BROCHURE COMPANY PRODUCTS AND SERVICES

Size: px
Start display at page:

Download "BROCHURE COMPANY PRODUCTS AND SERVICES"

Transcription

1

2 BROCHURE COMPANY PRODUCTS AND SERVICES Manufacture and supply of NOVOTEXI 440 concealed-fix steel roof sheeting Manufacture and supply of rainwater goods and roofing accessories Manufacture Purpose made rainwater goods Manufacture Flashings in 6m lengths, Louvre vents and copings CNC Precision sheet metal punching, bending and Fabrication (Slope vents etc.) On site and factory manufactured Bull-nosing and Curving Technical services Flashing Centre is a sister company to Arona Roofing and has manufactured roofing accessories and rainwater goods for 38 years. Concealed-fix roofing profile (NOVOTEXI 440) Arona Roofing (Pty) Ltd. Developed a concealed-fix roofing profile called NOVOTEXI 440 (Latin for New Cover 440mm effective cover width) to accommodate high winds as a result of greenhouse gases and global warming. As our planet becomes more and more exposed to the effects of greenhouse gases so global warming effects are starting to cause catastrophic weather conditions that in past years had remote occurrences of one in 50-year cycles. In recent years it is not unusual to see these harsh weather occurrences happening 3 times in a single year. As a result of these occurrences determining the terrain categories are becoming more and more crucial. The Structural Engineer is the key to ensure that the roof and the roof structure can handle the wind pressures. The down time cost as a result of a storm is not an option! Thus performance of roof sheeting systems need to be verified by Structural Engineers at the planning stage. All manufacturers of roofing products should be tested and verified to ensure those systems can accommodate the wind pressures required in the design of the structure. To ensure these tests are ligitimate an independent third party authority must certify the test results e.g.: CSIR or SABS etc. Patent Number: 2004/5204 The roofing Profile covers an effective 440mm and is generally roll formed on site mostly from G550 MPa high tensile steel to any practical length that is manageable by the roofing contractor and as low as 2 degrees pitch with no end lapping required. The center rib is designed to move freely to allow the profile to absorb wind gusts. Due to the nature of the rotational mechanism the male and female only start to inter-lock at wind pressures of around 1.2kN/m 2. The center rib may deflect as much as 100mm before wind load starts exerting pressures on the cleats. The unique patented rotational inter-locking mechanism is what makes this concealed-fix roofing system vastly different to other concealed-fix roofing systems available in the South African market: Once inter-locked the roof sheet is able to expand and contract freely and cannot unclip between the purlin supports through foot traffic. All residual moisture between the roof sheet and the insulation layer can still evaporate through the inter-locking mechanism. The roof sheeting has been designed to accommodate thick composite insulation and various types of insulation board. When insulation packs exceed 70mm thick we recommend this be inserted between the purlins with a t-section or top hat section. FIG 1:Deflection under negative FIG 2:Rotational Mechanism load Capacity: Arona Roofing (Pty) Ltd. Manufacture and Patent their own roll forming machines and at present have 4 mobile rolling mills. We have a factory in Paarden Eiland in Cape Town, which services the Peninsula and East coast regions, and a Factory in Pretoria that services the rest of the country. In late 2011 early 2012 we will have the capacity to service the southern and central African Markets. The rolling mills are light and compact and can be containerized for shipping or trucking to far reaching destinations. FIG 1:Roll forming on site 1

3 BROCHURE Quality of materials used to manufacture NOVOTEXI 440 roof sheeting: Description Gauge TCT Thickness Tensile Strength MPa Coating Mass Mass per Linear M Mass per m 2 ZINCALUME steel 0.47mm G550 AZ150 / AZ kg 4.84kg Clean COLORBOND steel 0.47mm G550 AZ kg 4.84kg ZINCALUME steel Ultra 0.47mm G550 AZ kg 4.84kg ZINCALUME steel 0.53mm G550 AZ150 / AZ kg 5.50kg Clean COLORBOND steel 0.53mm G550 AZ kg 5.50kg Clean COLORBOND Ultra 0.53mm G550 AZ kg 5.50kg ZINCALUME steel 0.80mm G550 AZ150 / AZ kg 8.25kg Galv/Chromadek 0.50mm ISQ550 Z275 / Z kg 5.52kg Please see the various literatures available from the suppliers to choose the Colors and Finishes. Material Warranties must be applied for prior to starting the project. NB: The lifespan of the roofing material is determined by the coating mass applied eg: AZ150 vs. AZ200. Various web sites: chromadek@arcelormittal.com, Recommended spacings of Purlin supports: It is crucial for the Structural Engineer to determine the effective purlin spacing s by using the design loads for each fixing cleat system: Clip Size Serviceability load Ultimate Load 40mm x 1.05mm G kN/m 2 Note kN/m 2 Note 1 60mm x 1.05mm G kN/m 2 Note kN/m 2 Note 1 80mm x 1.05mm G kN/m 2 Note kN/m 2 Note 2 80mm x 1.50mm G kN/m 2 Note kN/m 2 Note 2 1. This is an estimated negative load 2. This is tested and verified The Structural Engineer based on the above values will determine the end spans and intermediate spans based on the high-pressure zones. He will also indicate what cleats will be required where. Various configurations e.g.: putting two 60mm cleats side by side can improve the negative load capacity substantially. If in doubt please consult the manufacturer for further assistance. A detailed CSIR load test report is available on request. 0,50mm & 0,47mm 0,53mm Recommended side cladding 0,50mm & 0,47mm 0,53mm OVERHANG TBA: To be advised and confirmed by the Structural Engineer Recommended roof spans ROOFS Single End Internal Unstiffened Stiffened TBA TBA TBA TBA TBA TBA Single End Internal Overhang Wind loading performance The wind resistance of NOVOTEXI 440 concealedfix roofing system underwent a comprehensive testing program overseen and witnessed by CSIR s structural expert on wind loadings. (A detailed report on this programme, its testing methodology and results is available on request.) Because of the unique wind loading performance of Novotexi 440 (involving active rotational mechanism and the deflection of the centre rib), SANS testing requirements were used as a guideline. The system was able to sustain substantial magnitude negative loads and therefore suitable for the application in high pressure uplift zones derived in the design process. 2

