Type PLC Fitting. Valve for Continuous control. Diaphragm valve. Output

Size: px
Start display at page:

Download "Type PLC Fitting. Valve for Continuous control. Diaphragm valve. Output"

Transcription

1 Digital Inductive conductivity transmitter Optimal solution for conductivity measurements in difficult fluids (polluted, dirty,...) PEEK/PPA version for CIP applications Large range of process connections with various fittings for DN 15 to 200 Multi language, menu-guided operation Type 8226 can be combined with... Type S020 Type 6642 Type 2031 Type 2030 Type 8644 PLC Fitting Solenoid valve Valve for Continuous control Diaphragm valve Valve islands The conductivity transmitter Type 8226 combines a conductivity sensor and an electronic module with a display in an IP65 enclosure. The sensor component consists of a pair of magnetic coils in a PVDF or PEEK housing. The temperature sensor for automatic temperature compensation is a standard feature in the conductivity sensor housing. The conductivity transmitter can be installed into pipe by using Insertion fitting Type S020 available in stainless steel, brass or plastics. Technical data General data Compatibility Materials Housing, cover, lid, nut Front panel foil Screws Cable plug / gland Wetted parts materials Fitting Sensor holder / Seal Display Electrical connections Connection cable with all fittings S020 (see corresp. datasheet) PC glass reinforced fibre (if PVDF sensor) PPA glass reinforced fibre (if PEEK sensor) Polyester Stainless steel PA Brass, stainless steel /316L PVC, PP or PVDF PVDF or PEEK / FKM or EPDM 15 x 60 mm, 8-digit LCD, alphanumeric, 15 segments, 9 mm high Cable plug EN or cable glands M 20 x 1.5 Shielded, cross-section: max. 1.5 mm² Complete device data (fitting + electronic module) Pipe diameter DN 15 to 200 Conductivity measurement Measurement type Measuring range Accuracy Temperature measurement Measurement type Measuring range Accuracy inductive or resistive conductivity measurement 100 µs/cm...2 S/cm (cond.) or 0, kω.cm (resis.) ± 2 % o.r.* Numeric measurement C ±0.5 C from C and ±1 C from -40 C...0 C and 110 C C Medium temperature max. with fitting in PVC: 50 C - PP: 80 C - PVDF: 100 C, stainless steel, brass: 120 C Temperature compensation Fluid pressure max. automatic (with standardized integrated temperature sensor) - reference temperature 25 C PN6 (see pressure/temperature chart) Electrical data Power supply Current consumption with sensor Transmitter with relays Transmitter without relay Output Relays Environment Ambient temperature Operation and storage 0 to +60 C Relative humidity 80%, non condensated Standard and approvals Protection class Standard EMC Security Vibration Shock * o.r.= of reading V DC (regulated ± 5%) or 115/230 V AC 12 V DC-supply: 150 ma 24 V DC-supply: 90 ma 115/230 V AC-supply: 150 ma 12 V DC-supply: 70 ma 24 V DC-supply: 60 ma 115/230 VAC-supply: 150 ma 4-20 ma programmable, proportional to conductivity or temperature max. load: 1000 Ω at 30 V DC; 800 Ω at 24 V DC; 450 Ω at 15 V DC; 330 Ω at 12 V DC; 2 relays, freely programmable, 3A, 230 V AC IP65 with cable plug mounted and tightened EN , EN EN EN EN Page 1/6

2 Operation and display Customized adjustments, such as measuring range, engineering units and alarm setpoints can be carried out menu-supported on site via a multilingual display. The operation is classified according to three levels. Main Menu - conductivity - temperature - output current - HOLD function Calibration Menu - language - engineering units - cell constant - temperature compensation - measuring range 4-20 ma - relay function - filter selection Test Menu - Offset - Span - temperature correction - conductivity non compensated - simulation of conductivity - calibration of the zero point Direction upwards in menu Choice of digit values Steps from 0 to 9 Direction downwards in menu or sideways for digit selection Accept of chosen parameter or adjusted value Relay 2 LED (contact closed) Relay 1 LED (contact closed) Pressure / temperature chart Pressure (bar) Pressure (bar) 10 9 Nominal range 8 7 PVDF 6 5 PVC + PP PVDF (PN 6) PVC (PN 6) 1 PP (PN 6) Temperature ( C) Nominal range stainless steel / brass Temperature ( C) Principle of operation The conductivity is defined as the ability of a solution to conduct electrical current. The load carriers are ions (E.G. dissolved salt or acids). In order to measure conductivity, an AC voltage source is connected to the primary magnetic coil. The magnetic field induced generates a current in the secondary magnetic coil. The intensity of this induced current is a direct function of the conductivity of the solution. A ma standard signal is available as output signal, proportional to the conductivity or the temperature of the fluid. The transmitter is available, in option, with 2 relays. The transmitter without relay or with 2 additionnal relays (limits values freely adjustable) functions in a three wire circuit and requires a power supply of V DC. The device is available with an integrated power supply of 115/230 V AC. Page 2/6

3 Installation The 8226 conductivity transmitter can easily be installed into any Bürkert insertion fitting system (S020) by just fixing the main nut. The compact conductivity transmitter must be installed in a vertical position onto a horizontal pipe or a weld-in fitting must be used through a tank wall to obtain the vertical position. with mixer without mixer Horizontal mounting Vertical mounting Mounting in tank The transmitter must be protected from constant heat radiation and other environmental influences, such as direct exposure to sunlight. An industrial immersion kit allows installation of this transmitter into tank or containers. The following lengths are available: 500, 1000, 1500, 2000 mm. Special lengths on request. Dimensions [mm] 180 Immersion kit Ø 145 Ø 91 L 85.5 PVDF: 205 PEEK: L [mm] DN H [mm] [mm] T-Fitting Saddle Plastic St. St. Ø 75 Ø spigot* spigot Ø L H Page 3/6

