1 FLOW RATE CONTROLLER WTH ANALOG CONTROL OUTUT AND HGH / LOW ALARMS DATASHEET F120 FLOW RATE CONTROLLER Advantages Robust 67 (NEMA Type4X) field enclosure. t is so rugged, you can even stand on it! ntrinsically Safe available ATEX and ECEx approval for gas and dust applications. rogramming can be done by your own crew, with the sensible menudriven structure, saving cost and irritation. Know one, know them all! Very diverse mounting possibilities: walls, pipes, panels or directly onto outdoor sensors! Features Controls the desired volume or mass flow. Displays flow rate, alarms, setpoint and total. Large 17mm (0.67") digits. Safety mode input to place the controller in a safe predefined position. Two alarm values can be entered in %: low and high flow rate alarm. Bumpless switching between 2 operation modes: Hand and Auto. Explosion/flame proof available. Full Modbus communication RS232/485/TTL. Loop or battery powered, 8 24V AC / DC or V AC power supply. LED backlight option. 1 output (0)4 20mA / 0 10V DC control output e.g. to control a valve. Two alarm outputs for low and high flow rate alarm (not available with analog input). input Flow Ability to process all types of flowmeter signals: Reedswitch, NAMUR, NN/N pulse, Sine wave (coil), Active pulse signals, (0)4 20mA. Remote control Safety mode input. External reset / clear lock. Applications The FSeries is your first and safest choice for field mount indicators in safe and hazardous area applications. Especially in harsh weather conditions like rain, snow, salty atmospheres and temperatures between 40 C up to 80 C (40 F up to 176 F). The F120 is designed flow rate control applications; such as chemical processing, plastic manufacturing and the aggregates and cement industry. For DN panel mount indicators, check our DSeries.

2 General information ntroduction The F120 is part of the Fluidwell process controller family and is the alternative for local control loops. The single loop flow controller accepts most pulse inputs from flowmeters and has a 4 20mA output for controlling a pump or valve. Operational There are two operation modes: Hand: the control output can be manually changed, there is no loop connection. Auto: the setpoint can be set and/or changed, corresponding with the process value of flow. Display The display has large 17mm segments which show flow rate, setpoint, alarms and total (resettable). Onscreen engineering units are easily configured from a comprehensive menu. Configuration All configuration settings are accessed via a simple operator menu which can be password protected. Each setting is clearly indicated with an alphanumerical description, which avoids confusing abbreviations and baffling codes. Once familiar with one Fseries product, you will be able to program all models in the series without a manual. All settings are safely stored in EEROM memory in the event of sudden power loss. Analog output signal The flow rate is controlled via the (0)4 20mA or 0 10V DC output signal. The output signal is updated eight times per second. The output signal can be passive, active or isolated where the passive output type will loop power the F120 as well. input The F120 accepts most pulse and analog input signals for volumetric flow or mass flow. The input signal type can be selected by the user in the configuration menu without having to adjust any sensitive mechanical dipswitches or jumpers. The analog input is available with lineair and square root calculation and even as 4 20mA input loop powered. Alarm output Two fixed alarm outputs are available to transmit the flow rate alarm condition, 1 low and 1 high alarm output (not available with analog input). The output signals can be a passive NN, active N or an isolated electromechanical relay. f there is a noflow the alarm output will be disabled. Safety mode The F120 has a safety mode that keeps on transmitting a predefined value as long as the contact is made. After releasing the contact, the former value and function will be reinstalled. Communication All process data and settings can be read and modified manually or through the Modbus communication link (RS232 / RS485). Full Modbus functionality remains available for the ntrinsically Safe version (TTL). Hazardous areas This model has been ATEX and ECEx certified ntrinsically Safe for gas and dust applications, with an allowed ambient temperature of 40 C to 70 C (40 F to 158 F). A flame proof Ex d enclosure with ATEX certification is also available. Enclosures All enclosures are ATEX and ECEx approved. As standard the F120 is supplied in an GR panel mount enclosure, which can be converted to an 67 / NEMA Type4X GR field mount enclosure by the addition of a back case. Most popular is our rugged aluminum field mount enclosure. Overview application F120 Alarm output 1 Remote control: reset total / clearlock Flowmeter input Alarm output 2 Communication Analog Control output 2 F120

3 Dimensions enclosures Aluminum & GR panel mount enclosure Terminal connections Aluminum & GR field / wall mount enclosures CB: RS232 RXD TXD CH: RS485 2 wire A B Y Z CT: TTL ntrinsically Safe FLOWMETER NUT ANALOG OUTUT OWER REQUREMENTS COMMUNCATON DTR 12V C: RS485 4 wire A B RXD TXD DTR 12V ADDTONAL NUT ALARM OUTUT 1 31 mm (1.22") 29 mm (1.14") 120 mm (4.72") 130 mm (5.12") HB & HC enclosures 130 mm (5.12") 115 (4.53") 98 (3.86") panel cutout Ø 7mm (0.27") Ø 7mm (0.27") 120 mm (4.72") Aluminum 30mm 30mm G9 M20 x 1,5 G9 1.18" 1.18" 22,50mm 0.9" HA HL 75 mm (2.95") 60 mm (2.36") HD HE 112 mm (4.40") GR 30mm 30mm 22,50mm ADDTONAL NUT Reset total clear lock 1 /2"NT 1 /2"NT Ø16 Ø20 Ø16 30mm 30mm M16 x 1,5 M20 x 1,5 M16 x 1,5 25mm M20 x 1,5 25mm M20 x 1,5 M20 x 1,5 12mm 12mm 24mm 24mm 36mm 36mm 6 x M12 22,50mm 22,50mm 22,50mm 14mm 17mm 0.9" HM HN HO H HT HF HG HH HJ HK Ø22 ( 7 / 8") 25mm 25mm Ø20 Ø20 12mm 12mm 24mm 24mm Ø12 36mm 36mm 30mm (1.18") 30mm (1.18") Ø22 ( 7 / 8") Ø22 ( 7 / 8") Ø22 ( 7 / 8") 22,50mm (0.9") 22,50mm 14mm 17mm 22,50mm (0.9") ALARM OUTUT 2 00 : coil AA: 4 20mA OA: active 24V DC OA: active 24V DC D: 8 24V AC : reed switch / NN AB: 0 20mA OT: passive trans. OT: passive trans. D: 8 24V DC : N AF: 4 20mA OR: mech. relay OR: mech. relay D X: 16 30V DC = = = = : namur A: 4 20mA F: 24V AC Note: Alarm outputs are not available with analog (A / U) inputs. : active signal A: 4 20mA F: 24V DC A: (0)4 20mA AU: 0 10V M: V AC U U X: 8 30V DC ZB: Backlight: 12 30V DC A X: 8 30V DC Output loop powered A L: 4 20mA B / C: battery powered nternal long life Lithium battery L: input loop powered (terminals GND 1 2 are not available) 1 /2"NT 1.18" 1.18" Flat bottom, no holes available. Display example 90 x 40mm (3.5 x 1.6 ) 0.9" HU 1 /2"NT 1 /2"NT 1 /2"NT 15mm 15mm 16mm 15mm HV 38mm 4 x M20 x 1.5 HZ F120 3

4 Typical wiring diagram F120ACHOTB(X) Typical wiring diagram F120AACHBF TERMNAL CONNECTORS F100 series OUTUT LOO OWERED TERMNAL CONNECTORS F100 series 24V AC / DC OWER SULY Modbus communication type CH: RS485 2 wire Modbus communication type CH: RS485 2 wire B A B A V 1M lowpass V 1M lowpass V 1M lowpass Additional input type B: 3.2V 1M lowpass Additional input type B: Circuit depends on type of signal Flowmeter input type: pulse Analog output type A: passive 4 20mA (loop powered) alarm output V DC Circuit depends on type of signal Analog output type A: passive 4 20mA (loop powered) Flowmeter input type A: (0)4 20mA 8 30V DC alarm output Alarm outputs type OT: (not available with analog input) ower supply type X: 8 30V DC (not used in this example) Main supply ower supply type F: 24V AC / DC 24V AC * For pulse type inputs: V ref : 1.2V/3.0V available. NO power output, available supply : <1mA. Note: using these ref. voltages at max. load, will reduce battery life significantly. * U max sensor is 2V below U supply U max sensor: 8.2V requires 10VDC(8VAC) U supply 12V requires 14VDC(10VAC) U supply 24V requires 26VDC(18VAC) U supply 4 F120

