PERSON: E-MAIL: ADDRESS:

More information

PLASTIC BALLCOCK Includes: Vinyl Refill Tube, Float Rod, Flange Nut, Washer, 5/8 or 1/2 Coupling Nut and Water Level Adjustable Screw.

PLASTIC BALLCOCK Includes: Vinyl Refill Tube, Float Rod, Flange Nut, Washer, 5/8 or 1/2 Coupling Nut and Water Level Adjustable Screw. Flush Valves PLASTIC BALLCOCK Includes: Vinyl Refill Tube, Float Rod, Flange Nut, Washer, 5/8 or 1/2 Coupling Nut and Water Level Adjustable Screw. Toilet Flappers 51005 10 Anti siphon 5 50 6.25 P51005

More information

3-Way Ball Valves. Overview. Applications. Features & Benefits. Datasheet

3-Way Ball Valves. Overview. Applications. Features & Benefits. Datasheet 3-Way Ball s Datasheet Overview 3-way Ball s are coupled with DA-Series Actuators to provide three-way mixing or diverting flow control. The ball valves are 1/4-turn rotary control valves and are available

More information

2. All work and materials shall be in full accordance with Local and State ordinance and with any prevailing rules and regulations.

2. All work and materials shall be in full accordance with Local and State ordinance and with any prevailing rules and regulations. General Conditions: 1. Deliver all food service equipment as specified herein, including that which is reasonably inferred, with all related items necessary to complete work shown on contract drawings

More information

Series 80 In-Line Mounted Centrifugal Pumps

Series 80 In-Line Mounted Centrifugal Pumps Bulletin B-G Bell & Gossett Series In-Line Mounted Centrifugal Pumps Applications Hydronic Heating & Cooling Systems Industrial Process General Service Pressure Boosting Advantages Close Coupled Space

More information

FIELD DEVICES PRESSURE

FIELD DEVICES PRESSURE FIELD DEVICES PRESSURE Product Specifications Models 11GM and 11GH Pneumatic Transmitters for Gauge Pressure Measurement 11GM TRANSMITTER 11GH TRANSMITTER The Foxboro brand Models 11GM and 11GH Transmitters

More information

Fitting C.O. Adapter

Fitting C.O. Adapter ABS-DWV Fittings ABS/DWV Service Weight Pipe Schedule 30 Single step solvent cementing procedures no primer required. Excellent solvent cementing characteristics. Black. 84/Ctn. x h Hub Sanitary 0321612

More information

SECTION SWINGING AUTOMATIC ENTRANCES

SECTION SWINGING AUTOMATIC ENTRANCES SECTION 084229.33 SWINGING AUTOMATIC ENTRANCES IN-GROUND, AUTOMATIC SWING DOOR OPERATOR CONVERTER ADAPTED TO IR/DOR-O-MATIC SENIOR SWING & ASTRO SWING OPERATOR PART 1-GENERAL 1.01 DESCRIPTION A. This section

More information

SS Band for increased durability (except 1/2 inch) 4000 PSI

SS Band for increased durability (except 1/2 inch) 4000 PSI COUPLERS Legacy Quick Couplers Legacy Brass Couplers give Premium Performance with Economy Price. Legacy Quick Connect Couplings are machined from top grade materials to the same exacting specifications

More information

DF-Series Pneumatic Couplings

DF-Series Pneumatic Couplings Interchange Data: Parker 20-Series Manual Interchange (F-Series) Parker 30-Series Automatic Interchange (D-Series) Foster 3, 4, 5, and 6 Series Hansen 1000, 400, 500 (F-Series) Hansen 3000, 4000, 5000,

More information

5.1 MUELLER CORPORATION VALVES. MUELLER 300 Ball Type Corporation Valves

5.1 MUELLER CORPORATION VALVES. MUELLER 300 Ball Type Corporation Valves MUELLER CORPORATION VALVES 5.1 Shaded area indicates changes Rev. 4-14 Machine inserted corporation stops were developed by Hieronymus Mueller in conjunction with his development of the drilling and tapping

More information

Piping & Equipment Identification

Piping & Equipment Identification Piping & Equipment Identification Part 1 General 1.01 Description of Work A. Work in this section includes: Identification materials, including necessary accessories indicated on Contract Documents and

More information

STANDARD PHRASEOLOGY SECTION G. 1. This section of standard phraseology is for general use in piping disciplines.

