1 Centre Hospitalier Universitaire et Psychiatrique de Mons-Borinage B-Flex Multifocal Dr Emmanuel Van Acker Belgium

2 Comparison of clinical outcomes and patient satisfaction after implantation of two different types of diffractive apodized IOLs: Bi-Flex M (based on PAD technology) FineVision (Micro F) trifocal diffractive IOL Prospective, randomized, observational study

3 Description * Value Bi Flex M () FineVision (MicroF) Optic & haptics material Hydrophilic acrylic (copolymer formed of 2-HEMA and OEMA) => 25% water content UV filter; Blue light filter ( nm) Refractive index 1.46 (when hydrated) Optic diameter 6 mm 6.15mm Overall diameter 13 mm mm IOL Single piece Single piece Technology Aspheric; Refractive/diffractive apodized; PAD technology Aspheric; trifocal; diffractive (2 diffractive arrays); apodized Type of haptics Double (Z-loop modified) Four loops haptics Haptic angulation 0 (posterior voltage) 5 Available power +10D to +35D +10 to + 35D Addition +1.75, , +3.5 Estimated Incision mm 1.8 A-Constant SRK II A-constant SRK-T *Data of FineVision IOL are taken from official scientific material (brochure; website) from company Physiol

4 Bi Flex M Technology Central 3.0 mm apodized diffractive structure Step heights decrease peripherally from microns +3.5D at lens plane equalling +2.7D at spectacle plane Outer refractive zone Aspheric (neutral approach)

5 Bi-Flex M () FineVision 7 rings Diffractive zone diameter: 3 mm 20 rings Diffractive zone diameter: full optic

6 STUDY DESIGN Prospective Randomly chosen IOL type for each patient Consent form Tenets of Declaration of Helsinki international Ethical committee (FEKI) Statistical analysis: Mann-Whitney-U test and independent t-test. Significance level was set up to 0,05. Analysis performed by IBM SPSS Statistics version 24.

7 MEASUREMENTS Metrovision Glare test Contrast sensitivity Pupillometry Standard tests Visual acuity (ETDRS) Biomicroscopy Defocus curves Visual Fct Questionnaire

8 Examination Test Protocol of the Study Randomly included patients Discussion, explanations Follow-up 12 months D1 D7 M1 M3 M6 M12 Medical history Pre-operative examination biometry UCDVA, UCIVA, UVNVA (monocular, binocular) ETDRS table (Decimal) Implantation of the IOL bilateral (interval min. 24 hours) Refraction, intraocular pressure Contrast sensitivity (Metrovision) Defocus curves Subjective satisfaction Spectacle independency Optic phenomena's (glare, halo..) Validated quality of vision questionnaire

9 Consecutive patients included 39 patients / 78 eyes 20 patients/ 40 eyes 19 patients / 38 eyes

10 64 Age of patients (49-71) 54 (47-65) 63 (49-71) 53 (47-65) Bi-Flex M FineVision 48 Mean Median There WERE STATISTICALLY SIGNIFICANT DIFFERENCES IN AGE of patients in between both groups

11 1,20 UCDVA, monocular 1,20 UCDVA, binocular 1,00 1,00 0,80 0,80 0,60 0,60 0,40 0,40 0,20 0,20 Preop D1 M1 M3 M6 Y1 Micro F M1 M3 M6 Y1 Micro F There were NOT STATISTICALLY SIGNIFICANT DIFFERENCES IN BINOCULAR VA

12 UCIVA, monocular UCIVA, binocular 1,20 1,20 1,00 1,00 0,80 0,80 0,60 * 0,60 0,40 0,40 0,20 0,20 Preop M1 M3 M6 Y1 M1 M3 M6 Y1 Micro F Micro F *UCIVA at M6 - statistically significant differences; All other UCIVA during other follow up periods NO STATISTIC DIFFERENCEs There were NOT STATISTICALLY SIGNIFICANT DIFFERENCES IN BINOCULAR VA

13 UCNVA, monocular UCNVA, binocular 1,20 1,20 1,00 1,00 0,80 * 0,80 0,60 0,60 0,40 0,40 0,20 0,20 Preop D1 M1 M3 M6 Y1 M1 M3 M6 Y1 Micro F Micro F *UCIVA at Y1 - statistically significant differences; All other UCIVA during other follow up periods NO STATISTIC DIFFERENCEs There were NOT STATISTICALLY SIGNIFICANT DIFFERENCES IN BINOCULAR VA

14 70 cm Defocus curve - 3M 1,50 1,00 0,50 +4,0 D +3,5 D +3,0 D +2,5 D +2,0 D +1,5 D +1,0 D +0,0 D -0,5 D -1,0 D -1,5 D -2,0 D -2,5 D -3,0 D -3,5 D Micro F Defocus curve - 6M 1,40 1,20 1,00 0,80 0,60 0,40 0,20 +4,0 D +3,5 D +3,0 D +2,5 D +2,0 D +1,5 D +1,0 D +0,0 D -0,5 D -1,0 D -1,5 D -2,0 D -2,5 D -3,0 D -3,5 D Micro F

15 70 cm 1,50 Defocus curve - 12M 1,00 0,50 +4,0 D +3,5 D +3,0 D +2,5 D +2,0 D +1,5 D +1,0 D +0,0 D -0,5 D -1,0 D -1,5 D -2,0 D -2,5 D -3,0 D -3,5 D Micro F There were NOT STATISTICALLY SIGNIFICANT DIFFERENCES in any points of the defocus curves during follow-up period In the area underneath the defocus curves during follow-up period

16 Emmétrope 1998

17 Emmétrope née 2000

18 B-Flex M

19 % of letters recognized % of letters recognized % pf letters recognized Glare [100 cd/m 2 luminance] Glare [5 cd/m 2 luminance] M 1..3M 3..6M 6..12M 12+M Postop time M 1..3M 3..6M 6..12M 12+M Postop time MicroF MicroF Glare [1 cd/m 2 luminance] M 1..3M 3..6M 6..12M 12+M Postop time MicroF

20

21 Contrast static, 1-3 M Postop 25, ,00 1 5,00 0,1 cpd 1,0 cpd 10,0 cpd 100,0 cpd MicroF Contrast static, 6-12 M Postop CONTRAST SENSITIVITY PHOTOPIC 25, ,00 1 5,00 0,1 cpd 1,0 cpd 10,0 cpd 100,0 cpd MicroF

