1 Revision No. : 03 Page 1 of 5 1 Place where equipment to be supplied 1. CPRI, Hyderabad 2. CPRI, Bhopal 3. CPRI, Noida 4. EMC, Trivandrum 1 set at each location 2 Scope (supply / supply & Installation / suply, installation & training) Pre-qulaification criteria Supply, Installation, commisioning and Training The bidder must have submitted a similar equipment to national or international laboratories for the same purpose and the proof of supply must be provided. 3 Equipment Name Servo controlled voltage stabilizer 4 sets each( 1 set at each location )
2 Revision No. : 03 Page 2 of 5 4 Introduction AC power source which should provide stable and pure sinusoidal wave supply with adjustable frequency from 45 Hz to 60 Hz and low distortion as per IS (Part2) standard. The scope is to test LED lamps and luminaries as per IS 16102, Part-2:2012 standard. 5 Description AC power source which should provide stable and pure sinusoidal wave supply with adjustable frequency from 45 Hz to 60 Hz and low distortion 6 Operating voltage 295 V to 465 V, 50Hz ± 3 Hz and 3 phase AC supply 7 Capacity 45 kva 8 Cooling Oil cooled or appropriate 9 Output voltage 230/250 V ± 1 %(between neutral and each phase) 10 Accuracy ±1% or better
3 Revision No. : 03 Page 3 of 5 11 Efficiency Above 98% 12 Control circuit Micro controlled segment 13 Motor drive Heavy duty AC synchronous motor 14 Correction rate 70 V/ sec for phase to phase 15 Duty cycle Continuous 16 Protections Under voltage & Over voltage, overload/ Short Circuit 17 Panel Indications Digital display, Output voltage reading, input voltage reading, load reading, high cut off, low cut off and phase reversal should be provided. 18 Accessories Oil tank with transformer oil 19 Stabilizer standard As per IS 9815
4 Revision No. : 03 Page 4 of 5 20 Calibration Calibration certificates from NABL or its equivalent accredited calibration agency shall be furnished along with the equipment. 21 Documentation: Operating manuals containing schematic diagrams, service details, list of spare parts, etc to be provided with the equipment. 22 Training Training shall be provided by expert people to respective staff after commissioning at following locations:- 1. CPRI, Hyderabad 2. CPRI, Bhopal 3. CPRI, Noida 4. EMC, Trivandrum Duration of training should be one day (maximum 2 days) for 2 respective officials. 23 Guarantee Equipment should be guaranteed for a period of 1 year from date of installation at site.
5 Revision No. : 03 Page 5 of 5 24 Pre-dispatch inspection PDI will be carried by CPRI officials at manufacturer's premises, all expenditure will repect to travel, accomodation and food will be borne by CPRI. PN: 1) Bidder shall indicate complete details/information how the CPRI GTP are complied with against each and every specification parameters & mere statement of 'complied' do not suffice the requirement. 2)A detailed technical/catalogue/literature/phamplet and any other details shall be submitted in hard copy in a sealed cover superscribing enquiry number and due date so as to reach the following address within the due date and time. 3) The Indian representative of the foreign/overseas firms shall submit the Letter of Authorization issued by their principals. 4)The bidder shall submit the quotation / offer in the above prescribed format of Section IA, IB and II only. Informations any other forms shall shall be rejected. Address : Joint Director (Purchase), Purchase Authrity, Central Power Research Institute, Sadashiva Nagar P.O., P.Box.No.8066, Bengaluru Telefax: , purchase@cpri.in, web :
To be completed by the Bidder. Sl.No. Parameters CPRI Specification / Requirements Qty
Revision N : 03 Issue No : 2 Dt of Revis : 25.07.207 Issue Dt. : 30.06.2003 Page No. : of 5 Issued by : P A CENTRAL POWER RESEARCH INSTITUTE, BHOPAL, Web: www.cpri.in, www.tenderwizard.com/cpri, Telefax:
More informationSI.No Parameters CPRI Specification/Requirements To be Completed by the Bidder Guaranteed Technical
Section II Technical Specifications Tender enquiry no. : STDS/12-1/2016-17/PUR/STL/A-1849 Name of the equipment : SPECIFICATIONS OF SYSTEM FOR CONDUCTING DETERMINATION OF ERRORS TEST ON INSTRUMENT TRANSFORMERS
More informationTECHNICAL SPECIFICATIONS for 300KV CONSTANT POTENTIAL X RAY EQUIPMENT (for industrial applications) S. No. PARTICULARS BHEL SPECIFICATIONS
TECHNICAL SPECIFICATIONS for 300KV CONSTANT POTENTIAL X RAY EQUIPMENT (for industrial applications) BIDDER s OFFER S. No. PARTICULARS BHEL SPECIFICATIONS 1.0 Area of Application The 300kV Constant potential
More informationBharat Heavy Electricals Limited (High Pressure Boiler Plant) Tiruchirappalli , TAMIL NADU, INDIA MATERIALS MANAGEMENT / CAPITAL EQUIPMENT
An ISO 9001 Company Bharat Heavy Electricals Limited (High Pressure Boiler Plant), TAMIL NADU, INDIA MATERIALS MANAGEMENT / CAPITAL EQUIPMENT ENQUIRY NOTICE INVITING TENDER Phone: +91 431 257 7653 Fax
More informationPURCHASE DIVISION DEPARTMENT QUALITY MANUAL Revision No. : 02 Issue No: : 2 Dt of Revision : Issue Dt. :
Section : 0 Document : DQM-01 Topic : FORMAT 6 OF PROCUREMENT PROCEDURE OF CPRI (NON-WORKS) Section I(B)-Technical Specification Tender Enquery No PUR/UARC-02/14-15 Name of the Equipment: Damped Oscillatory
More information/TENDER ENQUIRY NO :ENQ/17-18/005148/BP26(07) Delivery Schedule. Test Certificate
A.O Building, Barsingsar-440, Bikaner District, Rajasthan, India /TENDER ENQUIRY NO :ENQ/7-8/00548/BP6(07) /DATE :7/0/08 /Page - Due Date of Cover-I Opening : /04/08 :00:00 hrs. IST (Check NLC eproc website
More informationMANAGEMENT COMPLEX / GST:33AAACN1121C1ZG CIN:L93090TN1956GOI /TENDER ENQUIRY NO :ENQ/18-19/003497/MM15(02) /DATE
NLC INDIA LIMITED (formerly Neyveli Lignite Corporation Limited) ('NAVARATNA'-Government of India Enterprise) MATERIALS MANAGEMENT COMPLEX Dr. Rajendra Prasad Road,Block-27,Neyveli-607807.Tamilnadu,India.
