Drop Cable Product Catalog

Size: px
Start display at page:

Download "Drop Cable Product Catalog"

Transcription

1 Drop Cable Product Catalog

2 Table of Contents Drop Cable Product Catalog The Basics of CommScope Drop Cable... 2, 3 Drop Cable Reel Dimensions...4 Drop Cable Packaging Information... 4, 5 Explanation of Drop Cable Construction Code...5 Minimum Purchasing Quantity...6 Freight Policy...6 Terms and Conditions...6 Cable Construction Illustrations Series - Standard, Tri-Shield and Super-Shield Constructions... 8, 9 6 Series - Standard, Tri-Shield and Super-Shield Constructions... 10, 11 7 Series - Standard, Tri-Shield and Super-Shield Constructions... 12, Series - Standard, Tri-Shield and Super-Shield Constructions... 14, 15 NEC Category Drop Cables Riser Series (CATVR)... 16, 17 Plenum Series (CATVP)... 18, 19 Headend Cables F59 HEC-2, F59 HEC/ , 21 MultiReach TM Cables... 22, 23 Thank You......for your interest in CommScope drop cable products. You are the reason we are the world leader in coaxial cable. Our new catalog includes the products which you request most often. However, if you do not see the product that you need listed in this catalog, contact the sales representative in your area or contact our Customer Service Department at: Fax: International Fax: CommScope, Inc. of North Carolina.

3 The Basics of CommScope Coaxial DropCable...How it works and what you need It is a complete family of products serving a variety of applications, such as INDOOR, AERIAL, UNDERGROUND, and MULTIPURPOSE. Aerial Cable PVC jacket with integrated messenger. Order Size Shielding Jacket Color Packaging F6 60 BVM Black Reel F TS (F6), TS (F11) SS Integrated Messenger Specs Size Messenger Minimum Breaking Diameter Strength of Messenger F in. 180 lbs. / 82Kgf F in. 365 lbs. / 166 Kgf The BASIC products are available in four shielding types to meet your specific needs. You will benefit by receiving CommScope quality products and unmatched customer service at low prices and improved availability. Orders for BASIC products can be made in small quantity (as little as 4Kft for F11 and 9Kft for F6). Limiting your purchases to the BASIC products will also simplify your purchasing and inventory control. In case you have a unique application that requires special cable, we will continue to offer the industry s broadest product line. Indoor Cable Flame retardant PVC jacket. Meets NEC Article 820 V Rating (UL listed). Available in two packaging options: Reel or CommPak box (F6 only) Available in two jacket colors: Black or Neutral. Order Size Shielding Jacket Color Packaging F6 60 BVV Black Reel F11 90 Neutral Box (F6 Only) 77TS (F6), TS (F11) SS Multipurpose Cable PVC jacket for use as a temporary drop or in various applications. Order Size Shielding Jacket Color Packaging F6 60 BV Black Reel F TS (F6), TS (F11) SS Underground Cable Rugged PE jacket with floodant to prevent corrosion and moisture ingress if the jacket is damaged. Cable is printed with symbol to identify as telecommunications cable. Order Size Shielding Jacket Color Packaging F6 60 BEF Black Reel F TS (F6), TS (F11) SS 2 For more information, call , fax or visit our website at

4 Size Attenuation is primarily a function of cable size. Basic products are available in the two most widely used sizes, 6 and series cable will meet most of your needs. For longer drops, choose 11 due to the lower attenuation values. Basic products feature copper clad steel* center conductor and foam polyethylene dielectric. Attenuation (@ 68 F [20 C]) Frequency 6 Series 11 Series (MHz) db/100 ft db/100 m db/100 ft db/100 m Other Electrical and Mechanical Characteristics Impedance: 75 ohms Velocity of Propogation: 85% *F11 with integrated messenger features a copper clad aluminum center conductor. Shielding The minimum recommended shielding for drop cable is an inner shield of aluminum-polypropylene-aluminum laminated tape bonded to the dielectric and a 60 percent braid of 34 AWG bare aluminum braid wire. This level of shielding is adequate for most of your applications and meets SCTE requirements. Additional shielding is available to provide greater protection against signal ingress and egress. All Basic Products are available in 4 shielding options: Bonded tape + 60 percent braid Bonded tape + 90 percent braid Jacket High quality PVC with flame retardant for indoor applications. PVC for outdoor aerial applications. PE for underground applications to resist abrasion and cuts. Bonded tape + 77 percent braid (F6) + tape (TriShield) + 60 percent braid (F11) Bonded tape + 60 percent braid + tape + 40 percent braid (SuperShield) For more information, call , fax or visit our website at 3

5 Drop Cable Reel Dimensions T F D F = Flange Diameter D = Drum Diameter T = Traverse inside distance between flanges F x D x T Flange Drum Traverse Note: T is inside dimension, not overall width. Drop Cable Packaging Information 6 Series Reel Dimensions Package Dimensions Product Type (F x D x T) Reels/Pkg (l x w x h) Inches cm Inches cm Single 12 x 4 x x 10 x x 36 x x 91 x 112 Single Messenger 14½ x 4 x x 10 x x 44 x x 112 x 104 Single Tri-Shield 12 x 4 x x 10 x x 36 x x 91 x 112 Single Super-Shield 14½ x 4 x x 10 x x 44 x x 112 x Series Reel Dimensions Package Dimensions Product Type (F x D x T) Reels/Pkg (l x w x h) Inches cm Inches cm Single 18 x 6 x x 15 x x 36 x x 91 x 104 Single Messenger 22 x 6 x x 15 x x 44 x x 112 x 104 Single Tri-Shield 18 x 6 x x 15 x x 36 x x 91 x 104 Single Super-Shield 18 x 6 x x 15 x x 36 x x 91 x For more information, call , fax or visit our website at

6 Drop Cable Packaging Information 59 Series Reel Dimensions Package Dimensions Product Type (F x D x T) Reels/Pkg (l x w x h) Inches cm Inches cm Single 12 x 4 x 9 30 x 10 x x 36 x x 91 x 89 Single Messenger 14½ x 4 x x 10 x x 44 x x 112 x 104 Single Tri-Shield 12 x 4 x 9 30 x 10 x x 36 x x 91 x 89 Single Super-Shield 12 x 4 x12 37 x 10 x x 36 x x 91 x 112 Dual 16 x 6 x x 15 x x 42 x x 107 x 104 Dual Messenger 18 x 6 x x 15 x x 36 x x 91 x 104 Dual Tri-Shield 16 x 6 x x 15 x x 42 x x 107 x 104 Dual Super-Shield 18 x 6 x x 15 x x 36 x x 91 x Series Reel Dimensions Package Dimensions Product Type (F x D x T) Reels/Pkg (l x w x h) Inches cm Inches cm Single 14½ x 4 x x 10 x x 44 x x 112 x 104 Single Messenger 18 x 6 x x 15 x x 36 x x 91 x 104 Single Tri-Shield 14½ x 4 x x 10 x x 44 x x 112 x 104 Single Super-Shield 18 x 6 x x 15 x x 42 x x 107 x 104 Dual 30 x 12 x x 30 x x 44 x x 112 x 104 Explanation of Drop Cable Product Codes Prefix F = Gas Expanded Polyethylene Dielectric 2 = Dual Cable 59, 6 = Drop Cable Series 7, 11 F2-660BVM Foam Messenger Dual Cable Polyvinylchloride Jacket 6 Drop Cable Series Bonded % Braid Coverage F660BEF Foam Flooding Compound 6 Drop Cable Series Polyethylene Jacket Bonded % Braid Coverage F6SSVR Foam Riser 6 Drop Cable Series Polyvinylchloride Jacket Super-Shield Foam Dual Cable F2-660BV-BW BrightWire TM Polyvinylchloride Jacket 6 Drop Cable Series Bonded % Braid Coverage Suffix First two = Percentage of Braid Coverage digits e.g. 53, 60, 67, 90, 95 B = Bonded Foil E = Polyethylene Jacket V = Polyvinylchloride Jacket M = Messenger F = Flooded SS = Super-Shield TS = Tri-Shield BW= BrightWire TM APD= Amorphous Polypropylene Drop V = NEC CATV R = NEC CATVR CMH= CSA Flame Test FT-1 CMG= CSA Flame Test FT-4 For more information, call , fax or visit our website at 5

7 Minimum Purchase Quantity BASIC Products Size Round and Messenger Reels Boxes F6 9 a 16 F11 4 N/A Basic Products available in SMALL Quantity Purchases. a Exception: Minimum reel quantity for F6SSVM is 8. OTHER Products CommScope offers a wide variety of products for your unique applications. Higher minimum quantity is required. Options available include custom print, jacket color, sequential marking, etc. Additional charges may apply for these features. Size Round and Messenger Dual Multi-Reach Reels Boxes Coils b Reels Only Reels Only F59 27 (9) 32 (16) 36 (12) 48 (12) 48 (12) F6 27 (9) c 32 (16) 36 (12) 48 (12) 48 (12) F11 24 (4) N/A N/A 48 (12) 48 (12) Example: The minimum order quantity for F6 is 27 reels (or 27,000 ft). For a quantity greater than 27, increments of 9 should be used (36, 45, 54, etc.). b Indicates the minimum number of coils per order. Actual footage per coil varies by product. c Exception: Minimum reel quantity for F6SSVM is 24 (8). Freight Policy Shipments of $5,000 or more are f.o.b. factory, freight allowed if destination is within the continental United States. Shipments of less than $5,000 are f.o.b. factory. Standard lengths are 1,000 feet (304.8 meters) plus or minus 10% for reels and CommPak boxes. Standard length per coil varies by product. Not more than 5% of each shipment shall be other than standard lengths, with no lengths shorter than 500 feet (152 meters) on 1,000 foot (304.8 meters) reels. Orders for custom print may receive lengths down to 300 feet. Method of shipment at discretion of shipper. Inspection and final acceptance shall be made at factory prior to shipment. Terms and Conditions On approved credit, net 30 days from date of invoice; 1.5% finance charge equivalent to 18% per annum will be added after due date. All orders subject to acceptance at factory and will be billed at price in effect at time of shipment. Prices, discounts, terms conditions and specifications are subject to change without notice. 6 For more information, call , fax or visit our website at

8 Drop Cable Constructions Standard Shield Jacket Aluminum Braided Shield Center Conductor Flooded Dielectric Bonded Aluminum Foil Shield Flooding Compound Tri-Shield Additional Aluminum Foil Shield Super-Shield (Quad) Messengered Additional Aluminum Braided Shield Steel Messenger Dual Siamese Construction Dual Messengered For more information, call , fax or visit our website at 7

