1 NEW Series EMC8S0-0 Three-Phase Induction Vac, kw (Y), kw (D) INDUCTION MOTOR SOLID-STATE REDUCED VOLTAGE STARTER (SOFTSTARTER) WITH SOFTSTOP FEATURE The Series EMC can be used as an alternative to costly and relatively big variable speed controllers in applications such as pumps, fans, compressors and conveyors. Its six-thyristor structure, working like a full-wave phase angle controller (both positive and negative cycles are controlled), reduces the induction motor starting current as well as the motor starting torque. The reduction in motor starting current improves the efficiency of the power used. It also avoids voltage fluctuations that lead to ambient light variations or flicker. The Series EMC fits existing applications without any modification of the wiring field configuration. Thus it can replace an electromechanical star-delta starter without changing the motor coupling. The EMC may be implemented like a standard three-phase electromechanical contactor for induction motors. Furthermore, its ability to be installed inside the delta wiring allows the Series EMC to drive.7 times more current than a standard online softstarter. The Series EMC features diagnostic and self-test functions to assist with machine maintenance, reduce costs, and delays of restarting equipment. MAIN CHARACTERISTICS C S tar (Y) Delta (D) 0ac ac 0ac ac C EN097-- kw 8.kW kw kw 0A.A Phase to Phase 00 to 8ac Mains Frequency 0 to Hz Input 0 to Vdc Status Output V/A AC/DC In/Out/Case Isolation kv Operating Temperature 0 C to +00 C BENEFIT FOR MOTOR STARTING TYPICAL WIRINGS DIRECT ON LINE (DOL) STARTING Speed STAR (Y) DELTA (D) In On Line Current t Mechanical part stress - Noise - Maintenance costs High inrush current - and mains protection oversized - Risk of flicker SOFTSTARTING WITH EMC Speed In On Line Current Softstarting - Noise reduction - Maintenance cost reduction No more high inrush current - and mains protection oversized - No more harmonic or flicker problems t 00 TELEDYNE RELAYS (800) EMC8S0-0 EMC8S0-0\000\Q

2 Series EMC8S0-0 SETTINGS AND DIAGNOSTIC Fig. INTERNAL DIAGRAM Fig. DESCRIPTION L L L Three-phase mains connections Phases LEDs Switches Urg. Input Bypass µler Internal Synchr. Switch Status Power Element T T T Power Elements LEDs s Status outputs / Line / Load Urg L L L L L L Option switches (Behind the label) Time Torque Options Settings connections DESCRIPTION OF THE CONNECTIONS Terminals & & & & L, L, L T, T, T Function Input/Output Activated when... Diagnostic Output Closed Bypass Output Closed Input High (PNP) or Low () es (+ / Urgent stop Input Open Three-phase mains (Obligatory) Input x0ac supply (Obligatory) Output 00ms after control NO (AC P olarization N O (AC or DC) N O (AC or DC) Y ) Y es (+ / ) N O (AC) ) Setting/Option Function Possibilities Time Increasing voltage ramp duration DESCRIPTION OF THE SETTINGS AND OPTIONS Torque Min. voltage applied to the motor at start T s=0 up to s 0 up to 00% Soft Decreasing voltage ramp duration 0, /, or x ts up to s max. Bypass Bypass presence diagnostic option (if bypass used) / type of control option PNP, or on mains presence shaft breakaway 0 up to 00ms depending on ts Proceeding Fig. DESCRIPTION OF THE DIFFERENT SETTING PARAMETERS ing Current Applied to the ( Torque ) Speed 800% In Vn (DOL) on Speed Nn ts In 0 t Shaft Turning Detection Nominal Speed: End of the Softstarting and Bypass Closing Theoretical End of the Ramp Set by the User (ts) End of the Fast Deceleration Back to the State and Diagnostic EMC8S0-0 SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE 00 TELEDYNE RELAYS EMC8S0-0\000\Q

3 Series EMC8S0-0 SETTINGS AND DIAGNOSTIC Visualization Line Visualization Line Load Load DESCRIPTION OF THE DIAGNOSTIC INFORMATION IN NORMAL OPERATION Status Output B ypass Status Output B ypass ped ped ing Running to nominal speed Decelerating DIAGNOSTICS IN CASE OF FAILURE ped ped Running ped ped Possible Cause Solution Mains voltage too low Check the phases L and L Phase(s) missing; mains frequency out of range; too much inteference Phase(s) missing Load missing; short-circuited thyristor Bypass missing (its checking is re- quired by the corresponding option) Probable Cause No mains or device not correctly wired Mains voltage and phases OK; motor detected; no control Mains voltage and phases OK; motor detected; control detected and beginning of the softstarting ramp Mains voltage and phases OK; motor detected; no control detected and end of the softstarting ramp Mains voltage and phases OK; motor detected; no control detected and beginning of the softstopping ramp Check the phases Check the phases Check the motor connections and the solid-state switches Check the bypass connections or, if not used, cancel the checking option ped ped ped ped The solid-state switches cannot close Microcontroller malfunction A problem occurred on the mains (no voltage or a phase is missing) then disappeared, but the control voltage was applied A problem occurred on the load (temporary disconnection) then disappeared, but the control voltage was applied Check if the connection between and of the control terminal block is correctly done. Check as well if the load current is sufficient. Disconnect the softstarter from the mains for a while Remove the control for a while Remove the control for a while LEGEND Off Green Red Flashing Green Flashing Red Open Closed IMPORTANT INFORMATION ABOUT THE DIAGNOSTIC. The device makes a complete diagnostic (mains, load and itself) since it has enough supply voltage (On the mains or on the control side).. The device only checks the presence of the phases and the closing of the solid-state switches during the voltage ramps (softstart and softstop) and during the full on-state period.. The control overrides the diagnostic. If a problem occurs during the control period, the device will close all the solid-state switches. If the problem goes on during the full on-state period, the corresponding information will be given to the user according to the table above. Likewise, if a problem occurs during the softstopping period, the device will stop immediately in order to reach the off-state diagnostic period.. On a hard stop (no softstop) and in the case of driving a large motor, the device may temporarily display a problem concerning the mains. This is due to an important residual voltage across the motor windings (back EMF generated by the motor rotation and the remaining magnetic field). This security allows the user to avoid connecting the motor to the mains in bad conditions. This phenomenon can be cancelled by using the softstop feature that slowly reduces the remaining magnetic field inside the motor. This also avoids overvoltage across the solid-state switches (increasing the lifetime expectancy of the integrated varistors). Therefore, softstop is recommended even with high inertia motor loads. 00 TELEDYNE RELAYS (800) EMC8S0-0 EMC8S0-0\000\Q

4 Series EMC8S0-0 CONTROL CONTROL INPUTS AND STATUS OUTPUTS Vc Fig. HIGH SIDE CONTROL (PNP) + or or Immediately Ic Ict Vt Urg. Fig. LOW SIDE CONTROL () Fig. STATUS OUTPUT UTILIZATION or Vt Immediately Ict or Ict Vt Urg. Vsa Bypass Contactor Line Contactor Indicators PLC Inputs... Iby Ipb Urg. Input Function ELECTRICAL CHARACTERISTICS OF THE STARTING AND STOPPING INPUTS (Given at 0 ling the device Urg. Immediately stop the device Opening the connection to zero volt & Type (Depending on the option switches) High side control (PNP) Low side control () Concerned Terminals & & Range (according to EN097--) Vc 0-Vdc M in. Vcmin. 8.V Drop Input Reverse Release Current Current to Switch Vt Vcmax=8Vdc Vcmax=8Vdc Vc<Vdc 9mAdc.Vdc.Vdc Vtmax=8Vdc Vtmax=8Vdc Vt>.Vdc Vtmax=Vdc Vtmax=Vdc Vt>.Vdc Ic See Fig. 7 Ict 0-00µ Adc 0mAdc Depends on Vt STATUS OUTPUT CHARACTERISTICS (Given at 0 O utput Bypass Concerned Terminals & & Function Indicates the end of the starting Environment problem detection or period and can be used to control a faulty device indication bypass electromechanical contactor Nom. Operating Operating Range Non-Repetitive Peak Protection Against Overvoltage Min. Load Current Permanent Current Overload Current Protection Against Short Circuits On-State Resistance Off-State Resistance Off-State Capacitance Turn-On Time Turn-Off Time Vsan Vsa Vsapmax Ibymin Ipbmin Iby/Ipb Ibyp/Ipbp Ron Roff Coff Toff Ton Vac/dc 0-8Vac/dc Yes; V size 7 varistors integrated See Fig. & 0 A ac/dc See Fig. 8.A ac/dc 0% of the cycle 00mΩ See Fig. 9 00MΩ 0pF See Fig. 0 0.ms ms EMC8S0-0 SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE 00 TELEDYNE RELAYS EMC8S0-0\000\Q

