1 МЕДТЕХНИКА-СТОЛИЦА (495) (495) , г. Москва, Дмитровское ш. 85

2 ATLAS Corneal Topography Product Overview Model 9000

3 ATLAS Model 9000 Overview Next-generation corneal topography system Small footprint, self-contained, no external PC required Modern Windows XP platform Highly accurate Proven Placido disk technology, found in more than 5,000 ATLAS systems worldwide Patented surface reconstruction Easy to use Delegate topography to staff Reproducible results independent of operator technique

4 ATLAS Placido Disk Technology Ideal Placido disk design means reliable results for a wide range of patients Large diameter, closely spaced rings minimizes ring jam found in smallcone systems Optimized for the range of corneas expected in clinical practice Superior alignment through triangulation with patented Cone-of- Focus Removes axial positioning uncertainty Enables automatic correction of operator focus and positioning error

5 Accuracy via the Arc-Step Method Arc-Step Method Throws a net over cornea, reconstructing cornea where net intersects itself Ensures accurate transition from ring to ring Minimal residual error Only the ATLAS performs multiple iterations of triangulation (the Van Saarloos Variant) to minimize any residual error

6 Designed for Practitioner and Patient Easy to use Long working distance (70 mm) is less sensitive to alignment error Comfortable for the patient Does not enter patient s orbit Non-visible infrared (IR) ring illumination for increased patient comfort and corneal coverage Unique chinrest positions patient for wide peripheral coverage and automatically detects OD/OS

7 Model 9000 Key Enhancements SmartCapture Technology Pupillometry at 2 levels of illumination HVID (white to white) measurement Corneal wavefront analysis Mean curvature analysis Customizable to user preferences

8 SmartCapture Technology Analyzes 15 digital images/sec. during alignment Automatically selects best image Improved image processing provides more repeatable, reliable results Less dependence on operator technique means greater efficiency and fewer repeat exams

9 Pupillometry and HVID Measurement Understand pupil size changes in different light conditions: Scotopic (no light) Photopic (700 nm) Simplify contact lens selection with automatic Horizontal Visible Iris Diameter (HVID, or white to white ) measurement

10 Standard Views/Maps Axial Curvature Tangential Curvature Simulated Keratometry Videokeratoscopic Refractive Power Mean Curvature

11 Standard Views/Maps (cont.) Elevation (Best-Fit Sphere) Irregularity (Best-Fit Ellipsoid) Corneal Wavefront Image Simulations, Point Spread Function Modulation Transfer Function Zernike Analysis

12 Standard Displays Single View Overview OD/OS Compare Trend with Time Difference Custom

13 Clinical Applications of ATLAS Corneal Topography

14 Detect and Manage Pathology Axial map reveals a displaced corneal apex and inferior steepening, which standard keratometry at 3 mm would have missed. Irregularity map, relative to a best-fit ellipsoid, highlights surface irregularities that may limit bestspectacle corrected visual acuity. Elevation map shows a 29 micron protrusion above a best-fit reference sphere. Mean Curvature map eliminates corneal astigmatism, highlighting underlying features, such as this cone peak.

15 Track Corneal Health for Improved Care Axial map reveals inferior steepening and corneal warpage from years of wearing an improperly fit RGP contact lens with a highly aspheric back surface. The cornea was allowed to normalize over approximately 4 months and returned to a normal appearing astigmatic shape. Image simulation displays higher-order corneal aberrations and confirms patient s complaints of severe spectacle blur. Image simulation shows the improvement in visual acuity with a reduction in higher-order aberrations.

16 Assess Higher-Order Aberrations with Corneal Wavefront Analysis Visualize corneal aberrations such as coma, trefoil, and spherical aberration Educate patients about higher-order aberrations, which may limit best spectacle-corrected visual acuity Assess retinal image with: Image Simulation Point Spread Function Modulation Transfer Function

17 Optimize Aspheric IOL Selection Calculate corneal spherical aberration Z(4,0) for optimizing aspheric IOL selection Understand changes in corneal aberrations with varying pupil size to simulate scotopic, photopic, and mesopic lighting conditions

18 Future Optional Software Modules PathFinder II Corneal Analysis - Next-generation screening tool for detection of keratoconus and other corneal conditions, based on a comprehensive normative database MasterFit II Contact Lens - Simplify the fitting of RGP lenses and minimize chair time with this advanced contact lens fitting software ATLAS Review Software - Same functionality as ATLAS 9000 software, except for image acquisition or editing. - Compatible with data from ATLAS 993/995 topographers EMR Export - Automatically export exams to your EMR Not Available for Sale

ATLAS Corneal Topography System

ATLAS Corneal Topography System ATLAS Corneal Topography System Simply accurate for maximum productivity Model 9000 The New ATLAS Take your practice to the next level Carl Zeiss Meditec has taken the world s leading corneal topography

More information

Refractive Power / Corneal Analyzer. OPD-Scan III

Refractive Power / Corneal Analyzer. OPD-Scan III Refractive Power / Corneal Analyzer OPD-Scan III Comprehensive Vision Analysis and NIDEK, a global leader in ophthalmic and optometric equipment, has created the OPD-Scan III, the third generation aberrometer

More information

Wave Front Topography. ReSeeVit Evolution Topography Module for Modi Topographer

Wave Front Topography. ReSeeVit Evolution Topography Module for Modi Topographer Wave Front Topography ReSeeVit Evolution Topography Module for Modi Topographer Introduction The aberrations in the central optical zone have a greater effect than those closer to the edge. From an optical

