1 THE CENTER FOR RESEARCH AND EDUCATION IN ADVANCED TRANSPORTATION ENGINEERING SYSTEMS (CREATEs) ISSUED FOR BID - CONTRACT MULLICA HILL ROAD GLASSBORO, NEW JERSEY ALL DIMENSIONS MUST BE VERIFIED PREPARED FOR: MANTUA TOWNSHIP: BLOCK 261, LOTS 8, 9, & 9.01 HARRISON TOWNSHIP: BLOCK 1, LOT 4 MARCH 2, 2016 PROJECT LOCATION PROJECT LOCATION PROJECT LOCATION Scale: NTS Scale: NTS Scale: 1" = 2000' DRAWING SHEET LIST DWG NO. SHEET TITLE DATE GENERAL CS0001 CS0002 COVER SHEET GENERAL NOTES AND LEGEND ARCHITECTURAL A-0 A-1 A-2 A-3 A-4 CODE SUMMARY FLOOR PLAN ELEVATIONS BUILDING SECTIONS AND DETAILS WALL SECTIONS LAST REVISED USGS MAP LOCATION MAP WEST CAMPUS TAX MAP NEW JERSEY ONE CALL CS8502 COVER SHEET ELECTRICAL E-0 E-1 E-2 ELECTRICAL SITE PLAN ELECTRICAL FLOOR PLAN, SCHEDULES, AND DETAILS ELECTRICAL DETAILS AS-NOTED MECHANICAL & PLUMBING CALL BEFORE YOU DIG MP-1 MECHANICAL & PLUMBING - FLOOR PLAN, SCHEDULES & DETAILS STRUCTURAL CONTRACTOR SHALL BE RESPONSIBLE TO COMPLY WITH THE REQUIREMENTS OF THE NEW JERSEY ONE-CALL DAMAGE PREVENTION SYSTEM AS STATED IN THE "UNDERGROUND FACILITY PROTECTION ACT". S1001 STRUCTURAL NOTES, FOUNDATION PLAN & DETAILS REVISIONS AND SUBMISSIONS NO. SANITARY SEWER DETAILS UTILITY DETAILS SOIL EROSION AND SEDIMENT CONTROL PLAN SOIL EROSION AND SEDIMENT CONTROL PLAN SOIL EROSION AND SEDIMENT CONTROL NOTES SOIL EROSION AND SEDIMENT CONTROL DETAILS DATE 515 Grove Street, Suite 1B Haddon Heights, NJ T F EXISTING CONDITIONS PLAN DEMOLITION PLAN SITE PLAN GRADING AND DRAINAGE PLAN UTILITY PLAN UTILITY PLAN STORM SEWER PROFILES UTILITY PROFILES SITE DETAILS SITE DETAILS SITE DETAILS SITE DETAILS STORM SEWER DETAILS PREPARED : CS0201 CS0501 CS1001 CS1501 CS1701 CS1702 CS4001 CS4501 CS6001 CS6002 CS6003 CS6004 CS6021 CS6051 CS6061 CS8001 CS8002 CS8501 ISSUED FOR BID CIVIL/SITE CS0001

