1 Man.rev...0 Installation and Operating Instructions Contents : TECHNICAL DATA OPERATION, CONSTRUCTION AND PARTS LIST DIMENSIONS MOUNTING PROTECTION KITS. SPECIAL INSTRUCTIONS FOR THE SAFE USE DOCUMENTS Technical Specifications : G Installation and Operating Instructions : We reserve the right to make modifications to this document without noticel modifications without prior notice. PASVE is the registered trademark of Satron Instruments Inc. Satron Instruments Inc. P.O. Box, FIN-0 Tampere Tel Telefax info@satron.com
2 Technical data PASVE SC/SF/SH/SP/ST is a miniature ball valve which readily accepts a commercially available hygienic rubber septum. The PASVE SC/SF/SH/SP/ST provides you with the opportunity to safely take hygienic samples from your process without interrupting the process. The PASVE SC/SF/SH/SP/ST can be used in any industrial process where it is necessary obtain a sample from the process which is not influenced or contaminated from any outside disturbances. The PASVE SC/SF/SH/SP/ST is a member of the Satron PASVE Series, which is commonly used with ph probes, oxygen sensors and Satron's high precision patented pressure and level transmitters. Technical Specifications 0 Coupling part, thickness. mm O-ring Ø,x, NBR Locking screw Mx DIN A Retaining screw Mx0 DIN A V0000 V0000 V0000 V0000 V0000 T00 T00 T00 V0000 V000 V V T00 Material Housing: AISIL : PTFE / Silicone rubber seal PASVE SC Max. process pressure: 0 bar (0 psi) (subject to type of rubber septum selected) Max. process temperature: 0 C (0 F) (subject to type of rubber septum selected) European Directive Information European Pressure Equipment Directive (PED) (//EC) - Sound Engineering Practice 0 Coupling part, thickness 0 mm O-ring Ø,x, NBR Locking screw Mx DIN A Retaining screw Mx0 DIN A V0000 V0000 V0000 V0000 V0000 T00 T00 T00 T00 V000 V V T00. Operation, construction and parts list PASVE SC - 0 Operation Position for taking a sample Taking a sample Changing of the rubber septum 0 Coupling part O-ring Ø,x, NBR Locking screw Mx DIN A Retaining screw Mx0 DIN A V0000 V0000 V0000 V0000 V0000 T00 T00 T00 V000 V000 V V T00 PROCESS PASVE SP
3 Dimensions (in mm) PASVE ST - Tuchenhagen, sizes DN/DN and DN0/DN0 0 Coupling part, DN/DN Coupling part, DN0/DN0 O-ring Ø,x, NBR Locking screw Mx DIN A Retaining screw Mx0 DIN A O-ring Øx EPDM O-ring Øx EPDM V0000 V0000 V0000 V0000 V0000 T00 T00 T00 T00 V000 V000 V V T SC =, SC-0 = 0 Ø0 PASVE SC and SC - 0 DN/ = Ø0, DN0/0 = Ø PASVE SH (Tri-Clamp) - Sizes DN / and DN0 / PASVE SH - Tri-Clamp, sizes DN/ and DN0/ 0 Coupling part, Tri-Clamp / Coupling part, Tri-Clamp 0/ O-ring Ø,x, NBR Locking screw Mx DIN A Retaining screw Mx0 DIN A V0000 V0000 V0000 V0000 V0000 T00 T00 T00 V000 V000 V000 V V T00 Ø Ø Ø0 Ø Ø Ø PASVE SF - Flange SF D0 APV-FN-0 0 Coupling part, flange SF D0 APV-FN-0 Coupling part, flange SF D0 O-ring Ø,x, NBR Locking screw Mx DIN A Retaining screw Mx0 DIN A V0000 V0000 V0000 V0000 V0000 T00 T00 T00 T000 T00 V000 V V T00 PASVE ST (Tuchenhagen) - Size DN0 / 0 PASVE SP PASVE ST (Tuchenhagen) - Size DN / - Flange SF D0 Seal kit for Pasve SC, SF, SH, SP and ST Incl. parts no., and M0000 Ø
4 Dimensions (in mm). Upgrade kit PASVE SF - Flange SF D0-0mm outer diameter Ø0 0 x 0 Ø Valve body LV O-ring Ø, x, NBR V0000 T00 T00 T00 V V000 T00 Upgrade kit, assembly M000 PASVE SF - Flange SF D0 APV-FN-0-0mm outer diameter, Ø, Ø Ø0, Ø0 0 x 0 Ø. Mounting of PASVE SC/SP Locking screw M Locking screw M Protection kit a PTFE gasket PTFE gasket Rubber gasket Rubber gasket a a PASVE SC. Drill a Ø0mm hole for the valve (type SC). Slacken locking grub screw. Unscrew the coupling part () from the body () right hand thread and remove all parts from coupling.. Weld the coupling part () taking care not to distort it - use small welding rod and multiple passes to minimise heating. re assemble the PASVE S valve assembly into the coupling as shown PASVE SP T-pipe Mounting of PASVE SH and ST Pull-out sleeve Spring Locking sleeve Retaining screw Mx DIN A T00 T00 T re tighten the assembly- right hand thread - by hand. Do not over tighten or use tools to tighten as this will damage the valve. PASVE SH and ST will be fixed with a clamp to the coupling. Protection kit, assembly M000. Tighten the locking screw
