SERIES CF451T INSTALLATION INSTRUCTIONS. SERIES CF451T 2 x 4½ - B2. Fabrication for Panel Assembly. High Performance Thermal Storefront System
|
|
- Darren Merritt
- 5 years ago
- Views:
Transcription
1 SERIES CF451T INSTALLATION INSTRUCTIONS Fabrication for Panel Assembly High Performance Thermal Storefront System Effective October
2 2 Effective October 2014
3 TABLE OF CONTENTS GENERAL NOTES Common Storefront System Field Failures... 6 Key Elevations... 7 System Component Identification FRAME FABRICATION Determine Frame Size Cut Lengths Fabricate Sill, Vertical & Jamb Members Fabricate Head & Subsill Receptors FRAME ASSEMBLY Assemble Frames Subsill Receptor End Dam FRAME INSTALLATION Install Subsill Receptor Subsill Receptor Splice Install (Optional) Head Receptor Clean Subsill Receptor Expansion Mullion Panel Installation GLAZING ABC s of Glazing Install Water Diverter Glazing Steps SPECIAL CONDITIONS Subsill Receptor at Doorframe Corner Mullions Column Covers Bulkhead/Horizontal BUTT GLAZING Key Elevation and Details Glazing Sequence PERIMETER SEAL Perimeter Seal Sealant Coverage Chart PERIMETER ANCHOR Fastener Embedment Wood Substrate Fastener Schematics Steel Substrate Fastener Schematics Concrete Substrate Fastener Schematics NOTE: These instructions are prepared for Series CF451T. Use these same instructions for Series CF451 non-thermal and delete the T suffix from part numbers. Effective October
4 INSTALLATION INSTRUCTIONS SERIES CF451T 2 x 4½ - B2 PART 1-Handling, Storing and Protection of Aluminum A. PRECAUTIONS: The following precautions are recommended to protect architectural aluminum materials against damage. Following these precautions will help ensure early acceptance of your products and workmanship. B. HANDLE CAREFULLY: All aluminum materials stored at job site must be stored with adequate separation and not stacked directly onto the concrete floor slab to prevent materials from being damaged when handling. Cardboard wrapped or paper interleaved materials must be kept dry. C. CHECK ARRIVING MATERIALS: Check for quantity and keep records of where various materials are stored. D. KEEP MATERIAL AWAY FROM WATER, MUD AND SPRAY: Prevent cement, plaster or other materials from damaging the finish. E. PROTECT MATERIALS AFTER ERECTION: Wrap aluminum section profiles with polyethylene or protect by erecting a polyethylene splatter screen. Cement, plaster, terrazzo, other alkaline solutions and acid based materials used to clean masonry are very harmful to the finish and should be removed with water and mild soap IMMEDIATELY. Please reference AAMA 609 and AAMA for cleaning architectural aluminum. PART 2- General Installation Instructions A. CHECK SHOP DRAWINGS, INSTALLATION INSTRUCTIONS AND GLAZING INSTRUCTIONS to become thoroughly familiar with the project. The SHOP DRAWINGS take precedence and include specific details for the project. The INSTALLATION INSTRUCTIONS are of general nature and cover most common conditions. B. ERECTION: All materials are to be installed plumb, level and true. C. BENCH MARKS: All work should start from bench marks and/or column lines established by the ARCHITECTURAL DRAWINGS and the GENERAL CONTRACTOR with guaranteed accuracy. Check mullion spacing from both ends of masonry opening to prevent dimensional build-up of daylight opening. D. SURROUNDING CONDITIONS: Make certain construction which will receive your materials is in accordance with the contract documents. Notify the general contractor in writing of any discrepancies and resolve differences before proceeding with work. E. ISOLATION OF ALUMINUM: Aluminum to be placed in direct contact with uncured masonry or incompatible materials should be isolated with a heavy coat of zinc chromate or bituminous paint. F. SEALANTS: Sealants must be compatible with all materials which they have contact, including other sealant surfaces. Consult with sealant manufacturer for recommendations relative to joint size, shelf life, compatibility, cleaning/priming, tooling, adhesion, etc. It is the responsibility of the GLAZING CONTRACTOR to submit a statement from the sealant manufacturer indicating that glass and glazing materials have been tested for compatibility and adhesion with glazing sealants, and interpreting test results to relative to material performance, including recommendations for primers and substrate preparation required to obtain adhesion. The chemical compatibility of all glazing materials and framing sealants with each other and with like materials used in glass fabrication must be established. This is required on every project. 4 Effective October 2014
5 INSTALLATION INSTRUCTIONS (Continued) G. FASTENING: Within the body of these instructions, fastening means any method of securing one part to another or to adjacent materials. Only those fasteners used within the system are specified in these instructions. Due to various substrates to which the framing may be attached, structural perimeter anchor fasteners are not specified in these instructions. For structural perimeter fasteners, reference the shop drawings, structural anchor charts or consult with the fastener supplier. H. BUILDING CODES: Glass and glazing codes governing the design and use of products vary widely throughout the USA. Cardinal Commercial Products does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility for these design considerations. It is the responsibility of the owner, specifier, architect, general contractor and installer to make these selections in strict conformance with all applicable codes. I. EXPANSION JOINTS: Expansion joints and perimeter seals shown in these instructions and in the shop drawings are shown at normal size. Actual dimensions may vary due to perimeter conditions and differences in metal temperature between time of fabrication and the time of installation. Detailed instructions and formula used to calculate expansion joints are shown within the body of these instructions. J. FIELD TESTING: It is recommended that AAMA Water Hose Test be conducted once a sufficient portion of the framing is installed, glazed and sealed to ensure proper installation. This test should be repeated on large projects at specific intervals as deemed necessary by job conditions and acceptable quality control standards. K. COORDINATION WITH OTHER TRADES: Coordinate with the GENERAL CONTRACTOR and sequence with other trades any materials which offset your framing installation. For example, backup walls, partitions, ceilings, mechanical ducts, converters, etc. L. FINAL CLEANING (CARE AND MAINTENANCE): Final cleaning of exposed aluminum surfaces should be done in accordance with AAMA publications for anodized aluminum and AAMA for applied painted coatings (liquid or powder). M. PRODUCT DESIGN CHANGES: Cardinal Commercial Products reserves the right to change product designs without prior notice when deemed necessary for product improvement. Please visit our website at for the latest product installation instruction manual prior to commencing work. Effective October
6 COMMON STOREFRONT SYSTEM FIELD FAILURES 1. Product not installed in accordance with manufacturer s installation instructions. 2. Workmanship. 3. Frames not installed level, true and plumb. 4. Frames not anchored properly to substrate to resist dynamic forces of shear, tension and compression. 5. Leaks at subsill pan receptor/flashing due to design or workmanship. 6. Debris left in glazing pockets and subsill pan receptor blocking weep holes. 7. Glazing gaskets not installed properly and failure to seal corners. 8. Water diverters not installed each end of intermediate horizontals. 9. End dams not installed at each end of subsill receptor pan. 10. Glazing: a. Glass not centered into opening. b. Positioning of setting blocks. c. Not using anti-walk blocks in areas prone to seismic movement. d. Not using anti-walk blocks in areas with helicopter traffic. KEY WATER CONTROL FEATURES A well designed storefront system has a full height interior leg with a recessed cavity for holding sealant to ensure a good seal between the subsill pan and the sill framing member. The subsill pan must have a recessed cavity so structural fasteners can be installed, cap sealed and inspected prior to installing the frame panels. To reduce air infiltration and to prevent harmonic whistling noises, each weep hole should be backed by a urethane coated baffle. A High Performance subsill pan design is standard for all Cardinal Commercial Products storefront systems. AVOID THESE COMMON INSTALLATION PRACTICES C D A E B A Sill flashing interior leg less than full height B C D Blind seal E Fastener penetrating interior flashing leg Fig Effective October 2014
