Relay modules, Relay sockets, Plug relays

Size: px
Start display at page:

Download "Relay modules, Relay sockets, Plug relays"

Transcription

1 , Relay sockets, Plug relays General information Relay input side (coil) Single relays housed in slim, rail mounting enclosures taking up the minimum of space. Multiple relays (up to 24) in compact rail mounting enclosures with plug-in option. ermination via screw terminal or ribbon cable. Input voltages from volts. AC and DC options. Coil suppression to prevent interference with and damage to associated electronic devices. LED indication that the coil is energized. Electrical isolation between input (coil) and output (contacts) forms an effective barrier to electro-magnetic interference passing in either direction. A1 A1± ± V1 V2 V1 K1 K1 DC input: he supply must be connected with A1 positive and negative. Diode V1 prevents damage if the supply is connected with the reverse polarity. Diode V2 is a flywheel diode which suppresses the back e.m.f. voltage transient at switch-off. he LED indicator will be connected either in series with the coil or in parallel, in which case a current limiting resistor will be used. AC or DC input: he bridge rectifier V1 enables the relay to be used on DC of either polarity or on AC. wo diodes in the bridge will suppress the back e.m.f. voltage transient at switch-off. he LED indicator will be connected in series or parallel with the coil. Single and multiple contacts. Various contact materials for the best possible performance in each application. Rising-clamp screw terminals for efficient wiring. Each terminal can be given an alpha-numeric identification. Label facility for module identification. he operation of sensitive AC relays can be sometimes impaired by inductive or capacitive coupling of stray signals into the input wiring. L1 A resistor can be fitted across the coil to bypass these stray signals. Alternatively, an RC-network will be effective and will dissipate less power when energized. All modules fit onto 35 mm DIN-rail. Many also fit onto assymmetrical G-rail. Some modules have manual override facility. A1 K1 Contact material ypical properties ypical applications Voltage and current levels Silver-nickel 0,15 gold flashed Widely used general purpose material. General purpose. Suitable for inductive loads. V (AgNi 0,15 hv) 10 ma Silver, gold plated Gold plating resists contamination but switching loads greater than General purpose. For low to mid-range loads. 100 mv (Ag htv) 30 V/0,2 A removes the gold. 1 ma Performance reverts to silver. Silver-cadmium oxide Resists welding and burn-out at high voltages. For heavy inductive or capacitive loads. V (AgCdO) ardly used because of environmental reasons 100 ma Palladium silver, Gold/Rhodium high resistance against oxidation; hard material; Low level signals to mid-range loads. 1 mv 5 V (PdAg-AuRh) stable transfer resistance 1 ma 1 A Silver in oxide Resists welding and burn-out at high voltages. Switching circuits with high V (AgSnO) minimal material erosion on off loading 10 ma Silver in oxide, gold plated Gold plating resists contamination but switching loads greater than General purpose. Suitable for 100 mv (AgSnO htv) 30 V/50 ma removes the gold. small and large loads. 1 ma Performance reverts to AgSnO contacts Output side (contacts) When choosing contact material for a particular application, many factors have to be taken into account, for example: voltage, current, nature of the load and the effect on the contact lifetime. Contact life / no. of operations Each load comprises a resistive, capacitive and an inductive component. It is mainly the inductive component which affects the lifetime. Inductive loads such as solenoids, motors and contactors produce a voltage when switched off which is many times greater than supply voltage. his can quickly burn out the contact. In order to increase the lifetime of the contact, the load must be suppressed. In theory, a varistor or resistor/capacitor network (RC) across the contact is possible, 3.7.1

2 , Relay sockets, Plug relays but dangerous leakage currents may flow to the load when the contact is open. In practice, it is better to fit the suppressor across the load, where it is not only safer but is closer to the source of interference. Murrelektronik can supply many types of universal or made-to-measure suppressors. hese suppressors dampen the high voltage transient and reduce the arc at the contacts. Contact life depends upon voltage, current and the nature of the load. Switching capabilities of the various categories he categories are defined by EN 60946, VDE 0660 and IEC 947 and these list the maximum approved current in exactly defined criteria. Category Voltage type ypical application AC AC voltage Switching from resistive load AC 15 AC voltage Switching from inductive load DC DC voltage Switching from inductive load he standards require a minimum lifespan of 6060 cycles in the defined environment. Using EMC suppression modules when switching inductive loads, the lifespan and the allowed current loading of the contact can be greatly increased. his is shown in the table below. Contact material, silver gold flashed Switched Switched Electrical ype of Lifetime voltage current life load multiplication No. of factor V A operations ,5 x } x Resistive 60 0,8 4 x ,4 6 x , ,1 } 24 1,0 2 x 10 5 Inductive 0,1 48 0,5 2 x 10 5 τ 40 ms 0,1 48 0, ,1 220~ 1 5 x ,1 220~ 0,5 2 x 10 } 6 Inductive 0,1 220~ 0,4 4 x 10 6 cos ϕ 0,4 0,1 220~ 0,1 8 x ,1 ypical values for standard relay contacts Wiring techniques When several relays are installed side by side on a rail, common terminals can be joined by means of a linking bar. his eliminates extra wiring and terminals. Some screw terminals have a double entry point enabling 2 wires to be held in one terminal. hese features simplify wiring techniques. For example, 2 or 3 wire sensors can be connected directly to their relay interfaces without the need for an intermediate terminal rail. Suppression of the load Additional Precise ipolar Advantage / Disadvantage switch-off clamping of suppression delay transient Diode large yes (U D ) no Advantages: simple + inexpensive reliable Last UD suitable for any load very low back e.m.f. Disadvantages: DC only increased release time Diode/Zener diode combination medium yes (U ZD ) no Advantages: suitable for any load + to reliable small Last UZD Disadvantages: no damping below U ZD Zener diode + medium yes (U ZD ) yes Advantages: inexpensive (~)(~) to suitable for any load Last small precise clamping voltage UZD AC or DC Disadvantages: no damping below U ZD Varistor + medium yes (U VDR ) yes Advantages: high energy absorption for size (~)(~) to suitable for any load Last VDR small AC or DC UVDR Disadvantages: no damping below U VDR limited lifespan RC-network + medium no yes Advantages: F damping (~)(~) to AC or DC R small no minimum damping voltage Last URC C Disadvantages: must be matched to load limited lifespan 3.7.2

3 MIRO he modules are offered in two sizes: 6.2 mm module housing with integrated relay with 1 C/O contact and common bridges.4 mm module housing with integrated relay with 2 C/O contact and common bridges Connection is via cage clamp terminals or screw terminal. he minus plug link saves space and wiring time. Snaps on to DIN-rail to EN RMM, RMME, RMMDE Width mm. Attractive and functional design. Separation between input and outputs is clearly defined. Each module can be individually labelled. LED indicator. Snaps on to DIN-rail to EN or EN Versions with plug link on the input side simplify wiring, because no loop in of the common is then necessary. From page From page RMMD/RMMD Compact design incorporating clever features. 1 relay with 1 C/O contact or 2 N/O contact with a width of only mm. Up to 50 modules can be linked using the plug link. he RMMD also has a switch with 3 settings «AND-O-AUO» which allows manual operation or simulations to be carried out. Snaps on to DIN-rail to EN (35 mm) and EN (32 mm). From page RM, RME Width 22.5 mm. here are up to 4 relays in each housing. Each can be individually labelled. he modules are offered with screw terminal or plug in screw terminals. his allows them to be replaced in maintenance very quickly. Positive guided contacts are also on offer. Snaps on to DIN and C-rail. From page MIRO imers Compact form 6,2 mm resp.,4 mm. Modules are available as switch on delay, switch off delay and multi-function. Snaps on to DIN-rail to EN Connection is via cage clamp terminals or screw terminal. he minus plug link saves space and wiring time. Page

4 MIRO Relay modules Small, smaller and smallest Murrelektronik was the first manufacturer of slimline relay modules years ago. Murrelektronik is now the first manufacturer of the terminal row module. 6.2 mm module housing with integrated relay with 1 C/O contact and common bridges.4 mm module housing with integrated relay with 2 C/O contact and common bridges Murrelektronik sets trends he minus plug link, a idea from Murreletronik, saves both space and wiring time. no additional common minus terminals no time consuming wiring of the common minuses cost reduction - Safe separation, sealed relay he wide range, which can be used in numerous applications, offer a high degree of security. Whether relay or opto-coupler, the module offer the perfect solution. Safe separation to VDE 0106 and a sealed relay housing are further advantages. he MIRO opto coupler range offer high switching frequencies and noise free operation. Clearly defined technical data from Murrelektronik oth modules and terminals are clearly and permanently labelled. erminal labelling is to EN Each module also has a module label plate for self marking. LED-Status indicator is standard. he max. current specifications shown for the relay are 6 A, although the exact current is given dependent on usage and type. (see page 3.7.2) Individual connection technology Whether you want to use screw terminal or cage clamp terminals Murrelektronik offer a solution. he connection can easily be made because of the user friendly design. he units are also suitable for use in the building installation industry. he building management industry is offered a further advantage with the AND-0-AUO switch, which can act as a circuit breaker

5 MIRO Murrelektronik Interface erminal relays Output relay MR 6,2 mm MR 6,2 mm Output relay Output relay 1 C/O contact 1 N/O contact with enhanced features with enhanced features Common connection up to max. 50 V DC - Ordering data Art.-No. Art.-No. Art.-No. Art.-No. Input voltage spring clamp terminals screw terminals spring clamp terminals screw terminals V DC V DC V AC/DC V DC V AC/DC V AC/DC echnical data Input (coil) Input voltage/current V DC V DC / approx. 18 ma 24 V DC 19,2 30 V DC / approx. 20 ma 24 V AC/DC 19,2 30 V AC/DC / approx. 20 ma 48 V DC V DC / approx. 15 ma 0 V AC/DC 95 5 V AC/DC/ approx. 5 ma 230 V AC/DC V AC/DC/ approx. 5 ma Status indicator LED green echnical data Output (contact) Max. switched voltage 250 V AC/DC Max. switched current 6 A (see table) Min. load current 10 ma/ V DC Max. power rating (voltage dependent) 1500 VA/0 W Contact material Ag Sn O 2 Energise/release/contact bounce time 10/15/1,5 ms Mech./elect. life 2 x 10 7 /load dependent 10 z est isolation voltage 4 kv/ac; safe separation to VDE 0106/VDE 0160 Air and creepage distance 6/8 mm emperature range C Mounting method DIN-rail mounting to EN Dimensions x x 90 x 6,2 x 65 mm 78 x 6,2 x 65 mm Accessories Dimension drawing Load limit curve De-rating curve Switching capabilities ridging link max. 2 A Art.-No U s (V DC) to EN I (A) ridging comb 10-pole, red Art. No ridging comb 10-pole, blue Art.-No Wire chain 16-pole Art.-No Label plate Art.-No ,1 0, I s (A) ( C) When switching inductive loads, we suggest using a suppression module to reduce interference and improve the relay lifespan. Accessories can be found in chapter AC AC 15 DC 24 V 6 A 3 A 1 A 0 V 6 A 3 A 0,2 A 230 V 6 A 3 A 0,1 A 3.7.5

