INSTALLATION INSTRUCTIONS. Thermal Entrances AA 250/AA 425 THERMAL DOOR WITH TRIFAB 601/601T FRAMING

Size: px
Start display at page:

Download "INSTALLATION INSTRUCTIONS. Thermal Entrances AA 250/AA 425 THERMAL DOOR WITH TRIFAB 601/601T FRAMING"

Transcription

1 JANUARY, INSTALLATION Thermal Entrances AA 250/AA 425 THERMAL DOOR WITH TRIFAB 601/601T FRAMING INSTRUCTIONS

2 2 FRAME ASSEMBLY JANUARY, SHEAR BLOCK BALL BEARING NRP BUTT (FACTORY APPLIED TO DOOR) HINGE REINF POCKET INSERT JAMB SEALANT SHEAR BLOCK (FACTORY APPLIED) x 9/16" F.H.M.S PVC Door Stop (Factory Applied to Jambs and Header) SHEAR BLOCK (FACTORY APPLIED) #10 x 1-19/32" P.H #10 x 9/16" F.H #10 x 1-19/32" P.H. 601CG001 HEADER #10 x 1" F.H GLASS STOPS TRANSOM BAR JAMB THRESHOLD CLIP (FACTORY APPLIED TO BOTH JAMBS) x 3/8" F.H.M.S BUTT HUNG x 5/8" F.H.M.S x 3/8" F.H.M.S x 1-3/4" F.H.M.S THRESHOLD CLIP (FACTORY APPLIED TO BOTH JAMBS) BOTTOM PIVOT (IN DOOR PKG.) OFFSET PIVOT

3 JANUARY, 2014 FRAME INSTALLATION 3 INSTALLATION OF ASSEMBLED FRAME 1. Check opening allowing enough shim space at top and sides so that frame may be plumbed and squared. 2. Set threshold in bed of sealant or mastic. 3. Shim and secure jambs and header in opening (Figure 1). 4. If pivot is not supported by the finished floor, grout or block under it as required. If door will be hung and operated prior to threshold or finished floor installation, block under pivot and anchor to floor with #12 FHMS. 5. Secure the threshold (if supplied) to the floor. GLAZE THE TRANSOM 1. Snap interior glass stop on to transom bar. Apply bead of sealant to base of front leg of the glass stop where it meets the top of the transom bar, or transom bar adapter. 2. Pre-cut horizontal and vertical push-on gasket allowing approximately 1/4" per foot extra. See (Figure 2) for transom area glass size. 3. Insert interior push-on gasket into glass stop and remaining 3 glazing pockets (vertical transom jambs and header). 4. Position glass into transom area and place setting blocks on the transom bar at 1/4 points. 5. Install remaining glass stop in the transom bar. Install exterior push-on gaskets into glazing pockets. CONTINUOUS PERIMETER SEAL 1/4" FASTENER SHIM DRILL 1/2" HOLE PLUG DIM. "A" CONTINUOUS PERIMETER SEAL GLAZE FRAME 1. Cut interior and exterior push-in gasket to an approximate length of 1/4" per foot extra. Install interior gasket in reglet (Figure 3). 2. Position glass in frame using standard flush glazing technique. Position setting blocks under glass and install glass stops. 3. Push exterior gasket into reglet (Figure 3). NOTE: Opening glazing joints is a major source of leakage. GLASS THICKNESS GLASS SIZE = DIM. "A" - 5/16" FIGURE 1 FIGURE 2 SETTING BLOCK GASKET (BOTH SIDES) FIGURE 3 GLASS SIZE DIM. "B" - 1/2" DIM. "B" 1" Gasket = Apporximately 1/4" per foot extra Horizontal Gasket runs through Start at ends and work towards center

4 4 DOOR INSTALLATION OVERHEAD CLOSERS OFFSET PIVOT SHOWN, BUTT HUNG SIMILAR JANUARY, 2014 FUTURE FINISHED FLOOR LINE When pivot is not resting on finished floor, shim with wood block as shown and anchor to sub-floor with a #12 F.H. Screw. See Frame Installation Instructions as required. #12 F.H. SCREW SUB-FLOOR 1. Place frame half of top pivot in position into transom bar and secure in place using (3) screws #12-24 x 5/8" M.S. 2. Set door in frame so that door portion of the bottom pivot engages spindle of frame portion of the pivot. 3. Depress pin in top door portion pivot and slip under frame portion until positive engagement is felt. FIGURE 4 ALLEN WRENCH CAP SCREW NOTE: The bottom pivot is pre-adjusted to provide 1/8" clearance between door top rail and frame transom bar. For further vertical adjustment, see FIGURE 4. Remove cap screw and insert allen wrench. Turn adjustment screw clockwise to raise door, counterclockwise to lower door. 4. When door is properly positioned, secure closer body to transom bar per instructions provided with closer. 5. Attach closer arm to door per following special instructions: a. Drill into top rail using #7 drill. (See closer instructions for hole locations). b. Tap holes in top rail for 1/4"-20 screws. SPECIAL ARM ATTACHMENT FOR SURFACE CLOSER TOP RAIL

5 JANUARY, ADJUSTABLE 4 SETTING BLOCK GLAZING INSTRUCTIONS NOTE: Glass sizes and size formulas for AA 250/AA 425 doors are the same as those for 190 doors (Door lite opening less 3/8"). GLASS JACK MOUNTING STUD TRUSS HEAD SCREW GLASS JACK 2 1. Raise adjustable setting block 4 to a maximum retracted position (Figure 5). 2. Install setting block at 1 and caps at 2,3 and 4. Setting block and caps found in glazing package (Figure 5). 3. Install glass in place, centered between stiles and tight against bottom rubber setting block (Figure 5). 4. Using thumb or tool, rotate glass jacks counterclockwise to set against glass (Figure 6). 5. Install vertical glass stops first, then horizontals. 6. Turn the adustable setting block screw clockwise and adjust for uniform clearance between top edge of door and frame. 7. Install push pull hardware. FIGURE 6 ADJUSTABLE SETTING BLOCK (On AA 250 Door Only) 6" GLASS JACK 1 SETTING BLOCK FIGURE 5 WEATHERING ADJUSTMENTS Interior Pile Weathering Exterior Pile Weathering CAP FOR DOUBLE GLAZING INSULATED GLASS BOTTOM OF THE DOOR ASTRAGAL WITH (2) PILE WEATHERING Remove packing string from pile after door installation. Swing door to partial open position so as to allow the rubber of the weathering strip to maintain continuous contact on the flat portion of the threshold (do not compress rubber). The weathering strip is not designed to act as a "sweep", yet when properly installed it must maintain contact with the raised lip of the threshold.

