INSTALLATION INSTRUCTIONS. EnCORE CAPTURED & SSG SCREW SPLINE SHEAR BLOCK TYPE B. EnCORE FEBRUARY, 2012 EC PART NO.

Size: px
Start display at page:

Download "INSTALLATION INSTRUCTIONS. EnCORE CAPTURED & SSG SCREW SPLINE SHEAR BLOCK TYPE B. EnCORE FEBRUARY, 2012 EC PART NO."

Transcription

1 FEBRUARY, INSTALLATION CAPTURED & SSG SCREW SPLINE SHEAR BLOCK TYPE B INSTRUCTIONS

2 2 FEBRUARY, 2012 INSTALLATION INSTRUCTIONS CONTENTS These instructions show the general installation sequence and procedure for typical installations. They supplement the shop details and notations on installation and glazing. SECTION PAGE I 3-4 GENERAL NOTES - MATERIAL HANDLING, STORING & PROTECTION OF ALUMINUM - GENERAL INSTALLATION NOTES - SILICONE GLAZING NOTE - TOOLS REQUIRED II 5-10 PARTS IDENTIFICATION III GENERAL INSTALLATION NOTES IV FRAME FABRICATION, ASSEMBLY & ERECTION V 31 GLAZING ADAPTATION VI INSTALLATION VII GLAZING VIII ENTRANCE FRAMING IX DEGLAZING X 51, 53 DRILL JIGS

3 FEBRUARY, 2012 SECTION I - GENERAL NOTES HANDLING, STORING, AND PROTECTION OF ALUMINUM The material must be protected against damage. The following precautions are recommended to assure early acceptance of your products and workmanship. A. HANDLE CAREFULLY - Don t drop from the truck. Stack with adequate separation so material will not rub together. Store off ground. Protect against elements and other construction trades. Wear hand protection to prevent injury due to sharp edges of cut extrusions. B. KEEP MATERIAL AWAY FROM WATER, MUD AND SPRAY - Prevent cement, plaster, or other materials from damaging the finish. C. PROTECT THE MATERIALS AFTER ERECTION - Protect by wrapping with Kraft paper or by erecting Visqueen or canvas splatter screen. Cement, plaster, terrazzo, other alkaline solutions and acid based materials used to clean masonry are very harmful to the finish and should be removed with water and mild soap IMMEDIATELY. GENERAL INSTALLATION INSTRUCTIONS The following practices are recommended for all installations: A. CHECK SHOP DRAWINGS, INSTALLATION INSTRUCTIONS and GLAZING INSTRUCTIONS to become thoroughly familiar with the project. The SHOP DRAWINGS take precedence and include specific details for the project. The INSTALLATION INSTRUCTIONS are of a general nature and cover most common conditions. B. All materials are to be INSTALLED PLUMB, LEVEL, AND TRUE. C. All work should start from bench marks and/or column lines as established by the ARCHITECTURAL DRAWINGS and the GENERAL CONTRACTOR. Check mullion spacing from both ends of masonry opening to prevent dimensional build-up of day light opening. D. Make certain that construction which will receive your materials is in accordance with the contract documents. If not, notify the GENERAL CONTRACTOR IN WRITING and resolve differences before proceeding with your work. E. Isolate all aluminum to be placed directly in contact with uncured masonry or incompatible materials with a heavy coat of zinc chromate or bituminous paint. F. Check all materials on arrival for quantity and be sure you have everything required to begin installation. G. Sealants must be compatible with all materials with which they have contact, including other sealant surfaces. Consult with sealant manufacturer for recommendations relative to joint size, shelf life, compatibility, priming, tooling, adhesion, etc. H. FASTENING - Fastening means any method of securing one part to another or to adjacent materials. These instructions specify only those fasteners used within the system. Due to varying perimeter conditions and job performance requirements, anchor fasteners are not specified in these instructions. For anchor fastening, refer to the Shop Drawings or consult the fastener supplier. I. CHECK OPENINGS - Make certain that the opening which will receive your materials is in accordance with the contract documents. If not, notify the General Contractor in writing and resolve differences before proceeding with your work. J. BUILDING CODES - Glass and glazing codes governing the design and use of products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility for these design considerations. It is the responsibility of the owner, specifier, architect, general contractor and the installer to make these selections in strict conformance with all applicable codes. K. EXPANSION JOINTS - Expansion joints and perimeter seals shown in these instructions and in the shop drawings are shown at normal size. Actual dimensions may vary due to perimeter conditions and/ or difference in metal temperature between the time of fabrication and time of installation. For example, a 12 foot unrestrained length of aluminum extrusion can expand or contract 3/32 over a 50 F temperature change. Any movement potential should be accounted for at the time of installation. 3

4 4 FEBRUARY, 2012 SECTION I - GENERAL NOTES L. FIELD TESTING - It is recommended that a Water Hose Test be conducted once a sufficient portion of the framing is installed, glazed and caulked to ensure proper installation. The Water Hose test shall be conducted in accordance with AAMA In addition, larger projects should have periodic Water Hose Tests as additional precautionary measures. M. GASKET INVENTORY ROTATION - These high quality rubber extrusions are coated with silicone lubricant. Silicone will dry over time leaving a white chalky residue. Please rotate your stock FIRST IN - FIRST OUT. If the rubber becomes dry, you may use water ONE TIME to reconstitute the silicone, after that, use a soap water solution. TOOLS REQUIRED FOR INSTALLATION CLIP INSTALLATION TOOL (# ) TAPE MEASURE LEVEL DRILL DRILL BITS - #16 (.177), #26 (.147), 1/4" & 5/16" PHILLIPS HEAD SCREW DRIVER CAULK GUN UTILITY KNIFE RUBBER MALLET TAPE - FOR SSG SILICONE SIDE CUTTERS/SNIPS WEATHERING REMOVAL TOOL

5 FEBRUARY, 2012 I LLUSTRATION PART NO. SECTION II - PARTS IDENTIFICATION DESCRIPTION I LLUSTRATION PART NO. DESCRIPTION /16" PERIMETER 1" INFILL /2" MULLION 1" INFILL /16" PERIMETER 1" INFILL 4-/12" PERIMETER 1" INFILL 4-/12" PERIMETER 1" INFILL 6" PERIMETER 1" INFILL 3-9/16" PERIMETER 1/4" INFILL 4-1/2" PERIMETER 1/4" INFILL 6" PERIMETER 1/4" INFILL " MULLION 1" INFILL 3-9/16" MULLION 1/4" INFILL 4-1/2" MULLION 1/4" INFILL 6" MULLION 1/4" INFILL 3-9/16" HEAVY MULLION 1" INFILL 4-1/2" HEAVY MULLION 1" INFILL 6" HEAVY MULLION 1" INFILL /16" NARROW 1-1/4" PERIMETER - 1" INFILL /16" SPLIT MULLION 1" INFILL /2" NARROW 1-1/4" PERIMETER - 1" INFILL /2" SPLIT MULLION 1" INFILL " NARROW 1-1/4" PERIMETER - 1" INFILL 3-9/16" NARROW 1-1/4" PERIMETER - 1/4" INFILL 4-1/2" NARROW 1-1/4" PERIMETER - 1/4" INFILL 6" NARROW 1-1/4" PERIMETER - 1/4" INFILL STANDARD COVER DEEP COVER STANDARD COVER FOR NARROW 1-1/4" PERIMETER DEEP COVER FOR NARROW 1-1/4" PERIMETER " SPLIT MULLION 1" INFILL 3-9/16" SPLIT MULLION 1/4" INFILL 4-1/2" SPLIT MULLION 1/4" INFILL 6" SPLIT MULLION 1/4" INFILL 3-9/16" HEAVY SPLIT MULLION - 1" INFILL 4-1/2" HEAVY SPLIT MULLION - 1" INFILL 6" HEAVY SPLIT MULLION - 1" INFILL SPLIT MULLION FILLER FOR / /16" MULLION 1" INFILL SPLIT MULLION FILLER FOR /056

6 6 FEBRUARY, 2012 I LLUSTRATION PART NO. SECTION II - PARTS IDENTIFICATION DESCRIPTION I LLUSTRATION PART NO. DESCRIPTION SPLIT MULLION FILLER FOR / /16" CORNER HALF 1/4" INFILL SPLIT MULLION FILLER FOR SPLIT MULLION FILLER FOR SPLIT MULLION FILLER FOR /16" SSG MULLION 1" INFILL 4-1/2" SSG MULLION 1" INFILL 6" SSG MULLION 1" INFILL 3-9/16" SSG MULLION 1/4" INFILL /2" CORNER HALF 1/4" INFILL 6" CORNER HALF 1/4" INFILL 4-1/2" O/P, B/H DOOR JAMB (FRONT GLAZE) W/ GASKET 4-1/2" O/P, B/H DOOR JAMB (CENTER GLAZE) W/ GASKET /2" SSG MULLION 1/4" INFILL /2" C/H DOOR JAMB (FRONT GLAZE) " SSG MULLION 1/4" INFILL FLASHING FOR 3-9/16" STANDARD PERIMETER FLASHING FOR 4-1/2" STANDARD PERIMETER FLASHING FOR 6" STANDARD PERIMETER FLASHING FOR 3-9/16" NARROW 1-1/4" PERIMETER FLASHING FOR 4-1/2" NARROW 1-1/4" PERIMETER FLASHING FOR 6" NARROW 1-1/4" PERIMETER 3-9/16" CORNER HALF 1" INFILL 4-1/2" CORNER HALF 1" INFILL /2" C/H DOOR JAMB (CENTER GLAZE) 4-1/2" O/P, B/H COMMON DOOR JAMB W/ GASKET SSG 4-1/2" DOOR JAMB (FRONT GLAZED) 1/4" INFILL SSG 6" DOOR JAMB (FRONT GLAZED) 1/4" INFILL 6" O/P, B/H DOOR JAMB ADAPTER W/ GASKET " CORNER HALF 1" INFILL " CENTER HUNG DOOR JAMB ADAPTER

7 FEBRUARY, 2012 I LLUSTRATION PART NO. SECTION II - PARTS IDENTIFICATION DESCRIPTION I LLUSTRATION PART NO. DESCRIPTION " O/P, B/H COMMON DOOR JAMB ADAPTER W/ GASKET ALUMINUM SNAP-IN FLAT FILLER " C/H COMMON DOOR JAMB ADAPTER 4-1/2" or 6" SSG DOOR JAMB ADAPTER 4-1/2" or 6" COMMON SSG DOOR JAMB ADAPTER 4-1/2" O/P, B/H HEADER or T-BAR 4-1/2" SAM-II/SA-INT HEADER or T-BAR 4-1/2" HUSKY II/INTERNATIONAL HEADER or T-BAR 6" O/P, B/H HEADER or T-BAR W/ GASKET END LOAD CLIP PACKAGE SETTING BLOCK CHAIR PACKAGE - 1" INFILL SETTING BLOCK CHAIR PACKAGE - 1/4" INFILL SETTING BLOCK CHAIR PACKAGE 1-1/4" PERIMETER - 1" INFILL SETTING BLOCK CHAIR PACKAGE 1-1/4" PERIMETER - 1/4" INFILL TRANSOM GLASS STOP (FRONT GLAZED) TRANSOM GLASS STOP (CENTER GLAZED) " SAM-II/SA-INT HEADER or T-BAR GLAZING ADAPTER FOR TRANSOM JAMB " HUSKY II/INTERNATIONAL HEADER or T-BAR SMALL SHEAR BLOCK PACKAGE FOR 3-9/16" SYSTEM O/P, B/H HEADER or TRAY T-BAR C/H HEADER or T-BAR TRAY W/ WEATHERING /4" INFILL ADAPTER /2" INFILL ADAPTER /4" INFILL ADAPTER SSG 1/2" INFILL ADAPTER WINDOW ADAPTER LARGE SHEAR BLOCK PACKAGE FOR 4-1/2" & 6" SYSTEM SMALL SHEAR BLOCK PKG. 1-1/4" PERIMETER FOR 3-9/16" SYSTEM LARGE SHEAR BLOCK PKG. 1-1/4" PERIMETER FOR 4-1/2" & 6" SYSTEM " THERMAL HEAD RECEPTOR W/ GASKET P.V.C. FLAT FILLER

