712 Conductometer Annex to the Instructions for use

Size: px
Start display at page:

Download "712 Conductometer Annex to the Instructions for use"

Transcription

1 METROHM Ltd. CH-9101 Herisau (Switzerland) 712 Cductometer Annex to the Instructis for use In the 712 Cductometer the program versi is installed as standard from series 13 upwards. With this versi the automatic switch-over of the measuring range can be given a bottom limit. This makes it possible to better follow very rapid changes in cductivity, such as occur when calcium hydroxide is dissolved in distilled water. A further change affects the Pt temperature sensor: it is now possible to correct an set error. The correspding innovatis together with some correctis and additis to Instructis for use are described below; the page numbers mentied refer to the page numbers in the Instructis for use. Measuring cductivity and ph in the same vessel p. 9 In practice the circuit shown in Fig. 7 for the simultaneous measurement of cductivity (with 712) and ph (with Titrino) leads to problems with earthing loops which falsify the measurements obtained. As a result this circuit can no lger be recommended. Whenever possible you should use two different vessels for measuring the cductivity and ph, or alternatively use the Titroprocessor 726 instead of the Titrino as in this instrument the measuring inputs are electrically isolated. Cnecting printers p The following table ctains informati about the cnecti of some selected printers. Setting the RS232 parameters under ">cfig/rs232 settings" is the same for all printers and is therefore ly shown for the IBM Proprinter. Printer Cable RS232 settings Settings printer IBM Proprinter >cfig/printer send to : with 6-pin round cnector with additial serial #8148 IBM >cfig/rs232 settings baud rate: 9600 data bit: 8 stop bit: 1 parity: ne handshake: Hws >cfig/printer >cfig/printer SW1 SW Settings of the DIP switches the : SW1 SW Cductometer,

2 Printer Cable RS232 settings Settings printer LX >cfig/printer and Can printers with parallel DPU-411 DPU-414 Citizen IDP562-RS Deskjet with serial Laserjet with serial Deskjet/ Laserjet with parallel Serial/ parallel cverter >cfig/printer >cfig/printer >cfig/printer >cfig/printer or adapter cable 25-pin neg./9-pin pos. (e.g. C2933A) Adapter cable 25-pin neg./9-pin pos. (e.g. C2933A) Serial/ parallel cverter >cfig/printer Citizen >cfig/printer >cfig/printer DIP01 DIP the printer will be automatically set to the natial character sets in accordance with the set dialog language. Dip SW-1 Dip SW-2 Dip SW-3 1 ON ON 2 ON ON 3 ON ON ON 4 ON ON 5 ON ON 6 ON ON 7 ON ON 8 ON ON the printer will be automatically set to the natial character sets in accordance with the set dialog language. SSW1 ON the printer can be changed to the natial character sets ly by setting the DIP switches 4 and 5 in the printer: 4 5 Character set open open USA closed closed Great Britain closed open France open closed Germany Spanish does not have its own character set (it is best to select French). A B Cductometer,

3 Changing the dialog display p. 14 With the measuring range limit switched, the lowest measuring range is shown the bottom left in the dialog display in the basic cditi of the cductivity measurement instead of the cell cstant, e.g.: 20.0 C 200 ms 2.00 %/ C Dialog display with measuring range limit Offset correcti for temperature sensor p. 29 A new block ">cfig/pt sensor is now present under the key <cfig>; the two following parameters can be entered in this block: >cfig/pt sensor Pt id. xxxxxxxxxx Identificati for Pt sensor Character string for identificati of the temperature sensor (max. 10 characters, entry see Sect ). This identificati appears in the print head as so as a Pt sensor is cnected. >cfig/pt sensor Pt correcti 0.0 C C Offset correcti for Pt sensor The entered value describes the difference between the set temperature T set measured with a comparis thermometer and the actual temperature T act measured by the Pt sensor: Pt correcti = T set T act If the Pt correcti is 0.0 C then the correcti value is added to the measured value and the set temperature is displayed. In this case an " * " appears in the display before the temperature value. The correcti value also appears in the print head as so as a Pt sensor is cnected. New date format p. 29 The date is now entered and printed out with 4 places provided for the year. >cfig/auxiliaries date YYYY-MM-DD Date Current date with numeric data for year (YYYY), mth (MM) and day (DD). New parameters for range limit p. 33 Under the key <cd param> the following parameter is displayed again at the end of the block ">cd/parameters : >cd/parameters range limit: 2 µs, 20 µs, 200 µs, 2 ms, 20 ms, 200 ms, Range limit The value entered describes the lowest measuring range for the automatic switch-over. Automatic switch-over in the entire range (as before) 712 Cductometer,

4 Temperature display with Pt correcti p. 49 If a Pt correcti 0.0 C is entered then the dialog display alters as follows: * 24.7 C /cm 2.00 %/ C Dialog display in main measuring mode "Cductivity measurement" In the 1 st line an asterisk " * " appears in frt of the temperature value. Pt100 Pt correcti 1.2 C Dialog display in main measuring mode "Temperature measurement" The entered value for the Pt correcti appears in the 2 nd line. Display of the measuring range p. 60 Under the key <info> the currently applicable measuring range is displayed again after the measuring frequency: measuring range 200 ms 2 µs, 20 µs, 200 µs, 2 ms, 20 ms, 200 ms Current measuring range The currently applicable measuring range is displayed. Alteratis in the measurement output and curve plot p If a Pt sensor is cnected to Cductometer 712 then when measurements and curves are outputted the two parameters "Pt id." and "Pt correcti" will be printed out in the print head. New error messages p. 75 The following two new error messages can now be outputted via the RS232 : Error Meaning Exit/Corrective acti E231 EEPROM block error Pt correcti <quit>, reenter values for this block E238 EEPROM block error instrument number <quit>, reenter instrument number New remote ctrol commands p. 76 The following remote ctrol commands are new: &Cductivity.Parameter.RangeLimit &Cfig.Tempsensor.SensorId &Cfig.Tempsensor.Correcti &Info.ActualInfo.Butt.ActRange Measuring range limit (2/20/200 µs, 2/20/200 ms, ) Identificati for Pt sensor (max. 10 ASCII characters) Offset correcti for Pt sensor ( C) Current measuring range Cductometer,