6 6 KAWNEER 1686 CONCEALED ROD EXIT DEVICE JANUARY, CONVERSION KIT PROCEDURE (1686 CONCEALED ROD EXIT DEVICE) IN ORDER TO MAKE THIS EXIT DEVICE FIT A AA 250/AA 425, 2-1/4" THERMAL DOOR, THE FOLLOWING CHANGES MUST TO BE MADE: THIS FASTENER IS USED TO MOUNT THE CYLINDER MOUNTING PAD. THE CYLINDER MOUNTING PAD MUST BE ORDERED SEPARATELY REMOVE THE TWO ORIGINAL FLAT HEAD SCREWS THAT SECURING THE NO. 3 SPACER. 2. TAKE THE NO. 2 LIFT PIN SPACER BRACKET FROM THE KIT AND PLACE IT BETWEEN THE NO. 1 CENTER ROD ASSEMBLY AND THE NO. 3 SPACER. USE THE TWO NO. 4 1/4"-20 X 3/4" SCREWS FROM THE KIT AND REASSEMBLE THESE PARTS AS SHOWN. 3. NOW THE ROD ASSEMBLY IS READY TO INSTALL INTO THE STILE. 4. INSTALL THE NO. 5 TOP GUIDE AND NO. 6 BOTTOM GUIDE BLOCKS FROM THE KIT USING THE NO. 7 SCREWS PROVIDED. 5. DISCARD THE ORIGINAL BLOCKS. 6. IN ORDER TO INSTALL THE CYLINDER MOUNTING PAD THE NO. 8 #8-32 X 2/7/16" FLAT HEAD SCREWS IN THIS KIT, WILL NEED TO BE USED. NOTE: Refer to Instruction # for 1686 Exit Device Installation. 6 7 THRESHOLD STOP APPLICATION (1686 CONCEALED ROD DEVICE) DRILL (2) 5/32"(.156) DIAMETER HOLES AND SECURE STOP WITH #10 SELF-TAP SCREWS C OF DOOR OPENING L 4" 1" 2" THRESHOLD STOP APPLICATION

7 JANUARY, 2014 RM-86 REMOVABLE MULLION INSTRUCTIONS For 1786 Rim Exit Device 7 REMOVABLE MULLION INSTALLATION LINE OF DOOR STOP 1. Attach shoe mullion mounting plate to header/t-bar as shown. 2. Attach top shoe mullion to mounting plate on header/t-bar as shown. "A" SHOE MULLION SECTION "A-A" TOP BRACKET "A" ATTACH MOUNTING PLATE TO T-BAR ATTACH SHOE MULLION TO MOUNTING PLATE (DOTTED) USE #21 DRILL AND PREP FOR #10 X 1"F.H. 7/8" 3. Secure bottom shoe mullion to floor as shown. 4. Check removable mullion for correct length from bottom of mullion to centerline of strike. a. Cut mullion to proper overall length if required. 5. Slip removable mullion into top shoe mullion, pick up and swing onto bottom shoe mullion. 6. Install back plate onto shoe mullion at header/t-bar and threshold. (See Figure 7) 1/4" MOUNTING PLATE (SEE SECTION "A-A") SHOE MULLION BACK PLATE FOR SHOE MULLION AT T-BAR BACK PLATE FOR SHOE MULLION AT THRESHOLD MULLION STABILIZER SHOE MULLION FRAME OPENING MINUS 1-9/16" 11/16" (WITH OR WITHOUT THRESHOLD) WITHOUT THRESHOLD 11/16" 40" TO BOTTOM OF DOOR "B" WITH THRESHOLD FIGURE 7 "B" 5/8" 1" LINE OF DOOR STOP 1-1/2" 7/16" EXTERIOR C OF DOOR OPENING L 1-5/16" 21/32" SECTION "B-B" (BOTTOM BRACKET) PREP FOR #10 F.H. 1-1/8" 3/8"

8 8 JANUARY, 2014 MULLION STABILIZER INSTALLATION 1. Attach frame portion stabilizers in holes provided on mullion with 2 ea. #10-24 x 7/8" O.H.M.S. 2. Close door and align door portion on the door, allowing 1/16" for clearance, as shown. 3. Mark hole centers, drill and tap for #10-24 in door. 4. Attach door portion stabilizers to door with 2 ea. #10-24 x 7/8" O.H.M.S. REMOVABLE MULLION FRAME PORTION STABILIZER DOOR PORTION STABILIZER #10-24 x 7/8" O.H.M.S. 1/16" KAWNEER 1786 RIM EXIT DEVICE (Refer to Instruction # for 1786 Exit Device Installation)

9 JANUARY, TRIM CAP INSTALLATION INTO THERMAL PVC DOOR STOP 1. Starting at the top of vertical door jamb member, begin by installing the vertical aluminum jamb trim cap into the PVC door stop jamb member. 2. Insert the trim cap radius tail piece into the notch directly located on interior side of PVC door stop fin. 3. Using a rubber mallet be very careful not to scratch or dent the aluminum trim cap during installation. 4. Gently tap the trim cap with rubber mallet, until part engages the PVC door stop. 5. Continue this application, from top to bottom on both vertical PVC door stop jamb members. 6. Repeat the same process when applying the aluminum trim cap on the transom/header member. Insert the trim cap radius tail piece into the notch. Gently tap the trim cap with rubber mallet. Field sealing door stop cavity due to hardware preps in jamb or transom/header. When hardware preps require the removable of PVC door stop fin and aluminum trim cap, field installer must fill cavity with sealant to match finish. Fill cavity with sealant to match finish. Fill cavity with sealant to match finish.

10 10 JANUARY, 2014 KAWNEER COMPANY, INC. 555 GUTHRIDGE COURT NORCROSS, GA 30092

Swing Door Installation Manual

Swing Door Installation Manual Manual 20D/35D/50D 20DH/35DH 40M/50M 25FD 35XT 50XT 01-4000-03 2010 YKK AP America Inc. is a subsidiary of YKK Corporation of America. TABLE OF CONTENTS Installation Notes.......................................

More information

Heavy Wall Applied Stop Tube Frame and Door Installation

Heavy Wall Applied Stop Tube Frame and Door Installation INSTALLATION INSTRUCTIONS Heavy Wall Applied Stop Tube Frame and Door Installation Read all instructions before beginning installation. These instructions are provided to help prevent installation problems

More information

Storefront Installation Guide INSTALLATION INSTRUCTIONS

Storefront Installation Guide INSTALLATION INSTRUCTIONS STOREFRONT General Notes 1. Check contract documents and shop drawings, and understand and clarify any Field Verify Notes, approvals of drawings, and products required to be familiar with the project.