5 Series EMC8S0-0 CONTROL CHARACTERISTIC CURVES OF THE CONTROLLING INPUTS AND STATUS OUTPUTS Fig. 7 CONTROL INPUT CURRENT/VOLTAGE CHARACTERISTIC IN PNP MODE (HIGH SIDE CONTROL) Fig. 8 MAX. OUTPUT STATUS CURRENT VERSUS AMBIENT TEMPERATURE Current Ic in ma Vc Releasing Vc min Range According to EN097-- Vc max Load Current Iby / Ipb (A) Vc in Volts 0. Ambient Temperature ( C) Fig. 9 OFF-STATE STATUS OUTPUT PARASITIC CAPACITANCE VERSUS OUTPUT VOLTAGE Fig. 0 ON-STATE STATUS OUTPUT RESISTANCE VERSUS AMBIENT TEMPERATURE Output Capacitance Coff (pf) Output Resistance Roff (mω) Auxiliary Vsa (V) Ambient Temperature ( C) Fig. STATUS OUTPUT OVERVOLTAGE PROTECTION CHARACTERISTIC Fig. MAX. OVERLOAD PULSES REGARDING DURATION FOR OVERVOLTAGE PROTECTION OF STATUS OUTPUTS 00 v 0 A i max x x tr imax A 0 i tr 00 TELEDYNE RELAYS (800) EMC8S0-0 EMC8S0-0\000\Q

6 Series EMC8S0-0 POWER INTERNAL SUPPLY ELECTRICAL CHARACTERISTICS (Given at 0 Concerned Terminals L & L Range Consumption Ve Is 00-8ac ma typical Frequency Range f 0-Hz Turn-On Time tm 00ms See Fig. POWER SIDE CHARACTERISTICS (Given at 0 Concerned Terminals L, T, L, T, L, T Max Power of Star Wiring (Y) Pn kw Max Power of Star Wiring (Y) Pn 8.kW Max Power of Delta Wiring (D) Pn kw Max Power of Delta Wiring (D) Pn kw Nom. Operating Operating Range Non-repetitive Peak Integrated Overvoltage Protection Ven Ve Vep ac & 0ac 00-8ac 0 Yes size varistors Device wired inside the delta Device wired inside the delta See Fig. & 7 ACa Nom. Current according to Ie Hard conditions.a EN097-- (Induction ) (ACa) See Fig. ACa Permanent Current Ie Normal conditions 0A (Induction ) (ACa) See Fig. AC Permanent Current 0A Ith (AC) (Resistive Loads) (A if the wire cross-section is doubled for each power terminal) e.g. softstarting lamps Non-repetitive Peak Overload Current ( cycle of 0ms) ITSM 000A See Fig. Fusing Limit Current for Choosing the Protecting Fuses I t 0000A Min. Load Current Iemin 00mA Leakage Current Ik 0Hz Power Factor Pf 0- Operating Mains Frequency Range F 0-Hz Off-state dv/dt d v/dt 0/ µs Integrated Transient Protection Current Rising Time Direct Drop Resistive Part of the Direct Drop Threshold Part of the Direct Drop Junction Temperature Junction/Plate Thermal Resistance Per Power Element Plate/Heatsink Thermal Resistance Vertically Mounted Heatsink Thermal Resistance Heatsink Thermal Time Constant d i/dt / Vd rt Vto Tjmax Rthjc Rthcs Rthra Tthra Yes RC network 0A C C C 0. K/ W 0.0 K/ W Total = power elements 0. K/ Tra=0 C Tra=0 C EMC8S0-0 SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE 00 TELEDYNE RELAYS EMC8S0-0\000\Q

7 Series EMC8S0-0 POWER CHARACTERISTIC CURVES OF THE POWER ELEMENTS Fig. ELECTRICAL LABEL DESCRIPTION Fig. OVERLOAD CURRENT CHARACTERISTIC REGARDING OVERLOAD DURATION Three Phase Mains Ie Ve Is Ie Is Ie ITSM (A) (Peak ) / Line / Load Urg L L L L L L Vd Repetitive Non-repetitive Time(s) Load Fig. NOMINAL CURRENTS VERSUS AMBIENT TEMPERATURE Permanent Current Ie (ARMS) ATTENTION: The maximum wire cross-section is 0mm without furrule. When current exceeds 0A, it may be necessary to double the wire number per terminal Resistive load control (AC) Limit for heat sink temperature below 00 C (Resistive loads; AC current) Limit for heat sink temperature below 80 C according to EN097 (Resistive loads; AC current) Limit for motor control in normal use (ACa current) Limit for motor control with hard conditions according to EN097-- (ACa current) Dissipated Power (W) 0 0 control (ACa) Fig. OVERVOLTAGE PROTECTION CHARACTERISTIC (VARISTORS) Fig. 7 MAX. OVERLOAD PULSES REGARDING DURATION FOR OVERVOLTAGE PROTECTION OF POWER ELEMENTS v A i max 0 x x 0 tr i max A 0 i t r 00 TELEDYNE RELAYS (800) EMC8S0-0 7 EMC8S0-0\000\Q

8 Series EMC8S0-0 GENERAL Power Output/Input Isolation Status Outputs / Input Isolation Plate/Input Isolation Status Output/Plate Isolation Isolation Resistance Isolation Capacitance Vimp Vied Vimp Vimp Rio Cio INPUT/OUTPUT ISOLATION CHARACTERISTICS (Given at 0 Kv.Kv Kv Kv GΩ <8pF Storage Ambient Temperature Ambient Operating Temperature Max Heat Sink Temperature et Heat Resistance (Continuous) et Heat Resistance (Cyclical) Tstg Tamb Tc CLIMATIC OPERATING ENVIRONMENT (Given at 0 0 to 00 C 0 to 90 C 00 C According to I.E.C. 8 parts According to I.E.C. 8 parts W & W & 0 Connections Screwdriver Wire Cross Section Min. & Tightening Torque CONNECTIONS AND REQUIRED TOOLS ON THE CONTROL SIDE (Given at 0 Screwed 0.8 x mm.mm Connections Screwdriver Wire Cross Section Min. & Tightening Torque Possible Number of Connected Wires for the Cross Section CONNECTIONS AND REQUIRED TOOLS ON THE POWER SIDE (Given at 0 Screwed Posidriv or 0.8 x.mm.-mm ( 0mm without ferrule).8 to N. m CHARACTERTISTICS AND REQUIRED TOOLS FOR THE SETTINGS (Given at 0 S etting " Time" and " Torque" Option Switches Screwdriver Number of Postions 0 for each switch C hanging Position Required Torque >.N.cm +/ 0% >N.cm +/ 0% A ngle Between Each Position 0 MISCELLANEOUS CHARACTERISTICS (Given at 0 Housing UL9V0 Mounting Noise Level eight Omega DIN rail (DIN00) or screwed Low audible vibration during the softstarting and softstopping periods 9.7 oz. (00g W ) Rotary switches: No rotation stop EMC8S0-0 8 SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE 00 TELEDYNE RELAYS EMC8S0-0\000\Q

9 Series EMC8S0-0 GENERAL Fig. 8 DIMENSIONS.0 () Ve V 0/HZ AC-a Ie 0 A V imp 00 IEC97-- EN FOR RATINGS SEE INSTRUC. SHEET / Line / Load L L L Urg Æ L L L.99 (7). (90). ().8 (8) AC. (0) Contact Type Closing Temperature Opening Temperature Nom. Nom. Current Contact Resistance Isolation Between Opened Contacts Isolation Between Contacts and Housing Isolation Resistance Connections CHARACTERISTICS OF THE THERMAL PROTECTION (Given at 0 Normally closed 90 C +/ C 80 C ac/dc A 0mΩ 0GΩ kv 0GΩ.8mm flat tabs or welded wires CHARACTERISTICS OF THE FAN Consumption Frequency Speed Noise Level Connections (Given at 0 Shaded pole induction motor ac 9W 8mA 0-0Hz 00 RPM dba.8mm flat tabs 00 TELEDYNE RELAYS (800) EMC8S0-0 9 EMC8S0-0\000\Q