4 Measuring chamber for conductivity transmitter Type 8226 The specially designed measuring chamber enables to install all conductivity transmitters or electrodes in all pipe systems, either directly in the main stream or in a by-pass line. Additionnaly it enables to keep the electrode always wet and isolate it easily from the main stream for calibration purposes ø 60.3 ø 60 B-B ø 33.6 ø B B Note: Materials: Stainless steel 316L Pipe connection: G1/ Combining the conductivity transmitter Type 8226 with fittings Type S020 Available Fitting DN T- fitting S020 Welding tab S020 Fusion spigot S020 DN6 DN50 DN65 DN65 DN200 DN200 conductivity measurement DN15 DN32 DN Note A Note A: Only with plastic fitting with true union connection DIN8063 Page 4/6

5 Ordering chart for compact conductivity transmitter Type 8226 A conductivity transmitter consists of: - an Insertion conductivity transmitter - an Insertion fitting S020 (DN15 - DN 200) (Refer to corresponding datasheet - has to be ordered separately) Specifications Voltage supply Output Relays Electrode version Seal 1) Electrical connection Item no. Compact transmitter V DC 4-20 ma None PVDF FKM EN cable glands PEEK EPDM EN cable glands PVDF FKM 2 cable glands PEEK EPDM 2 cable glands /230 V AC 4-20 ma None PVDF FKM 2 cable glands PEEK EPDM 2 cable glands PVDF FKM 2 cable glands PEEK EPDM 2 cable glands ) 1 Kit including a black EPDM gasket for the sensor, an obturator for an M 20 x 1.5 cable gland, a 2 x 6 mm multiway seal and a mounting instruction sheet is supplied with each transmitter with cable glands or 1 Kit including a green FKM and a black EPDM gaskets is supplied with each transmitter with connection EN Conductivity transmitter for tank installation consists of: - an Insertion conductivity transmitter - an extension cable for immersion fitting (*) - an immersion fitting (*) - a fixing kit - Flange DN65 with stainless steel screws (*) (*) see accessories / spare parts list Ordering chart accessories / spare parts Specifications Item no. Set with 2 cable glands M 20 x neoprene flat seals for cable gland or plug + 2 screw-plugs M 20 x multiway seals 2 x 6 mm Set with 2 reductions M 20 x 1.5 /NPT1/2 + 2 neoprene flat seals for cable gland or plug + 2 screw-plugs M 20 x Set with 1 stopper for unused cable gland M 20 x multiway seal 2 x 6 mm for cable gland + 1 black EPDM gasket for the sensor + 1 mounting instruction sheet Ring PC- Nut Set with 1 green FKM + 1 black EPDM gaskets Cable plug EN with cable gland (Type 2508) Cable plug EN with NPT1/2 reduction (Type 2509) - UR and UL approval Inductive conductivity sensor in PVDF Inductive conductivity sensor in PEEK Factory 2-point conductivity calibration certificate Measuring chamber stainless steel 316L (1.4404) 1) ) Other materials on request Page 5/6

6 Ordering chart accessories / spare parts (continued) For tank installation Specifications Item no. Immersion fitting - PP m Immersion fitting - PP m Immersion fitting - PP m Immersion fitting - PP m Extension cable for immersion fitting - PP m Extension cable for immersion fitting - PP m Extension cable for immersion fitting - PP m Extension cable for immersion fitting - PP m Fixing kit - Flange DN 65 with stainless steel screws Note: Conductivity transmitter 8226, connection cable, Insertion fitting S020, have to be ordered separately. Interconnection with other Bürkert products Type Diaphragmvalve with pilot valve Type Process valve with positioner Printer - Type Compact conductivity transmitter Measuring chamber Type S020 - Insertion Fitting (see corresp. datasheet) To find your nearest Bürkert facility, click on the orange box In case of special application conditions, We reserve the right to make technical changes 0512/1_EU-en_ please consult for advice. without notice. Page 6/6

Digital inductive conductivity transmitter

Digital inductive conductivity transmitter Digital inductive conductivity transmitter Optimal solution for conductivity measurements in difficult fluids (polluted, dirty,...) PEEK/PPA version for CIP applications Large range of process connections

More information

Digital flow transmitter for continuous flow measurement

Digital flow transmitter for continuous flow measurement Digital flow transmitter for continuous flow measurement Compact or remote version for DN 06 to 400, PN10 Shows both flow rate and volume (with two totalizers) Automatic-calibration: TEACH-IN Simulation:

More information

The transducer component converts the measured signal and displays the actual value.