5 New entry system for diagnosis p. 101 The instrument is prepared for diagnosis as follows (point 1): 1. Switch mains. 2. Remove all external cnectis from rear panel except the mains cable. 3. Press key <9> and switch mains supply. Keep key <9> pressed down until the following display appears: initializati EEPROM? ENTER>yes '9'>diagnosis ENTER Re-initializati (access ly for service persnel with safety code) 9 Entry to diagnosis 4. Press key <9>. The following display appears: diagnosis >EEPROM initializati Measuring errors for temperature p. 111 The measuring errors for temperature measurement have been newly defined as follows: C ± 0.2 C/100 C C ± 0.2 C C ± 0.5 C/100 C Alteratis to the optial accessories p. 115 In additi to the optial accessories listed in Sect the following accessories are also available: Immersi Cell with fixed cable (1 m, 2 cnector B); cell cstant c 1 cm 1 ; shaft length 108 mm; largest diameter 20 mm; minimum immersi depth 50 mm; electrodes not glazed Immersi Cell with fixed cable (1 m, 2 cnector B); cell cstant c 10 cm 1 ; shaft length 125 mm; largest diameter 20 mm; minimum immersi depth 80 mm Immersi Cell with integrated Pt 1000 temperature sensor with fixed cable (1.2 m, 2 cnector B); cell cstant c 0.8 cm 1 ; shaft length 125 mm; largest diameter 12 mm; minimum immersi depth 30 mm Pt 1000 Resistance Thermometer for sample changer with plug-in head G and adjustable SGJ sleeve; largest diameter 12 mm; minimum immersi depth 20 mm Cable for Pt 1000 Sensor Cable for Pt 1000 Resistance Thermometers ( and ); length 2 m; 2 cnector B 712 Cductometer,

Manual Traffic Detector - VEK M4D

Manual Traffic Detector - VEK M4D Traffic Detector - 2005-08-29 M4D_Beschr_engl_0508.DOC Note Copyright 2005 by FEIG ELECTRONIC GmbH Lange Straße 4 D - 35781 Weilburg The specificatis ctained in this document may be changed without prior

More information

SKJ. J1939 CANBus Output Signal. Linear Position to 400 inches (10 m) Compact Design Simple To Install User Adjustable Measuring Cable Orientation

SKJ. J1939 CANBus Output Signal. Linear Position to 400 inches (10 m) Compact Design Simple To Install User Adjustable Measuring Cable Orientation SKJ J939 CANBus Output Signal Linear Positi to 4 inches ( m) Compact Design Simple To Install User Adjustable Measuring Cable Orientati SPECIFICATIONS Stroke Range Optis 25 inches (6.4 m), 4 inches (.2

More information

Manual GBR. Traffic detector VEK MNE 1 / VEK MNE2

Manual GBR. Traffic detector VEK MNE 1 / VEK MNE2 Manual Traffic detector VEK MNE NE1 1 / VEK MNE2 Notes Copyright 2015 by FEIG ELECTRONIC GmbH Lange Straße 4 D-35781 Weilburg Tel.: +49 6471 3109-0 www.feig.de Versi: 2015-09-14 This editi renders all

More information

Connection between thermal printer DPU-414 and measuring equipment

Connection between thermal printer DPU-414 and measuring equipment Connection between thermal printer DPU- and measuring equipment When connecting the DPU- to various measuring instruments, function settings at the DPU- must be changed. The procedure for changing settings

More information

E297S USER'S GUIDE. Overview. Fast Start. Quantum Research Group Ltd.

E297S USER'S GUIDE. Overview. Fast Start. Quantum Research Group Ltd. Overview Fast Start The E97s board is designed for rapid development and programming of the QTM000 module for capacitancebased sensing systems. It includes all the circuitry required to make a fully functiing

More information

MICRO-CONTROLLER X (48mm 48mm)

MICRO-CONTROLLER X (48mm 48mm) PX series Digital temperature Ctroller DATA SHEET Socket Type With frt dimensis of 48 48mm, this socket type temperature ctroller enables On-Off ctrol, PID ctrol or 8-step ramp/soak functi, using thermocouple,

More information

ProHelp Systems MIU 10X/98 WIRING / INSTALLATION INSTRUCTIONS

ProHelp Systems MIU 10X/98 WIRING / INSTALLATION INSTRUCTIONS ProHelp Systems MIU 10X/98 WIRING / INSTALLATI INSTRUCTIS 2 MIU-10X /5XS SETUP AND CFIGURATI MIU-10X Configuration and Diagnostics Screen Upon boot-up the MIU-10X first runs a self-diagnosis routine to

More information

Technical data. General specifications. Indicators/operating means. 95 Hz Multiplex operation 95 Hz / n, n = number of sensors, n 5

Technical data. General specifications. Indicators/operating means. 95 Hz Multiplex operation 95 Hz / n, n = number of sensors, n 5 Model Number Single head system Features Parameterizati interface for the applicati-specific adjustment of the sensor setting via the service program ULTRA 3000 programmable switch outputs Latching mode

More information

ICAM. Electronics & Software. Industrial Charge Amplifier for Applications in Manufacturing. Type 5073A...

ICAM. Electronics & Software. Industrial Charge Amplifier for Applications in Manufacturing. Type 5073A... Electronics & Software ICAM Type 5073A... Industrial Charge Amplifier for Applications in Manufacturing The ICAM charge amplifier (Industrial Charge Amplifier Manufacturing) converts the piezoelectric

More information

FRUIT BONUS 2 nd Generation 2004 AMCOE INC.

FRUIT BONUS 2 nd Generation 2004 AMCOE INC. PIN PARTS SIDE SOLDER SIDE PIN 1 VIDEO RED VIDEO GREEN 1 2 VIDEO BLUE VIDEO SYNC 2 3 SPEAKER + SPEAKER - 3 4 EXTRA - 4 5 EXTRA - STOP 2 EXTRA - ALL STOP 5 6 EXTRA - STOP 3 6 7 TICKET OUT BUTTON - panel

More information

TIGER HOOK 2004 AMCOE INC.