7 SYSTEM COMPONENT IDENTIFICATION A KEY ELEVATION NOTE: These instructions are prepared for Series CF451T. Use these same instructions for Series CF451 non-thermal and delete the T suffix from part numbers. 2A 2B 1A CF451-13T CF451-4T CF451-1T CF451-4T CF451-5T CF451-7T CF451-8T CF451-1T MASONRY 1 /4" FRAME HEIGHT 1 /4" 4 1 / GSK-1 (Typ) CF451-17T D.L.O. D.L.O. D.L.O. D.L.O. * * ⅜" FRAME WIDTH ⅜" MASONRY *Includes 1/8 allowance for subsill receptor MULLION LENGTH D.L.O. D.L.O. CF451-3 CF / 3 CF451-13T CF451-2T 4 CF451-2T CF451-6T 5 MASONRY FRAME HEIGHT MULLION LENGTH D.L.O. D.L.O. CF451-2T CF451-2T CF / 3 CF CF451-3 CF451-2T CF451-6T 5 1 /4" 1 / 3 /4" 1 /4" 1 / 3 /4" EXTERIOR GLAZE Fig. 7.1 INTERIOR GLAZE Effective October
8 SYSTEM COMPONENT IDENTIFICATION SERIES CF451T 2 x 4½ - B2 DESCRIPTION Head & Sill Receptors Head Receptor (Combination) FRAMING SECTIONS Note: Delete "T" suffix from part number for non-thermal. Sill Receptor CF Head CF450-18T Head (Optional at Head Receptor) CF451-6T Sill/Intermediate Horizontal (Combination) Horizontal Sections CF451-3 CF451-13T CF451-1T CF451-2T Jamb Mullion (Standard) Mullion (Heavy Duty) Expansion Mullion (Male Half) (Female Half) Mullion Filler Jamb Filler Vertical Sections CF451-13T CF451-1T CF451-5T CF451-7T CF451-8T CF451-4T CF450-17T Glass Pocket Adaptors and Fillers Transition Adaptor (1" to ¼") CF Transition Adaptor (1" to ½") CF Glazing Pocket Filler CF Trim 90 Single Pocket (Pocket at Male Snap) 90 Two Pocket 90 Single Pocket (Pocket at Female Snap) 90 Corner Mullion Halves CF CF451-9T CF451-10T CF451-12T 45 /135 Corner Adaptors (Used with CF451-8T) CF Sill & Intermediate Horizontal Bulkhead (Used with CF451-3 Glass Stops) CF451-3 Other Adaptors CF451-11T CF451-8T CF Fig Effective October 2014
9 SYSTEM COMPONENT IDENTIFICATION DESCRIPTION FRAME SHAPES Door Jamb (Offset Pivots) Door Jamb (Center & Butt Hung) Doorframe Jambs CF CF Door Header (Offset Pivots) Door Header (Offset Hung for Offset Arm) Door Header (Center Hung) Doorframe Headers CF CF CF CF Doorframe Stops and Sash Threshold DESCRIPTION Offset Arm Cover Snap-In Door Stop (1" Glazing Pocket) Threshold (for Offset & Center Hung) Surface Applied Door Stop and Steel Clip ACCESSORIES Transom Sash & Stop (1" Glazing) CF200-1 CF200-8 CF200-3 CDH-23-1 CF200-5 CF200-4 Use GSK-5 Gasket T450 CDH-24-1 Threshold Clip Gaskets and Weather Strips GSK-1 (Standard) Glazing Tape GSK-2 (Light) Glazing Gaskets GSK-3 GSK-4 GSK-7 (Heavy) (Door) Two Finger Gasket Setting Block for 1 Glass Wool Pile Weather Strips WP-2 Weep Baffel (30 PPI) WP-4 (Doorframe) GT-1 SB-3 (Outside Glaze) SB-4 (Inside Glaze) SB-6 (Butt Glaze) WB-1 Miscellaneous #12 X 1¼ PH Square Drive Zinc Plated SMS Drive Bit #10 X 3/8 PPH Zinc Plated Anti-Walk Block (1" Glazing) Water Diverter (1" Glazing) End Dam AF12-4 AF12-5 AF10-4 AW-2 WD ED-451 Fig. 9.1 Effective October
10 DETERMINE FRAME SIZE SERIES CF451T 2 x 4½ - B2 DETERMINE SQUARENESS Check opening for squareness to Plumb at both ends. Frames must be installed in a true rectangle. See Fig ERECTION TOLERANCE: 1. Within any rectangular opening there should be no more than 1/8 difference between dimension "A" & "B". Plumb Dimension "A" Dimension "B" Dimension "A" = "B" Fig DETERMINE FRAME WIDTH Measure the width of the masonry opening at top, middle and bottom. Select the smallest dimension measured and subtract 1/ to determine frame width. See Fig ERECTION TOLERANCES: 2. Maximum variation of mullions from plumb or horizontals from level should not exceed 1/8 in 12-0 or 1/4 in any single run. 3. To assure the stated tolerances for item 2 are not exceeded in the erected framing, low cost go/no-go gauges can generally be made for use by the framing erector. * * ⅜" Measure Measure Measure Frame Width Masonry Opening *Includes 1/8 allowance for subsill recepror Fig DETERMINE FRAME HEIGHT Measure the height of masonry opening several times along the entire length of opening. Select the smallest dimension for the masonry opening height. See Fig ⅜" Measure Measure Measure Measure Measure 1" 1/4" Mullion Length Frame Height Masonry Opening CONTINUOUS HEAD AND SILL Subtract: 1/2 from the masonry opening height. 1/4 caulk joint at head above head. 1/4 caulk joint below sill receptor. Fig CF451T-6 1/4" 10 Effective October 2014
11 FRAME MEMBER CUTTING NOTE: These instructions are prepared for Series CF451T. Use these same instructions for Series CF451 non-thermal and delete the T suffix from part numbers. AF12-4 (Typ) NOTE: CF451-4T is handed CF451-13T CF451-13T CF451-3 CF451-2T CF451-4T CF451-1T CF451-3 CF451-2T CF451-3 CF451-2T CF451-3 CF451-2T CF451-6T Fig Effective October
12 FRAME MEMBER CUTTING SERIES CF451T 2 x 4½ - B2 CUT SECTIONS TO SIZE Sill Receptor: = Overall Frame Width PLUS ¼ to allow for last panel installation. Mullion, Pocket Filler & Jamb Members: Without Head Receptor = Frame Height MINUS 1. Head, Horizontal & Sill: = Daylight Opening. Glazing Beads: = Daylight Opening MINUS 1 /32. CF451-13T HEAD CF451-13T JAMB CF451-1T MULLION & CF451-4T FILLER CF451-3 GLASS STOP FRAME HEIGHT CF451-2T INTERMEDIATE HORIZONTAL CF451-3 GLASS SILL CF451-2T SILL CF451-6T SILL RECEPTOR 1/8" NOTE: CF451-6T is cut Frame Width + 1/4" FRAME WIDTH 1/8" Fig Effective October 2014
13 FRAME MEMBER CUTTING NOTE: These instructions are prepared for Series CF451T. Use these same instructions for Series CF451 non-thermal and delete the T suffix from part numbers. Frame with optional Head Receptor (Not recommended for high wind loads) CF450-18T CF CF451-13T CF451-13T NOTE: CF451-4T is handed CF451-3 CF451-2T AF12-4 (Typ) CF451-4T CF451-1T CF451-3 CF451-2T CF451-3 CF451-2T CF451-3 CF451-2T CF451-6T Fig Effective October
14 FRAME MEMBER CUTTING SERIES CF451T 2 x 4½ - B2 CUT SECTIONS TO SIZE Sill Receptor (Standard) & Head Receptor (Optional): = Overall Frame Width PLUS ¼ to allow for last panel installation. Mullion, Pocket Filler & Jamb Members: With Optional Head Receptor = Frame Height MINUS 1¾. Head, Horizontal & Sill: = Daylight Opening. Frame with optional Head Receptor Glazing Beads: = Daylight Opening MINUS 1 /32. NOTE: CF450-18T and CF are cut Frame Width + 1/4" 1/8" 1/8" CF450-18T HEAD RECEPTOR CF HEAD RECEPTOR BEAD CF451-1T HEAD CF451-13T JAMB FRAME HEIGHT CF451-1T MULLION & CF451-4T FILLER CF451-3 GLASS STOP CF451-2T INTERMEDIATE HORIZONTAL CF451-3 GLASS SILL CF451-2T SILL CF451-6T SILL RECEPTOR 1/8" NOTE: CF451-6T is cut Frame Width + 1/4" FRAME WIDTH Fig /8" 14 Effective October 2014
15 SILL MEMBER FABRICATION Cut sill members to length as determined in Fig or Drill holes for attachment to subsill. Reference Fig for panel installation. Cut Length = D.L.O. CF451-2T (Sill).500" Ø.21 Hole (#3 Bit) BOTTOM VIEW of CF451-2T SILL MEMBER Fig Effective October
16 7 /3 SERIES CF451T 2 x 4½ - B2 7 /8" 2 3 /4" 7 /8" 7 /3 7 /3 7 /3 7 / /3 VERTICAL MEMBER FABRICATION Cut vertical members to length as determined in Fig or Mark location for Head, Horizontal and Sill. Reference Fig. 7.1 for typical elevation. VERTICALS - Drill screw spline holes for HEAD, HORIZONTAL and SILL as shown below. NOTE: CF451-4T is handed. Align in proper orientation with CF451-1T and CF451-5T holes for intermediate horizontal. DRILLING SCREW SPLINE HOLES INTO VERTICAL MEMBERS CF451-7T CF451-8T CF451-4T CF451-5T NOTE: CF4541-4T and CF451-8T are handed due to offseting thermal cavities CF451-1T HEAD DG451 Drill with #2 (Ø.221) Bit HORIZONTAL 2 25 /3 SILL DG451 DG451 DG451 DRILL GUIDE NOTE: Never allow two shallow glazing pockets to face each other within any elevation. Plan vertical fabrication and panel assembly accordingly. NOTE: Drill screw spline holes in 90 corner sections in similar manner using DG451 Drill Guide. Fig Effective October 2014
17 SILL RECEPTOR FABRICATION Cut CF451-6T sill receptor to frame width + 1/4 as determined in Fig or NOTE: CF451-6T is offered with weep holes prefabricated as shown in Fig Fabricate weep holes as shown in Fig with holes approximately 2 from edge of each vertical member. Jamb Mullion Mullion CF451-6T End of Sill Receptor Fig /4" Ø Weep Holes Drill ø 9/32 holes for anchoring CF451-6T to substrate as shown in Fig Anchoring hole dimensions are located approximately 2 each side of vertical mullion. CF451-6T ⅛" D.L.O. D.L.O. Ø 9/3 Holes ⅛" 2 21 /3 Fig NOTE: The anchor holes shown above are for illustration only. Please reference ANCHOR SCHEMATICS on pages to determine location and number of holes required based on substrate prior to fabrication. Effective October