More information

For installation assistance, contact SARGENT at DOORS SHOWN HERE SWING IN FOR ILLUSTRATION PURPOSES ONLY.

For installation assistance, contact SARGENT at DOORS SHOWN HERE SWING IN FOR ILLUSTRATION PURPOSES ONLY. SARGENT Installation Instructions for LP8600 x LR8600 & 12-LP8600 x 12-LR8600 Series Low Profile Panic and Fire Exit Devices on Double Egress & Double Doors or LS8600 & 12-LS8600 Low Profile Exit Device

More information

NARROW, MEDIUM AND WIDE STILE, THERMASTILE AND DURASTILE. Installation Instructions

NARROW, MEDIUM AND WIDE STILE, THERMASTILE AND DURASTILE. Installation Instructions NARROW, MEDIUM AND WIDE STILE, THERMASTILE AND DURASTILE Installation Instructions PART Y015 JUNE 2016 Table of Contents Section 1. GENERAL NOTES AND GUIDELINES... 2. DOOR HARDWARE A. Locks B. Push/Pulls

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS Thermally Broken Framing and Door Installation SL-450TB (2" x 4-1/2" with 1" Glazing) & SL-600TB (2" x 6" with 1" Glazing) IMPORTANT: Read all instructions before beginning installation.

More information

Thermally Broken Framing and Door Installation

Thermally Broken Framing and Door Installation INSTALLATION INSTRUCTIONS Thermally Broken Framing and Door Installation IMPORTANT: Read all instructions before beginning installation. These instructions are provided to help prevent installation problems

More information

Heavy Wall Applied Stop Tube Frame and Door Installation

Heavy Wall Applied Stop Tube Frame and Door Installation INSTALLATION INSTRUCTIONS Heavy Wall Applied Stop Tube Frame and Door Installation IMPORTANT: Read all instructions before beginning installation. These instructions are provided to help prevent installation

More information

CONCEALED VERTICAL ROD PANIC EXIT DEVICE

CONCEALED VERTICAL ROD PANIC EXIT DEVICE INSTALLATION INSTRUCTIONS CRL JACKSON 1085-1085P CONCEALED VERTICAL ROD PANIC EXIT DEVICE crlaurence.com Phone: (800) 421-6144 Fax: (866) 921-0531 crlaurence.com usalum.com crl-arch.com 11M0236 ORDER OF

More information

4-lite Patio Door. Installation Instructions

4-lite Patio Door. Installation Instructions 4-lite Patio Door Installation Instructions IMPORTANT: Read the instructions and familiarize yourself with the door parts and pieces before beginning assembly and installation. Note: Only the 5-0 x 6-8

More information

C-Series & S-Series Classic Frame with Transom (Single or Pair)

C-Series & S-Series Classic Frame with Transom (Single or Pair) 1. TOOLS REQUIRED Tape measure 6' magnetic level 3' magnetic level Safety Glasses Screw gun #2 Screwdriver tip #3 Screwdriver tip Philips Head screwdriver (Used to move frame on wall using oval slots on

More information

YSD 400 Sliding Door System Installation Manual

YSD 400 Sliding Door System Installation Manual System Installation Manual 2006 YKK AP America Inc. is a subsidiary of YKK Corporation of America. TABLE OF CONTENTS Installation Notes........................................ Page ii PARTS DESCRIPTION

More information

Vinyl Sliding Glass Door Assembly Instructions

Vinyl Sliding Glass Door Assembly Instructions Vinyl Sliding Glass Door Assembly Instructions SERIES SGD 5470/5570 Para instrucciones en español, visite: http://bit.ly/pgtassemblyinstructions Parts List ITEM 4 5 6 7 8 9 0 4 5 6 7 8 SGD 5470/5570 PARTS

More information

Sliding Glass Door Assembly and Installation Guide

Sliding Glass Door Assembly and Installation Guide Sliding Glass Door Assembly and Installation Guide Index Door System Components and Hardware The following components are needed to complete the installation of your Sliding Patio Door unit. Check all

More information

YES 600 Thermal Clip Storefront System Installation Manual

YES 600 Thermal Clip Storefront System Installation Manual Installation Manual 2004 YKK AP America Inc. is a subsidiary of YKK Corporation of America. TABLE OF CONTENTS Installation Notes........................................ Page ii Frame Types............................................

More information

3-LITE PATIO DOOR INSTALLATION INSTRUCTIONS

3-LITE PATIO DOOR INSTALLATION INSTRUCTIONS 3-LITE PATIO DOOR INSTALLATION INSTRUCTIONS IMPORTANT: Read the instructions and familiarize yourself with the door parts and pieces before beginning assembly and installation. TOOLS NEEDED: Tape Measure

More information

INSTALLATION INSTRUCTIONS Frames and Entrance Doors

INSTALLATION INSTRUCTIONS Frames and Entrance Doors INSTALLATION INSTRUCTIONS Frames and Entrance Doors J 3010 Rice Mine Road, Tuscaloosa, Alabama 35406 1-800-772-7737 Fax 1-800-443-6261 www.coralind.com A Division of Coral Industries, Inc. FRAMES and ENTRANCES

More information

1790 Touchbar. Installation Instructions. Rim Panic Device ININST Index:

1790 Touchbar. Installation Instructions. Rim Panic Device ININST Index: Installation Instructions ININST.1001 1790 Touchbar Rim Panic Device Index: Before Installation... 2 Installation... 2 Touchbar Dogging... 7 RM170 Mullion Installation... 8 Field Sizing Device... 10 2090

More information

PIVOT DOOR 3400P INSTALLATION INSTRUCTIONS

PIVOT DOOR 3400P INSTALLATION INSTRUCTIONS Table of Contents I. Tools, Sealant Requirements, Anchor Recommended Table...1 II. Opening, Frame & Panel Verification...2-3 III. Frame Assembly...4 IV. Frame Installation...5-7 V. Glazing Instructions...8

More information

INSTALLATION INSTRUCTIONS CRL JACKSON

INSTALLATION INSTRUCTIONS CRL JACKSON INSTALLATION INSTRUCTIONS CRL JACKSON 3185 MID-PANEL CONCEALED VERTICAL ROD PANIC EXIT DEVICE crlaurence.com Phone: (800) 421-6144 Fax: (866) 921-0531 crlaurence.com usalum.com crl-arch.com 11M0252 ORDER