More information

Página 1 de 9 TopPage > Eye Care > Diagnostic > Wave-Front Analyzer KR-1W Wave-Front Analyzer KR-1W Perfection for Professionals : KR-1W Topcon, with its wealth of experience in designing and manufacturing

More information

OCULUS Easygraph. Topographer. We focus on progress

OCULUS Easygraph. Topographer. We focus on progress OCULUS Easygraph Topographer We focus on progress The Compact Corneal Topographer at a Glance Corneal topographer with built-in keratometer Comfortable, hygienic working distance reduces the influence

More information

The Aberration Structure of the Keratoconic Eye

The Aberration Structure of the Keratoconic Eye The Aberration Structure of the Keratoconic Eye Geunyoung Yoon, Ph.D. Department of Ophthalmology Center for Visual Science Institute of Optics Department of Biomedical Engineering University of Rochester

More information

Sirius TOMOGRAPH AND CORNEAL TOPOGRAPHER

Sirius TOMOGRAPH AND CORNEAL TOPOGRAPHER Sirius TOMOGRAPH AND CORNEAL TOPOGRAPHER EN Sirius TOMOGRAPH AND CORNEAL TOPOGRAPHER Combines placido disk topography with Sheimpflug tomography of the anterior segment. Sirius provides information on

More information

OCULUS Keratograph 4. Topographer. We focus on progress

OCULUS Keratograph 4. Topographer. We focus on progress OCULUS Keratograph 4 Topographer We focus on progress Ophthalmologist Versatile and precise For me the Keratograph 4 is an indispensable device for diagnosis and surgical planning. Its automatic measurement

More information

OCULUS Easygraph. So Small and Yet a Topographer. Small, but Efficient As a Big One. All Important Parameters at a Glance

OCULUS Easygraph. So Small and Yet a Topographer. Small, but Efficient As a Big One. All Important Parameters at a Glance OCULUS Easygraph So Small and Yet a Topographer Small, but Efficient As a Big One Wanting to work with a video keratometer in spite of limited space? Then the OCULUS Easygraph is what you re looking for.

More information

Optical Path Difference Scanning System OPD-Scan II ARK-10000

Optical Path Difference Scanning System OPD-Scan II ARK-10000 Optical Path Difference Scanning System OPD-Scan II ARK-10000 Optical Path Difference Scanning System OPD-Scan II ARK-10000 Accurate and Reliable Data for Optic Diagnostics The OPD-Scan II provides information

More information

THE BEST OF BOTH WORLDS Dual-Scheimpflug and Placido Reaching a new level in refractive screening

THE BEST OF BOTH WORLDS Dual-Scheimpflug and Placido Reaching a new level in refractive screening THE BEST OF BOTH WORLDS Dual-Scheimpflug and Placido Reaching a new level in refractive screening Clinical Applications Corneal Implant Planning The comes with a licensable corneal inlay software module

More information

Optical Connection, Inc. and Ophthonix, Inc.

Optical Connection, Inc. and Ophthonix, Inc. Optical Connection, Inc. and Ophthonix, Inc. Partners in the delivery of nonsurgical vision optimization www.opticonnection.com www.ophthonix.com The human eye has optical imperfections that can not be

More information

10/25/2017. Financial Disclosures. Do your patients complain of? Are you frustrated by remake after remake? What is wavefront error (WFE)?

10/25/2017. Financial Disclosures. Do your patients complain of? Are you frustrated by remake after remake? What is wavefront error (WFE)? Wavefront-Guided Optics in Clinic: Financial Disclosures The New Frontier November 4, 2017 Matthew J. Kauffman, OD, FAAO, FSLS STAPLE Program Soft Toric and Presbyopic Lens Education Gas Permeable Lens

More information

ClearKone Restoring vision. Changing lives.

ClearKone Restoring vision. Changing lives. ClearKone Restoring vision. Changing lives. For additional information on fitting ClearKone, please visit www.fitsynergeyes.com to view fitting videos, case studies, NaFL pictures and more. FITTING GUIDE

More information

What is Wavefront Aberration? Custom Contact Lenses For Vision Improvement Are They Feasible In A Disposable World?

What is Wavefront Aberration? Custom Contact Lenses For Vision Improvement Are They Feasible In A Disposable World? Custom Contact Lenses For Vision Improvement Are They Feasible In A Disposable World? Ian Cox, BOptom, PhD, FAAO Distinguished Research Fellow Bausch & Lomb, Rochester, NY Acknowledgements Center for Visual

More information

KERATOCONUS. In the most advances cases, the corneal deformation can be easy observed fig. 1. Fig. 1

KERATOCONUS. In the most advances cases, the corneal deformation can be easy observed fig. 1. Fig. 1 Mario Giovanzana Milano, 14 nd october 01 KERATOCONUS INTRODUCTION The keratocunus is a deformation of the cornea that tends to assume the shape of a cono. The genesis is substantially uncertain. It is

More information

An Interesting Use of Bausch and Lomb s KeraSoft IC Lens

An Interesting Use of Bausch and Lomb s KeraSoft IC Lens An Interesting Use of Bausch and Lomb s KeraSoft IC Lens Nate Schlotthauer, OD 2012 Michigan College of Optometry Cornea and Contact Lens Resident Introduction: The KeraSoft IC lens, introduced to the

More information

Wave-Front Analyzer KR-1W

Wave-Front Analyzer KR-1W Wave-Front Analyzer Perfection for Professionals: Topcon, with its wealth of experience in designing and manufacturing refractometers and other diagnostic equipment for over 50 years, introduces a new

