1 Data sheet SONOMETER TM 1100 Ultrasonic compact energy meter Description/Application MID examination certificate no. : DE-10-MI004-PTB003 The SONOMETER 1100 is an ultrasonic static compact energy meter especially designed for heating, cooling or combined heating/cooling application in local and district energy systems. The SONOMETER 1100 as a compact energy meter consists of the following components: - Ultrasonic flow sensor - Calculator with integral hardware and software for measuring flow rate, temperature and energy consumption - Pair of temperature sensors Features - 1st. approval in Europe for ultrasonic energy meter with dynamic range of q i /q p 1 : 250 in class 2 (q p 1.5 / 2.5 / 6 / 10 / 15 / 25 / 40 / 60 m³/h) - Complete dynamic range: 1 : Lithium battery, 230 V AC or 24 V AC mains unit - Battery lifetime 11 years (16 years optional) - Unique free- beam principle - Improved service-friendly energy meter design - Housings with thread and flange (PN 16 / 25) - Can be configured for heating, cooling or combined heating/cooling application - Temperature range: / 150 C - Overload temperature up to 150 C (q p = m 3 /h) - Swirl-free flow around reflector - Lower pressure loss - Robust stainless steel reflector - Insensitive to dirt - Available in nominal sizes q p 0.6 / 1.5 / 2.5 / 3.5 / 6 / 10 / 15 / 25 / 40 / 60 m³/h - Approved according to MID in class 2 and 3, and PTB K 7.2 for cooling - No calming sections necessary in the inlet and/or outlet (standard installation) Special Features - Power save mode - NOWA test capability - Remote reading via M-Bus, L-Bus, RS 232, RS 485, Radio or optical interface - Integrated Radio 868 MHz, Open Metering Standard (OMS) - Individual remote reading (Automatic Meter Reading) with add on modules Plug&Play - 2 communication ports (e.g. M-Bus + pulse input) - Improved radio performance - Individual tariff functions - History memory for 24 months - Extensive diagnostic displays - Dedicated district energy application telegram - Suitable for Danfoss ECL Comfort controller and ECL 310 internet portal connection - IZAR@SET parameterization software on Windows basis guarantees optimum adaptation to the user s specific needs DEN-SMT/PL VD.SH.J8.02 Danfoss 01/15 1

2 Description/Application, continued The SONOMETER 1100 is able to handle 3 types of applications (energy meter in outlet): Heat meter T H T C District heating/boiler application Heat meter with cooling tariff Combined heating/cooling application Cooling meter T C T H Chilled water application 2 VD.SH.J8.02 Danfoss 01/15 DEN-SMT/PL

3 Ordering: The standard codes are used for ordering. Heat meters standard codes 1): Code no. Flow sensor Nominal pressure Cable length 2) Module Energy unit Cable length 3) 087G1040 qp 0.6 m³/h / 110mm thread / 15 / G¾B PN16 1.5m M-Bus kwh (without digit after comma) 1.9m 087G1041 qp 1.5 m³/h / 110mm thread / 15 / G¾B PN16 1.5m M-Bus kwh (without digit after comma) 1.9m 087G1042 qp 1.5 m³/h / 130mm thread / / G1B PN16 1.5m M-Bus kwh (without digit after comma) 1.9m 087G1043 qp 2.5 m³/h / 130mm thread / / G1B PN16 1.5m M-Bus kwh (without digit after comma) 1.9m 187F11 qp 3.5 m³/h / 260mm thread / 25 / G1¼B PN16 1.5m kwh (without digit after comma) 1.9m 187F1121 qp 6 m³/h / 260mm thread / 25 / G1¼B PN16 1.5m kwh (without digit after comma) 1.9m 187F1122 qp 6 m³/h / 260mm flange 32 PN25 1.5m kwh (without digit after comma) 1.9m 187F1123 qp 10 m³/h / 300mm thread / 40 / G2B