6 MIRO Murrelektronik Interface erminal relays Input relay MR 6,2 mm MR 6,2 mm Input relay Input relay 1 relay / 1 C/O contact 1 relay / 1 N/O contact with enhanced features with enhanced features Common connection up to max. 50 V DC + A1 Ordering data Art.-No. Art.-No. Art.-No. Art.-No. Input voltage spring clamp terminals screw terminals spring clamp terminals screw terminals 24 V DC V AC/DC V DC V AC/DC V AC/DC echnical data Input (coil) Input voltage/current 24 V DC 19,2 30 V DC / approx. 20 ma 24 V AC/DC 19,2 30 V AC/DC / approx. 20 ma 48 V DC V DC / approx. 15 ma 0 V AC/DC 95 5 V AC/DC / approx. 5 ma 230 V AC/DC V AC/DC / approx. 5 ma Status indicator LED yellow echnical data Output (contact) Max. switched voltage 30 V AC/36 V DC * Max. switched current 50 ma * Min. load current 1 ma/ V DC Max. power rating (voltage dependent) 1500 VA/0 W Contact material Ag Sn O 2 Ag Sn O 2 gold plated Energise/release/contact bounce time 10/15/1,5 ms Mech./elect. life 2 x 10 7 /load dependent 10 z est isolation voltage 4 kv/ac; safe separation to VDE 0106/VDE 0160 Air and creepage distance 6/8 mm emperature range C Mounting method DIN-rail mounting to EN Dimensions x x 90 x 6,2 x 65 mm 78 x 6,2 x 65 mm Accessories Dimension drawing Load limit curve De-rating curve ridging link max. 2 A Art.-No ridging comb 10-pole, red Art. No ridging comb 10-pole, blue Art.-No Wire chain 16-pole Art.-No Label plate Art.-No U s (V DC) ,1 0, I s (A) ( C) When switching inductive loads, we suggest using a suppression module to reduce interference and improve the relay lifespan. * When the listed values are exceeded the gold plating is destroyed, the values of the output relay are then valid i.e. on page I (A)

7 MIRO Murrelektronik Interface erminal relays with manual switch to VDI 38 MR 6,2 mm MR 6,2 mm Output relay Input relay 1 relay / 1 N/O contact 1 relay / 1 N/O contact with -O-A switch with -O-A switch Common connection up to max. 50 V DC ±A3 ±A1 ± O A ±A3 ±A1 ± O A Ordering data Art.-No. Art.-No. Art.-No. Art.-No. Input voltage spring clamp terminals screw terminals spring clamp terminals screw terminals 24 V DC 24 V AC/DC V DC 0 V AC/DC 230 V AC/DC echnical data Input (coil) Input voltage/current 24 V DC 24 V AC/DC 19,2 30 V AC/DC / approx. 20 ma 48 V DC 0 V AC/DC 230 V AC/DC Status indicator LED green LED yellow echnical data Output (contact) Max. switched voltage 250 V AC/DC 30 V AC/36 V DC * Max. switched current 6 A (see table) 50 ma * Min. load current 10 ma/ V DC 1 ma/ V DC Max. power rating (voltage dependent) 1500 VA/0 W 1500 VA/0 W Contact material Ag Sn O 2 Ag Sn O 2 gold plated Energise/release/contact bounce time 10/15/1,5 ms Mech./elect. life 2 x 10 7 /load dependent 10 z est isolation voltage 4 kv/ac; safe separation to VDE 0106/VDE 0160 Air and creepage distance 6/8 mm emperature range C Mounting method DIN-rail mounting to EN Dimensions x x 90 x 6,2 x 65 mm Accessories Dimension drawing Load limit curve De-rating curve Switching capabilities ridging link max. 2 A Art.-No U s (V DC) to EN ridging comb 10-pole, red Art. No ridging comb 10-pole, blue Art.-No Wire chain 16-pole Art.-No Label plate Art.-No ,1 0, I s (A) ( C) When switching inductive loads, we suggest using a suppression module to reduce interference and improve the relay lifespan. * When the listed values are exceeded the gold plating is destroyed, the values of the output relay are then valid i.e. on page I (A) AC AC 15 DC 24 V 6 A 3 A 1 A 0 V 6 A 3 A 0,2 A 230 V 6 A 3 A 0,1 A 3.7.7

8 MIRO Murrelektronik Interface erminal relays with opposite common and for 3-wire initiators MR 6,2 mm MR 6,2 mm Output relay Input relay 1 N/O contact 1 N/O contact with integrated looping terminal for 3-wire NPN sensors NC + IN Ordering data Art.-No. Art.-No. Art.-No. Art.-No. Input voltage spring clamp terminals screw terminals spring clamp terminals screw terminals 24 V DC V AC/DC 48 V DC 0 V AC/DC 230 V AC/DC echnical data Input (coil) Input voltage/current 24 V DC 19,2 30 V DC / approx. 20 ma 24 V AC/DC 48 V DC 0 V AC/DC 230 V AC/DC V AC/DC / approx. 5 ma Status indicator LED green LED yellow echnical data Output (contact) Max. switched voltage 250 V AC/DC 30 V AC/36 V DC * Max. switched current 6 A (see table) 50 ma * Min. load current 10 ma/ V DC 1 ma/ V DC Max. power rating (voltage dependent) 1500 VA/0 W 1500 VA/0 W Contact material Ag Sn O 2 Ag Sn O 2 gold plated Energise/release/contact bounce time 10/15/1,5 ms Mech./elect. life 2 x 10 7 /load dependent 10 z est isolation voltage 4 kv/ac; safe separation to VDE 0106/VDE 0160 Air and creepage distance 6/8 mm emperature range C Mounting method DIN-rail mounting to EN Dimensions x x 90 x 6,2 x 65 mm Accessories Dimension drawing Load limit curve De-rating curve Switching capabilities ridging link max. 2 A Art.-No U s (V DC) to EN ridging comb 10-pole, red Art. No ridging comb 10-pole, blue Art.-No Wire chain 16-pole Art.-No Label plate Art.-No ,1 0, I s (A) ( C) When switching inductive loads, we suggest using a suppression module to reduce interference and improve the relay lifespan. * When the listed values are exceeded the gold plating is destroyed, the values of the output relay are then valid i.e. on page I (A) AC AC 15 DC 24 V 6 A 3 A 1 A 0 V 6 A 3 A 0,2 A 230 V 6 A 3 A 0,1 A

9 MIRO Murrelektronik Interface erminal relays with contact isolation link on the output MR 6,2 mm MR 6,2 mm Isolation link relay module Isolation link relay module 1 C/O contact with isolation function 1 N/O contact with isolation function Common connection up to max. 50 V DC IO IO - - Ordering data Art.-No. Art.-No. Art.-No. Art.-No. Input voltage spring clamp terminals screw terminals spring clamp terminals screw terminals 24 V DC 24 V AC/DC V DC 0 V AC/DC 230 V AC/DC echnical data Input (coil) Input voltage/current 24 V DC 24 V AC/DC 19,2 30 V AC/DC / approx. 20 ma 48 V DC 0 V AC/DC 230 V AC/DC Status indicator LED green echnical data Output (contact) Max. switched voltage 250 V AC/DC Max. switched current 6 A (see table) Min. load current 10 ma/ V DC Max. power rating (voltage dependent) 1500 VA/0 W Contact material Ag Sn O 2 Energise/release/contact bounce time 10/15/1,5 ms Mech./elect. life 2 x 10 7 /load dependent 10 z est isolation voltage 4 kv/ac; safe separation to VDE 0106/VDE 0160 Air and creepage distance 6/8 mm emperature range C Mounting method DIN-rail mounting to EN Dimensions x x 90 x 6,2 x 65 mm 78 x 6,2 x 65 mm Accessories Dimension drawing Load limit curve De-rating curve Switching capabilities to EN ridging link max. 2 A Art.-No ridging comb 10-pole, red Art. No ridging comb 10-pole, blue Art.-No Wire chain 16-pole Art.-No Label plate Art.-No U s (V DC) ,1 0, I s (A) ( C) When switching inductive loads, we suggest using a suppression module to reduce interference and improve the relay lifespan. Accessories can be found in chapter 3.16 I (A) AC AC 15 DC 24 V 6 A 3 A 1 A 0 V 6 A 3 A 0,2 A 230 V 6 A 3 A 0,1 A 3.7.9

10 MIRO Murrelektronik Interface erminal relays MR,4 mm MR,4 mm Output relay Input relay 1 relay/2 C/O contacts 1 relay/2 C/O contacts with enhanced features with enhanced features Common connection up to max. 50 V DC Ordering data Art.-No. Art.-No. Art.-No. Art.-No. Input voltage spring clamp terminals screw terminals spring clamp terminals screw terminals 24 V DC V AC/DC V DC V AC/DC V AC/DC echnical data Input (coil) Input voltage/current 24 V DC 19,2 30 V DC / approx. 20 ma 24 V AC/DC 19,2 30 V AC/DC / approx. 20 ma 48 V DC V DC / approx. 15 ma 0 V AC/DC 95 1 V AC/DC / approx. 7 ma 230 V AC/DC V AC/DC / approx. 5 ma Status indicator LED green echnical data Output (contact) Max. switched voltage 250 V AC/DC 30 V AC/36 V DC * Max. switched current 6 A (see table) 50 ma * Min. load current 10 ma/ V DC Max. power rating (voltage dependent) 1500 VA/0 W Contact material Ag Sn O 2 Ag Sn O 2 gold plated Energise/release/contact bounce time 10/15/1,5 ms Mech./elect. life 2 x 10 7 /load dependent 10 z est isolation voltage 4 kv/ac; safe separation to VDE 0106/VDE 0160 Air and creepage distance 6/8 mm emperature range C Mounting method DIN-rail mounting to EN Dimensions x x 90 x,4 x 65 mm Accessories Dimension drawing Load limit curve De-rating curve Switching capabilities ridging link max. 2 A Art.-No U s (V DC) to EN Wire chain 16-pole Art.-No Label plate Art.-No ,1 0, I s (A) ( C) When switching inductive loads, we suggest using a suppression module to reduce interference and improve the relay lifespan. * When the listed values are exceeded the gold plating is destroyed, the values of the output relay are then valid i.e. on page I (A) AC AC 15 DC 24 V 6 A 3 A 1 A 0 V 6 A 3 A 0,2 A 230 V 6 A 3 A 0,1 A

11 MIRO Murrelektronik Interface erminal relays MR,4 mm MR,4 mm Output relay Input relay 2 relays/each 1 C/O contact 2 relays/each 1 C/O contact with enhanced features with enhanced features Common connection up to max. 50 V DC ±A ±1 ± ± Ordering data Art.-No. Art.-No. Art.-No. Art.-No. Input voltage spring clamp terminals screw terminals spring clamp terminals screw terminals 24 V DC V AC/DC V DC V AC/DC V AC/DC echnical data Input (coil) Input voltage/current 24 V DC 19,2 30 V DC / approx. 20 ma 24 V AC/DC 19,2 30 V AC/DC / approx. 20 ma 48 V DC V DC / approx. 10 ma 0 V AC/DC 95 1 V AC/DC / approx. 5 ma 230 V AC/DC V AC/DC / approx. 5 ma Status indicator LED green echnical data Output (contact) Max. switched voltage 250 V AC/DC 30 V AC/36 V DC * Max. switched current 6 A (see table) 50 ma * Min. load current 10 ma/ V DC Max. power rating (voltage dependent) 1500 VA/0 W Contact material Ag Sn O 2 Ag Sn O 2 gold plated Energise/release/contact bounce time 10/15/1,5 ms Mech./elect. life 2 x 10 7 /load dependent 10 z est isolation voltage 4 kv/ac; safe separation to VDE 0106/VDE 0160 Air and creepage distance 6/8 mm emperature range C Mounting method DIN-rail mounting to EN Dimensions x x 90 x,4 x 65 mm Accessories Dimension drawing Load limit curve De-rating curve Switching capabilities ridging link max. 2 A Art.-No U s (V DC) to EN Wire chain 16-pole Art.-No Label plate Art.-No ,1 0, I s (A) ( C) When switching inductive loads, we suggest using a suppression module to reduce interference and improve the relay lifespan. * When the listed values are exceeded the gold plating is destroyed, the values of the output relay are then valid i.e. on page I (A) AC AC 15 DC 24 V 6 A 3 A 1 A 0 V 6 A 3 A 0,2 A 230 V 6 A 3 A 0,1 A 3.7.