STANDARD PHRASEOLOGY SECTION G. 1. This section of standard phraseology is for general use in piping disciplines. STANDARD PHRASEOLOGY SECTION G 1. This section of standard phraseology is for general use in piping disciplines. Hydrostatically test, using at PSIG for a minimum of minutes. Allowable leakage: None. G1

More information

Single-Phase Mini Pad-Mounted Transformer Specification: Energy+ MPDL

Single-Phase Mini Pad-Mounted Transformer Specification: Energy+ MPDL Single-Phase Mini Pad-Mounted Transformer Specification: Energy+ MPDL Issued by: Approved by: Engineering Department Energy+ Inc. September 2016 Shawn Jackson, P.Eng. Approval is given in accordance with

More information

SECTION EXPANSION FITTINGS AND LOOPS FOR HVAC PIPING

SECTION EXPANSION FITTINGS AND LOOPS FOR HVAC PIPING SECTION 230516 - EXPANSION FITTINGS AND LOOPS FOR HVAC PIPING PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and

More information

Installation Tools. Pipe Cutters for steel and cast iron pipes 598. Deburring Reamer / for stainless steel pipes 600. for copper pipes 602

Installation Tools. Pipe Cutters for steel and cast iron pipes 598. Deburring Reamer / for stainless steel pipes 600. for copper pipes 602 596 597 Installation Tools Pipe Cutters for steel and cast iron pipes 598 Pipe Cutters / Pipe Deburring Reamer for stainless steel pipes 600 Pipe Cutters / Pipe Deburring Reamer / Calibrating Tool for

More information

Page 1 of 12 Second Revision No. 5-NFPA 12-2014 [ Section No. 2.3.4 ] 2.3.4 ASTM Publications. ASTM International, 100 Barr Harbor Drive, P.O. Box C 700, West Conshohocken, PA 19428-2959. ASTM A53, Standard

More information

ADDENDUM NO. 1 TO THE CONTRACT DOCUMENTS AND SPECIFICATIONS DATED JULY 2017 FLORIDA GOVERNMENTAL UTILITY AUTHORITY PROJECT NO.

ADDENDUM NO. 1 TO THE CONTRACT DOCUMENTS AND SPECIFICATIONS DATED JULY 2017 FLORIDA GOVERNMENTAL UTILITY AUTHORITY PROJECT NO. ADDENDUM NO. 1 TO THE CONTRACT DOCUMENTS AND SPECIFICATIONS DATED JULY 2017 FLORIDA GOVERNMENTAL UTILITY AUTHORITY PROJECT NO. PS 061 SEVEN SPRINGS WASTEWATER TREATMENT FACILITY IMPROVEMENTS PASCO COUNTY,

More information

11A Series Absolute Pressure Transmitters

11A Series Absolute Pressure Transmitters Product Specifications 11A Series Absolute Pressure Transmitters PSS 2B-1A1 A 11 SERIES TRANSMITTER 11 SERIES TRANSMITTER 11 SERIES TRANSMITTER In 11A Series Transmitters, the reliable force-balance d/p

More information

SUBMITTAL LIST Note: See tab below for Samples and Instructions. Attach to end of Specification Section when complete.

