www. otech.com.sg EFS801 ELECTROMAGNETIC FLOWMETER
|
|
- Luke Perkins
- 5 years ago
- Views:
Transcription
1 www. otech.com.sg EFS801 ELECTROMAGNETIC FLOWMETER 1
2 www. otech.com.sg EFS801 - CFT181/RFT201 ELECTROMAGNETIC FLOWMETER Accurate, Reliable and Stable Flow Measurement. Measuring Principle The measuring principle of the electromagnetic flowmeter (Magmeter) is based upon the Faraday s Law of electromagnetic induction; whereby a voltage is induced by an electrical conductor passing through a magnetic eld. The following equation is applicable to the induced voltage: U = kbvd where U k B V D Induced voltage Instrument constant Magnetic eld strength Velocity of the conductor Conductor width Applications In electromagnetic flowmeter, the medium acts as the electrical conductor when owing through the meter tube, the induced voltage is proportional to the average ow velocity (the faster the ow rate, the higher the voltage). The induced voltage is picked up by a pair of electrodes (mounted in the meter tube) and transmitted to a ow transmitter to produce various standardized output signals. Using the pipe cross-sectional area, the ow volume is calculated by the transmitter. isolv electromagnetic flowmeter can be used for precise flow measurement of all electrically conductive liquids - sludges, slurries, sewage, milk, water. The only pre-requisite being that the minimum conductivity of the medium is greater than 5μS/cm. Temperature, viscosity, density has no in uence on the measurement. With isolated inert linings and electrodes, Flow measurement of very corrosive liquids (eg: acids, caustic and corrosive chemicals) is not an issue. isolv electromagnetic owmeter has many applications across many industries environment. Chemical Water/wastewater Pulp and paper Marine & Offshore Pharmaceutical Building automation (HVAC) Food and beverage 2
3 EFS 801/CFT181 Integral Flow Transmitter RFT201 Remote Flow Transmitter EFS801 Flowhead Specification Performance Accuracy +/- 0.2% to 0.5% Repeatability +/- 0.1% or +/- 0.25% Fluid Conductivity > 5μS/cm Fluid Temperature: -25 C to 80 C (Standard) -25 C to 140 C - Depending On Liner Material & Coil Insulation Class Ambient Temperature -25 C to 0 C Sensor Model EFS 801 Size DN3 - DN2400 Type Flange DIN 2501/ ANSI/ JIS Pressure Rating Refer To Page 5 &. Higher Pressure Rating Available on Request Tube Material SS304 Liner Material (Wetted Parts) Neoprene Rubber / PTFE / PFA Electrode Material(Wetted Parts) SS31L/ Hastelloy C/ Tantalum/ Titanium/ Platinum-Iridium Alloy Flange Material Carbon Steel. Other Material Available on Request Housing Protection Class Carbon Steel with Epoxy Painting IP7 (Standard) IP8 (Optional) Transmitter Housing Type Remote Integral Model No RFT201 CFT181 Power Supply VAC, VDC Output Signal 4-20mA and Pulse Communications HART/ Profibus-PA/ RS485 Housing Cast Aluminum with Painting Protection Class IP5 (Standard) / IP7 (Optional) Cable Length 10m (standard), available up to 95m NA Cable Entry M20 X 1.5 (Std) / NPT ½ / G½ Note: Available for Explosion Proof version upon request 3
4 www. otech.com.sg Flowmeter Sizing and Selection Proper selection, sizing and installation of electromagnetic owmeter will ensure trouble free operation and cost saving. The following information will be required. 1) Type of liquid consider suitability of liner and electrodes 2) Conductivity = 5μS/cm 3) Maximum / minimum temperature 4) Maximum / minimum pressure. Negative pressure? 5) Maximum / minimum ow rates ) Solids content Flow Table Meter Size Qmin (m3/h) Qmax (m3/h) Meter Size Qmin (m3/h) Qmax (m3/h) , , , , , , , , , , , , , , , , , , , , , , , , , , , ,80.1 4
5 5 www. otech.com.sg Dimension - Sensor Size (mm) 3 ~ L W H PN PN PN PN Dimension (mm) Weight (kg) Note: Dimensions are based on DIN2501 standards.
6 www. otech.com.sg Dimension - Sensor Size Pressure Rating Dimension (mm) Weight (mm) (PN) L W H (kg) Dimensions are based on DIN2501 standards.
