WITec Alpha 300R Quick Operation Summary October 2018
|
|
- Michael Watts
- 5 years ago
- Views:
Transcription
1 WITec Alpha 300R Quick Operation Summary October 2018 This document is frequently updated if you feel information should be added, please indicate that to the facility manager (currently Philip Carubia, B57 Bard Hall, office and cell: ). All procedures are subject to change. If you have any questions about the operation of the instrument, do not take any risks first contact the facility manager: He has his cell phone with him at all times. Reservations and Enabling on Coral: The WITec 300R Raman microscope is on the CCMR Coral equipment reservation and enabling system. Users are allowed to reserve the instrument for as much time as they need. However users who reserve time and do not cancel it in advance will be charged; abuse of the reservation system can result in suspension of CCMR facility privileges. You can access Coral either from your laptop or from the Coral computer in Bard SB30. Safety: This instrument uses Class IIIb lasers, so please be alert to the safety issues you learned in the EH&S laser safety course. Use of laser safety eyewear is not required but common sense is. Please think twice and act once. Logbook: Record the date, your name, and hours of usage. Comment on problems. Keeping lab orderly: Please dispose of any glass slides that you use into the glass disposal container on the floor near the base of the system. Also dispose of wipes, tape, etc. when you are done with them. About the WITec Raman system The WITec Raman is an advanced confocal Raman microscope that combines fast imaging, high spectral sensitivity and spatial resolution with excellent analysis software into a system designed around imaging. The system has high confocality and boasts a minimum depth slice of ~350 nm. This enables the user to take 3D Raman images with sub-micron resolution. The system consists of three main parts: lasers, microscope, and spectrometers. Lasers: The system currently has two lasers 532 nm and 785 nm. Both lasers are located on the benchtop next to the computer tower. Laser light going both from the laser to the microscope and from the microscope to the spectrometer is fiber coupled. This provides several advantages: First, the confocality comes from the aperture created by focusing on the skinny fiber. Second, the fibers provide high throughput over long distances. Third, the fiber protects users from laser light. The fiber coupler for the laser is located on the front side of the laser next to the computer tower. The fiber coupler is delicate and sensitive. Please DO NOT BUMP OR TRY TO ADJUST THE FIBER COUPLERS! The laser is pictured below. The user will use three things on the laser. 1) Attenuator: The attenuator is the small micrometer knob on the front of the laser located between the laser body and the fiber coupler. Users will use the attenuator in conjunction with the laser power meter to adjust the laser fluence incident on the sample. Turning the attenuator clockwise decreases the laser power and counterclockwise increases the laser power. 2) Shutter: The shutter is the silver knurled knob located just behind the attenuator on the laser body. The shutter is open when the slot in top of the knob is aligned with the fiber axis and closed when the slot is perpendicular to the fiber axis. The shutter should be either open or closed; there is no intermediate setting. 3) Power: Both lasers can be turned on and off using the key on the back side of the laser body. Turning the key 90 clockwise will turn the laser on and 90 counter clockwise will turn it off. For very stable power the laser should be given ~5 minutes of warmup time. Page 1 of 7
2 Image1: laser body with attenuator, shutter and power key positions. Microscope: Labelled parts and pieces of the microscope are shown in the image below with descriptions from the bottom up. X-Y stage: The sample stage is automated in X and Y directions and is controlled either by the software or the X-box controller. The Z control actually raises the entire microscope head. Pressing up on the controller makes the gap between the objective and the sample get bigger. To protect the objective, use caution when moving the stage or microscope head. Objective turret: the objective turret can house up to 6 objectives. There are five standard objectives though the majority of spectra will be acquired using either the 50X LWD or the 100X. Users will use the 100X objective ONLY for very flat samples. Do not use this objective for powders, liquids, or samples that have long range curvature or surface roughness that is larger than 20 µm Users may use the 50X LWD for all other samples. Bright field/raman selector: BF (Bright field) position on left is for white light imaging and the right position is for Raman Imaging. F-stop and Aperture: Use the F-stop to help focus on a difficult sample. Use the aperture to increase visible light contrast or to make the software slider more sensitive. Visible light analyzer: Analyzer for viewing samples in a crossed polarized configuration. Pull knob toward front of scope to put the analyzer in beam path. Remove the analyzer for Raman imaging. Page 2 of 7
3 Camera selector: Directs light to the camera when in the out position. True surface: the True Surface function allows the software to track with the surface of uneven samples. Pull the knob out to allow the true surface laser to be incident on the sample surface (True surface also requires activation and adjustment in the software). True surface will only function with a magnification > 20X. True surface may have trouble focusing on rough samples or samples with large steps. Laser power meter: Pull the lever out to direct light to the meter. The meter reader is located on the benchtop to the right of the microscope. The power for the meter reader is located on the left side of the meter. Rayleigh filter: Turn wheel to appropriate laser. Calibration source: This function is only used for calibrating spectra with an external calibration source. If you have questions about this capability please contact the facility manager. Spectrometer selection: Pull knob for appropriate laser wavelength. Be sure that the knob for the unused spectrometer is pushed in. Spectrometers: The two