FAIRBANKS NIJHUIS 1590 SERIES SINGLE STAGE VERTICAL INLINE PUMP.
|
|
- Hannah Perkins
- 5 years ago
- Views:
Transcription
1 FAIRBANKS NIJHUIS 0 SERIES SINGLE STAGE VERTICAL INLINE PUMP
2 FAIRBANKS NIJHUIS 0 Series Single Stage Vertical Inline Pump Capacities to 00 GPM (,00 m/hr) Heads to 0 Feet ( m) Temperatures to 0 F (0 C) 0 Series Pumps Vertical Inline Close Coupled Pumps are specifically designed for mounting, in any position, directly in a pipe line. The suction and discharge nozzles are located on the same centerline 0º apart. Vertical pumps significantly reduce the space required; two pumps fit in the space of one. They are easy to maintain; simply remove the capscrews and the motor and bracket assembly is easily removed from the casing without disturbing the piping. The impeller is direct coupled to the motor shaft for easy maintenance to minimize impeller runout and reduce noise. Most pump parts, except for the casing, are 0% interchangeable with Fairbanks Nijhuis high quality, high production 00 and 0 Series pumps for speedy spare parts service. The inline casing has provisions for mounting an optional support base should the pump sit on the floor. Mechanical seals are provided as standard to prevent leakage around the shaft. A relief line is provided from the seal faces to the pump discharge for flushing and venting purposes. Suction Branch Design on Model 0 pumps prerotates suction liquid in the direction of pump impeller rotation. This concept minimizes pumping noise that is otherwise associated with more common short radius suction inlet designs. Each pump has been engineered and assurance tested to arrive at the proper velocities and entrance angles to ensure quiet operation. Fairbanks Nijhuis 0 Series pumps are available in sizes, offering a size and model precisely fitted to a wide range of head and capacity requirements. Look through this bulletin for additional details and specifications. 0 Split Coupled Inline Pump Fairbanks Nijhuis 0SC Vertical Inline Split Coupled Pumps are specifically designed for mounting directly in a pipe line. The High Strength Aluminum Split Coupling allows for the mechanical seal to be replaced without removing the motor. The Patented Integral Jacking Gland eases the changing of the mechanical seal making this repair chore faster and easier for the maintenance specialist. A carbon throttle bushing controls the flow of mechanical seal flushing while providing additional support for the Stainless Steel pump shaft. The Fairbanks Nijhuis 0SC Inline Pump comes in sizes, offering a size and model precisely fitted for a wide range of head and capacity requirements. Model 0 Model 0SC
3 Features and Options 0 Series Features Bronze Fitted Construction Bronze Shaft Sleeve Carbon Steel Shaft Dynamically Balanced Cast Impeller Casing Wearing Rings 0 Stainless Mechanical Seal with Buna-N, Ceramic and Carbon Parts Factory Hydro Test Standard Features. Back Pull-Out Casing with inline suction and discharge.. Case Wearing Ring prevents wear on casing and is inexpensively replaced. Impeller wear rings are optional.. Support Feet are cast integrally with the casing on Model 0 pumps. The pump thus can alternatively sit on the floor or bolt to an optional base if a foundation is preferred.. Precision Cast, Dynamically Balanced, Enclosed Impeller is keyed to the shaft extension and secured by a capscrew and washer. Gaskets are used to prevent leakage to shaft end.. Carbon Steel Shaft is designed for minimum deflection.. Mechanical Seal has carbon against Ceramic face for optimum hot water performance. Long life is assured with 0 stainless steel metal parts and Buna-N flexible elastomers (split seal optional). 0 Series Options All Iron Construction Stainless Steel Shaft Sleeve Impeller Wearing Ring(s) Suction and Discharge Companion Flanges Pump Base Certified Performance Test Data Consisting of Head Capacity and Power Readings Taken Over the Full Operating Range of the Pump Split Mechanical Seal. Factory Hydro Test guarantees casting and seal integrity. 0 Split Coupled Inline Pump Features Bronze Fitted Construction Stainless Steel Shaft High Strength Aluminum Coupling Dynamically Balanced Cast Impeller Casing Wear Rings 0 Stainless Steel Mechanical Seal with Buna-N, Ceramic and Carbon Parts Factory Hydro Test. Relief Line assures adequate venting of the seal chamber and lubrication of seal faces.. Bronze Shaft Sleeve prevents shaft wear and extends the entire length of the seal box. The shaft sleeve is slip fit over the shaft and then is keylocked. Shaft sleeve and impeller screw are sealed by O-ring gaskets to eliminate corrosion of the shaft by the pumped liquid. This standard feature eliminates the requirements for higher cost, special stainless steel shaft.. Standard JM Motor ( 0) HP provides low noise level pump operation. Special TCZ motor for above 0 HP. (JP motor used w/optional split seal). Volute Type Suction inlet prerotates suction liquid. 0 Split Coupled Inline Pump Options All Iron Construction Impeller Wear Rings Pump Base High Temperature Mechanical Seal Certified Performance Testing over the Full Operating Range of the Pump