7 www. otech.com.sg Dimension - Transmitter RFT201 Remote Transmitter CFT181 Integral Transmitter 7
8 www. otech.com.sg Primary ow sensor in metal pipe Primary flow sensor in pipe runs with cathodic protection Primary ow sensor must be electrically isolated from the pipe. Protective rings for good grounding are compulsory. 5 1) Measuring ground 2) Grounding wire 10mm 2 Cu (AWG 7) Primary ow sensor in plastic pipe or in metal pipe with insulating coating / lining / painting 1) Measuring ground 2) Grounding wire 10mm 2 Cu (AWG 7) 3) Grounding rings 4) Screw bolts (insulated) 5) Connecting wire 10mm 2 Cu (AWG 7) 1) Measuring ground 2) Grounding wire 10mm 2 Cu (AWG 7) 3) Grounding rings Installation Location and position as required, but electrode axis ( x...x ) must be approximately horizontal. Pipe must be completely lled at all times. Flow direction - Avoid top / bottom Ensure there is suf cient clearance for installation and maintenance work. Straight inlet run minimum of 5xDN and outlet 2xDN (DN= meter size) measured from the electrode axis. Support the pipeline on both sides of the owmeter to minimise vibrations. Do not install owmeter in vicinity of strong electromagnetic elds. Example: High-tension electrical cables Install protective rings for plastic pipes and internally coated metal pipelines for proper grounding. 8
9 Some Typical Installations A & B - Preferred locations. (Pipe is fully filled!) C - Highest point of pipe run (Air bubbles accumulate in measuring tube causing incorrect or unstable measurements) D - Top/bottom flow direction to drain does not create a fully filled pipe condition causing unstable or inaccurate reading. Install in slightly ascending pipe section. If not possible, ensure adequate velocity to prevent air, gas or vapor from concentrating in the flow sensor. Install flow sensor in lower section of pipe. Install air valve downstream of flowmeter. Negative pressure (Vacuum) may damage the liner. Always install control and shutoff valves downstream of flowmeter to avoid flow profile distortion or possible negative pressure (Vacuum) Never install flow sensor on pump suction side (Vacuum!). May cause damage to the liner. Install flowmeter in bypass for heavily contaminated fluids. A) Flowmeter B) Flushing and cleaning without interrupting system operation 9
10 Ordering Information (Example) E801 Model E801 - EFS801 R201 Version C181 - R201 - Compact (CFT181) Remote (RFT201) P Liner H - Neoprene Rubber (Std) T - PTFE (Applicable to Max. Temp. < 100 C) P - PFA (Applicable to Max. Temp. < 140 C) 15 Meter Size 15 - ½" DN ¾" DN " DN ¼" DN ½" DN " DN50 5-2½" DN5 80-3" DN80 1H - 4" DN100 1Q - 5" DN125 1F - " DN150 2H - 8" DN 2F - 10" DN250 3H - 12" DN300 3F - 14 DN350 4H - 1 DN400 4F - 18 DN450 5H - 20 DN500 H - 24 DN00 7H - 28 DN700 8H - 32 DN800 9H - 3 DN900 1T - 40 DN DN DN DN DN1800 2T - 80 DN DN DN2400 S B Electrode S - SS 31 (Std) H - Hastelloy C M - Titanium T - Tantalum P - Platinum- Iridium Alloy Pressure Rating A - PN 10 B - PN 1 C - PN 25 D - PN40 E - ANSI 150 LBS F - ANSI 300 LBS H - JIS10K Flange Material 0 - Carbon Steel (Std) 3 - SS304 Accuracy 0 - ±0.5% (Std) 1 - ±0.2% Earthing Rings 0 - None C - Ground Ring (SS31) 10
11 Ordering Information (Example) 15 Earthing Rings Size [Selection based on Meter Size] 15 - ½" DN15 7H - 28 DN ¾" DN20 8H - 32 DN " DN25 9H - 3 DN ¼" DN32 1T - 40 DN ½" DN DN1 50-2" DN DN ½" DN5 1-4 DN " DN DN1800 1H - 4" DN100 2T - 80 DN0 1Q - 5" DN DN2 1F - " DN DN2400 2H - 8" DN 2F - 10" DN250 3H - 12" DN300 3F - 14 DN350 4H - 1 DN400 4F - 18 DN450 5H - 20 DN500 H - 24 DN C 0 Protection Class [Sensor+ Trensmitter] 1 - IP7 Sensor + IP5 Transmitter (Std) 2 - IP7 Sensor + IP7 Transmitter 3 - IP8 Sensor + IP7 Transmitter Temperature Range 0 - Standard Temperature <= 80 C (Std) H - High Temperature -25 to 140 C [for remote version (RFT201) only] Power Supply 0 - High Voltage VAC (Std) K - Low Voltage VDC In/ Output Options 0 - Current Output + Pulse Output (Std) 01 - Double Current Output 02 - RS HART protocol 04 - Profibus PA Cable Gland 0 - Converter Housing with Threads for Cable Connector M 20 x 1.5 (Std) 1 - Converter Housing with Threads for Cable Connector NPT 1/2" 2 - Converter Housing with Threads for Cable Connector G 1/2" Cable 0 - None [Compact Transmitter] C - Cable [Remote Transmitter] (Max. Length up to 50m) (10m - Std) Special Application 0 - None LN - With Long Neck Note: 1) High temperature application applicable to remote version only 2) Long neck application applicable for compact type Ordering Code: (Example) E801 R201 P 15 S B C 0 11