SUBMITTAL LIST Note: See tab below for Samples and Instructions. Attach to end of Specification Section when complete. REQUIREMENTS (indicate with an "") 011100 1.4 Detailed Construction Phasing Plan 011100 1.4 Sub-Surface Utility Location Plan 013100 1.3 Letter Designating Project Superintendent 013100 1.3 Construction

More information

IP26 Series Current to Pneumatic Converter

IP26 Series Current to Pneumatic Converter Product Specifications 06.2016 PSS EVE0403 A-(en) IP26 Series Current to Pneumatic Converter The IP26 (current to pressure) transducer converts a 4 20mA electrical current signal to a proportional linear

More information

Threadlocking Adhesives

Threadlocking Adhesives Threadlocking Adhesives Locking of Threaded Fasteners Why use a Threadlocker? threadlocking products prevent self-loosening and secure any threaded fastener against vibration and shock loads. They are

More information

CONSTRUCTION PRODUCT TECHNICAL CARD

CONSTRUCTION PRODUCT TECHNICAL CARD CONSTRUCTION PRODUCT TECHNICAL CARD Product feature: Manufacturer: Flowmeter included ASPOL-FV Łódź, ul. Helska 39/45 www.aspol.com.pl Energeo product: SPIDER R Distributor well with multi-sectional manifolds

More information

SECTION CABLE TRAYS FOR COMMUNICATIONS SYSTEMS

SECTION CABLE TRAYS FOR COMMUNICATIONS SYSTEMS SECTION 270536 - CABLE TRAYS FOR COMMUNICATIONS SYSTEMS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division

More information

TRANSMITTAL LETTER. As Builts Change Order Contract Copy of Letter Insurance. For approval Approved as submitted Resubmit copies for approval

TRANSMITTAL LETTER. As Builts Change Order Contract Copy of Letter Insurance. For approval Approved as submitted Resubmit copies for approval Redwood City Electric, Inc. TRANSMITTAL LETTER To: Transworld Construction, Inc. 1178 Folsom Street San Francisco, CA 94103 Date: 05/31/12 Job #: 9340 Regarding: SFO DATA CENTER Attn: Rob Acero We are

More information

STANDARD PHRASEOLOGY SECTION G. 1. This section of standard phraseology is for general use in piping disciplines.

STANDARD PHRASEOLOGY SECTION G. 1. This section of standard phraseology is for general use in piping disciplines. STANDARD PHRASEOLOGY SECTION G 1. This section of standard phraseology is for general use in piping disciplines. Hydrostatically test, using at PSIG for a minimum of minutes. Allowable leakage: None. G1

More information

Engineering Data Single Reduction Parts List Item # Description Basic Single Reduction Unit 1. Gear Housing 2. Pipe Plug 3. Vent Plug 4. Splash Guard

Engineering Data Single Reduction Parts List Item # Description Basic Single Reduction Unit 1. Gear Housing 2. Pipe Plug 3. Vent Plug 4. Splash Guard Engineering Data Single Reduction Parts List Item # Description Basic Single Reduction Unit 1. Gear Housing 2. Pipe Plug 3. Vent Plug 4. Splash Guard 5. Input Cover 6. O-Ring 7. Hex Head Cap Screw 8. Input

More information

SECTION BASIC MATERIALS AND METHODS

SECTION BASIC MATERIALS AND METHODS SECTION 15050 BASIC MATERIALS AND METHODS PART 1 - GENERAL 1.01 SECTION INCLUDES A. Pipe and Fittings. 1.02 RELATED SECTIONS A. Basic Mechanical Requirements: Section 15010. B. Supports, Anchors, and Seals:

More information

Product range Cable Glands

Product range Cable Glands Product range Cable Glands Hazardous areas material: brass, nickel plated brass, INOX 316L sizes: M 16 M 75, NPT 3/8" NPT 3" types: Standard, Barrier, MZ, A2F Ex d Ex e group: I, II, III type of protection:

More information

COUPLERS, FITTINGS & FILTERS

COUPLERS, FITTINGS & FILTERS Quick Couplers Precision brass design Unrestricted free flow 4000 PSI Brass Couplers, designed for 4000 PSI and extended durability. Affordable and rugged all in one. 826169 1/4" FNPT 826176 3/8" FNPT