18 HEAD RECEPTOR FABRICATION (OPTIONAL) SERIES CF451T 2 x 4½ - B2 Cut head receptor to Frame Width + 1/4 as determined in Drill ø 9/32 holes for anchoring CF450-18T to substrate as shown in Fig Anchoring hole dimensions are located approximately 2 each side of vertical mullion. (Reference Fig regarding number of anchor holes) ⅛" D.L.O. D.L.O. Ø 9/3 Holes ⅛" 3 5 /8" CF450-18T NOTE: Insert GSK-7 lace-in gasket prior to installation. Fig Cut CF receptor bead to Frame Width + 1/4 as determined in Fig Frame Width + ¼" CF NOTE: Insert GSK-7 lace-in gasket prior to installation. Fig Effective October 2014
19 EXTERIOR GLAZE PANEL ASSEMBLY Exterior Glazed Cut and apply GT-1 sealant tape to verticals at locations where horizontal members intersect as shown in Fig Assembled panels with screws and trim excess tape at joints as required. GT-1 Sealant Tape Protective Cover NOTE: Never allow two shallow glazing pockets to face each other within any elevation. Plan panel and mullion fabrication accordingly. Sealant Tape GT-1 Sealant Tape AF12-4 (Typ) AF12-4 (Typ) 1¾" 1¾" GT-1 Sealant Tape Fill gasket reglet with a bead of sealant at bottom of mullion and filler as shown. Fig Effective October
20 INTERIOR GLAZE PANEL ASSEMBLY SERIES CF451T 2 x 4½ - B2 Interior Glazed Cut and apply GT-1 sealant tape to verticals at locations where horizontal members intersect as shown in Fig Assemble panel with screws and trim excess tape at joints as required. GT-1 Sealant Tape Protective Cover Sealant Applied during frame panel assembly Sealant Applied just prior installing CF451-3 glass stop Sealant Applied during frame panel assembly Sealant Tape Sealant Applied just prior installing CF451-3 glass stop GT-1 Sealant Tape AF12-4 (Typ) AF12-4 (Typ) Sealant GT-1 Sealant Tape Fill gasket reglet with a bead of sealant at bottom of mullion and filler as shown. Sealant should be wet when gaskets are installed. NOTE: Never allow two shallow glazing pockets to face each other within any elevation. Plan panel and mullion fabrication accordingly. Fig Effective October 2014
21 PANEL ASSEMBLY Install GSK-1 gaskets into assembled frames as shown in Fig Reference Fig for gasket cutting and installation methods. Install GSK-1 gaskets into interior reglets in assembled panels. Fig SILL RECEPTOR END DAM INSTALLATION Butter ED-451 end dams with sealant and attach to each end of CF451-6T as shown in Fig Apply sealant to joint as shown and tool to ensure good tight joint. ED-451 GT-1 Cut GT-1 tape to length and apply to ED-451 End Dam as shown. Peal protective cover from tape prior to appling to sill receptor. ED-451 Install ED-451 End Dam at each end of CF451-6T sill receptor. CF451-6T Fig Reference Fig for shim support at each end. Apply sealant and tool to ensure water tight joint. ED-451 Apply sealant full length in C slot just prior to installing assembled panels. CF451-6T Effective October
22 SILL RECEPTOR INSTALLATION SERIES CF451T 2 x 4½ - B2 Position CF451-6T and match drill through anchor holes into substrate with required bit size to specified depth. Clean debris from drilled holes. Shim for proper gap and leveling. Shims must be placed at center of each anchor location. Force sealant into anchor holes and secure with screws. Cap seal all screw heads and tool sealant. The Sill Receptor must be set level and straight. There is no practical way to level the sill receptor after glazed panels are installed. A sill receptor not level and straight will cause uneven gaps at verticals. NOTE: CF451-6T sill receptor must be level. Reference Fig. 10.1, 10.2 & ED451 End Dam Position CF451-6T as required. Match drill through holes into substrate as specified by fastener manufacture. Force sealant into anchor holes and secure to substrate. Cap seal over screw heads and tool sealant. Fig SP-450 Splice sleeve (4" x 1 / 16" x 8") Trim length as required Apply bead of sealant at each end of receptor to receive splice sleeve. Fill area behind perimeter sill bridging gap between sill receptor Marry sealant of spice to perimeter seal. Apply sealant full length in C slot just prior to installing assembled panels. Sealant should fill thermal break cavity. Tool sealant Seal interior vertical joint and tool excess sealant. If use of optional CF450-18T Head Receptor is required, splicing method is similar to method shown for CF451-6T Subsill Receptor as shown above. Fig Effective October 2014
23 OPTIONAL HEAD RECEPTOR INSTALLATION When using a head receptor, fabricate a STOREY GAUGE to accurately gage spacing between CF451-6T sill receptor and CF450-18T head receptor. (Reference Fig regarding number of anchor holes) NOTE: GSK-7 gasket must be installed in reglet of CF450-18T head receptor prior to assembly. If use of optional CF450-18T Head Receptor is required, long runs must be spliced similar to method shown for CF451-6T Subsill Receptor. See Fig /4" Min. SHIM CF450-18T with GSK-7 gasket STOREY GAUGE CF451-6T Level and Plumb NOTE: Reference tolerances in Fig. 16.1, 16.2 & 16.3 Fabricate optional Storey Gauge from special cut CF451-1T vertical mullion sections. STOREY GAUGE CUT GAUGE TO MULLION LENGTH PLUS 3/4" MINIMUM ENGAGEMENT Position CF450-18T as required. Match drill through anchor holes into substrate as specified by fastener manufacture. Force sealant into anchor holes and secure to substrate. Fig Install GSK-7 Gasket Cap seal over screw heads and tool sealant. Effective October
24 SILL RECEPTOR INSTALLATION SERIES CF451T 2 x 4½ - B2 Remove all debris from CF451-6T sill receptor with Shop Vac to prevent blockage of weep holes. See Fig 24.1 Debris ED-451 Use a Shop Vac to remove all debris from sill receptor. Apply sealant full length in C slot just prior to installing assembled panels. Fig Shim between ED-451 End Dams and structure to prevent knocking dam loose and damaging seal. Install WB-1 weep baffles by pressing into reveal and center on each weep hole. ED-451 End Dam Cap seal head of fasteners Center WB-1 baffle on each weep hole ED-451 Baffles reduce air and water infiltration. Weep holes without baffles can cause harmonic whistling noise on the inside of building by gusting winds. Shim Weep hole Fig Effective October 2014
25 EXPANSION MULLION An expansion mullion is to be used every 20'-0" in wide openings. The dimension of the assembly should be adjusted based on the temperature at the time of installation. Generally, horizontal expansion joints should be no further apart than 20 feet. Expansion should be from the center toward both ends to minimize joint movements and thereby reduce stresses on sealants and connectors. CF451-7T CF451-8T Calculate gap (See Example Below) Fig Expansion gap is determined by job conditions, project specifications and temperature at time of installation. Expansion mullions allow for 3/8 maximum movement. EXPANSION GAP SIZE FORMULA = LENGTH ( ) X F DIFFERENCE X L = Length in inches between centerline of expansion mullion in elevation. F = Specified temperature variation = Thermal coefficient for aluminum EXAMPLE: Assume 100 temperature variation specified and temperature at job site on day of installation is = 40 temperature difference 2. Length of elevation between expansion mullions equals 20-0 or x x 40 =.124. Therefore, set expansion gap at 1/8. Cut expansion mullions as determined in Fig and Fabricate expansion mullions as shown in Fig Cut GSK-7 gaskets 1/8 longer per foot than mullion length. Lace GSK-7 gaskets into interior and exterior reglets. Crimp reglet at each end to prevent gasket slippage. CF451-7T Crimp reglets at each end on both sides to prevent gasket slippage Lace GSK-7 into exterior and interior reglets of CF451-7T. Fig Effective October
26 PANEL INSTALLATION SERIES CF451T 2 x 4½ - B2 Install assembled panels into sill receptor. NOTE: Apply a continuous bead of sealant into C -slot prior to installing frame panels. Weep Baffle NOTE: Never allow two shallow glazing pockets to face each other within any elevation. Plan panel and mullion fabrication accordingly. Fig NOTE: CF451-4T is handed INTERMEDIATE PANEL NOTE: CF451-4T is handed LAST PANEL NOTE: CF451-4T is handed EXPANSION MULLION PANEL Fig Effective October 2014
27 PANEL INSTALLATION After assembled panels have been installed, anchor CF451-2T sill to CF451-6T subsill with AF10-4 (#10 x 3/8 PPH SMS) as shown in Fig For hole/screw location see Fig ELEVATION AF10-4 installed approximately on each side of mullion. NOTE: Push panels tightly against back of subsill prior to anchoring. CF451-2T Tool excess sealant. CF451-6T Apply continuous bead of sealant into reveal. Fig Effective October