12 SALES AND SERVICE CENTRES REGIONAL NETWORK CHINA INDONESIA SINGAPORE - HEAD OFFICE FLOTECH CONTROLS PTE LTD Certificate SG95/0427 Certificate SG13/04547 MALAYSIA 30_0414
ELECTROMAGNETIC FLOWMETER
ELECTROMAGNETIC FLOWMETER ELECTROMAGNETIC FLOWMETER 1 EFS800 - CFT180/RFT200 ELECTROMAGNETIC FLOWMETER Accurate, Reliable and Stable Flow Measurement. Measuring Principle The measuring principle of the
More informationAmbient Conditions. Operating Conditions. Pressure
Temperature Relative Humidity -20 C +75 C 0% 100 RH to 65 C non condensing 86 106 bar 4.0MPa (DN10 DN80) 1.6MPa (DN100 DN150) 1.0MPa (DN200 DN1000) Remote version < 80 C (rubber coating) Compact version
More informationMagnetic-inductive flow meter. PITe / UMF2. Technical Datasheet. Maintenance-free Nearly no pressure drop Robust design Easy installation and start-up
Magnetic-inductive flow meter Technical Datasheet PITe / UMF2 Maintenance-free Nearly no pressure drop Robust design Easy installation and start-up Subject to change without notice 1 Function An electrically
More informationAdvanced instrumentation solutions crafted with highest precision
www.adeptfluidyne.com Advanced instrumentation solutions crafted with highest precision perpendicular to both the liquid flow direction and the electromagnetic field direction. The voltage sensed by the
More informationOPTIFLUX 1000 Technical Datasheet
OPTIFLUX 1000 Technical Datasheet Electromagnetic flow sensor in sandwich design Lightweight and compact Excellent price performance ratio Quick and easy to install The documentation is only complete when
More informationOPTIFLUX 5000 Technical Datasheet
OPTIFLUX 5000 Technical Datasheet Electromagnetic flowmeter in flanged version Exceptional long-term stability and accuracy For highly aggressive and abrasive fluids Fully vacuum-resistant with high-tech
More informationElectro-Magnetic Flowmeters COPA-XE
Data Sheet Electro-Magnetic Flowmeters COPA-XE 10DX4311 Flowmeter system utilizes a smart microprocessor converter System accuracy of ± 0.5% of rate Field configurable via integral pushbuttons, eliminates
More informationOPTIFLUX 5000 Technical Datasheet
OPTIFLUX 5000 Technical Datasheet Electromagnetic flowmeter in flanged version Exceptional long-term stability and accuracy For highly aggressive and abrasive fluids Fully vacuum-resistant with high-tech
More informationFLOMID FX Electromagnetic Flowmeter
FLOMID FX Electromagnetic Flowmeter Working pressure manufacturing according to PED 97/23/CE (Lloyd s Register Certificate Nº 031) Introduction Modular design in two versions: Compact, sensor and electronics
More informationDMH. Magnetic Inductive Flowmeter. for Conductive Fluids
Magnetic Inductive Flowmeter for Conductive Fluids measuring monitoring analyzing DMH Measuring Range: 0.29...26.4 to 431.6 43,333 GPM Accuracy: ± 0.3% of Reading ± 0.01% x Q max p max : 580 PSI t max
More informationFlow Measurement SITRANS F M. Flow sensor MAG /49. Overview
Siemens AG 2010 Flow Measurement Overview Mode of operation The flow measuring principle is based on Faraday s law of electromagnetic induction according to which the sensor converts the flow into an electrical
More informationSITRANS F flowmeters. SITRANS F System information MAGFLO electromagnetic flowmeters 4/9
Overview MAGFLO family MAGFLO electromagnetic are designed for measuring the flow of electrically conductive mediums. The patented MAGFLO Verificator guarantees accurate measurement and simple verification.
