1 DATASHEET D012 FLOW RATE INDICATOR / TOTALIZER FLOW RATE INDICATOR / TOTALIZER DISPLAYS FLOW RATE AND TOTAL SIMULTANEOUSLY DSeries advantages Unique, robust IP66, IP67 (NEMA4X) panel mount front enclosure made of die cast aluminum, allowing even big jets of water and total immersion. Programming can be done by your own crew with the exact same, plain and sensible menudriven structure like the FSeries, saving cost and irritation. Know one, know them all! Features Displays flow rate, total and accumulated total. Large 17mm (0.67") digits for flow rate or total. Selectable onscreen engineering units. Ability to process all types of flowmeter signals. Auto backup of settings and running totals. Operational temperature 40 C up to 80 C (40 F up to 176 F). LED backlight option. Input loop powered, battery powered or 8 30V DC, 24V AC and V AC. Sensor supply 1.2 / 3 / DC. input Flow Reedswitch. NAMUR. NPN/PNP. Sine wave (coil). Active signals. (0)4 20mA. 0 10V DC. Applications The DSeries is a DINsized display and the better alternative for your existing, not waterproof, front panel mount indicators in extreme weather outdoor applications or e.g. in food industries where working environments are often cleaned with powerful water jets. The D012 fits in flow measurement applications where a local flow rate indication and totalizer function is required without retransmission functionality. Alternative basic models D010 and D011 or more advanced D013, D014, D016 or the FSeries flow rate indicators. 1

2 General information Introduction The D012 is a local, panel mount indicator to display the actual flow rate, total and accumulated total. The total can be reset to zero by pressing the CLEAR button twice. The eleven digit accumulated total however can not be reset to zero. The measuring unit to be displayed is simply selected through an alfanumerical configuration menu. No adhesive labels have to be put on the outside of the enclosure: a weather proof and userfriendly solution! Display The display has large 17mm (0.67 ) and 8mm (0.31 ) digits which can be set to show flow rate and / or totals. Onscreen engineering units are easily configured from a comprehensive selection. The accumulated total can register up to 11 digits and is backedup in EEPROM memory every minute, just as the running total. The display is a transflective type, which means that a high contrast reading is guaranteed, even in full sunlight. The D012 has a smart display update function incorporated. Related to the lower temperatures, the update frequency of the LCD is tuned automatically to achieve a readable display even at 40 C / 40 F. Backlight For those applications where readability during day and night is an issue, a bicolor backlight is available. The background color can be set to green or amber and the intensity can be adjusted in the configuration menu. input The D012 accepts most and analog input signals for volumetric flow or mass flow measurement. The input signal type can be selected by the user in the configuration menu without having to adjust any sensitive mechanical dipswitches, jumpers or trimmers. The analog input version is even available as 4 20mA input loop powered display. The basic power supply for the D012 is 8 30V DC. Several other power supplies are available: With the 24V AC/DC and V AC power supplies, an DC sensor supply is offered. For analog sensors, a 4 20mA input loop powered version is available. Finally we offer a long life lithium battery with a life expectancy that will last up to five years. Enclosure The D012 is supplied in a unique, robust IP66, IP67 (NEMA4X) class panel mount front enclosure made of die cast aluminum, based on a popular DIN sized enclosure of 144 x 72mm. The front enclosure withstands powerful water jets and even total immersion. The maximum thickness of the panel is 6mm ( 1 /4"). The DSeries is the better alternative for your existing, not waterproof, front panel mounted indicators. Overview application D012 Configuration All configuration settings are accessed via a simple operator menu which can be passcode protected. Each setting is clearly indicated with an alphanumerical description, which avoids confusing abbreviations and baffling codes. Once familiar with one Dseries product, you will be able to program all models in all series without a manual. All settings are safely stored in EEPROM memory in the event of sudden power failure. Flowmeter input 2 D012

3 Dimensions enclosure Terminal connections D (2.83 ) (0.63 ) 55,4 (2.18 ) MAINS POWER SUPPLY PD: 24V AC P1 PM: V AC P2 PM / PD: If an AC power supply is connected to P1P2, then a 24V DC output is available on P4. WARNING: DON T CONNECT A 24V DC (P3P4) AND A 24V AC (P1P2) AT THE SAME TIME! P: coil SENSOR INPUT & SUPPLY S1 S2 S3 S4 P: reed switch / NPN P: active signal 3V P: PNP 3V P: namur 3V A: (0)4 20mA I U: 0 10V U : The sensor supply (S4) is only available with PD, PM. POWER SUPPLY P3 P4 PD: 24V DC PX: 8 30V DC PB: battery powered (PX is also available: if an external supply is connected, the battery supply will be switched off / on automatically.) ZB: 20 30V DC HART COMMUNICATION PENDING A1 PX, PL or PB: If option ZB ordered, than 20 30V DC must be connected to terminal P3, P4. A2 A PL: 4 20mA PL: input loop powered. I 144 (5.67 ) 67,2 (2.65 ) Display example 90 x 40mm (3.5" x 1.6") (5.40 ) Dimensions according DIN / IEC Dimensions panel cutout 138 (5.43 ) 68 (2.68 ) Maximum panel thickness: 6mm ( 1 /4 ) D012 3

4 Wiring diagram D012PPB(PX)(ZB) Wiring diagram D012APX(ZB) Wiring diagram D012PPDZB Type PB: BATTERY POWERED Type PX: BASIC 8 30V DC POWER SUPPLY (STANDARD) Type PD: 24V AC POWER SUPPLY type PX: 8 30V DC and Backlight option type ZB: 20 30V DC (both not used in this example) Backlight option type ZB: 20 30V DC (not used in this example) type PX: 8 30V DC type A: (0)4 20mA 8 30V DC 24V DC Supply Backlight option type ZB: Internally powered. NOTE: Do NOT supply the backlight on P3 / P4. type PD: 24V DC (Can not be used in this example!) Terminal S3: not available. Wiring diagram D012APLZB Wiring diagram D012PPDZB Wiring diagram D012PPMZB Type PD: 24V DC POWER SUPPLY type PD: 24V AC WARNING: DON T CONNECT A 24V DC (P3P4) AND A 24V AC (P1P2) AT THE SAME TIME! 24V AC Terminal S4: DC. Terminal S4: DC. Type PM: V AC POWER SUPPLY Backlight option: type ZB Internally powered. type PD: 24V DC 24V DC 24V DC Supply Terminal S3: not available. Type PL: INPUT LOOP POWERED Backlight supply Backlight option: type ZB type A PL: Input loop powered 4 20mA 20 30V DC 8 30V DC Backlight option type ZB: Internally powered. NOTE: Do NOT supply the backlight on P3 / P4. type PD: 24V AC (Can not be used in this example!) WARNING: DON T CONNECT A 24V DC (P3P4) AND A 24V AC (P1P2) AT THE SAME TIME! Mains supply type PM: V AC L1 N Sensor supply: sensor is externally powered. Terminal S4: DC. Terminal S4: DC. Terminal S4: DC. Terminal S4: DC. 4 D012