TIGER HOOK 2004 AMCOE INC. TIGER HOOK 2004 AMCOE INC. PIN PARTS SIDE SOLDER SIDE PIN 1 VIDEO RED VIDEO GREEN 1 2 VIDEO BLUE VIDEO SYNC 2 3 SPEAKER + SPEAKER - 3 4 EXTRA - 4 5 EXTRA - STOP 2 EXTRA - ALL STOP 5 6 EXTRA - STOP 3 6

More information

High-quality digital indicator for panel mounting Model DI35-M, with multi-function input Model DI35-D, with two inputs for standard signals

High-quality digital indicator for panel mounting Model DI35-M, with multi-function input Model DI35-D, with two inputs for standard signals Accessories High-quality digital indicator for panel mounting Model DI35-M, with multi-function input Model DI35-D, with two inputs for standard signals WIKA data sheet AC 80.03 Applications Machine building

More information

workshop socket fusion tools

workshop socket fusion tools workshop socket fusi tools Type 7511 Workshop Socket Fusi Tool Suitable for PE, PB, PP and PVDF Size range from 20mm O.D. to 75mm O.D. The Widos Type 7511 socket fusi welding machine will weld piping systems

More information

INSTRUCTION MANUAL DISSOLVED OXYGEN-METER MODEL CDO-01

INSTRUCTION MANUAL DISSOLVED OXYGEN-METER MODEL CDO-01 INSTRUCTION MANUAL DISSOLVED OXYGEN-METER MODEL CDO-01 EL-221, MIDC Electronic Zone, Mhape, Navi Mumbai-400710. Tel: 022- 61393000 CHAPTER 1 INTRODUCTION Contech CDO-01 measures Dissolved Oxygen and temperature

More information

Technical Manual. Standard Communication Protocol TA3840C

Technical Manual. Standard Communication Protocol TA3840C TA3840C Technical Manual SAS au Capital de 2 158 244-444 871 933 R.C.S. Bourges - APE : 2651B Headquarter : 9, rue Isaac Newton - 18000 Bourges - France Technical Manual TA3840C 1 st Edition Released February

More information

Interface: Serial EIA RS-232D/CCITT V.24, DCE; RTS/CTS delay 0,8 or 64 ms (user-selectable).

Interface: Serial EIA RS-232D/CCITT V.24, DCE; RTS/CTS delay 0,8 or 64 ms (user-selectable). BLACK BOX PWR RTS TD-1 RD-1 TD-2 DCD RD-2 TEST DIG ANA REM LDM-MR 19.2 REM ANA DIG AGC 2/4 WIRE ABLE / ABLE SWITCHES 2 W 4 W 1 2 3 4 CARRIER LEVEL 0 dbm -3 dbm -6 dbm -9 dbm PIN 21 (RLB) RPF PIN 18 AN.

More information

Serial Control Hardware (RS-485)

Serial Control Hardware (RS-485) Serial Control Hardware (RS-485) The RS-485 port is available on either of the RJ45 connectors on the back panel of the unit. The 485 network operates at 19.2 kbaud, 8 bits, 1 stop bit/no parity/no hardware

More information

TECHNICAL. ZPI-4 Four Zone Paging Interface. Four Zone Paging Interface

TECHNICAL. ZPI-4 Four Zone Paging Interface. Four Zone Paging Interface TECHNICAL Practice TELECOM SOLUTIS FOR THE ST CENTURY ZPI- Four Ze Interface December 9, 009 Four Ze Interface The ZPI- is a four-ze touch te ctrolled paging system capable of switching a line level signal

More information

Model 963PB 12 Channel Analog Current Input Model 964PB 12 Channel Analog Voltage Input

Model 963PB 12 Channel Analog Current Input Model 964PB 12 Channel Analog Voltage Input BusWorks 900PB Series ProfiBus/RS485 Network I/O Modules Model 963PB 12 Channel Analog Current Input Model 964PB 12 Channel Analog Voltage Input USER S MANUAL ACROMAG INCORPORATED Tel: (248) 624-1541 30765

More information

High-quality digital indicator for panel mounting Model DI35-M, with multi-function input Model DI35-D, with two inputs for standard signals

High-quality digital indicator for panel mounting Model DI35-M, with multi-function input Model DI35-D, with two inputs for standard signals Accessories Highquality digital indicator for panel mounting Model DI35M, with multifunction input Model DI35D, with two inputs for standard signals WIKA data sheet AC 80.03 Applications Machine building

More information

C.A 6115N. Safety at all costs. IEE 16th: Electrical installation IEC/EN I E C. Insulation RCD. Earth. Loop. Continuity.

C.A 6115N. Safety at all costs. IEE 16th: Electrical installation IEC/EN I E C. Insulation RCD. Earth. Loop. Continuity. IEE 16th: Safety at all costs C.A 6115N Electrical installation Insulation RCD Earth Loop Continuity Phase rotation I E C CONFIRMS TO CONFIRMS TO IEC/EN 61557 1010-1 III 300V Cat Cat The most complete

More information

Conductivity measurement

Conductivity measurement Conductivity measurement Content 95 Applications and meters overview 96 Benchtop conductivity meters 96 inolab Multi IDS digital 97 inolab analogue 100 Portable conductivity meters 100 MultiLine IDS digital

More information

WTDIN-M. eeder. Digital Input Module. Technologies FEATURES SPECIFICATIONS DESCRIPTION. Weeder Technologies

WTDIN-M. eeder. Digital Input Module. Technologies FEATURES SPECIFICATIONS DESCRIPTION. Weeder Technologies eeder Technologies 90-A Beal Pkwy NW, Fort Walton Beach, FL 32548 www.weedtech.com 850-863-5723 Digital Input Module FEATURES 8 wide-range digital input channels with high voltage transient protection.

More information

Installation and operating instructions. Barriers ES 25 ES 80 Part 2 Controller MO 64

Installation and operating instructions. Barriers ES 25 ES 80 Part 2 Controller MO 64 Installati and operating instructis Barriers ES 25 ES 80 Part 2 Ctroller MO 64 Translati of original installati and operating instructis D-ID: V1_3 01.14 ELKA-Torantriebe GmbH u. Co. Betriebs KG Phe: +49-(0)

More information

ROTRONIC HygroClip Digital Input / Output

ROTRONIC HygroClip Digital Input / Output ROTRONIC HygroClip Digital Input / Output OEM customers that use the HygroClip have the choice of using either the analog humidity and temperature output signals or the digital signal input / output (DIO).