5 Special instructions for the safe use. Septum rubber replacing Please note: Pictures illustrate operational principles only, not accurate drawings.. Safe sampling Take the sample. Replace the rubber septum Turn the valve to the sample taking position Figure - Figure - Figure -, Pasve in sample taking position Pasve in the sample taking position Remove the sampling syringe from the valve Figure - Figure - Open the shut-off plug by turning it counterclockwise! Turn the valve to the maitenance positition Install the special nut V by turning it counterclockwise! -First screw the special nut V lightly in -When it reaches the rubber septum tighten the nut - turns Do not remove any other parts! Figure - Figure -0 Figure - Install the shut-off plug by turning it clockwise! Remove the special nut V by rotating it clockwise! Push the sampling syringe through the rubber septum. Figure - Figure - Turn the valve to the maintenance position Figure - Figure - Figure -
6 ..0. Changing of the gasket and the rubber seal. Reinstall the top part of the valve on the coupling part by turning it clockwise! Tighten it by hand, don't use any tools.. Open the locking screw.. Separate the top part of the valve from the coupling part by turning it counterclockwise!. Tighten the locking screw. Figure - Figure - Top parts of the valve Coupling part Figure - 0
M1 series 2 way ball valve with integrated Praher Labeling System
General: Material: PVC-U Seal material: EPDM / FPM Ball seating joint: PTFE Dimensions: DN10 DN50 d16 d63 d3/8 d2 Connection types: Solvent socket DIN / ASTM / JIS Solvent spigot DIN Threaded socket BSP
More informationSATRON VB Pressure Transmitter
SATRON VB pressure transmitter belongs to the series V transmitters. SATRON VB is userfriendly, through the ball valve mounted transmitter which is used for 04 kpa... 03 MPa ranges. The transmitter communicates
More informationDifferential Pressure Transmitter using two separate pressure sensors. On the measuring ranges 7,5:1-25:1: max.span
SATRON VDU differential pressure transmitter belongs to Vseries transmitters. SATRON VDU differential pressure transmitter is used from kpa to 3 MPa ranges (static pressure + measuring range). It is a
More informationDiesel Pile Hammer D30-32 Part # 66508
Diesel Pile Hammer D30-32 Part # 66508 2 Diesel Pile Hammer D30-32 Part # 66508 Pos Order No Pg Description Qty 66508 Diesel Pile Hammer D30-32 cmpl 1 1 108742 4 Cylinder Lower Part cmpl 1 2 60151 Inner
More informationInstallation and Setting-Up Instructions Spare Parts List
M, revision 3 Installation and Setting-Up Instructions Spare Parts List Contents: INSTALLATION. Mechanical installation. Electrical connections SETTING UP. Using the Hart 75 user interface. Setting up
More informationService instructions. CR, CRI, CRN 10, 15 and /60 Hz 1/3~
Service instructions CR, CRI, CRN 10, 15 and 20 50/60 Hz 1/~ 1. Type identification... 2 1.1 Nameplate... 2 1.2 Type key... 1. Code for shaft seal... 4 2. Tightening torques and lubricants... 5. Service
More informationInsertion Transducer On-line Install Instruction
LOGO Insertion Transducer On-line Install Instruction Shanghai Dynameters Co., Ltd www.dynameters.com Insertion Transducer Installation Manual Installation steps 1. Locate Installing point 2. Weld mounting
More information25000 Series Lo-T TM Butterfly Control Valve Instructions
November 2001 25000 Series Lo-T TM Butterfly Control Valve Instructions Instruction No. 25.1:IM PRELIMINARY STEPS Before installation, note the flow direction arrow on the valve body. The flow should enter
More informationDiesel Hammer Model D19-42 Part #
Diesel Hammer Model D19-42 Part # 120491 2 Diesel Pile Hammer Part # 120941 Pos Order No. Pg Description Qty 120941 Diesel Pile Hammer D19-42 (Bauer MNR:426514) 1 160198 4 Cylinder Lower Part cmpl 1 2
More informationGWR2 Installation guide: Guided Wave Radar
GWR2 Installation guide: Guided Wave Radar -1-4-wire TDR-Sensor with single rod or coaxial probe for continuous level measurement and point level detection in liquids, with analog and switching output.
More informationThis product is designed for a water supply pressure range of 20 psi (137kPa) minimum to 80psi (550 kpa) maximum.