5 Technical specification General Display Type High intensity reflective numeric and alphanumeric LCD, UVresistant. Dimensions 90 x 40mm (3.5" x 1.6"). Seven 17mm (0.67") and eleven 8mm (0.31") digits. Various symbols and measuring units. Refresh rate User definable: fast, 1sec, 3sec, 15sec, 30sec, off. Option ZB Transflective LCD with bicolor LEDbacklight; green / amber. Intensitiy and color can be adjusted in the configuration menu. Good readings in full sunlight and darkness. Operating temperature Standard unit 40 C to 80 C (40 F to 176 F). Environment Electromagnetic Compliant ref: EN (1997), EN (1993). compatibility Power requirements Type PB Long life Lithium battery lifetime depends upon settings and configuration up to 5 years. Type PD 24V AC/DC ± 10%. Power consumption max. 1 Watt. Type PL Input loop powered from sensor signal 4 20mA (requires type A). Type PM V AC ± 10%. Power consumption max. 1 Watt. Type PX 8 30V DC. Power consumption max. 0.3 Watt. Type ZB 20 30V DC. Power consumption max. 1 Watt. With type PD / PM: internally powered. Sensor excitation Type PB/PX 3V DC for signals and 1.2V DC for coil pickup. This is not a real sensor supply. Only suitable for sensors with a very low power consumption like coils (sine wave) and reedswitches. Type PD / PM for signals: 1.2 / 3 / DC For analog signals: DC 8.2V DC, Iout max. 20 C. 12V DC, Iout max. 20 C. 24V DC, Iout max. 20 C. (this voltage can vary depending on the input supply voltage) Terminal connections Type Removable plugin terminal strip. Wire max. 1.5mm 2 and 2.5mm 2. Data protection Type EEPROM backup of all settings. Data retention at least 10 years. Passcode Configuration settings can be passcode protected. Casing General Window Sealing Control keys Polycarbonate window. Silicone. Three industrial microswitch keys. UVresistant silicone keypad. Panel mount enclosure Dimensions 144 x 72 x 71.4mm (5.67" x 2.83" x 2.81") W x H x D according DIN / IEC Panel cutout 138 x 68mm (5.43" x 2.68") L x H. Material Diecast aluminum front panel GRP back enclosure Protection IP66, IP67 (NEMA 4X) at the frontside. Weight 325 gr. Panel thickness Max. 6mm ( 1 /4 ). input Flowmeter sensor Type P Coil / sine wave (minimum 20mVpp or 80mVpp sensitivity selectable), NPN/PNP, open collector, reedswitch, Namur, active signals V DC. Frequency Minimum 0Hz maximum 7kHz for total and flow rate. Maximum frequency depends on signal type and internal lowpass filter. E.g. reed switch with lowpass filter: max. frequency 120Hz. KFactor ,999,999 with variable decimal position. Lowpass filter Available for all signals. Option ZF coil sensitivity 10mVpp. Option ZG coil sensitivity 5mVpp. Type A (0)4 20mA. Analog input signal can be scaled to any desired range within 0 20mA. Type U 0 10V DC. Analog input signal can be scaled to any desired range within 0 10V DC. Accuracy Resolution: 16 bit. Error < 0.01mA / ± 0.05% FS. Low level cutoff programmable. Span / 999,999 with variable decimal position. Update time Four times per second. Voltage drop Type A: max. 1V 20mA. Voltage drop Type A PL (loop powered): max. 2.6V 20mA. Load impedance Type U: 3kΩ. Relationship Linear and square root calculation. For signal type A and U: external power to sensor is required; e.g. type PD / PM. Operational Operator functions Displayed Flow rate and / or total. functions Total and accumulated total. Total can be reset to zero by pressing the CLEARkey twice. Total 7 digits. Units L, m 3, GAL, USGAL, kg, lb, bbl, no unit. Decimals or 3. Total can be reset to zero. Accumulated total 11 digits. Units / decimals According to selection for total. Can not be reset to zero. Flow rate Units 7 digits. ml, L, m 3, Gallons, kg, Ton, lb, bl, cf, RND, ft 3, scf, Nm 3, Nl, igal no units. Decimals or 3. Time units /sec /min /hr /day. D012 5

6 Ordering information Standard configuration: D012PHBPXZX. ordering information: D012 _ HB P _ Z _ signal A (0)4 20mA input. P Pulse input: coil, npn, pnp, namur, reedswitch. U 0 10V DC input. Panel mount front enclosure IP66, IP67 (NEMA4X) HB Aluminum DIN / IEC front panel. PB Lithium battery powered. PD 24V AC / DC sensor supply. PL Input loop powered from sensor signal 4 20mA requires type A. PM V AC sensor supply. PX Basic power supply 8 30V DC (no real sensor supply). Other options ZB Backlight. ZF Coil input 10mVpp requires type P. ZG Coil input 5mVpp requires type P. ZX No options. The bold marked text contains the standard configuration. Specifications are subject to change without notice. Fluidwell bv P.O. Box AA Veghel The Netherlands Telephone: 31 (0) Telefax: 31 (0) displays@fluidwell.com Internet: 6 Copyright: Fluidwell bv 2013 D012DATAENV1326

BATCH CONTROLLER DATASHEET D030 - BATCH CONTROLLER WITH ONE STAGE CONTROL

BATCH CONTROLLER DATASHEET D030 - BATCH CONTROLLER WITH ONE STAGE CONTROL BATCH CONTROLLER WITH ONE STAGE CONTROL DATASHEET D030 BATCH CONTROLLER DSeries advantages Unique, robust IP66, IP67 (NEMA4X) panel mount front enclosure made of die cast aluminum, allowing even big jets

More information

GENERAL PURPOSE INDICATOR LOOP POWERED WITH VERY LARGE DIGITS DATASHEET F090 - GENERAL PURPOSE INDICATOR

GENERAL PURPOSE INDICATOR LOOP POWERED WITH VERY LARGE DIGITS DATASHEET F090 - GENERAL PURPOSE INDICATOR GENERAL PURPOSE INDICATOR LOOP POWERED WITH VERY LARGE DIGITS DATASHEET F090 - GENERAL PURPOSE INDICATOR Features Universal loop powered indicator. Very large 26mm (1 ) high digits. Displays the actual