2 SELECT DEMOLITION NOTES SURVEY NOTES: C-1. D-1. ALL DEMOLITION WORK SHALL BE PERFORMED IN ACCORDANCE WITH NFPA 241 AND OSHA STANDARDS. 1. A FIELD SURVEY OF THE SITE WAS PERFORMED PENNONI ASSOCIATES IN OCTOBER OF D-2. ALL HOLES AND OPEN AREAS REMAINING AFTER DEMOLITION SHALL BE BACKFILLED TO MATCH EXISTING GRADE IN ACCORDANCE WITH NOTE G-23 HEREON AND APPLICABLE SPECIFICATIONS. 2. LOCATIONS OF ON AND OFF SITE UTILITIES AS SHOWN ARE APPROXIMATE AND MAY OR MAY NOT BE COMPLETE. THE NATURE AND EXACT LOCATION OF EXISTING UTILITIES SHOULD BE VERIFIED PRIOR TO INITIATING ANY ACTIVITY THAT MAY AFFECT THEIR USE OR LOCATION. D-4. D-5. C-3. ALL WATER MAIN DESIGN AND CONSTRUCTION SHALL BE IN ACCORDANCE WITH STANDARDS SET FORTH NEW JERSEY AMERICAN WATER. C-4. A MINIMUM OF FOUR (4) FEET OF COVER SHALL BE MAINTAINED ON WATER MAINS UNLESS OTHERWISE NOTED. WATER PIPING LESS THAN OR EQUAL TO TWO(2) INCHES IN DIAMETER SHALL BE TYPE "K" SOFT TEMPER COPPER TUBING AND COMPRESSION FITTINGS. C-8. CONTRACTOR SHALL EXCAVATE ONLY ENOUGH TRENCH TO INSTALL NEW UTILITY AND BACKFILL THE END OF EACH WORK DAY. OPEN TRENCH SHALL NOT BE PERMITTED AT ANY TIME CONTRACTOR IS NOT ACTIVELY WORKING ON PORTION OF UTILITY REQUIRING OPEN EXCAVATION. C-9. WATER MAIN APPURTENANCES, SUCH AS BUT NOT LIMITED TO: FITTINGS AND VALVES SHALL BE BLOCKED WITH CONCRETE AS DETAILED HEREIN. C-10. BEFORE STARTING WORK, CONTRACTOR SHALL FURNISH A CONSTRUCTION SCHEDULE TO THE CONSTRUCTION MANAGER, APPLICABLE UTILITY COMPANIES, INTERESTED PARTIES AND THE OWNER PRIOR TO CONSTRUCTION. SCHEDULE SHALL DETAIL ALL ITEMS ASSOCIATED WITH CARRYING OUT CONTRACT, ON A DAILY BASIS. CONSTRUCTION SHALL BE SEQUENCED SUCH THAT NOT MORE THAN ONE HYDRANT IS OUT OF SERVICE AT ANY GIVEN TIME. CONTRACTOR SHALL COORDINATE DIRECTLY WITH FIRE MARSHALL WITH REGARD TO HYDRANT SERVICE INTERRUPTIONS NOT LESS THAN 3 DAYS PRIOR TO INTERRUPTION. CONTRACTOR SHALL COORDINATE DIRECTLY WITH INDIVIDUAL HOMEOWNERS WITH REGARD TO SERVICE INTERRUPTIONS. CONTRACTOR SHALL CLEARLY DOCUMENT INTERRUPTION IN SERVICE TO HOMEOWNER NOT LESS THAN 5 DAYS PRIOR TO INTERRUPTION; SAID NOTIFICATION SHALL INCLUDE WRITTEN INSTRUCTION TO HOMEOWNER WITH REGARD TO RESTORING SERVICE, FLUSHING TAPS, ETC. C-11. EXISTING MAINS TO BE ABANDONED IN PLACE SHALL BE CAPPED AND FILLED WITH AN APPROVED CLSM. C-12. CONTRACTOR SHALL CONSTRUCT NEW 2-INCH WATER SERVICE LATERAL FROM THE EXISTING MAIN TO THE NEW FACILITY AS SHOWN ON THE PLANS. PRIOR TO CONSTRUCTION, CONTRACTOR SHALL CONTACT VITO SQUADRITO FROM NEW JERSEY AMERICAN WATER AT (856) TO COORDINATE THE CONSTRUCTION OF THE NEW CORPORATION STOP AT THE EXISTING MAIN, THE NEW CURB STOP, THE NEW METER PIT AND THE NEW DOMESTIC WATER METER. ALL EXISTING CATCH BASINS AND MANHOLES SHALL BE FIELD LOCATED PRIOR TO WORK AND THE ENGINEER SHALL BE NOTIFIED OF ANY DISCREPANCIES PERTAINING TO LOCATIONS SHOWN ON THE CONTRACT DRAWINGS. FIELD VERIFY GRADE CONDITION AND ELEVATIONS AFTER DEBRIS AND SOILS HAVE BEEN REMOVED. D-7. ALL UTILITIES SHALL BE REMOVED TO A MINIMUM OF FOUR (4) FT BELOW EXISTING GROUND SURFACE. DEMOLISH FIRE HYDRANT THRUST BLOCKS IF ENCOUNTERED. D-8. ELECTRICAL UTILITIES SHALL BE DISCONNECTED PRIOR TO BEGINNING ANY DEMOLITION WORK. DEMOLITION SHALL INCLUDE THE REMOVAL OF BURIED AND EXPOSED CONDUIT IN THE AREA DESIGNATED FOR DEMOLITION, SEALING ENDS OF ALL BURIED CONDUIT ABANDONED IN PLACE AND REMOVING ALL POWER AND CONTROL WIRING BETWEEN THE DEMOLISHED FACILITY AND THE TERMINAL JUNCTION BOX, CIRCUIT BREAKER, OR METER CONTROL CENTER SUPPLYING POWER TO THE FACILITY. C-6. PIPE BEDDING REQUIREMENTS SPECIFIED HEREIN ARE TO BE CONSIDERED AS MINIMUMS FOR RELATIVELY DRY, STABLE EARTH CONDITIONS. ADDITIONAL BEDDING SHALL BE REQUIRED FOR ROCK TRENCHES AND WET AREAS. CONTRACTOR SHALL HAVE THE RESPONSIBILITY TO PROVIDE SUCH ADDITIONAL BEDDING AS MAY BE REQUIRED TO PROPERLY CONSTRUCT THE WORK. D THE PORTION OF SITE LOCATED IN MANTUA TOWNSHIP IS CURRENTLY ZONED FLX/PC, FLEX SPACE W/ PLANNED COMMERCIAL OVERLAY, ACCORDING TO THE CURRENTLY AMENDED TOWNSHIP OF MANTUA ONLINE ZONING MAP. THE PORTION OF SITE LOCATED IN HARRISON TOWNSHIP IS CURRENTLY ZONED INS, INSTITUTIONAL, ACCORDING TO THE CURRENTLY AMENDED TOWNSHIP OF HARRISON ONLINE ZONING MAP. THE REMOVAL OF EXISTING BOLLARDS, GUIDE RAIL POSTS & FOOTINGS SHALL INCLUDE THE PIPE/ POST AND CONCRETE FOOTING IN ITS ENTIRETY. D-6. C-5. ALL WATER MAINS SHALL BE CONSTRUCTED A MINIMUM OF 15 FEET FROM THE FOUNDATION OF A BUILDING UNLESS OTHERWISE NOTED. C-7. BACKFILL IN THE TRENCHES SHALL BE COMPACTED TO THE DENSITY OF 95% OF THEORETICAL MAXIMUM DRY DENSITY (ASTM D698). BACKFILL MATERIAL SHALL BE FREE FROM ROOTS, STUMPS, OR OTHER FOREIGN DEBRIS AND SHALL BE PLACED IN LIFTS NOT TO EXCEED 6 INCHES IN COMPACTED FILL THICKNESS. A REPORT FROM A GEOTECHNICAL ENGINEER MAY BE REQUIRED THE ENGINEER. CORRECTION OF ANY TRENCH SETTLEMENT WITHIN A YEAR FROM THE DATE OF APPROVAL WILL BE THE RESPONSIBILITY OF THE CONTRACTOR. WHERE A PIPE BEING REMOVED IS CONNECTED TO AN EXISTING STRUCTURE, EITHER REMOVE THE PIPE AND FILL THE WALL OPENING WITH CONCRETE, OR CUT THE PIPE WITHOUT PERCUSSION NOT MORE THAN 6" FROM THE OUTSIDE FACE OF THE STRUCTURE AND FILL THE REMAINING LENGTH OF PIPE WITH CONCRETE. 4. EXISTING UTILITIES: A. THE LOCATION OF THE EXISTING UNDERGROUND UTILITIES SHOWN ON THIS PLAN HAVE BEEN TAKEN FROM SURFACE OBSERVATION OF THE SITE AT THE TIME OF THE SURVEY. B. COMPLETENESS OR ACCURACY OF LOCATION AND DEPTH UNDERGROUND UTILITIES AND STRUCTURES IS NOT GUARANTEED. OF C. THE CONTRACTOR SHALL VERIFY LOCATIONS AND DEPTHS OF ALL UNDERGROUND UTILITIES AND STRUCTURES BEFORE THE START OF WORK. 5. VERTICAL DATUM BASED NORTH AMERICAN VERTICAL DATUM 88 (NAVD 88) GPS OBSERVATION. 6. PROPERTY AND RIGHT-OF-WAY LINES SHOWN ARE GRAPHICAL PLOTTING ONLY BASED ON TAX MAPS OF RECORD. PROPERTY AND RIGHT-OF-WAY LINES ARE FOR REFERENCE PURPOSES ONLY. ALL MATERIAL BROUGHT ON SITE SHALL BE CLEAN FILL, SAMPLED, AND ANALYZED WITH STANDARD NJDEP QUALITY ASSURANCE STANDARDS AND PRACTICES AT A MINIMUM, AS SPECIFIED IN N.J.A.C. 7:26E, TO FULLY CHARACTERIZE THE CONTAMINANTS IN THE LATEST SOIL CLEANUP CRITERIA (SCC). THE CONTRACTOR SHALL SUBMIT TO THE OWNER WRITTEN DOCUMENTATION FROM A LABORATORY CERTIFIED IN NEW JERSEY ENVIRONMENTAL LABORATORY CERTIFICATION PROGRAM (ELCP) AND IN ACCORDANCE WITH N.J.A.C. 7:18 PRIOR TO PLACEMENT OF THE MATERIAL ON SITE. THE MATERIAL MUST NOT CONTAIN CONTAMINANTS ABOVE THE MOST RESTRICTIVE DIRECT CONTACT OR IMPACT TO GROUNDWATER (IGW) SCC. PHONE: (856) GAS: SOUTH JERSEY GAS 142 S. MAIN STREET GLASSBORO, NJ ATTN: JOHN PIRRI WATER : NJAW 204 CARRIAGE LANE DELRAN, NJ ATTN: PHONE: (856) X.6336 PHONE: (856) TELEPHONE: VERIZON COMMUNICATIONS 10 TANSBORO ROAD BERLIN, NJ ATTN: SEBASTIAN ALADIPO PHONE: TELEPHONE: AT & T (BURIED FIBER OPTIC CABLE) 50 PATRICIA DRIVE FLANDERS, NJ ATTN: LOU MARELLO PHONE: (973) CABLE TV: COMCAST CABLE COMPANY (CONSTRUCTION DEPT.) 250 HADDONFIELD-BERLIN ROAD CHERRY HILL, NJ ATTN: ALEX PEIDL PHONE: (856) REGIONAL SEWER: GLOUCESTER COUNTY UTILITY AUTHORITY 2 PARADISE ROAD WEST DEPTFORD, NJ ATTN: TED BAMFORD/TOM SHOULDER PHONE: (856) STATE R.O.W.: NJ STATE DEPARTMENT OF TRANSPORTATION PLANNING DIVISION P.O. BOX 600 TRENTON, NJ ATTN: PHONE: D-10. CONTRACTOR SHALL NOTIFY OWNER AND THE ENGINEER 72 HRS. PRIOR TO INITIATING UTILITY ABANDONMENT. D-11. ALL ACTIVE CONSTRUCTION SITES AND LOCATIONS SHALL BE PROVIDED WITH NON-COMBUSTIBLE REFUSE CONTAINER(S) IN SUCH NUMBERS AS SHALL BE NECESSARY TO CONTAIN ALL COMBUSTIBLE REFUSE GENERATED THE CONSTRUCTION ACTIVITIES. CONTROLLED INSPECTIONS: D-12. ALL COMBUSTIBLE REFUSE, RUBBISH AND DEBRIS SHALL BE COLLECTED UP AND DEPOSITED IN THE CONTAINER(S) ON A DAILY BASIS. REFUSE CONTAINER(S) SHALL BE LOCATED A MINIMUM OF 20 FEET AWAY FROM ANY BUILDING, STRUCTURE, LOT LINE OR COMBUSTIBLE MATERIAL STORAGE LOCATION. D-13. WHILE CONSTRUCTION ACTIVITIES ARE IN PROGRESS, AT LEAST FOUR(4) PORTABLE FIRE EXTINGUISHERS HAVING A RATING OF AT LEAST 10-A, 60-BC SHALL BE PROVIDED, AND SHALL BE MAINTAINED IN A LOCATION APPROVED THE FIRE OFFICIAL. PERSONNEL NORMALLY ON THE CONSTRUCTION SITE SHALL BE INSTRUCTED IN THE USE OF THE FIRE EXTINGUISHERS PROVIDED. UTILITY NOTE D-14. CONTRACTOR IS RESPONSIBLE FOR MAINTAINING AND PROTECTING EXISTING IRRIGATION SYSTEM IF ENCOUNTERED. ANY DAMAGE CAUSED TO SAID SYSTEM SHALL BE REPAIRED THE CONTRACTOR AT THEIR SOLE EXPENSE TO THE SATISFACTION OF THE OWNER AND ENGINEER. D-15. CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATING THE DISCONNECTION AND/OR REMOVAL OF ANY SERVICE UTILITIES ATTACHED/CONNECTED/RECIEVING/SUPPLYING, ETC. TO ANY BUILDING AND/OR STRUCTURE NOTED HEREIN TO BE DEMOLISHED. CONTRACTOR SHALL OBTAIN ANY NECESSARY PERMITS OR APPROVALS ASSOCIATED WITH SAME. D-3. ELECTRIC: ATLANTIC CITY ELECTRIC 428 ELLIS STREET GLASSBORO, NJ ATTN: GUENTER SCHMIDT C-2. SEWERS AND WATER MAINS GENERALLY SHALL BE SEPARATED, A DISTANCE OF AT LEAST 10FT HORIZONTALLY. IF SUCH LATERAL SEPARATION IS NOT POSSIBLE, THE PIPES SHALL BE IN SEPARATE TRENCHES WITH THE SEWER AT LEAST 18 INCHES BELOW THE BOTTOM OF THE WATER MAIN: OR SUCH OTHER SEPARATION AS APPROVED N.J.A.W. SHALL BE MADE. IN GENERAL, THE VERTICAL SEPARATION AT A CROSSING OF SEWER AND WATER LINE SHALL SHALL BE AT LEAST 18 INCHES. WHERE THIS IS NOT POSSIBLE, THE SEWER SHALL BE CONSTRUCTED OF CAST IRON PIPE USING MECHANICAL OR SLIP-ON JOINTS, OR HOT POURED LEAD JOINTS FOR A DISTANCE OF AT LEAST 10FT ON EITHER SIDE OF THE CROSSING OR OTHER SUITABLE PROTECTION SHALL BE PROVIDED. PUBLIC UTILITIES ALL DIMENSIONS MUST BE VERIFIED ALL WATER MAINS GREATER THAN 2-INCHES IN DIAMETER SHALL BE CEMENT LINED DUCTILE IRON PIPE CONFORMING TO A.N.S.I. A (AWWA C151) CLASS 52, PUSH-ON JOINTS WILL BE PERMITTED ON RUNS. FITTINGS SHALL BE MECHANICAL JOINT BLOCKED WITH CONCRETE. ANY WATER MAIN CONSTRUCTED WITHIN 15 FEET OF A BUILDING SHALL UTILIZE MEGA-LUG JOINTS. CIVIL NOTES: HIGH-VOLTAGE PROXIMITY ACT D-16. PRIOR TO REMOVAL OF EXISTING FULL-DEPTH ASPHALTIC AND/OR CONCRETE PAVEMENT, CONTRACTOR SHALL SAWCUT TO FULL DEPTH TO PROVIDE A CLEAN STRAIGHT EDGE. CONCRETE SIDEWALK AND/OR CURB SHALL BE REMOVED TO THE NEAREST CONTROL JOINT. LEGEND EXISTING LEGEND PROPOSED EXISTING LEGEND PROPOSED EXISTING PROPOSED ELECTRICAL HANDHOLE SEPTIC TANK ELECTRICAL METER PROPERTY LINE UTILITY POLE ELECTRICAL MANHOLE SETBACK LINE ELECTRICAL PANEL BOX BUSH RIGHT-OF-WAY LINE ROADWAY CENTERLINE ELECTRICAL PEDESTAL FENCE ELECTRICAL STUB OUT CONIFEROUS TREE ELECTRICAL STUB OUT DECIDUOUS TREE SIDEWALK MONITORING WELL CONCRETE STUMP SPOT ELEVATION IRRIGATION HEAD FIRE HYDRANT LIGHT BOLLARD WATER MANHOLE SIGN SIGN POST AND BOARD WATER POST INDICATOR VALVE CONTOUR SOILS LINE CURB WEST CAMPUS ADJACENT PROPERTY LINE FULL DEPTH PAVEMENT SIAMESE CONNECTION WATER LINE DOMESTIC WATER STUB OUT SANITARY SEWER WATER VALVE OVERHEAD ELECTRIC UNDERGROUND ELECTRIC WATER METER OVERHEAD TELEPHONE 1. UNDERGROUND TELEPHONE NO. STORM SEWER ISSUED FOR BID STORM SEWER ROOF DRAIN REVISIONS AND SUBMISSIONS WATER LINE FIRE CABLE TV MANHOLE DATE CABLE TV JUNCTION BOX COMMUNICATIONS MANHOLE COMMUNICATIONS HANDHOLE TELEPHONE HANDHOLE UNIDENTIFIED MANHOLE GENERAL NOTES AND LEGEND FIBER HANDHOLE TELEPHONE JUNCTION BOX UNIDENTIFIED PANEL BOX FIBER JUNCTION BOX FIBER MANHOLE TELEPHONE MANHOLE GAS METER UNIDENTIFIED PEDESTAL GAS MANHOLE TELEPHONE PANEL BOX AS NOTED UNIDENTIFIED VALVE GAS STUB OUT TELEPHONE PEDESTAL GAS VALVE EMERGENCY CALL STATION CS0002