The transducer component converts the measured signal and displays the actual value. Digital inductive conductivity transmitter System Integration Provides low Total Cost of Ownership PEEK/PPA version for CIP applications TEACH IN and SIMULATION Function Approval PVDF Version PEEK Version

More information

Electromagnetic Flow Transmitter

Electromagnetic Flow Transmitter Electromagnetic Flow Transmitter Sensor in solid state technology Working as a transmitter and/or as an On/Off controller Automatic-calibration of full scale: Teach-In Clean in place (CIP) Type can be

More information

Ultrasonic level transmitter, non-contact

Ultrasonic level transmitter, non-contact Ultrasonic level transmitter, non-contact Type 8175 can be combined with... Compact, remote versions for level measurement up to 10 m Multi language menu control Interference echo filter Automatic calibration:

More information

Digital conductivity transmitter

Digital conductivity transmitter Digital conductivity transmitter Compact version with integrated conductivity electrodes Remote version with seperated transmitter for short (15 ft.) or long (1500 ft.) distance Commissioning is easy due

More information

Conductivity Transmitter

Conductivity Transmitter Conductivity Transmitter Programmable outputs: two transistor and single or dual analog 4-20 ma Removable backlighted display Universal process connection Type can be combined with... Three cell constants

More information

ph or ORP Transmitter

ph or ORP Transmitter ph or ORP Transmitter Programmable outputs: two transistor and single or dual analog 4-20 ma (Process + Temp) Removable backlighted display Universal process connection Compatible with 120 mm ph/ ORP probes

More information

Digital flowmeter for continuous flow measurement

Digital flowmeter for continuous flow measurement 8025 Flowmeter INSERTION Digital flowmeter for continuous flow measurement Compact or remote version for DN06 to DN400, PN10 Displays both flow rate and volume (with two totalizers) On site calibration

More information

Digital flowmeter for continuous flow measurement

Digital flowmeter for continuous flow measurement 8025 Flowmeter INSERTION Digital flowmeter for continuous flow measurement Compact or remote version for DN06 to DN400, PN10 Displays both flow rate and volume (with two totalizers) On site calibration

More information

Digital flow ELEMENT transmitter for continuous flow measurement

Digital flow ELEMENT transmitter for continuous flow measurement ELEMENT Transmitter Digital flow ELEMENT transmitter for continuous flow measurement Type can be combined with... PN10, DN15 to DN400 fluidic process connection Programmable outputs : one or two transistor

More information

Digital flow ELEMENT transmitter for continuous flow measurement

Digital flow ELEMENT transmitter for continuous flow measurement Digital flow ELEMENT transmitter for continuous flow measurement Type 8036 can be combined with... DN06 to DN65 fluidic process connection Programmable outputs : one or two transistor output(s) and single

More information

Digital batch controller

Digital batch controller INSERTION Digital batch controller Type 8025 can be combined with... Compact or remote version for DN06 to DN400, PN10 Dosing On site calibration by Teach-In Check of input/output signals Total and daily

More information

INLINE flowmeter for continuous flow measurement

INLINE flowmeter for continuous flow measurement INLINE flowmeter for continuous flow measurement Economic integration in pipe systems without any additional piping 3-wire frequency pulse version to directly interface with PLC s (both PNP and NPN) Connection

More information

INLINE flowmeter for continuous flow measurement

INLINE flowmeter for continuous flow measurement INLINE flowmeter for continuous flow measurement Economic integration in pipe systems without any additional piping 3-wire frequency pulse version to directly interface with PLC s (both PNP and NPN) Connection

More information

INSERTION paddle wheel flowmeter for continuous flow measurement

INSERTION paddle wheel flowmeter for continuous flow measurement INSERTION paddle wheel flowmeter for continuous flow measurement Economic integration in pipe systems without any additional piping 3-wire frequency pulse version to directly interface with PLC s (both

More information

INLINE flowmeter for continuous flow measurement

INLINE flowmeter for continuous flow measurement INLINE flowmeter for continuous flow measurement Economic integration in pipe systems without any additional piping 3-wire frequency pulse version to directly interface with PLC s (both PNP and NPN) Connection

More information

Valve Island with Electronic I/O

Valve Island with Electronic I/O Screw in Temperature /Switch with display for ON/OFF Control Indication, monitoring, transmission and ON/OFF control in one device Extra large display Menu guided parametrisation Complete communication

More information

Flow Switch - 2 programmable thresholds. Stand Alone (Battery) - Battery powered, - 2 totalizers display, - Local flow display,

Flow Switch - 2 programmable thresholds. Stand Alone (Battery) - Battery powered, - 2 totalizers display, - Local flow display, DN 15 - DN 50; PN Advantages / Benefits Easy System integration by Easy LINK provides low cost of ownership Easy commissioning due to multi-language, menu-guided operation TEACH-IN: automatic calibration

More information

Ultrasonic level measuring device, non-contact

Ultrasonic level measuring device, non-contact Ultrasonic level measuring device, non-contact For level measurement up to 8 m 4... 20 ma/hart - 2 wires Suitable for solids ATEX approvals Type 8177 can be combined with... Type 8611 Type 8793 Type 8802-GB

More information

Conductivity sensor for hygienic applications

Conductivity sensor for hygienic applications Conductivity sensor for hygienic applications 2- or 4-electrode technology Extended measuring range 0.05 S/cm... 500 ms/cm Process connections, materials, surface finish designed for use in hygienic applications

More information

Insertion Flow sensor for continuous flow measurement

Insertion Flow sensor for continuous flow measurement Insertion Flow sensor for continuous flow measurement Economic integration into pipe systems 2 wire frequency coil (sinusoidal) version 3 wire frequency Hall effect (pulse) version to directly interface

More information

ma output signal with transmitter module. - Adjustable frequency output signal with pulse divider module

ma output signal with transmitter module. - Adjustable frequency output signal with pulse divider module / - ; 0 PSI Advantages / Benefits Wireless easy mounting and dismounting of sensor head by a Turn & Lock technique 3-wire Hall version to interface directly with PLC's (both NPN and PNP) Easy to connect:

More information

OEM radar transmitter, for aggressive media level measurement

OEM radar transmitter, for aggressive media level measurement OEM radar transmitter, for aggressive media level measurement C ompact for level measurement up to 20 m 4... 20 ma/hart - 2 wires Adjustable with P C ATEX approvals Type 8136 can be combined with... Type

More information

Technical Information Smartec CLD18

Technical Information Smartec CLD18 TI01080C/07/EN/02.14 71264779 Products Solutions Services Technical Information Smartec CLD18 Compact inductive conductivity measurement for the food and beverage industry Application Compact measuring

More information

Technical Information Smartec CLD18

Technical Information Smartec CLD18 TI01080C/07/EN/01.12 71195835 Products Solutions Services Technical Information Smartec CLD18 Compact inductive conductivity measurement for the food and beverage industry Application The compact measuring

More information

Paddle wheel flow controller for On/Off control

Paddle wheel flow controller for On/Off control addle wheel flow controller for On/Off control Type 8032 compact Type 8032 can be combined with... Type 8032 remote Indication, monitoring, transmitting and On/Off control in one device. rogrammable outputs

More information

Universal process controller econtrol

Universal process controller econtrol Universal process controller Type 8611 can be combined with... Continuous, 2point, 3point and On/Off control Ratio control function Sensor inputs (,, frequency, RDT) Control of proportional, process and

More information

Magnetic-inductive flow meter. PITe / UMF2. Technical Datasheet. Maintenance-free Nearly no pressure drop Robust design Easy installation and start-up

Magnetic-inductive flow meter. PITe / UMF2. Technical Datasheet. Maintenance-free Nearly no pressure drop Robust design Easy installation and start-up Magnetic-inductive flow meter Technical Datasheet PITe / UMF2 Maintenance-free Nearly no pressure drop Robust design Easy installation and start-up Subject to change without notice 1 Function An electrically

More information

Technical Information Smartec CLD18

Technical Information Smartec CLD18 TI01080C/07/EN/03.16 71314717 Products Solutions Services Technical Information Smartec CLD18 Compact inductive conductivity measurement for the food and beverage industry Application Compact measuring

More information

Universal process controller econtrol

Universal process controller econtrol Universal process controller Type 8611 can be combined with... Continuous, 2point, 3point and On/Off control Ratio control function Sensor inputs (,, frequency, Pt100) Control of proportional, process

More information

FLOWave SAW-Flowmeter

FLOWave SAW-Flowmeter SAW-Flowmeter No parts in the measurement tube 28-04 Conform to hygienic requirements Ideal for low conductivity or non conductive liquids Digital communication Type 8098 can be combined with... Compact,

More information

Condumax W CLS19. Technical Information. Conductivity sensors Two-electrode sensors with cell constants k = 0.01 cm 1 or k = 0.

Condumax W CLS19. Technical Information. Conductivity sensors Two-electrode sensors with cell constants k = 0.01 cm 1 or k = 0. Technical Information Condumax W CLS9 Conductivity sensors Two-electrode sensors with cell constants k = 0.0 cm or k = 0. cm Application Measurement in pure and ultrapure water: Monitoring ion exchangers

More information

prosonic T FMU230, FMU231

prosonic T FMU230, FMU231 Technical Information prosonic T FMU230, FMU231 Ultrasonic Level Measurement Compact transmitters for non-contact level measurement of fluids and coarse bulk materials Application The compact transmitters

More information

Condumax W CLS19. Technical Information. Conductivity sensors Two-electrode sensors with cell constants k = 0.01 cm 1 or k = 0.

Condumax W CLS19. Technical Information. Conductivity sensors Two-electrode sensors with cell constants k = 0.01 cm 1 or k = 0. Technical Information Condumax W CLS9 Conductivity sensors Two-electrode sensors with cell constants k = 0.0 cm or k = 0. cm Application Measurement in pure and ultrapure water: Monitoring ion exchangers

More information

JUMO CTI-500. Inductive Conductivity/Concentration and Temperature Transmitter with switch contacts. Type Brief description.

JUMO CTI-500. Inductive Conductivity/Concentration and Temperature Transmitter with switch contacts. Type Brief description. Page 1/17 JUMO CTI-500 Inductive Conductivity/Concentration and Temperature Transmitter with switch contacts Type 202755 Brief description The instrument is used for the measurement/control of conductivity

More information

Flow Measurement SITRANS F M

Flow Measurement SITRANS F M Overview Mode of operation The flow measuring principle is based on Faraday s law of electromagnetic induction according to which the sensor converts the flow into an electrical voltage proportional to

More information

Flow Measurement SITRANS F M

Flow Measurement SITRANS F M Overview Mode of operation The flow measuring principle is based on Faraday s law of electromagnetic induction according to which the sensor converts the flow into an electrical voltage proportional to

More information

2/2-Way Solenoid Control Valve

2/2-Way Solenoid Control Valve 2/2-Way Solenoid Control Valve Excellent range (1:200) Very good response Compact valve design Orifice sizes 0.8... 4 mm Port connection 1/8, 1/4 or sub-base Type 2873 can be combined with Type 8605 Digital

More information

J Series induq VMZ MAGNETIC INDUCTIVE FLOW SENSORS. DB_Magnetic_Inductive_Flow_Sensors 05/2016