12 MIRO Murrelektronik Interface erminal relays MR,4 mm MR,4 mm Output relay Input relay 1 relay/2 C/O contacts 1 relay/2 C/O contacts with -O-A switch with -O-A switch with manual switch to VDI 38 Common connection up to max. 50 V DC ±A3 ±A1 ± ± O A Ordering data Art.-No. Art.-No. Art.-No. Art.-No. Input voltage spring clamp terminals screw terminals spring clamp terminals screw terminals 24 V DC 24 V AC/DC V DC 0 V AC/DC 230 V AC/DC echnical data Input (coil) Input voltage/current 24 V DC 24 V AC/DC 19,2 30 V AC/DC / approx. 20 ma 48 V DC 0 V AC/DC 230 V AC/DC Status indicator LED green echnical data Output (contact) Max. switched voltage 250 V AC/DC 30 V AC/36 V DC * Max. switched current 6 A (see table) 50 ma * Min. load current 10 ma/ V DC Max. power rating (voltage dependent) 1500 VA/0 W Contact material Ag Sn O 2 Ag Sn O 2 gold plated Energise/release/contact bounce time 10/15/1,5 ms Mech./elect. life 2 x 10 7 /load dependent 10 z est isolation voltage 4 kv/ac; safe separation to VDE 0106/VDE 0160 Air and creepage distance 6/8 mm emperature range C Mounting method DIN-rail mounting to EN Dimensions x x 90 x,4 x 65 mm Accessories Dimension drawing Load limit curve De-rating curve Switching capabilities ridging link max. 2 A Art.-No U s (V DC) to EN Wire chain 16-pole Art.-No Label plate Art.-No ,1 0, I s (A) ( C) When switching inductive loads, we suggest using a suppression module to reduce interference and improve the relay lifespan. * When the listed values are exceeded the gold plating is destroyed, the values of the output relay are then valid i.e. on page I (A) AC AC 15 DC 24 V 6 A 3 A 1 A 0 V 6 A 3 A 0,2 A 230 V 6 A 3 A 0,1 A

13 MIRO Murrelektronik Interface erminal relays MR,4 mm MR,4 mm Output relay Input relay 1 relay/1 C/O contact 1 relay/2 C/O contacts with -O-A switch and CL contact for 3-wire NPN sensors Common connection up to max. 50 V DC 1 2 ±A3 ±A1 ± ± O A + IN Ordering data Art.-No. Art.-No. Art.-No. Art.-No. Input voltage spring clamp terminals screw terminals spring clamp terminals screw terminals 24 V DC 24 V AC/DC V DC 0 V AC/DC 230 V AC/DC echnical data Input (coil) Input voltage/current 24 V DC 24 V AC/DC 19,2 30 V AC/DC / approx. 20 ma 48 V DC 0 V AC/DC 230 V AC/DC Status indicator LED green echnical data Output (contact) Max. switched voltage 250 V AC/DC 30 V AC/36 V DC * Max. switched current 6 A (see table) 50 ma * Min. load current 10 ma/ V DC Max. power rating (voltage dependent) 1500 VA/0 W Contact material Ag Sn O 2 Ag Sn O 2 gold plated Energise/release/contact bounce time 10/15/1,5 ms Mech./elect. life 2 x 10 7 /load dependent 10 z est isolation voltage 4 kv/ac; safe separation to VDE 0106/VDE 0160 Air and creepage distance 6/8 mm emperature range C Mounting method DIN-rail mounting to EN Dimensions x x 90 x,4 x 65 mm Accessories Dimension drawing Load limit curve De-rating curve Switching capabilities ridging link max. 2 A Art.-No U s (V DC) to EN Wire chain 16-pole Art.-No Label plate Art.-No ,1 0, I s (A) ( C) When switching inductive loads, we suggest using a suppression module to reduce interference and improve the relay lifespan. * When the listed values are exceeded the gold plating is destroyed, the values of the output relay are then valid i.e. on page I (A) AC AC 15 DC 24 V 6 A 3 A 1 A 0 V 6 A 3 A 0,2 A 230 V 6 A 3 A 0,1 A 3.7.

14 MIRO Murrelektronik Interface erminal relays MR,4 mm MR,4 mm Output relay Input relay 1 relay/2 N/O contacts 1 relay/2 N/O contacts with enhanced features with enhanced features Common connection up to max. 50 V DC ±A1 ± Ordering data Art.-No. Art.-No. Art.-No. Art.-No. Input voltage spring clamp terminals screw terminals spring clamp terminals screw terminals 24 V DC 24 V AC/DC V DC 0 V AC/DC 230 V AC/DC echnical data Input (coil) Input voltage/current 24 V DC 24 V AC/DC 19,2 30 V AC/DC / approx. 20 ma 48 V DC 0 V AC/DC 230 V AC/DC Status indicator LED green echnical data Output (contact) Max. switched voltage 250 V AC/DC 30 V AC/36 V DC * Max. switched current 6 A (see table) 50 ma * Min. load current 10 ma/ V DC Max. power rating (voltage dependent) 1500 VA/0 W Contact material Ag Sn O 2 Ag Sn O 2 gold plated Energise/release/contact bounce time 10/15/1,5 ms Mech./elect. life 2 x 10 7 /load dependent 10 z est isolation voltage 4 kv/ac; safe separation to VDE 0106/VDE 0160 Air and creepage distance 6/8 mm emperature range C Mounting method DIN-rail mounting to EN Dimensions x x 90 x,4 x 65 mm Accessories Dimension drawing Load limit curve De-rating curve Switching capabilities ridging link max. 2 A Art.-No U s (V DC) to EN Wire chain 16-pole Art.-No Label plate Art.-No ,1 0, I s (A) ( C) When switching inductive loads, we suggest using a suppression module to reduce interference and improve the relay lifespan. * When the listed values are exceeded the gold plating is destroyed, the values of the output relay are then valid i.e. on page S I (A) AC AC 15 DC 24 V 6 A 3 A 1 A 0 V 6 A 3 A 0,2 A 230 V 6 A 3 A 0,1 A

15 MIRO Murrelektronik Interface erminal relays for use in building installations MR,4 mm MR,4 mm for long cables Output relay 1 Output relay/1 C/O contact 2 N/O contacts for use in control cabinets in building installations for use in control cabinets in building installations A1 ±A1 23 ± 24 Ordering data Art.-No. Art.-No. Art.-No. Art.-No. Input voltage spring clamp terminals screw terminals spring clamp terminals screw terminals 24 V DC 24 V AC/DC V DC 0 V AC/DC 230 V AC/DC echnical data Input (coil) Input voltage/current 24 V DC 24 V AC/DC 19,2 30 V AC/DC / approx. 20 ma 48 V DC 0 V AC/DC 230 V AC/DC V AC/DC / approx. 5 ma (old voltage 70 V/ old current 0,3 ma) Status indicator LED green echnical data Output (contact) Max. switched voltage 250 V AC/DC Max. switched current 6 A (see table) Min. load current 10 ma/ V DC Max. power rating (voltage dependent) 1500 VA/0 W Contact material Ag Sn O 2 Energise/release/contact bounce time 10/15/1,5 ms Mech./elect. life 2 x 10 7 /load dependent 10 z est isolation voltage 4 kv/ac; safe separation to VDE 0106/VDE 0160 Air and creepage distance 6/8 mm emperature range C Mounting method DIN-rail mounting to EN Dimensions x x 90 x,4 x 65 mm Accessories Dimension drawing Load limit curve De-rating curve Switching capabilities ridging link max. 2 A Art.-No U s (V DC) to EN Wire chain 16-pole Art.-No Label plate Art.-No ,1 0, I s (A) ( C) When switching inductive loads, we suggest using a suppression module to reduce interference and improve the relay lifespan. Accessories can be found in chapter 3.16 I (A) AC AC 15 DC 24 V 6 A 3 A 1 A 0 V 6 A 3 A 0,2 A 230 V 6 A 3 A 0,1 A

16 Mini-Relay modules RMM Output relay with minus plug link RMM Output relay without minus plug link ±A1 ±A1 ±A1 ±A1 ± ± ± ± Ordering data Art.-No. Art.-No. Art.-No. Art.-No. Input voltage 1 relay; 1 N/O contact 1 relay; 1 N/C contact 1 relay; 1 N/O contact 1 relay; 1 N/C contact 24 V DC V DC V AC V AC echnical data Input (coil) Input voltage/current 24 V DC ±10 %/30 ma (24 V AC -5 %, +10 % at ϑ U max. 40 C) 48 V DC ±10 %/20 ma (48 V AC -5 %, +10 % at ϑ U max. 40 C) 0 V AC +10 % -15 %/7 ma 230 V AC +10 % -15 %/7 ma Plug link Art.-No (included with relay) Status indicator LED red echnical data Output (contact) Max. switched voltage 250 V AC/300 V DC Max. switched current 5 A Min. load current 100 ma Max. power rating (voltage dependent) 50 VA/240 W Contact material Ag Ni 0,15 hv; Ag hv Energise/release/contact bounce time 10/15/1,5 ms Mech./elect. life 2 x 10 7 /load dependent 10 z est isolation voltage 4 kv/ac; safe separation to VDE 0106/VDE 0160 emperature range C Mounting method DIN-rail mounting to EN or EN Dimensions x x 56 x x 64 mm Dimension drawing Accessories can be found in chapter

17 Mini-Relay modules with green LED RMM Output relay RMM Output relay - - Ordering data Art.-No. Art.-No. Input voltage 1 relay; 1 N/O contact 1 relay; 1 N/O contact 24 V DC V DC 0 V AC 230 V AC echnical data Input (coil) Input voltage/current 24 V DC ±10 %/20 ma 24 V DC ±10 %/20 ma Status indicator LED green LED green Connection screw terminal coil connection: Faston 2 x 2,8 x 0,8 mm echnical data Output (contact) Max. switched voltage 250 V AC/300 V DC Max. switched current 5 A Min. load current 100 ma Max. power rating (voltage dependent) 50 VA/240 W Contact material Ag Ni 0,15 hv; Ag hv Energise/release/contact bounce time 10/15/1,5 ms Connection screw terminal Mech./elect. life 2 x 10 7 /load dependent 10 z est isolation voltage 4,0 kv AC emperature range C Mounting method DIN-rail mounting to EN or EN Dimensions x x 56 x x 64 mm Dimension drawing Accessories can be found in chapter VW Id.No.: A (5764) and A (5774)

18 Mini-Relay modules RMME Input relay with minus plug link RMME Input relay without minus plug link A1 A1 A1 ±A1 ± Ordering data Art.-No. Art.-No. Art.-No. Art.-No. Input voltage 1 relay; 1 N/O contact 1 relay; 1 N/C contact 1 relay; 1 N/O contact 1 relay; 1 N/C contact 24 V AC/DC V AC/DC V AC V AC echnical data Input (coil) Input voltage/current 24 V AC/DC ±10 %/7 ma 48 V AC/DC ±10 %/7 ma 0 V AC +10 % -15 %/7 ma 230 V AC +10 % -15 %/7 ma Plug link Art.-No (included with relay) Status indicator LED yellow echnical data Output (contact) Max. switched voltage 5 V AC/150 V DC Max. switched current 1 A Min. load current 1 ma Max. power rating (voltage dependent) 60 VA/30 W Contact material Pd Ni-Au Rh Energise/release/contact bounce time 10/10/1 ms Mech./elect. life 1 x 10 8 /load dependent 15 z est isolation voltage 1,5 kv AC emperature range C Mounting method DIN-rail mounting to EN or EN Dimensions x x 56 x x 64 mm Dimension drawing Accessories can be found in chapter

