INFORMATION AND CONSULTATION

Size: px
Start display at page:

Download "INFORMATION AND CONSULTATION"

Transcription

1

2 INFORMATION AND CONSULTATION

3 INDEX WHO ARE WE? 04 WHAT DO WE OFFER? 05 INSTALLATION GUIDE AIR TERMINALS Ingesco PDC Lightning Rods 08 Ingesco PDC.E Lightning Rods 09 Ingesco PDC STREAM Lightning Rods 10 Franklin Lightning Rods 11 Special set Franklin + suport 11 FIXATION ACCESSORIES Head - Mast adaptor piece 12 Masts 12 Mast Anchor Set 13 Base Plate Support 14 DOWN-CONDUCTORS Braided Copper Cable 15 Steel Round Conductor 15 Copper Tape 15 CLAMPS Cable Clamping Backets 16 Folding Clamping Brackets 16 Clamping Brackets 16 Tape Clamping Brackets 17 Roof Conductor Support 17 Roof Conductor Holder for Flats Roofs 17 CONNECTION DEVICES Connection Sleeves 18 Connectors 18 Tape Connectors 19 Vx-1 Spark Gap 19 LIGHTNING STRIKE COUNTERS CDR-1 Lightning Strike Counter 20 CDR PCS Card 21 DOWN CONDUCTOR PROTECTION Protecction Tube 22 Guard For Tape Protection 22 GROUND ELECTRODE Sacrificial Anode 23 Graphite Electrode 23 Electrode - Grounding Rod 24 Electrode - Grounding Plate 25 Kit "Crow's Foot" 26 Quibacsol Mineral Compound 26 TEST JOINT Wall Mounted Test Joint 27 Test Joint In Box 27 Test Joint In Acces Box - Cable Model 28 Test Joint In Access Box - Tape Model 28 REGISTRY CASE Registry Case and Covers 29 INTERNAL PROTECCTION DEVICES Absorber - Transient Surge Protection 30 REFERENCES INDEX 31 page Index 03

4

5

6 INSTALLATION GUIDE CAPTURE SYSTEM INSTALLATION REQUIREMENTS: Ref The tip of the lightning rods must be located, at a minimum, two meters above the zone it protects (including antennas, cooling towers, ceilings and deposits). Install two or more down conductors for each installation of lightning rods. Ref The receiving antennas (TV, radio, telephone) must be connected by means of spark gaps to the down conductors of the lightning rod installations. Ref The coaxial cables of the antennas must be protected with a device against surges. Installation Guide DOWN CONDUCTOR Ref Ref Ref Ref Ref The metallic elements that rise above the roof should be connected to the closest down conductor. The trajectory of the down conductor must be as straight as possible and follow the shortest possible path, avoiding any abrupt layers or overhangings. In the layerings, the curvature of the radius are not to be inferior to 20 cm. The conducting cable must be placed outside of the building (whenever possible), avoiding the proximity of electrical or gas conductors. Ref It is recommended the grounding have a registry case available in order to perform periodic inspections. Ref The registry case (or, in its absence the conducting cable) must be provided with a system disconnecting switch that permits the disconnection of the grounding in order to measure its resistance. GROUNDING SYSTEM Ref The resistance of the grounding taken must be the lowest possible (less than 10 ohms). The value is measured on the ground insulted from all other elements of conductive nature. Ref Ref It is advisable to connect the grounding of the lightning rods with the general grounding system of the building it is designed to protect. It is recommended to add Quibacsol mineral composite to enhance ground conductivity. Ref Ref

7 INSTALLATION GUIDE DOWN CONDUCTORS The down conductors are designed to lead the lightning current from the capture devices to the ground. Each lightning rod must be connected to at least two down conductors (A and B). On buildings higher than 60m, four downconductors will be needed. These downconductors will be placed, wherever is possible, in the four corners of the building. Power A B The two down conductors are to be located on two different facades, whenever this is possible. EB GROUNDING INSTALLATION Grounding spikes Grounding electrode - Spike - Installation Guide Crow's foot grounding Bare braided copper cable Grounding plate Filler soil Quibacsol Natural soil 07

8 AIR TERMINALS INGESCO PDC LIGHTNING RODS GUARANTEE Lightning rod with non-electronic ESE (Early Streamer Emission) system, standardized according norms UNE and NFC Y E A R S Adaptable to all types of buildings. Application standards: UNE NFC EN /1 EN Product certification num. ES issued by the certification entity Bureau Veritas International. Manufactured in AISI 316L stainless steel and PA66 polyamide. 100 % EFFICIENCY, maximum durability. Does not need an external power supply. Air terminals Photo Mod. PDC 6.4 (Ref ) Guarantee of electrical continuity and operation after lightning strike, in any atmospheric conditions. MODELS / PROTECTION LEVELS : PDC 3.1 PDC 3.3 PDC 4.3 PDC 5.3 PDC 6.3 PDC INGESCO Lightning Rod 598 Mod. PDC Top View Mod. PDC º Reference W eight µs 25 µs 34 µs 43 µs 54 µs 60 µs LEVEL I 35 m 45 m 54 m 63 m 74 m 80 m LEVEL II 43 m 54 m 63 m 72 m 83 m 89 m LEVEL III 54 m 65 m 74 m 84 m 95 m 102 m LEVEL IV 63 m 75 m 85 m 95 m 106 m 113 m Protection radii calculated according to: Norm UNE & NFC (These radii of protection have been calculated according to an altitude difference of 20 m. between the end of the lightning rods and the considered horizontal plane). 20 Measurements in mm.

9 SISTEMAS AIR TERMINALS DE CAPTACIÓN INGESCO PDC.E LIGHTNING RODS Lightning rod with electronic ESE (Early Streamer Emission) system, standardized according norms UNE and NFC Adaptable to all types of buildings. Application standards: UNE NFC EN /1 EN Product certification num. ES issued by the certification entity Bureau Veritas International. Made of AISI 316 stainless steel. 100 % EFFICIENCY, maximum durability. Does not need an external power supply. Guarantee of electrical continuity and operation after lightning strike, in any atmospheric conditions. MODELS / PROTECTION LEVELS: Air terminals MODEL PDC.E 15 PDC.E 30 PDC.E 45 PDC.E 60 Photo Mod. PDC.E 60 (Ref ) Reference W eight µs 30 µs 45 µs 60 µs LEVEL I 35 m 50 m 65 m 80 m LEVEL II 43 m 59 m 74 m 89 m 16 LEVEL III 54 m 70 m 86 m 102 m LEVEL IV 63 m 81 m 97 m 113 m 412 Protection radii calculated according to: Norm UNE & NFC (These radii of protection have been calculated according to an altitude difference of 20 m. between the end of the lightning rods and the considered horizontal plane) Measurements in mm.

10 AIR TERMINALS INGESCO PDC STREAM LIGHTNING RODS DESCRIPCIÓN : GUARANTEE Lightning rod with electronic ESE (Early Streamer Emission) system, standardized according norms UNE and NFC E A Y R S Adaptable to all types of buildings. Application standards: UNE NFC EN /1 EN Product certification num. ES issued by the certification entity Bureau Veritas International. Made of AISI 316 stainless steel. 100 % EFFICIENCY, maximum durability. Does not need an external power supply. Air terminals Photo Mod. STREAM-60 (Ref ) Guarantee of electrical continuity and operation after lightning strike, in any atmospheric conditions. MODELS / PROTECTION LEVELS : MODEL STREAM-15 STREAM-30 STREAM-45 STREAM-60 Reference Weight µs 30 µs 45 µs 60 µs LEVEL I 35 m 50 m 65 m 80 m 18 LEVEL II 43 m 59 m 74 m 89 m LEVEL III 54 m 70 m 86 m 102 m 788 LEVEL IV 63 m 81 m 97 m 113 m Protection radii calculated according to: Norm UNE & NFC (These radii of protection have been calculated according to an altitude difference of 20 m. between the end of the lightning rods and the considered horizontal plane). Measurements in mm

11 AIR TERMINALS FRANKLIN LIGHTNING RODS Ref Multiple Franklin Ref External protection of structures against lightning. EN Made of AISI 316L stainless steel or copper. Models with adaptor part included, in versions for 50 mm 2 cables (or 8 mm. diameter bar) and 30 x 2 mm. tape. Ref Note: Consult for special measurements. Ref Ref Standard Models Reference Weight SIMPLE FRANKLIN - STAINLESS STEEL Ref Ref Ref Simple Franklin 275 SIMPLE FRANKLIN - COPPER MULTIPLE FRANKLIN - STAINLESS STEEL MULTIPLE FRANKLIN - COPPER Models Adaptable to Masts - CABLE version Reference Weight FR. MULTIPLE - STAINLESS STEEL / for 1'½" masts FR. MULTIPLE - STAINLESS STEEL / for 1'¼" masts ,35 1,20 FR. MULTIPLE - COPPER / for 1'½" masts ,40 FR. MULTIPLE - COPPER / for 1'¼" masts ,25 Models Aaptable to Masts - TAPE version Reference Weight Air terminals FR. MULTIPLE - STAINLESS STEEL / for 1'½" masts ,30 FR. MULTIPLE - STAINLESS STEEL / for 1'¼" masts ,10 41 Top View Multiple Franklin FR. MULTIPLE - COPPER / for 1'½" masts ,35 FR. MULTIPLE - COPPER / for 1'¼" masts ,15 SPECIAL SET FRANKLIN + SUPPORT 480 Ref Ref Set made up of Franklin lightning rods with copper tips (special measurements) plus flat base support, for the external protection of structures against lightning. 1 metre high supports for multiple or simple Franklin. Copper plated or galvanised support. EN º Copper Franklin set with copper plated support Ref ,50 Copper Franklin set with galvanised support... Ref ,60 Top view detail points Detailed view of the base