5 Typical wiring diagram F120AAACBBD Typical wiring diagram F120ACBORM TERMNAL CONNECTORS F100 series 24V AC / DC OWER SULY TERMNAL CONNECTORS F100 series V AC OWER SULY TXD RXD DTR 12V Modbus communication type CB: RS232 Z Y B A Modbus communication type C: RS485 4 wire 3.2V 1M lowpass V 1M lowpass V 1M lowpass Additional input type B: 3.2V 1M lowpass Additional input type B: Main supply Alarm outputs type OA: active transistor (not available with analog input) ower supply type D: 8 24V AC / DC Flowmeter input type A: (0)4 20mA Analog output type AA: active 4 20mA 8 24V AC 8 24V DC Main supply Flowmeter input type: pulse Analog output type A: 8 30V DC passive isolated 4 20mA alarm output 1 Switch output type OR: mechanic relay alarm output 2 ower supply type M: V AC N L1 * U max sensor is 2V below U supply U max sensor: 8.2V requires 10VDC(8VAC) U supply 12V requires 14VDC(10VAC) U supply 24V requires 26VDC(18VAC) U supply *Supply voltage: 1.2 / 3.2 / 8.2 / 12 / 24V DC to sensor F120 5

6 Hazardous area applications The F120X has been certified according ATEX and ECEx by DEKRA for use in ntrinsically Safe applications with an ambient temperature of 40 C to 70 C (40 F to 158 F). The ATEX markings for gas and dust applications are: 1 G Ex ia B/C T4 Ga 1 D Ex ia C T100 C Da. The ECEx markings for gas and dust applications are: Ex ia C/B T4 Ga and Ex ia C T100 C Da. t is allowed to connect up to six barriers in B/C applications or one barrier in C applications. Consult the certificate for the maximum input and output values of the circuits. Full functionallity of the F120 remains available, including 8.2V sensor excitation for e.g. Namur sensors (type D) and the Modbus communication type CT. A flame proof enclosure is available as well with rating ATEX 2 GD EEx d B T5. lease contact your supplier for further details. Certificate of conformity KEMA 03ATEX1074 X ECEx DEK X Configuration example B / C and C F120ABOT(X)X Output loop powered unit TERMNAL CONNECTORS F100 series HAZARDOUS AREA SAFE AREA 3.2V 1M lowpass V 1M lowpass Additionalinput type B: Circuit depends on type of signal Ci = 17nF Analog output type A: passive 4 20mA (output loop powered (X)) Flow meter input type: pulse Alarm output 1 ower supply and/or repeater o = max. 100 ma o = max W MTL 5541 e.g. valve controller ower supply or switch interface o = max. 100 ma = max W o MTL 5511 e.g. sounder Alarm output 2 o = max. 100 ma o = max W ower supply or switch interface MTL 5511 e.g. sounder Note: above values are safety values. Consult the technical specification for operational values. * For pulse type inputs: V ref : 1.2V/3.0V available. NO power output, available supply : <1mA. Note: using these ref. voltages at max. load, will reduce battery life significantly. 6 F120

7 Configuration example B / C F120AACTB(X)X Output loop powered unit TERMNAL CONNECTORS F100 series HAZARDOUS AREA SAFE AREA Modbus communication type CT: TTL TXD RXD DTR 12V o = max. 250 ma o = max W.S. Certified solator TTL to: RS232 RS422 TTL : MTL5051 e.g. C 3.2V 1M lowpass V 1M lowpass Additional input type B: Circuit depends on type of signal Flow meter input type: A (0)4 20mA Ci = 17nF Analog output type A X: passive 4 20mA (output loop powered) Uo=max 30V o=max 100mA o=max 750mW o = max. 100 ma o = max W OWER SULY ower supply and/or repeater MTL 5541 e.g. valve controller (Not available with analog input) (Not available with analog input) Note: above values are safety values. Consult the technical specification for operational values. * For pulse type inputs: V ref : 1.2V/3.0V available. NO power output, available supply : <1mA. Note: using these ref. voltages at max. load, will reduce battery life significantly. F120 7

8 Configuration example B / C and C F120ACTBOTDX ower requirement 16 30V DC TERMNAL CONNECTORS F100 series HAZARDOUS AREA SAFE AREA TXD RXD DTR 12V Modbus communication type CT: TTL lease note: communciation type CT is not allowed in C applications. Uo=30V o=250ma o=850mw SOLATOR:.S. Certified solator TTL to RS232 / RS422 / TTL : MTL5051 e.g. C * Note: Communication only allowed when configured as B / C. 3.2V 1M lowpass V 1M lowpass Additional input type B: Circuit depends on type of signal Main supply Ci = 17nF Flow meter input type: pulse TOTAL Co OF ALL CONNECTED AARATUS MAY NOT EXCEED 66nF MNUS 17nF (17nF S USED BY THE ANALOG OUTUT SGNAL TERMNAL 7 8) Analog output type A: passive 4 20mA Alarm output 1 Alarm output 2 ower supply type D: 16 30V DC (please note: D and battery supply (type C) is NOT allowed in C applications). ower supply or switch interface o = max. 100 ma = max W o MTL 5511 e.g. sounder ower supply or switch interface o = max. 100 ma = max W o MTL 5511 e.g. sounder o = max. 100 ma o = max W ower supply Note: above values are safety values. Consult the technical specification for operational values. * Note power supply type D: the supply voltage to pulse sensors is maximum 8.7V (Uo=max 8.7V o=max 25mA o=max 150mW) and to analog sensors as connected to terminal 1 (internally linked). 8 F120

9 Configuration example B / C F120AAFCTBOTDX ower requirement 16 30V DC TERMNAL CONNECTORS F100 series HAZARDOUS AREA SAFE AREA Modbus communication type CT: TTL TXD RXD DTR 12V o = max. 250 ma o = max W.S. Certified solator TTL to: RS232 RS422 TTL : MTL5051 e.g. C 3.2V 1M lowpass V 1M lowpass Additional input type B: Circuit depends on type of signal Main supply Flow meter input type: A (0)4 20mA Ci = 17nF Analog output type AF: passive 4 20mA (output loop powered) (Not available with analog input) (Not available with analog input) Due to analog output type AF, the unit has to be powered with battery type C or with external power supply type D. ower supply type D: 16 30V DC Uo=max 30V o=max 100mA o=max 750mW o = max. 100 ma o = max W o = max. 100 ma o = max W repeater MTL 5541 ower supply e.g. valve controller Note: above values are safety values. Consult the technical specification for operational values. * Note power supply type D: the supply voltage to pulse sensors is maximum 8.7V (Uo=max 8.7V o=max 25mA o=max 150mW) and to analog sensors as connected to terminal 1 (internally linked). REEATER MTL 5541 F120 9