More informationSITRANS F flowmeters SITRANS F M. Flow sensor MAG /48 Siemens FI Overview
Siemens AG 2009 Overview Integration The complete flowmeter consists of a flow sensor and an associated transmitter MAG 5000, 6000 or 6000 I. The flexible communication concept USM II simplifies integration
More informationS103C ELECTROMAGNETIC FLOW METERS. Main application fields MOUNTING
ELECTROMAGNETIC FLOW METERS The electromagnetic flow meter is used to measure the flow rate of conductive fluids and waste water. The measurement is independent of the density, viscosity, temperature and
More informationFlow Measurement SITRANS F M
Overview Mode of operation The flow measuring principle is based on Faraday s law of electromagnetic induction according to which the sensor converts the flow into an electrical voltage proportional to
More informationElectromagnetic Flow Measuring System Two-wire, loop-powered PROline promag 23 P
Technical Information TI 049D/06/en 50097005 Electromagnetic Flow Measuring System Two-wire, loop-powered PROline promag 23 P Flow rate measurement in chemical or process applications Features and benefits
More informationMagnetic Inductive Flowmeter
Magnetic Inductive Flowmeter for conductivity liquids measuring monitoring analysing Measuring range: up to 10 m/s Accuracy: ±1.5% of reading ±0.5% full scale pmax: PN40 tmax: -40 +150 C Connection: flange
More informationFlow Measurement SITRANS F M
Overview Mode of operation The flow measuring principle is based on Faraday s law of electromagnetic induction according to which the sensor converts the flow into an electrical voltage proportional to
More informationTIDALFLUX 2300 F Technical Datasheet
Technical Datasheet Electromagnetic flow sensor for partially filled pipes Measurement in partially filled pipes up to DN1600 / 64" Patented, non-contact level measurement Measurement possible down to
More informationSITRANS F flowmeters. SITRANS F M System information MAGFLO electromagnetic flowmeters 4/11
Overview family are designed for measuring the flow of electrically conductive mediums. Benefits System information FLO Easier to commission for 5000, 6000, 6000 I All FLO pulsed DC feature a unique SENSORPROM
More information4/11. Overview. Easier service Transmitter replacement requires no programming. SENSORPROM automatically updates all settings after initialization.
Overview family are designed for measuring the flow of electrically conductive mediums. Benefits Easier commissioning of 5000, 6000, 6000 I All pulsed DC feature a unique SENSORPROM memory unit which stores
More informationElectromagnetic Flow Measuring System promag 35
Technical Information TI 035D/06/en No. 50075884 Electromagnetic Flow Measuring System promag 35 Applications Promag 35 S solves complex flow problems and is used to measure fluids with a high solids content,
More informationSITRANS F flowmeters SITRANS F M. Transmitter Transmag 2 with sensor 911/E 4/77. Overview
Overview Design The complete flowmeter consists of a flow sensor and an associated transmitter from the Transmag 2 for pulsed alternating field. These are available as remote and compact versions ( 911/E
More informationMagnetic Flowmeter Systems
Series 8700 Magnetic Flowmeter Systems THE 8700 SERIES... Model 8712 C/U - Easiest to use local operator interface and works with any manufacturer s flowtubes Model 8712H/8707 High-Signal System - Pulsed
More informationTechnical Information Proline Promag 10P
TI00094D/06/EN/13.17 71385977 Products Solutions Services Technical Information Electromagnetic flowmeter Flow measurement of liquids in chemical or process applications Application Electromagnetic flowmeter
More informationSITRANS F flowmeters. SITRANS F M System information MAGFLO electromagnetic flowmeters. 4/18 Siemens FI
Function All are based on Faraday s law of induction: U M = B v d k U M = Measured voltage induced in the medium perpendicular to the magnetic field and the flow direction. The voltage is tapped at two
More informationSITRANS F flowmeters. SITRANS F M System information MAGFLO electromagnetic flowmeters 4/11
Overview family are designed for measuring the flow of electrically conductive mediums. Benefits SITRANS F flowmeters System information FLO Easier to commission All FLO feature a unique SENSORPROM memory
More informationProline Promag 10P. Technical Information. Electromagnetic Flow Measuring System Flow measurement of liquids in chemical or process applications
Technical Information Proline Promag 10P Electromagnetic Flow Measuring System Flow measurement of liquids in chemical or process applications Application Electromagnetic flowmeter for bidirectional measurement
More informationMagneW Two-wire PLUS+ Two-wire Electromagnetic Flowmeter
OVERVIEW MagneW Two-wire PLUS+ Two-wire Electromagnetic Flowmeter The MagneW Two-wire PLUS+is a high performance electromagnetic flowmeter based on field proven Azbil Corporation s two-wire loop powered
More informationField IT Electro-Magnetic Flowmeters Mini-Mag with integral XE converter