More information

DATASHEET F010 - FLOW RATE INDICATOR

DATASHEET F010 - FLOW RATE INDICATOR FLOW RATE INDICATOR WITH VERY LARGE DIGITS DATASHEET F010 FLOW RATE INDICATOR Advantages Robust IP66, IP67 (NEMA4X) field enclosure. It is so rugged, you can even stand on it! Intrinsically Safe available

More information

Flow rate Indicator / Totalizer

Flow rate Indicator / Totalizer Datasheet ER100(M) Robust explosion proof indicator Flow rate Indicator / Totalizer with linearization, analog and pulse signal outputs Advantages Save time and gain flexibility with the easytooperate

More information

Flow Monitor / Totalizer with linearization, high / low alarms, analog and pulse signal outputs and HART Communication

Flow Monitor / Totalizer with linearization, high / low alarms, analog and pulse signal outputs and HART Communication Datasheet E018 Robust explosion proof indicator Reliable Flow Monitor / Totalizer with linearization, high / low alarms, analog and pulse signal outputs and HART Communication Advantages Save time and

More information

DATASHEET F110 - FLOW RATE INDICATOR / TOTALIZER

DATASHEET F110 - FLOW RATE INDICATOR / TOTALIZER FLOW RATE INDICATOR / TOTALIZER WITH ANALOG AND PULSE SIGNAL OUTPUTS DATASHEET F110 FLOW RATE INDICATOR / TOTALIZER Advantages Robust IP67 (NEMA4X) field enclosure. It is so rugged, you can even stand

More information

DATASHEET F110 - FLOW RATE INDICATOR / TOTALIZER

DATASHEET F110 - FLOW RATE INDICATOR / TOTALIZER FLOW RATE INDICATOR / TOTALIZER WITH ANALOG AND PULSE SIGNAL OUTPUTS DATASHEET F110 FLOW RATE INDICATOR / TOTALIZER Advantages Robust IP67 (NEMA Type4X) field enclosure. It is so rugged, you can even stand

More information

DATASHEET F090 - GENERAL PURPOSE INDICATOR

DATASHEET F090 - GENERAL PURPOSE INDICATOR GENERAL PURPOSE INDICATOR LOOP POWERED WITH VERY LARGE DIGITS DATASHEET F090 - GENERAL PURPOSE INDICATOR Features Universal loop powered indicator. Very large 26mm (1 ) high digits. Displays the actual

More information

BATCH CONTROLLER WITH TWO STAGE CONTROL / PULSE AND ANALOG OUTPUT IN RELATION TO THE FLOW RATE DATASHEET F131 - BATCH CONTROLLER

BATCH CONTROLLER WITH TWO STAGE CONTROL / PULSE AND ANALOG OUTPUT IN RELATION TO THE FLOW RATE DATASHEET F131 - BATCH CONTROLLER BATCH CONTROLLER WITH TWO STAGE CONTROL / PULSE AND ANALOG OUTPUT IN RELATION TO THE FLOW RATE DATASHEET F131 BATCH CONTROLLER Features Large display shows preset value, running batch value and instantaneous

More information

FLOW RATE INDICATOR / TOTALIZER DATASHEET F112 - FLOW RATE INDICATOR / TOTALIZER

FLOW RATE INDICATOR / TOTALIZER DATASHEET F112 - FLOW RATE INDICATOR / TOTALIZER DATASHEET F112 FLOW RATE INDICATOR / TOTALIZER FLOW RATE INDICATOR / TOTALIZER WITH LINEARIZATION AND ANALOG / PULSE SIGNAL OUTPUTS Advantages Robust IP67 (NEMA Type4X) field enclosure. It is so rugged,

More information

FLOW RATE MONITOR / TOTALIZER

FLOW RATE MONITOR / TOTALIZER FLOW RATE MONITOR / TOTALIZER WITH HIGH / LOW ALARM, ANALOG AND PULSE SIGNAL OUTPUTS DATASHEET F113 FLOW RATE MONITOR Advantages Robust IP67 (NEMA4X) field enclosure. It is so rugged, you can even stand

More information

TOTALIZER MONITOR DATASHEET F117 - TOTALIZER MONITOR WITH HIGH / LOW TOTALIZER ALARM AND ANALOG SIGNAL OUTPUT

TOTALIZER MONITOR DATASHEET F117 - TOTALIZER MONITOR WITH HIGH / LOW TOTALIZER ALARM AND ANALOG SIGNAL OUTPUT TOTALIZER MONITOR WITH HIGH / LOW TOTALIZER ALARM AND ANALOG SIGNAL OUTPUT DATASHEET F117 TOTALIZER MONITOR Features The desired totalized (preset) quantity can be set by the operator Reset totalizer:

More information

FLOW RATE INDICATOR / TOTALIZER DATASHEET F112 - FLOW RATE INDICATOR / TOTALIZER

FLOW RATE INDICATOR / TOTALIZER DATASHEET F112 - FLOW RATE INDICATOR / TOTALIZER DATASHEET F112 FLOW RATE INDICATOR / TOTALIZER FLOW RATE INDICATOR / TOTALIZER WITH LINEARIZATION AND ANALOG / PULSE SIGNAL OUTPUTS Advantages Robust IP66, IP67 (NEMA4X) field enclosure. It is so rugged,

More information

BATCH CONTROLLER WITH TWO STAGE CONTROL / PULSE OUTPUT DATASHEET F130 - BATCH CONTROLLER

BATCH CONTROLLER WITH TWO STAGE CONTROL / PULSE OUTPUT DATASHEET F130 - BATCH CONTROLLER BATCH CONTROLLER WITH TWO STAGE CONTROL / PULSE OUTPUT DATASHEET F130 BATCH CONTROLLER Features Large display shows preset value and running batch value simultaneously. Selflearning overrun correction.

