Measurement. SITRANS F US Inline. 3/262 Siemens FI Transmitter SITRANS FUS080/FUE080
|
|
- Loren Singleton
- 5 years ago
- Views:
Transcription
1 Overview The transmitter is available in an IP67/NEMA 4X/6 enclosure and is designed for use in the flowmeters series: SONOKIT (1-path or -path) FUS80 (-path) FUE80 (-path) The transmitter FUS080 is always ordered as part of a complete flowmeter system. It can be manually ordered separately as spare part preprogrammed with the given sensor data. SITRANS FUS080 is a transit time based transmitter designed for ultrasonic flow metering with any sensor in the FUS inline series SONOKIT, FUS80 and FUE80 up to DN 100. The ultrasonic flowmeter transmitter SITRANS FUS080 comes as battery or mains powered version.the SITRANS FUS080 is designed to measure flow water applications. The SONOKIT retrofit flowmeter series are shown from page /86. The standard flowmeter series SITRANS FUS80 is described from page /97. The type approved flowmeter series for flow metering in energy meter custody transfer systems are named SITRANS FUE80 - see page /0. Benefits Battery-powered up to 6 years 115/0 V mains-powered with back-up battery option in case of mains power failure Fast measuring frequency 15 Hz/0.5 Hz (0 V AC/Battery) Easy one button straight forward display IrDA optical interface for local communication -path measuring principle for optimum accuracy Compact or remote mounting Measures on all district water qualities and water conductivities No pressure drop Long-term stability galvanic isolated digital outputs for easy connection to a calculator (potential free) 1 analog 4 to 0 ma output Bidirectional measurement, with totalizers and outputs Dynamic range Q i (min) : Q s (max) up to 1:400 Compact version with triax cables for highest EMC-protection Application The main application for flowmeters with the transmitter SITRANS FUS080 is measurement of water flow in district heating plants, local networks, boiler stations, substations, chiller plants, irrigations plants and other general water applications. Design The transmitter type SITRANS FUS080 is designed with fiberglass reinforced polyamide enclosure for remote or compact installation in normal areas. The remote versions are available with up to 0 meter distance from flowmeter to transmitter. When ordering as a compact version in the series FUS80 and FUE80 the transducer cables are pre-mounted at the sensor. Integration The flowmeter pulse output is often used as input for an energy meter or as input for digital systems for remote reading. SITRANS FUS80 has two pulse outputs, with functions that can be individually selected. The settings of the transmitter, eg. flow and pulse output rate, are defined when ordering the complete flowmeter. If the flowmeter forms part of an energy meter system for custody transfer, no further approvals are needed, except eventually local approvals on the flowmeter. Technical specifications Input Measurement Measuring rate Battery mode Mains supply Back-up mode Flow rate Output Max. pulse frequency Pulse value and length Output A function Output B function Pulse value A and B Pulse length (depending on Q max by DN selection) Alarm indication Analog output Flow by measuring the transit time difference of ultrasonic signals through ultrasonic transducers in the sensor pipes. Supporting of 1-path or -path sensors in sizes DN measuring on water. 0.5 Hz Up to 15 Hz 0.5 Hz (at mains supply drop) m/s ( ft/s), bidirectional flow metering pulse or status outputs (A and B), individual galvanically isolated MOS relay outputs, passive mode, max. 5 V AC/DC, max. 50 ma 100 Hz at Q s (Q max) Selectable with the ordering of the flowmeter Pulse: forward, reverse, forward net, reverse net (preset: forward) Pulse: forward, reverse, forward net, reverse net (preset: forward) or alarm indication or call-up indication (preset: alarm) 0.1 l/p, 0.5 l/p, 0.5 l/p, 1 l/p,.5 l/p, 10 l/p, 5 l/p, 50 l/p, 100 l/p, 50 l/p, 500 l/p, 1 m /p,.5 m /p, 5 m /p, 10 m /p, 5 m /p, 50 m /p, 100 m /p, 50 m /p, 500 m /p, m /p 5, 10, 0, 50, 100, 00, 500 ms (standard 5 ms) Path 1 (F1), path (F) internal, failure (F, F4), powers supply warning or low battery indication (F5), Q max overflow (F6), pulse overflow (F7, F8), internal data logger warning (F9) Passive current output ma Data span pre-selectable depending on pipe size /6 Siemens FI
2 Rated operation conditions Ambient conditions Ambient temperature Operation Storage Enclosure rating Electromagnetic compatibility Emitted interference Immunity MID approved (FUE80 series) Mechanical vibration Weight of transmitter Design Enclosure material Wall mounting kit Sensor cable Display and controls Display Resolution C( F)(MID version: max. +55 C (11 F)) C( F) (battery included) IP67/NEMA 4X/6 to EN 6059 and DIN To EN 55011/CISPR-11 To EN/IEC (Industry) Environment class E and M1 g, Hz sinusoidal in all directions according to IEC Approx. 1.5 kg (. lb) Fibre-glass reinforced polyamide, light gray color IP67/NEMA 4X/6 terminal box for the wall mounting of the transmitter, fiber-glass reinforced polyamide with stainless steel bracket, cable glands entries: x M0 or PG 1.5 for power supply and outputs and x M0 or PG 1.5 for the sensor cables, glands (supply and outputs and double cable entries for sensor cables) are included. Coaxial cable sets for remote transmitter up to 0 m (98.4 ft) long transducer cable, 75 impedance, cables sets are prepared for the connection to the sensors Triax cables for integral version LCD, 8 digits, additional digits and symbols for status information Totalized information can be displayed with 1, or decimals or automatic adjustment (default) Display setting Flow unit: Preset: m /h Volume unit: Preset: m Push button Communication (IrDA optical eye) Power supply Battery Mains Power consumption Mains version One push button for menu selection and display information IrDA optical communication and control interface with Modbus RTU protocol