10 Series EMC8S0-0 STANDARDS Electrostatic discharges Radiated Electromagnetic Fields Fast Transient Bursts Electric Shocks Drop IMMUNITY LEVEL WITHIN ELECTROMAGNETIC COMPATIBILITY (E.M.C.) EN EN EN EN EN (Given at 0 8kV in the air kv contact /m kv direct coupling on the power side kv clamped coupling on the input side kv direct coupling differential mode (Input and output sides) kv direct coupling common mode (Input and output sides) EMISSION LEVEL WITHIN ELECTROMAGNETIC COMPATIBILITY (E.M.C.) Conducted Disturbances EN0 Radiated Disturbances EN0 Concerning Filtering (Given at 0 In compliance with the standards for industrial field In compliance with the standards for domestic field with an external bypass contactor < 0dbµ V for the frequency range 0 0MHz < 7dbµ V for the frequency range 0 000MHz The conducted or radiated disturbances generated by solid- state relays depend on the wiring and load configuration. The test method recommended by the European standards concerning electromagnetic compatibility leads to results far from reality. We recommend use of filters based on your application. The European standard EN097-- requires the measurement to be done at full on state (end of the softstarting period). Therefore, our products are below the industrial field required levels on inductive load like the induction motor and no additional filter is needed. The starting period that may last several minutes generates enough interference to disturb sensitive devices located near the softstarter. No state changing or destruction No state changing or destruction No state changing or destruction No state changing or destruction LOW-VOLTAGE DIRECTIVE (Given at 0 Standard EN097-- Protection Level Protection for Direct Touch IP L0 According to V.D.E. 0 part 00; Back hand and finger safety CE Marking EN c UL US UL08 VDE 080 EN090 APPROVALS (Given at 0 Yes Pending Pending Office environment EMC8S0-0 0 SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE 00 TELEDYNE RELAYS EMC8S0-0\000\Q

11 Series EMC8S0-0 STANDARDS DANGER! IMPORTANT The installation of this product must be done by qualified people, informed about electric hazards (electrocution risks linked to the voltage levels in the circuit). Any intervention on the installation must be operated with the circuit disconnected from the electric grid by an electromechanical mean insuring a sufficient galvanic isolation. The EMC is composed of silicon-based solid-state switches. They never ensure a safe function when they are not controlled (important leakage current and untimely closing). Therefore, we advise you to use an electromechanical device in series with the softstarter, which can ensure a safe operation in the disconnected circuit. The emergency stop must not be done by the softstarter. It must be done by an electromechanical mean with sufficient current breaking possibility. In order to operate the circuit safely, the control part of the softstarter will have to be disconnected from the control or auxiliary supplies as well. ATTENTION. The EMC does not correctly operate on three-phase mains with the motor neutral connected to the neutral of the mains. If you have such a requirement, please contact us.. The overload relay must be adapted to the motor.. Please take care not to make short circuits while installing the bypass contactor or the backward wires for delta wiring.. In case of devices planned to be used connected to a bypass contactor, the control voltage will have to be held sufficiently to allow the bypass to close. Verify the bypass checking option byp.. In case of fast softstarting and softstopping controls without waiting for the end of the ramps, the motor may heat up. Please contact your motor supplier to choose an adapted model. Devices On Line Fuses (Hard conditions according to EN097--) On Line Fuses (Normal conditions) Overload Relay (Hard conditions according to EN097--) Overload Relay (Normal conditions) Breaking Capability of the Bypass Contactor ypass Contactor Coil ENVIRONMENT OF THE SOFTSTARTER Description FERRAZ x am 0/0 To be determined by the user Moeller Z00- class 0A To be determined by the user KM 0A AC B A /A VAmax. / W max. Thermal Protection Wiring / Settings T C Not available Comply with the characteristics given in general information 00 TELEDYNE RELAYS (800) EMC8S0-0 EMC8S0-0\000\Q

12 Series EMC8S0-0 INSTALLATION WIRING POSSIBILITIES Fig. 9 HIGH SIDE CONTROL (PNP) L L L L L L Auxiliary AC/DC 0 >Vdc + T C T T T L<9.9 in. (0cm) max. / Immediately / Line / Load L L L L L L A + Urg. Ctrl L L L KM A A KM User Information 0. T T T A U V W W M~ U V Delta Coupling Fig. 0 LOW SIDE CONTROL () L L L L L L Auxiliary AC/DC T C T T T L<9.9 in. (0cm) max. Immediately / Line / Load L L L L L L A + Urg. Ctrl L L L KM A A KM User Information 0. T T T A U V W W M~ U V Delta Coupling EMC8S0-0 SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE 00 TELEDYNE RELAYS EMC8S0-0\000\Q

13 Series EMC8S0-0 INSTALLATION WIRING POSSIBILITIES Fig. UPON THE MAINS CONTROL L L L L L L Auxiliary AC/DC T C T T T L<9.9 in. (0cm) / Immediately / Line / Load L L L L L L A Urg. L L L KM A A KM User Information 0. T T T A U V W W M~ U V Delta Coupling OTHER LOAD POSSIBILITIES SOFTSTARTING INCANDESCENT OR INFRARED LAMPS (AC CURRENT) SOFTSTARTING THREE-PHASE LOADED TRANSFORMERS (PLEASE CONTACT US) L L L L L L L<9.9 in. (0cm) L<9.9 in. (0cm) / Line / Load Urg. L L L L L L L L L A KM / Line / Load + Urg. Ctrl L L L L T L L T T A KM A T T T A Delta Coupling Delta Coupling Load 00 TELEDYNE RELAYS (800) EMC8S0-0 EMC8S0-0\000\Q

14 Series EMC8S0-0 INSTALLATION MOUNTING Fig. MOUNTING PRECAUTIONS The heat sink fins must be mounted vertically to ensure a good thermal convection. A minimum space must be left free around the assembly. MOUNTING WITH SCREWS Ø (.) 0.98 ().97 (00) Ø (.) MOUNTING OMEGA DIN RAIL MOUNTING (EN00) FIXING REMOVING EMC8S0-0 SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE 00 TELEDYNE RELAYS EMC8S0-0\000\Q

15 Series EMC8S0-0 INSTALLATION ADVICE FOR THE SETTINGS ATTENTION Obtaining a particular starting time value is only a consequence of the motor torque reduction and cannot be guaranteed or easily repeatable. The rotary switch < Time (s) > setting values only give the duration of the voltage ramp applied to the motor but not necessarily its starting time. The main EMC function is to obtain a motor torque reduction to take care of the motor load and the electric grid. The motor starting time is only a consequence and completely depends on the motor itself, its load and the settings done by the user. The EMC cannot break a motor driving a load that has much inertia. The user can only obtain a stop time equal or longer than a simple disconnection from the electric grid. Using the softstop feature can only be justified when the motor load tends to break the motor (pumps,...) or when the products treated by the machine need to be stopped slowly (conveyors,...). In the case of a load with high inertia, the softstop feature can help to reduce slowly the magnetic field inside the motor to avoid long time overvoltage in the circuit. SETTING EXAMPLES Direct On Line ing (DOL) Long ing Time for Lamps, Transformers... (On a motor, it may hum) Advised Settings for Testing the ing Loads with Increasing Torque Like N and Increasing Power Like N Loads with Decreasing Torque Like /N and Constant Power Load Examples Advised Time Setting Load Examples Advised Time Setting Fans, centrifugal pumps,... Depending on the user starting time requirement Winding material around a shaft (cable, paper, metal, textile, plastic...), chip disposal... Maximum (s) Torque Curve Advised Torque Setting Torque Curve Advised Torque Setting C Adjusted to avoid motor hum C Depending on the user starting current requirement Softstop Softstop N / of the starting time (Magnetic field reduction) N / of the starting time (Magnetic field reduction) Loads with Constant Torque and Increasing Power Like N Loads Increasing Like N and Constant Power Load Examples Advised Time Setting Load Examples Advised Time Setting Conveyors, cranes, constant volume pumps Maximum (s) Machine tools, rolling mills,... Depending on the user starting time requirement Torque Curve Advised Torque Setting Torque Curve Advised Torque Setting C Depending on the user starting current requirement C Adjusted to avoid motor hum Softstop Softstop N Depending on the user stopping smoothness requirement N Depending on the user stopping smoothness requirement 00 TELEDYNE RELAYS (800) EMC8S0-0 EMC8S0-0\000\Q