PN16 1.5m MWh (with 3 digit after comma) 1.9m 187F1124 qp 10 m³/h / 300mm flange 40 PN25 1.5m MWh (with 3 digit after comma) 1.9m 187F1125 qp 15 m³/h / 270mm flange 50 PN25 3m MWh (with 3 digit after comma) 2.9m 187F1126 qp 25 m³/h / 300mm flange 65 PN25 3m MWh (with 3 digit after comma) 2.9m 187F1127 qp 40 m³/h / 300mm flange 80 PN25 3m MWh (with 2 digit after comma) 2.9m 187F1128 qp 60 m³/h / 360mm flange 100 PN25 3m MWh (with 2 digit after comma) 2.9m 0 87G1118 qp 0.6 m³/h / 110mm thread / 15 / G¾B PN16 1.5m Radio OMS kwh (without digit after comma) 1.9m 087G1224 qp 1.5 m³/h / 110mm thread / 15 / G¾B PN16 1.5m Radio OMS kwh (without digit after comma) 1.9m 0 87G11 qp 1.5 m³/h / 130mm thread / / G1B PN16 1.5m Radio OMS kwh (without digit after comma) 1.9m 0 87G1121 qp 2.5 m³/h / 130mm thread / / G1B PN16 1.5m Radio OMS kwh (without digit after comma) 1.9m 187F1129 qp 3.5 m³/h / 260mm thread / 25 / G1¼B PN16 1.5m Radio OMS kwh (without digit after comma) 1.9m 187F1130 qp 6 m³/h / 260mm thread / 25 / G1¼B PN16 1.5m Radio OMS kwh (without digit after comma) 1.9m 187F1131 qp 6 m³/h / 260mm flange 32 PN25 1.5m Radio OMS kwh (without digit after comma) 1.9m 187F1132 qp 10 m³/h / 300mm thread / 40 / G2B PN16 1.5m Radio OMS MWh (with 3 digit after comma) 1.9m 187F1133 qp 10 m³/h / 300mm flange 40 PN25 1.5m Radio OMS MWh (with 3 digit after comma) 1.9m 187F113 4 qp 15 m³/h / 270mm flange 50 PN25 3m Radio OMS MWh (with 3 digit after comma) 2.9m 187F1135 qp 25 m³/h / 300mm flange 65 PN25 3m Radio OMS MWh (with 3 digit after comma) 2.9m 187F1136 qp 40 m³/h / 300mm flange 80 PN25 3m Radio OMS MWh (with 2 digit after comma) 2.9m 187F1137 qp 60 m³/h / 360mm flange 100 PN25 3m Radio OMS MWh (with 2 digit after comma) 2.9m 1) Codes above are EN version heat meters with low temperature (return pipe) installation. Codes with radio have D-cell battery installed and codes without radio have A-cell battery installed. 2) Cable length between calculator and flow sensor. 3) Cable length of temperature sensor. More standard codes are available regarding heat meters, high temperature installation, power supply and modules. DEN-SMT/PL VD.SH.J8.02 Danfoss 01/15 3

4 Ordering continued: Heat / cooling meters standard codes 1): Code no. Flow sensor Nominal pressure Cable length 2) Module Energy unit Cable length 3) 087G16 qp 0.6 m³/h / 110mm thread / 15 / G¾B PN16 1.5m M-Bus kwh (without digit after comma) 1.9m 087G17 qp 1.5 m³/h / 110mm thread / 15 / G¾B PN16 1.5m M-Bus kwh (without digit after comma) 1.9m 087G1068 qp 1.5 m³/h / 130mm thread / / G1B PN16 1.5m M-Bus kwh (without digit after comma) 1.9m 087G18 qp 2.5 m³/h / 130mm thread / / G1B PN16 1.5m M-Bus kwh (without digit after comma) 1.9m 187F1140 qp 3.5 m³/h / 260mm thread / 25 / G1¼B PN16 1.5m kwh (without digit after comma) 1.9m 187F1141 qp 6 m³/h / 260mm thread / 25 / G1¼B PN16 1.5m kwh (without digit after comma) 1.9m 187F1142 qp 6 m³/h / 260mm flange 32 PN25 1.5m kwh (without digit after comma) 1.9m 187F1143 qp 10 m³/h / 300mm thread / 40 / G2B PN16 1.5m MWh (with 3 digit after comma) 1.9m 187F1144 qp 10 m³/h / 300mm flange 40 PN25 1.5m MWh (with 3 digit after comma) 1.9m 187F1145 qp 15 m³/h / 270mm flange 50 PN25 3m MWh (with 3 digit after comma) 2.9m 187F1146 qp 25 m³/h / 300mm flange 65 PN25 3m MWh (with 3 digit after comma) 2.9m 187F1147 qp 40 m³/h / 300mm flange 80 PN25 3m MWh (with 2 digit after comma) 2.9m 187F1148 qp 60 m³/h / 360mm flange 100 PN25 3m