8 A 1 A B 2 B C 3 C A A SMALL PERIMETERS SMALL MULLIONS AND CORNERS INTERMEDIATE AND LARGE PERIMETERS MEDIUM AND LARGE MULLIONS &CORNERS SMALL SHEAR BLOCK B C LARGE SHEAR BLOCK B 11/4" HEAD 1 1/4" SHEAR BLOCK 1 1/4" SCREW SPLINE 1 1/4" SHEAR BLOCK 11/4" SILL C C A A 8 FEBRUARY, 2012 I LLUSTRATION PART NO. SECTION II - PARTS IDENTIFICATION DESCRIPTION I LLUSTRATION PART NO. DESCRIPTION DOUBLE ACTING TRANSOM BAR CLIP PACKAGE HEAVY FIXED GASKET SINGLE ACTING R.H. TRANSOM BAR CLIP PACKAGE SINGLE ACTING L.H. TRANSOM BAR CLIP PACKAGE C/H INTERNATIONAL CLOSER T-BAR CLIP PACKAGE O/P INTERNATIONAL CLOSER T-BAR CLIP PACKAGE B/H INTERNATIONAL CLOSER T-BAR CLIP PACKAGE SSG TEMPORARY GLAZING CLIP WATER DEFLECTOR (1" SYSTEM ONLY) SSG GASKET PERIMETER GASKET FOR 1-3/4" PERIMETER OR 1-1/4" COVER GASKET FOR CORNER FLASHING TRANSOM "W" BLOCK STYROFOAM PERIMETER FILLER SETTING BLOCK FOR LIGHT HORIZONTAL SETTING BLOCK FOR HEAVY HORIZONTAL SCREW #10 x 1-19/32" PHTFS FOR SHEAR BLOCKS SETTING BLOCK FOR TRANSOM BAR HORIZONTAL ATTACHMENT SCREW #10 x 19/16" FHTFS HOLE PLUG B B SSG SYSTEM SPLINE SCREW #8 x 1-1/4" PHTFS SSG ADAPTER SCREW #8 x 1-1/4" FTHFS END LOAD CLIP SCREW #10 x 11/16" PHTFS DOOR HEADER ATTACHMENT SCREW #12 x 1/2" FHTFS DRILL JIG FOR SCREW SPLINE AND SHEAR BLOCK ASSEMBLY DRILL JIG FOR SCREW SPLINE AND SHEAR BLOCK ASSEMBLY WITH 1-1/4" PERIMETER DRILL JIG FOR SSG SHEAR BLOCK ASSEMBLY X PANDR SPLICE SLEEVE END DAM FOR 3-9/16" SYSTEM (TYPE "A" ) END DAM FOR 4-1/2" SYSTEM (TYPE "A" ) END DAM FOR 6" SYSTEM (TYPE "A") END DAM PACKAGE FOR (TYPE "B") PERIMETER WITH 1/4" & 1" INFILL GLAZING CLIP TEMPORARY GLAZING CLIP LIGHT FIXED GASKET GLAZING CLIP INSTALLATION TOOL STANDARD FIXED GASKET

9 FEBRUARY, 2012 I LLUSTRATION PART NO. SECTION II - PARTS IDENTIFICATION DESCRIPTION I LLUSTRATION PART NO. DESCRIPTION PERIMETER FILLER FOR / PERIMETER FILLER FOR /031 PERIMETER FILLER FOR /061 PERIMETER FILLER FOR /081 PERIMETER FILLER FOR /111 PERIMETER FILLER FOR /131 OPTIONAL MULLION CAP

10 10 FEBRUARY, 2012 SECTION II - PARTS IDENTIFICATION SETTING BLOCK SELECTION CHAR T FOR 3/8" GLASS BITE FRAME EXTRUSION SETTING BLOCK NOTES REFERENCE , 003, 005 & , 023, 025 & , 053, 055 & , 073, 075 & , 103, 105 & , 123, 125 & , 004 & , 054 & , 104 & & & & /16" x 1-3/8" 4-1/8" Long /8" x 1-3/8" 4-1/8" Long /8" x 1-3/8" 4-1/8" Long /16" x 1-3/8" 4-1/8" Long TEAR SETTING BLOCKS IN HALF FOR 1/4" SYSTEM AND ADAPTED SYSTEMS TEAR SETTING BLOCKS IN HALF FOR 1/4" SYSTEM AND ADAPTED SYSTEMS TEAR SETTING BLOCKS IN HALF FOR 1/4" SYSTEM AND ADAPTED SYSTEMS 3/8" 3/8" 3/8" 11/16"

11 FEBRUARY, SECTION III - GENERAL INSTALLATION NOTES Depending on actual job conditions and the particular depth system being installed, there are three (3) possible methods of assembling the EnCORE Framing System. Although all three (3) methods of assembly will be covered individually the following notes apply to all systems. SCREW SPLINE FABRICATION (See Page 14) For continuous STRIP windows. Unlimited Max.Width SHEAR BLOCK FABRICATION (See Page 15) For PUNCHED opening windows OR continuous STRIP windows Unlimited Max.Width TYPE B FABRICATION (See Page 23 ) For PUNCHED opening windows OR continuous STRIP windows, with splice joints. 24' Max. Unspliced Unit Unlimited Spliced Units NOTE A: After selecting the appropriate depth system and method of assembly, predetermine which perimeter members run through and which ones butt, to expedite fabrication and assembly. NOTE B: Regardless of the particular method of assembly, the vertical covers should always run through and the horizontal covers butt between. NOTE C: Sill flashing for SCREW SPLINE & SHEAR BLOCK FABRICATION should be placed directly under the sill member. Any shimming that is required should be placed under the sill flashing. Sill flashing should extend the full opening dimension minus 1/4" and be set in a heavy bead of sealant. Seal flashing against end dams and all sill attachment points. NOTE D: Allow a minimum of 1/4" clearance at the head and both jambs to facilitate installation and provide room for caulking. If job conditions are uncertain or masonry openings are irregular, allow extra clearance to accommodate construction tolerances. NOTE: Horizontal covers should be cut 1/16"short to allow for expansion. Splice D.L.O. C/L

12 12 FEBRUARY, 2012 SECTION III - GENERAL INSTALLATION NOTES NOTE E: Perimeter weather seals should be run after the gutter framing members are installed and "BEFORE" the covers are applied. Cosmetic seals may be run after the covers are applied at the head and jambs "ONLY". Sill covers must remain open to allow water drainage to the exterior. FLAT FILLER (TYP.) REQUIRED STYROFOAM FILLER OPTIONAL (OPTIONAL) OPTIONAL OPTIONAL WEEP AREA REQUIRED TYP. GUTTER OPTIONAL OPTIONAL NOTE F: All systems are available for 1/4" and 1" infills. The 1" systems will accommodate other size infills by using snap-in adapters, optional weathering or a combination of both. NOTE G: Clip spacing of each elevation must be checked to meet windload requirements. Glazing clips should be located 3" from each end of member and subsequently spaced per formula below. STEP #1: Locate the largest lite of glass on each ELEVATION. STEP #2: Determine the width and height for the largest glass lite. STEP #3: Use the smallest of the two dimensions for the MODULE (FT.) spacing. STEP #4: Match that Module (ft.) spacing with the required windload on the chart below. WINDLOAD (P.S.F.) NOTE H: Glass Size Formula for Captured Systems A B 4 5 F 6 E 7 D C 8 MODULE (FT) = (D.L.O.+ 3/4") A = 6" O.C. B = 7" O.C. C = 8" O.C. D = 9" O.C. E = 10" O.C. F = 12" O.C. 5'-3-1/2" 3'-0" W X Y Y Y Y SAMPLE ELEVATION REQUIRED SAMPLE CALCULATION Lite "W" 3'-0" x 5'-3-1/2" 3'-0" 12" O.C. for 25 P.S.F. 10" O.C. for 35 P.S.F. Glass Size Formula for SSG System (Vertical = D.L.O.+ 3/4") (Horizontal = D.L.O. Between Mullions + 1-1/8") (Horizontal = D.L.O. Between Jamb and Mullion + 15/16")

13 FEBRUARY, 2012 SECTION IV - FRAME FABRICATION, ASSEMBLY & ERECTION SCREW SPLINE FABRICATION & SHEAR BLOCK FABRICATION. These methods of assembly allow the vertical mullions to run through the head and sill perimeters. 13 The Screw Spline method of assembly utilizes a two piece mullion which allows individual bays to be pre-assembled and snapped together during erection to form continuous strip windows. All framing intersections are assembled using screw spline joinery - no shear blocks. The Shear Block method of assembly utilizes a tubular mullion with applied shear blocks. Due to vertical mullions running through the sill perimeter, continuous flashing must be used. NOTE: Cut all framing members to required formulas as shown below. TYPE B FABRICATION FORMULAS FOR SYSTEMS WITH 1-3/4" & 1-1/4" PERIMETERS HEAD, SILL & INTERMEDIATE HORIZONTAL = DAY LIGHT OPENING WIDTH MULLIONS & JAMBS = FRAME HEIGHT This method of assembly allows prefabricated frames to be installed as a unit into punched openings. Head and sill perimeter extrusions run through and verticals run between. Verticals are attached to the head and sill by screw spline joinery. Shear block joinery is used at intermediate horizontals. NOTE: Cut all framing members to required formulas as shown below. FORMULAS FOR SYSTEMS WITH 1-3/4" PERIMETERS HEAD AND SILL = FRAME WIDTH MULLIONS & JAMBS = FRAME HEIGHT - 3-1/2" INTERMEDIATE HORIZONTALS = DAY LIGHT OPENING WIDTH FORMULAS FOR SYSTEMS WITH 1-1/4" PERIMETERS HEAD AND SILL = FRAME WIDTH MULLIONS & JAMBS = FRAME HEIGHT - 2-1/2" INTERMEDIATE HORIZONTALS = DAY LIGHT OPENING WIDTH SNAP ON COVERS Regardless of the method of assembly, the vertical covers should always run through and the horizontal covers butt between. The only exception to this is with the SSG mullion, which has no vertical cover, therefore the horizontal covers span the mullions and butt between the jamb covers. NOTE: Cut all covers to required formulas as shown below. COVER FORMULAS FOR SCREW SPLINE & SHEAR BLOCK FABRICATION STANDARD & *SSG = MULLIONS & JAMB COVERS = FRAME HEIGHT STANDARD (non-ssg) = HEAD, SILL & INTERMEDIATE HORIZONTAL COVERS = D.L.O. MINUS 1/16" *SSG W/ 1-3/4" JAMBS FOR HEAD & INTERMEDIATE HORIZ. COVERS = D.L.O.'S + MULLION WIDTHS + 9/16" AT EACH SPLICE *SSG W/ 1-1/4" JAMBS FOR HEAD & INTERMEDIATE HORIZ. COVERS = D.L.O.'S + MULLION WIDTHS + 9/16" AT EACH SPLICE *SSG SILL COVERS = D.L.O.'S + 9/16" AT EACH VERTICAL FOR WEEP COVER FORMULAS FOR TYPE B FABRICATION STANDARD & *SSG MULLIONS & JAMB COVERS = FRAME HEIGHT MINUS 1/8" STANDARD (NON-SSG) HEAD, SILL & INTERMEDIATE HORIZONTAL COVERS = D.L.O. MINUS 1/16" *SSG W/ 1-3/4" JAMBS FOR HEAD & INTERMEDIATE HORIZ. COVERS = D.L.O.'S + MULLION WIDTHS + 9/16" AT EACH SPLICE *SSG W/ 1-1/4" JAMBS FOR HEAD & INTERMEDIATE HORIZ. COVERS = D.L.O.'S + MULLION WIDTHS + 9/16" AT EACH SPLICE *SSG SILL COVERS = D.L.O.'S + 9/16" AT EACH VERTICAL FOR WEEP *SSG horizontal covers to be spliced at every second (2nd) vertical mullion, not to exceed 12'-0". If SSG sill covers can not be drilled for weeps, then SSG sill covers are spliced at each vertical. SSG systems do not have vertical mullion covers. GLAZING ADAPTERS = CUT TO D.L.O.

