Instructions for the Experiment

Size: px
Start display at page:

Download "Instructions for the Experiment"

Transcription

1 Instructions for the Experiment Excitonic States in Atomically Thin Semiconductors 1. Introduction Alongside with electrical measurements, optical measurements are an indispensable tool for the study of semiconductor materials, as they reveal many of the materials properties. In this experiment, photoluminescence and reflectance measurements are employed in order to study excitonic physics in WSe2 monolayers. This document describes the experimental setup in detail and explains how the experiments are to be performed. It will also give instructions on how to analyze the acquired data. 2. Experimental Setup A picture of the experimental setup is shown in illustration 1. The whole setup is built on top of an optical table. In the following sections, the different components of this setup are explained, following the path of the light in the setup. Illustration 1: Top view of the optical setup. The green, red and white lines represent the excitation path, the detection path and the path of the white light, respectively.

2 2.1 Laser Sources Several laser sources are available for the optical excitation of the sample. The lasers differ in photon energy (wavelength) and laser type (pulsed or continuous wave). Since in this experiment only time-integrated measurements are performed, a 660nm continuous wave diode laser (illustration 2a) is used, which excites the WSe2 monolayer at a photon energy higher than the material s optical band gap but lower than the B-exciton energy or its electronic band gap. 2.2 Excitation Path The laser light is guided to the cryostat using a set of mirrors, a beam splitter and a scanning mirror system. The properties of the exciting laser light can be modified via a combination of optical components in the excitation path: The intensity of the incident laser light can be adjusted using neutral density filters. A motorized filter wheel (illustration 2b) provides discrete transmission factors between and 1. In this experiment transmission factors down to are useful. The laser light can be spectrally cleaned using a suitable band pass filter. This avoids that low energy laser modes (or spontaneous recombination) are superimposed on the photoluminescence signal from the sample. Another filter wheel (illustration 2c) provides a set of band pass filters. For the 660nm diode laser, a band pass filter with a central wavelength of 660nm is available. In order to define the polarization of the laser light, a linear polarizer, a half-wave-plate and a quarter-wave-plate (illustration 2d) can be introduced into the excitation path. These three optical components are sufficient to change the polarization of an arbitrarily polarized input beam into any desired polarization. Illustration 2: a) laser source, b) neutral density filter wheel, c) band pass filter wheel, d) polarization optics Illustration 3: a) beam splitter, b) optical diode, c) scanning mirror, d) 4f-relay-lens-system After setting the beam properties, a beam splitter (illustration 3a) splits the exciting beam into two parts; one is used to excite the sample and the other one is used to measure the laser intensity using an optical diode (illustration 3b). A tiltable scanning mirror (illustration 3c) is used in combination with a 4f-relay-lens-system (illustration 3d) in order to scan the beam across the sample surface.

3 The 4f setup relocates the center of rotation the objective within the cryostat (illustration 4). from the scanning mirror into Illustration 4: Working principle of a 4f-relay-lens-setup. The scanning mirror can be tilted in order to deflect the beam. Two lenses with identical focal lengths relocate the center of rotation from the center of the scanning mirror into the center of the objective. 2.3 Cryostat A picture of the open cold-finger cryostat is shown in illustration 5. The sample is placed on the cold finger of the cryostat with the sample surface facing downwards. The temperature of the sample can be lowered to 11K using liquid Helium. The objective with a focal length of approximately 3mm is located within the cryostat. The sample can be moved using an x-y-z stepper stage. Two thermometers are continuously measuring the temperatures of the cold-finger and the sample. The cryostat provides electrical contacts to the sample. However, for this experiment, no electrical contacts to the sample are needed. 2.4 Detection Path Illustration 5: Open cryostat. The light emitted from the WSe2 monolayer is collected by the objective and then guided to the spectrometer. In the detection path different optical components can be used to analyze the emitted light before spectrally resolving it with the spectrometer: Similar to the definition of the polarization in the excitation path, a quarter-wave-plate, a half-wave-plate and a linear polarizer (illustration 6a) are sufficient in order to determine fully the polarization state of the emitted light.

4 The laser light is spectrally filtered using a long-pass filter in front of the spectrometer (illustration 6b). In this experiment a long-pass filter with an edge position at 700nm is used, which reflects the laser light but transmits the photoluminescence signal. Note that for reflectance measurements, this filter needs to be removed. For reflectance measurements, a spatial filtering of the signal is required. For this purpose a confocal setup including two lenses and a pinhole can be inserted in the detection path (illustration 6c). Finally, the emitted light is focused on the entry slit of the spectrometer (illustration 6d) and dispersed on a CCD. Illustration 6: a) polarization optics, b) 700nm long-pass filter, c) confocal filtering, d) spectrometer entrance slit 2.5 Imaging In order to find the position of interest on the sample, the sample surface can be imaged. For this purpose the sample can be illuminated with white light and the reflected light can be imaged on a CCD camera. A pellicle beam splitter on a flip mount allows for easy on- and off-switching of the imaging path. 3. Software Most components of the experimental setup can be controlled remotely from a computer. In some cases (alignment of optical components, finding a point of interest on the sample), it is convenient to use the instrument software provided by the instrument manufacturers. However, in the real measurements, where many instruments need to be synchronized, a Python-based data acquisition framework called QCoDeS will be used. Almost all instruments in this setup can be integrated with QCoDeS. In the next sections, the software used throughout the whole experiment is explained. 3.1 Attocube Daisy The Attocube Daisy software is used to control the x-y-z stepper stage within the cryostat. The xand y-axes are used to laterally move over the sample, whereas the z-axis is used to move the sample into the focus of the objective. In the software each axis is represented by another tab. For the movement of the axes, a voltage and a frequency need to be set. At a sample temperature of 11K, the voltages should be set to 55V. The frequencies need to be set according to the desired axis speed.