10 Technical specification General Display Type High intensity reflective numeric and alphanumeric LCD, UVresistant. Dimensions 90 x 40mm (3.5 x 1.6 ). Digits Seven 17mm (0.67") and eleven 8mm (0.31") digits. Various symbols and measuring units. Refresh rate User definable: fast, 1sec, 3sec, 15sec, 30sec, off. Option ZB Transflective LCD with white LEDbacklight. Good readings in full sunlight and darkness. Note ZB Only available for safe area applications. Ambient temperature Safe areas 40 C to 80 C (40 F to 176 F). ntrinsically Safe 40 C to 70 C (40 F to 158 F). ower requirements Type A Analog output loop powerd, 8 30V DC. ower consumption max 0.5 Watt. Type B Long life Lithium battery lifetime depends upon settings and configuration up to 5 years. (requires D, L or X) Type C ntrinsically Safe long life lithium battery lifetime depends upon settings and configuration up to 5 years. (requires X and D or X) Type D 8 24V AC / DC ± 10%. ower consumption max. 5 Watt. ntrinsically Safe: 16 30V DC; power consumption max. 1 Watt. Type F 24V AC / DC ± 10%. ower consumption max. 15 Watt. Type L nput loop powered from sensor signal 4 20mA (type A ) requires types A and OT (not Xi). Type M V AC ± 10%. ower consumption max. 15 Watt. Type X 8 30V DC. ower consumption max Watt. Type ZB 12 30V DC ± 10%. ower consumption max. 1.5 Watt. Note B/F/M Not available ntrinsically Safe. Note F/M The total consumption of the sensors and outputs may not exceed 24V. Note For ntrinsically Safe applications, consult the safety values in the certificate. Sensor excitation Type B/C/X 3V DC for pulse signals and 1.2V DC for coil pickup. Note This is not a real sensor supply. Only suitable for sensors with a very low power consumption like coils (sine wave) and reedswitches. Type D 1.2 / 3 / 8.2 / 12 / 24V DC max. 24V DC. Type DX Note Type F / M Umax sensor is 2V below Usupply 1.2 / 3 / 8.2V DC max. 8.2V DC and mains power supply voltage (as connected to terminal 1). n case DX and signal A: the sensor supply voltage is according to the power supply voltage connected to terminal 1. Also terminal 2 offers the same voltage. 1.2 / 3 / 8.2 / 12 / 24V DC max. 24V DC. Terminal connections Type Removable plugin terminal strip. Wire max. 1.5mm 2 and 2.5mm 2. Data protection Type EEROM backup of all settings. Backup of running totals every minute. Data retention at least 10 years. assword Configuration settings can be password protected. Directives & Standards EMC Directive 2014/30/EU, FCC 47 CFR part 15. Low voltage Directive 2014/35/EU RoHS Directive 2011/65/EU ATEX / ECEx Directive 2014/34/EU, EC , EC & NEMA EN & NEMA 250 Enclosure General Window Sealing Control keys olycarbonate window. Silicone. Three industrial microswitch keys. UVresistant silicone keypad. Aluminum wall / field mount enclosures General Diecast aluminum wall/field mount enclosure 67 / NEMA Type4X with 2component UVresistant coating. Dimensions 130 x 120 x 75mm (5.12" x 4.72" x 2.95") W x H x D. Weight 1100 gr. Type HA Cable entry: 2 x G9 and 1 x M20. Type HL Cable entry: 2 x 1 / 2 " NT. Type HM Cable entry: 2 x M16 and 1 x M20. Type HN Cable entry: 1 x M20. Type HO Cable entry: 2 x M20. Type H Cable entry: 6 x M12. Type HT Cable entry: 1 x 1 / 2 " NT. Type HU Cable entry: 3 x 1 / 2 " NT. Type HV Cable entry: 4 x M20. Type HZ Cable entry: no holes. GR wall / field mount enclosures General GR wall/field mount enclosure 67 / NEMA Type4X, UVresistant and flame retardant. Dimensions 130 x 120 x 75mm (5.12" x 4.72" x 2.95") W x H x D. Weight 600 gr. Type HD Cable entry: no holes. Type HE Cable entry: 2 x Ø 16mm and 1 x Ø 20mm. Type HF Cable entry: 1 x Ø 22mm ( 7 / 8 "). Type HG Cable entry: 2 x Ø 20mm. Type HH Cable entry: 6 x Ø 12mm. Type HJ Cable entry: 3 x Ø 22mm ( 7 / 8 "). Type HK Flat bottom, cable entry: no holes. anel mount enclosures Dimensions 130 x 120 x 60mm (5.12" x 4.72" x 2.36") W x H x D. anel cutout 115 x 98mm (4.53" x 3.86") L x H. Type HB Diecast aluminum panel mount enclosure 65 / NEMA Type4X. Weight 600 gr. Type HC GR panel mount enclosure 65 / NEMA Type4X, UVresistant and flame retardant. Weight 450 gr. Hazardous area ntrinsically Safe (Type X) ATEX 1 G Ex ia B/C T4 Ga. certification 1 D Ex ia C T100 C Da. ECEx Ex ia C/B T4 Ga. certification Ex ia C T100 C Da. Ambient Ta 40 C to 70 C (40 F to 158 F). 10 F120

11 Explosion proof (Type XF) ATEX certification 2 G / Ex d B T5 Gb. 2 D / Ex t B T100 C Db. Type XF Dimensions of enclosure: 300 x 250 x 200mm (11.8" x 9.9" x 7.9") L x H x D. Weight Appr. 15kg. Note ECEx available on request. inputs Flowmeter Type Coil / sine wave (H: 20mVpp or LO: 80mVpp sensitivity selectable), NN/N, open collector, reedswitch, Namur, active pulse signals 8 12 and 24V DC. Frequency Minimum 0Hz maximum 7kHz for total and flow rate. Maximum frequency depends on signal type and internal lowpass. E.g. reed switch with lowpass : max. frequency 120Hz. KFactor ,999,999 with variable decimal position. Lowpass Available for all pulse signals. Option ZF coil sensitivity 10mVpp. Type A (0)4 20mA. Analog input signal can be scaled to any desired range within 0 20mA. Type U 0 10V DC. Contact factory. Accuracy Resolution: 14 bit. Error < 0.025mA / ± 0.125% FS. Low level cutoff programmable. Span ,999,999 with variable decimal position. Update time Four times per second. Voltage drop Type A: 2omA. Relationship Linear and square root calculation. Note For signal type A: external power to sensor is required; e.g. type D. Additional inputs Function : Terminal input to activate the predefined safety flow rate value (terminal 15 16). Reset total: Terminal input to reset total remotely. f this terminal input is closed, the clear total function is disabled (terminal 12 13). Type R nternally pulledup switch contact NN. Duration Minimum pulse duration 100msec. outputs Communication option Function Reading display information, reading / writing all configuration settings. rotocol Modbus RTU. Speed baud. Addressing Maximum 255 addresses. Type CB RS232 Type CH RS485 2wire Type C RS485 4wire Type CT TTL ntrinsically Safe. Analog output Function Controlling the flow rate. Accuracy 10 bit. Error < 0.05%. Analog output signal can be scaled to any desired range. Update time Eight times per second. Type AA Active 4 20mA output (requires D, F, M or X). Type AB Active 0 20mA output (requires D, F, M or X). Type AF assive floating 4 20mA output for ntrinsically Safe applications (requires X D). Type A assive galvanically isolated 4 20mA output also available for battery powered models. Type A assive 4 20mA output not isolated. Unit will be loop powered. Type AU Active 0 10V DC output (requires D, F, M or X). Requires min. 12V power supply. Digital outputs Function Low or high flow rate alarm output. Alarm value limits: 0 100%. Type OA Two active 24V DC transistor outputs (N); max. 50mA per output (requires D, F, M or X). Requires min. 24V power supply. Type OR Two electromechanical relay outputs isolated (N.O.) max. switch power 230V AC 0.5A (requires F or M). Type OT Two outputs (NN) not isolated. Max. 50V DC 300mA per output. Note Alarm outputs are not available with analog input. Operational Operator functions Displayed Flow rate setpoint. functions Flowrate. Total. Low flow rate alarm value. High flow rate alarm value. Operation modes: Hand and Auto. Safety mode. Flowrate Digits Units 7 digits. ml, L, m 3, Gallons, kg, Ton, lb, bl, cf, RND, ft 3, scf, Nm 3, Nl, igal no units. Decimals or 3. Time units /sec /min /hr /day. Control arameters Operation mode Hand and Auto. Control action Direct / Reverse. roportional 0.1 to 999,9%. band ntegral time 0.1 to 6,000.0 s or OFF (0.0). Safety output 5.0 to 105.0% (0) = Run / (1) = Safety output. Control output 5.0 to 105.0% for both high and low limits. limiter F120 11

12 Ordering information Standard configuration: F120ACXHCROTXXXZX. Ordering information: F120 _ A _ C _ H _ R O X _ Z _ Flowmeter input signal A (0)4 20mA input. ulse input: coil, npn, pnp, namur, reedswitch. Analog output signal AA Active 4 20mA output requires D, F, M or X. AB Active 0 20mA output requires D, F, M or X. AF.S. floating 4 20mA output requires X D. A solated 4 20mA output. A assive 4 20mA output, loop powered unit. AU Active 0 10V DC output requires D, F, M or X. Communication CB Communication RS232 Modbus RTU. CH Communication RS485 2wire Modbus RTU. C Communication RS485 4wire Modbus RTU. CT ntrinsically Safe TTL Modbus RTU. CX No communication. anel mount enclosures 65 / NEMA Type4X HB Aluminum enclosure. HC GR enclosure. GR field / wall mount enclosures 67 / NEMA Type4X HD Cable entry: no holes. HE Cable entry: 2 x Ø 16mm & 1 x Ø 20mm. HF Cable entry: 1 x Ø 22mm ( 7 /8 ). HG Cable entry: 2 x Ø 20mm. HH Cable entry: 6 x Ø 12mm. HJ Cable entry: 3 x Ø 22mm ( 7 /8 ). HK Flat bottom, cable entry: no holes. Aluminum field / wall mount enclosures 67 / NEMA Type4X HA Cable entry: 2 x G9 1 x M20. HL Cable entry: 2 x 1 /2 NT. HM Cable entry: 2 x M16 1 x M20. HN Cable entry: 1 x M20. HO Cable entry: 2 x M20. H Cable entry: 6 x M12. HT Cable entry: 1 x 1 /2 NT. HU Cable entry: 3 x 1 /2 NT. HV Cable entry: 4 x M20. HZ Cable entry: no holes. Additional input signal R Remote control input to reset total, to lock the clear total button and as safety input. Digital output signals OA Two active transistor outputs requires and D, F, M or X. OR Two mechanical relay outputs requires and F or M. OT Two outputs standard configuration requires. ower requirements D 8 24V AC/DC sensor supply with X: 16 30V DC. F 24V AC/DC sensor supply. L nput loop powered from sensor signal type A requires A and OT (not X). M V AC sensor supply. X Basic power supply 8 30V DC (no real sensor supply). Additional battery supply (optional) B Lithium battery powered requires D, L or X. C Lithium battery powered ntrinsically Safe requires X, and D or X. Hazardous area X ntrinsically Safe, according ATEX and ECEx. XF Ex d enclosure 3 keys according ATEX. XX Safe area only. Other options ZB Backlight. ZF Coil input 10mVpp. ZX No options. The bold marked text contains the standard configuration. Available ntrinsically Safe. Specifications are subject to change without notice. Fluidwell bv.o. Box AA Veghel The Netherlands Telephone: 31 (0) Telefax: 31 (0) displays@fluidwell.com nternet: 12 Copyright: Fluidwell bv 2017 F120DATAENV1727