More informationTECHNICAL SPECIFICATION OF LT SHACKLE BOLT (G. I. BOLT) WITH NUT AND SPRING WASHER
TECHNICAL SPECIFICATION OF LT SHACKLE BOLT (G. I. BOLT) WITH NUT AND SPRING WASHER 1.0 SCOPE: This specification covers the manufacture, testing at works and supply of G. I. Bolts with Nut and Spring Washer
More informationIssue No : 2 Dt of Revision :
PURCHASE DIVISION DEPARTMENT QUALITY MANUAL Revision No. : 02 Issue No : 2 Dt of Revision : 17.9.2012 Issue Dt. : 30.06.2003 Page No. : 1 OF 3 Issued by : Q A Section : 0 Document : DQM-01 Topic : FORMAT
More informationSection Meetings Section Material and Equipment. None Required
January 2000 Page 1 of 8 PART 1 GENERAL 1.01 OTHER CONTRACT DOCUMENTS 1.02 DESCRIPTION OF WORK 1.03 RELATED WORK PART 2 PRODUCTS The General Conditions of the Contract, General Requirements and Supplemental
More informationLOCOMOTIVE ENGINEERING DEPTT.
SHEET 1 OF 9 SUBJECT: FOR DESIGN MANUFACTURING INSTALLATION OF FIXTURES FOR MANUFACTURING OF SHELL ASSEMBLY OF WAG7 LOCOMOTIVE Enclosures: Rev Date Prepared Rev Date Prepared Rev Date Prepared Approved
More informationNEO TELE-TRONIX PVT. LTD. 6/7 Bijoygarh, Kolkata , Tel : ; Fax :
NEO TELE-TRONIX PVT. LTD. 6/7 Bijoygarh, Kolkata - 700 032, Tel : 033 2477 3126; Fax : 033 2477 2403 www.ntplindia.com SPECIFICATION NTPL MAKE MICRO-CONTROLLER BASED AUTOMATIC 50KV/10A AC HIGH VOLTAGE
More informationTechnical Specifications for Portable 3-Ø Power Analyzer
Technical Specifications for Portable 3-Ø Power Analyzer SCOPE: This specification covers the general specifications of 3-phase power analyzer that can be used to measure the no load and full load losses
More informationTECHNICAL SPECIFICATION
TECHNICAL SPECIFICATION 1. SCOPE : TECHNICAL SPECIFICATION FOR LIGHTNING ARRESTORS 1.1. This Specification covers design, manufacture, testing at manufacturer's Works, packing, supply, delivery of 42 KV
More informationInvitation of quotation for Camera At All India Institute of Medical Sciences, Jodhpur
Invitation of quotation for Camera At All India Institute of Medical Sciences, Jodhpur Inquiry No.: : Admin/Gen/16-02(ii)/2017-AIIMS.JDH Inquiry Issue Date : 20 th May, 2017 Last Date of Submission : 26
More informationTechnical Specification. for 1.1 KV Copper Control Cable
WEST BENGAL STATE ELECTRICITY DISTRIBUTION COMPANY LIMITED (A Govt. of West Bengal Enterprise) Office of the Chief Engineer, Procurement & Contracts Department Vidyut Bhavan, 4 th. floor, Bidhannagar,
More information2.14 Main Cable Type HO7RN-F4G10-15 Metres each Chiller Tank Capacity- 75 Litres Compressor- 3.5 Tons Refrigeration type
PAGE 2 of 6 2.14 Main Cable Type HO7RN-F4G10-15 Metres each 2.15 (a) O/P Voltage-350V(Max.) (b) O/P Current 150A(Max.) 2.16 Chiller Tank Capacity- 75 Litres Compressor- 3.5 Tons Refrigeration type 2.17
More informationIN THE MATTER OF AN APPEAL BY ) LARRY SHAHEEN OF REGIONAL ) CONSTRUCTION AND DESIGN ) ORDER REGARDING THE NORTH CAROLINA ) ELECTRICAL CODE )
STATE OF NORTH CAROLINA COUNTY OF WAKE BEFORE THE NORTH CAROLINA BUILDING CODE COUNCIL IN THE MATTER OF AN APPEAL BY ) LARRY SHAHEEN OF REGIONAL ) CONSTRUCTION AND DESIGN ) ORDER REGARDING THE NORTH CAROLINA
More informationSPECIFICATION OF SOLAR CELL TESTER
SPECIFICATION OF SOLAR CELL TESTER A. Purpose: This equipment is to be used for testing of mono and multi crystalline silicon solar cells under standard testing conditions. The equipment shall be interfaced
More informationPROCUREMENT OF GOODS UNDER OPEN TENDER PROCEDURE
IFB NO. KGEC/DST-WB/EE /2018-19/995 PROCUREMENT OF GOODS UNDER OPEN TENDER PROCEDURE Kalyani Government Engineering College Kalyani 741 235; Nadia, West Bengal 1 Government of West Bengal Office of the
More informationSpecification for a Fully Automatic Meter Test Equipment for testing Three-phase/Single/Transformer operated/ reference Standard energy meters.