28 GLAZING SERIES CF451T 2 x 4½ - B2 REMOVE ALL TRASH FROM GLAZING POCKETS AND REGLETS Set glass on setting blocks positioned at 1/4 points in opening. Reference "Dead Load Charts" for location of setting blocks at horizontal. Setting blocks should not be placed closer than 6" from the edge of glass for typical conditions. GLASS SIZE = DAYLIGHT (D.L.O.) + 7/8 Note: This formula does not allow for undersized or out of square daylight openings. The glass manufacturer must indicate the specific glazing requirements for the material being used. Glass "A" "B" D.L.O. 6" (min.) 4" long setting block (min.) 1/4 1/2 1/4 Setting block (2 per lite) Reference Dead Load Charts D.L.O. Fig Fig Cut horizontal and vertical gaskets D.L.O. + 1/8 per foot of D.L.O. to allow for shrinkage. (Ref. Fig. 28.2) It is important that gaskets are cut and installed as shown in Fig Vertical gaskets run between horizontal gaskets. "C" 2. Start head and jamb gaskets at centers of opening and corners. 3. Start sill gasket at setting block locations and corners. Fig Effective October 2014
29 GLAZING CORNER TREATMENT Glazing gaskets are prone to shrink and pull away at the corners over a period of time allowing for excessive air and water infiltration at the corners. Standard glazing practice is to provide corner treatment to ensure tightness on the exterior and interior corner intersections. NOT RECOMMENDED Notched Corners - The corners of the rubber gaskets are notched on the underside without cutting the nearside. The gasket is installed in one length and is butt joined in the center of horizontal section. While this method of glazing is widely used for marine glazing, residential sliding doors and shower doors, it is not recommended for commercial window wall glazing. Notched Corner - Not Recommended Fig RECOMMENDED Seal Corners - Pull gaskets back in both directions from interior and exterior corners as shown in Fig and apply sealant. This should be done on the interior (inside glaze) or exterior (outside glaze) for best performance. While long-term adhesion to the rubber gaskets with sealant is nor assured, historical field experience has proven this type of corner treatment to be the next best method short of vulcanized gasket corners. Reference ABC's of Glazing Fig. 28.1, 28.2 & Sealant (Typical) VIEWED FROM EXTERIOR Fig Effective October
30 GLAZING SERIES CF451T 2 x 4½ - B2 NOTE: Glaze system from bottom to top. Installing WD-451 water deflector at ends of intermediate horizontal as glass is being installed. WD-451 are installed into a bed of sealant as shown in Fig & WD-451 Water Deflector Silicone Sealant Apply a bed of sealant at ends of horizontal. Press WD-451 water deflectors into sealant and tool sealant. Fig Force sealant into reglets on vertical members as shown in Fig Tool sealant smooth around flat of Water Deflector in horizontal member to limit water damming. After Water Deflectors are in place, inject additional sealant down into vertical gasket reglets and tool excess sealant. Fig Glass 30 Effective October 2014
31 GLAZING EXTERIOR GLAZING 1. Press interior gaskets into reglets on all four sides. See Fig & From the exterior, insert edge of glass into deep pocket vertical. 3. Swing opposite edge in and align with pocket. 4. Center glass in opening. 5. Lift glass to allow setting block insertion. 6. Position setting blocks at points under glass as required. See Fig Install glazing bead. 8. Press exterior gaskets into reglets on all four sides. See Fig GSK-1 8 SB GSK-1 2 NOTES: - GSK-1 Interior Gasket may be installed into panels at shop prior to transporting to job site. - GSK-1 gasket is used on interior and exterior side of glass. 3 8 Fig GSK-1 GSK SB Install AW-2 Anti-Walk block into deep pocket near mid-point of vertical mullion. AW-2 AW-2 TOP VIEW VIEWED FROM EXTERIOR Fig Effective October
32 SPECIAL CONDITIONS SILL RECEPTOR AT FRAME SERIES CF451T 2 x 4½ - B2 CF451-6T Sill Receptor Completely dam void at end of sill receptor with sealant. Marry sealant with exterior and interior perimeter sealant. Door Jamb (CF Shown) T450 Threshold Fill gaskets with sealant Door Jamb (CF Shown) Seal as shown CF451-6T Sill receptor T450 Threshold Seal exposed hole at each end of threshold for offset hung doors Weep hole (Weep Baffle not shown) Fig Continuous seal along interior line at bottom of doorframe and side light. CF451-6T Sill Receptor Perimeter sealant at sill receptor T450 Threshold CF451-4T Open back filler of side light panel CF Door Jamb Fig CF200-8 Snap-in door stop Sealant in exposed hole at threshold offset 32 Effective October 2014
33 SPECIAL CONDITIONS CORNER INSTALLATION Construct sill receptor corners as shown in Fig Outside Corner is shown, Inside corners and other corner angles are similar. Prepare and seal splice joints as shown in Fig Anchor sill receptors as shown. Cap seal all fastener heads. CF451-6T CL of splice Apply sealant to miter joint at corners. 1 18" 1 CL of Splice 18" Fig Install each corner half. Install adjacent straight panels working out from corner assembly. NOTE: Apply a continuous bead of sealant into C -slot prior to installing frame panels. Fig Effective October
34 SPECIAL CONDITIONS COLUMN COVER INSTALLATION SERIES CF451T 2 x 4½ - B2 Fabricate CF451-8T female half of expansion mullion as shown in Fig and Assemble column cover panels and install as shown in Fig below. Seal interior & exterior gap at break metal and sill receptor fin. Seal joint of sill receptor and around column Formed Aluminum Trim Metal Column CF451-8T Apply sealant to all expansion mullion reglets recieving break metal. Seal interior & exterior gap at break metal and sill receptor fin. Seal joint of sill receptor and around column Aluminum Trim CF451-8T Varies CF451-8T CF451-8T 90º Varies Seal interior & exterior gap at break metal and sill receptor fin. Seal joint of sill receptor and around column Formed Aluminum Trim CF451-8T CF451-8T Varies Fig Effective October 2014
35 SPECIAL CONDITIONS BULKHEAD/HORIZONTAL Just prior to glazing, run a continuous bead of sealant into interior glass stop receptor hook. Install CF451-3 Glass Stop at interior. (Vertical mullions not shown) CF451-3 CF451-11T CF451-4T BULKHEAD INTERMEDIATE HORIZONTAL Attach CF451-11T Bulkhead to CF451-6T Sill Receptor with #10 x 2⅛" PH SMS from each end and one at center. CF451-3 CF451-11T Snap-in CF451-4T Filler as shown. Fabricate weep holes as shown in Fig BULKHEAD SILL CF451-6T Fig Effective October
36 BUTT GLAZING SERIES CF451T 2 x 4½ - B2 1 1A (Optional) 1 1A (Optional) 1A 1 7 Opp Opp Opp KEY ELEVATIONS Entrance MASONRY FRAME HEIGHT MULLION LENGTH DLO 1 /4" ½" Glass Bite 1 CF451-13T CF / Glass 4 1 / MASONRY FRAME HEIGHT MASONRY FRAME HEIGHT MULLION LENGTH SB-6 Setting Block 2 1 /4" 7 /16" 11 /16" 1 /4" DLO CF / 1A CF451-2T GSK-2 Optional Head DLO ½" Glass Bite CF CF451-13T CF451-6T 3 Structural Silicone 4 5 Optional steel reinforcement as required by design load. CF451-13T CF / 1 / CF451-4T CF CF200-3 GSK-2 (Typ) * ⅜" DLO FRAME WIDTH MASONRY *Includes allowance for subsill. 1 / Butt Joint Fig Effective October 2014 D.L.O. FRAME WIDTH MASONRY Offset hung narrow stile door shown
37 BUTT GLAZING Install left and right jamb lights (A & B) first followed by intermediate lights (C). Glass Frame A B C A A B Fig ½" Butt Joint Painters masking tape Glass Glass 2 4 Painters masking tape Seal joint gaps with structural silicone SB-6 Setting Block Fig NOTE: Install and position setting blocks prior to glass installation. Fig Effective October
38 PERIMETER SEAL SERIES CF451T 2 x 4½ - B2 Apply continuous exterior and interior perimeter seal to elevation as shown in Fig Marry exterior and interior sealant to jamb sealant as shown below in Detail 4 of Fig Opposite ELEVATION Fig Sealant & Backer Rod Sealant & Backer Rod Jamb substrate not shown Sealant & Backer Rod Sealant & Backer Rod 4 Marry exterior and interior sealant to form one continuous perimeter seal as shown. Fig Effective October 2014
39 PERIMETER SEALANT COVERAGE SEALANT COVERAGE CHART This chart may be used to estimate the sealant tubes or sausages required based on the average joint size and lineal feet to be sealed. To use the chart you must know the depth and width of the joint. For example, 1 tube of sealant yields approximately 16.2 feet in a joint 3/8" deep x 1/4" wide. (See other Example below in Fig. 39.1) JOINT SIZE Depth X Width (Inches) FEET per TUBE FEET per SAUSAGE Framing system Sealant.125 x x x x x x x x SEALANT WIDTH Backer Rod Substrate.250 x x x x x x x SEALANT DEPTH.375 x x x x x x tube = 10.1 Ounce.500 x x x x x x x x x x x x x x Sausage = 20 Ounce FOR EXAMPLE: 1. Job requires 1000 feet exterior and interior caulking. 2. Aveage caulk space =.25 X Yield/tube from chart = Yield/sausage from chart = = 42 tubes required (Rounded up) = 21 sausages required (Rounded up) 1.00 x Fig Effective October