RATIO CONTROLLER DATASHEET F124 - RATIO CONTROLLER WITH ANALOG CONTROL OUTPUT AND HIGH / LOW ALARMS

RATIO CONTROLLER DATASHEET F124 - RATIO CONTROLLER WITH ANALOG CONTROL OUTPUT AND HIGH / LOW ALARMS RATO CONTROLLER WTH ANALOG CONTROL OUTUT AND HGH / LOW ALARMS DATASHEET F124 RATO CONTROLLER Advantages Robust 67 (NEMA Type4X) field enclosure. t is so rugged, you can even stand on it! ntrinsically Safe

More information

DATASHEET F110 - FLOW RATE INDICATOR / TOTALIZER

DATASHEET F110 - FLOW RATE INDICATOR / TOTALIZER FLOW RATE INDICATOR / TOTALIZER WITH ANALOG AND PULSE SIGNAL OUTPUTS DATASHEET F110 FLOW RATE INDICATOR / TOTALIZER Advantages Robust IP67 (NEMA Type4X) field enclosure. It is so rugged, you can even stand

More information

FLOW RATE INDICATOR / TOTALIZER DATASHEET F112 - FLOW RATE INDICATOR / TOTALIZER

FLOW RATE INDICATOR / TOTALIZER DATASHEET F112 - FLOW RATE INDICATOR / TOTALIZER DATASHEET F112 FLOW RATE INDICATOR / TOTALIZER FLOW RATE INDICATOR / TOTALIZER WITH LINEARIZATION AND ANALOG / PULSE SIGNAL OUTPUTS Advantages Robust IP67 (NEMA Type4X) field enclosure. It is so rugged,

More information

FLOW RATE MONITOR / TOTALIZER

FLOW RATE MONITOR / TOTALIZER FLOW RATE MONITOR / TOTALIZER WITH HIGH / LOW ALARM, ANALOG AND PULSE SIGNAL OUTPUTS DATASHEET F113 FLOW RATE MONITOR Advantages Robust IP67 (NEMA Type4X) field enclosure. It is so rugged, you can even

More information

DATASHEET F110 - FLOW RATE INDICATOR / TOTALIZER

DATASHEET F110 - FLOW RATE INDICATOR / TOTALIZER FLOW RATE INDICATOR / TOTALIZER WITH ANALOG AND PULSE SIGNAL OUTPUTS DATASHEET F110 FLOW RATE INDICATOR / TOTALIZER Advantages Robust IP67 (NEMA4X) field enclosure. It is so rugged, you can even stand

More information

FLOW RATE INDICATOR / TOTALIZER

FLOW RATE INDICATOR / TOTALIZER DATASHEET D012 FLOW RATE INDICATOR / TOTALIZER FLOW RATE INDICATOR / TOTALIZER DISPLAYS FLOW RATE AND TOTAL SIMULTANEOUSLY DSeries advantages Unique, robust IP66, IP67 (NEMA4X) panel mount front enclosure

More information

FLOW RATE MONITOR / TOTALIZER

FLOW RATE MONITOR / TOTALIZER FLOW RATE MONITOR / TOTALIZER WITH HIGH / LOW ALARM, ANALOG AND PULSE SIGNAL OUTPUTS DATASHEET F113 FLOW RATE MONITOR Advantages Robust IP67 (NEMA4X) field enclosure. It is so rugged, you can even stand

More information

TOTALIZER MONITOR DATASHEET F117 - TOTALIZER MONITOR WITH HIGH / LOW TOTALIZER ALARM AND ANALOG SIGNAL OUTPUT

TOTALIZER MONITOR DATASHEET F117 - TOTALIZER MONITOR WITH HIGH / LOW TOTALIZER ALARM AND ANALOG SIGNAL OUTPUT TOTALIZER MONITOR WITH HIGH / LOW TOTALIZER ALARM AND ANALOG SIGNAL OUTPUT DATASHEET F117 TOTALIZER MONITOR Features The desired totalized (preset) quantity can be set by the operator Reset totalizer:

More information

FLOW RATE INDICATOR / TOTALIZER DATASHEET F112 - FLOW RATE INDICATOR / TOTALIZER

FLOW RATE INDICATOR / TOTALIZER DATASHEET F112 - FLOW RATE INDICATOR / TOTALIZER DATASHEET F112 FLOW RATE INDICATOR / TOTALIZER FLOW RATE INDICATOR / TOTALIZER WITH LINEARIZATION AND ANALOG / PULSE SIGNAL OUTPUTS Advantages Robust IP66, IP67 (NEMA4X) field enclosure. It is so rugged,

More information

BATCH CONTROLLER WITH TWO STAGE CONTROL / PULSE OUTPUT DATASHEET F130 - BATCH CONTROLLER

BATCH CONTROLLER WITH TWO STAGE CONTROL / PULSE OUTPUT DATASHEET F130 - BATCH CONTROLLER BATCH CONTROLLER WITH TWO STAGE CONTROL / PULSE OUTPUT DATASHEET F130 BATCH CONTROLLER Features Large display shows preset value and running batch value simultaneously. Selflearning overrun correction.

More information

BATCH CONTROLLER DATASHEET F130 - BATCH CONTROLLER WITH TWO STAGE CONTROL / PULSE OUTPUT

BATCH CONTROLLER DATASHEET F130 - BATCH CONTROLLER WITH TWO STAGE CONTROL / PULSE OUTPUT BATCH CONTROLLER WITH TWO STAGE CONTROL / PULSE OUTPUT DATASHEET F130 BATCH CONTROLLER Advantages Robust IP66, IP67 (NEMA4X) field enclosure. It is so rugged, you can even stand on it! Intrinsically Safe

More information

BATCH CONTROLLER DATASHEET D030 - BATCH CONTROLLER WITH ONE STAGE CONTROL

BATCH CONTROLLER DATASHEET D030 - BATCH CONTROLLER WITH ONE STAGE CONTROL BATCH CONTROLLER WITH ONE STAGE CONTROL DATASHEET D030 BATCH CONTROLLER DSeries advantages Unique, robust IP66, IP67 (NEMA4X) panel mount front enclosure made of die cast aluminum, allowing even big jets

More information

BATCH CONTROLLER WITH TWO STAGE CONTROL / PULSE AND ANALOG OUTPUT IN RELATION TO THE FLOW RATE DATASHEET F131 - BATCH CONTROLLER

BATCH CONTROLLER WITH TWO STAGE CONTROL / PULSE AND ANALOG OUTPUT IN RELATION TO THE FLOW RATE DATASHEET F131 - BATCH CONTROLLER BATCH CONTROLLER WITH TWO STAGE CONTROL / PULSE AND ANALOG OUTPUT IN RELATION TO THE FLOW RATE DATASHEET F131 BATCH CONTROLLER Features Large display shows preset value, running batch value and instantaneous

More information

BATCH CONTROLLER DATASHEET F130 - BATCH CONTROLLER WITH TWO STAGE CONTROL / PULSE OUTPUT

BATCH CONTROLLER DATASHEET F130 - BATCH CONTROLLER WITH TWO STAGE CONTROL / PULSE OUTPUT BATCH CONTROLLER WITH TWO STAGE CONTROL / PULSE OUTPUT DATASHEET F130 BATCH CONTROLLER Advantages Robust IP67 (NEMA Type4X) field enclosure. It is so rugged, you can even stand on it! Intrinsically Safe

