Abridged Specifications: 10DS3111E/A Sensor with 50SM1000 Transmitter
|
|
- Dennis Summers
- 5 years ago
- Views:
Transcription
1 Abridged Specifications: E/A Sensor with 50SM1000 Transmitter The E/A flanged sensors and 50SM1000 transmitters are AC magnetic flowmeters. These systems are recommended noisy slurries, applications involving pulsating flow, and high speed of response applications. Sizes 1 to 12 in. (E); 14 in. to 24 in. (A) Transmitter Pressure Process Temperature Liner Electrodes Sensor Housing 50SM1000 up to F (see full specifications for more information) ANSI Class 150 (all sizes) and Class 300 (1 to 12 in.) flanges Up to 356 F (max limit varies with liner selection) Hard or soft rubber (2 to 24 in.); Polyurethane (2 to 24 in.); Neoprene (2 to 24 in.); PTFE (1 to 24 in.); Tefzel (1 to 12 in.); Linatex (2 to 24 in.) Flush, bullet nose or slurry type in 316 stainless steel; Hastelloy C; Titanium; Tantalum; Platinum- Iridium; Zirconium Epoxy painted cast Aluminum Sensor NEMA 4X (IP 65) General Purpose. Classification Option for FM Approved for Class I, Division 2, Groups A to D (See full Specifications for more information) Transmitter Classification System Accuracy Conductivity Excitation NEMA 4X (IP 65) General Purpose 1.0% (1.5 to 33.3 feet per second) Greater than 20 µs/cm AC Features/ Accidental sensor submergence (IP 67) Options Analog output Scaled frequency output Alarms Contact outputs Remote totalizer reset Empty pipe detection Bi-directional flow measurement Full Diagnostics Loop test mode Illuminated 2-line LCD display Communications HART, RS-485, or RS-232 options Mounting Transmitter Power Field mounted 115/230 V ac Complete product specifications and options can be viewed or downloaded from
2 Design Level (For Use w/remote 50SM1000 Converter) Sizes 1" to 12"... E Sizes 14" to 24"...A Meter Lay Length t Short Form (W-Mag), Standard (1/2" - 12" only)...d Liner Hard Rubber... A Soft, Natural Rubber... B Polyurethane... D PTFE Teflon... E Neoprene... L Tefzel... N Linatex (Consult Warminster for Price adder sizes 14")... P Size Y 25mm (1")...09 Y 40mm (1-1/2") mm (2") mm (3) mm (4") mm (6") mm (8") mm (10") mm (12 )...20 Poly or Neo. 350mm (14") mm (16") mm (18") mm (20") mm (24")...24 t Consult full specification for other options Y Teflon or Tefzel Liner only. Æ Customer electrical connection box has PG 13.5 cable seal connections. v Customer electrical connection box has 1/2" NPT conduit seal connections. U 12-inch size only with Polyurethane or Neoprene liner; F-F is 18-inches (457 mm).
3 Flange Standard/Pressure Rating ANSI Class P ANSI Class 300 Flange Material Carbon Steel, Standard Stainless Steel (150 Class only) Protector Plate None Required 316 Stl.Stl... B Hastelloy C... E Electrode Design Flush, Standard... 2 (Bullet Nose... 3 vslurry Service (14"-24" only)... 7 Electrode Material 316 Stainless Steel...B Hastelloy B...C Hastelloy C...D Titanium...E t Tantalum...F t Platinum/Iridium (14" Consult Factory)...H Zirconium...L Customer electrical connection box has 1/2 in. NPT conduit seal connections For Teflon lined meters only. Serves as grounding ring. t Teflon or Tefzel Liner only. ( 2" and larger sizes only. Electrode material must be Stainless Steel. v Liner must be Polyurethane, Linatex, or Neoprene and electrode material must be stainless steel.
4 Price Certification General Purpose... A FM Approved Cl I, Div. 2, Gps. A,B,C&D Standard... K Explosion Proof, FM Cl I, Div. 1, Gps B,C & D (1"-12" only)... L Enclosure Classification IEC 529 IP 65, NEMA 4X... 1 piec 529 IP 67, Accidental Submergence in water to 33 ft for 48 hrs... 2 U IEC 529 IP 68, Continuous Submergence in water to 33 ft... 5 UIEC 529 IP 67, Accidential Submergence to 33 ft. for 48 hrs and Potted Terminal Box (Level 9 Protection)... 9 Process Temperature Range (For Liner Selection) Teflon PTFE or Tefzel, up to 266 F (130 C)...1 Teflon PTFE up to 356 F (180 C) (1"-12" only)...2 Hard Rubber, Linatex up to 175 F (80 C)...3 Polyurethane/Neoprene up to 190 F (88 C)...4 Teflon PTFE 302ºF (150ºC)...5 Line/Excitation Frequency 50 Hz Hz, Standard...3 Customer Information Language English w/riveted SST Tag... 2 zenglish w/self Adhesive Tag... 8 Remote Converter Type 50SM Not specified... X Permantly Installed Signal Cable tfor Enclosure Classification 5 & 9 Only Cable Length 50 Feet...05 Not Required...XX p Standard 50 feet of cable furnished for each meter. U Cable is permanently attached and the length must be specified at time of order under "Permanently Installed Signal Cable" character. Level 5 is not available with Teflon liner material. t Consult Factory for Lengths over 50 feet. z Not available with continuous submergence enclosure (Class 5).