More information

M1 series 2 way ball valve with integrated Praher Labeling System

M1 series 2 way ball valve with integrated Praher Labeling System General: Material: PVC-U Seal material: EPDM / FPM Ball seating joint: PTFE Dimensions: DN10 DN50 d16 d63 d3/8 d2 Connection types: Solvent socket DIN / ASTM / JIS Solvent spigot DIN Threaded socket BSP

More information

Multi-Set II Drop-In Anchors

Multi-Set II Drop-In Anchors CONCRETE ANCHORING SPECIALISTS Internally Threaded Heavy- Duty Anchoring Systems DESCRIPTION/SUGGESTED SPECIFICATIONS Drop-In, Shell-Type Anchors SPECIFIED FOR ANCHORAGE INTO CONCRETE Drop-In, shell-type

More information

Repair Manual 12 PL PILOT

Repair Manual 12 PL PILOT Repair Manual 12 PL PILOT 12 PL PILOT REPAIR MANUAL INDEX Introduction... 1 Elastomer Materials... 2 Disassembly... 3 Assembly... 7 Testing... 11 NOTE: We reserve the right to modify or change, without

More information

Overhead Concealed Closers

Overhead Concealed Closers Overhead Concealed Closers Introduction Rixson Overhead Concealed closers offer an aesthetically appealing way to close a door. In situations where a closer is needed but concealment is required, Rixson

More information

Flash Rough-In Valves

Flash Rough-In Valves Flash Rough-In Valves American Standard I Flash Rough-In Valves I 1 Take Your Time Back At American Standard, we are constantly thinking about how our products can improve the way you work every day. Every

More information

Part No. Original Part No. Original MPT No. FPT No. Description. Part No. Original Part No. Original MPT No. FPT No. Description

Part No. Original Part No. Original MPT No. FPT No. Description. Part No. Original Part No. Original MPT No. FPT No. Description COUPLERS Legacy Quick Couplers Legacy Brass Couplers give Premium Performance with Economy Price. Legacy Quick Connect Couplings are machined from top grade materials to the same exacting specifications

More information

Submittal Packages Detailed with Items and Reviewers

Submittal Packages Detailed with Items and Reviewers Submittal Packages Detailed with Items and Reviewers Tenochca Upgrades Project # 1 San Diego State University 00 Campanile Drive San Diego, CA 918 Tel: 619-94-740 Fax: 0079-1116-0 Circulating Pump Author

More information

Introduction. Classifications of piping: Industrial. Residential (i.e., plumbing) Carries liquids and gases used in the manufacture of products

Introduction. Classifications of piping: Industrial. Residential (i.e., plumbing) Carries liquids and gases used in the manufacture of products Plumbing Plans Introduction Classifications of piping: Industrial Carries liquids and gases used in the manufacture of products Residential (i.e., plumbing) Carries fresh water, gas, liquid, solid waste

More information

CENTRIFUGAL PUMPS FRAME MOUNT 13" FEATURES

CENTRIFUGAL PUMPS FRAME MOUNT 13 FEATURES FEATURES Volute: Cast iron for heavy-duty service; back pullout design; can be rotated for ease of installation; 6 x 8-13 and 8 x 10-13 are split volutes for reduction in radial bearing load Impeller:

More information

NAVSEA STANDARD ITEM T9074-AS-GIB-010/271, Requirements for Nondestructive Testing Methods

NAVSEA STANDARD ITEM T9074-AS-GIB-010/271, Requirements for Nondestructive Testing Methods NAVSEA STANDARD ITEM ITEM NO: 009-48 DATE: 29 JUL 2011 CATEGORY: II 1. SCOPE: 1.1 Title: Pressure Seal Bonnet Valve; repair (shop) 2. REFERENCES: 2.1 S9086-CJ-STM-010/CH-075, Fasteners 2.2. T9074-AS-GIB-010/271,

More information

T&S BRASS AND BRONZE WORKS, INC.