4 Engineering and Dimension Details Pump Size X BW (MIN) -/" B -/ () " (0) " -/ A & B () " -/ C () " (0) -/" () -/" () " -/ A & B () " A () " B () " () " () " A & B () " A & B () " () " (0) " (0) " () " () " () " () " () " () " () " () " -/ () " () () -/ () -/ () -/ () () -/ () () () -/ () () -/ () () () () -/ () () -/ () -/ () -/ () -/ () -/ () () -/ (0) () () (0) (0) DC DE DH YY VD CASING JM JM JM JM TCZ TCZ FEET TAPPING -/ () -/ () -/ () -/ () -/ () -/ () -/ () -/ () () -/ () -/ () -/ () -/ () -/ () () -/ () -/ (00) -/ () -/ () -/ () () (0) -/ () -/ () -/ (). () () -/ () -/ () -/ () -/ () (0) -/ (0) -/ () -/ () -/ () -/ () -/ () -/ () -/ () -/ () -/ () -/ () -/ () -/ () -/ () -/ () () () () -/ () -/ (). (). () () N/A -/ () -/ N/A () (0) N/A -/ () () -/ -/ -/ () () () -/ -/ () () (0) -/ -/ () () () -/ -/ () () () -/ -/ -/ () () () -/ -/ () () () -/ -/ () () () -/ -/ () (0) () -/ -/ () () (0) -/ -/ () () () -/ -/ () (0) () -/ -/ (0) () () -/ -/ () () (0) -/ -/ () () (0) (0) () () () () () -/ -/ () () () -/ -/ () () () () (0) () -/ -/ () () () -/ -/ () () () -/ -/ () () () 0. -/ (0) () -/ () () -/ () () -/ () -/ () -/ () -/ () -/ () -/ () -/ () -/ () -/ () -/ () -/ () -/ () () -/ () () -/ () -/ () (0) (0) -/ () -/ () -/ () -/ (). (0). () NOTE NOTE NOTE NOTE NOTE SUCTION YY FRAME X BW DISCHARGE JM AND JP MOTOR FRAMES O.D.P. AG APPROX. T.E.F.C. EXP. PR. JM JM JM JM JM JM JM JM JM JM JM JM TCZ.. TCZ.. 0TCZ 0 0-/ 0TCZ 0 0-/ TCZ -/ -/ TCZ -/ -/ VD Notes:. All dimensions in inches and (mm).. Dimensions may vary ± /" ().. Not for construction purposes unless certified.. N/A = Not Applicable.. Conduit box is shown in approximate location. Dimensions are not specified as they vary with each motor manufacturer.. Suction and discharge flanges lb. ANSI Standard flat face.. Dimension BW is clearance required for servicing.. Normally not tapped. Optionally available [] /" UNC taps matching "- lb. flange drilling (." bolt circle).. Tapped [] /" UNC taps matching "- lb. flange (." bolt circle).. Tapped [] /" UNC taps matching "- lb. flange (.0" bolt circle).. Tapped [] /" UNC taps matching "- lb. flange (." bolt circle).. Tapped [] /" UNC taps matching "- lb. flange (." bolt circle). AG DH DC DE CASING FEET TAPPING CASING
5 Engineering and Dimension Details SUCTION YY X DISCHARGE HP DIMENSION TABLE FRAME P AG (0) () (0) (0) () () () () () (0) () () (0) 0 (0) (0) () (0) () (0) () () () () (0) () () () () 0 () () 0 () () () () () () Notes:. All dimensions in inches and (mm).. Dimensions may vary ± /" ().. Not for construction purposes unless certified.. N/A = Not Applicable.. Conduit box is shown in approximate location. Dimensions are not specified as they vary with each motor manufacturer.. Suction and discharge flanges lb. ANSI Standard flat face.. Normally not tapped. Optionally available [] /" UNC taps matching "- lb. flange drilling (." bolt circle).. Tapped [] /" UNC taps matching "- lb. flange (." bolt circle).. Tapped [] /" UNC taps matching "- lb. flange (.0" bolt circle).. Tapped [] /" UNC taps matching "- lb. flange (." bolt circle).. Tapped [] /" UNC taps matching "- lb. flange (." bolt circle). YD AG DH DC CASING FEET TAPPING DE Pump Size X DC DE DH YY VD CASING HP HP HP HP FEET TAPPING -/" -/ -/ -/ -/ -/ -/ SCB () () () () () () " -/ -/ -/ SC (0) () () () (0) () NOTE " -/ -/ -/ -/ -/ -/ SCA & B () () () () () () " -/ -/ -/ 0-/ -/ -/ SCC () () () () () () () NOTE " -/ -/ -/ -/ SC (0) () (0) () () (0) () -/" -/ -/ -/ SC () () (0) () () () () -/" -/ -/ -/ -/ -/ SC () () () () () () () " -/ -/ -/ -/ -/ -/ -/ SCA & B () () () () () () () " -/ -/ -/ -/ SCA () () () () () () () " -/ -/ -/ -/ -/ SCB () () () () () () () " -/ -/ -/ -/ -/ SC () () () () (0) () () " -/ -/ 0-/ -/ -/ SC () () () () () (0) () " -/ -/ 0-/ 0-/ -/ SCA & B () () () () () () () " -/ -/ -/ -/ -/ SCA & B () () () (0) () () () " -/ -/ -/ SC () () () () () () () NOTE " -/ -/ -/ -/ -/ SC (0) () () () () (0) () " -/ -/ -/ -/ SC (0) (00) () () () (0) () " -/ -/ 0-/ -/ -/ SC () () () () () () () " -/ -/ -/ -/ -/ SC () () () () () () () " -/ -/ -/ -/ SC () () () () () () (0) " 0-/ -/ SC () () () () () () (0) " -/ -/ -/ SC () (0) () () () () () " -/ -/ -/ -/ SC () () () (0) () () () " -/ -/ -/ -/ -/ SC () () () () () () () " -/ -/ -/ -/ -/ SC () () () () () () () " -/ -/ -/ -/ -/ -/ -/ SC () () () () () () (0) " SC () () -/ () -/ () -/ () () -/ ()
