2 Welcome to the latest Status Instruments Product Guide Here at Status Instruments, we re very proud to say that we ve been making top-quality instrumentation for 30 years. We ve had some remarkable successes in that time, and we ve acquired a following of loyal customers who return to us year after year. They have come to appreciate our ongoing promise - that what goes into our products is inspiration, dedication and application - and what comes out is performance, reliability and value. Quality counts Quality has always been a priority for us at every level, and we currently operate a quality system approved to BS EN ISO9001:2008. Our products also comply with current EC directives and other national standards and regulations. How to use this Guide This latest edition of our Product Guide has a bold new look, with some design and layout revisions which make it easier to use - plus some important revisions to the product groupings. As in the previous edition, each colour-coded section shows what the range has to offer, and the products are then listed individually with their relevant specification details beneath. Ordering Please place your order directly with the distributor or agent who sent you this Guide - their details should be on the back cover. If you acquired this Guide independently, please contact Status Instruments directly, and we will be able to help you. Sales team: 44 (0) Website: sales@status.co.uk Signal Conditioning Isolators, Converters and Splitters Panel Meters Humidity Transmitters Field Mounted Process Displays Wireless Temperature Transmitters Rail-mounted Transmitters Loop-powered In-head Transmitters Loop-powered Temperature Sensors, Thermowells, Heads, Accessories, etc Pressure Transmitters S T T U S I N S T R U M E N T S S T T U S I N S T R U M E N T S 2 3
3 Signal Conditioning RTD options Resistance Potentiometer Thermocouple oltage Frequency Pulse Counter Load Cell See Datasheet for specific output combinations Isolation Output zero/span alignment to input User offset User linearisation Remote reset Loop power supply Sensor power supply Max/min display Communications Totalise Maths functions Width 1600T RTD, Thermocouple and Potentiometer Input. Active or Passive or voltage output. m (10 to 10,500) Ω (1 to 100) kω auto sense K, J, N, E, T, R, S, L, U, B, C(W5), D(W3), G(W) (-100 to 200) m outputs: (Active or Passive) or oltage or Bi-Polar oltage - Resistance / Potentiometer / m (-20 to 70) C Universal, (10 to 48) DC and (10 to 32) AC - Output - direct USB 17.5 mm ± 1600I Process Signal Conditioner with Active or Passive or voltage input and output. (-50 to 50) DC (-50 to 50) outputs: (Active or Passive) or oltage or Bi-Polar oltage User linearisation (-20 to 70) C Universal, (10 to 48) DC and (10 to 32) AC - Input and Output - direct USB Flow Formulae 17.5 mm ± 1600B Load Cell Input Signal Conditioner with Active or Passive or voltage output. - 4-wire outputs: (Active or Passive) or oltage or Bi-Polar oltage - Tare (-20 to 70) C Universal, (10 to 48) DC and (10 to 32) AC - Output - direct USB 17.5 mm 1600F Dual input, single output, Frequency Conditioner and Pulse Counter, with Active or Passive or voltage output, plus relay Hz to 50 khz outputs: (Active or Passive) or oltage or Bi-Polar oltage plus relay (-20 to 70) C Universal, (10 to 48) DC and (10 to 32) AC - Output - direct USB 17.5 mm 1620 RTD, Thermocouple, Passive input, 3-wire voltage output. K, J, N, E, T, R, S (-40 to 75) m (-10 to 25) Passive Fixed-range programmable outputs: oltage, 3-wire (-20 to 70) C (15 to 28) DC - direct USB 17.5 mm Signal Conditioning 4 5 Tare ± Frequency / Pulse Count Excitation ± m o
4 Signal Conditioning RTD options Resistance Potentiometer Thermocouple oltage Frequency Pulse Counter Load Cell See Datasheet for specific output combinations Isolation Output zero/span alignment to input User offset User linearisation Remote reset Loop power supply Sensor power supply Max/min display Communications Totalise Maths functions Width 1630 RTD, Thermocouple, Passive input, with 2 change-over relay outputs. m K, J, N, E, T, R, S (-20 to 70) C 24 DC - direct USB 17.5 mm (-40 to 75) m (-10 to 25) Passive Fixed outputs: 2 x (250 1 A) change-over relay 1633 RTD, Potentiometer input, with 2 change-over relay outputs. (10 to 10,500) Ω (1 to 100) kω auto sense - relays Fixed outputs: 2 x (250 1 A) change-over relay - Resistance / Potentiometer (-20 to 70) C Universal, (10 to 48) DC and (10 to 32) AC - direct USB 17.5 mm 1636 Loop-powered Alarm Unit, with 2 change-over relay outputs. (4 to 20) Passive Fixed outputs: 2 x (250 1 A) change-over relay - relays (-20 to 70) C (4 to 20) Loop - direct USB 17.5 mm 1700 Universal Signal Conditioner with current or voltage, and 2 change-over relay outputs. (20 to 400) Ω > 1 kω K, J, N, E, T, R, S, L, U, B, C(W5), D(W3), G(W) ±200 m, ±1, ±10 ±25 (Active or Passive) outputs: (Active or Passive) or oltage plus 2 x (250 1 A) change-over relays - push-button (-20 to 70) C Universal, (20 to 250) DC and (22 to 240) AC Input and output - direct USB 22 mm 1720 Dual channel Signal Conditioner/ Splitter with temperature inputs and Active or Passive or voltage outputs. K, J, N, E, T, R, S, L, U, B, C(W5), D(W3), G(W) outputs: (Active or Passive) oltage (-20 to 70) C Universal, (20 to 250) DC and (22 to 240) AC Output, both channels - direct USB 22 mm Signal Conditioning 6 7 m 1 2
5 Signal Conditioning RTD options Resistance Potentiometer Thermocouple oltage Frequency Pulse Counter Load Cell See Datasheet for specific output combinations Isolation Output zero/span alignment to input User offset User linearisation Remote reset Loop power supply Sensor power supply Max/min display Communications Totalise Maths functions Width 1750 DUAL CHANNEL Signal Conditioner/ Splitter with Active or Passive or voltage inputs and outputs. (-50 to 50) DC (-50 to 50) (Active or Passive) outputs: (Active or Passive) oltage (-20 to 70) C Universal, (20 to 250) DC and (22 to 240) AC Input & output, both channels - direct USB 22 mm 1 2 MED 2100 series SINGLE CHANNEL Universal Input Intelligent Signal Conditioner 50 Ω to 10 kω K, J, T, R, S, E, L, N, B ±100 m, ±1, ±10 (Active or Passive) Output options: (Active or Passive) plus: 2 x (48 1 A) N/C relays or 2 x (48 1 A) C/O relays or 4 x (48 1 A) N/C relays or 2 Channel - Passive (-30 to 60) C 24 DC or or or (See output options, above) / push-button RS485 Modbus - optional custom download 35 mm MED 2200 series DUAL CHANNEL Universal Input Intelligent Signal Conditioner 50 Ω to 10 kω K, J, T, R, S, E, L, N, B ±100 m, ±1, ±10 (Active or Passive) Output options: (Active or Passive) plus: 2 x (48 1 A) N/C relays or 2 x (48 1 A) C/O relays or 4 x (48 1 A) N/C relays or 2 Channel - Passive (-30 to 60) C 24 DC (See output options, above) RS485 Modbus - optional custom download 35 mm MED 2300 series SINGLE CHANNEL Frequency Input Intelligent Signal Conditioner 0.1 Hz to 20 khz Output options: (Active or Passive) plus: 2 x (48 1 A) N/C relays or 2 x (48 1 A) C/O relays or 4 x (48 1 A) N/C relays or 2 Channel - Passive (-30 to 60) C 24 DC (See output options, above) / push-button RS485 Modbus - optional custom download 35 mm MED 2400 series DUAL CHANNEL Frequency Input Intelligent Signal Conditioner 0.1 Hz to 20 khz Output options: (Active or Passive) plus: 2 x (48 1 A) N/C relays or 2 x (48 1 A) C/O relays or 4 x (48 1 A) N/C relays or 2 Channel - Passive (-30 to 60) C 24 DC (See output options, above) RS485 Modbus - optional custom download 35 mm Signal Conditioning or or or m NAMUR TTL NPN PNP or or or m NAMUR TTL NPN PNP 1 2 or or or
