SAW CUTS IN PLASTERBOARD CIRCULAR CUTOUT IN PLASTERBOARD CIRCULAR CUTOUT IN PLASTERBOARD SHOWN DOTTED CEILING CUT OUT PATTERN REFLECTOR OPAL DIFFUSER

Size: px
Start display at page:

Download "SAW CUTS IN PLASTERBOARD CIRCULAR CUTOUT IN PLASTERBOARD CIRCULAR CUTOUT IN PLASTERBOARD SHOWN DOTTED CEILING CUT OUT PATTERN REFLECTOR OPAL DIFFUSER"

Transcription

1

2

3 DATA SHEET PHOENIX 350 compact fluorescent SAW CUTS PAINTING GUIDE R177 To achieve the best results we recommend that the products be spray painted to match the adjoining ceiling colour SHOWN DOTTED REFLECTOR OPAL DIFFUSER CEILING CUT OUT PATTERN 354 If spraying is not possible, the products should be painted with a small foam roller, using thin regular paint rather than thick cutting-in paint. Hand sanding between coats is essential. Light incident on the curved surface will emphasize brushmarks so it is important that the finish be absolutely smooth. 350 PHOENIX is a recessed downlight specifically designed to be flush joined with plasterboard ceiling linings. IMPORTANT For use with 10mm or 13mm plasterboard. The plasterboard thickness must be specified at the time of ordering as the fixing flange is not adjustable. FIXING GUIDE The PHOENIX range of Morphers may be installed to steel or timber framed ceilings. No extra framing is required. Sheet the entire ceiling before cutting a circular opening 2mm larger than the protruding rim of the Morpher. Cut two slots diametrically opposite each other to allow the fixing flange to be slipped through and the whole unit to be pushed through to the ceiling void. Position the Morpher into the opening and screw fix through the surrounding plasterboard and metal flange at maximum 75mm centres with self-tapping plasterboard screws. E L E C T R I C A L PX218M VS Magnetic 2 x 18W non dimmable ballast PX218E VS Electronic 2 x 18W PX2M VS Magnetic 2 x W PX2E VS Electronic 2 x W *during installation, pull electrical cable through the opening in the PHOENIX 350. Pack the joint with cornice cement. Finish with top coat. Paint to match surrounding ceiling, hand - sanding between coats to achieve a perfectly seamless appearance. After painting, the control gear and lampholder are to be fitted by a licensed electrician. Morphlight Pty Ltd reserves the right to alter these products, recommendations and specifications without notice. Copyright Morphlight Pty Ltd, 2004

4 DATA SHEET PHOENIX 350 metal halide / lineal halogen SAW CUTS PAINTING GUIDE SHOWN DOTTED R To achieve the best results we recommend that the products be spray painted to match the adjoining ceiling colour. If spraying is not possible, the products should be painted with a small foam roller, using thin regular paint rather than thick cutting-in paint. Hand sanding between coats is essential. 1 REFLECTOR DIFFUSER CEILING CUT OUT PATTERN Light incident on the curved surface will emphasize brushmarks so it is important that the finish be absolutely smooth PHOENIX is a recessed downlight specifically designed to be flush joined with plasterboard ceiling linings. IMPORTANT For use with 10mm or 13mm plasterboard. The plasterboard thickness must be specified at the time of ordering as the fixing flange is not adjustable. FIXING GUIDE The PHOENIX range of Morphers may be installed to steel or timber framed ceilings. No extra framing is required. Sheet the entire ceiling before cutting a circular opening 2mm larger than the protruding rim of the Morpher. Cut two slots diametrically opposite each other to allow the fixing flange to be slipped through and the whole unit to be pushed through to the ceiling void. Position the Morpher into the opening and screw fix through the surrounding plasterboard and metal flange at maximum 75mm centres with self-tapping plasterboard screws. *during installation, pull electrical cable through the opening in the PHOENIX 350. E L E C T R I C A L PX70MH VS 70W transformer & metal halide lamp PX150MH VS 150W transformer & metal halide lamp PX100 LH 100W fitting & lineal halogen lamp PX200LH 200W fitting & lineal halogen lamp Pack the joint with cornice cement. Finish with top coat. Paint to match surrounding ceiling, hand - sanding between coats to achieve a perfectly seamless appearance. After painting, the control gear and lampholder are to be fitted by a licensed electrician. Morphlight Pty Ltd reserves the right to alter these products, recommendations and specifications without notice. Copyright Morphlight Pty Ltd, 2004

5 DATA SHEET PHOENIX 165R low voltage SAW CUTS PAINTING GUIDE To achieve the best results we recommend that the products be spray painted to match the adjoining ceiling colour. R If spraying is not possible, the products should be painted with a small foam roller, using thin regular paint rather than thick cutting-in paint. SHOWN DOTTED CEILING CUT OUT PATTERN Hand sanding between coats is essential. Light incident on the curved surface will emphasize brushmarks so it is important that the finish be absolutely smooth. 167 PHOENIX is a recessed downlight specifically designed to be flush-joined with plasterboard ceiling linings. IMPORTANT For use with 10mm or 13mm plasterboard. The plasterboard thickness must be specified at the time of ordering as the fixing flange is not adjustable. FIXING GUIDE The PHOENIX range of Morphers may be installed to steel or timber framed ceilings. No extra framing is required. Sheet the entire ceiling before cutting a circular opening 2mm larger than the protruding rim of the Morpher. Cut two slots diametrically opposite each other to allow the fixing flange to be slipped through and the whole unit to be pushed through to the ceiling void. Position the Morpher into the opening and screw fix through the surrounding plasterboard and metal flange at maximum 75mm centres with self-tapping plasterboard screws. *during installation, pull electrical cable through the opening in the PHOENIX 165. E L E C T R I C A L PX12V M PX12V E 50W magnetic ATCO LVL series transformer and lamp 60W electronic ATCO possum transformer and lamp Pack the joint with cornice cement. Finish with top coat. Paint to match surrounding ceiling, hand - sanding between coats to achieve a perfectly seamless appearance. After painting, the control gear and lampholder are to be fitted by a licensed electrician. Morphlight Pty Ltd reserves the right to alter these products, recommendations and specifications without notice. Copyright Morphlight Pty Ltd, 2004

