Installation and Operating Instructions

Size: px
Start display at page:

Download "Installation and Operating Instructions"

Transcription

1 Man.rev...0 Installation and Operating Instructions Contents : TECHNICAL DATA OPERATION, CONSTRUCTION AND PARTS LIST DIMENSIONS MOUNTING PROTECTION KITS. SPECIAL INSTRUCTIONS FOR THE SAFE USE DOCUMENTS Technical Specifications : G Installation and Operating Instructions : We reserve the right to make modifications to this document without noticel modifications without prior notice. PASVE is the registered trademark of Satron Instruments Inc. Satron Instruments Inc. P.O. Box, FIN-0 Tampere Tel Telefax info@satron.com

2 Technical data PASVE SC/SF/SH/SP/ST is a miniature ball valve which readily accepts a commercially available hygienic rubber septum. The PASVE SC/SF/SH/SP/ST provides you with the opportunity to safely take hygienic samples from your process without interrupting the process. The PASVE SC/SF/SH/SP/ST can be used in any industrial process where it is necessary obtain a sample from the process which is not influenced or contaminated from any outside disturbances. The PASVE SC/SF/SH/SP/ST is a member of the Satron PASVE Series, which is commonly used with ph probes, oxygen sensors and Satron's high precision patented pressure and level transmitters. Technical Specifications 0 Coupling part, thickness. mm O-ring Ø,x, NBR Locking screw Mx DIN A Retaining screw Mx0 DIN A V0000 V0000 V0000 V0000 V0000 T00 T00 T00 V0000 V000 V V T00 Material Housing: AISIL : PTFE / Silicone rubber seal PASVE SC Max. process pressure: 0 bar (0 psi) (subject to type of rubber septum selected) Max. process temperature: 0 C (0 F) (subject to type of rubber septum selected) European Directive Information European Pressure Equipment Directive (PED) (//EC) - Sound Engineering Practice 0 Coupling part, thickness 0 mm O-ring Ø,x, NBR Locking screw Mx DIN A Retaining screw Mx0 DIN A V0000 V0000 V0000 V0000 V0000 T00 T00 T00 T00 V000 V V T00. Operation, construction and parts list PASVE SC - 0 Operation Position for taking a sample Taking a sample Changing of the rubber septum 0 Coupling part O-ring Ø,x, NBR Locking screw Mx DIN A Retaining screw Mx0 DIN A V0000 V0000 V0000 V0000 V0000 T00 T00 T00 V000 V000 V V T00 PROCESS PASVE SP

3 Dimensions (in mm) PASVE ST - Tuchenhagen, sizes DN/DN and DN0/DN0 0 Coupling part, DN/DN Coupling part, DN0/DN0 O-ring Ø,x, NBR Locking screw Mx DIN A Retaining screw Mx0 DIN A O-ring Øx EPDM O-ring Øx EPDM V0000 V0000 V0000 V0000 V0000 T00 T00 T00 T00 V000 V000 V V T SC =, SC-0 = 0 Ø0 PASVE SC and SC - 0 DN/ = Ø0, DN0/0 = Ø PASVE SH (Tri-Clamp) - Sizes DN / and DN0 / PASVE SH - Tri-Clamp, sizes DN/ and DN0/ 0 Coupling part, Tri-Clamp / Coupling part, Tri-Clamp 0/ O-ring Ø,x, NBR Locking screw Mx DIN A Retaining screw Mx0 DIN A V0000 V0000 V0000 V0000 V0000 T00 T00 T00 V000 V000 V000 V V T00 Ø Ø Ø0 Ø Ø Ø PASVE SF - Flange SF D0 APV-FN-0 0 Coupling part, flange SF D0 APV-FN-0 Coupling part, flange SF D0 O-ring Ø,x, NBR Locking screw Mx DIN A Retaining screw Mx0 DIN A V0000 V0000 V0000 V0000 V0000 T00 T00 T00 T000 T00 V000 V V T00 PASVE ST (Tuchenhagen) - Size DN0 / 0 PASVE SP PASVE ST (Tuchenhagen) - Size DN / - Flange SF D0 Seal kit for Pasve SC, SF, SH, SP and ST Incl. parts no., and M0000 Ø

4 Dimensions (in mm). Upgrade kit PASVE SF - Flange SF D0-0mm outer diameter Ø0 0 x 0 Ø Valve body LV O-ring Ø, x, NBR V0000 T00 T00 T00 V V000 T00 Upgrade kit, assembly M000 PASVE SF - Flange SF D0 APV-FN-0-0mm outer diameter, Ø, Ø Ø0, Ø0 0 x 0 Ø. Mounting of PASVE SC/SP Locking screw M Locking screw M Protection kit a PTFE gasket PTFE gasket Rubber gasket Rubber gasket a a PASVE SC. Drill a Ø0mm hole for the valve (type SC). Slacken locking grub screw. Unscrew the coupling part () from the body () right hand thread and remove all parts from coupling.. Weld the coupling part () taking care not to distort it - use small welding rod and multiple passes to minimise heating. re assemble the PASVE S valve assembly into the coupling as shown PASVE SP T-pipe Mounting of PASVE SH and ST Pull-out sleeve Spring Locking sleeve Retaining screw Mx DIN A T00 T00 T re tighten the assembly- right hand thread - by hand. Do not over tighten or use tools to tighten as this will damage the valve. PASVE SH and ST will be fixed with a clamp to the coupling. Protection kit, assembly M000. Tighten the locking screw