6 Isolators, Converters & Splitters Type Range olt drop Maximum loop supply Isolation Maximum load Loop power supply temperature Width 1000 (4 to 20) Loop Isolator Input 5.0 DC typical load Input 35 DC (4 to 20) Passive (4 to 20) Output 500 Ω Input loop - passive (0 to 70) C 12.5 mm 1010 Provides isolated power for a transmitter, derived from a powered loop 2-wire (4 to 20) transmitter (4 to 20) Output 5.0 DC plus load Output 35 DC Output loop - passive (0 to 70) C 21 mm 1015 Converts DC voltage to an isolated (4 to 20) signal DC voltage Any between (-10 to 100) DC Output 30 DC Output loop - passive (0 to 70) C 12.5 mm Isolating current loop booster (4 to 20) Passive (4 to 20) Input and output 2.7 DC Input and output 35 DC Output 1200 Ω Both loops - passive (0 to 70) C 12.5 mm Isolating current loop splitter (4 to 20) Passive (4 to 20) (4 to 20) Active (4 to 20) Passive (4 to 20) Passive (4 to 20) Passive 2 x 2-wire (4 to 20) Passive Input and outputs 5.0 DC Input and output 32 DC Outputs 1200 Ω All loops - passive (0 to 70) C 12.5 mm 1300 Cool operating 24 DC power supply AC (90 to 253) AC (0 to 50) C 21 mm 24DC Isolators, Converters & Splitters 10 11
7 Panel Meters S Thermocouple oltage Potentiometer Load Cell Frequency / Pulse Remote Digital Inputs See Datasheet for specific output combinations Isolation Display User Linearisation Loop Power Supply Sensor Excitation Max / Min Display Comms - RS485 Modbus Maths Functions 720 Loop-powered panel meter (48 x 24) mm panel mount (Passive) 4-digit LED process display 4-digit LED 10 mm (-10 to 60) C (4 to 20) loop 3410 / Thermocouple panel meter with output options (96 x 48) mm panel mount K, J, T, R, S, E, L, N. B 2 x relay (250 5 A) POD (Active or Passive) POD RS485 Modbus option POD 4-digit LED 14.2 mm (-30 to 60) C (20 to 35) DC or (90 to 253) AC Output (option) Output (option) 3420 / voltage panel meter with output options (96 x 48) mm panel mount (Active or Passive) (0 to 1) (1 to 5) (0 to 10) DC 2 x relay (250 5 A) POD (Active or Passive) POD RS485 Modbus option POD 4-digit LED 14.2 mm (-30 to 60) C (20 to 35) DC or (90 to 253) AC Input, output (option) Output (option) 3430 High-voltage / current true RMS panel meter with output options (96 x 48) mm panel mount or or or or or or or or or 550 6A ±6A AC / DC ±550 AC / DC 2 x relay (250 5 A) POD (Active or Passive) POD RS485 Modbus option POD 4-digit LED 14.2 mm (-30 to 60) C (20 to 35) DC or (90 to 253) AC Output (option) Output (option) Panel Meters 12 13
8 Panel Meters S Thermocouple oltage Potentiometer Load Cell Frequency / Pulse Remote Digital Inputs See Datasheet for specific output combinations Isolation Display User Linearisation Loop Power Supply Sensor Excitation Max / Min Display Comms - RS485 Modbus Maths Functions 6-digit universal panel meter with output options (96 x 48) mm panel mount 3600U K, J, T, R, S, E, L, N. B (Active or Passive) ±100 m, ±1 DC, ±10 DC - with comms 2 x relay (250 5 A) POD (Active or Passive) POD RS485 Modbus option (RJ45) 6-digit LED 14.2 mm (-30 to 60) C (20 to 35) DC or (90 to 253) AC Input, output (option) / Comms option Option - with comms 3600A 6-digit universal panel meter with rate / totaliser with output options (96 x 48) mm panel mount or or or or or or K, J, T, R, S, E, L, N. B (Active or Passive) ±100 m, ±1 DC, ±10 DC - with comms 2 x relay (250 5 A) POD (Active or Passive) POD RS485 Modbus option (RJ45) 6-digit LED 14.2 mm (-30 to 60) C (20 to 35) DC or (90 to 253) AC Input, output (option) / Comms option Rate / Total Option - with comms 4500U Multi-colour 5-digit universal panel meter with load cell input with output options (96 x 48) mm panel mount K, J, T (Active or Passive) ±10 DC 2 x relay (250 8 A) option 4 x relay (250 5 A) option (Active) option RS485 Modbus option NPN / PNP logic option oltage option 5-digit LED mm multi-colour (-10 to 60) C (10.5 to 70) DC and (22 to 53) AC or (85 to 265) AC and (100 to 300) DC Input, output (option) - load cell / Comms option, and tare Option 4500F Multi-colour 5-digit panel meter with frequency / pulse counter input with output options (96 x 48) mm panel mount 2 x relay (250 8 A) option 4 x relay (250 5 A) option (Active) option RS485 Modbus option NPN / PNP logic option oltage option 5-digit LED 14.2 mm multi-colour (-10 to 60) C (10.5 to 70) DC and (22 to 53) AC or (85 to 265) AC and (100 to 300) DC Scaling Output (option) / Comms option Total / Counter Option Panel Meters Tare or or and or or or Frequency / Pulse Count Excitation or or and or or or
9 Humidity transmitters BASE ACCURACY * Supply voltage (15 to 30) DC when display fitted. Please note: images are shown with optional display fitted. Temperature range Humidity (RH) Temperature Humidity (RH) Output channels Output choices: Temperature Plug-in sensor Cable length Display option Humidity Dewpoint ΔTd - difference between dewpoint temperature and temperature 161W/H SINGLE CHANNEL wall mount humidity transmitter (-30 to 100) C (10 to 90) % ±0.5 C ± 2% RH 1 x (4 to 20) Default (10 to 30) DC * (-30 to 85) C 161D/H SINGLE CHANNEL duct mount humidity transmitter % % % (-30 to 100) C (10 to 90) % ±0.5 C ± 2% RH 1 x (4 to 20) Default (10 to 30) DC * (-30 to 85) C 161R/H SINGLE CHANNEL remote mount humidity transmitter (-30 to 100) C (10 to 90) % ±0.5 C ± 2% RH 1 x (4 to 20) Default 2 m or 5 m (10 to 30) DC * (-30 to 85) C 162W/HP DUAL CHANNEL wall mount temperature / humidity transmitter (-30 to 100) C (10 to 90) % ±0.5 C ± 2% RH 2 x (4 to 20) Default Default (10 to 30) DC * (-30 to 85) C 162D/HP DUAL CHANNEL duct mount temperature / humidity transmitter % C % C % C (-30 to 100) C (10 to 90) % ±0.5 C ± 2% RH 2 x (4 to 20) Default Default (10 to 30) DC * (-30 to 85) C 162R/HP DUAL CHANNEL remote mount temperature / humidity transmitter (-30 to 100) C (10 to 90) % ±0.5 C ± 2% RH 2 x (4 to 20) Default Default 2 m or 5 m (10 to 30) DC * (-30 to 85) C Humidity transmitters 16 17
10 Field Mounted Process Displays APPROALS Thermocouple oltage Linearisation/offset Display Max / min Battery life Enclosure Environmental rating EX ia 640P LCD battery-powered thermometer Sensor / surface mount Offset 4-digit LCD 8.5 mm (-10 to 70) C Battery 3.6 lithium 2 years typical ABS or Stainless Steel IP67 640XP ATEX-approved LCD battery-powered thermometer Sensor / surface mount Offset 4-digit LCD 8.5 mm (-10 to 50) C Battery 3.6 lithium 2 years typical ABS only IP67 LCD battery-powered thermocouple thermometer Sensor / surface mount K, J, T, R, S, E, L, N Offset 4-digit LCD 8.5 mm (-10 to 70) C Battery 3.6 lithium 2 years typical ABS or Stainless Steel 640XTC ATEX-approved LCD battery-powered thermocouple thermometer Sensor / surface mount K, J, T, R, S, E, L, N Offset 4-digit LCD 8.5 mm (-10 to 50) C Battery 3.6 lithium TC IP67 2 years typical ABS only IP67 Field Mounted Process Displays
