INSTRUCTIONS INTRODUCTION

Size: px
Start display at page:

Download "INSTRUCTIONS INTRODUCTION"

Transcription

1 Westinghouse. L NSTALLATON OPERATON MANTENANCE NSTRUCTONS TYPES HKB/TCU - SKB/TCU & SKBU RELAYS NTRODUCTON This instruction leaflet describes the overall functioning of HKB/TCU, SKB/TCU and SKBU relays when used in conjunction with a TC power line carrier channel. Detailed description of operation, as well as setting and maintenance recommendations for the individual relays for the phase comparison system are covered in the individual relay instruction leaflets; intended to supplement these relay instructions. Unless other1vise stated, the HKB/TCU, the description here is the following sections of this leaflet apply to all SKB/TCU and SKBU relaying systems. APPLCATON Phase comparison carrier relaying is a well established system for the high speed protection of power transmission lines. The type HKB, SKB and SKBU relay are the high speed carrier relays used in conjunction with power line carrier equipment to provide complete phase and ground fault protection of a transmission line section. The basic concept of these schemes are the same as differential relaying. These relays operate on line current only, and no source of ac line potential is required. Consequently, it will not trip during a system swing or out-of-step conditions. For normal application for two-terminal lines, the fault detector settings are determined from a comparison of the maximum load and minimum fault currents. With the required 1.25 ratio between FD-2 and FD-1 pickup, can usually be obtained. reasonaole settings For three-terminal lines which approximately have equal currents fed in two-terminals and the current sum flows out the third terminal of the line, used. the ratio of 2.5 oetween FD-2 and FD-1 pickup should be Since these relaying systems operate only during a fault, the carrier channels are available at all other times for the transmission of other functions. EQUPMENT COMPLEMENT The equipment complement of these relaying systems are listed in Table. The functions of each unit are: NEW NFORMATON EFFECTVE MARCH 1968

2 interuptions in carrier caused by arcing over of protective gaps in the tuning equipment. The unction of the squelch circuit is to hold off the carrier for a period of 150 ms after the breaker "a" contact opens. This is to prevent undesirable carrier blocking of another terminal which might be somewhat slower in tripping because of a lower value of fault current or of some other reasons at that terminal. External Fault During an external fault, when the fault detectors pickup. Carrier is transmitted from the two ends of the line on alternate half cycles. This occurs because the current at one end of the line has reversed with respect to the current for an internal fault. n this case, the local (or remote 0 if current reversed at the remote end) squaring amplifier will be shifted 180, in Fig. 5, as shown i.e. the input from the remote squaring amplifier of the comparer AND will have a blocking signal while the local squaring amplifier output has a tripping signal. As a result there will be no tripping signal output from the comparer and tripping will be blocked. Transient Blocking Since the sequence filter and the low pass filter contain reactive circuit elements, discharge of their stored energy after the clearing of an external fault might cause an incorrect relay operation or a false tripping may result during a sudden reversal in the direction of fault power flow in the protected line, due to the sequential clearing of a fault on a parallel line. n order to improve the security of this relaying system against such conditions, transient blocking circuit has been added. For any fault, operates, if tripping does not occur in less than 2 cycles after FD-2 the Flip-Flop will be desensitized so that a transient pulse cannot operate it. However, if an internal fault developes before the external fault is cleared, the change in phase position of the local and remote carrier pulses will cancel the transient blocking after approximately 2 cycles to allow a slightly delayed tripping. SYSTEM FUNCTONAL TEST PROVSONS t is desirable to check periodically the condition of the carrier set to determine its ability to send and receive a carrier signal. a test switch 85/PB is connected to the carrier start elements. a For this purpose Pressing the test pushbutton sends a carrier signal which is received by the remote receiver to operate an alarm relay TT-l and energize a milliammeter. set is not functioning properly, does not deflect, f the carrier the alarm is not heard and the milliammeter indicating trouble which must be investigated and corrected. Operation of these relaying systems for all faults are dependent upon correct functioning of the carrier equipment components as l rell as the HK8, SKB or SKBU relay itself. The test facilities which including a type W2 switch and a special testing transformer provide a simple manually operated test procedure for these systems that will check the combined relay and carrier equipment. Detailed test procedure is described in.lr and , for the HKB/TCU, SKB(TCU, and SKBU phase comparison relaying systems respectively. -4-

3 " T T TERMNALS.(408C367) lr OF TC OR TCU SET. 8U/TC Phase Comparison Relaying System. TRP CRCUT -6- " 18,., 8-P! 85-RS 85-TR 8 -TS POSTON CON PUL PUSH T2 T1 OFF '. L AB AB 12 CARR 11: RELAYNG AB AB 5 AB 6... AB 7 TfST t """'\ ron CD,..,. CD 12 CD 0 CD 5 ) CD 6 to 1 EF EF EF EF 5 EF 6 NTE::NAL EF 7 TT-l RELAY SCHEMATC i88a123 TYPE Ht(8 RELAY 88A291 Ji:\1n:ST ltuhuttom -- RESERVE SiGNAL TEST!29C703 TEST RDf[T 'USH8UTTetf - CARRER TEST SWTCH(W21 -- rt[st SWTCH S UPf>LEO WTH] ASSU18LED COMlCTCMS THUS ETERNAL CONNTONS NEED ONLY H: MADE AT DESGNATED - TERMNAL E' 85 TS ""F- WESTNGHOUSE MAD N U.S.A

4 TRPPNG Olii[CTON... U' o- LNE TRAP " ',. " 0, '1 ',,..... " " c 2,. 5 CARRER TEST SWTCH 1/TS afbu df1 T2 Tl f5[5 F6 6 2,..., i 2 SKBU SEQ NETVQK i: TEST TRANSFORMER fl V 60 CYC ( 1..,JfASE WTH REMOTE END) H LOW-PAS FLTER PHAS!: " SPLTT!:" TUNER :t! FD-2 ' -- ''o--l!:::;.. --n.. CARR Ti T...:,-: T,' Lf TS... fi!""' COUAL CABLE TO CAUtl[lt CANET lll " l ri....,. r 3 reyng Jl CRCUT t!--j '' g!; ' i U snunch +45V S,:;; WTR i kl.-:r. "'' l F )"'3" -!----- NORMAL L----+-,-- ONDUCTED jl>t!l;> c!>--.., Rl...,.PN CONNECTOR OF SKBU Fig. 2 External Connection of SKBU/T j

5 120V 60"-' TEST SOURCE {N PHASE WTH RUlOTE ENOl Fig. 1 COA TO TYPETC CARRER SET TRANSFORMER {SEC) SHELDED TW STED PAR (SHELD GROUNDED} l o CARRER CABN!.,.PN CONNECT External Connection of HKB/T