5 50SM1000 Excitation Frequency 50 Hz Hz... 3 Certification...A Primary Type (1/2" - 12")... 1 tv (14" - 24") SM1 Design Level... C Software Level... X Enclosure NEMA 4X Field housing w/pg 13.5 Conn...B NEMA 4X Field Housing w/1/2" NPT Conn. Standard D Contact Outputs Octocoupler...1 Relay Contact...2 Pulse Outputs / Data Link Without Without...0 Active Fwd & Rev. Without...1 Without RS Without RS Contact Function Error Alarm...AA Forward/Reverse Flow Signal...AB Forward/Reverse Flow Signal & 2 Process Alarms...AC 2 Process Alarms...BA v Power supply must be 115 VAC t Enclosure must be D Only available with primary type 1 Includes error alarm. Forward/reverse signal is always via relay.
6 50SM SM1 _ Additional Options None...A External Totalizer Reset...B Zero Return...C External Totalizer Reset & Zero Return...D Empty Pipe Detector...E Empty Pipe Detector & External Totalizer Reset...F HART Protocol...G HART Protocol & Empty Pipe Detection...H HART Protocol & Empty Pipe Det. & Tot. Reset...J HART Protocol & Totalizer Reset...T Power Supply Æ115 Vac...C 230 Vac...A Customer Information Language English... 2 Signal Cable Not Required... 0 Required for E (1/2" - 12")... 1 Required for A (14" - 24")... 2 External Totalizer Reset Switch Not Required... 0 vrequired... 1 Current Output 4 to 20 ma, Standard to 20 ma...2 Pulse output/data link must be 0 or 1. Æ Does not include power requirement for primary if Flowmeter Primary Type is feet of cable is furnished as standard. Maximum cable length is 100 feet. v Additional options must be B, D, F, J, or T.
Electro-Magnetic Flowmeters COPA-XE
Data Sheet Electro-Magnetic Flowmeters COPA-XE 10DX4311 Flowmeter system utilizes a smart microprocessor converter System accuracy of ± 0.5% of rate Field configurable via integral pushbuttons, eliminates
More informationField IT Electro-Magnetic Flowmeters Mini-Mag with integral XE converter
Data Sheet D-FMP-10D1475W-Y_4 Field IT Electro-Magnetic Flowmeters Mini-Mag with integral XE converter 10D1475W/Y Flowmeter Systems utilizes a smart microprocessor converter. System accuracy of ±0.5% of
More informationMagnetic Flowmeter Systems
Series 8700 Magnetic Flowmeter Systems THE 8700 SERIES... Model 8712 C/U - Easiest to use local operator interface and works with any manufacturer s flowtubes Model 8712H/8707 High-Signal System - Pulsed
More informationFlow Measurement SITRANS F M
Overview Mode of operation The flow measuring principle is based on Faraday s law of electromagnetic induction according to which the sensor converts the flow into an electrical voltage proportional to
More informationFlow Measurement SITRANS F M
Overview Mode of operation The flow measuring principle is based on Faraday s law of electromagnetic induction according to which the sensor converts the flow into an electrical voltage proportional to
More informationFlow Measurement SITRANS F M. Flow sensor MAG /49. Overview
Siemens AG 2010 Flow Measurement Overview Mode of operation The flow measuring principle is based on Faraday s law of electromagnetic induction according to which the sensor converts the flow into an electrical
More informationSITRANS F flowmeters SITRANS F M. Flow sensor MAG /48 Siemens FI Overview
Siemens AG 2009 Overview Integration The complete flowmeter consists of a flow sensor and an associated transmitter MAG 5000, 6000 or 6000 I. The flexible communication concept USM II simplifies integration
More informationwww. otech.com.sg EFS801 ELECTROMAGNETIC FLOWMETER
www. otech.com.sg EFS801 ELECTROMAGNETIC FLOWMETER 1 www. otech.com.sg EFS801 - CFT181/RFT201 ELECTROMAGNETIC FLOWMETER Accurate, Reliable and Stable Flow Measurement. Measuring Principle The measuring
More informationE l e c t r o m a g n e t i c f l o w m e t e r s
E l e c t r o m a g n e t i c f l o w m e t e r s P r o v e n A N D R e l i a b l e F l o w M e a s u r e m e n t 2 MJK MagFlux flow meters combine high accuracy, stability and low maintenance. Without
More informationInstruction Manual. Model MLA & MLD Loop Powered Process Indicators IM 61A01A-01E-A. Model MLA (Analog) Model MLD (Digital)
Instruction Manual Model MLA & MLD Loop Powered Process Indicators Model MLD (Digital) Model MLA (Analog) 1. PREFACE The Model MLA and MLD field mounted indicators receive DC voltage or current signals
More information4/11. Overview. Easier service Transmitter replacement requires no programming. SENSORPROM automatically updates all settings after initialization.