11 Field Mounted Process Displays APPROALS Thermocouple oltage Linearisation/offset Display Max / min Battery life Enclosure Environmental rating EX ia 660 Large-digit LCD battery-powered thermometer Sensor / surface mount 4-digit LCD 20 mm (-10 to 50) C Battery 3.6 lithium 2 years typical Stainless steel 100 mm dia. IP65 Switch / links 700 (4 to 20) loop-powered LED process indicator Sensor / surface mount (4 to 20) loop (Passive) Both 4-digit LED 7 mm (-20 to 75) C (4 to 20) loop ABS or Stainless Steel IP67 ATEX-approved (4 to 20) looppowered LED process indicator Sensor / surface mount (4 to 20) loop (Passive) Both 4-digit LED 7 mm (-20 to 75) C (4 to 20) loop ABS only IP67 Head-mounted RTD, Thermocouple Transmitter with integrated display, configuration. Sensor / surface mount K, J, N, E, T, R, S 4-digit LED 7 mm (-40 to 85) C (15 to 30) DC ABS or Stainless Steel X 710 IP67 direct USB Field Mounted Process Displays
12 Wireless Temperature Transmitters RTD options Potentiometer Thermocouple oltage Custom linearisation User offset Communication Transmit / receive range Transmitter / receiver links Width WTX 700 Universal head-mounted wireless transmitter Sensor or surface-mount in SCH4, or sensor mount in SCH11 (shown). Up to 10 kω autosense J, K, T, L, U, E, N, S, R, B, C, D (0 to 50) m - set on receiver - set on receiver Measurement data on ISM band MHz m 300 m line of sight Links to any number of receivers (-30 to 70) C Battery 3.6 lithium kit (see data sheet) WTR 900 / 04 Wireless receiver for up to 16 x WTX700 DIN rail mount From radio signal From radio signal From radio signal From radio signal From radio signal - potentiometer / m range 4 x current - Active / Passive or 4 voltage RS485 Modbus for up to 16 x WTX700 plus display 300 m line of sight Links up to 16 x WTX700 (-20 to 50) C (110 to 240) AC or (20 to 30) DC kit / push-button 22.5 mm WTR 900 / 22 Wireless receiver for up to 16 x WTX700 DIN rail mount From radio signal From radio signal From radio signal From radio signal From radio signal - potentiometer / m range 2 x current - Active / Passive or 2 voltage 2 off (250 3A) C/O relay RS485 Modbus for up to 16 x WTX700 plus display 300 m line of sight Links up to 16 x WTX700 (-20 to 50) C (110 to 240) AC or (20 to 30) DC kit / push-button or 22.5 mm or Wireless Temperature Transmitters
13 Rail-mounted, loop-powered APPROALS RTD options Potentiometer Thermocouple type oltage Isolation Custom linearisation Output zero / span alignment to input Width EX ia IEC Ex 213P SINGLE CHANNEL Transmitter - push-button configuration - 2, 3-wire - 2, 3-wire - to order - push-button (-40 to 85) C (10 to 30) DC 12.5 mm 213TC SINGLE CHANNEL Thermocouple Transmitter - push-button configuration K, J, N, E, T, R, S (-10 to 70) m - push-button (-40 to 85) C (10 to 30) DC 12.5 mm 1603P SINGLE CHANNEL Transmitter - configuration - 2, 3-wire (-20 to 70) C (11 to 30) DC 17.5 mm 1603TC SINGLE CHANNEL Thermocouple Transmitter - configuration K, J, N, E, T, R, S (-40 to 75) m (4 to 20) (4 to 20) (4 to 20) (4 to 20) m m (-20 to 70) C (11 to 30) DC 17.5 mm Rail-mounted, loop-powered
14 Rail-mounted, loop-powered APPROALS RTD options Potentiometer Thermocouple type oltage Isolation Custom linearisation Output zero / span alignment to input Width EX ia IEC Ex 1610 SINGLE CHANNEL Universal Transmitter, USB direct configuration - 2, 3-wire - push-button (-20 to 70) C (11 to 30) DC / direct USB 17.5 mm m K, J, N, E, T, R, S (-40 to 75) m (0 to 20) or (4 to 20) Passive 1801/2XR SINGLE OR DUAL CHANNEL RTD, Potentiometer, Resistance Transmitter - configuration. IS-approved. - 2, 3-wire - 2, 3-wire (1 to 100) kω auto sense - Resistance / Potentiometer (-20 to 70) C (10 to 30) DC 22 mm 1801/2XTC SINGLE OR DUAL CHANNEL Thermocouple, Transmitter - configuration. IS-approved. K, J, N, E, T, R, S, L, U, B, C(W5), D(W3) G(W) - m (-20 to 70) C (10 to 30) DC 22 mm 315 SINGLE CHANNEL Universal Transmitter with HART Protocol - 2, 3, 4-wire Up to 100 kω with external resistor K, J, T, R, S, L, E, N, Custom (-10 to 85) m (4 to 20) (4 to 20) (4 to 20) (4 to 20) HART m (-20 to 70) C (10 to 40) DC / HART configurator mm Rail-mounted, loop-powered
15 In-head, loop-powered APPROALS RTD options Resistance Potentiometer input Thermocouple type oltage Isolation Custom linearisation Output zero / span alignment to input User offset EX ia IEC Ex FM Sine ibration DN Standard Gost R 203P Transmitter - push-button configuration - 2, 3-wire, to order - to order - push-button (-40 to 85) C (10 to 30) DC 43 mm 203TC Thermocouple Transmitter, - push-button configuration m K, J, N, E, T, R, S (-10 to 70) mdc - push-button (-40 to 85) C (10 to 30) DC 43 mm 206P Transmitter - configuration - 2, 3-wire (-40 to 85) C (10 to 30) DC 43 mm 206TC Thermocouple Transmitter - configuration K, J, N, E, T, R, S (-10 to 70) mdc (-40 to 85) C (10 to 30) DC 43 mm HTR 200/1 Miniature head-mounted RTD, Potentiometer, Resistance Transmitter - configuration - 2, 3-wire - 2, 3-wire (10 to 10,500) Ω (1 to 100) kω auto sense (4 to 20) (4 to 20) (4 to 20) (4 to 20) (4 to 20) m - Resistance/Potentiometer (-40 to 85) C (10 to 30) DC 50 mm (excluding cable entry) In-head, loop-powered 28 29
16 In-head, loop-powered APPROALS RTD options Resistance Potentiometer input Thermocouple type oltage Isolation Custom linearisation Output zero / span alignment to input User offset EX ia IEC Ex FM Sine ibration DN Standard Gost R HTR 200/1 Miniature head-mounted RTD, Potentiometer, Resistance Transmitter - configuration with voltage output - 2, 3-wire - 2, 3-wire (10 to 10,500) Ω (1 to 100) kω auto sense 3-wire programmable voltage output - Resistance/Potentiometer (-40 to 85) C (10 to 30) DC 50 mm (excluding cable entry) o TTR 200 RTD, Potentiometer, Resistance Transmitter - configuration. - 2, 3-wire - 2, 3-wire (10 to 10,500) Ω (1 to 100) kω auto sense (4 to 20) - Resistance/Potentiometer (-40 to 85) C (10 to 30) DC 43 mm RTD, Potentiometer, Resistance Transmitter - configuration. IS-approved. - Resistance/Potentiometer See user manual (10 to 30) DC 43 mm TTC 200 Thermocouple, m Transmitter, configuration. TTC 200X Thermocouple, m Transmitter, configuration. IS-approved. In-head, loop-powered TTR 200X - 2, 3-wire - 2, 3-wire (10 to 10,500) Ω (1 to 100) kω auto sense K, J, N, E, T, R, S, L, U, B, C(W5), D(W3), G(W) (-100 to 200) m - m (-40 to 85) C (10 to 30) DC 43 mm m K, J, N, E, T, R, S, L, U, B, C(W5), D(W3), G(W) (-100 to 200) m (4 to 20) (4 to 20) (4 to 20) - m See user manual (10 to 30) DC 43 mm m
17 In-head, loop-powered APPROALS RTD options Resistance Potentiometer input Thermocouple type oltage Isolation Custom linearisation Output zero / span alignment to input User offset Width / diameter EX ia IEC Ex FM Sine ibration DN Standard Gost R 210 RTD, Thermocouple, Potentiometer, m Transmitter, configuration. m - 2, 3-wire (1 to 100) kω auto sense K, J, N, E, T, R, S (-10 to 75) m (-40 to 85) C (10 to 30) DC 43 mm dia. 210X RTD, Thermocouple, Potentiometer, m Transmitter, configuration. IS-approved. m - 2, 3-wire (1 to 100) kω auto sense K, J, N, E, T, R, S (-10 to 75) m (-40 to 85) C (10 to 30) DC 43 mm dia. HART Protocol RTD, Thermocouple, Slidewire, m Transmitter, configuration. HART Protocol RTD, Thermocouple, Slidewire, m Transmitter, configuration. IS-approved. In-head, loop-powered m (-40 to 85) C (10 to 40) DC / HART configurator 44 mm dia. - 2, 3 and 4-wire Up to 100 kω with external resistor K, J, T, R, S, E, L, N, Custom (-10 to 75) m 310X m (-40 to 85) C (10 to 40) DC / HART configurator 44 mm dia. - 2, 3 and 4-wire Up to 100 kω with external resistor K, J, T, R, S, E, L, N, Custom (-10 to 75) m (4 to 20) (4 to 20) (4 to 20) HART (4 to 20) HART