spectrometers are located on the blue table to the left of the microscope. Cameras for both spectrometers operate at sub-ambient conditions. When starting the software there is a cooling step that takes about 5 minutes to complete before the system is ready to acquire spectra. Spectrometers and options are as follows: UHTS600: Visible light spectrometer optimized for best sensitivity between 450nm and 750nm. 600mm focal length. Three grating options: 300l/mm, 1200l/mm and 1800l/mm. UHTS400: NIR spectrometer optimized for best sensitivity between 630nm and 1100nm. 400mm focal length. Two grating options: 300l/mm and 1200l/mm. No specific spectrometer selection is required. Setting the microscope appropriately for the laser that you will be using will automatically select the appropriate spectrometer. NOTE: The spectrometers are sensitive! Please do not use the spectrometers as a table for your samples! The spectrometers should always be on. If they are off they should only be turned on by the facility manager. Page 3 of 7
4 Software: The software that controls the system is control5. Open it from the icon on the desktop. There are five main windows. Control, WITec video control, Stitching image, Project manager, and Messages. WITec Video Control: is the main interface for stage and microscope control. Come here for objective selection, true surface interface, light intensity, ETC. Stitching image: stitched and single images will display in separate windows that can be used to navigate the sample when in Raman mode. Project manager: All data will display in project manager including Raman maps and single white light images. Control: Is the main interface for image and spectral acquisition and is described in further detail below. Page 4 of 7
5 Control functions: Control is the main interface for a number of functions in the Scan table: Scan table provides adjustment for the Z-axis coordinate system. Only make changes to scan table with the permission of the facility manager as the can lead to greater probability of crashing objectives. Sample positioning: Sample positioning to controls the X-Y stage. Use it to: Move to positions Reset the coordinate system to zero (set zero) Move to specific positions in the stitching image window (listen position). Spectrograph 1: Use Spectrograph to control spectrometer functions. Spectrograph will control the spectrometer specified under configurations. Choose grating type under grating. Center wavelength will center the specified wavelength on the detector also centering it in the acquired spectrum. Spectral unit can be changed to the users preferred unit Spectral center will center the specified spectral unti on the detector also centering it in the acquired spectrum. Oscilliscope: The oscilloscope function will allow a user to view a real-time Raman spectrum of the sample. This can be very helpful for maximizing signal as well as looking for regions of interest. Image stitching: Use image stitching to join multiple images into one larger image. Specify stitched geometry by specifying area and center or through listen position. A larger image taken with a lower magnification objective is required to use the listen position option. Large area scan: The large area scan function is for Raman mapping. Set scan method. Continuous is typical and fastest. Set Geometry either by specifying area and center or through listen position. Specify spectral resolution by setting points/line and lines/image Page 5 of 7
6 Quick steps for taking a measurement: The following describes the alignment of the alpha300 system in order to obtain a confocal Raman image, perform a line scan, a time series or capture a single Raman spectrum. The first of the following steps describe the procedure for focusing the microscope on the sample using white light illumination followed by the focusing of laser radiation. 1. Power up the computer and start WITec Control. Select the appropriate Raman mode for the laser that you will be using from the Configurations-menu. The CCD camera will be cooled to its minimum stable temperature automatically 2. Place the shutter into the laser beam path 3. Turn the laser power on by turning the key on the back 90 clockwise. 4. Mount the sample on the scanning stage. 5. Rotate the microscope turret until an appropriate objective is in the working position. Make sure you use the microscope objective in the proper way (e.g. use a cover slip if a cover slip corrected objective is used). 6. Pull out the video rod to direct light to the color video camera. 7. Move the Raman/bright field (R/BF) slider to the bright field position. 8. Adjust the illumination to the required level using the illumination menu item in the Control Window or with the controller up or down arrow. 9. Observe the image of the color video camera on the computer monitor using the Video Control Window in the WITec Control software. 10. Focus on the surface of your sample with the Microscope Z stage. This can be done in two different ways: a. Using the Z microscope control in the Graphic Control Window. Clicking on the arrows will move the stage in the indicated direction. b. Using the remote control with the Z Microscope selected as the controlled device. Using the left joystick, the Z-focusing-stage can be moved up or down. c. Notes on focusing the microscope: i. If possible, move the objective initially away from the sample to avoid a collision between the objective and the sample. ii. It can sometimes be very difficult to focus on flat and clean surfaces. The field stop diaphragm can help to overcome these difficulties as outlined in the following: To focus, close the field stop diaphragm. Approach the sample until the edge of the field stop appears focused. At this point, the sample is also in focus. This is because the field stop is positioned at the back focal plane of the objective. 11. Move the R/BF slider to the Raman position. 12. Turn off the white light illumination 13. Select an appropriate grating through the Spectrograph menu. Start with a low dispersion grating (300l/mm) that covers a large frequency range and move it to an appropriate wavenumber position (e.g. using a 532nm laser and the 300 l/mm grating, using 2050 rel. 1/cm as the spectral center is a good start). 14. Before opening the laser shutter, set the laser power to a value appropriate for the sample. If using the Silicon test sample, it should always be checked with maximum laser power. Open the laser shutter. 15. Start the oscilloscope in WITec Control using the Start Oscilloscope button in the oscilloscope menu of the Control Window. The integration time can be adjusted in the oscilloscope menu of the Control Window and should initially be set to s. You should now see a Raman spectrum of Silicon with the characteristic 1st order Si line at _520 cm-1, updated every 0.05s to 1s depending on the selected exposure time. Page 6 of 7