19 RMMD-Relay modules with minus plug link RMMD RMMD RMMD Output relay Output relay Output relay with minus plug link with minus plug link with minus plug link Ordering data Art.-No. Art.-No. Art.-No. Input voltage 1 relay; 1 N/O contact 1 relay; 1 N/C contact 1 relay; 1 C/O contact 24 V DC 1) 500 1) 510 1) V AC/DC 0 V AC 230 V AC 508 echnical data Input (coil) Input voltage/current 24 V DC ±10 %/20 ma Plug link Status indicator echnical data Output (contact) Max. switched voltage Max. switched current Min. load current Max. power rating (voltage dependent) Contact material Energise/release/contact bounce time 230 V AC +10 % -15 %/10 ma (without plug link) Art.-No (included with relay) plug link not possible with 230 V version LED red 250 V AC/DC 8 A (6 A at 230 V-ype) 100 ma 2000 VA/240 W Ag Ni 0,15 hv; Ag hv; 10/15/2 ms Mech./elect. life 2 x 10 7 /load dependent 10 z est isolation voltage 5 kv AC; at Art.-No. 508: 4,0 kv AC emperature range C Mounting method DIN-rail mounting to EN or EN Dimensions x x 82 x x 68 mm Dimension drawing Accessories can be found in chapter ) Units with safe separation to VDE 0106, part 101/VDE

20 RMMD-Relay modules with minus plug link RMMD RMMDE RMMDE RMMDE Output relay Input relay Input relay Input relay with low connection current with enhanced features with enhanced features with enhanced features A Ordering data Art.-No. Art.-No. Art.-No. Art.-No. Input voltage 1 relay; 1 C/O contact 1 relay; 1 N/O contact/1 N/C contact 1 relay; 1 C/O contact 1 relay; 2 N/O contacts 24 V AC/DC 1) V DC V AC 230 V AC 538 echnical data Input (coil) Input voltage/current 24 V AC/DC ±10 %/max. 10 ma 24 V DC ±10 %/max. 20 ma 24 V DC ±10 %/max. 15 ma 24 V DC ±10 %/max. 15 ma 230 V AC +10 % -15 %/10 ma Plug link Art.-No (included with relay) plug link not possible with 230 V version Status indicator LED red LED yellow echnical data Output (contact) Max. switched voltage 250 V AC/DC 250 V AC/DC 5 V AC/150 V DC 250 V AC/DC Max. switched current 8 A 3 A 1 A 2 A Min. load current 100 ma 1 ma 1 ma 5 ma Max. power rating (voltage dependent) 2000 VA/240 W 90 W/VA 60 VA/30 W 250 VA/150 W Contact material Ag Ni 0,15 hv; Ag hv Ag-htv Pd Ni-Au Rh Ag Au-Pd Ag Energise/release/contact bounce time 10/15/2 ms 6/3/2 ms 10/10/1 ms 10/10/1 ms Mech./elect. life 2 x 10 7 /load dependent 2 x 10 7 /load dependent 1 x 10 8 /load dependent 2 x 10 7 /load dependent 10 z 10 z 15 z 15 z est isolation voltage 5 kv AC 1,5 kv AC 1,5 kv AC 1 kv AC emperature range C C C C Mounting method DIN-rail mounting to EN or EN Dimensions x x 82 x x 68 mm Dimension drawing Accessories can be found in chapter ) Units with safe separation to VDE 0106, part 101/VDE 0160

21 RMMD-Relay modules with AND-OFF-AUO for use in uilding Management Systems RMMD Output relay with negative plug-in and toggle switch for AND-0-AUO control RMMD Output relay with negative plug-in and toggle switch for AND-0-AUO control as auxiliary alarm contact when in "AND" position + ( - ) A1 +24 V (A3) (0 V) S (+) - O A +24 S CL - O I Ordering data Art.-No. Art.-No. Art.-No. Input voltage 1 relay; 1 C/O contact 1 relay; 1 C/O contact 1 relay; 1 N/O contact 24 V DC V AC/DC 552 1) V AC 230 V AC echnical data Input (coil) Input voltage/current 24 V DC ±10 %/8 ma 24 V AC/DC ±10 %/20 ma Plug link Art.-No (included with relay) Status indicator LED red echnical data Output (contact) Max. switched voltage 250 V AC/DC 250 V AC/DC Max. switched current 8 A 5 A Min. load current 100 ma 10 ma Max. power rating (voltage dependent) 2000 VA/240 W 750 VA/75 W Contact material relay (switch) Ag Ni 0,15 hv Ag Ni 0,15 hv Energise/release/contact bounce time 10/10/2 ms 10/10/2 ms Mech./elect. life 3 x 10 7 /load dependent 2 x 10 7 /load dependent 15 z 10 z est isolation voltage 3 kv AC 3 kv AC emperature range C C Mounting method DIN-rail mounting to EN or EN DIN-rail mounting to EN or EN Dimensions x x 82 x x 82 mm 82 x x 82 mm Dimension drawing/description his relay enables the load to be controlled by a PLC with the added facility to manually switch the load on or off using the toggle switch. 1) with Art.-No the toggle switch must be held in the AND position. Accessories can be found in chapter

22 RMMD-Relay modules with AND-OFF-AUO RMMD Output relay with negative plug-in and toggle switch for AND-0-AUO control as auxiliary alarm contact when in "AND" position RMMD Output relay with negative plug-in and toggle switch for AND-0-AUO control. Output relay with negative plug link and toggle switch to bridge working contact. CL +24 S - O A - IO Ordering data Art.-No. Art.-No. Input voltage 1 relay; 1 N/O contact 1 relay; 1 N/O contact 24 V DC V DC 0 V AC 230 V AC echnical data Input (coil) Input voltage/current 24 V DC ±10 %/20 ma 24 V DC ±10 %/10 ma Plug link Art.-No (included with relay) Status indicator LED red echnical data Output (contact) Max. switched voltage 250 V AC/DC; CL-Alarm signal 24 V DC 250 V AC/30 V DC Max. switched current 8 A; CL-Alarm signal 10 ma 3 A Min. load current 100 ma 100 ma Max. power rating (voltage dependent) 2000 VA/240 W 750 VA/90 W Contact material relay (switch) Ag Ni 0,15 hv Ag Cd 0 (Ag) Energise/release/contact bounce time 10/10/2 ms 10/10/2 ms Mech./elect. life 3 x 10 7 /load dependent 3 x 10 7 /load dependent 15 z 15 z est isolation voltage 1,5 kv AC 3 kv AC emperature range C C Mounting method DIN-rail mounting to EN or EN DIN-rail mounting to EN or EN Dimensions x x 82 x x 82 mm 82 x x 82 mm Dimension drawing his relay enables the load to be controlled by a PLC with the added facility to manually switch the load on or off using the toggle switch. Art.-No. 501 differs in that the relay contact is bridged by the hand operated switch. Accessories can be found in chapter

23 MCVO-Relay modules RM Output relay ±A1 ± erminal layout different for Art.-No Ordering data Art.-No. Art.-No. Art.-No. Art.-No. Input voltage 1 relay; 2 C/O contacts 1 relay; 4 C/O contacts 2 relay; each 1 C/O contact 2 relay; each 2 C/O contacts 24 V DC V DC V AC V AC echnical data Input (coil) Input voltage/current 24 V DC ±10 %/35 ma 24 V DC ±10 %/30 ma 24 V DC ±10 %/30 ma 48 V DC ±10 %/20 ma 0 V AC +10 % -15 %/15 ma 0 V AC +10 % -15 %/10 ma 230 V AC +10 % -15 %/15 ma 230 V AC +10 % -15 %/10 ma 230 V AC +10 % -15 %/20 ma Status indicator LED red echnical data Output (contact) Max. switched voltage 250 V AC/DC 250 V AC/DC 250 V AC/300 V DC 250 V AC/DC Max. switched current 5 A 2 A 5 A 4 A Min. load current 100 ma 100 ma 100 ma 100 ma Max. power rating (voltage dependent) 50 VA/0 W 100 VA/75 W 50 VA/240 W 1000 VA/100 W Contact material Ag Ni 0,15 Ag hv Ag Ni 0,15 hv; Ag hv Ag Ni 0,15 Energize/release/contact bounce time 10/10/2 ms 10/20/2 ms 10/10/2 ms 10/10/2 ms Mech./elect. life 5 x 10 7 /load dependent 5 x 10 7 /load dependent 2 x 10 7 /load dependent 10 z 10 z 10 z est insulation voltage 4 kv AC 1,0 kv AC 1,5 kv AC emperature range C Mounting method DIN-rail mounting to EN or EN Dimensions x x 75 x 22,5 x 102 mm Dimension drawing 24 ±A1 ± ±A ± A ±1 ± A Accessories can be found in chapter

24 MCVO-Relay modules RM Output relay RM Output relay +A +1 +A Common minus potential for all inputs - Common minus potential for all inputs - Ordering data Art.-No. Art.-No. Input voltage 3 relay; each 1 C/O contact 4 relay; each 1 N/O contact 24 V DC V DC V AC 230 V AC echnical data Input (coil) Input voltage/current 24 V DC ±10 %/20 ma 48 V DC ±10 %/10 ma +A +1 +A31 +A Status indicator LED red echnical data Output (contact) Max. switched voltage 250 V AC/300 V DC Max. switched current 5 A Min. load current 100 ma Max. power rating (voltage dependent) 50 VA/240 W Contact material Ag Ni 0,15 hv; Ag hv Energize/release/contact bounce time 10/10/2 ms Mech./elect. life 2 x 10 7 /load dependent 5 x 10 7 /load dependent 10 z est insulation voltage 1,5 kv AC emperature range C Mounting method DIN-rail mounting to EN or EN Dimensions x x 75 x 22,5 x 102 mm Dimension drawing Accessories can be found in chapter

25 MCVO-Relay modules RME Input relay RME Input relay ±A1 ± ±A ± A ±1 ± Ordering data Art.-No. Art.-No. Input voltage 1 relay; 4 C/O contacts 2 relay; each 1 C/O contact 24 V DC V DC 0 V AC 230 V AC 502 echnical data Input (coil) Input voltage/current 24 V DC ±10 %/20 ma 24 V DC ±10 %/20 ma 230 V AC +10 % -15 %/8,5 ma Status indicator LED yellow LED yellow echnical data Output (contact) Max. switched voltage 250 V AC/DC 5 V AC/150 V DC Max. switched current 2 A 1 A Min. load current 1 ma 1 ma Max. power rating (voltage dependent) 5 VA/60 W 60 VA/30 W Contact material Ag hv Pd Ni-Au Rh Energize/release/contact bounce time 10/10/1 ms 10/10/1 ms Mech./elect. life 1 x 10 8 /load dependent 15 z est insulation voltage 1,5 kv AC emperature range C Mounting method DIN-rail mounting to EN or EN Dimensions x x 75 x 22,5 x 102 mm Dimension drawing Accessories can be found in chapter

26 MCVO-Relay modules with positive displacement contact RM Output relay with positive displacement contact RM Output relay with positive displacement contact ±A1 ± ± ±A Ordering data Art.-No. Art.-No. Input voltage 1 relay; 2 N/O contacts/2 N/C contacts 1 relay; 3 N/O contacts/1 N/C contact 24 V DC V DC 0 V AC 230 V AC echnical data Input (coil) Input voltage/current 24 V DC ±10 %/50 ma Status indicator LED red echnical data Output (contact) Max. switched voltage 250 V AC/80 V DC Max. switched current 4 A Min. load current 100 ma Max. power rating (voltage dependent) 1000 VA/50 W Contact material Ag hv; Ag Sn O 2 Energize/release/contact bounce time 15/15/2 ms Mech./elect. life 1 x 10 6 /load dependent 1 z est insulation voltage 2,5 kv AC emperature range C Mounting method DIN-rail mounting to EN or EN Dimensions x x 75 x 22,5 x 102 mm Dimension drawing Accessories can be found in chapter