18 Temperature sensors (images not necessarily to scale) You tell us. An extensive range is shown here, but we can supply probes and sensors to almost any specification. Please contact our Sales Team for more details. The specification details opposite reflect popular choices, but we can supply products to suit almost any need. Please call to discuss your requirements. Sensing Process Extension Head Wire leads Temperature range Immersion lengths Style 1 Temperature sensor with fixed process connection. Immersion length (parallel ) Immersion length (tapered ) Extension length 6 mm dia. typical 1/2 BSP typical Typically 75 mm long x 12.7 mm dia. M24, 1/2 BSP or your choice PTFE 150 mm typical Head Extension Process Style 2 Temperature sensor for use with a compression gland. 6 mm dia. typical Immersion length M24, 1/2 BSP or your choice PTFE 150 mm typical Head Style 3 Temperature sensor with removable inset sensor. Immersion length (parallel ) Immersion length (tapered ) Extension length 7.9 mm dia. typical 1/2 BSP typical Typically 75 mm long x 12.7 mm dia. M24, 1/2 BSP or your choice PTFE 150 mm typical Inset Head Extension Process Style 4 Flying lead temperature sensor for use with a compression gland. 6 mm dia. typical Immersion length Cable length PTFE 1 m long typical Cable Style 5 Flying lead strap-on temperature probe for surface temperature measurement. 1/4 square typical Typically 19 mm long x 4 mm dia. length Extension Cable length length PTFE 1 m long typical Cable Extension Style 6 Temperature probe for energy management applications. Can only be used with SCH4 head. 6 mm dia. typical Immersion length PTFE 75 mm typical Temperature sensors Material Usually 316 stainless steel Usually 316 stainless steel Usually 316 stainless steel Usually 316 stainless steel Usually aluminium Usually 316 stainless steel 34 35
19 Temperature sensors (images not necessarily to scale) You tell us. An extensive range is shown here, but we can supply probes and sensors to almost any specification. Please contact our Sales Team for more details. The specification details opposite reflect popular choices, but we can supply products to suit almost any need. Please call to discuss your requirements. Sensing Process Extension Head Wire leads Temperature range Immersion lengths Style 7 Outdoor air temperature probe. Can only be used with SCH4 or SCH15 heads. length 12.7 mm dia. typical M16 only PTFE 75 mm typical Head Style 8 Flying lead temperature probe for use with Field Mounted Displays. 6 mm dia. typical length Cable length Usually M16 PTFE 1 m long typical Head Cable Style 9 Temperature probe for use with Field Mounted Displays. Allows the head display to be orientated. Extension length Immersion length (parallel ) Immersion length (tapered ) 6 mm dia. typical 1/2 BSP typical Typically 75 mm long x 12.7 mm dia. Usually M16 PTFE 150 mm typical Male running nut Extension Process Style 10 Temperature probe for screw fitting into an internal hygienic type process connection. Immersion length (parallel ) Extension length 6 mm dia. typical 3/4 BSP male, typical Typically 75 mm long x 12.7 mm dia. M24, 1/2 BSP or your choice PTFE 150 mm typical Extension Process / male running nut Style 11 Temperature probe for screw fitting into an external hygienic type process connection. Immersion length (parallel ) Extension length 6 mm dia. typical 3/4 BSP female, typical Typically 75 mm long x 12.7 mm dia. M24, 1/2 BSP or your choice PTFE 150 mm typical Head Extension Process / female running nut Style 12 Temperature probe for fitting to hygienic process connections such as IDF, RJT, or SMS. Immersion length (parallel ) Extension length 6 mm dia. typical To special order Typically 75 mm long x 12.7 mm dia. M24, 1/2 BSP or your choice PTFE 150 mm typical Head Extension Hygienic fitting Female running nut Temperature sensors Material Usually 316 stainless steel Usually 316 stainless steel Usually 316 stainless steel Usually 316 stainless steel Usually 316 stainless steel Usually 316 stainless steel 36 37
20 Thermowells & Pockets (images not necessarily to scale) You tell us. An extensive range is shown here, but we can supply thermowells and pockets to almost any specification. Please contact our Sales Team for more details. The specification details opposite reflect popular choices, but we can supply products to suit almost any need. Please call to discuss your requirements. Parallel sheath Tapered sheath Process Internal Compression fitting Immersion length Material Flange STW Style 1 Thermowell for use with temperature sensors styles 1 and mm dia. typical 3/4 BSP typical 1/2 BSP typical Usually 316 stainless steel Immersion length (parallel ) Immersion length (tapered ) Internal Process Bore diameter STW Style 2 Thermowell for use with temperature sensors styles 2, 4 and 6. Immersion length (parallel ) 7.9 mm dia. typical 1/2 BSPT typical 1/4 BSPT x 6 mm typical Usually 316 stainless steel / compression gland brass Immersion length (tapered ) Compression gland Process Bore diameter STW Style 3 Weld-in thermowell for styles 1 and 9 temperature probes, and styles 2, 4 and 6 with compression gland. 7.9 mm dia. typical 1/2 BSP typical Usually 316 stainless steel STW Style 4 Solid turned thermowell for use where higher mechanical strength is required. For use with styles 1 and 9. Head height 3/4 BSP typical 1/2 BSP typical Usually 316 stainless steel Immersion length (parallel ) Immersion length (tapered ) Internal Head Process Major dia. Minor dia. Bore diameter STW Style 5 Fabricated flanged thermowell, usually with adjustable extension and spring-loaded inset sensor. Immersion length Spigot length 7.9 mm dia. typical 1/2 BSP typical Usually 316 stainless steel Internal Flange Bore diameter STW Style 6 Solid turned (for high strength) flanged thermowell, usually with adjustable extension and spring-loaded inset sensor. Immersion length Spigot length 1/2 BSP typical Usually 316 stainless steel Internal Flange Major dia. Minor dia. Bore diameter Thermowells & Pockets Immersion length Head height Internal Bore diameter