More information

FLOW RATE MONITOR / TOTALIZER

FLOW RATE MONITOR / TOTALIZER FLOW RATE MONITOR / TOTALIZER WITH HIGH / LOW ALARM, ANALOG AND PULSE SIGNAL OUTPUTS DATASHEET F113 FLOW RATE MONITOR Features Displays instantaneous flow rate, total and accumulated total. Four alarm

More information

FLOW RATE MONITOR / TOTALIZER

FLOW RATE MONITOR / TOTALIZER FLOW RATE MONITOR / TOTALIZER WITH HIGH / LOW ALARM, ANALOG AND PULSE SIGNAL OUTPUTS DATASHEET F113 FLOW RATE MONITOR Advantages Robust IP67 (NEMA Type4X) field enclosure. It is so rugged, you can even

More information

BATCH CONTROLLER DATASHEET F130 - BATCH CONTROLLER WITH TWO STAGE CONTROL / PULSE OUTPUT

BATCH CONTROLLER DATASHEET F130 - BATCH CONTROLLER WITH TWO STAGE CONTROL / PULSE OUTPUT BATCH CONTROLLER WITH TWO STAGE CONTROL / PULSE OUTPUT DATASHEET F130 BATCH CONTROLLER Advantages Robust IP66, IP67 (NEMA4X) field enclosure. It is so rugged, you can even stand on it! Intrinsically Safe

More information

FLOW RATE INDICATOR / TOTALIZER DATASHEET F112 - FLOW RATE INDICATOR / TOTALIZER

FLOW RATE INDICATOR / TOTALIZER DATASHEET F112 - FLOW RATE INDICATOR / TOTALIZER DATASHEET F112 FLOW RATE INDICATOR / TOTALIZER FLOW RATE INDICATOR / TOTALIZER WITH LINEARISATION AND ANALOG / PULSE SIGNAL OUTPUTS Features Displays instantaneous flow rate, total and accumulated total.

More information

BATCH CONTROLLER DATASHEET F131 - BATCH CONTROLLER WITH TWO STAGE CONTROL / PULSE AND ANALOG OUTPUT IN RELATION TO THE FLOW RATE

BATCH CONTROLLER DATASHEET F131 - BATCH CONTROLLER WITH TWO STAGE CONTROL / PULSE AND ANALOG OUTPUT IN RELATION TO THE FLOW RATE BATCH CONTROLLER WITH TWO STAGE CONTROL / PULSE AND ANALOG OUTPUT IN RELATION TO THE FLOW RATE DATASHEET F131 BATCH CONTROLLER Advantages Robust IP67 (NEMA Type4X) field enclosure. It is so rugged, you

More information

BATCH CONTROLLER DATASHEET F130 - BATCH CONTROLLER WITH TWO STAGE CONTROL / PULSE OUTPUT

BATCH CONTROLLER DATASHEET F130 - BATCH CONTROLLER WITH TWO STAGE CONTROL / PULSE OUTPUT BATCH CONTROLLER WITH TWO STAGE CONTROL / PULSE OUTPUT DATASHEET F130 BATCH CONTROLLER Advantages Robust IP67 (NEMA Type4X) field enclosure. It is so rugged, you can even stand on it! Intrinsically Safe

More information

DATASHEET F120 - FLOW RATE CONTROLLER

DATASHEET F120 - FLOW RATE CONTROLLER FLOW RATE CONTROLLER WTH ANALOG CONTROL OUTUT AND HGH / LOW ALARMS DATASHEET F120 FLOW RATE CONTROLLER Advantages Robust 67 (NEMA Type4X) field enclosure. t is so rugged, you can even stand on it! ntrinsically

More information

RATIO CONTROLLER DATASHEET F124 - RATIO CONTROLLER WITH ANALOG CONTROL OUTPUT AND HIGH / LOW ALARMS

RATIO CONTROLLER DATASHEET F124 - RATIO CONTROLLER WITH ANALOG CONTROL OUTPUT AND HIGH / LOW ALARMS RATO CONTROLLER WTH ANALOG CONTROL OUTUT AND HGH / LOW ALARMS DATASHEET F124 RATO CONTROLLER Advantages Robust 67 (NEMA Type4X) field enclosure. t is so rugged, you can even stand on it! ntrinsically Safe

More information

Flowcomputer for Corrected Liquid Volume

Flowcomputer for Corrected Liquid Volume Flowcomputer for Corrected Liquid Volume Owner s Manual Model F126-P Signal input flowmeter - type P: pulse, Namur and coil Signal input pressure - type IA: (0)4-20mA Signal input temperature - type TP:

More information

Electronic Data Devices

Electronic Data Devices Calibration for EDD800 Totalizer Hold PROG/ENTER for 7 seconds Electronic Data Devices Odessa, Texas USA 432-366-8699 rkw@eddevices.com EDD800 CALIBRATION INSTRUCTIONS Setup 1 - Setup 11 - Setup 12 - Setup

More information

F-SERIES FOR. Indicators Totalizers Transmitters Flow computers Batch controllers Monitors. Flow Level Pressure Temperature

F-SERIES FOR. Indicators Totalizers Transmitters Flow computers Batch controllers Monitors. Flow Level Pressure Temperature F-SERIES Indicators Totalizers Transmitters Flow computers Batch controllers Monitors Flow Level Pressure Temperature FOR F - SERIES F - SERIES F - SERIES F - SERIES F - SERIES F - SERIES F - SERIES F

More information

Operating Instructions 12/2007 SITRANS F RA 110 ATEX. Intrinsically-safe flowrate indicator/totalizer. flow

Operating Instructions 12/2007 SITRANS F RA 110 ATEX. Intrinsically-safe flowrate indicator/totalizer. flow Operating Instructions 12/2007 Intrinsically-safe flowrate indicator/totalizer flow SITRANS F Flowmeters Intrinsically-safe flowrate indicator/totalizer Operating Instructions (Compact) Introduction Safety

More information

Dial-type digital bar graph. LEDs for Open Collector, Relays and Warning Indicator

Dial-type digital bar graph. LEDs for Open Collector, Relays and Warning Indicator Specifications General Input Channels One Input Types Digital (S 3 L) Serial ASCII, TTL level, 9600 bps Frequency Range 0.5 to 1500 Hz Accuracy 0.5% of reading Measurement Types Flow, ph/orp, Conductivity/Resis

More information

Signet 9900 Transmitter

Signet 9900 Transmitter Signet 9900 Transmitter Member of the SmartPro Family of Instruments Features Multiple sensor types supported with one instrument Dial-type digital bar graph Modules are field installable and replaceable

More information

SITRANS F flowmeters SITRANS F M. Transmitter Transmag 2 with sensor 911/E 4/77. Overview

SITRANS F flowmeters SITRANS F M. Transmitter Transmag 2 with sensor 911/E 4/77. Overview Overview Design The complete flowmeter consists of a flow sensor and an associated transmitter from the Transmag 2 for pulsed alternating field. These are available as remote and compact versions ( 911/E

More information

Signet 9900 Transmitter

Signet 9900 Transmitter Signet 9900 Transmitter Member of the SmartPro Family of Instruments Features Field Mount Multi-Parameter input selection Large auto-sensing backlit display with at a glance visibility Dial-type digital