22 Mesopic, 1-3 M Postop 25, ,00 1 5,00 0,1 cpd 1,0 cpd 10,0 cpd 100,0 cpd MicroF CONTRAST SENSITIVITY MESOPIC Mesopic, 6-12 M Postop 25, ,00 1 5,00 0,1 cpd 1,0 cpd 10,0 cpd 100,0 cpd MicroF

23 Overall satisfaction: 9.3/10 QUALITY OF VISION QUESTIONNAIRE

24 CONCLUSION The study showed similar clinical performance of trifocal Fine Vision IOL (Physiol) and PAD Bi-Flex M (Medicontur) IOLs. Contrast sensitivity, glare tests Refractive results & stability Visual acuities Satisfaction of the patients Defocus curves The study confirmed clinical trifocal performance of PAD Bi-Flex M Both IOLs were accepted by patients with high satisfaction All patients in both examined groups were glass independent

7 DO IT. A SAFER WAY TO TRIFOCALITY * : ELEVATED PHASE SHIFT (EPS) ** 7 DIFFRACTIVE RINGS FOR OPTIMAL LIGHT DISTRIBUTION AND LESS DISTURBANCE

7 DO IT. A SAFER WAY TO TRIFOCALITY * : ELEVATED PHASE SHIFT (EPS) ** 7 DIFFRACTIVE RINGS FOR OPTIMAL LIGHT DISTRIBUTION AND LESS DISTURBANCE A SAFER WAY TO TRIFOCALITY * : ELEVATED PHASE SHIFT (EPS) ** 7 DIFFRACTIVE RINGS FOR OPTIMAL LIGHT DISTRIBUTION AND LESS DISTURBANCE 7 DO IT. TRIFOCAL PERFORMANCE & GLASS INDEPENDENCY UNCOMPROMISED CONTRAST

More information

Dr. Magda Rau Eye Clinic Cham, Germany

Dr. Magda Rau Eye Clinic Cham, Germany 3 and 6 Months clinical Results after Implantation of OptiVis Diffractive-refractive Multifocal IOL Dr. Magda Rau Eye Clinic Cham, Germany Refractive zone of Progressive power for Far to Intermediate

More information

Improving Lifestyle Vision. with Small Aperture Optics

Improving Lifestyle Vision. with Small Aperture Optics Improving Lifestyle Vision with Small Aperture Optics The Small Aperture Premium Lens Solution The IC-8 small aperture intraocular lens (IOL) is a revolutionary lens that extends depth of focus by combining

More information

Quality of Vision With Multifocal Progressive Diffractive Lens: Two-Year Follow-up

Quality of Vision With Multifocal Progressive Diffractive Lens: Two-Year Follow-up Quality of Vision With Multifocal Progressive Diffractive Lens: Two-Year Follow-up Antonio Mocellin, MD & Matteo Piovella, MD CMA, Centro di Microchirurgia Ambulatoriale Monza (Milan) Italy Dr Piovella

More information

AT LISA tri 839MP and AT LISA tri toric 939MP from ZEISS The innovative trifocal IOL concept providing True Living Vision to more patients

AT LISA tri 839MP and AT LISA tri toric 939MP from ZEISS The innovative trifocal IOL concept providing True Living Vision to more patients Premium Trifocal MICS OVDs IOLs AT LISA tri 839MP and AT LISA tri toric 939MP from ZEISS The innovative trifocal IOL concept providing True Living Vision to more patients The moment you help your patients

More information

Maximum Light Transmission. Pupil-independent Light Distribution. 3.75D Near Addition Improved Intermediate Vision

Maximum Light Transmission. Pupil-independent Light Distribution. 3.75D Near Addition Improved Intermediate Vision Multifocal Maximum Light Transmission Pupil-independent Light Distribution Better Visual Quality Increased Contrast Sensitivity 3.75D Near Addition Improved Intermediate Vision Visual Performance After

More information

NEW. AT LISA tri 839MP and AT LISA tri toric 939MP from ZEISS The innovative trifocal IOL concept providing True Living Vision to more patients

NEW. AT LISA tri 839MP and AT LISA tri toric 939MP from ZEISS The innovative trifocal IOL concept providing True Living Vision to more patients Premium Trifocal MICS OVDs IOLs NEW AT LISA tri 839MP and AT LISA tri toric 939MP from ZEISS The innovative trifocal IOL concept providing True Living Vision to more patients Trifocal toric IOL The moment

More information

Multifocal IOL Basics

Multifocal IOL Basics Multifocal IOL Basics Types of Multifocal Designs REFRACTIVE Concentric zones: M-flex (Rayner) Segmented: LENTIS Mplus (Oculentis) DIFFRACTIVE Progressive: 677MY (Medicontur) Bifocal: IQ AcrySof ReSTOR

More information

József Győry. Veszprem, Hungary

József Győry. Veszprem, Hungary Long term functional and morphological outcomes and patient satisfaction after cataract surgery with BiFlex M implantation with / without posterior central circular capsulorhexis (PCCC) József Győry Veszprem,

More information

Evolution of Diffractive Multifocal Intraocular Lenses

Evolution of Diffractive Multifocal Intraocular Lenses Evolution of Diffractive Multifocal Intraocular Lenses Wavefront Congress February 24, 2007 Michael J. Simpson, Ph.D. Alcon Research, Ltd., Fort Worth, Texas Presentation Overview Multifocal IOLs two lens

More information

EDoF IOL. ZEISS AT LARA 829MP Next generation Extended Depth of Focus Intraocular Lens. NEW EDoF IOL from ZEISS

EDoF IOL. ZEISS AT LARA 829MP Next generation Extended Depth of Focus Intraocular Lens. NEW EDoF IOL from ZEISS EDoF IOL Next generation Extended Depth of Focus Intraocular Lens NEW EDoF IOL from ZEISS Introducing the next generation EDoF IOL with the widest range of focus.* ZEISS AT LARA The new premium lens from

More information

Multifocal Progressive Diffractive Lens to Improve Light Distribuition and Avoid Light Loss: Two Years Clinical Results