21 Heads, Accessories, etc Heads Display window when used with - Cable entry Sensor entry Protection Mounting Body entry styles Approvals Accessories Stocked versions Your spec Material Terminals SCH4 ABS plastic connection head / terminal box. 600 / 700 / 710 and 160 M16, M20, M24, 1/2 M16, M20, M24, 1/2 IP67 Head, wall, duct, pipe Base / side Side / side Side only Compression glands For use with 2 / 4 temperature sensors. 1/4 BSP or 1/2 BSP x 6 mm To order 316 stainless steel SCH11 Aluminium alloy connection head. M20 M24 IP67 Head Base / side - - CB4 / CB6 Connection blocks, for use where high temperatures are to be measured. In stock Ceramic 4 or 6 way SCH15 Stainless steel connection head for use with 600 / / 700 / 710 M20 M16 IP67 Head - Side / side Side only Mounting kit SMK For mounting transmitters or connection blocks to heads fitted with style 3 sensors In stock SCH50 Exd ATEX explosion-proof aluminium alloy / stainless steel connection head. Loop indicator based on 700 M16, M20, M24, 1/2 M16, M20, M24, 1/2 IP67 Head, wall, duct, pipe Base / side Side / side Side only Exd flameproof head Mounting kit RMK /1G For mounting in head transmitters to DIN G rail In stock (images not necessarily to scale) Mounting kit RMK / 3T For mounting in head transmitters to DIN top hat rail In stock Sensor / transmitter Sensing element Measuring range typical Process Immersion lengths Material Accuracy Ouput STA 206 Cost-effective temperature sensor with built-in transmitter class A (-50 to 200) C 6 mm dia. 1/2 BSP to your spec 316 stainless steel 0.25% FRS (10 to 30) DC (4 to 20) Heads, Accessories, etc 40 41
22 Pressure transmitters PROCESS CONNECTION APPROALS Pressure Range 2-wire (4 to 20) loop-powered oltage output 1/4 BSP 1/4 NPT 1/2 BSP 1/2 BSP flush Other to order Open or closed ends Exia PTX 130/1/2 General purpose pressure transmitter General purpose pressure transmitter ATEX-approved general purpose pressure transmitter ATEX-approved general purpose submersible level transmitter Up to 700 Bar Below 1 Bar Up to 1000 Bar Up to 250m H 2 O (optional) PTX 130/3/4 (optional) PTX 19 PTX 20 Pressure transmitters 42 43
23 S T T U S I N S T R U M E N T S Every effort has been made to ensure the accuracy of the information contained in this Product Guide, but the company accepts no liability for any errors or omissions. Unless previously agreed in writing, all transactions are subject to our standard Terms and Conditions of sale, available on request or from our website, at
SEM210 SERIES. Programmable In-head Universal Temperature Transmitter INDEX SECTION CONTENTS PAGE NO.
INDEX SECTION CONTENTS PAGE NO. SEM210 SERIES 1.0 DESCRIPTION 1 2.0 SPECIFICATION 15 3.0 INSTALLATION 67 Programmable Inhead Universal Temperature Transmitter Status Instruments Ltd, Green Lane Business
More informationSEM1600T RTD/TC/SLIDE WIRE SIGNAL CONDITIONER
RTD, THERMOCOUPLE, THERMISTOR (BMS SENSORS), SLIDE WIRE, mv AND RESISTANCE INPUTS ma, VOLTAGE OR BIPOLAR VOLTAGE OUTPUT SENSOR OFFSET (TEMPERATURE) 22 SEGMENT USER LINEARISATION (PROCESS) CONFIGURATION
More informationDigital flow transmitter for continuous flow measurement
Digital flow transmitter for continuous flow measurement Compact or remote version for DN 06 to 400, PN10 Shows both flow rate and volume (with two totalizers) Automatic-calibration: TEACH-IN Simulation:
More informationSEM210 SEM210X UNIVERSAL TEMPERATURE TRANSMITTER
UNIVERSAL INPUT, DUAL CHANNEL ATEX & IEC Ex Version MATHS FUNCTIONS SENSOR CHARACTERISTICS DOWNLOAD VIA USB PORT ALLOWS FOR CUSTOM TYPES FLASH TESTED TO 4 KV DC INTRODUCTION The SEM210 is a universal transmitter
More informationResistance thermometer Model TR30, compact design
Electrical temperature measurement Resistance thermometer Model TR30, compact design WIKA data sheet TE 60.30 Applications Machine building, plant and vessel construction Propulsion technology, hydraulics
More informationCombiTemp TCR6 Standard RTD temperature sensor
Main features Sensor and connection in stainless steel, ISI 6 DIN form B housing Robust design pplications Industrial applications with industrial process connection Pipe systems Heating systems Water
More informationSITRANS T measuring instruments for temperature
Overview Our field devices for heavy industrial use HART, Universal 4 to 20 ma, universal Field indicator for 4 to 20 ma signals The temperature transmitter SITRANS TF works where others feel uncomfortable.
More informationDigital conductivity transmitter
Digital conductivity transmitter Compact version with integrated conductivity electrodes Remote version with seperated transmitter for short (15 ft.) or long (1500 ft.) distance Commissioning is easy due
More informationInfocal 9 Energy calculator
Infocal 9 Energy calculator Description/Application MID examination certificate no.: LT-1621-MI004-028 The INFOCAL 9 is an energy calculator, e.g. for combination with or SonoSensor 30. It is especially
More informationJUMO Wtrans E01. Measuring probe for humidity, temperature, and CO 2 with wireless data transmission. Brief description. Universal Wtrans receiver
Page 1/13 JUMO Wtrans E01 Measuring probe for humidity, temperature, and CO 2 with wireless data transmission Humidity from 0 to 100 % RH (incl. -40 to +80 C) or CO 2 from 0 to 2000/5000/10000 ppm or Temperature
More informationRHE12. Hazardous Area Coriolis Mass Flow Transmitter. Features. Applications. Benefits
RHE12 Hazardous Area Coriolis Mass Flow Transmitter Features Field mounting Compact, pressure safe housing ATEX and CSA approvals for installation in hazardous areas 24 VDC power supply Configurable analog
More informationSonoMeter 31 Energy Meters
SonoMeter 31 Energy Meters Description MID examination certificate no.: LT-1621-MI004-023 The Danfoss SonoMeter 31 is a range of ultrasonic, compact energy meters intended for measuring energy consumption
More informationHART field temperature transmitter Models TIF50, TIF52, TIF62
Electrical temperature measurement HART field temperature transmitter Models TIF50, TIF52, TIF62 WIKA data sheet TE 62.01 Applications Plant construction Process engineering General industrial applications
More informationcontrol & display PROGRAMMABLE SENSOR CONTROLLER COMPLETE VERSATILITY OF SENSOR MANAGEMENT & DATA COMMUNICATIONS
S E N S O R S PROGRAMMABLE SENSOR CONTROLLER TX9044 COMPLETE VERSATILITY OF SENSOR MANAGEMENT & DATA COMMUNICATIONS Analogue sensors, temperature devices, frequency inputs and digital sensors direct fingertip
More informationResistance thermometer Model TR30, compact design
Electrical temperature measurement Resistance thermometer Model TR30, compact design WIKA data sheet TE 60.30 Applications Machine building, plant and vessel construction Propulsion technology, hydraulics
More informationDigital flow ELEMENT transmitter for continuous flow measurement
ELEMENT Transmitter Digital flow ELEMENT transmitter for continuous flow measurement Type can be combined with... PN10, DN15 to DN400 fluidic process connection Programmable outputs : one or two transistor
More informationDatasheet Platinum Resistance Pt100 In-head (Push Button) Temperature Transmitter TX203P mA output, default range supplied C
Datasheet Platinum Resistance Pt100 In-head (Push Button) Temperature Transmitter TX203P - 4-20mA output, default range supplied 0-100 C ENGLISH The TX203P RTD in-head mounted temperature transmitter connects
More informationMiniature resistance thermometer Explosion-protected version Model TR34, thread-mounted
Electrical temperature measurement Miniature resistance thermometer Explosion-protected version Model TR34, thread-mounted WIKA data sheet TE 60.34 Applications Machine building, plant and vessel construction
More informationIsolators A3/1.