14 14 FEBRUARY, 2012 SECTION IV - FRAME FABRICATION, ASSEMBLY & ERECTION FRAME ASSEMBLY - STANDARD FRAMES SCREW SPLINE FABRICATION - (JOINT SEAL METHOD SHOWN) SPLIT MULLION FLAT FILLER HEAD SPLINE SCREWS WATER DEFLECTOR SPLINE SCREWS SETTING BLOCK CHAIR GLAZING CLIP INTERMEDIATE HORIZONTAL SILL COVER SILL FLASHING

15 FEBRUARY, SECTION IV - FRAME FABRICATION, ASSEMBLY & ERECTION FRAME ASSEMBLY - STANDARD FRAMES SHEAR BLOCK FABRICATION - (JOINT SEAL METHOD SHOWN) MULLION (Standard Mullion Shown SSG Optional) HEAD SHEAR BLOCK WATER DEFLECTOR COVER SETTING BLOCK CHAIR INTERMEDIATE HORIZONTAL GLAZING CLIP SILL SILL FLASHING

16 16 FEBRUARY, 2012 SECTION IV - FRAME FABRICATION, ASSEMBLY & ERECTION SCREW SPLINE FABRICATION JOINERY PREPARATION NOTE 1: Placing a screw in the first hole drilled will help to hold drill jig in alignment. NOTE 2: Use locating pins on end of jig that displays part number. (for all extrusions except Split Mullion Fillers & SSG mullions). SSG mullions utilize a separate jig NOTE: THICK END IS ALWAYS THE EXTERIOR SIDE Standard Jig (Rotate as shown for split mullion fillers) SSG Jig NOTE 3: Align jig, with locating pins against the glazing reglet, slide the drill fixture into position as shown: Drill screw spline clearance holes with #16 (.177) bit at points marked (1 & 2) or (1 & 3), as noted on Jig. For 1-3/4" Head or Sill: Align jig flush with ends of perimeter. For Intermediate Horizontal: Align jig with horizontal location marks. For 1-1/4" Head or Sill: Align holes with the ends of perimeter /4" Perimeter Jig

17 FEBRUARY, SECTION IV - FRAME FABRICATION, ASSEMBLY & ERECTION SHEAR BLOCK FABRICATION JOINERY PREPARATION NOTE 1: Placing a screw in the first hole drilled will help to hold drill jig in alignment.. NOTE 2: Use locating pins on end of jig that displays part number (for all extrusions except SSG mullions). SSG mullions utilize a separate jig as shown below Standard Jig SSG Jig NOTE 3: Align jig, with locating pins against the glazing reglet, slide the drill fixture into position as noted: Drill shear block mounting holes with #26 (.147) bit at points marked (A & B) or (A, B & C), as noted on jig. For 1-3/4" Head* or Sill: Align jig flush with ends of perimeter. *NOTE: Flip jig to prep for shear block at head. Head prep is the same as an upside down sill or intermediate horizontal prep. For Intermediate Horizontal: Align jig with horizontal location marks. For 1-3/4" & 1-1/4" perimeters. For 1-1/4" Head or Sill: Align holes with the ends of perimeter /4" Perimeter Jig

18 18 FEBRUARY, 2012 SECTION IV - FRAME FABRICATION, ASSEMBLY & ERECTION SCREW SPLINE & SHEAR BLOCK FABRICATION PERIMETER ANCHOR CLEARANCE HOLES (Screw Spline & Shear Block Assembly) Pre-drill perimeter anchor clearance holes according to required fastener size. Locate perimeter anchors within 6" of mullions, jambs, horizontals and 24" on center unless specified otherwise. C L INTERMEDIATE HORIZONTAL FASTENING (Shear Block Assembly Only) Using a 1/4" bit, pre-drill clearance holes in horizontal "V" groove for mounting the horizontal to the vertical mullion. This hole should be on the top and 1/2" from each end of the horizontal. 1/2" 1/4" Clearance Hole at location groove. 24" C L 6" C L 24" C L 6"

19 FEBRUARY, SECTION IV - FRAME FABRICATION, ASSEMBLY & ERECTION SCREW SPLINE & SHEAR BLOCK FABRICATION SEAL METHODS FOR BOTH VERTICAL AND HORIZONTAL JOINERY SCREW SPLINE (Joint Seal Method) Attach horizontal with (#8 x 1-1/4" R.H.T.F.S.) on each vertical mullion. Inspect and remove any burrs found on the front edge of horizontal. Joint seals are similar for head and sill. SHEAR BLOCKS (Joint Seal Method) Attach horizontal shear blocks with (#10 x 1-19/32" R.H.T.F.S.) on each vertical mullion. Inspect and remove any burrs found on the front edge of all shear blocks. Joint seals at head and sill similar for all shear blocks. NOTE: APPLY SEALANT TO TOP, BOTTOM AND FRONT OF SHEAR BLOCKS. STANDARD FOR THE SSG SYSTEM. OPTIONAL QUICKSEAL METHOD SHEAR BLOCKS (QUICKSEAL Method) Attach horizontal shear blocks with (#10 x 1-19/32" R.H.T.F.S.) on each vertical mullion. Inspect and remove any burrs found on the front edge of all shear blocks. Burrs may hold the intermediate horizontal back from seating completly with vertical mullions. NOTE: APPLY SEALANT TO TOP, BOTTOM AND FRONT OF SHEAR BLOCKS. STANDARD FOR THE SSG SYSTEM.

20 20 FEBRUARY, 2012 SECTION IV - FRAME FABRICATION, ASSEMBLY & ERECTION SCREW SPLINE FABRICATION - OPTIONAL QUICKSEAL METHOD WEATHERING Apply weathering to all mullions and jambs. Weathering must be run long on each end to allow for shrinkage off the roll. Apply perimeter gasket to all head, sill and jambs. Cut to D.L.O. at Head & Sill NOTE: Inspect weathering for any defects and replace if found. HORIZONTAL ASSEMBLY Clamp the horizontals between the verticals before fastening with spline screw # (#8 x 1-1/4" R.H.T.F.S.). Assembly works best if the screws closest to the weathering are run in first. INSPECT: INSPECT THE WEATHERING ON BOTH SIDES OF EXTENDED LEG AS SHOWN. IT SHOULD BE PINCHED SECURELY BETWEEN VERTICAL AND HORIZONTAL FACE. THIS SHOULD BE TESTED BY TRYING TO ROLL IT OUT AT EACH JOINT. REWORK ANY JOINTS FOUND WITH LOOSE WEATHERING.

21 FEBRUARY, SECTION IV - FRAME FABRICATION, ASSEMBLY & ERECTION SHEAR BLOCK FABRICATION - OPTIONAL QUICKSEAL METHOD WEATHERING Apply weathering to all vertical mullions and jambs. Weathering must be run long on each end to allow for shrinkage off the roll. Apply perimeter gasket to head, sill and jambs. HORIZONTAL ASSEMBLY Slide horizontals over shear blocks and offset drill the shear block through the clearance hole side closest to the vertical mullion. Drill a.147 dia. hole through the shear block using a #26 bit. Clamp horizontals between the verticals before fastening with spline screw # (#10 x 9/16" F.H.T.F.S.). INSPECT AND SEAL: INSPECT THE WEATHERING ON BOTH SIDES OF EXTENDED LEG AS SHOWN. IT SHOULD BE PINCHED SECURELY BETWEEN VERTICAL AND HORIZONTAL FACE. THIS SHOULD BE TESTED BY TRYING TO ROLL IT OUT AT EACH JOINT. REWORK ANY JOINTS FOUND WITH LOOSE WEATHERING. SEAL THREADS OF HORIZONTAL ATTACHMENT SCREW AND OVER HEAD AS SHOWN. CUT OFF EXTRA WEATHERING AT BOTH ENDS OF JAMB AND VERTICAL MULLIONS.

22 22 FEBRUARY, 2012 SECTION IV - FRAME FABRICATION, ASSEMBLY & ERECTION SCREW SPLINE & SHEAR BLOCK FABRICATION WEEP AT SILL (1/4" system only) The bottom inch of on the jambs and mullions must be trimmed as shown for both screw spline and shear block systems. This trimming will create a weep channel for the diversion of water. NOTE: DETAIL OF TRIMMED GASKET SKIP TO SECTION V - GLAZING (Pages 23 through 30 are for TYPE B FABRICATION)

23 FEBRUARY, SECTION IV - FRAME FABRICATION, ASSEMBLY & ERECTION FRAME ASSEMBLY - STANDARD FRAMES TYPE B FABRICATION - (OPTIONAL QUICKSEAL METHOD SHOWN) MULLION GLAZING CLIP HEAD SHEAR BLOCK WATER DEFLECTOR COVER SPLINE SCREWS COVER SETTING BLOCK CHAIR GLAZING CLIP INTERMEDIATE HORIZONTAL SILL

24 24 FEBRUARY, 2012 SECTION IV - FRAME FABRICATION, ASSEMBLY & ERECTION FRAME ASSEMBLY - SSG FRAMES TYPE B FABRICATION - OPTIONAL QUICKSEAL METHOD SHOWN) SSG MULLION HEAD SHEAR BLOCK GLAZING CLIP SPLINE SCREWS COVER SETTING BLOCK CHAIR GLAZING CLIP INTERMEDIATE HORIZONTAL SILL

25 FEBRUARY, SECTION IV - FRAME FABRICATION, ASSEMBLY & ERECTION TYPE B FABRICATION JOINERY PREPARATION: NOTE 1: Placing a screw in the first hole drilled will help to hold drill jig in alignment. NOTE 2: Use locating pins on end of jig that displays part number, (for all extrusions except SSG mullions). SSG mullions utilize a separate jig as shown below. 1-3/4" PERIMETER AT HEAD AND SILL With locating pins against the glazing reglet, slide the drill fixture flush with ends of perimeter. Measure and mark the center line dimensions to locate vertical mullions.drill screw spline clearance holes with #16 (.177) bit at points marked (1 & 2) or (1 & 3), as noted on jig INTERMEDIATE SHEAR BLOCK With locating pins against the glazing reglet, slide the drill fixture to align with horizontal location marks. Drill shear block mounting holes with #26 (.147) bit at points marked (A & B) or (A, B & C), as noted on jig Std. Jig 1-1/4" PERIMETER AT HEAD AND SILL With locating pins against the glazing reglet, slide the drill fixture to align with the ends of perimeter. Drill screw spline clearance holes with #16 (.177) bit at points marked (1 & 2) or (1 & 3) Std. Jig /4" Perimeter Jig SSG Jig

26 26 FEBRUARY, 2012 SECTION IV - FRAME FABRICATION, ASSEMBLY & ERECTION TYPE B FABRICATION WEEP SYSTEM AND FASTENER HOLES PERIMETER ANCHORS CLEARANCE HOLES Pre-drill perimeter anchor clearance holes according to required fastener size. Locate perimeter anchors within 6" of mullions, jambs, horizontals and 24" on center unless specified otherwise. C L 24" C L 6" 6" C L 5/16" WEEP HOLES MIN. WEEP SYSTEM Using a 5/16" bit, pre-drill weeps at jamb and mullion center lines. Start in the center of the sill weathering pocket and drill through. INTERMEDIATE HORIZONTAL FASTENING Using a 1/4" bit, pre-drill clearance holes in horizontal "V" groove for mounting the horizontal to the vertical mullion. This hole should be on the top and 1/2" from each end of the horizontal. 1/2" 24" C L 6" C L 6" C L 1/4" CLEARANCE HOLE AT LOCATION GROOVE 24"

27 FEBRUARY, SECTION IV - FRAME FABRICATION, ASSEMBLY & ERECTION TYPE B FABRICATION SEAL METHODS FOR BOTH VERTICAL AND HORIZONTAL JOINERY SHEAR BLOCKS (Joint Seal Method) Attach horizontal shear blocks with (#10 x 1-19/32" R.H.T.F.S.) on each vertical mullion. Inspect and remove any burrs found on the front edge of all shear blocks. Joint seals at head and sill similar for all shear blocks. NOTE: APPLY SEALANT TO TOP, BOTTOM AND FRONT OF SHEAR BLOCKS. STANDARD FOR THE SSG SYSTEM. SCREW SPLINE (Joint Seal Method) Attach horizontal with (#8 x 1-1/4" R.H.T.F.S.) on each vertical mullion. Inspect and remove any burrs found on the front edge of horizontal. Joint seals are similar for head and sill. OPTIONAL QUICKSEAL METHOD SHEAR BLOCKS (QUICKSEAL Method) Attach horizontal shear blocks with (#10 x 1-19/32" R.H.T.F.S.) on each vertical mullion. Inspect and remove any burrs found on the front edge of all shear blocks. Burrs may hold the intermediate horizontal back from seating completely with vertical mullions. NOTE: APPLY SEALANT TO TOP, BOTTOM AND FRONT OF SHEAR BLOCKS. STANDARD FOR THE SSG SYSTEM.