Overview family are designed for measuring the flow of electrically conductive mediums. Benefits Easier commissioning of 5000, 6000, 6000 I All pulsed DC feature a unique SENSORPROM memory unit which stores
More informationSITRANS F flowmeters. SITRANS F M System information MAGFLO electromagnetic flowmeters 4/11
Overview family are designed for measuring the flow of electrically conductive mediums. Benefits System information FLO Easier to commission for 5000, 6000, 6000 I All FLO pulsed DC feature a unique SENSORPROM
More informationRHE12. Hazardous Area Coriolis Mass Flow Transmitter. Features. Applications. Benefits
RHE12 Hazardous Area Coriolis Mass Flow Transmitter Features Field mounting Compact, pressure safe housing ATEX and CSA approvals for installation in hazardous areas 24 VDC power supply Configurable analog
More informationFlow Measurement SITRANS F M. Transmitter TRANSMAG 2 with sensor 911/E 4/101. Overview
Siemens AG 2010 Flow Measurement Overview Design The complete flowmeter consists of a flow sensor and an associated transmitter from the TRANSMAG 2 for pulsed alternating field. These are available as
More informationRosemount 8700 Series. Magnetic Flowmeter Systems. Rosemount 8700 Series. Product Data Sheet , Rev NB Catalog
Magnetic Flowmeter Systems THE 8700 SERIES... Rosemount 8712 HART Transmitter - available with Device Diagnostics to improve reliability and performance. Provides quick setup with easy-to-use local operator
More informationABB Instrumentation. Flowmeter. Specification DataFile
MagMaster Electromagnetic Flowmeter Specification DataFile Process MagMaster for unrivalled flow performance ±0.2% accuracy. Operable flow range of 0:1. Slurry MagMaster for all slurries, pulps and pastes.
More informationMagFlux ELECTROMAGNETIC FLOWMETERS BROCHURE EN 3.05 MAGFLUX BROCHURE 1401
MagFlux ELECTROMAGNETIC FLOWMETERS BROCHURE EN 3.05 MAGFLUX BROCHURE 1401 P R O V E N A N D R E L I A B L E F L O W M E A S U R E M E N T 2 MJK MagFlux flow meters combine high accuracy, stability and
More informationSITRANS F flowmeters SITRANS F M. Transmitter Transmag 2 with sensor 911/E 4/77. Overview
Overview Design The complete flowmeter consists of a flow sensor and an associated transmitter from the Transmag 2 for pulsed alternating field. These are available as remote and compact versions ( 911/E
More informationKMS101W. ManuFlo Page 1 MANU ELECTRONICS PTY LTD Flow Measurement Products. Electromagnetic Wafer Flowmeters with S100 display
KMS101W Electromagnetic Wafer Flowmeters with S100 display ideal as resettable/batching meter (sizes: 15mm to 150mm) 0BFEATURES For ADMIXTURE Batching, Shotcrete, Mild-Recycled Water & Selected Chemical
More informationMagneW Two-wire PLUS+ Two-wire Electromagnetic Flowmeter
OVERVIEW MagneW Two-wire PLUS+ Two-wire Electromagnetic Flowmeter The MagneW Two-wire PLUS+is a high performance electromagnetic flowmeter based on field proven Azbil Corporation s two-wire loop powered
More informationMagnetic-inductive flow meter. PITe / UMF2. Technical Datasheet. Maintenance-free Nearly no pressure drop Robust design Easy installation and start-up
Magnetic-inductive flow meter Technical Datasheet PITe / UMF2 Maintenance-free Nearly no pressure drop Robust design Easy installation and start-up Subject to change without notice 1 Function An electrically
More informationKMS305W. ManuFlo Page 1 MANU ELECTRONICS PTY LTD Flow Measurement Products. Electromagnetic Wafer Flowmeters with S300 display
Electromagnetic Wafer Flowmeters with S300 display for corrosive chemicals/acids & slurries (sizes: 2.5mm to 100mm) 0BFEATURES: For aggressive chemicals, slurries, oxides, grouts & dosing applications
More informationRosemount 8700 Series. Magnetic Flowmeter Systems. Rosemount 8700 Series. Product Data Sheet , Rev NA July 2004.