More information

350/500 HEAVY WALL TM IR ENTRANCES 1

350/500 HEAVY WALL TM IR ENTRANCES 1 JUNE, 202 30/00 HEAVY WALL TM IR ENTRANCES FEATURES Blast Mitigation Product Features 30 medium stile has 3-/2" vertical stile, 3-/2" top and 6-/2" bottom rail 00 wide stile has " vertical stile, " top

More information

INSTALLATION INSTRUCTIONS CRL JACKSON

INSTALLATION INSTRUCTIONS CRL JACKSON INSTALLATION INSTRUCTIONS CRL JACKSON 2085 CONCEALED VERTICAL ROD PANIC EXIT DEVICE crlaurence.com Phone: (800) 421-6144 Fax: (866) 921-0531 crlaurence.com usalum.com crl-arch.com 11M0250 ORDER OF ASSEMBLY

More information

Safety glasses Measuring tape Level Pencil Power drill Center punch Phillips screw driver Saw horse

Safety glasses Measuring tape Level Pencil Power drill Center punch Phillips screw driver Saw horse EX76 Concealed Vertical Rod Exit Device Preparation Guide and Installation Instructions Box Contents EX76 Concealed Vertical Rod Exit Device Back Bar Active Push Bar Filler Plate Door Kit with Templates

More information

YCW 750 IG Inside Glazed Curtain Wall System Installation Manual

YCW 750 IG Inside Glazed Curtain Wall System Installation Manual Installation Manual 2014 YKK AP America Inc. is a subsidiary of YKK Corporation of America. TABLE OF CONTENTS Installation Notes... Page ii PARTS DESCRIPTION YCW 750 IG Framing Members... Page 1 to 3

More information

YCW 752 Outside Glazed Curtain Wall System Installation Manual

YCW 752 Outside Glazed Curtain Wall System Installation Manual YCW 752 Outside Glazed Curtain Wall System Installation Manual 2007 YKK AP America Inc. is a subsidiary of YKK Corporation of America. TABLE OF CONTENTS Installation Notes........................................

More information

350/500 Heavy Wall TM IR Entrances

350/500 Heavy Wall TM IR Entrances SEPTEMBER, 207 FEATURES Hurricane Resistant Product Blast Mitigation Product Features 50 Heavy Wall TM IR medium stile has vertical stiles, top and 6-/ (65.) bottom rails 500 Heavy Wall TM IR wide stile

More information

YHS 50 FS Storefront System & Model 35H/50H Door Installation Manual

YHS 50 FS Storefront System & Model 35H/50H Door Installation Manual Installation Manual 2014 YKK AP America Inc. is a subsidiary of YKK Corporation of America. TABLE OF CONTENTS Installation Notes... Page ii PARTS DESCRIPTION YHS 50 Framing Members... Page 1 YHS 50 Accessories...

More information

Installation Instructions for Vista Air Vertically Folding Walls

Installation Instructions for Vista Air Vertically Folding Walls Installation Instructions for Vista Air Vertically Folding Walls Use these instructions in conjunction with your shop drawings to see the specifics that are particular to the model you are installing.

More information

FIRE RATED DOOR AND FRAME GENERAL REQUIREMENTS

FIRE RATED DOOR AND FRAME GENERAL REQUIREMENTS FIRE RATED DOOR AND FRAME GENERAL REQUIREMENTS These requirements apply to all fire rated doors, frames, and windows. Requirements for the installation of these assemblies are included in the Standard

More information

SLIDING GLASS DOOR ASSEMBLY INSTRUCTION Series 680/780

SLIDING GLASS DOOR ASSEMBLY INSTRUCTION Series 680/780 10/07 M0200030 GENERAL NOTICE READING THESE INSTRUCTIONS FIRST AND FOLLOWING THE PROCEDURES IN PROPER SEQUENCE WILL REDUCE FRUSTRATION, COSTLY MISTAKES AND WASTED TIME. Protect main frame only with light

More information

INSTALLATION INSTRUCTIONS CRL JACKSON

INSTALLATION INSTRUCTIONS CRL JACKSON INSTALLATION INSTRUCTIONS CRL JACKSON 1285 CONCEALED VERTICAL ROD PANIC EXIT DEVICE crlaurence.com Phone: (800) 421-6144 Fax: (866) 921-0531 crlaurence.com usalum.com crl-arch.com 11M0248 ORDER OF ASSEMBLY

More information

Fold-A-Way Patio Door ASSEMBLY & INSTALLATION GUIDE

Fold-A-Way Patio Door ASSEMBLY & INSTALLATION GUIDE Fold-A-Way Patio Door ASSEMBLY & INSTALLATION GUIDE This instruction guide provides the minimum recommended procedures to correctly prepare the rough opening, install a fold-a-way patio door unit and apply

More information

350/500 IR Entrances. Features

350/500 IR Entrances. Features OCTOBER, 05 Features FEATURES Blast Mitigation Product 50 IR medium stile has vertical stiles, top and 6-/" (65.) bottom rails 500 IR wide stile has (7) vertical stile, (7) top and 6-/" (65.) bottom rail.

More information

350/500 IR Entrances. Features

350/500 IR Entrances. Features SEPTEMBER, 07 Features FEATURES Blast Mitigation Product 50 IR medium stile has vertical stiles, top and 6-/" (65.) bottom rails 500 IR wide stile has (7) vertical stile, (7) top and 6-/" (65.) bottom

More information

4600 Series Rim Narrow Stile Exit Device Installation Instructions I-ED01162

4600 Series Rim Narrow Stile Exit Device Installation Instructions I-ED01162 DEVICES COVERED IN THIS DOCUMENT: 4600 Series Rim Panic Narrow Stile Exit Device 4600 Series Rim Fire Narrow Stile Exit Device OVERVIEW Outside of Door RHR LHR Inside of Door APPLICATIONS 4950 BLADE STOP

More information

TOOLS REQUIRED Metal Wood Wood and Metal Screws. #16 Drill #12-24 Tap. 1/8 Drill

TOOLS REQUIRED Metal Wood Wood and Metal Screws. #16 Drill #12-24 Tap. 1/8 Drill DEVICES COVERED IN THIS DOCUMENT: 4700S Surface Vertical Rod Device 4700SF Fire Exit Surface Vertical Rod Device TOOLS REQUIRED Metal Wood Wood and Metal Screws Sex Bolts #7 Drill ¼ -20 Tap #16 Drill #12-24

