SITRANS F flowmeters SITRANS F US SONOCAL /184 Siemens FI

Size: px
Start display at page:

Download "SITRANS F flowmeters SITRANS F US SONOCAL /184 Siemens FI"

Transcription

1 Overview Integration The flowmeter pulse output is often used as input for heat calculators. The range of meters enables optimum measurement of energy consumption. The analog output is used to inform the SCADA system about the actual volume flow values in the distribution network. The SONOFLO ultrasonic flowmeters type are designed for accurate, high resolution flow measurement in water based district heating plants e.g. local networks, boiler stations or substations and in chilled water applications. SONOFLO ultrasonic flowmeters type are designed and approved for custody transfer according to PTB, class C, OIML R75, class and a lot of local country approvals. The sensors are approved according to EU Directive 97/23/EC dated 29 May 1997 regarding fluid in group 1, classified in category III. Design EN Benefits No pressure drop Reliable and accurate flow measurements Long-term stability with excellent performance Can measure on all district water independent of water quality and conductivity Low cost of ownership Matched pair calibration of complete system Local country approvals Outputs: one analog, pulse and relay Application The main application for SONOFLO ultrasonic flowmeters type is to measure volume, on water at temperatures from 3 to 200 C (37. to 392 F) (depending on local approvals), in the following fields: District heating systems Chilled water systems Combined district heating- and chilled water systems Design The flow meter consists of a flow sensor type SONO 3300 CT, transmitter SONO 3000 CT without display incl. remote mounting device and pcs 10 m coaxial cables for connecting the flow sensor and the transmitter. The flow sensor is a 2-track direct shot sensor type with flanges and in the sizes DN 50 to DN 1200 (2 to 8 ). The transmitter is only available in the shown IP67 version. All systems are sealed for custody transfer. Technical specifications SONOFLO Flow part Accuracy Error in measurement at reference conditions; % of measured value Dynamic range 1:20 Pulse output ± 0,5% 1:50 Pulse output ± 3% Repeatability ± 0,25% Error in measurement at reference conditions; % of measured value Dynamic range 1:20 Pulse output ± 0,5% 1:50 Pulse output ± 3% Repeatability ± 0,25% Input Nominal size DN DN 1200 ( ) Process connections, PN designated, EN , type 11, B Transducers Rated operating conditions Ambient conditions Ambient temperature Operating Storage Degree of protection (enclosure) Medium conditions Liquid temperature Maximum flow velocity Design PN10(DN500...DN1200 ( )) PN 16 (DN DN 1200 ( )) PN25(DN200...DN1000 ( )) PN 0 (DN DN 100 (2... )) Integrated version welded into the pipe C (- 131 F) C ( F) depending on approval C (1 320 F) depending on approval C ( F) IP C (1 392 F) depending on approval 10 m/s (32 ft/s) 2-track sensor with flanges and integrated transducers Material Pipe DN DN 150 ( ): Steel GS-16 Mn5, mat. No DN DN 1200 ( ): Steel EN Flange DN DN 1200 ( ): Steel EN S235JRG2 Tranducers Stainless steel /18 Siemens FI

2 Technical specifications (continued) Certificates and approvals Material certificates Coaxial cable Transmitter SONO 3000 CT without display The sensor is supplied with a Siemens Certificate of Conformity Custody transfer PTB calss C, OIML R75 class, many other local approvals The first 0.5 m (19.7 inch) of the coaxial cable Diameter 5.3 mm (0.21 ) Length 0.5 m (19.7 ) Material PTFE Ambient temperature C ( F) Coaxial cable > 0.5 m (19.7 inch) Diameter 5.8 mm (0.23 ) Length Max. 250 m (820 ft) between sensor and transmitter. If distance exceeds 30 m (98.5 ft), please contact your Siemens partner. Material PE Ambient temperature C ( F) Output Analog output Measurement of Current Load <800Ω Time constant 5 s Pulse output Individually galvanically isolated, isolation voltage 500 V Volume flow ma Individually galvanically isolated, isolation voltage 500 V Measurement of Volume flow Pulse width 5 ms Pulse values l/pulse depending of size, see selection guide Output mode Passive V/max. 200 ma Relay output Time constant/hysteresys 5 s/0.5% F.S.O. Change-over relay Error indication Load 2 V, 0.5 A Cut-off: low flow 0.8% F.S.O. Rated operation conditions Ambient temperature IP67 version - Storage C ( F) Mechanical vibrations 2 g, Hz sinusoidal in all directions to IEC Degree of protection (enclosure) IP67 to EN and DIN 0050 IP20 to IEC and DIN 0050 IP65 to IEC and DIN 0050 Design Enclosure material Fibreglass reinforced polyamide Dimensional drawings and weight See dimensional drawings SITRANS F flowmeters Power supply Supply voltage and power consumption Certificates and approvals V +10%/-15%, Hz, VA EMC Emission EN Immunity EN Low voltage Acoording to EN Approvals IP67 version PTB, class C, OIML R75, class Siemens FI /185

3 Selection guide SONOCAL series 3000 flow part (DN 50 DN 1200) with standard Qn settings Flowmeter size nominal to EN DN 50 DN 65 DN 80 DN 100 DN 125 DN 150 DN 200 DN 250 Flow range Q max m 3 /h Q n m 3 /h Q min m 3 /h Flowrate at 20 ma Q 20mA m 3 /h Pulse output l/pulse Flowmeter size nominal to EN DN 300 DN 350 DN 00 DN 500 DN 600 DN 700 DN 800 DN 1000 DN 1200 Flow range Q max m 3 /h Q n m 3 /h Q min m 3 /h Flowrate at 20 ma Q 20mA m 3 /h Pulse output l/pulse Selection guide SONOCAL series 3000 flow part (DN 100 DN 250) with EN 13 settings Flowmeter size nominal to EN DN 100 DN 125 DN 150 DN 200 DN 250 Flow range Q max m 3 /h Q n m 3 /h Q min m 3 /h Flowrate at 20 ma Q 20mA m 3 /h Pulse output l/pulse Analog output 20 ma (bidirectional) Relay output Error indication of flowmeter Pressure drop No pressure drop, the sensor is a straight pipe Straight inlet pipe Typically max. 10 * DN straight inlet pipe Accuracy Depending on local approvals /186 Siemens FI