J Series induq VMZ MAGNETIC INDUCTIVE FLOW SENSORS. DB_Magnetic_Inductive_Flow_Sensors 05/2016 J Series induq VMM J Series induq VMI J Series induq VMZ MAGNETIC INDUCTIVE FLOW SENSORS J DB_Magnetic_Inductive_Flow_Sensors 5/216 67 Magnetic inductive flow sensors Principle of operation The smart flow

More information

Magnetic-Inductive flow Meter fmi

Magnetic-Inductive flow Meter fmi 1 Product information fmi-c, fmi-r f o o d P H A R M A Magnetic-Inductive flow Meter fmi Application/Specified usage Magnetic-inductive flowmeter for the measurement of flow rate and volume in food and

More information

LCI. Inductive Conductivity/ Concentration and Temperature Transmitter. Compact or separate version

LCI. Inductive Conductivity/ Concentration and Temperature Transmitter. Compact or separate version Inductive Conductivity/ Concentration and Temperature Transmitter measuring monitoring analysing LCI or separate version Activation of up to four measuring ranges (up to 2000 ms/cm) Concentration measurement

More information

2/2 way Proportional Valve (motordriven)

2/2 way Proportional Valve (motordriven) 2/2 way Proportional (motordriven) Actuator isolated from fl ow path Excellent range and fast response times Low power consumption Orifi ce sizes 8 to 25 mm Versions: Standard, positioner, process controller

More information

2-way motor valve. Power consumption. Type 8746 MFC/MFM. Technical data Materials Body Housing Seals 1) Pressure Range 2) < 1 % FS Sensitivity Span

2-way motor valve. Power consumption. Type 8746 MFC/MFM. Technical data Materials Body Housing Seals 1) Pressure Range 2) < 1 % FS Sensitivity Span 2-way motor valve Actuator isolated from flow path Excellent range and fast response times Low power consumption Orifice sizes 1 to 10 mm Versions: Standard, positioner, process controller and high pressure

More information

Universal process controller econtrol

Universal process controller econtrol 8 Universal process controller Type 8 can be combined with... Continuous, point, point and On/Off control Ratio control function Sensor inputs (,, frequency, RTD) Control of proportional, process and motor

More information

SITRANS F flowmeters SITRANS F M. Transmitter Transmag 2 with sensor 911/E 4/77. Overview

SITRANS F flowmeters SITRANS F M. Transmitter Transmag 2 with sensor 911/E 4/77. Overview Overview Design The complete flowmeter consists of a flow sensor and an associated transmitter from the Transmag 2 for pulsed alternating field. These are available as remote and compact versions ( 911/E

More information

Pressure transmitter for general industrial applications Model A-10

Pressure transmitter for general industrial applications Model A-10 Electronic pressure measurement Pressure transmitter for general industrial applications Model A-10 WIKA data sheet PE 81.60 Applications Machine building Machine tools Measurement and control technology

More information

Inductive Conductivity Meter ILM

Inductive Conductivity Meter ILM 1 Product Information ILM-2 ILM-3 Inductive Conductivity Meter ILM f o o d Application / Specified Usage Authorizations Inductive measurement of the specific conductivity of liquid media in the range of

More information

Temperature Sensor Tri-Clamp

Temperature Sensor Tri-Clamp SENSORS FOR FOOD AND BIOPHARMA. Product Information TFP-47P, -67P, -167P PHARMA Temperature Sensor Tri-Clamp Application/Specified usage Temperature Measurement in vessels and pipes Authorizations Application

More information

} Max. Load Resistance : 750Ω when power supply voltage is 24V DC (Max. load resistance (Ω) = 50x Power Supply Voltage -450 ).

} Max. Load Resistance : 750Ω when power supply voltage is 24V DC (Max. load resistance (Ω) = 50x Power Supply Voltage -450 ). ISO-14001 ISO-9001 SPECIFICATION SHEET CP SERIES 2-WIRE TYPE DO TRANSMITTER Models: DCP-20T FEATURES Rigid aluminium enclosure with free angle mounting. Simple operation offers free range setting, auto-calibration,

More information

Conductivity measurement SmarTec S CLD 132

Conductivity measurement SmarTec S CLD 132 Technical Information TI 207C/24/ae Conductivity measurement SmarTec S CLD 132 Transmitter for measurement of conductivity and concentration with inductive sensor Areas of application Alkali/acid concentration

More information

PAD - Heavy Duty Differential Pressure Trasmitter

PAD - Heavy Duty Differential Pressure Trasmitter Benefits and Features Span: 0.3" W.C. 6" W.C. to 60 6000 PSIG Static Pressure: Max. 4500 PSIG t max : 248 F Process Connection: ½" NPT, ¼" NPT, or Various Diaphragm Seals Available upon Request Material:

More information

Inductive conductivity transmitter JUMO CTI-Junior

Inductive conductivity transmitter JUMO CTI-Junior M. K. JUCHHEIM GmbH & Co Delivery address:mackenrodtstraße 14, 36039 Fulda, Germany Postal address: 36035 Fulda, Germany Phone: +49 (0) 661 60 03-7 25 Fax: +49 (0) 661 60 03-6 81 E-Mail: mail@jumo.net

More information

Pressure Transmitter SIL

Pressure Transmitter SIL Pressure Transmitter SI Characteristics - TRANSDUCER - Pressure: Range: Output: Accuracy: Temperature of medium: Material enclosure: Pressure connection: Electrical connection: Protection: relative / absolute