6 Performance Data 00 RPM 00 Individual performance curves should be checked for final selection. For selections not shown on this chart please refer to the factory HP " -/" HP " A 0 HP " B 0 HP 0 HP Low Flow, High Head High Flow, High Head High Flow, Low Head TOTAL DYNAMIC HEAD-FEET 0 00 HP -/ HP 0 HP HP HP 0 HP -/" " HP 0 HP 0 HP 0 HP 0 HP 0 HP " B " A 0 HP 0 HP 0 HP 0 HP " C " A -/ HP HP " B " A " B 0 HP HP 0 HP HP HP -/ HP HP 0 -/ HP 0 00 RPM Enclosed Impeller CAPACITY-G.P.M. TOTAL DYNAMIC HEAD-FEET / HP HP -/ HP / HP " -/" " A " B " B " A " A " A " C " B -/" B " A " " HP HP -/ HP HP " HP HP -/ HP " -/ HP " " HP HP HP -/ " HP -/ -/ HP HP HP -/ HP HP HP 0 HP " B HP 0 HP -/ HP " 0 HP " 0 HP " HP HP 0 HP " HP 0 HP " " HP 0 HP CAPACITY-G.P.M. 0 HP " " HP 0 HP HP 0 HP 0 HP HP " 0 HP HP 0 HP 0 HP HP 0 RPM Enclosed Impeller HP 00 HP " RPM Individual performance curves should be checked for final selection. For selections not shown on this chart please refer to the factory. Low Flow, Low Head Low Flow, High Head High Flow, Low Head High Flow, High Head
7 Performance Data 000 RPM Individual performance curves should be checked for final selection. For selections not shown on this chart please refer to the factory. 0 0 " A " A " " A -/" Low Flow, High Head High Flow, High Head 0 " B High Flow, Low Head 0 " C HEAD (METERS) 0 0 " " " B 0 -/" 0 " B " A " B 000 RPM 0 0 FLOW (M /HR) 0 RPM Individual performance curves should be checked for final selection. For selections not shown on this chart please refer to the factory. Low Flow, Low Head Low Flow, High Head 0 -/" " A " A " B " B -/" B " A " B " -/" 0 " A " A " " B " B " " " " " High Flow, Low Head High Flow, High Head 0 " " HEAD (METERS) 0 " " " " 0 0 " C " " " " 0 RPM FLOW (M /HR)
8 Engineering Specifications 0 Series Specifications The contractor shall furnish (and install as shown on the plans) Fairbanks Nijhuis TM Model 0/0SC vertical close coupled inline back pull-out centrifugal pumps size x x of (bronze fitted) (all bronze) (all iron) construction. The suction and discharge flanges shall be located on a common CL 0º apart for mounting inline. Each pump shall have a capacity of GPM at ft. total head, with a temperature of ºF, specific gravity. Each pump is to be furnished with a mechanical seal with all metal parts to be 0 stainless steel with Buna-N elastomers, Ceramic seat and carbon washer. A bypass line must be provided between the seal faces and the discharge flange to assure adequate venting of the seal chamber and to provide lubrication. Impellers are to be dynamically balanced and keylocked to the shaft. Model 0/0SC pumps to include a volute type casing suction branch to minimize pumping noise. The unit must be equipped with (bronze) (stainless steel) shaft sleeve, keylocked, that extends the length of the seal box. Pump shaft extension shall be O-ring sealed from the pumped liquid. Pump casing shall have a case wearing ring (impeller wearing rings). Each pump is to be close coupled to a standard NEMA-JM HP phase Hertz volt RPM (drip-proof) (total enclosure) (hazardous location) motor up to 0 HP and special TCZ frame motor for HP above 0. Pump Part Casing Impeller Shaft (0) Shaft (0SC) Case Wearing Rings Bushing (0SC Only) Sleeve Bracket Mechanical Seal (STD) Washer Seat Elastomer Metal Parts Spring Materials of Construction Bronze Fitted Cast Iron ASTM A Bronze ASTM B Carbon Steel Per Motor Mfg. Stainless Steel ASTM A Type Bronze ASTM B Carbon Graphite Matrix Bronze ASTM B Cast Iron ASTM A Carbon Ceramic Buna-N 0 SS 0 SS Limitations Maximum Limitation Based on Standard Materials and Pumping Clear Water Speed 00 RPM RPM 0 0 RPM 0 Horsepower 00 RPM 0 TCZ FRAME MOTORS RTF Temperature ºF Standard /Optional 0 Hydrostatic Test Pressure PSI Case Working Pressure PSI (All or Any Part Can Be Suction Free) 0 FAIRBANKS AVENUE, KANSAS CITY, KANSAS Because we are continuously improving our products and services, Pentair reserves the right to change specifications without prior notice. FM-0-0/0/ 0 Pentair Ltd. All Rights Reserved.
Series 80 In-Line Mounted Centrifugal Pumps
Bulletin B-G Bell & Gossett Series In-Line Mounted Centrifugal Pumps Applications Hydronic Heating & Cooling Systems Industrial Process General Service Pressure Boosting Advantages Close Coupled Space
More informationCENTRIFUGAL PUMPS FRAME MOUNT 13" FEATURES
FEATURES Volute: Cast iron for heavy-duty service; back pullout design; can be rotated for ease of installation; 6 x 8-13 and 8 x 10-13 are split volutes for reduction in radial bearing load Impeller:
More information420 SERIES REPAIR PARTS INDEX
SECTION 420P PAGE 1 SUPERSEDES 420P PAGE 1 420 SERIES REPAIR PARTS INDEX READ AND UNDERSTAND THE PUMP AND MOTOR INSTRUCTIONS BEFORE ATTEMPTING TO INSTALL, DISASSEMBLE OR REPAIR THE PUMP SECTION 420P PAGE
More informationMATERIAL COMBINATION NUMBER 2: Corrosive environment requiring harder, wear-resistant seating faces and resistance to dezincification.
Cast Iron Slide Gates Spec Sheet General The contractor shall furnish and install the following cast iron slide gate assemblies as listed on the Gate Schedule and detailed on the manufacturer s drawings.