6 c-} CARRER LL RECEVED ALARM C Phase Comparison Relaying System. BkR NO 2 TRP CRCUT POS-G- -8- DE\/ NO DEVCE 74 TT-l RE LAY 1848 AA41 78 SKBU RELAY 17& : B51 rs TYPE W2 TEST SWTCH TC TR-1 RE AY TC CARRER SET 3R A 99. L B<R' NO TRP CRCOlT POS " ' T '" ,..... Tit CARR[R 0" TEST TEST 2 0 ON ( ON 'vi[w 9 H ' CS " Yi... as,rs TYPE W> CARR RlillSWJCJ, POSTON TE T CONTA f ()1j HANoLE OUT HANO.[ OUT.. N,. A5-8" A6-B6 A7-8, Cl Dl - K - G -H G7-7 : DENOTES CONTACT CLOSED 5476Dl7 --

7 A L Fig. 4 NTERNAL FAULT A B (\[\[V f---i 1---f J---1 -alock J l-..j 1--J -- -TRP '-- local and remote squaring ampllfien have tripping output during them lnle,...lt when ca"le< 1101 tra...,..ltted. 87 HKB, SKB,S<BU 17 TCU + 87 AND 87 ARE N A SAME PACKAGE FOR S<BU. 87 AA D1.] TRP N N ELAY d 1 t;( : g: L 1 j HKB/TCU/TC SYSTEM ONLY j 863A193 Block Diagram of Phase Comparison Relaying Logic. -LOCK -TliiP Fig. 5 LOCAL SEQUENCE NETWORK OUTPUT LOCAL SQUARNG AMPliFER OU11'J1' local CARRER REMOTE CARRER REMOTE SQUARNG AMPLFER 01J11'111' TRPPNG PULSES Phase Comparison Transmitter Keying ETERNAL FAULT A B NONE NoM that remote squaring amplifier oul has contlnuaus blocling polarity o external fault, since t responds to i the local and,.,..,.. co"*' sig'

8 ST 0 PAR toundfd) l8c423) T CR7 T U: PHONE JACkS ON $W TCHOAftO,(FRONT VEW! Jl AT RGHT J2AT LEFT) Phase Comparison Relaying System. TRP CRCUT POS,tr- res± CS CS.Ut 78 TO -10- BACK UP RELAY DEVCE NO. 74,.,., 15-P 85-RS &-Tit 85-TS. L TS W2 CARR. TEST SW ONT AB POSTON ol pnsh Tl Tl f""i"" ON... AB'l AB NAMEPLATE AB 5 AB 6 AB7 o.. CD n:st \ ro CD2 TE:ST2-=-0 :::- CD co 5 CD 6.J \ 0 7 EF ff12 EF EF EF 6 EF 7 HHUNAL CH:rolTC W STNGHOUR MAD( 1ft U.S A. TVPl TT-l RELAY lha 323 fyh SQ MlAY TCU S(T CAtlti.R TU'T ltus...,tton RESU' ltcttal TUT lltc701 TilT ltt: T 'USHeUTTON CARRDt T!:ST SWTCH (W2) J ltest SWTCH S SUPPU 0 WTiol ASSfML[D CONN!TOS THUS ETERNAl CONNECTfOM 1ED ONLY E W.OE AT DSGNAT!O Tf ltiiin.a.. fl : U:.ll Fl 5476Dl6

9 TRPPNG DRECTON TEST TRANifOtM[t "-' TEST SOURCE (N PHASE WTH REMOTE END) -9- Fig. 3 COA TO TYPE TC CARRER SET r CARRER SKB SAT TRA 1- SEC WNDN CAE ---.>-PN CONNECTO External Connections of SKB

10 . L lfestnghouse ELECTRC CORPORATON ELAY-NSTRUMENT DVSON NEWARK, N. J. Printed in U.S.A.

www. ElectricalPartManuals. com 61. -;. " ' ' t - " Type MTR Static Overcurrent Protection Package ... Westinghouse Electric Corporation

www. ElectricalPartManuals. com 61. -;.  ' ' t -  Type MTR Static Overcurrent Protection Package ... Westinghouse Electric Corporation ... December 1976 New nformation E,D,C/1994/DB Westinghouse Electric Corporation Distribution Apparatus Division Bloomington, ndiana 47401 Static Control for All Reclosers '" 38-724 Page 1 Type MTR Static

More information

System Protection and Control Seminar

System Protection and Control Seminar System Protection and Control Seminar Desirable Protection We want to detect a fault within 100% of the zone of protection. We want to avoid interrupting non-faulted zones of protection. We want to clear

More information

Electrical Systems - Course 135 COMPOSITE ELECTRICAL PROTECTIVE SCHEMES: PART I

Electrical Systems - Course 135 COMPOSITE ELECTRICAL PROTECTIVE SCHEMES: PART I Electrical Systems - Course 135 COMPOSTE ELECTRCAL PROTECTVE SCHEMES: PART BUSES AND TRANSFORMERS L.0 ntroducton Following on from lesson 135.03-1, this lesson shows componte protective schemes for buses

More information

~'----MA_N_UAL_5_ J~

~'----MA_N_UAL_5_ J~ WABCC '----MA_N_UAL_5_43 -...J STYLE FST FREQUENCY SHFT CARRER EQUPMENT CONTENTS Section No. Title Page V NTRODUCTON. 1. 1 Purpose DESCRPTON AND OPERATON. 2. 1 General.... 2. 2 Application.... 2. 3 Circuit

More information

Transmission Lines and Feeders Protection Pilot wire differential relays (Device 87L) Distance protection

Transmission Lines and Feeders Protection Pilot wire differential relays (Device 87L) Distance protection Transmission Lines and Feeders Protection Pilot wire differential relays (Device 87L) Distance protection 133 1. Pilot wire differential relays (Device 87L) The pilot wire differential relay is a high-speed

More information

CODED CARRIER CONTROL SYSTEM

CODED CARRIER CONTROL SYSTEM T DESCRPTON OF i CODED CARRER CONTROL SYSTEM. FOR USE WTH TME CODE CONTROL SYSTEMS MANUAL No. 507... Revised and Reprinted MARCH, 1947 UNON SWTCH & SGNAL CO. SWSSVALE PENNSYLVANA 2.5M-3-47-2 T COPYRGHT,

More information

DATA SET 109B TYPE DESCRIPTION

DATA SET 109B TYPE DESCRIPTION BELL SYSTEM Plant Series PRACTCES SECTON 312-802-100 ssue 1, December 1967 AT&TCo Swdard DATA SET 109B TYPE DESCRPTON 1. GENERAL 1.01 This section describes Data Set 109B type (109B1 and 109B2) physically

More information

Relay Communication Misoperations. Southwest Power Pool System Protection and Control Working Group

Relay Communication Misoperations. Southwest Power Pool System Protection and Control Working Group Relay Communication Misoperations Southwest Power Pool System Protection and Control Working Group Relay Misoperations The fundamental objective of power system protection schemes is to quickly provide