More information

Flow Measurement SITRANS F M. Flow sensor MAG /49. Overview

Flow Measurement SITRANS F M. Flow sensor MAG /49. Overview Siemens AG 2010 Flow Measurement Overview Mode of operation The flow measuring principle is based on Faraday s law of electromagnetic induction according to which the sensor converts the flow into an electrical

More information

Pressure transmitter for general industrial applications Model A-10

Pressure transmitter for general industrial applications Model A-10 Electronic pressure measurement Pressure transmitter for general industrial applications Model A-10 WIKA data sheet PE 81.60 Applications Machine building Machine tools Measurement and control technology

More information

Measuring and Controlling Unit Multronic OC

Measuring and Controlling Unit Multronic OC Measuring and Controlling Unit Multronic OC One channel measuring and controlling unit for ph / conductivity / Chlorine measuring Automatic temperature compensation Measuring and control behaviour simultaneously

More information

DS 400 DS 400. Intelligent Electronic Pressure Switch Completely in Stainless Steel. piezoresistive stainless steel sensor

DS 400 DS 400. Intelligent Electronic Pressure Switch Completely in Stainless Steel. piezoresistive stainless steel sensor GmbH Postal address: House address Fon (+49) 0 22 42-870-0 Postbox 26 Löhestr. 7 Fax (+49) 0 22 42-870-20 http: // www.tematec.de 5759 Hennef 577 Hennef e-mail: team@tematec.de Data Sheet Page /5 Intelligent

More information

Design and applications

Design and applications Design and applications The measuring device operates largely independent of viscosity and is suitable for indicating the flow rate of water, acids, alkaline solutions and gases. Every device is calibrated

More information

Inductive Conductivity/Concentration and Temperature Transmitter with switch contacts. Temperature sensor. Graphics LC display.

Inductive Conductivity/Concentration and Temperature Transmitter with switch contacts. Temperature sensor. Graphics LC display. sales@jumo.co.uk info@jumo.us Page /8 JUMO CTI-750 Inductive Conductivity/Concentration and Temperature Transmitter with switch contacts Brief description The instrument is used for the measurement/control

More information

Endress Hauser. SmarTec M CLD 133 Conductivity Measurement

Endress Hauser. SmarTec M CLD 133 Conductivity Measurement Technical Information / Operating Instructions TI 281C/07/en/08.02 No. 51506567 SmarTec M Conductivity Measurement Compact conductivity transmitter with inductive sensor and integrated temperature compensation

More information

ED701 General Industry Pressure Transmitter

ED701 General Industry Pressure Transmitter ED701 General Industry Pressure Transmitter Standard industrial process connections Complete range of electrical connections 4... 20 ma and Voltage outputs Accuracy: 0.1%, 0.2% and 0.4% FS Quick response

More information

SITRANS F flowmeters SITRANS F M. Flow sensor MAG /48 Siemens FI Overview

SITRANS F flowmeters SITRANS F M. Flow sensor MAG /48 Siemens FI Overview Siemens AG 2009 Overview Integration The complete flowmeter consists of a flow sensor and an associated transmitter MAG 5000, 6000 or 6000 I. The flexible communication concept USM II simplifies integration

More information

Pressure transmitter For general industrial applications Model A-10

Pressure transmitter For general industrial applications Model A-10 Electronic pressure measurement Pressure transmitter For general industrial applications Model A-10 WIKA data sheet PE 81.60 Applications Machine building Ship building Measurement and control technology

More information

Measuring and Controlling Unit Multronic

Measuring and Controlling Unit Multronic Measuring and Controlling Unit Multronic Modular system Up to 3 measurement variables with control functions in one housing Free combination of the measurement variables ph / Redox / temperature / conductivity

More information

Temperature Sensor with M12 hygienic

Temperature Sensor with M12 hygienic SENSORS FOR AND BIOPHARMA. Product Information TFP-42, -52, -62, -162, -182 Temperature Sensor with M12 hygienic Application / Specified Usage Temperature Measurement in pipes DN15...DN80 Temperature measurement

More information

Temperature Sensor with Thread G1/4" FLEXadapt

Temperature Sensor with Thread G1/4 FLEXadapt SENSORS FOR FOOD AND BIOPHARMA. Product Information TFP-414, -614, -814 FOOD Temperature Sensor with Thread G1/4" FLEXadapt Application/Specified usage Temperature measurement in weld-in thermowells and

More information

DMP 343. Industrial Pressure Transmitter. Without Media Isolation. appmeas.co.uk +44 (0)

DMP 343. Industrial Pressure Transmitter. Without Media Isolation. appmeas.co.uk +44 (0) DMP 4 Industrial Pressure Transmitter Without Media Isolation accuracy according to IEC 60770: 0.5 % FSO Nominal pressure from 0... 0 mbar up to 0... 000 mbar Product characteristics excellent linearity

More information

JUMO Wtrans E01. Measuring probe for humidity, temperature, and CO 2 with wireless data transmission. Brief description. Universal Wtrans receiver

JUMO Wtrans E01. Measuring probe for humidity, temperature, and CO 2 with wireless data transmission. Brief description. Universal Wtrans receiver Page 1/13 JUMO Wtrans E01 Measuring probe for humidity, temperature, and CO 2 with wireless data transmission Humidity from 0 to 100 % RH (incl. -40 to +80 C) or CO 2 from 0 to 2000/5000/10000 ppm or Temperature

More information

Pharma-Temperature Sensor M12 hygienic

Pharma-Temperature Sensor M12 hygienic SENSORS FOR FOOD AND BIOPHARMA. Product Information TFP-42P, -52P, -62P, -162P, -182P PHARMA Pharma-Temperature Sensor M12 hygienic Application/Specified usage Temperature measurement in pipes DN15...DN80