5 3.2 Andor Camera The Andor Camera software (illustration 7) is used for the imaging of the sample. After starting the software, the parameters for the image acquisition need to be set: 1. Acquisition Setup Acquisition Setup Camera The exposure time should be set to a reasonable value. Too low exposure time leads to noisy images, whereas too high exposure time leads to a saturation of the CCD, which can result in damage. 2. Acquisition Setup Acquisition Image Orientation The image should be flipped both horizontally and vertically in order to achieve a unrotated image of the sample. 3. Hardware Shutter Control The internal shutter should be set to permanently open. After setting up all acquisition parameters, the sample can be imaged by clicking on the small video symbol (red circle in illustration 7). Illustration 7: Screenshot of the Andor Camera software. In order to reduce the amount of stray light, the Andor camera software provides the option to remove a background image from the acquired image. This mode can be enabled by 1. Acquisition Setup Data Type: Select Counts (BG corrected) 2. Acquisition Take Background: Take a background image at a plane spot of the sample. 3.3 Andor Spectrometer The Andor Spectrometer software (illustration 8) is used in order to measure the spectrum of the light that enters the spectrometer. After starting the software, the parameters for the spectrum acquisition need to be set: 1. Select a suitable grating (red box in illustration 8). The grating determines the spectral resolution, as well as the covered spectral range. For photoluminescence measurements, a

6 grating with 600 lines per mm is recommended. For reflectance measurements, a grating with 299 lines per mm is recommended. 2. Set the shutter to auto (blue box in illustration 8). 3. Close the slit (green box in illustration 8) in order to minimize the amount of stray light in the spectrum. For a well-aligned setup, a slit width of 100um is recommended. 4. Set the central wavelength of the grating (orange box in illustration 8). The central wavelength depends on the spectrum that one wants to measure. 5. Set a suitable exposure time (purple box in illustration 8). A suitable exposure time should minimize the signal-to-noise ratio while keeping but keep the experiments short. After setting the parameters, the spectrum acquisition can be started (yellow circle in illustration 8). Illustration 8: Screenshot of the Andor Spectrometer software. 3.4 QCoDeS QCoDeS is a Python-based data acquisition framework that allows for easy integration of multiple instruments involved in a measurement. As an example, a measurement of the excitation power dependency of a spectrum requires control over at least three instruments: 1. The neutral density filter wheel sets the intensity of the exciting laser light. 2. The optical diode at the transmission side of the beam splitter measures the laser intensity. 3. The spectrometer acquires the spectrum of the light emitted from the sample. QCoDeS can be controlled from Jupyter notebooks. In this experiment predefined Jupyter notebooks are provided to the students. These notebooks include the Python codes for the

7 measurements in this experiment, as well as detailed instructions on how to perform these measurements. 4. Measurement Instructions 4.1 Aligning the setup After the optical setup is taken over by a new person, one should check the proper alignment of the setup. This includes the following steps. 1. Make sure you are wearing laser safety goggles suitable for the laser used. 2. Make sure the laser beam is aligned with the cage system of the optical setup. Pinholes within the cage system can be closed and used as a reference for the cage center. Two mirrors are sufficient to fully align the beam with any of the cages. 3. Make sure the laser enters the objective centrally. For this purpose, one can move the sample slightly away from the focus point and observe the Airy pattern on the camera. If it does not look symmetric, the mirror underneath the cryostat can be used to correct the beam path. 4. The emitted light needs to be focused well onto the entry slit of the spectrometer. For this purpose, the focusing lens in front of the spectrometer is placed on an x-y-stage. This stage should be used to maximize the counts on the spectrometer with the slit being closed to a reasonable value Finding the WSe2 monolayer The WSe2 monolayer has a size on the order of 10um and is placed on a 5mm SiO2 chip. The chip is equipped with metal markers (illustration 9), which allow for the localization of the monolayer using the x- and y-axes of the stepper stage in the cryostat. On the day of the experiment, the students will receive micrographs of the freshly prepared sample together with all the necessary information on its location on the chip. 4.3 Photoluminescence Map A photoluminescence map of the WSe2 monolayer is Illustration 9: Chip layout. acquired. For this purpose, the monolayer is scanned using the tiltable scanning mirror. After each step of the scanning mirror, a spectrum is acquired with the spectrometer. This measurement can be run from the Jupyter notebook photoluminescence_map.ipynb. The hyperspectral dataset can be analyzed using the Py2DSpectroscopy software ( A detailed description and a video tutorial can be found on the github page. The highest quality position on the sample (lowest emission linewidth) can be found using Py2DSpectroscopy. All further experiments should be performed at this position.

8 4.4 Power Dependence Measurement A power dependence measurement of the WSe2 monolayer photoluminescence can be performed using the automatic neutral density filter wheel. The measurement can be run from the Jupyter notebook power_dependence.ipynb. The acquired dataset can be analyzed using the Py2DSpectroscopy software. From this measurement a suitable excitation power for further measurements can be obtained. A good excitation power gives narrow linewidth emission but keeps the measurement duration short. 4.5 Polarization Dependence Measurement For the polarization dependence measurement, the polarization optics need to be inserted in the excitation and detection paths of the optical table. On each side, a linear polarizer, a half-wave-plate and a quarter-wave-plate are needed (illustration 10). Illustration 10: Polarization optics in the excitation and detection paths. The polarization optics in the excitation path are used to set the polarization of the exciting laser light. The students will be provided a calibration sheet (i.e. the rotation offsets) of the polarization optics on the day of the experiment. The sample should be excited using R-, L-, H- and V-polarized laser light. For each excitation polarization R-, L-, H- and V-polarized light should be detected. In total, 16 spectra need to be acquired. This measurement can be run from the Jupyter notebook polarization_dependence.ipynb. 4.6 Reflectance Measurement In the reflectance measurement, the reflection of white light from the WSe 2 surface is measured. This reflection is then compared to the reflection from the SiO 2 surface in order to obtain the reflectance of the sample. In contrast to the photoluminescence emission, the reflected white light needs to be filtered spatially. For this purpose a confocal setup including two lenses and a pinhole is inserted in the detection path. The pinhole position is then aligned by maximizing the laser counts on the spectrometer. The laser source can now be turned off (or blocked) and the white light source is turned on. The semi-transparent pellicle needs to flipped such that it reflects the white light towards the sample. The reflection from about five points on the WSe2 monolayer should be measured. In order to obtain identical illumination conditions for the reflection measurements on WSe 2 and SiO2 the Attocube stage is now used to move the probe area away from the WSe 2 monolayer. Then, the light is measured at the same positions as on the WSe2 monolayer. This measurement can be run from the Jupyter notebook reflectance.ipynb.