12 FIXATION ACCESSORIES HEAD - MAST ADAPTOR PIECE Necessary to connect the air terminal receiver to the mast. Ref Ref Ref Ref Facilitates the connection of the head to the conducting network. Available in two models: for connection to cable or rod conductive networks and for connection to 30x2 mm. tape conductive networks. EN EN /1 Made of Cu/Zn alloy (brass). Ref Ref Ref Stainless steel hardware. Front View Mod. 1'½" for Cable Mod. 1'½" for tape M8 MODELS Model for Cable Model for Tape (according to mast's ) Reference Weight Reference Weight Fixation accessories Ref M8 80 Ref '' inches ' ¼" inches ' ½" inches " inches MASTS 3 and 6 meter masts. Ref ,8 to 8,6 m. telescopic masts in connectable sections. 5, 8 and 9 m. telescopic masts in connectable sections with internal joint. Ref Models made of hot galvanized steel or stainless steel. Enquire about manufacturing of special dimensions. Ref STAINLESS STEEL Reference Weight 3 m. in 1'½" ,00 6 m. in 2 sections of 1'½" , M12 6 m. mast with internal union HOT GALVANIZED STEEL Reference Weight 3 m. in 1'¼" ,75 3 m. in 1'½" ,00 6 m. in 2 sections of 1'¼" ,80 6 m. in 2 sections of 1'½" , TELESCOPE IN STEEL GALVANIZED Reference Weight 40 Telescopic mast of 5,8 m. 47 5,8 m. 2 sections '¼'' 7,6 m. 3 sections '¼'' ,00 30,20 8,6 m. 3 sections '¼'' ,23 8 m. 3 sec. 2'' + 1'½'' + 1'¼'' stainless steel inside union ,80 9 m. 3 sec. 2'' + 1'½'' + 1'¼''' stainless steel inside union ,90

13 FIXATION ACCESSORIES MAST ANCHOR SET DESCRIPCTION : x 2 x 2 Useful for vertical fastening of masts to various structures. Permits fastening 1'½" and 2" tubes. Consult for other measurements. Suppliable in Work, Plate or Double anchor versions. Ref Ref Ref Set of two pieces made of hot galvanized steel. x 2 x 2 x 2 Ref Ref Ref MASONRY AND PLATE MODEL 1' ½" MODEL 2" ANCHORING Reference Weight Reference Weight x 2 x 2 Ref Ref Ref x 2 x 2 Ref Ref Ref WORK 15 cm ,80 WORK 30 cm , ,40 WORK 60 cm , ,40 WORK 100 cm , ,80 PLATE 15 cm , ,00 PLATE 15 cm. Inverted ,80 PLATE 30 cm , ,40 PLATE 60 cm , ,90 PLATE 100 cm , ,00 DOUBLE ANCHORING Reference Weight DOUBLE ANCHOR CLAMP 1'½" - 1'½" ,00 DOUBLE ANCHOR CLAMP 1'½" - 1'¼" ,80 DOUBLE ANCHOR CLAMP 1'½" - 2" ,20 DOUBLE ANCHOR CLAMP 2" - 2" ,40 DOUBLE ANCHOR CROSS CLAMP 1'½" - 1'½" ,00 Fixation accessories OTHER ANCHORINGS AND COMPLEMENTS Reference Weight ANCHORING PLATE ,70 HIP ROOF ANCHOR ,75 Work Anchor 30 cm. Plate Anchor 30 cm. Plate Anchor 15 cm Double Anchor 1'½"-1'½" Work Anchor 100 cm. Hip Roof Anchor

14 FIXATION ACCESSORIES BASE PLATE SUPPORT Mod. 1'½" 48 Flat base support for horizontal surfaces for tube fastening, available for 1'¼", 1'½" and 2" tubes. Base plate support for fixing 3 m high 1½" masts on horizontal surfaces Support for simple or multiple Franklin. Manufactured in hot dip galvanised steel or copper plated steel. Ref BASE PLATE SUPPORT Reference Weight Fixation accessories Ref Ref Top View Mod. 1'½" int. 1'½" with Double Anchor Clamps 1'½" - 1'¼" ,50 1'½" with Double Anchor Clamps 1'½" - 1'½" ,70 1'½" with Double Anchor Clamps 1'½" - 2" ,90 2" with Double Anchor Clamps 2" - 1'½" ,30 2" with Double Anchor Clamps 2" - 2" ,50 For 3 m. high 1'½" masts ,50 Galvanised support for Franklin ,75 Copper plated support for Franklin ,65 Top View 750 Ref Ref Top View 10

15 DOWN CONDUCTORS BRAIDED COPPER CABLE Braided bare electrolytic copper cable. NFC UNE EN /2 EN (only cables 50 mm²) Mainly applied as a down conductor for lightning protection and grounding systems. Cable section detail 35 mm² ( 7 mm) 50 mm² ( 8 mm) 70 mm² ( 10 mm) 95 mm² ( 11 mm) Ref Ref Ref Ref mm² of section... Ref /m 50 mm² of section... Ref /m 70 mm² of section... Ref /m 95 mm² of section... Ref /m STEEL ROUND CONDUCTOR Round conductor in accordance with EN Meets the requirements of VDE (IEC ). Manufactured in galvanised steel. Supplied in 125 m. coils. Down conductors Ref MODELOS : Rd 8 galvanised steel coil... Ref /m COPPER TAPE 30 x 2 mm. bare electrolytic copper bar, supplied in 3 m. bars. Coil of 30 x 2 mm. tinned electrolytic copper tape, supplied in 46 m coils (25kg). Ref NFC UNE EN /2 EN Mainly applied as a down conductor for lightning protection and grounding systems. 2 Tape cross section detail 30 x 2 mm Cu bar (3 m.)... Ref /m Coil of 30 x 2 mm tinned Cu bar (46 m.)... Ref /m

16 CLAMPS CABLE CLAMPING BACKETS Ref Ref DESCRIPTION: Ref Ref Ref Fastener clamps for mm² cross section cables. EN EN /4 Made of Cu/Zn alloy (brass), stainless steel hardware. Cable Clamp Br. 50 mm² Cable Clamp Br. 70 mm² Cable Clamp Br. 95 mm² Pre assembled models with different anchoring types in M6 and M8 sizes (plug, dowel screw, foot flange) MODELS: 40 M6 37,5 40 M M8 20 CLAMPING Cable 50 mm² Cable 70 mm² Cable 95 mm² BRACKET Reference Weight Reference Weight Reference Weight 40 Plug M Plug M Dowel Screw M Mod. Plug and Dowel Screw M-6 Mod. Plug and Dowel Screw M-8 Mod. Foot Flange Dowel Screw M Foot Flange Clamps Ref FOLDING CLAMPING BRACKETS Ref Ref DESCRIPTION: Fastening clamps for 50 mm² and 70 mm² section cable. Various models depending on the type of wall fixing : Dowel screw + metal plug Lag screw + plastic plug Manufactured in Zinc, with stainless steel fasteners M8 56 M8 Mod. Plug and Dowel Screw M-6 40 Mod. Plug and Dowel Screw M-8 MODELS: Folding clamping bracket double screw M8...Ref Dowel screw folding clamping bracket M8... Ref Plug folding clamping bracket M8... Ref INSULATING CLAMPING BRACKETS Ref DESCRIPTION: Ref Insulating clamps for 50 mm² section cable. Manufactured in Polyamide. Fixed to cable by clipping. 22 Model with wall fixing by means of a lag screw. 33 MODELS: 24 Insulator clamping bracket M8... Ref ,2 Dowel screw insulator clamping brackets M6... Ref ,4

17 CLAMPS TAPE CLAMPING BRACKETS Fastener clamps for 30x2 mm. cross section tape. Ref Ref Ref EN EN /4 Made of Cu/Zn alloy (brass), stainless steel hardware. Available with different anchoring types in M6 (plug, dowel screw, foot flange). M6 40 M6 37,5 5 M6 12 Mod. Plug M-6 Mod. Dowel Screw M-6 Mod. Foot Flange Plug M-6... Ref Dowel Screw M-6... Ref Foot Flange... Ref ROOF CONDUCTOR SUPPORT Ref DESCRIPTION: Adjustable support for mm wide lintel tiles. EN EN /4 Made of hot galvanized steel. Clamps Front View With fastener clamp for mm² cross section cables. 150 MODELS: 222 Cable CLAMP BRACKET 50 mm²... Ref Cable CLAMP BRACKET 70 mm²... Ref Cable CLAMP BRACKET 95 mm²... Ref ROOF CONDUCTOR HOLDER FOR FLAT ROOFS Ref DESCRIPTION: Concrete support with black polyethylene sheath. 76 EN EN /4 Top View Allows fixing round conductors 35 to 95 mm² on flat roofs. 133 MODELS: CONCRETE SUPPORT... Ref

18 CONNECTION DEVICES CONNECTION DEVICES DESCRIPCIÓN : Ref Ref Sleeves for the connection of mm² cross section cables. EN EN /1 Ref Ref Ref Made of Cu/Zn alloy (brass). Stainless steel hardware. M8 connection devices M8 60 Linear Connection model 50 x 50 mm² 10, Linear Connection model 50 x 95 mm² 100 'T' Connection model (1 piece) Section View Linear Connection model 50 x 50 mm² Section View Linear Connection model 50 x 95 mm² 82 'T' Connection model (2 pieces) 10,5 10, SLEEVES (by type of cables to connect) Reference W eight LINEAR CONNECTION 35 x 35 mm² LINEAR CONNECTION 35 x 50 mm² LINEAR CONNECTION 50 x 50 mm² LINEAR CONNECTION 50 x 70 mm² LINEAR CONNECTION 50 x 95 mm² LINEAR CONNECTION 70 x 70 mm² LINEAR CONNECTION 70 x 95 mm² LINEAR CONNECTION 95 x 95 mm² GROUND SLEEVES ELECTRODES E. GROUND ROD CONNECTION - 14 mm E. UNION CONNECTION - 18 mm SPECIAL Cable 50/70 mm² Cable 95 mm² SLEEVES Reference W eight Reference W eight Reference 'T' CONNECT. (1 Piece) Cross Connection model 'T' CONNECT. (2 Pieces) CROSS CONNECTION CONNECTORS Ref DESCRIPCIÓN : 60 Top View Cross Connector Connection fittings for 8-10 mm. round conductors and 50 mm² section cable. de sección. 40 Flat terminal for mm² section cable de sección. Ref Models manufactured in brass and hot dip galvanised steel. 40 Stainless steel (ref ) and galvanised steel fasteners. Adaptable Connector Top View 68 Ref FLAT TERMINAL... Ref RD 8-10 CROSS CONNECTOR... Ref ADAPTABLE CONNECTOR... Ref Side view Terminal Teeth

