SPECIFICATIONS...02-B2 and 03-B2 TECHNICAL DATA...04-B2 SPECIAL FEATURES...05-B2

Size: px
Start display at page:

Download "SPECIFICATIONS...02-B2 and 03-B2 TECHNICAL DATA...04-B2 SPECIAL FEATURES...05-B2"

Transcription

1 0- Table of Contents Series FF0 Series FF Series FT Series FF00 Series FF0 Series FT0 SECTION PGE Series FF0, FF, FT, FF00, FF0, and FT0 SPECIFICTIONS...0- and 0- TECHNICL DT...0- SPECIL FETURES...0- Series FF0 TYPICL DETILS...0- thru - WINDLOD CHRTS...- and - DEDLOD CHRTS...- Series FF and FT TYPICL DETILS...- thru - WINDLOD CHRTS...- and - DEDLOD CHRTS...- Series FF00 TYPICL DETILS...- thru - WINDLOD CHRTS...0- and - DEDLOD CHRTS...- Series FF0 and FT0 TYPICL DETILS...- thru - WINDLOD CHRTS...0- and - DEDLOD CHRTS...- CCESSORIES ND GLZING GSKETS (LL SYSTEMS)...- thru - MISCELLNEOUS FRMING...- thru - Due to the diversity in state/provincial, local, and federal laws and codes that govern the design and application of architectural products, it is the responsibility of the individual architect, owner, and installer to ensure that products selected for use on projects comply with all applicable building codes and laws. U.S. luminum exercises no control over the use or application of its products, glazing materials, and operating hardware, and assumes no responsibility thereof. The rapidly changing technology within the architectural aluminum products industry demands that U.S. luminum reserve the right to revise, discontinue or change any product line, specification or electronic media without prior written notice. NOTE: Dimensions in parentheses ( ) are millimeters unless otherwise noted. Other metric units shown in this publication are: m - meter Kg - kilogram Pa - pascal KPa - kilopascal MPa - megapascal Online usalum.com y Phone (00) - Online crlaurence.com y Phone (00) -

2 0- Specifications SECTION 0 FRMED Series FF0 Series FF Series FF00 Series FF0 SERIES FCE WIDTH DEPTH GLZING INFILL GLZING METHOD FF0 -/ (.) /" () or /" (0) FF -/ (.) " () FF00 " (.) /" () or /" (0) Exterior/Interior FF0 " (.) " () I. GENERL DESCRIPTION Work Included: Furnish all necessary materials, labor, and equipment for the complete installation of aluminum framing as shown on the drawings and specified herein. (Specifier Note: It is suggested that related items such as aluminum entrance doors, glass, and sealants be included whenever possible). Work Not Included: Structural support of the framing system, interior closures, trim. (Specifier list other exclusions). Related Work Specified Elsewhere: (Specifier list). QULITY SSURNCE Drawings and specifications are based on the Series (Specify) Flush Front System as manufactured by U.S. luminum. Whenever substitute products are to be considered, supporting technical literature, samples, drawings, and performance data must be submitted 0 days prior to bid in order to make a valid comparison of the products involved. Test reports certified by an independent test laboratory must be made available upon request. PERFORMNCE REQUIREMENTS ir Infiltration: shall be tested in accordance with STM E. Infiltration shall not exceed.0 cfm per square foot (.000m /sm ) of fixed area when tested at. psf (00 Pa). Water Infiltration: shall be tested in accordance with STM E. No water penetration at test pressure of psf ( Pa) when tested with the high performance subsill. Structural Performance: shall be tested in accordance with STM E 0 and based on: Maximum deflection of L/ of the span llowable stress with a safety factor of. The system shall perform to this criteria under a windload of (Specify) psf. Testing Procedures - STM, E, and E 0 - Laboratory performance testing. M Newly installed storefronts. M -0 - Installed storefronts after six months. II. PRODUCTS MTERILS Extrusions shall be 0-T alloy and temper (STM alloy T temper). Fasteners, where exposed, shall be aluminum, stainless steel or zinc plated steel in accordance with STM. Perimeter anchors shall be aluminum or steel, providing the steel is properly isolated from the aluminum. Glazing gaskets shall be E.P.D.M. elastomeric extrusions. FINISH ll exposed framing surfaces shall be free of scratches and other serious blemishes. luminum extrusions shall be given a caustic etch followed by an anodic oxide treatment to obtain (Specify one of the following): # Clear anodic coating # Dark ronze anodic coating # lack anodic coating Fluoropolymer paint coating conforming with the requirements of M 0. Color shall be (Specify a U.S. luminum standard color). FRICTION The framing system shall provide for flush glazing on all sides with no projecting stops. Vertical and horizontal framing members shall have a nominal face dimension of (Specify). Overall depth shall be (Specify). Entrance framing members shall be compatible with glass framing in appearance. Provide for internal drainage of infiltrated water into an extruded aluminum subsill channel where it is drained to the exterior through weep slots. III. EXECUTION INSTLLTION ll glass framing shall be set in correct locations as shown in the details and shall be level, square, plumb, and in alignment with other work in accordance with the manufacturer s installation instructions and approved shop drawings. ll joints between framing and the building structure shall be sealed in order to secure a watertight installation. PROTECTION ND CLENING fter installation the General Contractor shall adequately protect exposed portions of aluminum surfaces from damage by grinding and polishing compounds, plaster, lime, acid, cement or other contaminants. The General Contractor shall be responsible for final cleaning. Online usalum.com y Phone (00) - Online crlaurence.com y Phone (00) -

3 0- Specifications SECTION 0 FRMED Thermal Series FT Series FT0 SERIES FCE WIDTH DEPTH GLZING INFILL GLZING METHOD FT -/ (.) FT0 " (.) " () Exterior/Interior I. GENERL DESCRIPTION Work Included: Furnish all necessary materials, labor, and equipment for the complete installation of aluminum framing as shown on the drawings and specified herein. (Specifier Note: It is suggested that related items such as aluminum entrance doors, glass, and sealants be included whenever possible). Work Not Included: Structural support of the framing system, interior closures, trim. (Specifier list other exclusions). Related Work Specified Elsewhere: (Specifier list). QULITY SSURNCE Drawings and specifications are based on the Series (Specify) Thermal Flush Front System as manufactured by U.S. luminum. Whenever substitute products are to be considered, supporting technical literature, samples, drawings, and performance data must be submitted 0 days prior to bid in order to make a valid comparison of the products involved. Test reports certified by an independent test laboratory must be made available upon request. PERFORMNCE REQUIREMENTS ir Infiltration: shall be tested in accordance with STM E. Infiltration shall not exceed.0 cfm per square foot (.000m /sm ) of fixed area when tested at. psf (00 Pa). Water Infiltration: shall be tested in accordance with STM E. No water penetration at test pressure of psf ( Pa). When tested with the high performance subsill. Structural Performance: shall be tested in accordance with STM E 0 and based on: Maximum deflection of L/ of the span llowable stress with a safety factor of. The system shall perform to this criteria under a windload of (Specify) psf. Structural Integrity - Manufacturer shall provide a Two Year Warranty on thermal framing against failure. Thermal Performance - Series FT/FT0 shall be tested in accordance with NFRC 00, 00, and M 0. The system shall perform to this criteria under a windload of (Specify) psf. Testing Procedures - STM, E, and E 0 - Laboratory performance testing. M Newly installed storefronts. M -0 - Installed storefronts after six months. II. PRODUCTS MTERILS Extrusions shall be 0-T alloy and temper (STM alloy T temper), thermally broken by a two part chemically cured high density polyurethane. To ensure that composite strength remains unaltered during thermal cycling, a mechanical bond between the aluminum and the thermal filling shall be created by mechanically abrading the extrusion thermal cavity prior to filling with the polyurethane polymer. Fasteners, where exposed, shall be aluminum, stainless steel or zinc plated steel in accordance with STM. Perimeter anchors shall be aluminum or steel, providing the steel is properly isolated from the aluminum. Glazing gaskets shall be E.P.D.M. elastomeric extrusions. FINISH ll exposed framing surfaces shall be free of scratches and other serious blemishes. luminum extrusions shall be given a caustic etch followed by an Online usalum.com y Phone (00) - Online crlaurence.com y Phone (00) - anodic oxide treatment to obtain (Specify one of the following): # Clear anodic coating # Dark ronze anodic coating # lack anodic coating Fluoropolymer paint coating conforming with the requirements of M 0. Color shall be (Specify a U.S. luminum standard color). FRICTION The framing system shall provide for flush glazing on all sides with no projecting stops. Vertical and horizontal framing members shall have a nominal face dimension of. Overall depth shall be (Specify). Entrance framing members shall be compatible with glass framing in appearance. Provide for internal drainage of infiltrated water into an extruded aluminum subsill channel where it is drained to the exterior through weep slots. III. EXECUTION INSTLLTION ll glass framing shall be set in correct locations as shown in the details and shall be level, square, plumb, and in alignment with other work in accordance with the manufacturer s installation instructions and approved shop drawings. ll joints between framing and the building structure shall be sealed in order to secure a watertight installation. PROTECTION ND CLENING fter installation the General Contractor shall adequately protect exposed portions of aluminum surfaces from damage by grinding and polishing compounds, plaster, lime, acid, cement, or other contaminants. The General Contractor shall be responsible for final cleaning.

4 0- Technical Data Systems feature screw race joinery and panel type installation, which allows for shop or job site fabrication. Injection molded water deflectors at intermediate horizontals, and a continuous sill gutter with factory pre-punched weep slots, ensure control of any infiltrated water. The plane of the glass may be reversed from exterior to interior or any combination to give these standard systems a custom look. Series FT and FT0 offer improved thermal performance using the Poly-luminizer thermal break technology as described on page -. ll series may be glazed from the interior or exterior using a top load E.P.D.M. glazing gasket, see page 0-. This multi-purpose product was also designed and tested for use as a Window Wall System, and is an ideal choice for fixed horizontal ribbon window applications. Flush Front Systems accommodate most U.S. luminum Entrance Doors. Series FF0 Series FF Series FT Series FF00 Series FF0 Series FT0 FLUSH FRONT SERIES WIDTH DEPTH GLZING INFILLS PPLICTION FF0 -/ (.) /" () or /" (0) FF -/ (.) " () FT (Thermal) -/ (.) " () FF00 " (.) /" () or /" (0) FF0 " (.) " () Ground Floor to Mid-Rise uildings. Ideal for Fixed Horizontal Ribbon Windows. FT0 (Thermal) " (.) " () GLSS SIZES* Series FF0 and FF00 for /" () Glass Series FF, FT, FF0, and FT0 for " () Glass = Daylight Opening + /" (.) = Daylight Opening + /" (.) * These formulae do not take into account glass tolerances. Consult glass manufacturer before ordering glass. Online usalum.com y Phone (00) - Online crlaurence.com y Phone (00) -

5 0- Special Features Systems allow the plane of the glass to be reversed from exterior to interior or any combination to give these standard systems a custom look. is ideal for use in storefront and punched opening or ribbon window applications. Systems accommodate most U.S. luminum Entrance Doors. Series FF0 Series FF Series FT Series FF00 Series FF0 Series FT0 System features screw race joinery with split vertical mullions which allows for framing to be shop fabricated and shipped to the job site partially or totally assembled into panels. The assembled panel units are then snapped together into long runs. Subsills with factory pre-punched weep slots must be used with these systems. pply silicone to two sides of glazing pocket at vertical/horizontal joint and glazing reglets. Slide water deflector, down into position. Seal over top edges of water deflector, leaving a gap on outside edge allowing water to drain into subsill. Water Deflector Stretch "W" lock and slide it between glass and mullion into deep glazing pocket. Push it all the way until it clears glass and locks into place. These blocks are used to prevent glass from "walking" out of the pocket caused by extreme vibration or minor earthquakes. "W" Edge lock Online usalum.com y Phone (00) - Online crlaurence.com y Phone (00) -

6 0- FLUSH OUT FOR /" () OR /" (0) GLZING NOTE: Part numbers shown are available in ' (. m) stock lengths. Visit usalum.com for more information. Series FF0 NOTE: NP E.P.D.M. Glazing Gaskets used on both sides of /" () glass throughout. NP E.P.D.M. Glazing Gaskets for /" (0) glazing. TYPICL ELEVTION EC0 Subsill's End Closure (Typ.) SS Optional Steel Stiffener SS Optional Steel Stiffener FF FF FF PF00 RF00 FF0 -/ (.) /" (.) Min. / (.) FRME WIDTH HC00 Optional Head nchor FF FF FRME HEIGHT FF M- M- FH M- FF M- FH FF00 M- FF00 NOT TO SCLE /" (.) Min. Online usalum.com y Phone (00) - Online crlaurence.com y Phone (00) - Interior Glazing Weep Slot Exterior Glazing