3 BUILDING CODE SUMMARY Project Name Rowan CREATEs CODE REQUIREMENTS APPLICABLE CODES OCCUPANT LOAD (IBC Table ) HEIGHT MODIFICATIONS BUILDING DATA AREA MODIFICATIONS CONSTRUCTION CLASSIFCATION LIFE SAFETY SYSTEM BUILDING GROSS AREA (Foot Print) Required Hourly A0 WEST CAMPUS CODE SUMMARY X 03/02/ ISSUED FOR BID ALL DIMENSIONS MUST BE VERIFIED PROFESSIONAL NEW JERSEY LICENSE NO. X

4 A-1 WEST CAMPUS FLOOR PLAN AS NOTED JMcQ 03/02/ ISSUED FOR BID ALL DIMENSIONS MUST BE VERIFIED PROFESSIONAL NEW JERSEY LICENSE NO. X

5 ELEVATIONS A-2 WEST CAMPUS AS NOTED JMcQ 03/02/ ISSUED FOR BID ALL DIMENSIONS MUST BE VERIFIED PROFESSIONAL ARCHITECT

6 BUILDING SECTIONS & DETAILS A-3 WEST CAMPUS AS NOTED JMcQ 03/02/ ISSUED FOR BID ALL DIMENSIONS MUST BE VERIFIED PROFESSIONAL ARCHITECT

7 WALL SECTIONS A-4 WEST CAMPUS AS NOTED JMcQ 03/02/ ISSUED FOR BID ALL DIMENSIONS MUST BE VERIFIED PROFESSIONAL ARCHITECT

8 0 50' 100' CS0201 WEST CAMPUS EXISTING CONDITIONS PLAN 1" = 50' 1. ISSUED FOR BID ALL DIMENSIONS MUST BE VERIFIED

9 0 30' 60' CS0501 WEST CAMPUS DEMOLITION PLAN 1" = 30' 1. ISSUED FOR BID ALL DIMENSIONS MUST BE VERIFIED

10 ALL DIMENSIONS MUST BE VERIFIED MATCHLINE A-A BELOW MATCHLINE A-A ABOVE 1 LIGHT FIXTURE DETAIL (BASIS OF DESIGN) NOT TO SCALE WEST CAMPUS 8#6 VERTICAL HOOK ONE END PVC ADAPTER SET FOUNDATION 6" ABOVE GRADE IN LANDSCAPE/LAWN AREAS AND FLUSH IN PAVED SIDEWALK/PLAZA AREAS DATE 4'-0" FOR10'-15' POLES 5'-0" FOR 16' TO 25' POLES 6'-0" FOR 26' TO 30' POLES ANCHOR BOLTS 24" MIN. 1. 1" CHAMFER ALL EXPOSED EDGES NOT TO SCALE REVISIONS AND SUBMISSIONS 24" ROUND, 4000 PSI CONCRETE FOUNDATION; CONSULT WITH POLE MANUFACTURER FOR BOLT PATTERN FLOOD LIGHT FIXTURE DETAIL (BASIS OF DESIGN) NO. TROWEL FINISH ALL EXPOSED SURFACES 2 ISSUED FOR BID SEE LIGHT SCHEDULE FOR POLE TYPE AND COLOR SEE LIGHT SCHEDULE FOR POLE HEIGHT SINGLE OR DOUBLE LIGHT FIXTURES SITE PLAN PVC - SCHEDULE 40 RIGID STEEL CONDUIT #2/0 COPPER CADWELD #3 TIES 12" O.C. 3/4"x10' LONG COPPER GRD. ROD BOND TO ANCHOR BOLT, BALLAST AND GRD. WIRE AT EACH POLE. 1" = 30' 0 30' 60' 3 LIGHT FIXTURE POLE AND FOUNDATION DETAIL NOT TO SCALE CS1001