MWh (with 2 digit after comma) 2.9m 0 87G114 4 qp 0.6 m³/h / 110mm thread / 15 / G¾B PN16 1.5m Radio (OMS) kwh (without digit after comma) 1.9m 0 87G1145 qp 1.5 m³/h / 110mm thread / 15 / G¾B PN16 1.5m Radio (OMS) kwh (without digit after comma) 1.9m 0 87G114 6 qp 1.5 m³/h / 130mm thread / / G1B PN16 1.5m Radio (OMS) kwh (without digit after comma) 1.9m 0 87G1147 qp 2.5 m³/h / 130mm thread / / G1B PN16 1.5m Radio (OMS) kwh (without digit after comma) 1.9m 187F1149 qp 3.5 m³/h / 260mm thread / 25 / G1¼B PN16 1.5m Radio (OMS) kwh (without digit after comma) 1.9m 187F1150 qp 6 m³/h / 260mm thread / 25 / G1¼B PN16 1.5m Radio (OMS) kwh (without digit after comma) 1.9m 187F1151 qp 6 m³/h / 260mm flange 32 PN25 1.5m Radio (OMS) kwh (without digit after comma) 1.9m 187F1152 qp 10 m³/h / 300mm thread / 40 / G2B PN16 1.5m Radio (OMS) MWh (with 3 digit after comma) 1.9m 187F1153 qp 10 m³/h / 300mm flange 40 PN25 1.5m Radio (OMS) MWh (with 3 digit after comma) 1.9m 187F115 4 qp 15 m³/h / 270mm flange 50 PN25 3m Radio (OMS) MWh (with 3 digit after comma) 2.9m 187F1155 qp 25 m³/h / 300mm flange 65 PN25 3m Radio (OMS) MWh (with 3 digit after comma) 2.9m 187F1156 qp 40 m³/h / 300mm flange 80 PN25 3m Radio (OMS) MWh (with 2 digit after comma) 2.9m 187F1157 qp 60 m³/h / 360mm flange 100 PN25 3m Radio (OMS) MWh (with 2 digit after comma) 2.9m 1) Codes above are EN version heat/cooling meters with low temperature (return pipe) installation. Codes with radio have D-cell battery installed and codes without radio have A-cell battery installed. 2) Cable length between calculator and flow sensor. 3) Cable length of temperature sensor. More standard codes are available regarding cooling and heat/cooling meters, high temperature installation, power supply and modules. 4 VD.SH.J8.02 Danfoss 01/15 DEN-SMT/PL

5 Accessories Type Designation Set Code No. M-Bus module 1 pc 087G6027 Communication M-Bus module 72 pcs 087G6028 RS232 module with cable 1 pc 087G6031 RS485 module 1 pc 087G6032 Pulse input module (2 inputs) 1 pc 087G6037 Pulse input module (2 inputs) 72 pcs 087G6038 Pulse output module (2 outputs) 1 pc 087G6039 Function Pulse output module (2 outputs) 72 pcs 087G6040 Combined module (2 pulse inputs / 1 pulse output) 1 pc 087G6041 Combined module (2 pulse inputs / 1 pulse output) 72 pcs 087G6042 Analogue output module (4 ma) 1 pc 087G6034 battery 3.6 V DC (A-cell) 1 pc 087G60 Supply voltage battery 3.6 V DC (D-cell) 1 pc 087G6022 mains unit 230 V AC 1 pc 087G6024 mains unit 24 V AC 1 pc 087G6025 Temperature sensors ø 5.2 mm type Pair Code No. Pt 500 / 3 m cable, MID 1 087G6046 Pt 500 / 5 m cable, MID 1 087G6047 Pt 500 / 10 m cable, MID 1 087G6048 Sensor pockets Ball valves For ø 5.2 mm type Pair Code No. brass / 35 mm 1 087G6053 brass / 52 mm 1 087G6054 brass / 85 mm 1 087G6055 brass / 1 mm 1 087G6056 stainless steel / 85 mm 1 087G6057 stainless steel / 1 mm 1 087G6058 stainless steel / 155 mm 1 087G6059 stainless steel / 210 mm 1 087G6060 Dimension (IG) Set Code No. 1 pc 187F0593 G ½ 12 pcs 087H0118 G ¾ G 1 1 pc 187F pcs 087H pc 187F pcs 087H01 Adapters for mounting temperature sensors Coupling thread Sensor thread Set Code No. R ½ M 10 x 1 1 pc 087G6075 R ½ M 10 x 1 32 pcs 087G6076 Tailpieces AGV AGZ Threaded Dimension (AGV x AGZ) Set Code No. R ½ x G ¾ B 1 pc 087G6071 R ¾ x G 1 B 1 pc 087G6072 R 1 x G 1¼ B 1 pc 087G6073 R 1½ x G 2 B 1 pc 087G6074 Software The IZAR@SET parameterization software on windows basis is a convenient tool for handling the energy meter. It is used for: - commissioning and meter configuration - reading out measured values - application analysis - print the meter protocol DEN-SMT/PL VD.SH.J8.02 Danfoss 01/15 5