27 MIRO imer module erminal relay with timer function MR 6,2 mm imer switch on delay function MR 6,2 mm imer switch off delay function t t Ordering data Art.-No. Art.-No. ime ranges spring clamp/screw terminals spring clamp/screw terminals 0,1 10 sec sec echnical data Input (coil) Input voltage/current A 24 V DC/ %/20 ma Control voltage/current 24 V DC/ %/ 5 ma echnical data Output (contact) Switching element relay Max. switched voltage 250 V AC/DC Max. switched current 6 A (see table) Min. load current 10 ma/ V DC Max. power rating (voltage dependent) 1500 VA/0 W Contact material Ag Sn O 2 Energize/release/contact bounce time 10/15/1,5 ms Switch on delay Mech./elect. life 2 x 10 7 /load dependent 10 z est insulation voltage 4 kv/ac; safe separation to VDE 0106/VDE 0160 emperature range C Mounting method DIN-rail mounting to EN Dimensions x x 90 x 6,2 x 65 mm Function diagram - 18 Out t 1 Out t Accessories Dimension drawing Load limit curve De-rating curve Switching capabilites Label plate Art.-No I (A) to EN Wire chain 16-pole Art.-No Only for 6,2 mm modules ridging link max. 2 A Art.-No ridging comb 10-pole red Art. No ridging comb 10-pole blue Art.-No U s (V DC) ,1 0, I s (A) ( C) o order screw terminal option omit the 66 from the part number. When switching inductive loads, we suggest using a suppression module to reduce interference and improve the relay lifespan. Accessories can be found in chapter AC AC 15 DC 24 V 6 A 3 A 1 A 0 V 6 A 3 A 0,2 A 230 V 6 A 3 A 0,1 A

28 MIRO imer module Solid state relais with switch on delay MR 6,2 mm riac output switch on delay function t 4 (L) (N) Ordering data Art.-No. ime ranges spring clamp/screw terminals 0,5 sec echnical data Input (coil) Input voltage/current A Control voltage/current 230 V AC/ % echnical data Output (contact) Switching element triac Max. switched voltage 250 V AC/DC Max. switched current 1 A (see table) Min. load current 100 ma Max. power rating (voltage dependent) 250 VA Switch on delay 0,5 sec % 0,5 z emperature range C Mounting method DIN-rail mounting to EN Dimensions x x 78 x 6,2 x 65 mm Function diagram 4(L) 3 t Accessories Dimension drawing Derating curve Label plate Art.-No I (A) Wire chain 16-pole Art.-No ,0 A 0,8 A Only for 6,2 mm modules ridging link max. 2 A Art.-No ridging comb 10-pole red Art. No ( C) ridging comb 10-pole blue Art.-No o order screw terminal option omit the 66 from the part number. When switching inductive loads, we suggest using a suppression module to reduce interference and improve the relay lifespan. Accessories can be found in chapter

29 MIRO imer module erminal relay with timer function MR 6,2 mm imer Multifunction MR,4 mm imer Multifunction 1 t 17 A1 t P Ordering data Art.-No. Art.-No. ime ranges spring clamp/screw terminals spring clamp terminals 0,1 300 sec 1) echnical data Input (coil) Input voltage/current A 24 V DC/ %/20 ma 24 V AC/DC; 230 V AC / 20 ma Control voltage/current 24 V DC/ %/ 5 ma V AC/DC / 5 ma echnical data Output (contact) Switching element relay Max. switched voltage 250 V AC/DC Max. switched current 6 A (see table) Min. load current 10 ma/ V DC Max. power rating (voltage dependent) 1500 VA/0 W Contact material Ag Sn O 2 Energize/release/contact bounce time 10/15/1,5 ms Mech./elect. life 2 x 10 7 /load dependent 10 z est insulation voltage 4 kv/ac; safe separation to VDE 0106/VDE 0160 Air and creepage distance 6/8 mm emperature range C Mounting method DIN-rail mounting to EN Dimensions x x 90 x 6,2 x 65 mm 90 x,4 x 65 mm Function diagram DIP-switches time function t ,1-1,2 s on off on on on Switch on delay 0,4-5 s off on on off on One shot 3,5-40 s on on off on on linker Pause starting s off off off off on linker Impulse starting 1 off off off Switch off delay Accessories Dimension drawing Load limit curve De-rating curve Switching capabilites Label plate Art.-No I (A) to EN Wire chain 16-pole Art.-No Only for 6,2 mm modules ridging link max. 2 A Art.-No ridging comb 10-pole red Art. No ridging comb 10-pole blue Art.-No U s (V DC) ,1 0, I s (A) ( C) o order screw terminal option omit the 66 from the part number. When switching inductive loads, we suggest using a suppression module to reduce interference and improve the relay lifespan. Accessories can be found in chapter AC AC 15 DC 24 V 6 A 3 A 1 A 0 V 6 A 3 A 0,2 A 230 V 6 A 3 A 0,1 A

30 Relay socket modules MKS-K Sockets for cradle relays with wiring method via screw terminals. Integrated LED and suppression. Snaps onto DIN-rail to EN (35 mm). MKS-J Sockets for industrial relay with wiring method via screw terminals. Integrated LED and suppression. Snaps onto DIN-rail to EN (35 mm). Page IR 4 Sockets for industrial relay with wiring method via screw terminals. Snaps onto DIN-rail to EN (35 mm). Versions in IP 40 and IP 20. Page R Sockets for 3 or 8 card relays with wiring method via screw terminals. Snaps onto DIN-rail to EN (35 mm). Page RP Sockets for universal relays in 8- and -pole versions with wiring method via screw terminals. Snaps onto DIN-rail to EN (35 mm). Page MR Socket for plug-in relays with 1 or 2 C/O. Snaps onto DIN-rail to EN (35 mm). Suitable for all plug-in relays and can be fitted with a suppressor Page Page

31 Relay socket modules Sockets for cradle relays MKS-K 4 C/O contacts A Ordering data Art.-No. Art.-No. Coil voltage Suppression 24 V DC LED + Diode V AC LED + RC V AC/DC No suppression echnical data Relay socket for cradle relays Max. switched voltage 5 V AC/150 V DC Max. switched current 2 A Wiring method screw terminals max. 4 mm 2 est-insulation voltage 2,5 kv AC Mounting method DIN-rail mounting to EN Dimensions x x 85 x 45 x 64 mm Dimension drawing Accessories Art.-No. Plug-in relays 24 V DC 622 Plug-in relays 230 V AC 640 olding clip 24 V 628 olding clip 230 V 641 Accessories can be found in chapter

32 Relay socket modules Sockets for industrial relays MKS-J 4 C/O contacts Ordering data Art.-No. Art.-No. Coil voltage Suppression 24 V DC LED + Diode V AC LED + RC V AC/DC No suppression echnical data Relay socket for industrial relays Max. switched voltage 250 V AC/0 V DC Max. switched current 3 A Wiring method screw terminals max. 4 mm 2 est-insulation voltage 2,5 kv AC Mounting method DIN-rail mounting to EN Dimensions x x 85 x 45 x 64 mm Dimension drawing A Accessories Art.-No. Plug-in relays 24 V DC 602 Plug-in relays 230 V AC 601 olding clip 24 V 606 olding clip 230 V 606 Accessories can be found in chapter

33 Relay socket modules Sockets for industrial relays with 4 C/O contacts IR Ordering data Input voltage Suppression Art.-No. 230 V AC/DC No suppression 600 echnical data Relay socket for industrial relays suppressor + LED + label plate Max. switched voltage 250 V AC/0 V DC Max. switched current 5 A Wiring method screw terminals Mounting method DIN-rail mounting to EN Proofing IP 40 Dimension drawing Accessories Art.-No. Plug-in relays 24 V DC 602 Plug-in relays 230 V AC 601 olding clip 601 Label plate 602 Suppression module + LED (green) 6 24 V AC/DC V AC/DC 604 Accessories can be found in chapter

34 Relay socket modules Sockets for card relays R Sockets with 3 relay mounts R Sockets with 8 relay mounts A A Ordering data Art.-No. Art.-No. Input voltage Suppression 3 relay socket 8 relay socket 24 V DC LED + Diode echnical data Relay socket 3 relay sockets 8 relay sockets Max. switched voltage 250 V AC/DC 250 V AC/DC Max. switched current 5 A 5 A Wiring method screw terminals, max. 4 mm 2 screw terminals, max. 4 mm 2 est-insulation voltage input output 4,0 kv AC 4,0 kv AC Mounting method DIN-rail mounting to EN DIN-rail mounting to EN Dimensions x x 76 x 45 x 70 mm ( with plugged relays) 76 x 5 x 70 mm ( with plugged relays) Dimension drawing Accessories Art.-No. Plug-in relays 24 V DC 610 olding clip supplied Accessories can be found in chapter

Output of three-phase motors at 50 Hz and 400 V

Output of three-phase motors at 50 Hz and 400 V RT0, RH Coupling Relays (Interfaces) Description DC operation IEC 0 947 and EN 0 947 (VDE 00) The RT0 coupling relays for switching motors and RH for auxiliary circuits are laid out to the special requirements

More information

316 PHOENIX CONTACT. RIF-1 for miniature and solid-state relays Page 334. RIF-2 for industrial relays Page 342. RIF-3 for octal relays Page 346

316 PHOENIX CONTACT. RIF-1 for miniature and solid-state relays Page 334. RIF-2 for industrial relays Page 342. RIF-3 for octal relays Page 346 314 PHOENIX CONTACT PHOENIX CONTACT 315 RIF-0 for miniature and solid-state relays Page 328 RIF-1 for miniature and solid-state relays Page 334 RIF-2 for industrial relays Page 342 RIF-3 for octal relays

More information

relais A mark Relay modules

relais A mark Relay modules Relay modules relais Introduction to relay technology Modular DIN rail mounted relays Plug-in DIN rail mounted relays Multiple chassis mounted relays Timer relays The relay modules offer features such

More information

IDEC RJ22 Series Slim Power Relays (Bifurcated Contacts)

IDEC RJ22 Series Slim Power Relays (Bifurcated Contacts) IDEC RJ22 Series Slim Relays (Bifurcated Contacts) Phone: 00.94.042 - Fax:.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com RJ Series Slim Relay Plug-in Terminal (Bifurcated Contacts) High contact

More information

Relays & Sockets. RF1V Force Guided Relays/SF1V Relay Sockets. Certification Organization/ File Number. UL/c-UL File No.

