Unique Aberration-Free IOL: A Vision that Patients
|
|
- Theodore Chase
- 5 years ago
- Views:
Transcription
1 Unique Aberration-Free IOL: A Vision that Patients Can Appreciate
2 An Aspheric Optic for Improved Quality of Vision n Traditional spherical IOLs create Bilateral implantation study spherical aberration and reduce contrast sensitivity High Order Aberrations at months: 6mm pupil n With, unique aspheric 2. anterior and posterior surfaces are aberration neutral n The result? Clinical outcomes.86 Total HOA 1.4 demonstrate a reduction in overall higher order aberrations 1 coma SA 1. n Contrast sensitivity under photopic.6.8 or mesopic lighting conditions is similar to silicone aspheric aberrated IOL Akreos Adapt (n=2) Akreos Adapt AO (n=2) G. Lofoco. Influence of Aspheric and Spherical IOLs on Higher-Order Aberrations and Functional Vision: Results of a Comparative Multi-center Study. ASCRS Bilateral implantation study Mesopic Contrast Sensitivity: cd/m Contrast Sensitivity Contrast Sensitivity Photopic Contrast Sensitivity: 85 cd/m , ,5 Spatial Frequency (CPD) (n=8) Spatial Frequency (CPD) Silicone Aspheric Aberrated IOL (n=8) B. Johansson et al. Swedish multi-center study to compare the optical performance of the Akreos Adapt Advanced Optic (AO) IOL and the Tecnis Z9. ASCRS 26. 2
3 Uniform Power Designed to Work in Every Eye n No eye is optically perfect The Natural Phakic Eye n Constant power from centre to edge helps to improve vision by providing consistent power across the entire optic surface Iris n is designed to provide OPTICAL AXIS (Cornea to Lens) predictable, repeatable refractive outcomes for all cataract patients, regardless of corneal shape, pupil size, as well as pupil or capsular bag centration VISUAL AXIS (Object to Fovea) Fovea Lens n Clinical results show excellent high Retina and low contrast BCVA comparable to a middle-age phakic eye All axes in the eye are not perfectly aligned and no two eyes are the same shape so you need IOLs that work with imperfect conditions. BCVA compared to phakic eyes. 2/4..2 2/ /25.1 2/4 patients (mean age: 7-year-old) patients (mean age: 7-year-old) 2/2 2/ IogMar IogMar 6 months 2/2 Normal phakic population (mean age: 4-year-old) 6 months 1 year -.1 2/ /2 Normal phakic population (mean age: 4-year-old) 2/ High Contrast (n=5) 1 year Low Contrast (n=5) V. Pfeifer. Clinical evaluation of a new aspheric IOL: the Akreos Adapt Advanced Optics (AO). Data from a pilot study at six months follow up. ASCRS 26.
4 Aberration-Free Design Helps to Enhance Depth of Field n The phakic eye has some natural level of positive spherical aberration n Positive spherical aberration helps the phakic eye achieve better depth of field n maintains the natural, positive spherical aberrations compared to aspheric, aberrated IOLs 2 (top figure) n With its aberration-free design, helps to significantly improve depth of field in comparison to an aspheric aberrated IOL2 (bottom figure) Natural Functionality Bilateral implantation study Spherical Aberrations Depth of focus in intermediate vision 1 Silicone Aspheric Aberrated IOL,8 RMS,6,4,2 -.2 Z4 4mm Z4 4,5mm Corneal Peripheral rays Mean Depth of Field4 p=, Corneal Medium rays Number of patients Z4 5mm Silicone Aspheric Aberrated IOL.85 Dpt.71 Dpt Corneal Central rays In intermediate vision more distant objects are seen through central corneal rays whereas closer objects are seen through peripheral corneal rays Johansson et al. Swedish multi-centre study to compare the optical performance of B the Akreos Adapt Advanced Optic (AO) IOL and the Tecnis Z9. ASCRS 26. Measured with the Strehl ratio as described by S. Marcos et al. Implantation of Spherical and Aspheric IOLs. Journal of Refractive Surgery. May June 25; 21:1 1. 4
5 A Visual Difference Patients Appreciate n A masked, subjective patient n Patients had no way of knowing assessment following cataract surgery showed that twice as many patients prefer the vision in their eye2 (left figure) which lens was implanted in their eyes n Patients also reported fewer visual disturbances in their eye compared to the silicone aspheric aberrated IOL eye2 (right figure) Bilateral implantation study: double-masked questionnaire Any preference for one eye Less dysphotopsia in one eye % 1 Silicone Aspheric Aberrated IOL 14% 1 No difference 58% (n=8) 2 % Silicone Aspheric Aberrated IOL 11% No difference 56% (n=55) B. Johansson et al. Swedish multi-centre study to compare the optical performance of the Akreos Adapt Advanced Optic (AO) IOL and the Tecnis Z9. ASCRS 26. 5