4 Installation Procedure for NOVOTEXI 440 Step 1 Prior to starting the installation we assume that the insulation layer is already installed in place over the purlins. The purpose of the Starter bar is when installing the first sheet from a gable end that no stitching screws are used to hold this sheet in place, thus the starter bar holds down the first female lip of the first roof sheet only avoiding any perforation. Should the slope have multiple purlin spacing s it is possible to install 3m lengths at intermittent intervals. This portion is closed up with a barge flashing once the side cladding is installed. The starter bar is manufactured from either Galvanized or Zincalume material and is fixed in place with wafer head self-drilling screws. As illustrated the first sheet is hooked over the starter bar to start the installation process. The starter bar also allows the first roof sheet to expand and contract freely. Step 2 Once the first roof sheet is laid flat and installed in place square to the gable, end the fixing cleat must be clipped over the male lip and fixed into the purlin with wafer head self drilling screws. Care should be taken that the fixing cleat is square to the purlin surface. BROCHURE FIG 1:Roof sheet hooked over stater bar FIG 2:Starter bar fitted over first Purlins Step 3 Taking the next roof sheet and holding this sheet at around 90 degrees to the first sheet inter-lock the female over the male and lay flat. Keep in mind there is usually very little tolerance +/-2mm between the male and female at 90 degrees. Once the sheets are inter-locked and laid flat prior to fixing the next cleats in place an easy check is to feel the lap as illustrated to make sure the sheets are installed properly, simply by pulling up the sheets will ensure the lap is closed. Usually the process of pulling up the sheet feeling the lap and securing the next fixing cleat is done simultaneously in one operation. Final Step All roofing contractors are to take special note of the following because Novotexi 440 is cut to length by friction saw during the on site rolling process this causes the female lip to flare for about 120mm from the cut-off! The sheet must be closed as illustrated. Great care must be taken to make sure this operation is adhered to by all installation teams. After a section is installed and before the installation teams leave the site for that day the ends must be closed as part of work in progress, even if the ends run into gutters that need to be trimmed off closing is essential. If the structure has a single span after a gutter and short sheets are used where the overhang is 250mm after the last purlin these ends must be closed with the closing tools as there is very little material to support the cleat. Bending down and bending up of roof sheeting on the eaves and ridges is seen as standard practice on all kinds of roofing systems and the tooling Manufactured specifically for Novotexi 440 is supplied by Arona Roofing (Pty)Ltd. Arona Roofing (Pty) Ltd supply NOVOTEXI 440 to an approved roofing contractor base in the various provinces that supply various warranties after installation. With new contractors not familiar with the installation of NOVOTEXI 440 training is essential and is done under supervision of Arona Roofing on request. Kicking the roof sheets to get them to engage occurs when the purlin plains are not within the required tolerance, this practice will not effect the performance of the roof sheets however contractors are to wear soft soled shoes when this method is applied. Novotexi 440 is designed so that there FIG 1:Fixing cleat over male lip FIG 2:Align over Purlin FIG 1:Hold Sheet at 90º to engage FIG 3:Fasten Cleat to Purlin is a minimum clearance of 2mm between male and female at around 90 degrees. FIG 1:Closing is critical FIG 2:Make sure sheet is pulled up tight FIG 2:Make sure sheet is closed on the ends 3

5 Fixing Cleats 60mm & 80mm Fixing cleats BROCHURE The fixing cleats are the heart of the system and determine the various negative wind load capacities. (Please remember the thickness of the roof sheeting in NOVOTEXI 440 does not determine negative wind load capacity) Thickness of roofing material becomes critical when positive point loads are of concern e.g.: When secondary trades are expected to walk on roofs after installation with additional point loads e.g.; air conditioner units or extractor fans are carried onto the roof. It is standard practice to walk in the pans or over the purlins when walking on steel roofs. 40mm x 1.05mm G550 AZ150 Truecore Cleat 60mm x 1.05mm G550 AZ150 Truecore Cleat 80mm x 1.05mm G550 AZ150 Truecore Cleat Recommended Fixings: We strongly recommend that proper attention is given to the selection of fixings used to fasten the cleats in place and which is used to fix the flashings etc.; To fix the cleats into steel a #10 x 22mm Wafer Head self drilling screw SANS1273 class 3 coated must be used and for timber #10 x 45mm Wafer Head type 17 point SANS1273 class 3 coated to be used. The material warranties may become void if the incorrect fixings are used. (Especially on Flashings) Please refer to Kare Industries for further information (2 Pre punched hole centre s 20mm apart) (4 Pre punched hole centre s 20mm & 50mm apart) (4 Pre punched hole centre s 20mm & 50mm apart) 80mm x 1.50mm G230 AZ150 Zincalume Cleat (4 Pre punched hole centre s 20mm & 50mm apart) N.B. Also note that when specifying a 80mm or 100mm fixing cleats it is important for the Structural Engineer to specify the appropriate lip-channels or purlin to accommodate fixing the cleat, e.g.: 80mm cleat would require a 60mm or 75mm lip-channel. Various Tooling and equipment supplied by Arona Roofing FIG 1:#10 Wafer Head x 22mm Bending Tool Closing Tool Seaming Machine These tools may either be rented or purchased from Arona Roofing Bull nosing, natural Curving and Cranking Novotexi 440 roofing for bull-nosed and curved sheeting is rolled with an open female lip. We roll the sheet in this state to allow the roofing contractor to install the sheets without tilting the roof sheets at 90 degrees, thus the sheets are installed horizontally. Once the sheet is inter-locked the castellated portion of the bull nose is aligned and closed with the closing tool. On the slope of the sheets every meter is closed with the closing tool as a temporary measure. After the roof is installed the seaming machine is run along the roof sheet to seam up the sheet. Roof structures that have a radius larger than 38m can be supplied without any castellation and the roll forming mill will roll a natural curve during site rolling. With curved structures less than 38m a crank every meter or so has to be cranked to achieve the radius. Closing the Bull nose using the closing tool. Prior to seaming close the sheet every meter or so. Trapezium Stiffener This was designed to create a walkway on roofs where there are secondary trades and maintenance crews that carry heavy loads exceeding the allowable point loads on the centre rib. This member is installed under each roof sheet during the installation process between two purlins. After installation the walkway is demarcated on top of the roof sheeting to indicate the safe walking areas. Splicing plate Trapezium stifner intalled under centre rib 4

6 Insulation board brackets: These brackets are available in various sizes and are supplied to maintain the spacing s between the roof sheeting cleats and the board. BROCHURE Solar panel brackets: This bracket was recently developed to secure solar panels onto the Novotexi 440 roof sheets without causing any damage or perforation. This bracket creates a base to fit various kinds of supporting structures on top of the roofing system without hindering the expansion and contraction of the roofing system. Available on request. Closures, polyclosures, bending pans and flashing brackets: Serrated closures are used under the flashings and are supplied in narrow or broad flute. If closures are used it is common practice to fix the closure into the flute of the roof sheeting and then fix the head-wall flashing into the closure and not into the roof sheet. Using this method water cannot leak into the roof because the perforation is concealed by the flashing. Poly closures are used in conjunction with the closure as illustrated and are supplied in a set of male and female. Bending up and down of the pans is standard practice when installing low pitched NOVOTEXI 440 and is critical to stop water running up the underside of the roof sheeting especially on the eaves ends. Flashing brackets are supplied if no closures are used to fix the flashings without perforating the sheets. Serated Closure Broad Flute Serated Closure Narrow Flute FIG1:Poly Closure with flashing bracket FIG2:Pan bending up ridge FIG3:Pan bending down eaves FIG4:Pan bending tool Contact us at: Pretoria: Tel No: l Fax: l aronaroofing@vodamail.co.za Website: l Address: 26 Eland Street, Koedoespoort 0186 Cape Town: Unit A No 9 Bridgewater Street, Paarden Eiland udo@aronaroofing.co.za l Tel No: l Fax:

Global Roofing Solutions Klip-Tite

Global Roofing Solutions Klip-Tite GRS Klip-Tite Global Roofing Solutions Klip-Tite Talk to us, THE SMART ROOF PEOPLE Visit www.globalroofs.co.za or email info@globalroofs.co.za GRS Klip-Tite Typical specification Materials The roofing

More information

Global Roofing Solutions Klip-Tite

Global Roofing Solutions Klip-Tite GRS Klip-Tite Global Roofing Solutions Klip-Tite www.globalroofs.co.za marketing@globalroofs.co.za GRS Klip-Tite GRS Klip-Tite 09/18 Typical Specification Materials The roofing shall be Klip-Tite profile,

More information

Talk to us, THE SMART ROOF PEOPLE Visit or Global Roofing Solutions Brownbuilt

Talk to us, THE SMART ROOF PEOPLE Visit   or  Global Roofing Solutions Brownbuilt Talk to us, THE SMART ROOF PEOPLE Visit www.globalroofs.co.za or email info@globalroofs.co.za Global Roofing Solutions Brownbuilt Typical specification Materials The roofing / side cladding shall be Brownbuilt

More information

Global Roofing Solutions Klip-Lok 700

Global Roofing Solutions Klip-Lok 700 GRS Klip-Lok 700 Global Roofing Solutions Klip-Lok 700 www.globalroofs.co.za marketing@globalroofs.co.za GRS Klip-Lok 700 GRS Klip-Lok 700 09/18 Typical Specification Materials The roofing shall be Klip-Lok

More information

Global Roofing Solutions Brownbuilt

Global Roofing Solutions Brownbuilt GRS Brownbuilt Global Roofing Solutions Brownbuilt www.globalroofs.co.za marketing@globalroofs.co.za GRS Brownbuilt GRS Brownbuilt 09/18 Typical Specification Materials The roofing / side cladding shall

More information

HILAND TRAY FORM AND FUNCTION MATERIAL SPECIFICATIONS DESIGN GUIDE ROOFING I WALLING

HILAND TRAY FORM AND FUNCTION MATERIAL SPECIFICATIONS DESIGN GUIDE ROOFING I WALLING HILAND TRAY ROOFING I WALLING DESIGN GUIDE FORM AND FUNCTION Hiland Tray is a modern 455mm wide tray roofing and walling system, roll formed onsite with a mobile roll forming facility in long single lengths

More information

DESIGN GUIDE Topdek 7 00

DESIGN GUIDE Topdek 7 00 Topdek 700 DESIGN GUIDE Innovative, stylish, strong and flexible, Topdek 700 is an exceptional cladding. FORM AND FUNCTION Utilising an ingenious concealed clip, Topdek 700 benefits from a strong, clean

More information

TRIM-KLIP INNOVATIVE END/EXPANSION JOINT SOLUTION FOR LYSAGHT TRIMDEK

TRIM-KLIP INNOVATIVE END/EXPANSION JOINT SOLUTION FOR LYSAGHT TRIMDEK TRIM-KLIP INNOVATIVE END/EXPANSION JOINT SOLUTION FOR LYSAGHT TRIMDEK LYSAGHT TRIM-KLIP The new TRIM-KLIP system provides installers with a quick and easy end joint/expansion joint solution between overlapping

More information

Tuff-Rib Install Guide

Tuff-Rib Install Guide Install Guide bestbuymetalroof.com Page 2 of 27 Page 3 of 27 1. Page 4 2. a. Installation Guide b. Panel Squaring Pages 5, 6 Pages 7, 8 3. Pages 9, 10 4. a. Fascia (optional) b. Eave / 1.5x3.5 Angle c.

More information

Table of Contents. Notes to Designer/User Map of Typical Roof Conditions Fastener Placement Fastener Selection...

Table of Contents. Notes to Designer/User Map of Typical Roof Conditions Fastener Placement Fastener Selection... Table of Contents Section Page Notes to Designer/User... 2-3 Map of Typical Roof Conditions... 4 Fastener Placement... 5 Fastener Selection... 6 Ridge/Hip Flashing... 7 Valley Flashing... 8 Eave Flashings...

More information

Sheet Steel Facts. Most common head design for self-drilling, self-tapping screws.

Sheet Steel Facts. Most common head design for self-drilling, self-tapping screws. Sheet Steel Facts Fastener Guide for Sheet Steel Building Products August, 2003 Fastener Materials Fasteners are manufactured from several materials and coatings. For the purpose of this fact sheet, the

More information

installation guide Villa

installation guide Villa installation guide Villa Table of Contents Introduction............................. 2 Safety................................... 2 Tools.................................... 2 Codes & Requirements....................

More information

Global Roofing Solutions Klip-Lok 406 Aluminium

Global Roofing Solutions Klip-Lok 406 Aluminium GRS Klip-Lok 406 Global Roofing Solutions Klip-Lok 406 Aluminium www.globalroofs.co.za marketing@globalroofs.co.za GRS Klip-Lok 406 GRS Klip-Lok 406 Alum. 09/18 Typical Specification Materials The roofing

More information

LONGLINE 305 WA design and installation guide western australia

LONGLINE 305 WA design and installation guide western australia LONGLINE 305 WA design and installation guide western australia 1 longline 305 WA Lysaght Longline 305 WA Steel roof cladding with long, clean lines longline 305 WA is a concealed fixed roof cladding with

More information

Lysaght Longline 305. Concealed-fixed cladding with long, clean lines

Lysaght Longline 305. Concealed-fixed cladding with long, clean lines Lysaght Longline 305 Concealed-fixed cladding with long, clean lines Strong, durable, versatile cladding with bold ribs and smooth pans Can be installed with roof pitch as low as 1º (1 in 50) Available

More information

Klip-Lok 406 Aluminium

Klip-Lok 406 Aluminium Klip-Lok 406 Alumin GRS Klip-Lok 406 Global Roofing Solutions TM Klip-Lok 406 Aluminium Talk to THE SMART ROOF PEOPLE Visit www.globalroofs.co.za or email info@globalroofs.co.za GRS Klip-Lok 406 GRS Klip-Lok

More information

ASSEMBLY INSTRUCTIONS GG77. BASE SIZE: 2.190m x 2.020m

ASSEMBLY INSTRUCTIONS GG77. BASE SIZE: 2.190m x 2.020m ASSEMBLY INSTRUCTIONS GG77 BASE SIZE: 2.190m x 2.020m CONGRATULATIONS ON PURCHASING A DURATUF GUARDIAN SHED. BEFORE YOU BEGIN THE ASSEMBLY PLEASE NOTE SOME IMPORTANT POINTS: BEFORE YOU START: Read all

More information

HOLLOW CORRUGATED SHEETS

HOLLOW CORRUGATED SHEETS P R O D U C T C A T A L O G U E HOLLOW CORRUGATED SHEETS www.tuflite.com Bangalore (Head Office) #240/1, Ganesh Krupa, 18th Cross, Sadashivanagar, Bangalore- 560 080, India P: +91 80 4252 5252 F: +91 80