Specification for a Fully Automatic Meter Test Equipment for testing Three-phase/Single/Transformer operated/ reference Standard energy meters. Scope: This specification defines the requirement of a Three
More informationNATIONAL POWER TRAINING INSTITUTE (WR) (Ministry of Power, Govt. of India) NAGPUR TENDER DOCUMENT SUPPLY OF DRAWING TABLES AND STOOLS
NATIONAL POWER TRAINING INSTITUTE (WR) (Ministry of Power, Govt. of India) NAGPUR-440022 TENDER DOCUMENT SUPPLY OF DRAWING TABLES AND STOOLS At NPTI (WR), NAGPUR, MAHARASHTRA 1 NATIONAL POWER TRAINING
More informationThe RSM shall be extensively used in field & laboratory for verification of the accuracy of all types of single-phase energy meters.
TECHNICAL SPECIFICATION FOR PORTABLE ELECTRONIC REFERENCE STANDARD METER (ERS) FOR TESTING OF SINGLE PHASE KILOWATT HOUR ENERGY METERS (ACCURACY CLASS 0. 2) 1. SCOPE: The specification covers the requirement
More informationOrganisation Internationale de Métrologie Légale
Organisation Internationale de Métrologie Légale INTERNATIONAL RECOMMENDATION Sound level meters Sonomètres OIML R 58 Edition 1998 (E) CONTENTS Foreword... 3 1 Scope... 4 2 Construction and maximum permissible
More informationANNEXURE-I. Documents to be uploaded 1 Certificate of Registration with Industries 2 VAT Certificate 3 Service Tax Certificate
ANNEXURE-I Documents to be uploaded 1 Certificate of Registration with Industries 2 VAT Certificate 3 Service Tax Certificate 4 Excise Duty Registration Certificate 5 Pan Card 6 Approved Vendor Certificates
More informationCOSPAS-SARSAT ACCEPTANCE OF 406 MHz BEACON TYPE APPROVAL TEST FACILITIES
COSPAS-SARSAT ACCEPTANCE OF 406 MHz BEACON TYPE APPROVAL TEST FACILITIES C/S T.008 Issue 2 T8NOV05 i C/S T.008 - Issue 2 COSPAS-SARSAT ACCEPTANCE OF 406 MHz BEACON TYPE APPROVAL TEST FACILITIES History
More informationTECHNICAL SPECIFICATION FOR G. I. WIRE (4MM)
1. SCOPE: TECHNICAL SPECIFICATION FOR G. I. WIRE (4MM) This Specification provides for manufacture, testing before dispatch at manufacturer's work and supply and delivery of 4mm solid heavily coated Galvanized
More informationQUOTATION. Procurement of Equipments for Physics Laboratory
Notification No.: NITPY/PHY/LAB/Q-0/014-15 31.1.014 QUOTATION Procurement of Equipments for Physics Laboratory National Institute of Technology Puducherry invites sealed quotations from the reputed vendors/manufacturers
More informationTECHNICAL SPECIFICATION OF PORTABLE ELECTRONIC REFERENCE STANDARD ENERGY METER (ERS METER) FOR T E S T I N G O F HT THREE PHASE ENERGY METERS:-
TECHNICAL SPECIFICATION OF PORTABLE ELECTRONIC REFERENCE STANDARD ENERGY METER (ERS METER) FOR T E S T I N G O F HT THREE PHASE ENERGY METERS:- 1.0 SCOPE:- A lightweight electronic precision portable energy
More informationCertificate by the Architect: Certified that no addition and deletion has been made to the tender documents downloaded from the IIT Madras web site.