We appreciate your commitment to Kohler quality. Please take a few minutes to review this manual before you start installation. If you encounter any installation or performance problems, please don t hesitate
More informationMagnetic level indicators made in Australia under licence to Weka AG of Switzerland.
ABN 24 080 175 293 PO Box 212 Caringbah NSW 1495 Sydney Australia ph: +61 (0)2 9542 8977 fx: +61 (0)2 9542 7978 www.controlcomponents.com.au Magnetic level indicators made in Australia under licence to
More informationMounting Accessories. Installation Guide. VIVOTEK SD83XXE Speed Dome
VIVOTEK SD83XXE Speed Dome Mounting Accessories AM-116/117 Pendant Pipe AM-118 Pendant Head AM-221 Gooseneck AM-231 Parapet Mount AM-519 Pendant Adaptor Installation Guide Corresponding part numbers: AM-116:
More informationinstallation instructions WC Frame 1180mm with Dual Flush Cistern
installation instructions WC Frame 1180mm with Dual Flush Cistern (C,D,E) K F/G N L M 12 13 14 16 1 2 11 A 5 6 Q O Y 3 C 10 E D B P,Z,AA R T V S 4 U 2 No. Part no. Description Quantity A WC Frame with
More informationDrilling machine Drilling machine for under pressure drilling Page Q 2/1 Motorised drilling machine Page Q 2/2
TOOLS Page Q 2 Drilling machine Drilling machine for under pressure drilling Page Q 2/1 Motorised drilling machine Page Q 2/2 Page Q 3 Changeable carbide drill (WHM) Page Q 3/1 Drilling machine Tonisco
More informationRG REPAIR GUIDELINE 10/23/2015. Repair Description: Tools Required: Step List: Approximate time: minutes
Repair Description: Replace BP54000/BP55000 with PA54000 for repairs Tools Required: ) # Philips head screwdriver or Drill ) Small, flat head screwdriver ) Dremel Tool or ¼ round file 4) Caulking Gun 5)
More informationSeries GWL - Radar Level Transmitter for Liquids
TM Series GWL - Radar Level Transmitter for Liquids Bulletin L-GWL Specifications - Installation and Operating Instructions 4-7/16 [112.63] Ø3-19/32 [90.96] 1-9/16 [39.42] 5-19/32 [142.07] 3-17/32 [89.95]
More informationinstallation instructions
installation instructions Easi-Plan WC Frame 820mm with Dual Flush Cistern ref: EPWC-05-1005 Easi-Plan WC Frame 980mm with Dual Flush Cistern ref: EPWC-05-1505 EASI-PLAN installation instructions Parts
More informationECT Applications. Features
ECT 847 Industrial Pressure Transmitter Swiss based Trafag is a leading international supplier of high quality sensors and monitoring instruments for measurement of and temperature. The economical transmitter
More informationAIR KIT 3. Heavy-Duty Public Bike Pump
Heavy-Duty Public Bike Pump The Air Kit 3 is designed for heavy-duty, repeated public use. The waterproof gauge and burly construction mean that this pump will continue to work long after others have failed.
More informationA Higher Level of Performance. Data Sheet. Series Pressure and Level Transmitters. For more information, please visit >
A Higher Level of Performance Data Sheet Series 000 Pressure and Level Transmitters For more information, please visit > www.hawkmeasure.com Series 000 000-SAN Cable with separate electronics Description
More informationASOLA - THETA ISTRUZIONI DI MONTAGGIO FITTING INSTRUCTIONS INSTRUCTIONS DE MONTAGE INSTRUCCIONES DE MONTAJE MONTAGEANLEITUNG. IMPBAT Rev.
ASOLA - THETA I F E D ISTRUZIONI DI MONTAGGIO FITTING INSTRUCTIONS INSTRUCTIONS DE MONTAGE INSTRUCCIONES DE MONTAJE MONTAGEANLEITUNG IMPBAT08-2 - Rev. 00 "THETA" FITTING INSTRUCTIONS SUB-FRAME Correct
More informationFisher 667 Diaphragm Actuators Size 80 and 100
Instruction Manual 667 Size 80 and 100 Actuators Fisher 667 Diaphragm Actuators Size 80 and 100 Contents Introduction... 1 Scope of Manual... 1 Description... 2 Specifications... 2 Maximum Pressure Limitations...
More informationH2-50 Hydrogen Generator Field Update
This field update is intended to provide extra protection in the event the H2 generation cell fractures or cracks. Please add the additional parts to your H2-50 as soon as possible. Please take a digital
More informationTechnical Data Measuring principle Thick-film-on-ceramic 25 C typ. ± 0.3 % FS typ. (± 0.5 % FS typ., ± 1 % FS typ.)