More information

FLOW RATE MONITOR / TOTALIZER

FLOW RATE MONITOR / TOTALIZER FLOW RATE MONITOR / TOTALIZER WITH HIGH / LOW ALARM, ANALOG AND PULSE SIGNAL OUTPUTS DATASHEET F113 FLOW RATE MONITOR Features Displays instantaneous flow rate, total and accumulated total. Four alarm

More information

Flow rate Indicator / Totalizer

Flow rate Indicator / Totalizer Datasheet ER100(M) Robust explosion proof indicator Flow rate Indicator / Totalizer with linearization, analog and pulse signal outputs Advantages Save time and gain flexibility with the easytooperate

More information

GENERAL PURPOSE INDICATOR LOOP POWERED WITH VERY LARGE DIGITS DATASHEET F090 - GENERAL PURPOSE INDICATOR

GENERAL PURPOSE INDICATOR LOOP POWERED WITH VERY LARGE DIGITS DATASHEET F090 - GENERAL PURPOSE INDICATOR GENERAL PURPOSE INDICATOR LOOP POWERED WITH VERY LARGE DIGITS DATASHEET F090 - GENERAL PURPOSE INDICATOR Features Universal loop powered indicator. Very large 26mm (1 ) high digits. Displays the actual

More information

FLOW RATE INDICATOR / TOTALIZER DATASHEET F112 - FLOW RATE INDICATOR / TOTALIZER

FLOW RATE INDICATOR / TOTALIZER DATASHEET F112 - FLOW RATE INDICATOR / TOTALIZER DATASHEET F112 FLOW RATE INDICATOR / TOTALIZER FLOW RATE INDICATOR / TOTALIZER WITH LINEARISATION AND ANALOG / PULSE SIGNAL OUTPUTS Features Displays instantaneous flow rate, total and accumulated total.

More information

BATCH CONTROLLER DATASHEET F131 - BATCH CONTROLLER WITH TWO STAGE CONTROL / PULSE AND ANALOG OUTPUT IN RELATION TO THE FLOW RATE

BATCH CONTROLLER DATASHEET F131 - BATCH CONTROLLER WITH TWO STAGE CONTROL / PULSE AND ANALOG OUTPUT IN RELATION TO THE FLOW RATE BATCH CONTROLLER WITH TWO STAGE CONTROL / PULSE AND ANALOG OUTPUT IN RELATION TO THE FLOW RATE DATASHEET F131 BATCH CONTROLLER Advantages Robust IP67 (NEMA Type4X) field enclosure. It is so rugged, you

More information

DATASHEET F010 - FLOW RATE INDICATOR

DATASHEET F010 - FLOW RATE INDICATOR FLOW RATE INDICATOR WITH VERY LARGE DIGITS DATASHEET F010 FLOW RATE INDICATOR Advantages Robust IP66, IP67 (NEMA4X) field enclosure. It is so rugged, you can even stand on it! Intrinsically Safe available

More information

DATASHEET F090 - GENERAL PURPOSE INDICATOR

DATASHEET F090 - GENERAL PURPOSE INDICATOR GENERAL PURPOSE INDICATOR LOOP POWERED WITH VERY LARGE DIGITS DATASHEET F090 - GENERAL PURPOSE INDICATOR Features Universal loop powered indicator. Very large 26mm (1 ) high digits. Displays the actual

More information

Flow Monitor / Totalizer with linearization, high / low alarms, analog and pulse signal outputs and HART Communication

Flow Monitor / Totalizer with linearization, high / low alarms, analog and pulse signal outputs and HART Communication Datasheet E018 Robust explosion proof indicator Reliable Flow Monitor / Totalizer with linearization, high / low alarms, analog and pulse signal outputs and HART Communication Advantages Save time and

More information

F-SERIES FOR. Indicators Totalizers Transmitters Flow computers Batch controllers Monitors. Flow Level Pressure Temperature

F-SERIES FOR. Indicators Totalizers Transmitters Flow computers Batch controllers Monitors. Flow Level Pressure Temperature F-SERIES Indicators Totalizers Transmitters Flow computers Batch controllers Monitors Flow Level Pressure Temperature FOR F - SERIES F - SERIES F - SERIES F - SERIES F - SERIES F - SERIES F - SERIES F

More information

Flowcomputer for Corrected Liquid Volume

Flowcomputer for Corrected Liquid Volume Flowcomputer for Corrected Liquid Volume Owner s Manual Model F126-P Signal input flowmeter - type P: pulse, Namur and coil Signal input pressure - type IA: (0)4-20mA Signal input temperature - type TP:

More information

Electronic Data Devices

Electronic Data Devices Calibration for EDD800 Totalizer Hold PROG/ENTER for 7 seconds Electronic Data Devices Odessa, Texas USA 432-366-8699 rkw@eddevices.com EDD800 CALIBRATION INSTRUCTIONS Setup 1 - Setup 11 - Setup 12 - Setup

More information

Preset counters, electronic

Preset counters, electronic The Codix 716 / 717 can be used universally. These preset pulse, tachometers or preset timers with up to 2 presets can solve a wide variety of control and monitoring tasks in every application. With their

More information

SITRANS F flowmeters SITRANS F US. SONOFLO SONO 3000 transmitter. 4/152 Siemens FI Overview

SITRANS F flowmeters SITRANS F US. SONOFLO SONO 3000 transmitter. 4/152 Siemens FI Overview Overview Design The transmitter is available in different enclosure to fit any demands: IP67 enclosure for compact or wall mounting IP00 as a 19 insert IP65 for wall mounting IP65 enclosure in stainless

More information

Operating Instructions 12/2007 SITRANS F RA 110 ATEX. Intrinsically-safe flowrate indicator/totalizer. flow

Operating Instructions 12/2007 SITRANS F RA 110 ATEX. Intrinsically-safe flowrate indicator/totalizer. flow Operating Instructions 12/2007 Intrinsically-safe flowrate indicator/totalizer flow SITRANS F Flowmeters Intrinsically-safe flowrate indicator/totalizer Operating Instructions (Compact) Introduction Safety

More information

INSTALLATION & OPERATION MANUAL MODEL IT375 FIELD MOUNTED RATE INDICATOR AND TOTALIZER

INSTALLATION & OPERATION MANUAL MODEL IT375 FIELD MOUNTED RATE INDICATOR AND TOTALIZER INSTALLATION & OPERATION MANUAL MODEL IT375 FIELD MOUNTED RATE INDICATOR AND TOTALIZER February 2002 Sponsler, Inc. Model IT375 Contents Pg. 2 CONTENTS 1. Introduction 3 1.1 Model Number Designation 4

More information

BATCHMATE 1500 Batch Control Computer Technical Bulletin

BATCHMATE 1500 Batch Control Computer Technical Bulletin TS-5(C) BATCHMATE 5 Batch Control Computer Technical Bulletin DESCRIPTION The BATCHMATE features an 8 digit.55-in. alphanumeric LED display. The pulse input model will accept up to 2, pulses per second

More information

RHE12. Hazardous Area Coriolis Mass Flow Transmitter. Features. Applications. Benefits

RHE12. Hazardous Area Coriolis Mass Flow Transmitter. Features. Applications. Benefits RHE12 Hazardous Area Coriolis Mass Flow Transmitter Features Field mounting Compact, pressure safe housing ATEX and CSA approvals for installation in hazardous areas 24 VDC power supply Configurable analog

More information

RHE11. Hazardous Area Multifunction Coriolis Flow Transmitter. Features. Applications. Benefits

RHE11. Hazardous Area Multifunction Coriolis Flow Transmitter. Features. Applications. Benefits RHE11 Hazardous Area Multifunction Coriolis Flow Transmitter Features Wall or Pipe Bracket Mount Built in safety barriers allow operation with RHM sensor in hazardous area Selectable Metric and English

More information

FIELD MOUNTED RATE TOTALISER MODEL 202D

FIELD MOUNTED RATE TOTALISER MODEL 202D FIELD MOUNTED RATE TOTALISER MODEL 202D 1 February 1999 CONTENTS 1. Introduction 1 1.1 Model Number Designation 3 1.2 Intrinsic Safety Considerations 4 2. Specification 6 3. Operation 8 3.1 Display 8