INDIAN INSTITUTE OF TECHNOLOGY MADRAS ENGINEERING UNIT CHENNAI 600 036 NOTICE INVITING TENDERS FOR APPOINTMENT OF ARCHITECTURAL CONSULTANT No: 35/ ARC / 2013 14 TECHNICAL BID COVER 2 NAME OF WORK: Providing
More informationPROCEDURE FOR INSPECTION OF ELECTRICAL INSTALLATIONS ABOVE 250KVA
PROCEDURE FOR INSPECTION OF ELECTRICAL INSTALLATIONS ABOVE 250KVA Generally inspection of electrical installations is carried out under Regulation-30 (Periodical inspection & testing) & Regulation-43 (Approval
More informationWRIST ARTHROSCOPY SYSTEM
DESCRIPTION 1 1 lot 10,648,751.67 Brand new, not reconditioned including its Parts & Accessories 1. Wrist Arthroscope a. HD wide angle 30-degree small joint arthroscope i. One (1) short scope (1 piece)
More informationELECTRICAL R&D LABORATORY SPECIFICATION FOR TESTS OF COMPRESSION AND MECHANICAL CONNECTORS AND TERMINAL LUGS FOR POWER CABLES WITH COPPER
Israel Electric Corp. Ltd. Strategic Resources Group Planning Development & Technology Division ELECTRICAL R&D LABORATORY SPECIFICATION FOR TESTS OF COMPRESSION AND MECHANICAL CONNECTORS AND TERMINAL LUGS
More informationPROCUREMENT OF SERVO CONTROLLED VOLTAGE STABILIZER FOR STPI-NASIK
PROCUREMENT OF SERVO CONTROLLED VOLTAGE STABILIZER FOR STPI-NASIK Sealed quotations are invited under Two-Bid system from reputed agencies, either by themselves or as a joint venture/consortium/partnership
More informationCertificate of Accreditation
PERRY JOHNSON LABORATORY ACCREDITATION, INC. Certificate of Accreditation Perry Johnson Laboratory Accreditation, Inc. has assessed the Laboratory of: 241 Riverview Avenue. Newton MA 02466 505 Boul.du
More informationTPS 49 EDITION 2 JUNE 2009
TPS 49 EDITION 2 JUNE 2009 Interim arrangements & guidance on the interpretation of IEC 61672 Sound Level Meters - Periodic Tests CONTENTS SECTION PAGE 1 Purpose and duration 2 2 Statement 2 3 Specific
More informationPERFORMANCE SPECIFICATION SHEET
INCH-POUND MIL-PRF-83536/32D 03 October 2017 SUPERSEDING MIL-PRF-83536/32C 21 April 2015 PERFORMANCE SPECIFICATION SHEET RELAYS, ELECTROMAGNETIC, ESTABLISHED RELIABILITY, 3PDT, 25 AMPERES (RESISTIVE),
More informationPhysical Properties Measurement System (PPMS): Detailed specifications: Basic unit cryogen- free
Physical Properties Measurement System (PPMS): A Cryogen-free Physical Properties Measurement system that operates over a wider range of temperature and magnetic fields: fully automated/computer controlled
More informationCOMBINED METERING TRANSFORMERS (OUT DOOR TYPE) FOR 11kV & 33kV SYSTEMS
006: 2008 CEB SPECIFICATION COMBINED METERING TRANSFORMERS (OUT DOOR TYPE) FOR 11kV & 33kV SYSTEMS CEYLON ELECTRICITY BOARD SRI LANKA Specification for COMBINED METERING TRANSFORMERS (OUTDOOR TYPE) FOR
More information1.1_KV PVC insulated PVC sheathed multicore Aluminium Cable (armoured & unarmoured)
WEST BENGAL STATE ELECTRICITY DISTRIBUTION COMPANY LIMITED (A Govt. of West Bengal Enterprise) Office of the Chief Engineer, Procurement & Contracts Department Vidyut Bhavan, 4 th. floor, Bidhannagar,
More informationPOTENTIAL TRANSFORMER
POTENTIAL TRANSFORMER September 2017 Engineering Department WEST BENGAL STATE ELECTRICITY TRANSMISSION COMPANY LIMITED Regd. Office: VidyutBhawan, Block DJ, Sector-II, Bidhannagar, Kolkata 700091. CIN:
More informationPERFORMANCE SPECIFICATION SHEET ELECTRON TUBE, POWER TYPE 8660
INCH-POUND MIL-PRF-1/1648D 23 September 2014 SUPERSEDING MIL-PRF-1/1648C w/amendment 1 10 April 2008 DESCRIPTION: Tetrode, ceramic-metal. See figure 2. Mounting position: Any. PERFORMANCE SPECIFICATION
More informationE-5 PROCUREMENT OF GOODS UNDER NATIONAL SHOPPING PROCEDURES
E-5 PROCUREMENT OF GOODS UNDER NATIONAL SHOPPING PROCEDURES (For Contracts valued less than the equivalent of US $30,000 each) INVITATION FOR QUOTATIONS FOR SUPPLY OF EQUIPMENT UNDER NATIONAL SHOPPING
More informationTHE KENYA POWER AND LIGHTING CO. LTD. SPECIFICATIONS for IMPULSE VOLTAGE TEST EQUIPMENT