More information380 SERIES REPAIR PARTS INDEX
SECTION 380P PAGE 1 SUPERSEDES 380P PAGE 1 380 SERIES REPAIR PARTS INDEX READ AND UNDERSTAND THE PUMP AND MOTOR INSTRUCTIONS BEFORE ATTEMPTING TO INSTALL, DISASSEMBLE OR REPAIR THE PUMP SECTION 380P PAGE
More informationTYPE 3740 WET RUNNING CARTRIDGE SPLIT SEAL Technical Specification
A Mating Ring B Mating Ring Adapter Assy. C Sealing Element Gasket D Sealing Element Strip E Sealing Element O-ring F Set Screw G Primary Ring H Retaining Ring I Spring Adapter Assy. Set J O-ring (Split)
More informationInstallation Instructions
Installation Instructions Durametallic PSS III Split Seal Experience In Motion While the PSS III has been designed for rugged industrial application and ease of installation, it does require assembly in
More informationSubmittal Data Sheet Wilo MVI - Vertical Multistage Pumps
Wilo MVI Project: Engineer: Contractor: Submitted By: Date: Approved By: Date: Tag # Model # Flow Head HP Cycle Phase Voltage RPM Hz H [ft] ηp [%] P [hp] 7 7.......7..9.......................... MVI -
More information420 SERIES. TWO Stage Vertical and
420 SERIES TWO Stage Vertical and HORIZONTAL SPLIT CASE PUMPS REPAIR PARTS INDEX NOTE! Read and understand the pump and motor instructions before attempting to install, disassemble or repair the pump.
More informationMUNICIPAL INDUSTRIAL CONSTRUCTION / RENTAL AGRICULTURE. SF Series Submersible Solids-Handling Pumps
MUNICIPAL INDUSTRIAL CONSTRUCTION / RENTAL AGRICULTURE SF Series Submersible Solids-Handling Pumps A History of Innovation 2 Gorman-Rupp has been revolutionizing the pumping industry since 1933. Over the
More informationMAINTENANCE CLEANING. MECHANICAL SEAL REPLACEMENT Refer to figures 1 and 2. SHIM ADJUSTMENT
Please read and save this Repair Parts Manual. Read this manual and the General Operating Instructions carefully before attempting to assemble, install, operate or maintain the product described. Protect
More informationThis specification describes the minimum requirements for piping systems for the following service:
201/01/13 1/ 1.0 APPLICATION This specification describes the minimum requirements for piping systems for the following service: Service Air Design Conditions Operating Conditions Blast Air (see Note 1)
More informationBooster Pumping Station 115 Booster Pump Procurement
Madison Water Utility Tom Heikkinen General Manager 119 E. Olin Avenue Alan L. Larson PE, BCEE Principal Engineer Madison, Wisconsin 53713 Telephone: 608 266-4653 FAX: 608 266-4426 email: allarson@cityofmadison.com
More informationSubmittal Packages Detailed with Items and Reviewers
Submittal Packages Detailed with Items and Reviewers Tenochca Upgrades Project # 1 San Diego State University 00 Campanile Drive San Diego, CA 918 Tel: 619-94-740 Fax: 0079-1116-0 Circulating Pump Author
More information4.4 PUMP MAINTENANCE MODELS: DB, DC, DF, DG, DJ, DL
4.4 PUMP MAINTENANCE MODELS: DB, DC, DF, DG, DJ, DL 4.4.1 EXPLODED VIEW DRAWING REF. QTY. DB DC DF DG DJ DL DESCRIPTION PART # 1 1 ADAPTOR FRAME 034007 2 12 LOCK WASHER 3/8 x 1/8 S.S. 034004 3 12 HEX HEAD
More informationThis specification describes the minimum requirements for piping systems for the following service:
SPEC-3501 1/ 1.0 APPLICATION This specification describes the minimum requirements for piping systems for the following service: Instrument Air Design Conditions 150 PSIG @ 180 F Operating Conditions 125
More informationMEDIUM DUTY CAST IRON SLIDE GATES SERIES 20-10C
MEDIUM DUTY CAST IRON SLIDE GATES SERIES 20-10C Revised October 2007 Armtec reserves the right to alter designs. General The Armtec Sluice Gate is a quality and highly economical gate for a variety of
More informationWater Circulation Pumps & Circulators PERFORMANCE CURVES. CI Pumps. FI Pumps. Taco Curve Book B
Water Circulation Pumps & Circulators PERFORMANCE CURVES FI Pumps CI Pumps Taco Curve Book 300-2.5B Effective April 27, 2017 (Supersedes March 31, 2012 CAPACITY IN LITERS/SEC FLOW IN GALLONS PER MINUTE
More information4.2 - PUMP MAINTENANCE MODELS: AC, AS, WC, WS
4.2 - PUMP MAINTENANCE MODELS: AC, AS, WC, WS 4.2.1 - EXPLODED VIEW DRAWING REF NO. 1 2 4 QTY 3 1 1.5 5 ¾ HP HP HP HP HP DESCRIPTION PART # 1 CASE 1.25 x 1 NPT 018266 1 CASE 1.25 X 1 NPT 018268 1 CASE
More informationThis specification describes the minimum requirements for piping systems for the following service:
SPEC-3004 1/7 1.0 APPLICATION This specification describes the minimum requirements for piping systems for the following service: Service Water Design Conditions Operating Conditions 10 PSIG @ 33 o F to
More informationA cost effective, compact and reliable PWM drive for 1/4 through 1 HP DC applications
A cost effective, compact and reliable PWM drive for 1/4 through 1 HP DC applications The Micro 100 Drives have been designed with a Pulse Width Modulated (PWM) regulator to produce clean DC current to
More informationPARTS LIST SERIES 5200
File No. 6052.120 Date: January 6, 2003 Supersedes: 6052.120 Date: June 1, 1996 SUMP PUMP NEW DESIGN 5200 SUMP PUMP PARTS IDENTIFICATION ITEM DESCRIPTION PAGE ITEM DESCRIPTION PAGE ITEM DESCRIPTION PAGE
More information2-Inch Thermoplastic Dewatering Pumps Refer to pump manual for General Operating and Safety Instructions.
Specifications Information and Repair Parts Manual 3824-99, 3825-99 & 382A-99 Please read and save this Repair Parts Manual. Read this manual and the General Operating Instructions carefully before attempting
More informationPhD Inline Vortex. Performance Specifications Accuracy. Operating Specifications
Description The Vortex PhD vortex shedding flowmeter measures process fluid flow by detecting the frequency at which vortices are shed from an obstruction in the process fluid line (the bluff body). A
More informationTYPE 3740/3740D WET/DRY RUNNING CARTRIDGE SPLIT SEAL
1 Foreword These instructions are provided to familiarize the user with the seal and its designated use. The instructions must be read and applied whenever work is done on the seal, and must be kept available
More informationThis specification describes the minimum requirements for service water piping systems (ie: cooling water, process water, etc.), located on surface.