19 CONNECTION DEVICES TAPE CONNECTORS Ref Tape connectors specially designed for tapes 2 to 4 mm. thick and 30 mm. wide. EN EN /1 Ref Models made of copper or Cu/Zn alloy (brass), stainless steel hardware. 24 M6 18,5 M8 Front View Cross Coupler Cross Section Tape-Ground rod Coupler CROSS COUPLING FOR TAPE Reference W eight 50 In COPPER Top View Cross Coupler Ref Top View Tape-Ground rod Coupler TAPE-GROUND ROD COUPLER Reference W eight In Cu/Zn (Brass) VX-1 SPARK GAP Connection Devices Ref Indicated for the connection of TV and communications antennas and cathodic protection. EN /3 Maximum intensity 50 ka, wave type 10/350 µs. Response voltage 15kV =(1,2/50 µs) Ref It can be supplied with terminal connectors (sleeves) for tape or for mm² cross section cables. Stainless steel hardware Mod. VX VX-1... Ref VX-1 + Connection Sleeves for Cable 50 mm²... Ref VX-1 + Connection Sleeves for Cable 70 mm²... Ref VX-1 + Connection Sleeves for Cable 95 mm²... Ref VX-1 + Connection Sleeves for Tape... Ref Mod. VX-1 + Cable Sleeves Mod. VX-1 + Tape Sleeves

20 LIGHTNING STRIKE COUNTERS CDR-1 LIGHTNING STRIKE COUNTER Logs the lightning strikes which occur within the external lightning protection system. UNE NFC EN EN EN Range of Intensity: 1 ka (8/20 µs) ka (10/350 µs), according to EN /6 Valid for: Cable mm², Rod 8-12 mm, Tape 30x2 mm. An external power supply is not required for its operation. Ref Designed for installation in parallel. Lightning strike counters Resettable model. CDR-1... Ref Front View

21 LIGHTNING STRIKE COUNTERS CDR-11 Records the number of lightning strikes on a lightning protection system. Meets the requirements of the applicable standards: NFC UNE EN UNE-EN Ref Current range: 1 ka (8/20 µs) ka (10/350 µs), in accordance with EN Valid for: mm² cable, 8-12 mm diameter bar An external power supply is not required for its operation. Includes fasteners for fixing. Mounting system by wall fixing Top view Front view CDR Ref PCS CARD Lightning strike counters It detects and stores current spikes which circulate through the conductor. A support fixture is included for a 8 to 10 mm. diameter round cable. Ref PCS CARD... Ref Front View with the open support

22 DOWN CONDUCTOR PROTECTION PROTECTION TUBE Ref Ref x 3 Mechanical protector for down conductors of external lightning protection systems, placed at ground level. x 3 32 Suitable for the protection of external down conductors, as recommended by the UNE and NFC standards int. Length 3 m. Manufactured in galvanised steel. Ref contains 32 mm. diameter internal PVC tube. Includes 3 clamps, plugs and dowel screws. Down conductor protection Galvanized steel tube / PVC... Ref ,00 Galvanized steel tube... Ref ,80 GUARD FOR TAPE PROTECTION 80 Ref Mechanical protector for tape down conductors of external lightning protection systems, placed at ground level Suitable for the protection of external down conductors, as recommended by the UNE and NFC standards. Length 3 m. Model made of 1 mm. hot galvanized steel plate sheet. Masonry wall anchoring hardware included. 32 Detail View M8 MODELOS : TAPE GUARD... Ref ,60 x 8 Front View

23 GROUND ELECTRODE SACRIFICIAL ANODE M8 30 Ideal for protection against corrosion. 60 M8 Models manufactured in zinc or magnesium (model LC). Ref (Mod. HC) 40 Mod. HC 200 Ground resistivity: HC model (High Conductivity) ρ < 50 Ω m MC Model (Medium Conductivity) 50 < ρ < 200 Ω m LC model (Low Conductivity) 200 < ρ < 500 Ω m Includes connection coupling for 50 mm² cross section cable SACRIFICIAL ANODE Reference Weight Ref (Mod. LC) 66 Mod. LC 260 Ref (Mod. MC) 25 Mod. MC 200 mm long HC model mm long MC model mm long LC model Ground electrode GRAPHITE ELECTRODE Ref Graphite electrode with connection coupling (50 mm 2 ) cable) for grounding systems. Supplied in wrapping containing a solid graphite bar covered with graphite powder. Recommended for ground with high resistivity and/or rocky terrain. Long useful life due to minimal degradation by corrosion. 500 Graphite electrode: Longitude: 500 mm Electrical resistivity: Diameter: 50 mm 950 µω /cm Meets the requirements of the applicable standards: UNE NFC UNE-EN UNE-EN GRAPHITE ELECTRODE... Ref ,00 200

24 GROUND ELECTRODE ELECTRODE - GROUNDING ROD Ref Ref Very useful in any type of grounding (houses, antennas, machinery and instrumentation, etc.) 112 EN EN /2 Models made of hot galvanized steel, stainless steel or copperplated steel. Top extreme detail 1500 GROUNDING RODS WITH COUPLING TAB Reference Weight Bottom extreme detail Front View ,5 m. in GALVANIZED STEEL 18 mm ,27 1,5 m. in STAINLESS STEEL 18 mm ,22 COPPER-PLATED STEEL GROUNDING RODS Reference Weight Ground electrode Top extreme detail Mod. 18 y 14 mm. Ref Top extreme detail 2,5 m. long - 18 mm. 2 m. long - 18 mm. 2 m. long - 14 mm. 1,5 m. long - 18 mm. 1,5 m. long - 14 mm ,25 3,28 2,55 2,40 1,86 SPLICEABLE GROUNDING RODS Reference Weight 1,5 m. in GALVANIZED STEEL 18 mm ,19 END DRILL IRON HILTI TYPE STUCK TOOL with TE-Y connection (*) Bottom extreme detail Mod. 18 y 14 mm. Bottom extreme detail (*) Necessary jointly with an electric hammer drill for the placement of the spliceable grounding rods. Ref Ref Ref Perforating Tip Ref Ref

25 GROUND ELECTRODE ELECTRODE - GROUNDING PLATE Ideal for the installation of grounding systems with high resistance terrain. Models available made of Copper, Hot galvanized steel or Stainless steel*. *(The stainless steel model is recommended by INGESCO for use only in very humid, marine or highly corrosive environments). Ref Stainless steel hardware. Ref Complies with the requirements set forth in the standards (except Stainless steel model): UNE NFC Ref EN /2 EN Large contact surface. Ref It is recommended to add the Quibacsol mineral compound in the installation, and also a humidifying tube accessory for maintenance. Plate connection sleeve detail M GROUNDING PLATE - COPPER... Ref ,70 GROUNDING PLATE - GALVANIZED STEEL... Ref ,20 GROUNDING PLATE - STAINLESS STEEL... Ref ,30 HUMIDIFICATION TUBE... Ref Ground electrode Front View 500 Humidification Tube Side Lateral

26 GROUND ELECTRODE GROUND TERMINATION KIT - "CROW'S FOOT" Ref Very useful in any type of grounding, specially recommended for lightning protection systems. Tapes coupling detail UNE NFC EN /2 EN Models made of hot galvanized steel. Frontal View KIT "CROW'S FOOT" 1,5 m.... Ref ,50 KIT "CROW'S FOOT" 3 m.... Ref , Detail Views M Ground electrode 45º Tape thickness 30x3 QUIBACSOL MINERAL COMPOUND Mineral composite to improve conductivity to ground. With its use, low resistances are obtained in all types of groundings (houses, antennas, machinery and instrumentation, lightning rods, etc.) 255 Packaging made of recycled plastic, practical and easy to store. Ref QUIBACSOL - 10 PACKAGE... Ref , Top View

27 TEST JOINTS WALL MOUNTED TEST JOINT Ref Front View Mod. 2 Terminals 200 Grounding connection bar consisting of copper bar, insulators and terminal connectors. UNE NFC EN /1 EN Made of Cu (bar) and brass (terminals). Stainless steel hardware. Ref Top View Mod. 2 Terminals WALL MOUNTED TEST JOINT Reference Weight TERMINALS (Length: 200 mm.) TERMINALS (Length: 254 mm.) TERMINALS (Length: 308 mm.) TERMINALS (Length: 362 mm.) Top View Mod. 5 Terminals TEST JOINT IN BOX Test Joint 160 Wall mounted grounding test joint, consisting of Cu/Zn alloy (brass) manual disconnection system and 160x118x75 mm. PVC box, water resistant (IP 65). Stainless steel hardware. Specially made for 50 mm² cross section Cu cable down conductors. Fittings also available for connection of 70 and 95 mm² cross section cables and for copper tape 30x2 mm. down conductors. Ref Front View UNE NFC EN EN Refs TEST JOINT IN BOX... Ref FITTINGS FOR 70 mm² CABLE... Ref FITTINGS FOR 95 mm² CABLE... Ref FITTINGS FOR TAPE CONDUCTOR... Ref Ref Photo of Test Joint + Fittings

28 TEST JOINT TEST JOINT IN ACCESS BOX - CABLE MODEL Ref Grounding connection bar consisting of copper bar and connection terminals for 35 to 95 mm² cross section cables. UNE NFC EN /1 EN Made of Cu (Copper). Stainless steel hardware. Ref TEST JOINT IN ACCESS BOX - Cable Model Reference Weight Top View Mod. 2 Terminals Front View Mod. 2 Terminals TERMINALS (Length: 110 mm.) TERMINALS (Length: 110 mm.) TERMINALS (Length: 146 mm.) TERMINALS (Length: 182 mm.) Test joint Top View Mod. 5 Terminals TEST JOINT IN ACCESS BOX - TAPE MODEL Ref Grounding connection bar consisting of copper bar and connection terminals for 30x2 mm. copper tape. UNE NFC EN /1 EN Made of Cu (Copper). Stainless steel hardware. Ref Top View Mod. 3 Terminals 50 Front View Mod. 3 Terminals TEST JOINT IN ACCESS BOX - Tape Model Reference Weight 2 TERMINALS (Length: 140 mm.) TERMINALS (Length: 140 mm.) TERMINALS (Length: 185 mm.) TERMINALS (Length: 230 mm.) Top View Mod. 4 Terminals

29 REGISTRY CASE REGISTRY CASE AND COVERS Signage for ground connections. High strength antiskid inspection chambers and covers. Ref Ref Ref Models made of polypropylene or concrete. Ref Ref POLYPROPYLENE INSPECTION CHAMBERS Reference Weight Square chamber (30x30X30 cm.) ,00 PP square chamber and PVC cover (UNE-EN 124) ,60 Circular PP ( 20 cm.) Ref Ref / REGISTRY CASE AND COVERS Reference Weight Cast iron frame and cover ,95 Aluminium frame and cover ,22 CONCRETE REGISTRY CASE Reference Weight Square (33x33x23 cm.) ,00 Registry case DOWN CONDUCTOR SIGNALING Reference Weight Front View PP Square model Front View PP Circular model 245 Front View Concrete model 330 Grounding systems signaling PVC ,4 Grounding systems signaling aluminium , Top View PP Square model Top View PP Circular model Top View Concrete model Aluminum Frame + Cover Cast iron Frame + Cover Aluminum cover Cast iron cover