THE KENYA POWER AND LIGHTING CO. LTD SPECIFICATIONS for IMPULSE VOLTAGE TEST EQUIPMENT NAME DESIGNATION SIGNATURE DATE Compiled by Ephantus Nyagah Ag. Senior Engineer Checked by Eng. Thagichu Kiiru Deputy
More information012: 2015 CEB SPECIFICATION GALVANIZED STEEL WIRE (EXCEPT SHIELDING WIRE FOR TOWER LINE APPLICATION)
012: 2015 CEB SPECIFICATION GALVANIZED STEEL WIRE (EXCEPT SHIELDING WIRE FOR TOWER LINE APPLICATION) CEYLON ELECTRICITY BOARD SRI LANKA Telephone: +94 11 232 8051 Fax: +94 11 232 5387 CONTENTS Page 1.0
More informationPURCHASE SPECIFICATIONS 500KVA DRY TYPE TRANSFORMER FOR OIL RIG APPLICATIONS
PURCHASE SPECIFICATIONS OF 500KVA DRY TYPE TRANSFORMER FOR OIL RIG APPLICATIONS SPECIFICATION NO. : OR12423 REVISION NO. : Rev 00 DATE : 01.03.2011 DISTRIBUTION : PI - 4 copies O/C - 1 copy PREPARED BY
More informationUniversity Visvesvaraya College of Engineering
University Visvesvaraya College of Engineering K.R.Circle, -560001 INVITATION FOR QUOTATION TEQIP-II/2013/KA2G01/Shopping/25 29-Nov-2013 To, Sub: Invitation for Quotations for supply of Goods Dear Sir,
More informationPlant Client Contract Code Document ID Contract No. TECHNICAL SPECIFICATIONS DC SHUNT Rev 00 Page 1 of 2
TECHNICAL SPECIFICATIONS Rev 00 Page 1 of 2 0 IFI Release for Enquiry 14/12/18 SSS 14/12/18 HGG 14/12/18 RBU - Rev. Status Description Date Prepared Date Checked Date Approved AC Based on: PIN-QMC-03-F101
More informationOIML R 130 RECOMMENDATION. Edition 2001 (E) ORGANISATION INTERNATIONALE INTERNATIONAL ORGANIZATION. Octave-band and one-third-octave-band filters
INTERNATIONAL RECOMMENDATION OIML R 130 Edition 2001 (E) Octave-band and one-third-octave-band filters Filtres à bande d octave et de tiers d octave OIML R 130 Edition 2001 (E) ORGANISATION INTERNATIONALE
More informationINTERNATIONAL OIML R 103 RECOMMENDATION
INTERNATIONAL OIML R 103 RECOMMENDATION Edition 1992 (E) Measuring instrumentation for human response to vibration (with reference to International Standards 8041 and 5347 of the International Organization
More informationUnited Nations Development Programme
Tax on Price Quotation Payment Terms (max. advanced payment is 20% of total price) must be inclusive of VAT and other applicable indirect taxes must be exclusive of VAT and other applicable indirect taxes
More informationTCN 01. Page No. 1 of 2 Ref: PSER:SCT:ABJ:T1178:TCN-01 Date:
TCN 01 Page No. 1 of 2 Ref: PSER:SCT:ABJ:T1178:TCN-01 Date: 21-02-2011 Sub Tender Change Notice (TCN- 01). Job Identification & Receipt of materials, Erection, Testing, Commissioning, Handing over etc
More informationSingle-Phase Mini Pad-Mounted Transformer Specification: Energy+ MPDL
Single-Phase Mini Pad-Mounted Transformer Specification: Energy+ MPDL Issued by: Approved by: Engineering Department Energy+ Inc. September 2016 Shawn Jackson, P.Eng. Approval is given in accordance with
More informationThe Torxis Linear Servo meets the following environmental conditions:
Page: 1 1. PRODUCT DESCRIPTION The Torxis Linear Servo is the second generation of linear servos provided by GearWurx. This product features internal position sensing, and closed loop position control.
More informationOrganisation Internationale de Métrologie Légale
Organisation Internationale de Métrologie Légale INTERNATIONAL RECOMMENDATION Integrating-averaging sound level meters Sonomètres intégrateurs-moyenneurs OIML R 88 Edition 1998 (E) CONTENTS Foreword...
More informationMaharashtra State Electricity Distribution Co. Ltd.
Maharashtra State Electricity Distribution Co. Ltd. SPECIFICATION NO. MSEDCL/ DIST:MSC-III/LT CAP/1/2009/R2(071009) SPECIFICATIONS FOR APP TYPE L.T. CAPACITOR UNITS OF 25 / 30 KVAR CAPACITY (FOR 63 / 100
More informationDNVGL-CP-0338 Edition October 2015
CLASS PROGRAMME DNVGL-CP-0338 Edition October 2015 The electronic pdf version of this document, available free of charge from http://www.dnvgl.com, is the officially binding version. FOREWORD DNV GL class
More informationTABLE OF CONTENTS. 1.0 Scope. 2.0 References. 3.0 Definitions. 4.0 Submission and Design Requirements. 5.0 Materials 5.1 General 5.