7 0- FLUSH IN FOR /" () OR /" (0) GLZING Series FF0 NOTE: Part numbers shown are available in ' (. m) stock lengths. Visit usalum.com for more information. NOTE: NP E.P.D.M. Glazing Gaskets used on both sides of /" () glass throughout. NP E.P.D.M. Glazing Gaskets for /" (0) glazing. TYPICL ELEVTION EC0 Subsill's End Closure PF00 FF RF00 FF FF0 FF -/ (.) /" (.) Min. FRME WIDTH SS Optional Steel Stiffener SS Optional Steel Stiffener / (.) HC00 Optional Head nchor FF FRME HEIGHT M- M- FF FH FF00 /" (.) Min. Exterior Glazing Online usalum.com y Phone (00) - Online crlaurence.com y Phone (00) - NOT TO SCLE

8 0- FLUSH IN / FLUSH OUT FOR /" () OR /" (0) GLZING Series FF0 NOTE: Part numbers shown are available in ' (. m) stock lengths. Visit usalum.com for more information. 0 NOTE: NP E.P.D.M. Glazing Gaskets used on both sides of /" () glass throughout. NP E.P.D.M. Glazing Gaskets for /" (0) glazing. EC0 Subsill's End Closure TYPICL ELEVTION PF00 FF FF FF -/ FF (.) RF00 RF00 FF0 /" (.) Min. FRME WIDTH / (.) HC00 Optional Head nchor FF FF FRME HEIGHT M- FH M- M- FH FF FF 0 FF00 FF00 NOT TO SCLE /" (.) Min. Online usalum.com y Phone (00) - Online crlaurence.com y Phone (00) - Exterior Glazing

9 0- DOOR FRMING Series FF0 NOTE: Doors are available in stock to accommodate " x " ( x ) and x " ( x ) door openings. Visit usalum.com for more information. NOTE: NP E.P.D.M. Glazing Gaskets used on both sides of /" () glass throughout. NP E.P.D.M. Glazing Gaskets for /" (0) glazing. CENTER HUNG DOOR PF00 Filler (Typ.) / (.) FF FF RF00 JS M- /" (.) M-/ M- 00M Center Hung Closer 0 N.H.O. M-/ M- -/ (.) FF/ P-00 D-00 M-0 FF/ P-00 RF00 FRME HEIGHT JC/ P- Center D-0 Pivot Top Portion D-0 M-0 M-0 J-0 /" (.) D.O. /" (.) D.O. FRME WIDTH M-0 M-0 /" (.) D-0 D-0 NOT TO SCLE / (.) TH0 Threshold Online usalum.com y Phone (00) - Online crlaurence.com y Phone (00) - TH0 Threshold (Use With Floor Closers)

10 0- DOOR FRMING Series FF0 NOTE: Doors are available in stock to accommodate " x " ( x ) and x " ( x ) door openings. Visit usalum.com for more information. NOTE: NP E.P.D.M. Glazing Gaskets used on both sides of /" () glass throughout. NP E.P.D.M. Glazing Gaskets for /" (0) glazing. OFFSET HUNG DOORS PF00 Filler (Typ.) / (.) FF P-00 I-/ I- FF P-00 RF00 M- FF M- FF /" (.) I-/ I- I-/ I- 0U Closer With Offset rm 0 N.H.O. -/ (.) FF/ DS0 FF/ DS0 RF00 FRME HEIGHT /" (.) D-0 M-0 DS0/ MC0 D-0 J-0 D0 DT0 M-0 M-0 / (.) D.O. FRME WIDTH / (.) D.O. Door Sweep With Concealed Fasteners Door Sweep With Concealed Fasteners D-0 /" (.) W00 D-0 /" (.) W00 NOT TO SCLE / (.) TH0 Online usalum.com y Phone (00) - Online crlaurence.com y Phone (00) - TH0 / (.)

11 - DOOR FRMING SPECIL CONDITION Series FF0 FF FF DS0 DS0 RF00 RF00 M-0 TYPICL ELEVTION ( Wide Door Jambs with RF00 Fillers are required to install glass between doors) D.O. DT0 D.O. VERTICL CORNER CONDITIONS FOR /" () GLZING 0 DEGREES FF FF0 FF0 FF0 DIMENSION POINTS -/ (.) DIMENSION POINTS -/ (.) DEGREES OG OG RF00 RF00 /" (.) RF00 RF00 -/" (.) DIMENSION POINTS DIMENSION POINTS NOT TO SCLE Online usalum.com y Phone (00) - Online crlaurence.com y Phone (00) -

12 - Windload Charts VERTICL MULLIONS FOR /" () OR /" (0) GLZING Mullions designed for L/ deflection ratio and for the following allowable working stresses: luminum alloy 0-T: allowable stress for windload, psi. ( MPa) Steel reinforcing: allowable stress for windload, psi. ( MPa) Series FF0 Curves represent the limit values and are based on criteria for simple beam, uniformly loaded, using the distribution of wind forces on the wall with rectangular loading. Glass is not considered as contributing to resistance of deflection. Limitation of vertical mullions for: CURVES = PSF ( Pa) CURVES = 0 PSF ( Pa) CURVES C = PSF ( Pa) CURVES D = 0 PSF ( Pa) FF/RF00 I =. (0. x 0 ) S =. (.0 x 0 ) SS Steel Stiffener I =. (. x 0 ) S =. (. x 0 ) IL+STL =. (0. x 0 ) FF0/FF I =. (. x 0 ) S =. (. x 0 ) SS Steel Stiffener I =. (. x 0 ) S =. (. x 0 ) IL+STL =. (0.0 x 0 ) FF/RF00 I =. (. x 0 ) S =. (. x 0 ) /" x " Steel ar I =. (. x 0 ) S =. (. x 0 ) IL+STL =. (. x 0 ) () (.) () (.) () (.) () (.) Mullion Height in Feet (meters) 0 C D () (.) () (.) () FF/ RF00 0 D C (.) () (.) () (.) FF/ RF00 With SS Mullion Spacing in Feet (meters) Online usalum.com y Phone (00) - Online crlaurence.com y Phone (00) -

13 - Windload Charts VERTICL MULLIONS FOR /" () OR /" (0) GLZING Series FF0 Limitation of vertical mullions for: CURVES = PSF ( Pa) CURVES = 0 PSF ( Pa) CURVES C = PSF ( Pa) CURVES D = 0 PSF ( Pa) () (.) () (.) () (.) () (.) (.) () Mullion Height in Feet (meters) 0 C D () (.) () (.) () FF0/ FF C 0 D (.) () (.) () (.) FF/ FF With SS Mullion Spacing in Feet (meters) () (.) () (.) () (.) () (.) (.) () Mullion Height in Feet (meters) () (.) 0 C () (.) D () FF/ RF00 C 0 D (.) () (.) () (.) FF/ RF00 With /" x " Steel Mullion Spacing in Feet (meters) Online usalum.com y Phone (00) - Online crlaurence.com y Phone (00) -

14 - Deadload Charts Series FF0 INTERMEDITE HORIZONTL MULLIONS FOR /" () OR /" (0) GLZING Deadload charts are based on /" (.) maximum allowable deflection at the center point of the horizontal mullion and on a glass weight of. psf (. Kg/m ) Glass shall rest on two setting blocks located at: CURVES : / points CURVES : / points or " (0.) from corners, whichever is larger Height of Glass in Feet (meters) () (.) () (.) 0 (.) () (.) () (.) FH Iyy =.0 (. x 0 ) (.) () (.) () (.) 0 0 (.) () (.) () (.) () FH Iyy =. (. x 0 ) Mullion Span in Feet (meters) DOOR HEDERS Deadload charts for door headers are based on /" (.) maximum allowable deflection at the center point of the header and on a glass weight of. psf (. Kg/m ) Glass shall rest on two setting blocks located at: CURVES : / points CURVES : / points or " (0.) from corners, whichever is larger () (.) () (.) () (.) () (.) Height of Glass in Feet (meters) 0 () (.) () (.) () JS Iyy =. (.0 x 0 ) (.) () (.) () (.) J-0 Iyy =.0 (. x 0 ) 0 0 Mullion Span in Feet (meters) Online usalum.com y Phone (00) - Online crlaurence.com y Phone (00) -

15 - FLUSH OUT FOR " () GLZING NOTE: Part numbers shown are available in ' (. m) stock lengths. Visit usalum.com for more information. Series FF Series FT F T 0 0 Part Number prefix ending in "T" represents THERMLLY ROKEN parts. Thermal parts are in OLD print. Series FT details are typically shown. TYPICL ELEVTION NOTE: NP E.P.D.M. Glazing Gaskets used on both sides of glazing throughout. EC0 Subsill's End Closure (Typ.) SS Optional Steel Stiffener SS Optional Steel Stiffener PT00 PF00 FT FF RX0 RF0 FT FF FT0 FF0 FT FF -/ (.) /" (.) Min. FRME WIDTH / (.) HC00 Optional Head nchor FT FF FT FF FRME HEIGHT M- M- FT FF FT FH FT00 FF00 M- M- M- FT FF FT FH FT00 FF00 /" (.) Min. Interior Glazing Weep Slot Exterior Glazing Online usalum.com y Phone (00) - Online crlaurence.com y Phone (00) - NOT TO SCLE

16 - FLUSH IN FOR " () GLZING NOTE: Part numbers shown are available in ' (. m) stock lengths. Visit usalum.com for more information. Series FF Series FT F T 0 0 Part Number prefix ending in "T" represents THERMLLY ROKEN parts. Thermal parts are in OLD print. Series FT details are typically shown. TYPICL ELEVTION NOTE: NP E.P.D.M. Glazing Gaskets used on both sides of glazing throughout. EC0 Subsill's End Closure (Typ.) PT00 PF00 FT FF FT FF FT FF -/ (.) RX0 RF0 FT0 FF0 SS Optional Steel Stiffener SS Optional Steel Stiffener /" (.) Min. FRME WIDTH / HC00 (.) Optional Head nchor FT FF M- FRME HEIGHT M- FT FH FT FF FT00 FF00 NOT TO SCLE Online usalum.com y Phone (00) - Online crlaurence.com y Phone (00) - /" (.) Min. Exterior Glazing

17 - FLUSH IN / FLUSH OUT FOR " () GLZING NOTE: Part numbers shown are available in ' (. m) stock lengths. Visit usalum.com for more information. EC0 Subsill's End Closure (Typ.) 0 TYPICL ELEVTION Series FF Series FT F T 0 0 Part Number prefix ending in "T" represents THERMLLY ROKEN parts. Thermal parts are in OLD print. Series FT details are typically shown. NOTE: NP E.P.D.M. Glazing Gaskets used on both sides of glazing throughout. PT00 PF00 FT FF RX0 RF0 FT FF RX0 RF0 FT FF -/ (.) FT0 FF0 FT FF /" (.) Min. / (.) FRME WIDTH HC00 Optional Head nchor FT FF FT FF FRME HEIGHT M- M- M- FT FH FT FF FT00 FF00 M- M- FT FH 0 FT FF FT00 FF00 /" (.) Min. Exterior Glazing Online usalum.com y Phone (00) - Online crlaurence.com y Phone (00) - NOT TO SCLE

18 - DOOR FRMING Series FF Series FT NOTE: Doors are available in stock to accommodate " x " ( x ) and x " ( x ) door openings. Visit usalum.com for more information. NOTE: NP E.P.D.M. Glazing Gaskets used on both sides of glazing throughout. CENTER HUNG DOOR PF00 Filler / (.) FF FF RF0* RX0 or RF0 IS /" (.) I-/ IM I-/ IM /" (.) " (.) " (.) () M- 00M Center Hung Closer 0 N.H.O. I-/ IM FF/ P-00 D-00 /" (.) D.O. M-0 FF/ P-00 FRME WIDTH Typ. /" (.) RF0* RX0 or RF0 FRME HEIGHT D.O. /" (.) IC/ P- D-0 M-0 M-0 Center Pivot Top Portion D-0 M-0 M-0 I-0 /" (.) D-0 D-0 NOT TO SCLE Online usalum.com y Phone (00) - Online crlaurence.com y Phone (00) - / (.) TH0 Threshold TH0 Threshold (Use With Floor Closers) *NOTE: RF0 FILLER REQUIRED TO INSTLL GLSS ETWEEN DOORS