Relays & Sockets. RF1V Force Guided Relays/SF1V Relay Sockets. Certification Organization/ File Number. UL/c-UL File No. RFV Key features: Compact and EN compliant RFV force guided relays Force guided contact mechanism (EN00 Type A TÜV approved) Contact configuration -pole (NO-NC, 3NO-NC) 6-pole (NO-NC, NO-NC, 3NO-3NC) Built-in

More information

60 Series - General purpose relays 6-10 A. Features Plug-in mount 10 A General purpose relay

60 Series - General purpose relays 6-10 A. Features Plug-in mount 10 A General purpose relay Series - General purpose relays - 0 A Features Plug-in mount 0 A General purpose relay.. & pole changeover contacts Cadmium Free contacts (preferred version) AC coils & DC coils UL Listed (certain relay/socket

More information

48 SERIES. Relay interface modules 8 A CO forcibly guided contacts relay interface modules,15.8 mm wide Type 48.12

48 SERIES. Relay interface modules 8 A CO forcibly guided contacts relay interface modules,15.8 mm wide Type 48.12 48 Relay interface modules 8 A 48 2 CO forcibly guided contacts relay interface modules,15.8 mm wide Type 48.12 2 CO 8 A s Relay with forcibly guided contacts according to EN 50205 Type 35 mm rail (EN

More information

2 Pole CO, 8 A Plug-in 2 CO (DPDT) 1 CO (SPDT) 8/15 16/25* 250/ /400 2,000 4, /0.5/ /0.5/ (5/5) 300 (10/5)

2 Pole CO, 8 A Plug-in 2 CO (DPDT) 1 CO (SPDT) 8/15 16/25* 250/ /400 2,000 4, /0.5/ /0.5/ (5/5) 300 (10/5) 46 Series - Relays for railway applications 8-16 A 46 SERIES Features Plug-in power relays: 8 A, 2 pole 16 A, 1 pole Complies with EN 45545-2:2013 (protection against fire of materials), EN 61373 (resistance

More information

PLC INTERFACE With Leakage Current and Interference Voltage Suppression

PLC INTERFACE With Leakage Current and Interference Voltage Suppression PLC INTERFACE With Leakage Current and Interference Voltage Suppression PLC- SO46 1. PLC INTERFACE, the super thin, plug-in, and flexible modular interface system with a user-friendly jumper system, now

More information

Electronic Circuit Breaker ESS1 for System SVS1

Electronic Circuit Breaker ESS1 for System SVS1 Electronic Circuit Breaker for System SVS Description The electronic circuit breaker is designed to ensure selective disconnection of individual s in industrial systems which are powered by a DC 24 V switch

More information

40 Series - Miniature P.C.B. Relays A

40 Series - Miniature P.C.B. Relays A ..4..4..4 40 Series - Miniature P.C.B. Relays 8-0 - 6 A - P.C.B. or plug-in mount - AC, DC, sensitive DC or single bistable coil versions available - 8 mm, 6 kv (./0 µs) between coil and contacts - Ambient

More information

Measuring and monitoring relays CM-SRS.1 Current monitoring relays, single-phase AC/DC

Measuring and monitoring relays CM-SRS.1 Current monitoring relays, single-phase AC/DC 2CDC 251 244 F0t05 Characteristics Monitoring of DC and AC currents: RMS measuring principle One device includes 3 measuring ranges Over- or undercurrent monitoring configurable Hysteresis adjustable from

More information

58 SERIES. Relay interface modules 7-10 A 58.P3 58.P4

58 SERIES. Relay interface modules 7-10 A 58.P3 58.P4 58 58 3 & 4 CO relay interface modules, 31 mm wide with Push-in terminals Ideal interface for PLC and electronic systems 58.P3 58.P4 Type 58.P3 3 CO 10 A Push-in terminals Type 58.P4 4 CO 7 A Push-in terminals

More information

48 Series - Relay interface modules A. Features

48 Series - Relay interface modules A. Features Series - Relay interface modules 8-0 - 6 A Features & Pole relay interface modules, 5.8 mm wide. Ideal interface for PLC and electronic systems.3 - Pole 0 A.5 - Pole 8 A.6 - Pole 6 A coils or sensitive

More information

DATASHEET - ETR4-51-A. Delivery program. Technical data General. Timing relay, star-delta, 50 ms, 1W, 3-60s, VAC/DC

DATASHEET - ETR4-51-A. Delivery program. Technical data General. Timing relay, star-delta, 50 ms, 1W, 3-60s, VAC/DC DATASHEET - ETR4-51-A Timing relay, star-delta, 50 ms, 1W, 3-60s, 24-240VAC/DC Part no. ETR4-51-A Catalog No. 031884 Eaton Catalog No. XTTR6A60S51B EL-Nummer 0004133308 (Norway) Delivery program Product

More information

RJ Series Slim Power Relays

RJ Series Slim Power Relays RJ Series RJ Series Slim Relays Circuit Breakers Terminal Blocks Timers Display Lights Switches & Pilot Lights Compact and rugged power relays. Large switching capacity. Compact housing only.7-mm wide.

More information

SIGMA Terminal components

SIGMA Terminal components SIGMA Terminal components Optocouplers Content Terminal components Description, Certifications, Authorizations... 151 Ordering details R1000 / R2000 / R 1500... 152 Ordering details - Series RT, PT, MT...

More information

Industrial Controls. Catalog IC SIRIUS. Answers for industry.

Industrial Controls. Catalog IC SIRIUS. Answers for industry. Industrial Controls Catalog IC 10 2012 SIRIUS Answers for industry. Contactor Relays Siemens AG 2012 Overview Standards IEC 60947-1, EN 60947-1, IEC 60947--1, EN 60947--1 The 3TH42 and 3TH43 contactor

More information

Control relays. K mini-control relays. 2 or 4 for CA2-K and CA3-K: 2 for CA4-K. Conforming to VDE 0110 group C V 750

Control relays. K mini-control relays. 2 or 4 for CA2-K and CA3-K: 2 for CA4-K. Conforming to VDE 0110 group C V 750 Characteristics Contact characteristics of mini-control relays and instantaneous contact blocks Number of contacts On CAp-K 4 On L-K 2 or 4 for C-K and CA3-K: 2 for CA4-K Rated operational voltage (Ue)

More information

CONTA-ELECTRONICS. Relay systems

CONTA-ELECTRONICS. Relay systems CONTA-ELECTRONICS Relay technology continues to play a large role in the reliability of industrial control and automation solutions. Because of their thin design, relay couplers are suitable for use in

More information

Monitoring Relays 1-Phase True RMS AC/DC Over and Under Current Types DIC01, PIC01

Monitoring Relays 1-Phase True RMS AC/DC Over and Under Current Types DIC01, PIC01 Monitoring Relays -Phase rue RMS AC/DC Over and nder Current ypes DC0, PC0 DC0 PC0 RMS AC/DC over + under, over+over, under+under current and voltage monitoring relays DC process signal plus/minus monitoring

More information

RELOG. All-or-nothing Relay

RELOG. All-or-nothing Relay RELOG All-or-nothing Relay Table of Content Page RELOG a system with contact components used in control engineering 3 Survey of the 'All-or-nothing relays' device program included in the RELOG system 3

More information

Monitoring Relays 1-Phase True RMS AC/DC Over and Under Current Types DIC01, PIC01

Monitoring Relays 1-Phase True RMS AC/DC Over and Under Current Types DIC01, PIC01 Monitoring Relays -Phase rue RMS AC/DC Over and nder Current ypes, PC0 PC0 RMS AC/DC over + under, over+over, under+under current and voltage monitoring relays DC process signal plus/minus monitoring relay

More information

Electronic Circuit Breaker ESS1 for System SVS1

Electronic Circuit Breaker ESS1 for System SVS1 Electronic Circuit Breaker for System SVS Description The electronic circuit breaker is designed to ensure selective disconnection of individual s in industrial systems which are powered by a DC 24 V switch

More information

38 Series - Relay interface modules A

38 Series - Relay interface modules A 38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 A Common features Instant ejection of relay by plastic retaining clip Integral coil indication and protection circuit EMR Electromechanical Relays

More information

38 Series - Relay interface modules A

38 Series - Relay interface modules A 38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 A Common features Instant ejection of relay by plastic retaining clip Integral coil indication and protection circuit 6.2 mm wide EMR - DC, AC or AC/DC

More information

DATASHEET - ETR4-70-A. Delivery program. Timing relay, 2W, 0.05s-100h, multi-function, VAC/DC, potentiometer connection

DATASHEET - ETR4-70-A. Delivery program. Timing relay, 2W, 0.05s-100h, multi-function, VAC/DC, potentiometer connection DATASHEET - ETR4-70-A Delivery program Timing relay, 2W, 0.05s-100h, multi-function, 24-240VAC/DC, potentiometer connection Part no. ETR4-70-A Catalog No. 031888 Eaton Catalog No. XTTR6A100H70B EL-Nummer

More information

62 Series - Power relays 16 A. Features / /

62 Series - Power relays 16 A. Features / / 6 Series - Power relays 6 A Features 6. / 6.3 6.-0300 / 6.3-0300 Printed circuit mount 6 A Power relay & 3 Pole changeover contacts or NO ( 3 mm contact gap) AC coils & DC coils Reinforced insulation between

More information

3RH1 contactor relays, 4- and 8-pole

3RH1 contactor relays, 4- and 8-pole Siemens AG 2010 RH, TH Contactor Relays RH1 contactor relays, 4- and 8-pole Overview AC and DC operation IEC 60947, EN 60947. The RH1 contactor relays are suitable for use in any climate. They are finger-safe

More information

MasterINTERFACE 39 Series - Relay interface modules

MasterINTERFACE 39 Series - Relay interface modules Common features Space saving 6.2 mm wide Connections for 16-way jumper link Integral coil indication and protection circuit Secure retention and easy ejection by plastic clip Dual screw head (blade+cross)

More information

MasterINTERFACE 39 Series - Relay interface modules

MasterINTERFACE 39 Series - Relay interface modules MasterINTERFACE 39 Series - Relay interface modules Common features Space saving 6.2 mm wide Connections for 16-way jumper link Integral coil indication and protection circuit Secure retention and easy

More information

Electronic timer CT-AWS Impulse-OFF with 1 c/o contact Data sheet

Electronic timer CT-AWS Impulse-OFF with 1 c/o contact Data sheet 2CDC 251 121 F0004 1 5 2 4 3 6 Characteristics Single-function impulse-off timer One device includes 10 time ranges, from 0.05 s to 300 h, for the adjustment of the pulse time Remote potentiometer connection

More information

Controls Contactors and Contactor Assemblies Special Applications

Controls Contactors and Contactor Assemblies Special Applications Controls Contactors and Contactor Assemblies Special Applications Price groups 1B, 1H /2 Introduction More information can be found on the Internet: see the opening information, page 13 - Contactors for

More information

No-wear isolation of potentials in terminal block design

No-wear isolation of potentials in terminal block design TERMOPTO Overview No-wear isolation of potentials in terminal block design Space saving solid-state relay with PUSH IN connection technology The TERMOPTO opto modules are characterised by a particularly

More information

Electronic timer CT-TGD.22

Electronic timer CT-TGD.22 2CDC 251 097 F0t06 a Rotary switch for the preselection of the time range of the ON time b Potentiometer with direct reading scale for the fine adjustment of the ON time c Rotary switch for the preselection

More information

Type CP-S, CP-C & CP-A Switch mode

Type CP-S, CP-C & CP-A Switch mode Switch mode power CP-S, CP-C & CP-A Switch mode Characteristics CP-S and CP-C range Output current 5 A, 10 A and 20 A Integrated power reserve of up to 50 % 5 A and 10 A devices with pluggable connecting

More information

Switching Devices Contactors and Contactor Assemblies for Switching Motors

Switching Devices Contactors and Contactor Assemblies for Switching Motors Switching Devices Contactors and Contactor Assemblies for Switching Motors groups 41B, 41H / Introduction Power contactors for switching motors /5 General data /11 SIRIUS RT10 contactors, -pole,... 50

More information

1-Phase True RMS AC/DC Over and Under Current Types DIC01, PIC01

1-Phase True RMS AC/DC Over and Under Current Types DIC01, PIC01 Monitoring Relays -Phase True RMS AC/DC Over and Under Current Types DIC0, PIC0 DIC0 PIC0 TRMS AC/DC over + under, over+over, under+under current and voltage monitoring relays DC process signal plus/minus

More information

Electronic timer CT-SDS.22 Star-delta change-over with 2 n/o contacts Data sheet

Electronic timer CT-SDS.22 Star-delta change-over with 2 n/o contacts Data sheet CDC 0 F0t07 Features Rated control supply voltage -8 V DC, -0 V AC Single-function timer with star-delta change-over One device includes 7 time ranges (0.0 s - 0 min) n/o contacts LEDs for status indication

More information

Electronic timer CT-ERS ON-delayed with 2 c/o contacts Data sheet

Electronic timer CT-ERS ON-delayed with 2 c/o contacts Data sheet 1SVR 430 103 F0200 CT-ERS 1 7 2 6 5 4 8 3 1 10 selectable time ranges, from 0.05 s to 300 h 2 Potentiometer with direct reading scale for the fine adjustment of the time delay 3 Sliding switch to set the