1.0 Scope 2.0 References 3.0 Definitions 4.0 Submission and Design Requirements 5.0 Materials 5.1 General 5.2 Marking 6.0 Equipment 7.0 Production 7.1 Steel Octagonal Poles 7.2 Base Plate 7.3 Top Cap 7.4
More informationNZ China EEEMRA. Topics:
NZ China EEEMRA Topics: Mutual Recognition Agreements (MRAs) China Compulsory Certification (CCC) system EEEMRA Advantages of the EEEMRA Beyond the EEEMRA Peter Morfee Principal Technical Advisor EnergySafety
More informationSUPPLY OF CARRIER PROTECTION COUPLER TYPE NSD-50
(I) GENERAL : Indoor PLCC Equipments are required for important 400KV, 220KV and 132KV Sub/station for Speech, Data Transmission, Protection and Teleprinter Links. (II) GENERAL REQUIREMENT : The equipments
More information36kV VOLTAGE TRANSFORMERS (OUTDOOR TYPE)
CEB STANDARD 022 : 1994 Specification for 36kV VOLTAGE TRANSFORMERS (OUTDOOR TYPE) CEYLON ELECTRICITY BOARD SRI LANKA Specification for 36kV VOLTAGE TRANSFORMERS (OUTDOOR TYPE) CEB Standard 022 : 1994
More informationDESIGN PRACTICE NOTE DESIGN/REVIEW REQUIREMENTS FOR TRACTION BONDING PLAN
Approval Amendment Record Approval Date Version Description 01/04/2014 1 Initial Issue under MTM PRINTOUT MAY NOT BE UP-TO-DATE; REFER TO METRO INTRANET FOR THE LATEST VERSION Page 1 of 7 Table of Contents
More informationDEPARTMENT OF ARCHITECTURE
DEPARTMENT OF ARCHITECTURE Web : www.nitt.edu Phone : 0431-2503001 Short Tender Notification No.: NITT/ARCH/04/2012/ DRAWING TABLE Dated : 19-04 -2012 (Retender Those previously quoted for this tender
More informationSECTION-I (G.I.PLAIN WIRE) TECHNICAL SPECIFICATION FOR G. I. WIRE
SECTION-I (G.I.PLAIN WIRE) TECHNICAL SPECIFICATION FOR G. I. WIRE 1. SCOPE :- This Specification provides for manufacture, testing before dispatch at manufacturer's work and supply and delivery of 3.15mm
More informationMIL-PRF-83536/5C 08 June 2010 SUPERSEDING MIL-PRF-83536/5B 04 December 2008 PERFORMANCE SPECIFICATION SHEET
INCH-POUND MIL-PRF-83536/5C 08 June 2010 SUPERSEDING MIL-PRF-83536/5B 04 December 2008 PERFORMANCE SPECIFICATION SHEET RELAYS, ELECTROMAGNETIC, ESTABLISHED RELIABILITY, 4PDT, LOW LEVEL TO 5 AMPERES, PERMANENT
More informationLiquid-Filled Transformers
Liquid-Filled Transformers Custom Transformers at Standard Prices NIAGARA TRANSFORMER CORP. Induction Furnace Transformer Cycloconverter Rectifier Duty Transformer Arc Furnace Transformer Full Range of
More informationcq Ftdllf ~ ret ~q ret ~:II crill. Indian Maritime University
cq Ftdllf ~ ret ~q ret ~:II crill. Indian Maritime University (~ ~~OI~~ Iclll, 'iffio mefir I A Central University, Govt. of India) Cfllcl(f)ldl ~ I Kolkata Campus No. IMU-KC/Laboratory Equipmentll7-18
More informationDNVGL-CP-0212 Edition March 2016
CLASS PROGRAMME Type approval DNVGL-CP-0212 Edition March 2016 The electronic pdf version of this document, available free of charge from http://www.dnvgl.com, is the officially binding version. FOREWORD
More informationTECHNICAL SPECIFICATION FOR POWER TRANSFORMER
TECHNICAL SPECIFICATION FOR POWER TRANSFORMER NOTE: Vendor to give their offer in line with this data sheet only. Any deviations/additions/deletions shall be brought out in a separate sheet. A TECHNICAL
More informationRef No : PUR/GT/IMP/VELC-ADITYA/20/ September 19, 2016.
Ref No : PUR/GT/IMP/VELC-ADITYA/20/2016-17. September 19, 2016. M/s. Dear Sir/s, The Director, Indian Institute of Astrophysics, Bangalore, invites Sealed Tenders (both price bid & technical bid) for the
More informationBUREAU OF INDIAN STANDARDS. Draft Indian Standard TWO COMPONENTS HIGH BUILD EPOXY MICACIOUS IRON OXIDE (MIO) PIGMENTED INTERMEDIATE COAT SPECIFICATION
FOR BIS USE ONLY DOC:CHD 20 (1932)C December 2012 BUREAU OF INDIAN STANDARDS Draft Indian Standard TWO COMPONENTS HIGH BUILD EPOXY MICACIOUS IRON OXIDE (MIO) PIGMENTED INTERMEDIATE COAT SPECIFICATION (Not
More informationSTANDARD SPECIFICATION FOR COLD JUNCTION COMPENSATION BOXES (CJCB)
SHEET 1 of 5 STANDARD SPECIFICATION FOR COLD JUNCTION COMPENSATION BOXES (CJCB) SPECIFICATION NO.: PES- 145-072 BHARAT HEAVY ELECTRICALS LIMITED POWER SECTOR PROJECTS ENGINEERING MANAGEMENT NOIDA INDIA
More informationMISSISSIPPI STATE UNIVERSITY Office of Planning Design and Construction Administration
SECTION 01 340 - SHOP DRAWINGS, PRODUCT DATA AND SAMPLES PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and other
More informationHOW TO SAFE GUARD THE TRANSFORMER..???