9 5. Data Analysis The acquired data should be used to gain insight into excitonic physics in a WSe2 monolayer. 5.1 Identification of Excitonic Complexes The students are asked to identify as many excitonic complexes as possible and specify their optical properties. From the acquired photoluminescence map the students should make a list of all observed emission energies. Please note that the emission energy of a single excitonic line may vary by a few mev across the sample due to mechanical strain. From the power dependence measurements, the students should extract the integrated intensity of an excitonic line as a function of laser intensity. Plotting these intensities on a log-log plot will let the students fit a linear function to the plotted data. The slopes of these fits reveal information on the nature of each excitonic line. Biexcitonic complexes tend to have slopes larger than 1 whereas excitons and trions show slopes smaller than 1. From the polarization dependence measurements, the students should specify which of the excitonic lines show circular dichroism and valley coherence. This will give further insight into the nature of each excitonic line. 5.2 Determination of the Optical and Electronic Band Gap The students are asked to estimate the binding energy of the lowest energy excitonic state. The optical band gap can be determined by measuring the emission energy of the neutral exciton. Since this value varies across the sample (due to strain) a spatially averaged value with standard deviation should be reported. The exciton binding energy can be approximately obtained from the spacing between the two lowest states of the neutral exciton. For this purpose, the reflectance data has to be analyzed. The normalized reflectance can be calculated as Δ R= R monolayer R substrate R substrate The oscillator strength of the first excited state of the neutral exciton is weak compared to its ground state. Therefore, plotting the derivative of ΔR can make this state more visible. Smoothing the data for example with the Savitzky-Golay algorithm may further improve the visibility of this state. For two-dimensional semiconductors it is expected that Eb 2 Δ E 1,2. With this approximation, the students can make an estimate for the electronic band gap of the material.

ECEN. Spectroscopy. Lab 8. copy. constituents HOMEWORK PR. Figure. 1. Layout of. of the

ECEN. Spectroscopy. Lab 8. copy. constituents HOMEWORK PR. Figure. 1. Layout of. of the ECEN 4606 Lab 8 Spectroscopy SUMMARY: ROBLEM 1: Pedrotti 3 12-10. In this lab, you will design, build and test an optical spectrum analyzer and use it for both absorption and emission spectroscopy. The

More information

Horiba LabRAM ARAMIS Raman Spectrometer Revision /28/2016 Page 1 of 11. Horiba Jobin-Yvon LabRAM Aramis - Raman Spectrometer

Horiba LabRAM ARAMIS Raman Spectrometer Revision /28/2016 Page 1 of 11. Horiba Jobin-Yvon LabRAM Aramis - Raman Spectrometer Page 1 of 11 Horiba Jobin-Yvon LabRAM Aramis - Raman Spectrometer The Aramis Raman system is a software selectable multi-wavelength Raman system with mapping capabilities with a 400mm monochromator and

More information

MASSACHUSETTS INSTITUTE OF TECHNOLOGY Department of Electrical Engineering and Computer Science

MASSACHUSETTS INSTITUTE OF TECHNOLOGY Department of Electrical Engineering and Computer Science Student Name Date MASSACHUSETTS INSTITUTE OF TECHNOLOGY Department of Electrical Engineering and Computer Science 6.161 Modern Optics Project Laboratory Laboratory Exercise No. 6 Fall 2010 Solid-State

More information

Applications of Steady-state Multichannel Spectroscopy in the Visible and NIR Spectral Region

Applications of Steady-state Multichannel Spectroscopy in the Visible and NIR Spectral Region Feature Article JY Division I nformation Optical Spectroscopy Applications of Steady-state Multichannel Spectroscopy in the Visible and NIR Spectral Region Raymond Pini, Salvatore Atzeni Abstract Multichannel

More information

Horiba Jobin-Yvon LabRam Raman Confocal Microscope (GERB 120)

Horiba Jobin-Yvon LabRam Raman Confocal Microscope (GERB 120) Horiba Jobin-Yvon LabRam Raman Confocal Microscope (GERB 120) Please contact Dr. Amanda Henkes for training requests and assistance: 979-862-5959, amandahenkes@tamu.edu Hardware LN 2 FTIR FTIR camera 1

More information

Practical work no. 3: Confocal Live Cell Microscopy

Practical work no. 3: Confocal Live Cell Microscopy Practical work no. 3: Confocal Live Cell Microscopy Course Instructor: Mikko Liljeström (MIU) 1 Background Confocal microscopy: The main idea behind confocality is that it suppresses the signal outside

More information

Spectroscopy of Ruby Fluorescence Physics Advanced Physics Lab - Summer 2018 Don Heiman, Northeastern University, 1/12/2018

Spectroscopy of Ruby Fluorescence Physics Advanced Physics Lab - Summer 2018 Don Heiman, Northeastern University, 1/12/2018 1 Spectroscopy of Ruby Fluorescence Physics 3600 - Advanced Physics Lab - Summer 2018 Don Heiman, Northeastern University, 1/12/2018 I. INTRODUCTION The laser was invented in May 1960 by Theodor Maiman.

More information

Characteristics of point-focus Simultaneous Spatial and temporal Focusing (SSTF) as a two-photon excited fluorescence microscopy

Characteristics of point-focus Simultaneous Spatial and temporal Focusing (SSTF) as a two-photon excited fluorescence microscopy Characteristics of point-focus Simultaneous Spatial and temporal Focusing (SSTF) as a two-photon excited fluorescence microscopy Qiyuan Song (M2) and Aoi Nakamura (B4) Abstracts: We theoretically and experimentally

More information

Observational Astronomy

Observational Astronomy Observational Astronomy Instruments The telescope- instruments combination forms a tightly coupled system: Telescope = collecting photons and forming an image Instruments = registering and analyzing the

More information

A novel tunable diode laser using volume holographic gratings

A novel tunable diode laser using volume holographic gratings A novel tunable diode laser using volume holographic gratings Christophe Moser *, Lawrence Ho and Frank Havermeyer Ondax, Inc. 85 E. Duarte Road, Monrovia, CA 9116, USA ABSTRACT We have developed a self-aligned

More information

CONFIGURING. Your Spectroscopy System For PEAK PERFORMANCE. A guide to selecting the best Spectrometers, Sources, and Detectors for your application

CONFIGURING. Your Spectroscopy System For PEAK PERFORMANCE. A guide to selecting the best Spectrometers, Sources, and Detectors for your application CONFIGURING Your Spectroscopy System For PEAK PERFORMANCE A guide to selecting the best Spectrometers, s, and s for your application Spectral Measurement System Spectral Measurement System Spectrograph