Control Input. Status Ouputs. 0 to 24VDC 1A AC/DC. Fig. 1 TYPICAL APPLICATIONS Fig. 2 WIRING DIAGRAM

Control Input. Status Ouputs. 0 to 24VDC 1A AC/DC. Fig. 1 TYPICAL APPLICATIONS Fig. 2 WIRING DIAGRAM SVTA4690 DIGITAL THREE PHASE ANGLE CONTROLLER Farnell order relais code code 399-6335 SVTA4690! Allows to set the voltage applied to different sort of loads :! Resistive (Bulbs, UV and IR lamps, ovens,

More information

Status Ouputs. Control Input. 0 to 24VDC 1A AC/DC. 4-20mADC. Fig. 1 TYPICAL APPLICATIONS Fig. 2 WIRING DIAGRAM

Status Ouputs. Control Input. 0 to 24VDC 1A AC/DC. 4-20mADC. Fig. 1 TYPICAL APPLICATIONS Fig. 2 WIRING DIAGRAM Page 1/6 GB DIGITAL THREE PHASE ANGLE CONTROLLER Allows to set the voltage applied to different sort of loads with 3 wires, 4 wires or inside the delta wiring: Resistive (Bulbs, UV and IR lamps, ovens,

More information

Status Ouputs. Control Input. 0 to 24VDC 1A AC/DC 0-10VDC. Fig. 1 TYPICAL APPLICATIONS Fig. 2 WIRING DIAGRAM

Status Ouputs. Control Input. 0 to 24VDC 1A AC/DC 0-10VDC. Fig. 1 TYPICAL APPLICATIONS Fig. 2 WIRING DIAGRAM Page 1/6 GB DIGITAL THREE PHASE ANGLE CTROLLER Allows to set the voltage applied to different sort of loads with 3 wires, 4 wires or inside the delta wiring: Resistive (Bulbs, UV and IR lamps, ovens, ),

More information

Status Ouputs. Control Input. 0 to 24VDC 1A AC/DC 0-10VDC. Fig. 1 TYPICAL APPLICATIONS Fig. 2 WIRING DIAGRAM

Status Ouputs. Control Input. 0 to 24VDC 1A AC/DC 0-10VDC. Fig. 1 TYPICAL APPLICATIONS Fig. 2 WIRING DIAGRAM Page 1/6 GB DIGITAL THREE PHASE ANGLE CTROLLER Allows to set the voltage applied to different sort of loads with 3 wires, 4 wires or inside the delta wiring: Resistive (Bulbs, UV and IR lamps, ovens, ),

More information

celduc r e l a i s Proud to serve you celduc MOSFET BASED DC SOLID STATE RELAY SCM VDC 200VDC 100ADC Page 1/5 GB

celduc r e l a i s Proud to serve you celduc MOSFET BASED DC SOLID STATE RELAY SCM VDC 200VDC 100ADC Page 1/5 GB Page 1/5 GB MOSFET BASED DC SOLID STATE RELAY SCM2! Latest MOSFET technology generation.! Ultra low on-state resistance.! New innovative isolated driver ensuring fast power transistor turn on and off therefore

More information

MOSFET BASED DC SOLID-STATE RELAY. In & case / Out Insulation. Fig. 2. Please consult us to select the right protective components C1, D1 & D2.

MOSFET BASED DC SOLID-STATE RELAY. In & case / Out Insulation. Fig. 2. Please consult us to select the right protective components C1, D1 & D2. Page 1/5 UK MOSFET BASED DC SOLID-STATE RELAY SCM0150100 Latest MOSFET technology generation. Ultra low on-state resistance. New innovative isolated driver ensuring fast power transistor turn on and off

More information

IGBT BASED DC SOLID-STATE RELAY. In & case / Out Insulation. Fig. 2. Please consult us to select the right protective components C1, D1 & D2.

IGBT BASED DC SOLID-STATE RELAY. In & case / Out Insulation. Fig. 2. Please consult us to select the right protective components C1, D1 & D2. S/CON/SCI512/D/19/12/14 Page 1/5 UK IGBT BASED DC SOLID-STATE RELAY SCI512 Latest high voltage IGBT technology generation. New innovative isolated driver ensuring fast power transistor turn on and off

More information

IGBT BASED DC SOLID-STATE RELAY. In & case / Out Insulation. Fig. 2. Please consult us to select the right protective components C1, D1 & D2.

IGBT BASED DC SOLID-STATE RELAY. In & case / Out Insulation. Fig. 2. Please consult us to select the right protective components C1, D1 & D2. S/CON/SCI2517/C/19/12/14 Page 1/5 UK IGBT BASED DC SOLID-STATE RELAY SCI2517 Latest high voltage IGBT technology generation. New innovative isolated driver ensuring fast power transistor turn on and off

More information

PRELIMINARY DATA MOSFET BASED DC SOLID-STATE RELAY. In & case / Out Insulation VDC 2.5kV Screw terminals 45 x 58.5 x 30 80g. Fig.

PRELIMINARY DATA MOSFET BASED DC SOLID-STATE RELAY. In & case / Out Insulation VDC 2.5kV Screw terminals 45 x 58.5 x 30 80g. Fig. MOSFET BASED DC SOLID-STATE RELAY Page 1/ UK SOM41 Latest MOSFET technology generation. Ultra low on-state resistance. Low output leakage current. Low control current consumption. Built-in overvoltage

More information

celduc r e l a i s Proud to serve you MOSFET BASED DC SOLID STATE RELAY SCM VDC 600VDC 40ADC Page 1/5 GB

celduc r e l a i s Proud to serve you MOSFET BASED DC SOLID STATE RELAY SCM VDC 600VDC 40ADC Page 1/5 GB Page 1/5 GB MOSFET BASED DC SOLID STATE RELAY SCM6 Latest MOSFET technology generation. Ultra low on-state resistance. New innovative isolated driver ensuring fast power transistor turn on and off therefore

More information

MOSFET BASED DC SOLID-STATE RELAY. In & case / Out Insulation VDC 2.5kV Screw terminals 45 x 58.5 x 30 80g. Fig. 2

MOSFET BASED DC SOLID-STATE RELAY. In & case / Out Insulation VDC 2.5kV Screw terminals 45 x 58.5 x 30 80g. Fig. 2 S/CON/SOM42/B/18/12/14 Page 1/5 UK MOSFET BASED DC SOLID-STATE RELAY SOM42 Latest MOSFET technology generation. Ultra low on-state resistance. Low output leakage current. Low control current consumption.

More information

MOSFET BASED DC SOLID-STATE RELAY. In & case / Out Insulation VDC 2.5kV Screw terminals 45 x 58.5 x 30 80g. Fig. 2

MOSFET BASED DC SOLID-STATE RELAY. In & case / Out Insulation VDC 2.5kV Screw terminals 45 x 58.5 x 30 80g. Fig. 2 S/CON/SOM26/B/18/12/14 Page 1/6 UK MOSFET BASED DC SOLID-STATE RELAY SOM26 Latest MOSFET technology generation. Ultra low on-state resistance. Low output leakage current. Low control current consumption.