Temperature Transmitter Series 9182 > One unit for nearly all temperature sensors indivdually configurable > Signal duplication possible > Galvanic isolation between input, output, power supply and configuration
More information600T Series Transmitters Model 653L Electronic temperature transmitter (PC programmable for RTD and resistance) Specification Sheet
Specification Sheet 600T Series Transmitters Model 65L Electronic temperature transmitter (PC programmable for RTD and resistance) High flexibility and wide rangeability Primary element and calibration
More informationCONTA-ELECTRONICS. Converter Units
CONTA-ELECTRONICS Whether for manufacturing, electrical machine and plant instrumentation, control engineering, power distribution, building automation, or process engineering it is always important to
More informationResistance thermometer Model TR31, miniature design
Electrical temperature measurement Resistance thermometer Model TR31, miniature design WIKA data sheet TE 60.31 Applications Machine building, plant and vessel construction Propulsion technology, hydraulics
More informationCoriolis Massflowmeter
Coriolis Massflowmeter for liquids and gas measuring monitoring analysing Measuring range: 0-0.8 kg / h 0-65 000 kg / h water Accuracy: ± 0.1 of reading ±zero-point stability (liquids) pmax: PN40 tmax:
More informationMODEL: B6U-B B6-UNIT. [2] LCD DISPLAY 0: Without 1: With
Field-mounted Two-wire Signal Conditioners B6-UNIT 8: TIIS flameproof (CE not available) Confirm selectable combinations of approval and wiring conduit types in the table. 2-WIRE UNIVERSAL TEMPERATURE
More information600T Series Transmitters. Specification Sheet. Model 653T Electronic temperature transmitter (PC programmable)
Specification Sheet 600T Series Transmitters Model 65T Electronic temperature transmitter (PC programmable) High flexibility and wide rangeability Single transmitter accepts RTD/THC/mV/ohm Galvanically
More information09746E00. ATEX / IECEx NEC 505 NEC 506 NEC 500 Class I Class I Class II Class III Zone Zone Division Ex i
Temperature Transmitter Series 9182 www.stahl.de > One unit for nearly all temperature sensors indivdually configurable > Intrinsically safe input [Ex ia] IIC > Signal duplication possible > Galvanic isolation
More informationTMU. Coriolis Mass Flow Meter. for liquids and gas
Coriolis Mass Flow Meter for liquids and gas measuring monitoring analysing TMU S5 OO Measuring range: 0-60 kg/h 0-2200 t/h water OO Accuracy: ± 0.1% of reading ±zero point stability (from liquids up to
More informationCoriolis Massflowmeter
Coriolis Massflowmeter for liquids and gas measuring monitoring analysing Measuring range: 0-60 kg/h 0-60 000 kg/h water Accuracy: ±0,15 of reading ±zero-point stability pmax: PN40 tmax: -40 +180 C Connection:
More informationMiniature resistance thermometer Model TR33, thread-mounted
Electrical temperature measurement Miniature resistance thermometer Model TR33, thread-mounted WIKA data sheet TE 60.33 Applications Machine building, plant and vessel construction Propulsion technology,
More informationDigital flowmeter for continuous flow measurement
8025 Flowmeter INSERTION Digital flowmeter for continuous flow measurement Compact or remote version for DN06 to DN400, PN10 Displays both flow rate and volume (with two totalizers) On site calibration
More informationDigital flowmeter for continuous flow measurement
8025 Flowmeter INSERTION Digital flowmeter for continuous flow measurement Compact or remote version for DN06 to DN400, PN10 Displays both flow rate and volume (with two totalizers) On site calibration
More informationUTM10 Series Ultrasonic Transit-time Flowmeters
Ultrasonic Transit-time meters Description UTM10 ultrasonic flow and energy meters clamp onto the outside of pipes and do not make contact with the internal liquid. The technology has inherent advantages
More informationField indicator for current loops with HART communication Models DIH50, DIH52
Accessories Field indicator for current loops with HART communication Models DIH50, DIH52 WIKA data sheet AC 80.10 for further approvals see page 6 Applications Process engineering Plant construction General
More informationPAD - Heavy Duty Differential Pressure Trasmitter
Benefits and Features Span: 0.3" W.C. 6" W.C. to 60 6000 PSIG Static Pressure: Max. 4500 PSIG t max : 248 F Process Connection: ½" NPT, ¼" NPT, or Various Diaphragm Seals Available upon Request Material:
More informationRosemount 848L Logic Transmitter with FOUNDATION Fieldbus
Logic Transmitter with FOUNDATION Fieldbus Integrates Discrete I/O on a FOUNDATION Fieldbus H1 Segment Reduces Installation and Maintenance Costs with a Single Network for Analog and Discrete devices Easily
More informationFlow Measurement SITRANS F M
Overview Mode of operation The flow measuring principle is based on Faraday s law of electromagnetic induction according to which the sensor converts the flow into an electrical voltage proportional to
More informationSITRANS F flowmeters SITRANS F M. Flow sensor MAG /48 Siemens FI Overview
Siemens AG 2009 Overview Integration The complete flowmeter consists of a flow sensor and an associated transmitter MAG 5000, 6000 or 6000 I. The flexible communication concept USM II simplifies integration
More informationJUMO Wtrans probe RTD temperature probe with wireless transmission of the measured values
JUMO Wtrans probe RTD temperature probe with wireless transmission of the measured values k For measured temperatures from -30... +260 C or -200... +600 C k For mobile or stationary temperature measurement
More informationResistance Thermometers Model Series TR7X0, Sheathed Design
Electrical Temperature Measurement Resistance Thermometers Model Series TR7X0, Sheathed Design WIKA Data Sheet TE 60.40 Applications T Suitable for all industrial and laboratory applications Special Features
More informationSITRANS F flowmeters SITRANS F US. Transmitter FUS080. 4/194 Siemens FI
Overview The transmitter is available in an IP67/NEMA X/6 enclosure and is designed for use in the flowmeters series: SONOKIT (1- or 2-track) FUS380 (2-track) FUE380 (2-track) The transmitter FUS080 is
More informationFlow Measurement SITRANS F M. Flow sensor MAG /49. Overview
Siemens AG 2010 Flow Measurement Overview Mode of operation The flow measuring principle is based on Faraday s law of electromagnetic induction according to which the sensor converts the flow into an electrical
More informationRTD Temperature Sensor omnigrad T -TSM 480, TR 480. Hygienic RTD sensor with Pt 100, class A TSM 480 with electronics programmable via PC
Technical Information TI 273T/02/en 60021667 RTD Temperature Sensor omnigrad T -TSM 480, TR 480 Hygienic RTD sensor with Pt 100, class A TSM 480 with electronics programmable via PC Application The Omingrad
More informationOEM miniature resistance thermometer Models TR31-3 and TR31-K, thread-mounted
Electrical temperature measurement OEM miniature resistance thermometer Models TR31-3 and TR31-K, thread-mounted WIKA data sheet TE 60.31 further approvals see page 10 Applications Machine building, plant
More informationLevel Measurement Continuous level measurement Radar transmitters
Overview Benefits Process Intelligence for advanced signal processing and quick and easy adjustment Self-guided quick start wizard for plug and play startup 2 GHz provides superior reflective properties
More informationIsolators A3/1. Temperature Transmitter Field Circuit Non-Ex i Series
Temperature Transmitter Series 9182 > One unit for nearly all temperature sensors indivdually configurable > Signal duplication possible > Galvanic isolation between input, output, power supply and configuration
More informationTemperature Measurement
Overview Application transmitters can be used in all industrial sectors. Due to their compact size they can be installed in the connection head type B (DIN 4729) or larger. The following sensors/signal
More information4-20mA, 0-10V and general process measuring bargraph displays
Page 1 of 6 Digital panel meters Large displays Bargraphs Transmitters 4-20mA, 0-10V process input bargraph displays Display almost any physical variable... The bargraph displays on this page accept most
More information3 Ex i Isolators. Temperature Transmitter without Output 0/ ma, with Limit Value Contact (Field Circuit Ex i) Type 9182/.