More information

2F. No.25, Industry E. 9 th Rd., Science-Based Industrial Park, Hsinchu, Taiwan Application Note of OGM220, AN001 V1.8

2F. No.25, Industry E. 9 th Rd., Science-Based Industrial Park, Hsinchu, Taiwan Application Note of OGM220, AN001 V1.8 Application Note of OGM220, AN001 V1.8 1.0 Introduction OGM220 series is a dual channels NDIR module having a digital output directly proportional to CO2 concentration. OGM220 is designed for multi-dropped

More information

NEW. Data Sheet Fieldbus Components. Fieldbus Foundation Connectors

NEW. Data Sheet Fieldbus Components. Fieldbus Foundation Connectors Data heet ieldbus Compents ieldbus oundati Cnectors In aluminium and stainless steel housing With overvoltage protecti With spur line fusing Ex-certified versi ccessories NEW The C fieldbus cnectors are

More information

RI-R11 series RI-R11D series

RI-R11 series RI-R11D series RIR series RIRD series INSULATI MITORING VERSIS FOR NETWORKS dc MAX V GENERAL MODELS The devices allow perent mitoring of insulati of electrical networks in directcurrent current isolated earth (IT networks).

More information

COIN COUNTER & SORTER

COIN COUNTER & SORTER MANUAL SAFESCAN 12 COIN COUNTER & SORTER www.safescan.com 1 INTRODUCTION Thank you for purchasing the Safescan 12 Coin Counter and Sorter, a product of outstanding ease-of-use and quality. The Safescan

More information

Sodium Thiosulphate and hydrochloric acid

Sodium Thiosulphate and hydrochloric acid Sodium Thiosulphate and hydrochloric acid Introduction The rate of reaction can be altered by varying temperature or concentration, or by changing the surface area of a solid reactant, or by adding a catalyst.

More information

JUMO dtrans T04 Four-wire Transmitter, settable via DIP switch/pc setup program

JUMO dtrans T04 Four-wire Transmitter, settable via DIP switch/pc setup program JUMO GmbH & Co. KG Delivery address:mackenrodtstraße 14, 36039 Fulda, Germany Postal address: 36035 Fulda, Germany Phone: +49 661 6003-0 Fax: +49 661 6003-607 e-mail: mail@jumo.net Internet: www.jumo.net

More information

GT SERIES. QuikStart Installation Guide #95228

GT SERIES. QuikStart Installation Guide #95228 #95228 GT SERIES QuikStart Installation Guide ATTENTI: This is an abbreviated Installation Manual, addressing wiring and programming of the GT Series. The complete GT Series Installation Manual is located

More information

Four Zone Paging Interface

Four Zone Paging Interface Designed, Manufactured and Supported in the USA PRODUCT MANUAL COMMUNICATION & SECURITY SOLUTIONS ZPI-4 Four Ze Interface January 27, 2016 Four Ze Interface The ZPI-4 is a four-ze touch te ctrolled paging

More information

Digital insulation tester

Digital insulation tester Digital insulation tester C.A 6505 > > Insulation at 5 kv > > Wide measurement range from 10 kω to 10 TΩ > > Large backlit LCD screen, with digital display and bargraph > > Fixed test voltages and programmable

More information

HURRICANE Radio Modem. FULL DUPLEX Radio MODEM

HURRICANE Radio Modem. FULL DUPLEX Radio MODEM FULL DUPLEX Radio MODEM Direct Cable Replacement Range 2KM RS232 / RS485 / USB Host Data Rates up to 38,400 Baud RF Data Rates to 115200Kbps Waterproof IP68 Enclosure 8 User Selectable Channels CE Compliant

More information

WTDOT-M. eeder. Digital Output Module. Technologies FEATURES SPECIFICATIONS DESCRIPTION. Weeder Technologies

WTDOT-M. eeder. Digital Output Module. Technologies FEATURES SPECIFICATIONS DESCRIPTION. Weeder Technologies eeder Technologies 90-A Beal Pkwy NW, Fort Walton Beach, FL 32548 www.weedtech.com 850-863-5723 Digital Output Module FEATURES 8 high-current open-collector output channels with automatic overload shutdown.

More information

UNIGYR Building Level Network, PROFIBUS X1 V1 E4

UNIGYR Building Level Network, PROFIBUS X1 V1 E4 8 023 IGYR Building Level Network, PROFIBUS The Building Level Network (BLN) serves to exchange building management data between process units and the PC operator station "IGYR Insight". In IGYR, PROFIBUS

More information

Spa Control Troubleshooting Guide

Spa Control Troubleshooting Guide Spa Control Troubleshooting Guide Model: RS, Voltage: 0V Major System Components TOPSIDE PANEL SYSTEM PACK FAULT CIRCUIT INTERRUPTER (GFCI) GFCI models vary in size and style. Your GFCI may look different.

More information

High-precision process calibrator Model CED7000

High-precision process calibrator Model CED7000 Calibration technology High-precision process calibrator Model CED7000 WIKA data sheet CT 85.51 Applications Research and development laboratories Calibration service companies and service industry Industry

More information

User manual. Inclinometer with Analog-RS232-Interface IK360

User manual. Inclinometer with Analog-RS232-Interface IK360 User manual Inclinometer with Analog-RS232-Interface IK360 Table of content 1 GENERAL SAFETY ADVICE... 3 2 INTRODUCTION... 4 2.1 IK360... 4 2.2 ANALOG INTERFACE... 4 2.3 IK360 ANALOG... 4 3 INSTALLATION...