More information

celduc r e l a i s Proud to serve you XKLD31006 DOCUMENT PRELIMINAIRE RELAIS STATIQUE A MOSFET POUR COURANT CONTINU 10-30VDC 40V (60V crête) 10ADC

celduc r e l a i s Proud to serve you XKLD31006 DOCUMENT PRELIMINAIRE RELAIS STATIQUE A MOSFET POUR COURANT CONTINU 10-30VDC 40V (60V crête) 10ADC DOCUMENT PRELIMINAIRE RELAIS STATIQUE A MOSFET POUR COURANT CONTINU Montage rail DIN Technologie à base de MOSFET dernière génération. Très faible résistance à l état passant. Protection contre les surtensions

More information

celduc SIM Phase angle controller Output : VAC 40A(*) Input : Analog 0-10V r e l a i s celpac

celduc SIM Phase angle controller Output : VAC 40A(*) Input : Analog 0-10V r e l a i s celpac Power Solid State Relay With Analog Control, pitch 22.5mm compact size and DIN rail mounting. Ready to use Single-Phase Relay: Phase angle ler Transfer characterisic :Angle open loop Operating voltage

More information

celduc SILD r e l a i s celpac PATENTED! AC Semiconductor Contactor pitch 22,5mm with Diagnostic compact size and DIN rail mounting.

celduc SILD r e l a i s celpac PATENTED! AC Semiconductor Contactor pitch 22,5mm with Diagnostic compact size and DIN rail mounting. AC Semiconductor Contactor pitch,5mm with Diagnostic compact size and DIN rail mounting. Ready to use SinglePhase Relay: " Install it & Forget it!" Zero cross model : 55VAC 5A back to back thyristors on

More information

MOSFET BASED DC SOLID-STATE RELAY (With built-in transient voltage suppressor) In & case / Out Insulation

MOSFET BASED DC SOLID-STATE RELAY (With built-in transient voltage suppressor) In & case / Out Insulation S/CON/SOM675/C/18/12/14 Page 1/6 UK MOSFET BASED DC SOLID-STATE RELAY (With built-in transient voltage suppressor) SOM675 Latest MOSFET technology generation. Ultra low on-state resistance. Low output

More information

celduc SILD Output : VAC 32A(*) Input : 3-32VDC - I<10mA Diagnostic : 30VDC - 100mA r e l a i s celpac P roud to serve you

celduc SILD Output : VAC 32A(*) Input : 3-32VDC - I<10mA Diagnostic : 30VDC - 100mA r e l a i s celpac P roud to serve you AC Semiconductor Contactor pitch 22,5mm with Diagnostic compact size and DIN rail mounting. Ready to use Single-Phase Relay: " Install it & Forget it!" Zero cross model : 7-28AC 5A back to back thyristors

More information

celduc SIL Phase angle controller Output : VAC 32A(*) Input : Analog 0-10V celpac r e l a i s Proud to serve you

celduc SIL Phase angle controller Output : VAC 32A(*) Input : Analog 0-10V celpac r e l a i s Proud to serve you Power Solid State Relay With Analog Control, pitch 22.5mm compact size and DIN rail mounting. Ready to use SinglePhase Relay: Phase angle controller Transfer characterisic :Angle open loop Operating voltage

More information

CI-tronic Soft start motor controller

CI-tronic Soft start motor controller Data sheet CI-tronic Soft start motor controller MCI 3, MCI 15, MCI, MCI 30 I-O, MCI 40-3D I-O and MCI 50-3 I-O The MCI soft starters are designed for soft starting and stopping of 3 phase AC motors, thus

More information

Type CP-S, CP-C & CP-A Switch mode

Type CP-S, CP-C & CP-A Switch mode Switch mode power CP-S, CP-C & CP-A Switch mode Characteristics CP-S and CP-C range Output current 5 A, 10 A and 20 A Integrated power reserve of up to 50 % 5 A and 10 A devices with pluggable connecting

More information

celduc SIM Phase angle controller Output : VAC 40A(*) Input : Analog 0-10V celpac r e l a i s Proud to serve you

celduc SIM Phase angle controller Output : VAC 40A(*) Input : Analog 0-10V celpac r e l a i s Proud to serve you Power Solid State Relay With Analog Control, pitch.5mm compact size and DIN rail mounting. Ready to use SinglePhase Relay: Phase angle controller Transfer characterisic :Angle open loop Operating voltage

More information

NEW Series STH Output to 75A, 600 Vac High Industrial Performance (HIPpak) Solid-State Relays

NEW Series STH Output to 75A, 600 Vac High Industrial Performance (HIPpak) Solid-State Relays FEATURES/BENEFITS Zero-cross models for resistive loads Low zero-cross turn-on voltage Input protection and control LED standard IP20 touch-proof flaps optional Connectors for power wiring and heat sinks

More information

Solid-state Timer H3DS

Solid-state Timer H3DS Solid-state Timer H3DS DIN Track Mounted, Standard 17.5-mm Width Timer Range A wide AC/DC power supply range (24 to 230 VAC/ 24 to 48 VDC) reduces the number of timer models kept in stock. (24 to 230 VAC/VDC

More information

References 1 for asynchronous motors 1

References 1 for asynchronous motors 1 References 1 DF56902 DF5690 DF56901 ATS 01N10FT ATS 01N212QN ATS 01N20LY for 0.7 to kw motors power Nominal current Reference (2) Weight Single phase -phase 20 V 210 V 20 V 20 V 400 V 460 V kw HP kw HP

More information

ATS01N125FT soft starter for asynchronous motor - ATS01-25 A V KW

ATS01N125FT soft starter for asynchronous motor - ATS01-25 A V KW Characteristics soft starter for asynchronous motor - ATS01-25 A - 110..480V - 2.2..11 KW Main Range of product Altistart 01 Product or component type Product destination Product specific application Device

More information

ATS01N112FT soft starter for asynchronous motor - ATS01-12 A V KW

ATS01N112FT soft starter for asynchronous motor - ATS01-12 A V KW Characteristics soft starter for asynchronous motor - ATS01-12 A - 110..480V - 1.5..5.5 KW Main Range of product Altistart 01 Product or component type Product destination Product specific application

More information

Power supply CP-D 24/4.2 Primary switch mode power supply

Power supply CP-D 24/4.2 Primary switch mode power supply Data sheet Power supply CP-D 24/4.2 Primary switch mode power supply The CP-D range of modular power supply units in MDRC design (modular DIN rail components) is ideally suited for installation in distribution

More information

Power supply CP-E 24/0.75

Power supply CP-E 24/0.75 2CDC 271 016 F0t06 a OUTPUT L+, L : terminals output b INPUT L, N, PE: terminals input c LOW: red LED output voltage too low d OK: green LED output voltage OK e OUTPUT Adjust: rotary potentiometer output

More information

ATS01N206QN soft starter for asynchronous motor - ATS01-6 A V KW

ATS01N206QN soft starter for asynchronous motor - ATS01-6 A V KW Characteristics soft starter for asynchronous motor - ATS01-6 A - 380..415V - 1.5..3 KW Main Range of product Altistart 01 Product or component type Product destination Product specific application Device

More information

Model Number Structure. Ordering Information. Solid-state Power OFF-delay Timer H3DE-H. Model Number Legend. List of Models

Model Number Structure. Ordering Information. Solid-state Power OFF-delay Timer H3DE-H. Model Number Legend. List of Models Solid-state Power OFF-delay Timer H3DE-H Timers Two delay-time models available. 0.1 to 12 seconds (S Series) 1 to 120 seconds (L Series) Covers wide range of supply voltage. Model Number Structure Model

More information

DATASHEET - ETR4-70-A. Delivery program. Timing relay, 2W, 0.05s-100h, multi-function, VAC/DC, potentiometer connection

DATASHEET - ETR4-70-A. Delivery program. Timing relay, 2W, 0.05s-100h, multi-function, VAC/DC, potentiometer connection DATASHEET - ETR4-70-A Delivery program Timing relay, 2W, 0.05s-100h, multi-function, 24-240VAC/DC, potentiometer connection Part no. ETR4-70-A Catalog No. 031888 Eaton Catalog No. XTTR6A100H70B EL-Nummer

More information

Type: DILM80(110V50HZ,120V60HZ) Article No.: Sales text Contactor,37kW/400V,AC operated. Ordering information

Type: DILM80(110V50HZ,120V60HZ) Article No.: Sales text Contactor,37kW/400V,AC operated. Ordering information Type: DILM80(110V50HZ,120V60HZ) Article No.: 239399 Sales text Contactor,37kW/400V,AC operated Ordering information Connection technique Description Description Rated operational current AC 3 380 V 400

More information

Power supply CP-E 24/2.5

Power supply CP-E 24/2.5 2CDC 271 015 F0t06 a OUTPUT L+, L : terminals output b DC OK: terminal signalling output c INPUT L, N, PE: terminals input d OUTPUT OK: green LED output voltage OK e OUTPUT Adjust: potentiometer adjustment

More information

DATASHEET - ETR4-51-A. Delivery program. Technical data General. Timing relay, star-delta, 50 ms, 1W, 3-60s, VAC/DC