6 For Optimised Effectiveness against PCO n The unique Square-Edge Technology and a 6 posterior barrier reduce cell migration following implantation n EPCO analysis shows just how effective the design is in blocking cell growth n Results are comparable to the best performing acrylic IOLs5 Akreos Advanced Optics EPCO months 6mm optic area mm central area (n=42) (n=48) (n=41) EPCO 12 months Limit at which PCO does not require Nd:Yag capsulotomy* One-Piece Hydrophobic Acrylic Lens mm optic area (n=41) mm central area (n=41) 6mm optic area (n=12) mm central area (n=12) * Nd:Yag capsulotomy usually performed beyond.5 to 1., depending on PCO location and patient s complaint. 5 V. Pfeifer. Clinical evaluation of a new aspheric IOL: the Akreos Adapt Advanced Optics (AO). Data from a pilot study at six months follow up. ASCRS 26. Data on file. 6
7 Efficient Implantation through an Unenlarged Phaco Incision n The Akreos Single-Use Insertion Device enables implantation of the through a 2.8mm phaco incision n Improved plunger design provides symmetrical unfolding and easier placement of the lead haptics into the capsular bag n The flat loading, single-hand injection makes quick work of lens implantation Single-Use Lens Delivery System Akreos Single-Use Insertion Device AI-28B 1. Place the lens flat in to the loading deck 2. Close the injector and fit the tip 7. Advance the plunger and deliver the lens
8 Akreos Advanced Optics System Model: Adapt AO DIOPTER RANGE:. through 9. in 1. Dpt MATERIAL: 26% acrylic material, 1. through. in.5 Dpt UV absorber, Refractive index: (hydrated) LENS CONSTANTS: OPTIC: A-Constant* (SRK/T) Biconvex aspheric anterior and posterior, Optic body: 6mm ACD* Surgeon Factor* HAPTICS: ORDER CODES: One-piece, º angulation Lens in plastic vial: ADAPTAOP or ADAPTAOTP OVERALL DIAMETER: 11.mm from. to 15. Dpt 1.7mm from 15.5 to 22. Dpt Applanation Immersion A-scan A-scan or IOL Master* Injector: AI-28B 1.5mm from 22.5 to. Dpt Belgium/Luxembourg Tel: Fax: Germany/ Switzerland/Austria Tel: Fax: Portugal Tel: Fax: Emerging Markets Tel: Fax: Italy Tel: Spain Netherlands France Tel: Fax: Tel: Fax: Tel: Fax: South Africa Tel: Fax: Tel: Fax: United Kingdom Tel: Fax: Nordic Countries For information or Customer Service please contact your local representative or distributor. Bausch & Lomb European Office, Bausch + Lomb House, London Road, Kingston-upon-Thames, Surrey KT2 6TN, UK. Tel: Fax: Bausch & Lomb Incorporated / March211 / version 2 / / denote trademarks of Bausch & Lomb Incorporated * A-Constant, ACD and Surgeon Factor are estimates only. Latest update March 211. It is recommended that each surgeon develop his or her own values.
Not everyone can do this. Introducing RayOne with patented Lock & Roll TM technology for the smallest fully preloaded IOL incision
Not everyone can do this Introducing RayOne with patented Lock & Roll TM technology for the smallest fully preloaded IOL incision RayOne fully preloaded IOL injection system, designed to deliver without
More informationSEE BEYOND WITH FULLRANGE OPTICS. Developed by Hanita Lenses
SEE BEYOND WITH FULLRANGE OPTICS Developed by Hanita Lenses SEE beyond with FullRange optics FullRange optic lenses are proven, highlyreliable and safe intraocular lenses designed to provide a solution
More informationIOL Types. Hazem Elbedewy. M.D., FRCS (Glasg.) Lecturer of Ophthalmology Tanta university
IOL Types Hazem Elbedewy M.D., FRCS (Glasg.) Lecturer of Ophthalmology Tanta university Artificial intraocular lenses are used to replace the eye natural lens when it has been removed during cataract surgery.
More informationThe design is distinctive. The outcomes are clear. Defocus tolerance 1 Glistening-free performance 1,2 Predictable outcomes 1
The design is distinctive. The outcomes are clear. Defocus tolerance 1 Glistening-free performance 1,2 Predictable outcomes 1 The clear choice for consistent visual excellence. For over 165 years Bausch
More informationLong-term quality of vision is what every patient expects
Long-term quality of vision is what every patient expects Innovative combination of HOYA technologies provides: 1-piece aspheric lens with Vivinex hydrophobic acrylic material Unique surface treatment
More informationCrystalens AO: Accommodating, Aberration-Free, Aspheric Y. Ralph Chu, MD Chu Vision Institute Bloomington, MN
Crystalens AO: Accommodating, Aberration-Free, Aspheric Y. Ralph Chu, MD Chu Vision Institute Bloomington, MN Financial Disclosure Advanced Medical Optics Allergan Bausch & Lomb PowerVision Revision Optics
More informationNOW. Approved for NTIOL classification from CMS Available in Quar ter Diopter Powers. Accommodating. Aberration Free. Aspheric.