4 Dimensional drawings Flow sensor SONO 3300 CT flow part L Do Size Build-in length L between the flanges Do Pipe wall thickness for 1) Outside diameter DN PN 10 PN 16 PN 25 PN 0 PN 10 PN 16 PN 25 PN 0 [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] ±3 75 ±3 75 ± ±3 75 ±3 75 ± ±3 00 ±3 00 ± ±3 00 ±3 00 ± ±3 00 ±3 00 ± ±3 00 ±3 00 ± ± 90 ± 500 ± ±5 575 ±5 600 ± ±5 560 ±5 600 ± ±5 80 ±5 880 ± ±5 925 ±5 975 ± ±6 980 ± ± ± ± ± ± ±6 110 ± ± ± ±6 120 ± ± ± ± ± ± ± ± ± ) The stated wall thickness for DN DN 1200 are minimum values according to the EC Directive on the Pressure Equipment 97/23/EC. Siemens FI /187

5 Size Build-in length L between the flanges Do Outside diameter Pipe wall thickness for 1) [inch] PN 10 PN 16 PN 25 PN 0 PN 10 PN 16 PN 25 PN 0 [inch] [inch] [inch] [inch] [inch] [inch] [inch] [inch] [inch] ± ± ± ½ ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ±0.2.8 ± ± ± ± ± ± ± ± ± ± ± ± ± ) The stated wall thickness for are minimum values according to the EC Directive on the Pressure Equipment 97/23/EC. Weight of sensor SONO 3300 CT Size Weight PN 10 PN 16 PN 25 PN 0 DN inch kg lbs kg lbs kg lbs kg lbs ½ /188 Siemens FI

6 Transmitter SONO 3000 CT, IP67, wall mounting 71 Schematics SITRANS F flowmeters Flow direction Up Down Ø8 Ø12 Ø A B C D Add approximately 30 mm (1.18 inch) on each side for cabling, approx. 2 kg (. lb) ma Load 800 W Error Freq/Pulse (Relay shown in de-energised condition) TH T + C Supply voltage PE 2 1 N L 115/230 V a.c. Electrical connections Siemens FI /189

7 SITRANS F flowmeters Selection and Ordering data Flowmeter Order-No. Order Code 7 ME Diameter Qn [m 3 /h] Cast steel, mat. no /GS-16Mn5 DN C DN ) 1 G DN L DN P Q DN ) 1 T U DN ) 2 B C Carbon steel, mat. no 1.035/P235GH DN ) 2 F G DN ) 2 K L DN Q DN U DN B C DN K L DN T U DN F 000 G DN Q DN C DN L DN U Flange norm and pressure rating (All sizes are not available in all pressure ratings) to EN PN16 C PN25 D PN0 E Approval Without approval 0 With approval mark 1 With approval mark and seal 2 Pulse value/ Frequency setup pulse value (pulse width 5 ms) 1 l/pulse l/pulse 3 10 l/pulse 50 l/pulse l/pulse 6 Selection and Ordering data Order-No. Order Code Flowmeter 7 ME Transmitter SONO 3000 CT, IP67 PA, no display, A V AC, 1 current, 1 frequency/pulse, 1 relay, incl. wall mounting kit Country/ Approval-type Neutral / none A Austria / OE01 C 050 B Croatia / HR Q C Czech Republic / TCM 12/ D Denmark / TS (OIML R75) E Finland F Germany / (PTB) G Hungary /TH-7181/1999 H Lathvia J Poland / ZT 597/2003 K Romania / RO 176/98 L Russia / 16373/1 M Switzerland / ZW 138 N Ukraine P Yugoslavia / Q-2-17 Q China Z Q 0 C Slovak Republic Z Q 0 L 1) EN 13 reference value Additional information Please add -Z to Order No. and specify Order code(s) and plain text. Calibration/Verification Verification 2x points, DN DN 80 Verification 2x points, DN DN 00 Verification 2x points, DN DN 1200 Accreditated Siemens EN 5001 calibration DN DN 80 Accreditated Siemens EN 5001 calibration DN DN 00 Accreditated Siemens EN 5001 calibration DN DN 1200 Accreditated DELFT EN 5001 calibration DN DN 80 Accreditated DELFT EN 5001 calibration DN DN 00 Accreditated DELFT EN 5001 calibration DN DN 1200 Tag name plate Stainless steel tag with 12 mm characters, max. 15 characters (add plain text) Self-adhesive plastic tag with 8 mm characters, max. 15 characters (add plain text) Order code D10 D11 D12 D20 D21 D22 D30 D31 D32 Y17 Y18 /190 Siemens FI

SITRANS F flowmeters SITRANS F US. Flowmeter FUE380 with approval. 4/230 Siemens FI Overview

SITRANS F flowmeters SITRANS F US. Flowmeter FUE380 with approval. 4/230 Siemens FI Overview SITRANS F flowmeters Siemens AG 009 Overview The -track flowmeter SITRANS FUE380 comes as battery or mains-powered and is designed to measure water flow in district heating plants, local networks, boiler

More information

Flow Measurement. SITRANS F US Inline. Flowmeter SITRANS FUS380 standard. 4/254 Siemens FI Overview

Flow Measurement. SITRANS F US Inline. Flowmeter SITRANS FUS380 standard. 4/254 Siemens FI Overview Flowmeter SITRANS FUS380 standard Overview Design The 2-track design of SITRANS FUS380 ensures maximum accuracy under short inlet conditions. The flowmeter consists of a flow sensor pipe, transducers/transducer