30 SURGE PROTECTION DEVICES ABSORBER TRANSIENT SURGE PROTECTION Protection against transitory surges of general electrical facilities connected to single-phase low voltage 230V mains power. Protector Type III (Fine protection). Suitable for protection of equipment intended to be connected to an electrical installation. Model MCD-E, includes a front jack for connecting equipment to the electrical grid. Ref Ref Technical specifications of the Absorber protectors: Nominal Voltage: U N = 230V AC (50Hz). Maximum working Voltage: U C = 275V AC (50Hz) Nominal discharge Intensity: I n (8/20 µs)= 5kA Maximum discharge Intensity: I max (8/20 µs)= 8kA Response time: t A < 25 ns Protection level: U P 1kV Nominal load current: I L = 16 A (MCD-E model) Surge protection devices Front View Mod. MCD Mod. MCD ABSORBER MCD... Ref ABSORBER MCD-E... Ref Front View Mod. MCD-E Mod. MCD-E 50

31 REFERENCES INDEX REF. CORPORATE NAME PAGE REF. CORPORATE NAME PAGE REF. CORPORATE NAME PAGE PROTECTION LINE INGESCO PDC INGESCO PDC INGESCO PDC INGESCO PDC INGESCO PDC INGESCO PDC PDC.E PDC.E PDC.E PDC.E PDC STREAM PDC STREAM PDC STREAM PDC STREAM SIMPLE FRANKLIN - STAINLESS STEEL SIMPLE FRANKLIN - COPPER COPPER FRANKLIN SET COPPER PLATED SUPPORT MULTIPLE FRANKLIN - STAINLESS STEEL MULTIPLE FRANKLIN - COPPER COPPER FRANKLIN SET GALVANISED SUPPORT FR. MULTIPLE - STAINLESS STEEL / FOR 1'½" MASTS FR. MULTIPLE - STAINLESS STEEL / FOR 1'¼" MASTS FR. MULTIPLE - COPPER / FOR 1'½" MASTS FR. MULTIPLE - COPPER / FOR 1'¼" MASTS FR. MULTIPLE - STAINLESS STEEL / FOR 1'½" MASTS FR. MULTIPLE - STAINLESS STEEL / FOR 1'¼" MASTS FR. MULTIPLE - COPPER / FOR 1'½" MASTS FR. MULTIPLE - COPPER / FOR 1'¼" MASTS 11 FIXATION ACCESSORIES GALVANISED SUPPORT FOR FRANKLIN ACCORDING TO MAST'S TAPE 1' ¼" INCHES ACCORDING TO MAST'S 1' ¼" INCHES ACCORDING TO MAST'S 1' ½" INCHES ACCORDING TO MAST'S 2" ½" INCHES ACCORDING TO MAST'S TAPE 1' ½" INCHES 1'½" ACCORDING TO MAST'S TAPE INCHES 1'¼" ACCORDING TO MAST'S TAPE 2" ½" INCHES ACCORDING TO MAST'S 1' INCHES ANCHORING WORK 30 CM ANCHORING WORK 60 CM ANCHORING WORK 100 CM ANCHORING PLATE 15 CM ANCHORING PLATE 30 CM ANCHORING DOUBLE CLAMP 1'½" - 1'½" ANCHORING PLATE 60 CM ANCHORING PLATE 100 CM ANCHORING DOUBLE CROSS CLAMP 1'½"-1'½" HIP ROOF ANCHOR ANCHORING DOUBLE CLAMP 2" - 2" ANCHORING DOUBLE CLAMP 1'½" - 2" ANCHORING DOUBLE CLAMP 1'½" - 1'¼" ANCHORING PLATE 15 CM DE 2" ANCHORING WORK 30 CM 2" ANCHORING PLATE 30 CM DE 2" ANCHORING WORK 60 CM 2" ANCHORING PLATE 60 CM 2" ANCHORING WORK 100 CM 2" ANCHORING PLATE 100 CM 2" ANCHORING PLATE ANCHORING PLATE 15 CM. INVERTED ANCHORING WORK 15 CM BASE SUPORT. 1'½" DOUBLE ANCHOR CLAMPS 1'½" - 1'½" BASE PLATE DOUBLE ANCHOR CLAMPS 2"- 2" BASE PLATE. 1'½" + DOUBLE ANCHOR CLAMPS 1'½" BASE PLATE. 1'½" + DOUBLE ANCHOR CLAMPS 1'½" - 1'¼" BASE PLATE. 2" DOUBLE ANCHOR CLAMPS 2"-1'½" BASE PLATE FOR 3M HIGH 1'½" MASTS HEAD MASTS HOT GALV. STEEL 6 M. IN 2 SEC. OF 1'½" HEAD MASTS STAINLESS STEEL 6 M. IN 2 SEC. OF 1'½" HEAD MASTS HOT GALVANIZED STEEL 3 M. IN 1'½" HEAD MASTS STAINLESS STEEL 3 M. IN 1'½" HEAD MASTS HOT GALV. STEEL 6 M. IN 2 SEC. OF 1'¼" 12 FIXATION ACCESSORIES HEAD MASTS HOT GALVANIZED STEEL 3 M. IN 1'¼" MASTS TELESC. STEEL GALV. 5,8 M. 2 SEC '¼" MASTS TELESC. STEEL GALV. 7,6 M. 3 SEC '¼" MASTS TELESC. STEEL GALV. 8,6 M. 3 SEC '¼" MTS. TELESC. STEEL GALV. 8 M. 3 SEC. 2"+ 1'½"+1'¼" U.INT MTS. TELESC. STEEL GALV. 9 M. 3 SEC. 2"+ 1'½"+1'¼" U.INT. 12 DOWN CONDUCTORS COPPER WIRE 35 MM COPPER WIRE 50 MM COPPER WIRE 70 MM COPPER WIRE 95 MM COPPER TAPE 30 X 2 MM. 3 M. LONG RD8 GALVANISED STEEL COIL COPPER TAPE 30 X 2 MM. 46 M. LONG. 15 CLAMPS CLAMPING BRACKET DOWEL SCREW M-6 70 MM CLAMPING BRACKET PLUG M-8 50 MM CLAMPING BRACKET PLUG M-6 50 MM CLAMPING BRACKET DOWEL SCREEW M-8 50 MM CLAMPING BRACKET FOOT FLANGE 50 MM CABLE CLAMP BRACKET 50 MM CLAMPING BRACKET PLUG M-8 95 MM CLAMPING BRACKET PLUG M-8 70 MM CLAMPING BRACKET PLUG M-6 95 MM CLAMPING BRACKET PLUG M-6 70 MM CLAMPING BRACKET DOWEL SCREEW M-8 95 MM CLAMPING BRACKET DOWEL SCREEW M-8 70 MM CLAMPING BRACKET FOOT FLANGE 95 MM CLAMPING BRACKET FOOT FLANGE 70 MM CLAMPING BRACKET DOWEL SCREW M-6 50 MM CLAMPING BRACKET DOWEL SCREW M-6 95 MM ROOF CONDUCTOR CLAMP BRACKET 70 MM ROOF CONDUCTOR CLAMP BRACKET 95MM TAPE CLAMPING BRACKETS DOWEL SCREW M TAPE CLAMPING BRACKETS PLUG M TAPE CLAMPING BRACKETS FOOT FLANGE INSULATOR CLAMPING BRACKET M CLAMPING BRACKET DOUBLE SCREW M DOWEL SCREW CLAMPING BRACKET M CLAMPING BRACKET PLUG FOLDING M DOWEL SCREW INSULATOR CLAMPING BRACKETS M CONCRETE SUPPORT 17 CONNECTION DEVICES SLEEVES LINEAR CONNECTION 50X50 MM "T" CONNECT. (1PIECE) 50/70 MM CROSS CONNECTION 50/70 MM E. GROUND ROD CONNECTION "T" CONNECT. (2 PIECE) 50/70 MM SLEEVES LINEAR CONNECTION 35X35 MM SLEEVES LINEAR CONNECTION 35X50 MM SLEEVES LINEAR CONNECTION 50X70 MM SLEEVES LINEAR CONNECTION 70X70 MM SLEEVES LINEAR CONNECTION 50X95 MM SLEEVES LINEAR CONNECTION 70X95 MM SLEEVES LINEAR CONNECTION 95X95 MM "T" CONNECT. (1 PIECE) 95 MM "T" CONNECT. (2 PIECE) 95 MM CROSS CONNECTION CABLE 95MM CROSS COUPLING FOR TAPE IN COPPER TAPE-GROUND ROD COUPLER E. UNION CONNECTION CONNECTORS FLAT TERMINAL RD 8-10 CROSS CONNECTOR ADAPTABLE CONECTOR VX VX-1 + CONNECTION SLEEVES FOR CABLE 50 MM VX-1 + CONNECTION SLEEVES FOR CABLE 70 MM VX-1 + CONNECTION SLEEVES FOR CABLE 95 MM VX-1 + CONNECTION SLEEVES FOR CABLE FOR TAPE 19 LIGHTNING STRIKE COUNTERS CDR CDR PCS CARD 21 DOWN CONDUCTOR PROTECTION GALVANIZED STEEL TUBE/PVC TAPE GUARD GALVANIZED STEEL TUBE 22 GROUND ELECTRODE HUMIDIFICATION TUBE GROUNDING PLATE - COPPER GROUNDING PLATE - STAINLESS STEEL GROUNDING PLATE - GALVANICED STEEL SACRIFICIAL ANODE 200 MM DE LONG HC MODEL SACRIFICIAL ANODE 600 MM DE LONG MC MODEL SACRIFICIAL ANODE 260 MM DE LONG LC MODEL GROUNDING RODS COUPLING 1,5 M. 18 MM COPPER PLATE GROUNDING RODS 1,5 M. 14 MM SPLICEABLE GROUNDING 1,5 M. 18 MM SPLICEABLE GROUNDING END DRILL IRON COPPER-PLATED GROUND. RODS 2,5 M. 18 MM COPPER PLATE GROUNDING RODS 2 M. 14 MM GROUNDING RODS COUPLING 1,5 M. 18 MM COPPER-PLATED GROUND. RODS 2,5 M. 18 MM COPPER-PLATED GROUND. RODS 1,5 M. 18 MM KIT "CROW'S FOOT" 1,5 M KIT "CROW'S FOOT" 3 M HILTI TYPE STUCK TOOL GRAPHITE ELECTRODE QUIBACSOL 26 TEST JOINTS WALL MOUNTED 2 TERMINALS (LENGTH:200 MM.) TERMINALS IN ACCES BOX (LENGTH: 110MM) TEST JOINT IN BOX WALL MOUNTED 3 TERMINALS (LENGTH:254 MM.) WALL MOUNTED 4 TERMINALS (LENGTH:308 MM.) WALL MOUNTED 5 TERMINALS (LENGTH:362 MM.) FITTINGS FOR 70MM 2 CABLE FITTINGS FOR 95MM 2 CABLE FITTINGS FOR TAPE CONDUCTOR TEST JOINT BOX - TAPE MODEL 2 TERMINALS TEST JOINT BOX - TAPE MODEL 3 TERMINALS TEST JOINT BOX - TAPE MODEL 4 TERMINALS TEST JOINT BOX - TAPE MODEL 5 TERMINALS TERMINALS IN ACCES BOX (LENGTH: 110 MM) TERMINALS IN ACCES BOX (LENGTH: 148 MM) TERMINALS IN ACCES BOX (LENGTH: 182 MM) 28 REGISTRY CASE CHAMBERS CIRCULAR PP CAST IRON FRAME AND COVER SQUARE REGISTRY CASE (33X33X23 CM) ALUMINIUM FRAME AND COVER PP SQUARE CHAMBER PVC SQUARE CHAMBER (30 X 30 X 30 CM) GROUNDING SYSTEMS SIGNALING PVC GROUNDING SYSTEMS SIGNALING ALUMINIUM 29 SURGE PROTECTION DEVICES ABSORBER MCD ABSORBER MCD-E 30 SYMBOLS USED Five year warranty against manufacturing defects. It complies with the maximum protection radii estalished in the current standarts Tested at the High Voltage Electrotechnical Laboratory LABELEC. Non electronica air terminal, it does not contain any consumable element, total electrical continuity guaranteed. ECOLOGICAL ESE lightning air terminal, no external power suply required. Will not expel any type of residual emission info the environment.