7 16. Adjust the focus of the microscope using the microscope Z stage (as described in point 9) to maximize the signal. 17. Once the optimum signal intensity is achieved, stop the oscilloscope with any Stop button or icon. 18. The parameters for an image scan, line scan, a single spectrum or a time series should then be defined. If an image scan is performed, the measurement parameters in the image scan menu of the Control Window should be adjusted (see WITec Control manual Section for a description of the individual parameters). If the (X), (Y) and (Z,Microscope) positions indicated in the scan table menu of the Control Window differ from the position entered as Center (X), Center (Y) and Center (Z) in the image scan menu, the scan table will move to a different position before starting the scan. This might then lead to data acquisition at the wrong position/area. Use the Center at Current Pos. button in the image scan menu of the ControlWindow to avoid this displacement. HINT Typical values for a confocal Raman imaging measurement are: a. Points per line: b. Lines per image: c. Width: 10-50μm d. Height: 10-50μm e. Integration Time: ms 19. You may now begin your measurement by opening the laser shutter and clicking on the corresponding Start button. 20. If an Image Scan is performed, you will see a FILTERMANAGER and two GRAPH windows: One of these will display the spectrum of your sample updated depending on the selected integration time. 21. A variety of images can be calculated from the spectra and displayed during the scan, without affecting the spectra acquisition. This is done by creating a new filter in the FILTER MANAGER window and selecting the appropriate spectral range in a displayed spectrum. Please refer to the WITec Project user manual (the functionality in WITec Control is identical) for more information about the variety of data evaluation tools available in this powerful software. Through the definition of filters in the FILTER MANGER, image data objects will be created which can be displayed in image windows. These image windows will display the calculated value of the Raman signal of your sample at each pixel. Clicking on any position in this image will display the spectrum obtained at this specific position in the second GRAPH window. This action does not affect the data acquisition. Finishing your session: When you have completed your measurements please be sure to complete the following steps to shut the system down: Close all laser shutters and turn off all lasers by turning the key counterclockwise. Move the microscope head up and place the 5X objective in the beam path. Turn off the visible light in the WITec video control. Close Control5 by going to file>exit. This is important as it will stop the camera cooling and if not completed the cameras will stay at -60 C. CLEAN UP! The lab should be left as clean as you found it. Disable Coral. Page 7 of 7
Confocal Raman Microscopy (WITec Alpha 300R)
Confocal Raman Microscopy (WITec Alpha 300R) Please refer to Witec Alpha300R Confocal Raman Microscope User Manual for the details of the operating procedure. Sample preparation 1. Attach your sample on
More informationRenishaw InVia Quick Operation Summary October 2018
Renishaw InVia Quick Operation Summary October 2018 This document is frequently updated if you feel information should be added, please indicate that to the facility manager (currently Philip Carubia,
More informationHoriba Jobin-Yvon LabRam Raman Confocal Microscope (GERB 120)
Horiba Jobin-Yvon LabRam Raman Confocal Microscope (GERB 120) Please contact Dr. Amanda Henkes for training requests and assistance: 979-862-5959, amandahenkes@tamu.edu Hardware LN 2 FTIR FTIR camera 1
More informationRENISHAW INVIA RAMAN SPECTROMETER
STANDARD OPERATING PROCEDURE: RENISHAW INVIA RAMAN SPECTROMETER Purpose of this Instrument: The Renishaw invia Raman Spectrometer is an instrument used to analyze the Raman scattered light from samples
More informationHoriba LabRAM ARAMIS Raman Spectrometer Revision /28/2016 Page 1 of 11. Horiba Jobin-Yvon LabRAM Aramis - Raman Spectrometer
Page 1 of 11 Horiba Jobin-Yvon LabRAM Aramis - Raman Spectrometer The Aramis Raman system is a software selectable multi-wavelength Raman system with mapping capabilities with a 400mm monochromator and
More informationKEYENCE VKX LASER-SCANNING CONFOCAL MICROSCOPE Standard Operating Procedures (updated Oct 2017)
KEYENCE VKX LASER-SCANNING CONFOCAL MICROSCOPE Standard Operating Procedures (updated Oct 2017) 1 Introduction You must be trained to operate the Laser-scanning confocal microscope (LSCM) independently.
More informationRenishaw InVia Raman microscope
Laser Spectroscopy Labs Renishaw InVia Raman microscope Operation instructions 1. Turn On the power switch, system power switch is located towards the back of the system on the right hand side. Wait ~10
More informationZeiss LSM 880 Protocol
Zeiss LSM 880 Protocol 1) System Startup Please note put sign-up policy. You must inform the facility at least 24 hours beforehand if you can t come; otherwise, you will receive a charge for unused time.
More informationOPT3: Operating Procedure for Horiba Jobin Yvon LabRam Aramis Raman/PL System See LabSpec_6_2 General User Quick Start Guide on the computer desktop
OPT3: Operating Procedure for Horiba Jobin Yvon LabRam Aramis Raman/PL System See LabSpec_6_2 General User Quick Start Guide on the computer desktop 1. Log in usage using the SMIF web site 2. Turn power
More informationZeiss LSM 780 Protocol
Zeiss LSM 780 Protocol 1) System Startup F Please note the sign-up policy. You must inform the facility at least 24 hours beforehand if you can t come; otherwise, you will receive a charge for unused time.