SPEC-3500 1/9 1.0 PURPOSE This specification describes the minimum requirements for service water piping systems (ie: cooling water, process water, etc.), located on surface. Note: This specification does
More information400 SERIES GRINDER PUMPS 41502, 42202,43302, AND MODELS
Section: MOYNO 500 PUMPS Page: 1 of 6 Date: March 1, 1998 SERVICE MANUAL MOYNO 500 PUMPS 400 SERIES GRINDER PUMPS 41502, 42202,43302, AND 44402 MODELS DESIGN FEATURES Housing: Cast iron Pump Rotor: Chrome
More informationStargrip series 3000 Mechanical Joint Wedge Action Restraint for Ductile Iron Pipe
Stargrip series 3000 Mechanical Joint Wedge Action Restraint for Ductile Iron Pipe INFORMATION The Stargrip Mechanical Joint Restraint System is a unique product with a proven design that provides an exceptional
More informationUL / FM E-1 FIRE PROTECTION PRODUCTS INDICATOR POST FEATURES. *Applies to "ORDER LENGTH" codes B through F; code A has 22" adjustment.
UL / FM MUELLER Indicator Post are used in fire protection systems and perform several functions. The Indicator Post provides a means to operate a buried or otherwise inaccessible valve. Also, the Indicator
More informationTYPE 3740XL EXTRA LARGE WET RUNNING CARTRIDGE SPLIT SEAL
1 Foreword These instructions are provided to familiarize the user with the seal and its designated use. The instructions must be read and applied whenever work is done on the seal, and must be kept available
More informationElectro-Magnetic Flowmeters COPA-XE
Data Sheet Electro-Magnetic Flowmeters COPA-XE 10DX4311 Flowmeter system utilizes a smart microprocessor converter System accuracy of ± 0.5% of rate Field configurable via integral pushbuttons, eliminates
More informationLowara. Centrifugal pumps with open impeller and flanged connections. SHO Series MARKET SECTORS CIVIL, INDUSTRIAL.
Centrifugal pumps with open impeller and flanged connections SHO Series MARKET SECTORS CIVIL, INDUSTRIAL. APPLICATIONS Industrial washing machines. Commercial dishwashers. Washing of metal parts, surface
More informationFeatures. Continuous Duty Cycle Actuators
Features Predictable life. Continuous operation. Oil lubricated. High mechanical and thermal efficiency 2 models available. Capacity 3,500 to 27,000 pounds Available with C-Face motor adaptors and speed
More informationAppendix E Part Details for the PT20 with Standard Bypass Valve
Appendix E Part Details for the PT0 with Standard Bypass Valve 8 ( ft lb) Part Number Locknut Wrench ( ft lb) 0 8 0 Note: The PT0 is shown below. All parts for the PT0 are the same except for the rotor
More informationInstallation Instructions
Installation Instructions XLC Generation 2 Self-aligning split bearing Experience In Motion 1 Equipment Check 1.1 Follow plant safety regulations prior to equipment disassembly: Lock out motor. Wear designated
More informationEliminate Corrosion & Electrolysis Forever!
Eliminate Corrosion & Electrolysis Forever! SIMSITE Rings Casing Rings and Wear Rings Corrosion Resistant Light Weight Prevents Electrolysis Prevents Damage to the Casing Non-Sparking Non-Galling Allows
More informationReliance SG800 Series Steel Water Gage Valves
Installation, Operation, & Maintenance Instructions R500.541D1 10/16/2016 Reliance SG800 Series Steel Water Gage Valves Note: Design variations in Steel Water Gage Valves necessitate typical illustrations,
More informationAF-4 Grooved Flange Adapter
SUBMITTAL INFORMATION PROJECT NAME: ENGINEER: CONTRACTOR: SPEC. SECTION: MEMBER FEATURES & ADVANTAGES Designed for connecting ANSI/AWWA C110/A21.10 and ASME/ANSI B16.1 Class 125/ flanged end components
More informationThe MUELLER method of making a main to service connection using the MUELLER E-5 Small Drilling Machine. The main is drilled out under pressure.
MUELLER SMALL DRILLING MACHINES 2.1 Rev. 9-09 MUELLER Co. manufactures several different small drilling machines for drilling holes from 7/16" to 2" in all types of pipe. Machines are available in hand
More information5000 Series Single Impeller Firefighter
5000 Series Single Impeller Firefighter Pump made in Australia & fitted to genuine brand name engines SERVICING INSTRUCTIONS WARNING: ALL ELECTRICAL WORK TO BE PERFORMED BY SUITABLY QUALIFIED ELECTRICAL
More informationSpecification for Horizontal End Suction Centrifugal Pumps for Chemical Process
ASME B73.1-2012 [Revision and Consolidation of ASME B73.1-2001 (R2007) and ASME B73.5M-1995 (R2007)] Specification for Horizontal End Suction Centrifugal Pumps for Chemical Process AN AMERICAN NATIONAL
More informationRodney Hunt. A GA Industries Company Glydaseal Gates
Rodney Hunt A GA Industries Company Glydaseal Gates GUIDE BRONZE GUIDE BAR FRAME NUT POCKET SEAT FACING RESILIENT INVERT SEAT DISC GUIDE BAR ADJUSTMENT BOLT WITH LOCK NUT GUIDE BAR ATTACHING BOLT The Glydaseal
More informationSwivel Hoist Ring RIGGING ACCESSORIES. Color coded to distinguish between UNC (Red) and Metric (Silver) thread types.