NOW Approved for NTIOL classification from CMS Available in Quar ter Diopter Powers Accommodating. Aberration Free. Aspheric. Accommodation Meets Asphericity in AO Merging Innovation & Proven Design The
More informationClinical Evaluation 3-month Follow-up Report
Clinical Evaluation 3-month Follow-up Report Of SeeLens HP Intraocular Lens 27 December 2010 version 1.1 1of 16 Table of Contents TABLE OF CONTENTS... 1 OBJECTIVES... 2 EFFICACY AND SAFETY ASSESSMENTS...
More informationTHE ASPHERIC PRELOADED INJECTION
New from STAAR for Safe and Easy Implantation THE ASPHERIC PRELOADED INJECTION S Y S T E M PRELOADED INJECTION SYSTEM FOR SIMPLE AND EASY IOL DELIVERY SAFE The KS3-Ai features an aspheric IOL preloaded
More informationAT LISA tri 839MP and AT LISA tri toric 939MP from ZEISS The innovative trifocal IOL concept providing True Living Vision to more patients
Premium Trifocal MICS OVDs IOLs AT LISA tri 839MP and AT LISA tri toric 939MP from ZEISS The innovative trifocal IOL concept providing True Living Vision to more patients The moment you help your patients
More informationNEW. AT LISA tri 839MP and AT LISA tri toric 939MP from ZEISS The innovative trifocal IOL concept providing True Living Vision to more patients
Premium Trifocal MICS OVDs IOLs NEW AT LISA tri 839MP and AT LISA tri toric 939MP from ZEISS The innovative trifocal IOL concept providing True Living Vision to more patients Trifocal toric IOL The moment
More informationROTATIONAL STABILITY MAKES THE DIFFERENCE
The Bi-Flex platform the proven platform of Excellence 01 Proven Stability less than 02 Optimal biomaterials 2 degrees long term rotation 03 Posterior Toric Lens surface with marks indicating the flat
More informationRayOne Hydrophobic IOL. New design. New standard MADE IN UK
RayOne Hydrophobic IOL New design. New standard MADE IN UK Setting new standards since 1949 About Rayner When Sir Harold Ridley designed the world s first IOL in 1949, he chose Rayner to manufacture this
More informationday night convinced supreme contrast sensitivity THE IOL FOR DAY & NIGHT
day supreme contrast sensitivity night convinced THE IOL FOR DAY & NIGHT The IOL for DAY & NIGhT UnIQUE form and features Innovative blue light filtering Excellent quality of vision Maximum depth of focus
More information*Simulated vision. **Individual results may vary and are not guaranteed. Visual Performance When It s Needed Most
Simulated vision. Individual results may vary and are not guaranteed. Visual Performance When It s Needed Most The aspheric design of the AcrySof IQ IOL results in improved clarity and image quality. The
More informationProduct Portfolio. Sulcoflex Pseudophakic Supplementary IOLs
Product Portfolio Sulcoflex Pseudophakic Supplementary IOLs Sulcoflex Pseudophakic Supplementary IOLs For when compromise is not an option As a cataract and refractive surgeon, achieving the best possible
More informationMaximum Light Transmission. Pupil-independent Light Distribution. 3.75D Near Addition Improved Intermediate Vision
Multifocal Maximum Light Transmission Pupil-independent Light Distribution Better Visual Quality Increased Contrast Sensitivity 3.75D Near Addition Improved Intermediate Vision Visual Performance After
More informationImproving Lifestyle Vision. with Small Aperture Optics
Improving Lifestyle Vision with Small Aperture Optics The Small Aperture Premium Lens Solution The IC-8 small aperture intraocular lens (IOL) is a revolutionary lens that extends depth of focus by combining
More informationCauses of refractive error post premium IOL s 3/17/2015. Instruction course: Refining the Refractive Error After Premium IOL s.
Instruction course: Refining the Refractive Error After Premium IOL s. Senior Instructor: Mounir Khalifa, MD Instructors: David Hardten,MD Scott MacRea,MD Matteo Piovella,MD Dr. Khalifa: Causes of refractive
More informationDr. Magda Rau Eye Clinic Cham, Germany
3 and 6 Months clinical Results after Implantation of OptiVis Diffractive-refractive Multifocal IOL Dr. Magda Rau Eye Clinic Cham, Germany Refractive zone of Progressive power for Far to Intermediate
More informationGlistening-Free Hydrophobic Acrylic IOL. Glistening-Free Hydrophobic Acrylic IOL
Glistening-Free Hydrophobic Acrylic IOL Proprietary Polymer Composition Packaged Dry UD Aspheric Optic Optimized Refractive Index All SquareTM Enhanced Edge Largest Diopter Range -05.00D to 42.00D Modified
More informationVisual Outcomes of Two Aspheric PCIOLs: Tecnis Z9000 versus Akreos AO
Visual Outcomes of Two Aspheric PCIOLs: Tecnis Z9000 versus Akreos AO Ahmad-Reza Baghi, MD; Mohammad-Reza Jafarinasab, MD; Hossein Ziaei, MD; Zahra Rahmani, MD Shaheed Beheshti Medical University, Tehran,
More informationClinical Update for Presbyopic Lens Options
Clinical Update for Presbyopic Lens Options Gregory D. Searcy, M.D. Erdey Searcy Eye Group Columbus, Ohio The Problem = Spherical Optics Marginal Rays Spherical IOL Light Rays Paraxial Rays Spherical Aberration
More informationSulcoflex. For when perfection is the only option! Pseudophakic Sulcus Fixated Secondary IOLs. Sulcoflex Aspheric. Sulcoflex Toric
Sulcoflex Pseudophakic Sulcus Fixated Secondary IOLs Sulcoflex Aspheric Sulcoflex Toric Sulcoflex Multifocal For when perfection is the only option! Sulcoflex Pseudophakic Sulcus Fixated Secondary IOLs
More informationAberrations Before and After Implantation of an Aspheric IOL
Ocular High Order Aberrations Before and After Implantation of an Aspheric IOL Fabrizio I. Camesasca, MD Massimo Vitali, Orthoptist Milan, Italy I have no financial interest to disclose Wavefront Measurement
More informationProduct Portfolio. Sulcoflex Pseudophakic Supplementary IOLs. Your skill. Our vision.