5 Special instructions for the safe use. Septum rubber replacing Please note: Pictures illustrate operational principles only, not accurate drawings.. Safe sampling Take the sample. Replace the rubber septum Turn the valve to the sample taking position Figure - Figure - Figure -, Pasve in sample taking position Pasve in the sample taking position Remove the sampling syringe from the valve Figure - Figure - Open the shut-off plug by turning it counterclockwise! Turn the valve to the maitenance positition Install the special nut V by turning it counterclockwise! -First screw the special nut V lightly in -When it reaches the rubber septum tighten the nut - turns Do not remove any other parts! Figure - Figure -0 Figure - Install the shut-off plug by turning it clockwise! Remove the special nut V by rotating it clockwise! Push the sampling syringe through the rubber septum. Figure - Figure - Turn the valve to the maintenance position Figure - Figure - Figure -

6 ..0. Changing of the gasket and the rubber seal. Reinstall the top part of the valve on the coupling part by turning it clockwise! Tighten it by hand, don't use any tools.. Open the locking screw.. Separate the top part of the valve from the coupling part by turning it counterclockwise!. Tighten the locking screw. Figure - Figure - Top parts of the valve Coupling part Figure - 0

M1 series 2 way ball valve with integrated Praher Labeling System

M1 series 2 way ball valve with integrated Praher Labeling System General: Material: PVC-U Seal material: EPDM / FPM Ball seating joint: PTFE Dimensions: DN10 DN50 d16 d63 d3/8 d2 Connection types: Solvent socket DIN / ASTM / JIS Solvent spigot DIN Threaded socket BSP

More information

SATRON VB Pressure Transmitter

SATRON VB Pressure Transmitter SATRON VB pressure transmitter belongs to the series V transmitters. SATRON VB is userfriendly, through the ball valve mounted transmitter which is used for 04 kpa... 03 MPa ranges. The transmitter communicates

More information

Differential Pressure Transmitter using two separate pressure sensors. On the measuring ranges 7,5:1-25:1: max.span

Differential Pressure Transmitter using two separate pressure sensors. On the measuring ranges 7,5:1-25:1: max.span SATRON VDU differential pressure transmitter belongs to Vseries transmitters. SATRON VDU differential pressure transmitter is used from kpa to 3 MPa ranges (static pressure + measuring range). It is a

More information

Diesel Pile Hammer D30-32 Part # 66508

Diesel Pile Hammer D30-32 Part # 66508 Diesel Pile Hammer D30-32 Part # 66508 2 Diesel Pile Hammer D30-32 Part # 66508 Pos Order No Pg Description Qty 66508 Diesel Pile Hammer D30-32 cmpl 1 1 108742 4 Cylinder Lower Part cmpl 1 2 60151 Inner

More information

Installation and Setting-Up Instructions Spare Parts List

Installation and Setting-Up Instructions Spare Parts List M, revision 3 Installation and Setting-Up Instructions Spare Parts List Contents: INSTALLATION. Mechanical installation. Electrical connections SETTING UP. Using the Hart 75 user interface. Setting up

More information

Service instructions. CR, CRI, CRN 10, 15 and /60 Hz 1/3~

Service instructions. CR, CRI, CRN 10, 15 and /60 Hz 1/3~ Service instructions CR, CRI, CRN 10, 15 and 20 50/60 Hz 1/~ 1. Type identification... 2 1.1 Nameplate... 2 1.2 Type key... 1. Code for shaft seal... 4 2. Tightening torques and lubricants... 5. Service

More information

Insertion Transducer On-line Install Instruction

Insertion Transducer On-line Install Instruction LOGO Insertion Transducer On-line Install Instruction Shanghai Dynameters Co., Ltd www.dynameters.com Insertion Transducer Installation Manual Installation steps 1. Locate Installing point 2. Weld mounting

More information

25000 Series Lo-T TM Butterfly Control Valve Instructions

25000 Series Lo-T TM Butterfly Control Valve Instructions November 2001 25000 Series Lo-T TM Butterfly Control Valve Instructions Instruction No. 25.1:IM PRELIMINARY STEPS Before installation, note the flow direction arrow on the valve body. The flow should enter

More information

Diesel Hammer Model D19-42 Part #

Diesel Hammer Model D19-42 Part # Diesel Hammer Model D19-42 Part # 120491 2 Diesel Pile Hammer Part # 120941 Pos Order No. Pg Description Qty 120941 Diesel Pile Hammer D19-42 (Bauer MNR:426514) 1 160198 4 Cylinder Lower Part cmpl 1 2

More information

GWR2 Installation guide: Guided Wave Radar

GWR2 Installation guide: Guided Wave Radar GWR2 Installation guide: Guided Wave Radar -1-4-wire TDR-Sensor with single rod or coaxial probe for continuous level measurement and point level detection in liquids, with analog and switching output.

More information

This product is designed for a water supply pressure range of 20 psi (137kPa) minimum to 80psi (550 kpa) maximum.

This product is designed for a water supply pressure range of 20 psi (137kPa) minimum to 80psi (550 kpa) maximum. We appreciate your commitment to Kohler quality. Please take a few minutes to review this manual before you start installation. If you encounter any installation or performance problems, please don t hesitate

More information

Magnetic level indicators made in Australia under licence to Weka AG of Switzerland.

Magnetic level indicators made in Australia under licence to Weka AG of Switzerland. ABN 24 080 175 293 PO Box 212 Caringbah NSW 1495 Sydney Australia ph: +61 (0)2 9542 8977 fx: +61 (0)2 9542 7978 www.controlcomponents.com.au Magnetic level indicators made in Australia under licence to

More information

Mounting Accessories. Installation Guide. VIVOTEK SD83XXE Speed Dome

Mounting Accessories. Installation Guide. VIVOTEK SD83XXE Speed Dome VIVOTEK SD83XXE Speed Dome Mounting Accessories AM-116/117 Pendant Pipe AM-118 Pendant Head AM-221 Gooseneck AM-231 Parapet Mount AM-519 Pendant Adaptor Installation Guide Corresponding part numbers: AM-116:

More information

installation instructions WC Frame 1180mm with Dual Flush Cistern

installation instructions WC Frame 1180mm with Dual Flush Cistern installation instructions WC Frame 1180mm with Dual Flush Cistern (C,D,E) K F/G N L M 12 13 14 16 1 2 11 A 5 6 Q O Y 3 C 10 E D B P,Z,AA R T V S 4 U 2 No. Part no. Description Quantity A WC Frame with

More information

Drilling machine Drilling machine for under pressure drilling Page Q 2/1 Motorised drilling machine Page Q 2/2

Drilling machine Drilling machine for under pressure drilling Page Q 2/1 Motorised drilling machine Page Q 2/2 TOOLS Page Q 2 Drilling machine Drilling machine for under pressure drilling Page Q 2/1 Motorised drilling machine Page Q 2/2 Page Q 3 Changeable carbide drill (WHM) Page Q 3/1 Drilling machine Tonisco

More information

RG REPAIR GUIDELINE 10/23/2015. Repair Description: Tools Required: Step List: Approximate time: minutes

RG REPAIR GUIDELINE 10/23/2015. Repair Description: Tools Required: Step List: Approximate time: minutes Repair Description: Replace BP54000/BP55000 with PA54000 for repairs Tools Required: ) # Philips head screwdriver or Drill ) Small, flat head screwdriver ) Dremel Tool or ¼ round file 4) Caulking Gun 5)

More information

Series GWL - Radar Level Transmitter for Liquids

Series GWL - Radar Level Transmitter for Liquids TM Series GWL - Radar Level Transmitter for Liquids Bulletin L-GWL Specifications - Installation and Operating Instructions 4-7/16 [112.63] Ø3-19/32 [90.96] 1-9/16 [39.42] 5-19/32 [142.07] 3-17/32 [89.95]

More information

installation instructions

installation instructions installation instructions Easi-Plan WC Frame 820mm with Dual Flush Cistern ref: EPWC-05-1005 Easi-Plan WC Frame 980mm with Dual Flush Cistern ref: EPWC-05-1505 EASI-PLAN installation instructions Parts

More information

ECT Applications. Features

ECT Applications. Features ECT 847 Industrial Pressure Transmitter Swiss based Trafag is a leading international supplier of high quality sensors and monitoring instruments for measurement of and temperature. The economical transmitter

More information

AIR KIT 3. Heavy-Duty Public Bike Pump

AIR KIT 3. Heavy-Duty Public Bike Pump Heavy-Duty Public Bike Pump The Air Kit 3 is designed for heavy-duty, repeated public use. The waterproof gauge and burly construction mean that this pump will continue to work long after others have failed.

More information

A Higher Level of Performance. Data Sheet. Series Pressure and Level Transmitters. For more information, please visit >

A Higher Level of Performance. Data Sheet. Series Pressure and Level Transmitters. For more information, please visit > A Higher Level of Performance Data Sheet Series 000 Pressure and Level Transmitters For more information, please visit > www.hawkmeasure.com Series 000 000-SAN Cable with separate electronics Description

More information

ASOLA - THETA ISTRUZIONI DI MONTAGGIO FITTING INSTRUCTIONS INSTRUCTIONS DE MONTAGE INSTRUCCIONES DE MONTAJE MONTAGEANLEITUNG. IMPBAT Rev.

ASOLA - THETA ISTRUZIONI DI MONTAGGIO FITTING INSTRUCTIONS INSTRUCTIONS DE MONTAGE INSTRUCCIONES DE MONTAJE MONTAGEANLEITUNG. IMPBAT Rev. ASOLA - THETA I F E D ISTRUZIONI DI MONTAGGIO FITTING INSTRUCTIONS INSTRUCTIONS DE MONTAGE INSTRUCCIONES DE MONTAJE MONTAGEANLEITUNG IMPBAT08-2 - Rev. 00 "THETA" FITTING INSTRUCTIONS SUB-FRAME Correct

More information

Fisher 667 Diaphragm Actuators Size 80 and 100

Fisher 667 Diaphragm Actuators Size 80 and 100 Instruction Manual 667 Size 80 and 100 Actuators Fisher 667 Diaphragm Actuators Size 80 and 100 Contents Introduction... 1 Scope of Manual... 1 Description... 2 Specifications... 2 Maximum Pressure Limitations...

More information

H2-50 Hydrogen Generator Field Update

H2-50 Hydrogen Generator Field Update This field update is intended to provide extra protection in the event the H2 generation cell fractures or cracks. Please add the additional parts to your H2-50 as soon as possible. Please take a digital

More information

Technical Data Measuring principle Thick-film-on-ceramic 25 C typ. ± 0.3 % FS typ. (± 0.5 % FS typ., ± 1 % FS typ.)

Technical Data Measuring principle Thick-film-on-ceramic 25 C typ. ± 0.3 % FS typ. (± 0.5 % FS typ., ± 1 % FS typ.) ECT 87 Industrial Pressure Transmitter Swiss based Trafag is a leading international supplier of high quality sensors and monitoring instruments for measurement of and temperature. The economic transmitter

More information

JARVIS. Model Brisket Scissor EQUIPMENT... TABLE OF

JARVIS. Model Brisket Scissor EQUIPMENT... TABLE OF Model 423-17 Brisket Scissor EQUIPMENT SELECTION... Ordering No. TABLE OF CONTENTS... Page Model 423--17... 4037003 Air Filter / Regulator / Lubricator 3022003 Air Hose Assembly... 3059018 Balancer...

More information

Remarks: Before Installation, please read the instruction carefully.

Remarks: Before Installation, please read the instruction carefully. 60 cm antenna Z24A60T37301 Remarks: Before Installation, please read the instruction carefully. This instruction book is for the installation of 0.6m ultra-high performance microwave antenna. Installation,

More information

The transducer component converts the measured signal and displays the actual value.