RIGGING ACCESSORIES Color coded to distinguish between UNC (Red) and Metric (Silver) thread types. Available in UNC and Metric thread sizes. UNC threads available in sizes from 800 pounds to 100,000 pounds,
More informationUII Pump Parts
0-4-0-4-UII Pump Parts. Page 66 95-0305 September 009 Parts Lists 0-4-0-4-UII Pump Parts QTY. PER PUMP PART NOTES 0-U Pump Body See Note 0-U Pump Body with Flush See Note 4-U Pump Body See Note 4-U Pump
More informationINSTRUCTION MANUAL AND PARTS LIST MODEL 14-10
VERTICAL BAND SAWS INSTRUCTION MANUAL AND PARTS LIST MODEL 1-10 DAKE/PARMA WHEN ORDERING PARTS GIVE COMPLETE SERIAL NUMBER OF MACHINE GIVE PART NUMBER AND NAME GIVE AMOUNT REQUIRED Unless the above data
More informationRepair Manual 12 PL PILOT
Repair Manual 12 PL PILOT 12 PL PILOT REPAIR MANUAL INDEX Introduction... 1 Elastomer Materials... 2 Disassembly... 3 Assembly... 7 Testing... 11 NOTE: We reserve the right to modify or change, without
More informationSF Series Submersible Solids-Handling Pumps. / /
MUNICIPAL INDUSTRIAL CONSTRUCTION / RENTAL AGRICULTURE SF Series Submersible Solids-Handling Pumps A History of Innovation 2 Gorman-Rupp has been revolutionizing the pumping industry since 1933. Over the
More informationThe MUELLER method of making a main to service connection using the MUELLER E-5 Small Drilling Machine. Hand or power. kpa/34.
MUELLER SMALL DRILLING MACHINES 2.1 Shaded area indicates change Rev. 9-09 MUELLER Co. manufactures several different small drilling machines for drilling holes from 7/16" to 2" in all types of pipe. Machines
More informationOPTIFLUX 5000 Technical Datasheet
OPTIFLUX 5000 Technical Datasheet Electromagnetic flowmeter in flanged version Exceptional long-term stability and accuracy For highly aggressive and abrasive fluids Fully vacuum-resistant with high-tech
More informationSECTION STEEL LIGHTING STANDARDS. 1. Electrical conduit and fittings; Section
02760-1 of 5 SECTION 02760 STEEL LIGHTING STANDARDS 02760.01 GENERAL A. Description Steel lighting standards shall include, but not necessarily be limited to, furnishing and installing steel lighting poles,
More informationThe Redi-Flange Method. How It Works. Services. Engineering & Costing Assistance
... g n ldi ng... e i W No hread ing! T oov o N Gr o N The Redi-Flange Method Redi-Flange is a method of joining valves, fi ttings and equipment with integral fl anged ends to plain-ended pipe, with all
More informationWATER METERS M SERIES WATER METERS INSTALLATION, OPERATION AND MAINTENANCE GUIDE METAL M SERIES WATER METER PLASTIC M SERIES WATER METER
WATER METERS M SERIES WATER METERS INSTALLATION, OPERATION AND MAINTENANCE GUIDE METAL M SERIES WATER METER PLASTIC M SERIES WATER METER INTRODUCTION M SERIES WATER METERS INDUSTRY S SMALLEST WATER METERS
More informationCast Iron Junction Boxes
Cast Iron I. Purpose of Enclosure Enclosures are used to protect personnel against accidental contact with enclosed electrical devices or connections and to protect the enclosed devices or connections
More informationB34 Series Regulator Commercial and Industrial Regulator
B34 Series Regulator Commercial and Industrial Regulator Appropriate for many commercial and industrial uses such as gas engines, burners, furnaces and boilers. The rapid response of the B34 is particularly
More informationRecommended fire spare parts book. Parts lists
Recommended fire spare parts book Parts lists File No: f0.58 Date: june 10, 2014 Supersedes: f0.58 Date: february 20, 2014 contents file name file number page Series 4600 hsc fire recommended part list
More informationType XTSR71 Sizes
(Page 1 of 13) s 494-5258 Type XTSR71 s 494-5258 Figure 1 Thomas XTSR71 Coupling 1. General Information 1.1 Thomas Couplings are designed to provide a mechanical connection between the rotating shafts
More informationINSTRUCTION MANUAL Q-HYDRAULIC
Dat: 15.04.02 No: 94-BA 5039E/1b TABLE OF CONTENTS Part III 3.0 Type code explanation 3.1 Service connections 3.2 Impeller clearance adjustment 3.2.1 Wear of wearing parts 3.2.2 General notes to adjustment
More informationREPAIR CLAMP PARTS H fax: MULTIPLIER
REPAIR CLAMP PARTS Part Number Component Description Model Number Product Size List Price Unit V001 Neoprene Sheet Gasket AS All Sizes Square Inch V002 Waffle Pattern Gasket (NBR) AS All Sizes Square Inch
More informationParts List 4 MODEL T-18 and T-27 Mark II Turbo-Meters
MP-1070A Rev. 9 Invensys Energy Metering 80 Liberty Boulevard DuBois, PA 15801 Telephone (814) 371-8000 FAX (814) 375-8460 Parts List 4 Model T-18 and T-27 Mark II Turbo-Meter Parts List 4 MODEL T-18 and
More informationHow to Identify a PBM VALVE SERIES
How to Identify a PBM VALVE SERIES Series 0 (SP, DP, MP) 1. If it is a manual valve, the handle generally would be made of a cast iron or cast bronze. 2. If it is a manual valve, the stem at the very top
More informationService Instruction No. 71 INSTALLATION AND SERVICE INSTRUCTIONS HD SERIES PUMPS INDUSTRIAL DUTY MODELS
Service Instruction No. 71 INSTALLATION AND SERVICE INSTRUCTIONS HD SERIES PUMPS INDUSTRIAL DUTY MODELS v 1.2 Page 1 of 32 Read Manual before operating or working on a Tuthill HD pump. Table Of Contents
More informationTYPE 5610 & 5610Q SINGLE O-RING CARTRIDGE SEAL
1 Foreword These instructions are provided to familiarize the user with the seal and its designated use. The instructions must be read and applied whenever work is done on the seal, and must be kept available
More informationTYPE 3710 CARTRIDGE SPLIT SEAL
1 Foreword These instructions are provided to familiarize the user with the seal and its designated use. The instructions must be read and applied whenever work is done on the seal, and must be kept available
More informationFisher 1052 Size 20 Diaphragm Rotary Actuator with H Mounting Adaptation
Instruction Manual 1052 Size 20 Actuator (H) Fisher 1052 Size 20 Diaphragm Rotary Actuator with H Mounting Adaptation Contents Introduction... 1 Scope of Manual... 1 Description... 2 Specifications...