28 28 FEBRUARY, 2012 SECTION IV - FRAME FABRICATION, ASSEMBLY & ERECTION TYPE B FABRICATION - OPTIONAL QUICKSEAL METHOD SHEAR BLOCK ATTACHMENT AND HORIZONTAL ASSEMBLY WEATHERING Apply perimeter gasket at this stage of installation. Apply weathering to ALL mullions and jambs. Weathering must be run long on each end to allow for shrinkage off the roll. NOTE: Inspect weathering for any defects and replace it if found. HORIZONTAL ASSEMBLY Slide horizontals over shear blocks and offset drill the shear block through the clearance hole side closest to the vertical mullion. Drill a.147 dia. hole through the shear block using a #26 bit. Clamp the horizontals between the verticals before fastening with screw # (#10 x 9/16" F.H.T.F.S.). Clamp jambs to horizontals and attach using spline screw # (#8 x 1-1/4" R.H.T.F.S.). This works best if the screws closest to the weathering are run in first. INSPECT AND SEAL INSPECT THE WEATHERING ON BOTH SIDES OF EXTENDED LEG AS SHOWN. IT SHOULD BE PINCHED SECURELY BETWEEN VERTICAL AND HORIZONTAL FACE. THIS SHOULD BE TESTED BY TRYING TO ROLL IT OUT AT EACH JOINT. REWORK ANY JOINTS FOUND WITH LOOSE WEATHERING. SEAL THREADS OF HORIZONTAL ATTACHMENT SCREW AND OVER HEAD OF SCREW AS SHOWN.

29 FEBRUARY, SECTION IV - FRAME FABRICATION, ASSEMBLY & ERECTION TYPE B FABRICATION - OPTIONAL QUICKSEAL METHOD HEAD AND SILL ASSEMBLY Pull weathering back from the ends of all verticals. Attach head and sill to verticals using screw # (#8 X 1-1/4" R.H.T.F.S.). This works best if screws closest to weathering are run in first. Apply perimeter gasket at this stage of installation. Cut to (D.L.O.@ Sill) and to (FRAME Head). WEATHERING & SEALANT After head and sill are assembled cut vertical weathering to be 1/2" long at both head and sill. Compress vertical weathering into pocket as shown below. INSPECT: INSPECT THE WEATHERING ON BOTH SIDES OF VERTICAL MULLIONS AND AT THE JAMBS. IT SHOULD BE PINCHED SECURELY BETWEEN VERTICAL AND HORIZONTAL FACE. THIS SHOULD BE TESTED BY TRYING TO ROLL IT OUT AT EACH JOINT. REWORK ANY JOINTS FOUND WITH LOOSE WEATHERING. APPLY SEALANT TO INSIDE CORNERS OF ALL WEATHERED JOINTS AT SILL ONLY. NOTE: Weathering is cut to D.L.O.at sill to allow for weeping.

30 30 FEBRUARY, 2012 SECTION IV - FRAME FABRICATION, ASSEMBLY & ERECTION TYPE B FABRICATION JAMB ACCESSORIES SILL END DAMS End dams to be located at both ends of sill and head members. Use the end dam as a template, drill two holes through the jambs as shown with #26 (.147) bit. Place sealant over half the end dam so it will seal both the horizontal and vertical ends at the same time. Locate and screw apply with (2) two # (#10 x 9/16" F.H.T.F.S.). END LOAD FORMULAS TYPE B FABRICATION FORMULA FOR 1-1/4" PERIMETER WITHOUT END LOAD CLIPS: If mullion spacing (ft.) times height (ft.) times specified windload (PSF) divided by 2 exceeds 600 pounds change to 1-3/4" perimeter and check end load reaction with new formula. FORMULA FOR 1-3/4" PERIMETER WITHOUT END LOAD CLIPS: If mullion spacing (ft.) times height (ft.) times specified windload (PSF) divided by 2 exceeds 700 pounds add perimeter end load clips and check end load reaction with new formula. FORMULA FOR 1-3/4" PERIMETER WITH END LOAD CLIPS: If mullion spacing (ft.) times height (ft.) times specified windload (PSF) divided by 2 exceeds 1000 pounds consult Area Application Engineering Department. SEALANT END LOAD CLIPS (SPECIAL) When end load clips have been deemed as required for mullions, install clips at mullions as noted below. Drop load the end load clip into head and sill perimeter extrusion after frame assembly. Using the end load clip as a template, locate the two middle screw clearance holes in alignment with the vertical screw spline screws as shown. Drill (6) six holes through the head and sill perimeter extrusion with #28 (.147) bit. Apply the clips using (6) six # (#10 x 11/16" R.H.T.F.) Screws. Seal and tool over all end load clip screws that enter the head and sill perimeter channels. SEALANT

31 FEBRUARY, 2012 SECTION V - GLAZING ADAPTATION ALL SYSTEMS GLAZING ADAPTATIONS 31 GLAZING ADAPTER FOR STANDARD SYSTEMS STEP 1: Cut adapters to D.L.O. STEP 2: Apply sealant in full length of channel adapter. STEP 3: Snap horizontal adapters into glazing reglet of frame. STEP 4: Snap vertical adapters into glazing reglet of frame. STEP 5: Seal and tool ends of adapters together. STEP 6: Apply weathering and seal ends of weathering at corners. GLAZING ADAPTERS FOR SSG SYSTEMS STEP 1: Cut adapters to D.L.O. STEP 2: Drill attachment screw clearance holes in the vertical adapter every foot on center with a #16 (.177) bit. STEP 3: Locate adapter on mullion and match drill with #26 (.147) bit. STEP 4: Screw apply adapter to mullion using (#8 x 1-1/4" F.H.T.F.S.). STEP 5: Follow steps shown above for horizontal adapter, weathering installation and sealing. ADAPTER (#8 x 1-1/4" F.H.T.F.) GASKET SSG ADAPTER INSIDE SEALED SSG ADAPTER OUTSIDE SEALED

32 32 FEBRUARY, 2012 SECTION VI - INSTALLATION SILL FLASHING AND SPLICES - SCREW SPLINE & SHEAR BLOCK FABRICATION SILL FLASHING INSTALLATION Install flashing at the sill. It should be level, shimmed up a minimum of 1/4" and carefully sealed at both ends. The flashing should run the full width of the opening minus (-) 1/4", being interrupted only at entrances. If opening is over 24'-0" wide a splice joint is required every 12'-0". (See splice joint procedure below). SEALANT PIN END DAM TO FLASHING FLASHING END DAM UNDER FLASHING CUT TO FIT MASONRY SPLICE JOINTS - SCREW SPLINE & SHEAR BLOCK FABRICATION SEAL JUST BEFORE INSTALLATION OF UNIT. (CONTINUOUS BEAD OF SEALANT BEHIND ALL FRAMING AT SILL) SPLICES SHOULD BE LOCATED A MAXIMUM OF EVERY 12'-0" WITH A 1/2" JOINT BETWEEN HEAD & SILL MEMBERS. DO NOT LOCATE SPLICE DIRECTLY UNDER A VERTICAL MULLION. DOW CORNING 795 PROCEDURE FOR INSTALLING KAWNEER XPANDR SPLICE SLEEVE FORCE SEALANT UNDER XPANDR AND SEAL EXPOSED JOINT. TOOL SEALANT FLUSH 1/2" JOINT SEAL BACK OF EXPOSED JOINT SPLICE SLEEVE 1. Cut XPANDR Splice Sleeve (27-094) to length and form using a putty knife to bend the material square. 2. Clean splice area with solvent. 3. Apply bead of DOW 795 silicone within 1/4" of the edge of the sill members on each side of the 1/2" joint. 4. Remove protective liner from adhesive tape. (For cold weather applications see Note below) 5. Center the XPANDR splice sleeve over joint. Then, using a putty knife, seat the XPANDR into corner and onto surface of sill member. 6. Sealant will squeeze out through holes. use putty knife to tool off excess silicone. 7. Seal back of exposed joint and apply perimeter seals. Be sure to force sealant up under the XPANDR Splice Sleeve in front. COLD WEATHER NOTE: For temperatures below 40 the following precautions should be taken. Just prior to installing XPANDR, wipe flashing material with a solvent or cleaning solution recommended by the sealant manufacturer. This will remove any condensation or frost that may be present. CAUTION: Carefully follow the recommendations contained in the material safety data sheet provided by the solvent/cleaning solution manufacturer regarding health and fire/explosion risks.

33 FEBRUARY, SECTION VI - INSTALLATION SPLICE JOINT AT CORNER CONDITIONS - SCREW SPLINE & SHEAR BLOCK FABRICATION 90 AND 135 CORNERS STEP A: Miter two 12" sections of sill flashing to correct angle. STEP B: Set mitered joint in a bed of sealant and securely anchor corner into place with a tight joint. STEP C: Completely seal non-moving mitered joint and anchors. STEP D: Use XPANDR splice sleeve at point 12" from corner. CL OF SPLICE 12" (304.8) C L OF SPLICE COMPLETELY SEAL NON-MOVING CORNER JOINT AND ANCHORS 12" (304.8) SECURELY ANCHOR CORNER 12" (304.8) SECURELY ANCHOR CORNER TYPICAL 135 CORNER JOINT COMPLETELY SEAL NON-MOVING CORNER JOINT AND ANCHORS 12" (304.8) TYPICAL 90 CORNER JOINT C L OF SPLICE C L OF SPLICE

34 34 FEBRUARY, 2012 SECTION VI - INSTALLATION SPLICE JOINTS - TYPE B FABRICATION PERIMETER MEMBERS Splice Sleeve Installation at Sill. XPANDR SPLICE SLEEVE CUT TO FIT INTERIOR SEAL DOW CORNING 795

35 FEBRUARY, SECTION VI - INSTALLATION GENERAL INSTALLATION STEPS STEP 1: STEP 2: STEP 3: STEP 4: STEP 5: STEP 6: STEP 7: Apply sealant to the upstanding leg on the flashing. Position the assembled frame into opening to align with sill flashing. (Take care to not push back into sealant) Check that the unit is level and plumb. Push frame back into the sealant. Insert shims as needed and anchor through the glass pocket. Seal all fasteners at sill. Install glazing clips as shown.glazing clips should be located 3" from each end of member and subsequently spaced per the clip spacing chart (See Page 12). Extension leg of glazing clips (shown below) alternates on intermediate vertical mullion to act as side blocks and should be positioned above the horizontal tongue on intermediate horizontal mullion. NOTE: If heavy mullion or steel reinforcing is used, extra perimeter fasteners may be required. Consult your Area Application Engineering Department. Using standard side cutters/snips to crimp mullion dart above and below the TOP and BOTTOM CLIPS on all vertical mullions and jambs. COLD WEATHER NOTE: For temperatures below 40 the following precautions should be taken. Just prior to installing the water deflector, wipe glazing pocket with a solvent or cleaning solution recommended by the sealant manufacturer. This will remove any condensation or frost that may be present. CAUTION: Carefully follow the recommendations contained in the material safety data sheet provided by the solvent/ cleaning solution manufacturer regarding health and fire/ explosion risks. WATER DEFLECTOR ( ) (Use on 1" system intermediate horizontal joints except at SSG mullions. ) Glazing Clip Installation Tool ( ) SEAL IN PLACE NOTE: LEG IS ALWAYS ON TOP Drill clearance holes as required through flashing.apply sealant in hole before screwing sill down. Seal and tool over screw heads at the sill ONLY. Seal and tool over face joint at the bottom of all verticals and jambs.