The transducer component converts the measured signal and displays the actual value. Digital inductive conductivity transmitter System Integration Provides low Total Cost of Ownership PEEK/PPA version for CIP applications TEACH IN and SIMULATION Function Approval PVDF Version PEEK Version

More information

4" (DN 100) 5RET Tank Car Fire-Tite Bottom Unloading Valves. Installation, Maintenance and Operating Instructions

4 (DN 100) 5RET Tank Car Fire-Tite Bottom Unloading Valves. Installation, Maintenance and Operating Instructions 4" (DN 100) 5RET Tank Car Fire-Tite Bottom Unloading Valves Installation, Maintenance and Operating Instructions IMO-R14 11/2013 2 IMO-R14 Table of Contents 1 GENERAL....................................

More information

Digital inductive conductivity transmitter

Digital inductive conductivity transmitter Digital inductive conductivity transmitter Optimal solution for conductivity measurements in difficult fluids (polluted, dirty,...) PEEK/PPA version for CIP applications Large range of process connections

More information

Installation Instructions

Installation Instructions Installation Instructions For 4 foot / 1.2m Diameter Ultra-high Performance Antenna Model ADxxG-4-T2 Before Installation, please read the instructions carefully. This instruction guide covers the installation

More information

LU6X-130 Instructions and Parts List (including LU6X Basic) Operating Instructions

LU6X-130 Instructions and Parts List (including LU6X Basic) Operating Instructions LORTONE LU6X-130 Item # 061-092 LU6X Basic Item # 061-090 LU6X-130 Instructions and Parts List (including LU6X Basic) Operating Instructions Introduction The LU6X is one the most versatile pieces of equipment

More information

Magnetic-inductive flow meter. PITe / UMF2. Technical Datasheet. Maintenance-free Nearly no pressure drop Robust design Easy installation and start-up

Magnetic-inductive flow meter. PITe / UMF2. Technical Datasheet. Maintenance-free Nearly no pressure drop Robust design Easy installation and start-up Magnetic-inductive flow meter Technical Datasheet PITe / UMF2 Maintenance-free Nearly no pressure drop Robust design Easy installation and start-up Subject to change without notice 1 Function An electrically

More information

installation instructions WC Frame 820mm with Dual Flush Cistern _INST

installation instructions WC Frame 820mm with Dual Flush Cistern _INST installation instructions WC Frame 820mm with Dual Flush Cistern 1 2014-0010-0820_INST J 8 9 E/F M 7 K L 1 2 6 5 P A U C D B Q 4 T 3 N O W S R 2 No. Part no. Description Quantity A WC Frame with Dual Flush

More information

Drilling machine for use on branch saddles fused. Instructions for assembly and use

Drilling machine for use on branch saddles fused. Instructions for assembly and use Drilling machine for use on branch saddles fused Instructions for assembly and use DRILLING MACHINE FOR USE ON BRANCH SADDLES FUSED ON POLYETHYLENE PIPELINES FOR PRESSURE AND NON-PRESSURE USE Ø 90 1000

More information

MUELLER. Improved, Centurion Series, Modern Improved, and 107. Fire Hydrants. Inserting Extention Sections. Reliable Connections

MUELLER. Improved, Centurion Series, Modern Improved, and 107. Fire Hydrants. Inserting Extention Sections. Reliable Connections insertion Instructions manual MUELLER Improved, Centurion Series, Modern Improved, and 107 table of contents PAGE Centurion Series Fire Hydrant Adding an Extention 2-3 Improved Fire Hydrant Inserting Extention

More information

WILLIS WALL-MOUNT FAUCET INSTALLATION

WILLIS WALL-MOUNT FAUCET INSTALLATION SKU(s): 924620 BEFORE YOU BEGIN We recommend consulting a professional if you are unfamiliar with installing bathroom fixtures and plumbing. Signature Hardware accepts no liability for any damage to the

More information

ISSUE MODIF. ORDER NO. WEEK ISSUE MODIF. ORDER NO. WEEK ISSUE MODIF. ORDER NO. WEEK 01 SME SME SME

ISSUE MODIF. ORDER NO. WEEK ISSUE MODIF. ORDER NO. WEEK ISSUE MODIF. ORDER NO. WEEK 01 SME SME SME 1. Summary The still pipe used with Rosemount 5900 LPG/LNG antenna is not supplied by RTR, but is to be manufactured by the customer according to the RTR drawing D9240041-910 or D7000001-466. Additional

More information

Installation and Setting-Up Instructions Spare Parts List

Installation and Setting-Up Instructions Spare Parts List M, revision 5..0 Installation and Setting-Up Instructions Spare Parts List Contents: INSTALLATION. Mechanical installation. Electrical connections SETTING UP. Using the 75 user interface. Setting up through

More information

Installation and Setting-Up Instructions Spare Parts List

Installation and Setting-Up Instructions Spare Parts List M, revision Installation and Setting-Up Instructions Spare Parts List Contents: INSTALLATION. Mechanical installation. Electrical connections SETTING UP. Applications/Liquid level measurement. Using the

More information

OTECO INC. MODEL ,000 PSI 4-1/16 PORT DM GATE VALVE MAINTENANCE MANUAL

OTECO INC. MODEL ,000 PSI 4-1/16 PORT DM GATE VALVE MAINTENANCE MANUAL Page 1 of 7 OTECO INC. MODEL 45 4 5,000 PSI 4-1/16 PORT DM GATE VALVE MAINTENANCE MANUAL Page 2 of 7 TABLE OF CONTENTS 1. Assembly Blowout 2. Repair Kit Contents & Technical Specifications 3. Disassembly

More information

Digital conductivity transmitter

Digital conductivity transmitter Digital conductivity transmitter Compact version with integrated conductivity electrodes Remote version with seperated transmitter for short (15 ft.) or long (1500 ft.) distance Commissioning is easy due

More information

EN 1092 PN 10 EN 1092 PN 16 JIS B K ANSI B16.5 Class 150 ANSI B16.47 Class 150 BS 10 Table D

EN 1092 PN 10 EN 1092 PN 16 JIS B K ANSI B16.5 Class 150 ANSI B16.47 Class 150 BS 10 Table D HG EN 1092 PN 10 EN 1092 PN 16 JIS 2238 10K ANSI 16.5 Class 150 ANSI 16.47 Class 150 S 10 Table D Stafsjö s knife gate valve HG is a bi-directional valve, particularly well suited for severe operating

More information

FBX1104P FBX1104 FBX1106P FBX1106

FBX1104P FBX1104 FBX1106P FBX1106 FBX1104P FBX1104 FBX1106P FBX1106 Second edition : September 2004 No. 040037 INTRODUCTION Thank you for your purchasing Kansai Special's FBX Series. Read and study this instruction manual carefully before

More information

...thoroughly tried and tested!