T&S BRASS AND BRONZE WORKS, INC. B-74-01 Travelers Rest, SC: 800-476-4103 Simi Valley, CA: 800-43-0150 Fax: 864-834-3518 www.tsbrass.com This Space for Architect/Engineer Approval Job Name Date Model Specified Quantity Customer/Wholesaler

More information

SECTION THERAPEUTIC POOL ACCESSORIES

SECTION THERAPEUTIC POOL ACCESSORIES PART 1 - GENERAL 1.1 DESCRIPTION: SECTION 13 17 23.11 THERAPEUTIC POOL ACCESSORIES SPEC WRITER NOTES: Delete between // // if not applicable to project. Also, delete any other item or paragraph not applicable

More information

PRESSURE WASHERS Davis Road, Suite J Elgin, IL (800) Professional 2018 Price List

PRESSURE WASHERS Davis Road, Suite J Elgin, IL (800) Professional 2018 Price List PRESSURE WASHERS 1150 Davis Road, Suite J Elgin, IL 60123 (800) 788-8867 info@lorchem.com www.lorchem.com Professional 2018 Price List 2018 For more information, contact Lorchem Technologies at: (800)

More information

Product Guide Specification

Product Guide Specification HALFEN USA Inc. March 2012 8521 FM 1976 P.O. Box 547 Converse, TX 78109 Toll Free 800-423-9140 Fax 888-277-1695 Website www.halfenusa.com E-mail info@halfenusa.com Product Guide Specification Specifier

More information

Submittal Data Sheet Wilo MVI - Vertical Multistage Pumps

Submittal Data Sheet Wilo MVI - Vertical Multistage Pumps Wilo MVI Project: Engineer: Contractor: Submitted By: Date: Approved By: Date: Tag # Model # Flow Head HP Cycle Phase Voltage RPM Hz H [ft] ηp [%] P [hp] 7 7.......7..9.......................... MVI -

More information

Effective Date: October Rev. 5/11/2018- Void After: October 2018

Effective Date: October Rev. 5/11/2018- Void After: October 2018 IAPMO Research and Testing, Inc. is a product certification body which tests and inspects samples taken from the supplier's stock or from the market or a combination of both to verify compliance to the

More information

Rodney Hunt. A GA Industries Company Glydaseal Gates

Rodney Hunt. A GA Industries Company Glydaseal Gates Rodney Hunt A GA Industries Company Glydaseal Gates GUIDE BRONZE GUIDE BAR FRAME NUT POCKET SEAT FACING RESILIENT INVERT SEAT DISC GUIDE BAR ADJUSTMENT BOLT WITH LOCK NUT GUIDE BAR ATTACHING BOLT The Glydaseal

More information

Thermoplastic Valves Sewer Disconnect

Thermoplastic Valves Sewer Disconnect Sewer onnect Spears Sewer onnect functions as both cleanout and disconnect device, plus helps prevent sewage backup during hurricanes and floods. Complete unit consists of body and plunger (sold separately

More information

We are one of the leading manufacturers and Suppliers of a wide range of Precision Engineering Products. Due to their dimensional accuracy, easy installation and low maintenance, these products are highly

More information

A. Compatibility: Products shall be suitable for piping service fluids, materials, working pressures, and temperatures.

A. Compatibility: Products shall be suitable for piping service fluids, materials, working pressures, and temperatures. SECTION 22 05 16 LOOPS FOR PLUMBING PIPING PART 1 - GENERAL 1.01 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification

More information

B34 Series Regulator Commercial and Industrial Regulator

B34 Series Regulator Commercial and Industrial Regulator B34 Series Regulator Commercial and Industrial Regulator Appropriate for many commercial and industrial uses such as gas engines, burners, furnaces and boilers. The rapid response of the B34 is particularly

More information

PRODUCT CATALOGUE. Major Features: Arc Bends Manufactured to: Pipestar now offering full-line of flanged Arcbends

PRODUCT CATALOGUE. Major Features: Arc Bends Manufactured to: Pipestar now offering full-line of flanged Arcbends PRODUCT CATALOGUE Pipestar now offering full-line of flanged Arcbends Pipestar offers a range of seamless long radius Arc HDPE sweep bends made to the highest quality standards. Pipestar offers a range

