ISOMAG Millennium ML 210 A QUADRO 210 PANEL MOUNTING VERSION ML 210 VERSIONE A PARETE ML 210 WALL VERSION
|
|
- Oswin Foster
- 6 years ago
- Views:
Transcription
1 M I S U R A T O R I E L E T T R O M A G N E T I C I D I P O R T A T A S E R I E E L E C T R O M A G N E T I C F L O W M E T E R S E R I E S ISOMAG Millennium C ONVER TER M OD EL M L CONVERTITORE PER MISURATORE ELETTROMAGNETICO DI PORTATA CON DISPLAY GRAFICO CONVERTER FOR ELECTROMAGNETIC FLOW METER WITH GRAPHICAL DISPLAY ML 210 A QUADRO 210 PANEL MOUNTING VERSION ML 210 VERSIONE A PARETE ML 210 WALL VERSION
2 SPECIFICA TECNICA Data Documento 15/10/03 Pagine 2/7 STO82 02 DATA SHEET ML DATI TECNICI / TECHNICAL DATA Materiale custodia Material box Alluminio pressofuso verniciato / Painted aluminum die casting AISI 304 / SS AISI 304 Dimensioni / Dimension 140 X 140 X 160 mm Protezione / Protection rate IP 67 Cavi connessione Sens. / Press. Conn. sensor cable/ Cable gland CABLE C015 - C016 / N 6 PRESS CABLE GLAND PG 11 Temperatura ambiente/ Amb. Temperature C / F Display LCD Display grafico 8 righe X 16 caratteri 128 X 64 pixel retroilluminato Graphic display 8 lines x 16 Characters 128x64 pixel with back light Tastiera di programmazione Programming keyboard N 3 tasti a membrana / 3 membrane keys Uscita impulsi / frequenza Pulse / frequency output N 2, 1250 Hz, 100mA, 40 Vdc (12,5 KHz Opz. / Opt.) Uscita corrente / Current output N 1, 0/4 20mA RL=1000W (+1 Opz. / Opt. ) Ingresso digitale / Digital input N 1, Funzione programmabile / programmable function Uscita allarme / Alarm output N 2, Funzioni programmabili / programmable function Data logger 32 valori + 64 eventi allarme / 32 values + 64 alarm events Misura bidirezionale Bi-directional Sì / Yes Doppio campo / Dual range Sì / Yes Valore di F.S. / FS value 0,4 10m/s Interfaccia di comunicazione Communication Interface RS 485 (RS232 Opz. / Opt. ) / Profibus DP (RS232 Opz. / Opt. ) Funzione di autodiagnosi Diagnostic funct. Sì / Yes Rilevazione tubo vuoto Empty pipe detect. Sì / Yes Tutti gli ingressi e le uscite sono separati tra loro e dall alimentazione Separazione galvanica fino a 500 V Galvanic isolation All the inputs / outputs are galvanically isolated from power supply up to 500 V Memorizzazione dati Data storage Presa programmazione Programming plug in Funzione Dosaggio Bacth function Certificazione CE CE certification Incertezza delle misure Measurements tolerance In mancanza di alimentazione i dati vengono memorizzati in una Eeprom Eeprom stored measuring values on power failure Presa protetta per collegamento PC o terminale portatile Protected plug in for connection to PC or hand terminal Sì / Yes Strumento certificato CE / Instrument with CE certificate classe I, IP 67, categoria d installazione II / class I, IP 67, category of installation II Portata ( volume) = ±0,05% v.l. / Flow rate (volume) = ±0,05% v.l. Out 4/20 ma = ± 0,08 % v.l. Out Frequenza = ± 0,08% v.l. / Frequency Out = ± 0,08% v.l. Ripetibilità / Ripetibility Migliore dello 0,01% / Better than 0,01% Altitudine / Altitude da 200 m a 6000 m / up to ft Range umidità / Humidity Range 0 100% (IP 67) Alimentazione / Power supply Vac Hz; 10 63Vdc/15 45 Vac-45 66Hz; Vdc Consumo max / max Consumption 25VA 23VA 21W Revisione N 1 15/10/03 AGGIUNTO DIMENSIONI D INGOMBRO
3 SPECIFICA TECNICA Data Documento 15/10/03 Pagine 3/7 STO82 02 DATA SHEET ML DIMENSIONI D INGOMBRO / OVERALL DIMENSIONS ( VERSIONE COMPATTA- PARETE / WALL-COMPACT VERSION ) * * : DIMENSIONE VERSIONE COMPATTA COMPACT VERSION DIMENSION Revisione N 1 15/10/03 AGGIUNTO DIMENSIONI D INGOMBRO
4 SPECIFICA TECNICA Data Documento 15/10/03 Pagine 4/7 STO82 02 DATA SHEET ML DIMENSIONI D INGOMBRO / OVERALL DIMENSIONS ( VERSIONE A QUADRO / PANEL MOUNTING VERSION ) MORSETTI / TERMINAL BLOCK Revisione N 1 15/10/03 AGGIUNTO DIMENSIONI D INGOMBRO
5 SPECIFICA TECNICA Data Documento 15/10/03 Pagine 5/7 STO82 02 DATA SHEET ML FUNZIONI DISPONIBILI / AVAILABLE FUNCTIONS 1.SENSOR 1.1 ND 1.2 COEFF. KA 1.3 COEFF. KL+ / KL- 1.4 CABLE LEN. 1.5 E.P. DETECT 1.6 AUTOZERO CAL. 1.7 E.P. CALIBR. SET ND SET KA SET KL SET CABLE LENGTH ON/OFF AUTOZERO CALIBRATION EMPTY PIPE CALIBRATION EMPTY PIPE TEST 2.SCALES 2.1 FS1 2.2 FS1 2.3 MU.TOT 2.4 IMP1 2.5 IMP2 2.6 TPUL1 2.7 TPUL2 2.8 FRQ1 2.9 FRQ SW FULL SCALE 1 VALUE SET FULL SCALE 2 VALUE SET MEASURE UNIT PULSE CHANNEL 1 PULSE CHANNEL 2 T PULSE CHANNEL 1 T PULSE CHANNEL 2 FULL SCALE FREQ. CHAN. 1 FULL SCALE FREQ. CHAN. 2 SPECIFIC GRAVITY SET VOLUME UNIT VOLUME UNIT TYPE OF UNIT MISURE UNIT MISURE UNIT TYPE OF UNIT TYPE OF UNIT N DECIMAL TOTALIZER TYPE OF UNIT TYPE OF UNIT TIME UNIT OF MEASURE TIME UNIT OF MEASURE NUMERIC VALUE NUMERIC VALUE NUMERIC VALUE NUMERIC VALUE 3.MEASURE 3.1 T. CONST 3.2 FILTER 3.3 SKIP THR 3.4 PEAK THR 3.5 CUT-OFF 3.6 AUTOCAL. 3.7 ATORANGE 3.8 E. SAVING TIME CONTANT SET ENABLE FILTRE 50/60Hz ACCELERATION TH. SET PICK CUT OFF TH. SET LOW FLOW TH. SET AUTOCALIB FUNCTION AUTOMATIC CHANGE SCALE ENERGY SAVING 4.ALARMS 4.1 MAX THR MAX THR MIN THR MIN THR HYST 4.6 E.P. THR 4.7 ma VAL.FAULT 4.8 Hz VAL.FAULT 4.9 TIMEOUT MAX + FLOW ALARM SET MIN - FLOW ALARM SET MIN + FLOW ALARM SET MIN - FLOW ALARM SET HYSTERESIS THRESHOLD E. P. THRESHOLD SET 4/20 ma ALARM SET FREQ. OUTPUT ALARM SET BATCH SAFETY TIMER 5.INPUTS 5.1 T+ RESET 5.2 P+ RESET 5.3 T- RESET 5.4 P- RESET 5.5 PULS.RESET 5.6 COUNT LOCK 5.7 CALIBRATION 5.8 RANGE CHANGE 5.8 BATCH 5.9 INP. 2 RES.TOTAL + FLOW PARTIAL + FLOW TOT. RES.TOTAL - FLOW PARTIAL - FLOW TOT. RESET PULSE TOTALISER LOCK TOTALISER AUTOZERO EXT. COM. CHANGE EXTERNAL COM. START/STOP BATCH SEE FUNCTION FOR INPUT 2 FUNCTION ACTIVE WITH INPUT IN VOLTAGE FUNCTION ACTIVE WITH INPUT IN VOLTAGE 6.OUTPUTS 6.1 OUT OUT OUT.3 6.4OUT.4 (MAX 12.5KHz) (OPT.) 6.5 DUTYCYCLE OUT.mA1 6.7 OUT.mA2 (OPT.) SEE THE TAB REFER TO THE FUNCTIONS FOR OUTPUTS: MENU 6 "OUTPUT" DUTYCYCLE ON OUT 1-2 CURRENT VALUE OUTPU 1 RANGE (0/4-20/22 ma) FIELD (+,-,±,-0+) CURRENT VALUE OUTPUT 2 RANGE (0/4-20/22 ma FIELD (+,-,±,-0+) 7. COM. 7.1 ADDRESS 7.2 SPEED SPEED PRINT (OPT.) 7.5 PRINTER 7.6 PRINT DATA 7.7 PRINT EVENTS NETWORK ADDRESS SET SPEED RS485 OUTPUT SPEED RS232 OUTPUT ENABLE PRINT ( ME ) PRINT CONNECTION PRINT DATA PROCESS PRINT ALARM STATUS 8. DISPLAY 8.1 LANGUAGE 8.2 D.RATE 8.3 CONTRAST 8.4 CURRENCY 8.5 CUR. DECIM. 8.6 XXX/dm³ XXX/dm³ - ENGL, IT,FREN, SPAN. REFRESH DISPLAY SET CONTRAST SET E CURRENCY CONV. DECIMAL CURRENCY CONV. FACTOR + FLOW RATE CONV. FACTOR - FLOW RATE 9.DATA LOGGER 9.1 DD/MM/YY 00: ACQUISITION 9.3 INTERVAL 9.4 DISPLAY DATA 9.5 DISPLAY EVENTS 9.6 DISP MIN/MAX 9.7 CLEAR DATA 9.8 CLEAR EVENTS 9.9 RESET MIN/MAX DATE AND TIME SET AUTO DATA LOGIN INTERVAL DATA LOGING DISPLAING DATA STORED ALARM EVENTS ERASE DATA ERASE DATA ERASE ALARM EVENTS ERASE MIN/MAX FLOW RATE 10.DIAGNOSI 10.1 CALIBRATION 10.2 SELFTEST 10.3 SIMULATION ENABLES CALIBRATION METER AUTOTEST FLOW RATE SIMULATION 11.INTERNAL DATA 11.1 L2 KEYCODE 11.2 LOCK LEVEL 11.3 LOAD FACT. PRES LOAD USER PRES SAVE USER PRES HOURS 11.7 KS LIVELL 2 ACCESS CODE LOCK LEVEL SET FACTORY VALUE RECALL USER VALUE RECALL USER VALUE SAVE OPERATION TIME SET KS 12 BATCH 12.1 N. SAMPLES 12.2 DIFF.THR 12.3 V.COM 12.4 V.PRE 12.5 AUTO BATCH 12.6 BM AUTO SEL 12.7 CONS. MODE SAM. BATCH FOR V. COM. % LIMIT Of COMP. VALUE COMPENSATION VALUE PRE-BATCH VALUE ENABLE AUTO BATCH FORMULA AUTO-SEL. CONSENT START BATCH Revisione N 1 15/10/03 AGGIUNTO DIMENSIONI D INGOMBRO