Product Portfolio Sulcoflex Pseudophakic Supplementary IOLs Your skill. Our vision. Sulcoflex Pseudophakic Supplementary IOLs For when compromise is not an option As a cataract and refractive surgeon,
More informationPROGRESSIVE VISION WITHIN FULL ACCOMMODATIVE RANGE
PROGRESSIVE VISION WITHIN FULL ACCOMMODATIVE RANGE PROGRESSIVE VISION Progressive vision within full accomodative range 03 Suitable for sub 2 mm MICS 01 PAD Progressive- Apodized-Diffractive 02 Aspheric
More informationComparative Study Between the High Order Aberrations Before and After Cataract Surgery Using Two Different Types of IOLS
Cronicon OPEN ACCESS EC OPHTHALMOLOGY Research Article Comparative Study Between the High Order Aberrations Before and After Cataract Surgery Using Two Different Types of IOLS Ahmed Abdelkareem Elmassry*,
More informationClinical Evaluation 3-month Follow-up Report
Clinical Evaluation 3-month Follow-up Report Of SeeLens AF Intraocular Lens 30 June 2010 version 1.1 1 of 21 Table of Contents: Objectives 2 Medical device specification and administration 4 Methods 9
More informationHYDROPHILIC ACRYLIC ADVANCED POLYMER
PRODUCT CATALOGUE i-medical GmbH founded in Heidelberg Germany brings quality products to the world of ophthalmic surgery. With many years experience in this medical speciality, we at i-medical are well
More informationChoosing the Proper Power for the IOL. Brannon Aden, MD Miles H. Friedlander, MD, FACS
Choosing the Proper Power for the IOL Brannon Aden, MD Miles H. Friedlander, MD, FACS Goal s of Surgery Have Changed. In past the goal was good visual outcome Now an equal goal is a good refractive outcome
More informationQuality of Vision With Multifocal Progressive Diffractive Lens: Two-Year Follow-up
Quality of Vision With Multifocal Progressive Diffractive Lens: Two-Year Follow-up Antonio Mocellin, MD & Matteo Piovella, MD CMA, Centro di Microchirurgia Ambulatoriale Monza (Milan) Italy Dr Piovella
More informationTechnicians & Nurses Program
ASCRS ASOA Symposium & Congress Technicians & Nurses Program May 6-10, 2016 New Orleans ADVANCED BIOMETRY AND IOL CALCULATIONS Financial Disclosures No relevant disclosures Karen Bachman, COMT, ROUB The
More information7 DO IT. A SAFER WAY TO TRIFOCALITY * : ELEVATED PHASE SHIFT (EPS) ** 7 DIFFRACTIVE RINGS FOR OPTIMAL LIGHT DISTRIBUTION AND LESS DISTURBANCE
A SAFER WAY TO TRIFOCALITY * : ELEVATED PHASE SHIFT (EPS) ** 7 DIFFRACTIVE RINGS FOR OPTIMAL LIGHT DISTRIBUTION AND LESS DISTURBANCE 7 DO IT. TRIFOCAL PERFORMANCE & GLASS INDEPENDENCY UNCOMPROMISED CONTRAST
More informationEvolution of Diffractive Multifocal Intraocular Lenses
Evolution of Diffractive Multifocal Intraocular Lenses Wavefront Congress February 24, 2007 Michael J. Simpson, Ph.D. Alcon Research, Ltd., Fort Worth, Texas Presentation Overview Multifocal IOLs two lens
More informationCONTENTS. HYDROPHILIC IOLs. Bi-Flex PIL-MA hydrophilic preloaded P / PY 677PT / PTY 677PMY 677PMTY. Bi-Flex HL...
Bi-Flex IOL RANGE CONTENTS HYDROPHILIC IOLs Bi-Flex PIL-MA hydrophilic preloaded... 1 677P / PY 677PT / PTY 677PMY 677PMTY Bi-Flex HL... 2 677AB / ABY Bi-Flex T... 3 677TA / TB 677TAY / TBY Bi-Flex M...