9 59 Series Drop Cable Descriptions Bonded Foil Standard Construction 67% BRAID Shipping Wt. F5967BV Bonded foil, 67% braid, PVC jacket. 28 F5967BVV Bonded foil, 67% braid, flame retardant PVC jacket. Meets NEC Article 820 V Rating. (UL listed) 28 F5967BVM Bonded foil, 67% braid, PVC jacket,.051 inch messenger. 43 F5967BEF Bonded foil, 67% braid, flooded for underground, PE jacket. 24 F2-5967BVV Dual cable, bonded foil, 67% braid, flame retardant PVC jacket. Meets NEC Article 820 V 60 Rating. (UL listed). 95% BRAID F5995BV Bonded foil, 95% braid, PVC jacket. 29 F5995BVV Bonded foil, 95% braid, flame retardant PVC jacket. Meets NEC Article 820 V Rating. (UL listed) 30 F5995BVM Bonded foil, 95% braid, PVC jacket,.051 inch messenger. 44 F5995BEF Bonded foil, 95% braid, flooded for underground, PE jacket. 26 Bonded Foil Tri-Shield Construction 67% BRAID Shipping Wt. F59TSV Bonded foil, 67% braid, non-bonded tape, PVC jacket. 29 F59TSVV Bonded foil, 67% braid, non-bonded tape, flame retardant PVC jacket. Meets NEC Article 820 V Rating. (UL listed) 29 F59TSVM Bonded foil, 67% braid, non-bonded tape, PVC jacket,.051 messenger. 43 F59TSEF Bonded foil, 67% braid, non-bonded tape, flooded for underground, PE jacket. 25 F2-59TSVV Dual cable, bonded foil, 67% braid, non-bonded tape, flame retardant PVC jacket. Meets Article V Rating. (UL listed) Bonded Foil Super-Shield Construction 53% + 35% BRAID Shipping Wt. F59SSV Bonded foil, 53% braid, non-bonded tape, 35% braid, PVC jacket. 34 F59SSVV Bonded foil, 53% braid, non-bonded tape, 35% braid, flame retardant PVC jacket. Meets NEC Article 820 V Rating. (UL listed) 34 F59SSVM Bonded foil, 53% braid, non-bonded tape, 35% braid, PVC jacket,.051 messenger. 49 F59SSEF Bonded foil, 53% braid, non-bonded tape, 35% braid, flooded for underground, PE jacket. 28 F2-59SSVV Dual cable, bonded foil, 53% braid, non-bonded tape, 35% braid, flame retardant PVC jacket. 72 Meets NEC Article 820 V Rating. (UL listed) 8 For more information, call , fax or visit our website at

10 59 Series Drop Cable Specifications Standard Construction 20 gauge [0.032 in. (0.81 mm)] copper covered steel center conductor; gas expanded polyethylene dielectric; inner shield aluminum-polypropylene-aluminum laminated tape with overlap bonded to dielectric; outer shield of 34 AWG bare aluminum braid wire; jacket of black polyvinylchloride or polyethylene (flooded). Nominal O.D in. (6.10 mm). Physical Dimensions Component Standard Shield Tri-Shield Super-Shield Inches mm Inches mm Inches mm Nominal Center Conductor Diameter Nominal Diameter Over Dielectric Nominal Diameter Over First Shield (Tape) Nominal Diameter Over Jacket Nominal Jacket Wall Thickness Nominal Diameter of Steel Messenger (single) (single) (single) (dual) (dual) (dual) 1.83 Mechanical Characteristics Minimum Breaking lbs. 82kg f Strength of Messenger lbs. 166kg f Electrical Characteristics Nominal Impedance 75 Ohms Nominal Velocity of Propogation 85% Corrosion Resistant Drops (BW & APD) Many products are available with a choice of two corrosion resistant treatments. Contact our sales and marketing office for specific information. BrightWire TM is a dry, anti-corrosive treatment that chemically combines with metal components to form a protective shield against water and subsequent corrosion. (Exceeds the SCTE requirement for corrosion resistant cable.) APD is a non-flowing, amorphous polypropylene flooding compound. APD meets NEC Article 830 V Rating. (UL listed) Specify BrightWire or APD when ordering product: Attenuation [@ 68 F. (20 C.)] Frequency Maximum Maximum (MHz) (db/100 ft.) (db/100 m) / Channel / Channel / Channel / Channel Specifications subject to change without notice. F5967BV-BW (BrightWire TM anti-corrosive treatment) F5967BV-APD (APD anti-corrosive treatment) For more information, call , fax or visit our website at 9

11 6 Series Drop Cable Descriptions Bonded Foil Standard Construction 60% BRAID Shipping Wt. F660BV Bonded foil, 60% braid, PVC jacket. 33 F660BVV Bonded foil, 60% braid, flame retardant PVC jacket. Meets NEC Article 820 V Rating. (UL listed) 34 F660BVM Bonded foil, 60% braid, PVC jacket,.051 inch messenger. 48 F660BEF Bonded foil, 60% braid, flooded for underground, PE jacket. 30 F2-660BVV Dual cable, bonded foil, 60% braid, flame retardant PVC jacket. Meets NEC Article 820 V Rating. 71 (UL listed) F660BVV-APD Bonded foil, 60% braid, flame retardant PVC jacket, amorphous polypropylene flooding compound (non-flowing). Meets NEC Article 820 V Rating. (UL listed) 34 90% BRAID F690BV Bonded foil, 90% braid, PVC jacket. 34 F690BVV Bonded foil, 90% braid, flame retardant PVC jacket. Meets NEC Article 820 V Rating. (UL listed) 34 F690BVM Bonded foil, 90% braid, PVC jacket,.051 inch messenger. 49 F690BEF Bonded foil, 90% braid, flooded for underground, PE jacket. 31 Dual cable, bonded foil, 90% braid, flame retardant PVC jacket. Meets NEC Article 820 V Rating. 73 F2-690BVV (UL listed) Bonded Foil Tri-Shield Construction 60% BRAID Shipping Wt. F6TSV Bonded foil, 60% braid, non-bonded tape, PVC jacket. 34 F6TSVV Bonded foil, 60% braid, non-bonded tape, flame retardant PVC jacket. Meets NEC Article 820 V Rating. (UL listed) 34 F677TSVV Bonded foil, 77% braid, non-bonded tape, flame retardant PVC jacket. Meets NEC Article 820 V Rating. (UL listed) 34 F6TSVM Bonded foil, 60% braid, non-bonded tape, PVC jacket,.051 messenger. 53 F6TSEF Bonded foil, 60% braid, non-bonded tape, flooded for underground, PE jacket. 36 F2-6TSVV Dual cable, bonded foil, 60% braid, non-bonded tape, flame retardant PVC jacket. Meets Article 820 V Rating. (UL listed) 68 F6TSVV-APD Bonded tape, 60% braid, non-bonded tape, flame retardant PVC jacket, amorphous 32 polypropylene flooding compound (non-flowing). Meets NEC Article 820 V Rating. (UL listed) Bonded Foil Super-Shield Construction 60% + 42% BRAID Shipping Wt. F6SSV Bonded foil, 60% braid, non-bonded tape, 42% braid, PVC jacket. 44 F6SSVV Bonded foil, 60% braid, non-bonded tape, 42% braid, flame retardant PVC jacket. Meets NEC Article 820 V Rating. (UL listed) 44 F6SSVM Bonded foil, 60% braid, non-bonded tape, 42% braid, PVC jacket,.051 messenger. 62 F6SSEF Bonded foil, 60% braid, non-bonded tape, 42% braid, flooded for underground, PE jacket. 38 F2-6SSVV F6SSVV-APD Dual cable, bonded foil, 60% braid, non-bonded tape, 42% braid, flame retardant PVC jacket. 87 Meets NEC Article 820 V Rating. (UL listed) Bonded foil, 60% braid, non-bonded tape, 42% braid, flame retardant PVC jacket, amorphous 45 polypropylene flooding compound (non-flowing). Meets NEC Article 820 V Rating. (UL listed) 10 For more information, call , fax or visit our website at

12 6 Series Drop Cable Specifications Standard Construction 18 gauge [0.040 in. (1.02 mm)] copper covered steel center conductor; gas expanded polyethylene dielectric; inner shield aluminum-polypropylene-aluminum laminated tape with overlap bonded to dielectric; outer shield of 34 AWG bare aluminum braid wire; jacket of black polyvinylchloride or polyethylene (flooded). Nominal O.D in. (6.91 mm). Physical Dimensions Component Standard Shield Tri-Shield Super-Shield Inches mm Inches mm Inches mm Nominal Center Conductor Diameter Nominal Diameter Over Dielectric Nominal Diameter Over First Shield (Tape) Nominal Diameter Over Jacket Nominal Jacket Wall Thickness Nominal Diameter of Steel Messenger (single) (single) (single) (dual) (dual) (dual) 1.83 Mechanical Characteristics Minimum Breaking lbs. 82kg f Strength of Messenger lbs. 166kg f Electrical Characteristics Nominal Impedance 75 Ohms Nominal Velocity of Propogation 85% Corrosion Resistant Drops (APD & CRD) Additional products may be available with the corrosion resistant treatment. Contact our sales and marketing office for additional information. Specifications subject to change without notice. Attenuation [@ 68 F. (20 C.)] Frequency Maximum Maximum (MHz) (db/100 ft.) (db/100 m) / Channel / Channel / Channel / Channel For more information, call , fax or visit our website at 11