ECT 87 Industrial Pressure Transmitter Swiss based Trafag is a leading international supplier of high quality sensors and monitoring instruments for measurement of and temperature. The economic transmitter
More informationJARVIS. Model Brisket Scissor EQUIPMENT... TABLE OF
Model 423-17 Brisket Scissor EQUIPMENT SELECTION... Ordering No. TABLE OF CONTENTS... Page Model 423--17... 4037003 Air Filter / Regulator / Lubricator 3022003 Air Hose Assembly... 3059018 Balancer...
More informationRemarks: Before Installation, please read the instruction carefully.
60 cm antenna Z24A60T37301 Remarks: Before Installation, please read the instruction carefully. This instruction book is for the installation of 0.6m ultra-high performance microwave antenna. Installation,
More informationThe transducer component converts the measured signal and displays the actual value.
Digital inductive conductivity transmitter System Integration Provides low Total Cost of Ownership PEEK/PPA version for CIP applications TEACH IN and SIMULATION Function Approval PVDF Version PEEK Version
More information4" (DN 100) 5RET Tank Car Fire-Tite Bottom Unloading Valves. Installation, Maintenance and Operating Instructions
4" (DN 100) 5RET Tank Car Fire-Tite Bottom Unloading Valves Installation, Maintenance and Operating Instructions IMO-R14 11/2013 2 IMO-R14 Table of Contents 1 GENERAL....................................
More informationDigital inductive conductivity transmitter
Digital inductive conductivity transmitter Optimal solution for conductivity measurements in difficult fluids (polluted, dirty,...) PEEK/PPA version for CIP applications Large range of process connections
More informationInstallation Instructions
Installation Instructions For 4 foot / 1.2m Diameter Ultra-high Performance Antenna Model ADxxG-4-T2 Before Installation, please read the instructions carefully. This instruction guide covers the installation
More informationLU6X-130 Instructions and Parts List (including LU6X Basic) Operating Instructions
LORTONE LU6X-130 Item # 061-092 LU6X Basic Item # 061-090 LU6X-130 Instructions and Parts List (including LU6X Basic) Operating Instructions Introduction The LU6X is one the most versatile pieces of equipment
More informationMagnetic-inductive flow meter. PITe / UMF2. Technical Datasheet. Maintenance-free Nearly no pressure drop Robust design Easy installation and start-up
Magnetic-inductive flow meter Technical Datasheet PITe / UMF2 Maintenance-free Nearly no pressure drop Robust design Easy installation and start-up Subject to change without notice 1 Function An electrically
More informationinstallation instructions WC Frame 820mm with Dual Flush Cistern _INST
installation instructions WC Frame 820mm with Dual Flush Cistern 1 2014-0010-0820_INST J 8 9 E/F M 7 K L 1 2 6 5 P A U C D B Q 4 T 3 N O W S R 2 No. Part no. Description Quantity A WC Frame with Dual Flush
More informationDrilling machine for use on branch saddles fused. Instructions for assembly and use
Drilling machine for use on branch saddles fused Instructions for assembly and use DRILLING MACHINE FOR USE ON BRANCH SADDLES FUSED ON POLYETHYLENE PIPELINES FOR PRESSURE AND NON-PRESSURE USE Ø 90 1000
More informationMUELLER. Improved, Centurion Series, Modern Improved, and 107. Fire Hydrants. Inserting Extention Sections. Reliable Connections
insertion Instructions manual MUELLER Improved, Centurion Series, Modern Improved, and 107 table of contents PAGE Centurion Series Fire Hydrant Adding an Extention 2-3 Improved Fire Hydrant Inserting Extention
More informationWILLIS WALL-MOUNT FAUCET INSTALLATION
SKU(s): 924620 BEFORE YOU BEGIN We recommend consulting a professional if you are unfamiliar with installing bathroom fixtures and plumbing. Signature Hardware accepts no liability for any damage to the
More informationISSUE MODIF. ORDER NO. WEEK ISSUE MODIF. ORDER NO. WEEK ISSUE MODIF. ORDER NO. WEEK 01 SME SME SME
1. Summary The still pipe used with Rosemount 5900 LPG/LNG antenna is not supplied by RTR, but is to be manufactured by the customer according to the RTR drawing D9240041-910 or D7000001-466. Additional
More informationInstallation and Setting-Up Instructions Spare Parts List
M, revision 5..0 Installation and Setting-Up Instructions Spare Parts List Contents: INSTALLATION. Mechanical installation. Electrical connections SETTING UP. Using the 75 user interface. Setting up through
More informationInstallation and Setting-Up Instructions Spare Parts List
M, revision Installation and Setting-Up Instructions Spare Parts List Contents: INSTALLATION. Mechanical installation. Electrical connections SETTING UP. Applications/Liquid level measurement. Using the
More informationOTECO INC. MODEL ,000 PSI 4-1/16 PORT DM GATE VALVE MAINTENANCE MANUAL
Page 1 of 7 OTECO INC. MODEL 45 4 5,000 PSI 4-1/16 PORT DM GATE VALVE MAINTENANCE MANUAL Page 2 of 7 TABLE OF CONTENTS 1. Assembly Blowout 2. Repair Kit Contents & Technical Specifications 3. Disassembly
More informationDigital conductivity transmitter
Digital conductivity transmitter Compact version with integrated conductivity electrodes Remote version with seperated transmitter for short (15 ft.) or long (1500 ft.) distance Commissioning is easy due
More informationEN 1092 PN 10 EN 1092 PN 16 JIS B K ANSI B16.5 Class 150 ANSI B16.47 Class 150 BS 10 Table D
HG EN 1092 PN 10 EN 1092 PN 16 JIS 2238 10K ANSI 16.5 Class 150 ANSI 16.47 Class 150 S 10 Table D Stafsjö s knife gate valve HG is a bi-directional valve, particularly well suited for severe operating
More informationFBX1104P FBX1104 FBX1106P FBX1106
FBX1104P FBX1104 FBX1106P FBX1106 Second edition : September 2004 No. 040037 INTRODUCTION Thank you for your purchasing Kansai Special's FBX Series. Read and study this instruction manual carefully before
More information...thoroughly tried and tested!