More information

FIELD MOUNTED RATE TOTALISER MODEL 202D

FIELD MOUNTED RATE TOTALISER MODEL 202D FIELD MOUNTED RATE TOTALISER MODEL 202D 1 February 1999 CONTENTS 1. Introduction 1 1.1 Model Number Designation 3 1.2 Intrinsic Safety Considerations 4 2. Specification 6 3. Operation 8 3.1 Display 8

More information

5-Digit Dual-line explosion-proof pulse input rate/totalizer

5-Digit Dual-line explosion-proof pulse input rate/totalizer 5-Digit Dual-line explosion-proof pulse input rate/totalizer TM RTP OUCH Through-Glass Button Programming protex-rtp Model pd6830 Pulse, Open Collector, NPN, PNP, TTL, Switch Contact, Sine Wave (Coil),

More information

Signet 9900 Transmitter

Signet 9900 Transmitter Signet 9900 Transmitter Member of the SmartPro Family of Instruments Features Panel Mount Field Mount Multi-Parameter input selection Large auto-sensing backlit display with at a glance visibility Dial-type

More information

Signet 9950 Dual Channel Transmitter

Signet 9950 Dual Channel Transmitter Signet 9950 Dual Channel Transmitter Member of the SmartPro Family of Instruments Features One instrument for multiple sensor types Multiple language support for (Gen 2a) or later in Simplified Chinese,

More information

Count/Time Totalizers

Count/Time Totalizers /Time Totalizers Compact or Time Totalizers with Easy-to-Read and NEMA 4 Protection High-visibility, 8.5 mm negative transmissive LCD. NEMA 4 when used in conjunction with Y92S-32 rubber gasket supplied

More information

Signet 9900 Transmitter

Signet 9900 Transmitter Signet 9900 Transmitter Member of the SmartPro Family of Instruments Features Panel Mount Field Mount Multi-Parameter input selection Large auto-sensing backlit display with at a glance visibility Dial-type

More information

Multifunctional counter tico 772/773/774

Multifunctional counter tico 772/773/774 Universally applicable as a tachometer, timer, shift counter, batch counter Easy to operate Four different backlight colours Intensity of backlighting can now be adjusted Large, clearly readable 48 x 48

More information

1) What meter do I need in this application?

1) What meter do I need in this application? ELECTRONIC ELECTRONIC Choices 1) What meter do I need in this application? Meter choice is determined by: Level of accuracy required, flowrate, line size, viscosity, fitting type, pressure rating, temperature,

More information

INSTALLATION & OPERATION MANUAL

INSTALLATION & OPERATION MANUAL INSTALLATION & OPERATION MANUAL AN25 Totalizer/ Rate Indicator DOC#: MN-AN25.doc Sponsler Co., Inc. AN25 Totalizer/Rate Indicator pg. 2 DOC#: MN-AN25 SPECIFICATIONS Temperature: Operating 0 to 70 C Storage

More information

BATCHMATE 1500 Batch Control Computer Technical Bulletin

BATCHMATE 1500 Batch Control Computer Technical Bulletin TS-5(C) BATCHMATE 5 Batch Control Computer Technical Bulletin DESCRIPTION The BATCHMATE features an 8 digit.55-in. alphanumeric LED display. The pulse input model will accept up to 2, pulses per second

More information

SITRANS F flowmeters SITRANS F US. Transmitter FUS060. Overview

SITRANS F flowmeters SITRANS F US. Transmitter FUS060. Overview Overview Function Displays and keypad Operation of the SITRANS FUS060 transmitter can be carried out using: Keypad and display unit HART communicator PC/laptop and SIMATIC PDM software via HART communication

More information

Signet 9900 Transmitter

Signet 9900 Transmitter Signet 9900 Transmitter Member of the SmartPro Family of Instruments Features Panel Mount Field Mount NEW! Modbus Module supports RS485 Serial Modbus Communications Multiple sensor types supported with

More information

Signet 9900 Transmitter

Signet 9900 Transmitter Signet 9900 Transmitter Member of the SmartPro Family of Instruments Features Panel Mount Field Mount Multi-Parameter input selection Large auto-sensing backlit display with at a glance visibility Dial-type

More information

Signet 9950 Dual Channel Transmitter

Signet 9950 Dual Channel Transmitter Signet 9950 Dual Channel Transmitter Member of the SmartPro Family of Instruments Features One instrument for multiple sensor types Multiple language support for Simplified Chinese, English, French, German

More information

Advanced Ladder Logic Full IEC Languages 25A for <1 24 VDC DC Switched

Advanced Ladder Logic Full IEC Languages 25A for <1 24 VDC DC Switched EXL6 OCS Datasheet for HE- EXL1E0, HE- EXL1E2, HE- EXL1E3, HE- EXL1E4, HE- EXL1E5, HE- EXL1E6 HEXT371C100, HEXT371C112, HEXT371C113, HEXT371C114, HEXT371C115, HEXT371C116 1. Specifications Required Power

More information

Technical data. Functional safety related parameters MTTF d. Transfer characteristics. Time delay before availability. Standard conformity

Technical data. Functional safety related parameters MTTF d. Transfer characteristics. Time delay before availability. Standard conformity KFU8-DW-.D Release date: 2-2- 2:8 Date of issue: 26-8- 4_eng.xml Model Number KFU8-DW-.D Rotation Speed Monitor Features Speed monitoring up to 4 khz pre-select value with relay output and LED indicator

More information

RATE / TOTAL / BATCH METERS INF7

RATE / TOTAL / BATCH METERS INF7 RATE / TOTAL / BATCH METERS INF7 Rate and Total Simultaneously Batch Controller Real-Time Clock Square Root Programmable Isolated BCD Option Isolated analog input Option 5 Open Collector Outputs Standard

More information

Flow - Rotor. Characteristics. Applications. Mechanical-magnetical, Infrared. Quantity measurement for filling processes

Flow - Rotor. Characteristics. Applications. Mechanical-magnetical, Infrared. Quantity measurement for filling processes GHM Messtechnik GmbH Hans-Sachs-Str. 26 93128 Regenstauf Germany Fon +49 (0) 9402-9383 - 0 Fax +49 (0) 9402-9383 33 www.ghm-messtechnik.de info@ghm-messtechnik.de Flow - Rotor Characteristics Applications

More information

Supercal 531 Multi function Integrator that lives up to Your highest expectations

Supercal 531 Multi function Integrator that lives up to Your highest expectations n Thermal Energy n Flow Metering n Supercal 531 Multi function Integrator that lives up to Your highest expectations Supercal 531 Multi functional integrator with unlimited options The Supercal 531 convinces