6 INSTALLATION GUIDE PHOENIX SAW CUTS 1 FORM OPENING R84 2 PASS MORPHER THROUGH OPENING TO VOID BEYOND 3 POSTION MORPHER IN OPENING AND SCREW-FIX THROUGH CEILING LINING Morphlight Pty Ltd reserves the right to alter these products, recommendations and specifications without notice. Copyright: Morphlight Pty Ltd, 2004

Bionic 4 PERIMETER, CONTINUOUS RUN X3, X7

Bionic 4 PERIMETER, CONTINUOUS RUN X3, X7 I NSTALLAT ION INSTRUC TIONS 6 3 /4 6 3 /4 3¾ 5 1 /2 For LP installs, ceiling opening is equal to row length + 3 /4 8 1 /2 4 3 /32 5 1 /4 Flush X7 Shown PARTS SHIPPED SEPARATELY 4 3 /32 5 1 /4 3" Regressed

More information

LASTS UP TO 2X LONGER THAN OTHER LED BULBS CONSUMES LESS ELECTRICITY VS. CFL BULBS UP TO 50% BRIGHTER VS. CFL BULBS.

LASTS UP TO 2X LONGER THAN OTHER LED BULBS CONSUMES LESS ELECTRICITY VS. CFL BULBS UP TO 50% BRIGHTER VS. CFL BULBS. LASTS UP TO 2X LONGER THAN OTHER LED BULBS CONSUMES LESS ELECTRICITY VS. CFL BULBS UP TO 50% BRIGHTER VS. CFL BULBS Contact Person: FIREFLY ELECTRIC & LIGHTING CORP. 7/F Zen Offices Bldg. 1111 Natividad

More information

RAIL 4 INSTALLATION INSTRUCTIONS. RM4DOD Recessed GENERAL SAFETY INSTRUCTIONS: NOTE:

RAIL 4 INSTALLATION INSTRUCTIONS. RM4DOD Recessed GENERAL SAFETY INSTRUCTIONS: NOTE: INSTALLATION INSTRUCTIONS RAIL 4 RM4DOD Recessed NOTE: The following instructions provide general guidelines for product installation. For additional information consult the applicable electrical codes

More information

INSTALLATION GUIDE. 1. Overview. 2. Measuring. 3. Tools & fixings you will need B C. Opening Width. Opening Height

INSTALLATION GUIDE. 1. Overview. 2. Measuring. 3. Tools & fixings you will need B C. Opening Width. Opening Height INSTALLATION GUIDE Please take a few minutes to read through this guide before getting started. 1. Overview A Typical Sliding Wardrobe Door Layout A Frame - Top Liner (optional) B Top Track C Frame - Strike

More information

Inde-Pendants Family. 32L Ring Plaster Trim, Grid and Drywall Ceiling Types. Document No Installation instructions for 32L-Rxx-P

Inde-Pendants Family. 32L Ring Plaster Trim, Grid and Drywall Ceiling Types. Document No Installation instructions for 32L-Rxx-P Inde-Pendants Family 32L Ring Plaster Trim, Grid and Drywall Ceiling Types Installation instructions for 32L-Rxx-P Document No. Supplied by Litecontrol 32L Inde-Pendants: Ring (Plaster Trim, Grid and Drywall

More information

Trim type: Shadow gap. Fire rating: FD30. Enigma. Pocket sliding door systems. Installation instructions FD30 S

Trim type: Shadow gap. Fire rating: FD30. Enigma. Pocket sliding door systems. Installation instructions FD30 S Trim type: Shadow gap Fire rating: FD0 Enigma Pocket sliding door systems 1 2 FD0 S Installation instructions Thank you for choosing Enigma To ensure the installation process is simple and efficient we

More information

Build the Spitfire: Step-By-step. Pack 7 Stages 61-71

Build the Spitfire: Step-By-step. Pack 7 Stages 61-71 Pack 7 Stages 61-71 1 Stage Contents Page Number 61 212-215 62 216-218 63 219-221 64 222-224 65 225-228 66 229-231 67 232-235 68 236-238 69 239-241 70 242-245 71 246-249 Editorial and design by Continuo

More information

Installing Faux Beams by Sennell

Installing Faux Beams by Sennell Installing Faux Beams by Sennell Tools and hardware required Fret saw (ideal), Stanley knife or similar sharp serrated edge knife Sanding block with 180 medium sandpaper Piece of cornice, if fitting beam

More information

Inde-Pendants Family. 32L Surface Mount Cylinder Plaster Trim, Grid and Drywall Ceiling Types. Document No

Inde-Pendants Family. 32L Surface Mount Cylinder Plaster Trim, Grid and Drywall Ceiling Types. Document No Inde-Pendants Family 32L Surface Mount Cylinder Plaster Trim, Grid and Drywall Ceiling Types Installation instructions for 32L-C-S-D Document No. Supplied by Litecontrol 32L Inde-Pendants: Cylinder (Surface

More information

SELECTION

SELECTION SELECTON 2018 1 GENERAL CARACTERSTCS passive heat sink high luminous efficiency, low power consumption high colour rendering index (CR>80) available in 3000K and 4000K considerate to environment without

More information

Smooth Operators. CS TrackSystems range offers a track system for every surface sliding doorway situation.