More information

Model FLSC-C3-XX. DC Powered Microprocessor Controlled Transmitter

Model FLSC-C3-XX. DC Powered Microprocessor Controlled Transmitter Model FLSC-C3-XX DC Powered Microprocessor Controlled Transmitter CONTENTS. Introduction----------------------------------------------------------------- 2 2. Specifications ---------------------------------------------------------------

More information

MODEL: B6U-B B6-UNIT. [2] LCD DISPLAY 0: Without 1: With

MODEL: B6U-B B6-UNIT. [2] LCD DISPLAY 0: Without 1: With Field-mounted Two-wire Signal Conditioners B6-UNIT 8: TIIS flameproof (CE not available) Confirm selectable combinations of approval and wiring conduit types in the table. 2-WIRE UNIVERSAL TEMPERATURE

More information

ICARUS ELECTRONIC GAS VOLUME CONVERTER

ICARUS ELECTRONIC GAS VOLUME CONVERTER ICARUS ELECTRONIC GAS VOLUME CONVERTER 1. INTRODUCTION 2. TECHNICAL DETAILS ICARUS is an electronic volume converter which, combined with a gas meter, provides the gas measurement in Sm3, calculated at

More information

PR product range - links to order details and block diagrams

PR product range - links to order details and block diagrams PR product range links to order details and block diagrams 2202 2204 2220 2222 2223 2224 2229 2231 2237 2238 2240 2241 2255 2261 2271 2273 2279 2281 2284 2285 2286 2288 2289 2914 3532 4114 4116 4131 5102

More information

Digital I/O Coupler (4-wire) Series 9413/21

Digital I/O Coupler (4-wire) Series 9413/21 Digital /O Coupler (4wire) > The digital /O coupler is used to connect 8 intrinsically safe contacts or proximity initiators and 4 intrinsically safe solenoid valves to a FOUNDATON TM fieldbus H1. > Galvanic

More information

UFM 800 W, C Ultrasonic flowmeter for water and wastewater

UFM 800 W, C Ultrasonic flowmeter for water and wastewater KROHNE 08/2000 7.02343.21.00 GR/PRINTO, C Ultrasonic flowmeter for water and wastewater...with weld-in sensors for metal pipelines...withbuilt-on or built-in sensors for open channels Variable area flowmeters

More information

Design and applications

Design and applications Design and applications The measuring device operates largely independent of viscosity and is suitable for indicating the flow rate of water, acids, alkaline solutions and gases. Every device is calibrated

More information

5-Digit Dual-line explosion-proof pulse input rate/totalizer

5-Digit Dual-line explosion-proof pulse input rate/totalizer 5-Digit Dual-line explosion-proof pulse input rate/totalizer TM RTP OUCH Through-Glass Button Programming protex-rtp Model pd6830 Pulse, Open Collector, NPN, PNP, TTL, Switch Contact, Sine Wave (Coil),

More information

1) What meter do I need in this application?

1) What meter do I need in this application? ELECTRONIC ELECTRONIC Choices 1) What meter do I need in this application? Meter choice is determined by: Level of accuracy required, flowrate, line size, viscosity, fitting type, pressure rating, temperature,

More information

SITRANS F flowmeters SITRANS F US. Transmitter FUS060. Overview

SITRANS F flowmeters SITRANS F US. Transmitter FUS060. Overview Overview Function Displays and keypad Operation of the SITRANS FUS060 transmitter can be carried out using: Keypad and display unit HART communicator PC/laptop and SIMATIC PDM software via HART communication

More information

SITRANS F flowmeters SITRANS F M. Transmitter Transmag 2 with sensor 911/E 4/77. Overview

SITRANS F flowmeters SITRANS F M. Transmitter Transmag 2 with sensor 911/E 4/77. Overview Overview Design The complete flowmeter consists of a flow sensor and an associated transmitter from the Transmag 2 for pulsed alternating field. These are available as remote and compact versions ( 911/E

More information

MJK Expert 700 / 800 / 900 / 1100 / 2100 MJK Expert 1400 / 3400

MJK Expert 700 / 800 / 900 / 1100 / 2100 MJK Expert 1400 / 3400 Data Sheet MJK Expert 700 / 800 / 900 / 1100 / 2100 MJK Expert 1400 / 3400 Submersible Hydrostatic s Rugged and versatile We reserve the right to continuously improve our products and make any change in

More information

control & display PROGRAMMABLE SENSOR CONTROLLER COMPLETE VERSATILITY OF UNDERGROUND SENSOR MANAGEMENT & DATA COMMUNICATIONS

control & display PROGRAMMABLE SENSOR CONTROLLER COMPLETE VERSATILITY OF UNDERGROUND SENSOR MANAGEMENT & DATA COMMUNICATIONS PROGRAMMABLE SENSOR CONTROLLER TX9042 COMPLETE VERSATILITY OF UNDERGROUND SENSOR MANAGEMENT & DATA COMMUNICATIONS ATEX Gas sensors, flow sensors, pressure sensors, vibration monitoring, temperature devices,

More information

Digital flow transmitter for continuous flow measurement

Digital flow transmitter for continuous flow measurement Digital flow transmitter for continuous flow measurement Compact or remote version for DN 06 to 400, PN10 Shows both flow rate and volume (with two totalizers) Automatic-calibration: TEACH-IN Simulation:

More information

STT 3000 Series STT170 SMART TEMPERATURE TRANSMITTER Models STT171, STT173, STT17H, STT17F, STT17C

STT 3000 Series STT170 SMART TEMPERATURE TRANSMITTER Models STT171, STT173, STT17H, STT17F, STT17C STT 3000 Series STT170 SMART TEMPERATURE TRANSMITTER Models STT171, STT173, STT17H, STT17F, STT17C 6/07 PRODUCT SPECIFICATION SHEET OVERVIEW The Honeywell STT170 series of programmable temperature transmitters

More information

Model FLSC-C1-LIQ. Microprocessor Based Loop Powered Transmitter

Model FLSC-C1-LIQ. Microprocessor Based Loop Powered Transmitter Model FLSC-C1-LIQ Microprocessor Based Loop Powered Transmitter CONTENTS 1. Introduction ------------------------------------------------------------ 2 2. Specifications-----------------------------------------------------------

More information

3DLevelScanner. Technical Data Sheet. Level Sensor. Non-Contact, Multiple-Point Measurement

3DLevelScanner. Technical Data Sheet. Level Sensor. Non-Contact, Multiple-Point Measurement Technical Data Sheet Non-Contact, Multiple-Point Measurement The 3DLevelScanner is a noncontact, dust-penetrating bin measurement device that detects irregular surfaces in powder or solid materials and

More information

Certified according to DIN EN ISO Technical Datasheet EWS. Intrinsically Safe Supply and Separation Amplifier

Certified according to DIN EN ISO Technical Datasheet EWS. Intrinsically Safe Supply and Separation Amplifier Certified according to DIN EN ISO 9001 Technical Datasheet EWS Intrinsically Safe Supply and Separation Amplifier Description... 3 Technical Data... 3 Options... 7 Notes... 7 Connections... 8 Ordering

More information

control & display PROGRAMMABLE SENSOR CONTROLLER COMPLETE VERSATILITY OF SENSOR MANAGEMENT & DATA COMMUNICATIONS

control & display PROGRAMMABLE SENSOR CONTROLLER COMPLETE VERSATILITY OF SENSOR MANAGEMENT & DATA COMMUNICATIONS S E N S O R S PROGRAMMABLE SENSOR CONTROLLER TX9044 COMPLETE VERSATILITY OF SENSOR MANAGEMENT & DATA COMMUNICATIONS Analogue sensors, temperature devices, frequency inputs and digital sensors direct fingertip

More information

Measurement. SITRANS F US Inline. 3/262 Siemens FI Transmitter SITRANS FUS080/FUE080

Measurement. SITRANS F US Inline. 3/262 Siemens FI Transmitter SITRANS FUS080/FUE080 Overview The transmitter is available in an IP67/NEMA 4X/6 enclosure and is designed for use in the flowmeters series: SONOKIT (1-path or -path) FUS80 (-path) FUE80 (-path) The transmitter FUS080 is always

More information

FDY PC-Programmable Frequency-to-DC Transmitter with Display

FDY PC-Programmable Frequency-to-DC Transmitter with Display PC-Programmable -to-dc March 2017 Description The PC-Programmable -to-dc monitors frequency, period, high or low pulse width, and contact closure signals. It converts the input signal to a proportional,

More information

Monocrystalline silicon smart differential pressure transmitter. High stability. Benefits. application DRS

Monocrystalline silicon smart differential pressure transmitter. High stability. Benefits. application DRS DRS 300 1 Monocrystalline silicon smart differential pressure transmitter DRS300 High stability Detailed Information application the flow of gas, vapor and liquid measurement with device (volume or mass

More information

KFS. Flap-type flow meter. Design and range of application

KFS. Flap-type flow meter. Design and range of application Design and range of application The measuring device operates largely independent of viscosity and is suitable for indicating the flow rate of water, acids, alkaline solutions and gases. Every device is

More information

2-WiRE LEvEL TRansmiTTER PRELEvEL 5343 ConTEnTs

2-WiRE LEvEL TRansmiTTER PRELEvEL 5343 ConTEnTs 2-wire level transmitter PRelevel 5343 Contents EC declaration of conformity... 14 Application... 15 Technical characteristics... 15 Mounting / installation... 15 Applications... 16 Electrical specifications...