More information

FITTING GUIDE PRACTITIONER S ROSE K2 KC ROSE K2 NC ROSE K2 IC ROSE K2 PG NIPPLE CONE IRREGULAR CORNEA POST GRAFT

FITTING GUIDE PRACTITIONER S ROSE K2 KC ROSE K2 NC ROSE K2 IC ROSE K2 PG NIPPLE CONE IRREGULAR CORNEA POST GRAFT Keratoconus Nipple Cone Irregular Cornea Post Graft PRACTITIONER S FITTING GUIDE NIPPLE CONE IRREGULAR CORNEA POST GRAFT Four lens designs... One simple systematic approach to fitting Featuring Easy-to-fit

More information

DesiGneD and ManUFaCTUreD in italy The sharpest vision.

DesiGneD and ManUFaCTUreD in italy The sharpest vision. The sharpest vision. DESIGNED AND MANUFACTURED in ItalY 2 A complete diagnostic station used in clinical practice and research to analyze the optical environment of ocular aberration. Its functions are:

More information

Aberrometry in Clinical Practice

Aberrometry in Clinical Practice Aberrometry in Clinical Practice Aravind Roy, M.S L V Prasad Eye Institute KVC Campus, Vijayawada, India No financial disclosures No conflicts of interest What is your position? Poll Question 1 1. Ophthalmologist

More information

THE SHARPEST VISION. DESIGNED AND MANUFACTURED IN ITALY

THE SHARPEST VISION. DESIGNED AND MANUFACTURED IN ITALY THE SHARPEST VISION. DESIGNED AND MANUFACTURED IN ITALY 2 A complete diagnostic station used in clinical practice and research to analyze the optical environment of ocular aberration. Its functions are:

More information

OCULUS Keratograph 5M Topographer

OCULUS Keratograph 5M Topographer OCULUS Keratograph 5M Topographer OCULUS Keratograph 5M Topographer The multi-purpose topographer has become an integral part of the ophthalmology and optometry practices. User independent measurements

More information

Ron Liu OPTI521-Introductory Optomechanical Engineering December 7, 2009

Ron Liu OPTI521-Introductory Optomechanical Engineering December 7, 2009 Synopsis of METHOD AND APPARATUS FOR IMPROVING VISION AND THE RESOLUTION OF RETINAL IMAGES by David R. Williams and Junzhong Liang from the US Patent Number: 5,777,719 issued in July 7, 1998 Ron Liu OPTI521-Introductory

More information

Soft CL Multifocals Design and Fitting. Soft Multifocal Lens Designs. Issues Surrounding Multifocals. Blur Interpretation. Simultaneous Vision Designs

Soft CL Multifocals Design and Fitting. Soft Multifocal Lens Designs. Issues Surrounding Multifocals. Blur Interpretation. Simultaneous Vision Designs Soft CL Multifocals Design and Fitting Mark Andre, FAAO Associate Professor of Optometry Pacific University Mark Andre, FAAO is affiliated with CooperVision, as a consultant. Issues Surrounding Multifocals

More information

INSTRUCTIONS FOR USE CORNEAL ANALYZER CA-800 CORNEAL ANALYZER

INSTRUCTIONS FOR USE CORNEAL ANALYZER CA-800 CORNEAL ANALYZER INSTRUCTIONS FOR USE CORNEAL ANALYZER CA-800 CORNEAL ANALYZER 0123 REV. 10 2015 Thank you for choosing this product. Please read the information in this manual carefully. You must be knowledgeable with

More information

Principles and clinical applications of ray-tracing aberrometry (Part II)

Principles and clinical applications of ray-tracing aberrometry (Part II) UPDATE/REVIEW Principles and clinical applications of ray-tracing aberrometry (Part II) Alfredo Castillo Gómez, MD, PhD 1 ; Antonio Verdejo del Rey, OD 2 ; Carlos Palomino Bautista, MD 3 ; Ana Escalada

More information

The War against Corneal Warpage

The War against Corneal Warpage Page 1 of 5 I-site Amsterdam Netherlands i-site@netherlens.com Home Archive April 2010 Downloads The War against Corneal Warpage Key words: Corneal Warpage, Corneal Topography, Soft Lens Fit, (R)GP lens

More information

ULTRA-THIN CUSTOM CONTACT LENS FOR KERATOCONUS AND IRREGULAR CORNEAS

ULTRA-THIN CUSTOM CONTACT LENS FOR KERATOCONUS AND IRREGULAR CORNEAS ULTRA-THIN CUSTOM CONTACT LENS FOR KERATOCONUS AND IRREGULAR CORNEAS FITTING SET PARAMETERS The Standard Fitting Set is available with 8 x 14.50mm diameter lenses comprising: 6 x STD periphery Base Curve

More information

Trouble Shooting Guide for Ortho-K lenses

Trouble Shooting Guide for Ortho-K lenses Trouble Shooting Guide for Ortho-K lenses The basic design of the third generation e Lens for Orthokeratology 1. Optic Zone (Base curve, Compression zone, BC) width 5.6 to 6.4mm 2. Fitting curve (second

More information

Optics of Wavefront. Austin Roorda, Ph.D. University of Houston College of Optometry

Optics of Wavefront. Austin Roorda, Ph.D. University of Houston College of Optometry Optics of Wavefront Austin Roorda, Ph.D. University of Houston College of Optometry Geometrical Optics Relationships between pupil size, refractive error and blur Optics of the eye: Depth of Focus 2 mm