6 SPECIFICA TECNICA Data Documento 15/10/03 Pagine 6/7 STO82 02 DATA SHEET ML CONNESSIONI ELETTRICHE /ELECTRICAL CONNECTIONS VERSIONE COMPATTA/SEPARATA - COMPACT/SEPARATE VERSION ELETTRODI INPUT RS mA E1 E2 C SC + - B A + - OUT 3 RS 232 E C CTS RD TD SG SC B1 B2 BOBINE SC + CE E 24V OUT1 C E OUT2-24V - + INP2 E C OUT 4 SC mA VERSIONE QUADRO / PANEL VERSION Morsettiera M2 Morsettiera M1 OUT 4 C NC NO OUT 3 C NC NO 24V - OUT2 OUT1 24V BOBINE E C E CE + SC B2 B1 SC Mors. M SC mA A RS485 B + - INPUT SC C E2 ELETTRODI E1 STANDARD DIGITAL OUT HIGH FREQUENCY DIGITAL OUT ( OPT. ) STANDARD ANALOG OUT +24V INTERNAL I ma 9 (+) 0/4..20mA OUT STANDARD DIGITAL INPUT 10 K 10 (+) 5/33 Vdc (ON) 0/1,5 Vdc (OFF) 9 (-) 24V COMMON 10 (-) Revisione N 1 15/10/03 AGGIUNTO DIMENSIONI D INGOMBRO
7 LOCK SPECIFICA TECNICA Data Documento 15/10/03 Pagine 7/7 STO82 02 DATA SHEET ML COME ORDINARE / HOW ORDER Morsettiera M3 Terminal block M >HV< VAC >LV< VAC VDC >LLV< VDC Morsettiera M1 Terminal block M1 Morsettiera M2 Terminal block M2 VERSIONE COMPATTA COMPACT VERSION VERSIONE A PARETE WALL VERSION VERSIONE A QUADRO PANEL VERSION ML 210 Display A Versione cieca senza display e tastiera di programmazione / Blind version without display and keyboard B Versione con display grafico LCD WSTN a matrice a punti 128 x 64, da 8 righe per 16 caratteri / Graphic LCD WSTN back light display execution, point matrix 128 x 64, 8 line each of (retroilluminato a LED) con tastiera di programmazione ( a 3 tasti) 16 characters and 3 programming keys Materiale custodia convertitore - Classe di protezione / Housing material - Protection rate 0 Custodia in Alluminio pressofuso Verniciata colore RAL6028, classe di protezione IP67 / Painted aluminum die casting (painted RAL6028),protection rate IP67 1 Custodia in Aisi 304 Elettrolucidato / Aisi 304 Electro-polish 2 NORYL UL 94 V-0 autoestinguente NERO ( SOLO VERSIONE F ) IP 54 / NORYL UL 94 V-0 black ( ONLY "F" VERSION ) IP 54 3 NORYL UL 94 V-0 autoestinguente NERO ( SOLO VERSIONE F ) + Coperchio frontale trasparente IP 65 / NORYL UL 94 V-0 BLACK ( ONLY "F" VERSION )+TRANSPARENT FRONTAL COVER IP 65 Versione / Version A Versione compatta, con sensore MS... (massima temperatura del liquido 100 C) Compact version with sensor MS... (liquid maximum temperature 100 C) B Esecuzione separata da campo per accoppiamento a sensori MS..., completa Separate version for wall monting, complete with mounting accessories di accessori di montaggio, in Acciaio Carbonio (verniciato RAL6028) in Carbon Steel (painted RAL6028) F Esecuzione separata per montaggio a incasso ( a quadro ) secondo DIN 43700, Separate version for front panel mounting according DIN 43700, per accoppiamento a sensori MS..., dimensioni 72 x 144 complete with mounting accessories, dimensions 72 x 144 mm Alimentazione / / Power supply 1 Alimentazione : V 45/66 Hz Power supply : V 45/66 Hz 2 Alimentazione : V dc / V ac Hz Power supply : V dc / V ac Hz 3 Alimentazione : V dc Power supply : V dc 9 Alimentazione : altre Power supply : other Uscita analogica / Analogue / output A Senza uscita analogica 0/4 20/22 ma Without Analogue output 0/4...20/22 ma B Uscita analogica 0/4 20/22 ma Analogue output 0/4...20/22 ma Interfaccia Seriale / Serial Interface 1 Senza Interfaccia Seriale Without Serial Interface 2 Interfaccia Seriale RS485 RS485 Serial Interface Moduli aggiuntivi / Additional module A Senza opzioni Without additional module C ME200; n. 2 uscite on/off programmabili ME200; n. 2 additional ON / OFF programmable output D ME201; n. 2 uscite on/off programmabili (delle quali 1 a alta frequenza 10 KHz) ME201; n. 2 additional ON / OFF programmable output (one of them at 10 KHz frequency) E ME202; 2a uscita 0/4 20 ma + n.2 uscite on/off programmabili ME202; additionals 0/4 20 ma + n.2 ON / OFF programmable output F ME203;n.1 porta RS n. 2 uscite on/off programmabili ME203; n. 1 RS232 serial interface + n.2 additional ON / OFF programmable output, 2A - 60 Vca, 60W 125 VA) G ME204;n.1 porta RS n. 2 uscite on/off programmabili + 2a uscita 0/4 20 ma ME204; n. 1 RS232 serial interface + additionals 0/4 20 ma + n.2 ON / OFF program. output Vca, 60W 125 VA) P ME205; n. 2 uscite a relè(ognuna con 1 contatto NO+1contattoNC,2A-60Vca,60W 125 VA) ME205; n. 2 relè output (each with 1 NO contact + 1 NC contact, 2A - 60 Vca, 60W 125 VA) T ME207; n. 2 uscite a relè (ognuna con 1 contatto NO+1contattoNC, 2A- 250Vca,60W 125 VA) ME207; n. 2 relè output (each with 1 NO contact + 1 NC contact, 2A Vca, 60W 125 VA) H ME 100 : modulo Profibus DP ME 100 : Profibus DP module M ME 220 : d. logger r. t. c. ; 128K record : portata;totaliiz+/-; data/ora ) N ME 221 : d. logger r. t. c. ; 128 Krecord : port.;tot.+/-; data/ora ; n 1 RS 232, n 1 RS 485 O ME 221 : d. logger r. t. c. ; 128K record : port.;tot.+/-; data/ora ; n 1 RS 232, n 1 RS A.I. Z Altro ME 220 : d. logger r. t. c. ; 128K record : F.R. ;tot.+/-; date/time ) ME 221 : d. logger r. t. c. ; 128 Krecord : F.R.;tot.+/-; date/time ; n 1 RS 232, n 1 RS 485 ME 221 : d. logger r. t. c. ; 128K record : F.R.;tot.+/-; date/time ; n 1 RS 232, n 1 RS A.I. Other ML 210 B 0 A 1 B 2 A ESEMPIO DI CODICE PER L'ORDINE/ EXAMPLE OF CODE FOR ORDER ATTENZIONE/WARNING I DATI POSSONO CAMBIARE SENZA ALCUN PREAVVISO/THE ABOVE DATA CAN BE CHANGED WITHOUT NOTICE Revisione N 1 15/10/03 AGGIUNTO DIMENSIONI D INGOMBRO
8 M I S U R A T O R I E L E T T R O M A G N E T I C I D I P O R T A T A S E R I E E L E C T R O M A G N E T I C F L O W M E T E R S E R I E S ISOMAG Millennium SENSOR MODEL MS 2500 gamma di diametri a disposizione. gamma di diametri a disposizione. SENSORE FLANGIATO : LA PIU AMPIA GAMMA DI DIAMETRI DELLA SERIE Millennium, DISPONIBILE CON UNA VASTA GAMMA DI FLANGE FLANGED SENSOR : THE WIDEST SELECTIONS OF DIAMETERS OF Millennium SERIE'S; AVAILABLE FOR WIDE TYPE OF FLANGES MS 2500 VERSIONE SEPARATA MS 2500 SEPARATE VERSION