More information

Tuff-Rib. Installation Manual. Nationwide supplier of quality metal roofing. Toll-Free (800) S. Lee Hwy. Cleveland, TN 37311

Tuff-Rib. Installation Manual. Nationwide supplier of quality metal roofing. Toll-Free (800) S. Lee Hwy. Cleveland, TN 37311 Installation Manual Nationwide supplier of quality metal roofing. 65 S. Lee Hwy. Cleveland, TN 7.. www.bestbuymetals.com Toll-Free (800) 78-00 IMPORTANT NOTICE This manual contains suggestions and guidelines

More information

REGAL. Installation Manual

REGAL. Installation Manual REGAL Installation Manual General Information The details shown on the following pages are suggestions or guidelines for installing the Regal system. The installation details shown here are proven methods

More information

Steeline X-SPAN purlins

Steeline X-SPAN purlins Steeline X-SPAN purlins DESIGN MANUAL F y y L R5 t D 2 Origin x x x x y D L steeline.com.au y y E CONTENTS IMPORTANT NOTES... 1-1 DISCLAIMER... 1-1 INTRODUCTION... 1-2 HOW TO USE THE X-SPAN purlins DESIGN

More information

Hugger Installation. Roof Hugger, LLC P: P.O. Box 1027 F: Odessa, FL

Hugger Installation. Roof Hugger, LLC P: P.O. Box 1027 F: Odessa, FL RECEIVING MATERIALS: ROOF HUGGERS are typically placed on wood pallets 3-5 wide and approximately 10 long weighing up to 5,000 lbs. ROOF HUGGERS are shipped via closed van for LTL less than truckload quantities

More information

ASSEMBLY INSTRUCTIONS GL75. BASE SIZE: 2.190m x 1.520m

ASSEMBLY INSTRUCTIONS GL75. BASE SIZE: 2.190m x 1.520m ASSEMBLY INSTRUCTIONS GL75 BASE SIZE: 2.190m x 1.520m CONGRATULATIONS ON PURCHASING A DURATUF GUARDIAN SHED. BEFORE YOU BEGIN THE ASSEMBLY PLEASE NOTE SOME IMPORTANT POINTS: BEFORE YOU START: Read all

More information

About Everite and Nutec 2. Nutec Bigsix Tiles : Compsition and Product Quality 4. Installation Guide 5. Support Structure 6

About Everite and Nutec 2. Nutec Bigsix Tiles : Compsition and Product Quality 4. Installation Guide 5. Support Structure 6 c o n t e n t s About Everite and Nutec 2 Nutec Bigsix Tiles : Compsition and Product Quality 4 Installation Guide 5 Support Structure 6 Light Weight Steel Sections 4 Timber Supports 5 Mitre Details 5

More information

BARRELL VAULT BATTENLESS

BARRELL VAULT BATTENLESS i BARRELL VAULT BATTENLESS INSTALLATION GUIDE INSTALLATION NOTIFICATION The installation procedures demonstrated in this manual are recommended methods for the installation of the Gerard Barrel Vault battenless

More information

GABLE ROOF CARPORT RECOMMENDED INSTRUCTION MANUAL

GABLE ROOF CARPORT RECOMMENDED INSTRUCTION MANUAL GABLE ROOF CARPORT RECOMMENDED INSTRUCTION MANUAL Table of Contents Introduction 2 Components 3 Step 1a Marking out the Perimeter of the Carport with Footing only 3 Step 2a Footing Set-Out for Concrete

More information

SLATE & SHINGLE INSTALLATION

SLATE & SHINGLE INSTALLATION EAVE EDGE Apply a small strip of roofing paper to the bottom of eave. Eave flashing is attached to substrate with roofing nails every 9". Install underlayment over entire roof. (See Fig. 1) PAGE 1 Bend

More information

ASSEMBLY INSTRUCTIONS SS2520. BASE SIZE: 2.520m x 2.020m

ASSEMBLY INSTRUCTIONS SS2520. BASE SIZE: 2.520m x 2.020m ASSEMBLY INSTRUCTIONS SS50 BASE SIZE:.50m x.00m CONGRATULATIONS ON PURCHASING A SMART STORE SHED. BEFORE YOU BEGIN THE ASSEMBLY PLEASE NOTE SOME IMPORTANT POINTS: BEFORE YOU START: Read all instructions

More information

When you need a clearspan of up to 6 metres of longrun steel you need...

When you need a clearspan of up to 6 metres of longrun steel you need... YEARS OF BUILDING TECHNOLOGY When you need a clearspan of up to 6 metres of longrun steel you need... The proven longrun roofing and cladding system STYLISH Bold profile. High rib (75mm). Internal partitioning.

More information

DUTCH GABLE FREESTANDING CARPORT

DUTCH GABLE FREESTANDING CARPORT DUTCH GABLE FREESTANDING CARPORT STRATCO OUTBACK ASSEMBLY INSTRUCTIONS. Your complete guide to building a FREESTANDING Outback DUTCH GABLE CARPORT BEFORE YOU START Carefully read these instructions. If

More information

CURVED ROOF ASSEMBLY INSTRUCTIONS ATTACHED VERANDAH. Your supplementary guide to building an ATTACHED CURVED ROOF VERANDAH or PATIO BEFORE YOU START

CURVED ROOF ASSEMBLY INSTRUCTIONS ATTACHED VERANDAH. Your supplementary guide to building an ATTACHED CURVED ROOF VERANDAH or PATIO BEFORE YOU START ROOF ATTACHED VERANDAH ASSEMBLY INSTRUCTIONS Your supplementary guide to building an ATTACHED ROOF VERANDAH or PATIO This set of instructions should be used in conjunction with the Stratco instruction

More information

Nutec Bigsix Roofing Accessories

Nutec Bigsix Roofing Accessories Nutec Bigsix Roofing Accessories Nutec Bigsix Close Fitting Adjustable Ridge Capping (Grey) Adjustable for 0º - 0º pitches 70-000 87 mm 70-00 87 mm Nutec Bigsix Close Fitting Adjustable Ridge Capping (Terracotta)

More information

Installation Guide. Step 3. Valley Flashing. Step 7. Transition Flashings and Accessories. Step 6. Hip and Ridge Installation

Installation Guide.   Step 3. Valley Flashing. Step 7. Transition Flashings and Accessories. Step 6. Hip and Ridge Installation Step 7. Transition s and Accessories Step 3. Valley Step 6. Hip and Ridge Installation Step 2. Rake Trim Step 5. Installing the Shingles Step 1. Eave Starter Installation Step 4. Endwall s Installation

More information

GLOSSARY OF TERMS SECTION 8

GLOSSARY OF TERMS SECTION 8 GLOSSARY OF TERMS SECTION 8 Anchor Bolt Angle Base Plate Bay Blocking CCB Centerline Chord Cladding Clip Closure Strip An A-307 steel bolt embedded in the concrete footing to anchor the base plate of the