32

METRIC LIGHTNING PROTECTION PRODUCTS

METRIC LIGHTNING PROTECTION PRODUCTS Section 11 Metric Description... Page # 11.1 Taper Pointed Air Rods, Air Terminals & Attachments...270 11.2 Saddles & Attachments...271-272 11.3 s...273-275 11.4 Attachments...276-279 11.5 Clamps...280

More information

VBS TBS KTS BSS LFS UFS

VBS TBS KTS BSS LFS UFS VBS TBS KTS BSS LFS UFS TBS. Surge protection systems Order information and technical data Protection and isolating spark gaps Protection spark gap or isolating spark gap? Isolating spark gaps Protection

More information

Isolating Spark Gaps. Isolating spark gaps at an additional earth ring conductor. Isolating spark gaps for Ex zones

Isolating Spark Gaps. Isolating spark gaps at an additional earth ring conductor. Isolating spark gaps for Ex zones Isolating Spark Gaps Isolating spark gaps at an additional earth ring conductor Isolating spark gaps for Ex zones 187 Protective Spark Gaps For use at roof supports for overhead lines For indirect connection

More information

CONTINUING EDUC ATION

CONTINUING EDUC ATION 3 CONTINUING EDUC ATION FOR WISCONSIN ELECTRICIANS 2017 NEC Article 250 2 Hours WISCONSIN CONTRACTORS INSTITUTE N16 W23217 Stone Ridge Drive Suite 290 Waukesha, WI 53188 262-409-4282 www.wcitraining.com

More information

Wanco Electric & Machinery Pte Ltd. Cable Management Systems. Cable Trunking

Wanco Electric & Machinery Pte Ltd. Cable Management Systems. Cable Trunking Wanco Electric & Machinery Pte Ltd Cable Management Systems Cable Trunking About Wanco Wanco Electric and Machinery Pte Ltd is the leader in electrical construction materials. Through continued support

More information

Table and Furniture Base Fittings Plinth Adjusting Fittings

Table and Furniture Base Fittings Plinth Adjusting Fittings Adjusting screw with M8 or M thread Rigid, for glide inserts, steel thread Finish/Colour: Black, thread galvanized Version: With acceptance Ø30 mm Thread M8 650.22.381 M 650.22.382 Packing: 1 or 0 pcs.

More information

Earth Clamp / Ground Clamp Earth rod Clamp / Earthing rod Clamp Ground Clamp / Grounding Clamp

Earth Clamp / Ground Clamp Earth rod Clamp / Earthing rod Clamp Ground Clamp / Grounding Clamp Earth Clamp / Ground Clamp Earth rod Clamp / Earthing rod Clamp Ground Clamp / Grounding Clamp Copper alloy clamps are made from Bronze / Gunmetal / High Strength Copper Alloy body which give strong resistance

More information

Earthing of Electrical Devices and Safety

Earthing of Electrical Devices and Safety Earthing of Electrical Devices and Safety JOŽE PIHLER Faculty of Electrical Engineering and Computer Sciences University of Maribor Smetanova 17, 2000 Maribor SLOVENIA joze.pihler@um.si Abstract: - This

More information

7P Series - Surge Protection Device (SPD) Features 7P P P

7P Series - Surge Protection Device (SPD) Features 7P P P Features 7P.09.1.255.0100 7P.01.8.260.1025 7P.02.8.260.1025 SPD Type 1+2 Surge arrester range - single phase system / three phase system Surge arresters suitable in low-voltage applications in order to

More information

TZ-RD-1740 Rotary Dipole Instruction Manual

TZ-RD-1740 Rotary Dipole Instruction Manual TZ-RD-1740 17/40m Rotary Dipole Instruction Manual The TZ-RD-1740 is a loaded dipole antenna for the 40m band and a full size rotary dipole for the 17m band. The antenna uses an aluminium radiating section

More information

Outdoor Installation 2: Lightning Protection and Grounding

Outdoor Installation 2: Lightning Protection and Grounding Outdoor Installation 2: Lightning Protection and Grounding Training materials for wireless trainers This one hour talk covers lightning protection, grounding techniques and problems, and electrolytic incompatibility.

More information

1LG WALL MOUNTS - 1LG

1LG WALL MOUNTS - 1LG WM WALL MOUNTS - 1LG 1LG The Universal One-Legged Mount (1LG) may be the one and only mount that can be installed on any part of any building. This mount is designed for many types of antennas home, TV,

More information

OEM miniature resistance thermometer Models TR31-3 and TR31-K, thread-mounted

OEM miniature resistance thermometer Models TR31-3 and TR31-K, thread-mounted Electrical temperature measurement OEM miniature resistance thermometer Models TR31-3 and TR31-K, thread-mounted WIKA data sheet TE 60.31 Applications Machine building, plant and vessel construction Propulsion

More information

60Hz Ratings. Typical Applications. Features & Characteristics. Ratings

60Hz Ratings. Typical Applications. Features & Characteristics. Ratings The PCR is a solid-state device designed to simultaneously provide DC isolation and AC continuity/grounding when used with cathodically protected structures, such as pipelines, tanks, grounding systems,

More information

Ground Clamps Cable Tray

Ground Clamps Cable Tray commercial and industrial fittings: ing Fittings and Solderless Connectors Clamps Cable Tray Terminates ground wire to cable tray. For aluminum or copper conductors. 1 4 hex wrench tightens both tray and

More information

LC31L-BAT Link Coupler

LC31L-BAT Link Coupler Instruction Manual For the LC31L-BAT Link Coupler 09 March 2018 2012-2018 by Ralph Hartwell Spectrotek Services All rights reserved 2 RADIO FREQUENCY WARNING NOTICE If the LC31L-BAT is installed incorrectly

More information

6. Internal lightning protection

6. Internal lightning protection 6. Internal lightning protection 6.1 Equipotential bonding for metal installations Equipotential bonding according to IEC 60364-4- 41 and IEC 60364-5-54 Equipotential bonding is required for all newly

More information

CABLE TRAYS & STRUTS CATALOUGE

CABLE TRAYS & STRUTS CATALOUGE CABLE TRAYS & STRUTS CATALOUGE We are the Manufacturer for Copper Bonded Ground Rod and Contract Manufacturing Company for other products made from Brass, Copper, Gunmetal, Bronze, Cast Iron, Malleable

More information

5/16" Flange nut. Bolt Keeper Plate (8" Sq. SYS.) (3) 1/2" x 3" Hex head connector zinc plated bolt w/ washers and nut. Anchor 3" sq. 7 Ga.

5/16 Flange nut. Bolt Keeper Plate (8 Sq. SYS.) (3) 1/2 x 3 Hex head connector zinc plated bolt w/ washers and nut. Anchor 3 sq. 7 Ga. 2 1/2" x 2 1/2" x 10 Ga. 6" 5" 4" Variable Slipbase (8" Sq. SYS.) 5/16 Corner Bolt W/ nut 5/16" Flange nut Stub Insert (8" Sq. SYS.) Bolt Keeper Plate (8" Sq. SYS.) (3) 1/2" x 3" Hex head connector zinc

More information

Football Goals 7,32x2,44 m

Football Goals 7,32x2,44 m Football Goals 7,32x2,44 m 120x100 mm Professional aluminum football goals 7,32x2,44 m Made of special oval aluminum profile 120x100 mm with double reinforcing ribs. The main frame of the goal powder coated

More information

The innovation in lightning protection High-voltage-resistant, insulated HVI Conductor

The innovation in lightning protection High-voltage-resistant, insulated HVI Conductor The innovation in lightning protection High-voltage-resistant, insulated HVI Conductor www.dehn-international.com 2 High degree of safety due to controlled discharge of lightning currents Easy to install,

More information

Timing Antenna Installation

Timing Antenna Installation Timing Antenna Installation INTRODUCTION Tallysman designs and manufactures a range of antennas which are ideal for timing applications. These antennas are available with optional pre-filters to provide

More information

OptiLine 45 Floor boxes

OptiLine 45 Floor boxes OptiLine 45 Floor outlet boxes P89490 Type Colour Dimensions A/B/C (mm) Qty per pack Ref. No. Floor outlet box including mounting frames for Altira, trim frame with four quick-fix devices and lid with

More information

OEM miniature resistance thermometer Models TR31-3 and TR31-K, thread-mounted

OEM miniature resistance thermometer Models TR31-3 and TR31-K, thread-mounted Electrical temperature measurement OEM miniature resistance thermometer Models TR31-3 and TR31-K, thread-mounted WIKA data sheet TE 60.31 further approvals see page 10 Applications Machine building, plant