More information

Kit for building your own THz Time-Domain Spectrometer

Kit for building your own THz Time-Domain Spectrometer Kit for building your own THz Time-Domain Spectrometer 16/06/2016 1 Table of contents 0. Parts for the THz Kit... 3 1. Delay line... 4 2. Pulse generator and lock-in detector... 5 3. THz antennas... 6

More information

RENISHAW INVIA RAMAN SPECTROMETER

RENISHAW INVIA RAMAN SPECTROMETER STANDARD OPERATING PROCEDURE: RENISHAW INVIA RAMAN SPECTROMETER Purpose of this Instrument: The Renishaw invia Raman Spectrometer is an instrument used to analyze the Raman scattered light from samples

More information

Guide to SPEX Optical Spectrometer

Guide to SPEX Optical Spectrometer Guide to SPEX Optical Spectrometer GENERAL DESCRIPTION A spectrometer is a device for analyzing an input light beam into its constituent wavelengths. The SPEX model 1704 spectrometer covers a range from

More information

Light Microscopy. Upon completion of this lecture, the student should be able to:

Light Microscopy. Upon completion of this lecture, the student should be able to: Light Light microscopy is based on the interaction of light and tissue components and can be used to study tissue features. Upon completion of this lecture, the student should be able to: 1- Explain the

More information

Improving the Collection Efficiency of Raman Scattering

Improving the Collection Efficiency of Raman Scattering PERFORMANCE Unparalleled signal-to-noise ratio with diffraction-limited spectral and imaging resolution Deep-cooled CCD with excelon sensor technology Aberration-free optical design for uniform high resolution

More information

Renishaw InVia Raman microscope

Renishaw InVia Raman microscope Laser Spectroscopy Labs Renishaw InVia Raman microscope Operation instructions 1. Turn On the power switch, system power switch is located towards the back of the system on the right hand side. Wait ~10

More information

:... resolution is about 1.4 μm, assumed an excitation wavelength of 633 nm and a numerical aperture of 0.65 at 633 nm.

:... resolution is about 1.4 μm, assumed an excitation wavelength of 633 nm and a numerical aperture of 0.65 at 633 nm. PAGE 30 & 2008 2007 PRODUCT CATALOG Confocal Microscopy - CFM fundamentals :... Over the years, confocal microscopy has become the method of choice for obtaining clear, three-dimensional optical images

More information

Nanowires for Quantum Optics

Nanowires for Quantum Optics Nanowires for Quantum Optics N. Akopian 1, E. Bakkers 1, J.C. Harmand 2, R. Heeres 1, M. v Kouwen 1, G. Patriarche 2, M. E. Reimer 1, M. v Weert 1, L. Kouwenhoven 1, V. Zwiller 1 1 Quantum Transport, Kavli

More information

R. J. Jones Optical Sciences OPTI 511L Fall 2017

R. J. Jones Optical Sciences OPTI 511L Fall 2017 R. J. Jones Optical Sciences OPTI 511L Fall 2017 Semiconductor Lasers (2 weeks) Semiconductor (diode) lasers are by far the most widely used lasers today. Their small size and properties of the light output

More information

Be aware that there is no universal notation for the various quantities.

Be aware that there is no universal notation for the various quantities. Fourier Optics v2.4 Ray tracing is limited in its ability to describe optics because it ignores the wave properties of light. Diffraction is needed to explain image spatial resolution and contrast and

More information

FPPO 1000 Fiber Laser Pumped Optical Parametric Oscillator: FPPO 1000 Product Manual

FPPO 1000 Fiber Laser Pumped Optical Parametric Oscillator: FPPO 1000 Product Manual Fiber Laser Pumped Optical Parametric Oscillator: FPPO 1000 Product Manual 2012 858 West Park Street, Eugene, OR 97401 www.mtinstruments.com Table of Contents Specifications and Overview... 1 General Layout...

More information

Spectroscopy Lab 2. Reading Your text books. Look under spectra, spectrometer, diffraction.

Spectroscopy Lab 2. Reading Your text books. Look under spectra, spectrometer, diffraction. 1 Spectroscopy Lab 2 Reading Your text books. Look under spectra, spectrometer, diffraction. Consult Sargent Welch Spectrum Charts on wall of lab. Note that only the most prominent wavelengths are displayed

More information

Microscopic Structures

Microscopic Structures Microscopic Structures Image Analysis Metal, 3D Image (Red-Green) The microscopic methods range from dark field / bright field microscopy through polarisation- and inverse microscopy to techniques like

More information

3D light microscopy techniques

3D light microscopy techniques 3D light microscopy techniques The image of a point is a 3D feature In-focus image Out-of-focus image The image of a point is not a point Point Spread Function (PSF) 1D imaging 1 1 2! NA = 0.5! NA 2D imaging

More information

Add CLUE to your SEM. High-efficiency CL signal-collection. Designed for your SEM and application. Maintains original SEM functionality

Add CLUE to your SEM. High-efficiency CL signal-collection. Designed for your SEM and application. Maintains original SEM functionality Add CLUE to your SEM Designed for your SEM and application The CLUE family offers dedicated CL systems for imaging and spectroscopic analysis suitable for most SEMs. In addition, when combined with other

More information

HR2000+ Spectrometer. User-Configured for Flexibility. now with. Spectrometers

HR2000+ Spectrometer. User-Configured for Flexibility. now with. Spectrometers Spectrometers HR2000+ Spectrometer User-Configured for Flexibility HR2000+ One of our most popular items, the HR2000+ Spectrometer features a high-resolution optical bench, a powerful 2-MHz analog-to-digital

More information

Laser Beam Analysis Using Image Processing

Laser Beam Analysis Using Image Processing Journal of Computer Science 2 (): 09-3, 2006 ISSN 549-3636 Science Publications, 2006 Laser Beam Analysis Using Image Processing Yas A. Alsultanny Computer Science Department, Amman Arab University for

More information

Sabeeh Irfan Ahmad, Physlab, 23 July 2016

Sabeeh Irfan Ahmad, Physlab, 23 July 2016 Horiba ihr550 Spectrometer QuickInstallation and Operation Guide Sabeeh Irfan Ahmad, Physlab, 23 July 2016 The Horiba ihr550 is an imaging spectrometer that can be used both as a spectrograph and as a