More informationTerraBrute CR (4-12 ) Pipe Installation Guide
1.0 Introduction TerraBrute CR is an integral-bell restrained-joint PVC pipe that meets the performance requirements of AWWA C900 (1). It has a slight modification that allows the joints to be locked for
More informationInstallation, Operation, and Maintenance Manual Model: PW VSP 800
Installation, Operation, and Maintenance Manual Model: PW VSP 800 TABLE OF CONTENTS Introduction Introduction INTRO 1 Safety INTRO 1 Handling and Installation Handling Instructions HANDLE 1 Installation
More informationOPERATION AND MAINTENANCE FOR MODEL MRV050A REVERSIBLE
OPERATION AND MAINTENANCE FOR MODEL MRV050A REVERSIBLE MANUAL AIR MOTOR 04666770 Edition 1 April, 1999 IMPORTANT SAFETY INFORMATION ENCLOSED. READ THIS MANUAL BEFORE OPERATING TOOL. FAILURE TO OBSERVE
More information25000 Series Lo-T TM Butterfly Control Valve Instructions
November 2001 25000 Series Lo-T TM Butterfly Control Valve Instructions Instruction No. 25.1:IM PRELIMINARY STEPS Before installation, note the flow direction arrow on the valve body. The flow should enter
More informationINSTALLATION AND SERVICE INSTRUCTIONS HD SERIES PUMPS INDUSTRIAL DUTY MODELS
Service Instruction No. 71 INSTALLATION AND SERVICE INSTRUCTIONS HD SERIES PUMPS INDUSTRIAL DUTY MODELS v 1.5 Page 1 of 46 WARNING WARNING Read Manual before operating or working on a Tuthill HD pump.
More informationTABLE OF CONTENTS SERIES SPINDLES Cartridge Block Belt-Driven Motorized GILMAN SPINDLE SYSTEMS... 4 PRODUCT FEATURES...
spindles TABLE OF CONTENTS GILMAN SPINDLE SYSTEMS.... 4 PRODUCT FEATURES.... 5 ORDERING INSTRUCTIONS.... 6-8 1250 SERIES SPINDLES Cartridge.... 10 1875 SERIES SPINDLES Plain Cartridge.... 11 Positioning
More informationPipe Restraints and Adapter Flanges. Section U. For PVC, Ductile Iron and Steel Pipe. 09/2017 Web Revision
DQS Inc. THE FORD METER BOX COMPANY, INC. CERTIFIED TO ISO 9001:2015 10004466 Section U 09/2017 Web Revision 11-29-17 Restraints and Adapter Flanges For PVC, Ductile Iron and Steel Contents Applications
More informationInstallation Instructions
Installation Instructions XLC Series Self-aligning split bearing Experience In Motion 1 Equipment Check 1.1 Follow plant safety regulations prior to equipment disassembly: Lock out motor. Wear designated
More informationSplit case double suction centrifugal pump. Technical data Serie: DPAS C
Split case double suction centrifugal pump Technical data Serie: DPAS C Table of Contents 1 Introduction 1.1 Fields of Application... 1. Pumped Liquids... 1.3 Design... 1. Bearings... 1.5 Shaft Seal...
More informationANDERSON GREENWOOD SAFETY SELECTOR VALVE
A dual pressure relief device system that provides a safe, efficient method of switching from an active PRV to a standby, maintaining system overpressure protection FEATURES GENERAL APPLICATION Safety
More informationH4670/42192 Submersible Trash Pump
SERVICE MANUAL H4670/42192 Submersible Trash Pump Serial Code GLW Read and understand all of the instructions and safety information in this manual before operating or servicing this tool. 99916070 REV
More informationWATERFLUX 3000 Quick Start
WATERFLUX 3000 Quick Start Electromagnetic flow sensor The documentation is only complete when used in combination with the relevant documentation for the signal converter. KROHNE CONTENTS WATERFLUX 3000
More informationSIGHT GLASS. Sight glass components allow operators to safely observe processes inside tanks, pipes, reactors and vessels.
SIGHT GLASS Sight glass components allow operators to safely observe processes inside tanks, pipes, reactors and vessels. SIGHT GLASS Sight flow indicator. A sight flow indicator is used in process pipelines
More information380 SERIES REPAIR PARTS INDEX. NOTE! Read and understand the pump and motor instructions before attempting to install, disassemble or repair the pump.