More informationNEW THE WORLD S FIRST AND ONLY SINUSOIDAL TRIFOCAL IOL
NEW THE WORLD S FIRST AND ONLY SINUSOIDAL TRIFOCAL IOL ALL TRIFOCAL IOLS ARE NOT THE SAME! Seamless Vision Near Intermediate Far Light Figure 1: Comparison of MTF Values 1,2 THE WORLD S FIRST AND ONLY
More informationAccommodating IOL s History and Clinical Management
Accommodating IOL s History and Clinical Management Bausch & Lomb Surgical Aliso Viejo, CA Genesis of an Accommodating IOL 1 Observations with Plate IOLs Stuart Cumming 1989 Some plate haptic IOL patients
More informationTHE XTRAFOCUS IS AN ELEGANT SOLUTION TO COMPLEX CASES.
XtraFocus THE XTRAFOCUS IS AN ELEGANT SOLUTION TO COMPLEX CASES. CONTENT Based on the well-established principle of pinhole optics, this intraocular implant represents an innovative alternative for the
More informationFEA of Prosthetic Lens Insertion During Cataract Surgery
Visit the SIMULIA Resource Center for more customer examples. FEA of Prosthetic Lens Insertion During Cataract Surgery R. Stupplebeen, C. Liu, X. Qin Bausch + Lomb, SIMULIA, SIMULIA Abstract: Cataract
More informationHOYA aspherical IOL with ABC (Aspheric Balanced Curve) Design
HOYA aspherical IOL with ABC (Aspheric Balanced Curve) Design Contents Basics of asphericity Visual quality and aspheric IOL Features of HOYA ABC Design 2 What is asphericity? Deviating from the spherical
More informationThe complete choice in refractive lens solutions
The complete choice in refractive lens solutions The VeriFlex phakic IOL is part of Advanced Medical Optics range of high-contrast, high-quality refractive lens solutions. In addition to excellent training
More informationCentre Hospitalier Universitaire et Psychiatrique de Mons-Borinage. B-Flex Multifocal. Dr Emmanuel Van Acker Belgium
Centre Hospitalier Universitaire et Psychiatrique de Mons-Borinage B-Flex Multifocal Dr Emmanuel Van Acker Belgium Comparison of clinical outcomes and patient satisfaction after implantation of two different
More informationRaise your expectations. Deliver theirs.
66 EXTENDED RANGE OF VISION MONOFOCAL-LIKE DISTANCE Raise your expectations. Deliver theirs. Now you can give your patients the best of both worlds with the first and only hybrid designed monofocal-multifocal
More informationMultifocal Progressive Diffractive Lens to Improve Light Distribuition and Avoid Light Loss: Two Years Clinical Results
Multifocal Progressive Diffractive Lens to Improve Light Distribuition and Avoid Light Loss: Two Years Clinical Results Matteo Piovella MD & Barbara Kusa MD CMA, Centro di Microchirurgia Ambulatoriale
More informationPreloaded. PreciSAL. EZ Toric
Preloaded PreciSAL EZ Toric Experience the beauty with new vision Make a difference every time 1 Why you should choose MBI 3 Our vision is clear 4 PreciSAL quality 5 MTF of PreciSAL 7 Optical precision
More informationMultifocal and Accommodative
What is an IOL? An intraocular lens (or IOL) is a tiny, artificial lens for the eye. It replaces the eye's natural lens. Retina Cornea Lens Macula The eye's normally clear lens bends (refracts) light rays
More informationOCULUS Pentacam AXL Always an Axial Length Ahead
OCULUS Pentacam AXL Always an Axial Length Ahead EFFICIENCY AND BETTER WORKFLOW Your Cataract Workstation! The new Pentacam AXL is an alliance of the time-tested Pentacam technology with high-precision
More informationPrinciples and clinical applications of ray-tracing aberrometry (Part II)
UPDATE/REVIEW Principles and clinical applications of ray-tracing aberrometry (Part II) Alfredo Castillo Gómez, MD, PhD 1 ; Antonio Verdejo del Rey, OD 2 ; Carlos Palomino Bautista, MD 3 ; Ana Escalada
More informationEXCHANGE. Financial Disclosure. Clinical pearls In advanced anterior segment surgery being able to do a IOL exchange is a must. Why Do an Exchange
Financial Disclosure D. Ayres, MD Cornea Service IOLBrandon Wills Eye Hospital EXCHANGE Alcon Allergan AMO Bausch and Lomb TearScience BioTissue Why Do an Exchange Refractive surprise after cataract surgery
More informationTheoretical Considerations
Bedeutung der Linsenposition für die optische Abbildugsqualität- Ein neues Messverfahren mittels Purkinje Reflexbildern SA(-) Acri.Tec 35A Hoya FY60AD Tecnis ZCB00 AcrySof IQ U. Mester, T. Sauer, H.Kaymak
More informationDiffractive Optics. Multifocal Lenses. Correction of Pseudophakic Presbyopia with Multifocal IOLs. Basic Designs
Correction of Pseudophakic Presbyopia with Multifocal IOLs GEORGE H.H. BEIKO, B.M.,B.Ch.,FRCSC ST. CATHARINES, CANADA ASSIST PROF, MCMASTER UNIV george.beiko@sympatico.ca AMO Tecnis MFIOL Alcon ReSTOR
More informationRefractive Power / Corneal Analyzer. OPD-Scan III
Refractive Power / Corneal Analyzer OPD-Scan III Comprehensive Vision Analysis and NIDEK, a global leader in ophthalmic and optometric equipment, has created the OPD-Scan III, the third generation aberrometer
More informationCorneal Asphericity and Retinal Image Quality: A Case Study and Simulations
Corneal Asphericity and Retinal Image Quality: A Case Study and Simulations Seema Somani PhD, Ashley Tuan OD, PhD, and Dimitri Chernyak PhD VISX Incorporated, 3400 Central Express Way, Santa Clara, CA
More informationIntraocular lens Difficulties