More information

Beam Shaping and Simultaneous Exposure by Diffractive Optical Element in Laser Plastic Welding

Beam Shaping and Simultaneous Exposure by Diffractive Optical Element in Laser Plastic Welding Beam Shaping and Simultaneous Exposure by Diffractive Optical Element in Laser Plastic Welding AKL`12 9th May 2012 Dr. Daniel Vogler Page 1 Motivation: Quality and flexibility diffractive spot shaping

More information

A Laser-Based Thin-Film Growth Monitor

A Laser-Based Thin-Film Growth Monitor TECHNOLOGY by Charles Taylor, Darryl Barlett, Eric Chason, and Jerry Floro A Laser-Based Thin-Film Growth Monitor The Multi-beam Optical Sensor (MOS) was developed jointly by k-space Associates (Ann Arbor,

More information

LOS 1 LASER OPTICS SET

LOS 1 LASER OPTICS SET LOS 1 LASER OPTICS SET Contents 1 Introduction 3 2 Light interference 5 2.1 Light interference on a thin glass plate 6 2.2 Michelson s interferometer 7 3 Light diffraction 13 3.1 Light diffraction on a

More information

Fluorescence Imaging of Single Spins in Nitrogen-Vacancy centers using a Confocal Microscope. Advanced Lab Course University of Basel

Fluorescence Imaging of Single Spins in Nitrogen-Vacancy centers using a Confocal Microscope. Advanced Lab Course University of Basel Fluorescence Imaging of Single Spins in Nitrogen-Vacancy centers using a Confocal Microscope Advanced Lab Course University of Basel October 6, 2015 Contents 1 Introduction 2 2 The Confocal Microscope

More information

PhysicsAndMathsTutor.com 1

PhysicsAndMathsTutor.com 1 PhysicsAndMathsTutor.com 1 Q1. Just over two hundred years ago Thomas Young demonstrated the interference of light by illuminating two closely spaced narrow slits with light from a single light source.

More information

plasmonic nanoblock pair

plasmonic nanoblock pair Nanostructured potential of optical trapping using a plasmonic nanoblock pair Yoshito Tanaka, Shogo Kaneda and Keiji Sasaki* Research Institute for Electronic Science, Hokkaido University, Sapporo 1-2,

More information

UltraGraph Optics Design

UltraGraph Optics Design UltraGraph Optics Design 5/10/99 Jim Hagerman Introduction This paper presents the current design status of the UltraGraph optics. Compromises in performance were made to reach certain product goals. Cost,

More information

Automation of Photoluminescence Measurements of Polaritons

Automation of Photoluminescence Measurements of Polaritons Automation of Photoluminescence Measurements of Polaritons Drake Austin 2011-04-26 Methods of automating experiments that involve the variation of laser power are discussed. In particular, the automation

More information

PANalytical X pert Pro Gazing Incidence X-ray Reflectivity User Manual (Version: )

PANalytical X pert Pro Gazing Incidence X-ray Reflectivity User Manual (Version: ) University of Minnesota College of Science and Engineering Characterization Facility PANalytical X pert Pro Gazing Incidence X-ray Reflectivity User Manual (Version: 2012.10.17) The following instructions

More information

Optical Microscopy and Imaging ( Part 2 )

Optical Microscopy and Imaging ( Part 2 ) 1 Optical Microscopy and Imaging ( Part 2 ) Chapter 7.1 : Semiconductor Science by Tudor E. Jenkins Saroj Kumar Patra, Department of Electronics and Telecommunication, Norwegian University of Science and

More information

TRAINING MANUAL. Multiphoton Microscopy LSM 510 META-NLO

TRAINING MANUAL. Multiphoton Microscopy LSM 510 META-NLO TRAINING MANUAL Multiphoton Microscopy LSM 510 META-NLO September 2010 Multiphoton Microscopy Training Manual Multiphoton microscopy is only available on the LSM 510 META-NLO system. This system is equipped

More information

Supplementary Figure 1

Supplementary Figure 1 Supplementary Figure 1 Technical overview drawing of the Roadrunner goniometer. The goniometer consists of three main components: an inline sample-viewing microscope, a high-precision scanning unit for

More information

University of Wisconsin Chemistry 524 Spectroscopic Components *

University of Wisconsin Chemistry 524 Spectroscopic Components * University of Wisconsin Chemistry 524 Spectroscopic Components * In journal articles, presentations, and textbooks, chemical instruments are often represented as block diagrams. These block diagrams highlight

More information

Improved Spectra with a Schmidt-Czerny-Turner Spectrograph

Improved Spectra with a Schmidt-Czerny-Turner Spectrograph Improved Spectra with a Schmidt-Czerny-Turner Spectrograph Abstract For years spectra have been measured using traditional Czerny-Turner (CT) design dispersive spectrographs. Optical aberrations inherent

More information

KEYENCE VKX LASER-SCANNING CONFOCAL MICROSCOPE Standard Operating Procedures (updated Oct 2017)

KEYENCE VKX LASER-SCANNING CONFOCAL MICROSCOPE Standard Operating Procedures (updated Oct 2017) KEYENCE VKX LASER-SCANNING CONFOCAL MICROSCOPE Standard Operating Procedures (updated Oct 2017) 1 Introduction You must be trained to operate the Laser-scanning confocal microscope (LSCM) independently.

More information

Swept-Field User Guide

Swept-Field User Guide Swept-Field User Guide Note: for more details see the Prairie user manual at http://www.prairietechnologies.com/resources/software/prairieview.html Please report any problems to Julie Last (jalast@wisc.edu)

More information

Introduction to the operating principles of the HyperFine spectrometer

Introduction to the operating principles of the HyperFine spectrometer Introduction to the operating principles of the HyperFine spectrometer LightMachinery Inc., 80 Colonnade Road North, Ottawa ON Canada A spectrometer is an optical instrument designed to split light into

More information

EE119 Introduction to Optical Engineering Spring 2003 Final Exam. Name:

EE119 Introduction to Optical Engineering Spring 2003 Final Exam. Name: EE119 Introduction to Optical Engineering Spring 2003 Final Exam Name: SID: CLOSED BOOK. THREE 8 1/2 X 11 SHEETS OF NOTES, AND SCIENTIFIC POCKET CALCULATOR PERMITTED. TIME ALLOTTED: 180 MINUTES Fundamental