Data Sheet D-FMP-10D1475W-Y_4 Field IT Electro-Magnetic Flowmeters Mini-Mag with integral XE converter 10D1475W/Y Flowmeter Systems utilizes a smart microprocessor converter. System accuracy of ±0.5% of
More informationKMS305W. ManuFlo Page 1 MANU ELECTRONICS PTY LTD Flow Measurement Products. Electromagnetic Wafer Flowmeters with S300 display
Electromagnetic Wafer Flowmeters with S300 display for corrosive chemicals/acids & slurries (sizes: 2.5mm to 100mm) 0BFEATURES: For aggressive chemicals, slurries, oxides, grouts & dosing applications
More informationFlow Measurement SITRANS F M. Transmitter TRANSMAG 2 with sensor 911/E 4/101. Overview
Siemens AG 2010 Flow Measurement Overview Design The complete flowmeter consists of a flow sensor and an associated transmitter from the TRANSMAG 2 for pulsed alternating field. These are available as
More informationKMS101W. ManuFlo Page 1 MANU ELECTRONICS PTY LTD Flow Measurement Products. Electromagnetic Wafer Flowmeters with S100 display
KMS101W Electromagnetic Wafer Flowmeters with S100 display ideal as resettable/batching meter (sizes: 15mm to 150mm) 0BFEATURES For ADMIXTURE Batching, Shotcrete, Mild-Recycled Water & Selected Chemical
More informationOPTIMASS 1000 Technical Datasheet
OPTIMASS 1000 Technical Datasheet Sensor for mass flow First choice for universal applications Best price-performance ratio A wide range of options available with no restrictions The documentation is only
More informationABB MEASUREMENT & ANALYTICS DATA SHEET. HygienicMaster FEH630 Electromagnetic flowmeter
ABB MEASUREMENT & ANALYTICS DATA SHEET HygienicMaster FEH630 Electromagnetic flowmeter 2 HYGIENICMASTER FEH630 ELECTROMAGNETIC FLOWMETER DS/FEH630-EN REV. C Measurement made easy The clean choice for all
More informationElectromagnetic Flow Transmitter
Electromagnetic Flow Transmitter Sensor in solid state technology Working as a transmitter and/or as an On/Off controller Automatic-calibration of full scale: Teach-In Clean in place (CIP) Type can be
More informationJUMO flowtrans MAG S01
Phone: +49 661 6003-0 Fax: +49 661 6003-607 Internet: www.jumo.net Fax: +44 1279 635262 sales@jumo.co.uk Fax: 315-437-5860 info.us@jumo.net Page 1/57 JUMO flowtrans MAG S01 Electromagnetic flowmeter for
More informationBATCHFLUX 5500 C Technical Datasheet
BATCHFLUX 5500 C Technical Datasheet Electromagnetic flowmeter for volumetric filling machines High-stability ceramic measuring tube, therefore extremely long-term stability Optimum hygienic design Only
More informationElectromagnetic Flowmeter FXE4000 (COPA-XE/MAG-XE)
Contents Data Sheet D184S75U2 Electromagnetic Flowmeter FXE4 (COP-XE/MG-XE) The Electromagnetic Flowmeter (EMF) can be used to accurately measure the flowrate of liquids which have an electrical conductivity
More informationProline Promag 55S. Technical Information
Technical Information Proline Promag 55S Electromagnetic Flow Measuring System Flow rate measurement of liquids with solids content or inhomogeneous liquids Application Electromagnetic flowmeter for bidirectional
More informationEN-2018 MAGNETIC FLOW METERS
EN-2018 MAGNETIC FLOW METERS www.meatest.com 1 MEASURING PRINCIPLE Having no moving or mechanical parts in the flow profile electromagnetic flow meters cause no pressure drop, are virtually maintenance
More informationWATERFLUX 3000 Quick Start
WATERFLUX 3000 Quick Start Electromagnetic flow sensor The documentation is only complete when used in combination with the relevant documentation for the signal converter. KROHNE CONTENTS WATERFLUX 3000
More informationRCM DIRECT READING FLOWMETER
RCM DIRECT READING FLOWMETER Flow Pressure Level Temperature measurement monitoring control Special Features Compact Design Easy to Install For Horizontal or Vertical Pipes Rugged Construction Accuracy:
More informationElectromagnetic Flow Measuring System promag 33
Technical Information TI 07D/06/en No. 50063743 Electromagnetic Flow Measuring System promag 33 Flexible System Wide choice of materials for process connections and measuring tube linings, compatible to
More informationFSM4000 Electromagnetic Flowmeter. Measurement made easy. The all-purpose flowmeter for conductive fluids
Conten ts Data Sheet D8S7U Rev. FSM Electromagnetic Flowmeter Measurement made easy The all-purpose flowmeter for conductive fluids Function Electromagnetic flowmeters can be used to accurately measure
More informationOPTISONIC Ultrasonic flowmeter for liquids in all industrial applications
OPTISONIC 3400 Ultrasonic flowmeter for liquids in all industrial applications Measurement of conductive and non-conductive, low and high viscous liquids, from -200 to +250 C / -328 to +482 F medium temperature
More informationMass Flowmeter CoriolisMaster FCM2000
Contents Data Sheet Mass Flowmeter CoriolisMaster FCM2000 Coriolis Mass Flowmeters are used for high precision measurement of mass flow and density. The fluid need not be electrically conductive. No moving
More informationABB Instrumentation. Flowmeter. Specification DataFile
MagMaster Electromagnetic Flowmeter Specification DataFile Process MagMaster for unrivalled flow performance ±0.2% accuracy. Operable flow range of 0:1. Slurry MagMaster for all slurries, pulps and pastes.