More information

Flow Measurement SITRANS F US Inline

Flow Measurement SITRANS F US Inline Flowmeter SITRANS FUE80 with CT approval Overview The 2-path flowmeter SITRANS FUE80 comes as battery or mains-powered and is designed to measure water flow in district heating plants, local networks,

More information

SITRANS F flowmeters SITRANS F US. SONOFLO SONO 3000 transmitter. 4/152 Siemens FI Overview

SITRANS F flowmeters SITRANS F US. SONOFLO SONO 3000 transmitter. 4/152 Siemens FI Overview Overview Design The transmitter is available in different enclosure to fit any demands: IP67 enclosure for compact or wall mounting IP00 as a 19 insert IP65 for wall mounting IP65 enclosure in stainless

More information

Flow Measurement SITRANS F US Inline

Flow Measurement SITRANS F US Inline Flowmeter SITRANS FUS80 standard Overview Design The -path design of SITRANS FUS80 ensures maximum accuracy under short inlet conditions. The flowmeter consists of a flow sensor pipe, 4 transducers/transducer

More information

Measurement. SITRANS F US Inline. 3/262 Siemens FI Transmitter SITRANS FUS080/FUE080

Measurement. SITRANS F US Inline. 3/262 Siemens FI Transmitter SITRANS FUS080/FUE080 Overview The transmitter is available in an IP67/NEMA 4X/6 enclosure and is designed for use in the flowmeters series: SONOKIT (1-path or -path) FUS80 (-path) FUE80 (-path) The transmitter FUS080 is always

More information

SITRANS F flowmeters SITRANS F US. Transmitter FUS080. 4/194 Siemens FI

SITRANS F flowmeters SITRANS F US. Transmitter FUS080. 4/194 Siemens FI Overview The transmitter is available in an IP67/NEMA X/6 enclosure and is designed for use in the flowmeters series: SONOKIT (1- or 2-track) FUS380 (2-track) FUE380 (2-track) The transmitter FUS080 is

More information

Flow Measurement SITRANS F M. Flow sensor MAG /49. Overview

Flow Measurement SITRANS F M. Flow sensor MAG /49. Overview Siemens AG 2010 Flow Measurement Overview Mode of operation The flow measuring principle is based on Faraday s law of electromagnetic induction according to which the sensor converts the flow into an electrical

More information

SITRANS F flowmeters SITRANS F US. Transmitter FUS060. Overview

SITRANS F flowmeters SITRANS F US. Transmitter FUS060. Overview Overview Function Displays and keypad Operation of the SITRANS FUS060 transmitter can be carried out using: Keypad and display unit HART communicator PC/laptop and SIMATIC PDM software via HART communication

More information

SITRANS F flowmeters SITRANS F M. Flow sensor MAG /48 Siemens FI Overview

SITRANS F flowmeters SITRANS F M. Flow sensor MAG /48 Siemens FI Overview Siemens AG 2009 Overview Integration The complete flowmeter consists of a flow sensor and an associated transmitter MAG 5000, 6000 or 6000 I. The flexible communication concept USM II simplifies integration

More information

Clamp-on ultrasonic flowmeters have six product families: max. 2% solids

Clamp-on ultrasonic flowmeters have six product families: max. 2% solids System info and selection guide Ultrasonic flowmeters Overview Siemens offers two types of ultrasonic flowmeters, wetted flowmeters and clamp-on flowmeters. This offers the end user the maximum flexibility

More information

SITRANS F US SONOCAL series 3000

SITRANS F US SONOCAL series 3000 s Handbook series 3000 Ultrasonic heat meter and flowmeter The ultrasonic heat meter series 3000 is an ideal combination of a SITRANS F US SONOFLO ultrasonic flowmeter, a energy calculator type SITRANS

More information

UFM 800 W, C Ultrasonic flowmeter for water and wastewater

UFM 800 W, C Ultrasonic flowmeter for water and wastewater KROHNE 08/2000 7.02343.21.00 GR/PRINTO, C Ultrasonic flowmeter for water and wastewater...with weld-in sensors for metal pipelines...withbuilt-on or built-in sensors for open channels Variable area flowmeters

More information

Flow Measurement SITRANS F M

Flow Measurement SITRANS F M Overview Mode of operation The flow measuring principle is based on Faraday s law of electromagnetic induction according to which the sensor converts the flow into an electrical voltage proportional to

More information

SITRANS F US SONOCAL series 3000

SITRANS F US SONOCAL series 3000 s Handbook SITRANS F US SONOCAL series 3000 Ultrasonic heat meter and flowmeter District heating applications Chilled water applications Combined cooling/heating application [ ] Order no.: FDK:521H1087

More information

SITRANS F flowmeters SITRANS F M. Transmitter Transmag 2 with sensor 911/E 4/77. Overview

SITRANS F flowmeters SITRANS F M. Transmitter Transmag 2 with sensor 911/E 4/77. Overview Overview Design The complete flowmeter consists of a flow sensor and an associated transmitter from the Transmag 2 for pulsed alternating field. These are available as remote and compact versions ( 911/E

More information

Flow Measurement SITRANS F M. Transmitter TRANSMAG 2 with sensor 911/E 4/101. Overview

Flow Measurement SITRANS F M. Transmitter TRANSMAG 2 with sensor 911/E 4/101. Overview Siemens AG 2010 Flow Measurement Overview Design The complete flowmeter consists of a flow sensor and an associated transmitter from the TRANSMAG 2 for pulsed alternating field. These are available as

More information

Flow Measurement SITRANS F M

Flow Measurement SITRANS F M Overview Mode of operation The flow measuring principle is based on Faraday s law of electromagnetic induction according to which the sensor converts the flow into an electrical voltage proportional to

More information

SITRANS F M MAGFLO Electromagnetic Flowmeters Explore the Siemens Solution. sitrans f