for read or write transmitter settings and data via PC and PDM tool D-cell battery pack,.6 V LiSOCI (Lithium Thionyl Chloride, 4 Ah), replaceable, life- and workingtime up to 6 years V AC ( Hz) or V AC ( Hz) with D-cell single battery backup,.6 V LiSOCI (Lithium Thionyl Chloride, 17 Ah), replaceable, life time up to 8 years Approx..5 VA SONOKIT, FUS80, FUE80 The flow values and settings are predefined according to dimension selection. The transmitter settings are changeable by using the SW tool PDM (for FUE80 series some of the setting are only readable, restriction of the approval requirements). Accuracy/Error in measurement: (at reference conditions for FUS80 and FUE80 series, SONOKIT series will differ in the accuracy) Pulse output % of measured value at m/s or - 0.5/V [m/s] % of measured value at flow < 0.5 m/s Repeatability 0.5 % of measured value at m/s Reference conditions - Process temperature and ambient temperature: 5 C 5 C (77 F 9 F) - Transmitter warming-up time 0 min. - Installation conditions of the sensor: Upstream section > 10 x DN and downstream section > 5 DN [%] [%] Type accuracy limits FUS FUE80 - admissible limits according to OIML R 75 class FUE80 - admissible limits according to EN 144 class [m/s] 10 [ft/s] [m/s] 10 [ft/s] Siemens FI /6
3 Output configuration Current output.6 ma 0.5 ma 0 ma ma 4 ma.6 ma -100% Cut-off 100% Q PR [s] = 1 PF [Hz] Upper alarm limit Upper current limit Upper current scaling point Lower current scaling point Lower alarm limit Pulse volume: output A/B configured as volume per pulse, calculated on forward/reverse or net forward/reverse flow. The volume per pulse is free scaleable (via PDM software). Bidirectional flow.6 ma 0.5 ma 0 ma ma Alarm output On Alarm status Error No error Pulse output B can be used as stated above or as alarm or callup function. Call-up output Off On Off 4 ma.6 ma Positive flow -100% Cut-off Upper alarm limit Upper current limit Upper current scaling point Lower current scaling point Lower alarm limit 100% Q Call-up reset Call-up status On Off.6 ma 0.5 ma 0 ma ma Call-up: the call-up output is active until manually reset by use of PDM tool. The call-up function is activated when an alarm is activated. 4 ma.6 ma -100% Cut-off 100% Q Upper alarm limit Upper current limit Upper current scaling point Lower current scaling point Lower alarm limit Negative flow /64 Siemens FI
4 Sensor coaxial cable for SONOKIT series with FUS080 Coaxial cable Standard coaxial cable (75 ) Outside diameter Length Ø 5.8 mm 15, 0 m (49., 98.4 ft) between sensor and transmitter Material (outside Black PE jacket) Ambient temperature C ( F) Sensor coaxial cable for FUS80/FUE80 series Coaxial cable High temperature coaxial cable (75 ) Outside diameter Length Material (outside jacket) With special designed glands for connection in the sensor/transducer Ø 5.1 mm (first 0. m (0.98 ft) part to the transducer), Ø 5.8 mm (for remaining cable to the transmitter black holt melt junction part between (Ø 16 mm, length 70 mm) Up to 0 m (98.4 ft) between sensor and transmitter Brown PTFE (0. m (9.84 ft) part) and black PE (for remaining cable) Ambient temperature C ( F) (brown PTFE transducer part) and C ( F) (black PE for remaining transmitter cable part) Siemens FI /65
5 Transmitter FUS080 operating instructions, accessories and spare parts Operating instructions Spare part transmitter for FUE80 approved systems (7ME410) (only with MID approval marks, no MID verification only a complete flowmeter can be MID-verified, i.e. sensor together with the transmitter) for use with SONOKIT English A5E integrated in FUS/FUE80 English A5E German A5E All literature is available to download for free, in a range of languages, at Accessories Sun lid for FUS080 transmitter A5E08485 (frame and lid) Brace (holder) for optical IrDA eye IrDA infrared interface adapter with USB for data acquisition with 1. m (.9 ft) cable A5E FDK:087L416 Process Device Manager SIMATIC PDM SIMATIC PDM Details about the SIMATIC PDM tool can be found on page 8/5, chapter "Communication and Software" See page 8/1, chapter "Communication and Software" Spare parts A spare part transmitter can be ordered for a specific system. In the description of the following spare part transmitters the related transmitter found on the device silver front label is noted. Spare part transmitter for FUS80 systems (7ME400) FUS080 transmitter.6 V A5E battery (no battery included, to be ordered separate) as spare part transmitter for FUS80 flowmeter series. Transmitter Article No. 7ME450-0AA10-AA0 FUS080 transmitter.6 V A5E07905 battery (battery included) as spare part transmitter for FUS80 flowmeter series 1). Transmitter 7ME450-0AA0-AA0 FUS080 transmitter 0 V mains A5E as spare part transmitter for FUS80 flowmeter series. Transmitter 7ME450-0AA0-AA0 FUS080 transmitter 0 V mains A5E with backup-battery as spare part transmitter for FUS80 flowmeter series. Transmitter Article No. 7ME450-0AA40-AA0 When ordering: Inform on flowmeter and flowmeter serial no. (e.g. 7ME400-xxxxx-xxxx-Z, XX... and xxxxxxhxxx) FUE080 transmitter.6 V battery A5E (no battery included, to be ordered separate) as spare part transmitter for FUE80 flowmeter series. Transmitter Article No. 7ME450-0AA10-AB0 FUE080 transmitter.6 V A5E battery (battery included) as spare part transmitter for FUE80 flowmeter serie.s 1). Transmitter 7ME450-0AA0-AB0 FUE080 transmitter 0 V A5E07459 mains as spare part transmitter for FUE80 flowmeter series. Transmitter 7ME450-0AA0-AB0 FUE080 transmitter 0 V A5E mains with backup-battery as spare part transmitter for FUE80 flowmeter series. Transmitter 7ME450-0AA40-AB0 When ordering: Inform on flowmeter and flowmeter serial no. (e.g. 7ME410-xxxxx-xxxx-Z, XX... and xxxxxxhxxx) Spare part transmitter for SONOKIT systems (7ME10/7ME0) FUS080 transmitter.6v battery (no battery included, to be ordered separate) as spare part transmitter for SONOKIT flowmeters. Transmitter Article No. 7ME450-0AA10-AA0 FUS080 transmitter.6v battery (battery included) as spare part transmitter for SONOKIT flowmeters 1). Transmitter 7ME450-0AA0-AA0 FUS080 transmitter 0V mains as spare part transmitter for SONOKIT flowmeters. Transmitter 7ME450-0AA0-AA0 FUS080 transmitter 0V mains with backup-battery as spare part transmitter for SONOKIT flowmeters. Transmitter 7ME450-0AA40-AA0 1) A5E A5E A5E A5E When ordering: Inform on flowmeter and flowmeter serial no. (e.g. 7ME0-xxxxx-xxxx-Z, XX... and xxxxxxhxxx) Lithium batteries are subject to special transportation regulations according to United Nations "Regulation of Dangerous Goods, UN 090 and UN 091". Special transport documentation is required to observe these regulations. This may influence both transport time and costs. /66 Siemens FI