...thoroughly tried and tested! Tapping and bushing with EWE tools www.ewe-armaturen.de Installation and operating instructions for EWE drilling units 1. Details of product 1.1. Application field EWE tapping
More informationThe Virgo/Libra Steam Engine
The Virgo/Libra Steam Engine Congratulations on becoming the owner of a Virgo or Libra Steam Engine. With careful use and maintenance it will give many years of satisfying performance. Contents 1) Notes
More informationTemperature Sensor with M12 hygienic
1 Product Information TFP-42, -52, -62, -162, -182 Temperature Sensor with M12 hygienic FOOD Application / Specified Usage Authorizations Temperature Measurement in pipes DN15...DN80 Temperature measurement
More informationRemarks: Before Installation, please read the instruction carefully.
30 cm antenna Z24A30T37301 Remarks: Before Installation, please read the instruction carefully. This instruction book is for the installation of 0.3m ultra-high performance microwave antenna. Installation,
More informationEngineering Data Single Reduction Parts List Item # Description Basic Single Reduction Unit 1. Gear Housing 2. Pipe Plug 3. Vent Plug 4. Splash Guard
Engineering Data Single Reduction Parts List Item # Description Basic Single Reduction Unit 1. Gear Housing 2. Pipe Plug 3. Vent Plug 4. Splash Guard 5. Input Cover 6. O-Ring 7. Hex Head Cap Screw 8. Input
More informationMUELLER. Improved, Centurion Series, Modern Improved, and 107. Fire Hydrants. Inserting Extension Sections. Reliable Connections
insertion Instructions manual MUELLER Improved, Centurion Series, Modern Improved, and 107 table of contents PAGE Centurion Series Fire Hydrant Adding an Extension 2-3 Improved Fire Hydrant Inserting Extension
More informationPSI COMPAKT SEALS AND WALL SLEEVES WITH FIXED/LOOSE FLANGE
PSI COMPAKT SEALS AND WALL SLEEVES WITH FIXED/LOOSE FLANGE IN GALVANIZED OR STAINLESS STEEL FOR BUILDINGS WITH OR WITHOUT SEALING SHEETS IN SPLIT VERSION FOR RETROFITTING WWW.PSI-PRODUCTS.COM 37 GENERAL
More informationGH BETTIS SERVICE INSTRUCTIONS DISASSEMBLY & REASSEMBLY FOR MODEL F10207 DOUBLE ACTING HYDRAULIC ACTUATOR
GH BETTIS SERVICE INSTRUCTIONS DISASSEMBLY & REASSEMBLY FOR MODEL F10207 DOUBLE ACTING HYDRAULIC ACTUATOR PART NUMBER: 074960 REVISION: "A" RELEASE DATE: NOVEMBER, 1991 Page 1 of 6 1.0 INTRODUCTION 1.1
More informationMODEL D DIESEL PILE HAMMER
AMERICAN PILEDRIVING EQUIPMENT, INC. MODEL D125-42 DIESEL PILE HAMMER SPARE PARTS BOOK Corporate Office 7032 S. 196th Street Kent, WA, USA 98032 Tel: 1-800-248-8498 Tel: 1-253-872-0141 Fax: 1-253-872-8710
More informationSA seal Sanitary diaphragm seal type
SA seal Sanitary diaphragm seal type Design description Badotherm sanitary seals are designed for pressure, level and flow measurements in food & beverage and pharmaceutical industries where the formation
More informationHigh Speed Air Turbine Handpiece
OPERATION MANUAL High Speed Air Turbine Handpiece Please read this Operation Manual carefully before use and file for future reference. Handpiece should not be used with friction grip burs exceeding 18.5
More informationCAT GB. Quick-release couplings and accessories for Air Conditioning & Refrigeration. UNI EN ISO 9001 Cert. n 2905 ISO/TS 16949
CAT. 0118-GB Quick-release couplings and accessories for Air Conditioning & Refrigeration UNI EN ISO 9001 Cert. n 905 ISO/TS 16949 Quick-release couplings and accessories for Air Conditioning & Refrigeration
More informationVersion: 1.0 Revised: 6/8/2011. CBU Assembly Instructions Manual
CBU Assembly Instructions Manual Contents 1 General... 3 2 Package... 4 2.1 Packing order... 4 2.2 Unpacking... 5 3 Assembly of the body... 6 3.1 General... 6 3.2 Mounting base drilling chart... 8 3.3
More informationHARDINGE Installation booklet For:
HARDINGE Installation booklet For: L Flange Nose Dead-Length Collet Adaptation Chucks Draw Collet Read the enclosed instructions and recommendations before any installations WARRANTY & RETURN PROCEDURES
More informationMaintenance Information
16601023 Edition 2 January 2014 Air Impact Wrench 2705P1 Maintenance Information Save These Instructions Product Safety Information WARNING Failure to observe the following warnings, and to avoid these