40 PERIMETER ANCHORING FASTENER EMBEDMENT SERIES CF451T 2 x 4½ - B2 WOOD SUBSTRATE (For #2 Southern Yellow Pine) CONCRETE SUBSTRATE (For 3,000 PSI Concrete) B A+B B A+B A A 2½" Min. Edge Distance A = Framing Thickness Including Shim Space B = 2½" Minimum Embedment A+B = Anchor Screw Length Min. Edge Distance A = Framing Thickness Including Shim Space B = 1¾" Minimum Embedment A+B = Anchor Screw Length Lag Bolt (Wood) Installation Instructions Fabricate anchor holes in framing at locations shown in Anchor Charts. Concrete Screw Installation Instructions Fabricate anchor holes in framing at locations shown in Anchor Charts. Fig Effective October 2014
41 PERIMETER ANCHORING FASTENER LOCATION SCHEMATICS 0-20 PSF INTO WOOD SUBSTRATE Mid-Point 48" Max. 7 STANDARD LOCATIONS D.O.H. A B 84" " - 94⅜" Mid-Point 48" Max. 7 FASTENER LEGEND for #2 S.Y.P. WOOD SUBSTRATE = 1/4" Lag Bolts 2½" Minimum Embedment with filler plate full length of mullion. Minimum Spacing. = 1/4" Lag Bolts 2½" Minimum Embedment. Minimum Spacing. = #14 Wood Screws 2½" Minimum Embedment. See Fig for Embedment Description 4 4 Effective October
42 PERIMETER ANCHORING FASTENER LOCATION SCHEMATICS PSF INTO WOOD SUBSTRATE SERIES CF451T 2 x 4½ - B2 Mid-Point STL-1 Steel Reinforcement 48" Max. 7 STANDARD LOCATIONS D.O.H. A B 84" 44" 8 96" 50" 94⅜" Mid-Point 48" Max. 7 FASTENER LEGEND for #2 S.Y.P. WOOD SUBSTRATE = 1/4" Lag Bolts 2½" Minimum Embedment with filler plate full length of mullion. Minimum Spacing. = 1/4" Lag Bolts 2½" Minimum Embedment. Minimum Spacing. = #14 Wood Screws 2½" Minimum Embedment. See Fig for Embedment Description Effective October 2014
43 SERIES CF451T 2 x 4½ - B2 PERIMETER ANCHORING FASTENER LOCATION SCHEMATICS PSF INTO WOOD SUBSTRATE Mid-Point STL-1 Steel Reinforcement 48" Max. 7 STANDARD LOCATIONS D.O.H. A B 84" 44" 8 96" 50" 94⅜" Mid-Point STL-1 Steel Reinforcement 48" Max. 7 FASTENER LEGEND for #2 S.Y.P. WOOD SUBSTRATE = 1/4" Lag Bolts 2½" Minimum Embedment with filler plate full length of mullion. Minimum Spacing. = 1/4" Lag Bolts 2½" Minimum Embedment. Minimum Spacing. = #14 Wood Screws 2½" Minimum Embedment. See Fig for Embedment Description 4 4 Effective October
44 PERIMETER ANCHORING FASTENER LOCATION SCHEMATICS PSF INTO WOOD SUBSTRATE SERIES CF451T 2 x 4½ - B2 Mid-Point STL-1 Steel Reinforcement 48" Max. 7 STANDARD LOCATIONS D.O.H. A B 84" 44" 8 96" 50" 94⅜" Mid-Point STL-1 Steel Reinforcement 48" Max. 7 FASTENER LEGEND for #2 S.Y.P. WOOD SUBSTRATE = 1/4" Lag Bolts 2½" Minimum Embedment with filler plate full length of mullion. Minimum Spacing. = 1/4" Lag Bolts 2½" Minimum Embedment. Minimum Spacing. = #14 Wood Screws 2½" Minimum Embedment. See Fig for Embedment Description Effective October 2014
45 PERIMETER ANCHORING FASTENER LOCATION SCHEMATICS 0-20 PSF INTO STEEL SUBSTRATE Mid-Point 48" Max. 7 STANDARD LOCATIONS D.O.H. A B 84" " - 94⅜" Mid-Point 48" Max. 7 FASTENER LEGEND for STEEL SUBSTRATE - FY = 36 KSI Min. = 1/4" Tek Anchor with filler plate full length of mullion. = 1/4" Tek Anchor 4 4 Effective October
46 PERIMETER ANCHORING FASTENER LOCATION SCHEMATICS PSF INTO STEEL SUBSTRATE SERIES CF451T 2 x 4½ - B2 Mid-Point STL-1 Steel Reinforcement 48" Max. 7 STANDARD LOCATIONS D.O.H. A B 84" " 48" 94⅜" Mid-Point 48" Max. 7 FASTENER LEGEND for STEEL SUBSTRATE - FY = 36 KSI Min. = 1/4" Tek Anchor with filler plate full length of mullion. = 1/4" Tek Anchor Effective October 2014
47 PERIMETER ANCHORING FASTENER LOCATION SCHEMATICS PSF INTO STEEL SUBSTRATE Mid-Point STL-1 Steel Reinforcement 48" Max. 7 STANDARD LOCATIONS D.O.H. A B 84" " 48" 94⅜" Mid-Point STL-1 Steel Reinforcement 48" Max. 7 FASTENER LEGEND for STEEL SUBSTRATE - FY = 36 KSI Min. = 1/4" Tek Anchor with filler plate full length of mullion. = 1/4" Tek Anchor 4 4 Effective October
48 PERIMETER ANCHORING FASTENER LOCATION SCHEMATICS PSF INTO STEEL SUBSTRATE SERIES CF451T 2 x 4½ - B2 Mid-Point STL-1 Steel Reinforcement 48" Max. 7 STANDARD LOCATIONS D.O.H. A B 84" " 49" 94⅜" Mid-Point STL-1 Steel Reinforcement 48" Max. 7 FASTENER LEGEND for STEEL SUBSTRATE - FY = 36 KSI Min. = 1/4" Tek Anchor with filler plate full length of mullion. = 1/4" Tek Anchor Effective October 2014
49 PERIMETER ANCHORING 0-20 PSF INTO CONCRETE SUBSTRATE Mid-Point 48" Max. 7 STANDARD LOCATIONS D.O.H. A B 84" - 82¼" 96" - 94¼" Mid-Point 48" Max. 7 FASTENER LEGEND for 3,000 PSI CONCRETE SUBSTRATE = 1/4" Tapcon 1¾" Minimum Embedment. Minimum Edge Distance. with filler plate full length of mullion. = 1/4" Tapcon 1¾" Minimum Embedment. Minimum Edge Distance. See Fig for Embedment Description 4 4 Effective October
50 PERIMETER ANCHORING FASTENER LOCATION SCHEMATICS PSF INTO CONCRETE SUBSTRATE SERIES CF451T 2 x 4½ - B2 Mid-Point STL-1 Steel Reinforcement 48" Max. 7 STANDARD LOCATIONS D.O.H. A B 84" " 48" 94⅜" Mid-Point 48" Max. 7 FASTENER LEGEND for 3,000 PSI CONCRETE SUBSTRATE = 1/4" Tapcon 1¾" Minimum Embedment. Minimum Edge Distance. with filler plate full length of mullion. = 1/4" Tapcon 1¾" Minimum Embedment. Minimum Edge Distance. See Fig for Embedment Description Effective October 2014
51 PERIMETER ANCHORING FASTENER LOCATION SCHEMATICS PSF INTO CONCRETE SUBSTRATE Mid-Point STL-1 Steel Reinforcement 48" Max. 7 STANDARD LOCATIONS D.O.H. A B 84" 4 82¼" 96" 48" 94¼" Mid-Point STL-1 Steel Reinforcement 48" Max. 7 FASTENER LEGEND for 3,000 PSI CONCRETE SUBSTRATE = 1/4" Tapcon 1¾" Minimum Embedment. Minimum Edge Distance. with filler plate full length of mullion. = 1/4" Tapcon 1¾" Minimum Embedment. Minimum Edge Distance. See Fig for Embedment Description 4 4 Effective October
52 PERIMETER ANCHORING FASTENER LOCATION SCHEMATICS PSF INTO CONCRETE SUBSTRATE SERIES CF451T 2 x 4½ - B2 Mid-Point STL-1 Steel Reinforcement 48" Max. 7 STANDARD LOCATIONS D.O.H. A B 84" 43½" 8 96" 49½" 94⅜" Mid-Point STL-1 Steel Reinforcement 48" Max. 7 FASTENER LEGEND for 3,000 PSI CONCRETE SUBSTRATE = 1/4" Tapcon 1¾" Minimum Embedment. Minimum Edge Distance. with filler plate full length of mullion. = 1/4" Tapcon 1¾" Minimum Embedment. Minimum Edge Distance. See Fig for Embedment Description Effective October 2014
SERIES CF450 INSTALLATION INSTRUCTIONS. SERIES CF450 1¾ x 4½ - B1. Fabrication for Panel Assembly. High Performance Non-Thermal Storefront System
SERIES CF450 INSTALLATION INSTRUCTIONS Fabrication for Panel Assembly High Performance Non-Thermal Storefront System Effective October 2014 www.cardcompro.com 1 2 www.cardcompro.com Effective October 2014
More informationSECTION C1 INSTALLATION INSTRUCTIONS
SECTION C1 SERIES CWW451T THERMALLY BROKEN FRONT GLAZED WINDOW WALL / STOREFRONT SYSTEM X 4 1 / for 1" GLAZING INSTALLATION INSTRUCTIONS EXTERIOR GLAZED Effective October 2014 www.cardcompro.com 1 INTERIOR
More informationStorefront Installation Guide
Storefront General Notes: 1. Check Contract Documents and Shop Drawings. Understand and clarify any Field Verify Notes and approvals of drawings and products to be familiar with the project. Installation
More information14000 I/O Series Flush Glaze. Fabrication and Installation Instructions
14000 I/O Series Flush Glaze Fabrication and Installation Instructions Last saved on 12/18/2009 Table of Contents GENERAL CONSTRUCTION NOTES...3 EXTRUDED ALUMINUM PARTS...4 ACCESSORIES...5 OVERVIEW...6
More informationINSTALLATION INSTRUCTIONS SIDELITE ASSEMBLY SERIES 900 TERRACE DOOR AND SERIES 925 PATIO DOOR
INSTALLATION INSTRUCTIONS SIDELITE ASSEMBLY SERIES 900 TERRACE DOOR AND SERIES 925 PATIO DOOR Phone: (800) 262-5151 Fax: (866) 262-3299 crlaurence.com usalum.com crl-arch.com 11M0292 HANDLING, STORAGE,
More informationDHS-500 IMPACT SYSTEM INSTALLATION MANUAL
DHS-500 IMPACT SYSTEM INSTALLATION MANUAL TABLE OF CONTENTS SECTION PAGE GENERAL NOTES 3 EXTRUSION & PARTS IDENTIFICATION 4-5 DETERMINE FRAME SIZE 6 FABRICATE VERTICAL MULLIONS & FILLERS 7-8 FABRICATE
More information4500 Series. Fabrication and Installation Instructions
4500 Series Fabrication and Installation Instructions E4500 Series July, 2017 Table of Contents GENERAL CONSTRUCTION NOTES... 3 EXTRUDED ALUMINUM PARTS... 5 ACCESSORIES... 7 OVERVIEW... 8 FRAME FABRICATION...
More information14000 Series. Fabrication and Installation Instructions
14000 Series Fabrication and Installation Instructions Revision May 2013 Table of Contents GENERAL CONSTRUCTION NOTES...3 EXTRUDED ALUMINUM PARTS...5 ACCESSORIES...8 OVERVIEW...10 FRAME FABRICATION...15
More information14000 Series. Fabrication and Installation Instructions
14000 Series Fabrication and Installation Instructions 14000 Series Revision December 01, 2009 Table of Contents GENERAL CONSTRUCTION NOTES... 3 EXTRUDED ALUMINUM PARTS... 4 ACCESSORIES... 7 OVERVIEW...