9 SPECIFICA TECNICA Data Documento 15/10/03 Pagine 2/6 STO50 02 DATA SHEET MS /10/03 15/10/03 DATI TECNICI / TECHNICAL DATA Materiale corpo Body material Diametri nominali Nominal diameter Pressione nominale Nominal pressure Attacchi al processo Process connection Materiale flange Flanges material Temperatura liquido Liquid temperature Resistenza al vuoto Vacuum resistance Materiale rivestimento Lining material Materiale guarnizioni Gasket material Materiale elettrodi Electrode material Versioni Classe di protezione Version protection rate Precisione Accuracy Acciaio al carbonio verniciato / Carbon steel painted Acciaio inox AISI 304/316 (opzionale) / Stainless steel AISI 304/316 (optional) DN PN 16 Altre a richiesta / Other on request Flange: UNI, ANSI, DIN, JIS Altre a richiesta / Other on request Acciaio al carbonio / Carbon steel Acciaio inox AISI 304 -AISI 316 (opzionale) / Stainless steel AISI 304- AISI316 (op.) 0 C 60 C con rivestimento in PP / 32 F 140 F with pp lining -5 C 80 C con rivestimento in Ebanite / -23 F 176 F with ebanite lining -20 C 100 C con rivestimento in PTFE versione compatto / -4 F 212 F with PTFE lining in compact version -20 C 150 C con rivestimento in PTFE versione separata / -4 F 302 F with PTFE lining in separate version 20 Kpa a 100 C / 20 Kpa at 100 C Polipropilene / Polyipropylen ( max. PN 16/ max. PN 16 ) Ebanite / Ebonite PTFE Altri a richiesta / Other on request Senza guarnizioni vers. Lininig PTFE-EBNITE/without gasket with lining PTFE-EBNITE FPM con lining in Polipropilene / FPM with lining in Polyipropylen Acciaio Inox AISI 316L / Stainleseel AISI 316 Hastelloy B o C Platino-rodio / platinum-rhodium Titanio / Titanium Tantalio / Tantalum Altri a richiesta / Other on request Compatta IP 67 / Compact version IP 67 Separata (massimo 20m) IP 68 / Separate version (max 20m) IP 68 Separata (massimo 500m) con pre-amplificatore IP 67 (IP 68 opzionale) separate version (max 500 mt), with preamplifier IP 67 (OPT. IP 68) Vedi tabella sotto / see table below Revisione N 1
10 SPECIFICA TECNICA Data Documento 15/10/03 Pagine 3/6 STO50 02 DATA SHEET MS /10/03 15/10/03 DIMENSIONI D INGOMBRO / OVERALL DIMENSIONS 100 D H L Revisione N 1
11 SPECIFICA TECNICA Data Documento 15/10/03 Pagine 4/6 STO50 02 DATA SHEET MS /10/03 15/10/03 DIMENSIONS mm (inches) DN 25 (1") 32 (1"1/4) 40 (1"1/2) 50 (2") 65 (2"1/2 ) 80 (3") 100 (4") 125 (5") 150 (6") 200 (8") 250 (10) 300 (12") 350 (14") 400 (16") 450 (18") 500 (20") 600 (24") 650 (26") 700 (28") 750 (30") 800 (31") 850 (34") 900 (36") 1000 (42") 1200 (47") MS 2500 PN 10 / 64 - ANSI 150/300 OVERALL DIMENSIONS PN PN 10 PN 16 PN 25 PN 40 PN 64 ANSI 150 ANSI 300 L 200 (7.87) 200 (7.87) 200 (7.87) 200 (7.87) 200 (7.87) 200 (7.87) 200 (7.87) H 185 (7.28) 185 (7.28) 185 (7.28) 185 (7.28) 198 (7.80) 181 (7.13) 190 (7.48) D 115 (4.53) 115 (4.53) 115 (4.53) 115 (4.53) 140 (5.51) 108 (4.25) 124 (4.88) L 200 (7.87) 200 (7.87) 200 (7.87) 200 (7.87) 200 (7.87) 200 (7.87) 200 (7.87) H 203 (8) 203 (8) 203 (8) 203 (8) 209 (8.23) 192 (7.56) 199 (7.83) D 140 (5.51) 140 (5.51) 140 (5.51) 140 (5.51) 155 (6.10) 118 (4.65) 133 (5.24) L 200 (7.87) 200 (7.87) 200 (7.87) 200 (7.87) 200 (7.87) 200 (7.87) 200 (7.87) H 213 (8.39) 213 (8.39) 213 (8.39) 213 (8.39) 220 (8.66) 207 (8.15) 221 (8.7) D 150 (5.90) 150 (5.90) 150 (5.90) 150 (5.90) 170 (6.69) 127 (5) 156 (6.14) L 200 (7.87) 200 (7.87) 200 (7.87) 200 (7.87) 200 (7.87) 200 (7.87) 200 (7.87) H 228 (8.98) 228 (8.98) 228 (8.98) 228 (8.98) 233 (9.17) 222 (8.74) 228 (8.98) D 165 (6.50) 165 (6.50) 165 (6.50) 165 (6.50) 180 (7.09) 152 (5.98) 165 (6.5) L 200 (7.87) 200 (7.87) 200 (7.87) 200 (7.87) 200 (7.87) 200 (7.87) 200 (7.87) H 248 (9.76) 248 (9.76) 248 (9.76) 248 (9.76) 257 (10.12) 245 (9.65) 251 (9.88) D 185 (7.28) 185 (7.28) 185 (7.28) 185 (7.28) 205 (8.07) 178 (7.01) 191 (7.52) L 200 (7.87) 200 (7.87) 200 (7.87) 200 (7.87) 200 (7.87) 200 (7.87) 200 (7.87) H 263 (10.35) 263 (10.35) 263 (10.35) 263 (10.35) 267 (10.51) 259 (10.2) 268 (10.55) D 200 (7.87) 200 (7.87) 200 (7.87) 200 (7.87) 215 (8.46) 191 (7.52) 210 (8.27) L 250 (9.84) 250 (9.84) 250 (9.84) 250 (9.84) 250 (9.84) 250 (9.84) 250 (9.84) H 283 (11.14) 283 (11.14) 294 (11.57) 294 (11.57) 297 (11.69) 288 (11.34) 300 (11.81) D 220 (8.66) 220 (8.66) 235 (9.25) 235 (9.25) 250 (9.84) 229 (9.02) 254 (10) L 250 (9.84) 250 (9.84) 250 (9.84) 250 (9.84) 250 (9.84) 250 (9.84) 250 (9.84) H 313 (12.32) 313 (12.32) 325 (12.80) 325 (12.80) 330 (13) 315 (12.4) 328 (12.91) D 250 (9.84) 250 (9.84) 270 (10.63) 270 (10.63) 295 (11.61) 254 (10) 279 (10.98) L 300 (11.81) 300 (11.81) 300 (11.81) 300 (11.81) 300 (11.81) 300 (11.81) 300 (11.81) H 344 (13.54) 344 (13.54) 355 (13.98) 355 (13.98) 377 (14.84) 341 (13.43) 360 (14.17) D 285 (11.22) 285 (11.22) 300 (11.81) 300 (11.81) 345 (13.58) 279 (10.98) 318 (12.52) L 350 (13.78) 350 (13.78) 350 (13.78) 350 (13.78) 350 (13.78) 350 (13.78) 350 (13.78) H 399 (15.71) 399 (15.71) 415 (16.34) 425 (16.73) 435 (17.13) 401 (15.79) 420 (16.54) D 340 (13.39) 340 (13.39) 360 (14.17) 375 (14.76) 415 (16.34) 343 (13.5) 381 (15) L 450 (17.72) 450 (17.72) 450 (17.72) 450 (17.72) 450 (17.72) 450 (17.72) 450 (17.72) H 454 (17.87) 460 (18.11) 475 (18.7) 493 (19.41) 491 (19.33) 461 (18.15) 480 (18.9) D 395 (15.55) 405 (15.94) 425 (16.73) 450 (17.72) 470 (18.5) 406 (15.98) 445 (17.52) L 500 (19.69) 500 (19.69) 500 (19.69) 500 (19.69) 500 (19.69) 500 (19.69) 500 (19.69) H 504 (19.84) 515 (20.28) 535 (21.06) 558 (21.97) 545 (21.46) 527 (20.75) 546 (21.5) D 445 (17.52) 460 (18.11) 485 (19.09) 515 (20.28) 530 (20.87) 483 (19.02) 521 (20.51) L 550 (21.65) 550 (21.65) 550 (21.65) 550 (21.65) 550 (21.65) 550 (21.65) 550 (21.65) H 564 (22.2) 575 (22.64) 598 (23.54) 619 (24.37) 603 (23.74) 582 (22.91) 607 (23.9) D 505 (19.88) 520 (20.47) 555 (21.85) 580 (22.83) 600 (23.62) 533 (20.98) 584 (22.99) L 600 (23.62) 600 (23.62) 600 (23.62) 600 (23.62) 600 (23.62) 600 (23.62) 600 (23.62) H 620 (24.41) 630 (24.8) 659 (25.94) 695 (27.36) 670 (26.38) 639 (25.16) 664 (26.14) D 565 (22.24) 580 (22.83) 62 (2.44) 660 (25.98) 670 (26.38) 597 (23.5) 648 (25.51) L 600 (23.62) 600 (23.62) 600 (23.62) 600 (23.62) 600 (23.62) 600 (23.62) H 670 (26.38) 690 (27.17) 709 (27.91) 720 (28.35) 688 (27.09) 726 (28.58) D 615 (24.21) 640 (25.2) 670 (26.38) 685 (26.97) 635 (25) 711 (27.99) L 600 (23.62) 600 (23.62) 600 (23.62) 600 (23.62) 600 (23.62) 600 (23.62) H 725 (28.54) 758 (29.84) 769 (30.28) 784 (30.87) 751 (29.57) 770 (30.31) D 670 (26.38) 715 (28.15) 730 (28.74) 755 (29.72) 699 (27.52) 775 (30.51) L 600 (23.62) 600 (23.62) 600 (23.62) 600 (23.62) 600 (23.62) 600 (23.62) H 830 (32.68) 879 (34.61) 880 (34.65) 911 (35.87) 866 (34.09) 916 (36.06) D 780 (30.71) 840 (33.07) 845 (33.27) 890 (35.04) 813 (32.01) 914 (35.98) L 650 (25.59) 650 (25.59) H 921 (36.26) 1002 (39.45) D 870 (34.25) 972 (38.27) L 700 (27.56) 700 (27.56) 700 (27.56) 700 (27.56) H 895 (35.24) 949 (37.36) 989 (38.94) 1016 (40) D 800 (31.5) 910 (35.83) 960 (37.8) 995 (39.17) L 750 (29.53) 750 (29.53) H 1032 (40.63) 1121 (44.13) D 984 (38.74) 1092 (42.99) L 800 (31.5) 800 (31.5) 800 (31.5) 800 (31.5) H 1058 (41.65) 1060 (41.73) 1106 (43.54) 1149 (45.24) D 1015 (39.96) 1025 (40.35) 1085 (42.72) 1114 (43.86) L 850 (33.46) 850 (33.46) H 1149 (45.24) 1230 (48.43) D 1111 (43.74) 1207 (47.52) L 900 (35.43) 900 (35.43) 900 (35.43) 900 (35.43) 900 (35.43) 900 (35.43) H 1158 (45.59) 1160 (45.67) 1206 (47.48) 1259 (49.57) 1206 (47.48) 1292 (50.87) D 1115 (43.9) 1125 (44.29) 1185 (46.65) 1250 (49.21) 1168 (45.98) 1270 (50) L 1000 (39.37) 1000 (39.37) 1000 (39.37) 1000 (39.37) 1000 (39.37) 1000 (39.37) H 1269 (49.96) 1284 (50.55) 1329 (52.32) 1369 (53.9) 1381 (54.37) 1467 (57.76) D 1230 (48.43) 1255 (49.41) 1320 (51.97) 1360 (53.54) 1346 (52.99) 1448 (57.01) L 1200 (47.24) 1200 (47.24) 1200 (47.24) 1200 (47.24) H 1490 (58.66) 1506 (59.29) 1539 (60.59) 1579 (62.17) D 1455 (57.28) 1485 (58.46) 1530 (60.24) 1575 (62.01) Revisione N 1