More informationMKS. MKS Series MKS 40 MKS 45 MKS 50 MKS 55 MKS 60 MKS 65. Repair Manual
MKS Series MKS 40 MKS 45 MKS 50 MKS 55 MKS 60 MKS 65 Repair Manual INDEX. INTRODUCTION 3 2. REPAIR INSTRUCTIONS 3 2. Crank Mechanism Repair...3 2.. Crank Mechanism Disassembly...4 2..2 Crank Mechanism
More informationLevel transmitters Series LTDR TDR guided radar level transmitter for liquids and solids
Level transmitters Series LTDR TDR guided radar level transmitter for liquids and solids Level measurement independent of changing process conditions (density, conductivity, temperature, pressure, ) Innovative
More informationMALEKO WALL-MOUNT FAUCET INSTALLATION
SKU(s): 934146 BEFORE YOU BEGIN We recommend consulting a professional if you are unfamiliar with installing bathroom fixtures and plumbing. Signature Hardware accepts no liability for any damage to the
More informationSeries B Medical Gas Service Outlet Upgrade Kits
Installation Instructions Series B Medical Gas Service Outlet Upgrade Kits For additional information concerning operation of Puritan Bennett Series B Quick-Connect Outlet Valves, refer to Operating Instructions
More informationPORTABLE PULL TESTER
2425 West Vineyard Avenue, Escondido, California 92029-222 Phone: (800) 284-4460 Fax: (760) 746-4295 PORTABLE CABLE TERMINAL PULL TESTER AT520CT (Revised July 2003) AT520CT Portable Cable Terminal Pull
More informationRosemount 5408 and 5408:SIS Level Transmitters
Quick Start Guide 00825-0100-4408, Rev AD March 2018 Rosemount 5408 and 5408:SIS Level Transmitters Cone Antenna Quick Start Guide March 2018 1 About this guide This Quick Start Guide provides basic guidelines
More informationFM125 & FM126 Service Guide
FM125 & FM126 Service Guide FM125-0022 & FM125-0024 Repair Kit 1 2 3 4 #1-1 Pc. FM125-5012 Ball Carrier Installation Tool (FM125-0022 Only) #2-2 Pcs. P5-287-R0 O-Ring #3-2 Pcs. P5-067-R2 O-Ring #4-1 Pc.
More informationFlow Measurement SITRANS F M
Overview Mode of operation The flow measuring principle is based on Faraday s law of electromagnetic induction according to which the sensor converts the flow into an electrical voltage proportional to
More informationBETTIS SERVICE INSTRUCTIONS FOR MODELS G01 THROUGH G10 SERIES HYDRAULIC SPRING RETURN ACTUATORS WITH M11 HYDRAULIC OVERRIDE
ENGLISH LANUAGE BETTIS SERVICE INSTRUCTIONS FOR MODELS G01 THROUGH G10 SERIES HYDRAULIC SPRING RETURN ACTUATORS WITH M11 HYDRAULIC OVERRIDE PART NUMBER: 127072E REVISION: A DATE: December 2001 Page 1 of
More informationw w w. h d o n l i n e s h o p. d e TIMKEN BEARING CONVERSION TOOL GENERAL INSTALLATION -J04672 REV Kit Number Models
-J067 REV. 008-07- GENERAL Kit Number 8-08 Models TIMKEN BEARING CONVERSION TOOL For model fitment information, see the P&A Retail Catalog or the Parts and Accessories section of www.harley-davidson.com
More information400 SERIES GRINDER PUMPS 41502, 42202,43302, AND MODELS
Section: MOYNO 500 PUMPS Page: 1 of 6 Date: March 1, 1998 SERVICE MANUAL MOYNO 500 PUMPS 400 SERIES GRINDER PUMPS 41502, 42202,43302, AND 44402 MODELS DESIGN FEATURES Housing: Cast iron Pump Rotor: Chrome
More informationB-Too Drilling and Tapping Machine Instruction and Maintenance Manual
B-Too Drilling and Tapping Machine Instruction and Maintenance Manual Thank you for your purchase of the B-Too Drilling and Tapping Machine. Please read and understand this short operation manual. Our
More information2-jaw parallel self-centering pneumatic gripper (series GM)
GM -jaw parallel self-centering pneumatic gripper (series GM) Double acting. The rugged construction lends itself to heavy duty applications for a trouble free long life without maintenance. Wide choice
More informationService Parts List AA4V90
Service Parts List AA4V90 Series 1 06.96 Ordering of AA4V Parts For Rexroth to supply the correct parts for your unit, please include all of the following information with your parts order. TYPE CODE TYPE
More information.1 Materials and installation for steel piping, valves and fittings for hydronic systems in building services piping..2 Related Sections.