Smooth Operators. CS TrackSystems range offers a track system for every surface sliding doorway situation. Smooth Operators CS Systems is a range of high quality tracks. They are based on the one-piece heavy duty aluminium extrusions used in CS Cavity Sliders, and can be used for a multitude of applications.

More information

Horizontal Shaft Wall

Horizontal Shaft Wall SYSTEMS 317 INSTALLATION 319 GENERAL REQUIREMENTS 319 FRAMING 319 PLASTERBOARD LAYOUT 320 PLASTERBOARD FIXING 320 CONSTRUCTION DETAILS 321 Horizontal Shaft Wall Horizontal Shaft Wall is constructed in

More information

force Use the A lounge room makeover that s out of this world! With its iconic scenes Use the OCTOBER 2015

force Use the A lounge room makeover that s out of this world! With its iconic scenes Use the OCTOBER 2015 OCTOBER 2015 SEEN ON BHG TV BEFORE force A lounge room makeover that s out of this world! With its iconic scenes of galactic fantasy, Star Wars is one of cinema s most popular film series. Now you can

More information

Lightplane 3.5 Recessed

Lightplane 3.5 Recessed INSTALLATION INSTRUCTIONS Lightplane 3.5 Recessed LP3.5R Recessed Ceiling IMPORTANT SAFETY INSTRUCTIONS When installing or using this fixtures basic safety precautions must be followed. Read all instructions

More information

GYPROC. Cove and Cornice Decorative room features....made easy

GYPROC. Cove and Cornice Decorative room features....made easy GYPROC Cove and Cornice Decorative room features...made easy 1 2 3 4 1 2 3 4 Gyproc Cove with one Cornice Strip on ceiling and wall. Gyproc Cove with two Cornice Strips on ceiling and wall. Gyproc Cornice

More information

General Installation Instructions LED

General Installation Instructions LED General Installation Instructions LED To reduce the risk of death, personal injury or property damage from fire, electric shock, falling parts, cuts/abrasions and other hazards, please read all warnings

More information

It is important to use the right ballast to ensure the luminaire also ignites at low temperatures.

It is important to use the right ballast to ensure the luminaire also ignites at low temperatures. LINGO n. pl. ling goh. (Informal) The specialized vocabulary of a particular field or discipline. The language and speech, esp. the jargon, slang, or argot, of a particular field, group, or individual:

More information

Holemaking Products & Accessories

Holemaking Products & Accessories Holemaking Products & Holemaking Products & Made of top-of-the-line materials for longer lasting performance, Klein's diverse line of drill bits and holemaking products and accessories provide accuracy

More information

RECESSED ASYMMETRIC MOUNT

RECESSED ASYMMETRIC MOUNT PROJECT INFORMATION Project: Notes: Type: DIMENSIONS SECTION VIEWS 4 5/32 IC culus Listed Type I.C. ORDERING CODE 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 PRODUCT SPECIFICATIONS 1 PRODUCT ID 2 OPTICS DIRECT

More information

4 Position the Suntile to the x tile s position and mark the felt around the square box flange. Then remove the Suntile

4 Position the Suntile to the x tile s position and mark the felt around the square box flange. Then remove the Suntile 4 Position the Suntile to the x tile s position and mark the felt around the square box flange. Then remove the Suntile 5 Using a sharp bladed knife, cut through the felt from corner to corner in an x

More information

Sauna & Steam. Traditional Sauna Installation Instruction Manual

Sauna & Steam. Traditional Sauna Installation Instruction Manual Traditional Sauna Installation Instruction Manual Oceanic Ltd, Pountney Street, Wolverhampton, WV2 4HX Phone: 01902 450 550 sales@oceanic-saunas.co.uk www.oceanic-saunas.co.uk Contents 1.Introduction................................................

More information

and office FLUORESCENT AND OFFICE T4 - T5 Linkable Ceiling mount Mirror Trimless Industrial Wall and suspended

and office FLUORESCENT AND OFFICE T4 - T5 Linkable Ceiling mount Mirror Trimless Industrial Wall and suspended fluorescent and office FLUORESCENT AND OFFICE T4 - T5 Linkable Ceiling mount Mirror Trimless Industrial Wall and suspended 70 7 FLUORESCENT T4 Linkable FLUORESCENT T5 Linkable 3835B 2V T5 35W IP20 Plastic

More information

FOCAL ADVANTAGES DESCRIPTION CHARACTERISTICS

FOCAL ADVANTAGES DESCRIPTION CHARACTERISTICS ADVANTAGES Compact floodlight Wide choice of reflectors, lamps and accessories Adjustable beam while switched on Tightness: IP 66 DESCRIPTION Floodlight (IP 66) for lamps up to 150 W, consisting of a painted,

More information

VoglFuge. Continuously perforated plasterboard acoustic ceiling

VoglFuge. Continuously perforated plasterboard acoustic ceiling VoglFuge Continuously perforated plasterboard acoustic ceiling Designer Ceilings Without Filler Designed and manufactured in Germany, VoglFuge by Atkar Group is the leader in the acoustic plasterboard

More information

PRO CYC PRO CYC, INC. SYSTEM SUPER 3EZ

PRO CYC PRO CYC, INC. SYSTEM SUPER 3EZ ASSEMBLY INSTRUCTIONS SYSTEM SUPER 3 EZ Congratulations on your decision to use the world s most advanced and user-friendly cyclorama system. We have taken a great deal of care to create and ship your

More information

Brick, blockwork and concrete walls are also suitable providing the surfaces are flush without excessively wide mortar joints.