More information

High-quality pressure transmitter For general industrial applications Model S-10

High-quality pressure transmitter For general industrial applications Model S-10 Electronic pressure measurement High-quality pressure transmitter For general industrial applications Model S-10 WIKA data sheet PE 81.01 for further approvals see page 4 Applications Machine building

More information

Continuous Level Sensor NSL-M

Continuous Level Sensor NSL-M SENSORS FOR FOOD AND BIOPHARMA. Product Information NSL-M-00, NSL-M-01 FOOD Continuous Level Sensor NSL-M Range of application Continuous level measurement in metallic vessels up to 3 m in height Ideal

More information

OPTIFLUX 5000 Technical Datasheet

OPTIFLUX 5000 Technical Datasheet OPTIFLUX 5000 Technical Datasheet Electromagnetic flowmeter in flanged version Exceptional long-term stability and accuracy For highly aggressive and abrasive fluids Fully vacuum-resistant with high-tech

More information

Condumax CLS15 and CLS15D

Condumax CLS15 and CLS15D Technical Information Condumax CLS15 and CLS15D Conductivity sensors, analog or digital with Memosens technology, Cell constant k = 0.01 cm -1 or k = 0.1 cm -1 Application Measurement in pure and ultrapure

More information

Temperature Sensor Tri-Clamp

Temperature Sensor Tri-Clamp 1 Product Information TfP-47, -67, -167 Temperature Sensor Tri-Clamp f o o d Application / Specified Usage Authorizations Temperature Measurement in vessels and pipes Application Examples Monitoring of

More information

General Purpose Toroidal Conductivity Sensors

General Purpose Toroidal Conductivity Sensors Product Data Sheet PDS 71-226/228/revE December 2009 Model 226 and 228 General Purpose Toroidal Conductivity Sensors NON-CONTACTING (TOROIDAL) SENSORS resist corrosion and fouling SENSORS ARE IDEAL for

More information

RTD Temperature Sensor omnigrad T -TSM 480, TR 480. Hygienic RTD sensor with Pt 100, class A TSM 480 with electronics programmable via PC

RTD Temperature Sensor omnigrad T -TSM 480, TR 480. Hygienic RTD sensor with Pt 100, class A TSM 480 with electronics programmable via PC Technical Information TI 273T/02/en 60021667 RTD Temperature Sensor omnigrad T -TSM 480, TR 480 Hygienic RTD sensor with Pt 100, class A TSM 480 with electronics programmable via PC Application The Omingrad

More information

Mobrey Ultrasonic. MSP422, MSP400RH, and MSP900GH Level Transmitters. Product Data Sheet February 2015 IP2045, Rev EA

Mobrey Ultrasonic. MSP422, MSP400RH, and MSP900GH Level Transmitters. Product Data Sheet February 2015 IP2045, Rev EA Mobrey Ultrasonic Product Data Sheet February 215 IP245, Rev EA MSP422, MSP4RH, and MSP9GH Level Transmitters Non-contacting measurement with no moving parts Integral LCD and push-buttons as standard for

More information

Temperature Sensor with M12 hygienic

Temperature Sensor with M12 hygienic 1 Product Information TFP-42, -52, -62, -162, -182 Temperature Sensor with M12 hygienic FOOD Application / Specified Usage Authorizations Temperature Measurement in pipes DN15...DN80 Temperature measurement

More information

ABB conductivity analyzer and probe package

ABB conductivity analyzer and probe package Water Technologies & Solutions fact sheet ABB conductivity analyzer and probe package series AX430 single input analyzer with PID control description and use Advanced measuring capabilities Conductivity

More information

OPTIWAVE 1010 Technical Datasheet

OPTIWAVE 1010 Technical Datasheet OPTIWAVE 1010 Technical Datasheet Radar (FMCW) Level Transmitter for bypass chambers and magnetic level indicators (BM 26 Advanced) Device welded to a bypass chamber with an optional IP68 level indicator

More information

P R o D u c T I n F o R m at I o n. TDR Level Sensor LFP. The clean solution

P R o D u c T I n F o R m at I o n. TDR Level Sensor LFP. The clean solution P R o D u c T I n F o R m at I o n TDR Level Sensor The clean solution Level sensors The clean solution Product description The is a hygienic level sensor for liquids using TDR technology a process for

More information

Pharma Temperature Sensor G3/8"

Pharma Temperature Sensor G3/8 SENSORS FOR FOOD AND BIOPHARMA. Product Information TFP-58P, -68P, -168P, -188P PHARMA Pharma Temperature Sensor G3/8" Application/Specified usage Aseptic temperature measurement, inline, high precise

More information

Condumax W CLS15 and CLS15D

Condumax W CLS15 and CLS15D Technical Information Condumax W CLS15 and CLS15D Conductivity sensors, analog or digital with Memosens technology, Cell constant k = 0.01 cm -1 or k = 0.1 cm -1 Application Measurement in pure and ultrapure

More information

Indumax CLS50/CLS50D. Technical Information

Indumax CLS50/CLS50D. Technical Information Technical Information Indumax CLS50/CLS50D Inductive conductivity sensor for standard, hazardous and high-temperature applications, analog or digital with Memosens protocol Application Indumax CLS50/CLS50D

More information

Pharma Temperature Sensor G3/8"