More information

SpeedDeck. Fixing and Handling Guide

SpeedDeck. Fixing and Handling Guide SpeedDeck Section 1 Delivery/Storing On Site/Handling l SpeedDeck is factory or on-site manufactured. l Straight SpeedDeck bundles are a maximum 1 tonne, sheets nestled and banded with polypropylene or

More information

DW HORIZONTAL INSTALLATION

DW HORIZONTAL INSTALLATION AR-PJ-01-DW2H 2" HORIZONTAL PANEL JOINT AR-PJ-02-DW2H 2" VERTICAL PANEL JOINT AR-PJ-03-DW2H 3" HORIZONTAL PANEL JOINT AR-PJ-04-DW2H 3" VERTICAL PANEL JOINT AR-PJ-05-DW2H CUSTOM REVEAL AR-PJ-06-DW2H DW-2000S

More information

S-Rib Corrugated. Tough and Timeless in Every Sense

S-Rib Corrugated. Tough and Timeless in Every Sense S-Rib Corrugated Tough and Timeless in Every Sense Fielders S-Rib Corrugated. Tough. And timeless in every sense. A reliable product that stands the test of time, Fielders S-Rib Corrugated can be used

More information

Installation Manual. Last Updated 4 February, Postal PO Box 932 Bayswater VIC

Installation Manual. Last Updated 4 February, Postal PO Box 932 Bayswater VIC Installation Manual Last Updated 4 February, 2013 Part 1: Provided Material The Panel Expandable Foam Sealing Strip Barge Capping Z-Fascia Structural Screws Timber: 3/8 head size Metal: 5/16 head size

More information

Five Star Panel Installation Instructions

Five Star Panel Installation Instructions Five Star Panel Installation Instructions How to Store Five Star Panels You will need to store FIVE STAR PANELS in dry place to prevent staining, deterioration and possibly void all warranties. Stand the

More information

Barrel Vault Counter Batten and Batten

Barrel Vault Counter Batten and Batten Barrel Vault Counter Batten and Batten INSTALLATION GUIDE www.gerardusa.com INSTALLATION NOTIFICATION The installation procedures demonstrated in this manual are recommended methods for the installation

More information

Shingle Installation Guide

Shingle Installation Guide Installation Guide Roof Framing Information Installation Installation Accessory Installation Estimating Data General Information Roof Framing Information It is the responsibility or roofers, building contractors

More information

DESIGNER SERIES GUTTER SYSTEM INSTALLATION INSTRUCTIONS

DESIGNER SERIES GUTTER SYSTEM INSTALLATION INSTRUCTIONS DESIGNER SERIES GUTTER SYSTEM INSTALLATION INSTRUCTIONS GENERAL DESCRIPTION: The Designer Series Gutter System is a specially designed roof edge drainage product for industrial, commercial, and high end

More information

ASSEMBLY INSTRUCTIONS SS2010. BASE SIZE: 2.020m x 1.020m

ASSEMBLY INSTRUCTIONS SS2010. BASE SIZE: 2.020m x 1.020m ASSEMBLY INSTRUCTIONS SS010 BASE SIZE:.00m x 1.00m CONGRATULATIONS ON PURCHASING A SMART STORE SHED. BEFORE YOU BEGIN THE ASSEMBLY PLEASE NOTE SOME IMPORTANT POINTS: BEFORE YOU START: Read all instructions

More information

Everbright E610 polycarbonate light panels Installation guidance

Everbright E610 polycarbonate light panels Installation guidance Everbright E610 polycarbonate light panels Installation guidance Mono-pitched applications: Eaves For pitched roofs above 0-degree fix aluminium angle EL17 to supporting structure with self drilling screws

More information

DUTCH GABLE CARPORT RECOMMENDED INSTRUCTION MANUAL

DUTCH GABLE CARPORT RECOMMENDED INSTRUCTION MANUAL DUTCH GABLE CARPORT RECOMMENDED INSTRUCTION MANUAL Table of Contents Introduction 2 Components 3 Step 1a Marking out the Perimeter of the Carport with Footing only 4 Step 2a Footing Set-Out for Concrete

More information

Installation Instructions

Installation Instructions Installation Instructions ROLL VENT STANDARD / METRIC Page Installation Considerations 3 Roll Vent Standard General Installation 4 Roll Vent Metric General Installation 5 Steep Pitch Guidelines 6 Asphalt

More information

SolarMount (E)volution

SolarMount (E)volution SolarMount (E)volution SOLARMOUNT (E)VOLUTION: THE BEST JUST GOT BETTER. Engineering, Excellence, and Ease. Performance Engineered for versatility and reduced installation time, SolarMount (E)volution

More information

Design & Install Guide. The New Standard for Commercial Roof Laps. End-Lap Solution for Insulated Panel Roofing AS WEATHER RESISTANCE

Design & Install Guide. The New Standard for Commercial Roof Laps. End-Lap Solution for Insulated Panel Roofing AS WEATHER RESISTANCE End-Lap Solution for Insulated Panel Roofing AS4046.9 WEATHER RESISTANCE The New Standard for Commercial Roof Laps SecureLap provides a solution to the troublesome sheet to sheet endlap and offers a real

More information

COMPONENTS OF THE CLICKFAST FASCIA AND GUTTER SYSTEM 5: INTERNAL MITRE

COMPONENTS OF THE CLICKFAST FASCIA AND GUTTER SYSTEM 5: INTERNAL MITRE INTRODUCING THE CLICKFAST FASCIA AND GUTTER SYSTEM The Clickfast Fascia and Gutter System was originally designed by Stratco and has proven to be the most successful fascia and gutter system in Australia

More information

Metroll. Purlins & Girts. C Section Purlins. C Section Purlins are manufactured from Galvaspan steel and are roll formed into C Section.

Metroll. Purlins & Girts. C Section Purlins. C Section Purlins are manufactured from Galvaspan steel and are roll formed into C Section. C Section Purlins C Section Purlins are manufactured from Galvaspan steel and are roll formed into C Section. Metroll C Section Purlins are recommended for simple, non-continuous span construction. Structural

More information

Best Buy Metals Toll Free / Phone / Fax

Best Buy Metals Toll Free / Phone / Fax DETAIL MANUAL for Vertical Seam Best Buy Metals Toll Free 1-800-728-4010 / Phone 423-479-6382 / Fax 423-728-3066 www.bestbuymetals.com Vertical Seam Roofing Panels Fig. 2 Vertical Seam Has 1-3/4" high

More information

Installation Procedures

Installation Procedures Installation Procedures Nutec Bigsix Roofing sheets properly laid and fixed in accordance with recommendations will provide many years of trouble-free protection from the elements. Failure to follow these

More information

Installation Instructions

Installation Instructions Installation Instructions RAPID RIDGE STANDARD / 7 / METRIC Page Installation Considerations 3 Rapid Ridge Standard General Installation 4 Rapid Ridge Metric General Installation 5 Rapid Ridge 7 General