12 SPECIFICA TECNICA Data Documento 15/10/03 Pagine 5/6 STO50 02 DATA SHEET MS /10/03 15/10/03 TABELLA DELLE PRECISIONI/ACCURACY TABLE CONVERTITORI ML 190 ML 200 ML 201 ML 202 ML 191 ML 210 ML 211 ML 212 ML 3F1 ML 110 STANDARD MS /- 0,4% v.l,/r.v. +/- 0,4% v.l,/r.v. +/- 0,8% v.l,/r.v. OPTIONAL +/- 0,4% v.l,/r.v. Ripetibilità * /Ripetibility* : +/- 0,1% *ML110 : +/- 0,2% Condizioni di riferimento per la definizione della precisione dello strumento Reference condition for accuracy definition Temperatura acqua/water temperature : 20 C Temperatura ambiente/ambient temperature : 25 C Tempo di prova/ test time : > 60 sec. Warm-up convertitore/converter warm-up : > 60 Portata costante durante il test/ constant flow rate during the test Pressione/Pressure : 50 Kpa Velocità del liquido/speed of liquid > 1m/s Revisione N 1
13 SPECIFICA TECNICA Data Documento 15/10/03 Pagine 6/6 STO50 02 DATA SHEET MS /10/03 15/10/03 COME ORDINARE / HOW ORDER Compatta/Compact Separata/Separate Separata con preamplificatore Separate with preamplifer max 20mt max 500mt D INSIDE O-RING MS 2500 Diametro nominale, flange UNI (ANSI) / Rivestimento / Temperatura / Campo di misura / Nominal Diameter / Lining / Liquid temperature / Measuring range T25 T1200 Da DN25 (1") a DN 1200 (48"), tubo di misura in PTFE, massima temperatura del liquido 150 C, Campo di misura 0...0,72/ m3/h / From ND 25 (1") up to ND 1200 (48"), PTFE lining, liquid maximum temperature 150 C, Measuring range 0...0,72/ m3/h P25 P150 Da DN25 (1") a DN 150 (6"), tubo di misura in polipropilene, massima temperatura del liquido 60 C, Campo di misura 0...0,72/ m3/h / From ND 25 (1") up to ND 150 (6"), Polypropilene lining, liquid maximum temperature 60 C, Measuring range 0...0,72/ m3/h E200 E400 Da DN200 (8") a DN 2000 (80"), tubo di misura in ebanite, massima temperatura del liquido 80 C, Campo di misura ,2/ m3/h / From ND 200 (8") up to ND 2000 (80"), Ebonite lining, liquid maximum temperature 80 C, Measuring range ,2/ m3/h Materiale guarnizioni per tenute interne (solo per rivestimento in polipropilene) / Gasket material (internal tightness, only for polypropilene lining)) A B C Nessun O-Ring ( solo per rivestimento in PTFE/EBANITE) / No O-Ring ( ONLY FOR PTFE/EBANITE LINING ) O-Ring : FPM O-Ring : Epdm Z O-Ring : da specificare / other O-Ring Tipo flange / Flanges type 1 Flange UNI2223 PN16 ( max. con rivestimento in Polipropilene) Flanges UNI2223 PN16 (max. with Polypropilene lining) 2 Flange UNI2223 PN10 Flanges UNI2223 PN10 3 Flange UNI2223 PN25 Flanges UNI2223 PN25 4 Flange UNI2223 PN40 ( standard per DN in PTFE ) Flanges UNI2223 PN40 ( standard for DN with PTFE lining) 5 Flange UNI2223 PN64 Flanges UNI2223 PN64 6 Flange ANSI 150RF Flanges ANSI 150RF Flange ANSI 300RF Flange PN6 Flange JIS 10K Flange: da specificare Flanges ANSI 300RF Flanges PN6 Flanges JIS 10K Flanges: to be specified Materiale corpo e flange / Body material A Materiale corpo e flange : Acc. Carb., verniciato RAL6028 Body and flange in Carbon Steel, RAL6028 painted B Materiale corpo e flange : AISI304 (solo con lining in PTFE) Body and flange in Stainless Steel (AISI304), only with PTFE lining C Materiale corpo e flange : AISI316 (solo con lining in PTFE) Body and flange in Stainless Steel (AISI316), only with PTFE lining Z Materiale corpo e flange : da specificare Body and flange material: other Numero e materiale elettrodi / Number and electrodes material 1 n. 2 elettrodi in AISI316 L (2 di misura ) n. 2 measure electrodes in AISI316 2 n. 3 elettrodi in AISI316 (2 di misura + 1 di massa) n. 3 (2 measure + 1 for ground) electrodes in AISI316 4 n. 3 elettrodi in Hastelloy C 276 (2 di misura + 1 di massa) n. 3 (2 measure + 1 for ground) electrodes in Hastelloy C 5 n. 3 elettrodi in Titanio (2 di misura + 1 di massa) n. 3 (2 measure + 1 for ground) electrodes in Titanium 6 n. 3 elettrodi in Tantalio (2 di misura + 1 di massa), non possibile con Polipropilene n. 3 (2 measure + 1 for ground) electrodes in Tantalum; not available with Polypropilene 7 n. 3 elettrodi in Platino-Rhodio 90/10 (2 di misura + 1 di massa), non possibile con Polipropilene n. 3 (2 measure + 1 for ground) electrodes in Platinum; not available with Polypropilene 0 da specificare/other Versione - Classe di protezione / Execution - Protection rate Versione compatta, classe di protezione IP67, A massima temp. del liquido 100 C B C D Versione separata C (massima distanza 10 (20*) m., massima temperatura del liquido 150 C, classe di protezione IP68 Versione separata L (in acc. carb.), completa di preamplificatore (massima distanza 500 m), massima temperatura del liquido 150 C Versione separata L (in AISI 304), completa di preamplificatore (massima distanza 500 m), massima temperatura del liquido 150 C Compact execution, IP67 protection rate, liquid maximum temperature 100 C Separate execution "C", maximum length 10 m (20m, see note 1), liquid maximum temperature 150 C, protection rate IP68 Separate execution "L" (in Carbon Steel), with preamplifier (maximum length 500 m), liquid maximum temperature 100 C, protection rate IP67 Separate execution "L" (in AISI304), with preamplifier (maximum length 500 m.), liquid maximum temperature 100 C, protection rate IP67 MS 2500 T25 A 4 A 1 A ESEMPIO DI CODICE PER L'ORDINE/ EXAMPLE OF CODE FOR ORDER ATTENZIONE/WARNING I DATI POSSONO CAMBIARE SENZA ALCUN PREAVVISO/THE ABOVE DATA CAN BE CHANGED WITHOUT NOTICE Revisione N 1
ISOMAG Millennium ML 210 A QUADRO 210 PANEL MOUNTING VERSION ML 210 VERSIONE A PARETE ML 210 WALL VERSION
M I S U R A T O R I E L E T T R O M A G N E T I C I D I P O R T A T A S E R I E E L E C T R O M A G N E T I C F L O W M E T E R S E R I E S ISOMAG Millennium CONVERTER MODEL M L 2 1 0 CONVERTITORE PER
More informationCONVERTITORE ECONOMICO PER MISURATORE ELETTROMAGNETICO DI PORTATA LOW COST CONVERTER FOR ELECTROMAGNETIC FLOW METER