More informationSpectraPro 2150 Monochromators and Spectrographs
SpectraPro 215 Monochromators and Spectrographs SpectraPro 215 15 mm imaging spectrographs and monochromators from are the industry standard for researchers who demand the highest quality data. Acton monochromators
More informationRENISHAW RAMAN MICROSCOPE STANDARD OPERATING PROCEDURE
RENISHAW RAMAN MICROSCOPE STANDARD OPERATING PROCEDURE 09DJ00 CHRIS BUXEY (TECHNICIAN) X2715 C.BUXEY@SURREY.AC.UK V5.0 OCTOBER 2008 RENISHAW MICRORAMAN STANDARD OPERATING PROCEDURE 1.0 Foreword Chris Buxey:
More informationQuick Guide for Zeiss 710 Laser Scanning Confocal MGH Cancer Center
Quick Guide for Zeiss 710 Laser Scanning Confocal MGH Cancer Center For any questions or concerns, please contact: Linda Nieman lnieman@mgh.harvard.edu Office: (617) 643-9684 Cell: (512) 565-8076 Chenyue
More informationOriel MS260i TM 1/4 m Imaging Spectrograph
Oriel MS260i TM 1/4 m Imaging Spectrograph MS260i Spectrograph with 3 Track Fiber on input and InstaSpec CCD on output. The MS260i 1 4 m Imaging Spectrographs are economical, fully automated, multi-grating
More informationOverview. About other software. Administrator password. 58. UltraVIEW VoX Getting Started Guide
Operation 58. UltraVIEW VoX Getting Started Guide Overview This chapter outlines the basic methods used to operate the UltraVIEW VoX system. About other software Volocity places great demands on the computer
More informationTriVista. Universal Raman Solution
TriVista Universal Raman Solution Why choose the Princeton Instruments/Acton TriVista? Overview Raman Spectroscopy systems can be derived from several dispersive components depending on the level of performance
More informationCharacterization Microscope Nikon LV150
Characterization Microscope Nikon LV150 Figure 1: Microscope Nikon LV150 Introduction This upright optical microscope is designed for investigating up to 150 mm (6 inch) semiconductor wafers but can also
More informationMS260i 1/4 M IMAGING SPECTROGRAPHS
MS260i 1/4 M IMAGING SPECTROGRAPHS ENTRANCE EXIT MS260i Spectrograph with 3 Track Fiber on input and InstaSpec IV CCD on output. Fig. 1 OPTICAL CONFIGURATION High resolution Up to three gratings, with
More informationDIC Imaging using Laser Scanning Microscopes (LSMs) on Axio Imager Stands
DIC Imaging using Laser Scanning Microscopes (LSMs) on Axio Imager Stands Differential Interference Contrast (DIC) imaging is a technique used to increase contrast in brightfield images. In confocal systems,
More informationQuick Guide for Zeiss 710 Laser Scanning Confocal MGH Cancer Center
Quick Guide for Zeiss 710 Laser Scanning Confocal MGH Cancer Center For any questions or concerns, please contact: Linda Nieman lnieman@mgh.harvard.edu Office: (617) 643-9684 Cell: (512) 565-8076 Chenyue
More informationNikon AZ100. Laser Scanning Macro Confocal Microscope. Jordan Briscoe Adam Fries Kyle Marchuk Kaitlin Corbin. May 2017.
Nikon AZ100 Laser Scanning Macro Confocal Microscope Jordan Briscoe Adam Fries Kyle Marchuk Kaitlin Corbin May 2017 Contents 1 Introduction 2 2 Hardware - Startup 2 3 Software/Operation 4 3.1 Multidimensional
More informationZeiss AxioImager.Z2 Brightfield Protocol
Zeiss AxioImager.Z2 Brightfield Protocol 1) System Startup Please note put sign-up policy. You must inform the facility at least 24 hours beforehand if you can t come; otherwise, you will receive a charge
More informationOperation Guide for the Leica SP2 Confocal Microscope Bio-Imaging Facility Hunter College October 2009
Operation Guide for the Leica SP2 Confocal Microscope Bio-Imaging Facility Hunter College October 2009 Introduction of Fluoresence Confocal Microscopy The first confocal microscope was invented by Princeton
More informationGuide to Confocal 5. Starting session
Guide to Confocal 5 Remember that when booking and before starting session you can check for any problems at https://www.bris.ac.uk/biochemistry/uobonly/cif/index.html Starting session Switch on microscope
More informationLeica SPEII confocal microscope. Short Manual
Leica SPEII confocal microscope Short Manual Switching ON sequence: 1. Turn on the Workstation under the bench (top, far right). 2. Turn on the Supply Unit - Laser box (big green switch first and then
More informationFRAUNHOFER AND FRESNEL DIFFRACTION IN ONE DIMENSION
FRAUNHOFER AND FRESNEL DIFFRACTION IN ONE DIMENSION Revised November 15, 2017 INTRODUCTION The simplest and most commonly described examples of diffraction and interference from two-dimensional apertures
More informationLEICA TCS SP5 AOBS TANDEM USER MANUAL
LEICA TCS SP5 AOBS TANDEM USER MANUAL STARTING THE SYSTEM...2 THE LAS AF SOFTWARE...3 THE «ACQUIRE» MENU...5 CHOOSE AND CREATE A SETTING...6 THE CONTROL PANEL...8 THE DMI6000B MICROSCOPE...10 ACQUIRE ONE
More informationMotorized Axio Observer Start-up instructions
Start-up instructions 1. If using fluorescence turn on Fluorescent light source. TL light Source (Hal 100) 2. Turn on microscope using switch on lower left side of the microscope. 3. If imaging, turn on
More informationThings to check before start-up.