More information

GROUNDING. What is it? Al Lewey K7ABL. Disclaimer

GROUNDING. What is it? Al Lewey K7ABL. Disclaimer GROUNDING What is it? Al Lewey K7ABL Disclaimer Disclamier Mechanical Engineer with some electrical background My primary reference is References UP THE TOWER The Complete Guide to Tower Construction By

More information

Tools Needed. 8 per column: stainless steel or hot-dipped galvanized bolts. Mallet

Tools Needed. 8 per column: stainless steel or hot-dipped galvanized bolts. Mallet Structural VINYL PERGOLA SuperiorPlasticProducts.com Tools Needed Drill Safety Glasses 1 Hammer Drill & 1/2" Masonry Bit Tape Measure & Pencil Drill Bits 1/8" 1/4" 5/8" Level 8 per column: Ratchet & Sockets

More information

12-Port Antenna Frequency Range Dual Polarization HPBW Adjust. Electr. DT set by

12-Port Antenna Frequency Range Dual Polarization HPBW Adjust. Electr. DT set by 12-Port Antenna Frequency Range Dual Polarization HPB Adjust. Electr. DT set by R1 R2 Y1 Y2 Y3 Y4 698 803 824 894 1695 2690 1695 2690 1695 2690 1695 2690 X X X X X X 65 65 65 65 65 65 1.5 10 1.5 10 2.5

More information

12-Port Antenna Frequency Range Dual Polarization HPBW Adjust. Electr. DT set by

12-Port Antenna Frequency Range Dual Polarization HPBW Adjust. Electr. DT set by 12-Port Antenna Frequency Range Dual Polarization HPB Adjust. Electr. DT set by R1 R2 Y1 Y2 Y3 Y4 698 803 824 894 1695 2690 1695 2690 1695 2690 1695 2690 X X X X X X 65 65 65 65 65 65 2 12 2 12 2 14 2

More information

INTRODUCTION NUHAS OMAN QUALITY & RELIABILITY.

INTRODUCTION NUHAS OMAN QUALITY & RELIABILITY. INTRODUCTION Nuhas Oman LLC, an integral part of The Al Bahja Group of Companies, is a Quality producer of: HV, MV and LV Cables Enamelled Copper Wires Oxygen Free Continuous Cast Copper Wire Rods Drawn

More information

Installation Instructions for. Handrail Component System

Installation Instructions for. Handrail Component System Handrail STEP-BY-STEP Installation Instructions for Handrail Component System Rise in Inches Run in Inches 8 8.5 9 9.5 10 10.5 11 11.5 12 12.5 13 13.5 14 14.5 15 8.5 47 45 43 42 40 39 38 36 35 34 33 32

More information

SPECIFICATION No SS-135/ kv METAL OXIDE SURGE ARRESTERS WITHOUT GAPS

SPECIFICATION No SS-135/ kv METAL OXIDE SURGE ARRESTERS WITHOUT GAPS -1- INDEPENDENT POWER TRANSMISSION OPERATOR S.A. TNPRD/ SUBSTATION SPECIFICATION & EQUIPMENT SECTION June 2013 SPECIFICATION No 150 kv METAL OXIDE SURGE ARRESTERS WITHOUT GAPS I. SCOPE This specification

More information

Installation manual. For setting in concrete/on base plates - Panel height 1830

Installation manual. For setting in concrete/on base plates - Panel height 1830 1 Aluminium fencing and drive-in gates Installation manual For setting in concrete/on base plates - Panel height 1830 Aluclos system components: U10 Connecting U-bracket 1900 mm CL18/CL18.XL Half-height

More information

New Release - Latest Technology

New Release - Latest Technology New Release - Latest Technology Who is LPI? Lightning Protection International Pty Ltd (LPI) is a fully owned Australian manufacturer and supplier of direct strike lightning, surge & transient protection

More information

n Measurable displacements between n Linearity: max. ± 0.05 % n Housing diameter 12.9 mm n Service life: 10 8 movements

n Measurable displacements between n Linearity: max. ± 0.05 % n Housing diameter 12.9 mm n Service life: 10 8 movements Potentiometric Displacement Sensor Miniature design Model 8709 Code: Delivery: Warranty: 8709 EN ex stock 24 months Application Potentiometric displacement sensors are used for direct, precise measurement

More information

Wind Direction Transmitter - compact - GMR, analogue output xxx xxx

Wind Direction Transmitter - compact - GMR, analogue output xxx xxx THE WORLD OF WEATHER DATA - THE WORLD OF WEATHER DATA - THE WORLD OF WEATHER DATA Instruction for Use 021488/06/09 Wind Direction Transmitter - compact - GMR, analogue output - 4.3129.60.xxx 4.3129.80.xxx

More information

4-Port Antenna Frequency Range Dual Polarization HPBW Adjust. Electr. DT set by

4-Port Antenna Frequency Range Dual Polarization HPBW Adjust. Electr. DT set by 4-Port Antenna Frequency Range Dual Polarization HPB Adjust. Electr. DT set by R1 698 960 X 65 2 12 R2 698 960 X 65 2 12 4-Port Antenna 698 960/698 960 65 /65 15.5/15.5dBi 2 12 /2 12 T Type No. 80010901

More information

REPORT HOLDER: ISAIAH INDUSTRIES, INC. EVALUATION SUBJECT:

REPORT HOLDER: ISAIAH INDUSTRIES, INC. EVALUATION SUBJECT: 0 Most Widely Accepted and Trusted ICC ES Evaluation Report ICC ES 000 (800) 423 6587 (562) 699 0543 www.icc es.org ESR 1360 Reissued 08/2018 This report is subject to renewal 08/2019. DIVISION: 07 00

More information

Cisco Aironet 2.4-GHz/5-GHz 8-dBi Directional Antenna (AIR-ANT2588P3M-N)

Cisco Aironet 2.4-GHz/5-GHz 8-dBi Directional Antenna (AIR-ANT2588P3M-N) Cisco Aironet.4-GHz/5-GHz 8-dBi Directional Antenna (AIR-ANT588P3M-N) This document outlines the specifications for the Cisco Aironet AIR-ANT588P3M-N.4/5-GHz 8-dBi 3-Port Directional Antenna with N-connectors

More information

SECTION CABLE TRAYS

SECTION CABLE TRAYS SECTION 16139 CABLE TRAYS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 1 Specification Sections,

More information

TENNADYNE TD-160HP800

TENNADYNE TD-160HP800 TENNADYNE Aluminum with a PhD ASSEMBLY INSTRUCTIONS TD-160HP800 SPECIFICATIONS: Impedance: 50 Ohm nominal Bandwidth :1.8-30 MHz Length : 160 ft. Power : 8 KW Impulse 2400 W PEP SSB 800 W AM/FM/RTTY Connector

More information

4-Port Antenna Frequency Range Dual Polarization HPBW Adjust. Electr. DT Enhanced Sidelobe Suppression

4-Port Antenna Frequency Range Dual Polarization HPBW Adjust. Electr. DT Enhanced Sidelobe Suppression Frequency Range Dual Polarization HPB Adjust. Electr. DT Enhanced Sidelobe Suppression Y1 18dB 18dB Downtilt set by hand or by optional RCU (Remote Control Unit) X 65 2 14 X 65 2 14 4-Port Antenna / 65

More information

Specification for Lightning Sensor

Specification for Lightning Sensor Specification for Lightning Sensor Patent Pending November 24. 2003 Content: 1. General description 2. Functional description 3. Electrical connections. 4. Electrical specifications. 5. Mechanical specifications.

More information

OEM miniature resistance thermometer Models TR31-3 and TR31-K, thread-mounted

OEM miniature resistance thermometer Models TR31-3 and TR31-K, thread-mounted Temperature OEM miniature resistance thermometer Models TR31-3 and TR31-K, thread-mounted WIKA data sheet TE 60.31 further approvals see page 11 Applications Machine building, plant and vessel construction

More information

EXPOSED FASTENING SYSTEM WITH SCREWS OR RIVETS

EXPOSED FASTENING SYSTEM WITH SCREWS OR RIVETS External EXPOSED FASTENING SYSTEM WITH SCREWS OR RIVETS Parklex Facade may be installed using mechanical fasteners, such as screws or rivets. The panels are attached to vertical battens. In the event that

More information

SECTION SITE FURNISHINGS FOR CFCRT. 1. American Society for Testing and Materials (ASTM).

SECTION SITE FURNISHINGS FOR CFCRT. 1. American Society for Testing and Materials (ASTM). PART 1 - GENERAL 1.1 SECTION INCLUDES A. Benches. B. Trash receptacles. C. Bike storage. 1.2 REFERENCE STANDARDS A. Including but not limited to: 1. American Society for Testing and Materials (ASTM). 1.3

More information

TO O L K IT. Public Bike Repair

TO O L K IT. Public Bike Repair TO O L K IT Public Bike Repair The Dero Tool Kit includes all the necessary tools to perform most routine maintenance and adjustments on most bikes. All the tools are securely fastened with stainless steel

More information

GURANTEED TECHNICAL PARTICULARS OF BACK CLAMP FOR LT CROSS ARM

GURANTEED TECHNICAL PARTICULARS OF BACK CLAMP FOR LT CROSS ARM Technical Specification of Back Clamp for LT Cross Arm (MS) Back clamp for LT Cross Arm made out of 50 x 6mm MS Flat suitable for 8m X 300 Kg PSC poles. After fabrication the cross arm shall be painted

More information

LJ element beam for 10 or 12 meters INSTRUCTION MANUAL. CAUTION: Read All Instructions Before Operating Equipment

LJ element beam for 10 or 12 meters INSTRUCTION MANUAL. CAUTION: Read All Instructions Before Operating Equipment LJ-113 3 element beam for 10 or 1 meters INSTRUCTION MANUAL CAUTION: Read All Instructions Before Operating Equipment 308 Industrial Park Road Starkville, MS 39759 USA Tel: 66-33-9538 Fax: 66-33-6551 VERSION

More information

Omnidirectional Antenna Vertical Polarization Indoor and outdoor use

Omnidirectional Antenna Vertical Polarization Indoor and outdoor use db Omnidirectional Antenna and outdoor use 17 27 Omni 17 27 6 2dBi 8 41 N female Connector position Bottom or top 17 27 MHz SWR < 1.8 2 dbi Intermodulation IM < 15 dbc (2 x 4 dbm carrier) ertical 5 W (at