More information

Paragon CRT Dual Axis Quick Reference Guide

Paragon CRT Dual Axis Quick Reference Guide Paragon CRT Dual Axis Quick Reference Guide DUAL CRT AXIS PARAGON CRT DUAL AXIS OPTIONS TO COMPENSATE FOR PERIPHERAL CORNEAL ELEVATION DIFFERENCES Most eyes with corneal astigmatism manifest a significant

More information

REF KERATRON. The Standard in Corneal Topography

REF KERATRON. The Standard in Corneal Topography Keratron REF 161104 The Standard in Corneal Topography The first topography unit to accurately represent the local curvature calculated by an Arc-Step method. Because of its outstanding precision, test

More information

The soft approach to RGPs

The soft approach to RGPs CET CONTINUING EDUCATION & TRAINING Sponsored by 1 CET POINT The soft approach to RGPs Part 3: don t let torics put you in a spin 46 Mark Tomlinson BSc (Hons), MCOptom, FBDO (Hons) Most practitioners acknowledge

More information

Keratoconus contact lenses

Keratoconus contact lenses Indic ations All Keratoconus. Daily wear. Recommended replacement: < 2 years. Design Aberration control aspheric optics providing outstanding acuity, reduced flare and glare. Unique design that changes

More information

Irregular Cornea. ROSE K2 Soft TM. Practitioner s Fitting Guide

Irregular Cornea. ROSE K2 Soft TM. Practitioner s Fitting Guide Irregular Cornea ROSE K2 Soft TM Practitioner s Fitting Guide ROSE K2 Soft Applications Design ROSE K2 Soft is a daily wear soft lens for irregular corneas. ROSE K2 Soft is a 3 month replacement lens when

More information

FITTING GUIDE. Duette Hybrid Contact Lenses Duette Progressive Hybrid Contact Lenses - Center Distance - Center Near

FITTING GUIDE. Duette Hybrid Contact Lenses Duette Progressive Hybrid Contact Lenses - Center Distance - Center Near FITTING GUIDE Duette Hybrid Contact Lenses Duette Progressive Hybrid Contact Lenses - Center Distance - Center Near P R O G R E S S I V E The unique advanced-technology Duette hybrid contact lenses are

More information

ULTRA-THIN SPECIALIST CONTACT LENS FOR KERATOCONUS AND IRREGULAR CORNEAS

ULTRA-THIN SPECIALIST CONTACT LENS FOR KERATOCONUS AND IRREGULAR CORNEAS ULTRA-THIN SPECIALIST CONTACT LENS FOR KERATOCONUS AND IRREGULAR CORNEAS DIAMETER & PERIPHERY GUIDE KeraSoft Thin s increased flexibility improves drapage over the peripheral cornea. This reduces the need

More information

Introduces The OK -EX -Total Tear Layer Control- Features. What is the OK-EX? Multi-Axis Toric Option.

Introduces The OK -EX -Total Tear Layer Control- Features. What is the OK-EX? Multi-Axis Toric Option. Features Optimum Control and Results for High Myopia Hyperbolic Treatment Zones for Maximum Flattening Dual Aspheric Reverse and Alignment Zones for Improved Lens Centering Topographical / Empirical /

More information

CA-800 Corneal Analyzer

CA-800 Corneal Analyzer CA-800 Corneal Analyzer CA-800 - Fully featured Ease of use The CA-800 is extremely easy to handle and use. From image acquisition to analysis, the on-board software is intuitive and user-friendly and

More information

CA-800 Corneal Analyzer

CA-800 Corneal Analyzer CA-800 Corneal Analyzer CA-800 - Fully featured CA-800 - Corneal Analyzer Ease of use The CA-800 is extremely easy to handle and use. From image acquisition to analysis, the on-board software is intuitive

More information

The Impact of New Generation Aspherical Soft Contact Lenses on Quality of Vision: A Comparison with Spherical Contact Lenses and Spectacle Correction

The Impact of New Generation Aspherical Soft Contact Lenses on Quality of Vision: A Comparison with Spherical Contact Lenses and Spectacle Correction Deniz Oral, Maryo C. Kohen, Melda Yenerel, Ebru Gorgun, Sule Ziylan, Ferda Ciftci Yeditepe University Faculty of Medicine, Department of Ophthalmology, Istanbul Introduction The correction of higher order

More information

Fitting Manual Use with kerasofttraining.com

Fitting Manual Use with kerasofttraining.com Fitting Manual Use with Fitting Manual: Contents This fitting manual is best used in conjunction with KeraSoft IC online training. To register, please visit www. 01 Kerasoft IC Design - Outlines the KeraSoft

More information

Crystalens AO: Accommodating, Aberration-Free, Aspheric Y. Ralph Chu, MD Chu Vision Institute Bloomington, MN

Crystalens AO: Accommodating, Aberration-Free, Aspheric Y. Ralph Chu, MD Chu Vision Institute Bloomington, MN Crystalens AO: Accommodating, Aberration-Free, Aspheric Y. Ralph Chu, MD Chu Vision Institute Bloomington, MN Financial Disclosure Advanced Medical Optics Allergan Bausch & Lomb PowerVision Revision Optics

More information

Aberrations Before and After Implantation of an Aspheric IOL

Aberrations Before and After Implantation of an Aspheric IOL Ocular High Order Aberrations Before and After Implantation of an Aspheric IOL Fabrizio I. Camesasca, MD Massimo Vitali, Orthoptist Milan, Italy I have no financial interest to disclose Wavefront Measurement