Brick, blockwork and concrete walls are also suitable providing the surfaces are flush without excessively wide mortar joints. Data Sheet: (sheet 1 of 8) August 2016 1. Substrate suitability and recommended preparation All material must be installed in environmentally controlled conditions. Allow the SureProtect Pure PVC-u sheet

More information

Salter Industries Spiral Stair

Salter Industries Spiral Stair Salter Industries Spiral Stair The Leader in Spiral Staircases Continuous Sleeve Stair Installation Instructions TOOLS NEEDED: 1. Electric drill with hex chuck and Phillips bit 2. Drill bits 1/8", 1/4",

More information

3-1/4 LED RECESSED ADJUSTABLE AND DOWNLIGHT 800/1200 LUMEN ROUND APERTURE REMODEL IC408LR, TC412LR

3-1/4 LED RECESSED ADJUSTABLE AND DOWNLIGHT 800/1200 LUMEN ROUND APERTURE REMODEL IC408LR, TC412LR PRODUCT DESCRIPTION Recessed adjustable LED remodel luminaire produces up to 00 delivered lumens. Fixture has 50 visual cutoff. Low profile housing is available in both IC and Non-IC rated configurations.

More information

GENERAL PURPOSE RECESSED DOWNLIGHT ACCESSORIES

GENERAL PURPOSE RECESSED DOWNLIGHT ACCESSORIES 2 GENERAL PURPOSE RECESSED DOWNLIGHT ACCESSORIES 1 13 GENERAL PURPOSE RECESSED DOWNLIGHT ACCESSORIES 4 1 2-PIN CFL 2 4-PIN CFL 3 MR16 LAMP 4 MR16 FILTERS APPLICATIONS RESIDENTIAL AND ARCHITECTURAL APPLICATIONS

More information

2. Sanding the Modules Sand the entire surface of each cyc module with 60-grit sandpaper. This will provide for better paint adhesion.

2. Sanding the Modules Sand the entire surface of each cyc module with 60-grit sandpaper. This will provide for better paint adhesion. ASSEMBLY INSTRUCTIONS SYSTEM SUPER 2.5 EZ Congratulations on your decision to use the world s most advanced and user-friendly cyclorama system. We have taken a great deal of care to create and ship your

More information

Cove and Cornice Decorative room features

Cove and Cornice Decorative room features GYPROC Cove and Cornice Decorative room features 1 2 3 4 1 2 3 4 Gyproc Cove with one Cornice Strip on ceiling and wall. Gyproc Cove with twocornice Strips on ceiling and wall. Gyproc Cove with one Cornice

More information

Più piano»cc«datasheet

Più piano»cc«datasheet Datasheet LED recessed spotlight for hollow ceilings or solid ceilings with ceiling box. Mounting flush with ceiling (Più piano) and recessed installation (Più piano in) are both possible. Optionally available

More information

SLOT INSTALLATION GUIDE Indoor IP20

SLOT INSTALLATION GUIDE Indoor IP20 Please read entire guide prior to starting installation. Sections: Pre-Installation Single Run Fed From Both Ends NOTES 1. IP40 and lower tape must be installed indoors only. Installing outdoors will void

More information

COMPACT. Assembly Instructions

COMPACT. Assembly Instructions UK COMPACT Assembly Instructions 1 Dear Friend: Thank you for purchasing the new Compact ComposTumbler. Properly assembled and operated, your new tumbler can go on giving you rich, healthy compost for

More information

Australian Vintage Radio Society Inc.

Australian Vintage Radio Society Inc. Australian Vintage Radio Society Inc. (Incorporated in Victoria A0050003S) P.O. Box 3099, Syndal L.P.O., Victoria, 3150, Australia. Cabinet assembly instructions for the AVRS 10 th Anniversary construction

More information

Build your own. Stages 7-10: See Robi s head move for the first time

Build your own. Stages 7-10: See Robi s head move for the first time Build your own Pack 03 Stages 7-10: See Robi s head move for the first time Build your own All rights reserved 2015 Published in the UK by De Agostini UK Ltd, Battersea Studios 2, 82 Silverthorne Road,

More information

SPEEDFRAME T h e s p e e d y w a y t o b e i n d i v i d u a l

SPEEDFRAME T h e s p e e d y w a y t o b e i n d i v i d u a l SPEEDFRAME T h e s p e e d y w a y t o b e i n d i v i d u a l T h e a l l p u r p o s e c o n s t r u c t i o n k i t SPEEDFRAME All materials are kept close to hand in this specially designed Speedframe

More information

PRO CYC PRO CYC, INC. SYSTEM SUPER 1.5 EZ

PRO CYC PRO CYC, INC. SYSTEM SUPER 1.5 EZ ASSEMBLY INSTRUCTIONS SYSTEM SUPER 1.5 EZ Congratulations on your decision to use the world s most advanced and user-friendly cyclorama system. We have taken a great deal of care to create and ship your

More information

How to repair a wall or ceiling FREE

How to repair a wall or ceiling FREE How to repair a wall or ceiling FREE How to repair a wall or ceiling This guide shows how to repair walls and ceilings throughout the guide we only refer to walls but the same principles apply to ceiling

More information

Inde-Pendants Family. 32L Surface Mount Cylinder with Ring Plaster Trim, Grid and Drywall Ceiling Types. Document No

Inde-Pendants Family. 32L Surface Mount Cylinder with Ring Plaster Trim, Grid and Drywall Ceiling Types. Document No Inde-Pendants Family 32L Surface Mount Cylinder with Ring Plaster Trim, Grid and Drywall Ceiling Types Installation instructions for 32L-CRxx-S-D Document No. Supplied by Litecontrol 32L Inde-Pendants:

More information

Correct cap type? e.g. Bayonet Edison Screw GU 10 MR 16. Suitable colour temperature? Warm (3000 K) Cool (4000 K) Bright White (5000+ K)

Correct cap type? e.g. Bayonet Edison Screw GU 10 MR 16. Suitable colour temperature? Warm (3000 K) Cool (4000 K) Bright White (5000+ K) LED BUYER S GUIDE Save energy, time and money with the right LED purchase LED technology has rapidly evolved in the past seven years and is now quickly gaining popularity in the household, representing