13 7 Series Drop Cable Descriptions Bonded Foil Standard Construction 60% BRAID Shipping Wt. F760BV Bonded foil, 60% braid, PVC jacket. 58 F760BVV Bonded foil, 60% braid, flame retardant PVC jacket. Meets NEC Article 820 V Rating. (UL listed) 58 F760BVM Bonded foil, 60% braid, PVC jacket,.072 inch messenger. 81 F760BEF Bonded foil, 60% braid, flooded for underground, PE jacket. 52 F2-760BVV F760BVV-APD Dual cable, bonded foil, 60% braid, flame retardant PVC jacket. Meets NEC Article 820 V Rating.118 (UL listed) Bonded foil, 60% braid, flame retardant PVC jacket, amorphous polypropylene flooding 58 compound (non-flowing). Meets NEC Article 820 V Rating. (UL listed) Bonded Foil Tri-Shield Construction 60% BRAID Shipping Wt. F7TSV Bonded foil, 60% braid, non-bonded tape, PVC jacket. 58 F7TSVV Bonded foil, 60% braid, non-bonded tape, flame retardant PVC jacket. Meets NEC Article V Rating. (UL listed) F7TSVM Bonded foil, 60% braid, non-bonded tape, PVC jacket,.072 messenger. 81 F7TSEF Bonded foil, 60% braid, non-bonded tape, flooded for underground, PE jacket. 52 F2-7TSVV F7TSVV-APD Dual cable, bonded foil, 60% braid, non-bonded tape, flame retardant PVC jacket. Meets Article V Rating. (UL listed) Bonded tape, 60% braid, non-bonded tape, flame retardant PVC jacket, amorphous 58 polypropylene flooding compound (non-flowing). Meets NEC Article 820 V Rating. (UL listed) Bonded Foil Super-Shield Construction 60% + 40% BRAID Shipping Wt. F7SSV Bonded foil, 60% braid, non-bonded tape, 40% braid, PVC jacket. 64 F7SSVM Bonded foil, 60% braid, non-bonded tape, 40% braid, PVC jacket,.072 messenger. 87 F7SSEF Bonded foil, 60% braid, non-bonded tape, 40% braid, flooded for underground, PE jacket. 56 F7SSVV F2-7SSVV F7SSVV-APD Bonded foil, 60% braid, non-bonded tape, 40% braid, flame retardant PVC jacket. Meets 65 NEC Article 820 V Rating. (UL listed) Dual cable, bonded foil, 60% braid, non-bonded tape, 40% braid, flame retardant PVC jacket. 132 Meets NEC Article 820 V Rating. (UL listed) Bonded foil, 60% braid, non-bonded tape, 40% braid, flame retardant PVC jacket, amorphous 65 polypropylene flooding compound (non-flowing). Meets NEC Article 820 V Rating. (UL listed) 12 For more information, call , fax or visit our website at

14 7 Series Drop Cable Specifications Standard Construction 16 gauge [0.051 in. (1.29 mm)] copper covered steel center conductor; gas expanded polyethylene dielectric; inner shield aluminum-polypropylene-aluminum laminated tape with overlap bonded to dielectric; outer shield of 34 AWG bare aluminum braid wire; jacket of black polyvinylchloride or polyethylene (flooded). Nominal O.D in. (8.08 mm). Physical Dimensions Component Standard Shield Tri-shield Super-Shield Inches mm Inches mm Inches mm Nominal Center Conductor Diameter Nominal Diameter Over Dielectric Nominal Diameter Over First Shield (Tape) Nominal Diameter Over Jacket Nominal Jacket Wall Thickness Nominal Diameter of Steel Messenger (single) (single) (single) (dual) (dual) (dual) 2.77 Mechanical Characteristics Minimum Breaking lbs. 166kg f Strength of Messenger lbs. 818kg f Electrical Characteristics Nominal Impedance 75 Ohms Nominal Velocity of Propogation 85% Corrosion Resistant Drops (APD & CRD) Additional products may be available with the corrosion resistant treatment. Contact our sales and marketing office for additional information. Specifications subject to change without notice. Attenuation [@ 68 F. (20 C.)] Frequency Maximum Maximum (MHz) (db/100 ft.) (db/100 m) / Channel / Channel / Channel / Channel For more information, call , fax or visit our website at 13

15 11 Series Drop Cable Descriptions Bonded Foil Standard Construction 60% BRAID Shipping Wt. F1160BV Bonded foil, 60% braid, PVC jacket. 73 F1160BVV Bonded foil, 60% braid, flame retardant PVC jacket. Meets NEC Article 820 V Rating. (UL listed) 73 F1160BVM 14 guage copper clad aluminum, bonded foil, 60% braid, PVC jacket,.072 inch messenger. 88 F1160BEF Bonded foil, 60% braid, flooded for underground, PE jacket. 65 F2-1160BVV F1160BVV-APD Dual cable, bonded foil, 60% braid, flame retardant PVC jacket. Meets NEC Article V Rating (UL listed) Bonded foil, 60% braid, flame retardant PVC jacket, amorphous polypropylene flooding 73 compound (non-flowing). Meets NEC Article 820 V Rating. (UL listed) Bonded Foil Tri-Shield Construction 60% BRAID Shipping Wt. F11TSV Bonded foil, 60% braid, non-bonded tape, PVC jacket. 73 F11TSVV F11TSVM Bonded foil, 60% braid, non-bonded tape, flame retardant PVC jacket. Meets NEC Article V Rating. (UL listed) 14 guage copper clad aluminum, bonded foil, 60% braid, non-bonded tape, PVC jacket, inch messenger. F11TSEF Bonded foil, 60% braid, non-bonded tape, flooded for underground, PE jacket. 65 F2-11TSVV F11TSVV-APD Dual cable, bonded foil, 60% braid, non-bonded tape, flame retardant PVC jacket. Meets Article V Rating. (UL listed) Bonded tape, 60% braid, non-bonded tape, flame retardant PVC jacket, amorphous 73 polypropylene flooding compound (non-flowing). Meets NEC Article 820 V Rating. (UL listed) Bonded Foil Super-Shield Construction 60% + 40% BRAID Shipping Wt. F11SSV Bonded foil, 60% braid, non-bonded tape, 40% braid, PVC jacket. 77 F11SSVV Bonded foil, 60% braid, non-bonded tape, 40% braid, flame retardant PVC jacket. Meets 77 NEC Article 820 V Rating. (UL listed) F11SSVM 14 gauge copper clad aluminum, bonded foil, 60% braid, non-bonded tape, 40% braid, 91 PVC jacket,.072 inch messenger. F11SSEF Bonded foil, 60% braid, non-bonded tape, 40% braid, flooded for underground, PE jacket. 67 F2-11SSVM F11SSVV-APD 14 guage copper clad aluminum, dual cable, bonded foil, 60% braid, non-bonded tape, % braid, PVC jacket,.109 inch messenger. Bonded foil, 60% braid, non-bonded tape, 40% braid, flame retardant PVC jacket, amorphous 77 polypropylene flooding compound (non-flowing). Meets NEC Article 820 V Rating. (UL listed) 14 For more information, call , fax or visit our website at

16 11 Series Drop Cable Specifications Standard Construction 14 gauge [0.064 in. (1.63 mm)] copper covered steel center conductor; gas expanded polyethylene dielectric; inner shield aluminum-polypropylene-aluminum laminated tape with overlap bonded to dielectric; outer shield of 34 AWG bare aluminum braid wire; jacket of black polyvinylchloride or polyethylene (flooded). Nominal O.D in. (10.03 mm). Physical Dimensions Component Standard Shield Tri-Shield Super-Shield Inches mm Inches mm Inches mm Nominal Center Conductor Diameter Nominal Diameter Over Dielectric Nominal Diameter Over First Shield (Tape) Nominal Diameter Over Jacket Nominal Jacket Wall Thickness Nominal Diameter of Steel Messenger (single) (single) (single) (dual) (dual) (dual) 2.77 Mechanical Characteristics Minimum Breaking lbs. 166kg f Strength of Messenger lbs. 818kg f Electrical Characteristics Nominal Impedance 75 Ohms Nominal Velocity of Propogation 85% Corrosion Resistant Drops (APD & CRD) Additional products may be available with the corrosion resistant treatment. Contact our sales and marketing office for additional information. Specifications subject to change without notice. Attenuation [@ 68 F. (20 C.)] Frequency Maximum Maximum (MHz) (db/100 ft.) (db/100 m) / Channel / Channel / Channel / Channel For more information, call , fax or visit our website at 15

17 NEC Riser Drop Cable Series Descriptions Flame Retardant PVC Jacket 59 Riser Series - CATVR Construction CodeProduct Description Shipping Wt. (Lbs.) /1000' F5967BVR Bonded tape, 67% braid, flame retardant PVC jacket. 29 F2-5967BVR Dual cable, bonded tape, 67% braid, flame retardant PVC jacket. 62 F5995BVR Bonded tape, 95% braid, flame retardant PVC jacket. 30 F59TSVR Bonded tape, 67% braid, flame retardant PVC jacket. 28 F59SSVR Bonded tape, 67% braid, non-bonded tape, 40% braid, flame retardant PVC 31 jacket. Meets NEC Article 820 Riser Rating (UL listed). 6 Riser Series - CATVR Construction CodeProduct Description Shipping Wt. (Lbs.) /1000' F660BVR Bonded tape, 60% braid, flame retardant PVC jacket. 30 F2-660BVR Dual cable, bonded tape, 60% braid, flame retardant PVC jacket. 66 F690BVR Bonded tape, 90% braid, flame retardant PVC jacket. 33 F6TSVR Bonded tape, 60% braid,non-bonded tape, flame retardant PVC jacket. 32 F6SSVR Bonded tape, 60% braid, non-bonded tape, 40% braid, flame retardant PVC jacket. 44 Meets NEC Article 820 Riser Rating (UL listed). 11 Riser Series - CATVR Shipping Wt. F1160BVR Bonded tape, 60% braid, flame retardant PVC jacket. 73 F11SSVR Bonded tape, 60% braid, non-bonded tape, 60% braid, flame retardant PVC jacket. 78 Meets NEC Article 820 Riser Rating (UL listed). 16 For more information, call , fax or visit our website at

18 NEC Riser Drop Cable Specifications Standard Construction - 59 Riser Series 20 gauge [0.032 in. (0.81 mm)] copper covered steel center conductor; gas expanded polyethylene dielectirc; inner shield aluminum-polypropylene-aluminum laminated tape with overlap bonded to dielectric; outer shield of bare aluminum braid wire; jacket of flame retardant black polyvinylchloride. Nom. O.D in. (6.10 mm). Physical Dimensions Inches mm inches mm Nominal Center Conductor Diameter Nominal Diameter Over Dielectric Nominal Diameter Over First Shield (Tape) Nominal Diameter Over Jacket Nominal Jacket Wall Thickness Electrical Characteristics Nominal Impedance 75 Ohms Nominal Velocity of Propogation 85% Attenuation [@ 68 F. (20 C.)] Frequency Maximum Maximum (MHz) (db/100 ft.) (db/100 m) Standard Construction - 6 Riser Series 18 gauge [ in. (0.91 mm)] copper covered steel center conductor; gas expanded polyethylene dielectric; inner shield aluminum-polypropylene-aluminum laminated tape with overlap bonded to dielectric; outer shield of bare aluminum braid wire; jacket of flame retardant black polyvinylchloride. Nom. O.D in. (6.91 mm). Physical Dimensions Inches mm inches mm Nominal Center Conductor Diameter Nominal Diameter Over Dielectric Nominal Diameter Over First Shield (Tape) Nominal Diameter Over Jacket Nominal Jacket Wall Thickness Electrical Characteristics Nominal Impedance 75 Ohms Nominal Velocity of Propogation 85% Attenuation [@ 68 F. (20 C.)] Frequency (MHz) Maximum (db/100 ft.) Maximum (db/100 m) Standard Construction - 11 Riser Series 14 gauge [0.064 in. (1.63 mm)] copper covered steel center conductor; gas expanded polyethylene dielectric; inner shield aluminum-polypropylene-aluminum laminated tape with overlap bonded to dielectric; outer shield of bare aluminum braid wire; jacket of flame retardant black polyvinylchloride. Nom. O.D in. (10.03 mm). Physical Dimensions Inches mm inches mm Nominal Center Conductor Diameter Nominal Diameter Over Dielectric Nominal Diameter Over First Shield (Tape) Nominal Diameter Over Jacket Nominal Jacket Wall Thickness Electrical Characteristics Nominal Impedance 75 Ohms Nominal Velocity of Propogation 85% Attenuation [@ 68 F. (20 C.)] Frequency Maximum Maximum (MHz) (db/100 ft.) (db/100 m) For more information, call , fax or visit our website at 17