Multifocal Progressive Diffractive Lens to Improve Light Distribuition and Avoid Light Loss: Two Years Clinical Results Multifocal Progressive Diffractive Lens to Improve Light Distribuition and Avoid Light Loss: Two Years Clinical Results Matteo Piovella MD & Barbara Kusa MD CMA, Centro di Microchirurgia Ambulatoriale

More information

PROGRESSIVE VISION WITHIN FULL ACCOMMODATIVE RANGE

PROGRESSIVE VISION WITHIN FULL ACCOMMODATIVE RANGE PROGRESSIVE VISION WITHIN FULL ACCOMMODATIVE RANGE PROGRESSIVE VISION Progressive vision within full accomodative range 03 Suitable for sub 2 mm MICS 01 PAD Progressive- Apodized-Diffractive 02 Aspheric

More information

SEE BEYOND WITH FULLRANGE OPTICS. Developed by Hanita Lenses

SEE BEYOND WITH FULLRANGE OPTICS. Developed by Hanita Lenses SEE BEYOND WITH FULLRANGE OPTICS Developed by Hanita Lenses SEE beyond with FullRange optics FullRange optic lenses are proven, highlyreliable and safe intraocular lenses designed to provide a solution

More information

Special Publication: Ophthalmochirurgie Supplement 2/2009 (Original printed issue available in the German language)

Special Publication: Ophthalmochirurgie Supplement 2/2009 (Original printed issue available in the German language) Special Publication: Ophthalmochirurgie Supplement 2/2009 (Original printed issue available in the German language) LENTIS Mplus - The one -and and-only Non--rotationally Symmetric Multifocal Lens Multi-center

More information

Treatment of Presbyopia during Crystalline Lens Surgery A Review

Treatment of Presbyopia during Crystalline Lens Surgery A Review Treatment of Presbyopia during Crystalline Lens Surgery A Review Pierre Bouchut Bordeaux Ophthalmic surgeons should treat presbyopia during crystalline lens surgery. Thanks to the quality and advancements

More information

Financial Disclosure. Acufocus. Presbyopia Surgery. Inlay Concept 8/14/17. Presbyopia Correction: The Holy Grail of Ophthalmology

Financial Disclosure. Acufocus. Presbyopia Surgery. Inlay Concept 8/14/17. Presbyopia Correction: The Holy Grail of Ophthalmology Acufocus Financial Disclosure I have no financial interest in any subject presented Presbyopia Correction: The Holy Grail of Ophthalmology Presbyopia Surgery Inlay Concept First conceived in 1949 by Dr.

More information

ROTATIONAL STABILITY MAKES THE DIFFERENCE

ROTATIONAL STABILITY MAKES THE DIFFERENCE The Bi-Flex platform the proven platform of Excellence 01 Proven Stability less than 02 Optimal biomaterials 2 degrees long term rotation 03 Posterior Toric Lens surface with marks indicating the flat

More information

PATIENT SELECTION THE RIGHT PATIENT UNDERPROMISE AND OVERDELIVER THE PERFECT SPECTACLE FREE TREATMENT. Desires Less Dependence on glasses

PATIENT SELECTION THE RIGHT PATIENT UNDERPROMISE AND OVERDELIVER THE PERFECT SPECTACLE FREE TREATMENT. Desires Less Dependence on glasses Bilateral TECNIS MF versus Customized TECNIS MF - REZOOM Achieving Spectacle Independence THE PERFECT SPECTACLE FREE TREATMENT PATIENT SELECTION 1.ARE THEY INTERESTED IN BECOMING SPECTACLE FREE? 2.ARE

More information

NOW. Approved for NTIOL classification from CMS Available in Quar ter Diopter Powers. Accommodating. Aberration Free. Aspheric.

NOW. Approved for NTIOL classification from CMS Available in Quar ter Diopter Powers. Accommodating. Aberration Free. Aspheric. NOW Approved for NTIOL classification from CMS Available in Quar ter Diopter Powers Accommodating. Aberration Free. Aspheric. Accommodation Meets Asphericity in AO Merging Innovation & Proven Design The

More information

American National Standard for Ophthalmics. Extended Depth of Focus Intraocular Lenses

American National Standard for Ophthalmics. Extended Depth of Focus Intraocular Lenses January 23, 2018 rev. 7 ----------------------------------------------------------------------------------------------------------------------------- American National Standard (DRAFT) ANSI Z80.35 -----------------------------------------------------------------------------------------------------------------------------

More information

Diffractive Optics. Multifocal Lenses. Correction of Pseudophakic Presbyopia with Multifocal IOLs. Basic Designs

Diffractive Optics. Multifocal Lenses. Correction of Pseudophakic Presbyopia with Multifocal IOLs. Basic Designs Correction of Pseudophakic Presbyopia with Multifocal IOLs GEORGE H.H. BEIKO, B.M.,B.Ch.,FRCSC ST. CATHARINES, CANADA ASSIST PROF, MCMASTER UNIV george.beiko@sympatico.ca AMO Tecnis MFIOL Alcon ReSTOR

More information

NEW THE WORLD S FIRST AND ONLY SINUSOIDAL TRIFOCAL IOL

NEW THE WORLD S FIRST AND ONLY SINUSOIDAL TRIFOCAL IOL NEW THE WORLD S FIRST AND ONLY SINUSOIDAL TRIFOCAL IOL ALL TRIFOCAL IOLS ARE NOT THE SAME! Seamless Vision Near Intermediate Far Light Figure 1: Comparison of MTF Values 1,2 THE WORLD S FIRST AND ONLY

More information

Unique Aberration-Free IOL: A Vision that Patients

Unique Aberration-Free IOL: A Vision that Patients Unique Aberration-Free IOL: A Vision that Patients Can Appreciate An Aspheric Optic for Improved Quality of Vision n Traditional spherical IOLs create Bilateral implantation study spherical aberration

More information

Product Portfolio. Sulcoflex Pseudophakic Supplementary IOLs. Your skill. Our vision.