Ex i Isolators Temperature Transmitter without Output 0/4... 20 ma, with Limit Value Contact Field Circuit Ex i) One unit for nearly all temperature sensors indivdually configurable Intrinsically safe
More informationomnigrad T - TSM 480, TR 480. Technical Information. RTD Temperature Sensor Hygienic design TSM 480 with electronics programmable via PC
Technical Information omnigrad T - TSM 480, TR 480 RTD Temperature Sensor Hygienic design TSM 480 with electronics programmable via PC Application areas The onmigrad T easytemp TSM 480 and TR 480 thermometers
More informationPR product range - links to order details and block diagrams
PR product range links to order details and block diagrams 2202 2204 2220 2222 2223 2224 2229 2231 2237 2238 2240 2241 2255 2261 2271 2273 2279 2281 2284 2285 2286 2288 2289 2914 3532 4114 4116 4131 5102
More informationValve Island with Electronic I/O
Screw in Temperature /Switch with display for ON/OFF Control Indication, monitoring, transmission and ON/OFF control in one device Extra large display Menu guided parametrisation Complete communication
More informationSEM104 SERIES. SEM104P Pt100 Temperature Transmitter. SEM104TC Thermocouple Temperature Transmitter INDEX SECTION CONTENTS PAGE NO.
INDEX SECTION CONTENTS PAGE NO. SEM104 SERIES SEM104P Pt100 Temperature Transmitter SEM104TC Thermocouple Temperature Transmitter SEM104P 1 1.0 DESCRIPTION 2 2.0 SPECIFICATION 2 3.0 INSTALLATION 24 4.0
More informationAccuracy: ± 0.1 % of reading ±zero point stability (from liquids up to TMU-x040) Material: (316 L) / (316 Ti)/ Hastelloy C-22
Coriolis Massflowmeter for liquids and gas measuring monitoring analysing TMU S5 Measuring range: 0-60 kg/h 0-2200 t/h water Accuracy: ± 0.1 % of reading ±zero point stability (from liquids up to TMU-x040)
More informationFlow Switch - 2 programmable thresholds. Stand Alone (Battery) - Battery powered, - 2 totalizers display, - Local flow display,
DN 15 - DN 50; PN Advantages / Benefits Easy System integration by Easy LINK provides low cost of ownership Easy commissioning due to multi-language, menu-guided operation TEACH-IN: automatic calibration
More information3 Ex i Isolators. Temperature Transmitter with Output 0/ ma, without Limit Value Contact (Field Circuit Ex i) Type 9182/.0-5.
Ex i Isolators Temperature Transmitter with Output 0/4... 20 ma, without Limit Value Contact Field Circuit Ex i) One unit for nearly all temperature sensors indivdually configurable Intrinsically safe
More informationTF 02 / TF 02-Ex. Head mounted temperature transmitters, FOUNDATION Fieldbus (H1), Pt 100 (RTD), thermocouples, 1 or 2 independent channels
TF 0 / TF 0-Ex Head mounted temperature transmitters, FOUNDATION Fieldbus (H), Pt 00 (RTD), thermocouples, or independent channels 0/-8.5 EN Input Resistance thermometer (,, wire circuit) Thermocouples
More informationProcess transmitter Model UPT-20, with pressure port Model UPT-21, with flush diaphragm
Electronic pressure measurement Process transmitter Model UPT-20, with pressure port Model UPT-21, with flush diaphragm WIKA data sheet PE 86.05 Applications Process technology Machine building and plant
More informationMeasurement and Instrumentation
POWER QUALITY ENERGY PERFORMANCE Measurement and Instrumentation Overview of ranges Selection guide Info & advice Economical range for industrial use μdigi1 - μdigi2 ranges Programmable range for universal
More informationUltrasonic level meters ULM 70
průmyslová elektronika Ultrasonic level meters ULM 70 For continuous level measurement of liquids (even if polluted), mash and paste materials in open or closed vessels, sumps, open channels, drains, etc.
More informationPRODUCT SPECIFICATION AND MODEL SELECTION GUIDE
XYR 5000 Wireless Temperature Transmitters WT530 34-XY-03-02 09/2006 PRODUCT SPECIFICATION AND MODEL SELECTION GUIDE Function The WT530 Temperature Transmitter is part of the XYR 5000 family of wireless
More informationSITRANS F flowmeters SITRANS F M. Transmitter Transmag 2 with sensor 911/E 4/77. Overview
Overview Design The complete flowmeter consists of a flow sensor and an associated transmitter from the Transmag 2 for pulsed alternating field. These are available as remote and compact versions ( 911/E
More informationType PLC Fitting. Valve for Continuous control. Diaphragm valve. Output
Digital Inductive conductivity transmitter Optimal solution for conductivity measurements in difficult fluids (polluted, dirty,...) PEEK/PPA version for CIP applications Large range of process connections
More informationDigital inductive conductivity transmitter
Digital inductive conductivity transmitter Optimal solution for conductivity measurements in difficult fluids (polluted, dirty,...) PEEK/PPA version for CIP applications Large range of process connections
More informationMODEL: M2XU MODEL: M2XU [1][2] [3][4]
Super-mini Signal Conditioners Mini-M Series UNIVERSAL TRANSMITTER (PC programmable) Functions & Features Accepts direct inputs from various sensors and provides a standard process signal I/O types and
More informationTEK-TEMP 2100A. Explosion-Proof Temperature Transmitter. TEMPERATURE. Technology Solutions
Technology Solutions TEK-TEMP 2100A Explosion-Proof Temperature Transmitter TEMPERATURE www.tek-trol.com Flow Level Temperature Pressure Valves Analyzers Accessories TekValSys Introduction Tek-Trol s Explosion-Proof
More informationMobrey Ultrasonic. MSP422, MSP400RH, and MSP900GH Level Transmitters. Product Data Sheet February 2015 IP2045, Rev EA
Mobrey Ultrasonic Product Data Sheet February 215 IP245, Rev EA MSP422, MSP4RH, and MSP9GH Level Transmitters Non-contacting measurement with no moving parts Integral LCD and push-buttons as standard for
More informationRHE11. Hazardous Area Multifunction Coriolis Flow Transmitter. Features. Applications. Benefits
RHE11 Hazardous Area Multifunction Coriolis Flow Transmitter Features Wall or Pipe Bracket Mount Built in safety barriers allow operation with RHM sensor in hazardous area Selectable Metric and English
More informationLevel Measurement Continuous level measurement Radar transmitters
Overview Configuration Mounting on a nozzle is a 2-wire 25 GHz pulse radar level transmitter for continuous monitoring of solids and liquids in storage vessels including extreme levels of dust and high
More informationTemperature Transmitters - Head Mounted
XTH Features - Non-programmable Models Sensor Types: Models for thermocouple Types J, K, or T Models for RTD Type Pt100 3-wire Select from a variety of pre-configured measuring ranges Internal cold junction
More informationDigital Temperature Transmitters Model T12.10, Universally Programmable, Head Mounting Model T12.30, Universally Programmable, Rail Mounting
Electrical Temperature Measurement Digital Temperature Transmitters Model T12.10, Universally Programmable, Head Mounting Model T12.30, Universally Programmable, Rail Mounting WIKA Data Sheet TE 12.03
More informationDigital flow ELEMENT transmitter for continuous flow measurement
Digital flow ELEMENT transmitter for continuous flow measurement Type 8036 can be combined with... DN06 to DN65 fluidic process connection Programmable outputs : one or two transistor output(s) and single
More informationOEM miniature resistance thermometer Models TR31-3 and TR31-K, thread-mounted
Electrical temperature measurement OEM miniature resistance thermometer Models TR31-3 and TR31-K, thread-mounted WIKA data sheet TE 60.31 Applications Machine building, plant and vessel construction Propulsion
More informationINSERTION paddle wheel flowmeter for continuous flow measurement
INSERTION paddle wheel flowmeter for continuous flow measurement Economic integration in pipe systems without any additional piping 3-wire frequency pulse version to directly interface with PLC s (both