More information

S T T U S I N S T R U M E N T S

S T T U S I N S T R U M E N T S S T T U S I N S T R U M E N T S Welcome to the latest Status Instruments Product Guide Here at Status Instruments, we re very proud to say that we ve been making top-quality instrumentation for 30 years.

More information

Electro-Magnetic Flowmeters COPA-XE

Electro-Magnetic Flowmeters COPA-XE Data Sheet Electro-Magnetic Flowmeters COPA-XE 10DX4311 Flowmeter system utilizes a smart microprocessor converter System accuracy of ± 0.5% of rate Field configurable via integral pushbuttons, eliminates

More information

B850 Boiler House Energy Monitor

B850 Boiler House Energy Monitor Local regulations may restrict the use of this product to below the conditions quoted. In the interests of development and improvement of the product, we reserve the right to change the specification without

More information

Coriolis Massflowmeter

Coriolis Massflowmeter Coriolis Massflowmeter for liquids and gas measuring monitoring analysing Measuring range: 0-60 kg/h 0-60 000 kg/h water Accuracy: ±0,15 of reading ±zero-point stability pmax: PN40 tmax: -40 +180 C Connection:

More information

Wireless Base Radio. Wireless Transmitters

Wireless Base Radio. Wireless Transmitters XYR 5000 Wireless Base Radio 34-XY-03-55 9/2006 WBR/WBH Europe PRODUCT SPECIFICATION AND MODEL SELECTION GUIDE Function The Wireless Base Radio (WBR) is part of the XYR 5000 family of wireless products.

More information

Rev ECN Description Approval Date AA Release to Approvals RCS 10/9/12

Rev ECN Description Approval Date AA Release to Approvals RCS 10/9/12 EB-20023137 Revision: AA Number of Pages: 13 Comments: Originator: RCS 10/05/12 Approved: RCS 10/05/12 Rev ECN Description Approval Date AA 1049085 Release to Approvals RCS 10/9/12 Micro Motion, Inc. Page

More information

Level instruments. Continuous level measurement - Radar transmitters SITRANS LR300. 5/180 Siemens FI Overview

Level instruments. Continuous level measurement - Radar transmitters SITRANS LR300. 5/180 Siemens FI Overview Overview is a 4-wire, 6 GHz pulse radar level transmitter for continuous and process vessels including high temperature and pressure, to a range of 20 m (66 ft). Benefits Auto False-Echo Suppression Infrared

More information

Certified according to DIN EN ISO Technical Datasheet. FOP 60 and OPTV. Fibre-Optic Amplifier and Receiver

Certified according to DIN EN ISO Technical Datasheet. FOP 60 and OPTV. Fibre-Optic Amplifier and Receiver Certified according to DIN EN ISO 9001 Technical Datasheet FOP 0 and OPTV Fibre-Optic Amplifier and Receiver Description... 3 Technical Data... 3 Electrical Connections... 7 Ordering Information... 8 Marking...

More information

PRODIS. PD-INC Digital Process Meter for sensors with incremental output. Digital Process Meters. Datasheet

PRODIS. PD-INC Digital Process Meter for sensors with incremental output. Digital Process Meters. Datasheet Digital Process Meters Digital Process Meter for sensors with incremental output Datasheet Copyright ASM GmbH Am Bleichbach 18-24 85452 Moosinning Germany The information presented in this data sheet does

More information

Rosemount 848L Logic Transmitter with FOUNDATION Fieldbus

Rosemount 848L Logic Transmitter with FOUNDATION Fieldbus Logic Transmitter with FOUNDATION Fieldbus Integrates Discrete I/O on a FOUNDATION Fieldbus H1 Segment Reduces Installation and Maintenance Costs with a Single Network for Analog and Discrete devices Easily

More information

Coriolis Massflowmeter

Coriolis Massflowmeter Coriolis Massflowmeter for liquids and gas measuring monitoring analysing Measuring range: 0-0.8 kg / h 0-65 000 kg / h water Accuracy: ± 0.1 of reading ±zero-point stability (liquids) pmax: PN40 tmax:

More information

Remote I/O. 74 Remote I/O. Remote I/O System

Remote I/O. 74 Remote I/O. Remote I/O System System Overview of the System Components IS1+ 76 General Information IS1+ 77 CPU & Power Modules CPU & Power Modules for Zone 1 / Div. 1 IS1+ 9440/22 78 Sockets for CPU & Power Module IS1+ 9490 78 CPU

More information

VersaFlow Ultrasonic clamp-on Flowmeter Technical Datasheet. Specification. Applications. Highlights. Industries. 34-VF September 2009

VersaFlow Ultrasonic clamp-on Flowmeter Technical Datasheet. Specification. Applications. Highlights. Industries. 34-VF September 2009 VersaFlow Ultrasonic clamp-on Flowmeter Technical Datasheet 34-VF-03-14 September 2009 Specification Clamp-on technology HONEYWELL S VERSAFLOW stands for continuity and long term reliability. Flow measurement

More information

Coriolis Mass Flow Meter Model TM

Coriolis Mass Flow Meter Model TM Coriolis Mass Flow Meter for liquids and gas measuring monitoring analysing TM S5 Measuring range: 0-0.8 kg / h 0-65000 kg / h water Accuracy: ± 0.1 of reading ± zero-point stability (liquids) p max :

More information

SITRANS F flowmeters SITRANS F US. Transmitter FUS080. 4/194 Siemens FI

SITRANS F flowmeters SITRANS F US. Transmitter FUS080. 4/194 Siemens FI Overview The transmitter is available in an IP67/NEMA X/6 enclosure and is designed for use in the flowmeters series: SONOKIT (1- or 2-track) FUS380 (2-track) FUE380 (2-track) The transmitter FUS080 is

More information

905U Wireless. New Products... New Solutions. The wireless alternative to expensive cabling... Simple but Reliable. Easy to Use

905U Wireless. New Products... New Solutions. The wireless alternative to expensive cabling... Simple but Reliable. Easy to Use Wireless New Products... New Solutions The range of telemetry modules provide remote monitoring and control by radio or twisted-pair wire, over short or long distances. Transducer signals connected at

More information

B850 Boiler House Energy Monitor

B850 Boiler House Energy Monitor Local regulations may restrict the use of this product to below the conditions quoted. In the interests of development and improvement of the product, we reserve the right to change the specification without

More information

Assembly. Front view. Switch Power Rail

Assembly. Front view. Switch Power Rail Switch Amplifier Features Assembly 1-channel isolated barrier 24 V DC supply (Power Rail) Dry contact or NAMUR input 2 passive transistor outputs (resistive acc. to EN 60947-5-6) Line fault transparency

More information

Assembly. Front view. LED yellow: Relay output I. LED red: LB/SC channel I. LED yellow: Relay output II. LED red: LB/SC channel II

Assembly. Front view. LED yellow: Relay output I. LED red: LB/SC channel I. LED yellow: Relay output II. LED red: LB/SC channel II Switch Amplifier Features Assembly -channel isolated barrier 5 V AC supply Dry contact or NAMUR inputs Relay contact output Line fault detection (LFD) Reversible mode of operation Up to SL acc. to EC 6508/EC

More information

Analog Universal Module HART for Zone 2 Series 9468/33

Analog Universal Module HART for Zone 2 Series 9468/33 > 8 channels can be adjusted individually as analog inputs or outputs > Intrinsically safe inputs/outputs Ex ia > For 0/4 20 ma + HART signals > Line fault monitoring per channel > Diagnostics based on

More information

Specification DataFile

Specification DataFile DATUM U & U Ultrasonic Level System Specification DataFile 6-digit backlit l.c.d. and bargraph clear display of measured level Echo Processing using 'DATEM' software true level measurement, overcoming