19 - DOOR FRMING Series FF Series FT NOTE: Doors are available in stock to accommodate " x " ( x ) and x " ( x ) door openings. Visit usalum.com for more information. NOTE: NP E.P.D.M. Glazing Gaskets used on both sides of glazing throughout. OFFSET HUNG DOOR PF00 Filler / (.) FF/ P-00 FF/ P-00 RF0* RX0 or RF0 FT FF /" (.) I-/ IM I-/ IM /" (.) " (.) I-0 0U Closer With Offset rm 0º N.H.O. I-/ IM " (.) I-0 FF/ DS0 DT0 / (.) D.O. FF/ DS0 M0 (Typ.) FRME WIDTH / (.) RF0* RX0 or RF0 FRME HEIGHT D.O. /" (.) D-0/ M-0 M-0/ D-0 DS0/ MC0 Door Sweep With Concealed Fasteners D-0 M-0 M-0 D-0 D0 Door Sweep With Concealed Fasteners /" (.) W00 W00 TH0 TH0 NOT TO SCLE / (.) TH0 Threshold (Use With Floor Closers) *NOTE: RF0 FILLER REQUIRED TO INSTLL GLSS ETWEEN DOORS Online usalum.com y Phone (00) - Online crlaurence.com y Phone (00) -

20 0- VERTICL CORNER CONDITIONS FOR " () GLZING Series FF Series FT F T 0 0 NOTE: NP E.P.D.M. Glazing Gaskets used on both sides of glazing throughout. Part Number prefix ending in "T" represents THERMLLY ROKEN parts. Thermal parts are in OLD print. Series FT details are typically shown. FT0 FF0 0 DEGREES FT0 FF0 FT0 FF0 DIMENSION POINTS FT FF -/ (.) DIMENSION POINTS -/ (.) DEGREES OG RF0 OG RF0 RF0 RF0 /" (.) DIMENSION POINTS -/" (.) DIMENSION POINTS NOT TO SCLE Online usalum.com y Phone (00) - Online crlaurence.com y Phone (00) -

21 - TRNSITION GLZING Series FF Series FT NOTE: Part numbers shown are available in ' (. m) stock lengths. Visit usalum.com for more information. F T 0 0 Part Number prefix ending in "T" represents THERMLLY ROKEN parts. Thermal parts are in OLD print. Series FT details are typically shown. 0 0 NOTE: NP E.P.D.M. Glazing Gaskets used on both sides of /" () glass throughout. NP E.P.D.M. Glazing Gaskets for /" (0) glazing. FLUSH OUT FLUSH IN FLUSH IN / FLUSH OUT RX0 RF0 FT RX0 FF RF0 FT FF FT FF FT FF IS IS M- M- IS IS FT M- FH IS FT FH IS IS M- RX0 RF0 FT RX0 FF RF0 FT FF M- FT FH FT FH IS M- IS RX0 RF0 FT FF IS RX0 RF0 FT FF IS M- 0 IS FT FF FT00 FF00 FT FF IS FT00 FF00 Exterior Glazing NOT TO SCLE Online usalum.com y Phone (00) - Online crlaurence.com y Phone (00) -

22 - Windload Charts VERTICL MULLIONS FOR " () GLZING Mullions designed for L/ deflection ratio and for the following allowable working stresses: Series FF Series FT luminum alloy 0-T: allowable stress for windload, psi. ( MPa) Steel reinforcing: allowable stress for windload, psi. ( MPa) Curves represent the limit values and are based on criteria for simple beam, uniformly loaded, using the distribution of wind forces on the wall with rectangular loading. Glass is not considered as contributing to resistance of deflection. Limitation of vertical mullions for: CURVES = PSF ( Pa) CURVES = 0 PSF ( Pa) CURVES C = PSF ( Pa) CURVES D = 0 PSF ( Pa) FT/RX0 or FF/RF0 I =.0 ( x 0 ) S =. (0. x 0 ) SS Steel Stiffener I =. (. x 0 ) S =. (. x 0 ) IL+STL =. (. x 0 ) FT0/FT or FF0/FF I =. (. x 0 ) S =. (. x 0 ) SS Steel Stiffener I =. (. x 0 ) S =. (. x 0 ) IL+STL =. (. x 0 ) FF/RX0 or FF/RF0 I =. (. x 0 ) S =. (.0 x 0 ) SS0 Steel Stiffener I =. (.0 x 0 ) S =. (. x 0 ) IL+STL =. (. x 0 ) () (.) () (.) (.) () (.) () (.) () Mullion Height in Feet (meters) 0 C D () (.) () (.) () FT/RX0 FF/RF0 0 C D (.) () (.) () (.) FT/RX0 FF/RF0 With SS Mullion Spacing in Feet (meters) Online usalum.com y Phone (00) - Online crlaurence.com y Phone (00) -

23 - Windload Charts VERTICL MULLIONS FOR " () GLZING Series FF Series FT Limitation of vertical mullions for: CURVES = PSF ( Pa) CURVES = 0 PSF ( Pa) CURVES C = PSF ( Pa) CURVES D = 0 PSF ( Pa) () (.) () (.) (.) () (.) () (.) () Mullion Height in Feet (meters) 0 C D () (.) () (.) FT0/FT FF0/FF 0 D C (.) () (.) () FT0/FT FF0/FF With SS (.) Mullion Spacing in Feet (meters) () (.) () (.) (.) () (.) () (.) () Mullion Height in Feet (meters) 0 D C () (.) () (.) FF/RX0 FF/RF0 0 D C (.) () (.) () FF/RX0 FF/RF0 With SS0 () (.) Mullion Spacing in Feet (meters) Online usalum.com y Phone (00) - Online crlaurence.com y Phone (00) -

24 - Deadload Charts INTERMEDITE HORIZONTL MULLIONS FOR " () GLZING Series FF Series FT Deadload charts are based on /" (.) maximum allowable deflection at the center point of the horizontal mullions and on a glass weight of. psf (. Kg/m ) Glass shall rest on two setting blocks located at: CURVES : / points CURVES : / points or " (0.) from corners, whichever is larger Height of Glass in Feet (meters) Height of Glass in Feet (meters) DOOR HEDERS () (.) () (.) (.) () (.) () (.) 0 FT FH Iyy =.0 (. x 0 ) Mullion Span in Feet (meters) Deadload charts for door headers are based on /" (.) maximum allowable deflection at the center point of the header and on a glass weight of. psf (. Kg/m ) Glass shall rest on two setting blocks located at: CURVES : / points CURVES : / points or " (0.) from corners, whichever is larger () (.) () (.) (.) () (.) () (.) IS Iyy =. (. x 0 ) () (.) () (.) 0 () (.) () (.) (.) () (.) () (.) (.) () (.) () (.) FT FH Iyy =. (. x 0 ) I-0 Iyy =. (. x 0 ) 0 0 Mullion Span in Feet (meters) Online usalum.com y Phone (00) - Online crlaurence.com y Phone (00) -

25 - FLUSH OUT FOR /" () OR /" (0) GLZING NOTE: Part numbers shown are available in ' (. m) stock lengths. Visit usalum.com for more information. Series FF00 NOTE: NP E.P.D.M. Glazing Gaskets used on both sides of /" () glass throughout. NP E.P.D.M. Glazing Gaskets for /" (0) glazing. TYPICL ELEVTION EC0 Subsill's End Closure (Typ.) SS Optional Steel Stiffener SS Optional Steel Stiffener FF FF FF FF00 RF00 FF0 " (.) /" min. (.) FRME WIDTH / (.) HC00 Optional Head nchor FF FF FRME HEIGHT M- M- FF FH FF00 M- M- M- FF FH FF00 /" min. (.) Interior Glazing Weep Slot Exterior Glazing Online usalum.com y Phone (00) - Online crlaurence.com y Phone (00) - NOT TO SCLE

26 - FLUSH IN FOR /" () OR /" (0) GLZING NOTE: Part numbers shown are available in ' (. m) stock lengths. Visit usalum.com for more information. Series FF00 NOTE: NP E.P.D.M. Glazing Gaskets used on both sides of /" () glass throughout. NP E.P.D.M. Glazing Gaskets for /" (0) glazing. EC0 Subsill s End Closure (Typ.) TYPICL ELEVTION FF FF FF FF00 RF00 FF0 " (.) /" min. (.) SS Optional SS Optional Steel Stiffener Steel Stiffener FRME WIDTH / (.) HC00 Optional Head nchor FF FRME HEIGHT M- M- FF FH FF00 NOT TO SCLE /" min. (.) Exterior Glazing Online usalum.com y Phone (00) - Online crlaurence.com y Phone (00) -

27 - FLUSH IN / FLUSH OUT FOR /" () OR /" (0) GLZING NOTE: Part numbers shown are available in ' (. m) stock lengths. Visit usalum.com for more information. 0 Series FF00 NOTE: NP E.P.D.M. Glazing Gaskets used on both sides of /" () glass throughout. NP E.P.D.M. Glazing Gaskets for /" (0) glazing. TYPICL ELEVTION EC0 Subsill s End Closure (Typ.) FF FF FF FF " (.) FF00 RF00 RF00 FF0 /" min. (.) / (.) FRME WIDTH HC00 Optional Head nchor FF FF FRME HEIGHT M- M- M- FH M- FF 0 FF FH M- FF00 FF00 /" min. (.) Exterior Glazing Online usalum.com y Phone (00) - Online crlaurence.com y Phone (00) - NOT TO SCLE

28 - DOOR FRMING Series FF00 NOTE: Doors are available in stock to accommodate " x " ( x ) and x " ( x ) door openings. Visit usalum.com for more information. or NOTE: NP E.P.D.M. Glazing Gaskets used on both sides of /" () glass throughout. NP E.P.D.M. Glazing Gaskets for /" (0) glazing. CENTER HUNG DOOR OFFSET HUNG DOOR SPECIL JM CONDITION ( Wide Door Jambs with RF00 fillers are required to install glass between doors.) FF FF RF00 FF RF00 FF00 Filler (Typ.) P-00 P-00 P-00 " (.) I-/ I- I-/ I- I-/ I- -/" -/" (.) (.) " (.) FF FF FF RF00 RF00 P-00 P-00 P-00 M-0 M-0 D-00 D-00 M-0 D-00 /" (.) /" (.) /" (.) D.O. D.O. /" min. (.) FF FF FF DS0 DS0 RF00 DS0 RF00 NOT TO SCLE DT0 / (.) M-0 M-0 D.O. M-0 DT0 DT0 / (.) / (.) D.O. Online usalum.com y Phone (00) - Online crlaurence.com y Phone (00) -

29 - DOOR FRMING NOTE: Doors are available in stock to accommodate " x " ( x ) and x " ( x ) door openings. Visit usalum.com for more information. Series FF00 / (.) " (.) HC00 Optional Head nchor M- FF CENTER HUNG DOOR NOTE: NP E.P.D.M. Glazing Gaskets used on both sides of /" () glass throughout. NP E.P.D.M. Glazing Gaskets for /" (0) glazing. OFFSET HUNG DOOR 0U Closer With Offset rm 0º N.H.O. " (.) I-/ I- I-/ I- I-/ I- " (.) /" (.) D-0 M-0 J-00 J-00 J-00 /" DS0/ /" (.) MC0 (.) D0 D-0/ M-0 D-0/ M-0 D.O. D.O. M-0 M-0 M-0 /" (.) D-0 D-0 /" (.) Door Sweep With Concealed Fasteners W00 D-0 /" (.) Door Sweep With Concealed Fasteners W00 / (.) TH0 / (.) / (.) Online usalum.com y Phone (00) - Online crlaurence.com y Phone (00) - TH0 TH0 NOT TO SCLE

30 0- Windload Charts VERTICL MULLIONS FOR /" () OR /" (0) GLZING Series FF00 Mullions designed for L/ deflection ratio and for the following allowable working stresses: luminum alloy 0-T: allowable stress for windload, psi. ( MPa) Steel reinforcing: allowable stress for windload, psi. ( MPa) Curves represent the limit values and are based on criteria for simple beam, uniformly loaded, using the distribution of wind forces on the wall with rectangular loading. Glass is not considered as contributing to resistance of deflection. Limitation of vertical mullions for: CURVES = PSF ( Pa) CURVES = 0 PSF ( Pa) CURVES C = PSF ( Pa) CURVES D = 0 PSF ( Pa) FF/RF00 I =. (. x 0 ) S =. (0.0 x 0 ) SS Steel Stiffener I =. (. x 0 ) S =.0 ( x 0 ) IL+STL =.0 (. x 0 ) FF0/FF I =. (. x 0 ) S =. (. x 0 ) SS Steel Stiffener I =. (. x 0 ) S =. (. x 0 ) IL+STL =. (. x 0 ) FF/RF00 I =.0 (. x 0 ) S =. (. x 0 ) /" x -/ Steel ar I =. ( x 0 ) S =. (. x 0 ) IL+STL =. (.0 x 0 ) () (.) () (.) (.) 0 () (.) () (.) () Mullion Height in Feet (meters) 0 C D () (.) () (.) FF/ RF00 D C (.) () (.) () (.) FF/ RF00 With SS Mullion Spacing in Feet (meters) Online usalum.com y Phone (00) - Online crlaurence.com y Phone (00) -