More information

www. ElectricalPartManuals. com Westinghouse HRU Instantaneous Overcurrent Relay with Harmonic Restraint Descriptive Bulletin Page 1

www. ElectricalPartManuals. com Westinghouse HRU Instantaneous Overcurrent Relay with Harmonic Restraint Descriptive Bulletin Page 1 Westinghouse Appl ication The H R U harmonic restraint relay is a high speed relay used for the supervision of differential, overcurrent. or pilot relays. It is applied in various transformer protection

More information

TC 10B FREQUENCY-PROGRAMMABLE ON/OFF CARRIER TRANSMITTER/RECEIVER. System Manual. Technologies, Inc. CC44 VER04

TC 10B FREQUENCY-PROGRAMMABLE ON/OFF CARRIER TRANSMITTER/RECEIVER. System Manual. Technologies, Inc. CC44 VER04 TC 10B FREQUENCY-PROGRAMMABLE ON/OFF CARRIER TRANSMITTER/RECEIVER System Manual CC44 VER04 (Replaces CC44 VER03) Technologies, Inc. 4050 N.W. 121st Avenue Coral Springs, FL U.S.A. 33065 1 800 785 7274

More information

PROTECTION SIGNALLING

PROTECTION SIGNALLING PROTECTION SIGNALLING 1 Directional Comparison Distance Protection Schemes The importance of transmission system integrity necessitates high-speed fault clearing times and highspeed auto reclosing to avoid

More information

* * * * * * * * * INSTALLATION AND MAINTENANCE

* * * * * * * * * INSTALLATION AND MAINTENANCE .-- )., TYPE CCRP RECTFERS * * * * * * * * * NSTALLATON AND MANTENANCE SERVCE MANUAL 595 CONTENTS Page... V. v. V. TABLE... V. NTRODUCTON..... DESCRPTON. OPERATON... A. NPUT VOLTAGE... B. CHARGNG BATTERES..

More information

INTERCONNECTING DEVICES COMMON EQUIPMENT 75A CONTROL UNIT

INTERCONNECTING DEVICES COMMON EQUIPMENT 75A CONTROL UNIT BSP 463-300-112-i01_1973-11.01.jpg Scanned by Frank Harrell (CowboyFrank) Castle Rock. Colorado Feb 23.2016 21:15:56 BELL SYSTEM PRACTCES AT&TCo Standard SECTON 463-300-112 ssue 1, November 1973 NTERCONNECTNG

More information

Phase Comparison Relaying

Phase Comparison Relaying MULTILIN GER-2681B GE Power Management Phase Comparison Relaying PHASE COMPARISON RELAYING INTRODUCTION Phase comparison relaying is a kind of differential relaying that compares the phase angles of the

More information

MATRIX BLOCK-1 A 1 IDENTIFICATION, INSTALLATION, WIRING, AND MAINTENANCE I

MATRIX BLOCK-1 A 1 IDENTIFICATION, INSTALLATION, WIRING, AND MAINTENANCE I ELL SYSTEM PRACTCES AT&TCo Stondord ssue 2, December 1971 MATRX LOCK-1 A 1 DENTFCATON, NSTALLATON, WRNG, AND MANTENANCE 1. GENERAL 1.01 This section provides identification, installation, wiring and maintenance

More information

150-BAUD PRIVATE LINE CHANNELS

150-BAUD PRIVATE LINE CHANNELS BELL SYSTEM Plant Series PRACTCES SECTON 32-0-0 ssue, JUY 970 AT&TCo Standard 50-BAUD PRVATE LNE CHANNELS NTERFACE SPECFCATONS. DESCRPTON GENERAL.0 The purpose of this specification is to define the interface

More information

www. ElectricalPartManuals. com Basler Electric P. 0. BOX 269 HIGHLAND, ILLINOIS 62249, U.S.A. PHONE FAX

www. ElectricalPartManuals. com Basler Electric P. 0. BOX 269 HIGHLAND, ILLINOIS 62249, U.S.A. PHONE FAX The BE1-47N Voltage Phase Sequence Relay provides protection for rotating equipment from the damaging effects of excessive negative sequence voltage resulting from phase failure, phase unbalance and reversed

More information

c. Battery Charger c Volt Supply TL MICROWAVE RADIO DESCRIPTION POWER SUPPLY H. Battery Voltage Alarm Circuit.

c. Battery Charger c Volt Supply TL MICROWAVE RADIO DESCRIPTION POWER SUPPLY H. Battery Voltage Alarm Circuit. BELL SYSTEM PRACTCES Plant Series 2. OPERATNG PRNCPLES CONTENTS PAGE B. Klystron Supply Regulator and nverter. D. Battery Voltage Alarm Circuit. 3. CRCUT DESCRPTON. A. Klystron Supply Regulator and nverter.

More information

www. ElectricalPartManuals. com Basler Electric -.. BE1-810/U DIGITAL FREQUENCY RELAY ADDITIONAL INFORMATION INSTRUCTION MANUAL

www. ElectricalPartManuals. com Basler Electric -.. BE1-810/U DIGITAL FREQUENCY RELAY ADDITIONAL INFORMATION INSTRUCTION MANUAL ...... The BE181 0/U Digital Frequency Relay senses an ac voltage: from a power system or generator to provide protection in the event that the frequency exceeds predetermined limits. Reliable solidstate

More information

STYLE F-40A DC/DC CONVERTER MAINTENANCE INSTRUCTIONS Suitable for Outdoor Mounting) * * * * * * * * * * * (N )

STYLE F-40A DC/DC CONVERTER MAINTENANCE INSTRUCTIONS Suitable for Outdoor Mounting) * * * * * * * * * * * (N ) An American-Standard Company.. SERVCE MANUAL 5799 (Not STYLE F-40A DC/DC CONVERTER MANTENANCE NSTRUCTONS Suitable for Outdoor Mounting) * * * * * * * * * * * (N451033-0801) Description The Style F-40A

More information

ABB Automation, Inc. Substation Automation & Protection Division Coral Springs, FL Allentown, PA

ABB Automation, Inc. Substation Automation & Protection Division Coral Springs, FL Allentown, PA ABB Automation, Inc. Substation Automation & Protection Division Coral Springs, FL Allentown, PA Instruction Leaflet 41-348.1H Effective: November 1997 Supersedes I.L. I.L. 41-348.1G, Dated January 1985

More information

www. ElectricalPartManuals. com INSTRUCTIONS Westinghouse I.L. 41-S01.2C TYPE CF-1 UNDER AND OVER FREQUENCY RELAY INSTALLATION OPERATION MAINTENANCE

www. ElectricalPartManuals. com INSTRUCTIONS Westinghouse I.L. 41-S01.2C TYPE CF-1 UNDER AND OVER FREQUENCY RELAY INSTALLATION OPERATION MAINTENANCE Westinghouse.L. 1-S1.C NSTALLATON OPERATON MANTENANCE NSTRUCTONS TYPE CF-1 UNDER AND OVER FREQUENCY RELAY CAUTON Before putting relays into service, remove all blocking hich may have been inserted for

More information

To learn fundamentals of high speed I/O link equalization techniques.