19 NEC Plenum Drop Cable Series Vinyl Jacket Kynar Jacket 59 Plenum Series - CATVP Shipping Wt. 2020K Basic construction, plenum rated jacket, 67% braid V 2022K Basic construction, with additional non-braided laminated tape and braid shield, V plenum rated jacket, 50% and 40% braid. Meets NEC Article 820 Plenum Rating (UL listed). 6 Plenum Series - CATVP Shipping Wt. 2275K Basic construction, plenum rated jacket, 60% braid V Basic construction, plenum rated jacket, 90% braid K Basic construction, with additional non-braided laminated tape and braid shield, V plenum rated jacket, 2-60% braids. Meets NEC Article 820 Plenum Rating (UL listed). 11 Plenum Series - CATVP Shipping Wt. 2285K Basic construction, plenum rated jacket, 60% braid K Basic construction, with additional non-braided laminated tape and braid shield, 85 plenum rated jacket, 2-60% braids. Meets NEC Article 820 Plenum Rating (UL listed). 18 For more information, call , fax or visit our website at

20 NEC Plenum Drop Cable Specifications Standard Construction - 59 Plenum Series 20 gauge [0.032 in. (0.81 mm)] copper covered steel center conductor; gas expanded Teflon dielectric (FEP); inner shield aluminum laminated tape with overlap bonded to dielectric; outer shield of 34 AWG bare aluminum braid wire; jacket of plenum rated material. Nom. O.D in. (5.26 mm). Physical Dimensions Inches mm inches mm Nominal Center Conductor Diameter Nominal Diameter Over Dielectric Nominal Diameter Over First Shield (Tape) Nominal Diameter Over Jacket Nominal Jacket Wall Thickness Attenuation [@ 68 F. (20 C.)] Frequency Maximum Maximum (MHz) (db/100 ft.) (db/100 m) Electrical Characteristics Nominal Impedance 75 Ohms Nominal Velocity of Propogation 84% Standard Construction - 6 Plenum Series 18 gauge [0.040 in. (1.02 mm)] copper covered steel center conductor; gas expanded Teflon dielectric (FEP); inner shield aluminum laminated tape with overlap bonded to dielectric; outer shield of 34 AWG bare aluminum braid wire; jacket of plenum rated material. Nom. O.D in. (6.20 mm). Physical Dimensions Inches mm inches mm Nominal Center Conductor Diameter Nominal Diameter Over Dielectric Nominal Diameter Over First Shield (Tape) Nominal Diameter Over Jacket Nominal Jacket Wall Thickness Attenuation [@ 68 F. (20 C.)] Frequency Maximum Maximum (MHz) (db/100 ft.) (db/100 m) Electrical Characteristics Nominal Impedance 75 Ohms Nominal Velocity of Propogation 84% Standard Construction - 11 Plenum Series 14 gauge [0.064 in. (1.45 mm)] copper covered steel center conductor; gas expanded Teflon dielectric (FEP); inner shield aluminum laminated tape with overlap bonded to dielectric; outer shield of 34 AWG bare aluminum braid wire; jacket of plenum rated material. Nom. O.D. of in. (8.92 mm). Physical Dimensions Inches mm inches mm Nominal Center Conductor Diameter Nominal Diameter Over Dielectric Nominal Diameter Over First Shield (Tape) Nominal Diameter Over Jacket Nominal Jacket Wall Thickness Attenuation [@ 68 F. (20 C.)] Frequency Maximum Maximum (MHz) (db/100 ft.) (db/100 m) Electrical Characteristics Nominal Impedance 75 Ohms Nominal Velocity of Propogation 82% For more information, call , fax or visit our website at 19

21 Headend Drop Cable Series F59 HEC-2 Headend Cable F59 HEC-2 Headend Cable Basic Construction 20 gauge [Nominal in. (0.81 mm)] silver plated copper covered steel center conductor; gas expanded polyethylene dielectric; inner shield aluminum-polypropylene-aluminum laminated tape with overlap bonded to dielectric; 34 AWG aluminum braid; aluminum-polypropylene-aluminum non-bonded tape; 34 AWG aluminum braid, jacket of black flame retardant polyvinylchloride meeting NEC Article 820 (UL listed), CATV category; Nominal O.D in. (6.73 mm). F59 HEC/3-22 Headend Cable F59 HEC/3-22 Headend Cable Basic Construction 20 gauge [Nominal in. (0.81 mm)] silver plated copper covered steel center conductor; gas expanded polyethylene dielectric; inner shield aluminum-propylene-aluminum laminated tape with overlap bonded to dielectric; 34 AWG aluminum braid; 34 AWG aluminum braid; jacket of black flame retardant polyvinylchloride meeting NEC Article 820 (UL listed), CATV category; Nominal O.D in. (6.73 mm). Audio Pair: three 22 AWG bare copper, polyethylene insulation; 24 AWG tin-copper drain and polyester rip cord with aluminum shield on each pair; dual construction. 20 For more information, call , fax or visit our website at

22 Headend Drop Cable Specifications Basic Construction Center Conductor 20 AWG (.032 in.) silver plated copper covered steel center conductor. Dielectric Gas expanded polyethylene. Shield 1. Bonded laminated aluminum tape AWG aluminum braid, 95% coverage. 3. Laminated aluminum tape AWG aluminum braid, 95% coverage. Jacket Flame retardant polyvinylchloride available in 12 colors: black, white, gray, green, brown, red, yellow, blue, orange, violet, aqua and rose. Audio Pair (F59 HEC/3-22 Only) Three Pair: 22 AWG (.0285 in.) bare copper Insulation: High density polyethylene. Drain: 24 AWG (.024 in.) tinned copper Ripcord: Polyester. Shielding: Aluminum (each pair). Identification: Color coding (std.): red/white, red/black, red/green. Reel: 14½ x 6 x 13. Length: 1000 ft. Cable Weight: 70 lbs./1000 ft. Electrical Characteristics Nominal Impedance 75 Ohms Capacitance 16.2 Velocity of Propogation 85% NOTE: Test reports are included on reels. Nominal Dimensions Conductor inches... (0.81 mm) Dielectric inches... (3.66 mm) Diameter Over 1st Shield inches... (3.84 mm) Diameter Over 2nd Shield inches... (4.57 mm) Diameter Over 3rd Shield inches... (4.70 mm) Diameter Over 4th Shield inches... (5.46 mm) Diameter Over Jacket inches... (6.86 mm) Attenuation [@ 68 F. (20 C.)] Frequency Maximum Maximum (MHz) (db/100 ft.) (db/100 m) / Channel / Channel / Channel / Channel For more information, call , fax or visit our website at 21

23 MultiReach Drop Cable Series TM F6, F7 & F11 Series Description F Series 6, 7 or 11 Series coax with one (1) thru six (6) 22 AWG solid copper twisted pair conductors. Available in underground design with polyethylene flooded jacket (Amorphous Polypropylene [APD] and Extended Thermoplastic Rubber [ETPR]) or aerial design with polyvinylchloride (PVC) jacket and inch galvanized steel messenger for self support. Standard Shield Coax Construction Bonded aluminum tape, 60% aluminum braid, jacket material. Super Shield (SS) Coax Construction Bonded aluminum tape, 60% aluminum braid, non-bonded aluminum tape, 42% aluminum braid, jacket material. Drop Cable MultiReach TM F Series 6, 7, or 11 Series coax with one (1) thru six (6) 22 Awg solid copper twisted paired conductors. Available in underground design with polyethylene (PE) flooded jacket (APD) or aerial and indoor designs with polyvinylchloride (PVC). Standard Coax* Aerial Coax* Underground Coax** F660BV F660BVM F660BE-APD F690BV F690BVM F690BE-APD F6SSV F6SSVM F6SSE-APD F760BV F760BVM F760BE-APD F7SSV F7SSVM F7SSE-APD F1160BV F1160BVM F1160BE-APD F1190BV F1190BVM F1190BE-APD F11SSV F11SSVM F11SSE-APD NOTES: Coax construction + # and awg of pairs = MultiReach TM F11SSE-APD + 5/22 (5 pairs of 22 awg conductors) = F11SSE-APD 5/22 V - Polyvinylcloride (PVC) VV - Flame Retardant PVC Jacket, NEC CATV VM - PVC Jacket with messenger VVM - Flame Retardant PVC jacket with messenger, NEC CATV *PVC jacket MultiReachTM cables are designed to be flooded or non-flooded. For flooded PVC cables, add APD to the end of coax description. APD will also be the floodant used over pairs. BE - Polyethylene Jacket (PE) BE APD - Flooded with PE jacket **PE jacketed MultiReach TM cables are designed to be flooded only, non-flooded not available. ETPR will be the floodant used over pairs unless otherwise requested. PE jacketed MultiReach TM cables with 3-6 pairs are also available with armor over the pairs, PVC not available. 22 For more information, call , fax or visit our website at

24 MultiReach TM Drop Cable Specifications Nominal Diameter over Outer Jacket Coaxial Cable Web Width Pairs Web Width Messenger F660BV F6SSV F760BV F7SSV F1160BV F11SSV Voice Pairs Description 22 AWG solid copper conductor, polyethylene insulation, unshielded twisted pair with rip cord. Solid Conductor 22 AWG ( inches) Number of Pairs Available 1-6 Standard Length 1000 ft/reel Identification Color code chart Pair Number Color Combination 1 Blue & White/Blue Stripe 2 Orange & White/Orange Stripe 3 Green & White/Green Stripe 4 Brown & White/Brown Stripe 5 Slate & White/Slate Stripe 6 Blue & Red/Blue Stripe See pages 7, 9, and 11 for coax construction and transmission data. For more information, call , fax or visit our website at 23

25 Notes

Detailed Specifications & Technical Data

Detailed Specifications & Technical Data Description: Series 11, 14 AWG solid.064" bare copper-covered steel conductor, gas-injected foam polyethylene insulation, Duobond IV quad shield (60% and 40% coverage), PVC jacket Physical Characteristics

More information

Electrical Characteristics Nominal electrical characteristics are shown in Table 1. Attenuation, Comply with ANSI T1.102; discrete values Table 1a.