31 - Windload Charts VERTICL MULLIONS FOR /" () OR /" (0) GLZING Series FF00 Limitation of vertical mullions for: CURVES = PSF ( Pa) CURVES = 0 PSF ( Pa) CURVES C = PSF ( Pa) CURVES D = 0 PSF ( Pa) () (.) () (.) () (.) () (.) () 0 () Mullion Height in Feet (meters) 0 C D (.) () (.) () FF0/ FF D C (.) () (.) () FF0/ FF With SS (.) (.) Mullion Spacing in Feet (meters) () (.) () (.) () (.) () (.) () 0 () Mullion Height in Feet (meters) 0 C D (.) () (.) () (.) FF/ RF00 C D (.) () (.) () (.) FF/ RF00 With /" x -/ Steel Mullion Spacing in Feet (meters) Online usalum.com y Phone (00) - Online crlaurence.com y Phone (00) -

32 - Deadload Charts INTERMEDITE HORIZONTL MULLIONS FOR /" () OR /" (0) GLZING Deadload charts are based on /" (.) maximum allowable deflection at the center point of the horizontal mullion and on a glass weight of. psf (. Kg/m ) Glass shall rest on two setting blocks located at: CURVES : / points CURVES : / points or " (0.) from corners, whichever is larger Series FF00 0 () (.) () (.) () 0 (.) () (.) () () Height of Glass in Feet (meters) (.) () (.) () FH Iyy =. (. x 0 ) (.) () (.) () FH Iyy =. (. x 0 ) (0.) 0 (0.) Mullion Span in Feet (meters) DOOR HEDERS Deadload charts for door headers are based on /" (.) maximum allowable deflection at the center point of the header and on a glass weight of. psf (. Kg/m ) Glass shall rest on two setting blocks located at: CURVES : / points CURVES : / points or " (0.) from corners, whichever is larger 0 () (.) () (.) () Height of Glass in Feet (meters) (.) () (.) () J-00 Iyy =. (.0 x 0 ) (0.) 0 Mullion Spacing in Feet (meters) Online usalum.com y Phone (00) - Online crlaurence.com y Phone (00) -

33 - FLUSH OUT FOR " () GLZING NOTE: Part numbers shown are available in ' (. m) stock lengths. Visit usalum.com for more information. Series FF0 Series FT0 F T 0 0 Part Number prefix ending in "T" represents THERMLLY ROKEN parts. Thermal parts are in OLD print. Series FT0 details are typically shown. TYPICL ELEVTION NOTE: NP E.P.D.M. Glazing Gaskets used on both sides of glazing throughout. EC0 Subsill's End Closure (Typ.) SS Optional Steel Stiffener SS Optional Steel Stiffener FT00 FF00 FT FF RX0 RF0 FT FF FT0 FF0 FT FF " (.) /" (.) Min. FRME WIDTH / (.) HC00 Optional Head nchor FT FF FT FF FRME HEIGHT M- M- M- FT FH FT FF FT00 FF00 M- M- FT FH FT FF FT00 FF00 /" (.) Min. Interior Glazing Weep slot (Typ.) Online usalum.com y Phone (00) - Online crlaurence.com y Phone (00) - Exterior Glazing NOT TO SCLE

34 - FLUSH IN FOR " () GLZING NOTE: Part numbers shown are available in ' (. m) stock lengths. Visit usalum.com for more information. Series FF0 Series FT0 F T 0 0 Part Number prefix ending in "T" represents THERMLLY ROKEN parts. Thermal parts are in OLD print. Series FT0 details are typically shown. EC0 Subsill's End Closure (Typ.) TYPICL ELEVTION NOTE: NP E.P.D.M. Glazing Gaskets used on both sides of glazing throughout. FT00 FF00 FT FF RX0 RF0 FT FF FT0 FF0 FT FF " (.) /" (.) Min. FRME WIDTH SS Optional Steel Stiffener SS Optional Steel Stiffener / (.) HC00 Optional Head nchor FT FF M- FRME HEIGHT M- FT FH FT FF FT00 FF00 NOT TO SCLE /" (.) Min. Exterior Glazing Online usalum.com y Phone (00) - Online crlaurence.com y Phone (00) -

35 - FLUSH IN / FLUSH OUT FOR " () GLZING NOTE: Part numbers shown are available in ' (. m) stock lengths. Visit usalum.com for more information. 0 TYPICL ELEVTION Series FF0 Series FT0 F T 0 0 Part Number prefix ending in "T" represents THERMLLY ROKEN parts. Thermal parts are in OLD print. Series FT0 details are typically shown. NOTE: NP E.P.D.M. Glazing Gaskets used on both sides of glazing throughout. EC0 Subsill's End Closure (Typ.) FT00 FF00 FT FF RX0 RF0 FT FF RX0 RF0 FT FF " (.) FT0 FF0 FT FF /" (.) Min. / (.) FRME WIDTH HC00 Optional Head nchor FT FF FT FF FRME HEIGHT M- M- M- FT FH FT FF FT00 FF00 M- M- FT FH 0 FT FF FT00 FF00 /" (.) Min. Exterior Glazing Online usalum.com y Phone (00) - Online crlaurence.com y Phone (00) - NOT TO SCLE

36 - DOOR FRMING NOTE: Doors are available in stock to accommodate " x " ( x ) and x " ( x ) door openings. Visit usalum.com for more information. Series FF0 Series FT0 NOTE: NP E.P.D.M. Glazing Gaskets used on both sides of glazing throughout. CENTER HUNG DOOR OFFSET HUNG DOOR FF FF FF00 Filler (Typ.) P-00 I-/ IM I-/ IM P-00 RX0 RF0 " (.) " (.) " (.) FF P-00 FF P-00 RX0 RF0 M-0 M-0 D-00 D-00 /" (.) Min. /" (.) /" (.) D.O. FF DS0 FF DS0 RX0 RF0 M-0 M-0 DT-0 DT-0 / (.) D.O. / (.) NOT TO SCLE Online usalum.com y Phone (00) - Online crlaurence.com y Phone (00) -

37 - DOOR FRMING Series FF0 Series FT0 NOTE: Doors are available in stock to accommodate " x " ( x ) and x " ( x ) door openings. Visit usalum.com for more information. NOTE: NP E.P.D.M. Glazing Gaskets used on both sides of glazing throughout. / (.) HC00 Optional Head nchor FT CENTER HUNG DOOR OFFSET HUNG DOOR M- " (.) 0U Closer With Offset rm 0º N.H.O. " (.) I-/ IM I-/ IM I-/ IM " (.) /" (.) J-00 J-00 /" DS0/ (.) MC0 /" (.) D0 J-00 D-0/ M-0 D-0/ M-0 D-0/ M-0 D.O. D.O. M-0/ D-0 M-0/ D-0 Door Sweep With Concealed Fasteners M-0/ D-0 Door Sweep With Concealed Fasteners /" (.) /" (.) W00 /" (.) W00 / (.) TH0 / (.) TH0 / (.) Online usalum.com y Phone (00) - Online crlaurence.com y Phone (00) - TH0 NOT TO SCLE

38 - VERTICL CORNER CONDITIONS FOR " () GLZING Series FF0 Series FT0 F T 0 0 NOTE: Use also for Series FF00 with IS dapter for /" glass NOTE: NP E.P.D.M. Glazing Gaskets used on both sides of glazing throughout. 0 DEGREE CORNERS FT0 FF0 Part Number prefix ending in "T" represents THERMLLY ROKEN parts. Thermal parts are in OLD print. Series FT0 details are typically shown. FT0 FF0 FT0 FF0 DIMENSION POINTS FT FF " (.) " (.) DIMENSION POINTS NOTE: Use also for Series FF00 with RF00 Fillers for /" glass DEGREE CORNERS RF0 FT FF RF0 RF0 FT FF RF0 -/" (0.) DIMENSION POINTS -/" (.0) DIMENSION POINTS Corner of Vertical Corner of Vertical NOT TO SCLE Online usalum.com y Phone (00) - Online crlaurence.com y Phone (00) -

39 - TRNSITION GLZING FOR " () ND /" () GLZING Series FF0 Series FT0 NOTE: Part numbers shown are available in ' (. m) stock lengths. Visit usalum.com for more information. 0 0 F T 0 0 Part Number prefix ending in "T" represents THERMLLY ROKEN parts. Thermal parts are in OLD print. Series FT0 details are typically shown. NOTE: NP E.P.D.M. Glazing Gaskets used on both sides of glazing throughout. FLUSH-OUT FLUSH-IN FLUSH-IN / FLUSH-OUT FT FT RX0 RF0 FF RX0 RF0 FF FT FF FT FF IS IS M- M- IS IS IS IS IS M- FT FH FT FH RX0 RF0 FT FF RX0 RF0 FT FF M- FT M- FT FH FT FH IS FF IS M- IS RX0 RF0 FT FF RX0 RF0 IS 0 M- IS FF FT00 FF00 FF IS FT00 FF00 Exterior Glazing Online usalum.com y Phone (00) - Online crlaurence.com y Phone (00) - NOT TO SCLE

40 0- Windload Charts VERTICL MULLIONS FOR " () GLZING Series FF0 Series FT0 Mullions designed for L/ deflection ratio and for the following allowable working stresses: luminum alloy 0-T: allowable stress for windload, psi. ( MPa) Steel reinforcing: allowable stress for windload, psi ( MPa) Curves represent the limit values and are based on criteria for simple beam, uniformly loaded, using the distribution of wind forces on the wall with rectangular loading. Glass is not considered as contributing to resistance of deflection. Limitation of vertical mullions for: CURVES = PSF ( Pa) CURVES = 0 PSF ( Pa) CURVES C = PSF ( Pa) CURVES D = 0 PSF ( Pa) FT/RX0 or FF/RF0 I =. (. x 0 ) S =. (. x 0 ) SS Steel Stiffener I =. (. x 0 ) S =. (. x 0 ) IL+STL =. (. x 0 ) FT0/FT or FF0/FF I =. ( x 0 ) S =. (. x 0 ) SS Steel Stiffener I =.0 (. x 0 ) S =.0 (. x 0 ) IL+STL =. (. x 0 ) FF/RX0 or FF/RF0 I =. (0. x 0 ) S =. (. x 0 ) /" x " Steel ar I =.0 (0. x 0 ) S =.0 (. x 0 ) IL+STL =. (0. x 0 ) () (.) () (.) () 0 () (.) () (.) () Mullion Height in Feet (meters) C 0 D (.) () (.) () (.) FT/RX0 FF/RF0 C D (.) () (.) () (.) FT/RX0 FF/RF0 With SS Mullion Spacing in Feet (meters) Online usalum.com y Phone (00) - Online crlaurence.com y Phone (00) -

41 - Windload Charts VERTICL MULLIONS FOR " () GLZING Series FF0 Series FT0 Limitation of vertical mullions for: CURVES = PSF ( Pa) CURVES = 0 PSF ( Pa) CURVES C = PSF ( Pa) CURVES D = 0 PSF ( Pa) () (.) () (.) 0 () (.) () (.) () Mullion Height in Feet (meters) C D 0 () (.) () (.) () FT0/FT FF0/FF C D (.) () (.) () (.) FT0/FT FF0/FF With SS Mullion Spacing in Feet (meters) () (.) () (.) 0 () (.) () (.) () Mullion Height in Feet (meters) C D 0 () (.) () (.) () FF/RX0 FF/RF0 C D (.) () (.) () (.) FF/RX0 FF/RF0 With /" x " Steel ar Mullion Spacing in Feet (meters) Online usalum.com y Phone (00) - Online crlaurence.com y Phone (00) -

42 - Deadload Charts INTERMEDITE HORIZONTL MULLIONS FOR " () GLZING Series FF0 Series FT0 Deadload charts are based on /" (.) maximum allowable deflection at the center point of the horizontal mullion and on a glass weight of. psf (. Kg/m ) Glass shall rest on two setting blocks located at: CURVES : / points CURVES : / points or " (0.) from corners, whichever is larger 0 () (.) () (.) () (.) () (.) () () 0 () Height of Glass in Feet (meters) (.) () (.) () (.) FT FH Iyy =.0 (. x 0 ) 0 (.) () (.) () (.) FT FH Iyy =. (. x 0 ) Mullion Span in Feet (meters) DOOR HEDERS Deadload charts for door headers are based on /" (.) maximum allowable deflection at the center point of the header and on a glass weight of. psf (. Kg/m ) Glass shall rest on two setting blocks located at: CURVES : / points CURVES : / points or " (0.) from corners, whichever is larger 0 (.) () (.) () () Height of Glass in Feet (meters) Mullion Span in Feet (meters) J-00 Iyy =. (.0 x 0 ) Online usalum.com y Phone (00) - Online crlaurence.com y Phone (00) - 0 (.) () (.) () (.)