Product Portfolio. Sulcoflex Pseudophakic Supplementary IOLs. Your skill. Our vision. Product Portfolio Sulcoflex Pseudophakic Supplementary IOLs Your skill. Our vision. Sulcoflex Pseudophakic Supplementary IOLs For when compromise is not an option As a cataract and refractive surgeon,

More information

Product Portfolio. Sulcoflex Pseudophakic Supplementary IOLs

Product Portfolio. Sulcoflex Pseudophakic Supplementary IOLs Product Portfolio Sulcoflex Pseudophakic Supplementary IOLs Sulcoflex Pseudophakic Supplementary IOLs For when compromise is not an option As a cataract and refractive surgeon, achieving the best possible

More information

CONTENTS. HYDROPHILIC IOLs. Bi-Flex PIL-MA hydrophilic preloaded P / PY 677PT / PTY 677PMY 677PMTY. Bi-Flex HL...

CONTENTS. HYDROPHILIC IOLs. Bi-Flex PIL-MA hydrophilic preloaded P / PY 677PT / PTY 677PMY 677PMTY. Bi-Flex HL... Bi-Flex IOL RANGE CONTENTS HYDROPHILIC IOLs Bi-Flex PIL-MA hydrophilic preloaded... 1 677P / PY 677PT / PTY 677PMY 677PMTY Bi-Flex HL... 2 677AB / ABY Bi-Flex T... 3 677TA / TB 677TAY / TBY Bi-Flex M...

More information

Accommodating IOL s History and Clinical Management

Accommodating IOL s History and Clinical Management Accommodating IOL s History and Clinical Management Bausch & Lomb Surgical Aliso Viejo, CA Genesis of an Accommodating IOL 1 Observations with Plate IOLs Stuart Cumming 1989 Some plate haptic IOL patients

More information

Sulcoflex. For when perfection is the only option! Pseudophakic Sulcus Fixated Secondary IOLs. Sulcoflex Aspheric. Sulcoflex Toric

Sulcoflex. For when perfection is the only option! Pseudophakic Sulcus Fixated Secondary IOLs. Sulcoflex Aspheric. Sulcoflex Toric Sulcoflex Pseudophakic Sulcus Fixated Secondary IOLs Sulcoflex Aspheric Sulcoflex Toric Sulcoflex Multifocal For when perfection is the only option! Sulcoflex Pseudophakic Sulcus Fixated Secondary IOLs

More information

Raise your expectations. Deliver theirs.

Raise your expectations. Deliver theirs. 66 EXTENDED RANGE OF VISION MONOFOCAL-LIKE DISTANCE Raise your expectations. Deliver theirs. Now you can give your patients the best of both worlds with the first and only hybrid designed monofocal-multifocal

More information

Clinical Update for Presbyopic Lens Options

Clinical Update for Presbyopic Lens Options Clinical Update for Presbyopic Lens Options Gregory D. Searcy, M.D. Erdey Searcy Eye Group Columbus, Ohio The Problem = Spherical Optics Marginal Rays Spherical IOL Light Rays Paraxial Rays Spherical Aberration

More information

day night convinced supreme contrast sensitivity THE IOL FOR DAY & NIGHT

day night convinced supreme contrast sensitivity THE IOL FOR DAY & NIGHT day supreme contrast sensitivity night convinced THE IOL FOR DAY & NIGHT The IOL for DAY & NIGhT UnIQUE form and features Innovative blue light filtering Excellent quality of vision Maximum depth of focus

More information

EDOF-IOLs: Are they all the same?

EDOF-IOLs: Are they all the same? Gerd.Auffarth@med.uni-heidelberg.de www.ivcrc.com www.djapplelab.com EDOF-IOLs: Are they all the same? G. U. Auffarth International Vision Correction Research Centre (IVCRC), The David J. Apple International

More information

Clinical Evaluation 3-month Follow-up Report

Clinical Evaluation 3-month Follow-up Report Clinical Evaluation 3-month Follow-up Report Of SeeLens HP Intraocular Lens 27 December 2010 version 1.1 1of 16 Table of Contents TABLE OF CONTENTS... 1 OBJECTIVES... 2 EFFICACY AND SAFETY ASSESSMENTS...

More information

Prospective sual evaluation of apodized diffractive intraocular lenses

Prospective sual evaluation of apodized diffractive intraocular lenses See discussions, stats, and author profiles for this publication at: https://www.researchgate.net/publication/6251759 Prospective sual evaluation of apodized diffractive intraocular lenses ARTICLE in JOURNAL

More information

Retinal stray light originating from intraocular lenses and its effect on visual performance van der Mooren, Marie Huibert

Retinal stray light originating from intraocular lenses and its effect on visual performance van der Mooren, Marie Huibert University of Groningen Retinal stray light originating from intraocular lenses and its effect on visual performance van der Mooren, Marie Huibert IMPORTANT NOTE: You are advised to consult the publisher's

More information

Corneal Asphericity and Retinal Image Quality: A Case Study and Simulations

Corneal Asphericity and Retinal Image Quality: A Case Study and Simulations Corneal Asphericity and Retinal Image Quality: A Case Study and Simulations Seema Somani PhD, Ashley Tuan OD, PhD, and Dimitri Chernyak PhD VISX Incorporated, 3400 Central Express Way, Santa Clara, CA

More information

IOL Types. Hazem Elbedewy. M.D., FRCS (Glasg.) Lecturer of Ophthalmology Tanta university

IOL Types. Hazem Elbedewy. M.D., FRCS (Glasg.) Lecturer of Ophthalmology Tanta university IOL Types Hazem Elbedewy M.D., FRCS (Glasg.) Lecturer of Ophthalmology Tanta university Artificial intraocular lenses are used to replace the eye natural lens when it has been removed during cataract surgery.