11 0 30' 60' CS1501 WEST CAMPUS GRADING AND DRAINAGE PLAN 1" = 30' 1. ISSUED FOR BID ALL DIMENSIONS MUST BE VERIFIED

12 MATCHLINE SEE DWG CS ' 60' CS1701 WEST CAMPUS UTILITY PLAN 1" = 30' 1. ISSUED FOR BID ALL DIMENSIONS MUST BE VERIFIED

13 MATCHLINE SEE DWG CS ' 60' CS1702 WEST CAMPUS UTILITY PLAN 1" = 30' 1. ISSUED FOR BID ALL DIMENSIONS MUST BE VERIFIED

14 0 30' 60' CS4001 WEST CAMPUS STORM SEWER PROFILES 1" = 30' 1. ISSUED FOR BID ALL DIMENSIONS MUST BE VERIFIED

15 0 30' 60' CS4501 WEST CAMPUS UTILITY PROFILES 1" = 30' 1. ISSUED FOR BID ALL DIMENSIONS MUST BE VERIFIED

CHECKLIST PRELIMINARY SUBDIVISION AND PRELIMINARY SITE PLAN

CHECKLIST PRELIMINARY SUBDIVISION AND PRELIMINARY SITE PLAN N/A Waiver (1) Four (4) copies of application form. (2) Fifteen (15) copies of plan (3) Subdivision/site plan application fee & professional review escrow deposit (4) Variance application fee & professional

More information

List of Figures. List of Forms

List of Figures. List of Forms City of Columbia Engineering Regulations PART 1: SUBMISSION OF PLANS Table of Contents Paragraph Description Page No. 1.1 General 1-1 1.2 Engineer s Report 1-1 1.3 Plans 1-3 1.4 Revisions to Approved Plan

More information

CITY OF TUMWATER 555 ISRAEL RD. SW, TUMWATER, WA (360)

CITY OF TUMWATER 555 ISRAEL RD. SW, TUMWATER, WA (360) CITY OF TUMWATER 555 ISRAEL RD. SW, TUMWATER, WA 98501 (360) 754-4180 Email: cdd@ci.tumwater.wa.us WATER-SEWER-STREET-STORM (IN CITY) Submittal Checklist TUM - RCVD BY DATE STAMP APPLICANT INFORMATION

More information

Washington County Road Engineering Plan Submittal/Review Checklist

Washington County Road Engineering Plan Submittal/Review Checklist Washington County Road Engineering Plan Submittal/Review Checklist Washington County Land Use Case File Number: Parcel(s): Developer/Owner Name(s): Developer/Owner E-mail(s): The following elements should

More information

Survey Requirements. Design Guidelines and Standards. June Office of the University Architect

Survey Requirements. Design Guidelines and Standards. June Office of the University Architect Design Guidelines and Standards Survey Requirements June 2004 Office of the University Architect Construction Management P.O. Box 210181 Cincinnati, Ohio 45221-0181 Table of Contents Survey Requirements

More information

STATE UNIVERSITY CONSTRUCTION FUND

STATE UNIVERSITY CONSTRUCTION FUND DIRECTIVE 1C-12 Issue date: August 2012 1. General SURVEY, MAPPING AND UTILITY LOCATING This Directive has been developed as a general guide for the survey and mapping effort required for Fund projects.

More information

Existing and proposed contours at 1-foot intervals. The fill and/or excavation quantities in cubic yards.

Existing and proposed contours at 1-foot intervals. The fill and/or excavation quantities in cubic yards. PLAN REQUIREMENTS The plans for street design shall conform to the requirements of Sections 3 and 4. The following requirements shall also be shown on the plans where applicable. Road and Storm Plans:

More information

ACSA PLAN REVIEW CHECKLIST (Guideline Only) (4) Standard water and sewer general plan notes (attached).

ACSA PLAN REVIEW CHECKLIST (Guideline Only) (4) Standard water and sewer general plan notes (attached). ACSA PLAN REVIEW CHECKLIST (Guideline Only) Revised: December 3, 2015 General (1) Proper Title (2) Vicinity map on first sheet. (3) Date and latest plan revision. (4) Standard water and sewer general plan

More information

EXCAVATION AND BACKFILL

EXCAVATION AND BACKFILL Standard Specification 2565.3, 2451, and 1805 A basic understanding of specifications is needed to properly replace the disturbed soil and restore the condition of the excavated area. The size of the disturbed

More information

CITY OF LA MARQUE CHAPTER GRAPHIC REQUIREMENTS CONSTRUCTION PLAN AND MISCELLANEOUS REQUIREMENTS

CITY OF LA MARQUE CHAPTER GRAPHIC REQUIREMENTS CONSTRUCTION PLAN AND MISCELLANEOUS REQUIREMENTS CITY OF LA MARQUE CHAPTER 2 -------------------------------------------- GRAPHIC REQUIREMENTS CONSTRUCTION PLAN AND MISCELLANEOUS REQUIREMENTS CHAPTER 2 ------------------------------------------------

More information

Application for Site Plan Review

Application for Site Plan Review Application for Site Plan Review 3275 Central Blvd., Hudsonville, Michigan 49426-1450, 616.669.0200 fax 616.669.2330 It is STRONGLY recommended that any application that must go before the Planning Commission

More information

ACWWA DRAWING SUBMITTAL INFORMATION - UTILITY DRAWING REQUIREMENTS

ACWWA DRAWING SUBMITTAL INFORMATION - UTILITY DRAWING REQUIREMENTS ACWWA DRAWING SUBMITTAL INFORMATION - UTILITY DRAWING REQUIREMENTS Detailed construction drawings for system extensions shall be prepared for approval with a submittal to the Authority. All construction

More information

SPECIFICATIONS FOR THE INSTALLATION OF CONDUIT SYSTEMS IN RESIDENTIAL SUBDIVISIONS. Notification of Completed Conduit Sections

SPECIFICATIONS FOR THE INSTALLATION OF CONDUIT SYSTEMS IN RESIDENTIAL SUBDIVISIONS. Notification of Completed Conduit Sections SPECIFICATIONS FOR THE INSTALLATION OF CONDUIT SYSTEMS IN RESIDENTIAL SUBDIVISIONS Section 1 Definitions 2 Scope of Work 3 Extent of Work 4 Inspection and Performance of Work 5 Trenching 6 Duct Installation

More information

MILL HILL ARTS VILLAGE

MILL HILL ARTS VILLAGE OWNER CIVIL ENGINEER MACON-BIBB URBAN DEVELOPMENT AUTHORITY ALEX MORRISON, EXECUTIVE DIRECTOR 200 CHERRY STREET, SUITE 300 MACON, GA 31201 OFFICE PHONE : (478) 803-2402 TRIPLE POINT ENGINEERING DAN WALLACE,

More information

Residential Construction Checklist Single and Two Family Construction

Residential Construction Checklist Single and Two Family Construction DATE: _ Building Inspection Submittal Requirements Residential Construction Checklist Single and Two Family Construction Submit a City of Big Spring Permit Application, checklist, and 3 complete hard copy

More information

PART 4 STANDARD DRAWINGS FOR CONSTRUCTION

PART 4 STANDARD DRAWINGS FOR CONSTRUCTION 4.0. INTRODUCTION PART 4 STANDARD DRAWINGS FOR CONSTRUCTION In this document, Ivins City adopts the most recent edition (currently 2007), including all amendments, of the APWA Utah Chapter s Manual of

More information

SECTION CHAIN LINK FENCING AND GATES AND SOFTBALL BACKSTOP

SECTION CHAIN LINK FENCING AND GATES AND SOFTBALL BACKSTOP 1 1 1 0 1 0 1 0 1 SECTION 1 1 CHAIN LINK FENCING AND GATES AND SOFTBALL BACKSTOP BASED ON DFD MASTER SPECIFICATION DATED /01/ P A R T 1 - G E N E R A L SCOPE The work under this section shall consist of