43 - ccessories Series FF0 Series FF Series FT Series FF00 Series FF0 Series FT0 PRT NO. DETIL DESCRIPTION PKG. QTY. WHERE USED FF0 FF FT FF00 FF0 FT0 EC0 End Dam 0 EC0 End Dam 0 SV00 Splice Sleeve 0 SV00 Splice Sleeve 0 CP0 Closure Plate for Verticals 0 CP0 Closure Plate for Verticals 0 WD0 Water Deflector for Shallow Pocket 0 WD0 Water Deflector for Deep Pocket 0 WD0 Water Deflector for Shallow Pocket 0 WD00 Water Deflector for Deep Pocket 0 Online usalum.com y Phone (00) - Online crlaurence.com y Phone (00) -

44 - ccessories Series FF0 Series FF Series FT Series FF00 Series FF0 Series FT0 PRT NO. DETIL DESCRIPTION PKG. QTY. WHERE USED FF0 FF FT FF00 FF0 FT0 S S0 S0 S00 Setting lock for Interior Glazing Setting lock for Exterior Glazing Setting lock for Interior Glazing Setting lock for Exterior Glazing W "W" Edge lock 0 HC00 Optional Head nchor 0 HC00 Optional Head nchor 0 DJ Drill Jig DJ Drill Jig DJ Drill Jig DJ Drill Jig Online usalum.com y Phone (00) - Online crlaurence.com y Phone (00) -

45 0- ccessories GLZING GSKET CHRT FOR STOREFRONT PRODUCTS Glazing Gaskets SYSTEM SERIES GLSS THICKNESS OUTSIDE GLZING INSIDE GLZING POCKET EXTERIOR INTERIOR EXTERIOR INTERIOR WIDTH DPTOR 00/00-S 0/0-S FF0 FF00 /-S IT FF FT FF0 FT0 /" () NP NP NP NP /" () NP NP NP NP /" () NP NP NP NP /" (0) NP NP NP NP /" () NP NP NP NP /" () NP NP NP NP /" () NP NP NP NP / () NP NP NP NP /" () NP NP NP NP /" () NP NP NP NP /" (.) /" (.) IS /" (.) IS00 /" () NP NP NP NP /" () NP NP NP NP " () NP NP NP NP -/" () NP NP NP NP -/" (.) -/" () NP NP NP NP / (.) / (.) /" (.) PRT NO. NP COLOR lack TYPE Interior/ Exterior ROLL LENGTH 00' (. m) PRT NO. NP COLOR lack TYPE Interior/ Exterior ROLL LENGTH 00' (. m) PRT NO. NP COLOR lack TYPE Exterior Heavy Gasket ROLL LENGTH 0' (. m) Minimum order: roll. Minimum order: roll. Minimum order: roll. djustable Multi-Cutter Tool Makes Precise Straight or Miter Cuts in Gaskets djustable Guide lock / (.) PRT NO. MC0N MC0R DESCRIPTION Multi-Cutter Pack of lades PRT NO. NP COLOR lack TYPE Universal Storefront Gasket ROLL LENGTH 00' (. m) Minimum order: each or pack. Online usalum.com y Phone (00) - Online crlaurence.com y Phone (00) - Minimum order: roll.

46 0- Miscellaneous Framing DIVISION RS SHOWN WITH /" () GLZING TYPICL VERTICL MEMERS Typ. MS0 /" - 0 x " M.S. MS /" - 0 x M.S. -/" (.) -/" (.) -/" (.) -/" (.) -/" (.) D0/ D0 D0/ D D-0/ D0/ D0 D-0/ D0/ D D-/ D0/ D HORIZONTL MEMERS -/" (.) -/" (.) S0 " (0.) Setting lock -/" (.) D-0/ D0 D0/ S0 " (0.) Setting lock D-0/ D0 D D-/ D0 D0/ S0 " (0.) Setting lock CORNER MEMERS D0 D D0 D C0 C0 C0 C0 DEGREE CORNER DEGREE CORNER 0 DEGREE CORNER 0 DEGREE CORNER NOTE: ll stocks lengths on this page are available in clear anodized or bronze anodized finishes, and are ' (. m) in length unless noted otherwise. Visit usalum.com for more information. NOT TO SCLE Online usalum.com y Phone (00) - Online crlaurence.com y Phone (00) -

47 0- Miscellaneous Framing RS ND NGLES -/ (.) / (.) /" (.) -0 - /" (.) / (.) / (.) /" (.) /" (.) /" (.) /" (.) " (.) " (.) /" (.) -/" (.) -/" (.) /" (.) -/ (.) -/ (.) /" (.) -00 L TUES " (.) " (.) " (0.) J- J-00 J-0 J-00 J-00 ' (. m) -/ (.) -/ (.) " () " (.) J-0 I-0 J-00 J-00 ' (. m) ' (. m) ' (. m) ' (. m) SILL COVERS ND JM MOLDINGS /" (.) /" (.) -/" (.) -/" (.) -/" (.) -/" (.) SC00 SC00 SC00 SJ00 NOTE: ll stock lengths on this page are available in clear anodized or bronze anodized finishes, and are ' (. m) in length unless noted otherwise. Visit usalum.com for more information. NOT TO SCLE Online usalum.com y Phone (00) - Online crlaurence.com y Phone (00) -

48 0- ccessories STEEL STIFFENERS* PRIMED HOT ROLLED COMMERCIL QULITY, STM - Steel Stiffeners and Drill Jigs DRILL JIGS PRT NO. DETIL DESCRIPTION STOCK LENGTH PRT NO. TO PREPRE FOR SYSTEM PKG. QTY. SS00 -/" () x /" () x G. Use with Series 00 and 00-S ' (. m) DJ00 Verticals Screw Spline Center Glaze Series 00 and Series 0 SS SS0 -/ (.) x -/" (.) x G. Use with Series 00 and 00-S -/" (0.) x /" () x G. Use with Series 0 and ' (. m) ' (. m) DJ0 DJ DJ DJ0 Verticals Verticals Verticals Verticals Shear lock Screw Spline and Shear lock Screw Spline Shear lock Center Glaze Series 00-S and Series 0-S Center Glaze Series and Series -S Center Glaze Series IT SS -/" (.) x -/" (.) x 0 G. Use with Flush Front FF ' (. m) DJ Verticals Screw Spline Flush Front Series FF0 SS -/ (.) x -/ (.) x 0 G. Use with Flush Front FF0/FF ' (. m) DJ Verticals Screw Spline Flush Front Series FF Series FT SS -/" () x -/" (0.) x 0 G. Use with Flush Front FF/FT ' (. m) DJ Verticals Horiz. Flush Front Series FF00 SS x -/" (.) x 0 G. Use with Flush Front FF0/FF/FT0/FT ' (. m) DJ Verticals Horiz. DJ0 Verticals P and P Flush Front Series FF0 Series FT0 OS- Series OS0/0-SG and Series OS/-SG SS -/ (.) x -/" (.) x 0 G. Fits FF ' (. m) DJ0 Verticals P and P OS- Series OS00/00-SG and Series OS0/0-SG SS -/ (.) x -/" (.) x 0 G. Fits FF and FT ' (. m) DJ Verticals P G Systems Series G0 Series G Series T *Steel Stiffeners shown are the more popular models. For additional information on Stiffeners, contact U.S. luminum Technical Sales at (00) -. Online usalum.com y Phone (00) - Online crlaurence.com y Phone (00) -

WINDOW WALLS Table of Contents OS-2 Systems Series OS175/OS175SG

WINDOW WALLS Table of Contents OS-2 Systems Series OS175/OS175SG - Table of ontents OS- Systems Series OS/OSSG Series OS0/OS0SG Series OS/OSSG Series OS00/OS00SG Series OS0/OS0SG Section Page PROUT OVERVIEW.................................................. - and - TEHNIL

More information

Storefront Installation Guide

Storefront Installation Guide Storefront General Notes: 1. Check Contract Documents and Shop Drawings. Understand and clarify any Field Verify Notes and approvals of drawings and products to be familiar with the project. Installation

More information

SPECIFICATIONS...02-C3 and 03-C3 SPECIAL FEATURES...04-C3 and 05-C3 TECHNICAL DATA...06-C3 and 07-C3

SPECIFICATIONS...02-C3 and 03-C3 SPECIAL FEATURES...04-C3 and 05-C3 TECHNICAL DATA...06-C3 and 07-C3 0- Table of ontents SETION Series OS & OSSG Series OS0 & OS0SG Series OS & OSSG Series OS00 & OS00SG Series OS0 & OS0SG PGE SPEIFITIONS...0- and 0- SPEIL FETURES...0- and 0- TEHNIL T...0- and 0- Series

More information

1602 Wall System. Optional Features Deep covers available Deep and heavy-weight mullions

1602 Wall System. Optional Features Deep covers available Deep and heavy-weight mullions JULY, EC - Wall System FETURES Features Slim " (.) sight lines Tubular construction with shear block connections Split mullion unitized system for horizontal strip window Thermally improved framing Range

More information

INSTALLATION INSTRUCTIONS 2 x 4 1/2 for 1 Glass

INSTALLATION INSTRUCTIONS 2 x 4 1/2 for 1 Glass INSTALLATION INSTRUCTIONS 2 x 4 1/2 for 1 Glass Deep pocket allows for direct anchor attachment to substrate without flat filler plate. 1/4 Ø perimeter anchor holes allows for direct anchor attachment

More information

SECTION B INDEX STOREFRONT FRAMING SYSTEMS

SECTION B INDEX STOREFRONT FRAMING SYSTEMS SECTION B INDEX STOREFRONT FRAMING SYSTEMS B PAGE DESCRIPTION 01 STOREFRONT FRAMING SPECIFICATIONS 02 175 SERIES 1 3/4" (44.5) X 4 1/2" (114.3) FLUSH GLAZE FRAMING FOR SINGLE GLAZING. 06 200 SERIES 2"

More information

INSTALLATION INSTRUCTIONS SIDELITE ASSEMBLY SERIES 900 TERRACE DOOR AND SERIES 925 PATIO DOOR

INSTALLATION INSTRUCTIONS SIDELITE ASSEMBLY SERIES 900 TERRACE DOOR AND SERIES 925 PATIO DOOR INSTALLATION INSTRUCTIONS SIDELITE ASSEMBLY SERIES 900 TERRACE DOOR AND SERIES 925 PATIO DOOR Phone: (800) 262-5151 Fax: (866) 262-3299 crlaurence.com usalum.com crl-arch.com 11M0292 HANDLING, STORAGE,

More information

2.01 Standard Entrances Description

2.01 Standard Entrances Description 2.01 Standard Entrances Description Description Tubelite Standard Entrances have an outstanding reputation for craftsmanship and strength. The Narrow Stile Door has a face dimension of 2 1/8" and is designed

More information

ELEPHANT DOOR SYSTEMS SERIES E1200

ELEPHANT DOOR SYSTEMS SERIES E1200 INSTALLATION INSTRUCTIONS ELEPHANT DOOR SYSTEMS SERIES E1200 Phone: (800) 262-5151 Fax: (866) 262-3299 crlaurence.com usalum.com crl-arch.com AVDB3096 03.13 TABLE OF CONTENTS SUBJECT PAGE GENERAL INSTALLATION

More information

14000 I/O Series Flush Glaze. Fabrication and Installation Instructions

14000 I/O Series Flush Glaze. Fabrication and Installation Instructions 14000 I/O Series Flush Glaze Fabrication and Installation Instructions Last saved on 12/18/2009 Table of Contents GENERAL CONSTRUCTION NOTES...3 EXTRUDED ALUMINUM PARTS...4 ACCESSORIES...5 OVERVIEW...6

More information

INSTALLATION INSTRUCTIONS SERIES 487 CENTER GLAZED WITH 1-1/2" TRIM OFFICE PARTITIONS

INSTALLATION INSTRUCTIONS SERIES 487 CENTER GLAZED WITH 1-1/2 TRIM OFFICE PARTITIONS INSTALLATION INSTRUCTIONS SERIES 87 CENTER GLAZED WITH -/" TRIM OFFICE PARTITIONS Phone: (800) -6 Fax: (800) 58-7 crlaurence.com usalum.com crl-arch.com M056_Rev_D SERIES 87 OFFICE PARTITIONS CENTER GLAZED

More information

SERIES BW3250 BLAST WALL TABLE OF CONTENTS INSTALLATION INSTRUCTIONS GENERAL NOTES

SERIES BW3250 BLAST WALL TABLE OF CONTENTS INSTALLATION INSTRUCTIONS GENERAL NOTES I N S TA L L AT I O N I N S T R U C T I O N S BW3250 BLAST RESISTANT CURTAIN WALL Page 2 SERIES BW3250 BLAST WALL TABLE OF CONTENTS United States Aluminum PAGE GENERAL NOTES...2 and 3 FABRICATION...4 through

More information

INSTALLATION INSTRUCTIONS 2 1/2 x 7 for 1 Glass

INSTALLATION INSTRUCTIONS 2 1/2 x 7 for 1 Glass INSTALLATION INSTRUCTIONS 2 1/2 x 7 for 1 Glass Captured System 3010 Rice Mine Road, Tuscaloosa, Alabama 35406 1-800-772-7737 Fax 1-800-443-6261 www.coralind.com A Division of Coral Industries, Inc. B.G.