Magnetic Flowmeter Systems THE 8700 SERIES... Rosemount 8712D Transmitter - Easiest to use local operator interface and works with any manufacturer s flowtubes Rosemount 8712H/8707 High-Signal System -
More informationAmbient Conditions. Operating Conditions. Pressure
Temperature Relative Humidity -20 C +75 C 0% 100 RH to 65 C non condensing 86 106 bar 4.0MPa (DN10 DN80) 1.6MPa (DN100 DN150) 1.0MPa (DN200 DN1000) Remote version < 80 C (rubber coating) Compact version
More informationRosemount 8712 D/H and 8732C Configuration Data Sheet
Rosemount 8712 D/H and 8732C Configuration Data Sheet CONFIGURATION DATA SHEET (Unless otherwise specified, transmitter will be shipped as Default Factory Configuration). Customer: P.O No: Transmitter
More informationAdvanced instrumentation solutions crafted with highest precision
www.adeptfluidyne.com Advanced instrumentation solutions crafted with highest precision perpendicular to both the liquid flow direction and the electromagnetic field direction. The voltage sensed by the
More informationRosemount 8750W Magnetic Flowmeter System
Rosemount 8750W Magnetic Flowmeter System for Utility, Water, and Wastewater Applications Product Data Sheet March 2015 00813-0300-4750, Rev AA Best in class value with performance, reliability, and diagnostics
More informationFlow Level Temperature Pressure Valves Analyzers Accessories TekValSys
Technology Solutions www.tek-trol.com 796 Tek Drive Crystal Lake, IL 60014 USA Tel: +1 847 857 6076, +1 847 655 7428 Fax: +1 847 655 6147 Flow Level Temperature Pressure Valves Analyzers Accessories TekValSys
More informationProduct Data Sheet Contents
Product Data Sheet 00813-0100-4793 Model 8742C Magnetic Flowmeter Transmitter with FOUNDATION Fieldbus THE MODEL 8742C Reduce process variability with high process noise detection Reduce commissioning
More informationRosemount 3101, 3102, and 3105
Product Data Sheet February 2013 00813-0100-4840, Rev DA Rosemount 3101, 3102, and 3105 Ultrasonic Liquid Level Transmitters Non-contacting measurement with no moving parts Integral LCD and buttons as
More informationS103C ELECTROMAGNETIC FLOW METERS. Main application fields MOUNTING
ELECTROMAGNETIC FLOW METERS The electromagnetic flow meter is used to measure the flow rate of conductive fluids and waste water. The measurement is independent of the density, viscosity, temperature and
More informationDOC. NO. : C3200-E04A APPROVED. Smart PressureTransmitter for Gauge and Absolute Pressure Measurement MODEL APT3200
DOC. NO. : C3200-E04A FM APPROVED Smart PressureTransmitter for Gauge and Absolute Pressure Measurement MODEL APT3200 APT3200 Smart Pressure Transmitter Standard SST Housing Description of Product The
More informationServo Gauge 854 XTG. Global Experience. Locally Applied. Cut costs, not repeatability.
Servo Gauge 854 XTG Cut costs, not repeatability. Honeywell Enraf s 854 XTG servo gauge is a high performance alternative to other tank level measurement technologies such as radar tank level gauges. It
More information8000A Series Compact Magnetic Flowtubes Wafer Body, Ceramic- or pfa-lined 1.6 to 150 mm (1/16 to 6 in) Line Sizes
Product Specifications 8000A Series Compact Magnetic Flowtubes Wafer Body, Ceramic- or pfa-lined to 150 mm (1/16 to 6 in) Line Sizes PSS 1-6F2 A 8000A SERIES MAGNETIC FLOWTUBE These compact, ceramic- or
More informationMadison Metropolitan Sewerage District Notice of Request for Proposals
Madison Metropolitan Sewerage District Notice of Request for Proposals Magnetic Flow Meter Published: September 21, 2017 in the Wisconsin State Journal The Madison Metropolitan Sewerage District requests
More informationDigital conductivity transmitter
Digital conductivity transmitter Compact version with integrated conductivity electrodes Remote version with seperated transmitter for short (15 ft.) or long (1500 ft.) distance Commissioning is easy due
More informationPAD - Heavy Duty Differential Pressure Trasmitter