More information

SECTION 3 IMPROVEMENT PLAN REQUIREMENTS

SECTION 3 IMPROVEMENT PLAN REQUIREMENTS SECTION 3 IMPROVEMENT PLAN REQUIREMENTS CONTENTS Page 3-1 Digital Submittals 3-2 3-2 Paper Size and Scale 3-2 3-3 Drafting Standard 3-2 3-4 Title Sheet 3-2 3-5 Title Block 3-3 3-6 Drainage, Sewer, Water,

More information

.1 Applicability: These criteria shall be applied as follows:

.1 Applicability: These criteria shall be applied as follows: DESIGN CRITERIA DIVISION 4800 STREET LIGHTING 4801 GENERAL: These criteria shall be adhered to for the design of all publiclyfinanced or privately-financed traffic signal systems to be installed in the

More information

UTILITY AND STREET CONSTRUCTION PLAN REQUIREMENTS SECTION 1

UTILITY AND STREET CONSTRUCTION PLAN REQUIREMENTS SECTION 1 UTILITY AND STREET CONSTRUCTION PLAN REQUIREMENTS SECTION 1 ENGINEERING STANDARDS FOR UTILITY AND STREET CONSTRUCTION PLANS MARCH 2014 CONSTRUCTION PLAN SHEET FORMAT REQUIREMENTS REPRODUCIBLE MYLAR 1.

More information

SECTION TRACER WIRE FOR NONMETALLIC PIPE

SECTION TRACER WIRE FOR NONMETALLIC PIPE PART 1 GENERAL 1.1 DESCRIPTION A. The CONTRACTOR shall furnish and install a conductive tracer wire with all buried plastic water mains, services and appurtenances in accordance with the Water Utilities

More information

LOWNDES COUNTY ENGINEERING PLAN REVIEW CHECKLIST. Design Professional: Phone: Developer: Phone: 2 nd Submittal (No Fee)

LOWNDES COUNTY ENGINEERING PLAN REVIEW CHECKLIST. Design Professional: Phone: Developer: Phone: 2 nd Submittal (No Fee) MEMORANDUM MICHAEL B. FLETCHER, P.E. COUNTY ENGINEER 327 N. Ashley Street Valdosta, GA 31601 Telephone: (229) 671-2424 Fax: (229) 245-5299 mfletcher@lowndescounty.com LOWNDES COUNTY ENGINEERING PLAN REVIEW

More information

CITY OF LOMPOC DEVELOPMENT ASSISTANCE BROCHURE ENCROACHMENT PERMITS AND PUBLIC IMPROVEMENT PLANS

CITY OF LOMPOC DEVELOPMENT ASSISTANCE BROCHURE ENCROACHMENT PERMITS AND PUBLIC IMPROVEMENT PLANS CITY OF LOMPOC DEVELOPMENT ASSISTANCE BROCHURE E-10 ENCROACHMENT PERMITS AND PUBLIC IMPROVEMENT PLANS The City of Lompoc has determined that the Engineering Division should administer and issue Encroachment

More information

This addendum forms a part of the Contract Documents dated: August 10, 2012.

This addendum forms a part of the Contract Documents dated: August 10, 2012. Addendum # 1 Date Issued: August 28, 2012 Issued By: Project: Owner: Renker Eich Parks Architects 1609 Dr. Martin Luther King Street North St. Petersburg, Florida 33704 Ph# (727) 821-2986 Fax # (727) 896-4911

More information

B.2 MAJOR SUBDIVISION PRELIMINARY PLAN CHECKLIST

B.2 MAJOR SUBDIVISION PRELIMINARY PLAN CHECKLIST B.2 MAJOR SUBDIVISION PRELIMINARY PLAN CHECKLIST YES* GENERAL SUBMISSION ITEMS Does the submission include: 1. Thirteen (13) copies of completed Application Form? 2. Thirteen (13) copies of the Preliminary

More information

MINIMUM DRAWING REQUIREMENTS FOR WATER AND SEWER LINE PROJECTS

MINIMUM DRAWING REQUIREMENTS FOR WATER AND SEWER LINE PROJECTS Public Works Department Water & Wastewater Services WATER & WASTEWATER ENGINEERING DIVISION 2555 West Copans Road Pompano Beach, Florida 33369 954-831-0745 FAX 954-831-0798/0925 MINIMUM DRAWING REQUIREMENTS

More information

KC Water Rules and Regulations For Water Main Extensions and Relocations

KC Water Rules and Regulations For Water Main Extensions and Relocations KC Water Rules and Regulations For Water Main Extensions and Relocations MAY 2017 NOTE: Changes from 2016 are highlighted in yellow and appear on Pages 5, 8, 10-11, 13, and 15. Additional changes made

More information

Customer Connection Guide Updates Effective May 2017

Customer Connection Guide Updates Effective May 2017 This document provides a list of the updates to the EPCOR Distribution and Transmission Inc. (EDTI) Customer Connection Guide. If you have any questions, please contact EDTI Customer Engineering Services

More information

SECTION III STANDARD DRAWINGS ROYSE CITY GENERAL CONSTRUCTION NOTES & DETAILS

SECTION III STANDARD DRAWINGS ROYSE CITY GENERAL CONSTRUCTION NOTES & DETAILS 9. STANDARD DETAILS SECTION III STANDARD DRAWINGS ROYSE CITY GENERAL CONSTRUCTION NOTES & DETAILS j:\clerical\royse city\1-4086 general services\168-tech const standards review\tcss manual\2018 tcss manual\sec-9a

More information

SECTION 100 PRELIMINARY CONSIDERATIONS & INSTRUCTIONS

SECTION 100 PRELIMINARY CONSIDERATIONS & INSTRUCTIONS SECTION 100 PRELIMINARY CONSIDERATIONS & INSTRUCTIONS 101 General 102 Submittal Requirements A. Initial Submittal B. Second Submittal 103 Plan Requirements A. Subdivisions B. Site Plans 104 Approval of

More information

CITY OF MUSKEGO DRAFTING STANDARDS

CITY OF MUSKEGO DRAFTING STANDARDS CITY OF MUSKEGO DRAFTING STANDARDS GENERAL - These standards apply to all plans. 1. Plans must be prepared on sheets measuring 36 inch across and 22 inch to 24 inch high unless otherwise specified under

More information

TOWN of LAKESHORE SITE PLAN CHECKLIST

TOWN of LAKESHORE SITE PLAN CHECKLIST TOWN of LAKESHORE SITE PLAN CHECKLIST Last Revised December 17, 2009 Project Name: Project Location: Date Submitted: Name Phone Number E-mail Address Owner: Contractor/ Engineer: ( ) ( ) Applicant: ( )

More information

3. DESIGN SPECIFICATIONS

3. DESIGN SPECIFICATIONS Schedule H to Bylaw 7452, Subdivision Bylaw Page 10 3. DESIGN SPECIFICATIONS 3.1 General 3.1.1 The Design Specifications apply to the design of sanitary sewers, storm drains, waterworks, roadways, and

More information

Appendix C Construction Details

Appendix C Construction Details 7172 Kennedy Road Warrenton, Virginia 20187 Appendix C Construction Details November 2017 TABLE OF CONTENTS THRUST BLOCKS Anchorage for 11 1/4 o, 22 1/2 o & 45 o Upper Vertical Bends... AV 01 Buttresses

More information

City of Massillon Site Plan Checklist

City of Massillon Site Plan Checklist City of Massillon Site Plan Checklist The following information MUST be included with all Site Plans submitted for review and processing in order to constitute a complete Site Plan Package. Incomplete

More information

CHAPTER 11. Plan Standards

CHAPTER 11. Plan Standards CHAPTER 11 Plan Standards A. Introduction The city requires uniform public improvement plans for ease of record keeping and understanding. The following standards govern most plan submittals to the city.