More information

IDAHO ASSEMBLY INSTRUCTIONS. BASE SIZE: 1.800m x 1.200m

IDAHO ASSEMBLY INSTRUCTIONS. BASE SIZE: 1.800m x 1.200m IDAHO ASSEMBLY INSTRUCTIONS BASE SIZE: 1.800m x 1.200m IDAHO Tools Required: Battery Drill Riveter Hammer Tape Measure Ladder Skillsaw Level Square Drive Bit No.2 3/8 Hex Drive Bit 8mm Hex Drive Bit Drill

More information

Table of Contents Light Gauge Metal Roof & Wall Panels

Table of Contents Light Gauge Metal Roof & Wall Panels Table of Contents Light Gauge Metal Roof & Wall Panels Installation Guide for Delta Rib, Nor-Clad, Strata Rib & 2-1/2 Corrugated Introduction Important Notice Notes: April 2008 Minimum Recommended Tools

More information

TEST SERIES TO EVALUATE THE STRUCTURAL BEHAVIOUR OF ISOBOARD OVER RAFTER SYSTEM

TEST SERIES TO EVALUATE THE STRUCTURAL BEHAVIOUR OF ISOBOARD OVER RAFTER SYSTEM TEST SERIES TO EVALUATE THE STRUCTURAL BEHAVIOUR OF ISOBOARD OVER RAFTER SYSTEM J A Wium Institute of Structural Engineering 19 November 2007 ISI2007-3 TEST SERIES TO EVALUATE THE STRUCTURAL BEHAVIOUR

More information

Metal Roof Installation Manual. Chapter 14: Fasteners

Metal Roof Installation Manual. Chapter 14: Fasteners Metal Roof Installation Manual Chapter 14: Fasteners Chapter 14: Fasteners Chapter Contents 14. Introduction... 14-1 14.1 Fastener Parts and Installation... 14-1 14.1.1 Points... 14-1 14.1.2 Heads... 14-1

More information

DETAIL MANUAL for Standing Seam / Image II

DETAIL MANUAL for Standing Seam / Image II DETAIL MANUAL for Standing Seam / Image II Best Buy Metals Toll Free 1-800-728-4010 / Phone 423-479-6382 / Fax 423-728-3066 www.bestbuymetals.com Best Buy Metals Standing Seam Roofing Panels Fig. 2 Standing

More information

ALPINE TRAY. To get the best from this product please follow these recommendations.

ALPINE TRAY. To get the best from this product please follow these recommendations. F I X I N G D E TA I L S ALPINE TRAY The standing seam roofing profile is designed to withstand some of New Zealand s harshest weather in our toughest environments. To get the best from this product please

More information

ROOF FRAMING INFORMATION BATTEN INSTALLATION CORONA SHAKE INSTALLATION ACCESSORY INSTALLATION ESTIMATING DATA GENERAL INFORMATION

ROOF FRAMING INFORMATION BATTEN INSTALLATION CORONA SHAKE INSTALLATION ACCESSORY INSTALLATION ESTIMATING DATA GENERAL INFORMATION ROOF FRAMING INFORMATION BATTEN INSTALLATION CORONA SHAKE INSTALLATION ACCESSORY INSTALLATION ESTIMATING DATA GENERAL INFORMATION ROOF FRAMING INFORMATION It is the responsibility or roofers, building

More information

CLEARSPAN GABLE STRATCO OUTBACK ASSEMBLY INSTRUCTIONS. WITH GAZEBO END ATTACHED PATIO

CLEARSPAN GABLE STRATCO OUTBACK ASSEMBLY INSTRUCTIONS. WITH GAZEBO END ATTACHED PATIO CLEARSPAN GABLE WITH GAZEBO END ATTACHED PATIO STRATCO OUTBACK ASSEMBLY INSTRUCTIONS. Your supplementary guide to building an ATTACHED CLEARSPAN GABLE VERANDAH or PATIO WITH GAZEBO END This set of instructions

More information

Chapter 16: Roof Steel

Chapter 16: Roof Steel Chapter 16: Roof Steel Most Common Mistakes: 1. Roof purlins not checked for alignment. 2. Failure to properly square roof. 3. Reversing steel laps. 4. Using not enough or too many screws. 5. Over or under

More information

ENGINEERING STRENGTH INSTAL L AT I O N M A NUAL OUR STRENGTH IS OUR STRENGTH

ENGINEERING STRENGTH INSTAL L AT I O N M A NUAL OUR STRENGTH IS OUR STRENGTH ENGINEERING STRENGTH INSTAL L AT I O N M A NUAL OUR STRENGTH IS OUR STRENGTH RAFTER PREPERATION RAFTER PREPARATION A FRAME PREPERATION AND ASSEMBLY A FRAME PREPARATION AND ASSEMBLY... Open boxes, remove

More information

900 SERIES PANEL SHEET INDEX STAGGERED ENDLAP STAGGERED MALE LEG AT ENDLAP CONTINUOUS FEMALE ENDLAP INSTALLATION SEQUENCE CI-WR

900 SERIES PANEL SHEET INDEX STAGGERED ENDLAP STAGGERED MALE LEG AT ENDLAP CONTINUOUS FEMALE ENDLAP INSTALLATION SEQUENCE CI-WR 900 SERIES PANEL CI-DS-01-900 CI-PJ-01-900 CI-PJ-02-900 CI-EL-01-900 CI-EL-02-900 CI-EL-03-900 CI-EL-04-900 CI-EL-05-900 CI-EL-06-900 CI-EL-07-900 CI-EL-08-900 CI-RD-01-900 CI-RD-02-900 CI-RD-03-900 CI-EV-01-900

More information

range of colours in COLORBOND factory pre-painted steel and in unpainted

range of colours in COLORBOND factory pre-painted steel and in unpainted SPANDEK LYSAGHT SPANDEK Trapezoidal steel cladding Roofing & Walling Solutions LYSAGHT SPANDEK is a contemporarylooking, trapezoidal profile which is ideal where a stronger, bolder, more modern corrugated

More information

TABLE OF CONTENTS A. PBR

TABLE OF CONTENTS A. PBR TABLE OF CONTENTS A. PBR Panel 1. PBR Panel Architect/Engineer Information....................................... 2 2. PBR Panel UL 90 Requirements............................................... 3 3. PBR

More information

Stone coated steel roof tile INSTALLATION GUIDE

Stone coated steel roof tile INSTALLATION GUIDE Stone coated steel roof tile INSTALLATION GUIDE Ⅰ. Introduction These installation details are provided to demonstrate recommended installation methods for KD One roof products and accessories. Consult

More information

Clopay Models 835/837 Sliding Door System Installation Guide

Clopay Models 835/837 Sliding Door System Installation Guide Clopay Models 835/837 Sliding Door System Installation Guide The aim of this instruction is to guide you through the process of construction and fitting of Sliding Doors. Due to the number of sizes available

More information

400 SERIES VERTICAL INSTALLATION

400 SERIES VERTICAL INSTALLATION CI-DS-01-400V CI-PJ-01-400V CI-PJ-02-400V CI-PJ-03-400V CI-BS-01-400V CI-BS-02-400V CI-BS-03-400V CI-BS-04-400V CI-BS-05-400V CI-OC-01-400V CI-OC-02-400V CI-IC-01-400V CI-IC-02-400V CI-FO-01-400V CI-FO-02-400V