More information

4500 Series. Fabrication and Installation Instructions

4500 Series. Fabrication and Installation Instructions 4500 Series Fabrication and Installation Instructions E4500 Series July, 2017 Table of Contents GENERAL CONSTRUCTION NOTES... 3 EXTRUDED ALUMINUM PARTS... 5 ACCESSORIES... 7 OVERVIEW... 8 FRAME FABRICATION...

More information

Storefront Installation Guide INSTALLATION INSTRUCTIONS

Storefront Installation Guide INSTALLATION INSTRUCTIONS STOREFRONT General Notes 1. Check contract documents and shop drawings, and understand and clarify any Field Verify Notes, approvals of drawings, and products required to be familiar with the project.

More information

Illustration Part Description Base List Weight/ Ft./ Box Number Price/S.L. S.L. S.L. Qty.

Illustration Part Description Base List Weight/ Ft./ Box Number Price/S.L. S.L. S.L. Qty. Prices DO NOT include glazing gaskets or weathering. See Accessories sheet. Exterior Glazed Back Members for 1" Glass Illustration Part Description Base List Weight/ Ft./ Box Price/S.L. S.L. S.L. Qty.

More information

14000 Series. Fabrication and Installation Instructions

14000 Series. Fabrication and Installation Instructions 14000 Series Fabrication and Installation Instructions Revision May 2013 Table of Contents GENERAL CONSTRUCTION NOTES...3 EXTRUDED ALUMINUM PARTS...5 ACCESSORIES...8 OVERVIEW...10 FRAME FABRICATION...15

More information

14000 Series. Fabrication and Installation Instructions

14000 Series. Fabrication and Installation Instructions 14000 Series Fabrication and Installation Instructions 14000 Series Revision December 01, 2009 Table of Contents GENERAL CONSTRUCTION NOTES... 3 EXTRUDED ALUMINUM PARTS... 4 ACCESSORIES... 7 OVERVIEW...

More information

DHS-500 IMPACT SYSTEM INSTALLATION MANUAL

DHS-500 IMPACT SYSTEM INSTALLATION MANUAL DHS-500 IMPACT SYSTEM INSTALLATION MANUAL TABLE OF CONTENTS SECTION PAGE GENERAL NOTES 3 EXTRUSION & PARTS IDENTIFICATION 4-5 DETERMINE FRAME SIZE 6 FABRICATE VERTICAL MULLIONS & FILLERS 7-8 FABRICATE

More information

YES 40 FS/FI Storefront System Installation Manual

YES 40 FS/FI Storefront System Installation Manual Installation Manual 2014 YKK AP America Inc. is a subsidiary of YKK Corporation of America. TABLE OF CONTENTS Installation Notes... Page ii PARTS DESCRIPTION YES 40 FS Framing Members... Page 1 YES 40

More information

GENERAL INSTALLATION GUIDELINES

GENERAL INSTALLATION GUIDELINES 1551 MT. ROSE AVENUE YORK PA 17403-2909 (717) 849-8100 GENERAL INSTALLATION GUIDELINES For Receptor Systems Approved 08/31/2018 Installation Guideline Disclaimer This document contains general installation

More information

Flushglaze For Framed Openings and Horizontal Panels. Window System Installation Guide

Flushglaze For Framed Openings and Horizontal Panels. Window System Installation Guide Flushglaze 4500 For Framed Openings and Horizontal Panels Window System Installation Guide January 2017 BENCHMRK Welcome to Kingspan, global leaders in the design and manufacture of insulated metal panels

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS Thermally Broken Framing and Door Installation SL-450TB (2" x 4-1/2" with 1" Glazing) & SL-600TB (2" x 6" with 1" Glazing) IMPORTANT: Read all instructions before beginning installation.

More information

Thermally Broken Framing and Door Installation

Thermally Broken Framing and Door Installation INSTALLATION INSTRUCTIONS Thermally Broken Framing and Door Installation IMPORTANT: Read all instructions before beginning installation. These instructions are provided to help prevent installation problems

More information

YES 45 TU Thermal Storefront System Installation Manual

YES 45 TU Thermal Storefront System Installation Manual Installation Manual 2004 YKK AP America Inc. is a subsidiary of YKK Corporation of America. TABLE OF CONTENTS Installation Notes........................................ Page ii PARTS DESCRIPTION Framing

More information

InFrame TM Interior Framing System

InFrame TM Interior Framing System JANUARY, 2017 InFrame TM Interior Framing System FEATURES 1 Features x 6" sightline, interior partition framing Flush glazed, center plane glass application Screw spline fabrication 1/8", 1/4", and 3/8"

More information

INSTALLATION INSTRUCTIONS TRIFAB VG SCREW SPLINE ASSEMBLY TRIFAB VG 450 TRIFAB VG 451 TRIFAB VG 451T

INSTALLATION INSTRUCTIONS TRIFAB VG SCREW SPLINE ASSEMBLY TRIFAB VG 450 TRIFAB VG 451 TRIFAB VG 451T INSTALLATION TRIFAB VG SCREW SPLINE ASSEMBLY TRIFAB VG 450 TRIFAB VG 451 TRIFAB VG 451T INSTRUCTIONS LITHO IN U.S.A. JANUARY KAWNEER COMPANY, INC., 2004 451-VG-970.01.04a PART NO. 451-VG-970 1 INSTALLATION

More information

GENERAL INSTALLATION GUIDELINES

GENERAL INSTALLATION GUIDELINES 1551 MT. ROSE AVENUE YORK PA 17403-2909 (717) 849-8100 GENERAL INSTALLATION GUIDELINES For Receptor Systems Approved 9/29/2017 Installation Guideline Disclaimer This document contains general installation

More information

YCW 750 IG Inside Glazed Curtain Wall System Installation Manual

YCW 750 IG Inside Glazed Curtain Wall System Installation Manual Installation Manual 2014 YKK AP America Inc. is a subsidiary of YKK Corporation of America. TABLE OF CONTENTS Installation Notes... Page ii PARTS DESCRIPTION YCW 750 IG Framing Members... Page 1 to 3

More information

Interior framing system Integrated entrance framing allowing Kawneer standard entrances or other specialty entrances to be incorporated

Interior framing system Integrated entrance framing allowing Kawneer standard entrances or other specialty entrances to be incorporated JULY, 2014 InFrame TM FEATURES 1 Features x 6" sightline, interior partition framing Flush glazed, center plane glass application Screw spline fabrication 1/8", 1/4", and 3/8" infill options Permanodic

More information

Note: Installation and Glazing Manuals are product specific. FOR REVIEW ONLY! May 2015

Note: Installation and Glazing Manuals are product specific. FOR REVIEW ONLY! May 2015 Note: Installation and Glazing Manuals are product specific. FOR REVIEW ONLY! May 2015 Phone: 1-866-OLDCASTLE (653-2278) Web Address: www.oldcastlebe.com S E R I E S 6 0 0 0 X T - S T O R E F R O N T I

More information

FG-5100T STORMMAX INSTALLATION AND GLAZING MANUAL NOTE:

FG-5100T STORMMAX INSTALLATION AND GLAZING MANUAL NOTE: BuildingEnvelope R FG-5100T STORMMAX INSTALLATION AND GLAZING MANUAL NOTE: THE INSTALLATION DETAILS FOUND IN THIS PACKAGE ARE GENERIC AND ARE FOR REPRESENTATION ONLY WITH THE INTENT OF GIVING THE INSTALLATION

More information

YWE 40 T Window Wall System Installation Manual

YWE 40 T Window Wall System Installation Manual Installation Manual 2005 YKK AP America Inc. is a subsidiary of YKK Corporation of America. TABLE OF CONTENTS Installation Notes........................................ Page ii Frame Types............................................

More information

Installation Instructions

Installation Instructions Installation Instructions 200 Series Curtainwall 3056 WALKER RIDGE DR. NW, SUITE G WALKER, MI 49544 800-866-2227 dependable@tubeliteinc.com Revised April 2014 dependable@tubeliteinc.com Page 1 TABLE OF

More information

Series 406 storefront. Installation Instructions

Series 406 storefront. Installation Instructions Series 406 storefront Installation Instructions Part NO. Y016 February 2013 Series 406 Installation Instructions TABLE OF CONTENTS Section I GENERAL NOTES Page 1 II PARTS IDENTIFICATION Page 2-3 III FABRICATION

More information

b. B aluminum and aluminum-alloy extruded bar, rod, wire, shape and tube

b. B aluminum and aluminum-alloy extruded bar, rod, wire, shape and tube MODEL 240I SECTION 08120 FLUSH ALUMINUM DOORS AND FRAMES PART I GENERAL 1.01 SCOPE OF WORK A. Furnish all labor, materials, equipment and incidentals required to deliver and install aluminum doors, frames,

More information

SECTION C1 INSTALLATION INSTRUCTIONS

SECTION C1 INSTALLATION INSTRUCTIONS SECTION C1 SERIES CWW451T THERMALLY BROKEN FRONT GLAZED WINDOW WALL / STOREFRONT SYSTEM X 4 1 / for 1" GLAZING INSTALLATION INSTRUCTIONS EXTERIOR GLAZED Effective October 2014 www.cardcompro.com 1 INTERIOR

More information

Series 526 Thermal impact storefront. Installation Instructions

Series 526 Thermal impact storefront. Installation Instructions Series 526 Thermal impact storefront Installation Instructions Part NO. Y021 February 2013 TABLE OF CONTENTS SECTION PAGE I. General Notes and Guidelines. 3 II. Parts Identification Chart.......4-8 III.

More information

INSTALLATION INSTRUCTIONS TRIFAB 451UT SCREW SPLINE ASSEMBLY TRIFAB 451UT. AUGUST, 2010 (Part No. 452T-CG-970) EC

INSTALLATION INSTRUCTIONS TRIFAB 451UT SCREW SPLINE ASSEMBLY TRIFAB 451UT. AUGUST, 2010 (Part No. 452T-CG-970) EC AUGUST, 2010 (Part No. 452T-CG-970) EC 97904-31 1 INSTALLATION SCREW SPLINE ASSEMBLY Kawneer Company, Inc., 2010 INSTRUCTIONS 2 TABLE OF CONTENTS (452T-CG-970) AUGUST, 2010 These instructions show the

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS 400T SERIES CURTAIN WALL INSTALLATION INSTRUCTIONS 3056 Walker Ridge Dr. NW, Suite G Walker, MI 49544 800-866-2227 October 2017 www.tubeliteinc.com Page 1 BLANK Page 2 www.tubeliteinc.com October 2017

More information

350/500 HEAVY WALL TM IR ENTRANCES 1

350/500 HEAVY WALL TM IR ENTRANCES 1 JUNE, 202 30/00 HEAVY WALL TM IR ENTRANCES FEATURES Blast Mitigation Product Features 30 medium stile has 3-/2" vertical stile, 3-/2" top and 6-/2" bottom rail 00 wide stile has " vertical stile, " top

More information

YSG 40/50/50T Window Wall System Installation Manual

YSG 40/50/50T Window Wall System Installation Manual Installation Manual 2004 YKK AP America Inc. is a subsidiary of YKK Corporation of America. TABLE OF CONTENTS Installation Notes........................................ Page ii PARTS DESCRIPTION YSG 40

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS 900 SERIES RIBBON WINDOW INSTALLATION INSTRUCTIONS 3056 Walker Ridge Dr. NW, Suite G Walker, MI 49544 800-866-2227 November 2016 www.tubeliteinc.com Page 1 TABLE OF CONTENTS GENERAL CONSTRUCTION NOTES...3-4

More information

SERIES 2100/2200 CURTAIN WALL

SERIES 2100/2200 CURTAIN WALL INSTALLATION INSTRUCTIONS SERIES 2100/2200 CURTAIN WALL Phone: (800) 262-5151 Fax: (866) 262-3299 crlaurence.com usalum.com crl-arch.com 11M0173 HANDLING, STORAGE, AND PROTECTION OF The following precautions

More information

YCW 750 OG Outside Glazed Curtain Wall System Installation Manual

YCW 750 OG Outside Glazed Curtain Wall System Installation Manual YCW 750 OG Outside Glazed Curtain Wall System Installation Manual 2004 YKK AP America Inc. is a subsidiary of YKK Corporation of America. TABLE OF CONTENTS Installation Notes........................................