Byeong Cha Page 1 11/24/2009 Manual for Leica SP2 Confocal Microscope Enter you name, the date, the time, and the account number in the user log book. Things to check before start-up. Make sure that your
More informationLeica TCS SP8 Quick Start Guide
Leica TCS SP8 Quick Start Guide Leica TCS SP8 System Overview Start-Up Procedure 1. Turn on the CTR Control Box, EL6000 fluorescent light source for the microscope stand. 2. Turn on the Scanner Power
More informationCAPTURING IMAGES ON THE HIGH-MAGNIFICATION MICROSCOPE
University of Virginia ITC Academic Computing Health Sciences CAPTURING IMAGES ON THE HIGH-MAGNIFICATION MICROSCOPE Introduction The Olympus BH-2 microscope in ACHS s microscope lab has objectives from
More informationBX-61: Brightfield Instruction /Continue to scroll for Fluorescent Instuctions
BX-61: Brightfield Instruction /Continue to scroll for Fluorescent Instuctions Starting up: Schematic of Olympus BX-61. 1. Turn on Olympus microscope power box (left of microscope) with toggle switch on
More informationDIC Imaging using Laser Scanning Microscopes (LSM) on Inverted Stands
DIC Imaging using Laser Scanning Microscopes (LSM) on Inverted Stands Differential Interference Contrast (DIC) imaging is a technique used to increase contrast in brightfield images. In confocal systems,
More informationOperating Checklist for using the Laser Scanning Confocal Microscope. Leica TCS SP5.
Smith College August 2010 Operating Checklist for using the Laser Scanning Confocal Microscope Leica TCS SP5. CONTENT, page no. Startup, 1 Initial set-up, 1 Software, 2 Microscope Specimen observation
More informationImproving the Collection Efficiency of Raman Scattering
PERFORMANCE Unparalleled signal-to-noise ratio with diffraction-limited spectral and imaging resolution Deep-cooled CCD with excelon sensor technology Aberration-free optical design for uniform high resolution
More informationStandard Operating Procedure of Atomic Force Microscope (Anasys afm+)
Standard Operating Procedure of Atomic Force Microscope (Anasys afm+) The Anasys Instruments afm+ system incorporates an Atomic Force Microscope which can scan the sample in the contact mode and generate
More informationImproved Spectra with a Schmidt-Czerny-Turner Spectrograph
Improved Spectra with a Schmidt-Czerny-Turner Spectrograph Abstract For years spectra have been measured using traditional Czerny-Turner (CT) design dispersive spectrographs. Optical aberrations inherent
More informationFull-screen mode Popup controls. Overview of the microscope user interface, TEM User Interface and TIA on the left and EDS on the right
Quick Guide to Operating FEI Titan Themis G2 200 (S)TEM: TEM mode Susheng Tan Nanoscale Fabrication and Characterization Facility, University of Pittsburgh Office: M104/B01 Benedum Hall, 412-383-5978,
More informationFastest high definition Raman imaging. Fastest Laser Raman Microscope RAMAN
Fastest high definition Raman imaging Fastest Laser Raman Microscope RAMAN - 11 www.nanophoton.jp Observation A New Generation in Raman Observation RAMAN-11 developed by Nanophoton was newly created by
More informationLSM 510 Training Notes
LSM 510 Training Notes Turning on the system Turn on the arc lamp, found on the bench top left of the microscope. This supplies light for epifluorescence for viewing your samples through the microscope.
More informationNikon E800 Operating Instructions.
Nikon E800 Operating Instructions. You can request electronic copies of this manual by contacting lshats@jhsph.edu Copies are also available on the JHU MMI Department web site. Please send your comments
More informationIBIL setup operation manual for SynerJY software version
IBIL setup operation manual for SynerJY software version 1.8.5.0 Manual version 1.0, 31/10/2008 Author: Carlos Marques Equipment Managers: Carlos Marques, +351219946084, cmarques@itn.pt Luís Alves, +351219946112,
More informationInstruction Manual for HyperScan Spectrometer
August 2006 Version 1.1 Table of Contents Section Page 1 Hardware... 1 2 Mounting Procedure... 2 3 CCD Alignment... 6 4 Software... 7 5 Wiring Diagram... 19 1 HARDWARE While it is not necessary to have
More informationTRAINING MANUAL. Olympus FV1000
TRAINING MANUAL Olympus FV1000 September 2014 TABLE OF CONTENTS A. Start-Up Procedure... 1 B. Visual Observation under the Microscope... 1 C. Image Acquisition... 4 A brief Overview of the Settings...
More informationLSM 710 Confocal Microscope Standard Operation Protocol
LSM 710 Confocal Microscope Standard Operation Protocol Basic Operation Turning on the system 1. Switch on Main power switch 2. Switch on System / PC power button 3. Switch on Components power button 4.