More informationElectromagnetic flowmeters and switches DWM 1000/2000
KROHNE 10/2000 D 20 DW10 02 E GR Electromagnetic flowmeters and switches DWM 1000/2000 Variable area flowmeters Vortex flowmeters Flow controllers Electromagnetic flowmeters Ultrasonic flowmeters Mass
More informationCoriolis Massflowmeter
Coriolis Massflowmeter for liquids and gas measuring monitoring analysing Measuring range: 0-0.8 kg / h 0-65 000 kg / h water Accuracy: ± 0.1 of reading ±zero-point stability (liquids) pmax: PN40 tmax:
More informationINLINE flowmeter for continuous flow measurement
INLINE flowmeter for continuous flow measurement Economic integration in pipe systems without any additional piping 3-wire frequency pulse version to directly interface with PLC s (both PNP and NPN) Connection
More informationKFS. Flap-type flow meter. Design and range of application
Design and range of application The measuring device operates largely independent of viscosity and is suitable for indicating the flow rate of water, acids, alkaline solutions and gases. Every device is
More informationINLINE flowmeter for continuous flow measurement
INLINE flowmeter for continuous flow measurement Economic integration in pipe systems without any additional piping 3-wire frequency pulse version to directly interface with PLC s (both PNP and NPN) Connection
More informationFull Metal Variable Area Flowmeter and Counter Model BGF
Full Metal Variable Area Flowmeter and Counter for horizontal and vertical mounting measuring monitoring analysing BGF OO Measuring range: 10-100... 6000-60000 l/h water 0.3-3.0... 170-1700 m³/h air (20
More information8000A Series Compact Magnetic Flowtubes Wafer Body, Ceramic- or pfa-lined 1.6 to 150 mm (1/16 to 6 in) Line Sizes
Product Specifications 8000A Series Compact Magnetic Flowtubes Wafer Body, Ceramic- or pfa-lined to 150 mm (1/16 to 6 in) Line Sizes PSS 1-6F2 A 8000A SERIES MAGNETIC FLOWTUBE These compact, ceramic- or
More informationMagnetic-Inductive flow Meter fmi
1 Product information fmi-c, fmi-r f o o d P H A R M A Magnetic-Inductive flow Meter fmi Application/Specified usage Magnetic-inductive flowmeter for the measurement of flow rate and volume in food and
More informationDensity (Consistency) Meter LQ500
Density (Consistency) Meter LQ500 Introduction The LQ500 density (consistency) meter uses microwave phase shift technology to determine concentrations of solids in the material to be measured flowing through
More informationMeasuring range: l/h water m³/h air (20 C, bar) Connection: Flange DN 15...
Full Metal Variable Area Flow Meter and Counter for Liquids and Gases monitoring analysing BGN Special versions up to 600 bar O Nominal diameter up to DN 150 S2 Measuring range: 0.5-5.0... 13000-130000
More informationElectromagnetic Flow Measuring System Two-wire, loop-powered PROline promag 23 H
Technical Information TI 051D/06/en 50097004 Electromagnetic Flow Measuring System Two-wire, loop-powered PROline promag 23 H Flow measurement in hygiene, food and beverage or process applications Features
More informationProline Promag 55S. Technical Information
Technical Information Proline Promag 55S Electromagnetic Flow Measuring System Flow rate measurement of liquids with solids content or inhomogeneous liquids Application Electromagnetic flowmeter for bidirectional
More informationAbridged Specifications: 10DS3111E/A Sensor with 50SM1000 Transmitter
Abridged Specifications: E/A Sensor with 50SM1000 Transmitter The E/A flanged sensors and 50SM1000 transmitters are AC magnetic flowmeters. These systems are recommended noisy slurries, applications involving
More informationTEK-F LEX 4100A. Guided Wave Radar Level Transmitter. LEVEL. Technology Solutions
Technology Solutions TEK-F LEX 4100A Guided Wave Radar Level Transmitter LEVEL www.tek-trol.com Flow Level Temperature Pressure Valves Analyzers Accessories TekValSys Introduction Featuring TDR (Time Domain
More informationINLINE flowmeter for continuous flow measurement
INLINE flowmeter for continuous flow measurement Economic integration in pipe systems without any additional piping 3-wire frequency pulse version to directly interface with PLC s (both PNP and NPN) Connection
More informationWATERFLUX 3000 Quick Start
WATERFLUX 3000 Quick Start Electromagnetic flowmeter The documentation is only complete when used in combination with the relevant documentation for the signal converter. KROHNE CONTENTS WATERFLUX 3000
More informationLevel gauges Series LT Level indicator, switch and transmitter for liquids
Level gauges Series LT Level indicator, switch and transmitter for liquids Simple construction Resistant under extreme temperature and pressure conditions No risk of leakage Excellent chemical resistance
More informationOPTIFLUX 2000 Technical Datasheet
OPTIFLUX 2000 Technical Datasheet Electromagnetic flow sensor For all water and wastewater applications Wide range of approvals for potable water Robust, fully welded construction The documentation is
More informationCoriolis Mass Flow Meter Model TM
Coriolis Mass Flow Meter for liquids and gas measuring monitoring analysing TM S5 Measuring range: 0-0.8 kg / h 0-65000 kg / h water Accuracy: ± 0.1 of reading ± zero-point stability (liquids) p max :
More informationJ Series induq VMZ MAGNETIC INDUCTIVE FLOW SENSORS. DB_Magnetic_Inductive_Flow_Sensors 05/2016
J Series induq VMM J Series induq VMI J Series induq VMZ MAGNETIC INDUCTIVE FLOW SENSORS J DB_Magnetic_Inductive_Flow_Sensors 5/216 67 Magnetic inductive flow sensors Principle of operation The smart flow