More information

Technicians & Nurses Program

Technicians & Nurses Program ASCRS ASOA Symposium & Congress Technicians & Nurses Program April 17-21, 2015 San Diego, California What Do All These Colors Mean And who s paying for all the ink? BLUF: Red is bad. Frank W. Scribbick,

More information

4/2/2015. Bonnie An Henderson MD Clinical Professor of Ophthalmology Tufts University School of Medicine Ophthalmic Consultants of Boston

4/2/2015. Bonnie An Henderson MD Clinical Professor of Ophthalmology Tufts University School of Medicine Ophthalmic Consultants of Boston Imaging Modalities That Help Maximize Uncorrected Visual Outcomes After Cataract Surgery Dr.BonnieAn Henderson, MD Dr. Kalpana Narendran, DNB Dr.Prabhu vijayaraghavan, M.S, FICO Dr. Sandra Chandramouli,DNB

More information

OCULUS Keratograph 5M Topographer

OCULUS Keratograph 5M Topographer OCULUS Keratograph 5M Topographer OCULUS Keratograph 5M Topographer The multi-purpose topographer has become an integral part of the ophthalmological and optometric practice. Examiner-independent measurements

More information

INSTRUCTION MANUAL WAVE-FRONT ANALYZER. KR-1W Viewer. Version TOPCON Corporation

INSTRUCTION MANUAL WAVE-FRONT ANALYZER. KR-1W Viewer. Version TOPCON Corporation INSTRUCTION MANUAL WAVE-FRONT ANALYZER KR-1W Viewer Version 1.01 TOPCON Corporation December 15, 2009 INTRODUCTION Thank you for purchasing the TOPCON Wave-front Analyzer KR-1W Viewer. The KR-1W Viewer

More information

The Dysphotopsia Mystery. John J. Bussa, M.D.

The Dysphotopsia Mystery. John J. Bussa, M.D. The Dysphotopsia Mystery John J. Bussa, M.D. Cataract Surgery Cataract Surgery Desirable Traits Foldable Lens Inert (non reactive) with a memory Thin folds tight and goes through a smaller incision

More information

PROCEEDINGS OF SPIE. Measurement of low-order aberrations with an autostigmatic microscope

PROCEEDINGS OF SPIE. Measurement of low-order aberrations with an autostigmatic microscope PROCEEDINGS OF SPIE SPIEDigitalLibrary.org/conference-proceedings-of-spie Measurement of low-order aberrations with an autostigmatic microscope William P. Kuhn Measurement of low-order aberrations with

More information

Wavefront-Guided Programmable Spectacles Related Metrics

Wavefront-Guided Programmable Spectacles Related Metrics Wavefront-Guided Programmable Spectacles Related Metrics Lawrence Sverdrup, Sean Sigarlaki, Jeffrey Chomyn, Jagdish Jethmalani, Andreas Dreher Ophthonix, Inc. 23rd February 2007 Outline Background on Ophthonix

More information

Assessing Visual Quality With the Point Spread Function Using the NIDEK OPD-Scan II

Assessing Visual Quality With the Point Spread Function Using the NIDEK OPD-Scan II Assessing Visual Quality With the Point Spread Function Using the NIDEK OPD-Scan II Edoardo A. Ligabue, MD; Cristina Giordano, OD ABSTRACT PURPOSE: To present the use of the point spread function (PSF)

More information

Corneal Asphericity and Retinal Image Quality: A Case Study and Simulations

Corneal Asphericity and Retinal Image Quality: A Case Study and Simulations Corneal Asphericity and Retinal Image Quality: A Case Study and Simulations Seema Somani PhD, Ashley Tuan OD, PhD, and Dimitri Chernyak PhD VISX Incorporated, 3400 Central Express Way, Santa Clara, CA

More information

Corneal Mapping over the Contact Lens. Challenge: Getting the Most out of Soft Contact Lens Multifocals

Corneal Mapping over the Contact Lens. Challenge: Getting the Most out of Soft Contact Lens Multifocals Contact Lens Management of the Challenging Patient Disclosures: Alcon Bausch + Lomb SpecialEyes Valley Contax Vistakon Contact Lens Challenges Matthew J. Lampa, OD, FAAO lampa@pacificu.edu Challenge: Getting

More information

Auto Ref/ Keratometer / Auto Refractometer ARK-1 / AR-1

Auto Ref/ Keratometer / Auto Refractometer ARK-1 / AR-1 Auto Ref/ Keratometer / Auto Refractometer ARK-1 / AR-1 The Superior Auto and Auto What is the superior auto ref / The ARK-1 / AR-1 series speak for themselves, and auto refractometer generating greater

More information

Clinical Update for Presbyopic Lens Options

Clinical Update for Presbyopic Lens Options Clinical Update for Presbyopic Lens Options Gregory D. Searcy, M.D. Erdey Searcy Eye Group Columbus, Ohio The Problem = Spherical Optics Marginal Rays Spherical IOL Light Rays Paraxial Rays Spherical Aberration

More information

Optical Characteristics of Next Generation Dual Optic IOL

Optical Characteristics of Next Generation Dual Optic IOL Optical Characteristics of Next Generation Dual Optic IOL Scott Evans, MD Sanjeev Kasthurirangan, PhD Val Portney, PhD Financial Disclosures Scott Evans is an employee of Abbott Medical Optics Inc. Sanjeev