More informationVS7550 VUV/UV Mini Spectrograph Operating Manual
Document RD 15 11 No: VS7550 VUV/UV Mini Spectrograph Operating Manual VS7550 Operating Manual 1 Table of Contents Table of Contents Overview Specifications Vacuum Interface Software and Drivers Packing
More informationUser Operation of JEOL 1200 EX II
**Log onto Computer** Open item program Start Up Procedure User Operation of JEOL 1200 EX II 1. If scope is not running, locate an electron microscopy technician (EMT) to find out why not. 2. Turn up brightness
More informationLSM 510 Meta Training Notes
LSM 510 Meta Training Notes Turning on the system Turn on X-Cite power supply. This supplies light for epifluorescence for viewing your samples through the microscope. Turn on the remote control switch.
More informationSHORT INSTRUCTIONS FOR OPERATING LSM1/2 (Zeiss LSM510) AT CIAN Version 1.4, September 2014
CIAN LSM1 or LSM2 short instructions, version 1.4, September 2014 page 1 of 6 SHORT INSTRUCTIONS FOR OPERATING LSM1/2 (Zeiss LSM510) AT CIAN Version 1.4, September 2014 Before starting To work with LSM1
More informationFast Laser Raman Microscope RAMAN
Fast Laser Raman Microscope RAMAN - 11 www.nanophoton.jp Fast Raman Imaging A New Generation of Raman Microscope RAMAN-11 developed by Nanophoton was created by combining confocal laser microscope technology
More informationLeica TCS SP8 Quick Start Guide
Leica TCS SP8 Quick Start Guide Leica TCS SP8 System Overview Start-Up Procedure 1. Turn on the CTR Control Box, Fluorescent Light for the microscope stand. 2. Turn on the Scanner Power (1) on the front
More informationFast Laser Raman Microscope RAMAN
Fast Laser Raman Microscope RAMAN - 11 www.nanophoton.jp Fast Raman Imaging A New Generation of Raman Microscope RAMAN-11 developed by Nanophoton was created by combining confocal laser microscope technology
More informationSPINNING DISK CSU-X1 USER MANUAL
SPINNING DISK CSU-X1 USER MANUAL Starting the temperature controller... 2 Starting the CO2 controller... 3 Start the spinning disk... 4 Sample observation with the oculars... 5 Spatial sampling, Pixel
More informationb. Turn the power switch and key to on position for blue laser.
OLYMPUS FLUOVIEW 300 CONFOCAL MICOSCOPE OPERATION PROCEDURE 1. Turn ON microscope in this order: 1) Turn on mercury lamp (Note: once the mercury lamp is turned off, DO NOT turn it back on for at least
More informationMicroscopic Structures
Microscopic Structures Image Analysis Metal, 3D Image (Red-Green) The microscopic methods range from dark field / bright field microscopy through polarisation- and inverse microscopy to techniques like
More informationNikon C1si Spectral Laser Scanning Confocal Microscope. User Guide
Nikon C1si Spectral Laser Scanning Confocal Microscope User Guide Contents: C1Si Turn-On/ShutDown Procedures... 2 Overview... 4 Setup for epi-illumination to view through the eyepieces:... 5 Setup for
More informationPractical work no. 3: Confocal Live Cell Microscopy
Practical work no. 3: Confocal Live Cell Microscopy Course Instructor: Mikko Liljeström (MIU) 1 Background Confocal microscopy: The main idea behind confocality is that it suppresses the signal outside
More informationZeiss 780 Training Notes
Zeiss 780 Training Notes Turn on Main Switch, System PC and Components Switches 780 Start up sequence Do you need the argon laser (458, 488, 514 nm lines)? Yes Turn on the laser s main power switch and
More informationADVANCED OPTICS LAB -ECEN Basic Skills Lab
ADVANCED OPTICS LAB -ECEN 5606 Basic Skills Lab Dr. Steve Cundiff and Edward McKenna, 1/15/04 Revised KW 1/15/06, 1/8/10 Revised CC and RZ 01/17/14 The goal of this lab is to provide you with practice
More informationMicroscopy. The dichroic mirror is an important component of the fluorescent scope: it reflects blue light while transmitting green light.