CPRI HOW TO SAFE GUARD THE TRANSFORMER..??? CPRI Efficient and Effective network planning, Design and Forecasting Highly Reliable and Stable Protection system and co-ordination Measures to mitigate various
More informationPERFORMANCE SPECIFICATION SHEET RELAY, ELECTROMAGNETIC PERMANENT MAGNET DRIVE, 25 AMPERES, SPDT, HERMETICALLY SEALED
INCH-POUND MIL-PRF-6106/19G 18 November 2011 SUPERSEDING MIL-PRF-6106/19F 10 November 2000 PERFORMANCE SPECIFICATION SHEET RELAY, ELECTROMAGNETIC PERMANENT MAGNET DRIVE, 25 AMPERES, SPDT, HERMETICALLY
More informationLIGHTNING ARRESTOR. September 2017 WEST BENGAL STATE ELECTRICITY TRANSMISSION COMPANY LIMITED
LIGHTNING ARRESTOR September 2017 Engineering Department WEST BENGAL STATE ELECTRICITY TRANSMISSION COMPANY LIMITED Regd. Office: VidyutBhawan, Block DJ, SectorII, Bidhannagar, Kolkata 700091. CIN: U40101WB2007SGC113474;
More informationشركة كهرباء محافظة القدس المساهمة المحدودة JERUSALEM DISTRICT ELECTRICITY CO. LTD.
Our Ref.: 14/2018- Date : Messrs: Dear sir, Tender 14/2018 11& 33 KV Lightning Arrestors. You are kindly requested to quote for the supply and delivery to our stores in Shufat Jerusalem, (DDP) of the following
More informationPROTECT 8 INDUSTRIAL UPS. Protect 8.31 Single Phase output 10 kva 80 kva. Protect 8.33 Three Phase output 10 kva 120 kva. Engineering is our business
PROTECT 8 INDUSTRIAL UPS Protect 8.31 Single Phase output 10 kva 80 kva Protect 8.33 Three Phase output 10 kva 120 kva 400 VAC input 216 VDC link 384 VDC link Engineering is our business UPS systems from
More informationNEVADA DEPARTMENT OF TRANSPORTATION Addendum 3 to RFP July 28, 2017
NEVADA DEPARTMENT OF TRANSPORTATION Addendum 3 to RFP 697-16-016 July 28, 2017 Reference is made to the Request for Proposal (RFP) to Service Providers for Nevada Shared Radio Replacement Project, upon
More informationIDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODEL: MODEL: Multimeter Service Information
IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODEL: 61-340 MODEL: 61-342 Multimeter Service Information The Service Information provides the following information: Precautions and safety information Specifications
More informationLAUREL ELECTRONICS, INC.
LAUREL ELECTRONICS, INC. Laureate True RMS AC Voltage & Current Meter with 1 Cycle Update at 50/60 Hz Features True AC or AC plus DC RMS measurement with crest factor of 3.0 at FS Fast response: reading
More informationLICENSING GUIDELINES AND PROCEDURES FOR SHORT-RANGE RADIO SERVICE (SRRS). For the purpose of this Circular, the following terms are defined hereunder:
MEMORANDUM CIRCULAR NO. 01-01-98 SUBJECT: LICENSING GUIDELINES AND PROCEDURES FOR SHORT-RANGE RADIO SERVICE (SRRS). Pursuant to the provisions of Republic Act No.7925 Act No. 3846 as amended, Executive
More informationThree Phase & Single Phase Servo Controlled Voltage Stabilizers
Three Phase & Single Phase Servo Controlled Voltage Stabilizers All components sourced from reputed manufacturers, with confirmation to International standards as minimum prerequisite. 100% raw material
More informationTable of Contents. Introduction... 1
Table of Contents Introduction... 1 1 Connection Impact Assessment Initial Review... 2 1.1 Facility Design Overview... 2 1.1.1 Single Line Diagram ( SLD )... 2 1.1.2 Point of Disconnection - Safety...