Intraocular lens Difficulties Sameh Fouda MD, FRCS Assistant Professor Of Ophthalmology Faculty Of Medicine, Zagazig University IOL in history Sir Harold Ridley, in the 1940s,discovered that shards of
More informationPATIENT SELECTION THE RIGHT PATIENT UNDERPROMISE AND OVERDELIVER THE PERFECT SPECTACLE FREE TREATMENT. Desires Less Dependence on glasses
Bilateral TECNIS MF versus Customized TECNIS MF - REZOOM Achieving Spectacle Independence THE PERFECT SPECTACLE FREE TREATMENT PATIENT SELECTION 1.ARE THEY INTERESTED IN BECOMING SPECTACLE FREE? 2.ARE
More informationTreatment of Presbyopia during Crystalline Lens Surgery A Review
Treatment of Presbyopia during Crystalline Lens Surgery A Review Pierre Bouchut Bordeaux Ophthalmic surgeons should treat presbyopia during crystalline lens surgery. Thanks to the quality and advancements
More informationSpecial Publication: Ophthalmochirurgie Supplement 2/2009 (Original printed issue available in the German language)
Special Publication: Ophthalmochirurgie Supplement 2/2009 (Original printed issue available in the German language) LENTIS Mplus - The one -and and-only Non--rotationally Symmetric Multifocal Lens Multi-center
More informationThe Miracle of Pi in Eye. Rajesh Khanna, MD
The Miracle of Pi in Eye Rajesh Khanna, MD Copyright 2013 Rajesh Khanna, MD All rights reserved. Pi in eye DEDICATION This book is dedicated to all my patients who placed their faith in me and trusted
More informationOcular Scatter. Rayleigh Scattering
Ocular Scatter The are several sources of stray light in the eye including the cornea, transmission through the iris and the crystalline lens. Cornea tends to have Rayleigh Scatter Lens follows inverse
More informationI N M A D E F R A N C E. Hydrophobic monofocal NEW QUALITY SAFETY STABILITY TECHNICAL BROCHURE
ENGINEERED AND M A D E I N F R A N C E Hydrophobic monofocal NEW QUALITY SAFETY STABILITY TECHNICAL BROCHURE Genesis, is a new hydrophobic intraocular lens developed and manufactured by CUTTING EDGE to
More informationWave Front Topography. ReSeeVit Evolution Topography Module for Modi Topographer
Wave Front Topography ReSeeVit Evolution Topography Module for Modi Topographer Introduction The aberrations in the central optical zone have a greater effect than those closer to the edge. From an optical
More informationThe Impact of New Generation Aspherical Soft Contact Lenses on Quality of Vision: A Comparison with Spherical Contact Lenses and Spectacle Correction
Deniz Oral, Maryo C. Kohen, Melda Yenerel, Ebru Gorgun, Sule Ziylan, Ferda Ciftci Yeditepe University Faculty of Medicine, Department of Ophthalmology, Istanbul Introduction The correction of higher order
More informationThe Aberration-Free IOL:
The Aberration-Free IOL: Advanced Optical Performance Independent of Patient Profile Griffith E. Altmann, M.S., M.B.A.; Keith H. Edwards, BSc FCOptom Dip CLP FAAO, Bausch & Lomb Some of these results were
More informationCustomized intraocular lenses
Customized intraocular lenses Challenges and limitations Achim Langenbucher, Simon Schröder & Timo Eppig Customized IOL what does this mean? Aspherical IOL Diffractive multifocal IOL Spherical IOL Customized
More informationForget Most Everything! The Surgical Management of Presbyopia 2/23/2016. Refraction vs. Diffraction. Presbyopic IOL s Patient Expectations
The Surgical Management of Presbyopia Presbyopic IOL s 2011 B I L L T U L L O, O D Patient Expectations What they say is I want to be able to read The Center of a Presbyope s World What they want is Accommodation
More informationRetinal stray light originating from intraocular lenses and its effect on visual performance van der Mooren, Marie Huibert
University of Groningen Retinal stray light originating from intraocular lenses and its effect on visual performance van der Mooren, Marie Huibert IMPORTANT NOTE: You are advised to consult the publisher's
More informationCOMPARISON OF THE MEDICONTUR 860FAB
COMPARISON OF THE MEDICONTUR 860FAB HYDROPHOBIC IOL AND THE ACRYSOF IQ LONG TERM FOLLOW UP Péter Vámosi MD, Amanda Argay MD, Zsófia Rupnik MD, János Fekete Péterfy Sándor Hospital Budapest, Hungary PREFERENCE
More informationJózsef Győry. Veszprem, Hungary
Long term functional and morphological outcomes and patient satisfaction after cataract surgery with BiFlex M implantation with / without posterior central circular capsulorhexis (PCCC) József Győry Veszprem,
More information4/2/2015. Bonnie An Henderson MD Clinical Professor of Ophthalmology Tufts University School of Medicine Ophthalmic Consultants of Boston
Imaging Modalities That Help Maximize Uncorrected Visual Outcomes After Cataract Surgery Dr.BonnieAn Henderson, MD Dr. Kalpana Narendran, DNB Dr.Prabhu vijayaraghavan, M.S, FICO Dr. Sandra Chandramouli,DNB
More informationChoices and Vision. Jeffrey Koziol M.D. Thursday, December 6, 12
Choices and Vision Jeffrey Koziol M.D. How does the eye work? What is myopia? What is hyperopia? What is astigmatism? What is presbyopia? How the eye works How the Eye Works 3 How the eye works Light rays
More informationComparison of higher order aberrations with spherical and aspheric IOLs compared to normal phakic eyes
European Journal of Ophthalmology / Vol. 18 no. 5, 2008 / pp. 728-732 Comparison of higher order aberrations with spherical and aspheric IOLs compared to normal phakic eyes M. RĘKAS, K. KRIX-JACHYM, B.