More information

FIRE RATED DOOR AND FRAME GENERAL REQUIREMENTS

FIRE RATED DOOR AND FRAME GENERAL REQUIREMENTS ` FIRE RATED DOOR AND FRAME GENERAL REQUIREMENTS These requirements apply to all fire rated doors, frames, and windows. Requirements for the installation of these assemblies are included in the Standard

More information

YSD 600 T/TH Sliding Door System Installation Manual

YSD 600 T/TH Sliding Door System Installation Manual System Installation Manual 2006 YKK AP America Inc. is a subsidiary of YKK Corporation of America. TABLE OF CONTENTS Installation Notes........................................ Page ii & iii PARTS DESCRIPTION

More information

4500 Series. Fabrication and Installation Instructions

4500 Series. Fabrication and Installation Instructions 4500 Series Fabrication and Installation Instructions E4500 Series July, 2017 Table of Contents GENERAL CONSTRUCTION NOTES... 3 EXTRUDED ALUMINUM PARTS... 5 ACCESSORIES... 7 OVERVIEW... 8 FRAME FABRICATION...

More information

14000 Series. Fabrication and Installation Instructions

14000 Series. Fabrication and Installation Instructions 14000 Series Fabrication and Installation Instructions Revision May 2013 Table of Contents GENERAL CONSTRUCTION NOTES...3 EXTRUDED ALUMINUM PARTS...5 ACCESSORIES...8 OVERVIEW...10 FRAME FABRICATION...15

More information

ELEPHANT DOOR SYSTEMS SERIES E1200

ELEPHANT DOOR SYSTEMS SERIES E1200 INSTALLATION INSTRUCTIONS ELEPHANT DOOR SYSTEMS SERIES E1200 Phone: (800) 262-5151 Fax: (866) 262-3299 crlaurence.com usalum.com crl-arch.com AVDB3096 03.13 TABLE OF CONTENTS SUBJECT PAGE GENERAL INSTALLATION

More information

350 IR ENTRANCES INDEX

350 IR ENTRANCES INDEX 50 IR ENTRANCES INDEX Hurricane Resistant Product PICTORIAL VIEW... IR 500 ENTRANCE FRAMING DETAILS... 4 IR 50 ENTRANCE FRAMING DETAILS... 5 TRIFAB VG 450 FRAMES / 600 WALL SUB-FRAMES...6 INFILL OPTIONS

More information

FLUSHLINE ENTRANCES. Features

FLUSHLINE ENTRANCES. Features OCTOBER, 2006 FLUSHLINE ENTRANCES FEATURES 1 Features Flush appearance with a face sheet of fiberglass reinforced polyester (FRP) or aluminum, that is captured on four sides by integral extruded reglets

More information

Atrium Patio Door Field Service Manual

Atrium Patio Door Field Service Manual Atrium Patio Door Field Service Manual December 2005 Table of contents Service Agreement Pg 2 Release Agreement Pg 5 Inspection form Pg 6 Warranty Pg 8 Replacing swing panel Pg 12 Replacing sliding panel

More information

YES 40 FS/FI Storefront System Installation Manual

YES 40 FS/FI Storefront System Installation Manual Installation Manual 2014 YKK AP America Inc. is a subsidiary of YKK Corporation of America. TABLE OF CONTENTS Installation Notes... Page ii PARTS DESCRIPTION YES 40 FS Framing Members... Page 1 YES 40

More information

YCW 750 OG Outside Glazed Curtain Wall System Installation Manual

YCW 750 OG Outside Glazed Curtain Wall System Installation Manual YCW 750 OG Outside Glazed Curtain Wall System Installation Manual 2004 YKK AP America Inc. is a subsidiary of YKK Corporation of America. TABLE OF CONTENTS Installation Notes........................................

More information

Installation Manual. YSD 600 T/TH Sliding Door. YSD 600 T/TH Sliding Door System

Installation Manual. YSD 600 T/TH Sliding Door. YSD 600 T/TH Sliding Door System YSD 600 T/TH Sliding Door System Installation Manual 2014 YKK AP America Inc. is a subsidiary of YKK Corporation of America. TABLE OF CONTENTS Installation Notes... Page ii & iii PARTS DESCRIPTION Framing

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS BUILDERS CHOICE FRAMED Shower Height Swing Door Model: L533 Rev. 09.03.13 MAINTENANCE: Two primary materials are used to manufacture your new Aquatic enclosure; tempered glass

More information

I n s t a l l a t i o n I n s t r u c t i o n s S E N T I N E L S E R I E S 1 50 SLIDING GLASS DOORS

I n s t a l l a t i o n I n s t r u c t i o n s S E N T I N E L S E R I E S 1 50 SLIDING GLASS DOORS I n s t a l l a t i o n I n s t r u c t i o n s S E N T I N E L S E R I E S 1 50 SLIDING GLASS DOORS Page 2-9: Installation Instructions, Figures 1, 2, & 3 Page 10-12: Figures A-1, A-2, & A-3: Installation

More information

Superior by Design. Approved for use in Miami-Dade HVHZ Zones Florida Building Code Approved Product Approval FL FOLDING SLIDING STACKING PIVOT

Superior by Design. Approved for use in Miami-Dade HVHZ Zones Florida Building Code Approved Product Approval FL FOLDING SLIDING STACKING PIVOT Superior by Design. Euro PIVOT Door INSTALLATION GUIDE Approved for use in Miami-Dade HVHZ Zones Florida Building Code Approved Product Approval FL 22410 www.euro-wall.com 888.989.EURO (3876) FOLDING SLIDING

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS MARCH, 2009 PART NUMBER 590-500 1 INSTALLATION INSTRUCTIONS 2 INDEX MARCH, 2009 INSTALLATION INSTRUCTIONS CONTENTS These instructions show the general installation sequence and procedure for typical installation.

More information

YWE 40 T Window Wall System Installation Manual

YWE 40 T Window Wall System Installation Manual Installation Manual 2005 YKK AP America Inc. is a subsidiary of YKK Corporation of America. TABLE OF CONTENTS Installation Notes........................................ Page ii Frame Types............................................