More information

Crystalens AO: Accommodating, Aberration-Free, Aspheric Y. Ralph Chu, MD Chu Vision Institute Bloomington, MN

Crystalens AO: Accommodating, Aberration-Free, Aspheric Y. Ralph Chu, MD Chu Vision Institute Bloomington, MN Crystalens AO: Accommodating, Aberration-Free, Aspheric Y. Ralph Chu, MD Chu Vision Institute Bloomington, MN Financial Disclosure Advanced Medical Optics Allergan Bausch & Lomb PowerVision Revision Optics

More information

Choices and Vision. Jeffrey Koziol M.D. Friday, December 7, 12

Choices and Vision. Jeffrey Koziol M.D. Friday, December 7, 12 Choices and Vision Jeffrey Koziol M.D. How does the eye work? What is myopia? What is hyperopia? What is astigmatism? What is presbyopia? How the eye works Light rays enter the eye through the clear cornea,

More information

Choices and Vision. Jeffrey Koziol M.D. Thursday, December 6, 12

Choices and Vision. Jeffrey Koziol M.D. Thursday, December 6, 12 Choices and Vision Jeffrey Koziol M.D. How does the eye work? What is myopia? What is hyperopia? What is astigmatism? What is presbyopia? How the eye works How the Eye Works 3 How the eye works Light rays

More information

Correlation of pupil size with visual acuity and contrast sensitivity after implantation of an apodized diffractive intraocular lens

Correlation of pupil size with visual acuity and contrast sensitivity after implantation of an apodized diffractive intraocular lens ARTICLE Correlation of pupil size with visual acuity and contrast sensitivity after implantation of an apodized diffractive intraocular lens José F. Alfonso, MD, PhD, Luis Fernández-Vega, MD, PhD, M. Begoña

More information

RayOne Hydrophobic IOL. New design. New standard MADE IN UK

RayOne Hydrophobic IOL. New design. New standard MADE IN UK RayOne Hydrophobic IOL New design. New standard MADE IN UK Setting new standards since 1949 About Rayner When Sir Harold Ridley designed the world s first IOL in 1949, he chose Rayner to manufacture this

More information

*Simulated vision. **Individual results may vary and are not guaranteed. Visual Performance When It s Needed Most

*Simulated vision. **Individual results may vary and are not guaranteed. Visual Performance When It s Needed Most Simulated vision. Individual results may vary and are not guaranteed. Visual Performance When It s Needed Most The aspheric design of the AcrySof IQ IOL results in improved clarity and image quality. The

More information

Forget Most Everything! The Surgical Management of Presbyopia 2/23/2016. Refraction vs. Diffraction. Presbyopic IOL s Patient Expectations

Forget Most Everything! The Surgical Management of Presbyopia 2/23/2016. Refraction vs. Diffraction. Presbyopic IOL s Patient Expectations The Surgical Management of Presbyopia Presbyopic IOL s 2011 B I L L T U L L O, O D Patient Expectations What they say is I want to be able to read The Center of a Presbyope s World What they want is Accommodation

More information

Financial disclosure. Alcon, Zeiss, J&J AMO, Physiol, Thea, Allergan, Santen, Dompe, Cutting Edge) Race for Progress!

Financial disclosure. Alcon, Zeiss, J&J AMO, Physiol, Thea, Allergan, Santen, Dompe, Cutting Edge) Race for Progress! Financial disclosure Alcon, Zeiss, J&J AMO, Physiol, Thea, Allergan, Santen, Dompe, Cutting Edge) Race for Progress! What is new : to pay for progress? 4 properties Asphericity (Q factor) correlated to

More information

Glistening-Free Hydrophobic Acrylic IOL. Glistening-Free Hydrophobic Acrylic IOL

Glistening-Free Hydrophobic Acrylic IOL. Glistening-Free Hydrophobic Acrylic IOL Glistening-Free Hydrophobic Acrylic IOL Proprietary Polymer Composition Packaged Dry UD Aspheric Optic Optimized Refractive Index All SquareTM Enhanced Edge Largest Diopter Range -05.00D to 42.00D Modified

More information

THE ASPHERIC PRELOADED INJECTION

THE ASPHERIC PRELOADED INJECTION New from STAAR for Safe and Easy Implantation THE ASPHERIC PRELOADED INJECTION S Y S T E M PRELOADED INJECTION SYSTEM FOR SIMPLE AND EASY IOL DELIVERY SAFE The KS3-Ai features an aspheric IOL preloaded

More information

Multifocal Intraocular Lenses for the Treatment of Presbyopia: Benefits and Side-effects

Multifocal Intraocular Lenses for the Treatment of Presbyopia: Benefits and Side-effects Published on Points de Vue International Review of Ophthalmic Optics () Home > Multifocal Intraocular Lenses for the Treatment of Presbyopia: Benefits and Side-effects Multifocal Intraocular Lenses for

More information

Roadmap to presbyopic success

Roadmap to presbyopic success Roadmap to presbyopic success Miltos O Balidis MD, PhD, FEBOphth, ICOphth Early experience with Presbyopic correction 2003 Binocular Distance-Corrected Intermediate and Near Vision Binocular Distance-Corrected

More information

COMPARISON OF THE MEDICONTUR 860FAB

COMPARISON OF THE MEDICONTUR 860FAB COMPARISON OF THE MEDICONTUR 860FAB HYDROPHOBIC IOL AND THE ACRYSOF IQ LONG TERM FOLLOW UP Péter Vámosi MD, Amanda Argay MD, Zsófia Rupnik MD, János Fekete Péterfy Sándor Hospital Budapest, Hungary PREFERENCE

More information

Comparison between clinical results of two diffractive multifocal lenses with the same platform but different additions

Comparison between clinical results of two diffractive multifocal lenses with the same platform but different additions ARTICLE Comparison between clinical results of two diffractive multifocal lenses with the same platform but different additions Francisco Poyales, MD 1 ; Nuria Garzón, OD, MSc 1 ; Pedro Caro, MD 1 ; Oscar

More information

Wearable see-thru binocular simulator of multifocal and monovision presbyopic corrections

Wearable see-thru binocular simulator of multifocal and monovision presbyopic corrections Wearable see-thru binocular simulator of multifocal and monovision presbyopic corrections Susana Marcos, Aiswaryah Radhakrishnan, Maria Viñas, Clara Benedi, Sara Aissa7, Enrique Gambra, Daniel Pascual,

More information

Patient information. Your options for cataract treatment Enjoy clear vision at all distances with multifocal IOLs

Patient information. Your options for cataract treatment Enjoy clear vision at all distances with multifocal IOLs Patient information Your options for cataract treatment Enjoy clear vision at all distances with multifocal IOLs Bring your vision into focus Good vision is a major contributor to the quality of life.