More information

Count - counters 5. Selection guide 5 XBK T81030U33E RC XBK RC XBK T60000U00M XBK T60000U11M XBK T80000U00M XBK T70000U00M 5/2

Count - counters 5. Selection guide 5 XBK T81030U33E RC XBK RC XBK T60000U00M XBK T60000U11M XBK T80000U00M XBK T70000U00M 5/2 Selection guide Count - counters Function Totalising counters Display type Mechanical LCD Font panel dimensions (h x w) in mm 0 x 0 x. 0 x 60 x Number of display digits 6 digits or 6 digits (depending

More information

Rosemount Specifications. Product Data Sheet , Rev BA February 2009 PERFORMANCE SPECIFICATIONS

Rosemount Specifications. Product Data Sheet , Rev BA February 2009 PERFORMANCE SPECIFICATIONS Rosemount 2051 Product Data Sheet PERFORMANCE SPECIFICATIONS Specifications For zero based spans, reference conditions, silicone oil fill, SST materials, Coplanar flange () or 1 /2 in. - 14 NPT () process

More information

INSTALLATION & OPERATION MANUAL MODEL IT375 FIELD MOUNTED RATE INDICATOR AND TOTALIZER

INSTALLATION & OPERATION MANUAL MODEL IT375 FIELD MOUNTED RATE INDICATOR AND TOTALIZER INSTALLATION & OPERATION MANUAL MODEL IT375 FIELD MOUNTED RATE INDICATOR AND TOTALIZER February 2002 Sponsler, Inc. Model IT375 Contents Pg. 2 CONTENTS 1. Introduction 3 1.1 Model Number Designation 4

More information

Fluke 1740 Series. Three-Phase Power Quality Loggers Memobox. Assess power quality and conduct long-term studies with ease

Fluke 1740 Series. Three-Phase Power Quality Loggers Memobox. Assess power quality and conduct long-term studies with ease Fluke 1740 Series Three-Phase Power Quality Loggers Memobox Technical Data Assess power quality and conduct long-term studies with ease Compact and rugged, the Fluke 1740 Series three-phase power quality

More information

Fluke 1740 Series. Three-Phase Power Quality Loggers Memobox. Assess power quality and conduct long-term studies with ease

Fluke 1740 Series. Three-Phase Power Quality Loggers Memobox. Assess power quality and conduct long-term studies with ease Fluke 1740 Series Three-Phase Power Quality Loggers Memobox Technical Data Assess power quality and conduct long-term studies with ease Compact and rugged, the Fluke 1740 Series three-phase power quality

More information

Though the size is compact, the measurement display uses 4 digit, 8 mm in letter height, red 7-segment LEDs. Letter height 8mm (0.

Though the size is compact, the measurement display uses 4 digit, 8 mm in letter height, red 7-segment LEDs. Letter height 8mm (0. SERIES Ultra-compact Digital Panel Controller CA Convenient s packed in a small body! Ultra-compact Large display Flexible scaling Conforming to EMC Directive Ultra-compact size of W 48 H 24 D 65.5 mm

More information

CURRENT/FREQUENCY CONVERTER S 104

CURRENT/FREQUENCY CONVERTER S 104 CURRENT/FREQUENCY CONVERTER S 104 The S104 complies the electromagnetic compatibility prescriptions based on the 89/366/EEC directive. Reference norms: EN 50081-2 Industry environment emission norm EN

More information

Pulse Scaler for DIN Rail Attachment

Pulse Scaler for DIN Rail Attachment Type 651 Pulse Scaler for DIN Rail Attachment Programmable pulse scaling factor up to 2047:1 NAMUR generator input PNP transistor output Max. pulse frequency 5 khz PROGRAMMING The divisor is set in binary

More information

Introducing GPI s Latest

Introducing GPI s Latest Introducing GPI s Latest Electronic Digital Meter GREAT PLAINS INDUSTRIES, INC. WICHITA, KANSAS CALIBRATE DISPLAY MODEL NON-COMMERCIAL GM SERIES FLOWMETER Total Reset Total New Lockout Feature Lockout

More information

Electro-Magnetic Flowmeters COPA-XE

Electro-Magnetic Flowmeters COPA-XE Data Sheet Electro-Magnetic Flowmeters COPA-XE 10DX4311 Flowmeter system utilizes a smart microprocessor converter System accuracy of ± 0.5% of rate Field configurable via integral pushbuttons, eliminates

More information

SC-FI Series Frequency to Current Signal Conditioner

SC-FI Series Frequency to Current Signal Conditioner SC-FI Series Frequency to Current Signal Conditioner 99829 08/27/01 INDEX DESCRIPTION... 1 SPECIFICATIONS... 1 TYPICAL WIRING HOOKUP... 1 INPUT & OUTPUT SETTINGS... 2 "L" OPTION SPECIFICATIONS... 3 "L"

More information

RI-F200 Series. Single and Three Phase Multifunction Energy Meter. Telephone : +44 (0) Displayed Parameters

RI-F200 Series. Single and Three Phase Multifunction Energy Meter. Telephone : +44 (0) Displayed Parameters RI-F200 Series Single and Three Phase Multifunction Energy Meter DIN 96 panel mounted -/1A or -/5A current transformer input Single phase or three phase network compatible Programmable voltage and current

More information

Digital flow transmitter for continuous flow measurement

Digital flow transmitter for continuous flow measurement Digital flow transmitter for continuous flow measurement Compact or remote version for DN 06 to 400, PN10 Shows both flow rate and volume (with two totalizers) Automatic-calibration: TEACH-IN Simulation:

More information

Digital flowmeter for continuous flow measurement

Digital flowmeter for continuous flow measurement 8025 Flowmeter INSERTION Digital flowmeter for continuous flow measurement Compact or remote version for DN06 to DN400, PN10 Displays both flow rate and volume (with two totalizers) On site calibration

More information

Digital flowmeter for continuous flow measurement

Digital flowmeter for continuous flow measurement 8025 Flowmeter INSERTION Digital flowmeter for continuous flow measurement Compact or remote version for DN06 to DN400, PN10 Displays both flow rate and volume (with two totalizers) On site calibration

More information

PR product range - links to order details and block diagrams

PR product range - links to order details and block diagrams PR product range links to order details and block diagrams 2202 2204 2220 2222 2223 2224 2229 2231 2237 2238 2240 2241 2255 2261 2271 2273 2279 2281 2284 2285 2286 2288 2289 2914 3532 4114 4116 4131 5102

More information

Model Number Structure

Model Number Structure Total Counter/Time Counter (DIN 72 x 36) CSM DS_E_4_1 DIN 72 x 36-mm Total Counter/Time Counter with Easy-to-read Displays and Water and Oil Resistance Equivalent to IP66 Large, easy-to-read displays:

More information

GP-UF/A. Smith Meter Universal F/A Converter. Specifications. Features. Applications. Specifications

GP-UF/A. Smith Meter Universal F/A Converter. Specifications. Features. Applications. Specifications Issue/Rev. 1.6 (8/11) Smith Meter Universal F/A Converter GP-UF/A Specifications Bulletin SS09024 The Smith Meter Model GP-UF/A is a generalpurpose, field-programmable, frequency to analog converter designed

More information

DUK COMPACT ULTRASONIC FLOWMETER

DUK COMPACT ULTRASONIC FLOWMETER DUK COMPACT ULTRASONIC FLOWMETER Flow Pressure Level Temperature Measurement Monitoring Control Measuring Ranges: 0.0- GPM to 0.6-60 GPM Accuracy: ±. % of F.S. Turndown Ratio: 0: P max : 30 PSI; T max

More information

Model FLSC-C1-LIQ. Microprocessor Based Loop Powered Transmitter

Model FLSC-C1-LIQ. Microprocessor Based Loop Powered Transmitter Model FLSC-C1-LIQ Microprocessor Based Loop Powered Transmitter CONTENTS 1. Introduction ------------------------------------------------------------ 2 2. Specifications-----------------------------------------------------------

More information

QL55 Series Luminescence Sensor

QL55 Series Luminescence Sensor Self-contained, microprocessor-based luminescence sensor Features Self-contained design in a robust, compact metal housing High sensitivity Microprocessor-controlled Senses luminescent marks, even on luminescent

More information

Rotational speed controller

Rotational speed controller Model number Features Rotational speed monitoring up to khz pre-select value with relay output and LED indicator Multi-range power pack -, -, -wire and NAMUR sensors as well as rotary encoder connectable

More information

KMS305W. ManuFlo Page 1 MANU ELECTRONICS PTY LTD Flow Measurement Products. Electromagnetic Wafer Flowmeters with S300 display

KMS305W. ManuFlo Page 1 MANU ELECTRONICS PTY LTD Flow Measurement Products. Electromagnetic Wafer Flowmeters with S300 display Electromagnetic Wafer Flowmeters with S300 display for corrosive chemicals/acids & slurries (sizes: 2.5mm to 100mm) 0BFEATURES: For aggressive chemicals, slurries, oxides, grouts & dosing applications

More information

Measurement. SITRANS F US Inline. 3/262 Siemens FI Transmitter SITRANS FUS080/FUE080

Measurement. SITRANS F US Inline. 3/262 Siemens FI Transmitter SITRANS FUS080/FUE080 Overview The transmitter is available in an IP67/NEMA 4X/6 enclosure and is designed for use in the flowmeters series: SONOKIT (1-path or -path) FUS80 (-path) FUE80 (-path) The transmitter FUS080 is always

More information

Microprocessor Gas and Steam Flow Computer Energy Flow Computer (Consumption and Enthalpy for Steam) Series: DigiFlow Type: 515

Microprocessor Gas and Steam Flow Computer Energy Flow Computer (Consumption and Enthalpy for Steam) Series: DigiFlow Type: 515 Microprocessor Gas and Steam Flow Computer Energy Flow Computer (Consumption and Enthalpy for Steam) Series: DigiFlow Type: 515 Technical Information 03/2012 FLOW THE EXPERT IN LEVEL AND FLOW DigiFlow

More information

GEMINI PRESETTABLE DUAL RATE INDICATOR WITH RATIO (A/B)

GEMINI PRESETTABLE DUAL RATE INDICATOR WITH RATIO (A/B) Bulletin No. GEM5-C Drawing No. LP0321 Released 1/05 GEMINI 5200 - PRESETTABLE DUAL RATE INDICATOR WITH RATIO (A/B)! DIFFERENCE (A-B), OR DRAW [(A-B)/B] INDICATION! 6-DIGIT, 0.56" (14.2 mm) HIGH LED DISPLAY

More information

SPECIFICATIONS. Superluminous SunBright display Readable from 100 feet away

SPECIFICATIONS. Superluminous SunBright display Readable from 100 feet away PD2-6000 Helios Process Meter 0-20 ma, 4-20 ma; ±10 VDC (0-5, 1-5, 0-10 V); Modbus PV (slave) Dual-scale for applications 32-point, square root, exponential, or round horizontal tank linearization Tare

More information

Fluke 1623 and GEO Earth Ground Testers. Technical Data. Stakeless testing

Fluke 1623 and GEO Earth Ground Testers. Technical Data. Stakeless testing Fluke 1623 and 1625 GEO Earth Ground Testers Technical Data The new Fluke 1623 and 1625 GEO Earth Ground Testers offer an innovative solution, called Stakeless testing, to make your earth ground loop resistance

More information

MultiCube Multi-Function Electricity Meter. Installation and Operation

MultiCube Multi-Function Electricity Meter. Installation and Operation MultiCube Multi-Function Electricity Meter Installation and Operation PREFACE MultiCube Operating Guide Revision 1.08 Jan 2007 This manual represents your meter as manufactured at the time of publication.

More information

SITRANS F flowmeters SITRANS F US. SONOFLO SONO 3000 transmitter. 4/152 Siemens FI Overview

SITRANS F flowmeters SITRANS F US. SONOFLO SONO 3000 transmitter. 4/152 Siemens FI Overview Overview Design The transmitter is available in different enclosure to fit any demands: IP67 enclosure for compact or wall mounting IP00 as a 19 insert IP65 for wall mounting IP65 enclosure in stainless

More information

Universal process controller econtrol

Universal process controller econtrol Universal process controller Type 8611 can be combined with... Continuous, 2point, 3point and On/Off control Ratio control function Sensor inputs (,, frequency, Pt100) Control of proportional, process

More information

Fluke and

Fluke and Fluke 1623-2 and 1625-2 GEO Earth Ground Testers Technical Data The new Fluke 1623-2 and 1625-2 GEO Earth Ground Testers offer data storage and download capabilities via USB port. World class accessories

More information

Position Indicator with/without Limit Values

Position Indicator with/without Limit Values .1 Position Indicator with/without Limit Values Large, 6-digit, 14 mm high LED display Prescaler 2 variable limit values Eeasy direct selection by 2 function keys Rrelay output with two change-over contacts

More information

Type Nominal voltage (V) Code HSV V

Type Nominal voltage (V) Code HSV V Speed control Speed control relay - mm Control of overspeed, underspeed, operating rate, stopping Measurement via discrete sensors - -wire PNP or NPN, Namur, voltage 0-0V or volt-free contact type Works