More information

Plan Submittal and Review Checklist

Plan Submittal and Review Checklist Improving quality of life today creating a better tomorrow Plan Submittal and Review Checklist Version 1.2 September 4, 2017 Contents Overview... 2 Plan Submittal Checklist... 2 Plan Review Checklist -

More information

SITE PLAN, SUBDIVISION & EXTERIOR DESIGN REVIEW PROCESS

SITE PLAN, SUBDIVISION & EXTERIOR DESIGN REVIEW PROCESS INCORPORATED VILLAGE OF ROCKVILLE CENTRE BUILDING DEPARTMENT SITE PLAN, SUBDIVISION & EXTERIOR DESIGN REVIEW PROCESS Presubmission - Prior to a formal submission, the applicant should meet in person with

More information

SECTION DEWATERING PART 1 - GENERAL 1.1 RELATED DOCUMENTS

SECTION DEWATERING PART 1 - GENERAL 1.1 RELATED DOCUMENTS SECTION 312319 - DEWATERING PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections,

More information

Section E NSPS MODEL STANDARDS FOR TOPOGRAPHIC SURVEYS Approved 3/12/02

Section E NSPS MODEL STANDARDS FOR TOPOGRAPHIC SURVEYS Approved 3/12/02 Section E NSPS MODEL STANDARDS FOR TOPOGRAPHIC SURVEYS Approved 3/12/02 1. INTRODUCTION This standard is written to provide the professional surveyor (Surveyor) and the client with a guideline for producing

More information

A. Deviation from this standard must be approved by the Project Architect.

A. Deviation from this standard must be approved by the Project Architect. September 2012, rev. 00 26 5600 Exterior Lighting PART 1. GENERAL 1.01 Related Documents A. Deviation from this standard must be approved by the Project Architect. B. Drawings and general provisions of

More information

SECTION III SUBMITTALS AND APPROVALS

SECTION III SUBMITTALS AND APPROVALS SECTION III SUBMITTALS AND APPROVALS In order to expedite the approval process of new water distribution system and sanitary sewer collection system extensions, the Hilton Head No. 1 Public Service District

More information

SECTION DEWATERING TANKAGE PART 1 - GENERAL 1.1 RELATED DOCUMENTS

SECTION DEWATERING TANKAGE PART 1 - GENERAL 1.1 RELATED DOCUMENTS SECTION 31 23 19 - DEWATERING TANKAGE PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 1 Specification

More information

MANHOLES PART I: GENERAL. A. Precast Concrete Manholes

MANHOLES PART I: GENERAL. A. Precast Concrete Manholes MANHOLES PART I: GENERAL A. Precast Concrete Manholes 1) Manholes shall be made of precast concrete sections of which the top section shall be eccentric or flat slab top. The bottom section shall be a

More information

WATER & SEWER CONSTRUCTION SITE PLAN DESIGN SUMMARY COMMERCIAL & RESIDENTIAL

WATER & SEWER CONSTRUCTION SITE PLAN DESIGN SUMMARY COMMERCIAL & RESIDENTIAL WATER & SEWER CONSTRUCTION SITE PLAN DESIGN SUMMARY COMMERCIAL & RESIDENTIAL This summary is not all inclusive of the requirements set forth by the York County Planning & Development Services, York County

More information

BRASELTON WATER AND WASTEWATER DEPARTMENT CONSTRUCTION PLAN REVIEW CHECKLIST May 2006

BRASELTON WATER AND WASTEWATER DEPARTMENT CONSTRUCTION PLAN REVIEW CHECKLIST May 2006 Project Name: BRASELTON WATER AND WASTEWATER DEPARTMENT CONSTRUCTION PLAN REVIEW CHECKLIST May 2006 Phase: Unit: # Lots: Development Type (residential, commercial, industrial, etc.) Braselton Project No.

More information

SECTION 58 PRECAST CONCRETE BOX CULVERT. This work consists of furnishing and installing Pre-cast Concrete Box Culverts.

SECTION 58 PRECAST CONCRETE BOX CULVERT. This work consists of furnishing and installing Pre-cast Concrete Box Culverts. SECTION 58 PRECAST CONCRETE BOX CULVERT 58.1 DESCRIPTION A. General This work consists of furnishing and installing Pre-cast Concrete Box Culverts. B. Related Work Section 51 Section 52 Section 53 Section

More information

CITY OF PITTSBURG ENGINEERING DEPARTMENT CONTRACT NO A WATER TREATEMENT PLANT CAPITAL IMPROVEMENTS PHASE 1A ADDENDUM #1 FENCE AND DITCH AUGUST

CITY OF PITTSBURG ENGINEERING DEPARTMENT CONTRACT NO A WATER TREATEMENT PLANT CAPITAL IMPROVEMENTS PHASE 1A ADDENDUM #1 FENCE AND DITCH AUGUST CITY OF PITTSBURG ENGINEERING DEPARTMENT CONTRACT NO. 2012-16A WATER TREATEMENT PLANT CAPITAL IMPROVEMENTS PHASE 1A ADDENDUM #1 FENCE AND DITCH AUGUST 2014 CHAIN LINK FENCE SPECIFICATIONS Chain link fence,

More information

Sewer Line Extension Permit Design Checklist

Sewer Line Extension Permit Design Checklist CHECKLIST C1 Revised 4/7/2017 Sewer Line Extension Permit Design Checklist DISCLAIMER - This checklist is provided to Consulting Engineers for the express purpose of assisting them in compiling sewer line

More information

September 21, Mannik Smith Group 1771 North Dixie Highway Monroe, Michigan RE: LA Fitness City File No.: CVLP

September 21, Mannik Smith Group 1771 North Dixie Highway Monroe, Michigan RE: LA Fitness City File No.: CVLP CITY OF ANN ARBOR, MICHIGAN Public Services Area / Engineering 301 E. Huron Street, P.O. Box 8647 Ann Arbor, Michigan 48107 Phone (734) 794-6410 Fax (734) 994-1744 Web: www.a2gov.org Printed on recycled

More information

SECTION SITE SURVEYS

SECTION SITE SURVEYS SECTION 02 21 13 SITE SURVEYS SPEC WRITER NOTE: 1. Delete text between // // not applicable to project. Edit remaining text to suit project. 2. Use this section to specify survey required before design

More information

SECTION 39 - MANHOLES TABLE OF CONTENTS

SECTION 39 - MANHOLES TABLE OF CONTENTS SECTION 39 - MANHOLES TABLE OF CONTENTS Section Page 39-1 GENERAL... 39.1 39-2 PRECAST CONCRETE MANHOLES... 39.1 39-2.01 Precast Concrete Sewer Manholes... 39.1 39-2.02 Precast Concrete Storm Drain Manholes...

More information

A. Dewatering observation wells are part of dewatering allowance.

A. Dewatering observation wells are part of dewatering allowance. SECTION 312319 - DEWATERING PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections,

More information

7000 Fifteen Mile Road Sterling Heights, Michigan

7000 Fifteen Mile Road Sterling Heights, Michigan 7000 Fifteen Mile Road Sterling Heights, Michigan Industrial Building With Excess Land and Rail Access As exclusive agents, we are pleased to offer the following property for lease: 128,648 Sq. Ft. Completely

More information

Porter County Plan Commission

Porter County Plan Commission Plan Type: Development Plan Administrative DRC PC Primary Plan Administrative DRC PC Secondary Plat/Replat Administrative DRC PC PUD Conceptual Detailed Final Project Information Project Name: Developer

More information

SANITARY SEWER SYSTEM ADMINISTRATIVE STANDARDS A.1 SANITARY SEWER SYSTEM PLAN SUBMITTAL PROCEDURES AND GENERAL REQUIREMENTS

SANITARY SEWER SYSTEM ADMINISTRATIVE STANDARDS A.1 SANITARY SEWER SYSTEM PLAN SUBMITTAL PROCEDURES AND GENERAL REQUIREMENTS SANITARY SEWER SYSTEM ADMINISTRATIVE STANDARDS A.1 SANITARY SEWER SYSTEM PLAN SUBMITTAL PROCEDURES AND GENERAL REQUIREMENTS All plans for sanitary sewer main extensions, improvements and modifications

More information

For crossing under a railroad, contact the specific railroad company's engineering department.