More information

Instruction Manual for HyperScan Spectrometer

Instruction Manual for HyperScan Spectrometer August 2006 Version 1.1 Table of Contents Section Page 1 Hardware... 1 2 Mounting Procedure... 2 3 CCD Alignment... 6 4 Software... 7 5 Wiring Diagram... 19 1 HARDWARE While it is not necessary to have

More information

Development of a new multi-wavelength confocal surface profilometer for in-situ automatic optical inspection (AOI)

Development of a new multi-wavelength confocal surface profilometer for in-situ automatic optical inspection (AOI) Development of a new multi-wavelength confocal surface profilometer for in-situ automatic optical inspection (AOI) Liang-Chia Chen 1#, Chao-Nan Chen 1 and Yi-Wei Chang 1 1. Institute of Automation Technology,

More information

Supplementary Information for. Surface Waves. Angelo Angelini, Elsie Barakat, Peter Munzert, Luca Boarino, Natascia De Leo,

Supplementary Information for. Surface Waves. Angelo Angelini, Elsie Barakat, Peter Munzert, Luca Boarino, Natascia De Leo, Supplementary Information for Focusing and Extraction of Light mediated by Bloch Surface Waves Angelo Angelini, Elsie Barakat, Peter Munzert, Luca Boarino, Natascia De Leo, Emanuele Enrico, Fabrizio Giorgis,

More information

Laser Telemetric System (Metrology)

Laser Telemetric System (Metrology) Laser Telemetric System (Metrology) Laser telemetric system is a non-contact gauge that measures with a collimated laser beam (Refer Fig. 10.26). It measure at the rate of 150 scans per second. It basically

More information

attocfm I for Surface Quality Inspection NANOSCOPY APPLICATION NOTE M01 RELATED PRODUCTS G

attocfm I for Surface Quality Inspection NANOSCOPY APPLICATION NOTE M01 RELATED PRODUCTS G APPLICATION NOTE M01 attocfm I for Surface Quality Inspection Confocal microscopes work by scanning a tiny light spot on a sample and by measuring the scattered light in the illuminated volume. First,

More information

Systematic Workflow via Intuitive GUI. Easy operation accomplishes your goals faster than ever.

Systematic Workflow via Intuitive GUI. Easy operation accomplishes your goals faster than ever. Systematic Workflow via Intuitive GUI Easy operation accomplishes your goals faster than ever. 16 With the LEXT OLS4100, observation or measurement begins immediately once the sample is placed on the stage.

More information

Leica TCS SP8 Quick Start Guide

Leica TCS SP8 Quick Start Guide Leica TCS SP8 Quick Start Guide Leica TCS SP8 System Overview Start-Up Procedure 1. Turn on the CTR Control Box, EL6000 fluorescent light source for the microscope stand. 2. Turn on the Scanner Power

More information

TriVista. Universal Raman Solution

TriVista. Universal Raman Solution TriVista Universal Raman Solution Why choose the Princeton Instruments/Acton TriVista? Overview Raman Spectroscopy systems can be derived from several dispersive components depending on the level of performance

More information

Make Your Own Digital Spectrometer With Diffraction Grating

Make Your Own Digital Spectrometer With Diffraction Grating Make Your Own Digital Spectrometer With Diffraction Grating T. Z. July 6, 2012 1 Introduction and Theory Spectrums are very useful for classify atoms and materials. Although digital spectrometers such

More information

Polarization Experiments Using Jones Calculus

Polarization Experiments Using Jones Calculus Polarization Experiments Using Jones Calculus Reference http://chaos.swarthmore.edu/courses/physics50_2008/p50_optics/04_polariz_matrices.pdf Theory In Jones calculus, the polarization state of light is

More information

Spectral and Polarization Configuration Guide for MS Series 3-CCD Cameras

Spectral and Polarization Configuration Guide for MS Series 3-CCD Cameras Spectral and Polarization Configuration Guide for MS Series 3-CCD Cameras Geospatial Systems, Inc (GSI) MS 3100/4100 Series 3-CCD cameras utilize a color-separating prism to split broadband light entering

More information

GRENOUILLE.

GRENOUILLE. GRENOUILLE Measuring ultrashort laser pulses the shortest events ever created has always been a challenge. For many years, it was possible to create ultrashort pulses, but not to measure them. Techniques

More information

Supplementary Materials

Supplementary Materials Supplementary Materials In the supplementary materials of this paper we discuss some practical consideration for alignment of optical components to help unexperienced users to achieve a high performance

More information

GaAs polytype quantum dots

GaAs polytype quantum dots GaAs polytype quantum dots Vilgailė Dagytė, Andreas Jönsson and Andrea Troian December 17, 2014 1 Introduction An issue that has haunted nanowire growth since it s infancy is the difficulty of growing

More information

Single-photon excitation of morphology dependent resonance

Single-photon excitation of morphology dependent resonance Single-photon excitation of morphology dependent resonance 3.1 Introduction The examination of morphology dependent resonance (MDR) has been of considerable importance to many fields in optical science.

More information

Eric B. Burgh University of Wisconsin. 1. Scope

Eric B. Burgh University of Wisconsin. 1. Scope Southern African Large Telescope Prime Focus Imaging Spectrograph Optical Integration and Testing Plan Document Number: SALT-3160BP0001 Revision 5.0 2007 July 3 Eric B. Burgh University of Wisconsin 1.