More information

ED1300/1300F SERIES CONCEALED VERTICAL ROD DEVICE INSTALLATION INSTRUCTIONS

ED1300/1300F SERIES CONCEALED VERTICAL ROD DEVICE INSTALLATION INSTRUCTIONS ED1300/1300F SERIES CONCEALED VERTICAL ROD DEVICE INSTALLATION INSTRUCTIONS Ver.2 1300 SERIES CONCEALED VERTICAL ROD DEVICE Top Strike Latch Screws Strike Screws Release Plunger Top Latch Plunger Screws

More information

2300 BI-FOLD INSTALLATION GUIDE

2300 BI-FOLD INSTALLATION GUIDE 2300 BI-FOLD INSTALLATION GUIDE INSTALLATION INSTRUCTIONS OF MAIN FRAME Header #8 x 2½ zinc coated screws 2 1 2 Jamb Jamb 1 1 3 #8 x 2½ zinc coated screws 4 1 4 3 #8 x 2½ zinc coated screws 5 Threshold

More information

WOOD AND CLAD COMMERCIAL DOOR WOOD AND CLAD 2 1/4 COMMERCIAL DOOR. Table of Contents

WOOD AND CLAD COMMERCIAL DOOR WOOD AND CLAD 2 1/4 COMMERCIAL DOOR. Table of Contents WOOD AND CLAD COMMERCIAL DOOR WOOD AND CLAD 2 1/4 COMMERCIAL DOOR Table of Contents PAGE History... 2 Part Identification Wood Commercial Door XX RHRA... 3 Part Identification Wood Commercial Door Stationary

More information

14000 I/O Series Flush Glaze. Fabrication and Installation Instructions

14000 I/O Series Flush Glaze. Fabrication and Installation Instructions 14000 I/O Series Flush Glaze Fabrication and Installation Instructions Last saved on 12/18/2009 Table of Contents GENERAL CONSTRUCTION NOTES...3 EXTRUDED ALUMINUM PARTS...4 ACCESSORIES...5 OVERVIEW...6

More information

YHS 50 TU Storefront System & Model 35H Door Installation Manual

YHS 50 TU Storefront System & Model 35H Door Installation Manual Installation Manual 2012 YKK AP America Inc. is a subsidiary of YKK Corporation of America. TABLE OF CONTENTS Installation Notes... Page ii PARTS DESCRIPTION YHS 50 TU Framing Members... Page 1 YHS 50

More information

14000 Series. Fabrication and Installation Instructions

14000 Series. Fabrication and Installation Instructions 14000 Series Fabrication and Installation Instructions 14000 Series Revision December 01, 2009 Table of Contents GENERAL CONSTRUCTION NOTES... 3 EXTRUDED ALUMINUM PARTS... 4 ACCESSORIES... 7 OVERVIEW...

More information

YES 45 TU Thermal Storefront System Installation Manual

YES 45 TU Thermal Storefront System Installation Manual Installation Manual 2004 YKK AP America Inc. is a subsidiary of YKK Corporation of America. TABLE OF CONTENTS Installation Notes........................................ Page ii PARTS DESCRIPTION Framing

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS TOOLS REQUIRED Rechargeable, variable speed drill 3/8 diameter drill bit 3 Robertson bits #0, #1 and #2 Slot screwdriver Non marring hammer with 1 head Level Caulk or sealant

More information

Senior Swing. Caution

Senior Swing. Caution *740132* 740132 2800 Overhead Concealed Series 9500 Surface Applied Series Senior Swing Installation Instructions Caution LCN Senior Swing The Senior Swing Power Operator System is a low energy product

More information

INSTALLATION INSTRUCTIONS TRIFAB 451UT SCREW SPLINE ASSEMBLY TRIFAB 451UT. AUGUST, 2010 (Part No. 452T-CG-970) EC

INSTALLATION INSTRUCTIONS TRIFAB 451UT SCREW SPLINE ASSEMBLY TRIFAB 451UT. AUGUST, 2010 (Part No. 452T-CG-970) EC AUGUST, 2010 (Part No. 452T-CG-970) EC 97904-31 1 INSTALLATION SCREW SPLINE ASSEMBLY Kawneer Company, Inc., 2010 INSTRUCTIONS 2 TABLE OF CONTENTS (452T-CG-970) AUGUST, 2010 These instructions show the

More information

Storefront Installation Guide

Storefront Installation Guide Storefront General Notes: 1. Check Contract Documents and Shop Drawings. Understand and clarify any Field Verify Notes and approvals of drawings and products to be familiar with the project. Installation

More information

Knock Down Patio Door Assembly Instructions Regular & Impact

Knock Down Patio Door Assembly Instructions Regular & Impact Knock Down Patio Door Assembly Instructions Regular & Impact 72 x 80 72 x 82 72 x 96 96 x 80 96 x 82 96 x 96 Impress the Weather KD Patio Door Regular & Impact Sizes 72 x 80 72 x 82 72 x 96 96 x 80 96

More information

INSTALLATION INSTRUCTIONS TRIFAB VG SCREW SPLINE ASSEMBLY TRIFAB VG 450 TRIFAB VG 451 TRIFAB VG 451T

INSTALLATION INSTRUCTIONS TRIFAB VG SCREW SPLINE ASSEMBLY TRIFAB VG 450 TRIFAB VG 451 TRIFAB VG 451T INSTALLATION TRIFAB VG SCREW SPLINE ASSEMBLY TRIFAB VG 450 TRIFAB VG 451 TRIFAB VG 451T INSTRUCTIONS LITHO IN U.S.A. JANUARY KAWNEER COMPANY, INC., 2004 451-VG-970.01.04a PART NO. 451-VG-970 1 INSTALLATION

More information

Versatrim Side-Snap Frame

Versatrim Side-Snap Frame Versatrim Side-Snap Frame net door width finished opening width rough opening width (finished opening width plus 1 1/2") Figure 1 Cross section of strike and hinge jambs The rough opening width is equal

More information

Frameless Inline Door With Return QCI5263

Frameless Inline Door With Return QCI5263 INSTALLATION INSTRUCTIONS Frameless Inline Door With Return QCI5263 WALL MOUNT HINGES FRAMELESS DOOR / PANEL / RETURN PANEL QCI5263 REV. 0 Page 1 Certified 06/17/2016 Parts List with wall mount hinges

More information

YES 45 XT High Performance Thermal Storefront System

YES 45 XT High Performance Thermal Storefront System Dual Thermal Barrier ThermaBond Plus Pour & Debridge Technology Installation Manual 2015 YKK AP America Inc. is a subsidiary of YKK Corporation of America. TABLE OF CONTENTS Installation Notes... Page

More information

SECTION A4...IMPACT RATED ENTRANCES* 350 IR/500 IR ENTRANCES ENTRANCE HARDWARE OFFERINGS... A4/5

SECTION A4...IMPACT RATED ENTRANCES* 350 IR/500 IR ENTRANCES ENTRANCE HARDWARE OFFERINGS... A4/5 CONTENTS SECTION A4...IMPACT RATED ENTRANCES* Impact Rated Entrances CONTENTS PAGE FINISH GROUPS... A4/3 350 IR/500 IR ENTRANCES ENTRANCE HARDWARE OFFERINGS... A4/5 A4/1 350 IR/500 IR BASE DOOR DOOR CHASSIS...