More information

2007 DEHN + SÖHNE / protected by ISO EXFS / 5392

2007 DEHN + SÖHNE / protected by ISO EXFS / 5392 2007 DEHN + SÖHNE / protected by ISO 16016 EXFS 100 11.12.07 / 5392 Ex Isolating Spark Gaps EXFS 100 (923 100) and EXFS 100 KU (923 101) 2007 DEHN + SÖHNE / protected by ISO 16016 Ex isolating spark gap

More information

PORTABLE UNITS BASKETBALL SCHELDE SUPER SAM MULTI-ADJUST

PORTABLE UNITS BASKETBALL SCHELDE SUPER SAM MULTI-ADJUST PORTABLE UNITS SCHELDE SUPER SAM MULTI-ADJUST Highest class unit with regulated projection (within range of 245-325 cm) equipped with SAM (Spring Assisted Mechanism) - unique solution which avails to set

More information

11-SDMS-03 REV. 02 SPECIFICATIONS FOR

11-SDMS-03 REV. 02 SPECIFICATIONS FOR 11-SDMS-03 REV. 02 SPECIFICATIONS FOR XLPE INSULATED POWER CABLES FOR RATED VOLTAGES FROM 15 KV UP TO 36 KV (U m ) This specification is property of SEC and subject to change or modification without notice

More information

RT-2632 OWNER'S MANUAL TAPERED TOWER. Call (800)

RT-2632 OWNER'S MANUAL TAPERED TOWER. Call (800) Lightning Rod kit with Aluminum Tapered Point, Mast Clamp, 8 Ground Rod & clamps,& leg Grounding Lug. Order wire separately below. LR-8400 #4 Ground Wire, order next longer length from tip of mast to ground

More information

American Electrical Institute

American Electrical Institute American Electrical Institute Oregon Electricians Continuing Education Grounding & Bonding (Article 250) 4 Hours American Electrical Institute PO Box 31131 Spokane, WA 99223 www.aeitraining.com Article

More information

Barofor Round System (polyester coated) Panels, Posts, Accessories

Barofor Round System (polyester coated) Panels, Posts, Accessories 1 Scope This Technical Data Sheet specifies the requirements for the Barofor Round System. The complete system exists of: Panels Posts Accessories such as fixation system and posts caps. Panels and posts

More information

Heavy duty profiles. Heavy loads with maximum stability. Profile general overview... p Heavy duty profiles... S Load data... p.

Heavy duty profiles. Heavy loads with maximum stability. Profile general overview... p Heavy duty profiles... S Load data... p. Heavy loads with maximum stability Profile general overview... p. 366 Heavy duty profiles... S. 368 Load data... p. 372 Connection techniques... p. 374 Accessories... p. 384 Heavy duty profiles 365 Heavy

More information

Outline. Grounding Washer, Electrical Equipment Bond (WEEB) Acme Cable Clips Acme Conduit Entry (ACE) Questions

Outline. Grounding Washer, Electrical Equipment Bond (WEEB) Acme Cable Clips Acme Conduit Entry (ACE) Questions www.we-llc.com Outline Grounding Washer, Electrical Equipment Bond (WEEB) Acme Cable Clips Acme Conduit Entry (ACE) Questions Bonding & Grounding Grounding Terms Equipment Grounding: The National Electrical

More information

INSTRUCTION MANUAL VB-66DX. 6-Meter 6-Element Beam. Preparation For Assembly. General Description

INSTRUCTION MANUAL VB-66DX. 6-Meter 6-Element Beam. Preparation For Assembly. General Description VB-66DX 308 Industrial Park Road Starkville, MS 39759 USA Ph: (662) 323-9538 FAX: (662) 323-6551 6-Meter 6-Element Beam INSTRUCTION MANUAL General Description The Hy-Gain Model 66DX is a full sized 6-

More information

Article 250 Grounding & Bonding

Article 250 Grounding & Bonding Article 250 Grounding & Bonding AMERICAN ELECTRICAL INSTITUTE N16 W23217 Stone Ridge Dr. Waukesha, WI 53188 855-780-5046 www.aeitraining.com DISCLAIMER NOTE: This course is APPROVED for continuing education

More information

Tested in accordance IEC Std: 60-1: 1989

Tested in accordance IEC Std: 60-1: 1989 Tested in accordance IEC Std: 60-1: 1989 LPI Product Offering Lightning Protection International Pty Ltd Lightning Protection International Pty Ltd is a fully owned Australian manufacturer and supplier

More information

Series 3401 lightning EMP protectors Gas discharge tube (GDT) technology up to 1.0 GHz

Series 3401 lightning EMP protectors Gas discharge tube (GDT) technology up to 1.0 GHz Series 3401 lightning EMP protectors Gas discharge tube (GDT) technology up to 1.0 GHz Description HUBER+SUHNER gas discharge tube protectors make the best of the traditional spark gap protection principle

More information

A. It is preferred that all submittals to be submitted electronically in PDF format.

A. It is preferred that all submittals to be submitted electronically in PDF format. June 20 2013, Rev 00 10 2800 Toilet, Bath, and Laundry Accessories PART 1. GENERAL 1.01 This Section includes: A. Toilet room accessories: 1.02 Submittals 1. Grab bars 2. Metal framed mirrors 3. Sanitary

More information

Material Packing Brown Grey Pine Black White

Material Packing Brown Grey Pine Black White RTA Connectors Minifix Zinc alloy For housing: 12 or 18 Bolt hole: Ø 7 or 8, depending on choice of connecting bolt Drilling distance B: Distance from centre of Minifix housing to shelf front edge (24

More information

Downtown Rack. Custom logo option available

Downtown Rack. Custom logo option available Custom logo option available Downtown Rack The Downtown Rack uses thick, square-tube construction that can t be cut with a pipe cutter. The extended width of the Downtown Rack makes for easy bike parking

More information

TFS / KFSU: Isolating spark gaps with plastic coating and 2 connections (Rd 10 mm) made of stainless

TFS / KFSU: Isolating spark gaps with plastic coating and 2 connections (Rd 10 mm) made of stainless LIGHTNING EQUIPOTENTIAL BONDING Isolating Spark Gap For lightning equipotential bonding For indirect connection/earthing of functionally isolated installation components when being affected by lightning

More information

6-Port Antenna Frequency Range Dual Polarization HPBW Adjust. Electr. DT set by

6-Port Antenna Frequency Range Dual Polarization HPBW Adjust. Electr. DT set by 6-Port Antenna Frequency Range Dual Polarization HPBW Adjust. Electr. DT set by R1 Y1 Y2 698 960 1710 2690 1710 2690 X X X 65 65 65 1 10 2.5 12 2.5 12 6-Port Antenna 698 960/1710 2690/1710 2690 65 /65

More information

SECTION ROOF ACCESSORIES. Display hidden notes to specifier. (Don't know how? Click Here)

SECTION ROOF ACCESSORIES. Display hidden notes to specifier. (Don't know how? Click Here) SECTION 07720 ROOF ACCESSORIES PART 1 GENERAL 1.1 SECTION INCLUDES Display hidden notes to specifier. (Don't know how? Click Here) A. Attachment clamp system for standing seam metal roofs. B. Attachment

More information

Wind Transmitter First Class / 141 / / 141 / 161

Wind Transmitter First Class / 141 / / 141 / 161 THE WORLD OF WEATHER DATA - THE WORLD OF WEATHER DATA - THE WORLD OF WEATHER DATA Instruction for Use 021436/01/07 Wind Transmitter First Class 4.3350.00.140 / 141 / 161 4.3350.10.140 / 141 / 161 ADOLF

More information

Freestanding Guardrail System. Operation & Maintenance Manual

Freestanding Guardrail System. Operation & Maintenance Manual Freestanding Guardrail System Operation & Maintenance Manual Specification Free Standing Edge Protection - System Specification General Description Our freestanding edge protection system is a cantilevered

More information

05 Pg A75-90.qxp 6/9/2008 9:36 AM Page A75 RACO Floor Boxes

05 Pg A75-90.qxp 6/9/2008 9:36 AM Page A75 RACO Floor Boxes 05 Pg A75-90.qxp 6/9/2008 9:36 AM Page A75 RACO Floor Boxes 05 Pg A75-90.qxp 6/9/2008 9:36 AM Page A76 A76 pq^ka^oapi=ommu=k^qflk^i=bib`qof`^i=`lab Δ déåéê~ä=^ééäáå~íáçåë o^`l=ñäççê=äçñéë=~êé=áçé~ääó=ëìáíéç

More information

micro DOUBLE TEN SWITCH

micro DOUBLE TEN SWITCH micro DOUBLE TEN SWITCH microham fax: +421 2 4594 5100 e-mail: support@microham.com homepage: www.microham.com 5 December, 2011 1 TABLE OF CONTENTS CHAPTER PAGE 1. IMPORTANT WARNINGS... 3 2. DESCRIPTION...

More information

INSTRUCTION MANUAL for MODEL TH6-DX "THUNDERBIRD" (389)

INSTRUCTION MANUAL for MODEL TH6-DX THUNDERBIRD (389) INSTRUCTION MANUAL for MODEL TH6-DX "THUNDERBIRD" (389) HY-GAIN ELECTRONICS CORPORATION, N. E. Hwy #6 at Stevens Creek, Lincoln, Nebraska 65801 Telephone 434-6331 INTRODUCTION Ely-Gain's new Model TH6-DX

More information

Miniature resistance thermometer Explosion-protected version Model TR34, thread-mounted

Miniature resistance thermometer Explosion-protected version Model TR34, thread-mounted Electrical temperature measurement Miniature resistance thermometer Explosion-protected version Model TR34, thread-mounted WIKA data sheet TE 60.34 Applications Machine building, plant and vessel construction

More information

Rain Gauge Smart Sensor (Part # S-RGA-M002, S-RGB-M002)

Rain Gauge Smart Sensor (Part # S-RGA-M002, S-RGB-M002) (Part # S-RGA-M002, S-RGB-M002) The Rain Gauge smart sensor is designed to work with HOBO Station loggers. The smart sensor has a plug-in modular connector that allows it to be added easily to a HOBO Station.