More informationINSTALLATION INSTRUCTIONS SERIES 487 CENTER GLAZED WITH 1-1/2" TRIM OFFICE PARTITIONS
INSTALLATION INSTRUCTIONS SERIES 87 CENTER GLAZED WITH -/" TRIM OFFICE PARTITIONS Phone: (800) -6 Fax: (800) 58-7 crlaurence.com usalum.com crl-arch.com M056_Rev_D SERIES 87 OFFICE PARTITIONS CENTER GLAZED
More informationINSTALLATION INSTRUCTIONS 2 x 4 1/2 for 1 Glass
INSTALLATION INSTRUCTIONS 2 x 4 1/2 for 1 Glass Deep pocket allows for direct anchor attachment to substrate without flat filler plate. 1/4 Ø perimeter anchor holes allows for direct anchor attachment
More informationGENERAL INSTALLATION GUIDELINES
1551 MT. ROSE AVENUE YORK PA 17403-2909 (717) 849-8100 GENERAL INSTALLATION GUIDELINES For Receptor Systems Approved 08/31/2018 Installation Guideline Disclaimer This document contains general installation
More informationYES 40 FS/FI Storefront System Installation Manual
Installation Manual 2014 YKK AP America Inc. is a subsidiary of YKK Corporation of America. TABLE OF CONTENTS Installation Notes... Page ii PARTS DESCRIPTION YES 40 FS Framing Members... Page 1 YES 40
More informationYES 45 TU Thermal Storefront System Installation Manual
Installation Manual 2004 YKK AP America Inc. is a subsidiary of YKK Corporation of America. TABLE OF CONTENTS Installation Notes........................................ Page ii PARTS DESCRIPTION Framing
More informationYES 600 Thermal Clip Storefront System Installation Manual
Installation Manual 2004 YKK AP America Inc. is a subsidiary of YKK Corporation of America. TABLE OF CONTENTS Installation Notes........................................ Page ii Frame Types............................................
More informationGENERAL INSTALLATION GUIDELINES
1551 MT. ROSE AVENUE YORK PA 17403-2909 (717) 849-8100 GENERAL INSTALLATION GUIDELINES For Receptor Systems Approved 9/29/2017 Installation Guideline Disclaimer This document contains general installation
More informationINSTALLATION INSTRUCTIONS
900 SERIES RIBBON WINDOW INSTALLATION INSTRUCTIONS 3056 Walker Ridge Dr. NW, Suite G Walker, MI 49544 800-866-2227 November 2016 www.tubeliteinc.com Page 1 TABLE OF CONTENTS GENERAL CONSTRUCTION NOTES...3-4
More informationFG-5100T STORMMAX INSTALLATION AND GLAZING MANUAL NOTE:
BuildingEnvelope R FG-5100T STORMMAX INSTALLATION AND GLAZING MANUAL NOTE: THE INSTALLATION DETAILS FOUND IN THIS PACKAGE ARE GENERIC AND ARE FOR REPRESENTATION ONLY WITH THE INTENT OF GIVING THE INSTALLATION
More informationNote: Installation and Glazing Manuals are product specific. FOR REVIEW ONLY! May 2015
Note: Installation and Glazing Manuals are product specific. FOR REVIEW ONLY! May 2015 Phone: 1-866-OLDCASTLE (653-2278) Web Address: www.oldcastlebe.com S E R I E S 6 0 0 0 X T - S T O R E F R O N T I
More informationYSG 40/50/50T Window Wall System Installation Manual
Installation Manual 2004 YKK AP America Inc. is a subsidiary of YKK Corporation of America. TABLE OF CONTENTS Installation Notes........................................ Page ii PARTS DESCRIPTION YSG 40
More informationELEPHANT DOOR SYSTEMS SERIES E1200
INSTALLATION INSTRUCTIONS ELEPHANT DOOR SYSTEMS SERIES E1200 Phone: (800) 262-5151 Fax: (866) 262-3299 crlaurence.com usalum.com crl-arch.com AVDB3096 03.13 TABLE OF CONTENTS SUBJECT PAGE GENERAL INSTALLATION
More informationInstallation Instructions
Installation Instructions 200 Series Curtainwall 3056 WALKER RIDGE DR. NW, SUITE G WALKER, MI 49544 800-866-2227 dependable@tubeliteinc.com Revised April 2014 dependable@tubeliteinc.com Page 1 TABLE OF
More informationYES 45 XT High Performance Thermal Storefront System
Dual Thermal Barrier ThermaBond Plus Pour & Debridge Technology Installation Manual 2015 YKK AP America Inc. is a subsidiary of YKK Corporation of America. TABLE OF CONTENTS Installation Notes... Page
More informationYWE 40 T Window Wall System Installation Manual
Installation Manual 2005 YKK AP America Inc. is a subsidiary of YKK Corporation of America. TABLE OF CONTENTS Installation Notes........................................ Page ii Frame Types............................................
More informationSeries Advanced and alternate. Installation Instructions
Series 5500 Advanced and alternate Installation Instructions Part NO. Y557 February 2013 TABLE OF CONTENTS SECTION S-5500 ADVANCED INSTALLATION INSTUCTIONS PAGE I. General Notes and Guidelines...... 3-4
More informationYES 45 FS/FI Storefront System Installation Manual
Installation Manual 2014 YKK AP America Inc. is a subsidiary of YKK Corporation of America. TABLE OF CONTENTS Installation Notes... Page ii PARTS DESCRIPTION YES 45 FS Framing Members... Page 1 YES 45
More informationINSTALLATION INSTRUCTIONS TRIFAB 451UT SCREW SPLINE ASSEMBLY TRIFAB 451UT. AUGUST, 2010 (Part No. 452T-CG-970) EC
AUGUST, 2010 (Part No. 452T-CG-970) EC 97904-31 1 INSTALLATION SCREW SPLINE ASSEMBLY Kawneer Company, Inc., 2010 INSTRUCTIONS 2 TABLE OF CONTENTS (452T-CG-970) AUGUST, 2010 These instructions show the
More informationYSD 400 Sliding Door System Installation Manual
System Installation Manual 2006 YKK AP America Inc. is a subsidiary of YKK Corporation of America. TABLE OF CONTENTS Installation Notes........................................ Page ii PARTS DESCRIPTION
More informationSERIES 5001 SLIDING GLASS DOOR PATIO DOORS INSTALLATION GUIDE
PATIO DOORS INSTALLATION GUIDE These instructions cover general installation conditions. Improper installation could affect your doors operation and warranty. Deviations from these instructions should
More informationNARROW, MEDIUM AND WIDE STILE, THERMASTILE AND DURASTILE. Installation Instructions
NARROW, MEDIUM AND WIDE STILE, THERMASTILE AND DURASTILE Installation Instructions PART Y015 JUNE 2016 Table of Contents Section 1. GENERAL NOTES AND GUIDELINES... 2. DOOR HARDWARE A. Locks B. Push/Pulls
More informationINSTALLATION INSTRUCTIONS
INSTALLATION INSTRUCTIONS Thermally Broken Framing and Door Installation SL-450TB (2" x 4-1/2" with 1" Glazing) & SL-600TB (2" x 6" with 1" Glazing) IMPORTANT: Read all instructions before beginning installation.
More informationSERIES 300 SINGLE HUNG WINDOW INSTALLATION
IMPORTANT INFORMATION: WHETHER IT BE LOCATION OR INSTALLATION TYPE, NOT ALL WINDOW TYPES CAN BE INSTALLED IN ALL AREAS OR WALL CONDITIONS. CONSULT YOUR LOCAL BUILDING CODE DEPARTMENT FOR ANY REGULATIONS
More informationSeries Sloped glazed Curtain wall. Installation Instructions
Series 5600 Sloped glazed Curtain wall Installation Instructions Part NO. Y308 February 2013 SECTION TABLE OF CONTENTS PAGE I. General Notes & Guidelines. 3-4 II. Gutter and Mullion Assembly.. 5 III. End
More informationINSTALLATION INSTRUCTIONS TRIFAB VG SCREW SPLINE ASSEMBLY TRIFAB VG 450 TRIFAB VG 451 TRIFAB VG 451T
INSTALLATION TRIFAB VG SCREW SPLINE ASSEMBLY TRIFAB VG 450 TRIFAB VG 451 TRIFAB VG 451T INSTRUCTIONS LITHO IN U.S.A. JANUARY KAWNEER COMPANY, INC., 2004 451-VG-970.01.04a PART NO. 451-VG-970 1 INSTALLATION
More informationYCW 750 IG Inside Glazed Curtain Wall System Installation Manual
Installation Manual 2014 YKK AP America Inc. is a subsidiary of YKK Corporation of America. TABLE OF CONTENTS Installation Notes... Page ii PARTS DESCRIPTION YCW 750 IG Framing Members... Page 1 to 3
More informationThermally Broken Framing and Door Installation
INSTALLATION INSTRUCTIONS Thermally Broken Framing and Door Installation IMPORTANT: Read all instructions before beginning installation. These instructions are provided to help prevent installation problems
More informationSERIES 300 SINGLE HUNG WITH FIN WINDOW INSTALLATION
IMPORTANT INFORMATION: WHETHER IT BE LOCATION OR INSTALLATION TYPE, NOT ALL WINDOW TYPES CAN BE INSTALLED IN ALL AREAS OR WALL CONDITIONS. CONSULT YOUR LOCAL BUILDING CODE DEPARTMENT FOR ANY REGULATIONS
More informationINSTALLATION INSTRUCTIONS ENTICE SERIES PREMIUM ENTRANCE SYSTEM EXTERIOR GLAZE
INSTALLATION INSTRUCTIONS ENTICE SERIES PREMIUM ENTRANCE SYSTEM EXTERIOR GLAZE Phone: (800) 421-6144 Fax: (800) 582-7501 crlaurence.com usalum.com crl-arch.com 11M0230 HANDLING, STORAGE, AND PROTECTION
More informationYCW 752 Outside Glazed Curtain Wall System Installation Manual
YCW 752 Outside Glazed Curtain Wall System Installation Manual 2007 YKK AP America Inc. is a subsidiary of YKK Corporation of America. TABLE OF CONTENTS Installation Notes........................................
More informationINSTALLATION INSTRUCTIONS 2 1/2 x 7 for 1 Glass
INSTALLATION INSTRUCTIONS 2 1/2 x 7 for 1 Glass Captured System 3010 Rice Mine Road, Tuscaloosa, Alabama 35406 1-800-772-7737 Fax 1-800-443-6261 www.coralind.com A Division of Coral Industries, Inc. B.G.