36 36 FEBRUARY, 2012 SECTION VI - INSTALLATION 1/4" INFILL SYSTEM ONLY STEP 1: END DAM SEALS Where the horizontal meets the vertical, run a 1/4" high bead of sealant out to the front edge of the dart. This will stop any water from running off the ends of the horizontals. 1" INFILL SSG SYSTEM ONLY NOTE: This method of end dam sealing will not work with the standard 1" shear block or screw spline systems

37 FEBRUARY, 2012 SECTION VI - INSTALLATION PERIMETER CAULKING (All Systems) 37 When interior seals are required Snap-in Styrofoam filler or Optional aluminum snap-in filler. Backer Rod must be behind the front wall and vertical weatherings before sealing and tooling sealant. Backer Rod Sealant Bridge sealant to exterior vertical seal at head. Backer Rod Sealant Sealant between sill flashing and corner sheet. Apply angle at head as needed for support of backer rod and sealant. ( ) Weathering with.090 aluminum sheet or sealant with.125 aluminum sheet

38 38 FEBRUARY, 2012 SECTION VI - INSTALLATION OPTIONAL MULLION CAP (All Systems) FABRICATION NOTE: The tested method of perimeter caulking EnCORE will leave an opening at the top of the vertical cover. (See Detail Below). If EnCORE is installed in a building condition (i.e. Sheer Wall, etc.) that would allow water to enter directly into this opening. Kawneer recommends end capping mullions or jambs and sealing the top of vertical covers as shown to prevent an excessive amount of water from entering the system. Contact Kawneer Application Engineering Department for assistance in reviewing individual conditions. NOTE: Capping mullions and jambs will provide the option of running perimeter seals straight across the opening versus the standard method of sealing back along vertical mullion cavities. See page 37 for comparison. DOUBLE FACE TAPE MULLION CAP SEALANT DOUBLE FACE TAPE REMOVABLE PAPER LINER MULLION CAP BUTTER WITH SEALANT BACKER ROD SEAL OVER OPENING 0.125

39 FEBRUARY, 2012 SECTION VII - GLAZING STANDARD GLAZING ( ) Setting Block used with Standard sill and light horizontals. ( ) Setting Block used with 1-1/4" sill and heavy horizontals. 39 Tear setting blocks in half for 1/4" systems. DO NOT SEAL BETWEEN SILL AND SILL FLASHING SET GLASS AND APPLY TEMPORARIES Note: If winds greater than 50 MPH are expected, vertical covers must be installed before leaving the job site. Install horizontal and vertical Temporary Clips ( ) at quarter points on each lite of glass. Use side cutters/snips to remove one leg from ( ) Temporary Clip when glazing 1-1/4" narrow perimeter. Glazing Clip Installation Tool ( ) Setting Block HORIZONTAL WEEP BAFFLE Rubber Mallet may be used in lieu of Installation Tool Install a 6" length of weathering at each end of horizontals. Start at mullion and run under horizontal as shown. 6

40 40 FEBRUARY, 2012 SECTION VII - GLAZING STANDARD GLAZING TEMPORARY CLIP REMOVAL Pry temporary glazing clips off with screw driver as shown. NOTE: TEMPORARY CLIPS CAN NOT BE REUSED OR LEFT UNDER THE COVERS. SSG GLAZING TEMPORARIES TAPE STEP 2: SET GLASS AND SEAL INTERIOR Install setting blocks as before and set your glass. Alternately install Temporary Glazing Clips ( ) every 12" on center. Tape and seal the interior as shown. TAPE STEP 3: SEAL EXTERIOR After the interior seal is fully cured, remove the Temporary Glazing Clips. Tape and seal the exterior as shown.

41 FEBRUARY, 2012 SECTION VII - GLAZING INSTALLATION OF OPTIONAL TEMPORARIES Cut six inch cover temporaries and weathering from scrap. 41 Apply extra glazing clip ( ) to mullions and perimeters at quarter points and weathering (27-074) to both sides of temporary as shown. 6 INCH LENGTH NOTE: Crimp top end of vertical temporaries. Install horizontal and vertical temporary clips at quarter points for each lite of glass. TEMPORARY REMOVAL Pull weathering from temporary and slide it off the extra clip. The extra clip can be left in place.

42 42 FEBRUARY, 2012 SECTION VII - GLAZING SEALING INSTRUCTIONS 1. HORIZONTAL SCREW SEAL 2. WEATHERING CHANNEL SEAL (Required at all horizontal connections) Insert nozzle and force sealant into vertical glazing reglet as shown. NOTE: Do not allow sealant to contact glass laminates or glass sealants. 1 2

43 FEBRUARY, SECTION VII - GLAZING STANDARD WEEPS ARE CREATED BY CUTTING BACK WEATHERING IN COVER ON EACH SIDE OF VERTICAL MULLIONS. OPTIONAL WEEP IN COVER SSG WEEP AT SILL 1" 1" C L On bottom of cover Drill 5/16" Dia. hole 1" from each end of cover to center line of hole. Matching horizontal covers, splice sill covers at center line of mullion. Seal splice joint leaving 1/2" high weep space at bottom of face. C L Drill 5/16" weep holes on the face or bottom of cover at mullion locations between splice joints. COVER SPLICE JOINTS (SPLICE REQUIRED EVERY SECOND VERTICAL) Cut to fit XPANDR (27-094) to splice covers at verticals. Seal to match the vertical seal joint. NOTE: For this weep option a shim space is required.

44 44 FEBRUARY, 2012 SECTION VII - GLAZING COVER INSTALLATION Install vertical covers first using small pieces of weathering as spacers between glass and cover. This will create space for weathering installation later. Horizontal covers should be centered at installation to allow a 1/32" expansion gap on both ends. A large soft rubber mallet may be used for cover installation. Be careful, the use of too much force may result in dented covers. NOTE: Gaskets may be pre-installed into covers.cover installation force will be increased. Vertical gaskets must be cut at horizontal tongue.

45 FEBRUARY, 2012 SECTION VII - GLAZING 1. STUFFED WEATHERING SEAL Apply sealant into horizontal glazing reglet on bottom side of intermediate horizontal and at head as shown INSTALL WEATHERING After the covers are installed, the interior weathering can be installed. Installation in this order allows for glass repositioning. NOTE: Weathering at the interior head and sill members must be overstuffed.

46 46 FEBRUARY, 2012 SECTION VIII - ENTRANCE FRAMING 1. Check opening, allowing clearance at sides and top so that frame may be plumbed, squared and shimmed. 2. If jambs must be shortened, move the pocket inserts for the transom area flush with the top ends of the vertical jamb. Cut the jambs, including inserts, to the desired length allowing for clearance. 3. Use the appropriate templates for Header/T-bar Clips from Door Frame Fabrication/Installation Section of the Installation Manual to locate holes for the header clips.drill holes and attach clips to vertical jambs. Apply sealant to the exposed bearing surfaces.position header on clips and secure in place. 4. Apply sealant to the exposed surfaces of the factory-applied transom bar clips and secure transom bar. SET THRESHOLD INTO BED OF SEALANT 1-3/4" SEALANT 5/8" GLASS HEIGHT 1-3/4" INSTALLER NOTE: FOR 1/4" GLASS ADAPTER TO RUN CONTINUOUS W/SEALANT GLASS WIDTH AT TRANSOM 1/4" ADAPTER SETTING BLOCK SETTING BLOCK W BLOCK DOOR JAMB POCKET INSERT SEALANT TRANSOM BAR CLIP SEALANT HEADER CLIP (#10 x 1-19/32" P.H.) (#10 x 9/16" F.H.) HEADER SEALANT NOTE: SEAL GLASS POCKET OF DOOR JAMB AT SILL. NOTE: SEAL JUST BEFORE INSTALLATION OF UNIT. (Continuous bead behind all sill) GLASS STOP TRANSOM BAR SEALANT INTERIOR STOP ONLY

47 FEBRUARY, SECTION VIII - ENTRANCE FRAMING 1. Position assembled frame plumb and square in opening. 2. Shim and secure jambs and header in opening. 3. Secure threshold (if supplied) to floor. 4. Install closer per instructions included in the closer package. 5. Glaze transom: A. Snap in interior glass stop on to transom bar. Apply bead of sealant to front leg of stop as shown. B. Pre-cut horizontal and vertical push-on gasket allowing 1/2" extra. C. Insert interior push-on gasket into glass stop and remaining three glazing pockets (vertical transom jambs and header). Run horizontal gaskets through and butt vertical gaskets in-between. D. Position glass into transom area and place setting blocks on transom bar at 1/4 points. E. Snap remaining glass stops into transom bar. Snap on transom cover where required. Insert exterior push-on gaskets into glazing pockets. TRANSOM COVER BACKER ROD & SEAL HEADER CLIP (#10 x 1-19/32" P.H.) (#10 x 9/16" F.H.) HEADER TRANSOM BAR CLIP NOTE: Consult factory when field fabrication is required for locking hardware. 3/8" GLASS WIDTH DOOR JAMB ASSEMBLY SEALANT INSTALLER NOTE: FOR 1/4" GLASS ADAPTER TO RUN CONTINUOUS W/ SEALANT BACKER ROD & SEAL AT TRANSOM (#10 X 9/16" F.H. 3" from each end and 12: O.C.) DOOR JAMB ADAPTER SEALANT TRANSOM BAR (10 X 11/16" P.H. 3" from each end and 12" O.C.) GLASS STOP SEALANT INTERIOR STOP ONLY DOOR JAMB ADAPTER HOLE PLUG

48 48 FEBRUARY, 2012 SECTION IX - DEGLAZING Remove vertical weathering using a weathering removal tool, be careful not to damage weathering that will be reused. Starting at the bottom of the vertical cover, place a sharp wide blade scraper between the cover and the glass. Slide the scraper until you find the top of the first clip with the scraper edge. Push the clip to the bottom of the cover. The first and last clips will be harder to push as they are crimped into place. Continue this process until all the clips are stacked at the bottom of the cover. Pull out on the cover and slide it off the clips.you may have to use the scraper to hold the clips in place when removing the cover. After covers are removed, replace all glazing clips before re-glazing. This must be done even if clips don't appear to be damaged. WEATHERING REMOVAL TOOL

INSTALLATION INSTRUCTIONS. EnCORE CAPTURED & SSG SCREW SPLINE SHEAR BLOCK TYPE B LITHO IN U.S.A. JANUARY KAWNEER COMPANY, INC

INSTALLATION INSTRUCTIONS. EnCORE CAPTURED & SSG SCREW SPLINE SHEAR BLOCK TYPE B LITHO IN U.S.A. JANUARY KAWNEER COMPANY, INC INSTALLATION EnCORE CAPTURED & SSG SCREW SPLINE SHEAR BLOCK TYPE B INSTRUCTIONS LITHO IN U.S.A. JANUARY KAWNEER COMPANY, INC. 2004 175-970.01.04 PART NO. 175-970 INSTALLATION INSTRUCTIONS CONTENTS These

More information

DHS-500 IMPACT SYSTEM INSTALLATION MANUAL

DHS-500 IMPACT SYSTEM INSTALLATION MANUAL DHS-500 IMPACT SYSTEM INSTALLATION MANUAL TABLE OF CONTENTS SECTION PAGE GENERAL NOTES 3 EXTRUSION & PARTS IDENTIFICATION 4-5 DETERMINE FRAME SIZE 6 FABRICATE VERTICAL MULLIONS & FILLERS 7-8 FABRICATE

More information

INSTALLATION INSTRUCTIONS TRIFAB VG SCREW SPLINE ASSEMBLY TRIFAB VG 450 TRIFAB VG 451 TRIFAB VG 451T

INSTALLATION INSTRUCTIONS TRIFAB VG SCREW SPLINE ASSEMBLY TRIFAB VG 450 TRIFAB VG 451 TRIFAB VG 451T INSTALLATION TRIFAB VG SCREW SPLINE ASSEMBLY TRIFAB VG 450 TRIFAB VG 451 TRIFAB VG 451T INSTRUCTIONS LITHO IN U.S.A. JANUARY KAWNEER COMPANY, INC., 2004 451-VG-970.01.04a PART NO. 451-VG-970 1 INSTALLATION

More information

INSTALLATION INSTRUCTIONS TRIFAB 451UT SCREW SPLINE ASSEMBLY TRIFAB 451UT. AUGUST, 2010 (Part No. 452T-CG-970) EC

INSTALLATION INSTRUCTIONS TRIFAB 451UT SCREW SPLINE ASSEMBLY TRIFAB 451UT. AUGUST, 2010 (Part No. 452T-CG-970) EC AUGUST, 2010 (Part No. 452T-CG-970) EC 97904-31 1 INSTALLATION SCREW SPLINE ASSEMBLY Kawneer Company, Inc., 2010 INSTRUCTIONS 2 TABLE OF CONTENTS (452T-CG-970) AUGUST, 2010 These instructions show the

More information

Storefront Installation Guide

Storefront Installation Guide Storefront General Notes: 1. Check Contract Documents and Shop Drawings. Understand and clarify any Field Verify Notes and approvals of drawings and products to be familiar with the project. Installation

More information

14000 I/O Series Flush Glaze. Fabrication and Installation Instructions

14000 I/O Series Flush Glaze. Fabrication and Installation Instructions 14000 I/O Series Flush Glaze Fabrication and Installation Instructions Last saved on 12/18/2009 Table of Contents GENERAL CONSTRUCTION NOTES...3 EXTRUDED ALUMINUM PARTS...4 ACCESSORIES...5 OVERVIEW...6

More information

4500 Series. Fabrication and Installation Instructions

4500 Series. Fabrication and Installation Instructions 4500 Series Fabrication and Installation Instructions E4500 Series July, 2017 Table of Contents GENERAL CONSTRUCTION NOTES... 3 EXTRUDED ALUMINUM PARTS... 5 ACCESSORIES... 7 OVERVIEW... 8 FRAME FABRICATION...