...thoroughly tried and tested! ...thoroughly tried and tested! Tapping and bushing with EWE tools www.ewe-armaturen.de Installation and operating instructions for EWE drilling units 1. Details of product 1.1. Application field EWE tapping

More information

The Virgo/Libra Steam Engine

The Virgo/Libra Steam Engine The Virgo/Libra Steam Engine Congratulations on becoming the owner of a Virgo or Libra Steam Engine. With careful use and maintenance it will give many years of satisfying performance. Contents 1) Notes

More information

Temperature Sensor with M12 hygienic

Temperature Sensor with M12 hygienic 1 Product Information TFP-42, -52, -62, -162, -182 Temperature Sensor with M12 hygienic FOOD Application / Specified Usage Authorizations Temperature Measurement in pipes DN15...DN80 Temperature measurement

More information

Remarks: Before Installation, please read the instruction carefully.

Remarks: Before Installation, please read the instruction carefully. 30 cm antenna Z24A30T37301 Remarks: Before Installation, please read the instruction carefully. This instruction book is for the installation of 0.3m ultra-high performance microwave antenna. Installation,

More information

Engineering Data Single Reduction Parts List Item # Description Basic Single Reduction Unit 1. Gear Housing 2. Pipe Plug 3. Vent Plug 4. Splash Guard

Engineering Data Single Reduction Parts List Item # Description Basic Single Reduction Unit 1. Gear Housing 2. Pipe Plug 3. Vent Plug 4. Splash Guard Engineering Data Single Reduction Parts List Item # Description Basic Single Reduction Unit 1. Gear Housing 2. Pipe Plug 3. Vent Plug 4. Splash Guard 5. Input Cover 6. O-Ring 7. Hex Head Cap Screw 8. Input

More information

MUELLER. Improved, Centurion Series, Modern Improved, and 107. Fire Hydrants. Inserting Extension Sections. Reliable Connections

MUELLER. Improved, Centurion Series, Modern Improved, and 107. Fire Hydrants. Inserting Extension Sections. Reliable Connections insertion Instructions manual MUELLER Improved, Centurion Series, Modern Improved, and 107 table of contents PAGE Centurion Series Fire Hydrant Adding an Extension 2-3 Improved Fire Hydrant Inserting Extension

More information

PSI COMPAKT SEALS AND WALL SLEEVES WITH FIXED/LOOSE FLANGE

PSI COMPAKT SEALS AND WALL SLEEVES WITH FIXED/LOOSE FLANGE PSI COMPAKT SEALS AND WALL SLEEVES WITH FIXED/LOOSE FLANGE IN GALVANIZED OR STAINLESS STEEL FOR BUILDINGS WITH OR WITHOUT SEALING SHEETS IN SPLIT VERSION FOR RETROFITTING WWW.PSI-PRODUCTS.COM 37 GENERAL

More information

GH BETTIS SERVICE INSTRUCTIONS DISASSEMBLY & REASSEMBLY FOR MODEL F10207 DOUBLE ACTING HYDRAULIC ACTUATOR

GH BETTIS SERVICE INSTRUCTIONS DISASSEMBLY & REASSEMBLY FOR MODEL F10207 DOUBLE ACTING HYDRAULIC ACTUATOR GH BETTIS SERVICE INSTRUCTIONS DISASSEMBLY & REASSEMBLY FOR MODEL F10207 DOUBLE ACTING HYDRAULIC ACTUATOR PART NUMBER: 074960 REVISION: "A" RELEASE DATE: NOVEMBER, 1991 Page 1 of 6 1.0 INTRODUCTION 1.1

More information

MODEL D DIESEL PILE HAMMER

MODEL D DIESEL PILE HAMMER AMERICAN PILEDRIVING EQUIPMENT, INC. MODEL D125-42 DIESEL PILE HAMMER SPARE PARTS BOOK Corporate Office 7032 S. 196th Street Kent, WA, USA 98032 Tel: 1-800-248-8498 Tel: 1-253-872-0141 Fax: 1-253-872-8710

More information

SA seal Sanitary diaphragm seal type

SA seal Sanitary diaphragm seal type SA seal Sanitary diaphragm seal type Design description Badotherm sanitary seals are designed for pressure, level and flow measurements in food & beverage and pharmaceutical industries where the formation

More information

High Speed Air Turbine Handpiece

High Speed Air Turbine Handpiece OPERATION MANUAL High Speed Air Turbine Handpiece Please read this Operation Manual carefully before use and file for future reference. Handpiece should not be used with friction grip burs exceeding 18.5

More information

CAT GB. Quick-release couplings and accessories for Air Conditioning & Refrigeration. UNI EN ISO 9001 Cert. n 2905 ISO/TS 16949

CAT GB. Quick-release couplings and accessories for Air Conditioning & Refrigeration. UNI EN ISO 9001 Cert. n 2905 ISO/TS 16949 CAT. 0118-GB Quick-release couplings and accessories for Air Conditioning & Refrigeration UNI EN ISO 9001 Cert. n 905 ISO/TS 16949 Quick-release couplings and accessories for Air Conditioning & Refrigeration