More information

Using Orthotool Software

Using Orthotool Software Using Orthotool Software OrthoTool 101010 (2008) Original Design with 5 Curves. You can just use the new version 2013 Toric RC, AC & PC only with OT 2008 so far Hyperopic ortho-k GP lens design Aspheric

More information

Subjective Image Quality Metrics from The Wave Aberration

Subjective Image Quality Metrics from The Wave Aberration Subjective Image Quality Metrics from The Wave Aberration David R. Williams William G. Allyn Professor of Medical Optics Center For Visual Science University of Rochester Commercial Relationship: Bausch

More information

OPTICAL SYSTEMS OBJECTIVES

OPTICAL SYSTEMS OBJECTIVES 101 L7 OPTICAL SYSTEMS OBJECTIVES Aims Your aim here should be to acquire a working knowledge of the basic components of optical systems and understand their purpose, function and limitations in terms

More information

NIDEK ADVANCED VISION EXCIMER LASER SYSTEM

NIDEK ADVANCED VISION EXCIMER LASER SYSTEM NIDEK ADVANCED VISION EXCIMER LASER SYSTEM NIDEK ADVANCED VISION EXCIMER LASER SYSTEM Delivering Ultimate Solutions Today NIDEK delivers NAVEX Quest, the evolutionary customized refractive surgery platform.

More information

Technicians & Nurses Program

Technicians & Nurses Program ASCRS ASOA Symposium & Congress Technicians & Nurses Program May 6-10, 2016 New Orleans ADVANCED BIOMETRY AND IOL CALCULATIONS Financial Disclosures No relevant disclosures Karen Bachman, COMT, ROUB The

More information

Lecture 4: Geometrical Optics 2. Optical Systems. Images and Pupils. Rays. Wavefronts. Aberrations. Outline

Lecture 4: Geometrical Optics 2. Optical Systems. Images and Pupils. Rays. Wavefronts. Aberrations. Outline Lecture 4: Geometrical Optics 2 Outline 1 Optical Systems 2 Images and Pupils 3 Rays 4 Wavefronts 5 Aberrations Christoph U. Keller, Leiden University, keller@strw.leidenuniv.nl Lecture 4: Geometrical

More information

Author Contact Information: Erik Gross VISX Incorporated 3400 Central Expressway Santa Clara, CA, 95051

Author Contact Information: Erik Gross VISX Incorporated 3400 Central Expressway Santa Clara, CA, 95051 Author Contact Information: Erik Gross VISX Incorporated 3400 Central Expressway Santa Clara, CA, 95051 Telephone: 408-773-7117 Fax: 408-773-7253 Email: erikg@visx.com Improvements in the Calculation and

More information

Difrotec Product & Services. Ultra high accuracy interferometry & custom optical solutions

Difrotec Product & Services. Ultra high accuracy interferometry & custom optical solutions Difrotec Product & Services Ultra high accuracy interferometry & custom optical solutions Content 1. Overview 2. Interferometer D7 3. Benefits 4. Measurements 5. Specifications 6. Applications 7. Cases

More information

Transferring wavefront measurements to ablation profiles. Michael Mrochen PhD Swiss Federal Institut of Technology, Zurich IROC Zurich

Transferring wavefront measurements to ablation profiles. Michael Mrochen PhD Swiss Federal Institut of Technology, Zurich IROC Zurich Transferring wavefront measurements to ablation profiles Michael Mrochen PhD Swiss Federal Institut of Technology, Zurich IROC Zurich corneal ablation Calculation laser spot positions Centration Calculation

More information

FITTING GUIDE. Applications. Design Options THE CRISP, CLEAR VISUAL ACUITY OF A GP LENS MEETS THE HYDRATING COMFORT OF A SOFT LENS

FITTING GUIDE. Applications. Design Options THE CRISP, CLEAR VISUAL ACUITY OF A GP LENS MEETS THE HYDRATING COMFORT OF A SOFT LENS THE CRISP, CLEAR VISUAL ACUITY OF A GP LENS MEETS THE HYDRATING COMFORT OF A SOFT LENS FITTING GUIDE Applications Design Options NORMAL PROLATE CORNEAS PRESBYOPIA ASTIGMATISM EMERGENT OR FRUSTE KERATOCONUS

More information

OCULUS Pentacam AXL Always an Axial Length Ahead

OCULUS Pentacam AXL Always an Axial Length Ahead OCULUS Pentacam AXL Always an Axial Length Ahead EFFICIENCY AND BETTER WORKFLOW Your Cataract Workstation! The new Pentacam AXL is an alliance of the time-tested Pentacam technology with high-precision

More information

Unique Aberration-Free IOL: A Vision that Patients

Unique Aberration-Free IOL: A Vision that Patients Unique Aberration-Free IOL: A Vision that Patients Can Appreciate An Aspheric Optic for Improved Quality of Vision n Traditional spherical IOLs create Bilateral implantation study spherical aberration

More information

PREMIUM LENSES WITH VARIABLE BASE CURVE

PREMIUM LENSES WITH VARIABLE BASE CURVE PREMIUM LENSES WITH VARIABLE BASE CURVE Inspired by nature - 1 - CONTENT THE ADVANCEMENT OF CAMBER CAMBER TECHNOLOGY Features and Properties Camber Benefits EXPLORING CAMBER LENS SERIES NATURAL NATURAL

More information

DESIGNED FOR SUCCESS...GUARANTEED TO FIT

DESIGNED FOR SUCCESS...GUARANTEED TO FIT This is a supplement to the main Flexlens fitting guide and does not contain all the warnings, precautions and directions for use found in the main fitting guide. Please refer to the main fitting guide

More information

Fitting Manual Use with

Fitting Manual Use with Fitting Manual Use with The KeraSoft IC Lens for and Other Irregular Corneas The KeraSoft IC is a front surface asphere or aspheric toric prism ballasted lens with balanced overall thickness and wavefront

More information

This is the author s version of a work that was submitted/accepted for publication in the following source:

This is the author s version of a work that was submitted/accepted for publication in the following source: This is the author s version of a work that was submitted/accepted for publication in the following source: Atchison, David A. & Mathur, Ankit (2014) Effects of pupil center shift on ocular aberrations.