More information

Series Sloped glazed Curtain wall. Installation Instructions

Series Sloped glazed Curtain wall. Installation Instructions Series 5600 Sloped glazed Curtain wall Installation Instructions Part NO. Y308 February 2013 SECTION TABLE OF CONTENTS PAGE I. General Notes & Guidelines. 3-4 II. Gutter and Mullion Assembly.. 5 III. End

More information

14000 Series. Fabrication and Installation Instructions

14000 Series. Fabrication and Installation Instructions 14000 Series Fabrication and Installation Instructions Revision May 2013 Table of Contents GENERAL CONSTRUCTION NOTES...3 EXTRUDED ALUMINUM PARTS...5 ACCESSORIES...8 OVERVIEW...10 FRAME FABRICATION...15

More information

YES 600 Thermal Clip Storefront System Installation Manual

YES 600 Thermal Clip Storefront System Installation Manual Installation Manual 2004 YKK AP America Inc. is a subsidiary of YKK Corporation of America. TABLE OF CONTENTS Installation Notes........................................ Page ii Frame Types............................................

More information

14000 Series. Fabrication and Installation Instructions

14000 Series. Fabrication and Installation Instructions 14000 Series Fabrication and Installation Instructions 14000 Series Revision December 01, 2009 Table of Contents GENERAL CONSTRUCTION NOTES... 3 EXTRUDED ALUMINUM PARTS... 4 ACCESSORIES... 7 OVERVIEW...

More information

Note: Installation and Glazing Manuals are product specific. FOR REVIEW ONLY! May 2015

Note: Installation and Glazing Manuals are product specific. FOR REVIEW ONLY! May 2015 Note: Installation and Glazing Manuals are product specific. FOR REVIEW ONLY! May 2015 Phone: 1-866-OLDCASTLE (653-2278) Web Address: www.oldcastlebe.com S E R I E S 6 0 0 0 X T - S T O R E F R O N T I

More information

GENERAL INSTALLATION GUIDELINES

GENERAL INSTALLATION GUIDELINES 1551 MT. ROSE AVENUE YORK PA 17403-2909 (717) 849-8100 GENERAL INSTALLATION GUIDELINES For Receptor Systems Approved 08/31/2018 Installation Guideline Disclaimer This document contains general installation

More information

YES 40 FS/FI Storefront System Installation Manual

YES 40 FS/FI Storefront System Installation Manual Installation Manual 2014 YKK AP America Inc. is a subsidiary of YKK Corporation of America. TABLE OF CONTENTS Installation Notes... Page ii PARTS DESCRIPTION YES 40 FS Framing Members... Page 1 YES 40

More information

GENERAL INSTALLATION GUIDELINES

GENERAL INSTALLATION GUIDELINES 1551 MT. ROSE AVENUE YORK PA 17403-2909 (717) 849-8100 GENERAL INSTALLATION GUIDELINES For Receptor Systems Approved 9/29/2017 Installation Guideline Disclaimer This document contains general installation

More information

YES 45 TU Thermal Storefront System Installation Manual

YES 45 TU Thermal Storefront System Installation Manual Installation Manual 2004 YKK AP America Inc. is a subsidiary of YKK Corporation of America. TABLE OF CONTENTS Installation Notes........................................ Page ii PARTS DESCRIPTION Framing

More information

INSTALLATION INSTRUCTIONS SIDELITE ASSEMBLY SERIES 900 TERRACE DOOR AND SERIES 925 PATIO DOOR

INSTALLATION INSTRUCTIONS SIDELITE ASSEMBLY SERIES 900 TERRACE DOOR AND SERIES 925 PATIO DOOR INSTALLATION INSTRUCTIONS SIDELITE ASSEMBLY SERIES 900 TERRACE DOOR AND SERIES 925 PATIO DOOR Phone: (800) 262-5151 Fax: (866) 262-3299 crlaurence.com usalum.com crl-arch.com 11M0292 HANDLING, STORAGE,

More information

YWE 40 T Window Wall System Installation Manual

YWE 40 T Window Wall System Installation Manual Installation Manual 2005 YKK AP America Inc. is a subsidiary of YKK Corporation of America. TABLE OF CONTENTS Installation Notes........................................ Page ii Frame Types............................................

More information

Series Advanced and alternate. Installation Instructions

Series Advanced and alternate. Installation Instructions Series 5500 Advanced and alternate Installation Instructions Part NO. Y557 February 2013 TABLE OF CONTENTS SECTION S-5500 ADVANCED INSTALLATION INSTUCTIONS PAGE I. General Notes and Guidelines...... 3-4

More information

INSTALLATION INSTRUCTIONS SERIES 487 CENTER GLAZED WITH 1-1/2" TRIM OFFICE PARTITIONS

INSTALLATION INSTRUCTIONS SERIES 487 CENTER GLAZED WITH 1-1/2 TRIM OFFICE PARTITIONS INSTALLATION INSTRUCTIONS SERIES 87 CENTER GLAZED WITH -/" TRIM OFFICE PARTITIONS Phone: (800) -6 Fax: (800) 58-7 crlaurence.com usalum.com crl-arch.com M056_Rev_D SERIES 87 OFFICE PARTITIONS CENTER GLAZED

More information

INSTALLATION INSTRUCTIONS 2 x 4 1/2 for 1 Glass

INSTALLATION INSTRUCTIONS 2 x 4 1/2 for 1 Glass INSTALLATION INSTRUCTIONS 2 x 4 1/2 for 1 Glass Deep pocket allows for direct anchor attachment to substrate without flat filler plate. 1/4 Ø perimeter anchor holes allows for direct anchor attachment

More information

Installation Instructions

Installation Instructions Installation Instructions 200 Series Curtainwall 3056 WALKER RIDGE DR. NW, SUITE G WALKER, MI 49544 800-866-2227 dependable@tubeliteinc.com Revised April 2014 dependable@tubeliteinc.com Page 1 TABLE OF

More information

YES 45 XT High Performance Thermal Storefront System

YES 45 XT High Performance Thermal Storefront System Dual Thermal Barrier ThermaBond Plus Pour & Debridge Technology Installation Manual 2015 YKK AP America Inc. is a subsidiary of YKK Corporation of America. TABLE OF CONTENTS Installation Notes... Page

More information

YSG 40/50/50T Window Wall System Installation Manual

YSG 40/50/50T Window Wall System Installation Manual Installation Manual 2004 YKK AP America Inc. is a subsidiary of YKK Corporation of America. TABLE OF CONTENTS Installation Notes........................................ Page ii PARTS DESCRIPTION YSG 40

More information

YCW 752 Outside Glazed Curtain Wall System Installation Manual

YCW 752 Outside Glazed Curtain Wall System Installation Manual YCW 752 Outside Glazed Curtain Wall System Installation Manual 2007 YKK AP America Inc. is a subsidiary of YKK Corporation of America. TABLE OF CONTENTS Installation Notes........................................

More information

FG-5100T STORMMAX INSTALLATION AND GLAZING MANUAL NOTE:

FG-5100T STORMMAX INSTALLATION AND GLAZING MANUAL NOTE: BuildingEnvelope R FG-5100T STORMMAX INSTALLATION AND GLAZING MANUAL NOTE: THE INSTALLATION DETAILS FOUND IN THIS PACKAGE ARE GENERIC AND ARE FOR REPRESENTATION ONLY WITH THE INTENT OF GIVING THE INSTALLATION

More information

YES 45 FS/FI Storefront System Installation Manual

YES 45 FS/FI Storefront System Installation Manual Installation Manual 2014 YKK AP America Inc. is a subsidiary of YKK Corporation of America. TABLE OF CONTENTS Installation Notes... Page ii PARTS DESCRIPTION YES 45 FS Framing Members... Page 1 YES 45

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS 900 SERIES RIBBON WINDOW INSTALLATION INSTRUCTIONS 3056 Walker Ridge Dr. NW, Suite G Walker, MI 49544 800-866-2227 November 2016 www.tubeliteinc.com Page 1 TABLE OF CONTENTS GENERAL CONSTRUCTION NOTES...3-4

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS MARCH, 2009 PART NUMBER 590-500 1 INSTALLATION INSTRUCTIONS 2 INDEX MARCH, 2009 INSTALLATION INSTRUCTIONS CONTENTS These instructions show the general installation sequence and procedure for typical installation.

More information

YCW 750 IG Inside Glazed Curtain Wall System Installation Manual

YCW 750 IG Inside Glazed Curtain Wall System Installation Manual Installation Manual 2014 YKK AP America Inc. is a subsidiary of YKK Corporation of America. TABLE OF CONTENTS Installation Notes... Page ii PARTS DESCRIPTION YCW 750 IG Framing Members... Page 1 to 3

More information

Note: Installation and Glazing Manuals are product specific. FOR REVIEW ONLY! FEBRUARY 2012

Note: Installation and Glazing Manuals are product specific. FOR REVIEW ONLY! FEBRUARY 2012 Note: Installation and Glazing Manuals are product specific. FOR REVIEW ONLY! Phone: 1-866-OLDCASTLE (653-2278) Web Address: www.oldcastlebe.com FG-1000 & FG-2000 INSTALLATION & GLAZING INSTRUCTIONS These

More information

YCW 750 OG Outside Glazed Curtain Wall System Installation Manual

YCW 750 OG Outside Glazed Curtain Wall System Installation Manual YCW 750 OG Outside Glazed Curtain Wall System Installation Manual 2004 YKK AP America Inc. is a subsidiary of YKK Corporation of America. TABLE OF CONTENTS Installation Notes........................................

More information

Note: Installation and Glazing Manuals are product specific. FOR REVIEW ONLY! OCTOBER Phone: OLDCASTLE ( ) Web Address:

Note: Installation and Glazing Manuals are product specific. FOR REVIEW ONLY! OCTOBER Phone: OLDCASTLE ( ) Web Address: Note: Installation and Glazing Manuals are product specific. FOR REVIEW ONLY! TABLE OF CONTENTS General Information............................. Page 2 4 Outside Glaze Non Thermal...............................Page

More information

Table of Contents. Typical elevation & cut lengths. General construction notes. General installation notes. Typical jamb assembly

Table of Contents. Typical elevation & cut lengths. General construction notes. General installation notes. Typical jamb assembly c CD $ a c Q / / Table of Contents Page Description 1 Parts list 2 3 4 5 6 Typical elevation & cut lengths General construction notes General installation notes Typical jamb assembly Typical intermediate

More information

TCR 250 THERMAL COMPOSITE RIBBON WINDOW

TCR 250 THERMAL COMPOSITE RIBBON WINDOW CORRECT DRO OVER THE 5/8" 1" TOP OF HORIZONTAL 1 1/4" 2 3/8" SEAL THIS ACCESS HOLE ONLY 2 3/4".191 DIA. TAP HOLE FOR #14 SCREW DETAIL AT INCIDENTAL WATER APPLICATION STRAP ANCHOR DESIGNED ON A PER-JOB

More information

Series Exterior glazed curtain wall. Installation Instructions

Series Exterior glazed curtain wall. Installation Instructions Series 5500 Exterior glazed curtain wall Installation Instructions Part NO. Y550 November 2016 TABLE OF CONTENTS SECTION S-5500 SCREW SPLINE CURTAIN WALL PAGE I. General Notes and Guidelines.. 3-4 II.