More information

SECTION 10520: FIRE EXTINGUISHERS AND CABINETS

SECTION 10520: FIRE EXTINGUISHERS AND CABINETS SECTION 10520: FIRE EXTINGUISHERS AND CABINETS PART 1 GENERAL 1.01 GENERAL REQUIREMENTS: A. This section specifies fire extinguishers, cabinets for fire extinguishers, fire and other accessories. Their

More information

Note: Do not bury sulphur dioxide lines Use stainless steel pipe and fittings only where specified on project drawings.

Note: Do not bury sulphur dioxide lines Use stainless steel pipe and fittings only where specified on project drawings. 1/7 1.0 APPLICATION This specification describes the minimum requirements for piping systems for the following service: Liquid and High Pressure Gaseous Dry Sulphur Dioxide (Less than 100 ppm of water)

More information

RCM DIRECT READING FLOWMETER

RCM DIRECT READING FLOWMETER RCM DIRECT READING FLOWMETER Flow Pressure Level Temperature measurement monitoring control Special Features Compact Design Easy to Install For Horizontal or Vertical Pipes Rugged Construction Accuracy:

More information

9. Construction Activities

9. Construction Activities 9. Construction Activities DIABLO WATER DISTRICT STANDARD SPECIFICATIONS AND DRAWINGS CONSTRUCTION ACTIVITIES I. Construction Sequence and Requirements II. Construction Submittal Checklist DIABLO WATER

More information

MUNICIPAL INDUSTRIAL CONSTRUCTION / RENTAL AGRICULTURE. SF Series Submersible Solids-Handling Pumps

MUNICIPAL INDUSTRIAL CONSTRUCTION / RENTAL AGRICULTURE. SF Series Submersible Solids-Handling Pumps MUNICIPAL INDUSTRIAL CONSTRUCTION / RENTAL AGRICULTURE SF Series Submersible Solids-Handling Pumps A History of Innovation 2 Gorman-Rupp has been revolutionizing the pumping industry since 1933. Over the

More information

CITY OF TOMBALL. Section FIRE HYDRANTS 1.01 SECTION INCLUDES. A. Fire hydrants. B. Adjustment of fire hydrants and gate valves.

CITY OF TOMBALL. Section FIRE HYDRANTS 1.01 SECTION INCLUDES. A. Fire hydrants. B. Adjustment of fire hydrants and gate valves. Section 02520 PART 1 G E N E R A L 1.01 SECTION INCLUDES A. Fire hydrants. B. Adjustment of fire hydrants and gate valves. 1.02 MEASUREMENT AND PAYMENT A. Unit Prices. 1. Payment is on a unit price basis

More information

ADDENDUM NO. 3 PROJECT: COURTLAND PUMP STATION CONTRACT: IFB NO COM.00030

ADDENDUM NO. 3 PROJECT: COURTLAND PUMP STATION CONTRACT: IFB NO COM.00030 ADDENDUM NO. 3 PROJECT: COURTLAND PUMP STATION CONTRACT: IFB NO. 2018-008-COM.00030 To: Prospective Bidders of Record Date: January 8, 2019 The following changes, additions, revisions, and/or deletions

More information

Section Meetings Section Material and Equipment. None Required

Section Meetings Section Material and Equipment. None Required January 2000 Page 1 of 8 PART 1 GENERAL 1.01 OTHER CONTRACT DOCUMENTS 1.02 DESCRIPTION OF WORK 1.03 RELATED WORK PART 2 PRODUCTS The General Conditions of the Contract, General Requirements and Supplemental

More information

Trade of Metal Fabrication. Module 5: Pipe Fabrication Unit 3: Flanges Phase 2

Trade of Metal Fabrication. Module 5: Pipe Fabrication Unit 3: Flanges Phase 2 Trade of Metal Fabrication Module 5: Pipe Fabrication Unit 3: Flanges Phase 2 Table of Contents List of Figures... 4 List of Tables... 5 Document Release History... 6 Module 5 Pipe Fabrication... 7 Unit