6 Technical data q p Nominal [m 3 /h] q Maximum s [m Flow rate /h] Standard q ranges i minimum [l/h] Extended q i minimum3) [l/h] / 100 / 100 1) / /600 2) / Starting [l/h] Nominal [mm] Diameter Connection AGZ G ¾B G 1B FL G ¾B G 1B FL G 1B FL G 1¼B FL G 1¼B FL G 2B FL FL FL FL FL Tailpiece AGV R ½ R ¾ - R ½ R ¾ - R ¾ - R 1 - R 1 - R 1½ Operating PN Maximum pressure [bar] 16 / / / / / Flow heating sensor cooling [ C] Temp. heat. /cool range Volume measuring T Battery supply: 1 cycle [s] Mains unit supply: 1/8 Medium circulation water (ph-value: 7-10); if additives are used, it must meet AGFW FW510 specifications Pressure Δp At q loss p [mbar] / Overall length [mm] Temperature sensors Type Pt 500 ø 5.2 mm with 2-wire leads Sensor current [ma] Pt 500 peak < 2; rms < Measuring T A-cell battery: 16; D-cell battery: 4 cycle [s] Mains unit supply: 1 Input Max. temp. Δθ max difference [K] 177 Min. temp. Δθ min difference [K] 3 Supply voltage Basic features Display indication Starting temp. difference Abs. temp. measuring range Operating voltage Δθ [K] θ [ C] U N 3.6 V DC (Lithium-battery) / 230 V AC / 24 V AC Ambient class class E2 + M2 Protection class calculator: IP 54 flow sensor: IP 54 (heating) / IP 65 (heat / cooling, cooling) Ambient operating temperature C ( > 35 C max. 4 weeks) Ambient storage temperature C ( > 35 C max. 4 weeks) Max. ambient humidity 93% rel. humidity Type Static energy meter Measuring process Ultrasonic volume measurement Display LCD, 8-digit Units MWh - kwh - GJ - Gcal - MBtu - gal - GMP - C - F - m³ - m³/h Total values Values displayed Power - energy - flow rate - temperature - volume 1) Only for horizontal installation 2) Only in rising or falling pipes or tilted installation 3) Extended minmum flow rate for dynamic range of 1:250. Available on request Pressure loss graph Measuring accuracy Class 2 6 VD.SH.J8.02 Danfoss 01/15 DEN-SMT/PL

7 Design and function The SONOMETER 1100 as a compact energy meter consists of the following components: - Ultrasonic flow sensor; - Calculator with integral hardware and software for measuring flow rate, temperature and energy consumption; - Pair of temperature sensors. The calculator contains all the necessary circuits for recording the flow rate and temperature and for calculating, logging and displaying the data. The calculator housing can be mounted directly on the flow sensor or on the wall. The energy meter can be conveniently read from a single-line 8-digit display with units and symbols. A push-button provides user-friendly control of the various display loops. All failures and faults are recorded automatically and shown on the LC display. To protect the reading data, all the relevant data are saved in a non-volatile memory (EEPROM). This memory saves the measured values, device parameters and types of error at regular intervals. Ultrasonic flow sensor The ultrasonic technology of the flow sensor permits very high measuring accuracy and can be used in the supply or return line. The flow sensor meets the requirements of MID in class 2 and 3. The standard cable length between the calculator and the flow sensor is 1.5 m or 3 m (optional 5 m). Supply voltage: - Lithium battery 3.6 V DC A-cell (11 years typical