More information

Finishing Plasterboard

Finishing Plasterboard Finishing Plasterboard 4.1 Levels of Finish 346 Australian Standard Requirements 346 Level 3 Finish 347 Level 4 Finish 347 Level 5 Finish 347 4.2 Back-Blocking 348 Back-Blocking Requirements 349 Back-Blocking

More information

Au. di VoglFuge data sheet

Au. di VoglFuge data sheet Head Office 17 19 David Lee Road Hallam Victoria 3803 PO Box 1143 Narre Warren MDC 3805 T 03 9796 3333 WA/SA Region PO Box 710 Joondalup DC 6919 T 08 6323 5662 atkar.com.au TM Au. di VoglFuge data sheet

More information

THE WETROOM SPECIALIST. EasyFit Dec Installation Guide

THE WETROOM SPECIALIST. EasyFit Dec Installation Guide EasyFit Dec Installation Guide Issue 3 09/06/2014 EasyFit Dec Installation Guide SAFETY Please read these installation instructions carefully before proceeding. Keep guide for future reference. If you

More information

Standard drawer runner program

Standard drawer runner program Standard drawer runner program i 230M Single extension, Blumatic self-closing drawer runners s: 250mm (10") to 650mm (26") 230 series drawer runners Cabinet profile Drawer profile Rear mount sockets available

More information

PEMBRIDGE PICNIC TABLE INSTRUCTIONS MANUAL

PEMBRIDGE PICNIC TABLE INSTRUCTIONS MANUAL PEMBRIDGE PICNIC TABLE INSTRUCTIONS MANUAL IMPORTANT NOTE: ENSURE THAT ALL RELEVANT PERSONNEL READ THESE INSTRUCTIONS PRIOR TO USE Please also refer to the Manual Handling Operations Regulations 1992 during

More information

for Rigid Sun Lite Planning the layout

for Rigid Sun Lite Planning the layout for Rigid Sun Lite These instructions refer to installations on a flat and pitched roof. Various roof flashing units are available according to the particular roof covering. The roof flashing will be boxed

More information

TIE-ROD AND PIPE JOINTS

TIE-ROD AND PIPE JOINTS CHAPTER 5 Machines use various parts which are joined in several ways for the machine to function as whole. We have learnt about some devices like fasteners (temporary & permanent) and some simple joints

More information

Inclusions Brochure Stages 3 and 4

Inclusions Brochure Stages 3 and 4 Modern Exteriors Stylish Kitchens Designer Bathrooms Fixtures & Finishes Schedule Inclusions Brochure Stages 3 and 4 W EL L A PP O IN T ED Modern Exteriors 1. 4. 3. 2. 6. 5. 7. 9. 8. House Design Capri.

More information

INSTALLATION RECOMMENDATIONS For The Con-Tech ODYSSEY Line Voltage Flexible Track System

INSTALLATION RECOMMENDATIONS For The Con-Tech ODYSSEY Line Voltage Flexible Track System INSTALLATION RECOMMENDATIONS For The Con-Tech ODYSSEY Line Voltage Flexible Track System IMPORTANT SAFETY INSTRUCTIONS: Read all instructions before installation. Save these instructions for later use.

More information

BUILD YOUR OWN. Pack 12

BUILD YOUR OWN. Pack 12 BUILD YOUR OWN TM Pack 12 177 CONTENTS Assembly Guide 179 Stage 38: The right crankcase half Stage 39: The IR sensor board Stage 40: The left crankcase half Editorial and design by Continuo Creative, 39-41

More information

Installation Instructions For Aurora Dual MR16 Round & Square Edge 3.3" Fig.1 Complete Fixture ADJUSTABLE GEARS HIDDEN BEHIND THE LAMP PAN LOCK

Installation Instructions For Aurora Dual MR16 Round & Square Edge 3.3 Fig.1 Complete Fixture ADJUSTABLE GEARS HIDDEN BEHIND THE LAMP PAN LOCK 2015 Pure Lighting. All Rights Reserved. Installation Instructions For Aurora Dual MR16 Round & Square Edge 3.3" 1718 W. Fullerton Ave Chicago, IL 60614 Tel: 773-770-1195 Fax: 773-935-5613 www.purelighting.com

More information

Patrol Box Plans by David J. Yarusso Troop 609

Patrol Box Plans by David J. Yarusso Troop 609 Patrol Box Plans by David J. Yarusso Troop 609 Materials List: 1. One 4 x8 sheet of ½ thick cabinet grade (birch or oak) or AC plywood. If using AC grade, use the A grade surface on the outside for a clean

More information

INSPIRATION: SHOOTING STAR CARBON DIAMOND

INSPIRATION: SHOOTING STAR CARBON DIAMOND RANGE INSPIRATION: SHOOTING STAR CARBON DIAMOND The Indelague Group follows a bold and contemporary product design aesthetic. Winner of the German Design Award 2017, with a Special Mention - Excellent

More information

Line volt rail & fixtures. Low volt quick connect fixtures with transformers

Line volt rail & fixtures. Low volt quick connect fixtures with transformers INSTRUCTIONS: Line Volt Flexrail2 Safety Instructions: A qualified electrician must install system only. System is intended for installation in accordance with National Electric Code, local and Federal

More information

Super 2.5-EZ. Sheetrock Wall. Sheetrock Wall 10'-10" 2.5V-EZ 2.5V-EZ 2.5A-EZ

Super 2.5-EZ. Sheetrock Wall. Sheetrock Wall 10'-10 2.5V-EZ 2.5V-EZ 2.5A-EZ Super 2.5-EZ Company: 30 Vertical Radius Phone: 36 Horizontal Radius w/12 Wide Flat Expansion in Corner Non-Parabolic Corner Easy Installation Built-In System Date: 24'-1/2" 20'-1/2" 16'-1/2" 12'-1/2"

More information

2. Sanding the Modules Sand the entire surface of each cyc module with 60-grit sandpaper. This will provide for better paint adhesion.