Electrical Characteristics Nominal electrical characteristics are shown in Table 1. Attenuation, Comply with ANSI T1.102; discrete values Table 1a. 734A COAXIAL CABLE Application Intended for interconnection of transmission and switching systems equipment. Features UL listed as NEC Type CMR and CSA certified as Type CMR. NORDX/CDT 734A coaxial was

More information

COAX 101. Author: Rob Wessels. Vice President of Engineering

COAX 101. Author: Rob Wessels.   Vice President of Engineering COAX 101 Author: Rob Wessels Vice President of Engineering Structured cable systems have very thorough standards for fiber optic and twisted pair installations. The cabling components and installed systems

More information

Detailed Specifications & Technical Data

Detailed Specifications & Technical Data Description: 24 AWG stranded (7x32) TC conductor, Datalene insulation, pairs individually shielded with bonded Beldfoil with a drain wire and have numbered and color-coded PVC jackets, overall Beldfoil

More information

FOR INTERCONNECT AND CROSS-CONNECT APPLICATIONS

FOR INTERCONNECT AND CROSS-CONNECT APPLICATIONS FOR INTERCONNECT AND CROSS-CONNECT APPLICATIONS HIGH SPEED DS-3 & DS-4 CABLES Belden Your Widest Selection for Meeting DS-3 and DS-4 Network Requirements BELDEN, THE CABLE TECHNOLOGY LEADER IN HIGH-SPEED

More information

Detailed Specifications & Technical Data

Detailed Specifications & Technical Data For more Information please call 1-800-Belden1 Description: Banana Peel Composite - (2) Cat 5e 4-pair 24 AWG unshielded plus (2) Series 6 Coax with Duobond IV Quad shield, polyolefin insulation on the

More information

Detailed Specifications & Technical Data

Detailed Specifications & Technical Data For more Information please call 1-800-Belden1 Description: Coax (2-1505A Type) 20 AWG BC, GIFPE isulation, Duofoil plus TC braid (95% cv.), PVC inner jackets. Pairs (4-9451 Type): 22 AWG TC, PP insul.,

More information

Standard Lengths of. Code Ft. m

Standard Lengths of. Code Ft. m M U L T I - C O N D U C T O R C A B L E S 4.15 Overall Braid Shield MIL-W-16878 ( B) s, Shielded and ed Counication and Instruentation Cables 22 AWG Stranded (19x34) TC s.003 (.76) Clear Nylon Skin over

More information

EXTRA-PREMIUM GRADE PVC JACKET FOR EXTENDED CABLE LIFE. 24 AWG (0,23mm 2 ), 7/32 (7x0,20mm), Insulation Thickness: 0.010" (0,25mm)

EXTRA-PREMIUM GRADE PVC JACKET FOR EXTENDED CABLE LIFE. 24 AWG (0,23mm 2 ), 7/32 (7x0,20mm), Insulation Thickness: 0.010 (0,25mm) XTRA GUARD 1 MULTICONDUCTOR, SUPRASHIELD EXTRA-PREMIUM GRADE PVC JACKET FOR EXTENDED CABLE LIFE UL TYPE CM, AWM 2464 CSA CMG FT4 300 VOLT 34 CHOOSE XTRA GUARD 1FOR: Unsurpassed Flame and Moisture Resistance

More information

GameChanger Cable. Unshielded Twisted Pair Riser Rated - CMR PRYWB (legacy part no)

GameChanger Cable. Unshielded Twisted Pair Riser Rated - CMR PRYWB (legacy part no) GameChanger Cable Unshielded Twisted Pair Riser Rated - CMR 258310333 46224PRYWB (legacy part no) 1.0 Scope 1.1 This cable consists of 4 pair solid bare copper; color-coded high density polyethylene (HDPE)

More information

SBCA Industry Standards Subcommittee. Specification for 75 Ω Flexible RF Coaxial Drop Cable for Direct Broadcast Satellite (DBS) Installations

SBCA Industry Standards Subcommittee. Specification for 75 Ω Flexible RF Coaxial Drop Cable for Direct Broadcast Satellite (DBS) Installations SBCA Industry Standards Subcommittee Document: SBCA Series 6 Recommended Practices Date of Issue: Specification for 75 Ω Flexible RF Coaxial Drop Cable for Direct Broadcast Satellite (DBS) Installations

More information

Crestron Wire Product Guide

Crestron Wire Product Guide Crestron Wire Product Guide Cresnet Control Cable The Cresnet bus is the communications backbone for Crestron touchpanels, keypads, expansion modules, tuners, and more. Cresnet is a simple, yet flexible

More information

Industrial Automation & Control Cables

Industrial Automation & Control Cables 6 Industrial Automation & Control Cables Table Contents Introduction 2 Innovcable Data Solutions - Industrial Ethernet 3 Coaxial Cables 3 Innovcable Data Solutions - Industrial Twinax 4 Enerhose Cables

More information

ENGINEERING COMMITTEE Interface Practices Subcommittee AMERICAN NATIONAL STANDARD ANSI/SCTE

ENGINEERING COMMITTEE Interface Practices Subcommittee AMERICAN NATIONAL STANDARD ANSI/SCTE ENGINEERING COMMITTEE Interface Practices Subcommittee AMERICAN NATIONAL STANDARD ANSI/SCTE 177 2012 Specification for Braided 75 Ω, Mini-Series Quad Shield Coaxial Cable for CMTS and SDI cables NOTICE

More information

Detailed Specifications & Technical Data

Detailed Specifications & Technical Data For more Information please call 1-800-Belden1 General Description: PTZ (CCTV+Control+Power) Cable, Rated-CM, 1-RG59 20 AWG solid bare copper with foam polyolefin, 95% bare copper braid, 1-22 AWG stranded

More information

COMMON WORK RESULTS FOR INTEGRATED AUTOMATION DESIGN AND CONSTRUCTION STANDARD

COMMON WORK RESULTS FOR INTEGRATED AUTOMATION DESIGN AND CONSTRUCTION STANDARD PART 1: GENERAL 1.01 Purpose: A. This standard is intended to provide useful information to the Professional Service Provider (PSP) to establish a basis of design. The responsibility of the engineer is

More information

Communication, Control, and Industrial Cable

Communication, Control, and Industrial Cable Communication, Control, and Industrial Cable Specifications subject to change. For complete specifications and availability, visit www.alphawire.com. 291 Get control of demanding applications T he broad

More information

DataTwist 5 ScTP Cable

DataTwist 5 ScTP Cable 케이블콘 ( 주 ) 기술지원팀 :: 콘넥터문의 0707-3-770 케이블문의 0707-3-7702 N E T W O R K I N G C O P P E R 5.69 DataTwist 5 ScTP Cable TIA/EIA-568-TSB 36, Category 5 Nonbonded-Pair Cables 2 AWG Solid Bare Copper Conductors

More information

GO... with the Leader! Advanced Digital Cable is the manufacturing leader of cable for the traffic industry

GO... with the Leader! Advanced Digital Cable is the manufacturing leader of cable for the traffic industry GO... with the Leader! Advanced Digital Cable is the manufacturing leader of cable for the traffic industry ADC is a proud Sustaining Member of the IMSA organization and is the largest manufacturer in

More information

Distributed by: www.jameco.com 1-800-831-4242 The content and copyrights of the attached material are the property of its owner. For more information please call 1-800-Belden1 See Put-ups and Colors Description:

More information

Filled Solid ALPETH Cable

Filled Solid ALPETH Cable I. Exchange Cables Filled Solid ALPETH Cable REA/RUS PE-39 2.39.01 CONDUCTORS: Solid, annealed copper wires, in 2, 24, 22 and 19 AWG. INSULATION: Solid, high-density polyeylene or polypropylene in distinctive

More information

CUSTOM DESIGN COAXIAL CABLES BY SICAB

CUSTOM DESIGN COAXIAL CABLES BY SICAB CUSTOM DESIGN COAXIAL CABLES BY SICAB. COAX RG 58 C/U Application: Coaxial Cable 50 Ohm For indoor installation as well as in industrial areas in conduits and cable ducts, for transmission of high frequency

More information

Shielded Fire Alarm Cables

Shielded Fire Alarm Cables PLENUM Low-Smoke PVC JACKET UL TYPE FPLP/CMP/CL3P C(UL) CMP 300 VOLT Shielded Fire Alarm Cables Fire Alarm, Signal Monitor/Detection Audio or Control Circuits Description: Chart F, Page 41 Shielded Plenum

More information

CIR (Crush & Impact Resistant) VFD Power Cable

CIR (Crush & Impact Resistant) VFD Power Cable 37-2 CIRVFD CIR (Crush & Impact Resistant) VFD Power Cable Gexol Insulated Three Conductor 2kV Rated 90 C UL Listed as Type TC-ER Power Conductors (x3) Soft annealed flexible stranded tinned copper per

More information

GEXOL WORLD CLASS OIL & GAS CABLES

GEXOL WORLD CLASS OIL & GAS CABLES GEXOL WORLD CLASS OIL & GAS CABLES Severe Cold Durability Exceeds CSA Cold Bend / Cold Impact (-0 C/-35 C) Drilling Mud Resistant Flame Retardant Certified to IEC 9-3 (33-3A) and IEEE 580 Oil Resistant

More information

Distributed by: www.jameco.com 1-800-831-4242 The content and copyrights of the attached material are the property of its owner. For more information please call 1-800-Belden1 See Put-ups and Colors Description:

More information

Detailed Specifications & Technical Data

Detailed Specifications & Technical Data RFP Specification #17-11125-C, Exhibit 2 Programmable Light Poles for BART Plaza ENGLISH MEASUREMENT VERSION 1502SB Multi-Conductor - Multimedia Control Cable For more Information please call 1-800-Belden1

More information

Communication and Control Cable Pro Audio and Intercom Systems Unshielded

Communication and Control Cable Pro Audio and Intercom Systems Unshielded N E W G E N E R A T I O N C A B L E S 20.28 Counication and Control Cable Pro Audio and Interco Systes Unshielded Unshielded, or Multi-conductor CM FT1 Rated* Bare copper conductors, polypropylene (ulticonductor)

More information

Data sheet MC GC1200 pro22 Cat.7A S/FTP 4P LSHF-FR, class Dca s2 d2

Data sheet MC GC1200 pro22 Cat.7A S/FTP 4P LSHF-FR, class Dca s2 d2 Page 1/7 Illustrations Principle diagram See enlarged drawings at the end of document Product specification 10 GBit installation cable, simplex installation cable Cat.7A AWG 22 S/FTP with wires shielded

More information

To offer our customer the highest quality Broadband products at a competitive price with efficient Delivery and Inventory.