More informationYHS 50 FS Storefront System & Model 35H/50H Door Installation Manual
Installation Manual 2014 YKK AP America Inc. is a subsidiary of YKK Corporation of America. TABLE OF CONTENTS Installation Notes... Page ii PARTS DESCRIPTION YHS 50 Framing Members... Page 1 YHS 50 Accessories...
More informationSeries Exterior glazed curtain wall. Installation Instructions
Series 5500 Exterior glazed curtain wall Installation Instructions Part NO. Y550 November 2016 TABLE OF CONTENTS SECTION S-5500 SCREW SPLINE CURTAIN WALL PAGE I. General Notes and Guidelines.. 3-4 II.
More informationYHS 50 TU Storefront System & Model 35H Door Installation Manual
Installation Manual 2012 YKK AP America Inc. is a subsidiary of YKK Corporation of America. TABLE OF CONTENTS Installation Notes... Page ii PARTS DESCRIPTION YHS 50 TU Framing Members... Page 1 YHS 50
More informationStorefront Installation Guide INSTALLATION INSTRUCTIONS
STOREFRONT General Notes 1. Check contract documents and shop drawings, and understand and clarify any Field Verify Notes, approvals of drawings, and products required to be familiar with the project.
More informationTable of Contents. Typical elevation & cut lengths. General construction notes. General installation notes. Typical jamb assembly
c CD $ a c Q / / Table of Contents Page Description 1 Parts list 2 3 4 5 6 Typical elevation & cut lengths General construction notes General installation notes Typical jamb assembly Typical intermediate
More informationSeries 6000 THERMAL MULTI-PLANE INSTALLATION AND GLAZING MANUAL
Series 6000 THERMAL MULTI-PLANE INSTALLATION AND GLAZING MANUAL Note: Installation and Glazing Manuals are product specific. FOR REVIEW ONLY! TABLE OF ONTENTS General Information... p.2 Frame Fabrication...
More informationSERIES BW3250 BLAST WALL TABLE OF CONTENTS INSTALLATION INSTRUCTIONS GENERAL NOTES
I N S TA L L AT I O N I N S T R U C T I O N S BW3250 BLAST RESISTANT CURTAIN WALL Page 2 SERIES BW3250 BLAST WALL TABLE OF CONTENTS United States Aluminum PAGE GENERAL NOTES...2 and 3 FABRICATION...4 through
More informationSERIES 900 TERRACE DOOR WITH TRANSOM AND SIDELITES
INSTALLATION INSTRUCTIONS SERIES 900 TERRACE DOOR WITH TRANSOM AND SIDELITES Phone: (800) 262-5151 Fax: (866) 262-3299 crlaurence.com usalum.com crl-arch.com 11M0172_REV_A HANDLING, STORAGE, AND PROTECTION
More informationINSTALLATION INSTRUCTIONS SERIES 3600 SUNSHADE SYSTEM
INSTALLATION INSTRUCTIONS SERIES 3600 SUNSHADE SYSTEM Phone: (800) 262-5151 Fax: (866) 262-3299 crlaurence.com usalum.com crl-arch.com 11M0103 HANDLING, STORAGE, AND PROTECTION OF The following precautions
More informationNote: Installation and Glazing Manuals are product specific. FOR REVIEW ONLY! OCTOBER Phone: OLDCASTLE ( ) Web Address:
Note: Installation and Glazing Manuals are product specific. FOR REVIEW ONLY! TABLE OF CONTENTS General Information............................. Page 2 4 Outside Glaze Non Thermal...............................Page
More informationYCW 750 OG Outside Glazed Curtain Wall System Installation Manual
YCW 750 OG Outside Glazed Curtain Wall System Installation Manual 2004 YKK AP America Inc. is a subsidiary of YKK Corporation of America. TABLE OF CONTENTS Installation Notes........................................
More informationYOW 225 TU Window System
ThermaBond Plus Poured & Debridged Technology YOW 225 TU SYSTEM DESCRIPTION YOW 225 TU PERFORMANCE FEATURES 2-1/4 Overall Depth ThermaBond Plus Poured & Debridged Thermal Break Variations: Casement, Projected
More informationNote: Installation and Glazing Manuals are product specific. FOR REVIEW ONLY! FEBRUARY 2012
Note: Installation and Glazing Manuals are product specific. FOR REVIEW ONLY! Phone: 1-866-OLDCASTLE (653-2278) Web Address: www.oldcastlebe.com FG-1000 & FG-2000 INSTALLATION & GLAZING INSTRUCTIONS These
More informationSun Control-Solar Eclipse-Solar Shelf
Sun Control-Solar Eclipse-Solar Shelf Note: Installation and Glazing Manuals are product specific. FOR REVIEW ONLY! TABLE OF CONTENTS GENERAL INFORMATION Product Use...Page 3 Protection and Storage...Page
More informationINSTALLATION MANUAL STOREFRONT DOORS
INSTALLATION MANUAL STOREFRONT DOORS www.aluflam-usa.com SYSTEM DESCRIPTION - Extruded and filled aluminum framing, tested and approved by UL - 3-3/8 frame depth - Clear, fire-rated safety glazing - Door
More informationINSTALLATION INSTRUCTIONS
400T SERIES CURTAIN WALL INSTALLATION INSTRUCTIONS 3056 Walker Ridge Dr. NW, Suite G Walker, MI 49544 800-866-2227 October 2017 www.tubeliteinc.com Page 1 BLANK Page 2 www.tubeliteinc.com October 2017
More informationInstallation Instructions
Installation Instructions 1293 N. Harvey Mitchell Pkwy. Bryan, Texas 77803 800.444.1444 ph 979.823.1005 fax www.aswcommercial.com Simplifying Windows Complete Architectural CD Binder Inside B l as t I
More informationSERIES 406X. Installation Instructions. Place photography here. Don t go over grey area. (size w x h )
SERIES 406X Installation Instructions Place photography here. Don t go over grey area (size 7.9961 w x 7.4561 h ) Table of Contents Section 1. General Notes and Guidelines. 2. Parts Identification Charts
More informationHeavy Wall Applied Stop Tube Frame and Door Installation
INSTALLATION INSTRUCTIONS Heavy Wall Applied Stop Tube Frame and Door Installation Read all instructions before beginning installation. These instructions are provided to help prevent installation problems
More informationINSTALLATION INSTRUCTIONS. EnCORE CAPTURED & SSG SCREW SPLINE SHEAR BLOCK TYPE B LITHO IN U.S.A. JANUARY KAWNEER COMPANY, INC
INSTALLATION EnCORE CAPTURED & SSG SCREW SPLINE SHEAR BLOCK TYPE B INSTRUCTIONS LITHO IN U.S.A. JANUARY KAWNEER COMPANY, INC. 2004 175-970.01.04 PART NO. 175-970 INSTALLATION INSTRUCTIONS CONTENTS These
More informationSwing Door Installation Manual
Manual 20D/35D/50D 20DH/35DH 40M/50M 25FD 35XT 50XT 01-4000-03 2010 YKK AP America Inc. is a subsidiary of YKK Corporation of America. TABLE OF CONTENTS Installation Notes.......................................
More informationYCW 750 OG Outside Glazed Curtain Wall System Installation Manual
YCW 750 OG Outside Glazed Curtain Wall System Installation Manual 2012 YKK AP America Inc. is a subsidiary of YKK Corporation of America. TABLE OF CONTENTS Installation Notes... Page ii PARTS DESCRIPTION
More informationSeries 406 storefront. Installation Instructions
Series 406 storefront Installation Instructions Part NO. Y016 February 2013 Series 406 Installation Instructions TABLE OF CONTENTS Section I GENERAL NOTES Page 1 II PARTS IDENTIFICATION Page 2-3 III FABRICATION
More informationInstallation Instructions
Installation Instructions 400 Series Curtainwall 3056 WALKER RIDGE DR. NW, SUITE G WALKER, MI 49544 800-866-2227 dependable@tubeliteinc.com Revised September 2014 dependable@tubeliteinc.com Page 1 TABLE
More informationTCR 250 THERMAL COMPOSITE RIBBON WINDOW
CORRECT DRO OVER THE 5/8" 1" TOP OF HORIZONTAL 1 1/4" 2 3/8" SEAL THIS ACCESS HOLE ONLY 2 3/4".191 DIA. TAP HOLE FOR #14 SCREW DETAIL AT INCIDENTAL WATER APPLICATION STRAP ANCHOR DESIGNED ON A PER-JOB
More informationINSTALLATION INSTRUCTIONS. EnCORE CAPTURED & SSG SCREW SPLINE SHEAR BLOCK TYPE B. EnCORE FEBRUARY, 2012 EC PART NO.
FEBRUARY, 2012 1 INSTALLATION CAPTURED & SSG SCREW SPLINE SHEAR BLOCK TYPE B INSTRUCTIONS 2 FEBRUARY, 2012 INSTALLATION INSTRUCTIONS CONTENTS These instructions show the general installation sequence and
More informationINSTALLATION INSTRUCTIONS
MARCH, 2009 PART NUMBER 590-500 1 INSTALLATION INSTRUCTIONS 2 INDEX MARCH, 2009 INSTALLATION INSTRUCTIONS CONTENTS These instructions show the general installation sequence and procedure for typical installation.
More informationINSTALLATION INSTRUCTIONS. Thermal Entrances AA 250/AA 425 THERMAL DOOR WITH TRIFAB 601/601T FRAMING
JANUARY, 2014 1 INSTALLATION Thermal Entrances AA 250/AA 425 THERMAL DOOR WITH TRIFAB 601/601T FRAMING INSTRUCTIONS 2 FRAME ASSEMBLY JANUARY, 2014 601442 SHEAR BLOCK BALL BEARING NRP BUTT (FACTORY APPLIED
More informationYVS 400 TU Window System
YVS 400 TU SYSTEM DESCRIPTION YVS 400 TU PERFORMANCE FEATURES 4 Overall Depth ThermaBond Plus Poured & Debridged Thermal Break Variations: Single Hung, Double Hung & Fixed Windows 1 /8 & 1 1 /16 Glazing
More informatione-lite fabrication/assembly and Installation instructions
e-lite fabrication/assembly and Installation instructions Part NO. YWLS February 2013 TABLE OF CONTENTS SECTION PAGE I. General Notes and Guidelines.. 3-4 II. E-Lite Stick Built Channel Base Assembly...