More information

IDP Entry-Fit Steel Door Frames. Installation Instructions K2A and NK2A Series Frames

IDP Entry-Fit Steel Door Frames. Installation Instructions K2A and NK2A Series Frames IDP Entry-Fit Steel Door Frames Installation Instructions K2A and NK2A Series Frames IDP Inc 21300 W. 8 Mile Rd. Southfield, MI 48075 1-877-645-2770 www.idpframes.com email: info@idpframes.com K2A and

More information

series 9500 top load bi4fold installation instructions

series 9500 top load bi4fold installation instructions instructions Head Deflection (+0.12 / -0.00 ) Right Jamb Note: This is a top hung product. Provide adequate structure at head. Continuous threshold support is required. Left Jamb Head 4Lay bed of sealant

More information

UNIT No FRAMELESS PIVOT SHOWER DOOR

UNIT No FRAMELESS PIVOT SHOWER DOOR INSTALLATION INSTRUCTIONS UNIT No. 3600 FRAMELESS PIVOT SHOWER DOOR NEED INSTALLATION HELP? Call 1-800-45-BASCO (452-2726) Monday - Friday 8:00 A.M. - 4:30 P.M. Eastern Time QCI0020 Rev. 3 Page 1 of 8

More information

Metal Sound Retardant Door Hardware Information Bulletin

Metal Sound Retardant Door Hardware Information Bulletin 574 West Otterman Street Greensburg, PA 15601 Toll Free: (800) 979-7300 Local: (724) 834-7300 Fax: (724) 830-2871 Email: overly@overly.com DOOR COMPANY Metal Sound Retardant Door Hardware Information Bulletin

More information

Phone # La Jolla Doors. Block Frame Installation Manual Aluminum Frame with either Vinyl or Aluminum Panels

Phone # La Jolla Doors. Block Frame Installation Manual Aluminum Frame with either Vinyl or Aluminum Panels Phone # 800-440-8785 www.lajolladoors.com La Jolla Doors Block Frame Installation Manual Aluminum Frame with either Vinyl or Aluminum Panels Thank you for choosing La Jolla Doors In this manual you will

More information

Owner s Maintenance Section

Owner s Maintenance Section Owner s Maintenance Section Table of Contents Heavy Duty 1. Arm Loosening 2. Weather Changes & Closing Speed Adjustments 3. Door Out of Plumb Offset 4. Door Out of Plumb Center Hung 5. Door Sagging Vertical

More information

PRODUCT DATA CATALOG

PRODUCT DATA CATALOG PRODUCT DATA CATALOG CONTENTS PAGE STANDARD ELEVATIONS 2 STANDARD ELEVATIONS 3 DOOR SPECIFICATIONS 4 LOUVER SPECIFICATIONS 5 GLAZING SPECIFICATIONS 5 DOOR HANDING CHART 6 CLINE STANDARD HARDWARE LOCATIONS

More information

Retractable Screen Installation Instructions For Vinyl and Aluminum Clad and Wood In-Swing Hinged Doors (See separate instructions for sliding doors)

Retractable Screen Installation Instructions For Vinyl and Aluminum Clad and Wood In-Swing Hinged Doors (See separate instructions for sliding doors) Retractable Screen Installation Instructions For Vinyl and Aluminum Clad and Wood In-Swing Hinged Doors (See separate instructions for sliding doors) IMPORTANT: Please read before you begin. Table of Contents

More information

GENERAL INSTALLATION GUIDELINES

GENERAL INSTALLATION GUIDELINES 1551 MT. ROSE AVENUE YORK PA 17403-2909 (717) 849-8100 GENERAL INSTALLATION GUIDELINES For Receptor Systems Approved 08/31/2018 Installation Guideline Disclaimer This document contains general installation

More information

Instructions for the installation of Ellison Bronze balanced door models #137 & 138

Instructions for the installation of Ellison Bronze balanced door models #137 & 138 1. A packing list will be found in crate No. 1 of each shipment. The parts in the crates should be checked with this list. If there is any discrepancy, notify Ellison Bronze at once. 2. All parts are numbered.

More information

InSTallaTIon InSTruCTIonS For 4-lITe PaTIo Door unassembled

InSTallaTIon InSTruCTIonS For 4-lITe PaTIo Door unassembled InSTallaTIon InSTruCTIonS For 4-lITe PaTIo Door unassembled Measuring Tape Pencil Shims Drill & Drill bits: 6", 8", 5 6", 7 6" Tools & materials You Will need: Square Hammer or Mallet Level Stiff Putty

More information

CONTENTS. Custom Entrances and Hardware

CONTENTS. Custom Entrances and Hardware CONTENTS A2/1 CONTENTS SECTION A2...CUSTOM ENTRANCES AND HARDWARE* PAGE PRICING EXAMPLES... A2/3 A2/4 190/350/500 BASE DOOR DOOR CHASSIS... A2/5 DOOR GLAZING/WEATHERING OPTIONS... A2/6 DOOR BOTTOM RAIL

More information

Series 7600 Installation Instructions Aluminum Multi-Slide Door (Pocketing)

Series 7600 Installation Instructions Aluminum Multi-Slide Door (Pocketing) Series 7600 Installation Instructions Aluminum Multi-Slide Door (Pocketing) Things to Know Before You Start Things to Know Before You Start Removal of Old Fenestration Products Ensure any old fenestration

More information

INOVO 2-LITE SLIDING PATIO DOOR

INOVO 2-LITE SLIDING PATIO DOOR INOVO 2-LITE SLIDING PATIO DOOR ASSEMBLY AND INSTALLATION INSTRUCTIONS IMPORTANT: READ THE INSTRUCTIONS AND FAMILIARIZE YOURSELF WITH THE DOOR PARTS AND PIECES BEFORE BEGINNING ASSEMBLY AND INSTALLATION.