To offer our customer the highest quality Broadband products at a competitive price with efficient Delivery and Inventory. ALANTEK COMMUNICATIONS Founded in 1998 and headquartered in the USA, is a professional manufacturer of Broadband Coaxial Cables & Accessories. Its strength th in engineering and manufacturing is reflected

More information

14 AWG 2 AWG: 600 Volt

14 AWG 2 AWG: 600 Volt INDUSTRIAL AUTOMATION & PROCESS CONTROL CABLES 18.70 600V Type MC Metal Clad and Teck-Style Cables Overview Metal Clad Interlocked PVC Outer Jacket Teck-Style PVC Outer Jacket Introduction Polyester Wrap

More information

Canadian OSP Copper I-1. Table of Contents

Canadian OSP Copper I-1. Table of Contents Canadian OSP Copper Premises Copper Table of Contents CELFIL BJBB, BJAB, BJMB and BJTB................................. I-2 Canadian ALPETH BHBB, BHAB, BKMB and BKTB.................... I-4 SEALPAP BHBF,

More information

Analog Multi-Pair Snake Cable

Analog Multi-Pair Snake Cable B R I L L I A N C E B R O A D C A S T C A B L E S 19.16 High-Flex and Rated Cables Especially designed for the broadcast industry, Belden s full faily ulti-pair audio Snake cables feature options and construction

More information

SECTION WIRE AND CABLES. A. The CONTRACTOR shall provide wires and cable, complete and operable, in accordance with the Contract Documents.

SECTION WIRE AND CABLES. A. The CONTRACTOR shall provide wires and cable, complete and operable, in accordance with the Contract Documents. SECTION 26 05 19 PART 1 - GENERAL 1.1 THE REQUIREMENT A. The CONTRACTOR shall provide wires and cable, complete and operable, in accordance with the Contract Documents. 1.2 CONTRACTOR SUBMITTALS A. The

More information

New Product Bulletin. Belden Digital Audio Cable. Belden Brilliance AES/EBU

New Product Bulletin. Belden Digital Audio Cable. Belden Brilliance AES/EBU New Product Bulletin NP 267 Belden Digital Audio Cable Belden Brilliance AES/EBU Digital Audio Cable, Part No. 1353A, is a robust single-pair Cat 5e patch cord that utilizes Belden s exclusive Bonded-Pair

More information

MHR-2 Two Conductor Mini High Resolution S-Video Cable

MHR-2 Two Conductor Mini High Resolution S-Video Cable MHR- Two Conductor Mini High Resolution S-Video Cable Plenum rated Version Available MHR- Cable Two Color-Coded 6 AWG Stranded Coax Conductors Maintains signal quality and allows for easy identification

More information

Data sheet MC GC1200 pro22 Cat.7A S/FTP 2x4P LSHF-FR 1640 ft

Data sheet MC GC1200 pro22 Cat.7A S/FTP 2x4P LSHF-FR 1640 ft Page 1/7 Illustrations Principle diagram Product specification 10 GBit installation cable, duplex installation cable Cat.7A AWG 22 S/FTP with wires shielded in pairs 2x4 pairs (PiMF) pair shield: plastic

More information

LTE high-performance coaxial cables (RG replacement)

LTE high-performance coaxial cables (RG replacement) LTE high-performance coaxial cables (RG replacement) Center Conductor: See table below. Dielectric: LTE (extruded low-density PTFE) or low density / composite. Inner Shield: 875-892: None. 900-142: Flat

More information

* Peaks of 1.3mm MAX allowed only in a rate of 2% or less

* Peaks of 1.3mm MAX allowed only in a rate of 2% or less COAXIAL CABLE 50 OHM LOW LOSS 956163-3 A C 800275 Rev: D. 08 October 2014 Rev: C Maximum MHz db/100m MHz db/100m 100 16.3 1000 56.5 200 23.5 1500 70.2 500 38.2 1800 77.2 800 49.5 2000 81.5 Diameter of

More information

Cross-Connect and Distribution Frame Wire 5

Cross-Connect and Distribution Frame Wire 5 Datacom Cross-Connect and Distribution Frame Wire 5 With extended experience in the field of cross-connect wires, General Cable provides a variety of indoor and outdoor UL-listed cross-connect and distributing

More information

SMB Plug Connector Crimp/Solder Attachment for RG174, RG316, RG188, LMR-100, PE-B100, PE-C100, inch

SMB Plug Connector Crimp/Solder Attachment for RG174, RG316, RG188, LMR-100, PE-B100, PE-C100, inch SMB Plug Connector Crimp/Solder Attachment for RG174, RG316, RG188, LMR-100, PE-B100, PE-C100, 0100 inch RF Connectors Technical Data Sheet PE4046 Configuration SMB Plug Connector MIL-STD-348A 50 Ohms

More information

CCW. Continuously Corrugated Welded Cable. Armored Cable for Hazardous Locations

CCW. Continuously Corrugated Welded Cable. Armored Cable for Hazardous Locations CCW Continuously Corrugated Welded Cable Armored Cable for Hazardous Locations CCW Servicing Industrial and Specialty Applications This catalog contains in-depth information on the most comprehensive line

More information

Tru products are now under the Tru-Win brand from Winchester Interconnect.

Tru products are now under the Tru-Win brand from Winchester Interconnect. TRU MEIA Series Tru-Win MEIA offers the latest innovation in high power connector design. The MEIA interface provides equivalent kw power handling compared to similar EIA connector line sizes but provides

More information

RF Connectors Technical Data Sheet. Description Minimum Typical Maximum Units. Frequency Range DC 3 GHz VSWR 1.25:1 Operating Voltage (AC) 335 Vrms.

RF Connectors Technical Data Sheet. Description Minimum Typical Maximum Units. Frequency Range DC 3 GHz VSWR 1.25:1 Operating Voltage (AC) 335 Vrms. BNC Male Connector Crimp/Crimp Attachment for 100 inch, RG316, RG174, RG188, LMR-100, LMR- 100, LMR-100-FR, PE-C100, PE-B100 RF Connectors Technical Data Sheet PE45045 Configuration BNC Male Connector

More information

Part Number: 7953A Cat 6 600V DataTuff, (4 pr) 23 AW G Solid BC, PP/PVC/PVC, Foil Shld, CMR, CMX-Outdoor

Part Number: 7953A Cat 6 600V DataTuff, (4 pr) 23 AW G Solid BC, PP/PVC/PVC, Foil Shld, CMR, CMX-Outdoor Part Number: Cat 6 600V DataTuff, (4 pr) 23 AW G Solid BC, PP/PVC/PVC, Foil Shld, CMR, CMX-Outdoor Product Description Four Cat 6 23 AW G solid bare copper conductors, bonded pair polypropylene insulation,

More information

AEE. Canada. Australia

AEE. Canada. Australia DMARCA DE CONFORMIDA CORDS & ELECTRICAL UNIVERSAL POWER JUMPER CORD INTERNATIONAL AGENCIES APPROVED 302 POWER JUMPER CORD APPLICATIONS: To Connect Accessories and Peripherals to Computers and Electronic

More information

Information technology. Generic cabling systems, General requirements

Information technology. Generic cabling systems, General requirements KRAMER WELL CONNECTED WITH KRAMER BCLS-33OR-5 Al-Mylar Conductor CAT6A F/UTP LSZH Cable Drain Wire Kramer s BCLS-33OR is a high performance CAT6A F/UTP cable designed for IT, LAN and Ethernet installations.

More information

QN Male Connector Crimp/Solder Attachment for RG55, RG141, RG142, RG223, RG400

QN Male Connector Crimp/Solder Attachment for RG55, RG141, RG142, RG223, RG400 QN Male Connector Crimp/Solder Attachment for RG55, RG141, RG142, RG223, RG400 RF Connectors Technical Data Sheet PE44978 Configuration QN Male Connector 50 Ohms Straight Body Geometry Features Max Operating

More information

COPPER + LWL RAW CABLES

COPPER + LWL RAW CABLES COPPER + LWL RAW Twisted Pair Cables... 112 TV/SAT Cables... 116 Fiber Optic Raw Cables... 120 DIGITUS CAT 7 twisted pair installation cable 4x2xAWG23 S-FTP CAT 7 1000 MHz LSZH installation cable For installation

More information

C400-UMUM-100. Jumper Assembly Sample Label. Product Classification. General Specifications. Return Loss/VSWR

C400-UMUM-100. Jumper Assembly Sample Label. Product Classification. General Specifications. Return Loss/VSWR C400-UMUM-100 Product Classification Brand Product Series Product Type CNT Jumper with interface types UHF Male and UHF Male, 30.48 m CNT Braided cable assembly General Specifications Body Style, Connector

More information

UNIRAIL D RS485 and BUS cables

UNIRAIL D RS485 and BUS cables UNIRAIL D RS485 and BUS cables Type: 1x2x22 AWG/7 + 1x22 AWG/7 (1x2x0,35 + 1x0,35) Code: RW103A stranded tinned copper wire 22 AWG/7 (0,35 mm²) white blue POWER ELEMENTS: stranded bare copper wire 22 AWG/7

More information

Industrial Data. Conductor (stranding) Diameter Nom. DCR. Shielding Materials Nom. DCR. Color Code. (2)18 AWG TC Data Pair:

Industrial Data. Conductor (stranding) Diameter Nom. DCR. Shielding Materials Nom. DCR. Color Code. (2)18 AWG TC Data Pair: INDUSTRIAL AUTOMATION & PROCESS CONTROL CABLES 18.22 DeviceBus for VA DeviceNet DeviceNet Counications Rate Table Counications Rate 3082A Maxiu Distance 3082F 3082K 3083A 3084F 3084A/3085A 7895A 7896A