DATASHEET - ETR4-51-A. Delivery program. Technical data General. Timing relay, star-delta, 50 ms, 1W, 3-60s, VAC/DC DATASHEET - ETR4-51-A Timing relay, star-delta, 50 ms, 1W, 3-60s, 24-240VAC/DC Part no. ETR4-51-A Catalog No. 031884 Eaton Catalog No. XTTR6A60S51B EL-Nummer 0004133308 (Norway) Delivery program Product

More information

ATS01N222LU soft starter for asynchronous motor - ATS01-22 A V KW

ATS01N222LU soft starter for asynchronous motor - ATS01-22 A V KW Characteristics soft starter for asynchronous motor - ATS01-22 A - 200..240 V - 4..5.5 KW Main Range of product Altistart 01 Product or component type Product destination Product specific application Device

More information

Type: DILM95(230V50HZ,240V60HZ) Article No.: Sales text Contactor,45kW/400V,AC operated. Ordering information

Type: DILM95(230V50HZ,240V60HZ) Article No.: Sales text Contactor,45kW/400V,AC operated. Ordering information Type: DILM95(230V50HZ,240V60HZ) Article No.: 239480 Sales text Contactor,45kW/400V,AC operated Ordering information Connection technique Description Description Rated operational current AC 3 380 V 400

More information

Electronic timer CT-SDS.22 Star-delta change-over with 2 n/o contacts Data sheet

Electronic timer CT-SDS.22 Star-delta change-over with 2 n/o contacts Data sheet CDC 0 F0t07 Features Rated control supply voltage -8 V DC, -0 V AC Single-function timer with star-delta change-over One device includes 7 time ranges (0.0 s - 0 min) n/o contacts LEDs for status indication

More information

Current monitoring relays CM-SRS.2 For single-phase AC/DC currents

Current monitoring relays CM-SRS.2 For single-phase AC/DC currents Data sheet Current monitoring relays CM-SRS.2 For single-phase AC/DC currents The CM-SRS.2 is an electronic current monitoring relay that protects single-phase mains (DC or AC) from over- and undercurrent

More information

Electronic timer CT-SDD.22

Electronic timer CT-SDD.22 CDC 099 F0t0 a Rotary switch for the preselection of the time range b Potentiometer with direct reading scale for the fine adjustment of the time delay c U: green LED V control supply voltage applied W

More information

Power supply CP-T 48/5.0 Primary switch mode power supply

Power supply CP-T 48/5.0 Primary switch mode power supply Data sheet Power supply CP-T 48/5.0 Primary switch mode power supply The CP-T range of three-phase power supply units is the youngest member of ABB s power supply family. In terms of design and functionality,

More information

Measuring and monitoring relays CM-SRS.1 Current monitoring relays, single-phase AC/DC

Measuring and monitoring relays CM-SRS.1 Current monitoring relays, single-phase AC/DC 2CDC 251 244 F0t05 Characteristics Monitoring of DC and AC currents: RMS measuring principle One device includes 3 measuring ranges Over- or undercurrent monitoring configurable Hysteresis adjustable from

More information

DSA150 Series. xxx Series. 150 Watts. AC-DC Power Supplies. Models & Ratings. Mechanical Details 3.92 (99.8) 2.18 (55.5) 4.92 (125.

DSA150 Series. xxx Series. 150 Watts.   AC-DC Power Supplies. Models & Ratings. Mechanical Details 3.92 (99.8) 2.18 (55.5) 4.92 (125. 15 Watts xxx Series Ultra Slim Design 15% Peak Load for 3 seconds Ambient Operation from -1 C to +7 C High Efficiency Selectable Overload Characteristic Selectable Remote Inhibit or Enable 3 Year Warranty

More information

Power supply CP-E 48/5.0 Primary switch mode power supply Data sheet

Power supply CP-E 48/5.0 Primary switch mode power supply Data sheet 2CDC 271 028 F0008 OUTPUT L+, L+, L-, L-: terminals - output Features Rated output voltage 48 V DC Output voltage adjustable via front-face rotary potentiometer OUTPUT Adjust Rated output current 5 A Rated

More information

Solid State Relays 1- and 2 Pole SOLITRON With Integrated Heatsink

Solid State Relays 1- and 2 Pole SOLITRON With Integrated Heatsink Solid State Relays 1- and 2 Pole SOLITRON With Integrated Heatsink AC Solid State Contactor, 1- and 2 poles Zero switching for heating and motor applications Instant-on switching Rated operational current

More information

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages Data sheet Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages The CM-ESS.2 is an electronic voltage monitoring relay that provides reliable monitoring of voltages as well as detection of

More information

Power supply CP-E 24/20.0

Power supply CP-E 24/20.0 2CDC 271 027 F0008 a OUTPUT L+, L+, L, L-: terminals output b INPUT L, N, PE: terminals input c 13-14: terminals - signalling contact d OUTPUT OK: green LED output voltage OK e OUTPUT LOW: red LED output

More information

ATSU01N232LT soft starter for asynchronous motor - ATSU01-32 A V KW

ATSU01N232LT soft starter for asynchronous motor - ATSU01-32 A V KW Characteristics soft starter for asynchronous motor - ATSU01-32 A - 200..480V - 7.5..15 KW Main Range of product Product or component type Product destination Product specific application Device short

More information

Power supply CP-D 12/2.1

Power supply CP-D 12/2.1 2CDC 271 025 F0t07 a OUTPUT ++/ : terminals output Features Rated output voltage 12 V DC Output voltage adjustable via front face potentiometer OUTPUT Adjust Rated output current 2.1 A Rated output power

More information

Current monitoring relays CM-SRS.1 For single-phase AC/DC currents

Current monitoring relays CM-SRS.1 For single-phase AC/DC currents Data sheet Current monitoring relays CM-SRS.1 For single-phase AC/DC currents The CM-SRS.1 is an electronic current monitoring relay that protects single-phase mains (DC or AC) from over- and undercurrent

More information

Current monitoring relays CM-SRS.2 for single-phase AC/DC currents

Current monitoring relays CM-SRS.2 for single-phase AC/DC currents Data sheet Current monitoring relays CM-SRS.2 for single-phase AC/DC currents For the monitoring of currents in single-phase AC/DC systems, ABB s CM range comprises a wide selection of powerful and compact

More information

Voltage monitoring relay CM-EFS.2 For single-phase AC/DC voltages

Voltage monitoring relay CM-EFS.2 For single-phase AC/DC voltages Data sheet Voltage monitoring relay CM-EFS.2 For single-phase AC/DC voltages The CM-EFS.2 is an electronic voltage monitoring relay that provides reliable monitoring of voltages as well as detection of

More information

Power supply CP-T 48/20.0 Primary switch mode power supply

Power supply CP-T 48/20.0 Primary switch mode power supply Data sheet Power supply CP-T 48/20.0 Primary switch mode power supply The CP-T range of three-phase power supply units is the youngest member of ABB s power supply family. In terms of design and functionality,

More information

Voltage monitoring relays CM-ESS.1 for single-phase AC/DC voltages

Voltage monitoring relays CM-ESS.1 for single-phase AC/DC voltages Data sheet Voltage monitoring relays CM-ESS.1 for single-phase AC/DC voltages For the monitoring of voltages in single-phase AC/DC systems, ABB s CM range comprises a wide selection of powerful and compact

More information

ATSU01N222LT soft starter for asynchronous motor - ATSU01-22 A V KW

ATSU01N222LT soft starter for asynchronous motor - ATSU01-22 A V KW Characteristics soft starter for asynchronous motor - ATSU01-22 A - 200..480 V - 4..11 KW Price* : 195.00 GBP Main Range of product Product or component type Product destination Product specific application

More information

ATS01N103FT soft starter for asynchronous motor - ATS01-3 A V KW

ATS01N103FT soft starter for asynchronous motor - ATS01-3 A V KW Characteristics soft starter for asynchronous motor - ATS01-3 A - 110..480V - 0.55..1.1 KW Main Range of product Altistart 01 Product or component type Product destination Product specific application

More information

Electronic timer CT-SDS.22

Electronic timer CT-SDS.22 CDC 0 F0t07 Features Rated control supply voltage 8 V DC, 0 V AC Single function timer with star delta change over One device includes 7 time ranges (0.0 s 0 min) n/o contacts LEDs for status indication