lifetime) - Lithium battery 3.6 V DC D-cell (16 years typical lifetime) - Mains unit 230 V AC or 24 V AC with changeable backup battery Temperature Sensors Pairs of Pt 500 ø5.2 mm temperature sensors with 2-wire leads are used. Cable length 2 m, 3 m, 5 m or 10 m are available. Integrated Radio Integrated Radio is an interface for communication with radio receiver. - Frequency band: 868 MHz - Type of radio telegram: Open Metering Standard (OMS) - Transmission data updating: Online - no time delay between value measurement and data transmission - Data transmission: Unidirectional - Sending interval: s; depending on length of telegram (duty cycle) Interfaces - Optical: ZVEI interface as standard, for communication and testing, M-Bus protocol. - M-Bus: Configurable telegram, according to EN Data reading and parametrization are via two wires with polarity reversal protection. - L-Bus: Adapter for external radio module; configurable telegram, according to EN Data reading and parametrization are via two wires with polarity reversal protection. M-Bus protocol. - RS232: Serial interface for communication with external devices. M-Bus protocol. - RS485: Serial interface for communication with external devices. M-Bus protocol. - Pulse output: Module with 2 Open Collector pulse outputs (potential-free). Configurable via IZAR@SET software. Default pulse outputs are energy and volume. For battery powered energy meters in AMR (automatic meter reading) systems the fastest M-Bus reading interval is every 3 minutes! - Pulse input: Module with 2 pulse inputs, max. 8 Hz with minimum pulse duration of 10 msec, input resistance 2.2 M Ohms, terminal voltage 3V DC, cable length up to maximum 10m. The pulse value and the unit is configurable for energy, water, gas or electrical meter by IZAR@SET. Data can be transferred remotely. Also two accounting day s are available for both inputs. - Combined pulse input / output: Module with 2 pulse inputs and 1 pulse output. Configurable via IZAR@SET software. - Analogue output: Module for 4... ma with 2 programmable passive outputs, programmable value in case of error. Output values can be power, flow rate, temperatures. Configurable via IZAR@SET software. Only for mains powered energy meters! interface / slot 1 no modul M-Bus interface / slot 2 RS232 RS485 pulse input L-Bus (for external radio) no module M-Bus RS232 RS485 pulsse input pulse output pulse in-/ output analogue output 4...mA L-Bus (for external radio) combination is possible combination is not possible * integrated radio is always possible Event Memory Events such as changes and faults are stored in a nonvolatile memory with a capacity of up to 127 entries. The following events are recorded: - Checksum error - Temperature measurement error - Ultrasonic operating time measurement errors - Start and end of test mode - Changing of the main configuration Monthly Memory The SONOMETER 1100 has a history memory of 24 months. The following values are stored in the EEPROM on the programmable interval (daily, weekly, monthly): - Date/ Time - Cumulated energy - Tariff energy 1 - Tariff energy 2 - Tariff definition 1 - Tariff definition 2 - Cumulated volume - Error hour counter - Value of max. flow - Time max. flow - Date max. flow - Value of max. power - Time max. power - Date max. power - Pulse input counter 1 - Pulse input counter 2 - Pulse 1 definition - Pulse 2 definition - Operating days - Max. forward temperature - Time max. forward temperature - Date max. forward temperature - Max. return temperature - Time max. return temperature - Date max. return temperature DEN-SMT/PL VD.SH.J8.02 Danfoss 01/15 7