More information

NEVADA ASSEMBLY INSTRUCTIONS

NEVADA ASSEMBLY INSTRUCTIONS NEVADA ASSEMBLY INSTRUCTIONS BASE SIZE: 2.700m x 1.500m NEVADA Tools Required: Battery Drill Riveter Hammer Tape Measure Ladder Skillsaw Level Screwdriver - Flat 3/8 Hex Drive bit 8mm Hex Drive bit Drill

More information

The Roofing Store TRS 9 35MM 78MM 150MM 78MM PRODUCT TECHNICAL DATA

The Roofing Store TRS 9 35MM 78MM 150MM 78MM PRODUCT TECHNICAL DATA TRS 9 35MM 78MM 150MM 78MM THICKNESS END SPAN INTERNAL SPAN MINIMUM PITCH 0.55MM 2.30M 3.20M 3 DESCRIPTION TRS 9 profile is designed for commercial and industrial roofing. The profile is suitable for low

More information

CROSSBAR RAFTER ISOMETRIC

CROSSBAR RAFTER ISOMETRIC Super Sky Products' typical glazing system consists of glass panels or "lites" which are attached to the main framing members using extruded aluminum "retainers" or "pressure plates". These retainers are

More information

Polytegola N. Bitumen Roof shingles. Application guide

Polytegola N. Bitumen Roof shingles. Application guide Polytegola N Bitumen Roof shingles Application guide Application manual POLYTEGOLA N CONTENT 1. Foreword - General conditions 3 2. POLYTEGOLA N designs 4 3. Roof pitches 5 4. Storage 5 5. Roof decking

More information

SpeedZip. Fixing and Handling Guide

SpeedZip. Fixing and Handling Guide Section 1 Delivery/Storing On Site/Handling l SpeedZip is factory or on-site manufactured. l Straight SpeedZip bundles are a maximum 1 tonne, 2 No. sheets nestled and then and placed face to face, banded

More information

KS SERIES - VERTICAL INSTALLATION

KS SERIES - VERTICAL INSTALLATION CS-DS-01-KSV CS DISCLAIMER CS-PJ-01-KSV KS42SL EXPANDED PANEL JOINT CS-PJ-02-KSV KS42SL ENGAGED PANEL JOINT CS-PJ-03-KSV KS45SL EXPANDED PANEL JOINT CS-PJ-04-KSV KS45 FLAT ENGAGED PANEL JOINT CS-PJ-05-KSV

More information

TOPSPAN 22 / 40 LYSAGHT TOPSPAN 22 / 40. Steel roof and ceiling battens for non cyclonic applications

TOPSPAN 22 / 40 LYSAGHT TOPSPAN 22 / 40. Steel roof and ceiling battens for non cyclonic applications TOPSPAN 22 / 40 LYSAGHT TOPSPAN 22 / 40 Steel roof and ceiling battens for non cyclonic applications Our TOPSPAN 22 ceiling batten and TOPSPAN 40 roof battens are the economical alternative to timber battens.

More information

NewTech - CleverDeck Composite Decking Installation Guidelines

NewTech - CleverDeck Composite Decking Installation Guidelines NewTech - CleverDeck Composite Decking Installation Guidelines Composite decking has unique characteristics and requires specific fixing requirements that differ from timber. We strongly recommend that

More information

Table of Contents. Installation Guide for Profile with Hidden Fasteners 3. Installation Steps 4, 5. Prestige Series Moldings 6, 7. Other Accessories 8

Table of Contents. Installation Guide for Profile with Hidden Fasteners 3. Installation Steps 4, 5. Prestige Series Moldings 6, 7. Other Accessories 8 1 Table of Contents Page(s) Installation Guide for Profile with Hidden Fasteners 3 Installation Steps 4, 5 Prestige Series Moldings 6, 7 Other Accessories 8 Trims & Accessories 9 Eave Starters 10 Gableboards

More information

TRADITIONAL GABLE ATTACHED PATIO AND CARPORT. Your complete guide to building an ATTACHED Outback TRADITIONAL GABLE PATIO or CARPORT

TRADITIONAL GABLE ATTACHED PATIO AND CARPORT. Your complete guide to building an ATTACHED Outback TRADITIONAL GABLE PATIO or CARPORT TRADITIONAL GABLE ATTACHED PATIO AND CARPORT STRATCO OUTBACK ASSEMBLY INSTRUCTIONS. Your complete guide to building an ATTACHED Outback TRADITIONAL GABLE PATIO or CARPORT BEFORE YOU START Carefully read

More information

GROWING BETTER THROUGH DESIGN. 6ft Lean-To LEAN-TO. Assembly Instructions 04/02

GROWING BETTER THROUGH DESIGN. 6ft Lean-To LEAN-TO. Assembly Instructions 04/02 GROWING BETTER THROUGH DESIGN 6ft Lean-To LEAN-TO Assembly Instructions 04/02 6ft Lean-To Greenhouse Base Plan Introduction/Tools/Contents / / Contents This is a copy of our Lean-To greenhouse base plan.

More information

FIXING GUIDE. Designed for Garages & Sheds, Houses, DIY, Flat Roofs, Industrial & Agricultural Buildings etc. IS THE LONG TERM ROOFING SOLUTION

FIXING GUIDE. Designed for Garages & Sheds, Houses, DIY, Flat Roofs, Industrial & Agricultural Buildings etc. IS THE LONG TERM ROOFING SOLUTION FIXING GUIDE Designed for Garages & Sheds, Houses, DIY, Flat Roofs, Industrial & Agricultural Buildings etc. IS THE LONG TERM ROOFING SOLUTION Permaroof Permaroof Permaroof Profile Roofing Manufacturers

More information

900 SERIES WALL PANELS

900 SERIES WALL PANELS CI-DS-01-900 CI-PP-01-900 CI-PJ-01-900 CI-PJ-02-900 CI-PJ-03-900 CI-BS-01-900 CI-BS-02-900 CI-BS-03-900 CI-BS-04-900 CI-BS-05-900 CI-OC-01-900 CI-OC-02-900 CI-IC-01-900 CI-FO-01-900 CI-FO-02-900 CI-FO-03-900

More information

Table of Contents. Fasteners... 4 Venting Preparation Installation with Battens - DECRA Tile & DECRA Shake 1

Table of Contents. Fasteners... 4 Venting Preparation Installation with Battens - DECRA Tile & DECRA Shake 1 Table of Contents DECRA Tile & Shake Roof Overview... 2 Introduction... 3 Safety... 3 Tools.... 3 Estimating Sheets... 4 Codes & Requirements... 4 Roof Slope... 4 Underlayment... 4 Deck Preparation....