To learn fundamentals of high speed I/O link equalization techniques. 1 ECEN 720 High-Speed Links: Circuits and Systems Lab5 Equalization Circuits Objective To learn fundamentals of high speed I/O link equalization techniques. Introduction An ideal cable could propagate

More information

6CARRIER-CURRENT-PILOT AND MICROWAVE-PILOT RELAYS

6CARRIER-CURRENT-PILOT AND MICROWAVE-PILOT RELAYS 6CARRIER-CURRENT-PILOT AND MICROWAVE-PILOT RELAYS Chapter 5 introduced the subject of pilot relaying, gave the fundamental principles involved, and described some typical wire-pilot relaying equipments.

More information

INSTRUCTIONS. TYPE SA-l GENERATOR DIFFERENTIAL RELAY

INSTRUCTIONS. TYPE SA-l GENERATOR DIFFERENTIAL RELAY CAUTON: Westinghouse 1. L. 41348. 1c NSTALLATON OPERATON MANTENANCE NSTRUCTONS TYPE SAl GENERATOR DFFERENTAL RELAY Before putting relays into Bervice, operate the relay to check the electrical connections.

More information

INSTRUCTIONS. voltage controls the firing of. The d-e voltage is

INSTRUCTIONS. voltage controls the firing of. The d-e voltage is NSTALLATON OPERATON. L. 41811 MANTENANCE NSTRUCTONS ELECTRONC TELEMETERNG RECEVER TYPE R2 CAUTON Before putting receivers into service, remove all blocking which may have been inserted for the purpose

More information

ABB Power T&D Company Inc. Relay Division Coral Springs, FL Allentown, PA

ABB Power T&D Company Inc. Relay Division Coral Springs, FL Allentown, PA Jlllll,.'1.1. September, 1990 Supersedes 41971, pages 1 4, dated August, 1989 Mailed to: E, D, C41100A, 41900A ABB Power T&D Company Inc. Relay Division Coral Springs, FL Allentown, PA For Phase and Ground

More information

INSTRUCTION PAMPHLET U-5743

INSTRUCTION PAMPHLET U-5743 WABCC I! I,. INSTRUCTION PAMPHLET U-5743 INSTALLATION AND MAINTENANCE INSTRUCTIONS FOR UNION TRANSISTORIZED UNIT CARRIER INTRODUCTION The Union Transistorized Unit Carrier equipment is a keyed frequency

More information

Model FLSC-C1-LIQ. Microprocessor Based Loop Powered Transmitter

Model FLSC-C1-LIQ. Microprocessor Based Loop Powered Transmitter Model FLSC-C1-LIQ Microprocessor Based Loop Powered Transmitter CONTENTS 1. Introduction ------------------------------------------------------------ 2 2. Specifications-----------------------------------------------------------

More information

NAVAL TACTICAL DATA SYSTEM (NTDS) INPUT / OUTPUT SPECIFICATION - AN/USQ-20 COMPUTER SET. technical note no OF S,ElIY land coapoiation

NAVAL TACTICAL DATA SYSTEM (NTDS) INPUT / OUTPUT SPECIFICATION - AN/USQ-20 COMPUTER SET. technical note no OF S,ElIY land coapoiation NAVAL TACTCAL DATA SYSTEM (NTDS) technical note no. 2 21 NPUT / OUTPUT SPECFCATON - AN/USQ-20 COMPUTER SET DVSON OF S,ElY land coapoaton UNVAC 'ARt, $to.au\. '., "'"""OtA NA V Al TACTCAL DATA SYSTEM TECHNCAL

More information

Type KLF Generator Field Protection-Loss of Field Relay

Type KLF Generator Field Protection-Loss of Field Relay Supersedes DB 41-745B pages 1-4, dated June, 1989 Mailed to: E, D, C/41-700A ABB Power T&D Company Inc. Relay Division Coral Springs, FL Allentown, PA For Use With Delta Connected Potential Transformers

More information

Protection Basics Presented by John S. Levine, P.E. Levine Lectronics and Lectric, Inc GE Consumer & Industrial Multilin

Protection Basics Presented by John S. Levine, P.E. Levine Lectronics and Lectric, Inc GE Consumer & Industrial Multilin Protection Basics Presented by John S. Levine, P.E. Levine Lectronics and Lectric, Inc. 770 565-1556 John@L-3.com 1 Protection Fundamentals By John Levine 2 Introductions Tools Outline Enervista Launchpad

More information

Central Station Timer and Command Decoder Interface

Central Station Timer and Command Decoder Interface Central Station Timer and Command Decoder nterface NO. ATM-76 ftage REV. NO.c 0, DATE 5/28/68 This unscheduled ATM is published to define the switching operation of the Central Station Timer and its interface

More information

Height: inches Width: inches Depth: inches, inches. Listings/Certification UL 1053 ANSI C37-90 IEC 255. General Description

Height: inches Width: inches Depth: inches, inches. Listings/Certification UL 1053 ANSI C37-90 IEC 255. General Description 1rcJll Cutler-Hammer New nformation Applications Provides reliable 3-phase and ground overcurrent protection for all voltage levels. Primary feeder circuit protection Primary transformer protection Backup

More information

NO WARRANTIES OF ANY KIND ARE IMPLIED ON THE INFORMATION CONTAINED IN THIS DOCUMENT.

NO WARRANTIES OF ANY KIND ARE IMPLIED ON THE INFORMATION CONTAINED IN THIS DOCUMENT. MODBUS/BECO2200-M3425A Communication Data Base for M-3425A Integrated Protection System Device I.D. = 150 Specifications presented herein are thought to be accurate at the time of publication but are subject

More information

Digital Line Protection System

Digital Line Protection System Digital Line Protection System! Microprocessor Based Protection, Control and Monitoring System! Waveform Sampling! Proven Protection! Economical! Ease of Retrofit 1 DLP-D D Enhancements ASCII SUBSET Three

More information

Transmission Line Protection Objective. General knowledge and familiarity with transmission protection schemes

Transmission Line Protection Objective. General knowledge and familiarity with transmission protection schemes Transmission Line Protection Objective General knowledge and familiarity with transmission protection schemes Transmission Line Protection Topics Primary/backup protection Coordination Communication-based

More information

www. ElectricalPartManuals. com Type CGR Ratio Ground Relay Descriptive Bulletin Page 1

www. ElectricalPartManuals. com Type CGR Ratio Ground Relay Descriptive Bulletin Page 1 November, 1981 New nformation Mailed to: E,D,C/211, 219/DB Westinghouse Electric Corporation Relay-nstrument Division Coral Springs, FL 65 Page 1 Type CGR Ratio Ground Relay "" Page 2 Application Three