M I S U R A T O R I E L E T T R O M A G N E T I C I D I P O R T A T A S E R I E E L E C T R O M A G N E T I C F L O W M E T E R S E R I E S ISOMAG Millennium CONVERTER MODEL M L 1 1 0 CONVERTITORE ECONOMICO
More informationISOMAG UNIQUE PID REGULATOR + MAG CONVERTER THE FRIENDLY MAG METER
UNIQUE PID REGULATOR MAG CONVERTER ISOMAG THE FRIENDLY MAG METER CONVERTER ML 212 Integrate PID Regulator N 1 output (0/4 20mA; frequency; pulses variable duty cycle ) for the actuator N 2 inputs (0 5/10V
More informationFAST SAMPLING CONVERTER
FAST SAMPLING CONVERTER ML4-F1 HIGH SAMPLING RATE CONVERTER (UP TO 400 SAMPLES/SECOND) Warranty conditions are available on this website: www.isomag.eu only in English version INDEX TECHNICAL DATA... 3
More information( F L O W I Z F A M I L Y )
THE MOST ACCURATE BATTERY POWERED SYSTEM ( F L O W I Z F A M I L Y ) E l e c t r o m a g n e t i c c o n v e r t e r p o w e r e d b y b a t t e r i e s, s o l a r p a n e l o r D C p o w e r w i t h 4
More informationWarranty conditions are available on this website: only in English version
THE MOST ACCURATE BATTERY POWERED SYSTEM FLOWIZ ( M L 2 5 2 ) C O N V E R T E R W I T H B A T T E R Y S U P P L Y Warranty conditions are available on this website: www.isomag.eu only in English version
More informationTU SERIES. SENSORI ULTRASONICI M30 - SERIE TU TU series - M30 ultrasonic SENSORS TU 1 / C 0-0 E
SENSORI ULTRASONICI M - SERIE TU TU series - M ultrasonic SENSORS Sensori ultrasonici M serie TU M ultrasonic sensors TU series b Caratteristiche principali Main features > Modelli con uscita digitale
More informationFLOWIZ ( M L ) Warranty conditions are available on this website: only in English version
THE MOST ACCURATE BATTERY POWERED SYSTEM FLOWIZ ( M L 2 5 5 ) E l e c t r o m a g n e t i c c o n v e r t e r p o w e r e d b y b a t t e r i e s a n d u n i v e r s a l p o w e r s u p p l y. O p t i
More informationMS 5000 CIAO SENSOR EXTREMELY EASY TO INSTALL THANKS TO PATENTED WRAPPER FIXING SYSTEM
CIAO SENSOR MS 5000 EXTREMELY EASY TO INSTALL THANKS TO PATENTED WRAPPER FIXING SYSTEM Warranty conditions are available on this website: www.isomag.eu only in English version INDEX TECHNICAL DATA... 3
More informationS103C ELECTROMAGNETIC FLOW METERS. Main application fields MOUNTING
ELECTROMAGNETIC FLOW METERS The electromagnetic flow meter is used to measure the flow rate of conductive fluids and waste water. The measurement is independent of the density, viscosity, temperature and
More informationElectro-Magnetic Flowmeters COPA-XE
Data Sheet Electro-Magnetic Flowmeters COPA-XE 10DX4311 Flowmeter system utilizes a smart microprocessor converter System accuracy of ± 0.5% of rate Field configurable via integral pushbuttons, eliminates
More informationISOIL ML210 CONVERTER For use with ELECTROMAGNETIC FLOWMETERS
ISOIL ML210 CONVERTER For use with ELECTROMAGNETIC FLOWMETERS 1 2 ML210 CONVERTER MANUAL Including Installation Instructions for M/MS SERIES ELECTROMAGNETIC FLOWMETERS April 2005 VER 3.0x ML 210 - Version
More informationE l e c t r o m a g n e t i c f l o w m e t e r s
E l e c t r o m a g n e t i c f l o w m e t e r s P r o v e n A N D R e l i a b l e F l o w M e a s u r e m e n t 2 MJK MagFlux flow meters combine high accuracy, stability and low maintenance. Without
More informationMagnetic-inductive flow meter. PITe / UMF2. Technical Datasheet. Maintenance-free Nearly no pressure drop Robust design Easy installation and start-up
Magnetic-inductive flow meter Technical Datasheet PITe / UMF2 Maintenance-free Nearly no pressure drop Robust design Easy installation and start-up Subject to change without notice 1 Function An electrically
More informationFlow Measurement SITRANS F M
Overview Mode of operation The flow measuring principle is based on Faraday s law of electromagnetic induction according to which the sensor converts the flow into an electrical voltage proportional to
More informationAmbient Conditions. Operating Conditions. Pressure
Temperature Relative Humidity -20 C +75 C 0% 100 RH to 65 C non condensing 86 106 bar 4.0MPa (DN10 DN80) 1.6MPa (DN100 DN150) 1.0MPa (DN200 DN1000) Remote version < 80 C (rubber coating) Compact version
More informationKFS. Flap-type flow meter. Design and range of application
Design and range of application The measuring device operates largely independent of viscosity and is suitable for indicating the flow rate of water, acids, alkaline solutions and gases. Every device is
More informationELETTRONICA DUE. Serie / Series C - 3X Contaimpulsi bidirezionali multifunzione DIN 72X72 DIN 72X72 µ Processor Multifunction up / down counter FOTEK
* Microprocessore < µp > / Micro - Processor < µp> based. * Memoria : EEPROM / Memory method : EEPROM * Alta risposta di frequenza : 5KHz / High response frequency : 5Khz * Alta affidabilità con circuito
More informationmass flowmeter for compressed air
mass flowmeter for compressed air VARIOMASS MF High End electronic for air measurement & analyse - 1 - The VARIOMASS flow meter for compressed air is a comfortable system for air mass flow measurement,
More informationSITRANS F flowmeters SITRANS F US. Transmitter FUS060. Overview
Overview Function Displays and keypad Operation of the SITRANS FUS060 transmitter can be carried out using: Keypad and display unit HART communicator PC/laptop and SIMATIC PDM software via HART communication
More informationSITRANS F flowmeters. SITRANS F M System information MAGFLO electromagnetic flowmeters 4/11
Overview family are designed for measuring the flow of electrically conductive mediums. Benefits System information FLO Easier to commission for 5000, 6000, 6000 I All FLO pulsed DC feature a unique SENSORPROM
More informationFlow Measurement SITRANS F M
Overview Mode of operation The flow measuring principle is based on Faraday s law of electromagnetic induction according to which the sensor converts the flow into an electrical voltage proportional to
More informationUSER MANUAL 2AMIN514VPBS
USER MANUAL 2AMIN514VPBS SUBJECT INDEX: DESCRIPTION TECHNICAL SPECIFICATION PUSH OPERATION BLUETOOTH MODE + PUSH Necto Group S.r.l. 35127 Padova - Via Canada, 8 - ITALY - T +39 049 8791001 F +39 049 8791002
More informationDesign and applications
Design and applications The measuring device operates largely independent of viscosity and is suitable for indicating the flow rate of water, acids, alkaline solutions and gases. Every device is calibrated
More informationSITRANS F flowmeters SITRANS F M. Transmitter Transmag 2 with sensor 911/E 4/77. Overview
Overview Design The complete flowmeter consists of a flow sensor and an associated transmitter from the Transmag 2 for pulsed alternating field. These are available as remote and compact versions ( 911/E