6 FUS080 transmitter for FUS880 retrofit systems, USA version, incl. wall-mounting kit, transducers and pcs. 60 ft (0 m) of cables. Label, 0: Siemens FUS080 transmitter; Diameter, 0A: None; Wall Thickness, A: None; Pipe Material, 0: No Pipe; Track configuration, 1: 1-Track; Region version, : USA: AcFt,CFS; Transmitter, D: FUS080,IP67, Battery, Remote, unit label; Template, A: None; Transducer coax cable, 4: 0 m with gland FUS080 transmitter for FUS880 retrofit systems, USA version, incl. wall-mounting kit, 4 transducers and 4 pcs. 60 ft (0 m) of cables: Label, 0: Siemens FUS080 transmitter; Diameter, 0A: None; Wall Thickness, A: None; Pipe Material, 0: No Pipe; Track configuration, : -Track (X-Configuration); Region version, : USA: AcFt,CFS; Transmitter, D: FUS080,IP67, Battery, Remote,unit label; Template, A: None; Transducer coax cable, 4: 0 m with gland Spare part transmitter for FUS880 retrofitting systems (7ME440) Sparepart FUS080 A5E transmitter.6 V, incl..6v dual batterie pack, USA version Transmitter : 7ME450-0AA0-1CA0: Label, 0: Siemens FUS080 transmitter; Version, 0: Without connection box; Enclosure, A: IP67/NEMA 4X/6; Code A: Standard; Supply Voltage, :.6V DC battery; Ex. Approval, 0: no Ex approval; Display, 1: With display and unit label; Region version, C: USA: AcFt,CFS; Application, A: Standard FUS080 (for SITRANS Retrofit - 7ME44); Code, 0: Standard 7ME440-0AA01-DA4 7ME440-0AA0-DA4 Internal battery pack, one set of D-cell (.6 V 4 Ah) 1) 1 pc. pack 4 pcs. pack Single battery back-up to main supply (17 Ah) 1) Battery cover for transmitter FUS080 PG 1.5 cable gland set for FUS080 power and output connection, black PA plastic, pcs. cables Ø mm (0.4" ") C ( F) PG 1.5 cable gland set (two cable entries) for FUS080 sensor connection, black PA plastic, pcs. cables Ø mm (0.4" ") C ( F) A5E A5E A5E06799 A5E FDK:08G08 A5E SITRANS FUS/FUE80 wall A5E mounting kit for remote transmitter mounting, including connection plate (DN DN 100/"... 48") SITRANS FUS/FUE80 terminal box for compact transmitter mounting, including connection plate, (bronze sensors only, DN DN 80/"... ") SITRANS FUS/FUE80 terminal box for compact transmitter mounting, including connection plate, (steel sensors only, DN DN 100/4"... 48") FUS080 display and keypad with Siemens logo FUS080 display and keypad neutral (without logo) A5E A5E A5E A5E1471 1) Lithium batteries are subject to special transportation regulations according to United Nations "Regulation of Dangerous Goods, UN 090 and UN 091". Special transport documentation is required to observe these regulations. This may influence both transport time and costs. Downloads for DEVICE description FUE80 Siemens FI /67
7 Sensor cables for FUS80/FUE80 flowmeters DN 50 to 80 flowmeters Coaxial cable for FUS080; with 0. m brown PTFE high temp. transducer part, max. 00 C (9 F) and black PVC for remaining transmitter part, max. 70 C (158 F); impedance 75 5 m (16.4 ft) cable set (4 pcs.) A5E for DN DN 80 ("... ") remote mounting 10 m (.8 ft) cable set A5E (4 pcs.) for DN DN 80 ("... ") remote mounting 0 m (65.6 ft) cable set A5E (4 pcs.) for DN DN 80 ("... ") remote mounting 0 m (98.4 ft) cable set A5E (4 pcs.) for DN DN 80 ("... ") remote mounting 0.5 m (1.64 ft) cable set A5E (4 pcs.) for DN DN 80 ("... ") for compact version of FUS80/FUE80 DN 100 to 100 flowmeters Coaxial cable for FUS080; with 0. m brown PTFE high temp. transducer part, max. 00 C (9 F) and black PVC for remaining transmitter part, max. 70 C (158 F); impedance 75 5 m (16.4 ft) cable set (4 pcs.) for DN DN 100 (4"... 48") remote mounting 10 m (.8 ft) cable set (4 pcs.) for DN DN 100 (4"... 48") remote mounting 0 m (65.6 ft) cable set (4 pcs.) for DN DN 100 (4"... 48") remote mounting 0 m (98.4 ft) cable set (4 pcs.) for DN DN 100 (4"... 48") remote mounting 1 m (.8 ft) cable set (4 pcs.) for DN DN 100 (4"... 48") for compact version of FUS80/FUE80 A5E A5E A5E A5E A5E Sensor cables for SONOKIT flowmeter with FUS m (49. ft) cable set A5E ( pcs.) remote mounting with SONOKIT flowmeters 0 m (98.4 ft) cable set A5E ( pcs.) remote mounting with SONOKIT flowmeters Sensor cables for FUS880 retrofitting systems (7ME440) Coaxial cable with transducer connection for use in FUS880 and SONO 00 sensors; with 0. m brown PTFE high temperature transducer part, max. 00 C (9 F) and black PVC for the remaining transmitter part, max. 70 C (158 ºF); cable impedance x 10 m (.8 ft) FDK:085L400 1 x 0 m (65.6 ft) FDK:085L401 1 x 0 m (98.4 ft) FDK:085L40 Transducer spare part set of FDK:087H007 two transducers with gaskets for STRANS FUS880 retrofitting systems /68 Siemens FI
8 Dimensional drawings FUS080 transmitter IP67/NEMA 4X/6, wall mounting and compact mounting 71 (.8) 155 (6.10) 6 (0.4) 1 (5.4) Ø8 (0.) Ø1 (0.5) Ø8 (0.) 1 (0.5) 1 (0.5) 71 (.8) 5 (0.98) 40 (9.45) 155 (6.10) 10 (4.0) 178 (7.01) 8.5 (0.4) 190 (7.45) 170 (6.69) Transmitter wall mounted, dimensions in mm (inch) Transmitter compact mounted, dimensions in mm (inch) Siemens FI /69
9 Schematics Internal connection Top of connection Board Passive output Open drain Output A Output B Shield Positive logic External connection Connection Variant V 0 V Negative logic V 0 V I < 50 ma R I < 50 ma V 5 V DC Signal R V 5 V DC Signal Electrical connection of SITRANS FUS080 Analog module SITRANS FUS080 /70 Siemens FI