More information

Safety for men and machines. DNDS Modular in metal housing. Original Instruction manual

Safety for men and machines. DNDS Modular in metal housing. Original Instruction manual Safety for men and machines DNDS Modular in metal housing Original Instructi manual DlNA Elektrik GmbH Esslinger Straße, 79 Wolfschlugen Tel. 070/9 7-0, Fax 070/9 7- www.dinaelektrik.de, info@dinaelektrik.de

More information

Specification and Installation Tips for Capacitive Voltage Detecting and Monitoring System CAPDIS-Sx+ (R3)

Specification and Installation Tips for Capacitive Voltage Detecting and Monitoring System CAPDIS-Sx+ (R3) Specicati and Installati Tips for Capacitive Voltage Detecting and Mitoring System CAPDIS-S+ (R3) 1. General CAPDIS-S1+ is an integrated voltage detecting system for voltage detecting in medium voltage

More information

Test Report. 3 rd ITU Test Event: Performance Assessment of Mobile Phones as Gateways to Car Hands-free Systems November 2016

Test Report. 3 rd ITU Test Event: Performance Assessment of Mobile Phones as Gateways to Car Hands-free Systems November 2016 Test Report rd ITU Test Event: Performance Assessment of Mobile Phes as Gateways to Car Hands-free Systems 15-16 November 216 ITU 217 Test Report: Performance Assessment of Mobile Phes as Gateways to Car

More information

EE 314 Spring 2003 Microprocessor Systems

EE 314 Spring 2003 Microprocessor Systems EE 314 Spring 2003 Microprocessor Systems Laboratory Project #9 Closed Loop Control Overview and Introduction This project will bring together several pieces of software and draw on knowledge gained in

More information

SECTION 8 Communications Characteristics (Reference)

SECTION 8 Communications Characteristics (Reference) SECTION 8 Communications Characteristics (Reference) This section provides V700 communications characteristics such as communications ranges and communications times. 8-1 Maximum Communications Distance.........................................

More information

COMPACT-LINE. KOBO-pH Transmitter for ph-value Model APM-Z

COMPACT-LINE. KOBO-pH Transmitter for ph-value Model APM-Z KOBO-pH Transmitter for ph-value Model APM-Z measuring monitoring analysing COMPACT-LINE Measuring range ph -1 to 14 Switchable from ph to ORP Display of ph value, mv/orp (Oxidation Reduction Potential)

More information

Model 144H NEW. PC-Programmable Temperature Transmitter. Product Data Sheet

Model 144H NEW. PC-Programmable Temperature Transmitter. Product Data Sheet Product Data Sheet 00813-0101-4796 Model 144H PC-Programmable Temperature Transmitter FEATURES Configurable using the Model 144C Configuration Interface hardware and software Programmable via standard

More information

A S 8 Operating Instructions

A S 8 Operating Instructions A S 8 Operating Instructions Volutronic PAGE 2 BAS8-02.02-GB 1. SAFETY 4 2. DESCRIPTION 5 3. CONNECTING THE AS8 6 3.1 Connecting the voltage supply 6 3.2 Connecting the volume counter 6 3.2.1 How is the

More information

13. OP-03 RS-232C SERIAL INTERFACE

13. OP-03 RS-232C SERIAL INTERFACE This document hosted by: www.oldwillknottscales.com 13. OP-03 RS-232C SERIAL INTERFACE This interface allows the HC-i series to be connected with a multifunction printer or a personal computer. The OP-03

More information

DMS-40PC-4/20S 4½ Digit, 4-20mA Input, LED Display Meters

DMS-40PC-4/20S 4½ Digit, 4-20mA Input, LED Display Meters FEATURES Full-size, 0.52" (3.2mm) high, LED digits +7.5-32Vdc model draws 30mA +24V Isolated-power models Dip-switch selectable range, offset, and decimal points Non-interacting, 20-turn, gain (span) and

More information

MADEinUSA OPERATOR S MANUAL. RS232 Interface Rev. A

MADEinUSA OPERATOR S MANUAL. RS232 Interface Rev. A MADEinUSA OPERATOR S MANUAL RS232 Interface 92-3006 Rev. A www.iradion.com Iradion Laser, Inc. 51 Industrial Dr. N. Smithfield, RI 02896 (410) 762-5100 Table of Contents 1. Overview... 2 2. Equipment Required...

More information

SCHMIDT Flow Sensor SS SS FB

SCHMIDT Flow Sensor SS SS FB Product description Flow sensor with integrated microcontroller transducer for the measurement of air-flow velocity and for the determination of the flow rate and flow volume. The aerodynamically styled

More information

Luminescence Sensors. Operating Instruction

Luminescence Sensors. Operating Instruction A1P05 A1P16 A2P05 A2P16 Luminescence Sensors Operating Instruction SAP-No. 80204 Stand: 05.07.2012 2 Index 1. Proper Use 3 2. Safety Precautions 3 3. LED Warning 3 4. EC Declaration of Conformity 3 5.

More information

COMPACT-LINE. KOBO-RP Transmitter for ORP Model ARM-Z

COMPACT-LINE. KOBO-RP Transmitter for ORP Model ARM-Z KOBO-RP Transmitter for ORP Model ARM-Z measuring monitoring analysing COMPACT-LINE Measuring range -1999 to +1999 mv Switchable from ORP to ph ph or mv/orp (Oxidation Reduction Potential) and temperature

More information

Ø20mm (.79-in) 1954 n n n n n n n n n n n n n n. E1954 n n n n n n n gcm 2

Ø20mm (.79-in) 1954 n n n n n n n n n n n n n n. E1954 n n n n n n n gcm 2 HAYD: 03 756 744 G4 9000 Series: Ø 0 mm (.79-in) Can-Stack Stepper Motor Linear Actuator Haydon 9000 Series generates the highest force of any similar size linear actuator stepper motor. Utilizing high

More information

M O D U L E - 7 D Model CS-CAL/DLIU V6.0 Operator s Manual

M O D U L E - 7 D Model CS-CAL/DLIU V6.0 Operator s Manual O P E R A T I O N S A N D P R O C E D U R E S F O R C S - C A L / D L I U V 6. 0 A N D A C C E S S O R I E S Model CS-CAL/DLIU V6.0 Visual screen display allows easy step-by-step operation Rechargeable

More information

SCHMIDT Flow Sensor SS 25.60

SCHMIDT Flow Sensor SS 25.60 Product description Product advantages Form 107/06/09/1000/3 Art. No. 511 047.02 A Data subject to change The flow sensor is a mass flow sensor (thermal anemometer), designed for use in oxygen. Due to

More information

3 Ex i Isolators. Temperature Transmitter without Output 0/ ma, with Limit Value Contact (Field Circuit Ex i) Type 9182/.