More information

Laser stabilization and frequency modulation for trapped-ion experiments

Laser stabilization and frequency modulation for trapped-ion experiments Laser stabilization and frequency modulation for trapped-ion experiments Michael Matter Supervisor: Florian Leupold Semester project at Trapped Ion Quantum Information group July 16, 2014 Abstract A laser

More information

Experiment 1: Fraunhofer Diffraction of Light by a Single Slit

Experiment 1: Fraunhofer Diffraction of Light by a Single Slit Experiment 1: Fraunhofer Diffraction of Light by a Single Slit Purpose 1. To understand the theory of Fraunhofer diffraction of light at a single slit and at a circular aperture; 2. To learn how to measure

More information

Optical Coherence: Recreation of the Experiment of Thompson and Wolf

Optical Coherence: Recreation of the Experiment of Thompson and Wolf Optical Coherence: Recreation of the Experiment of Thompson and Wolf David Collins Senior project Department of Physics, California Polytechnic State University San Luis Obispo June 2010 Abstract The purpose

More information

Instruction manual and data sheet ipca h

Instruction manual and data sheet ipca h 1/15 instruction manual ipca-21-05-1000-800-h Instruction manual and data sheet ipca-21-05-1000-800-h Broad area interdigital photoconductive THz antenna with microlens array and hyperhemispherical silicon

More information

BEAM HALO OBSERVATION BY CORONAGRAPH

BEAM HALO OBSERVATION BY CORONAGRAPH BEAM HALO OBSERVATION BY CORONAGRAPH T. Mitsuhashi, KEK, TSUKUBA, Japan Abstract We have developed a coronagraph for the observation of the beam halo surrounding a beam. An opaque disk is set in the beam

More information

SUPPLEMENTARY INFORMATION

SUPPLEMENTARY INFORMATION Optically reconfigurable metasurfaces and photonic devices based on phase change materials S1: Schematic diagram of the experimental setup. A Ti-Sapphire femtosecond laser (Coherent Chameleon Vision S)

More information

Surface Finish Measurement Methods and Instrumentation

Surface Finish Measurement Methods and Instrumentation 125 years of innovation Surface Finish Measurement Methods and Instrumentation Contents Visual Inspection Surface Finish Comparison Plates Contact Gauges Inductive / Variable Reluctance (INTRA) Piezo Electric

More information

Imaging Systems Laboratory II. Laboratory 8: The Michelson Interferometer / Diffraction April 30 & May 02, 2002

Imaging Systems Laboratory II. Laboratory 8: The Michelson Interferometer / Diffraction April 30 & May 02, 2002 1051-232 Imaging Systems Laboratory II Laboratory 8: The Michelson Interferometer / Diffraction April 30 & May 02, 2002 Abstract. In the last lab, you saw that coherent light from two different locations

More information

OPT3: Operating Procedure for Horiba Jobin Yvon LabRam Aramis Raman/PL System See LabSpec_6_2 General User Quick Start Guide on the computer desktop

OPT3: Operating Procedure for Horiba Jobin Yvon LabRam Aramis Raman/PL System See LabSpec_6_2 General User Quick Start Guide on the computer desktop OPT3: Operating Procedure for Horiba Jobin Yvon LabRam Aramis Raman/PL System See LabSpec_6_2 General User Quick Start Guide on the computer desktop 1. Log in usage using the SMIF web site 2. Turn power

More information

Instruction manual for T3DS software. Tool for THz Time-Domain Spectroscopy. Release 4.0

Instruction manual for T3DS software. Tool for THz Time-Domain Spectroscopy. Release 4.0 Instruction manual for T3DS software Release 4.0 Table of contents 0. Setup... 3 1. Start-up... 5 2. Input parameters and delay line control... 6 3. Slow scan measurement... 8 4. Fast scan measurement...

More information

MS260i 1/4 M IMAGING SPECTROGRAPHS

MS260i 1/4 M IMAGING SPECTROGRAPHS MS260i 1/4 M IMAGING SPECTROGRAPHS ENTRANCE EXIT MS260i Spectrograph with 3 Track Fiber on input and InstaSpec IV CCD on output. Fig. 1 OPTICAL CONFIGURATION High resolution Up to three gratings, with

More information

FRAUNHOFER AND FRESNEL DIFFRACTION IN ONE DIMENSION

FRAUNHOFER AND FRESNEL DIFFRACTION IN ONE DIMENSION FRAUNHOFER AND FRESNEL DIFFRACTION IN ONE DIMENSION Revised November 15, 2017 INTRODUCTION The simplest and most commonly described examples of diffraction and interference from two-dimensional apertures

More information

Nikon. King s College London. Imaging Centre. N-SIM guide NIKON IMAGING KING S COLLEGE LONDON

Nikon. King s College London. Imaging Centre. N-SIM guide NIKON IMAGING KING S COLLEGE LONDON N-SIM guide NIKON IMAGING CENTRE @ KING S COLLEGE LONDON Starting-up / Shut-down The NSIM hardware is calibrated after system warm-up occurs. It is recommended that you turn-on the system for at least

More information

Oriel MS260i TM 1/4 m Imaging Spectrograph

Oriel MS260i TM 1/4 m Imaging Spectrograph Oriel MS260i TM 1/4 m Imaging Spectrograph MS260i Spectrograph with 3 Track Fiber on input and InstaSpec CCD on output. The MS260i 1 4 m Imaging Spectrographs are economical, fully automated, multi-grating

More information

Leica TCS SP8 Quick Start Guide

Leica TCS SP8 Quick Start Guide Leica TCS SP8 Quick Start Guide Leica TCS SP8 System Overview Start-Up Procedure 1. Turn on the CTR Control Box, Fluorescent Light for the microscope stand. 2. Turn on the Scanner Power (1) on the front

More information

Confocal Raman Microscopy (WITec Alpha 300R)

Confocal Raman Microscopy (WITec Alpha 300R) Confocal Raman Microscopy (WITec Alpha 300R) Please refer to Witec Alpha300R Confocal Raman Microscope User Manual for the details of the operating procedure. Sample preparation 1. Attach your sample on

More information

Supplementary Materials for

Supplementary Materials for advances.sciencemag.org/cgi/content/full/4/2/e1700324/dc1 Supplementary Materials for Photocarrier generation from interlayer charge-transfer transitions in WS2-graphene heterostructures Long Yuan, Ting-Fung

More information

Zeiss 780 Training Notes

Zeiss 780 Training Notes Zeiss 780 Training Notes Turn on Main Switch, System PC and Components Switches 780 Start up sequence Do you need the argon laser (458, 488, 514 nm lines)? Yes Turn on the laser s main power switch and

More information

NanoSpective, Inc Progress Drive Suite 137 Orlando, Florida

NanoSpective, Inc Progress Drive Suite 137 Orlando, Florida TEM Techniques Summary The TEM is an analytical instrument in which a thin membrane (typically < 100nm) is placed in the path of an energetic and highly coherent beam of electrons. Typical operating voltages

More information

Exp No.(8) Fourier optics Optical filtering

Exp No.(8) Fourier optics Optical filtering Exp No.(8) Fourier optics Optical filtering Fig. 1a: Experimental set-up for Fourier optics (4f set-up). Related topics: Fourier transforms, lenses, Fraunhofer diffraction, index of refraction, Huygens