SITRANS F flowmeters SITRANS F US. Transmitter FUS080. 4/194 Siemens FI
Overview The transmitter is available in an IP67/NEMA X/6 enclosure and is designed for use in the flowmeters series: SONOKIT (1- or 2-track) FUS380 (2-track) FUE380 (2-track) The transmitter FUS080 is
More informationSITRANS F flowmeters SITRANS F US. Transmitter FUS060. Overview
Overview Function Displays and keypad Operation of the SITRANS FUS060 transmitter can be carried out using: Keypad and display unit HART communicator PC/laptop and SIMATIC PDM software via HART communication
More informationFlow Measurement SITRANS F US Inline
Flowmeter SITRANS FUE80 with CT approval Overview The 2-path flowmeter SITRANS FUE80 comes as battery or mains-powered and is designed to measure water flow in district heating plants, local networks,
More informationFlow Measurement SITRANS F US Inline
Flowmeter SITRANS FUS80 standard Overview Design The -path design of SITRANS FUS80 ensures maximum accuracy under short inlet conditions. The flowmeter consists of a flow sensor pipe, 4 transducers/transducer
More informationFlow Measurement. SITRANS F US Inline. Flowmeter SITRANS FUS380 standard. 4/254 Siemens FI Overview
Flowmeter SITRANS FUS380 standard Overview Design The 2-track design of SITRANS FUS380 ensures maximum accuracy under short inlet conditions. The flowmeter consists of a flow sensor pipe, transducers/transducer
More informationSITRANS F flowmeters SITRANS F US. Flowmeter FUE380 with approval. 4/230 Siemens FI Overview
SITRANS F flowmeters Siemens AG 009 Overview The -track flowmeter SITRANS FUE380 comes as battery or mains-powered and is designed to measure water flow in district heating plants, local networks, boiler
More informationSITRANS F flowmeters SITRANS F US. SONOFLO SONO 3000 transmitter. 4/152 Siemens FI Overview
Overview Design The transmitter is available in different enclosure to fit any demands: IP67 enclosure for compact or wall mounting IP00 as a 19 insert IP65 for wall mounting IP65 enclosure in stainless
More informationSITRANS F flowmeters SITRANS F US SONOCAL /184 Siemens FI
Overview Integration The flowmeter pulse output is often used as input for heat calculators. The range of meters enables optimum measurement of energy consumption. The analog output is used to inform the
More informationSITRANS F flowmeters SITRANS F M. Transmitter Transmag 2 with sensor 911/E 4/77. Overview
Overview Design The complete flowmeter consists of a flow sensor and an associated transmitter from the Transmag 2 for pulsed alternating field. These are available as remote and compact versions ( 911/E
More informationFLOWMETER. Siemens MAG 5000/6000. Overview
Overview Design The transmitter is designed as either IP67 NEMA 4X enclosure for compact or wall mounting or 19" version as a 19 insert as a base to be used in: 19" rack systems Panel mounting IP65/NEMA
More informationFlow Measurement SITRANS F M
Overview Mode of operation The flow measuring principle is based on Faraday s law of electromagnetic induction according to which the sensor converts the flow into an electrical voltage proportional to
More informationFlow Measurement SITRANS F M. Flow sensor MAG /49. Overview
Siemens AG 2010 Flow Measurement Overview Mode of operation The flow measuring principle is based on Faraday s law of electromagnetic induction according to which the sensor converts the flow into an electrical
More informationFlow Measurement SITRANS F M
Overview Mode of operation The flow measuring principle is based on Faraday s law of electromagnetic induction according to which the sensor converts the flow into an electrical voltage proportional to
More informationSITRANS F flowmeters SITRANS F M. Flow sensor MAG /48 Siemens FI Overview
Siemens AG 2009 Overview Integration The complete flowmeter consists of a flow sensor and an associated transmitter MAG 5000, 6000 or 6000 I. The flexible communication concept USM II simplifies integration
More informationFlow Measurement SITRANS F M. Transmitter TRANSMAG 2 with sensor 911/E 4/101. Overview
Siemens AG 2010 Flow Measurement Overview Design The complete flowmeter consists of a flow sensor and an associated transmitter from the TRANSMAG 2 for pulsed alternating field. These are available as
More informationLevel Measurement. Continuous level measurement Radar transmitters SITRANS LR460. 4/258 Siemens FI
Overview The is a -wire, 2 GHz FMCW radar level transmitter with extremely high signal-to-noise ratio and advanced signal processing for continuous monitoring of solids up to 100 m (328 ft). It is ideal
More informationClamp-on ultrasonic flowmeters have six product families: max. 2% solids
System info and selection guide Ultrasonic flowmeters Overview Siemens offers two types of ultrasonic flowmeters, wetted flowmeters and clamp-on flowmeters. This offers the end user the maximum flexibility
More informationLevel Measurement Continuous level measurement Radar transmitters
Overview Benefits Process Intelligence for advanced signal processing and quick and easy adjustment Self-guided quick start wizard for plug and play startup 2 GHz provides superior reflective properties
More informationModel Sono-Trak Transit Time
Model Sono-Trak Transit Time Ultrasonic Flow Meter Engineered for performance excellence, the Sono-Trak Transit Time ultrasonic meter combines non-invasive, bi-directional measurement with advanced ultrasonic
More informationDigital flowmeter for continuous flow measurement
8025 Flowmeter INSERTION Digital flowmeter for continuous flow measurement Compact or remote version for DN06 to DN400, PN10 Displays both flow rate and volume (with two totalizers) On site calibration
More informationDigital flowmeter for continuous flow measurement
8025 Flowmeter INSERTION Digital flowmeter for continuous flow measurement Compact or remote version for DN06 to DN400, PN10 Displays both flow rate and volume (with two totalizers) On site calibration