Issued 2006/08/01 Section 15183 Hydronic Systems: Steel Page 1 of 6 PART 1 GENERAL 1.1 SUMMARY.1 Section Includes..1 Materials and installation for steel piping, valves and fittings for hydronic systems
More informationPage 1. SureMotion Quick-Start Guide: LARSACC_QS 1st Edition - Revision A 03/15/16. Standard Steel Bolt/Screw Torque Specifications
R K C T I Repair Kit Product Compatibility Repair Kit # Linear Actuator Assembly # LARSACC-013 LARSACC-014 LARSD2-08T12BP2C (12-in travel) LARSD2-08T24BP2C (24-in travel) C P I R K 1 ea Ball Screw with
More informationInstallation Instructions
MOUNT TUB SYSTEMS HAMPTON TRIM KIT T980.702 Installation Instructions T980.702 T980.712 T980.722 T980.732 Thank you for selecting American-Standard...the benchmark of fine quality for over 100 years. To
More informationPharma-Temperature Sensor M12 hygienic
SENSORS FOR FOOD AND BIOPHARMA. Product Information TFP-42P, -52P, -62P, -162P, -182P PHARMA Pharma-Temperature Sensor M12 hygienic Application/Specified usage Temperature measurement in pipes DN15...DN80
More informationDigital flow ELEMENT transmitter for continuous flow measurement
ELEMENT Transmitter Digital flow ELEMENT transmitter for continuous flow measurement Type can be combined with... PN10, DN15 to DN400 fluidic process connection Programmable outputs : one or two transistor
More informationLimit switch set BOA-H DN PN 16/25 Material variant EN-GJS LT
Assembly instructions 0570.812/04-EN Limit switch set BOA-H DN 15-150 PN 16/25 Material variant EN-GJS-400-18-LT Fig. 1 Exploded view of limit switch set... 2 Fig. 2 Parts list for limit switch set...
More informationROTUNDA WALL-MOUNT FAUCET INSTALLATION
SKU(s): 919045 BEFORE YOU BEGIN We recommend consulting a professional if you are unfamiliar with installing bathroom fixtures and plumbing. Signature Hardware accepts no liability for any damage to the
More informationTemperature Sensor with M12 hygienic
SENSORS FOR AND BIOPHARMA. Product Information TFP-42, -52, -62, -162, -182 Temperature Sensor with M12 hygienic Application / Specified Usage Temperature Measurement in pipes DN15...DN80 Temperature measurement
More informationLPK1550 Hydraulic Crimping Tool 15-ton
SERVICE MANUAL LPK1550 Hydraulic Crimping Tool 15-ton Serial Code FYF Read and understand all of the instructions and safety information in this manual before operating or servicing this tool. Register
More information2-jaw self centering rocking pneumatic gripper (series GW)
2-jaw self centering rocking pneumatic gripper (series ) Double acting. Long life and reliability, maintenance free. Various options for fastening. Optional proximity magnetic sensors. Spring closed (-NC)
More informationINDUSTRIAL PRESSURE TRANSMITTER
ECT 87 INDUSTRIAL PRESSURE TRANSMITTER Swiss based Trafag is a leading international supplier of high quality sensors and monitoring instruments for measurement of and temperature. The economic transmitter
More informationMUELLER GAS. DH-5/EH-5 Drilling. Reliable Connections. DH-5 Drilling Machine General Information 2. EH-5 Drilling Machine General Information 3
operating Instructions manual MUELLER GAS TAble of contents PAGE DH-5 Drilling Machine General Information 2 DH-5/EH-5 Drilling EH-5 Drilling Machine General Information 3 Operating Instructions 4-5 DH-5
More information2-JAW SELF-CENTERING RADIAL PNEUMATIC GRIPPER (SERIES PS)
PS 2-JAW SELF-CENTERING RADIAL PNEUMATIC GRIPPER (SERIES PS) Double-acting radial motion. The gripping force is constant throughout the entire stroke (from 0 to 90, both opening and closing). Lightweight:
More informationIn-Line Resistance Thermometers Model TR25
Electrical Temperature Measurement In-Line Resistance Thermometers Model TR25 WIKA Data Sheet TE 60.25 Applications Food and beverage industry, dairies, drink dispensers and bottling plants, breweries