More information

IFC 010 Signal Converter

IFC 010 Signal Converter KROHNE 04/2003 7.02347.22.00 GR Signal Converter for electromagnetic flowmeters Easy to install Low-cost signal converter, measuring error < 0.5% of the measured value Easy user-friendly operation Self-monitoring

More information

Light-strip indicator

Light-strip indicator /2 s /2 PROLUX 96 x 24 mm with 5 segments, /6 PROLUX 144 x 24 mm with 101 segments, /10 PROLUX 144 x 6 mm with 71 segments, Siemens MP 12 200 PROLUX 96 x 24 mm with 5 segments, Design The PROLUX light-strip

More information

Model FLSC-C3-XX. DC Powered Microprocessor Controlled Transmitter

Model FLSC-C3-XX. DC Powered Microprocessor Controlled Transmitter Model FLSC-C3-XX DC Powered Microprocessor Controlled Transmitter CONTENTS. Introduction----------------------------------------------------------------- 2 2. Specifications ---------------------------------------------------------------

More information

SHIMADEN DIGITAL INDICATORS

SHIMADEN DIGITAL INDICATORS Shimaden, Temperature and Humidity Control Specialists C %RH Series SD16 & SHIMADEN DIGITAL INDICATORS & NRTL /C approved BASIC FEATURES DIN Size 48 x 96 mm ±.3% High Accuracy Indication Large 2 mm bright

More information

Field IT Electro-Magnetic Flowmeters Mini-Mag with integral XE converter

Field IT Electro-Magnetic Flowmeters Mini-Mag with integral XE converter Data Sheet D-FMP-10D1475W-Y_4 Field IT Electro-Magnetic Flowmeters Mini-Mag with integral XE converter 10D1475W/Y Flowmeter Systems utilizes a smart microprocessor converter. System accuracy of ±0.5% of

More information

TZIF 4. Current-to-Pulse Converter 10/ EN

TZIF 4. Current-to-Pulse Converter 10/ EN TZIF 4 Current-to-Pulse Converter Conversion of direct current or voltage signals into a proportional pulse frequency Integration and average value formation of analog signals for quantity counting/remote

More information

SHIMADEN DIGITAL INDICATORS

SHIMADEN DIGITAL INDICATORS Shimaden, Temperature and Humidity Control Specialists C %RH Series SD16A & SHIMADEN DIGITAL INDICATORS approved,ul applied BASIC FEATURES compliance DIN Size 48 x 96 mm ±.3% High Accuracy Indication Large

More information

Instruction Manual TABLE OF CONTENTS 1 PRINCIPLE OF OPERATION Limitations INSTALLATION Mains connection...

Instruction Manual TABLE OF CONTENTS 1 PRINCIPLE OF OPERATION Limitations INSTALLATION Mains connection... instrumentación para fluidos CI- pulse / ma Converter Instruction Manual TABLE OF CONTENTS PRINCIPLE OF OPERATION.... Limitations.... INSTALLATION.... Mains connection........ Input connection........

More information

PRELIMINARY DATA SHEET. RI-F400 Series. easywire Single and Three Phase Multifunction Energy Meter

PRELIMINARY DATA SHEET. RI-F400 Series. easywire Single and Three Phase Multifunction Energy Meter Telephone : 44 (0) 1245 428500 PRELIMIARY DATA SHEET RIF400 Series easywire Single and Three Phase Multifunction Energy Meter DI 96 panel mounted 330mV Input from easywire CTs (or /1A and /5A current transformer

More information

Dual-Line 5-Digit Explosion-Proof Pulse Input Rate/Totalizers

Dual-Line 5-Digit Explosion-Proof Pulse Input Rate/Totalizers ProtEX-RTP PD6830 Dual-Line 5-Digit Explosion-Proof Pulse Input Rate/Totalizers TM RTP OUCH Through-Glass Button Programming flow rate/total Pulse, Open Collector, NPN, PNP, TTL, Switch Contact, Sine Wave

More information

Universal process controller econtrol

Universal process controller econtrol 8 Universal process controller Type 8 can be combined with... Continuous, point, point and On/Off control Ratio control function Sensor inputs (,, frequency, RTD) Control of proportional, process and motor

More information

( F L O W I Z F A M I L Y )

( F L O W I Z F A M I L Y ) THE MOST ACCURATE BATTERY POWERED SYSTEM ( F L O W I Z F A M I L Y ) E l e c t r o m a g n e t i c c o n v e r t e r p o w e r e d b y b a t t e r i e s, s o l a r p a n e l o r D C p o w e r w i t h 4

More information

S T T U S I N S T R U M E N T S

S T T U S I N S T R U M E N T S S T T U S I N S T R U M E N T S Welcome to the latest Status Instruments Product Guide Here at Status Instruments, we re very proud to say that we ve been making top-quality instrumentation for 30 years.

More information

Fuel Sentry System MANUAL DE OPERACION Y MANTENCION. Av. Mexico 823 Recoleta, Santiago de Chile

Fuel Sentry System MANUAL DE OPERACION Y MANTENCION. Av. Mexico 823 Recoleta, Santiago de Chile Fuel Sentry System MANUAL DE OPERACION Y MANTENCION Av. Mexico 823 Recoleta, Santiago de Chile www.dog.cl/fuelsentry dog@dog.cl Tel +56 2 2979 0377 Movil +56 9 8449 1011 FSSM Manual 012014 TABLE OF CONTENTS

More information

Electromagnetic flowmeters and switches DWM 1000/2000

Electromagnetic flowmeters and switches DWM 1000/2000 KROHNE 10/2000 D 20 DW10 02 E GR Electromagnetic flowmeters and switches DWM 1000/2000 Variable area flowmeters Vortex flowmeters Flow controllers Electromagnetic flowmeters Ultrasonic flowmeters Mass

More information

Signet Flow Transmitter

Signet Flow Transmitter Signet 80- Flow *-80.090-* English -80.090- Rev. L 0/ English WARNING! Remove power to unit before wiring input and output connections. Follow instructions carefully to avoid personal injury. Contents.

More information

VersaFlow Ultrasonic clamp-on Flowmeter Technical Datasheet. Specification. Applications. Highlights. Industries. 34-VF September 2009

VersaFlow Ultrasonic clamp-on Flowmeter Technical Datasheet. Specification. Applications. Highlights. Industries. 34-VF September 2009 VersaFlow Ultrasonic clamp-on Flowmeter Technical Datasheet 34-VF-03-14 September 2009 Specification Clamp-on technology HONEYWELL S VERSAFLOW stands for continuity and long term reliability. Flow measurement

More information