More informationUniversity of Groningen. Young eyes for elderly people van Gaalen, Kim
University of Groningen Young eyes for elderly people van Gaalen, Kim IMPORTANT NOTE: You are advised to consult the publisher's version (publisher's PDF) if you wish to cite from it. Please check the
More information10/25/2017. Financial Disclosures. Do your patients complain of? Are you frustrated by remake after remake? What is wavefront error (WFE)?
Wavefront-Guided Optics in Clinic: Financial Disclosures The New Frontier November 4, 2017 Matthew J. Kauffman, OD, FAAO, FSLS STAPLE Program Soft Toric and Presbyopic Lens Education Gas Permeable Lens
More informationChoices and Vision. Jeffrey Koziol M.D. Friday, December 7, 12
Choices and Vision Jeffrey Koziol M.D. How does the eye work? What is myopia? What is hyperopia? What is astigmatism? What is presbyopia? How the eye works Light rays enter the eye through the clear cornea,
More informationWhat is Wavefront Aberration? Custom Contact Lenses For Vision Improvement Are They Feasible In A Disposable World?
Custom Contact Lenses For Vision Improvement Are They Feasible In A Disposable World? Ian Cox, BOptom, PhD, FAAO Distinguished Research Fellow Bausch & Lomb, Rochester, NY Acknowledgements Center for Visual
More informationCorporate Perspective Alcon Unanswered Technical Challenges that Still Need to be Overcome
Corporate Perspective Alcon Unanswered Technical Challenges that Still Need to be Overcome Ronald Krueger, MD Refractive Industry Challenges Diagnostic Improvement Optimal Laser Performance Corneal Factors
More informationEP A1 (19) (11) EP A1 (12) EUROPEAN PATENT APPLICATION. (43) Date of publication: Bulletin 2010/16
(19) (12) EUROPEAN PATENT APPLICATION (11) EP 2 177 179 A1 (43) Date of publication: 21.04. Bulletin /16 (1) Int Cl.: A61F 2/16 (06.01) (21) Application number: 08166689.3 (22) Date of filing: 1..08 (84)
More informationASPIRA PUBLICATION LIST
ASPIRA PUBLICATION LIST ASPIRA-aA / MC 6125 AS PR2 PR3 Eppig T, Scholz K, Löffler A, et al. Effect of decentration and tilt on the image quality of aspheric intraocular lens designs in a model eye J Cataract
More informationUpdate on Aspheric IOL Technology
Peer-Reviewed Literature: Update on Aspheric IOL Technology Editor: Ming Wang, MD, PhD, Clinical Associate Professor of Ophthalmology at the University of Tennessee and Director of the Wang Vision Institute
More informationSulcoflex Pseudophakic Supplementary IOLs
Supplement to November/December 2009 Sulcoflex Pseudophakic Supplementary IOLs Roundtable discussion featuring comments from Charles Claoué, MA, MD, DO, FRCS, FRCOphth, FEBO, MAE; Michael Amon, MD; Robert
More informationAHEAD Superior technology, thoughtfully designed with you in mind for an intelligent approach to cataract surgery.
ALWAYS THINKING AHEAD Superior technology, thoughtfully designed with you in mind for an intelligent approach to cataract surgery. The LENSAR Laser System was designed with your efficiency in mind, so
More informationObjective and subjective outcomes in comparing three different aspheric intraocular lens implants with their spherical counterparts
(2009) 23, 877 883 & 2009 Macmillan Publishers Limited All rights reserved 0950-222X/09 $32.00 www.nature.com/eye Objective and subjective outcomes in comparing three different aspheric intraocular lens
More informationOptical Path Difference Scanning System OPD-Scan II ARK-10000
Optical Path Difference Scanning System OPD-Scan II ARK-10000 Optical Path Difference Scanning System OPD-Scan II ARK-10000 Accurate and Reliable Data for Optic Diagnostics The OPD-Scan II provides information
More informationThe Dysphotopsia Mystery. John J. Bussa, M.D.