More information

Auto Ref / Keratometer ARK-560A / 530A / 510A

Auto Ref / Keratometer ARK-560A / 530A / 510A Auto Ref / Keratometer ARK-560A / 530A / 510A Auto Ref/Keratometer ARK-560A / 530A / 510A Excellent Measurement Accuracy Highly Accurate Refractometer The combination of new measuring principle - Pupil

More information

Headline. Pseudophakic Implants, Aspherical Optics, Quality of Vision for Cataract Patients Subline. Damien Gatinel, MD, PhD

Headline. Pseudophakic Implants, Aspherical Optics, Quality of Vision for Cataract Patients Subline. Damien Gatinel, MD, PhD Headline Pseudophakic Implants, Aspherical Optics, Quality of Vision for Cataract Patients Subline Damien Gatinel, MD, PhD Introduction Vision is a complex phenomenon involving a sequence of events that

More information

This is the author s version of a work that was submitted/accepted for publication in the following source:

This is the author s version of a work that was submitted/accepted for publication in the following source: This is the author s version of a work that was submitted/accepted for publication in the following source: Tyagi, Garima, Collins, Michael J., Read, Scott A., & Davis, Brett A. (2012) Corneal changes

More information

Cardinal Points of an Optical System--and Other Basic Facts

Cardinal Points of an Optical System--and Other Basic Facts Cardinal Points of an Optical System--and Other Basic Facts The fundamental feature of any optical system is the aperture stop. Thus, the most fundamental optical system is the pinhole camera. The image

More information

HRK-7000 / HRK-7000A Auto Ref-Keratometer

HRK-7000 / HRK-7000A Auto Ref-Keratometer HRK-7000 / HRK-7000A Auto Ref-Keratometer To measure a human eye with ultra-precision, Huvitz s Wavefront Technology can be the right answer. Human eye is unique as a fingerprint and requires a custom

More information

Maximum Light Transmission. Pupil-independent Light Distribution. 3.75D Near Addition Improved Intermediate Vision

Maximum Light Transmission. Pupil-independent Light Distribution. 3.75D Near Addition Improved Intermediate Vision Multifocal Maximum Light Transmission Pupil-independent Light Distribution Better Visual Quality Increased Contrast Sensitivity 3.75D Near Addition Improved Intermediate Vision Visual Performance After

More information

What s a Corneal GP Lens?

What s a Corneal GP Lens? Slide 1 What s a Corneal GP Lens? Richard Dorer NCLEC Blanchard Contact Lens Inc. 800-367-4009 x 131 richarddorer@gmail.com www.blanchardlab.com Slide 2 Endorsements I am a paid representative and consultant

More information

ERK-9000 Auto Ref/Kertometer

ERK-9000 Auto Ref/Kertometer 1 THE INNOVATIVE DELIVERS PRETESTING DATA YOU CAN COUNT ON. THIS CUTTING-EDGE AUTOREFRACTOR/KERATOMETER GATHERS THE DATA YOU NEED QUICKLY AND ACCURATELY. The integrated seamlessly with the entire Ezer

More information

Evolution of Diffractive Multifocal Intraocular Lenses

Evolution of Diffractive Multifocal Intraocular Lenses Evolution of Diffractive Multifocal Intraocular Lenses Wavefront Congress February 24, 2007 Michael J. Simpson, Ph.D. Alcon Research, Ltd., Fort Worth, Texas Presentation Overview Multifocal IOLs two lens

More information

Design of a Test Bench for Intraocular Lens Optical Characterization

Design of a Test Bench for Intraocular Lens Optical Characterization Journal of Physics: Conference Series Design of a Test Bench for Intraocular Lens Optical Characterization To cite this article: Francisco Alba-Bueno et al 20 J. Phys.: Conf. Ser. 274 0205 View the article

More information

HARD TORIC CONTACT LENSES ASTIGMATISM DEFINITION AND OPTIC BASIS

HARD TORIC CONTACT LENSES ASTIGMATISM DEFINITION AND OPTIC BASIS Mario Giovanzana Milano 20.06.01 HARD TORIC CONTACT LENSES ASTIGMATISM DEFINITION AND OPTIC BASIS An astigmatism, according to Whevell (1817) has been defined as astigmatism or astigmatic ametropia; the

More information

Keratoconus is one of the most leading causes for visual disability

Keratoconus is one of the most leading causes for visual disability ARTICLE A New Fitting Approach for Providing Adequate Comfort and Visual Performance in Keratoconus: Soft HydroCone (Toris K) Lenses Koray Gumus, M.D., FEBOphth. and Nisa Kahraman, M.D. Objective: To evaluate

More information

OPTI-201/202 Geometrical and Instrumental Optics Copyright 2018 John E. Greivenkamp. Section 16. The Eye

OPTI-201/202 Geometrical and Instrumental Optics Copyright 2018 John E. Greivenkamp. Section 16. The Eye 16-1 Section 16 The Eye The Eye Ciliary Muscle Iris Pupil Optical Axis Visual Axis 16-2 Cornea Right Eye Horizontal Section Zonules Crystalline Lens Vitreous Sclera Retina Macula And Fovea Optic Nerve

More information

Aberrations and Visual Performance: Part I: How aberrations affect vision

Aberrations and Visual Performance: Part I: How aberrations affect vision Aberrations and Visual Performance: Part I: How aberrations affect vision Raymond A. Applegate, OD, Ph.D. Professor and Borish Chair of Optometry University of Houston Houston, TX, USA Aspects of this

More information

Siesta 100. Training + Certification Guide. Bringing eye care professionals the finest quality, custom GP lens designs.