More information

Power supply CP-D 24/1.3

Power supply CP-D 24/1.3 2CDC 271 027 F0t07 a OUTPUT ++/ : terminals output Features Rated output voltage 24 V DC Output voltage adjustable via front face potentiometer OUTPUT Adjust Rated output current 1.3 A Rated output power

More information

CP-T range Product group picture

CP-T range Product group picture Product group picture /1 ABB Catalog Electronic Products and Relays 1/1 2CDC 110 00 C09 Table of contents CP-T range Product group picture /1 Table of contents /2 Benefits and advantages / Ordering details

More information

QUINT-PS/ 3AC/24DC/10

QUINT-PS/ 3AC/24DC/10 Primary-switched power supply with SFB technology, 3 AC, output current 10 A INTERFACE Data sheet 103131_en_01 1 Description PHOENIX CONTACT - 09/2009 Features QUINT POWER power supply units Maximum system

More information

Power supply CP-E 12/10.0 Primary switch mode power supply Data sheet

Power supply CP-E 12/10.0 Primary switch mode power supply Data sheet 2CDC 271 024 F0008 OUTPUT L+, L+, L-, L-: terminals - output INPUT L, N, PE: terminals - input OUTPUT OK: green LED - output voltage OK OUTPUT LOW: red LED - output voltage too low OUTPUT Adjust: potentiometer

More information

Power supply CP-T 24/20.0 Primary switch mode power supply

Power supply CP-T 24/20.0 Primary switch mode power supply Data sheet Power supply CP-T 24/20.0 Primary switch mode power supply The CP-T range of three-phase power supply units is the youngest member of ABB s power supply family. In terms of design and functionality,

More information

Power supply CP-T 24/10.0 Primary switch mode power supply

Power supply CP-T 24/10.0 Primary switch mode power supply Data sheet Power supply CP-T 24/10.0 Primary switch mode power supply The CP-T range of three-phase power supply units is the youngest member of ABB s power supply family. In terms of design and functionality,

More information

Power supply CP-T 24/40.0 Primary switch mode power supply

Power supply CP-T 24/40.0 Primary switch mode power supply Data sheet Power supply CP-T 24/40.0 Primary switch mode power supply The CP-T range of three-phase power supply units is the youngest member of ABB s power supply family. In terms of design and functionality,

More information

Type 3RW RW40 7. Control electronics Rated values. Terminal. external DC supply (to DIN 19240) through terminals and IN Relay outputs

Type 3RW RW40 7. Control electronics Rated values. Terminal. external DC supply (to DIN 19240) through terminals and IN Relay outputs Function have all the same advantages as the 3RW30/31 soft starters. At the same they come with additional functions and a two-phase control method (Polarity Balancing) that is unique in the rating range

More information

Power supply CP-E 24/2.5

Power supply CP-E 24/2.5 2CDC 271 015 F0t06 a OUTPUT L+, L : terminals output b DC OK: terminal signalling output c INPUT L, N, PE: terminals input d OUTPUT OK: green LED output voltage OK e OUTPUT Adjust: potentiometer adjustment

More information

Content. Monitoring relay pluggable. 1-phase current monitoring relay phase direct-current voltage monitoring relay... 5.

Content. Monitoring relay pluggable. 1-phase current monitoring relay phase direct-current voltage monitoring relay... 5. Content Monitoring relay pluggable 1-phase current monitoring relay... 5.2 1-phase direct-current voltage monitoring relay... 5.6 1-phase voltage monitoring relay... 5.10 3-phase voltage monitoring relay...

More information

Notes: Note1: Efficiency is tested at nominal input and full load at +25 C ambient. Output Voltage 400VAC 400VAC

Notes: Note1: Efficiency is tested at nominal input and full load at +25 C ambient. Output Voltage 400VAC 400VAC Features DIN-Rail Description 2 and 3-phase operation Input voltage range: 320 575VAC Output trim range: 22.5 29.5VDC High electrical strength; high reliability Permanent overload and short-circuit protection

More information

Notes: Note1: Efficiency is tested at nominal input and full load at +25 C ambient. Output Voltage 400VAC 320VAC 360VAC 400VAC 400VAC

Notes: Note1: Efficiency is tested at nominal input and full load at +25 C ambient. Output Voltage 400VAC 320VAC 360VAC 400VAC 400VAC Features DIN-Rail 2 and 3-phase operation Input voltage range: 320 575VAC Output trim range: 22.5 29.5VDC High electrical strength; high reliability Permanent overload and short-circuit protection Parallel

More information

Current monitoring relays CM-SRS.1 for single-phase AC/DC currents

Current monitoring relays CM-SRS.1 for single-phase AC/DC currents Data sheet Current monitoring relays CM-SRS.1 for single-phase AC/DC currents For the monitoring of currents in single-phase AC/DC systems, ABB s CM range comprises a wide selection of powerful and compact

More information

ABB NEW. Three-phase monitoring relays. CM-PVS.31 and CM-PVS.41 Data sheet. Features J. Approvals. Marks. Order data. Order data - Accessories

ABB NEW. Three-phase monitoring relays. CM-PVS.31 and CM-PVS.41 Data sheet. Features J. Approvals. Marks. Order data. Order data - Accessories 2CDC 251 042 F0t08 CM-PVS.31 Features Monitoring of three-phase mains for phase sequence (can be switched off), phase failure, over- and undervoltage Threshold values for over- and undervoltage are adjustable

More information

ATS01N206QN soft starter for asynchronous motor - ATS01-6 A V KW

ATS01N206QN soft starter for asynchronous motor - ATS01-6 A V KW Product datasheet Characteristics ATS01N206QN soft starter for asynchronous motor - ATS01-6 A - 380..415V - 1.5..3 KW Complementary Assembly style Function available Supply voltage limits Main Range of

More information

38 Series - Relay interface modules A

38 Series - Relay interface modules A 38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 A Common features Instant ejection of relay by plastic retaining clip Integral coil indication and protection circuit EMR Electromechanical Relays

More information

38 Series - Relay interface modules A

38 Series - Relay interface modules A 38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 A Common features Instant ejection of relay by plastic retaining clip Integral coil indication and protection circuit 6.2 mm wide EMR - DC, AC or AC/DC

More information

Electronic timer CT-AHS.22 OFF-delayed with 2 c/o (SPDT) contacts

Electronic timer CT-AHS.22 OFF-delayed with 2 c/o (SPDT) contacts Data sheet Electronic timer CT-AHS.22 OFF-delayed with 2 c/o (SPDT) contacts The CT-AHS.22 is an electronic timer from the CT-S range with OFF-delay and 10 time ranges. All electronic timers from the CT-S

More information

QUINT-PS AC/24DC/40

QUINT-PS AC/24DC/40 Power supply unit INTERFACE Data sheet 102315_en_02 1 Description PHOENIX CONTACT 2010-04-23 Features QUINT POWER power supply units for plant and special engineering reliably start heavy loads with high

More information

Electronic timer CT-TGD.22

Electronic timer CT-TGD.22 2CDC 251 097 F0t06 a Rotary switch for the preselection of the time range of the ON time b Potentiometer with direct reading scale for the fine adjustment of the ON time c Rotary switch for the preselection

More information

Solid State Relays 1-Phase, Zero Cross or Instant On Switching 25 AAC, 230 VAC with LED and Built-in Transil Types RF1A, RF1B

Solid State Relays 1-Phase, Zero Cross or Instant On Switching 25 AAC, 230 VAC with LED and Built-in Transil Types RF1A, RF1B Solid State Relays 1-Phase, Zero Cross or Instant On Switching 25 AAC, 230 VAC with LED and Built-in Transil Types RF1A, RF1B AC switching Solid State Relay Switching through back to back thyristors Long

More information

Three-phase monitoring relays

Three-phase monitoring relays 2CDC 251 046 F0t08 Features Monitoring of three-phase mains for phase sequence, phase failure, phase unbalance Threshold value for phase unbalance adjustable as absolute value Tripping delay can be adjusted

More information

QUINT-PS-24DC/24DC/10

QUINT-PS-24DC/24DC/10 QUINT-PS-24/24/10 QUINT - converter, primary switched mode, input: 24 V, output: 24 V /10 A INTERFACE Data Sheet PHOENIX CONTACT - 02/2006 Description The QUINT - converter 24 V/10 A converts the voltage

More information

Soft starters with internal by-pass

Soft starters with internal by-pass www.ic-electronic.com Soft starters with internal by-pass Soft starter for 3-phase motors with integrated by-pass Rated operational voltage 200...480VAC Rated operational current: 30A (rms) 51A inside

More information

RE7MY13MW time delay relay 8 functions s V AC DC - 2OC

RE7MY13MW time delay relay 8 functions s V AC DC - 2OC Characteristics time delay relay 8 functions - 0.05..1 s - 240 V AC DC - 2OC Main Range of product Product or component type Contacts type and composition Component name Time delay type Time delay range

More information

ABB 1. Multifunctional three-phase monitoring relays. CM-MPS.11, CM-MPS-21, CM-MPS.31 and CM-MPS.41 Data sheet. Features. Approvals. Marks.