The Dysphotopsia Mystery John J. Bussa, M.D. Cataract Surgery Cataract Surgery Desirable Traits Foldable Lens Inert (non reactive) with a memory Thin folds tight and goes through a smaller incision
More informationThe Blueprint for Improved Image Quality
Insert to January 2009 The Blueprint for Improved Image Quality The function and design of the AcrySof IQ IOL. Supported by an educational grant from Alcon Laboratories, Inc. The Function and Design of
More informationCorneal Mapping over the Contact Lens. Challenge: Getting the Most out of Soft Contact Lens Multifocals
Contact Lens Management of the Challenging Patient Disclosures: Alcon Bausch + Lomb SpecialEyes Valley Contax Vistakon Contact Lens Challenges Matthew J. Lampa, OD, FAAO lampa@pacificu.edu Challenge: Getting
More informationAssessing Visual Quality With the Point Spread Function Using the NIDEK OPD-Scan II
Assessing Visual Quality With the Point Spread Function Using the NIDEK OPD-Scan II Edoardo A. Ligabue, MD; Cristina Giordano, OD ABSTRACT PURPOSE: To present the use of the point spread function (PSF)
More informationWide Diopter Range and Different Haptic Platforms
Monofocal Premium Material Innovative Optic Engineering Ultra Definition All Square 360 0 Enhanced Edge Wide Diopter Range and Different Haptic Platforms Best of Both Worlds Better Visual Quality Advanced
More informationUniversity of Groningen. Young eyes for elderly people van Gaalen, Kim
University of Groningen Young eyes for elderly people van Gaalen, Kim IMPORTANT NOTE: You are advised to consult the publisher's version (publisher's PDF) if you wish to cite from it. Please check the
More informationSoft CL Multifocals Design and Fitting. Soft Multifocal Lens Designs. Issues Surrounding Multifocals. Blur Interpretation. Simultaneous Vision Designs
Soft CL Multifocals Design and Fitting Mark Andre, FAAO Associate Professor of Optometry Pacific University Mark Andre, FAAO is affiliated with CooperVision, as a consultant. Issues Surrounding Multifocals
More informationSutureless, Glueless, Scleral Fixation of Single-Piece and Toric Intraocular Lens: A Novel Technique
Published online: July 21, 2015 1663 2699/15/0062 0239$39.50/0 This is an Open Access article licensed under the terms of the Creative Commons Attribution-NonCommercial 3.0 Unported license (CC BY-NC)
More informationIOL Review and FLACS Update
IOL Review and FLACS Update James Lee, M.D. Assistant Professor Texas Tech University Health Sciences Center Department of Ophthalmology & Visual Sciences Disclosures All material and information for this
More informationAdvanced Technology IOLs
Introduction Advanced Technology IOLs Stephen V. Scoper, MD Virginia Eye Consultants 2013 Cataract surgery has a refractive element Patient expectations are increased Close is no longer good enough The
More informationPágina 1 de 9 TopPage > Eye Care > Diagnostic > Wave-Front Analyzer KR-1W Wave-Front Analyzer KR-1W Perfection for Professionals : KR-1W Topcon, with its wealth of experience in designing and manufacturing
More informationOptical Characteristics of Next Generation Dual Optic IOL
Optical Characteristics of Next Generation Dual Optic IOL Scott Evans, MD Sanjeev Kasthurirangan, PhD Val Portney, PhD Financial Disclosures Scott Evans is an employee of Abbott Medical Optics Inc. Sanjeev
More informationSirius TOMOGRAPH AND CORNEAL TOPOGRAPHER
Sirius TOMOGRAPH AND CORNEAL TOPOGRAPHER EN Sirius TOMOGRAPH AND CORNEAL TOPOGRAPHER Combines placido disk topography with Sheimpflug tomography of the anterior segment. Sirius provides information on
More informationTHE BEST OF BOTH WORLDS Dual-Scheimpflug and Placido Reaching a new level in refractive screening
THE BEST OF BOTH WORLDS Dual-Scheimpflug and Placido Reaching a new level in refractive screening Clinical Applications Corneal Implant Planning The comes with a licensable corneal inlay software module
More informationComparison of Contrast Sensitivity, Higher- Order Aberrations and Subjective Visual Function after Different Aspheric Intraocular Lenses Implantation
Thai J Ophthalmol Vol. 25 No. 2 July-December 20 9 Original Article/π æπ åμâπ Comparison of Contrast Sensitivity, Higher- Order Aberrations and Subjective Visual Function after Different Aspheric Intraocular
More informationMultifocal Intraocular Lenses for the Treatment of Presbyopia: Benefits and Side-effects
Published on Points de Vue International Review of Ophthalmic Optics () Home > Multifocal Intraocular Lenses for the Treatment of Presbyopia: Benefits and Side-effects Multifocal Intraocular Lenses for
More information