More information

MAINTENANCE MANUAL 1B170K17 FOUR SHOT AUTO RECLOSE RELAY

MAINTENANCE MANUAL 1B170K17 FOUR SHOT AUTO RECLOSE RELAY Sheet 1 of 9 MAINTENANCE MANUAL 1B170K17 FOUR SHOT AUTO RECLOSE RELAY The Maintenance Manual is to be read in conunction with Product/Test Manual Sheet 2 of 9 INDEX 1. FULL DESCRIPTION OF OPERATION 1.1

More information

Power Plant and Transmission System Protection Coordination Fundamentals

Power Plant and Transmission System Protection Coordination Fundamentals Power Plant and Transmission System Protection Coordination Fundamentals NERC Protection Coordination Webinar Series June 2, 2010 Jon Gardell Agenda 2 Objective Introduction to Protection Generator and

More information

DST-2000C. Direction Sensing Tachometer INSTRUCTION MANUAL

DST-2000C. Direction Sensing Tachometer INSTRUCTION MANUAL DST-2000C Direction Sensing Tachometer INSTRUCTION MANUAL Azonix-Dynalco, 3690 N. W. 53 Street, Ft. Lauderdale, FL 33309 U.S.A.! (954) 739-4300 Fax (954) 484-3376 www.dynalco.com mailbox@dynalco.com October

More information

OVEN INDUSTRIES, INC. Model 5C7-362

OVEN INDUSTRIES, INC. Model 5C7-362 OVEN INDUSTRIES, INC. OPERATING MANUAL Model 5C7-362 THERMOELECTRIC MODULE TEMPERATURE CONTROLLER TABLE OF CONTENTS Features... 1 Description... 2 Block Diagram... 3 RS232 Communications Connections...

More information

www. ElectricalPartManuals. com INSTRUCTIONS TYPE IM RECEIVER FOR HIGH RATE IMPULSE TELEMETEl{N APPLICATION CONSTRUCTION AND OPERATION

www. ElectricalPartManuals. com INSTRUCTIONS TYPE IM RECEIVER FOR HIGH RATE IMPULSE TELEMETEl{N APPLICATION CONSTRUCTION AND OPERATION j. )..L. 41-825.2 A NSTALLATON OPERATON MANTENANCE NSTRUCTONS TYPE M RECEVER,.. ;Jj' ""'"'"': FOR HGH RATE MPULSE TELEMETEl{N CAUTON Before putting receivers into service, remove all blocking which may

More information

INSTRUCTIONS TYPE SBF STATIC BREAKER FAILURE RELAY

INSTRUCTIONS TYPE SBF STATIC BREAKER FAILURE RELAY Westinghouse I. L. 41-776. 3 INSTALLATION OPERATION MAINTENANCE INSTRUCTIONS TYPE SBF STATIC BREAKER FAILURE RELAY CAUTION: Before putting relay into service, operate the relay to check the electrical

More information

Model 305 Synchronous Countdown System

Model 305 Synchronous Countdown System Model 305 Synchronous Countdown System Introduction: The Model 305 pre-settable countdown electronics is a high-speed synchronous divider that generates an electronic trigger pulse, locked in time with

More information

NERC Protection Coordination Webinar Series July 15, Jon Gardell

NERC Protection Coordination Webinar Series July 15, Jon Gardell Power Plant and Transmission System Protection Coordination Reverse Power (32), Negative Sequence Current (46), Inadvertent Energizing (50/27), Stator Ground Fault (59GN/27TH), Generator Differential (87G),

More information

2015 Relay School Bus Protection Mike Kockott March, 2015

2015 Relay School Bus Protection Mike Kockott March, 2015 2015 Relay School Bus Protection Mike Kockott March, 2015 History of Bus Protection Circulating current differential (1900s) High impedance differential (1940s) Percentage restrained differential (1960s)

More information

FREQUENCY AGILE FM MODULATOR INSTRUCTION BOOK IB

FREQUENCY AGILE FM MODULATOR INSTRUCTION BOOK IB FMT615C FREQUENCY AGILE FM MODULATOR INSTRUCTION BOOK IB1215-02 TABLE OF CONTENTS SECTION SUBJECT 1.0 Introduction 2.0 Installation & Operating Instructions 3.0 Specification 4.0 Functional Description

More information

METALLIC FACILITY TERMINAL LOOP-START AND GROUND-START TO DX OR E&M SIGNALING CONVERTERS (J99343FA, FB, FC, AND FD)

METALLIC FACILITY TERMINAL LOOP-START AND GROUND-START TO DX OR E&M SIGNALING CONVERTERS (J99343FA, FB, FC, AND FD) BELL SYSTEM PRACTCES AT&TCo Standard ssue 1, November 1979 METALLC FACLTY TERMNAL LOOPSTART AND GROUNDSTART TO DX OR E&M SGNALNG CONVERTERS (J99343FA, FB, FC, AND FD) NSTALLATON AND TESTNG,. CONTENTS PAGE

More information

CAR - TEST - SYSTEM 14

CAR - TEST - SYSTEM 14 CAR - TEST - SYSTEM 14 EMC-Test Equipment for electrical installation of vehicles Acc. to ISO 7637-2, ISO 16750-2 ISO 21848 Rise time variable 1-5µs Pulse Waveforms : #1 1-5/2000µs, 600 V, ISO 1-5/1000µs,

More information

BELL SYSTEM PRACTICES Plant Series

BELL SYSTEM PRACTICES Plant Series BELL SYSTEM PRACTCES Plant Series SECTON 58469MS ssue B, August, 963 M. S. T. & T. Co. CON COLLECTOR TELECART dentification, nstallation and Maintenance. DENTFCATON. The Coin Collector Telecart consists

More information

Style FR HI Shunt Track Unit

Style FR HI Shunt Track Unit I UNION SWITCH & SIGNALlimt 645 Russell Street Batesburg, SC 29006 Service Manual 5966 Style FR HI Shunt Track Unit Installation, Operation and Maintenance July, 1980 1980, Union Switch & Signal Inc. Printed

More information

9600 bps, Dual Modem 170 Card Private Wire Only

9600 bps, Dual Modem 170 Card Private Wire Only 896 9600 bps, Dual Modem 170 Card Private Wire Only Users Guide 280 Interstate 80 West Exit 1 / PO Box 1330, Verdi, NV 89439 Phone: 775-345-8000 Fax: 775-345-8010 E-mail: traffic@sgdi.net TABLE OF CONTENTS

More information

Transmission Protection Overview

Transmission Protection Overview Transmission Protection Overview 2017 Hands-On Relay School Daniel Henriod Schweitzer Engineering Laboratories Pullman, WA Transmission Line Protection Objective General knowledge and familiarity with