3 Ex i Isolators. Temperature Transmitter without Output 0/ ma, with Limit Value Contact (Field Circuit Ex i) Type 9182/. Ex i Isolators Temperature Transmitter without Output 0/4... 20 ma, with Limit Value Contact Field Circuit Ex i) One unit for nearly all temperature sensors indivdually configurable Intrinsically safe

More information

WTPCT-M. eeder. Pulse Counter/Timer Module. Technologies FEATURES SPECIFICATIONS DESCRIPTION. Weeder Technologies

WTPCT-M. eeder. Pulse Counter/Timer Module. Technologies FEATURES SPECIFICATIONS DESCRIPTION. Weeder Technologies eeder Technologies 90-A Beal Pkwy NW, Fort Walton Beach, FL 32548 www.weedtech.com 850-863-5723 Pulse Counter/Timer Module FEATURES Reads frequency from 0.50000 to 1,400,000 Hz using 5 digit resolution

More information

Technical Description and User Manual E-band CW power meter DPM-12 s/n N-1204/21-T

Technical Description and User Manual E-band CW power meter DPM-12 s/n N-1204/21-T ELVA-1 Microwave Ltd. S.A. Mm-wave Division e-mail: sales@elva-1.com Internet: http://www.elva-1.com/ Technical Description and User Manual E-band CW power meter DPM-12 s/n N-1204/21-T 1 Specifications

More information

Bedienungsanleitung Operating manual Mode d emploi Instrucciones de operación

Bedienungsanleitung Operating manual Mode d emploi Instrucciones de operación Bedienungsanleitung Operating manual Mode d emploi Instrucciones de operación ba7542defs M PRT CAL STO O ESC Universal-Taschenmessgerät Seite 3 Universal Pocket Meter Page 7 Instrument de poche universel

More information

Model FLSC-C1-LIQ. Microprocessor Based Loop Powered Transmitter

Model FLSC-C1-LIQ. Microprocessor Based Loop Powered Transmitter Model FLSC-C1-LIQ Microprocessor Based Loop Powered Transmitter CONTENTS 1. Introduction ------------------------------------------------------------ 2 2. Specifications-----------------------------------------------------------

More information

User Manual Diezel Hagen Amplifier

User Manual Diezel Hagen Amplifier User Manual Diezel Hagen Amplifier Table of Ctents Chapter One: Safety 1.1 Safety Warnings Chapter Two: Using Your Hagen 2.1 Mains Cnectis, Power and Standby 2.1.1 Mains/cnect to power outlet 2.1.2 Power

More information

Kelba (Australia) Pty Ltd. PA8101S Manual ~ TABLE OF CONTENTS

Kelba (Australia) Pty Ltd. PA8101S Manual ~ TABLE OF CONTENTS Kelba (Australia) Pty Ltd Tel: Int 61 2 9476 4544 Web: www.kelba.com Email: Kelba@bigpond.net.au PA8101S Manual ~ TABLE OF CONTENTS Chapter 1: Introduction to the PA8101S Indicator (1) Chapter 2: Panel

More information

3 Ex i Isolators. Temperature Transmitter with Output 0/ ma, without Limit Value Contact (Field Circuit Ex i) Type 9182/.0-5.

3 Ex i Isolators. Temperature Transmitter with Output 0/ ma, without Limit Value Contact (Field Circuit Ex i) Type 9182/.0-5. Ex i Isolators Temperature Transmitter with Output 0/4... 20 ma, without Limit Value Contact Field Circuit Ex i) One unit for nearly all temperature sensors indivdually configurable Intrinsically safe

More information

Condumax W CLS19. Technical Information. Conductivity sensors Two-electrode sensors with cell constants k = 0.01 cm 1 or k = 0.

Condumax W CLS19. Technical Information. Conductivity sensors Two-electrode sensors with cell constants k = 0.01 cm 1 or k = 0. Technical Information Condumax W CLS9 Conductivity sensors Two-electrode sensors with cell constants k = 0.0 cm or k = 0. cm Application Measurement in pure and ultrapure water: Monitoring ion exchangers

More information

Channels that are not occupied by temperature sensors, can take over alternative functions:

Channels that are not occupied by temperature sensors, can take over alternative functions: Firmware /TEMP12 The /TEMP12 firmware allows you to connect up to twelve digital temperature sensors (type Dallas DS18B20). Data from twelve channels is transferred to your PC via USB. ONE temperature

More information

Liquid Level Sensors. M-Series Magnetostrictive Sensors

Liquid Level Sensors. M-Series Magnetostrictive Sensors Liquid Level Sensors M-Series Magnetostrictive Sensors Model USTD II Underground Storage Tank Level Sensor For Leak Detection and Inventory Monitoring 550980 C Installation Instructions Table of Contents:

More information

Fanuc Serial (RS232) Communications Information

Fanuc Serial (RS232) Communications Information Memex Automation Inc. 777 Walkers Line, Burlington, Ontario Canada L7N 2G1 Fanuc Serial (RS232) Communications Information Contents Signal Description Fanuc Serial Cable Information Timing Chart When The

More information

Product Specification for model TT Transducer Tester Rev. B

Product Specification for model TT Transducer Tester Rev. B TT Rev B April 20, 2010 Product Specification for model TT Transducer Tester Rev. B The Rapid Controls model TT Rev B transducer tester connects to multiple types of transducers and displays position and

More information

Shenzhen ATC Technology CO.,LTD ATC. A-1 Serial Remote I/O Module. User Manual. V1.13 Edit:2018/01/

Shenzhen ATC Technology CO.,LTD ATC. A-1 Serial Remote I/O Module. User Manual. V1.13 Edit:2018/01/ ATC A-1 Serial Remote I/O Module User Manual V1.13 Edit:2018/01/30-1 - Catalogue 1.The introduction of Modbus protocol...- 3-1.1 Modbus protocol master-slave response process... - 3-1.2 Modbus register

More information

Datataker Manual. User s Manual. A Concise Reference for Datataker Models DT50 DT500, DT600 DT505, DT605 DT515, DT615 and the Channel Expansion Module

Datataker Manual. User s Manual. A Concise Reference for Datataker Models DT50 DT500, DT600 DT505, DT605 DT515, DT615 and the Channel Expansion Module User s Manual Datataker Manual A Ccise eference for Datataker Models DT0 DT00, DT00 DT0, DT0 DT, DT and the Channel Expansi Module Series EUOPE This product complies with the requirements of European Directives

More information

Installation, Operation and Maintenance Manual

Installation, Operation and Maintenance Manual M518 Rev. B Model 1030F Indicator-Totalizer Model 1030F Indicator-Totalizer Installation, Operation and Maintenance Manual Table of Contents General... 1 Installation... 1 Operation... 7 Programming...