More information

Miniature Power Relay MSR

Miniature Power Relay MSR V23061 PCB relay for DC voltage, neutral, monostable Features Used as a switching element for electrical separation between low-power control circuits and power load circuits With 8 mm clearance and creepage

More information

10/2 Product overview. 10/3 4AC3 0, 4AC3 1 bell transformers. 10/5 4AC AC3 6 transformers for permanent loads. 10/8 4AC2 4 power supply units

10/2 Product overview. 10/3 4AC3 0, 4AC3 1 bell transformers. 10/5 4AC AC3 6 transformers for permanent loads. 10/8 4AC2 4 power supply units BETA Switching Transformers, Bells and Socket Outlets /2 Product overview /3 4AC3 0, 4AC3 1 bell transformers /5 4AC3 4... 4AC3 transformers for permanent loads /8 4AC2 4 power supply units / 7LQ2 2 bells

More information

via cable Route of signal interferences Shielding against radiation

via cable Route of signal interferences Shielding against radiation 1. Introduction In the vicinity of electronics and control systems, there is often high powered equipment and cabling. In these situations it is possible that electronic circuits can be affected by these

More information

02/11/2015

02/11/2015 35 mm - 1 Relay 8A OUR3 Part number 88867103 Multi-function or mono-function Multi-range Multi-voltage Relay output 1 or 2 : 8 A - 250 V (10 A UL) LED status indicator Option of connecting an external

More information

Current monitoring relays CM-SRS.2 for single-phase AC/DC currents

Current monitoring relays CM-SRS.2 for single-phase AC/DC currents Data sheet Current monitoring relays CM-SRS.2 for single-phase AC/DC currents For the monitoring of currents in single-phase AC/DC systems, ABB s CM range comprises a wide selection of powerful and compact

More information

38 Series - Relay Interface Modules A

38 Series - Relay Interface Modules A Series - Relay Interface Modules 0.1-2 - 6 A - Relay interface modules for use with PLC systems, mm wide - Sensitive DC coil or AC/DC coil version - Supplied with integral coil - Instant removal of relay

More information

QUINT-PS/ 1AC/24DC/20

QUINT-PS/ 1AC/24DC/20 Primary-switched power supply with SFB technology, 1 AC, output current 20 A INTERFACE Data sheet 103129_en_04 1 Description PHOENIX CONTACT - 02/2010 Features QUINT POWER power supply units Maximum system

More information

Pluggable interface relays CR-U Universal relays

Pluggable interface relays CR-U Universal relays Data sheet Pluggable interface relays CR-U Universal relays Pluggable interface relays are used for electrical isolation, amplification and signal matching between the electronic controlling, e.g. PLC

More information

Power Electronics. POWERSWITCH Semiconductor Contactor BF 9250, BH 9250

Power Electronics. POWERSWITCH Semiconductor Contactor BF 9250, BH 9250 Power Electronics POWERSWITCH Semiconductor Contactor, BH 9250 02342 According to IEC/E 60 947-4-2, IEC/E 60 947-4-3 1-, 2- and 3-pole models Load current up to 50 A For AC load up to 480 V Switching at

More information

Monitoring Relays 3-Phase Active power direction Types DWB03, PWB03

Monitoring Relays 3-Phase Active power direction Types DWB03, PWB03 Monitoring Relays 3-Phase Active power direction ypes DWB03, PWB03 DWB03 PWB03 RMS active power relays for three phase balanced applications Measuring if active power is within set limits Measure their

More information

Mini Contactors. Mini Contactor Relays 4-pole 8 Auxiliary Contact Blocks. Interface Contactor Relays. Mini Contactors 10 Auxiliary Contact Blocks

Mini Contactors. Mini Contactor Relays 4-pole 8 Auxiliary Contact Blocks. Interface Contactor Relays. Mini Contactors 10 Auxiliary Contact Blocks Mini Contactors Mini Contactor Relays 4-pole 8 Auxiliary Contact Blocks Interface Contactor Relays Mini Contactors 10 Auxiliary Contact Blocks Mini Contactors With Fast On Tab Connectors 12 Mini Contactors

More information

Voltage monitoring relays CM-ESS.1 for single-phase AC/DC voltages

Voltage monitoring relays CM-ESS.1 for single-phase AC/DC voltages Data sheet Voltage monitoring relays CM-ESS.1 for single-phase AC/DC voltages For the monitoring of voltages in single-phase AC/DC systems, ABB s CM range comprises a wide selection of powerful and compact

More information

Relay systems. Interface Relay Compact IRC, Multifunction Timing Relay MFR IRC

Relay systems. Interface Relay Compact IRC, Multifunction Timing Relay MFR IRC Interface Relay Compact IRC, Multifunction Timing Relay MFR IRC IRC relay couplers and MFR-IRCP timing relays embody a new strategy for 6.2 mm coupling relays. Our five different relay versions provide

More information

Electronic timer CT-MVS.23 Multifunctional with 2 c/o (SPDT) contacts

Electronic timer CT-MVS.23 Multifunctional with 2 c/o (SPDT) contacts Data sheet Electronic timer CT-MVS.23 Multifunctional with 2 c/o (SPDT) contacts The CT-MVS.22 is a multifunctional electronic timer from the CT-S range. It provides 11 timing functions and 10 time ranges.

More information

38 SERIES. Relay interface modules A. EMR Electromechanical Relays. Common features. SSR Solid State Relays. 6.

38 SERIES. Relay interface modules A. EMR Electromechanical Relays. Common features. SSR Solid State Relays. 6. 38 Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A 38 Common features Instant ejection of relay by plastic retaining clip Integral coil indication and protection circuit 6.2 mm wide EMR - DC, AC or AC/DC

More information

Relay interface modules A

Relay interface modules A 4C SЕRIES Relay interface modules 8-10 - 16 A Escalators Road / tunnel lighting Hoists and cranes Carousel warehouses Control panels Panels for electrical distribution FINDER reserves the right to alter

More information

COMPACT SIZE HIGH PRECISION TIMERS VARIOUS OUTPUT & OPERATION MODE TYPES. UL File No.: E CSA File No.: LR39291

COMPACT SIZE HIGH PRECISION TIMERS VARIOUS OUTPUT & OPERATION MODE TYPES. UL File No.: E CSA File No.: LR39291 COMP SIZE HIGH PRECISI IMERS VARIOUS OUPU & OPERAI MODE YPES SDX (one) SDX imers Features UL File No.: E22222 CSA File No.: LR3929 3 operation modes added for fuller lineup Now, operation modes include

More information

Electronic plugs for valves MSE

Electronic plugs for valves MSE Murrelektronik valve plugs with integrated electronic circuits. Saves time, money and space. Electronics With the Murrelektronik electronic valve plugs, we have made it possible to integrate many different

More information

Electronic timer CT-SDS.22

Electronic timer CT-SDS.22 CDC 0 F0t07 Features Rated control supply voltage 8 V DC, 0 V AC Single function timer with star delta change over One device includes 7 time ranges (0.0 s 0 min) n/o contacts LEDs for status indication

More information

Modular equipment. Presentation, standards. Standard contactors TeSys GC

Modular equipment. Presentation, standards. Standard contactors TeSys GC Presentation, standards Standard contactors TeSys GC Presentation TeSys GC contactors are designed for use in modular panels and enclosures. These contactors feature: b Easy installation v quick clip-on

More information

PHOENIX CONTACT - 06/2008. Features. DANGER OF EXPLOSION! Only remove equipment when it is disconnected and not in the potentially explosive area.

PHOENIX CONTACT - 06/2008. Features. DANGER OF EXPLOSION! Only remove equipment when it is disconnected and not in the potentially explosive area. Primary-switched power supply with SFB technology, 1 AC, output current 20 A INTERFACE Data Sheet 103383_en_00 1 Description PHOENIX CONTACT - 06/2008 Features QUINT POWER power supply units highest system

More information

Relays & Sockets. RF2V 2-Pole Force Guided Relays/SJ Series Relay Sockets. UL/Recogntion File No. E55996 TÜV SÜD. EU Low Voltage Directive

Relays & Sockets. RF2V 2-Pole Force Guided Relays/SJ Series Relay Sockets. UL/Recogntion File No. E55996 TÜV SÜD. EU Low Voltage Directive RFV RFV -Pole Force Guided Relays/SJ Series Relay Sockets Key features: -pole force guided relay to reduce cost and installation space. Force guided contact mechanism (EN00 Type A TÜV approved). Reinforced

More information

22 Series Relays. Technical Data...1. Specifications...2. Model Number Structure - Relays...3. Model Number Selection

22 Series Relays. Technical Data...1. Specifications...2. Model Number Structure - Relays...3. Model Number Selection Relays 22 Technical Data...1 Specifications...2 Model Number Structure - Relays...3 Model Number Selection... 4-5 Electrical Characteristics...6 Accessories...7 Dimensions...8 Instructions...10 Safety

More information

Electronic timer CT-SDD.22

Electronic timer CT-SDD.22 CDC 099 F0t0 a Rotary switch for the preselection of the time range b Potentiometer with direct reading scale for the fine adjustment of the time delay c U: green LED V control supply voltage applied W

More information

PCB relay for DC voltage, polarized, monostable or bistable

PCB relay for DC voltage, polarized, monostable or bistable V23042 PCB relay for DC voltage, polarized, monostable or bistable Features Universally applicable in the most varied circuit functions in the field of telecommunications and small signal technology Versatile

More information

MCU-10. Display. Adjustments. Analogue Output, Measuring. Analogue Output, Setpoint. Standard Process Signal. LED Indication.

MCU-10. Display. Adjustments. Analogue Output, Measuring. Analogue Output, Setpoint. Standard Process Signal. LED Indication. Introduction & Selection Guide INTRODUCTION The Brodersen monitoring relays are high quality products incorporating up-to-date circuit design together with modern, efficient components to ensure a long

More information

Manual triggering of the adaption by pressing the «Adaption» button or with the PC-Tool

Manual triggering of the adaption by pressing the «Adaption» button or with the PC-Tool echnical data sheet SMA--P Multifunctional damper actuator for adjusting air dampers in ventilation and air-conditioning systems for building services installations For air dampers up to approx. m orque

More information

Electronic timer CT-MVS.12 Multifunctional with 1 c/o (SPDT) contact

Electronic timer CT-MVS.12 Multifunctional with 1 c/o (SPDT) contact Data sheet Electronic timer CT-MVS.12 Multifunctional with 1 c/o (SPDT) contact The CT-MVS.12 is a multifunctional electronic timer from the CT-S range and provides 10 timing functions and 10 time ranges.

More information

Current monitoring relays CM-SRS.1 for single-phase AC/DC currents

Current monitoring relays CM-SRS.1 for single-phase AC/DC currents Data sheet Current monitoring relays CM-SRS.1 for single-phase AC/DC currents For the monitoring of currents in single-phase AC/DC systems, ABB s CM range comprises a wide selection of powerful and compact

More information

The power in relays and timers since Catalogue

The power in relays and timers since Catalogue The power in relays and timers since 1954 2012 Catalogue PCB relays Industrial relays Relay interface modules Sockets and accessories Timers Monitoring relays Energy meters Surge protection devices Industrial

More information

Monitoring Relays True RMS 3-Phase, 3-Phase+N, Multifunction Types DPC01, PPC01

Monitoring Relays True RMS 3-Phase, 3-Phase+N, Multifunction Types DPC01, PPC01 Monitoring Relays rue RMS 3-Phase, 3-Phase+, Multifunction ypes DPC01, PPC01 DPC01 Product Description 3-phase or 3-phase+neutral line voltage monitoring relay for phase sequence, phase loss, asymmetry,

More information

Electronic timer CT-MFS.21

Electronic timer CT-MFS.21 2CDC 251 053 F0t07 a Rotary switch for the preselection of the time range b Potentiometer with direct reading scale for the fine adjustment of the time delay c Rotary switch for the preselection of the

More information

Capacitor Switching Contactors

Capacitor Switching Contactors Capacitor Switching D385E51 Technical catalogues and news under: www.benedict.at Motor-Starter Mini- Overload Relays Capacitor Switching Motor-Starters Modular Circuit Breakers M4-32T... up to 32A M4-32R..