More informationSITRANS F US SONOCAL series 3000
s Handbook series 3000 Ultrasonic heat meter and flowmeter The ultrasonic heat meter series 3000 is an ideal combination of a SITRANS F US SONOFLO ultrasonic flowmeter, a energy calculator type SITRANS
More informationDigital flow transmitter for continuous flow measurement
Digital flow transmitter for continuous flow measurement Compact or remote version for DN 06 to 400, PN10 Shows both flow rate and volume (with two totalizers) Automatic-calibration: TEACH-IN Simulation:
More informationSonoMeter 31 Energy Meters
SonoMeter 31 Energy Meters Description MID examination certificate no.: LT-1621-MI004-023 The Danfoss SonoMeter 31 is a range of ultrasonic, compact energy meters intended for measuring energy consumption
More informationElectromagnetic Flow Transmitter
Electromagnetic Flow Transmitter Sensor in solid state technology Working as a transmitter and/or as an On/Off controller Automatic-calibration of full scale: Teach-In Clean in place (CIP) Type can be
More informationSITRANS F M. Battery-operated water meter MAG /113. application
Overview Application The following MAG 8000 versions are available as stand-alone water meters: MAG 8000 (7ME6810) for abstraction and distribution network MAG 8000 CT (7ME6820) for revenue and bulk metering
More informationUFM 800 W, C Ultrasonic flowmeter for water and wastewater
KROHNE 08/2000 7.02343.21.00 GR/PRINTO, C Ultrasonic flowmeter for water and wastewater...with weld-in sensors for metal pipelines...withbuilt-on or built-in sensors for open channels Variable area flowmeters
More informationElectromagnetic flowmeters Transmitter types MAG 5000, MAG 6000
s Operating Manual Edition 05/2006 - Revision 05 SITRANS F M MAGFLO Electromagnetic flowmeters Transmitter types MAG 5000, MAG 6000 [ ] Technical Documentation (handbooks, instructions, manuals etc.) on
More informationUltrasonic level transmitter, non-contact
Ultrasonic level transmitter, non-contact Type 8175 can be combined with... Compact, remote versions for level measurement up to 10 m Multi language menu control Interference echo filter Automatic calibration:
More informationJUMO Wtrans E01. Measuring probe for humidity, temperature, and CO 2 with wireless data transmission. Brief description. Universal Wtrans receiver
Page 1/13 JUMO Wtrans E01 Measuring probe for humidity, temperature, and CO 2 with wireless data transmission Humidity from 0 to 100 % RH (incl. -40 to +80 C) or CO 2 from 0 to 2000/5000/10000 ppm or Temperature
More informationFlow Measurement SITRANS F M
Battery-operated water meter MAG 8000 Overview Application The following MAG 8000 versions are available as stand-alone water meters: MAG 8000 (7ME6810) for abstraction and distribution network MAG 8000
More informationSITRANS F US SONOCAL series 3000
s Handbook SITRANS F US SONOCAL series 3000 Ultrasonic heat meter and flowmeter District heating applications Chilled water applications Combined cooling/heating application [ ] Order no.: FDK:521H1087
More informationTechnical specification FLUXUS F401 H2O
Technical specification Ultrasonic flowmeter for water Portable, very robust and easy-to-use ultrasonic flowmeter for the water and wastewater industry Features Very high bi-directional measuring accuracy
More informationE l e c t r o m a g n e t i c f l o w m e t e r s
E l e c t r o m a g n e t i c f l o w m e t e r s P r o v e n A N D R e l i a b l e F l o w M e a s u r e m e n t 2 MJK MagFlux flow meters combine high accuracy, stability and low maintenance. Without
More informationType PLC Fitting. Valve for Continuous control. Diaphragm valve. Output
Digital Inductive conductivity transmitter Optimal solution for conductivity measurements in difficult fluids (polluted, dirty,...) PEEK/PPA version for CIP applications Large range of process connections
More informationSonoSelect 10 and SonoSafe 10 Energy Meters
SonoSelect 10 and SonoSafe 10 Energy Meters Description The Danfoss SonoSelect 10 and SonoSafe 10 are ultrasonic compact energy meters intended for measuring energy consumption in heating and cooling applications
More informationDigital batch controller
INSERTION Digital batch controller Type 8025 can be combined with... Compact or remote version for DN06 to DN400, PN10 Dosing On site calibration by Teach-In Check of input/output signals Total and daily
More informationFlow Switch - 2 programmable thresholds. Stand Alone (Battery) - Battery powered, - 2 totalizers display, - Local flow display,
DN 15 - DN 50; PN Advantages / Benefits Easy System integration by Easy LINK provides low cost of ownership Easy commissioning due to multi-language, menu-guided operation TEACH-IN: automatic calibration
More informationFlow Measurement SITRANS F US Clamp-on
Overview SITS FUH1010 clamp-on non-intrusive ultrasonic flowmeter is ideal for applications carrying crude oil, refined petroleum or liquefied gas. SITS FUH1010 has three application areas: Interface detectors,
More informationMagFlux ELECTROMAGNETIC FLOWMETERS BROCHURE EN 3.05 MAGFLUX BROCHURE 1401
MagFlux ELECTROMAGNETIC FLOWMETERS BROCHURE EN 3.05 MAGFLUX BROCHURE 1401 P R O V E N A N D R E L I A B L E F L O W M E A S U R E M E N T 2 MJK MagFlux flow meters combine high accuracy, stability and
More informationAdvanced instrumentation solutions crafted with highest precision
www.adeptfluidyne.com Advanced instrumentation solutions crafted with highest precision Working Principle The Transit Time Flowmeter utilises two transducers that function as both ultrasonic transmitters
More informationSONOMETER TM 1100 Ultrasonic compact energy meter
Data sheet SONOMETER TM 1100 Ultrasonic compact energy meter Description/Application MID examination certificate no. : DE-10-MI004-PTB003 The SONOMETER 1100 is an ultrasonic static compact energy meter
More informationDigital inductive conductivity transmitter