More informationINSERTION paddle wheel flowmeter for continuous flow measurement
INSERTION paddle wheel flowmeter for continuous flow measurement Economic integration in pipe systems without any additional piping 3-wire frequency pulse version to directly interface with PLC s (both
More informationDensity (Consistency) Meter
Density (Consistency) Meter LQ500 Introduction The LQ500 density (consistency) meter uses microwave phase shift technology to determine concentrations of solids in the material to be measured flowing through
More informationCoriolisMaster FCB330, FCB350, FCH330, FCH350 Coriolis mass flowmeter
Data Sheet DS/FCB300/FCH300-EN Rev. H CoriolisMaster FCB330, FCB350, FCH330, FCH350 Coriolis mass flowmeter 4-wire compact device For flow measurement of liquids and gases Measurement made easy CoriolisMaster
More informationBGN. All Metal Variable Area Flowmeter and Counter. for liquids and gases
All Metal Variable Area Flowmeter and Counter for liquids and gases monitoring analysing BGN Measuring range: 0.5-5.0... 13000-130000 l/h water 0.015-0.15... 240-2400 m³/h air (20 C, 1.013 bar) Accuracy
More informationFlow Technologies Overview. For internal use only / Siemens AG All Rights Reserved.
Flow Technologies Overview Mag Flow MAGFLO Program Siemens offers a comprehensive selection of electromagnetic flow meters Water & waste water Chemical Food & beverage Mining Aggregates Cement Pharmaceutical
More informationMass Flowmeter CoriolisMaster FCM2000
Contents Data Sheet Mass Flowmeter CoriolisMaster FCM2000 Coriolis Mass Flowmeters are used for high precision measurement of mass flow and density. The fluid need not be electrically conductive. No moving
More informationRosemount Specifications. Product Data Sheet , Rev BA February 2009 PERFORMANCE SPECIFICATIONS
Rosemount 2051 Product Data Sheet PERFORMANCE SPECIFICATIONS Specifications For zero based spans, reference conditions, silicone oil fill, SST materials, Coplanar flange () or 1 /2 in. - 14 NPT () process
More informationDigital flow transmitter for continuous flow measurement
Digital flow transmitter for continuous flow measurement Compact or remote version for DN 06 to 400, PN10 Shows both flow rate and volume (with two totalizers) Automatic-calibration: TEACH-IN Simulation:
More informationProline Promag 10W. Technical Information. Electromagnetic Flow Measuring System Flow measurement of liquids in water or wastewater applications
Technical Information Proline Promag 10W Electromagnetic Flow Measuring System Flow measurement of liquids in water or wastewater applications Application Electromagnetic flowmeter for bidirectional measurement
More informationWATERFLUX 3070 Technical Datasheet
WATERFLUX 3070 Technical Datasheet Engineered and manufactured for the water and wastewater industry Highly accurate measurement with extremely short in- and outlet lengths Battery operated, stand alone
More informationMetal tube variable area flowmeters for gases, liquids and steam
Metal tube variable area flowmeters for gases, liquids and steam Metallic with a robust construction, optional in plastic Indication by means of magnetic coupling Linear scales, calibrated in l/h, m3/h,
More informationAdvanced instrumentation solutions crafted with highest precision
www.adeptfluidyne.com Advanced instrumentation solutions crafted with highest precision Working Principle The Transit Time Flowmeter utilises two transducers that function as both ultrasonic transmitters
More informationRotamass TI Coriolis Mass flow meter
General Specifications Rotamass TI Coriolis Mass flow meter Rotamass Supreme Scope of application Precise flow rate measurement of fluids and gases, multi-phase media and media with specific gas content
More informationRotamass TI Coriolis Mass flow meter
General Specifications Rotamass TI Coriolis Mass flow meter Rotamass Prime Scope of application Precise flow rate measurement of fluids and gases, multi-phase media and media with specific gas content
More informationDigital inductive conductivity transmitter
Digital inductive conductivity transmitter Optimal solution for conductivity measurements in difficult fluids (polluted, dirty,...) PEEK/PPA version for CIP applications Large range of process connections
More informationRHE12. Hazardous Area Coriolis Mass Flow Transmitter. Features. Applications. Benefits
RHE12 Hazardous Area Coriolis Mass Flow Transmitter Features Field mounting Compact, pressure safe housing ATEX and CSA approvals for installation in hazardous areas 24 VDC power supply Configurable analog
More informationTechnical Information Proline Promag 55S
TI00071D/06/EN/14.17 71385973 Products Solutions Services Technical Information Electromagnetic flowmeter The flowmeter with outstanding abrasion resistance and integrated solids content diagnostics Application
More informationResistance thermometers for process technology
Data Sheet 90.2820 Page 1/8 Resistance thermometers for process technology for temperatures from -200 to +600 C with protection tubes in stainless steel, titanium, tantalum, Iconel and Hastelloy available
More informationFlow Level Temperature Pressure Valves Analyzers Accessories TekValSys
Technology Solutions www.tek-trol.com 796 Tek Drive Crystal Lake, IL 60014 USA Tel: +1 847 857 6076, +1 847 655 7428 Fax: +1 847 655 6147 Flow Level Temperature Pressure Valves Analyzers Accessories TekValSys
More informationThe transducer component converts the measured signal and displays the actual value.