2. Sanding the Modules Sand the entire surface of each cyc module with 60-grit sandpaper. This will provide for better paint adhesion. ASSEMBLY INSTRUCTIONS SYSTEM 4 BI (Built-In) Congratulations on your decision to use the world s most advanced and user-friendly cyclorama system. We have taken a great deal of care to create and ship

More information

ASS 70 FD folding/sliding door installation guide

ASS 70 FD folding/sliding door installation guide ASS 70 FD folding/sliding door installation guide 2 Preparation IMPORTANT These doors should be fitted by competent and trained installers. Please read these instructions thoroughly before beginning the

More information

LED RECESSED ADJUSTABLE 3-1/4 APERTURE Non-IC Rated, 1000 LUMEN TC49L, TC949L

LED RECESSED ADJUSTABLE 3-1/4 APERTURE Non-IC Rated, 1000 LUMEN TC49L, TC949L PRODUCT DESCRIPTION Recessed adjustable 0W LED luminaire produces up to 000 fixture lumens (depending on trim) and approximates the performance of a 75W MR6 lamp. Fixture has 50 visual cutoff and features

More information

- 2 JOINER ALIGNERS - 2 JOINING BRACKETS - 4 HEX BOLTS. Factory pre-installed mud flange TOOLS REQUIRED: Phillips screwdriver, 5/16 nut driver.

- 2 JOINER ALIGNERS - 2 JOINING BRACKETS - 4 HEX BOLTS. Factory pre-installed mud flange TOOLS REQUIRED: Phillips screwdriver, 5/16 nut driver. - 2 JOINER ALIGNERS - 2 JOINING BRACKETS - 4 HEX BOLTS TruGroove Drywall A3 MOUNTING Ceiling INSTALLATION System Overview These instructions review how to install drywall trim versions of TruGroove recessed

More information

Sharp LED Lighting. Introduction. April 2015

Sharp LED Lighting. Introduction. April 2015 Sharp LED Lighting Introduction April 2015 /This is Why: Sharp benefits 100 years of product innovation 45 years of LED technology Quality products 3-5 year warranty Lighting design support (specification

More information

Gyproc Proflex Access Panels - Installation Guidance Notes

Gyproc Proflex Access Panels - Installation Guidance Notes Gyproc Proflex ccess Panels - Installation Guidance Notes The following notes are intended as guidance only, depicting the basic sequence of installation. In practice, consideration should be given to

More information

DOWNLIGHT LED SERIES INSTALLATION INSTRUCTIONS

DOWNLIGHT LED SERIES INSTALLATION INSTRUCTIONS WARNING: This product must be installed in accordance with the applicable installation code by a person familiar with the construction and operation of the product and the hazards involved. Make sure all

More information

Decorating Prep

Decorating Prep Decorating Prep 13-02-2017 Physical Works Completed as of 07-02-17 - Joinery Master Bedroom 1. Wardrobe installed by joiner with MDF frame flush with wall with pockets and electrical and lighting feeds

More information

FOTO CLAM SELECTION 2006

FOTO CLAM SELECTION 2006 FOTO SELECTION 2006 Design Thomas Bernstrand & Mattias Ståhlbom. Floor lamp with adjustable spotlight. Swivelling and telescopic steam. Die-casted aluminium, finished white. HF ballast as standard. Also

More information

Rondo exangle. Drywall Finishing Sections. for interior applications only revised: april 2008

Rondo exangle. Drywall Finishing Sections. for interior applications only revised: april 2008 Rondo exangle Drywall Finishing Sections for interior applications only revised: april 2008 design considerations general information The Rondo exangle range of finishing sections for building board applications

More information

pholstered Vanity Seat

pholstered Vanity Seat U pholstered Vanity Seat For years I sat on an extremely uncomfortable chair to apply my makeup. I finally replaced it with this sturdy seat that is both attractive and comfortable. This finished size

More information

Side Light Frame Pack Assembly Instructions

Side Light Frame Pack Assembly Instructions Please read this complete set of assembly instructions before starting the installation and only when you understand the construction method start to follow the step by step guide. IDENTIFY THE PACK CONTENTS

More information

Linda Barker Collection Heritage Collection Classic Collection INSTALLATION GUIDE

Linda Barker Collection Heritage Collection Classic Collection INSTALLATION GUIDE Linda Barker Collection Heritage Collection Classic Collection INSTALLATION GUIDE Ruler Pencil Masking tape Measuring tape Silicone sealant & silicone gun Power drill & screwdriver High-grab adhesive Jig

More information

Shaft Wall SYSTEMS 210 INSTALLATION 211. Shaft Wall systems are fire rated non-load bearing walls used for shafts and service ducts.

Shaft Wall SYSTEMS 210 INSTALLATION 211. Shaft Wall systems are fire rated non-load bearing walls used for shafts and service ducts. SYSTEMS 210 INSTALLATION 211 GENERAL REQUIREMENTS 211 FRAMING 212 PLASTERBOARD LAYOUT 213 PLASTERBOARD FIXING 214 CONSTRUCTION DETAILS 217 Shaft Wall Shaft Wall systems are fire rated non-load bearing

More information

rondo exangle drywall finishing sections

rondo exangle drywall finishing sections rondo exangle drywall finishing sections SUMMARY The EXANGLE range of building board finishing profiles are designed to give plasterers a clean, defined edge on straight or curved details for internal

More information

ELiTE ProPanel Installation Guide

ELiTE ProPanel Installation Guide ELiTE ProPanel Installation Guide ELiTE ProPanel Installation Guide Impaling Clips Figure 1.1 Impaling Clip installation side view Figure 1.2 Impaling Clip placement on 4 x8 panel Figure 1.3 Impaling Clip