More information

YES 600 Thermal Clip Storefront System Installation Manual

YES 600 Thermal Clip Storefront System Installation Manual Installation Manual 2004 YKK AP America Inc. is a subsidiary of YKK Corporation of America. TABLE OF CONTENTS Installation Notes........................................ Page ii Frame Types............................................

More information

Architectural Testing AAMA 501 TEST REPORT. Report Number: C Rendered to: Tubelite, Inc. Walker, Michigan

Architectural Testing AAMA 501 TEST REPORT. Report Number: C Rendered to: Tubelite, Inc. Walker, Michigan Architectural Testing AAMA 501 TEST REPORT Report Number: C1529.01-450-44 Rendered to: Tubelite, Inc. Walker, Michigan MODEL DESIGNATION: E4500 PRODUCT TYPE: Non-Thermal Storefront This report contains

More information

SECTION BULLET- RESISTANT DOORS

SECTION BULLET- RESISTANT DOORS 1 SECTION 08 3950 BULLET- RESISTANT DOORS PART 1- GENERAL 1.01 SUMMARY A. This Section Includes: 1. Bullet- resistant steel door and frame systems. 2. Door hardware for bullet- resistant steel door and

More information

Series 525 impact storefront. Installation Instructions

Series 525 impact storefront. Installation Instructions Series 525 impact storefront Installation Instructions Part NO. Y020 February 2013 SECTION I GENERAL NOTES II PARTS IDENTIFICATION III FABRICATION A. DRILLING TEMPLATE (SCREW SPLINE VERTICALS) B. DRILLING

More information

350/500 Heavy Wall TM IR Entrances

350/500 Heavy Wall TM IR Entrances SEPTEMBER, 207 FEATURES Hurricane Resistant Product Blast Mitigation Product Features 50 Heavy Wall TM IR medium stile has vertical stiles, top and 6-/ (65.) bottom rails 500 Heavy Wall TM IR wide stile

More information

YES 45 FS/FI Storefront System Installation Manual

YES 45 FS/FI Storefront System Installation Manual Installation Manual 2014 YKK AP America Inc. is a subsidiary of YKK Corporation of America. TABLE OF CONTENTS Installation Notes... Page ii PARTS DESCRIPTION YES 45 FS Framing Members... Page 1 YES 45

More information

SERIES 2100/2200 CURTAIN WALL

SERIES 2100/2200 CURTAIN WALL INSTALLATION INSTRUCTIONS SERIES 2100/2200 CURTAIN WALL Phone: (800) 262-5151 Fax: (866) 262-3299 crlaurence.com usalum.com crl-arch.com 11M0173 HANDLING, STORAGE, AND PROTECTION OF The following precautions

More information

SCI-FAB Product Specifications. Casework Section 1. Part 1 General

SCI-FAB Product Specifications. Casework Section 1. Part 1 General SCI-FAB Product Specifications Casework Section 1 Part 1 General 1.1 SCOPE OF WORK Includes all factory fabricated stainless steel casework as required by the project drawings. 1.2 TYPICAL INCLUSIONS A.

More information

350 IR ENTRANCES INDEX

350 IR ENTRANCES INDEX 50 IR ENTRANCES INDEX Hurricane Resistant Product PICTORIAL VIEW... IR 500 ENTRANCE FRAMING DETAILS... 4 IR 50 ENTRANCE FRAMING DETAILS... 5 TRIFAB VG 450 FRAMES / 600 WALL SUB-FRAMES...6 INFILL OPTIONS

More information

INSTALLATION INSTRUCTIONS. Thermal Entrances AA 250/AA 425 THERMAL DOOR WITH TRIFAB 601/601T FRAMING

INSTALLATION INSTRUCTIONS. Thermal Entrances AA 250/AA 425 THERMAL DOOR WITH TRIFAB 601/601T FRAMING JANUARY, 2014 1 INSTALLATION Thermal Entrances AA 250/AA 425 THERMAL DOOR WITH TRIFAB 601/601T FRAMING INSTRUCTIONS 2 FRAME ASSEMBLY JANUARY, 2014 601442 SHEAR BLOCK BALL BEARING NRP BUTT (FACTORY APPLIED

More information

Series Sloped glazed Curtain wall. Installation Instructions

Series Sloped glazed Curtain wall. Installation Instructions Series 5600 Sloped glazed Curtain wall Installation Instructions Part NO. Y308 February 2013 SECTION TABLE OF CONTENTS PAGE I. General Notes & Guidelines. 3-4 II. Gutter and Mullion Assembly.. 5 III. End

More information

SERIES CF450 INSTALLATION INSTRUCTIONS. SERIES CF450 1¾ x 4½ - B1. Fabrication for Panel Assembly. High Performance Non-Thermal Storefront System

SERIES CF450 INSTALLATION INSTRUCTIONS. SERIES CF450 1¾ x 4½ - B1. Fabrication for Panel Assembly. High Performance Non-Thermal Storefront System SERIES CF450 INSTALLATION INSTRUCTIONS Fabrication for Panel Assembly High Performance Non-Thermal Storefront System Effective October 2014 www.cardcompro.com 1 2 www.cardcompro.com Effective October 2014

More information

Heavy Wall Applied Stop Tube Frame and Door Installation

Heavy Wall Applied Stop Tube Frame and Door Installation INSTALLATION INSTRUCTIONS Heavy Wall Applied Stop Tube Frame and Door Installation Read all instructions before beginning installation. These instructions are provided to help prevent installation problems

More information

40mm Thermoclick. Type II Class 1 Clear Satin Anodize - 201R1 (Mid Grade Commercial)

40mm Thermoclick.  Type II Class 1 Clear Satin Anodize - 201R1 (Mid Grade Commercial) http://www.sundancesupply.com 40mm Thermoclick Type II Class 1 Clear Satin Anodize - 201R1 (Mid Grade Commercial) U-Profile 12' Lengths $39 Out System offers a complete set of extrusions and accessories

More information

SERIES CF451T INSTALLATION INSTRUCTIONS. SERIES CF451T 2 x 4½ - B2. Fabrication for Panel Assembly. High Performance Thermal Storefront System

SERIES CF451T INSTALLATION INSTRUCTIONS. SERIES CF451T 2 x 4½ - B2. Fabrication for Panel Assembly. High Performance Thermal Storefront System SERIES CF451T INSTALLATION INSTRUCTIONS Fabrication for Panel Assembly High Performance Thermal Storefront System Effective October 2014 www.cardcompro.com 1 2 www.cardcompro.com Effective October 2014

More information

Note: Installation and Glazing Manuals are product specific. FOR REVIEW ONLY! FEBRUARY 2012

Note: Installation and Glazing Manuals are product specific. FOR REVIEW ONLY! FEBRUARY 2012 Note: Installation and Glazing Manuals are product specific. FOR REVIEW ONLY! Phone: 1-866-OLDCASTLE (653-2278) Web Address: www.oldcastlebe.com FG-1000 & FG-2000 INSTALLATION & GLAZING INSTRUCTIONS These

More information

STANDARD ENTRANCES TECHNICAL MANUAL

STANDARD ENTRANCES TECHNICAL MANUAL TECHNICAL MANUAL FEATURES FEATURES Narrow stile doors have a 2 1/2" top rail, 3 7/16" bottom rail, and 2 1/16" vertical stiles Medium stile doors have a 3 7/16" top rail, 6 7/16" bottom rail, and 3 7/16"

More information

YCW 752 Outside Glazed Curtain Wall System Installation Manual

YCW 752 Outside Glazed Curtain Wall System Installation Manual YCW 752 Outside Glazed Curtain Wall System Installation Manual 2007 YKK AP America Inc. is a subsidiary of YKK Corporation of America. TABLE OF CONTENTS Installation Notes........................................

More information

Definitions and Design Considerations... W-CR-2

Definitions and Design Considerations... W-CR-2 General Information SECTION DIRECTORY Definitions and Design Considerations... W-CR-2 Combination Assembly Recommendations and Limitations Typical Sealant... W-CR-4 Single-Unit Opening... W-CR-4 Two-Way

More information

INSTALLATION INSTRUCTIONS. EnCORE CAPTURED & SSG SCREW SPLINE SHEAR BLOCK TYPE B LITHO IN U.S.A. JANUARY KAWNEER COMPANY, INC

INSTALLATION INSTRUCTIONS. EnCORE CAPTURED & SSG SCREW SPLINE SHEAR BLOCK TYPE B LITHO IN U.S.A. JANUARY KAWNEER COMPANY, INC INSTALLATION EnCORE CAPTURED & SSG SCREW SPLINE SHEAR BLOCK TYPE B INSTRUCTIONS LITHO IN U.S.A. JANUARY KAWNEER COMPANY, INC. 2004 175-970.01.04 PART NO. 175-970 INSTALLATION INSTRUCTIONS CONTENTS These

More information

SERIES 300 SINGLE HUNG WINDOW INSTALLATION

SERIES 300 SINGLE HUNG WINDOW INSTALLATION IMPORTANT INFORMATION: WHETHER IT BE LOCATION OR INSTALLATION TYPE, NOT ALL WINDOW TYPES CAN BE INSTALLED IN ALL AREAS OR WALL CONDITIONS. CONSULT YOUR LOCAL BUILDING CODE DEPARTMENT FOR ANY REGULATIONS

More information

SERIES 406X. Installation Instructions. Place photography here. Don t go over grey area. (size w x h )

SERIES 406X. Installation Instructions. Place photography here. Don t go over grey area. (size w x h ) SERIES 406X Installation Instructions Place photography here. Don t go over grey area (size 7.9961 w x 7.4561 h ) Table of Contents Section 1. General Notes and Guidelines. 2. Parts Identification Charts

More information

YCW 750 OG Outside Glazed Curtain Wall System Installation Manual

YCW 750 OG Outside Glazed Curtain Wall System Installation Manual YCW 750 OG Outside Glazed Curtain Wall System Installation Manual 2012 YKK AP America Inc. is a subsidiary of YKK Corporation of America. TABLE OF CONTENTS Installation Notes... Page ii PARTS DESCRIPTION

More information

1010 Sliding Mall Front

1010 Sliding Mall Front JUNE, 2018 FEATURES 1 Features Screw spline fabrication 1/4" and 1" glazing Permanodic TM anodized finishes in seven standard choices Painted finishes in forty-two standard choices and unlimited custom

More information

Series 9000 Vinyl Single Hung

Series 9000 Vinyl Single Hung Series 9000 Single Hung Series 9000 Vinyl Single Hung Contents List of Architectural Drawings...9000SH - 3 Elevations - Single Hung...9000SH - 4 Available Sizes - Single Hung...9000SH - 5 Elevations -

More information

CRL JACKSON 900 SERIES

CRL JACKSON 900 SERIES INSTALLATION INSTRUCTIONS CRL JACKSON 900 SERIES FLOOR MOUNTED DOOR CLOSERS CENTER HUNG AND OFFSET crlaurence.com crlaurence.com MODEL No. 990 crlaurence.com Phone: (800) 421-6144 Fax: (800) 262-3299 crlaurence.com

More information

INSTALLATION INSTRUCTIONS FOR CECO DOOR FLOOD RESISTANT DOOR AND FRAME ASSEMBLIES

INSTALLATION INSTRUCTIONS FOR CECO DOOR FLOOD RESISTANT DOOR AND FRAME ASSEMBLIES INSTLLTION INSTRUCTIONS FOR CECO DOOR FLOOD RESISTNT DOOR ND FRME SSEMBLIES GENERL The installation of flood resistant door and frame assemblies differs significantly from that of standard door and frame

More information

METL-VISION WINDOW SYSTEM FOR HORIZONTAL WALL PIONEERING INSULATED METAL PANEL TECHNOLOGY

METL-VISION WINDOW SYSTEM FOR HORIZONTAL WALL PIONEERING INSULATED METAL PANEL TECHNOLOGY METL-VISION WINDOW SYSTEM FOR HORIZONTAL WALL Window assembly GUIDE PIONEERING INSULATED METAL PANEL TECHNOLOGY PIONEERING INSULATED METAL PANEL TECHNOLOGY CONTENTS DETAIL TITLE FILE NO. PAGE NO. INTRODUCTION..................................................................