More informationSERVICE MANUAL CLINTON FEED OFF THE ARM CHAIN CUTTER WITH EXTERNAL AIR DRIVE MODEL 2115FOTA-V FOR UNION SPECIAL 35800, & YAMATO FD-62 ML2115-7A
ML2115-7A CLINTON FEED OFF THE ARM CHAIN CUTTER WITH EXTERNAL AIR DRIVE MODEL 2115FOTA-V FOR UNION SPECIAL 35800, 36200 & YAMATO FD-62 SERVICE MANUAL 40-0164-01 ML2115-8E I. GENERAL INFORMATION A. The
More informationZero Point Clamping System. ZERO lock BALL lock
Zero Point Clamping System ZERO lock BALL lock kap3 kap 263 Technical information regarding ZERO lock Zero Point Clamping System Application The modularly designed, flexible ZERO lock Zero-Point Clamping
More informationRepair Manual MK40A-MK45A-MK50A MK55A-MK60A-MK65A. Ref Rev.C General Pump is a Member of The Interpump Group
MK Repair Manual MK40A-MK45A-MK50A MK55A-MK60A-MK65A General Pump is a Member of The Interpump Group 8 INDEX 1. INTRODUCTION..................................................Page 3 2. REPAIR INSTRUCTIONS...........................................Page
More informationcaroma marc newson wall basin mixer
caroma marc newson wall basin mixer water efficient tapware (nominal flow rate = 5 L/min) PLUMBERS INSTALLATION INSTRUCTIONS IS1213A(07/12) Important Information Brazed connections should NOT be made directly
More informationSGP-S - Compact Parallel Gripper
11: Double acting Patented backlash adjusting system. High performance in a compact size. The rugged construction lends itself to heavy-duty applications for a trouble-free long life without maintenance.
More informationthoroughly tried and tested! EWE Tapping Valves A single system for all types of pipes
thoroughly tried and tested! EWE Tapping Valves A single system for all types of pipes www.ewe-armaturen.de EWE Tapping Fittings high-quality products from Germany EWE tapping fittings are the product
More informationOperating, Servicing, and Safety Manual Model # 100 Standard Hydraulic Tubing Notcher Model #100-U Heavy Duty Hydraulic Tubing Notcher
Operating, Servicing, and Safety Manual Model # 100 Standard Hydraulic Tubing Notcher Model #100-U Heavy Duty Hydraulic Tubing Notcher Model # 100 Standard Model #100-U Heavy Duty CAUTION: Read and Understand
More informationROCK DRILLS Tabor Place, Santa Fe Springs, California, CA 90670, U.S.A.
S Website: www.apt-tools.com e-mail: info@apt-tools.com TDS-1027 Rev A S TOOL MAINTENANCE & REPAIR INFORMATION FIELD OPERATION: Before use: 1. Fill the reservoir with air tool oil or 10W equivalent for
More information3 Emergency Breakaway Coupling
SM64227 July 2008 Applicable addition manuals: N/A Aerospace Group Conveyance Systems Division Carter Ground Fueling Maintenance & Repair Manual 3 Emergency Breakaway Coupling Model 64227 Table of Contents
More informationAccessories for sensors
Accessories for sensors Mounting and installation Adapters for pressure sensors: Hex AF width 27 ZBM 01 Adapter female thread G1/4 male thread G1/2 B, DIN EN 837-1 Part no.: 257276 Flat seal ring Cu 6.2x17.5x2.0
More informationOPTISENS PH ph sensor. Technical Datasheet
Technical Datasheet ph sensor High quality and precise glass sensor for usage in water and waste water analysis Special sensor design for harsh applications Low maintenance costs and a long life cycle
More informationTWIN ROD CYLINDERS 6 CONTENTS
CAD drawing data catalog is available. ACTUATORS GENERAL CATALOG TWIN ROD CYLINDERS6 CONTENTS TWIN ROD CYLINDERS 6 Features 745 Specifications/Order Codes 747 Inner Construction and Major Parts 748 Dimensions
More informationTemperature Sensor with G1/2" hygienic
SENSORS FOR FOOD AND BIOPHARMA. Product Information TFP-41, -44, -51, -54, -61, -161, -164, -181, -184 FOOD Temperature Sensor with G1/2" hygienic Application/Specified usage Temperature Measurement in
More information