Pharma Temperature Sensor G3/8 1 Product Information TFP-58P, -68P, -168P, -188P Pharma Temperature Sensor G3/8" P H A R M A Application / Specified Usage Aseptic temperature measurement, inline, high precise and fast without product

More information

Dial-type digital bar graph. LEDs for Open Collector, Relays and Warning Indicator

Dial-type digital bar graph. LEDs for Open Collector, Relays and Warning Indicator Specifications General Input Channels One Input Types Digital (S 3 L) Serial ASCII, TTL level, 9600 bps Frequency Range 0.5 to 1500 Hz Accuracy 0.5% of reading Measurement Types Flow, ph/orp, Conductivity/Resis

More information

Pressure transmitter For general industrial applications Model A-10

Pressure transmitter For general industrial applications Model A-10 Electronic pressure measurement Pressure transmitter For general industrial applications Model A-10 WIKA data sheet PE 81.60 for further approvals see page 9 Applications Machine building Shipbuilding

More information

OEM pressure sensor For industrial applications Models O-10 (T), O-10 (5)

OEM pressure sensor For industrial applications Models O-10 (T), O-10 (5) Pressure OEM pressure sensor For industrial applications Models O-10 (T), O-10 (5) WIKA data sheet PE 81.65 for further approvals see page 11 Applications Hydraulics and pneumatics Pumps and compressors

More information

Inductive Conductivity/Concentration and Temperature Transmitter with switch contacts

Inductive Conductivity/Concentration and Temperature Transmitter with switch contacts JUMO GmbH & Co. KG Delivery address:mackenrodtstraße 14, 36039 Fulda, Germany Postal address: 36035 Fulda, Germany Phone: +49 661 6003-0 Fax: +49 661 6003-607 e-mail: mail@jumo.net Internet: www.jumo.net

More information

Process transmitter Model UPT-20, with pressure port Model UPT-21, with flush diaphragm

Process transmitter Model UPT-20, with pressure port Model UPT-21, with flush diaphragm Electronic pressure measurement Process transmitter Model UPT-20, with pressure port Model UPT-21, with flush diaphragm WIKA data sheet PE 86.05 Applications Process technology Machine building and plant

More information

SITRANS F flowmeters. SITRANS F M System information MAGFLO electromagnetic flowmeters. 4/18 Siemens FI

SITRANS F flowmeters. SITRANS F M System information MAGFLO electromagnetic flowmeters. 4/18 Siemens FI Function All are based on Faraday s law of induction: U M = B v d k U M = Measured voltage induced in the medium perpendicular to the magnetic field and the flow direction. The voltage is tapped at two

More information

KFS. Flap-type flow meter. Design and range of application

KFS. Flap-type flow meter. Design and range of application Design and range of application The measuring device operates largely independent of viscosity and is suitable for indicating the flow rate of water, acids, alkaline solutions and gases. Every device is

More information

OPTIFLUX 1000 Technical Datasheet

OPTIFLUX 1000 Technical Datasheet OPTIFLUX 1000 Technical Datasheet Electromagnetic flow sensor in sandwich design Lightweight and compact Excellent price performance ratio Quick and easy to install The documentation is only complete when

More information

Quick Start Guide LIQ-QSG-226, Rev F June Rosemount 226. Toroidal Conductivity Sensors

Quick Start Guide LIQ-QSG-226, Rev F June Rosemount 226. Toroidal Conductivity Sensors Quick Start Guide LIQ-QSG-226, Rev F June 2017 Rosemount 226 Toroidal Conductivity Sensors Safety Information WARNING! HIGH PRESSURE AND TEMPERATURE HAZARD Before removing the senosr, reduce the process

More information

omnigrad T - TSM 480, TR 480. Technical Information. RTD Temperature Sensor Hygienic design TSM 480 with electronics programmable via PC

omnigrad T - TSM 480, TR 480. Technical Information. RTD Temperature Sensor Hygienic design TSM 480 with electronics programmable via PC Technical Information omnigrad T - TSM 480, TR 480 RTD Temperature Sensor Hygienic design TSM 480 with electronics programmable via PC Application areas The onmigrad T easytemp TSM 480 and TR 480 thermometers

More information

MIK COMPACT MAGNETO-INDUCTIVE FLOWMETER

MIK COMPACT MAGNETO-INDUCTIVE FLOWMETER MIK COMPACT MAGNETO-INDUCTIVE FLOWMETER Flow Pressure Level Temperature Measurement Monitoring Control Flow Ranges from 0.18-7.8 GPH through 9-180 GPM For Use with a Wide Variety of Conductive Liquids,

More information

OPTIFLUX 5000 Technical Datasheet

OPTIFLUX 5000 Technical Datasheet OPTIFLUX 5000 Technical Datasheet Electromagnetic flowmeter in flanged version Exceptional long-term stability and accuracy For highly aggressive and abrasive fluids Fully vacuum-resistant with high-tech

More information

Temperature Sensor with G1/2" hygienic

Temperature Sensor with G1/2 hygienic SENSORS FOR FOOD AND BIOPHARMA. Product Information TFP-41, -44, -51, -54, -61, -161, -164, -181, -184 FOOD Temperature Sensor with G1/2" hygienic Application/Specified usage Temperature Measurement in

More information

Conductivity / Temperature Transmitter LMIT 09

Conductivity / Temperature Transmitter LMIT 09 Conductivity / Temperature Transmitter ONE unit for CIP applications, concentration monitoring and make-up Measurement value logging covering five decades of measurement ranges from 0-200 µs/cm to 0-2

More information