Microscopy I. Before coming to lab Read this handout and the background. II. Learning Objectives In this lab, you'll investigate the physics of microscopes. The main idea is to understand the limitations
More informationInstructions for the Experiment
Instructions for the Experiment Excitonic States in Atomically Thin Semiconductors 1. Introduction Alongside with electrical measurements, optical measurements are an indispensable tool for the study of
More informationLeica SP8 TCS Users Manual
Leica SP8 TCS Users Manual Follow the procedure for start up and log on as posted in the lab. Please log on with your account only and do not share your password with anyone. We track and confirm usage
More informationBi/BE 227 Winter Assignment #3. Adding the third dimension: 3D Confocal Imaging
Bi/BE 227 Winter 2016 Assignment #3 Adding the third dimension: 3D Confocal Imaging Schedule: Jan 20: Assignment Jan 20-Feb 8: Work on assignment Feb 10: Student PowerPoint presentations. Goals for this
More informationLSM 780 Confocal Microscope Standard Operation Protocol
LSM 780 Confocal Microscope Standard Operation Protocol Basic Operation Turning on the system 1. Sign on log sheet according to Actual start time 2. Check Compressed Air supply for the air table 3. Switch
More information1/8 m GRATING MONOCHROMATOR
1/8 m GRATING GRATING OUTPUT PORT INPUT PORT 77250 1/8 m Monochromator with 6025 Hg(Ar) Spectral Calibration Lamp. Low cost, compact size and high performance, ideal for OEM applications Very efficient
More informationNikon Eclipse Ti A1-A Confocal Operating Manual. Start-up. Microscope
Nikon Eclipse Ti A1-A Confocal Operating Manual Start-up 1. Turn on Excite Fluorescent light power supply- metal halide. a. Cool down as for mercury bulb b. Wheel closed liquid light guide 2. Turn on power
More informationADVANCED OPTICS LAB -ECEN 5606
ADVANCED OPTICS LAB -ECEN 5606 Basic Skills Lab Dr. Steve Cundiff and Edward McKenna, 1/15/04 rev KW 1/15/06, 1/8/10 The goal of this lab is to provide you with practice of some of the basic skills needed
More informationPANalytical X pert Pro Gazing Incidence X-ray Reflectivity User Manual (Version: )
University of Minnesota College of Science and Engineering Characterization Facility PANalytical X pert Pro Gazing Incidence X-ray Reflectivity User Manual (Version: 2012.10.17) The following instructions
More information3. are adherent cells (ie. cells in suspension are too far away from the coverslip)
Before you begin, make sure your sample... 1. is seeded on #1.5 coverglass (thickness = 0.17) 2. is an aqueous solution (ie. fixed samples mounted on a slide will not work - not enough difference in refractive
More informationOlympus Fluoview 1000S Spectral Confocal Microscope Introduction to the NRI-MCDB Microscopy Facility Spectral Confocal Microscope
Olympus Fluoview 1000S Spectral Confocal Microscope Introduction to the NRI-MCDB Microscopy Facility Spectral Confocal Microscope Improved Optics More Lasers 405 diode 440 diode 488 Argon 515 Argon 559
More informationUNIVERSITY OF WATERLOO Physics 360/460 Experiment #2 ATOMIC FORCE MICROSCOPY
UNIVERSITY OF WATERLOO Physics 360/460 Experiment #2 ATOMIC FORCE MICROSCOPY References: http://virlab.virginia.edu/vl/home.htm (University of Virginia virtual lab. Click on the AFM link) An atomic force
More informationOperating Instructions for Zeiss LSM 510
Operating Instructions for Zeiss LSM 510 Location: GNL 6.312q (BSL3) Questions? Contact: Maxim Ivannikov, maivanni@utmb.edu 1 Attend A Complementary Training Before Using The Microscope All future users
More informationLeica SP8 TCS Users Manual
Version : 07/08/0 Leica SP8 TCS Users Manual Start up:. Turn the PC Microscope, Scanner Power, Laser Power, and the Laser Emission key to on (bottom right of desk).. Turn on the fluorescent lamp (top left
More informationOcean Optics R-2000 Raman Spectrometer Setup and Operating Instructions Arlen Viste and Deanna Donohoue April 2000 Update 2003, DEW
Ocean Optics R-2000 Raman Spectrometer Setup and Operating Instructions Arlen Viste and Deanna Donohoue April 2000 Update 2003, DEW References Raman Systems R-2000 Operating Manual, Version 1.6, Ocean
More informationNikon E800 Operating Instructions.
Nikon E800 Operating Instructions. You can request electronic copies of this manual by contacting imaging@fhcrc.org. Copies are also available on the Scientific Imaging web site. Please send your comments
More informationBasic Users Manual for Tecnai-F20 TEM
Basic Users Manual for Tecnai-F20 TEM NB: This document contains my personal notes on the operating procedure of the Tecnai F20 and may be used as a rough guide for those new to the microscope. It may
More informationPerformance Comparison of Spectrometers Featuring On-Axis and Off-Axis Grating Rotation
Performance Comparison of Spectrometers Featuring On-Axis and Off-Axis Rotation By: Michael Case and Roy Grayzel, Acton Research Corporation Introduction The majority of modern spectrographs and scanning
More informationDiskovery Spinning Disk Guide
Diskovery Spinning Disk Guide qbi.microscopy@uq.edu.au Getting started The microscope and its peripherals (Fig. 1a) should always be turned on, but if they are not, turn them on in the following way: 1.
More informationGuide to SPEX Optical Spectrometer
Guide to SPEX Optical Spectrometer GENERAL DESCRIPTION A spectrometer is a device for analyzing an input light beam into its constituent wavelengths. The SPEX model 1704 spectrometer covers a range from
More informationJEOL 6500 User Manual
LOG IN to your session on the computer to the left of the microscope. Starting Conditions 1. Press Ctrl-Alt-Del and log on to the microscope computer. Click on JEOL PC SEM 6500 icon. Click yes if message
More informationQuick Start MMRC Nicolet 6700 Revised 10/24/2018
Do Not Remove Quick Start MMRC Nicolet 6700 Revised 10/24/2018 1. Fill out the logbook before you begin. 2. Before you start the Nicolet should be on with purge gas flowing. 3. Check that the purge gas
More informationWidefield-NikonEclipseTE200-ORCA Nikon Eclipse TE200 Inverted Microscope with Hamamatsu 1394 Orca-ER Cooled CCD Camera and Micromanager Software
Widefield-NikonEclipseTE200-ORCA Nikon Eclipse TE200 Inverted Microscope with Hamamatsu 1394 Orca-ER Cooled CCD Camera and Micromanager Software September 2007 Check website for most current User Guide
More informationOriel Cornerstone 130 1/8 m Monochromator
1 Oriel Cornerstone 130 1/8 m Monochromator Cornerstone 130 1/8 m Monochromator The Cornerstone 130 family of Oriel Monochromators supports two gratings simultaneously, which can be easily interchanged,
More informationUV-Vis-NIR Spectrophotometer Quick Start Guide
UV-Vis-NIR Spectrophotometer Quick Start Guide The following instructions are provided as a Quick Start Guide for powering up, running measurements, and shutting down the Lambda 950 UV-Vis Spectrophotometer.