SITRANS F M MAGFLO Electromagnetic Flowmeters Explore the Siemens Solution. sitrans f SITRANS F M MAGFLO Electromagnetic Flowmeters Explore the Siemens Solution sitrans f s Water and Wastewater MAGFLO for water processes Cost effective solution The MAG 5000 transmitter and MAG 5100 W sensor

More information

Electromagnetic Flow Transmitter

Electromagnetic Flow Transmitter Electromagnetic Flow Transmitter Sensor in solid state technology Working as a transmitter and/or as an On/Off controller Automatic-calibration of full scale: Teach-In Clean in place (CIP) Type can be

More information

Electromagnetic flowmeters and switches DWM 1000/2000

Electromagnetic flowmeters and switches DWM 1000/2000 KROHNE 10/2000 D 20 DW10 02 E GR Electromagnetic flowmeters and switches DWM 1000/2000 Variable area flowmeters Vortex flowmeters Flow controllers Electromagnetic flowmeters Ultrasonic flowmeters Mass

More information

FLOWMETER. Siemens MAG 5000/6000. Overview

FLOWMETER. Siemens MAG 5000/6000. Overview Overview Design The transmitter is designed as either IP67 NEMA 4X enclosure for compact or wall mounting or 19" version as a 19 insert as a base to be used in: 19" rack systems Panel mounting IP65/NEMA

More information

OPTIFLUX 5000 Technical Datasheet

OPTIFLUX 5000 Technical Datasheet OPTIFLUX 5000 Technical Datasheet Electromagnetic flowmeter in flanged version Exceptional long-term stability and accuracy For highly aggressive and abrasive fluids Fully vacuum-resistant with high-tech

More information

IFC 010 Signal Converter

IFC 010 Signal Converter KROHNE 04/2003 7.02347.22.00 GR Signal Converter for electromagnetic flowmeters Easy to install Low-cost signal converter, measuring error < 0.5% of the measured value Easy user-friendly operation Self-monitoring

More information

Magnetic-inductive flow meter. PITe / UMF2. Technical Datasheet. Maintenance-free Nearly no pressure drop Robust design Easy installation and start-up

Magnetic-inductive flow meter. PITe / UMF2. Technical Datasheet. Maintenance-free Nearly no pressure drop Robust design Easy installation and start-up Magnetic-inductive flow meter Technical Datasheet PITe / UMF2 Maintenance-free Nearly no pressure drop Robust design Easy installation and start-up Subject to change without notice 1 Function An electrically

More information

Measuring range: l/h water m³/h air (20 C, bar) Connection: Flange DN 15...

Measuring range: l/h water m³/h air (20 C, bar) Connection: Flange DN 15... Full Metal Variable Area Flow Meter and Counter for Liquids and Gases monitoring analysing BGN Special versions up to 600 bar O Nominal diameter up to DN 150 S2 Measuring range: 0.5-5.0... 13000-130000

More information

ABB MEASUREMENT & ANALYTICS DATA SHEET. Ultrasonic level LST400 Open channel flow transmitter

ABB MEASUREMENT & ANALYTICS DATA SHEET. Ultrasonic level LST400 Open channel flow transmitter ABB MEASUREMENT & ANALYTICS DATA SHEET Ultrasonic level LST400 Open channel flow transmitter 2 ULTRASONIC LEVEL LST400 / OPEN CHANNEL FLOW TRANSMITTER DS/LST400 EN REV. D Measurement made easy Reduced

More information

Level Measurement. Continuous level measurement - Radar transmitters SITRANS LR400 5/229. Overview

Level Measurement. Continuous level measurement - Radar transmitters SITRANS LR400 5/229. Overview Overview Application It provides excellent results on low dielectric media. is available for standard applications and for applications that require explosion proof protection. features robust enclosure,

More information

Technical Specification FLUXUS ADM 8127B

Technical Specification FLUXUS ADM 8127B FLUXUS ADM 8127B Liquid Ultrasonic Flowmeter for Permanent Installation in Hazardous Areas in the Mining Environment FLUXUS ADM 8127B is especially designed for the stationary use in explosive atmosphere

More information

DMH. Magnetic Inductive Flowmeter. for Conductive Fluids

DMH. Magnetic Inductive Flowmeter. for Conductive Fluids Magnetic Inductive Flowmeter for Conductive Fluids measuring monitoring analyzing DMH Measuring Range: 0.29...26.4 to 431.6 43,333 GPM Accuracy: ± 0.3% of Reading ± 0.01% x Q max p max : 580 PSI t max

More information

Level Measurement Continuous level measurement Radar transmitters

Level Measurement Continuous level measurement Radar transmitters Overview Benefits Process Intelligence for advanced signal processing and quick and easy adjustment Self-guided quick start wizard for plug and play startup 2 GHz provides superior reflective properties

More information

OPTIFLUX 5000 Technical Datasheet

OPTIFLUX 5000 Technical Datasheet OPTIFLUX 5000 Technical Datasheet Electromagnetic flowmeter in flanged version Exceptional long-term stability and accuracy For highly aggressive and abrasive fluids Fully vacuum-resistant with high-tech

More information

Level Measurement. Continuous level measurement Radar transmitters SITRANS LR460. 4/258 Siemens FI

Level Measurement. Continuous level measurement Radar transmitters SITRANS LR460. 4/258 Siemens FI Overview The is a -wire, 2 GHz FMCW radar level transmitter with extremely high signal-to-noise ratio and advanced signal processing for continuous monitoring of solids up to 100 m (328 ft). It is ideal

More information

BGN. All Metal Variable Area Flowmeter and Counter. for liquids and gases

BGN. All Metal Variable Area Flowmeter and Counter. for liquids and gases All Metal Variable Area Flowmeter and Counter for liquids and gases monitoring analysing BGN Measuring range: 0.5-5.0... 13000-130000 l/h water 0.015-0.15... 240-2400 m³/h air (20 C, 1.013 bar) Accuracy