Digital inductive conductivity transmitter System Integration Provides low Total Cost of Ownership PEEK/PPA version for CIP applications TEACH IN and SIMULATION Function Approval PVDF Version PEEK Version
More informationKMS502F. ManuFlo Page 1 MANU ELECTRONICS PTY LTD Flow Measurement Products. Electromagnetic Flanged Flowmeters FEATURES: (sizes: 25mm to 200mm)
KMS502F Electromagnetic Flanged Flowmeters (sizes: 25mm to 200mm) FEATURES: For all your water applications including batching. Flanged connection suites ANSI 150lb flanges. Unsurpassed accuracy to ±0.5%
More informationKFS-EM. Overall length. Al. PTFE coated Alu, painted Al. coated Methacrylate / acrylic nitrite
KFS Flap Flow Meter KFS suitable for H, acids, alkalis and gases spring-loaded horizontal or vertical flow direction low pressure loss mainly viscosity independent optional threshold value contacts optional
More informationA Higher Level of Performance. Data Sheet. Series Pressure and Level Transmitters. For more information, please visit >
A Higher Level of Performance Data Sheet Series 000 Pressure and Level Transmitters For more information, please visit > www.hawkmeasure.com Series 000 000-SAN Cable with separate electronics Description
More informationTarget disk flowmeter for liquids and gases
Target disk flowmeter for liquids and gases Metallic, simple and robust construction Available for all flow directions Suitable for extreme pressure and temperature conditions Low pressure drop Straight
More informationMS 5000 CIAO SENSOR EXTREMELY EASY TO INSTALL THANKS TO PATENTED WRAPPER FIXING SYSTEM
CIAO SENSOR MS 5000 EXTREMELY EASY TO INSTALL THANKS TO PATENTED WRAPPER FIXING SYSTEM Warranty conditions are available on this website: www.isomag.eu only in English version INDEX TECHNICAL DATA... 3
More informationEfcon Water. Installation & User Manual Electro Magnetic Flowmeter (EMF) Efcon Water compact Electro Magnetic Flowmeter (EMF) Manual Version UK
Efcon Water Installation & User Manual Electro Magnetic Flowmeter (EMF) Page 1 Table of content Page 1.1 General 3 1.2 Application area 4 1.3 Transportation 4 1.4 Principle of Operation 4 1.5 Product Description
More informationABB FCB330 FCH350 Mass Flowmeter datasheet
ABB FCB330 FCH350 Mass Flowmeter datasheet http://www.manuallib.com/abb/fcb330-fch350-mass-flowmeter-datasheet.html State of the art transmitter Easy handling Data safety due to unique sensor memory concept
More informationMagnetic Inductive Flowmeter DMH. Installation and Operating Instructions
Magnetic Inductive Flowmeter DMH Installation and Operating Instructions KOBOLD Messring GmbH DMH Installation and Operating Instructions Table of contents 1 SAFETY ADVISORIES... 4 1.1 Installation, commissioning,
More informationType PLC Fitting. Valve for Continuous control. Diaphragm valve. Output
Digital Inductive conductivity transmitter Optimal solution for conductivity measurements in difficult fluids (polluted, dirty,...) PEEK/PPA version for CIP applications Large range of process connections
More informationMagnetic Inductive Flow Sensors induq. Series VMI
Magnetic Inductive Flow Sensors induq Series VMI Free Flow! Compact - cost-effective - robust! The induq from SIKA is a trio of extremly compact, low cost, magnetic inductive fl ow sensors. This new product
More informationMIK COMPACT MAGNETO-INDUCTIVE FLOWMETER
MIK COMPACT MAGNETO-INDUCTIVE FLOWMETER Flow Pressure Level Temperature Measurement Monitoring Control Flow Ranges from 0.18-7.8 GPH through 9-180 GPM For Use with a Wide Variety of Conductive Liquids,
More informationOPTIFLUX 4000 Handbook