Benefits and Features Span: 0.3" W.C. 6" W.C. to 60 6000 PSIG Static Pressure: Max. 4500 PSIG t max : 248 F Process Connection: ½" NPT, ¼" NPT, or Various Diaphragm Seals Available upon Request Material:
More informationPhD Inline Vortex. Performance Specifications Accuracy. Operating Specifications
Description The Vortex PhD vortex shedding flowmeter measures process fluid flow by detecting the frequency at which vortices are shed from an obstruction in the process fluid line (the bluff body). A
More informationSpecifications ELECTROMAGNETIC FLOWMETER. LF664/LF620 LF664/LF to 78 (500 to 1950mm) Overall Specifications TIC-LF664K
Field Intelligent Device Series-Mount Anywhere series-flanged ELECTROMAGNETIC FLOWMETER LF664/LF620 LF664/LF622 20 to 78 (500 to 1950mm) Introduction The electromagnetic flowmeter uses Faraday s Law of
More informationOPTIFLUX 5000 Technical Datasheet
OPTIFLUX 5000 Technical Datasheet Electromagnetic flowmeter in flanged version Exceptional long-term stability and accuracy For highly aggressive and abrasive fluids Fully vacuum-resistant with high-tech
More informationProcessMaster FEP300 Electromagnetic Flowmeter. The process industry's first choice
Change from one to two columns Data Sheet Rev. F ProcessMaster FEP300 Electromagnetic Flowmeter The process industry's first choice Intuitive operation Softkey-based functionality Easy Set-up function
More informationSmart Two-wire Electromagnetic Flowmeter
MagneW Two-wire PLUS + Smart Two-wire Electromagnetic Flowmeter Model MTG18A (Integral type) Model MTG14/MTG18B (Remote type) OVERVIEW The MagneW Two-wire PLUS + is a high performance electromagnetic flowmeter
More informationSITRANS F flowmeters SITRANS F US. Transmitter FUS060. Overview
Overview Function Displays and keypad Operation of the SITRANS FUS060 transmitter can be carried out using: Keypad and display unit HART communicator PC/laptop and SIMATIC PDM software via HART communication
More informationDMH. Magnetic Inductive Flowmeter. for Conductive Fluids
Magnetic Inductive Flowmeter for Conductive Fluids measuring monitoring analyzing DMH Measuring Range: 0.29...26.4 to 431.6 43,333 GPM Accuracy: ± 0.3% of Reading ± 0.01% x Q max p max : 580 PSI t max
More informationPrinco MagneLevel Model LML
Instrumentation designed with the user in mind Instruction Manual Princo MagneLevel Model LML Two-Wire Magnetic Coupled Level Transmitter 11 Nov 05 PRINCO INSTRUMENTS INC., 1020 INDUSTRIAL BLVD., SOUTHAMPTON,
More informationProcessMaster FEP300 Electromagnetic flowmeter. The process industry's first choice
Change from one to two columns Data Sheet Rev. I ProcessMaster FEP300 Electromagnetic flowmeter The process industry's first choice One solution for all your needs The versatile product tailored to meet
More informationTEK-TEMP 2100A. Explosion-Proof Temperature Transmitter. TEMPERATURE. Technology Solutions
Technology Solutions TEK-TEMP 2100A Explosion-Proof Temperature Transmitter TEMPERATURE www.tek-trol.com Flow Level Temperature Pressure Valves Analyzers Accessories TekValSys Introduction Tek-Trol s Explosion-Proof
More informationENRAF SERVO GAUGE 854 ATG Setting the standard in gauging.
ENRAF SERVO GAUGE 854 ATG Setting the standard in gauging. Technical Specifications Data Communication Honeywell Bi-phase mark (Pos 2 = E and I) 1200 / 2400 bps > 1,500 V Full galvanic separation via isolating
More informationModel Sono-Trak Transit Time
Model Sono-Trak Transit Time Ultrasonic Flow Meter Engineered for performance excellence, the Sono-Trak Transit Time ultrasonic meter combines non-invasive, bi-directional measurement with advanced ultrasonic
More informationKMS502F. ManuFlo Page 1 MANU ELECTRONICS PTY LTD Flow Measurement Products. Electromagnetic Flanged Flowmeters FEATURES: (sizes: 25mm to 200mm)
KMS502F Electromagnetic Flanged Flowmeters (sizes: 25mm to 200mm) FEATURES: For all your water applications including batching. Flanged connection suites ANSI 150lb flanges. Unsurpassed accuracy to ±0.5%
More informationOPTIFLUX 5000 Technical Datasheet