More information

Level Measurement. Continuous level measurement - Radar transmitters SITRANS LR400 5/229. Overview

Level Measurement. Continuous level measurement - Radar transmitters SITRANS LR400 5/229. Overview Overview Application It provides excellent results on low dielectric media. is available for standard applications and for applications that require explosion proof protection. features robust enclosure,

More information

Digital flow transmitter for continuous flow measurement

Digital flow transmitter for continuous flow measurement Digital flow transmitter for continuous flow measurement Compact or remote version for DN 06 to 400, PN10 Shows both flow rate and volume (with two totalizers) Automatic-calibration: TEACH-IN Simulation:

More information

SITRANS F flowmeters. SITRANS F M System information MAGFLO electromagnetic flowmeters 4/11

SITRANS F flowmeters. SITRANS F M System information MAGFLO electromagnetic flowmeters 4/11 Overview family are designed for measuring the flow of electrically conductive mediums. Benefits System information FLO Easier to commission for 5000, 6000, 6000 I All FLO pulsed DC feature a unique SENSORPROM

More information

Coriolis Massflowmeter

Coriolis Massflowmeter Coriolis Massflowmeter for liquids and gas measuring monitoring analysing Measuring range: 0-60 kg/h 0-60 000 kg/h water Accuracy: ±0,15 of reading ±zero-point stability pmax: PN40 tmax: -40 +180 C Connection:

More information

SITRANS F flowmeters. SITRANS F R Rotary-piston meters Accessory modules 4/431. Overview. Siemens AG 2009

SITRANS F flowmeters. SITRANS F R Rotary-piston meters Accessory modules 4/431. Overview. Siemens AG 2009 Siemens AG 2009 SITRANS F flowmeters Rotary-piston meters Accessory modules Accessory modules For quantity measurements in conjunction with electromechanical and electronic pulse counters As transmitter

More information

SONOMETER TM 1000 Ultrasonic compact heat meter

SONOMETER TM 1000 Ultrasonic compact heat meter SONOMETER TM 1000 Ultrasonic compact heat meter Description/Application The SONOMETER 1000 is a static compact heat meter with fully electronic measurement based on the ultrasonic principle. It is especially

More information

Flow Switch - 2 programmable thresholds. Stand Alone (Battery) - Battery powered, - 2 totalizers display, - Local flow display,

Flow Switch - 2 programmable thresholds. Stand Alone (Battery) - Battery powered, - 2 totalizers display, - Local flow display, DN 15 - DN 50; PN Advantages / Benefits Easy System integration by Easy LINK provides low cost of ownership Easy commissioning due to multi-language, menu-guided operation TEACH-IN: automatic calibration

More information

LST400 Ultrasonic level / open channel flow transmitter

LST400 Ultrasonic level / open channel flow transmitter Data sheet DS/LST400 EN Rev.C LST400 Ultrasonic level / open channel flow transmitter Measurement made easy Reduced installation cost Easy access terminations Integrated echo display makes for easy troubleshooting

More information

Magnetic Inductive Flowmeter

Magnetic Inductive Flowmeter Magnetic Inductive Flowmeter for conductivity liquids measuring monitoring analysing Measuring range: up to 10 m/s Accuracy: ±1.5% of reading ±0.5% full scale pmax: PN40 tmax: -40 +150 C Connection: flange

More information

INLINE flowmeter for continuous flow measurement

INLINE flowmeter for continuous flow measurement INLINE flowmeter for continuous flow measurement Economic integration in pipe systems without any additional piping 3-wire frequency pulse version to directly interface with PLC s (both PNP and NPN) Connection

More information

Full Metal Variable Area Flowmeter and Counter Model BGF

Full Metal Variable Area Flowmeter and Counter Model BGF Full Metal Variable Area Flowmeter and Counter for horizontal and vertical mounting measuring monitoring analysing BGF OO Measuring range: 10-100... 6000-60000 l/h water 0.3-3.0... 170-1700 m³/h air (20

More information

Electro-Magnetic Flowmeters COPA-XE

Electro-Magnetic Flowmeters COPA-XE Data Sheet Electro-Magnetic Flowmeters COPA-XE 10DX4311 Flowmeter system utilizes a smart microprocessor converter System accuracy of ± 0.5% of rate Field configurable via integral pushbuttons, eliminates

More information

4/11. Overview. Easier service Transmitter replacement requires no programming. SENSORPROM automatically updates all settings after initialization.

4/11. Overview. Easier service Transmitter replacement requires no programming. SENSORPROM automatically updates all settings after initialization. Overview family are designed for measuring the flow of electrically conductive mediums. Benefits Easier commissioning of 5000, 6000, 6000 I All pulsed DC feature a unique SENSORPROM memory unit which stores

More information

WATERFLUX 3070 Technical Datasheet

WATERFLUX 3070 Technical Datasheet WATERFLUX 3070 Technical Datasheet Engineered and manufactured for the water and wastewater industry Highly accurate measurement with extremely short in- and outlet lengths Battery operated, stand alone

More information

NGR. Guided Wave Radar Level Transmitter

NGR. Guided Wave Radar Level Transmitter Guided Wave Radar Level Transmitter measuring monitoring analyzing NGR For Liquids Operates Independent of Density, Temperature, Pressure, Humidity, and Conductivity Standard Measuring Length: 6. Ft (Longer

More information

Level Measurement Continuous level measurement Radar transmitters

Level Measurement Continuous level measurement Radar transmitters Overview Configuration Mounting on a nozzle is a 2-wire 25 GHz pulse radar level transmitter for continuous monitoring of solids and liquids in storage vessels including extreme levels of dust and high

More information

Electromagnetic flowmeters Transmitter types MAG 5000, MAG 6000

Electromagnetic flowmeters Transmitter types MAG 5000, MAG 6000 s Operating Manual Edition 05/2006 - Revision 05 SITRANS F M MAGFLO Electromagnetic flowmeters Transmitter types MAG 5000, MAG 6000 [ ] Technical Documentation (handbooks, instructions, manuals etc.) on