More informationNikon Eclipse Ti2-E Widefield/Spinning Disk Confocal Microscope Standard Operation Protocol
Nikon Eclipse Ti-E Widefield/Spinning Disk Confocal Microscope Standard Operation Protocol Please sign on the log sheet before switching on system. Turn on system Turn on A only if confocal mode or laser
More informationLeica DMi8A Quick Guide
Leica DMi8A Quick Guide 1 Optical Microscope Quick Start Guide The following instructions are provided as a Quick Start Guide for powering up, running measurements, and shutting down Leica s DMi8A Inverted
More informationUse of the HSW5 Spinning Disk Confocal Microscope Updated last May 25, 2010 OK
Use of the HSW5 Spinning Disk Confocal Microscope Updated last May 25, 2010 OK Getting Started: 2 Starting Micromanager and Loading a Configuration 3 The Main Micromanager GUI 3 Configuration Settings
More informationSpotlight 150 and 200 FT-IR Microscopy Systems
S P E C I F I C A T I O N S Spotlight 150 and 200 FT-IR Microscopy Systems FT-IR Microscopy Spotlight 200 with Frontier FT-IR Spectrometer Introduction PerkinElmer Spotlight FT-IR Microscopy Systems are
More informationSTEM Spectrum Imaging Tutorial
STEM Spectrum Imaging Tutorial Gatan, Inc. 5933 Coronado Lane, Pleasanton, CA 94588 Tel: (925) 463-0200 Fax: (925) 463-0204 April 2001 Contents 1 Introduction 1.1 What is Spectrum Imaging? 2 Hardware 3
More informationSabeeh Irfan Ahmad, Physlab, 23 July 2016
Horiba ihr550 Spectrometer QuickInstallation and Operation Guide Sabeeh Irfan Ahmad, Physlab, 23 July 2016 The Horiba ihr550 is an imaging spectrometer that can be used both as a spectrograph and as a
More informationKit for building your own THz Time-Domain Spectrometer
Kit for building your own THz Time-Domain Spectrometer 16/06/2016 1 Table of contents 0. Parts for the THz Kit... 3 1. Delay line... 4 2. Pulse generator and lock-in detector... 5 3. THz antennas... 6
More informationZeiss 880 Training Notes Zen 2.3
Zeiss 880 Training Notes Zen 2.3 1 Turn on the HXP 120V Lamp 2 Turn on Main Power Switch Turn on the Systems PC Switch Turn on the Components Switch. 3 4 5 Turn on the PC and log into your account. Start
More informationFigure 1. Oil-immersion objectives available for use with the Lionheart FX.
Tech Note Oil Objective Introduction The Lionheart FX automated imager is compatible with high numerical aperture oil immersion objectives. These objectives offer magnification up to 100X and significantly
More informationMicroscopy from Carl Zeiss
Microscopy from Carl Zeiss Contents Page Contents... 1 Introduction... 1 Starting the System... 2 Introduction to ZEN Efficient Navigation... 5 Setting up the microscope... 10 Configuring the beam path
More informationTitle: Leica SP5 Confocal User Manual
Title: Leica SP5 Confocal User Manual Date of first issue: 23/10/2015 Date of review: Version: Admin For assistance or to report an issue Office: CG07 or 05 Email: Igmm-imaginghelpdesk@igmm.ed.ac.uk Website:
More informationNikon Ti-E Microscope Manual. Rightmire Hall Ohio State University. Director: Tony Brown Rightmire
Nikon Ti-E Microscope Manual Rightmire Hall Ohio State University Director: Tony Brown Rightmire 060 292-1205 brown.2302@osu.edu Facility Manager: Paula Monsma Rightmire 062 293-0939 292-1367 monsma.1@osu.edu
More informationECEN. Spectroscopy. Lab 8. copy. constituents HOMEWORK PR. Figure. 1. Layout of. of the
ECEN 4606 Lab 8 Spectroscopy SUMMARY: ROBLEM 1: Pedrotti 3 12-10. In this lab, you will design, build and test an optical spectrum analyzer and use it for both absorption and emission spectroscopy. The
More informationOPERATION OF THE HITACHI S-450 SCANNING ELECTRON MICROSCOPE. by Doug Bray Department of Biological Sciences University of Lethbridge
OPERATION OF THE HITACHI S-450 SCANNING ELECTRON MICROSCOPE by Doug Bray Department of Biological Sciences University of Lethbridge Revised September, 2000 Note: The terms in bold in this document represent
More information880 Quantum Electronics Optional Lab Construct A Pulsed Dye Laser
880 Quantum Electronics Optional Lab Construct A Pulsed Dye Laser The goal of this lab is to give you experience aligning a laser and getting it to lase more-or-less from scratch. There is no write-up
More informationRaman Spectroscopy of TiO2
Raman Spectroscopy of TiO2 Experiment #4 Characterization of Materials (96.445/545) Meg Noah Meg Noah 1 of 8 10/21/2010 Objective The purpose of this laboratory is to identify two different phases (rutile
More information