More information

INSTALLATION INSTRUCTIONS FOR FLUSH MOUNT FIXTURES

INSTALLATION INSTRUCTIONS FOR FLUSH MOUNT FIXTURES Kurt Versen Company Point Source Lighting 10 Charles Street Westwood, New Jersey Models with Square or Rectangular Apertures 1 PLEASE READ THIS ENTIRE INSTRUCTION SHEET BEFORE INSTALLATION. 2 DISCONNECT

More information

D T D O W N L I G H T S

D T D O W N L I G H T S D T D O W N L I G H T S The DOT Downlight Range was introduced in 198. Since its launch, it has evolved primarily in response to suggestions and feedback from building owners, electrical contractors,

More information

Side Light Frame Pack Assembly Instructions

Side Light Frame Pack Assembly Instructions Side Light Frame Pack Assembly Instructions Please read this complete set of assembly instructions before starting the installation and only when you understand the construction method start to follow

More information

FOGLIO. Technical Features SURFACE, PENDANT & RECESSED LUMINAIRES

FOGLIO. Technical Features SURFACE, PENDANT & RECESSED LUMINAIRES SURFACE, PENDANT & RECESSED LUMINAIRES RECESSED FOGLIO The FOGLIO recessed-mounted luminaire with its opal cover provides perfect lighting comfort and glare-free lighting. The luminaire unit impresses

More information

Column and Beam Fire Protection SYSTEMS 335 INSTALLATION 337 GENERAL REQUIREMENTS 337 FRAMING 337

Column and Beam Fire Protection SYSTEMS 335 INSTALLATION 337 GENERAL REQUIREMENTS 337 FRAMING 337 SYSTEMS 335 INSTALLATION 337 GENERAL REQUIREMENTS 337 FRAMING 337 PLASTERBOARD LAYOUT 337 PLASTERBOARD FIXING 337 CONSTRUCTION DETAILS 341 Column and Beam Fire Protection Column and beam protection systems

More information

CATALOGUE OF WALL LIGHTS 2012

CATALOGUE OF WALL LIGHTS 2012 CATALOGUE OF WALL LIGHTS 2012 Tel: 028 313 2495/084 260 0475 Fax: 086 664 0406 info@divali.co.za WALL LIGHTS WITH TEXTURED FINISH - EXCLUDES LAMPHOLDERS (see prices below) WAHIBA plain M-1A-N 1 x 14w WAHIBA

More information

Lamp type 17 17W T8 (24") 14T5 14W T5 (22") 24T5HO 24W T5 (22") CF40 40W TT5 (24") CF50 50W TT5 (24")

Lamp type 17 17W T8 (24) 14T5 14W T5 (22) 24T5HO 24W T5 (22) CF40 40W TT5 (24) CF50 50W TT5 (24) Recessed Direct/Indirect Lighting Avante 2' X 2' 2 x 2 Symmetric,MDR Intended Use Originally developed for the small private office, Avante 2x2 fixtures also are effective in corridors, libraries and food-service

More information

Trestle Table and Benches Materials List

Trestle Table and Benches Materials List Project 18444EZ: Trestle Table and Benches In the early days of our country, trestle tables were popular because they could easily be disassembled and moved out of the way when not in use no small advantage

More information

Installation Instructions For Aurora Halogen Accent Housing 3 Round & Square Trimless AH1-ARE, AH1-ARB, AH1-ASE, AH1-ASB. Fig.

Installation Instructions For Aurora Halogen Accent Housing 3 Round & Square Trimless AH1-ARE, AH1-ARB, AH1-ASE, AH1-ASB. Fig. 2015 Pure Lighting. All Rights Reserved. Installation Instructions For Aurora Halogen Accent Housing 3 Round & Square Trimless AH1-ARE, AH1-ARB, AH1-ASE, AH1-ASB 1718 W. Fullerton Ave Chicago, IL 60614

More information

EXPLODED VIEW AND PART CALL OUT ASSEMBLING THE METALUX DF SERIES FRAME KIT

EXPLODED VIEW AND PART CALL OUT ASSEMBLING THE METALUX DF SERIES FRAME KIT EXPLODED VIEW AND PART CALL OUT CUTOUT DIMENSIONS ON PAGE 2 CEILING BRACING (BY OTHERS) SHEET ROCK METALUX DF SERIES FRAME KIT S282 (2'X2') FIXTURE SHOWN FIXTURE SIZE FRAME KIT PART # 2' X 2' DF-22W-U

More information

Installation Instructions Standalone or continuous run configurations - 2 JOINER ALIGNERS - 2 JOINING BRACKETS - 4 HEX BOLTS

Installation Instructions Standalone or continuous run configurations - 2 JOINER ALIGNERS - 2 JOINING BRACKETS - 4 HEX BOLTS - 2 JOINER ALIGNERS - 2 JOINING BRACKETS - 4 HEX BOLTS TruGroove Drywall A3 MOUNTING Ceiling INSTALLATION System Overview These instructions review how to install trimless drywall versions of TruGroove

More information

Build Instructions for Towers of Doom

Build Instructions for Towers of Doom Build Instructions for Towers of Doom 1. Measure and cut 4 x 8 sheet of plywood in half (or ask Home Depot to do it!). You will use one 4 x 4 sheet for the course base. 2. Attach a support frame to the

More information

Compose your system with the help of the example below. All components can be found on the following pages and need to be ordered separately.