More information

Type PLC Fitting. Valve for Continuous control. Diaphragm valve. Output

Type PLC Fitting. Valve for Continuous control. Diaphragm valve. Output Digital Inductive conductivity transmitter Optimal solution for conductivity measurements in difficult fluids (polluted, dirty,...) PEEK/PPA version for CIP applications Large range of process connections

More information

INSERTION paddle wheel flowmeter for continuous flow measurement

INSERTION paddle wheel flowmeter for continuous flow measurement INSERTION paddle wheel flowmeter for continuous flow measurement Economic integration in pipe systems without any additional piping 3-wire frequency pulse version to directly interface with PLC s (both

More information

Flow Measurement SITRANS F VA. SITRANS FVA250 variable area meter. 4/382 Siemens FI Overview

Flow Measurement SITRANS F VA. SITRANS FVA250 variable area meter. 4/382 Siemens FI Overview Overview Design and mode of operation Like the other units in the range, the SITRANS FVA250 operates according to the variablearea flow tube principle: the flowing medium lifts the conical float in the

More information

INLINE flowmeter for continuous flow measurement

INLINE flowmeter for continuous flow measurement INLINE flowmeter for continuous flow measurement Economic integration in pipe systems without any additional piping 3-wire frequency pulse version to directly interface with PLC s (both PNP and NPN) Connection

More information

Servo Gauge 854 XTG. Global Experience. Locally Applied. Cut costs, not repeatability.

Servo Gauge 854 XTG. Global Experience. Locally Applied. Cut costs, not repeatability. Servo Gauge 854 XTG Cut costs, not repeatability. Honeywell Enraf s 854 XTG servo gauge is a high performance alternative to other tank level measurement technologies such as radar tank level gauges. It

More information

TME. Coriolis Massflowmeter. for liquids and gases kg/h kg/h water. p max. : PN40 t max : C

TME. Coriolis Massflowmeter. for liquids and gases kg/h kg/h water. p max. : PN40 t max : C Coriolis Massflowmeter for liquids and gases measuring monitoring analysing TME OMeasuring O range: 0-60 kg/h 0-60000 kg/h water O O Accuracy: ±0.15 of reading ± zero-point stability OO p max : PN40 t

More information

KFS-EM. Overall length. Al. PTFE coated Alu, painted Al. coated Methacrylate / acrylic nitrite

KFS-EM. Overall length. Al. PTFE coated Alu, painted Al. coated Methacrylate / acrylic nitrite KFS Flap Flow Meter KFS suitable for H, acids, alkalis and gases spring-loaded horizontal or vertical flow direction low pressure loss mainly viscosity independent optional threshold value contacts optional

More information

Digital inductive conductivity transmitter

Digital inductive conductivity transmitter Digital inductive conductivity transmitter Optimal solution for conductivity measurements in difficult fluids (polluted, dirty,...) PEEK/PPA version for CIP applications Large range of process connections

More information

SITRANS F flowmeters. SITRANS F M System information MAGFLO electromagnetic flowmeters. 4/18 Siemens FI

SITRANS F flowmeters. SITRANS F M System information MAGFLO electromagnetic flowmeters. 4/18 Siemens FI Function All are based on Faraday s law of induction: U M = B v d k U M = Measured voltage induced in the medium perpendicular to the magnetic field and the flow direction. The voltage is tapped at two

More information

Digital flowmeter for continuous flow measurement

Digital flowmeter for continuous flow measurement 8025 Flowmeter INSERTION Digital flowmeter for continuous flow measurement Compact or remote version for DN06 to DN400, PN10 Displays both flow rate and volume (with two totalizers) On site calibration

More information

INLINE flowmeter for continuous flow measurement

INLINE flowmeter for continuous flow measurement INLINE flowmeter for continuous flow measurement Economic integration in pipe systems without any additional piping 3-wire frequency pulse version to directly interface with PLC s (both PNP and NPN) Connection

More information

Ultrasonic level transmitter, non-contact

Ultrasonic level transmitter, non-contact Ultrasonic level transmitter, non-contact Type 8175 can be combined with... Compact, remote versions for level measurement up to 10 m Multi language menu control Interference echo filter Automatic calibration:

More information

Digital flowmeter for continuous flow measurement

Digital flowmeter for continuous flow measurement 8025 Flowmeter INSERTION Digital flowmeter for continuous flow measurement Compact or remote version for DN06 to DN400, PN10 Displays both flow rate and volume (with two totalizers) On site calibration

More information

Technical specification FLUXUS F401 H2O

Technical specification FLUXUS F401 H2O Technical specification Ultrasonic flowmeter for water Portable, very robust and easy-to-use ultrasonic flowmeter for the water and wastewater industry Features Very high bi-directional measuring accuracy

More information

Coriolis Mass Flow Meter Model TM

Coriolis Mass Flow Meter Model TM Coriolis Mass Flow Meter for liquids and gas measuring monitoring analysing TM S5 Measuring range: 0-0.8 kg / h 0-65000 kg / h water Accuracy: ± 0.1 of reading ± zero-point stability (liquids) p max :

More information

VersaFlow Ultrasonic clamp-on Flowmeter Technical Datasheet. Specification. Applications. Highlights. Industries. 34-VF September 2009

VersaFlow Ultrasonic clamp-on Flowmeter Technical Datasheet. Specification. Applications. Highlights. Industries. 34-VF September 2009 VersaFlow Ultrasonic clamp-on Flowmeter Technical Datasheet 34-VF-03-14 September 2009 Specification Clamp-on technology HONEYWELL S VERSAFLOW stands for continuity and long term reliability. Flow measurement

More information

ULTRAFLOW TS PTB. Application. Ultrasonic flow sensor. Compact design. Static meter with no moving parts. Large dynamic range.