ABB 1. Multifunctional three-phase monitoring relays. CM-MPS.11, CM-MPS-21, CM-MPS.31 and CM-MPS.41 Data sheet. Features. Approvals. Marks. 2CDC 251 048 F0t08 CM-MPS.11 2CDC 251 049 F0t08 CM-MPS.21 2CDC 251 050 F0t08 CM-MPS.31 2CDC 251 051 F0t08 CM-MPS.41 R/T: yellow LED - relay status, timing F1: red LED - fault message F2: red LED - fault

More information

CP-T range Benefits and advantages

CP-T range Benefits and advantages Benefits and advantages Characteristics Rated output voltages V, V DC Output voltage adjustable via front-face rotary potentiometer OUTPUT Adjust Rated output currents 5 A, 10 A, A, A Rated output powers

More information

ABB NEW. Multifunctional three-phase monitoring relays. CM-MPS.23 and CM-MPS.43 Data sheet. Features J. Approvals. Marks.

ABB NEW. Multifunctional three-phase monitoring relays. CM-MPS.23 and CM-MPS.43 Data sheet. Features J. Approvals. Marks. 2CDC 251 052 F0t08 CM-MPS.23 2CDC 251 053 F0t08 CM-MPS.43 - relay status, timing - fault message - fault message Adjustment of the tripping delay t V Adjustment of the threshold value for overvoltage 6

More information

QUINT-PS/ 3AC/24DC/40

QUINT-PS/ 3AC/24DC/40 Primary-switched power supply unit with SFB technology, 3 AC, output current 40 A INTERFACE Data sheet 103133_en_00 1 Description PHOENIX CONTACT - 07/2009 Features QUINT POWER power supply units Maximum

More information

22/10/2012

22/10/2012 22.5 mm DIN rail mounting TUR1 Part number 88865105 Multi-function or mono-function Multi-range Multi-voltage Screw or spring terminals LED status indicator Option of connecting an external power supply

More information

Three-phase monitoring relays CM-PVS CM-PVS.31, CM-PVS.41 and CM-PVS.81

Three-phase monitoring relays CM-PVS CM-PVS.31, CM-PVS.41 and CM-PVS.81 Data sheet Three-phase monitoring relays CM-PVS CM-PVS.31, CM-PVS.41 and CM-PVS.81 The three-phase monitoring relays CM-PVS.x1 monitor the phase parameters phase sequence, phase failure as well as over-

More information

77 Series - Modular Solid State Relay 5 A. Features. Timers and Monitoring relays

77 Series - Modular Solid State Relay 5 A. Features. Timers and Monitoring relays Series - Modular Solid State Relay 5 A 77 Features 77.01.x.xxx.8050 77.01.x.xxx.8051 5 A modular SSR, 1 NO output 17.5 mm housing 60 to 240 V AC output (with back to back SCR) 5 kv (1.2/50 μs) insulation

More information

ADC5000 SERIES. AC/DC Switch Mode Power Supplies and Rectifiers for Industrial and Telecom Applications. 60W, 125W and 250 W

ADC5000 SERIES. AC/DC Switch Mode Power Supplies and Rectifiers for Industrial and Telecom Applications. 60W, 125W and 250 W ADC5000 SERIES AC/DC Switch Mode Power Supplies and Rectifiers for Industrial and Telecom Applications 60W, 125W and 250 W Input voltage 230/115 VAC voltages 12, 24, 36 or 48 VDC Statistical MTBF >3 000

More information

ABB 1. Multifunctional three-phase monitoring relays. CM-MPN.52, CM-MPN.62 and CM-MPN.72 Data sheet. Features. Approvals. Marks.

ABB 1. Multifunctional three-phase monitoring relays. CM-MPN.52, CM-MPN.62 and CM-MPN.72 Data sheet. Features. Approvals. Marks. 2CDC 251 054 F0t08 CM-MPN.52 2CDC 251 055 F0t08 CM-MPN.62 2CDC 251 056 F0t08 CM-MPN.72 Features Monitoring of three-phase mains for phase sequence (can be switched off), phase failure, over- and undervoltage

More information

CM-MPS.11, CM-MPS-21, CM-MPS.31 and CM-MPS.41 Data sheet. UL 508, CAN/CSA C22.2 No.14 GL GOST CB scheme CCC

CM-MPS.11, CM-MPS-21, CM-MPS.31 and CM-MPS.41 Data sheet. UL 508, CAN/CSA C22.2 No.14 GL GOST CB scheme CCC 2CDC 251 048 F0t08 CM-MPS.11 2CDC 251 049 F0t08 CM-MPS.21 Features Monitoring of three-phase mains for phase sequence (can be switched off), phase failure, over- and undervoltage as well as phase unbalance

More information

Solid-state Timer H3DE

Solid-state Timer H3DE Solid-state Timer H3DE DIN-rail Mounted, Standard 22.5-mm Width Timer Range A wide AC/DC power supply range (24 to 230 VAC/DC) reduces the number of timer models kept in stock. (except for H3DE-H) 12-VDC

More information

08/07/2015

08/07/2015 17.5 mm - 1 Solid State Relay 0.7A MUS2 Part number 88827004 Multi-function or mono-function Multi-range Multi-voltage Screw or spring terminals LED status indicator (relay version) Possibility of external

More information

Electronic timer CT-MFS.21

Electronic timer CT-MFS.21 2CDC 251 053 F0t07 a Rotary switch for the preselection of the time range b Potentiometer with direct reading scale for the fine adjustment of the time delay c Rotary switch for the preselection of the

More information

MINI-PS AC/24DC/1.3

MINI-PS AC/24DC/1.3 Power supply unit INTERFACE Data sheet 102894_en_03 1 Description PHOENIX CONTACT 2015-11-17 Features MINI POWER power supplies for MCR technology In measurement and control technology (MCR), modular electronics

More information

CP-E range Benefits and advantages

CP-E range Benefits and advantages Benefits and advantages Characteristics Output voltages 5 V, 12 V, 2 V, 8 V DC Adjustable output voltages Benefits Signalling output/contact Output currents 0.625 A / 0.75 A / 1.25 A / 2.5 A / A / 5 A

More information

Three-phase monitoring relay CM-PFS

Three-phase monitoring relay CM-PFS Data sheet Three-phase monitoring relay CM-PFS The CM-PFS is a three-phase monitoring relay that is used to monitor three phase mains for incorrect phase sequence and phase failure. All devices are available

More information

Switching power supplies CP range, Linear power supplies CP-L range. Content

Switching power supplies CP range, Linear power supplies CP-L range. Content CP range, Linear power supplies CP-L range Content Switching power supplies, primary switch mode, CP range Benefits and advantages... 136 Approvals... 137 Ordering details... 138 Technical data... 11 Dimensional

More information

Solid-state Twin Timer

Solid-state Twin Timer Solid-state Twin Timer -F Operates in flicker- or flicker- start mode with one Unit. Independent - and -time settings. Combinations of long - or -time and short - or -time setting are possible. Long time

More information

PHOENIX CONTACT - 05/2008. DANGER OF EXPLOSION! Remove an item only when it is not connected to power or if it is located in the non-explosive area.

PHOENIX CONTACT - 05/2008. DANGER OF EXPLOSION! Remove an item only when it is not connected to power or if it is located in the non-explosive area. Primary-switched power supply with SFB technology, 1 AC, output current 20 A INTERFACE Data Sheet 103129_en_01 PHOENIX CONTACT - 05/2008 1 Description QUINT POWER power supply units highest system availability

More information