More information

TNC Male Right Angle Connector Crimp/ Solder Attachment for RG174, RG316, RG188, inch, PE-B100, PE-C100, LMR-100

TNC Male Right Angle Connector Crimp/ Solder Attachment for RG174, RG316, RG188, inch, PE-B100, PE-C100, LMR-100 TNC Male Right Angle Connector Crimp/ Solder Attachment for RG174, RG316, RG188, 0100 inch, PE-B100, PE-C100, LMR-100 RF Connectors Technical Data Sheet PE4455 Configuration TNC Male Connector 50 Ohms

More information

Microwave Coax. w w w. t e m p f l e x. c o m ( ) M i l f o r d R d. S o u t h G r a f t o n, M A

Microwave Coax. w w w. t e m p f l e x. c o m ( ) M i l f o r d R d. S o u t h G r a f t o n, M A Microwave Coax w w w. t e m p f l e x. c o m ( 5 0 8 ) 8 3 9-5 9 8 7 2 6 M i l f o r d R d. S o u t h G r a f t o n, M A 0 1 5 6 0 Microwave Coax Product Description Low Loss, Flexible Microwave products

More information

DOWNSTREAM POWER, CONTROL & INSTRUMENTATION CABLES

DOWNSTREAM POWER, CONTROL & INSTRUMENTATION CABLES DOWNSTREAM POWER, CONTROL & INSTRUMENTATION CABLES DOWNSTREAM FACILITY CABLES El Dorado, Arkansas Made in America CIR (Crush & Impact Resistant) CIR is a next-generation cable designed to replace older-technology

More information

MIL-C-17 Standard RF Coaxial Cable Low Loss & Ultra Low Loss RF Microwave Cable ANTENNA & TEST Cable up to 26.5 GHz

MIL-C-17 Standard RF Coaxial Cable Low Loss & Ultra Low Loss RF Microwave Cable ANTENNA & TEST Cable up to 26.5 GHz MIL-C-17 Standard RF Coaxial Cable Low Loss & Ultra Low Loss RF Microwave Cable ANTENNA & TEST Cable up to 26.5 GHz Low Loss Low Density PTFE Dielectric RF Microwave Coaxial Cable Silver Plated Copper

More information

SMA Male Connector Crimp/Solder Attachment for RG58, RG303, RG141, PE-C195, PE-P195, LMR-195, inch

SMA Male Connector Crimp/Solder Attachment for RG58, RG303, RG141, PE-C195, PE-P195, LMR-195, inch SMA Male Connector Crimp/Solder Attachment for RG58, RG303, RG141, PE-C195, PE-P195, LMR-195, 0195 inch RF Connectors Technical Data Sheet PE4215 Configuration SMA Male Connector MIL-STD-348A 50 Ohms Straight

More information

Data sheet MC GC1000 pro23 Cat.7 S/FTP 4P LSHF-FR 1640 ft

Data sheet MC GC1000 pro23 Cat.7 S/FTP 4P LSHF-FR 1640 ft Page 1/6 MC GC0 pro23 Cat.7 S/FTP 4P LSHF-FR 1640 ft 18427034141 Illustrations Principle diagram Product specification 10 GBit installation cable, simplex installation cable Cat.7 AWG 23 S/FTP with wires

More information

Contents. Category7 SSTP Solid Indoor Cable - Page 03

Contents. Category7 SSTP Solid Indoor Cable - Page 03 Product Catalog Contents Category7 SSTP Solid Indoor Cable - Page 03 Category6A UTP Solid Indoor Cable - Page 04 Category6A Keystone Jack - Page 05 Category6A Unshielded Patch Cord - Page 05 Category6

More information

For tough, seaworthy wire

For tough, seaworthy wire Dearborn Marine The Premier Choice for Marine Applications For tough, seaworthy wire and cable, Alpha Wire s Dearborn brand of products delivers performance in the most challenging environments for electrical

More information

Amphenol Cable. Features Allows for mass termination Up to 64 conductors

Amphenol Cable. Features Allows for mass termination Up to 64 conductors G80.7mm Economical Flat Ribbon 94V-0 A G80 X X XX X FLAT RIBBON CABLE.7mm Up to 64 conductors VARIATION CODE Blank: Standard PACAGING LENGTH NUMBER OF CONDUCTORS : 500 Feet 09: 9 Position : 400 Feet 4:

More information

Connection technology for wireless communication systems

Connection technology for wireless communication systems Connection technology for wireless communication systems Rosenberger Rosenberger, founded in 1958, is a family owned company and ranks today among the top global manufacturers of high-frequency coaxial

More information

Coaxial Cables Coax Serie. HF Steckverbinder für Mobilfunk-Anwendungen. in Bulk Rings or on Cable Drums

Coaxial Cables Coax Serie. HF Steckverbinder für Mobilfunk-Anwendungen. in Bulk Rings or on Cable Drums 4.3-10 Coax Serie Coaxial Cables HF Steckverbinder für Mobilfunk-Anwendungen in Bulk Rings or on Cable Drums Coaxial Cables In addition to the wide range of coaxial connectors, Telegärtner offers suitable

More information

Nexans Industrial Solutions PRODUCT CATALOG

Nexans Industrial Solutions PRODUCT CATALOG Nexans Industrial Solutions PRODUCT CATALOG i NEXANS BRINGS ENERGY TO LIFE COPPER CABLES Nexans brings energy to life through an extensive range of cables and cabling solutions that deliver increased performance

More information

Instrumentation Cables

Instrumentation Cables around a world of cables UL INSTRUMENTATION CABLES UL THHN CABLES UL THWN CABLES Instrumentation Cables INDEX Introduction Specialty Cables 300V & 00V Instrumentation Cable Types Certificates and Standards

More information

WIRE&CABLE FILS&CÂBLES S I N C E

WIRE&CABLE FILS&CÂBLES S I N C E WIRE&CABLE FILS&CÂBLES 50 CELEBRATING 50+ YEARS S I N C E 1 9 6 0 Dear Friend: Thank you for choosing Provo Ltd. As the leader in providing Canadian industry, coast-to-coast with a full line of electronic

More information

NETWORK CONNECTIVITY SYSTEMS

NETWORK CONNECTIVITY SYSTEMS NETWORK CONNECTIVITY SYSTEMS Installation Cable KS-STP Category 7 Installation Cable Certificates 10GBaseT FTP Category 6 Installation Cable UTP Category 6 Installation Cable UTP Category 5E Installation

More information

VFD CABLES 100% EMI CONTAINMENT FOR INDUSTRIAL APPLICATIONS

VFD CABLES 100% EMI CONTAINMENT FOR INDUSTRIAL APPLICATIONS VFD CABLES 100% EMI CONTAINMENT FOR INDUSTRIAL APPLICATIONS INDUSTRIAL VFD CABLES Index n Variable Frequency Drive (VFD) Power Cables Extra Flexible VFD Power Cable............... 2-3 Crush & Impact Resistant

More information

RG58 Coaxial Cable: 2) Approval:

RG58 Coaxial Cable: 2) Approval: RG58 Coaxial Cable: Center Conductor:---------- 19X0.18mm Solid Copper/20 AWG Solid Copper Dielectric:--------------------2.95±0.05mm Solid PE Braid Coverage:-------------95%X16X6X0.127±0.005mm Tinned

More information

SMA Male Connector Crimp/Solder Attachment for RG174, RG316, RG188 Gold Plated

SMA Male Connector Crimp/Solder Attachment for RG174, RG316, RG188 Gold Plated SMA Male Connector Crimp/Solder Attachment for RG174, RG316, RG188 Gold Plated RF Connectors Technical Data Sheet PE45145 Configuration SMA Male Connector 50 Ohms Straight Body Geometry RG174, RG316, RG188

More information

C240-NFSM-3M. Jumper Assembly Sample Label. Product Classification. General Specifications. Return Loss/VSWR

C240-NFSM-3M. Jumper Assembly Sample Label. Product Classification. General Specifications. Return Loss/VSWR C240-NFSM-3M Product Classification Brand Product Series Product Type CNT Jumper with interface types N Female and SMA Male, 3m CNT Braided cable assembly General Specifications Body Style, Connector A

More information

TwenCombi Cat-5E FTP(3x) - Coax 9 - EIBA - tube PE 5 mm

TwenCombi Cat-5E FTP(3x) - Coax 9 - EIBA - tube PE 5 mm name: TKF article number: 10305 description Nr.: POE- PS- 10305 PT F F F 800 B C 1 2 3 4 5 6 7 Assembly: 1. Primary tube 5 mm 2. CAT 5 E FTP cable 3. CAT 5 E FTP cable 4. Bus cable 5. Coax 9 cable 6. Separation

More information

N Male Connector Clamp/Solder Attachment for PE-C500, LMR-500

N Male Connector Clamp/Solder Attachment for PE-C500, LMR-500 N Male Connector Clamp/Solder Attachment for PE-C500, LMR-500 RF Connectors Technical Data Sheet PE44046 Configuration N Male Connector MIL-STD-348A 50 Ohms Features Gold Plated Brass Contact Applications

More information

ÖLFLEX FORTIS 55 Highly Flexible and Extremely Oil-Resistant Tray Cable; -40 C Flexible/-55 C Stationary

ÖLFLEX FORTIS 55 Highly Flexible and Extremely Oil-Resistant Tray Cable; -40 C Flexible/-55 C Stationary TRAY-RATED CABLE Quick Select Chart 48 TC 600/TC 600 S 50 Flexible Tray Cable with TC-ER for Easier Installations; Unshielded & Shielded TRAY II/TRAY II CY 52 Extremely Oil-Resistant & Flexible Tray Cable

More information

RP TNC Male Connector Crimp/Solder Attachment for PE-C240, RG8X, inch, LMR-240, LMR-240-DB, LMR-240-UF, B7808A

RP TNC Male Connector Crimp/Solder Attachment for PE-C240, RG8X, inch, LMR-240, LMR-240-DB, LMR-240-UF, B7808A RP TNC Male Connector Crimp/Solder Attachment for PE-C240, RG8X, 0240 inch, LMR-240, LMR-240-DB, LMR-240-UF, B7808A RF Connectors Technical Data Sheet PE44670 Configuration TNC Male Reverse Polarity Connector

More information

N Male Connector Crimp/Solder Attachment For RG58

N Male Connector Crimp/Solder Attachment For RG58 N Male Connector Crimp/Solder Attachment For RG58 RF Connectors Technical Data Sheet PE4329 Configuration N Male Connector 50 Ohms Straight Body Geometry RG58 Interface Type Crimp/Solder Attachment Electrical