ULTRAFLOW TS PTB. Application. Ultrasonic flow sensor. Compact design. Static meter with no moving parts. Large dynamic range. Ultrasonic flow sensor Compact design D a t a s h e e t Static meter with no moving parts Large dynamic range No wear Exceptionally accurate Longevity TS 27.01 113 OIML R75 Application TS 27.01 109 DS/EN

More information

TIDALFLUX 2300 F Technical Datasheet

TIDALFLUX 2300 F Technical Datasheet Technical Datasheet Electromagnetic flow sensor for partially filled pipes Measurement in partially filled pipes up to DN1600 / 64" Patented, non-contact level measurement Measurement possible down to

More information

KMS305W. ManuFlo Page 1 MANU ELECTRONICS PTY LTD Flow Measurement Products. Electromagnetic Wafer Flowmeters with S300 display

KMS305W. ManuFlo Page 1 MANU ELECTRONICS PTY LTD Flow Measurement Products. Electromagnetic Wafer Flowmeters with S300 display Electromagnetic Wafer Flowmeters with S300 display for corrosive chemicals/acids & slurries (sizes: 2.5mm to 100mm) 0BFEATURES: For aggressive chemicals, slurries, oxides, grouts & dosing applications

More information

Design and applications

Design and applications Design and applications The measuring device operates largely independent of viscosity and is suitable for indicating the flow rate of water, acids, alkaline solutions and gases. Every device is calibrated

More information

SITRANS F flowmeters. SITRANS F System information MAGFLO electromagnetic flowmeters 4/9

SITRANS F flowmeters. SITRANS F System information MAGFLO electromagnetic flowmeters 4/9 Overview MAGFLO family MAGFLO electromagnetic are designed for measuring the flow of electrically conductive mediums. The patented MAGFLO Verificator guarantees accurate measurement and simple verification.

More information

Target disk flowmeter for liquids and gases

Target disk flowmeter for liquids and gases Target disk flowmeter for liquids and gases Metallic, simple and robust construction Available for all flow directions Suitable for extreme pressure and temperature conditions Low pressure drop Straight

More information

Digital conductivity transmitter

Digital conductivity transmitter Digital conductivity transmitter Compact version with integrated conductivity electrodes Remote version with seperated transmitter for short (15 ft.) or long (1500 ft.) distance Commissioning is easy due

More information

WESAN WP E ELECTRONIC METER WOLTMAN

WESAN WP E ELECTRONIC METER WOLTMAN APPLICATION Fully electronic bulk water meter for measuring the flow (cold water up to 30 C) in supply lines with high flow at low pressure loss. Highly accurate recording of all billing data. FEATURES

More information

The transducer component converts the measured signal and displays the actual value.

The transducer component converts the measured signal and displays the actual value. Digital inductive conductivity transmitter System Integration Provides low Total Cost of Ownership PEEK/PPA version for CIP applications TEACH IN and SIMULATION Function Approval PVDF Version PEEK Version

More information

Coriolis Massflowmeter

Coriolis Massflowmeter Coriolis Massflowmeter for liquids and gas measuring monitoring analysing Measuring range: 0-60 kg/h 0-60 000 kg/h water Accuracy: ±0,15 of reading ±zero-point stability pmax: PN40 tmax: -40 +180 C Connection:

More information

TUR. Turbine Wheel Flowmeter. Plastic Model for Liquids. Measuring Ranges: GPM or GPM (Water)

TUR. Turbine Wheel Flowmeter. Plastic Model for Liquids. Measuring Ranges: GPM or GPM (Water) Turbine Wheel Flowmeter Plastic Model for Liquids measuring monitoring analyzing TUR TUR with Transmitter TUR with ADI-1 Measuring Ranges: 5.3...88 GPM or 11...440 GPM (Water) Measuring Accuracy: ± 1%

More information

600T Series Transmitters Model 653L Electronic temperature transmitter (PC programmable for RTD and resistance) Specification Sheet

600T Series Transmitters Model 653L Electronic temperature transmitter (PC programmable for RTD and resistance) Specification Sheet Specification Sheet 600T Series Transmitters Model 65L Electronic temperature transmitter (PC programmable for RTD and resistance) High flexibility and wide rangeability Primary element and calibration

More information

Model Sono-Trak Transit Time

Model Sono-Trak Transit Time Model Sono-Trak Transit Time Ultrasonic Flow Meter Engineered for performance excellence, the Sono-Trak Transit Time ultrasonic meter combines non-invasive, bi-directional measurement with advanced ultrasonic

More information

SALES SERVICE +358 (0)

SALES SERVICE +358 (0) SALES SERVICE +358 (0)17 262 3555 info@econosto.fi ADCATROL ELECTRO-PNEUMATIC POSITIONERS PE 986 (ATEX) DESCRIPTION The ADCATROL PE986 positioner requires an input signal of 4 20 ma for proportional control

More information

600T Series Transmitters. Specification Sheet. Model 653T Electronic temperature transmitter (PC programmable)

600T Series Transmitters. Specification Sheet. Model 653T Electronic temperature transmitter (PC programmable) Specification Sheet 600T Series Transmitters Model 65T Electronic temperature transmitter (PC programmable) High flexibility and wide rangeability Single transmitter accepts RTD/THC/mV/ohm Galvanically

More information

SITRANS F C. Flowmeter SITRANS FC430 3/151. Technical specifications. Overview

SITRANS F C. Flowmeter SITRANS FC430 3/151. Technical specifications. Overview Flow Measurement Flowmeter SITRANS FC40 Overview The complete flowmeter system SITRANS FC40 can be ordered for standard, hygienic or NAMUR service. All versions can be ordered for CT service, according

More information

OPTIFLUX 1000 Technical Datasheet

OPTIFLUX 1000 Technical Datasheet OPTIFLUX 1000 Technical Datasheet Electromagnetic flow sensor in sandwich design Lightweight and compact Excellent price performance ratio Quick and easy to install The documentation is only complete when