OPTIFLUX 5000 Technical Datasheet Electromagnetic flowmeter in flanged version Exceptional long-term stability and accuracy For highly aggressive and abrasive fluids Fully vacuum-resistant with high-tech
More informationCompact Orifice Flow Meter
Data Sheet DS/OM Issue 2 Compact Orifice Flow Meter OriMaster Integrated DP Flow measurement system combines primary element with DP Transmitter in a single flowmeter assembly One-piece flowmeter, pressure
More informationEN-2018 MAGNETIC FLOW METERS
EN-2018 MAGNETIC FLOW METERS www.meatest.com 1 MEASURING PRINCIPLE Having no moving or mechanical parts in the flow profile electromagnetic flow meters cause no pressure drop, are virtually maintenance
More informationRosemount Specifications. Product Data Sheet , Rev BA February 2009 PERFORMANCE SPECIFICATIONS
Rosemount 2051 Product Data Sheet PERFORMANCE SPECIFICATIONS Specifications For zero based spans, reference conditions, silicone oil fill, SST materials, Coplanar flange () or 1 /2 in. - 14 NPT () process
More informationJUMO flowtrans MAG S01
Phone: +49 661 6003-0 Fax: +49 661 6003-607 Internet: www.jumo.net Fax: +44 1279 635262 sales@jumo.co.uk Fax: 315-437-5860 info.us@jumo.net Page 1/57 JUMO flowtrans MAG S01 Electromagnetic flowmeter for
More informationLevel Measurement. Continuous level measurement - Radar transmitters SITRANS LR400 5/229. Overview
Overview Application It provides excellent results on low dielectric media. is available for standard applications and for applications that require explosion proof protection. features robust enclosure,
More informationABB MEASUREMENT & ANALYTICS DATA SHEET. HygienicMaster FEH630 Electromagnetic flowmeter
ABB MEASUREMENT & ANALYTICS DATA SHEET HygienicMaster FEH630 Electromagnetic flowmeter 2 HYGIENICMASTER FEH630 ELECTROMAGNETIC FLOWMETER DS/FEH630-EN REV. C Measurement made easy The clean choice for all
More informationFLOMID FX Electromagnetic Flowmeter
FLOMID FX Electromagnetic Flowmeter Working pressure manufacturing according to PED 97/23/CE (Lloyd s Register Certificate Nº 031) Introduction Modular design in two versions: Compact, sensor and electronics
More informationLevel Measurement. Continuous level measurement - Radar transmitters SITRANS LR400 5/229. Overview
Overview Application It provides excellent results on low dielectric media. is available for standard applications and for applications that require explosion proof protection. features robust enclosure,
More informationWATERFLUX 3070 Technical Datasheet
WATERFLUX 3070 Technical Datasheet Engineered and manufactured for the water and wastewater industry Highly accurate measurement with extremely short in- and outlet lengths Battery operated, stand alone
More informationTHE PROBE, 5 METER, 2WIRE, LOOP POWERED SINGLE POINT LEVEL MEASUREMENT SYSTEM (ULTRASONIC)
THE PROBE, 5 METER, 2WIRE, LOOP POWERED SINGLE POINT LEVEL MEASUREMENT SYSTEM (ULTRASONIC) Part 1. General 1.1 Scope A. This section describes the requirements for an ultrasonic, single-point level controller
More informationOPTIFLUX 1000 Technical Datasheet
OPTIFLUX 1000 Technical Datasheet Electromagnetic flow sensor in sandwich design Lightweight and compact Excellent price performance ratio Quick and easy to install The documentation is only complete when
More informationAPT3100 MODEL. Smart Pressure Transmitter. for Differential / Gauge / Absolute Pressure Measurement. Doc. No. : C3100-E05A
Doc. No. : C3100-E05A Smart Pressure Transmitter for Differential / Gauge / Absolute Pressure Measurement MODEL APT3100 Duon System Co.,Ltd. www.autrol.com Smart Pressure Transmitter APT3100 Standard Description
More informationElectromagnetic Flowmeter FXE4000 (COPA-XE/MAG-XE)
Contents Data Sheet D184S75U2 Electromagnetic Flowmeter FXE4 (COP-XE/MG-XE) The Electromagnetic Flowmeter (EMF) can be used to accurately measure the flowrate of liquids which have an electrical conductivity
More informationProcessMaster FEP500 Electromagnetic Flowmeter. The process industry's first choice. Maximum measuring accuracy Maximum measuring error: 0.