For crossing under a railroad, contact the specific railroad company's engineering department. PAGE 330524-1 SECTION 330524 SPECIFIER: This section is for the underground installation of piping by directional drilling. When specifying this method of piping installation, care must be taken to ensure

More information

PROGRAMMING SCHEMATIC DESIGN DESIGN DEVELOPMENT CONSTRUCTION DOCUMENTS. room) Scalable bubble diagrams schedules describing programmatic

PROGRAMMING SCHEMATIC DESIGN DESIGN DEVELOPMENT CONSTRUCTION DOCUMENTS. room) Scalable bubble diagrams schedules describing programmatic GENERAL SITE PROGRAMMING SCHEMATIC DESIGN DESIGN DEVELOPMENT CONSTRUCTION DOCUMENTS Scope of work narrative Building code review Description of construction Documentation on drawings as List of applicable

More information

Grease Interceptor Design Checklist

Grease Interceptor Design Checklist CHECKLIST C2 Revised 5/2/2016 Grease Interceptor Design Checklist Public Works DISCLAIMER - This checklist is provided to Consulting Engineers for the express purpose of assisting them in compiling private

More information

1.1 GENERAL RECORD DRAWING REQUIREMENTS

1.1 GENERAL RECORD DRAWING REQUIREMENTS Page 1 of 5 VILLAGE OF ROMEOVILLE RECORD DRAWINGS CHECKLIST PART I GENERAL Record drawings are required to provide a means of schematic verification that the intent of the approved engineering design has

More information

Page Electric Utility Service Specifications

Page Electric Utility Service Specifications T Y P I C A L U N D E R G R O U N D S E R V I C E R E Q U I R E M E N T S 200 Amps Maximum - UG-1 Sheet 1 of 3 87 T Y P I C A L U N D E R G R O U N D S E R V I C E R E Q U I R E M E N T S 200 Amps Maximum

More information

DESIGN GUIDELINES (SD) COUNTY OF ALAMEDA PUBLIC WORKS AGENCY 399 ELMHURST STREET HAYWARD, CA

DESIGN GUIDELINES (SD) COUNTY OF ALAMEDA PUBLIC WORKS AGENCY 399 ELMHURST STREET HAYWARD, CA DESIGN GUIDELINES (SD) COUNTY OF ALAMEDA PUBLIC WORKS AGENCY 399 ELMHURST STREET HAYWARD, CA 94544-1395 PUBLIC WORKS DESIGN GUIDELINES TABLE OF CONTENTS SD-100 SERIES SPECIAL DRAWINGS SD-100 8/1991 SILT

More information

Operating Standards Attachment to Development Application

Operating Standards Attachment to Development Application Operating Standards Attachment to Development Application Planning & Development Services 2255 W Berry Ave. Littleton, CO 80120 Phone: 303-795-3748 Mon-Fri: 8am-5pm www.littletongov.org SITE DEVELOPMENT

More information

APPENDIX 1: CONSTRUCTION PLAN CHECKLIST

APPENDIX 1: CONSTRUCTION PLAN CHECKLIST APPENDIX 1: CONSTRUCTION PLAN CHECKLIST October 2017 APPENDIX A APPENDIX 1: CONSTRUCTION PLAN CHECKLIST ALL PLANS Plans on 24-inch by 36-inch paper (Originals shall be transmitted on a CD as an electronic

More information

1. Land survey Work. 2. Civil and Structural engineering services.

1. Land survey Work. 2. Civil and Structural engineering services. SECTION 01050 FIELD ENGINEERING PART 1 - GENERAL 1.01 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and other Division-1 Specification

More information

CITY OF BEVERLY HILLS Department of Public Works and Transportation Civil Engineering Division STREET/ALLEY IMPROVEMENT PLAN REVIEW CHECKLIST

CITY OF BEVERLY HILLS Department of Public Works and Transportation Civil Engineering Division STREET/ALLEY IMPROVEMENT PLAN REVIEW CHECKLIST CITY OF BEVERLY HILLS Department of Public Works and Transportation Civil ing Division STREET/ALLEY IMPROVEMENT PLAN REVIEW CHECKLIST The following checklist consists of the minimum requirements for preparation

More information

Item 550 Chain Link Fence

Item 550 Chain Link Fence Item Chain Link Fence 1. DESCRIPTION 2. MATERIALS Furnish, install, remove, repair, or replace chain link fence and gates. Furnish certification from the chain link fence materials manufacturer stating

More information

CITY OF BEVERLY HILLS Department of Public Works and Transportation Civil Engineering Division SANITARY SEWER IMPROVEMENT PLAN REVIEW CHECKLIST

CITY OF BEVERLY HILLS Department of Public Works and Transportation Civil Engineering Division SANITARY SEWER IMPROVEMENT PLAN REVIEW CHECKLIST CITY OF BEVERLY HILLS Department of Public Works and Transportation Civil ing Division SANITARY SEWER IMPROVEMENT PLAN REVIEW CHECKLIST The following checklist consists of the minimum requirements for

More information

Public Works City of Lebanon, Tennessee; Department of Public Works

Public Works City of Lebanon, Tennessee; Department of Public Works SECTION 1 GENERAL 1. DEFINITIONS Public Works City of Lebanon, Tennessee; Department of Public Works City City of Lebanon, Wilson County, Tennessee City Engineer Employed by the City of Lebanon, Registered

More information

SPECIFICATIONS FOR THE INSTALLATION OF CONDUIT SYSTEM(S) FOR STREETLIGHTS. 1 Definitions. 2 Scope of Work. 3 Extent of Work

SPECIFICATIONS FOR THE INSTALLATION OF CONDUIT SYSTEM(S) FOR STREETLIGHTS. 1 Definitions. 2 Scope of Work. 3 Extent of Work SPECIFICATIONS FOR THE INSTALLATION OF CONDUIT SYSTEM(S) FOR STREETLIGHTS Section 1 Definitions 2 Scope of Work 3 Extent of Work 4 Inspection and Performance of Work 5 Trenching 6 Duct Installation 7 Backfilling

More information

STANDARD BID ITEM NUMBERS

STANDARD BID ITEM NUMBERS 10701 TRAFFIC CONTROL LUMP SUM 10702 Traffic Control for Storm Sewer Installation LUMP SUM 10703 Traffic Control for Water Main Installation LUMP SUM 10704 Traffic Control for Sanitary Sewer Installation

More information

5.7 Plan Documentation and Supporting Information.

5.7 Plan Documentation and Supporting Information. 5.7 and Supporting Information. In any case where the and Supporting Information for a Development Plan requires the submission of a Site Plan, Overall Plan, Landscape Plan, Building Elevations, Sign Plan

More information

Site Plan/Building Permit Review

Site Plan/Building Permit Review Part 6 Site Plan/Building Permit Review 1.6.01 When Site Plan Review Applies 1.6.02 Optional Pre- Application Site Plan/Building Permit Review (hereafter referred to as Site Plan Review) shall be required

More information

CONSTRUCTION SPECIFICATION FOR MAINTENANCE HOLE, CATCH BASIN, DITCH INLET, AND VALVE CHAMBER INSTALLATION

CONSTRUCTION SPECIFICATION FOR MAINTENANCE HOLE, CATCH BASIN, DITCH INLET, AND VALVE CHAMBER INSTALLATION ONTARIO PROVINCIAL STANDARD SPECIFICATION METRIC OPSS 407 NOVEMBER 2013 CONSTRUCTION SPECIFICATION FOR MAINTENANCE HOLE, CATCH BASIN, DITCH INLET, AND VALVE CHAMBER INSTALLATION TABLE OF CONTENTS 407.01

More information

CITY OF APACHE JUNCTION DEVELOPMENT SERVICES CIVIL ENGINEERING PLAN REVIEW CHECKLIST PROJECT: LOCATION:

CITY OF APACHE JUNCTION DEVELOPMENT SERVICES CIVIL ENGINEERING PLAN REVIEW CHECKLIST PROJECT: LOCATION: CITY OF APACHE JUNCTION DEVELOPMENT SERVICES CIVIL ENGINEERING PLAN REVIEW CHECKLIST PROJECT: LOCATION: LOG NO.: LEGEND REVIEW REVIEWED BY DATE / - Requirement satisfied 1 O Requirement not satisfied 2?

More information

City of Vaughan Engineering Department DESIGN STANDARD DRAWINGS

City of Vaughan Engineering Department DESIGN STANDARD DRAWINGS City of Vaughan Engineering Department DESIGN STANDARD DRAWINGS March 2004 STANDARD DRAWINGS Partners With The Environment March 2004 FORWARD The March 2004 version of the City of Vaughan Design Standard

More information

Record Drawing Standards for Projects Version 2.1

Record Drawing Standards for Projects Version 2.1 for Projects Version 2.1 Updated September 21, 2016 Department: Spatial Data Group Engineering & Maintenance 1. INTRODUCTION... 1 2. GENERAL STANDARDS... 1 2.1 Drawing Standards... 1 2.2 Digital Submission

More information

Essential Skills: Reading and Interpreting Maps and Plans

Essential Skills: Reading and Interpreting Maps and Plans Essential Skills: Reading and Interpreting Maps and Plans Prepared for: NEW YORK STATE PLANNING FEDERATION April 14, 2015 Prepared by: BME ASSOCIATES Peter G. Vars, P.E. Stages of Plan Review Concept /

More information

CHAPTER 29 PROJECT COMPLETION DOCUMENTS

CHAPTER 29 PROJECT COMPLETION DOCUMENTS CHAPTER 29 PROJECT COMPLETION DOCUMENTS PROJECT COMPLETION Upon completion of traffic control signal system and lighting projects, there are forms and checklists to ensure that the project is closed out

More information

SECTION MANHOLES

SECTION MANHOLES SECTION 33 05 13 MANHOLES PART 1 GENERAL 1.01 SECTION INCLUDES A. CONTRACTOR shall furnish and install precast concrete manhole base, sections, adjusting rings, steps, and manhole ring and cover, complete.