More information

Curtain Wall Installation Guide

Curtain Wall Installation Guide Curtain Wall Installation Guide Curtain Wall Installation Guide 1 IMPORTANT NOTICES! Important Notices & Information Manufacturer s Notes: The building envelope must be correctly prepared with weather

More information

FINISH GROUPS #17 GRP #17 CLEAR

FINISH GROUPS #17 GRP #17 CLEAR EFFECTIVE FEBRUARY 1, 2018 CONTENTS A3/1 CONTENTS SECTION A3...DOOR CLOSERS PAGE SURFACE MOUNTED CLOSERS... A3/2 A3/3 CALIBRE TM CLOSERS... A3/4 INTERNATIONAL CONCEALED CLOSERS... A3/5 CONCEALED CLOSER

More information

1200 SERIES 2 PANEL DOOR rev.1 DETAILED INSTALLATION INTRUCTIONS

1200 SERIES 2 PANEL DOOR rev.1 DETAILED INSTALLATION INTRUCTIONS 1200 SERIES 2 PANEL DOOR 10.2013 rev.1 DETAILED INSTALLATION INTRUCTIONS GENERAL: Door elevations shown in these instructions are as viewed from the outside. X denotes the active or moving panel(s). O

More information

33/3527A. Devices covered by these instructions: 33/3527A-F (Fire) Surface Vertical Rod Exit Device

33/3527A. Devices covered by these instructions: 33/3527A-F (Fire) Surface Vertical Rod Exit Device *911403-00* 911403-00 Surface Vertical Rod Exit Device 33/3527A Installation Instructions Devices covered by these instructions: 33/3527A Surface Vertical Rod Exit Device 33/3527A-F (Fire) Surface Vertical

More information

VYTEX PREMIUM SLIDING GLASS DOOR. Table of Contents. Precautions and Safety 2. Tools Required...3. Inspect and Prepare Door...4

VYTEX PREMIUM SLIDING GLASS DOOR. Table of Contents. Precautions and Safety 2. Tools Required...3. Inspect and Prepare Door...4 VYTEX PREMIUM SLIDING GLASS DOOR Table of Contents Precautions and Safety 2 Tools Required...3 Inspect and Prepare Door...4 Hardware and Parts Check List....4 Master Frame Assembly 5 Master Frame Installation..7

More information

YOW 225 TU Window System

YOW 225 TU Window System ThermaBond Plus Poured & Debridged Technology YOW 225 TU SYSTEM DESCRIPTION YOW 225 TU PERFORMANCE FEATURES 2-1/4 Overall Depth ThermaBond Plus Poured & Debridged Thermal Break Variations: Casement, Projected

More information

CRL JACKSON 900 SERIES

CRL JACKSON 900 SERIES INSTALLATION INSTRUCTIONS CRL JACKSON 900 SERIES FLOOR MOUNTED DOOR CLOSERS CENTER HUNG AND OFFSET crlaurence.com crlaurence.com MODEL No. 990 crlaurence.com Phone: (800) 421-6144 Fax: (800) 262-3299 crlaurence.com

More information

OVERVIEW. Mounting Post (2 places) Cylinder Cam. Handing Pin

OVERVIEW. Mounting Post (2 places) Cylinder Cam. Handing Pin DEVICES COVERED IN THIS DOCUMENT: 46CE Cylinder Escutcheon Key locks and 46DT Dummy Trim Pull when dogged unlocks lever 46BE Blank Escutcheon Always operable 46NL Night Latch Key retracts latchbolt 46NK

More information

YSG 40/50/50T Window Wall System Installation Manual

YSG 40/50/50T Window Wall System Installation Manual Installation Manual 2004 YKK AP America Inc. is a subsidiary of YKK Corporation of America. TABLE OF CONTENTS Installation Notes........................................ Page ii PARTS DESCRIPTION YSG 40

More information

YVS 400 TU Window System

YVS 400 TU Window System YVS 400 TU SYSTEM DESCRIPTION YVS 400 TU PERFORMANCE FEATURES 4 Overall Depth ThermaBond Plus Poured & Debridged Thermal Break Variations: Single Hung, Double Hung & Fixed Windows 1 /8 & 1 1 /16 Glazing

More information

GENERAL INSTALLATION GUIDELINES

GENERAL INSTALLATION GUIDELINES 1551 MT. ROSE AVENUE YORK PA 17403-2909 (717) 849-8100 GENERAL INSTALLATION GUIDELINES For Receptor Systems Approved 9/29/2017 Installation Guideline Disclaimer This document contains general installation

More information

YES 45 FS/FI Storefront System Installation Manual

YES 45 FS/FI Storefront System Installation Manual Installation Manual 2014 YKK AP America Inc. is a subsidiary of YKK Corporation of America. TABLE OF CONTENTS Installation Notes... Page ii PARTS DESCRIPTION YES 45 FS Framing Members... Page 1 YES 45

More information

Figure #1 - VSNEO Shower Door Assembly

Figure #1 - VSNEO Shower Door Assembly Figure #1 - VSNEO Shower Door Assembly Figure #2 - VSNEO - Top View Figure #3 - VSNEO - Side View Figure #4 - Foam Curb Plug Figure #5 - Magnet Strip Figure #6 - VSNEO - Drip Deflector Preparation VSNEO

More information

INOVO 4-LITE SLIDING PATIO DOOR ASSEMBLY AND INSTALLATION INSTRUCTIONS

INOVO 4-LITE SLIDING PATIO DOOR ASSEMBLY AND INSTALLATION INSTRUCTIONS INOVO 4-LITE SLIDING PATIO DOOR ASSEMBLY AND INSTALLATION INSTRUCTIONS IMPORTANT: READ THE INSTRUCTIONS AND FAMILIARIZE YOURSELF WITH THE DOOR PARTS AND PIECES BEFORE BEGINNING ASSEMBLY AND INSTALLATION.

More information

Pocket Door Installation Instructions

Pocket Door Installation Instructions Installation Instructions Before getting started: Read instructions thoroughly. Be sure that you have the necessary tools and materials before starting the installation. Consult your local building code

More information

Please read and understand all instructions before beginning. These instructions cover impact and non-impact aluminum French Door 650/750.

Please read and understand all instructions before beginning. These instructions cover impact and non-impact aluminum French Door 650/750. The performance and proper operation of a door is only as good as the installation. By following these instructions, the probability of a good installation greatly increases. Please read and understand

More information

Series Exterior glazed curtain wall. Installation Instructions

Series Exterior glazed curtain wall. Installation Instructions Series 5500 Exterior glazed curtain wall Installation Instructions Part NO. Y550 November 2016 TABLE OF CONTENTS SECTION S-5500 SCREW SPLINE CURTAIN WALL PAGE I. General Notes and Guidelines.. 3-4 II.

More information