More information

ADVANCED OPTICS LAB -ECEN 5606

ADVANCED OPTICS LAB -ECEN 5606 ADVANCED OPTICS LAB -ECEN 5606 Basic Skills Lab Dr. Steve Cundiff and Edward McKenna, 1/15/04 rev KW 1/15/06, 1/8/10 The goal of this lab is to provide you with practice of some of the basic skills needed

More information

STEM Spectrum Imaging Tutorial

STEM Spectrum Imaging Tutorial STEM Spectrum Imaging Tutorial Gatan, Inc. 5933 Coronado Lane, Pleasanton, CA 94588 Tel: (925) 463-0200 Fax: (925) 463-0204 April 2001 Contents 1 Introduction 1.1 What is Spectrum Imaging? 2 Hardware 3

More information

WITec Alpha 300R Quick Operation Summary October 2018

WITec Alpha 300R Quick Operation Summary October 2018 WITec Alpha 300R Quick Operation Summary October 2018 This document is frequently updated if you feel information should be added, please indicate that to the facility manager (currently Philip Carubia,

More information

Infrared Single Shot Diagnostics for the Longitudinal. Profile of the Electron Bunches at FLASH. Disputation

Infrared Single Shot Diagnostics for the Longitudinal. Profile of the Electron Bunches at FLASH. Disputation Infrared Single Shot Diagnostics for the Longitudinal Profile of the Electron Bunches at FLASH Disputation Hossein Delsim-Hashemi Tuesday 22 July 2008 7/23/2008 2/ 35 Introduction m eb c 2 3 2 γ ω = +

More information

Nikon C1si Spectral Laser Scanning Confocal Microscope. User Guide

Nikon C1si Spectral Laser Scanning Confocal Microscope. User Guide Nikon C1si Spectral Laser Scanning Confocal Microscope User Guide Contents: C1Si Turn-On/ShutDown Procedures... 2 Overview... 4 Setup for epi-illumination to view through the eyepieces:... 5 Setup for

More information

Presented by Jerry Hubbell Lake of the Woods Observatory (MPC I24) President, Rappahannock Astronomy Club

Presented by Jerry Hubbell Lake of the Woods Observatory (MPC I24) President, Rappahannock Astronomy Club Presented by Jerry Hubbell Lake of the Woods Observatory (MPC I24) President, Rappahannock Astronomy Club ENGINEERING A FIBER-FED FED SPECTROMETER FOR ASTRONOMICAL USE Objectives Discuss the engineering

More information

ABC Math Student Copy. N. May ABC Math Student Copy. Physics Week 13(Sem. 2) Name. Light Chapter Summary Cont d 2

ABC Math Student Copy. N. May ABC Math Student Copy. Physics Week 13(Sem. 2) Name. Light Chapter Summary Cont d 2 Page 1 of 12 Physics Week 13(Sem. 2) Name Light Chapter Summary Cont d 2 Lens Abberation Lenses can have two types of abberation, spherical and chromic. Abberation occurs when the rays forming an image

More information

The University of Toledo R. Ellingson and M. Heben

The University of Toledo R. Ellingson and M. Heben focal length, f Spectral Measurement Using a Monochromator, Thermopile Detector, and Lock-In Amplifier September 18, 2012 The University of Toledo R. Ellingson and M. Heben Where are We, Where we are Going?

More information

Luminous Equivalent of Radiation

Luminous Equivalent of Radiation Intensity vs λ Luminous Equivalent of Radiation When the spectral power (p(λ) for GaP-ZnO diode has a peak at 0.69µm) is combined with the eye-sensitivity curve a peak response at 0.65µm is obtained with

More information

Photon Diagnostics. FLASH User Workshop 08.

Photon Diagnostics. FLASH User Workshop 08. Photon Diagnostics FLASH User Workshop 08 Kai.Tiedtke@desy.de Outline What kind of diagnostic tools do user need to make efficient use of FLASH? intensity (New GMD) beam position intensity profile on the

More information

Confocal Application Notes Vol. 5 July 2010

Confocal Application Notes Vol. 5 July 2010 Tile Scan Prepared by Myriam Gastard, PhD Application and Technical Support Group, Leica Microsystems, Inc. In this issue of our Confocal Application Notes, proper set up of the Tile function enables you

More information

Microscopy. The dichroic mirror is an important component of the fluorescent scope: it reflects blue light while transmitting green light.

Microscopy. The dichroic mirror is an important component of the fluorescent scope: it reflects blue light while transmitting green light. Microscopy I. Before coming to lab Read this handout and the background. II. Learning Objectives In this lab, you'll investigate the physics of microscopes. The main idea is to understand the limitations

More information

Technical Explanation for Displacement Sensors and Measurement Sensors

Technical Explanation for Displacement Sensors and Measurement Sensors Technical Explanation for Sensors and Measurement Sensors CSM_e_LineWidth_TG_E_2_1 Introduction What Is a Sensor? A Sensor is a device that measures the distance between the sensor and an object by detecting

More information

How-to guide. Working with a pre-assembled THz system

How-to guide. Working with a pre-assembled THz system How-to guide 15/06/2016 1 Table of contents 0. Preparation / Basics...3 1. Input beam adjustment...4 2. Working with free space antennas...5 3. Working with fiber-coupled antennas...6 4. Contact details...8

More information

Chapter 23 Study Questions Name: Class:

Chapter 23 Study Questions Name: Class: Chapter 23 Study Questions Name: Class: Multiple Choice Identify the letter of the choice that best completes the statement or answers the question. 1. When you look at yourself in a plane mirror, you

More information

PHYS 3153 Methods of Experimental Physics II O2. Applications of Interferometry

PHYS 3153 Methods of Experimental Physics II O2. Applications of Interferometry Purpose PHYS 3153 Methods of Experimental Physics II O2. Applications of Interferometry In this experiment, you will study the principles and applications of interferometry. Equipment and components PASCO

More information

Photonic-based spectral reflectance sensor for ground-based plant detection and weed discrimination

Photonic-based spectral reflectance sensor for ground-based plant detection and weed discrimination Research Online ECU Publications Pre. 211 28 Photonic-based spectral reflectance sensor for ground-based plant detection and weed discrimination Arie Paap Sreten Askraba Kamal Alameh John Rowe 1.1364/OE.16.151

More information