More informationSITRANS F flowmeters SITRANS F M. Flow sensor MAG /48 Siemens FI Overview
Siemens AG 2009 Overview Integration The complete flowmeter consists of a flow sensor and an associated transmitter MAG 5000, 6000 or 6000 I. The flexible communication concept USM II simplifies integration
More informationFLOMID FX Electromagnetic Flowmeter
FLOMID FX Electromagnetic Flowmeter Working pressure manufacturing according to PED 97/23/CE (Lloyd s Register Certificate Nº 031) Introduction Modular design in two versions: Compact, sensor and electronics
More informationJ Series induq VMZ MAGNETIC INDUCTIVE FLOW SENSORS. DB_Magnetic_Inductive_Flow_Sensors 05/2016
J Series induq VMM J Series induq VMI J Series induq VMZ MAGNETIC INDUCTIVE FLOW SENSORS J DB_Magnetic_Inductive_Flow_Sensors 5/216 67 Magnetic inductive flow sensors Principle of operation The smart flow
More information4/11. Overview. Easier service Transmitter replacement requires no programming. SENSORPROM automatically updates all settings after initialization.
Overview family are designed for measuring the flow of electrically conductive mediums. Benefits Easier commissioning of 5000, 6000, 6000 I All pulsed DC feature a unique SENSORPROM memory unit which stores
More informationFlow Measurement SITRANS F M. Flow sensor MAG /49. Overview
Siemens AG 2010 Flow Measurement Overview Mode of operation The flow measuring principle is based on Faraday s law of electromagnetic induction according to which the sensor converts the flow into an electrical
More informationCoriolis Massflowmeter
Coriolis Massflowmeter for liquids and gas measuring monitoring analysing Measuring range: 0-0.8 kg / h 0-65 000 kg / h water Accuracy: ± 0.1 of reading ±zero-point stability (liquids) pmax: PN40 tmax:
More informationEN-2018 MAGNETIC FLOW METERS
EN-2018 MAGNETIC FLOW METERS www.meatest.com 1 MEASURING PRINCIPLE Having no moving or mechanical parts in the flow profile electromagnetic flow meters cause no pressure drop, are virtually maintenance
More informationDigital conductivity transmitter
Digital conductivity transmitter Compact version with integrated conductivity electrodes Remote version with seperated transmitter for short (15 ft.) or long (1500 ft.) distance Commissioning is easy due
More informationSistema di connessione LED Chip Array / LED Chip array connection system
Sistema di connessione LED Chip Array / LED Chip array connection system Cod. 034170 CONNETTORE LED BRIDGELUX ES ARRAY 25,8X22,8MM BIANCO Dimensioni chip array Chip array dimension Materiale corpo Body
More informationMagFlux ELECTROMAGNETIC FLOWMETERS BROCHURE EN 3.05 MAGFLUX BROCHURE 1401
MagFlux ELECTROMAGNETIC FLOWMETERS BROCHURE EN 3.05 MAGFLUX BROCHURE 1401 P R O V E N A N D R E L I A B L E F L O W M E A S U R E M E N T 2 MJK MagFlux flow meters combine high accuracy, stability and
More informationElectromagnetic Flow Transmitter
Electromagnetic Flow Transmitter Sensor in solid state technology Working as a transmitter and/or as an On/Off controller Automatic-calibration of full scale: Teach-In Clean in place (CIP) Type can be
More informationOPTIFLUX 5000 Technical Datasheet
OPTIFLUX 5000 Technical Datasheet Electromagnetic flowmeter in flanged version Exceptional long-term stability and accuracy For highly aggressive and abrasive fluids Fully vacuum-resistant with high-tech
More informationCERTIFIED SENSOR "SANITARY". SPECIFIC FOR THE USE IN ALIMENTARY
SNITRY SENSOR MS 2410 CERTIFIE SENSOR "SNITRY". SPECIFIC FOR THE USE IN IMENTRY N PHRMCEUTIC PPICTIONS Warranty conditions are available on this website: www.isomag.eu only in English version INEX TECHNIC
More informationwww. otech.com.sg EFS801 ELECTROMAGNETIC FLOWMETER
www. otech.com.sg EFS801 ELECTROMAGNETIC FLOWMETER 1 www. otech.com.sg EFS801 - CFT181/RFT201 ELECTROMAGNETIC FLOWMETER Accurate, Reliable and Stable Flow Measurement. Measuring Principle The measuring
More informationCONNETTORI SERIE VCM \ VCM SERIES CONNECTORS
3 CONNTTORI, PRSSACAVI ACCSSORI VALCOM CONNTTORI SRI VCM \ VCM SRIS CONNCTORS I Connettori Valcom VCM sono due serie di connettori progettati per soddisfare le esigenze operative della Direttiva ATX. Sebbene
More informationCoriolis Massflowmeter
Coriolis Massflowmeter for liquids and gas measuring monitoring analysing Measuring range: 0-60 kg/h 0-60 000 kg/h water Accuracy: ±0,15 of reading ±zero-point stability pmax: PN40 tmax: -40 +180 C Connection:
More informationType PLC Fitting. Valve for Continuous control. Diaphragm valve. Output
Digital Inductive conductivity transmitter Optimal solution for conductivity measurements in difficult fluids (polluted, dirty,...) PEEK/PPA version for CIP applications Large range of process connections
More informationMillenium ML110 CONVERTER OPERATING & INSTALLATION MANUAL
Millenium ML110 CONVERTER OPERATING & INSTALLATION MANUAL FLOMOTION SYSTEMS, Inc. 586 N. French Rd., Suite 6 Buffalo, NY 14228-2103 Toll Free: 800.909.FLOW (3569) (USA & Canada only) Phone: 716.691.3941
More informationTMU. Coriolis Mass Flow Meter. for liquids and gas
Coriolis Mass Flow Meter for liquids and gas measuring monitoring analysing TMU S5 OO Measuring range: 0-60 kg/h 0-2200 t/h water OO Accuracy: ± 0.1% of reading ±zero point stability (from liquids up to
More informationKMS305W. ManuFlo Page 1 MANU ELECTRONICS PTY LTD Flow Measurement Products. Electromagnetic Wafer Flowmeters with S300 display
Electromagnetic Wafer Flowmeters with S300 display for corrosive chemicals/acids & slurries (sizes: 2.5mm to 100mm) 0BFEATURES: For aggressive chemicals, slurries, oxides, grouts & dosing applications
More informationTEK-TEMP 2100A. Explosion-Proof Temperature Transmitter. TEMPERATURE. Technology Solutions
Technology Solutions TEK-TEMP 2100A Explosion-Proof Temperature Transmitter TEMPERATURE www.tek-trol.com Flow Level Temperature Pressure Valves Analyzers Accessories TekValSys Introduction Tek-Trol s Explosion-Proof
More informationKMS101W. ManuFlo Page 1 MANU ELECTRONICS PTY LTD Flow Measurement Products. Electromagnetic Wafer Flowmeters with S100 display
KMS101W Electromagnetic Wafer Flowmeters with S100 display ideal as resettable/batching meter (sizes: 15mm to 150mm) 0BFEATURES For ADMIXTURE Batching, Shotcrete, Mild-Recycled Water & Selected Chemical
More informationDigital flow transmitter for continuous flow measurement
Digital flow transmitter for continuous flow measurement Compact or remote version for DN 06 to 400, PN10 Shows both flow rate and volume (with two totalizers) Automatic-calibration: TEACH-IN Simulation:
More informationSERIE LSG \ LSG SERIES
INTERRUTTORE DI LIVELLO A GALLEGGIANTE SERIE LSG \ LSG SERIES LSG è un interruttore di livello a galleggiante progettato per il controllo del livello di liquidi sia in ambiente navale che in processi industriali.