More information

Anne Arundel County Dept. of Inspections and Permits Water Sewer Plan Checklist

Anne Arundel County Dept. of Inspections and Permits Water Sewer Plan Checklist Project Name Project Number Engineer Plans are to be designed based on the standards set forth in the Anne Arundel County Design Manual Standards and Specifications, and all other manuals as stipulated

More information

SECTION 2 GENERAL REQUIREMENTS

SECTION 2 GENERAL REQUIREMENTS SECTION 2 GENERAL REQUIREMENTS 2-1 ENGINEER REQUIRED: All plans and specifications for Improvements which are to be accepted for maintenance by the County and private, on-site drainage and grading shall

More information

CITY OF BEVERLY HILLS Department of Public Works and Transportation Civil Engineering Division STORM DRAIN IMPROVEMENT PLAN REVIEW CHECKLIST

CITY OF BEVERLY HILLS Department of Public Works and Transportation Civil Engineering Division STORM DRAIN IMPROVEMENT PLAN REVIEW CHECKLIST CITY OF BEVERLY HILLS Department of Public Works and Transportation Civil ing Division STORM DRAIN IMPROVEMENT PLAN REVIEW CHECKLIST The following checklist consists of the minimum requirements for preparation

More information

Minimum Drawing & Electronic Submittal Requirements For Record Drawings /As-Builts

Minimum Drawing & Electronic Submittal Requirements For Record Drawings /As-Builts Minimum Drawing & Electronic Submittal Requirements For Record Drawings /As-Builts PUBLIC WORKS ENGINEERING DEPARTMENT Revised: February 1, 2017 MINIMUM DRAWING REQUIREMENTS A. GENERAL PLAN REQUIREMENTS:

More information

DRAFTING STANDARDS 9.00 DRAFTING STANDARDS

DRAFTING STANDARDS 9.00 DRAFTING STANDARDS DRAFTING STANDARDS 9.00 DRAFTING STANDARDS Final plans shall conform in appearance, format, accuracy, and quality to the standards used in the Springfield Engineering Division. Additional standards shall

More information

Guidelines and Checklist For SAWS Sanitary Sewer. Developmental Engineering Division

Guidelines and Checklist For SAWS Sanitary Sewer. Developmental Engineering Division Guidelines and Checklist For SAWS Sanitary Sewer Developmental Engineering Division INITIAL CONSIDERATIONS UTILITY SERVICE AGREEMENT Utility Service Agreement A Utility Service Agreement (USA) will be

More information

Plan Preparation Checklist

Plan Preparation Checklist Appendix D Plan Preparation Checklist It is the responsibility of the Designer to complete and submit this checklist along with all required drawings for OUC (EFP) Review. All drawings submitted for OUC

More information

Peters Township Sanitary Authority 3244 Washington Road McMurray, PA 15317

Peters Township Sanitary Authority 3244 Washington Road McMurray, PA 15317 3244 Washington Road McMurray, PA 15317 (724) 941-6709 Appendix C Developer Information PETERS TOWNSHIP SANITARY AUTHORITY SEWER USE RULES AND REGULATIONS APPENDIX C Procedures and Requirements for Land

More information

MARQUETTE GREENWAY TRAIL

MARQUETTE GREENWAY TRAIL ------ ------ TRAFFIC DATA A.A.D.T. (2010) A.A.D.T. (ED 2022) D.H.V. (2022) DIRECTIONAL DISTRIBUTION TRUCKS N/A N/A N/A N/A N/A DESIGN DATA DESIGN SPEED DESIGN CRITERIA FUNCTIONAL CLASSIFICATION RURAL/URBAN

More information

ADDENDUM #2 September 12, 2018

ADDENDUM #2 September 12, 2018 Physical Plant Services Project Management 1000 Rim Drive Phone: (970) 247-7523 Fax: (970) 247-7555 Project No. 2007-130P18 Whalen Gymnasium Expansion and Renovation for Exercise Science Request for Qualifications

More information

Authorized Agent: City of Manassas Check List Attached: Contact: Address: Phone Number: Fax Number: Developer s Name: Phone Number:

Authorized Agent: City of Manassas Check List Attached: Contact:   Address: Phone Number: Fax Number: Developer s Name: Phone Number: CITY OF MANASSAS DEPARTMENT OF COMMUNITY DEVELOPMENT DEVELOPMENT SERVICES DIVISION 9027 Center Street Room 201 Manassas, Virginia, 20110 Phone: 703-257-8278 Fax: 703-257-5831 Application Date: APPLICANT

More information

Excavating, Backfilling, and Compaction for Utilities Piping (Plumbing).

Excavating, Backfilling, and Compaction for Utilities Piping (Plumbing). SECTION 15047 - IDENTIFICATION PART 1 GENERAL 1.01 SUMMARY A. Section Includes: Identification including necessary accessories indicated on Construction Documents and specified in this section or as required

More information

Anne Arundel County Dept. of Inspections and Permits Storm Drain Checklist

Anne Arundel County Dept. of Inspections and Permits Storm Drain Checklist Project Name Project Number Engineer Plans are to be designed based on the standards set forth in the Anne Arundel County Design Manual Standards and Specifications, and all other manuals as stipulated

More information

Minor Site Plan Application and Checklist Land Disturbing Activities

Minor Site Plan Application and Checklist Land Disturbing Activities Minor Site Plan Application and Checklist Land Disturbing Activities INSTRUCTIONS: Please provide the requested information below. The Development Services Department reviews each site plan submittal based

More information

StormTrap Guide Specification. StormTrap 2 SingleTrap on Aggregate Foundation Groundwater BELOW Invert Revised 11/30/17

StormTrap Guide Specification. StormTrap 2 SingleTrap on Aggregate Foundation Groundwater BELOW Invert Revised 11/30/17 StormTrap Guide Specification StormTrap 2 SingleTrap on Aggregate Foundation Groundwater BELOW Invert Revised 11/30/17 This product guide specification is written according to the Construction Specifications

More information

SECTION PRECAST CONCRETE SECTIONAL MANHOLES

SECTION PRECAST CONCRETE SECTIONAL MANHOLES SECTION 02545 PRECAST CONCRETE SECTIONAL MANHOLES PART 1 - GENERAL 1.01 SUMMARY A. Section Includes: 1. Precast reinforced concrete cylindrical sectional manholes, complete with openings, inserts, hardware,

More information

LARAMIE COUNTY PLANNING & DEVELOPMENT OFFICE 3966 Archer Pkwy Cheyenne, WY Phone (307) Fax (307)

LARAMIE COUNTY PLANNING & DEVELOPMENT OFFICE 3966 Archer Pkwy Cheyenne, WY Phone (307) Fax (307) 3966 Archer Pkwy Cheyenne, WY 82009 planning@laramiecounty.com Phone (307) 633-4303 Fax (307) 633-4616 SITE PLAN REVIEW PROCESS 1. Pre-Application Meeting: The applicant shall meet with a Laramie County

More information

Town of Apex, North Carolina

Town of Apex, North Carolina POND DRAINAGE PLAN APPLICATION Town of Apex, North Carolina POND DRAINAGE PLAN APPLICATION: Applications are due by 12:00 pm on the first business day of each month. Please see the Minor Site Plan Schedule

More information

SITE PLAN Application Packet (Required For All Non-Residential Development Projects)

SITE PLAN Application Packet (Required For All Non-Residential Development Projects) SITE PLAN Application Packet (Required For All Non-Residential Development Projects) Community Development Department 90 North Main Street, Tooele, UT 84074 (435) 843-2130 Fax (435) 843-2139 Dear Applicant,

More information

RESIDENTIAL DEMOLITION PERMIT APPLICANT CHECKLIST

RESIDENTIAL DEMOLITION PERMIT APPLICANT CHECKLIST RESIDENTIAL DEMOLITION PERMIT APPLICANT CHECKLIST The purpose of this form is to inform applicants of: 1) the requirements for building permits and stormwater permits for residential demolition projects;

More information