More information

Model 4xx. Plug-in Series Of FSK Modems USER GUIDE. (TI) 20 Jan 06 DWG: A GDI COMMUNICATIONS LLC PO Box I-80 Exit 1 Verdi, NV 89439

Model 4xx. Plug-in Series Of FSK Modems USER GUIDE. (TI) 20 Jan 06 DWG: A GDI COMMUNICATIONS LLC PO Box I-80 Exit 1 Verdi, NV 89439 Model 4xx Plug-in Series Of FSK s USER GUIDE (TI) 20 Jan 06 DWG: A01164 GDI COMMUNICATIONS LLC PO Box 1330 280 I-80 Exit 1 Verdi, NV 89439 Phone: (775) 345-8000 Fax: (775) 345-8010 Web: www.sgdi.com Email:

More information

A MAGNETIC DEVICE FOR COMPUTER GRAPHIC INPUT

A MAGNETIC DEVICE FOR COMPUTER GRAPHIC INPUT A MAGNETC DEVCE FOR COMPUTER GRAPHC NPUT M. H. Lewin RCA Laboratories, Radio Corporation of America Princeton, New ersey NTRODUCTON Recent work on systems to facilitate the input of graphical information

More information

PSV3St _ Phase-Sequence Voltage Protection Stage1 (PSV3St1) Stage2 (PSV3St2)

PSV3St _ Phase-Sequence Voltage Protection Stage1 (PSV3St1) Stage2 (PSV3St2) 1MRS752324-MUM Issued: 3/2000 Version: D/23.06.2005 Data subject to change without notice PSV3St _ Phase-Sequence Voltage Protection Stage1 (PSV3St1) Stage2 (PSV3St2) Contents 1. Introduction... 2 1.1

More information

SERVICE. 1. GENERAL 661A3 the appropriate key must be separately ordered and installed. For ordering and installing

SERVICE. 1. GENERAL 661A3 the appropriate key must be separately ordered and installed. For ordering and installing BELL SYSTEM Plant Series PRACTCES SECTON 502-67-40 ssue, December 970 AT&TCo Standard SERVCE 66-TYPE TELEPHONE SETS. GENERAL 66A3 the appropriate key must be separately ordered and installed. For ordering

More information

Earth Fault Protection

Earth Fault Protection Earth Fault Protection Course No: E03-038 Credit: 3 PDH Velimir Lackovic, Char. Eng. Continuing Education and Development, Inc. 9 Greyridge Farm Court Stony Point, NY 10980 P: (877) 322-5800 F: (877) 322-4774

More information

Array E System Grounding Philosophy. This ATM briefly describes modifications to system grounding

Array E System Grounding Philosophy. This ATM briefly describes modifications to system grounding Array E System Grounding Philosophy NO. ATM-962 PAGE 1 REV. NO. OF 14 DATE This ATM briefly describes modifications to system grounding philosophy from those applied on previous flights and provides system

More information

RETROFITTING. Motor Protection Relay. Two mountings are available, Flush Rear Connection (EDPAR) or Projecting Rear Connection (SDPAR).

RETROFITTING. Motor Protection Relay. Two mountings are available, Flush Rear Connection (EDPAR) or Projecting Rear Connection (SDPAR). RETROFITTING Motor Protection Relay NPM800R (R2 case) and NPM800RE (R3 case) are dedicated to the refurbishment of 7000 series (R2 and R3 cases) of CEE relays providing the protection of medium voltage

More information

Wiring. Fuse 1 6.3A 230v in & motor. Fuse 2 1A 24v out. Fuse 3 250mA Brake & logic control. 0v PDM. Aux. Ch 2

Wiring. Fuse 1 6.3A 230v in & motor. Fuse 2 1A 24v out. Fuse 3 250mA Brake & logic control. 0v PDM. Aux. Ch 2 Easy MBB QRG Quick reference guides are not a replacement for the supplied instructions, they are supplementary Read and understand the installer warnings in the main instruction document first Always

More information

Microphone audio, from the MFJ-1278B to your transmitter. Ground, audio and PTT common. Push-to-talk, to allow the MFJ-1278B to key your transmitter.

Microphone audio, from the MFJ-1278B to your transmitter. Ground, audio and PTT common. Push-to-talk, to allow the MFJ-1278B to key your transmitter. Computer interfacing, covered in the previous chapter, is only half the interfacing task. The other half is connecting your MFJ-1278B to your radios. MFJ-1278B Radio Ports Interfacing the MFJ-1278B to

More information

SN AN READY AUDIO OUT GND

SN AN READY AUDIO OUT GND The Engineering Staff of TEXAS NSTRUMENTS Semiconductor Group SN 76489 AN DUAL-N-LNE PACKAGe (TOP View) FEATURES 02 1 16 VCC 3 Programmable Tone Generators Programmable White Noise Generator Programmable

More information

NERC Protection Coordination Webinar Series June 9, Phil Tatro Jon Gardell

NERC Protection Coordination Webinar Series June 9, Phil Tatro Jon Gardell Power Plant and Transmission System Protection Coordination GSU Phase Overcurrent (51T), GSU Ground Overcurrent (51TG), and Breaker Failure (50BF) Protection NERC Protection Coordination Webinar Series

More information

Inductive Loop Detector

Inductive Loop Detector Naztec Operations Manual For Inductive Loop Detector Model 722TXC TS1/TS2 April 2003 Published by: Naztec, Inc. 820 Park Two Drive Sugar Land, Texas 77478 Phone: (281) 240-7233 Fax: (281) 240-7238 Copyright

More information

SP980. Cordless Stereo 863MHZ. Speaker System. User s Manual INTRODUCTION FEATURES. Please read before using the equipment

SP980. Cordless Stereo 863MHZ. Speaker System. User s Manual INTRODUCTION FEATURES. Please read before using the equipment SP980 Cordless Stereo 863MHZ Speaker System INTRODUCTION This 863 MHz stereo wireless speaker system uses latest wireless technology that enables you to enjoy music and TV sound anywhere inside or outside

More information

E2 STATUS REPORTING AND CONTROL SYSTEM STATUS DESCRIPTION

E2 STATUS REPORTING AND CONTROL SYSTEM STATUS DESCRIPTION BELL SYSTEM PRACTCES AT&TCo Standard SECTON 20-644-4 ssue, April 975 E2 STATUS REPORTNG AND SYSTEM STATUS REPORTNG REMOTE DESCRPTON.,i) ~:.:..?,. 2. 3. 4. CONTENTS GENERAL.......... PHYSCAL DESCRPTON.....