More informationBATCHFLUX 5500 C Technical Datasheet
BATCHFLUX 5500 C Technical Datasheet Electromagnetic flowmeter for volumetric filling machines High-stability ceramic measuring tube, therefore extremely long-term stability Optimum hygienic design Only
More informationFlow Switch - 2 programmable thresholds. Stand Alone (Battery) - Battery powered, - 2 totalizers display, - Local flow display,
DN 15 - DN 50; PN Advantages / Benefits Easy System integration by Easy LINK provides low cost of ownership Easy commissioning due to multi-language, menu-guided operation TEACH-IN: automatic calibration
More informationSERIE 27M \ 27M SERIES
SERIE 27M \ 27M SERIES I convertitori/trasmettitori della serie 27M permettono di rilevare e convertire in un segnale elettrico pressioni relative (ad esempio 3 15 psi o 0.2 1 bar) e differenziali nell
More informationFlow Measurement SITRANS F M. Transmitter TRANSMAG 2 with sensor 911/E 4/101. Overview
Siemens AG 2010 Flow Measurement Overview Design The complete flowmeter consists of a flow sensor and an associated transmitter from the TRANSMAG 2 for pulsed alternating field. These are available as
More informationph or ORP Transmitter
ph or ORP Transmitter Programmable outputs: two transistor and single or dual analog 4-20 ma (Process + Temp) Removable backlighted display Universal process connection Compatible with 120 mm ph/ ORP probes
More informationDigital inductive conductivity transmitter
Digital inductive conductivity transmitter Optimal solution for conductivity measurements in difficult fluids (polluted, dirty,...) PEEK/PPA version for CIP applications Large range of process connections
More informationOPTIFLUX 5000 Technical Datasheet
OPTIFLUX 5000 Technical Datasheet Electromagnetic flowmeter in flanged version Exceptional long-term stability and accuracy For highly aggressive and abrasive fluids Fully vacuum-resistant with high-tech
More informationTIDALFLUX 2300 F Technical Datasheet
Technical Datasheet Electromagnetic flow sensor for partially filled pipes Measurement in partially filled pipes up to DN1600 / 64" Patented, non-contact level measurement Measurement possible down to
More informationR&D TECHNICAL SPECIFI
INTRODUCTION Present document defines technical specs of a three phase UPS covering the power range from 20 to 30 kva ON-LINE DOUBLE CONVERSION Uninterruptible Power Supply Systems with forced ventilation
More informationMC 308 CONVERTER MUT SERIES FLOWMETERS
MC 308 CONVERTER MUT SERIES FLOWMETERS Page 2 FLOMOTION SYSTEMS, Inc. www.flomotionsystems.com 716.691.3941 info@flomotionsystems.com FEBRUARY 2003 MC 308 CONVERTER MANUAL Including Installation Instructions
More informationElectromagnetic Flow Measuring System promag 35
Technical Information TI 035D/06/en No. 50075884 Electromagnetic Flow Measuring System promag 35 Applications Promag 35 S solves complex flow problems and is used to measure fluids with a high solids content,
More informationLevel Measurement. Continuous level measurement Radar transmitters SITRANS LR460. 4/258 Siemens FI
Overview The is a -wire, 2 GHz FMCW radar level transmitter with extremely high signal-to-noise ratio and advanced signal processing for continuous monitoring of solids up to 100 m (328 ft). It is ideal
More informationOPTIFLUX 1000 Technical Datasheet
OPTIFLUX 1000 Technical Datasheet Electromagnetic flow sensor in sandwich design Lightweight and compact Excellent price performance ratio Quick and easy to install The documentation is only complete when
More informationLevel Measurement Continuous level measurement Radar transmitters
Overview Benefits Process Intelligence for advanced signal processing and quick and easy adjustment Self-guided quick start wizard for plug and play startup 2 GHz provides superior reflective properties
More informationThe transducer component converts the measured signal and displays the actual value.
Digital inductive conductivity transmitter System Integration Provides low Total Cost of Ownership PEEK/PPA version for CIP applications TEACH IN and SIMULATION Function Approval PVDF Version PEEK Version
More informationMagnetic-Inductive flow Meter fmi
1 Product information fmi-c, fmi-r f o o d P H A R M A Magnetic-Inductive flow Meter fmi Application/Specified usage Magnetic-inductive flowmeter for the measurement of flow rate and volume in food and
More informationCondumax W CLS19. Technical Information. Conductivity sensors Two-electrode sensors with cell constants k = 0.01 cm 1 or k = 0.
Technical Information Condumax W CLS9 Conductivity sensors Two-electrode sensors with cell constants k = 0.0 cm or k = 0. cm Application Measurement in pure and ultrapure water: Monitoring ion exchangers
More informationIndice Index EURO 88 TRASMETTITORE UNIVERSALE UNIVERSAL TRANSMITTER 7. EURO 88 five.one CONVERTITORE PROGRAMMABILE PROGRAMMABLE CONVERTER 49
Soluzioni di elettronica Electronic Evolution 3 Indice Index EURO 88 TRASMETTITORE UNIVERSALE UNIVERSAL TRANSMITTER 7 TRASMETTITORE UNIVERSALE UNIVERSAL TRANSMITTER 8 FRONTALINO DI PROGRAMMAZIONE PROGRAMMING
More informationVersaFlow Ultrasonic clamp-on Flowmeter Technical Datasheet. Specification. Applications. Highlights. Industries. 34-VF September 2009
VersaFlow Ultrasonic clamp-on Flowmeter Technical Datasheet 34-VF-03-14 September 2009 Specification Clamp-on technology HONEYWELL S VERSAFLOW stands for continuity and long term reliability. Flow measurement
More informationRosemount Specifications. Product Data Sheet , Rev BA February 2009 PERFORMANCE SPECIFICATIONS
Rosemount 2051 Product Data Sheet PERFORMANCE SPECIFICATIONS Specifications For zero based spans, reference conditions, silicone oil fill, SST materials, Coplanar flange () or 1 /2 in. - 14 NPT () process
More informationAPT3200L SMART PRESSURE TRANSMITTER. Application Areas: WITH DIAPHRAGM SEAL
WITH DIAPHRAGM SEAL APT3200L Application Areas: Nuclear Water & Wastewater Chemicals Petrochemical Oil & Gas Pulp & Paper Food & Beverage, Pharmaceutical Power Renewable Energy Alternate Fuel Autrol America
More informationINTRODUCING SOME GREAT NEW PRODUCTS FROM OUR DWYER INSTRUMENTS RANGE:
Unit 1 / 14 Biscayne Way Jandakot WA 6104 P.O. Box 3232, Success WA 6964 Tel: (08) 9414 7666 Fax: (08) 9414 7677 Email: dg@dginstruments.com.au Website: www.dginstruments.com.au A.B.N: 59 113 005 959 DATE:
More informationLST400 Ultrasonic level / open channel flow transmitter
Data sheet DS/LST400 EN Rev.C LST400 Ultrasonic level / open channel flow transmitter Measurement made easy Reduced installation cost Easy access terminations Integrated echo display makes for easy troubleshooting
More informationprosonic T FMU230, FMU231
Technical Information prosonic T FMU230, FMU231 Ultrasonic Level Measurement Compact transmitters for non-contact level measurement of fluids and coarse bulk materials Application The compact transmitters
More informationAccuracy: ± 0.1 % of reading ±zero point stability (from liquids up to TMU-x040) Material: (316 L) / (316 Ti)/ Hastelloy C-22
Coriolis Massflowmeter for liquids and gas measuring monitoring analysing TMU S5 Measuring range: 0-60 kg/h 0-2200 t/h water Accuracy: ± 0.1 % of reading ±zero point stability (from liquids up to TMU-x040)
More informationAbridged Specifications: 10DS3111E/A Sensor with 50SM1000 Transmitter
Abridged Specifications: E/A Sensor with 50SM1000 Transmitter The E/A flanged sensors and 50SM1000 transmitters are AC magnetic flowmeters. These systems are recommended noisy slurries, applications involving
More informationEGC100W MAGMAX. Converter for Electromagnetic Flowmeter GENERAL FEATURES STANDARD SPECIFICATION. General Specification
EGCW Converter for Electromagnetic Flowmeter GENERAL MAGMAX EGCW is the high-performance separate type converter for electromagnetic flowmeters with the compact housing. Improved self-diagnostic functions
More informationA Higher Level of Performance. Data Sheet. Series Pressure and Level Transmitters. For more information, please visit >
A Higher Level of Performance Data Sheet Series 000 Pressure and Level Transmitters For more information, please visit > www.hawkmeasure.com Series 000 000-SAN Cable with separate electronics Description
More information210R3. Aluminium high precision pressure regulator. FEATURES Precision pressure regulator for inlet pressure up to 7 bar (101 psi).