More information

SERIES 406X. Installation Instructions. Place photography here. Don t go over grey area. (size w x h )

SERIES 406X. Installation Instructions. Place photography here. Don t go over grey area. (size w x h ) SERIES 406X Installation Instructions Place photography here. Don t go over grey area (size 7.9961 w x 7.4561 h ) Table of Contents Section 1. General Notes and Guidelines. 2. Parts Identification Charts

More information

NARROW, MEDIUM AND WIDE STILE, THERMASTILE AND DURASTILE. Installation Instructions

NARROW, MEDIUM AND WIDE STILE, THERMASTILE AND DURASTILE. Installation Instructions NARROW, MEDIUM AND WIDE STILE, THERMASTILE AND DURASTILE Installation Instructions PART Y015 JUNE 2016 Table of Contents Section 1. GENERAL NOTES AND GUIDELINES... 2. DOOR HARDWARE A. Locks B. Push/Pulls

More information

YSD 400 Sliding Door System Installation Manual

YSD 400 Sliding Door System Installation Manual System Installation Manual 2006 YKK AP America Inc. is a subsidiary of YKK Corporation of America. TABLE OF CONTENTS Installation Notes........................................ Page ii PARTS DESCRIPTION

More information

INSTALLATION INSTRUCTIONS. Thermal Entrances AA 250/AA 425 THERMAL DOOR WITH TRIFAB 601/601T FRAMING

INSTALLATION INSTRUCTIONS. Thermal Entrances AA 250/AA 425 THERMAL DOOR WITH TRIFAB 601/601T FRAMING JANUARY, 2014 1 INSTALLATION Thermal Entrances AA 250/AA 425 THERMAL DOOR WITH TRIFAB 601/601T FRAMING INSTRUCTIONS 2 FRAME ASSEMBLY JANUARY, 2014 601442 SHEAR BLOCK BALL BEARING NRP BUTT (FACTORY APPLIED

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS 400T SERIES CURTAIN WALL INSTALLATION INSTRUCTIONS 3056 Walker Ridge Dr. NW, Suite G Walker, MI 49544 800-866-2227 October 2017 www.tubeliteinc.com Page 1 BLANK Page 2 www.tubeliteinc.com October 2017

More information

INSTALLATION INSTRUCTIONS 2 1/2 x 7 for 1 Glass

INSTALLATION INSTRUCTIONS 2 1/2 x 7 for 1 Glass INSTALLATION INSTRUCTIONS 2 1/2 x 7 for 1 Glass Captured System 3010 Rice Mine Road, Tuscaloosa, Alabama 35406 1-800-772-7737 Fax 1-800-443-6261 www.coralind.com A Division of Coral Industries, Inc. B.G.

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS Thermally Broken Framing and Door Installation SL-450TB (2" x 4-1/2" with 1" Glazing) & SL-600TB (2" x 6" with 1" Glazing) IMPORTANT: Read all instructions before beginning installation.

More information

Thermally Broken Framing and Door Installation

Thermally Broken Framing and Door Installation INSTALLATION INSTRUCTIONS Thermally Broken Framing and Door Installation IMPORTANT: Read all instructions before beginning installation. These instructions are provided to help prevent installation problems

More information

SERIES 5001 SLIDING GLASS DOOR PATIO DOORS INSTALLATION GUIDE

SERIES 5001 SLIDING GLASS DOOR PATIO DOORS INSTALLATION GUIDE PATIO DOORS INSTALLATION GUIDE These instructions cover general installation conditions. Improper installation could affect your doors operation and warranty. Deviations from these instructions should

More information

Series 955 Tech Set storefront. Installation Instructions

Series 955 Tech Set storefront. Installation Instructions Series 955 Tech Set storefront Installation Instructions Part NO. Y008 February 2013 TABLE OF CONTENTS SECTION PAGE I II III GENERAL NOTES AND GUIDELINES 1-2 PARTS IDENTIFICATION 3-5 DRILL JIGS 6-7 DRILL

More information

Series 6000 THERMAL MULTI-PLANE INSTALLATION AND GLAZING MANUAL

Series 6000 THERMAL MULTI-PLANE INSTALLATION AND GLAZING MANUAL Series 6000 THERMAL MULTI-PLANE INSTALLATION AND GLAZING MANUAL Note: Installation and Glazing Manuals are product specific. FOR REVIEW ONLY! TABLE OF ONTENTS General Information... p.2 Frame Fabrication...

More information

Series 406 storefront. Installation Instructions

Series 406 storefront. Installation Instructions Series 406 storefront Installation Instructions Part NO. Y016 February 2013 Series 406 Installation Instructions TABLE OF CONTENTS Section I GENERAL NOTES Page 1 II PARTS IDENTIFICATION Page 2-3 III FABRICATION

More information

YCW 750 OG Outside Glazed Curtain Wall System Installation Manual

YCW 750 OG Outside Glazed Curtain Wall System Installation Manual YCW 750 OG Outside Glazed Curtain Wall System Installation Manual 2012 YKK AP America Inc. is a subsidiary of YKK Corporation of America. TABLE OF CONTENTS Installation Notes... Page ii PARTS DESCRIPTION

More information

YHC 300 SSG Structural Silicone Glazed Curtain Wall System Installation Manual

YHC 300 SSG Structural Silicone Glazed Curtain Wall System Installation Manual YHC 300 SSG Structural Silicone Glazed Curtain Wall System Installation Manual 2007 YKK AP America Inc. is a subsidiary of YKK Corporation of America. TABLE OF CONTENTS Installation Notes........................................

More information

IF THE END REACTION IS 350# TO 750# THE FOLLOWING PERIMETER ANCHORING CAN BE USED. HEAD AND SILL CONDITIONS WITH EXPOSED INTERIORS SHIMS

IF THE END REACTION IS 350# TO 750# THE FOLLOWING PERIMETER ANCHORING CAN BE USED. HEAD AND SILL CONDITIONS WITH EXPOSED INTERIORS SHIMS 162-960 1 OF 5 USE THESE INSTRUCTIONS IN CONJUNCTION WITH INSTALLATION INSTRUCTIONS 162-970. PERIMETER ANCHORING TO CALCULATE END REACTIONS MODULE(FT) X LENGTH(FT) X WIND LOAD(PSF) A IF THE END REACTION

More information

SERIES BW3250 BLAST WALL TABLE OF CONTENTS INSTALLATION INSTRUCTIONS GENERAL NOTES

SERIES BW3250 BLAST WALL TABLE OF CONTENTS INSTALLATION INSTRUCTIONS GENERAL NOTES I N S TA L L AT I O N I N S T R U C T I O N S BW3250 BLAST RESISTANT CURTAIN WALL Page 2 SERIES BW3250 BLAST WALL TABLE OF CONTENTS United States Aluminum PAGE GENERAL NOTES...2 and 3 FABRICATION...4 through

More information

Storefront Installation Guide INSTALLATION INSTRUCTIONS

Storefront Installation Guide INSTALLATION INSTRUCTIONS STOREFRONT General Notes 1. Check contract documents and shop drawings, and understand and clarify any Field Verify Notes, approvals of drawings, and products required to be familiar with the project.

More information

Series 960 wall storefront. Installation Instructions

Series 960 wall storefront. Installation Instructions Series 960 wall storefront Installation Instructions Part NO. Y005 February 2013 960 WALL TALE OF CONTENTS JWH 8/2011 SECTION I II III GENERAL NOTES PARTS IDENTIFICATION SCREW SPLINE FARICATION PAGE 1

More information

SECTION C1 INSTALLATION INSTRUCTIONS

SECTION C1 INSTALLATION INSTRUCTIONS SECTION C1 SERIES CWW451T THERMALLY BROKEN FRONT GLAZED WINDOW WALL / STOREFRONT SYSTEM X 4 1 / for 1" GLAZING INSTALLATION INSTRUCTIONS EXTERIOR GLAZED Effective October 2014 www.cardcompro.com 1 INTERIOR

More information

SERIES CF450 INSTALLATION INSTRUCTIONS. SERIES CF450 1¾ x 4½ - B1. Fabrication for Panel Assembly. High Performance Non-Thermal Storefront System

SERIES CF450 INSTALLATION INSTRUCTIONS. SERIES CF450 1¾ x 4½ - B1. Fabrication for Panel Assembly. High Performance Non-Thermal Storefront System SERIES CF450 INSTALLATION INSTRUCTIONS Fabrication for Panel Assembly High Performance Non-Thermal Storefront System Effective October 2014 www.cardcompro.com 1 2 www.cardcompro.com Effective October 2014

More information

Sun Control-Solar Eclipse-Solar Shelf

Sun Control-Solar Eclipse-Solar Shelf Sun Control-Solar Eclipse-Solar Shelf Note: Installation and Glazing Manuals are product specific. FOR REVIEW ONLY! TABLE OF CONTENTS GENERAL INFORMATION Product Use...Page 3 Protection and Storage...Page

More information

ELEPHANT DOOR SYSTEMS SERIES E1200

ELEPHANT DOOR SYSTEMS SERIES E1200 INSTALLATION INSTRUCTIONS ELEPHANT DOOR SYSTEMS SERIES E1200 Phone: (800) 262-5151 Fax: (866) 262-3299 crlaurence.com usalum.com crl-arch.com AVDB3096 03.13 TABLE OF CONTENTS SUBJECT PAGE GENERAL INSTALLATION

More information

SERIES CF451T INSTALLATION INSTRUCTIONS. SERIES CF451T 2 x 4½ - B2. Fabrication for Panel Assembly. High Performance Thermal Storefront System

SERIES CF451T INSTALLATION INSTRUCTIONS. SERIES CF451T 2 x 4½ - B2. Fabrication for Panel Assembly. High Performance Thermal Storefront System SERIES CF451T INSTALLATION INSTRUCTIONS Fabrication for Panel Assembly High Performance Thermal Storefront System Effective October 2014 www.cardcompro.com 1 2 www.cardcompro.com Effective October 2014

More information

Series 525 impact storefront. Installation Instructions

Series 525 impact storefront. Installation Instructions Series 525 impact storefront Installation Instructions Part NO. Y020 February 2013 SECTION I GENERAL NOTES II PARTS IDENTIFICATION III FABRICATION A. DRILLING TEMPLATE (SCREW SPLINE VERTICALS) B. DRILLING

More information

Installation Instructions

Installation Instructions Installation Instructions 400 Series Curtainwall 3056 WALKER RIDGE DR. NW, SUITE G WALKER, MI 49544 800-866-2227 dependable@tubeliteinc.com Revised September 2014 dependable@tubeliteinc.com Page 1 TABLE

More information

INSTALLATION INSTRUCTIONS SERIES 3600 SUNSHADE SYSTEM

INSTALLATION INSTRUCTIONS SERIES 3600 SUNSHADE SYSTEM INSTALLATION INSTRUCTIONS SERIES 3600 SUNSHADE SYSTEM Phone: (800) 262-5151 Fax: (866) 262-3299 crlaurence.com usalum.com crl-arch.com 11M0103 HANDLING, STORAGE, AND PROTECTION OF The following precautions

More information

YHC 300 IG Inside Glazed Curtain Wall System Installation Manual

YHC 300 IG Inside Glazed Curtain Wall System Installation Manual YHC 300 IG Inside Glazed Curtain Wall System Installation Manual 2007 YKK AP America Inc. is a subsidiary of YKK Corporation of America. TABLE OF CONTENTS Installation Notes........................................

More information

Theut Company LLC 1317 Bus. Hwy 71 N Columbus, Tx Ph. (979) Fax (979)

Theut Company LLC 1317 Bus. Hwy 71 N Columbus, Tx Ph. (979) Fax (979) Theut Company LLC 1317 Bus. Hwy 71 N Columbus, Tx 78934 Ph. (979) 732-2201 Fax (979) 732-2311 Westside Montessori School Building B Addition Environments, Inc Drymalla Construction February 14, 2013 Installation

More information

SERIES 300 SINGLE HUNG WINDOW INSTALLATION

SERIES 300 SINGLE HUNG WINDOW INSTALLATION IMPORTANT INFORMATION: WHETHER IT BE LOCATION OR INSTALLATION TYPE, NOT ALL WINDOW TYPES CAN BE INSTALLED IN ALL AREAS OR WALL CONDITIONS. CONSULT YOUR LOCAL BUILDING CODE DEPARTMENT FOR ANY REGULATIONS

More information

CURTAIN WALL INSTALLATION AND GLAZING MANUAL

CURTAIN WALL INSTALLATION AND GLAZING MANUAL RELIANCE tm - TC IG CURTAIN WALL INSTALLATION AND GLAZING MANUAL TABLE OF CONTENTS General Information...Page 3-5 Product Use... Page 3 Protection and Storage... Page 3 Check Material... Page 4 Field Conditions...

More information

Heavy Wall Applied Stop Tube Frame and Door Installation

Heavy Wall Applied Stop Tube Frame and Door Installation INSTALLATION INSTRUCTIONS Heavy Wall Applied Stop Tube Frame and Door Installation Read all instructions before beginning installation. These instructions are provided to help prevent installation problems

More information

INSTALLATION MANUAL STOREFRONT DOORS

INSTALLATION MANUAL STOREFRONT DOORS INSTALLATION MANUAL STOREFRONT DOORS www.aluflam-usa.com SYSTEM DESCRIPTION - Extruded and filled aluminum framing, tested and approved by UL - 3-3/8 frame depth - Clear, fire-rated safety glazing - Door

More information

e-lite fabrication/assembly and Installation instructions

e-lite fabrication/assembly and Installation instructions e-lite fabrication/assembly and Installation instructions Part NO. YWLS February 2013 TABLE OF CONTENTS SECTION PAGE I. General Notes and Guidelines.. 3-4 II. E-Lite Stick Built Channel Base Assembly...