More information

INSTALLATION INSTRUCTIONS. EnCORE CAPTURED & SSG SCREW SPLINE SHEAR BLOCK TYPE B. EnCORE FEBRUARY, 2012 EC PART NO.

INSTALLATION INSTRUCTIONS. EnCORE CAPTURED & SSG SCREW SPLINE SHEAR BLOCK TYPE B. EnCORE FEBRUARY, 2012 EC PART NO. FEBRUARY, 2012 1 INSTALLATION CAPTURED & SSG SCREW SPLINE SHEAR BLOCK TYPE B INSTRUCTIONS 2 FEBRUARY, 2012 INSTALLATION INSTRUCTIONS CONTENTS These instructions show the general installation sequence and

More information

Series 960 wall storefront. Installation Instructions

Series 960 wall storefront. Installation Instructions Series 960 wall storefront Installation Instructions Part NO. Y005 February 2013 960 WALL TALE OF CONTENTS JWH 8/2011 SECTION I II III GENERAL NOTES PARTS IDENTIFICATION SCREW SPLINE FARICATION PAGE 1

More information

INSTALLATION INSTRUCTIONS SERIES 3600 SUNSHADE SYSTEM

INSTALLATION INSTRUCTIONS SERIES 3600 SUNSHADE SYSTEM INSTALLATION INSTRUCTIONS SERIES 3600 SUNSHADE SYSTEM Phone: (800) 262-5151 Fax: (866) 262-3299 crlaurence.com usalum.com crl-arch.com 11M0103 HANDLING, STORAGE, AND PROTECTION OF The following precautions

More information

YES 45 XT High Performance Thermal Storefront System

YES 45 XT High Performance Thermal Storefront System Dual Thermal Barrier ThermaBond Plus Pour & Debridge Technology Installation Manual 2015 YKK AP America Inc. is a subsidiary of YKK Corporation of America. TABLE OF CONTENTS Installation Notes... Page

More information

SERIES 300 SINGLE HUNG WITH FIN WINDOW INSTALLATION

SERIES 300 SINGLE HUNG WITH FIN WINDOW INSTALLATION IMPORTANT INFORMATION: WHETHER IT BE LOCATION OR INSTALLATION TYPE, NOT ALL WINDOW TYPES CAN BE INSTALLED IN ALL AREAS OR WALL CONDITIONS. CONSULT YOUR LOCAL BUILDING CODE DEPARTMENT FOR ANY REGULATIONS

More information

Sun Control-Solar Eclipse-Solar Shelf

Sun Control-Solar Eclipse-Solar Shelf Sun Control-Solar Eclipse-Solar Shelf Note: Installation and Glazing Manuals are product specific. FOR REVIEW ONLY! TABLE OF CONTENTS GENERAL INFORMATION Product Use...Page 3 Protection and Storage...Page

More information

Versatrac R-System Stock Extrusions, Clips and Accessories

Versatrac R-System Stock Extrusions, Clips and Accessories Versatrac R-System Extrusions are available in 300 series (for 3 3/4" walls) and 400 series (for 4 7/8" walls). Standard finishes are Satin Metallic Bronze, Satin Black, Satin White Baked Enamel, and Clear

More information

SECTION FOLDING GLASS PANEL PARTITIONS

SECTION FOLDING GLASS PANEL PARTITIONS SECTION 10 22 26.35 FOLDING GLASS PANEL PARTITIONS USE THIS SECTION WHEN SPECIFYING OVERHEAD SUPPORTED FOLDING GLASS PANEL PARTITIONS. SECTION INCLUDES OVERHEAD TRACK ASSEMBLY, MOUNTING BRACKETS, MOUNTING

More information

FINISH GROUPS #17 GRP #17 CLEAR

FINISH GROUPS #17 GRP #17 CLEAR EFFECTIVE FEBRUARY 1, 2018 CONTENTS A3/1 CONTENTS SECTION A3...DOOR CLOSERS PAGE SURFACE MOUNTED CLOSERS... A3/2 A3/3 CALIBRE TM CLOSERS... A3/4 INTERNATIONAL CONCEALED CLOSERS... A3/5 CONCEALED CLOSER

More information

Series 6000 THERMAL MULTI-PLANE INSTALLATION AND GLAZING MANUAL

Series 6000 THERMAL MULTI-PLANE INSTALLATION AND GLAZING MANUAL Series 6000 THERMAL MULTI-PLANE INSTALLATION AND GLAZING MANUAL Note: Installation and Glazing Manuals are product specific. FOR REVIEW ONLY! TABLE OF ONTENTS General Information... p.2 Frame Fabrication...

More information

NARROW, MEDIUM AND WIDE STILE, THERMASTILE AND DURASTILE. Installation Instructions

NARROW, MEDIUM AND WIDE STILE, THERMASTILE AND DURASTILE. Installation Instructions NARROW, MEDIUM AND WIDE STILE, THERMASTILE AND DURASTILE Installation Instructions PART Y015 JUNE 2016 Table of Contents Section 1. GENERAL NOTES AND GUIDELINES... 2. DOOR HARDWARE A. Locks B. Push/Pulls

More information

Note: Installation and Glazing Manuals are product specific. FOR REVIEW ONLY! OCTOBER Phone: OLDCASTLE ( ) Web Address:

Note: Installation and Glazing Manuals are product specific. FOR REVIEW ONLY! OCTOBER Phone: OLDCASTLE ( ) Web Address: Note: Installation and Glazing Manuals are product specific. FOR REVIEW ONLY! TABLE OF CONTENTS General Information............................. Page 2 4 Outside Glaze Non Thermal...............................Page

More information

350/500 IR Entrances. Features

350/500 IR Entrances. Features OCTOBER, 05 Features FEATURES Blast Mitigation Product 50 IR medium stile has vertical stiles, top and 6-/" (65.) bottom rails 500 IR wide stile has (7) vertical stile, (7) top and 6-/" (65.) bottom rail.

More information

350/500 IR Entrances. Features

350/500 IR Entrances. Features SEPTEMBER, 07 Features FEATURES Blast Mitigation Product 50 IR medium stile has vertical stiles, top and 6-/" (65.) bottom rails 500 IR wide stile has (7) vertical stile, (7) top and 6-/" (65.) bottom

More information

SECTION A4...IMPACT RATED ENTRANCES* 350 IR/500 IR ENTRANCES ENTRANCE HARDWARE OFFERINGS... A4/5

SECTION A4...IMPACT RATED ENTRANCES* 350 IR/500 IR ENTRANCES ENTRANCE HARDWARE OFFERINGS... A4/5 CONTENTS SECTION A4...IMPACT RATED ENTRANCES* Impact Rated Entrances CONTENTS PAGE FINISH GROUPS... A4/3 350 IR/500 IR ENTRANCES ENTRANCE HARDWARE OFFERINGS... A4/5 A4/1 350 IR/500 IR BASE DOOR DOOR CHASSIS...

More information

IF THE END REACTION IS 350# TO 750# THE FOLLOWING PERIMETER ANCHORING CAN BE USED. HEAD AND SILL CONDITIONS WITH EXPOSED INTERIORS SHIMS

IF THE END REACTION IS 350# TO 750# THE FOLLOWING PERIMETER ANCHORING CAN BE USED. HEAD AND SILL CONDITIONS WITH EXPOSED INTERIORS SHIMS 162-960 1 OF 5 USE THESE INSTRUCTIONS IN CONJUNCTION WITH INSTALLATION INSTRUCTIONS 162-970. PERIMETER ANCHORING TO CALCULATE END REACTIONS MODULE(FT) X LENGTH(FT) X WIND LOAD(PSF) A IF THE END REACTION

More information

Installation Instructions

Installation Instructions Installation Instructions 400 Series Curtainwall 3056 WALKER RIDGE DR. NW, SUITE G WALKER, MI 49544 800-866-2227 dependable@tubeliteinc.com Revised September 2014 dependable@tubeliteinc.com Page 1 TABLE

More information

Series 7600 Installation Instructions Aluminum Multi-Slide Door (Pocketing)

Series 7600 Installation Instructions Aluminum Multi-Slide Door (Pocketing) Series 7600 Installation Instructions Aluminum Multi-Slide Door (Pocketing) Things to Know Before You Start Things to Know Before You Start Removal of Old Fenestration Products Ensure any old fenestration

More information

MANUFACTURING INC. Specifications

MANUFACTURING INC. Specifications Page 1 of 4 GENERAL 11 Aluminum security screen doors must be tested by a recognized testing laboratory to conform to SMA 6001-2002 Proposed American National Standard Specifications for Metal Protection

More information

Series 955 Tech Set storefront. Installation Instructions

Series 955 Tech Set storefront. Installation Instructions Series 955 Tech Set storefront Installation Instructions Part NO. Y008 February 2013 TABLE OF CONTENTS SECTION PAGE I II III GENERAL NOTES AND GUIDELINES 1-2 PARTS IDENTIFICATION 3-5 DRILL JIGS 6-7 DRILL

More information

Series Advanced and alternate. Installation Instructions

Series Advanced and alternate. Installation Instructions Series 5500 Advanced and alternate Installation Instructions Part NO. Y557 February 2013 TABLE OF CONTENTS SECTION S-5500 ADVANCED INSTALLATION INSTUCTIONS PAGE I. General Notes and Guidelines...... 3-4

More information

BuildingEnvelope Oldcastle ( ) -

BuildingEnvelope Oldcastle ( ) - BuildingEnvelope 1-866-Oldcastle (653-2278) - www.obe.com RELIANCE -LT CURTAIN WALL 2" X 7-1/2" / POLYAMIDE PRESSURE PLATE / 1" GLAZING Elev-Reliance-LT-750-PolyPP H0042-Steel-Anchor H5021-ShrBlk-Anchors

More information

PIVOT DOOR 3400P INSTALLATION INSTRUCTIONS

PIVOT DOOR 3400P INSTALLATION INSTRUCTIONS Table of Contents I. Tools, Sealant Requirements, Anchor Recommended Table...1 II. Opening, Frame & Panel Verification...2-3 III. Frame Assembly...4 IV. Frame Installation...5-7 V. Glazing Instructions...8

More information

.1 Comply with the General Conditions of the Contract, Supplementary General Conditions and the requirements of Division 1.

.1 Comply with the General Conditions of the Contract, Supplementary General Conditions and the requirements of Division 1. PAGE 1 PART 1 GENERAL 1.1 REFERENCE.1 Comply with the General Conditions of the Contract, Supplementary General Conditions and the requirements of Division 1. 1.2 RELATED WORK SPECIFIED ELSEWHERE.1 Installation

More information

Series Exterior glazed curtain wall. Installation Instructions

Series Exterior glazed curtain wall. Installation Instructions Series 5500 Exterior glazed curtain wall Installation Instructions Part NO. Y550 November 2016 TABLE OF CONTENTS SECTION S-5500 SCREW SPLINE CURTAIN WALL PAGE I. General Notes and Guidelines.. 3-4 II.

More information

GLASSvent TM Windows for Storefront Framing

GLASSvent TM Windows for Storefront Framing MARCH, 05 GLASSvent TM Windows for Storefront Framing INDEX PROJECT-OUT WINDOW... 3-8 OUTSWING CASEMENT WINDOW... 9-4 LAWS AND BUILDING AND SAFETY CODES GOVERNING THE DESIGN AND USE OF GLAZED ENTRANCE,

More information

CURTAIN WALL INSTALLATION AND GLAZING MANUAL

CURTAIN WALL INSTALLATION AND GLAZING MANUAL RELIANCE tm - TC IG CURTAIN WALL INSTALLATION AND GLAZING MANUAL TABLE OF CONTENTS General Information...Page 3-5 Product Use... Page 3 Protection and Storage... Page 3 Check Material... Page 4 Field Conditions...