More informationTemperature transmitter itemp PCP DIN rail TMT 121
Technical information TI 087R/09/en 510 03671 Temperature transmitter itemp PCP DIN rail TMT 121 Universal temperature transmitter for resistance thermometers (RTD), thermocouples, resistance and voltage
More informationDIGITAL PANEL METERS. Overview of product range. Product selection guide. Info & advice. µdigi1 and µdigi2 ranges
ENERGY METERS 099 0 0 0 Overview of product range General overview Product selection guide by functions by applications Info & advice Keeping up with current changes µdigi and µdigi ranges x8 mm or 8x9
More informationmass flowmeter for compressed air
mass flowmeter for compressed air VARIOMASS MF High End electronic for air measurement & analyse - 1 - The VARIOMASS flow meter for compressed air is a comfortable system for air mass flow measurement,
More informationKMS305W. ManuFlo Page 1 MANU ELECTRONICS PTY LTD Flow Measurement Products. Electromagnetic Wafer Flowmeters with S300 display
Electromagnetic Wafer Flowmeters with S300 display for corrosive chemicals/acids & slurries (sizes: 2.5mm to 100mm) 0BFEATURES: For aggressive chemicals, slurries, oxides, grouts & dosing applications
More informationGS Strain gauge reader/ transmitter. GS series of wireless industrial sensors. Features: General Description: Applications:
GS series of wireless industrial sensors Strain gauge reader/ transmitter Features: Input: strain gauge Wheatstone bridge: 300ohms to 10kohms. Typical: 1000 ohms. Standard input range: up to 2mV/V full
More informationCoriolis Mass Flow Meter Model TM
Coriolis Mass Flow Meter for liquids and gas measuring monitoring analysing TM S5 Measuring range: 0-0.8 kg / h 0-65000 kg / h water Accuracy: ± 0.1 of reading ± zero-point stability (liquids) p max :
More informationData Sheet KFD2-UFC-EX1.D. Supplied by. .com. Call us on +44 (0)
Data Sheet KFD-UFC-EX1.D Supplied by.com Call us on +44 (0)118 916 940 Email info@47able.com Frequency Converter with Trip Values Features Assembly 1-channel isolated barrier 4 V DC supply (Power Rail)
More informationThe Rosemount 848T Wireless Temperature Transmitter
Rosemount 88T Family February 0 The Rosemount 88T Wireless Temperature Transmitter The Rosemount 88T is the premier choice for Wireless High Density measurements. Four independently configurable inputs
More informationFAHM Co. Temperature Transmitter
FAHM Co. Temperature Transmitter PTT74-Ex Series The PTT74-Ex is a versatile temperature transmitter that delivers field reliability and advanced accuracy and stability to meet demanding process needs.
More informationRosemount 148 Temperature Transmitter
Product Data Sheet Rosemount 148 Rosemount 148 Temperature Transmitter Provides an installation-ready solution for temperature monitoring applications using Complete Point Solutions (CPS) Increases measurement
More informationcontrol & display PROGRAMMABLE SENSOR CONTROLLER COMPLETE VERSATILITY OF UNDERGROUND SENSOR MANAGEMENT & DATA COMMUNICATIONS
PROGRAMMABLE SENSOR CONTROLLER TX9042 COMPLETE VERSATILITY OF UNDERGROUND SENSOR MANAGEMENT & DATA COMMUNICATIONS ATEX Gas sensors, flow sensors, pressure sensors, vibration monitoring, temperature devices,
More informationSTT 3000 Series STT170 SMART TEMPERATURE TRANSMITTER Models STT171, STT173, STT17H, STT17F, STT17C
STT 3000 Series STT170 SMART TEMPERATURE TRANSMITTER Models STT171, STT173, STT17H, STT17F, STT17C 6/07 PRODUCT SPECIFICATION SHEET OVERVIEW The Honeywell STT170 series of programmable temperature transmitters
More informationIn-Line Resistance Thermometers Model TR25
Electrical Temperature Measurement In-Line Resistance Thermometers Model TR25 WIKA Data Sheet TE 60.25 Applications Food and beverage industry, dairies, drink dispensers and bottling plants, breweries
More informationTemperature Transmitters - DIN Rail Mounted
XTD Features - Non-programmable Models Sensor Types: Models for thermocouple Types J, K, or T Models for RTD Type Pt100 3-wire Select from a variety of pre-configured measuring ranges Internal cold junction
More informationResistance thermometers for process technology
Data Sheet 90.2820 Page 1/8 Resistance thermometers for process technology for temperatures from -200 to +600 C with protection tubes in stainless steel, titanium, tantalum, Iconel and Hastelloy available
More informationph or ORP Transmitter
ph or ORP Transmitter Programmable outputs: two transistor and single or dual analog 4-20 ma (Process + Temp) Removable backlighted display Universal process connection Compatible with 120 mm ph/ ORP probes
More informationElectromagnetic Flow Transmitter
Electromagnetic Flow Transmitter Sensor in solid state technology Working as a transmitter and/or as an On/Off controller Automatic-calibration of full scale: Teach-In Clean in place (CIP) Type can be
More information2-WiRE LEvEL TRansmiTTER PRELEvEL 5343 ConTEnTs
2-wire level transmitter PRelevel 5343 Contents EC declaration of conformity... 14 Application... 15 Technical characteristics... 15 Mounting / installation... 15 Applications... 16 Electrical specifications...
More informationTemperature Sensor with Thread G1/4" FLEXadapt
SENSORS FOR FOOD AND BIOPHARMA. Product Information TFP-414, -614, -814 FOOD Temperature Sensor with Thread G1/4" FLEXadapt Application/Specified usage Temperature measurement in weld-in thermowells and
More informationRosemount 3101, 3102, and 3105
Product Data Sheet February 2013 00813-0100-4840, Rev DA Rosemount 3101, 3102, and 3105 Ultrasonic Liquid Level Transmitters Non-contacting measurement with no moving parts Integral LCD and buttons as
More informationAnalogue temperature transmitter Model T91.10, head mounting version DIN form B Model T91.20, head mounting version form J
Electrical temperature measurement Analogue temperature transmitter Model T91.10, head mounting version DIN form B Model T91.20, head mounting version form J WIKA data sheet TE 91.01 for further approvals
More informationISOLATED 4-20 ma TRANSMITTERS
500 SERIES FOR DEMANDING APPLICATIONS Isolated to 1500 V rms Two-Wire 4-20 ma Operation 9-50 V Compliance Turndown Ratio to 10:1 NMV Protection to 120 Vac -40 to +85 C (-40 to 185 F) Operation Shock Resistance
More informationOPTIWAVE 1010 Technical Datasheet
OPTIWAVE 1010 Technical Datasheet Radar (FMCW) Level Transmitter for bypass chambers and magnetic level indicators (BM 26 Advanced) Device welded to a bypass chamber with an optional IP68 level indicator
More informationTRONIC Digest. TRONIC Digest Pressure and Temperature Transmitters
TRONIC Digest TRONIC Digest Pressure and Temperature Transmitters R Industrial & Hazardous Transmitters Standard Industrial S-10 These rugged pressure transmitters are designed for use in harsh environments
More informationTarget disk flowmeter for liquids and gases
Target disk flowmeter for liquids and gases Metallic, simple and robust construction Available for all flow directions Suitable for extreme pressure and temperature conditions Low pressure drop Straight
More informationThe transducer component converts the measured signal and displays the actual value.
Digital inductive conductivity transmitter System Integration Provides low Total Cost of Ownership PEEK/PPA version for CIP applications TEACH IN and SIMULATION Function Approval PVDF Version PEEK Version
More informationIndustrial Interface The Signal Conditioning People
Loop Powered Products including: 420TW 420i RTD/TC-HEAD Isolating Terminal Blocks Loop Powered Isolators In-Head Transmitters DC/AC Powered Isolation including: ISOCON DUALCON SLIMCON TC-TC VCON STRAIN
More information