More information

SUNLITE Plus. Installation Instructions for Greenhouses. Multiwall Polycarbonate Sheet with Built-in Condensation Control

SUNLITE Plus. Installation Instructions for Greenhouses.  Multiwall Polycarbonate Sheet with Built-in Condensation Control SUNLITE Plus Multiwall Polycarbonate Sheet with Built-in Condensation Control Installation Instructions for Greenhouses www.palram.com SUNLITE Plus Contents Chapter Page Sheet Dimensions 2 Distance Between

More information

Table of Contents. Roof to Head Wall w/ Side Flashing DECRA Shake XD Roof Overview Roof Penetration - Pipes & Vents...

Table of Contents. Roof to Head Wall w/ Side Flashing DECRA Shake XD Roof Overview Roof Penetration - Pipes & Vents... Table of Contents DECRA Shake XD Roof Overview.... 2 DECRA Shingle XD Roof Overview.... 3 Introduction... 4 Safety... 4 Tools.... 4 Estimating Sheet... 4 Codes & Requirements... 4 Roof Slope... 4 Underlayment...

More information

The Roofing Industry Committee

The Roofing Industry Committee The Roofing Industry Committee on Weather Issues (RICOWI) dispatched seven teams to investigate damage after Hurricane Charley hit the U.S. on August 13, 2004, and five teams after Hurricane Ivan made

More information

MULTISPAN GABLE WITH HIP END ATTACHED PATIO

MULTISPAN GABLE WITH HIP END ATTACHED PATIO MULTISPAN GABLE WITH HIP END ATTACHED PATIO STRATCO OUTBACK ASSEMBLY INSTRUCTIONS. Your supplementary guide to building an ATTACHED MULTISPAN GABLE VERANDAH or PATIO WITH HIP END This set of instructions

More information

NAIMA. Insulation Between (filling) Purlins and Over Purlins. What Does Metal Building Insulation Do? Installation Instructions for New Construction

NAIMA. Insulation Between (filling) Purlins and Over Purlins. What Does Metal Building Insulation Do? Installation Instructions for New Construction Installation Instructions for New Construction Step 8: Insulation Installation Insulation Between (filling) Purlins and Over Purlins Insulation between the Purlin Cavities Unroll and place unfaced metal

More information

CONTENTS. Transitions Board and Batten Vertical Installation... 10,11

CONTENTS. Transitions Board and Batten Vertical Installation... 10,11 INSTALLATION MANUAL CONTENTS Important Notes... 2-4 Weather Protective Barriers... 2 Storage and Transportation... 2 Tools and Equipment... 2 Fastener Choices... 3 Wall Preparation... 3,4 Flashing... 4

More information

INSTALLATION INSTRUCTIONS IMPERVIA (Vent and Fixed) AWNING, CASEMENT, and LARGE AWNING WINDOW WITH FINS

INSTALLATION INSTRUCTIONS IMPERVIA (Vent and Fixed) AWNING, CASEMENT, and LARGE AWNING WINDOW WITH FINS 2012 Pella Corporation Part Number: 80WH0101 INSTALLATION INSTRUCTIONS IMPERVIA (Vent and Fixed) AWNING, CASEMENT, and LARGE AWNING WINDOW WITH FINS Installation Instructions for Typical Wood Frame Construction.

More information

Installation Manual for Metal Emperor Lockers

Installation Manual for Metal Emperor Lockers P a g e 1 Table of Contents Page General Notes and Tools Required 2-3 Assemble Shelves with Coat Hooks/Coat Rods 4 Fastening Chart 5 Knock Down Locker Assembly (Banks of Three) 6-12 Appendix A: Dress End

More information

Installation Instructions for New Construction. Installation Instructions for New Construction

Installation Instructions for New Construction. Installation Instructions for New Construction Installation Instructions for New Construction Installation Instructions for New Construction Step 1: Receipt and Inspection of Material Step 2: Banding Preparation Step 3: Parallel Band Installation Step

More information

INSTALLATION GIUDE.

INSTALLATION GIUDE. INSTALLATION GIUDE INTRODUCTION The instructions and drawings included here are intended only as a guide for the installation of ECO Roofing Systems Spanish and Modern profiles. The materials and methods

More information

ONDUVILLA. The Attractive Alternative to Shingles I N S T A L L A T I O N I N S T R U C T I O N S

ONDUVILLA. The Attractive Alternative to Shingles I N S T A L L A T I O N I N S T R U C T I O N S ONDUVILLA The Attractive Alternative to Shingles I N S T A L L A T I O N I N S T R U C T I O N S 1 INSTALLATION INSTRUCTIONS Even though ONDUVILLA is easy to install, it is important to read through these

More information

INSTALLATION GUIDE LEARN MORE AT DECRA.COM

INSTALLATION GUIDE LEARN MORE AT DECRA.COM Villa Tile INSTALLATION GUIDE LEARN MORE AT DECRA.COM Table of Contents DECRA Villa Tile Roof Overview... 2 Introduction... 3 Safety... 3 Tools.... 3 Estimating Sheet... 3 Codes & Requirements... 3 Roof

More information

Installation Manual. Future Roof Shingle / Slate Products

Installation Manual. Future Roof Shingle / Slate Products Installation Manual Future Roof Shingle / Slate Products REVISED 14/09/2010 Future Roof Shingle Installation Manual is a component of Future Roof, Inc. and as such is intended to be used with Future Roof

More information

Storing, Handling, and Cutting Steel Panels

Storing, Handling, and Cutting Steel Panels Storing, Handling, and Cutting Steel s Storing Specifically check your quantities, colors, and lengths All materials should be used as soon as possible Steel bundles should be stored indoors with enough

More information

RIDGEMASTER PLUS CAUTION INSTALLATION INSTRUCTIONS ALWAYS WEAR SAFETY GLASSES TOOLS NEEDED GENERAL GUIDELINES FOR RIDGEMASTER PLUS AND HIPMASTER

RIDGEMASTER PLUS CAUTION INSTALLATION INSTRUCTIONS ALWAYS WEAR SAFETY GLASSES TOOLS NEEDED GENERAL GUIDELINES FOR RIDGEMASTER PLUS AND HIPMASTER INSTALLATION INSTRUCTIONS RIDGEMASTER PLUS CAUTION Before beginning installation read all general guidelines, special notes and installation steps thoroughly and be sure to check and follow all your local

More information

STEEL BUILDINGS RECOMMENDED INSTALLATION GUIDE

STEEL BUILDINGS RECOMMENDED INSTALLATION GUIDE STEEL BUILDINGS RECOMMENDED INSTALLATION GUIDE 3 TO 30 METRE SPAN FRAME FIRST METHOD SUPPLIED BY: Last update 2 May 2008 2008 FBHS (Aust) Pty Limited FBHS (Aust) Pty Limited ABN 83 126 232 504 trading

More information

Stratco Sanctuary INSTALLATION BEFORE YOU START TOOLS REQUIRED GUIDE

Stratco Sanctuary INSTALLATION BEFORE YOU START TOOLS REQUIRED GUIDE INSTALLATION GUIDE Stratco Sanctuary Verandahs, Patios and Carports BEFORE YOU START It is important to check with your Local Government Authority prior to the installation of your new Stratco Sanctuary

More information