More information

Optical Characteristics of Next Generation Dual Optic IOL

Optical Characteristics of Next Generation Dual Optic IOL Optical Characteristics of Next Generation Dual Optic IOL Scott Evans, MD Sanjeev Kasthurirangan, PhD Val Portney, PhD Financial Disclosures Scott Evans is an employee of Abbott Medical Optics Inc. Sanjeev

More information

Ocular Scatter. Rayleigh Scattering

Ocular Scatter. Rayleigh Scattering Ocular Scatter The are several sources of stray light in the eye including the cornea, transmission through the iris and the crystalline lens. Cornea tends to have Rayleigh Scatter Lens follows inverse

More information

I N M A D E F R A N C E. Hydrophobic monofocal NEW QUALITY SAFETY STABILITY TECHNICAL BROCHURE

I N M A D E F R A N C E. Hydrophobic monofocal NEW QUALITY SAFETY STABILITY TECHNICAL BROCHURE ENGINEERED AND M A D E I N F R A N C E Hydrophobic monofocal NEW QUALITY SAFETY STABILITY TECHNICAL BROCHURE Genesis, is a new hydrophobic intraocular lens developed and manufactured by CUTTING EDGE to

More information

Aberrations Before and After Implantation of an Aspheric IOL

Aberrations Before and After Implantation of an Aspheric IOL Ocular High Order Aberrations Before and After Implantation of an Aspheric IOL Fabrizio I. Camesasca, MD Massimo Vitali, Orthoptist Milan, Italy I have no financial interest to disclose Wavefront Measurement

More information

Design and qualification of a diffractive trifocal optical profile for intraocular lenses

Design and qualification of a diffractive trifocal optical profile for intraocular lenses LABORATORY SCIENCE Design and qualification of a diffractive trifocal optical profile for intraocular lenses Damien Gatinel, MD, PhD, Christophe Pagnoulle, PhD, Yvette Houbrechts, PhD, Laure Gobin, PhD

More information

Soft CL Multifocals Design and Fitting. Soft Multifocal Lens Designs. Issues Surrounding Multifocals. Blur Interpretation. Simultaneous Vision Designs

Soft CL Multifocals Design and Fitting. Soft Multifocal Lens Designs. Issues Surrounding Multifocals. Blur Interpretation. Simultaneous Vision Designs Soft CL Multifocals Design and Fitting Mark Andre, FAAO Associate Professor of Optometry Pacific University Mark Andre, FAAO is affiliated with CooperVision, as a consultant. Issues Surrounding Multifocals

More information

MINI WELL A Better Vision

MINI WELL A Better Vision A Sponsored Supplement From MINI WELL A Better Vision Highlights from the Milan 2017 SIFI User Meeting Panel Giovanni Alessio Gerd U. Auffarth Andrea Bedei Roberto Bellucci Claudio Carbonara Marko Hawlina

More information

Maximising Treatment Outcomes with Premium IOL Technology. Saturday 13 September 2014 XXXII Congress of the ESCRS London, UK.

Maximising Treatment Outcomes with Premium IOL Technology. Saturday 13 September 2014 XXXII Congress of the ESCRS London, UK. Supplement February 2015 Maximising Treatment Outcomes with Premium IOL Technology Saturday 13 September 2014 XXXII Congress of the ESCRS London, UK Sponsored by Introduction Thanks to advances in lens

More information

Multifocal and Accommodative

Multifocal and Accommodative What is an IOL? An intraocular lens (or IOL) is a tiny, artificial lens for the eye. It replaces the eye's natural lens. Retina Cornea Lens Macula The eye's normally clear lens bends (refracts) light rays

More information

The complete choice in refractive lens solutions

The complete choice in refractive lens solutions The complete choice in refractive lens solutions The VeriFlex phakic IOL is part of Advanced Medical Optics range of high-contrast, high-quality refractive lens solutions. In addition to excellent training

More information

CONSISTENT ADVANCES IN CATARACT SURGICAL

CONSISTENT ADVANCES IN CATARACT SURGICAL Evaluation of the Aspheric Tecnis Multifocal Intraocular Lens: One-Year Results from the First Cohort of the Food and Drug Administration Clinical Trial MARK PACKER, Y. RALPH CHU, KEVIN L. WALTZ, ERIC

More information

Visual function after bilateral implantation of apodized diffractive aspheric multifocal intraocular lenses with a D3.0 D addition

Visual function after bilateral implantation of apodized diffractive aspheric multifocal intraocular lenses with a D3.0 D addition ARTICLE Visual function after bilateral implantation of apodized diffractive aspheric multifocal intraocular lenses with a D3.0 D addition Thomas Kohnen, MD, Rudy Nuijts, MD, Pierre Levy, MD, Eduard Haefliger,

More information

Visual Outcomes of Two Aspheric PCIOLs: Tecnis Z9000 versus Akreos AO

Visual Outcomes of Two Aspheric PCIOLs: Tecnis Z9000 versus Akreos AO Visual Outcomes of Two Aspheric PCIOLs: Tecnis Z9000 versus Akreos AO Ahmad-Reza Baghi, MD; Mohammad-Reza Jafarinasab, MD; Hossein Ziaei, MD; Zahra Rahmani, MD Shaheed Beheshti Medical University, Tehran,

More information

Long-term quality of vision is what every patient expects

Long-term quality of vision is what every patient expects Long-term quality of vision is what every patient expects Innovative combination of HOYA technologies provides: 1-piece aspheric lens with Vivinex hydrophobic acrylic material Unique surface treatment

More information

Customized intraocular lenses

Customized intraocular lenses Customized intraocular lenses Challenges and limitations Achim Langenbucher, Simon Schröder & Timo Eppig Customized IOL what does this mean? Aspherical IOL Diffractive multifocal IOL Spherical IOL Customized

More information

Clinical Evaluation 3-month Follow-up Report

Clinical Evaluation 3-month Follow-up Report Clinical Evaluation 3-month Follow-up Report Of SeeLens AF Intraocular Lens 30 June 2010 version 1.1 1 of 21 Table of Contents: Objectives 2 Medical device specification and administration 4 Methods 9