More informationSECTION SUBMITTAL PROCEDURES PART 1 - GENERAL 1.1 RELATED DOCUMENTS
SECTION 01 33 00 - SUBMITTAL PROCEDURES PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and other Division 01 Specification
More informationFCL VOLTAGE & FREQUENCY CONVERTERS. FCL H SERIES - SINGLE PHASE - 2 to 30 kva H SERIES MODELS. AC SINGLE PHASE 2 TO 30 kva STATIC VARIABLE AC
STATIC VARIABLE AC VOLTAGE & FREQUENCY CONVERTERS AC SINGLE PHASE 2 TO 30 kva IGBT SOLID STATE PWM DESIGN MODELS INPUT: 22-23 - 24 - OUTPUT: - 40 70Hz FCL 22 / 23 / 24-2 WIRE SINGLE PHASE THE UNIVERSAL
More informationTABLE OF CONTENT
Page : 1 of 34 Project Engineering Standard www.klmtechgroup.com KLM Technology #03-12 Block Aronia, Jalan Sri Perkasa 2 Taman Tampoi Utama 81200 Johor Bahru Malaysia TABLE OF CONTENT SCOPE 3 REFERENCES
More informationMGVCL/MM/ /2082/11KV AB CABLE TECHNICAL SPECIFICATION FOR 11KV AERIAL BUNCHED CABLES FOR OVERHEAD LINES
TECHNICAL SPECIFICATION FOR 11KV AERIAL BUNCHED CABLES FOR OVERHEAD LINES 1. Qualifying Requirement of AB Cable Manufacture/Supplier The manufacturer should have manufactured, successfully type tested
More informationPakistan International Airlines Procurement Logistics Department Commercial Purchases Section Tel: , Fax:
Pakistan International Airlines Procurement Logistics Department Commercial Purchases Section Tel: 99043304, Fax: 34570120 E-mail: dgmpc@piac.aero REF: 18010127 Tender Cost: PKR 6,000 INVITATION TO TENDERS
More informationOn-load tap-changer VACUTAP VRD, VRF, VRG
www.reinhausen.com On-load tap-changer VACUTAP VRD, VRF, VRG Technical Data TD 237/02 Table of Contents Table of Contents 1 General / Technical data... 3 1.1 On-load tap-changer designations... 3 1.2 Summary
More informationTECHNICAL REQUIREMENTS FOR ELECTROMAGNETIC DISTURBANCES EMITTED FROM LIGHTING EQUIPMENT INSTALLED IN TELECOMMUNICATION CENTERS
TR550004 TECHNICAL REQUIREMENTS FOR ELECTROMAGNETIC DISTURBANCES EMITTED FROM LIGHTING EQUIPMENT INSTALLED IN TELECOMMUNICATION CENTERS TR NO. 174001 EDITION 2.1 September 3 rd, 2018 Nippon Telegraph and
More informationAssessment of Certification Activities for Cross Frontier Accreditation
IAF MD 12:2013 IAF Mandatory Document International Accreditation Forum, Inc. Assessment of Certification Activities for Cross Frontier Accreditation IAF MD 12: 2013 IAF MD 12:2013 International Accreditation
More informationCONDITIONS FOR A TENTATIVE APROVAL FOR CONNECTION OF TRANSFORMERS
CONDITIONS FOR A TENTATIVE APROVAL FOR CONNECTION OF TRANSFORMERS Management has tentatively approved your request subject to the following conditions: 1. All distribution materials/equipment must be purchased
More informationSouth African Distribution Code
South African Distribution Code Metering Code Version 6.0 July 2014 This document is approved by the National Energy Regulator of South Africa (NERSA) Issued by: RSA Grid Code Secretariat Contact: Mr.
More informationTRANSMITTER MODEL: KAS-2030M
Page 1 of 16 FCC PART 15, SUBPART B and C TEST REPORT for TRANSMITTER MODEL: KAS-2030M Prepared for WILDLIFE TECHNOLOGIES 115 WOLCOTT STREET MANCHESTER, NEW HAMPSHIRE 03103 Prepared by: KYLE FUJIMOTO Approved
More informationS. C. Electric Cooperative s Specification for a Single-Phase, Single Bushing Overhead Distribution Transformer (Revised 10/2013)
S. C. Electric Cooperative s Specification for a Single-Phase, Single Bushing Overhead Distribution Transformer (Revised 10/2013) 1.0 GENERAL 1.1 This specification covers the electrical and mechanical
More informationTECHNICAL SPECIFICATION FOR LEVEL CONTROL VALVE HANDLING WATER
ANNEXURE-C TO TENDER BAP/FGD/2012/OT-1 BONGAIGAON 3X250 MW FLUE GAS DESULFURIZATION SYSTEM TECHNICAL SPECIFICATION LEVEL CONTROL VALVE HANDLING WATER CUSTOMER : NATIONAL THERMAL POWER CORPORATION LIMITED
More informationATI Evaluation Service A Division of Architectural Testing Certification Services Code Compliance Research Report
ATI Evaluation Service A Division of Architectural Testing Certification Services Subject to Renewal: 04/15/2016 Issued: 06/24/2014 Visit www.ati-es.com for current Revised: 09/24/2014 Page 1 of 21 Maine
More informationSingle Phase. Rating : As Specified. Input Voltage Range : As Specified (Eg. 170V-270 V) Input Supply Frequency : 45Hz-55Hz
Frequent fluctuations or variations of power not only causes financial but manpower loss too! SERVO CONTROLLED VOLTAGE STABILIZERS beast these happenings and provides all extra care needed to your valuable
More informationDNVGL-CP-0293 Edition July 2018
CLASS PROGRAMME Type approval DNVGL-CP-0293 Edition July 2018 The content of this service document is the subject of intellectual property rights reserved by ("DNV GL"). The user accepts that it is prohibited
More information