More information

Version: 1.0 Revised: 6/8/2011. CBU Assembly Instructions Manual

Version: 1.0 Revised: 6/8/2011. CBU Assembly Instructions Manual CBU Assembly Instructions Manual Contents 1 General... 3 2 Package... 4 2.1 Packing order... 4 2.2 Unpacking... 5 3 Assembly of the body... 6 3.1 General... 6 3.2 Mounting base drilling chart... 8 3.3

More information

HARDINGE Installation booklet For:

HARDINGE Installation booklet For: HARDINGE Installation booklet For: L Flange Nose Dead-Length Collet Adaptation Chucks Draw Collet Read the enclosed instructions and recommendations before any installations WARRANTY & RETURN PROCEDURES

More information

Maintenance Information

Maintenance Information 16601023 Edition 2 January 2014 Air Impact Wrench 2705P1 Maintenance Information Save These Instructions Product Safety Information WARNING Failure to observe the following warnings, and to avoid these

More information

MKS. MKS Series MKS 40 MKS 45 MKS 50 MKS 55 MKS 60 MKS 65. Repair Manual

MKS. MKS Series MKS 40 MKS 45 MKS 50 MKS 55 MKS 60 MKS 65. Repair Manual MKS Series MKS 40 MKS 45 MKS 50 MKS 55 MKS 60 MKS 65 Repair Manual INDEX. INTRODUCTION 3 2. REPAIR INSTRUCTIONS 3 2. Crank Mechanism Repair...3 2.. Crank Mechanism Disassembly...4 2..2 Crank Mechanism

More information

Level transmitters Series LTDR TDR guided radar level transmitter for liquids and solids

Level transmitters Series LTDR TDR guided radar level transmitter for liquids and solids Level transmitters Series LTDR TDR guided radar level transmitter for liquids and solids Level measurement independent of changing process conditions (density, conductivity, temperature, pressure, ) Innovative

More information

MALEKO WALL-MOUNT FAUCET INSTALLATION

MALEKO WALL-MOUNT FAUCET INSTALLATION SKU(s): 934146 BEFORE YOU BEGIN We recommend consulting a professional if you are unfamiliar with installing bathroom fixtures and plumbing. Signature Hardware accepts no liability for any damage to the

More information

Series B Medical Gas Service Outlet Upgrade Kits

Series B Medical Gas Service Outlet Upgrade Kits Installation Instructions Series B Medical Gas Service Outlet Upgrade Kits For additional information concerning operation of Puritan Bennett Series B Quick-Connect Outlet Valves, refer to Operating Instructions

More information

PORTABLE PULL TESTER

PORTABLE PULL TESTER 2425 West Vineyard Avenue, Escondido, California 92029-222 Phone: (800) 284-4460 Fax: (760) 746-4295 PORTABLE CABLE TERMINAL PULL TESTER AT520CT (Revised July 2003) AT520CT Portable Cable Terminal Pull

More information

Rosemount 5408 and 5408:SIS Level Transmitters

Rosemount 5408 and 5408:SIS Level Transmitters Quick Start Guide 00825-0100-4408, Rev AD March 2018 Rosemount 5408 and 5408:SIS Level Transmitters Cone Antenna Quick Start Guide March 2018 1 About this guide This Quick Start Guide provides basic guidelines

More information

FM125 & FM126 Service Guide

FM125 & FM126 Service Guide FM125 & FM126 Service Guide FM125-0022 & FM125-0024 Repair Kit 1 2 3 4 #1-1 Pc. FM125-5012 Ball Carrier Installation Tool (FM125-0022 Only) #2-2 Pcs. P5-287-R0 O-Ring #3-2 Pcs. P5-067-R2 O-Ring #4-1 Pc.

More information

Flow Measurement SITRANS F M

Flow Measurement SITRANS F M Overview Mode of operation The flow measuring principle is based on Faraday s law of electromagnetic induction according to which the sensor converts the flow into an electrical voltage proportional to

More information

BETTIS SERVICE INSTRUCTIONS FOR MODELS G01 THROUGH G10 SERIES HYDRAULIC SPRING RETURN ACTUATORS WITH M11 HYDRAULIC OVERRIDE

BETTIS SERVICE INSTRUCTIONS FOR MODELS G01 THROUGH G10 SERIES HYDRAULIC SPRING RETURN ACTUATORS WITH M11 HYDRAULIC OVERRIDE ENGLISH LANUAGE BETTIS SERVICE INSTRUCTIONS FOR MODELS G01 THROUGH G10 SERIES HYDRAULIC SPRING RETURN ACTUATORS WITH M11 HYDRAULIC OVERRIDE PART NUMBER: 127072E REVISION: A DATE: December 2001 Page 1 of

More information

w w w. h d o n l i n e s h o p. d e TIMKEN BEARING CONVERSION TOOL GENERAL INSTALLATION -J04672 REV Kit Number Models

w w w. h d o n l i n e s h o p. d e TIMKEN BEARING CONVERSION TOOL GENERAL INSTALLATION -J04672 REV Kit Number Models -J067 REV. 008-07- GENERAL Kit Number 8-08 Models TIMKEN BEARING CONVERSION TOOL For model fitment information, see the P&A Retail Catalog or the Parts and Accessories section of www.harley-davidson.com

More information

400 SERIES GRINDER PUMPS 41502, 42202,43302, AND MODELS

400 SERIES GRINDER PUMPS 41502, 42202,43302, AND MODELS Section: MOYNO 500 PUMPS Page: 1 of 6 Date: March 1, 1998 SERVICE MANUAL MOYNO 500 PUMPS 400 SERIES GRINDER PUMPS 41502, 42202,43302, AND 44402 MODELS DESIGN FEATURES Housing: Cast iron Pump Rotor: Chrome