More information

Ameritron RCS-10 INTRODUCTION

Ameritron RCS-10 INTRODUCTION Ameritron RCS-10 INTRODUCTION The RCS-10 is a versatile antenna switch designed for 50-ohm systems. It handles high power, and sealed relays offer excellent life and connection reliability. It requires

More information

RADIO AND TELEVISION SATELLITE EQUIPMENT

RADIO AND TELEVISION SATELLITE EQUIPMENT ARTICLE 810 RADIO AND TELEVISION SATELLITE EQUIPMENT Introduction to Article 810 Radio and Television Satellite Equipment This article covers transmitter and receiver (antenna) equipment and the wiring

More information

SECTION METAL FABRICATIONS

SECTION METAL FABRICATIONS SECTION 05100 PART 1 - GENERAL 1.01 DESCRIPTION A. Section includes specifications for metal fabrications, including minimum requirements for fabricator, and galvanizing. 1.02 REFERENCE STANDARDS A. ASTM

More information

Ulltraclad Aluminium Cladding. Contents. 1.0 General Information Design Information Installation Information 7. 4.

Ulltraclad Aluminium Cladding. Contents. 1.0 General Information Design Information Installation Information 7. 4. Ulltraclad Aluminium Cladding Contents 1.0 General Information 2 2.0 Design Information 4 3.0 Installation Information 7 4.0 Maintenance 10 5.0 Health & Safety 10 1 1.0 General Information 1.1 Introduction

More information

PART MATERIALS. Section Fencing Materials. Description

PART MATERIALS. Section Fencing Materials. Description PART 03000 - MATERIALS Section 03010 - Fencing Materials Description 03010.00 Scope - This section consists of the test requirements, specifications and tolerances for barbed wire, woven wire and chain

More information

Khathij Industrial Fasteners

Khathij Industrial Fasteners Dear Sir/Madam, Khathij Industrial Fasteners This is Saqubar Sadique representing 'KHATHIJ INDUSTRIAL FASTENERS' from Chennai, India. We 'Khathij industrial fasteners' like to introduce us as a Stockist

More information

WIRELESS INSULATOR POLLUTION MONITORING SYSTEM

WIRELESS INSULATOR POLLUTION MONITORING SYSTEM SYSTEM OVERVIEW Pollution monitoring of high voltage insulators in electrical power transmission and distribution systems, switchyards and substations is essential in order to minimise the risk of power

More information

Standard Pole Mount Parabolic Antenna Mounting Instructions 3 ft. (90cm) & 4 ft. (120cm)

Standard Pole Mount Parabolic Antenna Mounting Instructions 3 ft. (90cm) & 4 ft. (120cm) 495 R Billerica Ave. N. Billerica, MA 01862 USA Tel: (978) 459-8800 Fax: (978) 459-3310 / 8814 www.radiowavesinc.com email: sales@radiowavesinc.com Standard Pole Mount Parabolic Antenna Mounting Instructions

More information

The new generation with system accessories. Made in Germany!

The new generation with system accessories. Made in Germany! 1 The new generation with system accessories. Made in Germany! For face, longitudinal and taper turning, thread-cutting. For machining steel, brass, aluminium and plastic. Mounting flange for fastening

More information

TENANT IMPROVEMENT 16 FEBRUARY WEST 27TH STREET, 4TH FLOOR 100% CD OWNER/BID ADD 1-03/08/2018

TENANT IMPROVEMENT 16 FEBRUARY WEST 27TH STREET, 4TH FLOOR 100% CD OWNER/BID ADD 1-03/08/2018 SECTION 055000 - PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections, apply

More information

3 Shielded Compact Ribbon (SCR) Wiremount Plug, XX, and Shell Kit, F200-XXX

3 Shielded Compact Ribbon (SCR) Wiremount Plug, XX, and Shell Kit, F200-XXX 3 Shielded Compact Ribbon (SCR) Wiremount Plug, 36110-3000XX, and Shell Kit, 36310-F200-XXX Instructions June 2007 78-9100-4282-5 General This instruction manual explains the method of assembling the 3M

More information

Pluggable connection describes the method used to connect an external conductor to a PCB, via a terminal connector and header

Pluggable connection describes the method used to connect an external conductor to a PCB, via a terminal connector and header Pluggable PCB terminals and headers Pluggable connection describes the method used to connect an external conductor to a PCB, via a terminal connector and header System features plug in system is simple

More information

Outdoor equipment. Barrier posts. Stainless steel. Barrier elements. Barrier poles. Outdoor equipment - pages

Outdoor equipment. Barrier posts. Stainless steel. Barrier elements. Barrier poles. Outdoor equipment - pages - pages 215-228 Bicycle stands / lean-on hoops Laundry drying stands Tree guards Litter bins Planters 215 Bicycle rack Sturdy and space-saving due to alternating high and low racks. Racks can be bolted

More information

Pre-Galv vs Post-Galv Specifications for Cable Containment Products

Pre-Galv vs Post-Galv Specifications for Cable Containment Products Pre-Galv vs Post-Galv Specifications for Cable Containment Products When specifying a suitable finish for cable containment products the term Hot-Dip Galvanised can be ambiguous and without the correct

More information

TENNADYNE. Aluminum with a PhD. Tennadyne ASSEMBLY INSTRUCTIONS MODEL: T Log Periodic Antennas SPECIFICATIONS:

TENNADYNE. Aluminum with a PhD. Tennadyne ASSEMBLY INSTRUCTIONS MODEL: T Log Periodic Antennas SPECIFICATIONS: TENNADYNE Aluminum with a PhD ASSEMBLY INSTRUCTIONS MODEL: T10-100224 SPECIFICATIONS: FREQUENCY COVERAGE 13-33 MHz FORWARD GAIN 6.1 dbd ½ POWER BEAMWIDTH 52 DEGREES F:B RATIO To 25 Db (Rises with frequency)

More information

SECTION - 3 EARTHING CLAMPS & FITTINGS

SECTION - 3 EARTHING CLAMPS & FITTINGS SECTION - 3 EARTHING CLAMPS & FITTINGS 78 EARTHING CONDUCTOR TO FLAT SURFACE TYPE ESS - SINGLE CONDUCTOR TYPE EST - TWIN CONDUCTOR Types ESS (single conductor) and EST (twin conductor) clamps are designed

More information

INSTRUCTION MANUAL ORDER NO. V3R MODEL V3R. Collinear Gain Vertical for MHz

INSTRUCTION MANUAL ORDER NO. V3R MODEL V3R. Collinear Gain Vertical for MHz ORDER NO. V3R MODEL V3R Collinear Gain Vertical for 216-225 MHz INSTRUCTION MANUAL General Description The new Hy-Gain V3R VHF antenna is a collinear 5/8-wave omnidirectional vertical antenna for the 216-225

More information

International Tube & Conduit Company Ltd. BRITISH STANDARD STEEL CONDUITS & FITTINGS

International Tube & Conduit Company Ltd. BRITISH STANDARD STEEL CONDUITS & FITTINGS International Tube & Conduit Company Ltd. BRITISH STANDARD STEEL CONDUITS & FITTINGS 1 ABOUT THE COMPANY VISION STATEMENT We strive to exceed our customers expectations through leading edge technologies

More information

AD5X. Low Cost HF Antennas & Accessories. Phil Salas - AD5X Phil Salas AD5X. Richardson, Texas

AD5X. Low Cost HF Antennas & Accessories. Phil Salas - AD5X Phil Salas AD5X. Richardson, Texas Low Cost HF Antennas & Accessories Phil Salas - AD5X ad5x@arrl.net PVC Tubing PVC pipe: Considers the inside diameter (ID) of the pipe. For PVC pipe (schedule 40): 1/2" PVC pipe has an ID of 0.6" and an

More information

ASSEMBLY AND INSTALLATION INSTRUCTIONS R , 12, 15, 17, 20, 30, 40 Meters (5/99) COMMUNICATIONS ANTENNAS

ASSEMBLY AND INSTALLATION INSTRUCTIONS R , 12, 15, 17, 20, 30, 40 Meters (5/99) COMMUNICATIONS ANTENNAS ASSEMBLY AND INSTALLATION INSTRUCTIONS R7000 10, 12, 15, 17, 20, 30, 40 Meters COMMUNICATIONS ANTENNAS 951465 (5/99) WARNING THIS ANTENNA IS AN ELECTRICAL CONDUCTOR. CONTACT WITH POWER LINES CAN RESULT

More information

Telegärtner Mobile Radio Base Station Components.

Telegärtner Mobile Radio Base Station Components. Telegärtner Mobile Radio Base Station Components www.telegaertner.com Mobile Radio Base Station Components Components: Connectors EMP Protectors Jumper Cables Adaptors Tools and Accessories 2011 Telegärtner

More information

EVALUATION OF THE EARTH RESISTANCE VALUE FOR ESE LIGHTNING ARRESTOR TECHNIQUE FOR THE SOLAR PLANTS IN INDIA

EVALUATION OF THE EARTH RESISTANCE VALUE FOR ESE LIGHTNING ARRESTOR TECHNIQUE FOR THE SOLAR PLANTS IN INDIA EVALUATION OF THE EARTH RESISTANCE VALUE FOR ESE LIGHTNING ARRESTOR TECHNIQUE FOR THE SOLAR PLANTS IN INDIA Rajat Verma Project Engineer BHEL EDN, BANGALURU, MYSORE ROAD, KARNATAKA 560024, India ABSTRACT

More information

Data sheet. Connection line M12 plug straight - M12 jack straight drag chain suitable, 8-pole, X-coded 2.0 m. Illustrations

Data sheet. Connection line M12 plug straight - M12 jack straight drag chain suitable, 8-pole, X-coded 2.0 m. Illustrations Page 1/7 Illustrations Dimensional drawing Cut-out See enlarged drawings at the end of document Product specification shielded M12 Ethernet connection cable drag chain suitable Cat.6A, 8 pole, X-coded

More information

Safety earthing. Sector Energy PTI NC. Copyright Siemens AG All rights reserved. Theodor Connor

Safety earthing. Sector Energy PTI NC. Copyright Siemens AG All rights reserved. Theodor Connor Safety earthing Sector Energy PTI NC Theodor Connor Copyright Siemens AG 2008. All rights reserved. Content Introduction Theoretical background Soil Analysis Design of earthing system Measurements on earthing

More information

Aluminum HF Vertical Travel Antenna

Aluminum HF Vertical Travel Antenna by Phil Salas AD5X Edited and revised by N.T. Len Carlson, K4IWL INTRODUCTION I ve had a tremendous response to the portable antenna project published in the July 2002 QST. Since this antenna has been

More information

PATRIOT DOCKS ASSEMBLY INSTRUCTIONS

PATRIOT DOCKS ASSEMBLY INSTRUCTIONS 6/1/2008 PATRIOT DOCKS ASSEMBLY INSTRUCTIONS Congratulations on your new Patriot Dock purchase. This manual contains instructions to assemble basic dock configurations for use at typical shoreline application.

More information