8 Design and function, continued Log Memory The large two log memory blocks are used to store consumption values. The storage frequency can be selected from various storage intervals (1, 2, 3, 4, 5, 6, 10, 12, 15,, 30, 60 minutes or the default setting of 24 hours, Day in the month, Day of the week, (1024 seconds), 15th or end of month). The data saved in the log memory can be used for the following analyses: - Reading the calculator on a certain day. Example: If the day for reading is 01.10, the calculator reading is displayed for the period from of the previous year to of the current year. - Comparison of the last consumption period with the preceding period Extract of possible log memory settings Memory block area 1 Storage interval Values Date block size example Number of data records Recording period 1 hour Error status, overload time temperature, 16 byte days 24 area 2 overload time flow rate, supply 16 byte days hours temperature, return temperature, date area 1 1 hour and time, energy, tariff energy 1, tariff 8 byte days energy 2, tariff definition 1, tariff definition 24 area 2 2, volume, error day counter hours 8 byte days Max. Actual Values Memories The calculator creates maximum values for power, flow rate and temperatures based on consumption time, which are stored in the EEPROM. The integration intervals are adjustable to 6, 15, 30 or 60 minutes, 24 hours (and 1024 seconds). Default setting is 60 minutes. Tariff Function The calculator offers four optional tariff memories for monitoring plant load states for limit tariffs. Extensive tariff conditions make it possible to adapt the energy meter individually to the required customer-specific applications. The following limit types are possible: (This example applies to the display with 3 decimal places) Type LIMIT LIMIT resolution T C 1 C T R T F C 1 C P kw 1 kw Q l / h 100 l / h Z 15 minutes Display Control The readings are displayed on the calculator by a 8-digit LCD with units and symbols. Loop Structure The SONOMETER 1100 display has six loops. Some display windows consist of two (to maximum seven) displays that are shown alternately at 4-second intervals. Some pictures in loops or a complete loop can be deactivated separately. For quick visual guidance, the loops in the display are numbered from 1 to 6. The main loop with the current data, e.g. for energy, volume and flow rate is programmed as default setting. According to above table the energy or the time (in hours) how long the tariff condition is fulfilled will be stored in the tariff memories. 8 VD.SH.J8.02 Danfoss 01/15 DEN-SMT/PL

9 Overview of Loops DEN-SMT/PL VD.SH.J8.02 Danfoss 01/15 9

10 Informative Displays (Standard) Loop Sequence Window 1 Window 2 Window Accumulated energy 1.2 Volume 1.3 Accumulated energy (cooling) (Sequence will be shown only in a heat meter with cooling tariff ) 1.4 Flow Power Main loop 1.6 Forward / - return temperature 1.7 Temperature difference 1.8 Operating days Error hours 1.9 Error status 1.10 Display test Loop Sequence Window 1 Window 2 Window Accounting date 1 Accounting date 1 energy Accd 1A 2.2 Accd 1 Future accounting date Accounting date 1 previous year Accounting date 1 Accd 1L 2 Accounting date loop previous year energy 2.4 Accounting date 2 Accounting date 