Change from one to two columns Data Sheet Rev. B ProcessMaster FEP500 Electromagnetic Flowmeter The process industry's first choice Intuitive operation Softkey-based functionality Easy Set-up function
More informationOriMaster FPD500 Compact orifice flowmeter. Orifice-based flow metering made simple
Data sheet DS/FPD500 EN Rev. E OriMaster FPD500 Compact orifice flowmeter Orifice-based flow metering made simple Integrated DP flow measurement system, pressure tested as an assembly combines primary
More informationTEK-F LEX 4100A. Guided Wave Radar Level Transmitter. LEVEL. Technology Solutions
Technology Solutions TEK-F LEX 4100A Guided Wave Radar Level Transmitter LEVEL www.tek-trol.com Flow Level Temperature Pressure Valves Analyzers Accessories TekValSys Introduction Featuring TDR (Time Domain
More informationElectromagnetic Flowmeter Hygienic/Sanitary
MagMaster Electromagnetic Flowmeter Hygienic/Sanitary Specification DataFile Unrivalled, fully traceable flow performance, ±0.2% accuracy. Operable flow range: 000 : ensures precise revenue measurement;
More informationAPT3200L SMART PRESSURE TRANSMITTER. Application Areas: WITH DIAPHRAGM SEAL
WITH DIAPHRAGM SEAL APT3200L Application Areas: Nuclear Water & Wastewater Chemicals Petrochemical Oil & Gas Pulp & Paper Food & Beverage, Pharmaceutical Power Renewable Energy Alternate Fuel Autrol America
More informationMobrey Ultrasonic. MSP422, MSP400RH, and MSP900GH Level Transmitters. Product Data Sheet February 2015 IP2045, Rev EA
Mobrey Ultrasonic Product Data Sheet February 215 IP245, Rev EA MSP422, MSP4RH, and MSP9GH Level Transmitters Non-contacting measurement with no moving parts Integral LCD and push-buttons as standard for
More informationSITRANS F flowmeters SITRANS F US SONOCAL /184 Siemens FI
Overview Integration The flowmeter pulse output is often used as input for heat calculators. The range of meters enables optimum measurement of energy consumption. The analog output is used to inform the
More informationFSM4000 Electromagnetic Flowmeter. Measurement made easy. The all-purpose flowmeter for conductive fluids
Conten ts Data Sheet D8S7U Rev. FSM Electromagnetic Flowmeter Measurement made easy The all-purpose flowmeter for conductive fluids Function Electromagnetic flowmeters can be used to accurately measure
More informationElectromagnetic Flow Measuring System promag 35
Technical Information TI 035D/06/en No. 50075884 Electromagnetic Flow Measuring System promag 35 Applications Promag 35 S solves complex flow problems and is used to measure fluids with a high solids content,
More informationFoxboro. FIELD DEVICES - FLOW Product Specifications PSS 1-6F8 A
FIELD DEVICES - FLOW Product Specifications Logo PSS 1-6F8 A I/A Series Intelligent Magnetic Flow Transmitters The Model IMT96 MagEXPERT with HART or FoxCom Communication Protocol for use with 2800 Series
More informationLevel Lance Model 5100
Sales Manual Section 100 Product Specification Model 5100 Level Lance Model 5100 GENERAL DESCRIPTION The Robertshaw Model 5100 Level-Lance is a microprocessor based, advanced technology On-Off level detection
More informationLevel Measurement Continuous level measurement Radar transmitters
Overview Benefits Process Intelligence for advanced signal processing and quick and easy adjustment Self-guided quick start wizard for plug and play startup 2 GHz provides superior reflective properties
More informationF-SERIES FOR. Indicators Totalizers Transmitters Flow computers Batch controllers Monitors. Flow Level Pressure Temperature
F-SERIES Indicators Totalizers Transmitters Flow computers Batch controllers Monitors Flow Level Pressure Temperature FOR F - SERIES F - SERIES F - SERIES F - SERIES F - SERIES F - SERIES F - SERIES F
More informationSmart Pressure Transmitter
DOC. NO. : C3200-E05A Smart Pressure Transmitter for Gauge and Absolute Pressure Measurement MODEL APT3200 Duon System Co.,Ltd. www.autrol.com AUTROL, AUTROL are trade mark of smart transmitter brand series
More informationLA-5000 SERIES LINEAR VALVE ACTUATORS
LA-5000 SERIES LINEAR VALVE ACTUATORS GENERAL DESCRIPTION The LA-5000 Series are bi-directional, linear actuators internally geared to produce up to 6,500 lbs. (28,913 N) of thrust, and offer continuous
More informationLevel Plus. Magnetostrictive Liquid-Level Sensors with Temposonics Technology. M-Series Model MR Transmitter with Analog Output.