More information

Data. Dr Murari Mohan Saha ABB AB. KTH/EH2740 Lecture 3. Data Acquisition Block. Logic. Measurement. S/H and A/D Converter. signal conditioner

Data. Dr Murari Mohan Saha ABB AB. KTH/EH2740 Lecture 3. Data Acquisition Block. Logic. Measurement. S/H and A/D Converter. signal conditioner Digital Protective Relay Dr Murari Mohan Saha ABB AB KTH/EH2740 Lecture 3 Introduction to Modern Power System Protection A digital protective relay is an industrial microprocessor system operating in real

More information

COPYRIGHTED MATERIAL. Index

COPYRIGHTED MATERIAL. Index Index Note: Bold italic type refers to entries in the Table of Contents, refers to a Standard Title and Reference number and # refers to a specific standard within the buff book 91, 40, 48* 100, 8, 22*,

More information

LBI-31564A. Mobile Communications. DELTA - SX MHz RADIO COMBINATIONS (NEGATIVE GROUND ONLY) Maintenance Manual

LBI-31564A. Mobile Communications. DELTA - SX MHz RADIO COMBINATIONS (NEGATIVE GROUND ONLY) Maintenance Manual A Mobile Communications DELTA - SX 136-174 MHz RADIO COMBINATIONS (NEGATIVE GROUND ONLY) Maintenance Manual TABLE OF CONTENTS MILITARY AND SYSTEM SPECIFICATIONS................................. 2-3 COMBINATION

More information

Department of Electronics & Telecommunication Engg. LAB MANUAL. B.Tech V Semester [ ] (Branch: ETE)

Department of Electronics & Telecommunication Engg. LAB MANUAL. B.Tech V Semester [ ] (Branch: ETE) Department of Electronics & Telecommunication Engg. LAB MANUAL SUBJECT:-DIGITAL COMMUNICATION SYSTEM [BTEC-501] B.Tech V Semester [2013-14] (Branch: ETE) KCT COLLEGE OF ENGG & TECH., FATEHGARH PUNJAB TECHNICAL

More information

TEN-TEc INSTRUCTION SHEET MODEL KRS-A

TEN-TEc INSTRUCTION SHEET MODEL KRS-A 3-75 TEN-TEc NSTRUCTON SHEET MODEL KRS-A, GENERAL The KRS-A is a solid state, integrated circuit electronic keyer incorporating a reed relay as the actual keying component. t can be used to key all gridblocked

More information

Appendix S: PROTECTION ALTERNATIVES FOR VARIOUS GENERATOR CONFIGURATIONS

Appendix S: PROTECTION ALTERNATIVES FOR VARIOUS GENERATOR CONFIGURATIONS Appendix S: PROTECTION ALTERNATIVES FOR VARIOUS GENERATOR CONFIGURATIONS S1. Standard Interconnection Methods with Typical Circuit Configuration for Single or Multiple Units Note: The protection requirements

More information

Transformer Protection

Transformer Protection Transformer Protection Transformer Protection Outline Fuses Protection Example Overcurrent Protection Differential Relaying Current Matching Phase Shift Compensation Tap Changing Under Load Magnetizing

More information

Protection Relays. U-MLEs-PLs-Ts. Ultra-Ts. DC SUBSTATION PROTECTIVE RELAY (single voltage Line Test) 32, 45, 49, 64, 76, 79, 80

Protection Relays. U-MLEs-PLs-Ts. Ultra-Ts. DC SUBSTATION PROTECTIVE RELAY (single voltage Line Test) 32, 45, 49, 64, 76, 79, 80 Ultra-Ts DC SUBSTATION PROTECTIVE RELAY (single voltage Line Test) 32, 45, 49, 64, 76, 79, 80 D.C. Feeder protection relay with setting parameters programmable locally or via serial communication. Suitable

More information

APPLICATION: The heart of the system is a DSR 100 Digital Static Regulator used in conjunction with standard SCR based rectifier bridges.

APPLICATION: The heart of the system is a DSR 100 Digital Static Regulator used in conjunction with standard SCR based rectifier bridges. APPLICATION: Basler Electric offers a New Line of digitally controlled brush (static) or brushless excitation systems designed for use with existing Hydro, Gas as well as Diesel driven generators requiring

More information

Distribution/Substation Transformer

Distribution/Substation Transformer Distribution/Substation Transformer Type VFI, Vacuum Fault Interrupter Transformer Option Functional Specification Guide Functional specification for 15 kv, 25 kv, or 35 kv vacuum fault interrupter distribution/substation

More information

SECTION LOW VOLTAGE ACTIVE HARMONIC FILTER SYSTEM NEMA 1 ENCLOSED

SECTION LOW VOLTAGE ACTIVE HARMONIC FILTER SYSTEM NEMA 1 ENCLOSED SECTION 16280 LOW VOLTAGE ACTIVE HARMONIC FILTER SYSTEM NEMA 1 ENCLOSED PART 1 - GENERAL 1.1 SUMMARY This specification defines the requirements for active harmonic filter systems in order to meet IEEE-519-2014

More information

USER'S MANUAL. Model : K

USER'S MANUAL. Model : K USER'S MANUAL Model : 2000-64K TM GINA MODEL 2000-64K Overview GINA Model 2000-64K is a stand-alone, high frequency data transceiver using spread spectrum technology. GINA 2000-64K capabilities include

More information

CHAPTER 4: 555 TIMER. Dr. Wan Mahani Hafizah binti Wan Mahmud

CHAPTER 4: 555 TIMER. Dr. Wan Mahani Hafizah binti Wan Mahmud CHAPTE 4: 555 TIME Dr. Wan Mahani Hafizah binti Wan Mahmud 555 TIME Introduction Pin configuration Basic architecture and operation Astable Operation Monostable Operation Timer in Triggering Circuits 555

More information

System Protection and Control Subcommittee

System Protection and Control Subcommittee Power Plant and Transmission System Protection Coordination Reverse Power (32), Negative Sequence Current (46), Inadvertent Energizing (50/27), Stator Ground Fault (59GN/27TH), Generator Differential (87G),

More information

STATIC VOLTAGE BALANCE 3S7932MA350

STATIC VOLTAGE BALANCE 3S7932MA350 GEK- 36539 @ 0 f GE DR deral ELECTRC COMPANY VE SYSTEMS DEPARTMENT SALEM, VA. 24153 STATC VOLTAGE BALANCE 3S7932MA350 RELAY GENERAL@ ELECTRC DATE(S) BASC SSUE 10/29/79 REVSON REVSON REVSON REVSON 4 i STATC

More information

which is used to shift the phase angle between the two sets of coils to produce torque.

which is used to shift the phase angle between the two sets of coils to produce torque. KLF-1 SCOPE This test procedure covers the testing and maintenance of the ABB KLF-1 loss of excitation relay. The Westinghouse Protective Relay Division was purchased by ABB, and new relays carry the ABB

More information

ECET 211 Electric Machines & Controls Lecture 2-1 (Part 1 of 3) Symbols and Drawing for Electric Motor Control Systems