More information

Level Measurement Continuous level measurement Radar transmitters

Level Measurement Continuous level measurement Radar transmitters Overview Benefits Process Intelligence for advanced signal processing and quick and easy adjustment Self-guided quick start wizard for plug and play startup 2 GHz provides superior reflective properties

More information

Installation guide 873 SmartRadar Control Unit & Antenna Unit

Installation guide 873 SmartRadar Control Unit & Antenna Unit Installation guide 873 SmartRadar Control Unit & Antenna Unit Rev. 7 January 2006 Part no. 4416.569 Enraf BV PO Box 812 2600 AV Delft Netherlands Tel. : +31 15 2701 100 Fax : +31 15 2701 111 E-mail : info@enraf.nl

More information

SonoMeter 31 Energy Meters

SonoMeter 31 Energy Meters SonoMeter 31 Energy Meters Description MID examination certificate no.: LT-1621-MI004-023 The Danfoss SonoMeter 31 is a range of ultrasonic, compact energy meters intended for measuring energy consumption

More information

KSR-Level sensor KSR-Schwimmer-Magnetschalter KSR Contact Protection Relays

KSR-Level sensor KSR-Schwimmer-Magnetschalter KSR Contact Protection Relays KSR-Level sensor KSR-Schwimmer-Magnetschalter 1001-5 KSR Contact Protection s 1 KSR Contact Protection Type KR230-Ex and KR24-Ex General Description The contact protection relays KR230-Ex and KR24-Ex transmit

More information

General Specifications

General Specifications General Specifications YTA70 Temperature Transmitter The YTA70 is the highly accurate temperature transmitter that accepts Thermocouple, RTD, ohms or DC millivolts inputs and converts it to a to 0 ma DC

More information

All TXI7850 products are ROHS compliant.

All TXI7850 products are ROHS compliant. Features Explosion-proof NEMA 4X, IP65, Type 4 enclosure for outdoor and indoor installations. Optional tapped exhaust port vents exhaust gas. Canadian Registration Numbers (CRN) certification for all

More information

VTM Local Display Unit with Frequency and Analogue Output

VTM Local Display Unit with Frequency and Analogue Output Küppers Elektromechanik GmbH Flow Meters Liebigstr. 2 D-85757 Karlsfeld Phone +49 81 31/59 39 10 Fax + 49 81 31/9 26 04 VTM Local Display Unit with Frequency and Analogue Output The VTM is a programmable

More information

Level Measurement. Continuous level measurement Radar transmitters SITRANS LR460. 4/258 Siemens FI

Level Measurement. Continuous level measurement Radar transmitters SITRANS LR460. 4/258 Siemens FI Overview The is a -wire, 2 GHz FMCW radar level transmitter with extremely high signal-to-noise ratio and advanced signal processing for continuous monitoring of solids up to 100 m (328 ft). It is ideal

More information

Target disk flowmeters Series DP Metallic flowmeter for liquids and gases

Target disk flowmeters Series DP Metallic flowmeter for liquids and gases Target disk flowmeters Series DP Metallic flowmeter for liquids and gases Metallic, simple and robust construction Available for all flow directions Suitable for extreme pressure and temperature conditions

More information

SITRANS F flowmeters. SITRANS F R Rotary-piston meters Accessory modules 4/431. Overview. Siemens AG 2009

SITRANS F flowmeters. SITRANS F R Rotary-piston meters Accessory modules 4/431. Overview. Siemens AG 2009 Siemens AG 2009 SITRANS F flowmeters Rotary-piston meters Accessory modules Accessory modules For quantity measurements in conjunction with electromechanical and electronic pulse counters As transmitter

More information

Digital flowmeter for continuous flow measurement

Digital flowmeter for continuous flow measurement 8025 Flowmeter INSERTION Digital flowmeter for continuous flow measurement Compact or remote version for DN06 to DN400, PN10 Displays both flow rate and volume (with two totalizers) On site calibration

More information

Digital flowmeter for continuous flow measurement

Digital flowmeter for continuous flow measurement 8025 Flowmeter INSERTION Digital flowmeter for continuous flow measurement Compact or remote version for DN06 to DN400, PN10 Displays both flow rate and volume (with two totalizers) On site calibration

More information

3DLevelScanner. Technical Data Sheet. Level Sensor. Non-Contact, Multiple-Point Measurement

3DLevelScanner. Technical Data Sheet. Level Sensor. Non-Contact, Multiple-Point Measurement Technical Data Sheet Distribué par : Contact : hvssystem@hvssystem.com Tél : 0326824929 Fax : 0326851908 Non-Contact, Multiple-Point Measurement The 3DLevelScanner is a noncontact, dust-penetrating bin

More information

Digital Input Output Module for Zone 2 Series 9470/33

Digital Input Output Module for Zone 2 Series 9470/33 www.stahl.de > 16 channels can be adjusted in pairs as digital input or output > Intrinsically safe inputs/outputs Ex ia > For contacts, NAMUR proximity switches and low-power solenoid valves > Up to 8

More information

The wireless alternative to expensive cabling...

The wireless alternative to expensive cabling... The wireless alternative to expensive cabling... ELPRO 905U Wireless Solutions for Process Applications New Products... New Solutions The ELPRO 905U range of telemetry modules provide remote monitoring

More information

The wireless alternative to expensive cabling...

The wireless alternative to expensive cabling... The wireless alternative to expensive cabling... ELPRO 105U Wireless Solutions for Process Applications New Products... New Solutions The ELPRO 105U range of wireless I/O provides a low cost alternative

More information

Brunata Optuna H Ultrasonic energy meter Type 775 Installation Guide Edition 1.2

Brunata Optuna H Ultrasonic energy meter Type 775 Installation Guide Edition 1.2 Ultrasonic energy meter Type 775 Installation Guide Edition 1.2 UK-QB101575 / 29.05.2012 Brunata a/s is a Danish owned company. We have more than 90 years of experience within developing and producing

More information

TEK-TEMP 2100A. Explosion-Proof Temperature Transmitter. TEMPERATURE. Technology Solutions

TEK-TEMP 2100A. Explosion-Proof Temperature Transmitter.   TEMPERATURE. Technology Solutions Technology Solutions TEK-TEMP 2100A Explosion-Proof Temperature Transmitter TEMPERATURE www.tek-trol.com Flow Level Temperature Pressure Valves Analyzers Accessories TekValSys Introduction Tek-Trol s Explosion-Proof

More information

Assembly. Front view. LED yellow: Relay output I. LED red: LB/SC channel I. LED yellow: Relay output II. LED red: LB/SC channel II

Assembly. Front view. LED yellow: Relay output I. LED red: LB/SC channel I. LED yellow: Relay output II. LED red: LB/SC channel II Switch Amplifier Features Assembly -channel isolated barrier 30 V AC supply Dry contact or NAMUR inputs Relay contact output Line fault detection (LFD) Reversible mode of operation Up to SL acc. to EC

More information

Dial-type digital bar graph. LEDs for Open Collector, Relays and Warning Indicator

Dial-type digital bar graph. LEDs for Open Collector, Relays and Warning Indicator Specifications General Input Channels One Input Types Digital (S 3 L) Serial ASCII, TTL level, 9600 bps Frequency Range 0.5 to 1500 Hz Accuracy 0.5% of reading Measurement Types Flow, ph/orp, Conductivity/Resis

More information

Mobrey Ultrasonic. MSP422, MSP400RH, and MSP900GH Level Transmitters. Product Data Sheet February 2015 IP2045, Rev EA

Mobrey Ultrasonic. MSP422, MSP400RH, and MSP900GH Level Transmitters. Product Data Sheet February 2015 IP2045, Rev EA Mobrey Ultrasonic Product Data Sheet February 215 IP245, Rev EA MSP422, MSP4RH, and MSP9GH Level Transmitters Non-contacting measurement with no moving parts Integral LCD and push-buttons as standard for

More information

STT 3000 Series STT170 SMART TEMPERATURE TRANSMITTER Models STT171, STT173, STT17H, STT17F, STT17C

STT 3000 Series STT170 SMART TEMPERATURE TRANSMITTER Models STT171, STT173, STT17H, STT17F, STT17C STT 3000 Series STT170 SMART TEMPERATURE TRANSMITTER Models STT171, STT173, STT17H, STT17F, STT17C 34-TT-03-07 3/06 PRODUCT SPECIFICATION SHEET OVERVIEW The Honeywell STT170 series of programmable temperature

More information