More information

Protocol and instruction set for remote control via the infrared interface. Table of Contents

Protocol and instruction set for remote control via the infrared interface. Table of Contents Application information 7 HD mini20 HD 3000 Series HD 4000 Series Protocol and instruction set for remote control via the infrared interface Table of Contents 1 Technical Principles...2 2 Protocol...2

More information

DA 22 Technical Specification

DA 22 Technical Specification 1/26 DA 22 DA 22-12-2615 DA 22-12-4112 DA 22-30-2630 DA 22-30-4128 2/26 Content 1. General Description... 3 2. Operating Data... 4 2.1. Operating Data 12V-Versions... 4 2.2. Operating Data 28V-Versions...

More information

Safety for men and machines. DNDS Modular. Product information

Safety for men and machines. DNDS Modular. Product information Safety for men and machines DNDS Modular Product informati DNDS Modular Safety category DlNA Elektrik GmbH Esslinger Straße D - 79 Wolfschlugen Tel. 009 70/9 7-0 Fax 009 70/9 7- www.dinaelektrik.de info@dinaelektrik.de

More information

MXD70 Series. Multi-parameter Monitor. Modbus RS485 Interface Operating Guide

MXD70 Series. Multi-parameter Monitor. Modbus RS485 Interface Operating Guide MXD70 Series Multi-parameter Monitor Preface Preface Product warranty The MXD70 Series has a warranty against defects in materials and workmanship for three years from the date of shipment. During this

More information

Installation Manual. ZON-0500 Version 1.20 ZON HBX Control Systems Inc.

Installation Manual. ZON-0500 Version 1.20 ZON HBX Control Systems Inc. Installati Manual ZON-000 Versi.0 ZON-000 HBX Ctrol Systems Inc. HBX ZON-000 Ze Ctrol Versi.0 Notes: Ze-000 Manual Page HBX ZON-000 Ze Ctrol Versi.0 HBX ZON-000 ZONE MODULE Introducti The ZON-000 is an

More information

WSC-1000 TM WELD SEQUENCE CONTROLLER. Operation / Installation Manual. Computer Weld Technology, Inc.

WSC-1000 TM WELD SEQUENCE CONTROLLER. Operation / Installation Manual. Computer Weld Technology, Inc. Computer Weld Technology, Inc. 10702 Old Bammel N Houston Rd. Houston, TX 77086 Phone: (713) 462-2118 Fax: (713) 462-2503 Email: cwt@cweldtech.com WSC-1000 TM WELD SEQUENCE CONTROLLER Operation / Installation

More information

SCM-800-PELCO. EIGHT INPUT CODE MERGER for PELCO RS-422 CAMERA CONTROL CODE.

SCM-800-PELCO. EIGHT INPUT CODE MERGER for PELCO RS-422 CAMERA CONTROL CODE. SCM-800-PELCO EIGHT INPUT CODE MERGER for PELCO RS-422 CAMERA CONTROL CODE www.sennetech.net Sennetech, Inc. 6455 W. Bath Rd. Perry, MI 48872 U.S.A. Ph (517) 675-1150 Fax(517) 675-1151 1 SCM-800-Pelco

More information

Data Acquisition Modules/ Distributed IO Modules

Data Acquisition Modules/ Distributed IO Modules User Manual Data Acquisition Modules/ Distributed IO Modules Future Design Controls, Inc. 7524 West 98 th Place / P.O. Box 1196 Bridgeview, IL 60455 888.751.5444 - Office: 888.307.8014 - Fax 866.342.5332

More information

INCLINOMETER RS232 SWITCH

INCLINOMETER RS232 SWITCH Main Features - Two axis digital inclinometer - Angle measurement range of +/-5, +/-15 and +/-30, Resolution up to 0.001 - Interface: RS232, Code: ASCII, Switch Open Collector - Housing: 70 mm Programmable

More information

The LEBOW 7554 Operator's Manual 7.2

The LEBOW 7554 Operator's Manual 7.2 The LEBOW 7554 Operator's Manual 7.2 This manual covers operating version 7.2 of the LEBOW 7554. 11 February 1999 Lebow Products Inc Lebow Products Inc 1728 Maplelawn Rd Troy, MI 48084 1 (800) 803-1164

More information

Condumax W CLS15 and CLS15D

Condumax W CLS15 and CLS15D Technical Information Condumax W CLS15 and CLS15D Conductivity sensors, analog or digital with Memosens technology, Cell constant k = 0.01 cm -1 or k = 0.1 cm -1 Application Measurement in pure and ultrapure

More information

LC-10 Chipless TagReader v 2.0 August 2006

LC-10 Chipless TagReader v 2.0 August 2006 LC-10 Chipless TagReader v 2.0 August 2006 The LC-10 is a portable instrument that connects to the USB port of any computer. The LC-10 operates in the frequency range of 1-50 MHz, and is designed to detect

More information

Optical laser distance sensors. Dimensioned drawing

Optical laser distance sensors. Dimensioned drawing Dimensioned drawing en 02-2012/11 50118552 50 100mm 18-30 V DC We reserve the right to make changes DS_ODSL9L100_en_50118552.fm High resolution 0.01mm Reflection-independent distance information Highly

More information

2554 n n n n n n n n n n n n n n. Captive External. E2554 n n n n n n n

2554 n n n n n n n n n n n n n n. Captive External. E2554 n n n n n n n HAYD: 03 756 744 G4 5000 Series: Ø 5 mm (.0-in) Can-Stack Stepper Motor Linear Actuator Haydon 5000 Series generates higher force than all other competitors. Offers high durability and exceptional performance.