Digital inductive conductivity transmitter Optimal solution for conductivity measurements in difficult fluids (polluted, dirty,...) PEEK/PPA version for CIP applications Large range of process connections
More informationLevel Measurement Continuous level measurement Radar transmitters
Overview Configuration Mounting on a nozzle is a 2-wire 25 GHz pulse radar level transmitter for continuous monitoring of solids and liquids in storage vessels including extreme levels of dust and high
More informationFlow Measurement SITRANS F M
Battery-operated water meter MAG 8000 Overview Application The following MAG 8000 versions are available as stand-alone water meters: MAG 8000 (7ME6810) for abstraction and distribution network MAG 8000
More informationInfocal 9 Energy calculator
Infocal 9 Energy calculator Description/Application MID examination certificate no.: LT-1621-MI004-028 The INFOCAL 9 is an energy calculator, e.g. for combination with or SonoSensor 30. It is especially
More informationSITRANS T measuring instruments for temperature
Overview Our field devices for heavy industrial use HART, Universal 4 to 20 ma, universal Field indicator for 4 to 20 ma signals The temperature transmitter SITRANS TF works where others feel uncomfortable.
More informationIFC 010 Signal Converter
KROHNE 04/2003 7.02347.22.00 GR Signal Converter for electromagnetic flowmeters Easy to install Low-cost signal converter, measuring error < 0.5% of the measured value Easy user-friendly operation Self-monitoring
More informationTechnical specification FLUXUS WD
Technical specification FLUXUS WD Non-invasive ultrasonic flow measurement on buried pipes Permanently installed clamp-on ultrasonic flow measurement system for buried water and wastewater pipes Features
More informationSITRANS F flowmeters. SITRANS F M System information MAGFLO electromagnetic flowmeters 4/11
Overview family are designed for measuring the flow of electrically conductive mediums. Benefits System information FLO Easier to commission for 5000, 6000, 6000 I All FLO pulsed DC feature a unique SENSORPROM
More information4/11. Overview. Easier service Transmitter replacement requires no programming. SENSORPROM automatically updates all settings after initialization.
Overview family are designed for measuring the flow of electrically conductive mediums. Benefits Easier commissioning of 5000, 6000, 6000 I All pulsed DC feature a unique SENSORPROM memory unit which stores
More informationLevel Measurement. Continuous level measurement - Radar transmitters SITRANS LR400 5/229. Overview
Overview Application It provides excellent results on low dielectric media. is available for standard applications and for applications that require explosion proof protection. features robust enclosure,
More informationKMS305W. ManuFlo Page 1 MANU ELECTRONICS PTY LTD Flow Measurement Products. Electromagnetic Wafer Flowmeters with S300 display
Electromagnetic Wafer Flowmeters with S300 display for corrosive chemicals/acids & slurries (sizes: 2.5mm to 100mm) 0BFEATURES: For aggressive chemicals, slurries, oxides, grouts & dosing applications
More informationLevel Measurement. Continuous level measurement - Radar transmitters SITRANS LR400 5/229. Overview
Overview Application It provides excellent results on low dielectric media. is available for standard applications and for applications that require explosion proof protection. features robust enclosure,
More informationUTM10 Series Ultrasonic Transit-time Flowmeters
Ultrasonic Transit-time meters Description UTM10 ultrasonic flow and energy meters clamp onto the outside of pipes and do not make contact with the internal liquid. The technology has inherent advantages
More informationSONOMETER TM 1100 Ultrasonic compact energy meter
Data sheet SONOMETER TM 1100 Ultrasonic compact energy meter Description/Application MID examination certificate no. : DE-10-MI004-PTB003 The SONOMETER 1100 is an ultrasonic static compact energy meter
More informationSITRANS F flowmeters. SITRANS F R Rotary-piston meters Accessory modules 4/431. Overview. Siemens AG 2009
Siemens AG 2009 SITRANS F flowmeters Rotary-piston meters Accessory modules Accessory modules For quantity measurements in conjunction with electromechanical and electronic pulse counters As transmitter
More informationRHE12. Hazardous Area Coriolis Mass Flow Transmitter. Features. Applications. Benefits
RHE12 Hazardous Area Coriolis Mass Flow Transmitter Features Field mounting Compact, pressure safe housing ATEX and CSA approvals for installation in hazardous areas 24 VDC power supply Configurable analog
More informationBrunata Optuna H Ultrasonic energy meter Type 775 Installation Guide Edition 1.2
Ultrasonic energy meter Type 775 Installation Guide Edition 1.2 UK-QB101575 / 29.05.2012 Brunata a/s is a Danish owned company. We have more than 90 years of experience within developing and producing
More informationElectromagnetic flowmeters and switches DWM 1000/2000
KROHNE 10/2000 D 20 DW10 02 E GR Electromagnetic flowmeters and switches DWM 1000/2000 Variable area flowmeters Vortex flowmeters Flow controllers Electromagnetic flowmeters Ultrasonic flowmeters Mass
More informationElectro-Magnetic Flowmeters COPA-XE
Data Sheet Electro-Magnetic Flowmeters COPA-XE 10DX4311 Flowmeter system utilizes a smart microprocessor converter System accuracy of ± 0.5% of rate Field configurable via integral pushbuttons, eliminates
More informationJUMO Wtrans Receiver with Wireless Data Transmission
Data Sheet 902931 Page 1/10 JUMO Wtrans Receiver with Wireless Data Transmission k For measuring temperature, pressure, potentiometer, and voltage. k Interface RS485 with Modbus protocol k Wireless measured
More informationph or ORP Transmitter
ph or ORP Transmitter Programmable outputs: two transistor and single or dual analog 4-20 ma (Process + Temp) Removable backlighted display Universal process connection Compatible with 120 mm ph/ ORP probes
More informationB850 Boiler House Energy Monitor