More information

INSTALLATION INSTRUCTIONS ENTICE SERIES PREMIUM ENTRANCE SYSTEM EXTERIOR GLAZE

INSTALLATION INSTRUCTIONS ENTICE SERIES PREMIUM ENTRANCE SYSTEM EXTERIOR GLAZE INSTALLATION INSTRUCTIONS ENTICE SERIES PREMIUM ENTRANCE SYSTEM EXTERIOR GLAZE Phone: (800) 421-6144 Fax: (800) 582-7501 crlaurence.com usalum.com crl-arch.com 11M0230 HANDLING, STORAGE, AND PROTECTION

More information

YHS 50 FS Storefront System & Model 35H/50H Door Installation Manual

YHS 50 FS Storefront System & Model 35H/50H Door Installation Manual Installation Manual 2014 YKK AP America Inc. is a subsidiary of YKK Corporation of America. TABLE OF CONTENTS Installation Notes... Page ii PARTS DESCRIPTION YHS 50 Framing Members... Page 1 YHS 50 Accessories...

More information

Swing Door Installation Manual

Swing Door Installation Manual Manual 20D/35D/50D 20DH/35DH 40M/50M 25FD 35XT 50XT 01-4000-03 2010 YKK AP America Inc. is a subsidiary of YKK Corporation of America. TABLE OF CONTENTS Installation Notes.......................................

More information

YHS 50 TU Storefront System & Model 35H Door Installation Manual

YHS 50 TU Storefront System & Model 35H Door Installation Manual Installation Manual 2012 YKK AP America Inc. is a subsidiary of YKK Corporation of America. TABLE OF CONTENTS Installation Notes... Page ii PARTS DESCRIPTION YHS 50 TU Framing Members... Page 1 YHS 50

More information

METL-VISION WINDOW SYSTEM FOR HORIZONTAL WALL PIONEERING INSULATED METAL PANEL TECHNOLOGY

METL-VISION WINDOW SYSTEM FOR HORIZONTAL WALL PIONEERING INSULATED METAL PANEL TECHNOLOGY METL-VISION WINDOW SYSTEM FOR HORIZONTAL WALL Window assembly GUIDE PIONEERING INSULATED METAL PANEL TECHNOLOGY PIONEERING INSULATED METAL PANEL TECHNOLOGY CONTENTS DETAIL TITLE FILE NO. PAGE NO. INTRODUCTION..................................................................

More information

SERIES 300 SINGLE HUNG WITH FIN WINDOW INSTALLATION

SERIES 300 SINGLE HUNG WITH FIN WINDOW INSTALLATION IMPORTANT INFORMATION: WHETHER IT BE LOCATION OR INSTALLATION TYPE, NOT ALL WINDOW TYPES CAN BE INSTALLED IN ALL AREAS OR WALL CONDITIONS. CONSULT YOUR LOCAL BUILDING CODE DEPARTMENT FOR ANY REGULATIONS

More information

Series 526 Thermal impact storefront. Installation Instructions

Series 526 Thermal impact storefront. Installation Instructions Series 526 Thermal impact storefront Installation Instructions Part NO. Y021 February 2013 TABLE OF CONTENTS SECTION PAGE I. General Notes and Guidelines. 3 II. Parts Identification Chart.......4-8 III.

More information

Installation Instructions

Installation Instructions Installation Instructions 1293 N. Harvey Mitchell Pkwy. Bryan, Texas 77803 800.444.1444 ph 979.823.1005 fax www.aswcommercial.com Simplifying Windows Complete Architectural CD Binder Inside B l as t I

More information

RELIANCE -LT INSTALLATION AND GLAZING MANUAL

RELIANCE -LT INSTALLATION AND GLAZING MANUAL RELIANCE -LT INSTALLATION AND GLAZING MANUAL NOTE: THE ASSEMBLY DETAILS FOUND IN THIS PACKAGE ARE GENERIC AND ARE FOR REPRESENTATION ONLY WITH THE INTENT OF GIVING THE ASSEMBLY TEAM A VISUAL REPRESENTATION

More information

YOW 225 TU Window System

YOW 225 TU Window System ThermaBond Plus Poured & Debridged Technology YOW 225 TU SYSTEM DESCRIPTION YOW 225 TU PERFORMANCE FEATURES 2-1/4 Overall Depth ThermaBond Plus Poured & Debridged Thermal Break Variations: Casement, Projected

More information

Series 7600 Installation Instructions Aluminum Multi-Slide Door (Pocketing)

Series 7600 Installation Instructions Aluminum Multi-Slide Door (Pocketing) Series 7600 Installation Instructions Aluminum Multi-Slide Door (Pocketing) Things to Know Before You Start Things to Know Before You Start Removal of Old Fenestration Products Ensure any old fenestration

More information

Block Frame Inovo Patio Door/Transom/Sidelite Field Mulling Instructions. simonton.com/installation. If mulling sidelites, skip to Step 5.

Block Frame Inovo Patio Door/Transom/Sidelite Field Mulling Instructions. simonton.com/installation. If mulling sidelites, skip to Step 5. Effective Date: 10/1/17 Tools Needed Kit Contents Safety Glasses Cordless Drill Phillips Screw Bit Two-step Drill Bit (3/8-1/8 ) Utility Knife Interior Mullion Exterior Mullion Cover Hardware Kit Clamps

More information

Assembly and Installation Instructions Section 1

Assembly and Installation Instructions Section 1 Assembly and Installation Instructions Section 1 March 2013 PART NO. YS57 EFCO 2012 Page 2 Series 5500 XTherm Curtain Wall Assembly and Installation Instructions SECTION Note: Installation Instructions

More information

Flushglaze For Framed Openings and Horizontal Panels. Window System Installation Guide

Flushglaze For Framed Openings and Horizontal Panels. Window System Installation Guide Flushglaze 4500 For Framed Openings and Horizontal Panels Window System Installation Guide January 2017 BENCHMRK Welcome to Kingspan, global leaders in the design and manufacture of insulated metal panels

More information

INSTALLATION INSTRUCTIONS FOR REPLACEMENT FORGENT WOOD GLASTRA WINDOWS RECOMMENDATIONS FOR COMMON INSTALLATION OF ALL REPLACEMENT WINDOWS.

INSTALLATION INSTRUCTIONS FOR REPLACEMENT FORGENT WOOD GLASTRA WINDOWS RECOMMENDATIONS FOR COMMON INSTALLATION OF ALL REPLACEMENT WINDOWS. INSTALLATION INSTRUCTIONS FOR REPLACEMENT FORGENT WOOD GLASTRA WINDOWS RECOMMENDATIONS FOR COMMON INSTALLATION OF ALL REPLACEMENT WINDOWS. Installer: DO NOT DISCARD Please leave the Installation Guide

More information

BuildingEnvelope Oldcastle ( ) -

BuildingEnvelope Oldcastle ( ) - BuildingEnvelope 1-866-Oldcastle (653-2278) - www.obe.com RELIANCE -LT CURTAIN WALL 2" X 7-1/2" / POLYAMIDE PRESSURE PLATE / 1" GLAZING Elev-Reliance-LT-750-PolyPP H0042-Steel-Anchor H5021-ShrBlk-Anchors

More information

RELIANCE CURTAIN WALL INSTALLATION AND GLAZING MANUAL

RELIANCE CURTAIN WALL INSTALLATION AND GLAZING MANUAL RELIANCE CURTAIN WALL INSTALLATION AND GLAZING MANUAL Note: The installation details found in this package are generic and are for representation only with the intent of giving the installation team a

More information

Steel Reinforced Joining Thank you for choosing Andersen. Please leave this guide with building owner.

Steel Reinforced Joining Thank you for choosing Andersen. Please leave this guide with building owner. Steel Reinforced Joining (Horizontal/Vertical) for Andersen 400 Series Woodwright & Tilt-Wash Double-Hung, Picture, and Transom Windows and 400 Series Double-Hung Half Circle and Flexiframe Specialty Windows

More information

SERIES 900 TERRACE DOOR WITH TRANSOM AND SIDELITES

SERIES 900 TERRACE DOOR WITH TRANSOM AND SIDELITES INSTALLATION INSTRUCTIONS SERIES 900 TERRACE DOOR WITH TRANSOM AND SIDELITES Phone: (800) 262-5151 Fax: (866) 262-3299 crlaurence.com usalum.com crl-arch.com 11M0172_REV_A HANDLING, STORAGE, AND PROTECTION

More information

Sliding Glass Door Assembly and Installation Guide

Sliding Glass Door Assembly and Installation Guide Sliding Glass Door Assembly and Installation Guide Index Door System Components and Hardware The following components are needed to complete the installation of your Sliding Patio Door unit. Check all

More information

Installation Guidelines For Quaker Window Products Aluminum flange fin sub sill & receptor system using a T mulled twin window unit.

Installation Guidelines For Quaker Window Products Aluminum flange fin sub sill & receptor system using a T mulled twin window unit. Installation Guidelines For Quaker Window Products Aluminum flange fin sub sill & receptor system using a T mulled twin window unit. Installer: Read these instructions completely before starting any installation.

More information

Read guide from beginning to end before starting installation. Read all warnings and cautions during unit installation.

Read guide from beginning to end before starting installation. Read all warnings and cautions during unit installation. Installation Guide for E-Series/Eagle High-Performance Mullion Windows with LVL Reinforcement and Installed Using Type B Clips Thank you for choosing Andersen. Instructions are for typical, new wood-framed

More information

4. Partially open the operating panel and tilt the top toward the interior of the door (Figure 4). Lift the panel off the sill and set it aside.

4. Partially open the operating panel and tilt the top toward the interior of the door (Figure 4). Lift the panel off the sill and set it aside. Effective Date: 10/1/2017 Tools Needed Kit Contents Hardware Kit Safety Glasses Cordless drill Phillips screw bit Two-step drill bit (3/8-1/8 ) utility knife Interior Mullion Exterior Mullion Cover clamps

More information

YVS 400 TU Window System

YVS 400 TU Window System YVS 400 TU SYSTEM DESCRIPTION YVS 400 TU PERFORMANCE FEATURES 4 Overall Depth ThermaBond Plus Poured & Debridged Thermal Break Variations: Single Hung, Double Hung & Fixed Windows 1 /8 & 1 1 /16 Glazing

More information

PIVOT DOOR 3400P INSTALLATION INSTRUCTIONS

PIVOT DOOR 3400P INSTALLATION INSTRUCTIONS Table of Contents I. Tools, Sealant Requirements, Anchor Recommended Table...1 II. Opening, Frame & Panel Verification...2-3 III. Frame Assembly...4 IV. Frame Installation...5-7 V. Glazing Instructions...8

More information

Transom Joining. for Andersen Elliptical Windows over Perma-Shield Gliding Patio Door

Transom Joining. for Andersen Elliptical Windows over Perma-Shield Gliding Patio Door Transom Joining for Andersen Elliptical Windows over Perma-Shield Gliding Patio Door INSTALLER: Please leave this guide with the building owner to file for future reference. Congratulations! You have just

More information

INSTALLATION INSTRUCTIONS IMPERVIA SLIDING PATIO DOOR WITH FINS

INSTALLATION INSTRUCTIONS IMPERVIA SLIDING PATIO DOOR WITH FINS 2008 Pella Corporation Part Number: 803V0101 INSTALLATION INSTRUCTIONS IMPERVIA SLIDING PATIO DOOR WITH FINS Installation Instructions for Typical Wood Frame Construction. These instructions were developed

More information

Installation Instructions for Vista Air Vertically Folding Walls

Installation Instructions for Vista Air Vertically Folding Walls Installation Instructions for Vista Air Vertically Folding Walls Use these instructions in conjunction with your shop drawings to see the specifics that are particular to the model you are installing.

More information

Curtain Wall Installation Guide

Curtain Wall Installation Guide Curtain Wall Installation Guide Curtain Wall Installation Guide 1 IMPORTANT NOTICES! Important Notices & Information Manufacturer s Notes: The building envelope must be correctly prepared with weather

More information

Pocket Door Installation Instructions

Pocket Door Installation Instructions Installation Instructions Before getting started: Read instructions thoroughly. Be sure that you have the necessary tools and materials before starting the installation. Consult your local building code

More information

YSD 600 T/TH Sliding Door System Installation Manual

YSD 600 T/TH Sliding Door System Installation Manual System Installation Manual 2006 YKK AP America Inc. is a subsidiary of YKK Corporation of America. TABLE OF CONTENTS Installation Notes........................................ Page ii & iii PARTS DESCRIPTION

More information