More information

B-Too Drilling and Tapping Machine Instruction and Maintenance Manual

B-Too Drilling and Tapping Machine Instruction and Maintenance Manual B-Too Drilling and Tapping Machine Instruction and Maintenance Manual Thank you for your purchase of the B-Too Drilling and Tapping Machine. Please read and understand this short operation manual. Our

More information

2-jaw parallel self-centering pneumatic gripper (series GM)

2-jaw parallel self-centering pneumatic gripper (series GM) GM -jaw parallel self-centering pneumatic gripper (series GM) Double acting. The rugged construction lends itself to heavy duty applications for a trouble free long life without maintenance. Wide choice

More information

Service Parts List AA4V90

Service Parts List AA4V90 Service Parts List AA4V90 Series 1 06.96 Ordering of AA4V Parts For Rexroth to supply the correct parts for your unit, please include all of the following information with your parts order. TYPE CODE TYPE

More information

.1 Materials and installation for steel piping, valves and fittings for hydronic systems in building services piping..2 Related Sections.

.1 Materials and installation for steel piping, valves and fittings for hydronic systems in building services piping..2 Related Sections. Issued 2006/08/01 Section 15183 Hydronic Systems: Steel Page 1 of 6 PART 1 GENERAL 1.1 SUMMARY.1 Section Includes..1 Materials and installation for steel piping, valves and fittings for hydronic systems

More information

Page 1. SureMotion Quick-Start Guide: LARSACC_QS 1st Edition - Revision A 03/15/16. Standard Steel Bolt/Screw Torque Specifications

Page 1. SureMotion Quick-Start Guide: LARSACC_QS 1st Edition - Revision A 03/15/16. Standard Steel Bolt/Screw Torque Specifications R K C T I Repair Kit Product Compatibility Repair Kit # Linear Actuator Assembly # LARSACC-013 LARSACC-014 LARSD2-08T12BP2C (12-in travel) LARSD2-08T24BP2C (24-in travel) C P I R K 1 ea Ball Screw with

More information

Installation Instructions

Installation Instructions MOUNT TUB SYSTEMS HAMPTON TRIM KIT T980.702 Installation Instructions T980.702 T980.712 T980.722 T980.732 Thank you for selecting American-Standard...the benchmark of fine quality for over 100 years. To

More information

Pharma-Temperature Sensor M12 hygienic

Pharma-Temperature Sensor M12 hygienic SENSORS FOR FOOD AND BIOPHARMA. Product Information TFP-42P, -52P, -62P, -162P, -182P PHARMA Pharma-Temperature Sensor M12 hygienic Application/Specified usage Temperature measurement in pipes DN15...DN80

More information

Digital flow ELEMENT transmitter for continuous flow measurement

Digital flow ELEMENT transmitter for continuous flow measurement ELEMENT Transmitter Digital flow ELEMENT transmitter for continuous flow measurement Type can be combined with... PN10, DN15 to DN400 fluidic process connection Programmable outputs : one or two transistor

More information

Limit switch set BOA-H DN PN 16/25 Material variant EN-GJS LT

Limit switch set BOA-H DN PN 16/25 Material variant EN-GJS LT Assembly instructions 0570.812/04-EN Limit switch set BOA-H DN 15-150 PN 16/25 Material variant EN-GJS-400-18-LT Fig. 1 Exploded view of limit switch set... 2 Fig. 2 Parts list for limit switch set...

More information

ROTUNDA WALL-MOUNT FAUCET INSTALLATION

ROTUNDA WALL-MOUNT FAUCET INSTALLATION SKU(s): 919045 BEFORE YOU BEGIN We recommend consulting a professional if you are unfamiliar with installing bathroom fixtures and plumbing. Signature Hardware accepts no liability for any damage to the

More information

Temperature Sensor with M12 hygienic

Temperature Sensor with M12 hygienic SENSORS FOR AND BIOPHARMA. Product Information TFP-42, -52, -62, -162, -182 Temperature Sensor with M12 hygienic Application / Specified Usage Temperature Measurement in pipes DN15...DN80 Temperature measurement

More information

LPK1550 Hydraulic Crimping Tool 15-ton

LPK1550 Hydraulic Crimping Tool 15-ton SERVICE MANUAL LPK1550 Hydraulic Crimping Tool 15-ton Serial Code FYF Read and understand all of the instructions and safety information in this manual before operating or servicing this tool. Register

More information

2-jaw self centering rocking pneumatic gripper (series GW)

2-jaw self centering rocking pneumatic gripper (series GW) 2-jaw self centering rocking pneumatic gripper (series ) Double acting. Long life and reliability, maintenance free. Various options for fastening. Optional proximity magnetic sensors. Spring closed (-NC)

More information

INDUSTRIAL PRESSURE TRANSMITTER

INDUSTRIAL PRESSURE TRANSMITTER ECT 87 INDUSTRIAL PRESSURE TRANSMITTER Swiss based Trafag is a leading international supplier of high quality sensors and monitoring instruments for measurement of and temperature. The economic transmitter

More information

MUELLER GAS. DH-5/EH-5 Drilling. Reliable Connections. DH-5 Drilling Machine General Information 2. EH-5 Drilling Machine General Information 3

MUELLER GAS. DH-5/EH-5 Drilling. Reliable Connections. DH-5 Drilling Machine General Information 2. EH-5 Drilling Machine General Information 3 operating Instructions manual MUELLER GAS TAble of contents PAGE DH-5 Drilling Machine General Information 2 DH-5/EH-5 Drilling EH-5 Drilling Machine General Information 3 Operating Instructions 4-5 DH-5

More information

2-JAW SELF-CENTERING RADIAL PNEUMATIC GRIPPER (SERIES PS)

2-JAW SELF-CENTERING RADIAL PNEUMATIC GRIPPER (SERIES PS) PS 2-JAW SELF-CENTERING RADIAL PNEUMATIC GRIPPER (SERIES PS) Double-acting radial motion. The gripping force is constant throughout the entire stroke (from 0 to 90, both opening and closing). Lightweight:

More information

In-Line Resistance Thermometers Model TR25

In-Line Resistance Thermometers Model TR25 Electrical Temperature Measurement In-Line Resistance Thermometers Model TR25 WIKA Data Sheet TE 60.25 Applications Food and beverage industry, dairies, drink dispensers and bottling plants, breweries

More information

SERVICE MANUAL CLINTON FEED OFF THE ARM CHAIN CUTTER WITH EXTERNAL AIR DRIVE MODEL 2115FOTA-V FOR UNION SPECIAL 35800, & YAMATO FD-62 ML2115-7A

SERVICE MANUAL CLINTON FEED OFF THE ARM CHAIN CUTTER WITH EXTERNAL AIR DRIVE MODEL 2115FOTA-V FOR UNION SPECIAL 35800, & YAMATO FD-62 ML2115-7A ML2115-7A CLINTON FEED OFF THE ARM CHAIN CUTTER WITH EXTERNAL AIR DRIVE MODEL 2115FOTA-V FOR UNION SPECIAL 35800, 36200 & YAMATO FD-62 SERVICE MANUAL 40-0164-01 ML2115-8E I. GENERAL INFORMATION A. The

More information

Zero Point Clamping System. ZERO lock BALL lock

Zero Point Clamping System. ZERO lock BALL lock Zero Point Clamping System ZERO lock BALL lock kap3 kap 263 Technical information regarding ZERO lock Zero Point Clamping System Application The modularly designed, flexible ZERO lock Zero-Point Clamping

More information

Repair Manual MK40A-MK45A-MK50A MK55A-MK60A-MK65A. Ref Rev.C General Pump is a Member of The Interpump Group

Repair Manual MK40A-MK45A-MK50A MK55A-MK60A-MK65A. Ref Rev.C General Pump is a Member of The Interpump Group MK Repair Manual MK40A-MK45A-MK50A MK55A-MK60A-MK65A General Pump is a Member of The Interpump Group 8 INDEX 1. INTRODUCTION..................................................Page 3 2. REPAIR INSTRUCTIONS...........................................Page

More information

caroma marc newson wall basin mixer

caroma marc newson wall basin mixer caroma marc newson wall basin mixer water efficient tapware (nominal flow rate = 5 L/min) PLUMBERS INSTALLATION INSTRUCTIONS IS1213A(07/12) Important Information Brazed connections should NOT be made directly

More information

SGP-S - Compact Parallel Gripper

SGP-S - Compact Parallel Gripper 11: Double acting Patented backlash adjusting system. High performance in a compact size. The rugged construction lends itself to heavy-duty applications for a trouble-free long life without maintenance.

More information

thoroughly tried and tested! EWE Tapping Valves A single system for all types of pipes

thoroughly tried and tested! EWE Tapping Valves A single system for all types of pipes thoroughly tried and tested! EWE Tapping Valves A single system for all types of pipes www.ewe-armaturen.de EWE Tapping Fittings high-quality products from Germany EWE tapping fittings are the product

More information

Operating, Servicing, and Safety Manual Model # 100 Standard Hydraulic Tubing Notcher Model #100-U Heavy Duty Hydraulic Tubing Notcher

Operating, Servicing, and Safety Manual Model # 100 Standard Hydraulic Tubing Notcher Model #100-U Heavy Duty Hydraulic Tubing Notcher Operating, Servicing, and Safety Manual Model # 100 Standard Hydraulic Tubing Notcher Model #100-U Heavy Duty Hydraulic Tubing Notcher Model # 100 Standard Model #100-U Heavy Duty CAUTION: Read and Understand

More information

ROCK DRILLS Tabor Place, Santa Fe Springs, California, CA 90670, U.S.A.

ROCK DRILLS Tabor Place, Santa Fe Springs, California, CA 90670, U.S.A. S Website: www.apt-tools.com e-mail: info@apt-tools.com TDS-1027 Rev A S TOOL MAINTENANCE & REPAIR INFORMATION FIELD OPERATION: Before use: 1. Fill the reservoir with air tool oil or 10W equivalent for

More information

3 Emergency Breakaway Coupling

3 Emergency Breakaway Coupling SM64227 July 2008 Applicable addition manuals: N/A Aerospace Group Conveyance Systems Division Carter Ground Fueling Maintenance & Repair Manual 3 Emergency Breakaway Coupling Model 64227 Table of Contents

More information

Accessories for sensors

Accessories for sensors Accessories for sensors Mounting and installation Adapters for pressure sensors: Hex AF width 27 ZBM 01 Adapter female thread G1/4 male thread G1/2 B, DIN EN 837-1 Part no.: 257276 Flat seal ring Cu 6.2x17.5x2.0

More information

OPTISENS PH ph sensor. Technical Datasheet

OPTISENS PH ph sensor. Technical Datasheet Technical Datasheet ph sensor High quality and precise glass sensor for usage in water and waste water analysis Special sensor design for harsh applications Low maintenance costs and a long life cycle

More information

TWIN ROD CYLINDERS 6 CONTENTS

TWIN ROD CYLINDERS 6 CONTENTS CAD drawing data catalog is available. ACTUATORS GENERAL CATALOG TWIN ROD CYLINDERS6 CONTENTS TWIN ROD CYLINDERS 6 Features 745 Specifications/Order Codes 747 Inner Construction and Major Parts 748 Dimensions

More information

Temperature Sensor with G1/2" hygienic

Temperature Sensor with G1/2 hygienic SENSORS FOR FOOD AND BIOPHARMA. Product Information TFP-41, -44, -51, -54, -61, -161, -164, -181, -184 FOOD Temperature Sensor with G1/2" hygienic Application/Specified usage Temperature Measurement in

More information