Local regulations may restrict the use of this product to below the conditions quoted. In the interests of development and improvement of the product, we reserve the right to change the specification without
More informationSITRANS F C. Flowmeter SITRANS FC430 3/151. Technical specifications. Overview
Flow Measurement Flowmeter SITRANS FC40 Overview The complete flowmeter system SITRANS FC40 can be ordered for standard, hygienic or NAMUR service. All versions can be ordered for CT service, according
More informationUltrasonic level meters ULM 70
průmyslová elektronika Ultrasonic level meters ULM 70 For continuous level measurement of liquids (even if polluted), mash and paste materials in open or closed vessels, sumps, open channels, drains, etc.
More informationEN-2018 MAGNETIC FLOW METERS
EN-2018 MAGNETIC FLOW METERS www.meatest.com 1 MEASURING PRINCIPLE Having no moving or mechanical parts in the flow profile electromagnetic flow meters cause no pressure drop, are virtually maintenance
More informationVersaFlow Ultrasonic clamp-on Flowmeter Technical Datasheet. Specification. Applications. Highlights. Industries. 34-VF September 2009
VersaFlow Ultrasonic clamp-on Flowmeter Technical Datasheet 34-VF-03-14 September 2009 Specification Clamp-on technology HONEYWELL S VERSAFLOW stands for continuity and long term reliability. Flow measurement
More informationJUMO Wtrans Receiver Universal Receiver for JUMO Wireless Measuring Probes
Data sheet 902931 Page 1/10 JUMO Wtrans Receiver Universal Receiver for JUMO Wireless Measuring Probes For processing physical measurands of the JUMO Wtrans series RS485 interface with Modbus protocol
More informationFLOMID FX Electromagnetic Flowmeter
FLOMID FX Electromagnetic Flowmeter Working pressure manufacturing according to PED 97/23/CE (Lloyd s Register Certificate Nº 031) Introduction Modular design in two versions: Compact, sensor and electronics
More information( F L O W I Z F A M I L Y )
THE MOST ACCURATE BATTERY POWERED SYSTEM ( F L O W I Z F A M I L Y ) E l e c t r o m a g n e t i c c o n v e r t e r p o w e r e d b y b a t t e r i e s, s o l a r p a n e l o r D C p o w e r w i t h 4
More informationmass flowmeter for compressed air
mass flowmeter for compressed air VARIOMASS MF High End electronic for air measurement & analyse - 1 - The VARIOMASS flow meter for compressed air is a comfortable system for air mass flow measurement,
More informationKATflow 230 Portable Clamp-On Ultrasonic Flowmeter
Portable flowmeter with two measurement channels, optional process outputs and Heat Quantity Measurement capability For commonly used pipe materials and diameters from 10 mm to over 3.0 m Intuitive menu,
More informationMJK Expert 700 / 800 / 900 / 1100 / 2100 MJK Expert 1400 / 3400
Data Sheet MJK Expert 700 / 800 / 900 / 1100 / 2100 MJK Expert 1400 / 3400 Submersible Hydrostatic s Rugged and versatile We reserve the right to continuously improve our products and make any change in
More informationMHPS MHPS. Modular pressure transmitter. Technical documentation. Table of content. Characteristics - applications - technical data
Technical documentation Table of content Page 2: Page 3: Page 4: Page 5: Page 6: Page 7: Page 8: Characteristics - applications - technical data Technical data - input quantity - output quantity Electrical
More informationLST400 Ultrasonic level / open channel flow transmitter
Data sheet DS/LST400 EN Rev.C LST400 Ultrasonic level / open channel flow transmitter Measurement made easy Reduced installation cost Easy access terminations Integrated echo display makes for easy troubleshooting
More informationINLINE flowmeter for continuous flow measurement
INLINE flowmeter for continuous flow measurement Economic integration in pipe systems without any additional piping 3-wire frequency pulse version to directly interface with PLC s (both PNP and NPN) Connection
More informationFlow Measurement SITRANS F M
Battery-operated water meter MAG 8000 Overview Application The following MAG 8000 versions are available as stand-alone water meters: MAG 8000 (7ME6810) for abstraction and distribution network MAG 8000
More informationSignet 9950 Dual Channel Transmitter
Signet 9950 Dual Channel Transmitter Member of the SmartPro Family of Instruments Features One instrument for multiple sensor types Multiple language support for (Gen 2a) or later in Simplified Chinese,
More informationDigital conductivity transmitter
Digital conductivity transmitter Compact version with integrated conductivity electrodes Remote version with seperated transmitter for short (15 ft.) or long (1500 ft.) distance Commissioning is easy due
More informationSITRANS F M MAGFLO Electromagnetic Flowmeters Explore the Siemens Solution. sitrans f
SITRANS F M MAGFLO Electromagnetic Flowmeters Explore the Siemens Solution sitrans f s Water and Wastewater MAGFLO for water processes Cost effective solution The MAG 5000 transmitter and MAG 5100 W sensor
More informationMODEL AT-10 ANALOG TRANSMITTER
MODEL AT-10 ANALOG TRANSMITTER INSTALLATION & OPERATING MANUAL Industrial Weighing Systems 9 Richmond Street Picton, Ontario K0K 2T0 Phone: 613-921-0397 Fax: 613-476-5293 Web: www.iwsystems.ca info@iwsystems.ca
More informationMagnetic-inductive flow meter. PITe / UMF2. Technical Datasheet. Maintenance-free Nearly no pressure drop Robust design Easy installation and start-up
Magnetic-inductive flow meter Technical Datasheet PITe / UMF2 Maintenance-free Nearly no pressure drop Robust design Easy installation and start-up Subject to change without notice 1 Function An electrically
More informationINSERTION paddle wheel flowmeter for continuous flow measurement
INSERTION paddle wheel flowmeter for continuous flow measurement Economic integration in pipe systems without any additional piping 3-wire frequency pulse version to directly interface with PLC s (both
More informationLevel Transmitter / Controller / Indicator. 3-in-1 package that is simple to install and use. With expanded ranges and improved chemical resistance.