Strada dei Boschi, 40 20852 Villasanta (MB) Italia tel. +39 039 30 2035 info@idinsertdeal.com www.idinsertdeal.com 210R3 Aluminium high precision pressure regulator FEATURES Precision pressure regulator
More informationSerie FQ / FQ Series
Sensori fotoelettrici M18 serie FQ con corpo corto M18 photoelectric sensors FQ Series with short body Modelli a diffusione diretta a corta e lunga distanza, polarizzati e a barriera / diffuse models with
More informationABB Instrumentation. Flowmeter. Specification DataFile
MagMaster Electromagnetic Flowmeter Specification DataFile Process MagMaster for unrivalled flow performance ±0.2% accuracy. Operable flow range of 0:1. Slurry MagMaster for all slurries, pulps and pastes.
More informationThe Radar Level Meters can be installed both in metallic or non metallic tanks; their use is not harmful to humans or environment.
1 EIP COMPACT WAVE 26 GHZ CW Series PULSE RADAR LEVEL INSTRUMENTS (26 GHz) DESCRIPTION The Radar Level Meters of EIP COMPACT WAVE 6.3 GHz series are excellent devices for no contact level measurement.
More informationSITRANS F flowmeters SITRANS F US SONOCAL /184 Siemens FI
Overview Integration The flowmeter pulse output is often used as input for heat calculators. The range of meters enables optimum measurement of energy consumption. The analog output is used to inform the
More informationFOTOCELLULE CILINDRICHE M18 TASTEGGIO DIRETTO PHOTOELECTRIC CYLINDRICAL SENSORS DIFFUSE TYPE
FOTOCELLULE CILINDRICHE M18 TASTEGGIO DIRETTO SERIE OCV81/D SERIES PHOTOELECTRIC CYLINDRICAL SENSORS DIFFUSE TYPE Turin / Torino Piemont Italy Email: info@selet.it FOTOCELLULE CILINDRICHE M18 TASTEGGIO
More informationCoriolis Mass Flow Meter Model TM
Coriolis Mass Flow Meter for liquids and gas measuring monitoring analysing TM S5 Measuring range: 0-0.8 kg / h 0-65000 kg / h water Accuracy: ± 0.1 of reading ± zero-point stability (liquids) p max :
More informationENRAF SERVO GAUGE 854 ATG Setting the standard in gauging.
ENRAF SERVO GAUGE 854 ATG Setting the standard in gauging. Technical Specifications Data Communication Honeywell Bi-phase mark (Pos 2 = E and I) 1200 / 2400 bps > 1,500 V Full galvanic separation via isolating
More informationKMS502F. ManuFlo Page 1 MANU ELECTRONICS PTY LTD Flow Measurement Products. Electromagnetic Flanged Flowmeters FEATURES: (sizes: 25mm to 200mm)
KMS502F Electromagnetic Flanged Flowmeters (sizes: 25mm to 200mm) FEATURES: For all your water applications including batching. Flanged connection suites ANSI 150lb flanges. Unsurpassed accuracy to ±0.5%
More informationLevel Measurement Continuous level measurement Radar transmitters
Overview Configuration Mounting on a nozzle is a 2-wire 25 GHz pulse radar level transmitter for continuous monitoring of solids and liquids in storage vessels including extreme levels of dust and high
More informationPlug & Play. No Calibration Required
No Calibration Required Plug & Play No K-actor Programming Read the User's Manual Carefully before Starting to Use the Unit. All TK Series low Meters are actory Calibrated. Manufacturer reserves the right
More informationResistance thermometers for process technology
Data Sheet 90.2820 Page 1/8 Resistance thermometers for process technology for temperatures from -200 to +600 C with protection tubes in stainless steel, titanium, tantalum, Iconel and Hastelloy available
More informationField IT Electro-Magnetic Flowmeters Mini-Mag with integral XE converter
Data Sheet D-FMP-10D1475W-Y_4 Field IT Electro-Magnetic Flowmeters Mini-Mag with integral XE converter 10D1475W/Y Flowmeter Systems utilizes a smart microprocessor converter. System accuracy of ±0.5% of
More informationSITRANS F flowmeters SITRANS F US. SONOFLO SONO 3000 transmitter. 4/152 Siemens FI Overview
Overview Design The transmitter is available in different enclosure to fit any demands: IP67 enclosure for compact or wall mounting IP00 as a 19 insert IP65 for wall mounting IP65 enclosure in stainless
More informationConductivity Analyzer
Data Sheet Conductivity Analyzer Comprehensive range of field-proven conductivity cells satisfies broad range of applications. Comprehensive diagnostics facility with in-built software protection ensures
More informationCondumax W CLS19. Technical Information. Conductivity sensors Two-electrode sensors with cell constants k = 0.01 cm 1 or k = 0.
Technical Information Condumax W CLS9 Conductivity sensors Two-electrode sensors with cell constants k = 0.0 cm or k = 0. cm Application Measurement in pure and ultrapure water: Monitoring ion exchangers
More informationDMH. Magnetic Inductive Flowmeter. for Conductive Fluids
Magnetic Inductive Flowmeter for Conductive Fluids measuring monitoring analyzing DMH Measuring Range: 0.29...26.4 to 431.6 43,333 GPM Accuracy: ± 0.3% of Reading ± 0.01% x Q max p max : 580 PSI t max
More informationcontrol & display PROGRAMMABLE SENSOR CONTROLLER COMPLETE VERSATILITY OF SENSOR MANAGEMENT & DATA COMMUNICATIONS
S E N S O R S PROGRAMMABLE SENSOR CONTROLLER TX9044 COMPLETE VERSATILITY OF SENSOR MANAGEMENT & DATA COMMUNICATIONS Analogue sensors, temperature devices, frequency inputs and digital sensors direct fingertip
More informationRCM DIRECT READING FLOWMETER
RCM DIRECT READING FLOWMETER Flow Pressure Level Temperature measurement monitoring control Special Features Compact Design Easy to Install For Horizontal or Vertical Pipes Rugged Construction Accuracy:
More informationAdvanced instrumentation solutions crafted with highest precision
www.adeptfluidyne.com Advanced instrumentation solutions crafted with highest precision perpendicular to both the liquid flow direction and the electromagnetic field direction. The voltage sensed by the
More informationElectromagnetic Flowmeter Comet F
Electromagnetic Flowmeter Comet F - Exact measurements - Comfortable calibration with PC - No setup elements - No pressure loss - Periodic cleaning of electrodes - Data backup during power failure - Communication
More informationSonoMeter 31 Energy Meters
SonoMeter 31 Energy Meters Description MID examination certificate no.: LT-1621-MI004-023 The Danfoss SonoMeter 31 is a range of ultrasonic, compact energy meters intended for measuring energy consumption
More informationDial-type digital bar graph. LEDs for Open Collector, Relays and Warning Indicator
Specifications General Input Channels One Input Types Digital (S 3 L) Serial ASCII, TTL level, 9600 bps Frequency Range 0.5 to 1500 Hz Accuracy 0.5% of reading Measurement Types Flow, ph/orp, Conductivity/Resis
More information