Siesta 100. Training + Certification Guide. Bringing eye care professionals the finest quality, custom GP lens designs. o r t h o k er a t o l o g y Training + Certification Guide Bringing eye care professionals the finest quality, custom GP lens designs. 800-792-1095 tfoptics.com Training and Certification Corneal Shape

More information

Lecture 8. Lecture 8. r 1

Lecture 8. Lecture 8. r 1 Lecture 8 Achromat Design Design starts with desired Next choose your glass materials, i.e. Find P D P D, then get f D P D K K Choose radii (still some freedom left in choice of radii for minimization

More information

Review of Basic Principles in Optics, Wavefront and Wavefront Error

Review of Basic Principles in Optics, Wavefront and Wavefront Error Review of Basic Principles in Optics, Wavefront and Wavefront Error Austin Roorda, Ph.D. University of California, Berkeley Google my name to find copies of these slides for free use and distribution Geometrical

More information

Section 22. The Eye The Eye. Ciliary Muscle. Sclera. Zonules. Macula And Fovea. Iris. Retina. Pupil. Optical Axis.

Section 22. The Eye The Eye. Ciliary Muscle. Sclera. Zonules. Macula And Fovea. Iris. Retina. Pupil. Optical Axis. Section 22 The Eye 22-1 The Eye Optical Axis Visual Axis Pupil Iris Cornea Right Eye Horizontal Section Ciliary Muscle Zonules Crystalline Lens Vitreous Sclera Retina Macula And Fovea Optic Nerve 22-2

More information

Auto Ref/ Keratometer / Auto Refractometer ARK-1 / AR-1

Auto Ref/ Keratometer / Auto Refractometer ARK-1 / AR-1 Auto Ref/ Keratometer / Auto Refractometer ARK-1 / AR-1 The Superior Auto and Auto What is the superior auto ref / The ARK-1 / AR-1 series speak for themselves, and auto refractometer generating greater

More information

Quality Testing of Intraocular Lenses. OptiSpheric IOL Family and WaveMaster IOL 2

Quality Testing of Intraocular Lenses. OptiSpheric IOL Family and WaveMaster IOL 2 Quality Testing of Intraocular Lenses OptiSpheric IOL Family and WaveMaster IOL 2 LEADING TO THE FUTURE OF OPTICS Optical systems have changed the world. And they will continue to do so. TRIOPTICS is significantly

More information

AUTO REF / KERATOMETER ARK-560A / 530A / 510A

AUTO REF / KERATOMETER ARK-560A / 530A / 510A AUTO REF / KERATOMETER ARK-560A / 530A / 510A Auto Ref/Keratometer ARK-560A / 530A / 510A Excellent Measurement Accuracy Highly Accurate Refractometer The combination of new measuring principle - Pupil

More information

ROTATIONAL STABILITY MAKES THE DIFFERENCE

ROTATIONAL STABILITY MAKES THE DIFFERENCE The Bi-Flex platform the proven platform of Excellence 01 Proven Stability less than 02 Optimal biomaterials 2 degrees long term rotation 03 Posterior Toric Lens surface with marks indicating the flat

More information

Quality Testing of Intraocular Lenses. OptiSpheric IOL Family and WaveMaster IOL 2

Quality Testing of Intraocular Lenses. OptiSpheric IOL Family and WaveMaster IOL 2 Quality Testing of Intraocular Lenses OptiSpheric IOL Family and WaveMaster IOL 2 LEADING TO THE FUTURE OF OPTICS Optical systems have changed the world. And they will continue to do so. TRIOPTICS is significantly

More information

Roadmap to presbyopic success

Roadmap to presbyopic success Roadmap to presbyopic success Miltos O Balidis MD, PhD, FEBOphth, ICOphth Early experience with Presbyopic correction 2003 Binocular Distance-Corrected Intermediate and Near Vision Binocular Distance-Corrected

More information

G.P. MULTIFOCAL LENSES: A FITTING WORKSHOP

G.P. MULTIFOCAL LENSES: A FITTING WORKSHOP G.P. MULTIFOCAL LENSES: A FITTING WORKSHOP Susan J. Gromacki, OD, MS, FAAO, FSLS Daniel G. Fuller, OD, FAAO, FSLS Cornea, Contact Lenses and Refractive Technologies Section The American Academy of Optometry

More information

Fabrication of 6.5 m f/1.25 Mirrors for the MMT and Magellan Telescopes

Fabrication of 6.5 m f/1.25 Mirrors for the MMT and Magellan Telescopes Fabrication of 6.5 m f/1.25 Mirrors for the MMT and Magellan Telescopes H. M. Martin, R. G. Allen, J. H. Burge, L. R. Dettmann, D. A. Ketelsen, W. C. Kittrell, S. M. Miller and S. C. West Steward Observatory,

More information