Level Transmitter / Controller / Indicator 3-in-1 package that is simple to install and use. With expanded ranges and improved chemical resistance. 2.1 NEW Class 1, Division 1 Hazardous Areas Approved
More informationprosonic T FMU230, FMU231
Technical Information prosonic T FMU230, FMU231 Ultrasonic Level Measurement Compact transmitters for non-contact level measurement of fluids and coarse bulk materials Application The compact transmitters
More informationElectromagnetic Flowmeter Hygienic/Sanitary
MagMaster Electromagnetic Flowmeter Hygienic/Sanitary Specification DataFile Unrivalled, fully traceable flow performance, ±0.2% accuracy. Operable flow range: 000 : ensures precise revenue measurement;
More informationOPTISONIC Ultrasonic flowmeter for liquids in all industrial applications
OPTISONIC 3400 Ultrasonic flowmeter for liquids in all industrial applications Measurement of conductive and non-conductive, low and high viscous liquids, from -200 to +250 C / -328 to +482 F medium temperature
More informationOpen Channel Flowmeter 713
Open Channel Flowmeter 713 General Flow Converter 713 is designed for measuring and recording water flow in open ducts and channels. Flow Converter 713 is a complete instrument for the measuring of instantaneous
More informationABB MEASUREMENT & ANALYTICS DATA SHEET. Ultrasonic level LST400 Open channel flow transmitter
ABB MEASUREMENT & ANALYTICS DATA SHEET Ultrasonic level LST400 Open channel flow transmitter 2 ULTRASONIC LEVEL LST400 / OPEN CHANNEL FLOW TRANSMITTER DS/LST400 EN REV. D Measurement made easy Reduced
More informationWATERFLUX 3070 Technical Datasheet
WATERFLUX 3070 Technical Datasheet Engineered and manufactured for the water and wastewater industry Highly accurate measurement with extremely short in- and outlet lengths Battery operated, stand alone
More informationWESAN WP E ELECTRONIC METER WOLTMAN
APPLICATION Fully electronic bulk water meter for measuring the flow (cold water up to 30 C) in supply lines with high flow at low pressure loss. Highly accurate recording of all billing data. FEATURES
More informationRHE11. Hazardous Area Multifunction Coriolis Flow Transmitter. Features. Applications. Benefits
RHE11 Hazardous Area Multifunction Coriolis Flow Transmitter Features Wall or Pipe Bracket Mount Built in safety barriers allow operation with RHM sensor in hazardous area Selectable Metric and English
More informationINFOCAL 8 Energy calculator
Data sheet INFOCAL 8 Energy calculator Description/Application MID examination certificate no.: DE-10-MI004-PTB008 The INFOCAL 8 is an energy calculator e.g. for combination with SONO 1500 CT especially
More informationB850 Boiler House Energy Monitor
Local regulations may restrict the use of this product to below the conditions quoted. In the interests of development and improvement of the product, we reserve the right to change the specification without
More informationSHARKY 775 ULTRASONIC COMPACT METER. 4 Approved according EN 1434 and MID in class 2 with dynamic range of 1:250 (qi:qp) in class 2
APPLICATION ultrasonic compact energy meter can be used for measuring the energy consumption in heating / cooling application for billing purposes. The measurement principle is static and based on the
More informationTMU. Coriolis Mass Flow Meter. for liquids and gas
Coriolis Mass Flow Meter for liquids and gas measuring monitoring analysing TMU S5 OO Measuring range: 0-60 kg/h 0-2200 t/h water OO Accuracy: ± 0.1% of reading ±zero point stability (from liquids up to
More informationINLINE flowmeter for continuous flow measurement
INLINE flowmeter for continuous flow measurement Economic integration in pipe systems without any additional piping 3-wire frequency pulse version to directly interface with PLC s (both PNP and NPN) Connection
More informationIFC 050 Technical Datasheet
IFC 050 Technical Datasheet Signal converter for electromagnetic flowmeters For water and wastewater applications Multiple outputs, incl. active pulse output and RS485 Modbus Excellent price/performance
More informationTechnical Specification FLUXUS ADM 8127B
FLUXUS ADM 8127B Liquid Ultrasonic Flowmeter for Permanent Installation in Hazardous Areas in the Mining Environment FLUXUS ADM 8127B is especially designed for the stationary use in explosive atmosphere
More information