More information

Heat Exchanger Construction Checklist

Heat Exchanger Construction Checklist Heat Exchanger Checklist Project: Pump tag: Building: Location: Submittal / Approvals Submittal. The above equipment and systems integral to them are complete and ready for functional testing. The checklist

More information

Precision Chucks for Improved Accuracy and Increased Productivity

Precision Chucks for Improved Accuracy and Increased Productivity Precision Workholding Technology Precision Chucks for Improved Accuracy and Increased Productivity Precision Air Chucks (Self Contained Design) MicroCentric Precision Air Chucks feature a patented open

More information

Submittal Transmittal

Submittal Transmittal Submittal Transmittal Standard St. Joe's - Sonntag Pavillion St. Joseph s Hospital 350 W. Thomas Road Phoenix, AZ 85013 Project # 5690A Tel: Fax: Kitchell Contractors Inc of AZ Date: 10/7/2011 Reference

More information

Installation Instructions TMW Antenna Tower Mount for 4ft (1.2m) Antennas.

Installation Instructions TMW Antenna Tower Mount for 4ft (1.2m) Antennas. Description The following pages show the steps required to assembly and fit the antenna mount to a vertical tower pipe of diameter 48 to 115 mm (1.9 to 4.5"). This mount provides ±20 azimuth or ±15 elevation

More information

Stainless Steel CNC Machined Parts Turned Components :

Stainless Steel CNC Machined Parts Turned Components : STAINLESS STEEL CNC MACHINED PARTS TURNED COMPONENTS Stainless Steel CNC Machined Parts Turned Components : We create metal turned parts with virtually any material including aluminum, brass, cast iron,

More information

ER WIRELESS TRANSMITTER

ER WIRELESS TRANSMITTER ER WIRELESS TRANSMITTER ER-310 / ER-320 Cosasco s Electrical Resistance (ER) Wireless Transmitters are based on Cosasco s ER corrosion measurement technology, the industry s most widely used and only technology

More information

LETTER OF TRANSMITTAL

LETTER OF TRANSMITTAL LETTER OF TRANSMITTAL Max Foote Construction Company, LLC 225 Antibes West Mandeville, LA 70448 Telephone: (985)-624-8569 Fax: (985)-624-8580 Date: 08/29/2016 Job #: 289-11150 Submittal #: D-11235-001-A

More information

Ford Water Meter Couplings & Accessories

Ford Water Meter Couplings & Accessories Section H 2/2001 Ford Water Meter Couplings & Accessories The Ford Meter Box Co., Inc. 775 Manchester Avenue, P.O. Box 443, Wabash, Indiana, USA 46992-0443 Telephone: 260/563-3171 FAX: 1-800-826-3487 Overseas

More information

TECHNICAL SPECIFICATION FOR LEVEL CONTROL VALVE HANDLING WATER

TECHNICAL SPECIFICATION FOR LEVEL CONTROL VALVE HANDLING WATER ANNEXURE-C TO TENDER BAP/FGD/2012/OT-1 BONGAIGAON 3X250 MW FLUE GAS DESULFURIZATION SYSTEM TECHNICAL SPECIFICATION LEVEL CONTROL VALVE HANDLING WATER CUSTOMER : NATIONAL THERMAL POWER CORPORATION LIMITED

More information

High Precision Air Chucks

High Precision Air Chucks Precision Workholding Solutions High Precision Air Chucks www..com Improve productivity and lower the cost of secondary machining operations..... through high concentricity. Holding close concentricity

More information

Hardware Fitting Accessories Bolts

Hardware Fitting Accessories Bolts Lever action flush bolt With slide Width: 19 mm Stroke (a): 25 mm 1 Flush bolt 1 Set of fastening material With lever arm Width: 19 mm Stroke (a): 18 mm 1 Flush bolt 1 Set of fastening material Stainless

More information