More information

NON-LINEAR ASPHERIC ABLATION PROFILE FOR PRESBYOPIC CORNEAL TREATMENT USING THE MEL80/90 AND CRS MASTER PRESBYOND MODULE

NON-LINEAR ASPHERIC ABLATION PROFILE FOR PRESBYOPIC CORNEAL TREATMENT USING THE MEL80/90 AND CRS MASTER PRESBYOND MODULE NON-LINEAR ASPHERIC ABLATION PROFILE FOR PRESBYOPIC CORNEAL TREATMENT USING THE MEL80/90 AND CRS MASTER PRESBYOND MODULE Dan Z Reinstein, MD MA(Cantab) FRCSC DABO FRCOphth FEBO 1,2,3,4 Timothy J Archer,

More information

Contrast Sensitivity after Refractive Lens Exchange with A Multifocal Diffractive Aspheric Intraocular Lens

Contrast Sensitivity after Refractive Lens Exchange with A Multifocal Diffractive Aspheric Intraocular Lens Contrast Sensitivity after Refractive Lens Exchange with A Multifocal Diffractive Aspheric Intraocular Lens Teresa Ferrer-Blasco, PhD Santiago García-Lázaro, PhD César Albarrán-Diego, MSc 3 Lurdes Belda-Salmerón,

More information

WHY EDOF INTRAOCULAR LENSES? FOR EXCELLENT VISION QUALITY TO SUPPORT AN ACTIVE LIFESTYLE PATIENT INFORMATION. Cataract treatment

WHY EDOF INTRAOCULAR LENSES? FOR EXCELLENT VISION QUALITY TO SUPPORT AN ACTIVE LIFESTYLE PATIENT INFORMATION. Cataract treatment WHY EDOF INTRAOCULAR LENSES? FOR EXCELLENT VISION QUALITY TO SUPPORT AN ACTIVE LIFESTYLE PATIENT INFORMATION Cataract treatment OK, I HAVE A CATARACT. NOW WHAT? WE UNDERSTAND YOUR CONCERNS WE CAN HELP.

More information

Not everyone can do this. Introducing RayOne with patented Lock & Roll TM technology for the smallest fully preloaded IOL incision

Not everyone can do this. Introducing RayOne with patented Lock & Roll TM technology for the smallest fully preloaded IOL incision Not everyone can do this Introducing RayOne with patented Lock & Roll TM technology for the smallest fully preloaded IOL incision RayOne fully preloaded IOL injection system, designed to deliver without

More information

Assessing Visual Quality With the Point Spread Function Using the NIDEK OPD-Scan II

Assessing Visual Quality With the Point Spread Function Using the NIDEK OPD-Scan II Assessing Visual Quality With the Point Spread Function Using the NIDEK OPD-Scan II Edoardo A. Ligabue, MD; Cristina Giordano, OD ABSTRACT PURPOSE: To present the use of the point spread function (PSF)

More information

FOR EXCELLENT VISION QUALITY TO SUPPORT AN ACTIVE LIFESTYLE

FOR EXCELLENT VISION QUALITY TO SUPPORT AN ACTIVE LIFESTYLE WHY EDOF INTRAOCULAR LENSES? FOR EXCELLENT VISION QUALITY TO SUPPORT AN ACTIVE LIFESTYLE PATIENT INFORMATION Cataract treatment Insert your logo here 2 OK, I HAVE A CATARACT. NOW WHAT? WE UNDERSTAND YOUR

More information

The Appearance of Images Through a Multifocal IOL ABSTRACT. through a monofocal IOL to the view through a multifocal lens implanted in the other eye

The Appearance of Images Through a Multifocal IOL ABSTRACT. through a monofocal IOL to the view through a multifocal lens implanted in the other eye The Appearance of Images Through a Multifocal IOL ABSTRACT The appearance of images through a multifocal IOL was simulated. Comparing the appearance through a monofocal IOL to the view through a multifocal

More information

Today s subject Auto Refractometer & Auto Ref / Keratometer AR-1 & ARK-1

Today s subject Auto Refractometer & Auto Ref / Keratometer AR-1 & ARK-1 Webinar for optical products Today s subject Auto Refractometer & Auto Ref / Keratometer AR-1 & ARK-1 2013/04/16 International Sales Development Dept., International Div. More than Auto Refract/Keratometer

More information

Disclosures. Opportunities for speciality contact lenses in the multifocal market. Principals. Prof James Wolffsohn

Disclosures. Opportunities for speciality contact lenses in the multifocal market. Principals. Prof James Wolffsohn Disclosures Opportunities for speciality contact lenses in the multifocal market Prof James Wolffsohn Ophthalmic Research Group, Life and Health Sciences, Aston University, Birmingham, UK Vested Interest

More information

Trust your eyes. Presbyopic treatment methods on the cornea. PresbyMAX Decision criteria and patient s acceptance

Trust your eyes. Presbyopic treatment methods on the cornea. PresbyMAX Decision criteria and patient s acceptance Trust your eyes. Directory Presbyopic treatment methods on the cornea PresbyMAX The Principle PresbyMAX Expectations and Key Factors PresbyMAX Decision criteria and patient s acceptance PresbyMAX Upcoming

More information

Refractive Power / Corneal Analyzer. OPD-Scan III

Refractive Power / Corneal Analyzer. OPD-Scan III Refractive Power / Corneal Analyzer OPD-Scan III Comprehensive Vision Analysis and NIDEK, a global leader in ophthalmic and optometric equipment, has created the OPD-Scan III, the third generation aberrometer

More information

CATARACT SURGERY AND DEPTH OF FIELD (D.O.F.)

CATARACT SURGERY AND DEPTH OF FIELD (D.O.F.) Prof.Paolo Vinciguerra, M.D. 1, 2 Antonio Calossi 4 Riccardo Vinciguerra, M.D. 1-3 1 Humanitas University 1 Humanitas Clinical and Research Center IRCS 2 Columbus, Ohio State University 3 University of

More information

OCULUS Binoptometer 4P

OCULUS Binoptometer 4P OCULUS Binoptometer 4P Professional Vision Testing Device We focus on progress Innovative Test presentation on a high-resolution color display Visual acuity test Landolt rings conform to DIN EN ISO 8596

More information

(495) (495)

(495) (495) МЕДТЕХНИКА-СТОЛИЦА (495) 902-59-26 (495) 518-55-99 127 238, г. Москва, Дмитровское ш. 85 ATLAS Corneal Topography Product Overview Model 9000 ATLAS Model 9000 Overview Next-generation corneal topography