380 SERIES REPAIR PARTS INDEX NOTE! Read and understand the pump and motor instructions before attempting to install, disassemble or repair the pump. Part # A-03-222 2014 Pentair Ltd. 07/31/14 SECTION
More informationpneumatic c-ring tool
pneumatic c-ring tool hc5 HC5 WARNINGS! Always read tool manual before operating tool. Always wear safety glasses when operating or while in the area where a tool is being used. When test cycling tool
More information3.1 MUELLER LARGE DRILLING MACHINES
MUELLER LARGE DRILLING MACHINES 3.1 Shaded area indicates change Rev. 1-09 Large Drilling Machines are used for making 2" to 24" lateral connections on water mains under pressure. These machines are available
More information3.1 MUELLER LARGE DRILLING MACHINES
MUELLER LARGE DRILLING MACHINES 3.1 Shaded area indicates change Rev. 1-09 Large Drilling Machines are used for making 2" to 24" lateral connections on water mains under pressure. These machines are available
More informationHeavy-Duty Stuffing Boxes
SHAFT SEALING SYSTEMS Heavy-Duty Stuffing Boxes E Designed for Sealing: Stern Tubes, Bulkheads, Rudder Ports E Air Seal for Maintenance at Sea E Water & Grease Service Options E Bronze (Standard) or Aluminum
More informationFIRE PROTECTION PRODUCTS
FEATURES Rev. 7-11 Mueller Indicator Post are used in fire protection systems and perform several functions. The Indicator Post provides a means to operate a buried or otherwise inaccessible valve. Also,
More informationAFB (AIR FAN BEARING) INSTALLATION GUIDE
654 AFB (AIR FAN BEARING) INSTALLATION GUIDE AFB PARTS Bearing Housing - Secured together with two 3/8 x 1.25 in. Cap Screws Black Wiper Seals - Secured together with O-ring cord (Subsequently depicted
More informationSERVICE INSTRUCTIONS
SERVICE INSTRUCTIONS TURBINE MIXER MODEL TO, TCL & TC DRIVE SERIES F MANUAL NO. 05-47775 REVISED 03/2016 CUSTOMER: P.O. NO.: ITEM NO.: MIXER MODEL NO.: MIXER SERIAL NO.: DRIVE SERIES & SIZE: INPUT ASSEMBLY
More informationEN 1092 PN 10 EN 1092 PN 16 JIS B K ANSI B16.5 Class 150 ANSI B16.47 Class 150 BS 10 Table D
HG EN 1092 PN 10 EN 1092 PN 16 JIS 2238 10K ANSI 16.5 Class 150 ANSI 16.47 Class 150 S 10 Table D Stafsjö s knife gate valve HG is a bi-directional valve, particularly well suited for severe operating
More informationSeries 4310 A Partnership for Success Series Battioni P agani Battioni Pagani Series Pompe natv ac.c om
Vacuum Pumps & Blowers 4310 Blower A Partnership for Success Commercial duty Battioni Pagani Battioni Pagani Pompe Vacuum pumps & Blowers Vacuum / Pressure Pumps MEC 2000-4000 607 - National Vacuum Equipment
More informationFord Water Meter Couplings & Accessories
Section H 2/2001 Ford Water Meter Couplings & Accessories The Ford Meter Box Co., Inc. 775 Manchester Avenue, P.O. Box 443, Wabash, Indiana, USA 46992-0443 Telephone: 260/563-3171 FAX: 1-800-826-3487 Overseas
More informationTPHK Series. Immersible Pump
Series Immersible Pump Contents General Data Performance Range Sectional Drawing Performance Curves/Technical Data T T T T Series Immersible Pump Hz Power:. -. kw Head: Up to M Flow: Up to L/min Hz Power:.
More informationVALVTECHNOLOGIES, INC. INSTALLATION, OPERATIONS & MAINTENANCE MANUAL STEAM CHOKE VALVES
VALVTECHNOLOGIES, INC. INSTALLATION, OPERATIONS & MAINTENANCE MANUAL STEAM CHOKE VALVES Page STEAM CHOKE VALVES The Valvtechnologies steam choke is designed for the harsh conditions associated with steam
More informationSPECIFICATION STEEL COUPLING MODEL 411
Sleeve Bolt Nut Follower Gasket 1/2 2 TWO BOLT 3 12 HIGH STRENGTH 2 12 SMALL O.D. 14 60 LARGE O.D. APPLICATIONS Typical Uses Joining plain-end pipe of same outside diameters Replace split or excessively
More informationAGUB Instrument and Meter Enclosures Explosionproof, Dust-Ignitionproof Furnished with aluminum body and solid or window cover.
AGUB Instrument and Meter Enclosures Furnished with aluminum body and solid or window cover. Class I, Division 1 and, Groups B, C, D Application To pull or splice wires and/or to mount and enclose electrical
More informationNEMO BO/BS Pump with Hopper in Block Construction and Flanged Drive
NEMO BO/BS Pump with Hopper in Block Construction and Flanged Drive The ideal pump for crumbly media in a compact design. tabposition1contentblockidentifiertab-6018-1-605-0content Universally applicable
More informationSECTION TRANSFORMERS
SECTION 16460 - TRANSFORMERS PART 1 - GENERAL 1.01 RELATED DOCUMENTS A. General: Drawings and general provisions of the Contract, including General and Supplementary Conditions and Specification Section
More informationSPECIFICATION: ALUMINUM SLIDE GATES
SPECIFICATION: ALUMINUM SLIDE GATES PART 1 GENERAL 1.1 The Slide gates shall be manufactured from Aluminum material as specified and shall be Flange back type suitable for wall thimble mounting and generally
More informationReliance SG777 Series Steel Water Gage Valves
Installation, Operation, & Maintenance Instructions R500.SG777 10/16/2016 Reliance SG777 Series Steel Water Gage Valves Note: Design variations in Steel Water Gage Valves necessitate typical illustrations,
More information4456H TYPE 1 OWNERS MANUAL
4456H TYPE 1 OWNERS MANUAL G12-545 09/25/09 SAFETY INSTRUCTIONS This is an industrial component. Only a qualified systems integrator should be allowed to design it into a system. The integrator must determine
More informationInstallation Instructions
Installation Instructions Circpac MD Split Segmented Circumferential Gas Seal Experience In Motion 1 Equipment Check and Seal Preparation 1.1 Refer to Figure 1 for sleeve/shaft and equipment requirements.
More informationSECTION IV. Covers Trough Ends Trough Conveyor Screws Discharges Inlets Special Features
Special Features SECTION IV SPECIAL FEATURES SECTION IV Covers...109 Trough Ends...110 Trough...111 Conveyor Screws...114 Discharges...119 Inlets...120 Special Features The information presented in this
More informationEchotel Model 910 Ultrasonic Level Switch
Echotel Model 910 Ultrasonic Level Switch D E S C R I P T I O N Echotel Model 910 Level Switches utilize ultrasonic contact technology for measuring level in clean liquid applications. The dual conduit
More information