More information

Wire and Cable. 99 Wire Dual Wall 120ºC rated, Modified Polyester Low fire hazard wire and cable. Features & Benefits

Wire and Cable. 99 Wire Dual Wall 120ºC rated, Modified Polyester Low fire hazard wire and cable.   Features & Benefits Dual Wall 20ºC rated, Modified Polyester 99 wire has a dual wall construction of radiation crosslinked modified polyester. This combines excellent mechanical performance and chemical resistance with a

More information

SMA Male QD Connector Crimp/Solder Attachment For RG142, RG223, RG400, RG55

SMA Male QD Connector Crimp/Solder Attachment For RG142, RG223, RG400, RG55 SMA Male QD Connector Crimp/Solder Attachment For RG142, RG223, RG400, RG55 RF Connectors Technical Data Sheet Configuration SMA Male Connector 50 Ohms Straight Body Geometry RG142, RG223, RG400, RG55

More information

EXCELLENT ELECTRICAL PERFORMANCES

EXCELLENT ELECTRICAL PERFORMANCES 50OHMS CORRUGATED COPPER TUBE COAXIAL CABLE PRODUCT INTRODUCTION 2 Hansen's manufacturing of wide-scope 50ohms corrugated copper coaxial Cable is the fruitful result of the engineers' diligent research

More information

C400-TMTM-30-X. Jumper Assembly Sample Label. Product Classification. General Specifications. Electrical Specifications

C400-TMTM-30-X. Jumper Assembly Sample Label. Product Classification. General Specifications. Electrical Specifications C400-TMTM-30-X Product Classification Brand Product Series Product Type CNT-400-FR CNT Jumper with interface types TNC Male and TNC Male, 9.14 m CNT CNT-400 Braided cable assembly General Specifications

More information

COAXIAL CABLE and FITTINGS SUMMARY RF CABLE ASSEMBLIES

COAXIAL CABLE and FITTINGS SUMMARY RF CABLE ASSEMBLIES SUMMARY RF CABLE ASSEMBLIES Custom Cable Assemblies Standard Cable Sets CABLE FITTINGS 7/8" Flexible Foam Dielectric, 50 Ohm Hoisting Stocking Grips 1/2" Flexible Foam Dielectric, 50 Ohm Bird-Proof Stainless

More information

Caledonian. Profibus L2 Indoor BUS CABLE. Application: Construction:

Caledonian. Profibus L2 Indoor BUS CABLE. Application: Construction: Caledonian www.caledonian-cables.co.uk www.caledonian-cables.net Profibus L2 Indoor Application: This system cable is used to interconnect L2-BUS components. This cable is an economical solution for the

More information

MULTIMEDIA CABLE H6091ZHB

MULTIMEDIA CABLE H6091ZHB CAVEL News MULTIMEDIA CABLE H6091ZHB MULTIMEDIA CABLE H6091ZHB Multimedia is a must in the modern way of life. Growing communication needs in any environment whether at home or the office the connection

More information

CATALOG OF PRODUCTS. Your Best Supplier of Electrical Cables

CATALOG OF PRODUCTS. Your Best Supplier of Electrical Cables CATALOG OF PRODUCTS Isolated Copper Wire THHN/MTW/THWN-2 600V, single conductor having flame-retardant and heat-resistant thermoplastic insulation with a jacket of extruded nylon or equivalent material.

More information

Microphone and Musical Instrument Cable Overview

Microphone and Musical Instrument Cable Overview B R I L L I A N C E B R O A D C A S T C A B L E S 19.3 Microphone and Musical Instruent Cable Overview Flexible Microphone Cables Belden icrophone cable is used for connecting low level icrophones or usical

More information

TNC Male Connector Crimp/Solder Attachment for RG214, RG9, RG225, RG393

TNC Male Connector Crimp/Solder Attachment for RG214, RG9, RG225, RG393 TNC Male Connector Crimp/Solder Attachment for RG214, RG9, RG225, RG393 RF Connectors Technical Data Sheet PE4447 Configuration TNC Male Connector MIL-STD-348A 50 Ohms Features Max Operating Frequency

More information

EZ-200-NMH-D ok by tech Svcs

EZ-200-NMH-D ok by tech Svcs EZ-200-NMH-D ok by tech Svcs EZ-200-NMH-D ok by tech Svcs LMR LMR-200 600 TIMES MICROWAVE SYSTEMS LMR -200 Flexible Low Loss Communications Coax Ideal for Jumper Assemblies in Wireless Communications Systems

More information

Composite Data, Audio, Video, Security and Control Cables Banana Peel Jacketless Cables Category 5e

Composite Data, Audio, Video, Security and Control Cables Banana Peel Jacketless Cables Category 5e R E S I D E N T I A L C A B L E S 21.4 Coposite Data, Audio, Video, Security and Control Cables Banana Peel less Cables Category 5e Coposite (2) Cat 5e 4-Bonded-Pair UTP 24 AWG (2) Series 6 Coax with Duobond

More information

WIRE & CABLE. 99 Wire Low fire hazard wire and cable

WIRE & CABLE. 99 Wire Low fire hazard wire and cable Applications 99 wire has a dual wall construction of radiation cross-linked modified polyester. This combines excellent mechanical performance and chemical resistance with a range of enhanced fire hazard

More information

Field Instrument Cable. Electrical Noise

Field Instrument Cable. Electrical Noise Field Instrument Cable Electrical Noise 1 Electrical Noise Instrument Cables are Susceptible to 4 Types of Noise: Static Magnetic Cross-Talk Common Mode 2 Static Noise Static Noise is caused by an electric

More information

EC 200 CHARACTERISTICS D A T A S H E E T. Kabelwerk EUPEN AG cable. M e c h a n i c a l c h a r a c t e r i s t i c s

EC 200 CHARACTERISTICS D A T A S H E E T. Kabelwerk EUPEN AG cable. M e c h a n i c a l c h a r a c t e r i s t i c s EC 200 EC200 - Rev. 3-23.06.11 Characteristic impedance 50 ± 2 Material copper wire Nominal capacity (pf/m) 80.5 Construction - Relative propagation velocity (%) 83 Diameter (mm) 1.05 Inductance (µh/m)

More information

Coated Dead-end NOMENCLATURE GENERAL RECOMMENDATIONS

Coated Dead-end NOMENCLATURE GENERAL RECOMMENDATIONS NOMENCLATURE Crossover Marks: Indicate starting point for application. Gritted and Neoprene Dipped Legs: Grit is permanently embedded in a coating of neoprene. GENERAL RECOMMENDATIONS Coated Dead-ends:

More information

DETAIL SPECIFICATION SHEET CABLE, SPECIAL PURPOSE, ELECTRICAL, TWELVE INDIVIDUALLY SHIELDED PAIRS 22 (7 X 30) AWG

DETAIL SPECIFICATION SHEET CABLE, SPECIAL PURPOSE, ELECTRICAL, TWELVE INDIVIDUALLY SHIELDED PAIRS 22 (7 X 30) AWG INCH-POUND MIL-DTL-49285/22B 27 March 2018 SUPERSEDING MIL DTL 49285/22A 1 March 2010 DETAIL SPECIFICATION SHEET CABLE, SPECIAL PURPOSE, ELECTRICAL, TWELVE INDIVIDUALLY SHIELDED PAIRS 22 (7 X 30) AWG Inactive

More information

n 100% EMI Emission Containment n Designed for Longer Service Life n Highly Flexible

n 100% EMI Emission Containment n Designed for Longer Service Life n Highly Flexible n 0% EMI Emission Containment n Designed for Longer Service Life n Highly Flexible Nexans AmerCable VFD CABLES CABLES Index VFD Cables Standard VFD Power Cable... 2-3 Low Smoke Halogen-Free VFD Power Cable...

More information

Cable Attachment Method (Shield/Contact) Size Length, in [mm] 0.98 [24.89] Width/Dia., in [mm] [9.53]. Weight, lbs [g] 0.02 [9.07] 3.

Cable Attachment Method (Shield/Contact) Size Length, in [mm] 0.98 [24.89] Width/Dia., in [mm] [9.53]. Weight, lbs [g] 0.02 [9.07] 3. Configuration Interface Type Cable Attachment Method (Shield/Contact) Body Style PE-SR402AL,PE-SR402FL,RG402 Clamp/Solder Straight Electrical Specifications Impedance, Ohms 50 Mechanical Specifications

More information

7/16 DIN Male Right Angle Connector Clamp/Solder Attachment for RG213, RG214, RG8, RG9, RG225, RG393, RG215

7/16 DIN Male Right Angle Connector Clamp/Solder Attachment for RG213, RG214, RG8, RG9, RG225, RG393, RG215 7/16 DIN Male Right Angle Connector Clamp/Solder Attachment RF Connectors Technical Data Sheet PE44280 Configuration 7/16 DIN Male Connector MIL-C-39012 50 Ohms Right Angle Body Geometry Features Silver

More information

ADVANCED FLAT CABLE SOLUTIONS

ADVANCED FLAT CABLE SOLUTIONS ADVANCED FLAT CABLE SOLUTIONS ONTENTS Contents F Flat Ribbon Cable Overview 03 Microzip Summary Sheet 04 Microzip TPO Solid & Stranded 0.025 inch (0.635 mm) 05 Microzip PVC Solid & Stranded 0.025 inch

More information

SPEC 55 Wire and Cable High-performance wire and cable insulation system for 65 C to 200 C

SPEC 55 Wire and Cable High-performance wire and cable insulation system for 65 C to 200 C SPEC 55 Wire and Cable High-performance wire and cable insulation system for 65 C to 200 C Applications Hookup and signal wire and cable used in aircraft, avionics, military electronics, satellites, helicopters,

More information

Over 35 Years of Service. Our Commitment. Dedicated to Our Customers. Product Expertise and Specialized Services. Strategic Partnerships

Over 35 Years of Service. Our Commitment. Dedicated to Our Customers. Product Expertise and Specialized Services. Strategic Partnerships Tray Cable Our Commitment Our commitment to our customers is simple - we deliver even when others can t. As one of Canada s largest wire, cable and data communication distributors for over 35 years, Texcan

More information

LV AIRGUARD. P r o ble m. ife? No S. a proven, rugged product for harsh environments

LV AIRGUARD. P r o ble m. ife? No S. a proven, rugged product for harsh environments ife? No S n K P r o ble m! No? aw a proven, rugged product for harsh environments No LV AIRGUARD LV AIRGUARD Low Voltage Cables for Harsh Environments FEATURES - No Knife? No Saw? No Problem! installation

More information