Level Plus Magnetostrictive Liquid-Level Sensors with Temposonics Technology M-Series Model MR Transmitter with Analog Output Data Sheet SENSORS Document Part Number 550677 Revision K FEATURES 4 to 20
More informationG SERIES PRECISION METERS
Precision Meters PRECISION METERS The High Precision Meter line is the most accurate of the FLOMEC Turbine Meters and includes a traditional design. These meters come in a variety of sizes and fitting
More informationProcessMaster / HygienicMaster
SM/FEP300/FEH300/FM/CSA-EN ProcessMaster / HygienicMaster FM / cfm Div. 1, Div. 2 Safety information for electrical equipment for potentially explosive areas in accordance with Factory Mutual Standards
More informationMetal tube variable area flowmeters for gases, liquids and steam
Metal tube variable area flowmeters for gases, liquids and steam Metallic with a robust construction, optional in plastic Indication by means of magnetic coupling Linear scales, calibrated in l/h, m3/h,
More informationCoriolis Massflowmeter
Coriolis Massflowmeter for liquids and gas measuring monitoring analysing Measuring range: 0-0.8 kg / h 0-65 000 kg / h water Accuracy: ± 0.1 of reading ±zero-point stability (liquids) pmax: PN40 tmax:
More informationLevel Measurement. Continuous level measurement Radar transmitters SITRANS LR460. 4/258 Siemens FI
Overview The is a -wire, 2 GHz FMCW radar level transmitter with extremely high signal-to-noise ratio and advanced signal processing for continuous monitoring of solids up to 100 m (328 ft). It is ideal
More informationTarget disk flowmeters Series DP Metallic flowmeter for liquids and gases
Target disk flowmeters Series DP Metallic flowmeter for liquids and gases Metallic, simple and robust construction Available for all flow directions Suitable for extreme pressure and temperature conditions
More informationEfcon Water. Installation & User Manual Electro Magnetic Flowmeter (EMF) Efcon Water compact Electro Magnetic Flowmeter (EMF) Manual Version UK
Efcon Water Installation & User Manual Electro Magnetic Flowmeter (EMF) Page 1 Table of content Page 1.1 General 3 1.2 Application area 4 1.3 Transportation 4 1.4 Principle of Operation 4 1.5 Product Description
More informationLevel Plus. RefineME Data Sheet. Magnetostrictive Liquid Level Transmitters with Temposonics Technology
Level Plus Magnetostrictive Liquid Level Transmitters with Temposonics Technology RefineME 4-IN-1 Measurement Inherent Accuracy ±1 mm API Temperature Corrected Volumes No Scheduled Maintenance or Recalibration
More informationFLOWMETER. Siemens MAG 5000/6000. Overview
Overview Design The transmitter is designed as either IP67 NEMA 4X enclosure for compact or wall mounting or 19" version as a 19 insert as a base to be used in: 19" rack systems Panel mounting IP65/NEMA
More informationLevel Measurement Continuous level measurement Radar transmitters
Overview Configuration Mounting on a nozzle is a 2-wire 25 GHz pulse radar level transmitter for continuous monitoring of solids and liquids in storage vessels including extreme levels of dust and high
More informationMagnetic Inductive Flowmeter
Magnetic Inductive Flowmeter for conductivity liquids measuring monitoring analysing Measuring range: up to 10 m/s Accuracy: ±1.5% of reading ±0.5% full scale pmax: PN40 tmax: -40 +150 C Connection: flange
More informationSITRANS F flowmeters. SITRANS F M System information MAGFLO electromagnetic flowmeters 4/11
Overview family are designed for measuring the flow of electrically conductive mediums. Benefits SITRANS F flowmeters System information FLO Easier to commission All FLO feature a unique SENSORPROM memory
More informationIndumax CLS50/CLS50D. Technical Information
Technical Information Indumax CLS50/CLS50D Inductive conductivity sensor for standard, hazardous and high-temperature applications, analog or digital with Memosens protocol Application Indumax CLS50/CLS50D
More informationTIDALFLUX 2300 F Technical Datasheet
Technical Datasheet Electromagnetic flow sensor for partially filled pipes Measurement in partially filled pipes up to DN1600 / 64" Patented, non-contact level measurement Measurement possible down to
More informationBinMaster Price Book
BinMaster Price Book SmartSonic & SmartWave Prices Subject To Change Without Notice Not responsible for errors or omissions. F.O.B. Lincoln, Nebraska USA Shipping Address: 7201 N. 98th St., Lincoln, NE
More informationThe Metropolitan Sewer District of Greater Cincinnati
The Metropolitan Sewer District of Greater Cincinnati Little Miami WWTP Sludge Handling Process Upgrade Project ID 10270080 Date Issued: 06/14/2010 ADDENDUM NO. 2 This addendum will only be distributed
More informationProcess display RIA 261
Technical Information TI 083R/24/ae Process display RIA 261 Digital loop powered field display for 4 to 20 ma current loops Features and Benefits Loop powered display, no additional power supply cable
More informationRemote Controlled FOUNDATION Fieldbus Two-Wire ph/orp Transmitter
Model 4081 ph/orp Product Data Sheet PDS 71-4081P February 2000 Remote Controlled FOUNDATION Fieldbus Two-Wire ph/orp Transmitter REMOTE COMMUNICATION IS SIMPLE; use the hand-held infrared remote controller,
More informationMagnetostrictive Level Transmitter
Magnetostrictive Level Transmitter The Model KMD is an advanced, state-of-the-art, two-wire, Magnetostrictive-based level transmitter suitable for a wide range of process applications. The latest in microprocessor
More informationFlow Detection MDS Integral or Remote Housing FUNCTION TYPICAL USES. Microwave Doppler Switch Solids - Chute and Conveyor GHz Sender Receiver
Flow Detection MDS Integral or Remote Housing Microwave Doppler Switch Solids - Chute and Conveyor.525 GHz Sender Receiver FUNCTION Flow/no flow detection in solid material handling applications such as