More information

User Manual EnOcean V 0.1

User Manual EnOcean V 0.1 & User Manual EnOcean V 0.1 Last update: July 2012 All software-related descriptions refer to the software V1279. We recommend to update older versions of the system. Small deviations in the description

More information

ioselect Z-NET Z-4RTD 4 Channel RTD Input Module

ioselect Z-NET Z-4RTD 4 Channel RTD Input Module 4 Channel nput Module : PT00, PT000, PT500 & N00: 2, 3 & 4 wire 500 V solation, 6-way Modbus Communications Adjustable Sampling Time Accuracy to 0.2 C Configuration and Setup Software EC 63 Flexible Power

More information

RTM Baud Radio Data Modem

RTM Baud Radio Data Modem OED Electronics Pty. Ltd. ABN 16 064 869 594 Phone (07) 3207 1023 Int. +61 7 3207 1023 Fax (07) 3822 6102 E-Mail oed @ powerup.com.au RTM 2410 2400 Baud Radio Data Modem For Tait 2010, 2015 and "Data"

More information

DEVICE CONFIGURATION INSTRUCTIONS. WinFrog Device Group:

DEVICE CONFIGURATION INSTRUCTIONS. WinFrog Device Group: WinFrog Device Group: Device Name/Model: Device Manufacturer: Device Data String(s) Output to WinFrog: WinFrog Data String(s) Output to Device: WinFrog Data Item(s) and their RAW record: GPS NMEA GPS (Sercel)

More information

Mastr III P25 Base Station Transmitter Tune-up Procedure

Mastr III P25 Base Station Transmitter Tune-up Procedure Mastr III P25 Base Station Transmitter Tune-up Procedure 1. Overview The Mastr III Base Station transmitter alignment is performed in several steps. First, the Transmit Synthesizer module is aligned to

More information

DSTS-5A/2C User's Manual

DSTS-5A/2C User's Manual ELECTRONIC DEVICES INC. P.O. BOX 15037, CHESAPEAKE, VA 23328. PH 757-421-2968 FAX 421-0518 DSTS-5A/2C User's Manual 1. PACKING LIST 2. OVERVIEW 3. CONNECTING THE DSTS-5A/2C TO A COMPUTER 4. CONNECTING

More information

Operating manual handylab multi 12 g/l ARng ph/dissolved Oxygen/Conductivity Measuring Instrument

Operating manual handylab multi 12 g/l ARng ph/dissolved Oxygen/Conductivity Measuring Instrument Operating manual ba75371e handylab multi 12 O 7 9 2 M 1 7 6 ARng C TP mg/l STO CAL O AR ph/dissolved Oxygen/Conductivity Measuring Instrument ba75371e01 11/2002 Accuracy when going to press The use of

More information

ASONIK POLAND, PL Tuczno, str. Sloneczna 6. Tel./Fax. (061)

ASONIK POLAND, PL Tuczno, str. Sloneczna 6. Tel./Fax. (061) ASONIK POLAND, PL-62007 Tuczno, str. Sloneczna 6. Tel./Fax. (061) 815-6261 http://www.asonik.eu e-mail: asonik@sylaba.poznan.pl Smart Magnetic Sensor Type SMS-102 Probes for Transverse magnetic fields

More information

INTRODUCTION. T hank you for your HB8215/HB8216 loadcell indicator purchase. The HB8215 and HB8216 are the best choice for industrial weighing

INTRODUCTION. T hank you for your HB8215/HB8216 loadcell indicator purchase. The HB8215 and HB8216 are the best choice for industrial weighing INTRODUCTION T hank you for your HB8215/HB8216 loadcell indicator purchase. The HB8215 and HB8216 are the best choice for industrial weighing application requiring quality, performance and economy. Please

More information

OPERATING INSTRUCTIONS AND SYSTEM DESCRIPTION FOR THE TEC-B-01M VOLTAGE CLAMP MODULE FOR EPMS SYSTEMS. VERSION 1.2 npi 2014

OPERATING INSTRUCTIONS AND SYSTEM DESCRIPTION FOR THE TEC-B-01M VOLTAGE CLAMP MODULE FOR EPMS SYSTEMS. VERSION 1.2 npi 2014 OPERATING INSTRUCTIONS AND SYSTEM DESCRIPTION FOR THE TEC-B-01M VOLTAGE CLAMP MODULE FOR EPMS SYSTEMS VERSION 1.2 npi 2014 npi electronic GmbH, Bauhofring 16, D-71732 Tamm, Germany Phone +49 (0)7141-9730230;

More information

Operating Instructions

Operating Instructions TG 310CS Coin Counting - and Sorting Machine Operating Instructions Total Postweigh International Ltd. 1 Skelgillside Alston, Cumbria CA9 3TR Telephone: 01434 381182 Facsimile: 01434 382035 www.postweigh.com

More information

DDS-PLL SYNTHESIZER DPL-2.5GF USER S MANUAL DIGITAL SIGNAL TECHNOLOGY, INC.

DDS-PLL SYNTHESIZER DPL-2.5GF USER S MANUAL DIGITAL SIGNAL TECHNOLOGY, INC. DDS-PLL SYNTHESIZER DPL-2.5GF USER S MANUAL DIGITAL SIGNAL TECHNOLOGY, INC. 1-7-3, HIGASHI BENZAI, ASAKA CITY SAITAMA 351-22 JAPAN TEL : 81-48-468-694 FAX : 81-48-468-621 http://www.dst.co.jp/en 1 DPL-2.5GF

More information

Analog Module D1-15P User Manual

Analog Module D1-15P User Manual D1-15P Manual Analog Module D1-15P User Manual Sielco Elettronica Srl Edison Street 209 20019 Settimo Milanese (MI) - Italy http://www.sielcoelettronica.com info @ sielcoelettronica.com Tel 02 48916252

More information