More informationYHC 300 IG Inside Glazed Curtain Wall System Installation Manual
YHC 300 IG Inside Glazed Curtain Wall System Installation Manual 2007 YKK AP America Inc. is a subsidiary of YKK Corporation of America. TABLE OF CONTENTS Installation Notes........................................
More informationI n s t a l l a t i o n I n s t r u c t i o n s S E N T I N E L S E R I E S 1 50 SLIDING GLASS DOORS
I n s t a l l a t i o n I n s t r u c t i o n s S E N T I N E L S E R I E S 1 50 SLIDING GLASS DOORS Page 2-9: Installation Instructions, Figures 1, 2, & 3 Page 10-12: Figures A-1, A-2, & A-3: Installation
More informationYHC 300 SSG Structural Silicone Glazed Curtain Wall System Installation Manual
YHC 300 SSG Structural Silicone Glazed Curtain Wall System Installation Manual 2007 YKK AP America Inc. is a subsidiary of YKK Corporation of America. TABLE OF CONTENTS Installation Notes........................................
More informationFlushglaze For Framed Openings and Horizontal Panels. Window System Installation Guide
Flushglaze 4500 For Framed Openings and Horizontal Panels Window System Installation Guide January 2017 BENCHMRK Welcome to Kingspan, global leaders in the design and manufacture of insulated metal panels
More informationYSD 600 T/TH Sliding Door System Installation Manual
System Installation Manual 2006 YKK AP America Inc. is a subsidiary of YKK Corporation of America. TABLE OF CONTENTS Installation Notes........................................ Page ii & iii PARTS DESCRIPTION
More informationSeries 955 Tech Set storefront. Installation Instructions
Series 955 Tech Set storefront Installation Instructions Part NO. Y008 February 2013 TABLE OF CONTENTS SECTION PAGE I II III GENERAL NOTES AND GUIDELINES 1-2 PARTS IDENTIFICATION 3-5 DRILL JIGS 6-7 DRILL
More informationPocket Door Installation Instructions
Installation Instructions Before getting started: Read instructions thoroughly. Be sure that you have the necessary tools and materials before starting the installation. Consult your local building code
More informationSeries 526 Thermal impact storefront. Installation Instructions
Series 526 Thermal impact storefront Installation Instructions Part NO. Y021 February 2013 TABLE OF CONTENTS SECTION PAGE I. General Notes and Guidelines. 3 II. Parts Identification Chart.......4-8 III.
More informationDefinitions and Design Considerations... W-CR-2
General Information SECTION DIRECTORY Definitions and Design Considerations... W-CR-2 Combination Assembly Recommendations and Limitations Typical Sealant... W-CR-4 Single-Unit Opening... W-CR-4 Two-Way
More informationHeavy Wall Applied Stop Tube Frame and Door Installation
INSTALLATION INSTRUCTIONS Heavy Wall Applied Stop Tube Frame and Door Installation IMPORTANT: Read all instructions before beginning installation. These instructions are provided to help prevent installation
More informationAluminum Clad Wood Window 1/2 Reinforced Field Mulling and Stacking Supplement
Aluminum Clad Wood Window 1/2 Reinforced Field Mulling and Stacking Supplement 1 Aluminum Clad Wood Window 1/2 Reinforced Field Mulling and Stacking Supplement The following instructions are a supplement
More informationInstallation Manual. YSD 600 T/TH Sliding Door. YSD 600 T/TH Sliding Door System
YSD 600 T/TH Sliding Door System Installation Manual 2014 YKK AP America Inc. is a subsidiary of YKK Corporation of America. TABLE OF CONTENTS Installation Notes... Page ii & iii PARTS DESCRIPTION Framing
More informationINOVO 2-LITE SLIDING PATIO DOOR
INOVO 2-LITE SLIDING PATIO DOOR ASSEMBLY AND INSTALLATION INSTRUCTIONS IMPORTANT: READ THE INSTRUCTIONS AND FAMILIARIZE YOURSELF WITH THE DOOR PARTS AND PIECES BEFORE BEGINNING ASSEMBLY AND INSTALLATION.
More informationINSTALLATION INSTRUCTIONS IMPERVIA SLIDING PATIO DOOR WITH FINS
2008 Pella Corporation Part Number: 803V0101 INSTALLATION INSTRUCTIONS IMPERVIA SLIDING PATIO DOOR WITH FINS Installation Instructions for Typical Wood Frame Construction. These instructions were developed
More informationINSTALLATION INSTRUCTIONS Frames and Entrance Doors
INSTALLATION INSTRUCTIONS Frames and Entrance Doors J 3010 Rice Mine Road, Tuscaloosa, Alabama 35406 1-800-772-7737 Fax 1-800-443-6261 www.coralind.com A Division of Coral Industries, Inc. FRAMES and ENTRANCES
More informationInstallation Guidelines For Quaker Window Products Aluminum flange fin sub sill & receptor system using a T mulled twin window unit.
Installation Guidelines For Quaker Window Products Aluminum flange fin sub sill & receptor system using a T mulled twin window unit. Installer: Read these instructions completely before starting any installation.
More informationBuildingEnvelope Oldcastle ( ) -
BuildingEnvelope 1-866-Oldcastle (653-2278) - www.obe.com RELIANCE -LT CURTAIN WALL 2" X 7-1/2" / POLYAMIDE PRESSURE PLATE / 1" GLAZING Elev-Reliance-LT-750-PolyPP H0042-Steel-Anchor H5021-ShrBlk-Anchors
More informationINSTALLATION INSTRUCTIONS SERIES 8000 SINGLE HUNG WINDOW BLOCK OR FIN FRAME
INSTALLATION INSTRUCTIONS SERIES 8000 SINGLE HUNG WINDOW BLOCK OR FIN FRAME Phone: (800) 262-5151 Fax: (866) 262-3299 crlaurence.com usalum.com crl-arch.com 11M0166 HANDLING, STORAGE, AND PROTECTION OF
More informationSeries 7600 Installation Instructions Aluminum Multi-Slide Door (Pocketing)
Series 7600 Installation Instructions Aluminum Multi-Slide Door (Pocketing) Things to Know Before You Start Things to Know Before You Start Removal of Old Fenestration Products Ensure any old fenestration
More informationSeries 525 impact storefront. Installation Instructions
Series 525 impact storefront Installation Instructions Part NO. Y020 February 2013 SECTION I GENERAL NOTES II PARTS IDENTIFICATION III FABRICATION A. DRILLING TEMPLATE (SCREW SPLINE VERTICALS) B. DRILLING
More informationSERIES 8100 FIXED WINDOW BLOCK OR FIN FRAME
INSTALLATION INSTRUCTIONS SERIES 8100 FIXED WINDOW BLOCK OR FIN FRAME Phone: (800) 262-5151 Fax: (866) 262-3299 crlaurence.com usalum.com crl-arch.com 11M0105 HANDLING, STORAGE, AND PROTECTION OF The following
More information4-lite Patio Door. Installation Instructions
4-lite Patio Door Installation Instructions IMPORTANT: Read the instructions and familiarize yourself with the door parts and pieces before beginning assembly and installation. Note: Only the 5-0 x 6-8
More informationRead guide from beginning to end before starting installation. Read all warnings and cautions during unit installation.
Installation Guide for E-Series/Eagle High-Performance Mullion Windows with LVL Reinforcement and Installed Using Type B Clips Thank you for choosing Andersen. Instructions are for typical, new wood-framed
More information1/4 FRAMELESS DOOR WITH INLINE PANEL 1413A-1713A-1813A
1/4 FRAMELESS DOOR WITH INLINE PANEL 1413A-1713A-1813A F AB GLASS AND MIRROR www.fabglassandmirror.com Call: +1 888-474-2221 Fax: (614)-334-4919 Office Timing: 8:30-18:00 EST info@fabglassandmirror.com
More information3-LITE PATIO DOOR INSTALLATION INSTRUCTIONS
3-LITE PATIO DOOR INSTALLATION INSTRUCTIONS IMPORTANT: Read the instructions and familiarize yourself with the door parts and pieces before beginning assembly and installation. TOOLS NEEDED: Tape Measure
More informationPIVOT DOOR 3400P INSTALLATION INSTRUCTIONS
Table of Contents I. Tools, Sealant Requirements, Anchor Recommended Table...1 II. Opening, Frame & Panel Verification...2-3 III. Frame Assembly...4 IV. Frame Installation...5-7 V. Glazing Instructions...8
More informationSliding Glass Door Assembly and Installation Guide
Sliding Glass Door Assembly and Installation Guide Index Door System Components and Hardware The following components are needed to complete the installation of your Sliding Patio Door unit. Check all
More information675 Quick N Stall Neo Angle Framed Hinge Shower Enclosure
INSTALLATION INSTRUCTIONS 675 Quick N Stall Neo Angle Framed Hinge Shower Enclosure Call Technical Dept @ 1-800-452-2726 QCI1003 Page 1 of 9 Certified 10/01/09 INSTALLATION NOTES: Unpack your unit carefully
More informationSTACKING MULTI-SLIDE DOOR SYSTEM INSTALLATION INSTRUCTIONS
STACKING MULTI-SLIDE DOOR SYSTEM INSTALLATION INSTRUCTIONS 1290363 Revision 1 12/16 Page 1 Weather Shield Mfg., Inc. NOTICE CAUTION! Failure to install and maintain our product according to these instructions
More informationAssembly and Installation Instructions Section 1
Assembly and Installation Instructions Section 1 March 2013 PART NO. YS57 EFCO 2012 Page 2 Series 5500 XTherm Curtain Wall Assembly and Installation Instructions SECTION Note: Installation Instructions
More information