More information

In vitro comparative optical bench analysis of a spherical and aspheric optic design of the same IOL model

In vitro comparative optical bench analysis of a spherical and aspheric optic design of the same IOL model Tandogan et al. BMC Ophthalmology (2017) 17:9 DOI 10.1186/s12886-017-0407-5 RESEARCH ARTICLE Open Access In vitro comparative optical bench analysis of a spherical and aspheric optic design of the same

More information

ASPIRA PUBLICATION LIST

ASPIRA PUBLICATION LIST ASPIRA PUBLICATION LIST ASPIRA-aA / MC 6125 AS PR2 PR3 Eppig T, Scholz K, Löffler A, et al. Effect of decentration and tilt on the image quality of aspheric intraocular lens designs in a model eye J Cataract

More information

Easy to identify: The color-coded forceps and scissors make identification during September September September 2016

Easy to identify: The color-coded forceps and scissors make identification during September September September 2016 Surgical Instruments Astigmatism neutral incision, less trauma: Thanks to a tube diameter of just 23 Gauge, the final incision size is only 1 mm. Unique vertical cutting: Scissors designed for enlarging

More information

OPTOMETRY RESEARCH PAPER. Visual performance comparison between contact lens-based pinhole and simultaneous vision contact lenses

OPTOMETRY RESEARCH PAPER. Visual performance comparison between contact lens-based pinhole and simultaneous vision contact lenses C L I N I C A L A N D E X P E R I M E N T A L OPTOMETRY RESEARCH PAPER Visual performance comparison between contact lens-based pinhole and simultaneous vision contact lenses Clin Exp Optom 2013; 96: 46

More information

THE XTRAFOCUS IS AN ELEGANT SOLUTION TO COMPLEX CASES.

THE XTRAFOCUS IS AN ELEGANT SOLUTION TO COMPLEX CASES. XtraFocus THE XTRAFOCUS IS AN ELEGANT SOLUTION TO COMPLEX CASES. CONTENT Based on the well-established principle of pinhole optics, this intraocular implant represents an innovative alternative for the

More information

Preloaded. PreciSAL. EZ Toric

Preloaded. PreciSAL. EZ Toric Preloaded PreciSAL EZ Toric Experience the beauty with new vision Make a difference every time 1 Why you should choose MBI 3 Our vision is clear 4 PreciSAL quality 5 MTF of PreciSAL 7 Optical precision

More information

Comparison of contrast sensitivity and color discrimination after clear and yellow intraocular lens implantation

Comparison of contrast sensitivity and color discrimination after clear and yellow intraocular lens implantation J CATARACT REFRACT SURG - VOL 31, SEPTEMBER 2005 Comparison of contrast sensitivity and color discrimination after clear and yellow intraocular lens implantation Antonio Rodríguez-Galietero, MD, PhD, FEBO,

More information

LEAVE A LEGACY OF VISUAL FREEDOM. TECNIS PRESBYOPIA-CORRECTING IOLs

LEAVE A LEGACY OF VISUAL FREEDOM. TECNIS PRESBYOPIA-CORRECTING IOLs LEAVE A LEGACY OF VISUAL FREEDOM. TECNIS PRESBYOPIA-CORRECTING IOLs The TECNIS Portfolio of presbyopia-correcting IOLs empowers you to hand-select a lens that can deliver the visual freedom your patients

More information

Principles and clinical applications of ray-tracing aberrometry (Part II)

Principles and clinical applications of ray-tracing aberrometry (Part II) UPDATE/REVIEW Principles and clinical applications of ray-tracing aberrometry (Part II) Alfredo Castillo Gómez, MD, PhD 1 ; Antonio Verdejo del Rey, OD 2 ; Carlos Palomino Bautista, MD 3 ; Ana Escalada

More information

Advances in the design and

Advances in the design and A look into the IOL space BY R MCNEIL Advances in the design and performance of intraocular lenses (IOLs) continue to be driven by demand for better outcomes, presbyopia correction and spectacle independence,

More information

The Miracle of Pi in Eye. Rajesh Khanna, MD

The Miracle of Pi in Eye. Rajesh Khanna, MD The Miracle of Pi in Eye Rajesh Khanna, MD Copyright 2013 Rajesh Khanna, MD All rights reserved. Pi in eye DEDICATION This book is dedicated to all my patients who placed their faith in me and trusted

More information

FOR PRECISE ASTIGMATISM CORRECTION.

FOR PRECISE ASTIGMATISM CORRECTION. WHY TORIC INTRAOCULAR LENSES? FOR PRECISE ASTIGMATISM CORRECTION. PATIENT INFORMATION Cataract treatment OK, I HAVE A CATARACT. NOW WHAT? WE UNDERSTAND YOUR CONCERNS WE CAN HELP. Dear patient, Discovering

More information

LENSES. Materials, Types and Treatments. Mary E. Schmidt, ABOC, CPO

LENSES. Materials, Types and Treatments.  Mary E. Schmidt, ABOC, CPO LENSES Materials, Types and Treatments www.eyesystems.info Mary E. Schmidt, ABOC, CPO mary@eyesystems.info Single Vision Spherical in design All purpose, single focus, may be sphere or cylinder Rx s Aspheric

More information

ATLAS Corneal Topography System

ATLAS Corneal Topography System ATLAS Corneal Topography System Simply accurate for maximum productivity Model 9000 The New ATLAS Take your practice to the next level Carl Zeiss Meditec has taken the world s leading corneal topography

More information

LENSES. Materials, Types and Treatments. Single Vision. Aspherical Lens Forms

LENSES. Materials, Types and Treatments. Single Vision. Aspherical Lens Forms LENSES Materials, Types and Treatments www.eyesystems.info Mary E. Schmidt, ABOC, CPO mary@eyesystems.info Single Vision Spherical in design All purpose, single focus, may be sphere or cylinder Rx s Aspheric

More information

Visual Performance with Multifocal Intraocular Lenses

Visual Performance with Multifocal Intraocular Lenses Visual Performance with Multifocal Intraocular Lenses Mesopic Contrast Sensitivity under Distance and Near Conditions Robert Montés-Micó, OD, MPhil, 1 Enrique España, MD, PhD, 1,2 Inmaculada Bueno, OD,

More information