More information

Semiconductor contactors, Solid-state relays

Semiconductor contactors, Solid-state relays Semiconductor contactors, Solid-state relays Content Benefits and advantages... 338 Approvals and marks... 338 Semiconductor contactors... 339 Ordering details... 339 R100.xx, single-phase... 339 R300.xx,

More information

ABB 1. Multifunctional three-phase monitoring relays. CM-MPS.11, CM-MPS-21, CM-MPS.31 and CM-MPS.41 Data sheet. Features. Approvals. Marks.

ABB 1. Multifunctional three-phase monitoring relays. CM-MPS.11, CM-MPS-21, CM-MPS.31 and CM-MPS.41 Data sheet. Features. Approvals. Marks. 2CDC 251 048 F0t08 CM-MPS.11 2CDC 251 049 F0t08 CM-MPS.21 2CDC 251 050 F0t08 CM-MPS.31 2CDC 251 051 F0t08 CM-MPS.41 R/T: yellow LED - relay status, timing F1: red LED - fault message F2: red LED - fault

More information

3TX7, 3RS18 Coupling Relays

3TX7, 3RS18 Coupling Relays TX7, RS18 Coupling Relays TX7 Coupling Relays, Narrow Design Relay couplers Siemens AG 2010 Application AC and DC operation EN 60947, EN 60664-1 and EN 50005. In the coupling links in double-decker design,

More information

DZD 92 L. Wiring diagram. Time domains. Function. Dimensional drawing. Indicators. Accessories

DZD 92 L. Wiring diagram. Time domains. Function. Dimensional drawing. Indicators. Accessories DZD 92 L Multi-Function - Multi-domain time relay Mono voltage 8 Functions Setting range 0.05 s to 100 h subdivided into 7 time domains 1 immediate-action and 1 time contact or 2 time contacts (adjustable)

More information

Industrial Controls. SIRIUS 3R_1* in sizes S00/S0 to S12. Catalog Add-On IC 10 AO 2012 SIRIUS. Answers for industry.

Industrial Controls. SIRIUS 3R_1* in sizes S00/S0 to S12. Catalog Add-On IC 10 AO 2012 SIRIUS. Answers for industry. Industrial Controls SIRIUS R_* in sizes S00/S0 to S Catalog Add-On IC 0 AO 0 SIRIUS Answers for industry. Controls Contactors and Contactor Assemblies for Switching Motors Price Groups PG B, H / Introduction

More information

Pluggable interface relays CR-P Pcb relays

Pluggable interface relays CR-P Pcb relays 2CDC 293 034 F0004 1 2 4 3 Features 9 different rated control supply voltages U S : DC versions: 12 V, 24 V, 48 V, 110 V AC versions: 24 V, 48 V, 110 V, 120 V, 230 V Output contacts: 1 c/o (16 A) or 2

More information

PHOENIX CONTACT - 05/2008. DANGER OF EXPLOSION! Remove an item only when it is not connected to power or if it is located in the non-explosive area.

PHOENIX CONTACT - 05/2008. DANGER OF EXPLOSION! Remove an item only when it is not connected to power or if it is located in the non-explosive area. Primary-switched power supply with SFB technology, 1 AC, output current 20 A INTERFACE Data Sheet 103129_en_01 PHOENIX CONTACT - 05/2008 1 Description QUINT POWER power supply units highest system availability

More information

Electronic timer CT-AHS.22 OFF-delayed with 2 c/o (SPDT) contacts

Electronic timer CT-AHS.22 OFF-delayed with 2 c/o (SPDT) contacts Data sheet Electronic timer CT-AHS.22 OFF-delayed with 2 c/o (SPDT) contacts The CT-AHS.22 is an electronic timer from the CT-S range with true OFF-delay and 10 time ranges. All electronic timers from

More information

3.5 mm contact pin pitch 1 Pole 12 A PCB direct or via socket

3.5 mm contact pin pitch 1 Pole 12 A PCB direct or via socket 41 Series - Low profile PCB relays 8-12 - 16 A Features 41.31 41.52 41.61 1 & 2 Pole - Low profile (15.7 mm height) 41.31-1 Pole 12 A (3.5 mm pin pitch) 41.52-2 Pole 8 A (5 mm pin pitch) 41.61-1 Pole 16

More information

CONTA-ELECTRONICS. Converter Units

CONTA-ELECTRONICS. Converter Units CONTA-ELECTRONICS Whether for manufacturing, electrical machine and plant instrumentation, control engineering, power distribution, building automation, or process engineering it is always important to

More information

120/240 Watt AC-DC Front End with PFC W Series Convert Select 120 Convert Select 240

120/240 Watt AC-DC Front End with PFC W Series Convert Select 120 Convert Select 240 Industrial Environment AC-DC Converters >100 Watt W Series 120/240 Watt AC-DC Front End with PFC W Series Convert Select 120 Convert Select 240 Rugged 35 mm DIN-rail snap-fit design 3000 V AC input to

More information

38 Series - Relay interface modules A. Features /

38 Series - Relay interface modules A. Features / Series - Relay interface modules 0.1-2 - 6-8 A Features 1 Pole - 6 A electromechanical relay interface modules, 6.2 mm wide. Ideal interface for PLC and electronic systems Sensitive DC coil or coil versions

More information

22/10/2012

22/10/2012 22.5 mm DIN rail mounting TUR1 Part number 88865105 Multi-function or mono-function Multi-range Multi-voltage Screw or spring terminals LED status indicator Option of connecting an external power supply

More information

QUINT-PS/ 3AC/24DC/10

QUINT-PS/ 3AC/24DC/10 Primary-switched power supply with SFB technology, 3 AC, output current 10 A INTERFACE Data sheet 103131_en_01 1 Description PHOENIX CONTACT - 09/2009 Features QUINT POWER power supply units Maximum system

More information

Interface relays and optocouplers Product group picture

Interface relays and optocouplers Product group picture Interface relays and optocouplers Product group picture /1 ABB Catalog Electronic Products and Relays 2013/2014 2CDC 1 004 C0209 Interface relays and optocouplers Table of contents Interface Relays and

More information

Relays & Sockets RU Series Universal Relays. With Latching or Momentary Lever. Standard (without lever) Key features:

Relays & Sockets RU Series Universal Relays. With Latching or Momentary Lever. Standard (without lever) Key features: RU Series Universal Relays Key features: Full featured universal miniature relays Designed with environment taken into consideration Two terminal styles: plug-in and PCB mount Non-polarized LED indicator

More information

ET M3792_a. DC 6, 12, 15, 20, 24 V AC 12, 24, 42, 230 V Voltage range U N

ET M3792_a. DC 6, 12, 15, 20, 24 V AC 12, 24, 42, 230 V Voltage range U N Control Technique Connecting Module Interface Relay Pluggable HC 09 078 According to DIN EN 18 output contacts with monostable PCB-relay OA 8 Version with bistable PCB-relay OB 9 Contact material with

More information

Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection)

Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection) Data sheet Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection) The temperature monitoring relays CM-TCS monitor overtemperature,

More information

Relays & Sockets. General-purpose electromechanical relays and sockets

Relays & Sockets. General-purpose electromechanical relays and sockets Relays & Sockets General-purpose electromechanical relays and sockets Relays (Selection Guide) Category Slim Power Relay Model RJ RJ PC Board Terminal General SPDT, DPDT: A or A contact RoHS directive

More information

DPDT MY2N-D2 MY2IN-D2 --- (DC only) 4PDT MY4N-D2 MY4IN-D PDT (bifurcated) MY4ZN-D2 MY4ZIN-D2 --- With built-in CR

DPDT MY2N-D2 MY2IN-D2 --- (DC only) 4PDT MY4N-D2 MY4IN-D PDT (bifurcated) MY4ZN-D2 MY4ZIN-D2 --- With built-in CR General-purpose Relay MY New model Versatile and Function-filled Miniature Power Relay for Sequence Control and Power Switching Applications Models with lockable test buttons now available. Many variations

More information

Electronic timer CT-MVS.23 Multifunctional with 2 c/o (SPDT) contacts

Electronic timer CT-MVS.23 Multifunctional with 2 c/o (SPDT) contacts Data sheet Electronic timer CT-MVS.23 Multifunctional with 2 c/o (SPDT) contacts The CT-MVS.23 is a multifunctional electronic timer from the CT-S range. It provides 11 timing functions and 10 time ranges.

More information

Type: DILM80(110V50HZ,120V60HZ) Article No.: Sales text Contactor,37kW/400V,AC operated. Ordering information

Type: DILM80(110V50HZ,120V60HZ) Article No.: Sales text Contactor,37kW/400V,AC operated. Ordering information Type: DILM80(110V50HZ,120V60HZ) Article No.: 239399 Sales text Contactor,37kW/400V,AC operated Ordering information Connection technique Description Description Rated operational current AC 3 380 V 400

More information

Characteristics 5 TeSys k contactors and reversing contactors

Characteristics 5 TeSys k contactors and reversing contactors 90 Characteristics contactors k contactors and reversing contactors Environment characteristics Conforming to standards IEC 60947, NF C 63-110, VDE 0660, BS 424 Product certifications LCp and LPp K06 to

More information

CM-MPS.11, CM-MPS-21, CM-MPS.31 and CM-MPS.41 Data sheet. UL 508, CAN/CSA C22.2 No.14 GL GOST CB scheme CCC

CM-MPS.11, CM-MPS-21, CM-MPS.31 and CM-MPS.41 Data sheet. UL 508, CAN/CSA C22.2 No.14 GL GOST CB scheme CCC 2CDC 251 048 F0t08 CM-MPS.11 2CDC 251 049 F0t08 CM-MPS.21 Features Monitoring of three-phase mains for phase sequence (can be switched off), phase failure, over- and undervoltage as well as phase unbalance

More information

Type: DILM95(230V50HZ,240V60HZ) Article No.: Sales text Contactor,45kW/400V,AC operated. Ordering information

Type: DILM95(230V50HZ,240V60HZ) Article No.: Sales text Contactor,45kW/400V,AC operated. Ordering information Type: DILM95(230V50HZ,240V60HZ) Article No.: 239480 Sales text Contactor,45kW/400V,AC operated Ordering information Connection technique Description Description Rated operational current AC 3 380 V 400

More information

21 VA (l max 20 5 ms) Connection Cable 1 m, 4 x 0.75 mm 2 Functional data Factory settings Variable Setting Torque Inhibiting torque

21 VA (l max 20 5 ms) Connection Cable 1 m, 4 x 0.75 mm 2 Functional data Factory settings Variable Setting Torque Inhibiting torque echnical data sheet GK4A- Communicative SuperCap rotary actuator with emergency setting function and extended functionalities for adjusting air dampers in ventilation and air-conditioning systems for building

More information

ABB NEW. Multifunctional three-phase monitoring relays. CM-MPS.23 and CM-MPS.43 Data sheet. Features J. Approvals. Marks.

ABB NEW. Multifunctional three-phase monitoring relays. CM-MPS.23 and CM-MPS.43 Data sheet. Features J. Approvals. Marks. 2CDC 251 052 F0t08 CM-MPS.23 2CDC 251 053 F0t08 CM-MPS.43 - relay status, timing - fault message - fault message Adjustment of the tripping delay t V Adjustment of the threshold value for overvoltage 6