Compose your system with the help of the example below. All components can be found on the following pages and need to be ordered separately. LAYOUT SYSTEM CONFIGURATION EXAMPLE Compose your system with the help of the example below. All components can be found on the following pages and need to be ordered separately. Electrical feed connection

More information

CABLE COVER ORGANIZER KIT USER GUIDE AND INSTALLATION INSTRUCTIONS

CABLE COVER ORGANIZER KIT USER GUIDE AND INSTALLATION INSTRUCTIONS CABLE COVER ORGANIZER KIT USER GUIDE AND INSTALLATION INSTRUCTIONS TOPIC PAGE Applications, Specifications, Warnings and Cautions 2 Kit Contents 3 Installation Instructions Painting. 4 Layout Preparation...

More information

Ray chair & half. assembly instructions

Ray chair & half. assembly instructions Ray chair & half assembly instructions Smooth & Wrinkle-Free Fabric Covers: In addition to these printed instructions, you may want to watch our beauty tips videos on the customer service page of our website.

More information

San Felipe: Step by Step Pack 3

San Felipe: Step by Step Pack 3 Pack 3 Your parts Bulwarks Gun port covers x 2 Tools and equipment Wood glue Sandpaper Brushes Wood stain Hammer Pin pusher/nails Razor saw a Remove the longer bulwark and test-fit it in place at the bow

More information

DUALCASE VERSATILE ALUMINIUM SIGN SYSTEM

DUALCASE VERSATILE ALUMINIUM SIGN SYSTEM VERSATILE ALUMINIUM SIGN SYSTEM Universal Components Ltd. May 2007 Introduction Nothing beats DualCase for speed of fabrication, aesthetic appearance and easy maintenance. With the minium of components

More information

3-1/4 LED RECESSED ADJUSTABLE AND DOWNLIGHT 800/1200/1500/2000 LUMEN SQUARE APERTURE NEW CONSTRUCTION IC/TC420LSQ, IC415LSQ, IC412LSQ, IC408LSQ

3-1/4 LED RECESSED ADJUSTABLE AND DOWNLIGHT 800/1200/1500/2000 LUMEN SQUARE APERTURE NEW CONSTRUCTION IC/TC420LSQ, IC415LSQ, IC412LSQ, IC408LSQ PRODUCT DESCRIPTION Recessed adjustable LED luminaire produces up to 000 delivered lumens. Fixture has 50 visual cutoff and features precision geared hot-aiming. Sealed Air-Loc housing ensures maximum

More information

INPLANAI ONPLANA RADIANCE TO GET EXCITED ABOUT

INPLANAI ONPLANA RADIANCE TO GET EXCITED ABOUT INPLANAI ONPLANA RADIANCE TO GET EXCITED ABOUT INPLANAI ONPLANA A SINGLE DESIGN WITH MANY OPTIONS A glance up at the ceiling says more than a thousand words. It's here that the TRILUX Inplana and Onplana

More information

Garden Bridge. c D E. All dimensions are in mm- Arch Tread Handrail' Post Reinforcement brace. Written & designed by David Watkins.

Garden Bridge. c D E. All dimensions are in mm- Arch Tread Handrail' Post Reinforcement brace. Written & designed by David Watkins. Garden Bridge Written & designed by David Watkins Slmple by design yet decorative by nature. This ornate Garden Bridge will rest proudly amongst most garden backdrops. The fiddliest step in this project

More information

Use timers, motion detectors, remote controls, and photocells to reduce waste.

Use timers, motion detectors, remote controls, and photocells to reduce waste. Exterior Exterior luminaires include large-area flood and small-area, landscape, and accent luminaires. They illuminate building facades, pathways, and landscapes and can provide lighting for safety, security,

More information

E-AERO EPP PITTS KIT From BP HOBBIES. Parts Included in kit

E-AERO EPP PITTS KIT From BP HOBBIES. Parts Included in kit E-AERO EPP PITTS KIT From BP HOBBIES Parts Included in kit Thank you for purchasing the BP Hobbies/E-aero EPP Pitts. Please take the time to read through the instruction manual before beginning the build.

More information

Rockfon System OlympiaPlus A Impact 1A

Rockfon System OlympiaPlus A Impact 1A System description Rockfon System OlympiaPlus A Impact 1A Ceiling systems for special applications Impact resistance SYSTE GRP WAR YEARS IT LIM ED E very single tile is demountable for easy and fast access

More information

This letter is to confirm the results of an indicative fire resistance test undertaken on 25 th November 2010.

This letter is to confirm the results of an indicative fire resistance test undertaken on 25 th November 2010. Chiltern House Stocking Lane Hughenden Valley High Wycombe Buckinghamshire HP14 4ND UK t +44 (0) 1494 569 800 f +44 (0) 1494 564895 e cif@chilternfire.co.uk w www.chilternfire.co.uk Re: Indicative Fire

More information

Dura-Lock Roof System

Dura-Lock Roof System DLR-14 Dura-Lock Roof System Assembly and Installation Instructions Read the instructions before starting the job. They explain the steps required to produce a finished product that will meet factory specifications.

More information

Dewalt Organizer Storage Cabinet Plans

Dewalt Organizer Storage Cabinet Plans Dewalt Organizer Storage Cabinet Plans Version 1.0 How to build a system to perfectly organize you Dewalt storage organizers. With easy to follow step-by-step instructions, you will be able to cut, assemble,

More information

EMAC 001 ACCESS PANEL

EMAC 001 ACCESS PANEL EMAC 001 ACCESS PANEL 900 x 600* 1200 x 600* Picture covers uneven edges Beaded can be taped and jointed for skimming Ensure the structural opening (panel size +10mm) is lined with timber or steel section.

More information

SURFACE CASTING METHOD: For Molds & Core Boxes. Presented by: Hapco Inc.

SURFACE CASTING METHOD: For Molds & Core Boxes. Presented by: Hapco Inc. SURFACE CASTING METHOD: For Molds & Core Boxes Presented by: Hapco Inc. RAPIDFIL Detailed Specifications STEP 1 SPACER LAYER Apply a layer of ¼ foam to create a uniform ¼ thickness around the pattern.

More information