ECET 211 Electric Machines & Controls Lecture 2-1 (Part 1 of 3) Symbols and Drawing for Electric Motor Control Systems ECET 211 Electric Machines & Controls Lecture 2-1 (Part 1 of 3) Symbols and Drawing for Electric Motor Control Systems Text Book: Chapter 2. Understanding Electrical Drawings, Electric Motors and Control

More information

Ethernet Coax Transceiver Interface

Ethernet Coax Transceiver Interface 1CY7B8392 Features Compliant with IEEE802.3 10BASE5 and 10BASE2 Pin compatible with the popular 8392 Internal squelch circuit to eliminate input noise Hybrid mode collision detect for extended distance

More information

Static Breaker Back-up Relay Type SBC Relay SBC231B

Static Breaker Back-up Relay Type SBC Relay SBC231B GEK 106210 Supplement GEK-100637 GE Power Management Static Breaker Back-up Relay Type SBC Relay SBC231B INSTRUCTIONS These instructions, GEK-106210 together with GEK-100637, constitute the complete instructions

More information

Module 9. Fault Type Form 4.X RELIABILITY ACCOUNTABILITY

Module 9. Fault Type Form 4.X RELIABILITY ACCOUNTABILITY Module 9 Fault Type Form 4.X 1 M9 Fault Type The descriptor of the fault, if any, associated with each Automatic Outage of an Element. 1. No fault 2. Phase-to-phase fault (P-P) 3. Single phase-to-ground

More information

CS-200. PORTABLE TRAFFIC LIGHT CONTROLLER (Software 1.05) OPERATION AND SERVICE MANUAL

CS-200. PORTABLE TRAFFIC LIGHT CONTROLLER (Software 1.05) OPERATION AND SERVICE MANUAL CS-200 PORTABLE TRAFFIC LIGHT CONTROLLER (Software 1.05) OPERATION AND SERVICE MANUAL CS-200 Operation and Service Manual Page 2 Manufactured by: LINCAST INTERNATIONAL PTY. LTD. 2/3 Sir Laurence Drive

More information

Using a Multiple Analog Input Distance Relay as a DFR

Using a Multiple Analog Input Distance Relay as a DFR Using a Multiple Analog Input Distance Relay as a DFR Dennis Denison Senior Transmission Specialist Entergy Rich Hunt, M.S., P.E. Senior Field Application Engineer NxtPhase T&D Corporation Presented at

More information

Power Plant and Transmission System Protection Coordination

Power Plant and Transmission System Protection Coordination Technical Reference Document Power Plant and Transmission System Protection Coordination NERC System Protection and Control Subcommittee Revision 1 July 2010 Table of Contents 1. Introduction... 1 1.1.

More information

Mastr III P25 Base Station Transmitter Tune-up Procedure

Mastr III P25 Base Station Transmitter Tune-up Procedure Mastr III P25 Base Station Transmitter Tune-up Procedure 1. Overview The Mastr III Base Station transmitter alignment is performed in several steps. First, the Transmit Synthesizer module is aligned to

More information

Instruction Manual T-800 Series Current Transmitter. Model T-800L Model T-800LT Model T-800TT

Instruction Manual T-800 Series Current Transmitter. Model T-800L Model T-800LT Model T-800TT Instruction Manual T-800 Series Current Transmitter Model T-800L Model T-800LT Model T-800TT M323 Rev G1 September 10, 2009 JOWA USA, Inc. 59 Porter Road Littleton, MA 01460-1431 USA Telephone: 978-486

More information

Sensor Options. Rev

Sensor Options. Rev Sensor Options Rev. 07.21.17 HALL-EFFECT SENSORS DH-X Dual Hall Effect Pickup Used with JV-CG and JV-KG (excluding JVM-01CG) The DH Dual Hall Effect Pickups are microprocessor-based sensors for use with

More information

Insertion/Extraction Tool and Replacement Tip Kits [ ]

Insertion/Extraction Tool and Replacement Tip Kits [ ] Inserton/Extracton Tool 91285-1 and Replacement Tp Kts 543382-[ ] Instructon Sheet 408-9404 19 JUN 12 PROPER USE GUIDELINES Cumulatve Trauma Dsorders can result from the prolonged use of manually powered

More information

WIRELESS STEREO WOODEN PANEL SPEAKER SYSTEM

WIRELESS STEREO WOODEN PANEL SPEAKER SYSTEM WIRELESS STEREO WOODEN PANEL SPEAKER SYSTEM Owner s Manual Please read before using the equipment INTRODUCTION The 863 MHz stereo wireless speaker system uses latest wireless technology that enables you

More information

Advanced Power Electronics Corp. APE2903 MICROPOWER VFM STEP-UP DC/DC CONVERTER TYPICAL APPLICATION ORDERING INFORMATION. Preliminary.

Advanced Power Electronics Corp. APE2903 MICROPOWER VFM STEP-UP DC/DC CONVERTER TYPICAL APPLICATION ORDERING INFORMATION. Preliminary. Preliminary MICROPOWER VFM STEP-UP DC/DC CONVERTER FEATURES Very Low Supply Current Regulated Output Voltage Wide Range of Output Voltage is Available from 2.2V to 5.0V by 0.1V Steps Output Voltage Accuracy

More information

ACCELERATOR COMPUTER SECTOR MEMORY* W. C. Struven Stanford Linear Accelerator Center Stanford University, Stanford, California 94305

ACCELERATOR COMPUTER SECTOR MEMORY* W. C. Struven Stanford Linear Accelerator Center Stanford University, Stanford, California 94305 SLAC-PUB-758 June 1970 ( A.C C) *.a.. ACCELERATOR COMPUTER SECTOR MEMORY* W. C. Struven Stanford Linear Accelerator Center Stanford University, Stanford, California 94305 ntroduction The accelerator control

More information

Protection Relays. U-MLEs-PLv-Ts. Ultra-Ts. DC SUBSTATION PROTECTIVE RELAY (double voltage Line Test) 32, 45, 49, 64, 76, 79, 80

Protection Relays. U-MLEs-PLv-Ts. Ultra-Ts. DC SUBSTATION PROTECTIVE RELAY (double voltage Line Test) 32, 45, 49, 64, 76, 79, 80 Ultra-Ts DC SUBSTATION PROTECTIVE RELAY (double voltage Line Test) 32, 45, 49, 64, 76, 79, 80 D.C. Feeder protection relay with setting parameters programmable locally or via serial communication. Suitable

More information

www. ElectricalPartManuals. com Transformer Differential Relay MD32T Transformer Differential Relay

www. ElectricalPartManuals. com Transformer Differential Relay MD32T Transformer Differential Relay Transformer Differential Relay The MD3T Transformer Differential Relay is a member of Cooper Power Systems Edison line of microprocessor based protective relays. The MD3T relay offers the following functions:

More information