More information

Pressure Transmitter Type AKS 32 and AKS 33 REFRIGERATION AND AIR CONDITIONING. Technical leaflet

Pressure Transmitter Type AKS 32 and AKS 33 REFRIGERATION AND AIR CONDITIONING. Technical leaflet Pressure Transmitter Type AKS 32 and AKS 33 REFRIGERATION AND AIR CONDITIONING Technical leaflet 2 RD.5G.H4.02 Danfoss A/S (IC-MC/mr), 09-2004 Introduction AKS 32 and AKS 33 are pressure transmitters that

More information

ma output signal with transmitter module. - Adjustable frequency output signal with pulse divider module

ma output signal with transmitter module. - Adjustable frequency output signal with pulse divider module / - ; 0 PSI Advantages / Benefits Wireless easy mounting and dismounting of sensor head by a Turn & Lock technique 3-wire Hall version to interface directly with PLC's (both NPN and PNP) Easy to connect:

More information

SONO 1500 CT Ultrasonic flow sensor

SONO 1500 CT Ultrasonic flow sensor Data sheet SONO 1500 CT Ultrasonic flow sensor Description/Application MID examination certificate no.: DE-09-MI004-PTB011 The SONO 1500 CT is an ultrasonic flow sensor especially designed for heating,

More information

Online data sheet FLOWSIC600 GAS FLOW METERS

Online data sheet FLOWSIC600 GAS FLOW METERS Online data sheet FLOWSI600 F H I J K L M N O P Q R S T US Ordering information Type FLOWSI600 Part no. On request In accordance with rticle 2 (4), this product does not fall within the scope of RoHS directive

More information

BATCHFLUX 5500 C Technical Datasheet

BATCHFLUX 5500 C Technical Datasheet BATCHFLUX 5500 C Technical Datasheet Electromagnetic flowmeter for volumetric filling machines High-stability ceramic measuring tube, therefore extremely long-term stability Optimum hygienic design Only

More information

FLOMID FX Electromagnetic Flowmeter

FLOMID FX Electromagnetic Flowmeter FLOMID FX Electromagnetic Flowmeter Working pressure manufacturing according to PED 97/23/CE (Lloyd s Register Certificate Nº 031) Introduction Modular design in two versions: Compact, sensor and electronics

More information

OPTITEMP TT 20 Technical Datasheet

OPTITEMP TT 20 Technical Datasheet OPTITEMP TT 20 Technical Datasheet Analog PC-programmable two-wire transmitters for Pt100 Efficient PC-configuration without recalibration Very stable output Very fast response time The documentation is

More information

MaxxFlow HTC Flow Measurement for Dry Bulk Solids

MaxxFlow HTC Flow Measurement for Dry Bulk Solids EN MaxxFlow HTC Flow Measurement for Dry Bulk Solids Manufactured by Product Information www.onthelevel.com MaxxFlow HTC MaxxFlow HTC MaxxFlow HTC Product Information Use The MaxxFlow HTC was developed

More information

SITRANS F flowmeters. SITRANS F M System information MAGFLO electromagnetic flowmeters 4/11

SITRANS F flowmeters. SITRANS F M System information MAGFLO electromagnetic flowmeters 4/11 Overview family are designed for measuring the flow of electrically conductive mediums. Benefits SITRANS F flowmeters System information FLO Easier to commission All FLO feature a unique SENSORPROM memory

More information

ULTRAFLOW TS Application OIML R75 DS/EN 1434

ULTRAFLOW TS Application OIML R75 DS/EN 1434 ULTRAFLOW Ultrasonic flow meter Compact design Static meter with no moving parts Large dynamic range No wear Exceptionally accurate Longevity TS 27.01 113 OIML R75 TS 27.01 109 DS/EN 1434 Application ULTRAFLOW

More information

EN-2018 MAGNETIC FLOW METERS

EN-2018 MAGNETIC FLOW METERS EN-2018 MAGNETIC FLOW METERS www.meatest.com 1 MEASURING PRINCIPLE Having no moving or mechanical parts in the flow profile electromagnetic flow meters cause no pressure drop, are virtually maintenance

More information

E l e c t r o m a g n e t i c f l o w m e t e r s

E l e c t r o m a g n e t i c f l o w m e t e r s E l e c t r o m a g n e t i c f l o w m e t e r s P r o v e n A N D R e l i a b l e F l o w M e a s u r e m e n t 2 MJK MagFlux flow meters combine high accuracy, stability and low maintenance. Without

More information

Advanced instrumentation solutions crafted with highest precision

Advanced instrumentation solutions crafted with highest precision www.adeptfluidyne.com Advanced instrumentation solutions crafted with highest precision Working Principle The Transit Time Flowmeter utilises two transducers that function as both ultrasonic transmitters

More information

prosonic T FMU230, FMU231

prosonic T FMU230, FMU231 Technical Information prosonic T FMU230, FMU231 Ultrasonic Level Measurement Compact transmitters for non-contact level measurement of fluids and coarse bulk materials Application The compact transmitters

More information

RTD Temperature Sensor omnigrad T -TSM 480, TR 480. Hygienic RTD sensor with Pt 100, class A TSM 480 with electronics programmable via PC

RTD Temperature Sensor omnigrad T -TSM 480, TR 480. Hygienic RTD sensor with Pt 100, class A TSM 480 with electronics programmable via PC Technical Information TI 273T/02/en 60021667 RTD Temperature Sensor omnigrad T -TSM 480, TR 480 Hygienic RTD sensor with Pt 100, class A TSM 480 with electronics programmable via PC Application The Omingrad

More information

OPTISONIC 7300 Technical Datasheet

OPTISONIC 7300 Technical Datasheet OPTISONIC 7300 Technical Datasheet Ultrasonic gas flowmeter Wide application range No moving parts and no pressure loss Complete solution for gasflow measurement KROHNE CONTENTS OPTISONIC 7300 1 Product

More information