2 energy Accd 2A 2.5 Accd 2 Future accounting date Accounting date 2 previous year Accounting date 2 previous year energy Accd 2L Accounting date 2 previous year Pulse input 2 Pulse input volume 2 Loop Sequence Window 1 Window 2 Window 3 3 Info loop 3.1 Current date Current time 3.2,SEC_Adr' Secondary address 3.3,Pri_ Adr 1' Primary address 1 3.4,Pri_Adr 2' Primary address Installation position 3.6,Port 1 No. of the mounted module at port 1 3.7,Port 2 No. of the mounted module at port Status integrated radio (Sequence will be shown only in meters with integrated radio) 3.9 software version Checksum Loop Sequence Window 1 Window 2 Window ,In1' Accumulated value pulse input 1,PPI' pulse value 1 Pulse input loop 4.2,In2' Accumulated value pulse input 2,PPI' pulse value 2 Loop Sequence Window 1 Window 2 Window 3 Window 4 Window 5 Window 6 5 Tariff loop Only in a heat meter with cooling tariff. Loop Sequence Window 1 Window 2 Window 3 Window 4 Window 5 Window 6 6.1,LOG date last month energy volume max. flow rate max. power 6 6.2,LOG date month - 1 energy volume max. flow rate max. power Monthly value 6.3,LOG date month - 2 energy volume max. flow rate max. power loop ,LOG date month - 23 energy volume max. flow rate max. power Simple operation A push-button mounted on the front of the calculator is used to switch to the various displays. The button can be pressed for a short or long time. A short press of the button (< 3 seconds) switches to the next display within a loop and a long press (> 3 seconds) switches to the next display loop. The Energy window (sequence 1.1) in the main loop is the basic display. The calculator switches automatically to power save mode if the button is not pressed for approx. 4 minutes and returns to the basic display when the button is pressed again. The loop settings can be programmed to suit the customer s individual requirements using the IZAR@SET software. 10 VD.SH.J8.02 Danfoss 01/15 DEN-SMT/PL

11 Mounting Depending on the design, the energy meter is installed either in the low temperature or high temperature line as indicated on the type plate. The energy meter is to be installed so that the direction of flow corresponds to the direction of the arrow on the flow sensor. Ensure that the flow sensor is always filled with liquid on completion of installation. Straight inlet/ outlet pipes (calming sections) are not required for the flow sensor. The energy meter can be installed in both horizontal and vertical pipe sections, but every time so that air bubbles cannot collect in the flow sensor. We recommend installing the flow sensor in a tilted position (45 ). Make sure the energy meter is installed sufficiently far away from possible sources of electromagnetic interference (switches, electric motors, fluorescent lamps, etc.). For cooling application and for medium temperatures more than 90 C, the calculator must be mounted on the wall at a sufficient distance away from heat sources using the holder supplied. It is recommended that stop valves be fitted before and after the energy meter to simplify dismantling the energy meter. The energy meter should be installed in a convenient position for service and operating personnel. For the further information pls. refer to the SONOMETER 1100 s instructions. DEN-SMT/PL VD.SH.J8.02 Danfoss 01/15 11

12 Ød Data Sheet Dimensions L2 R AGV AGZ h H L L1 B ØD K Ø L1 L1 F Nominal size q p = 0.6 m³/ h q p = 1.5 m³/ h q p = 2.5 m³/ h q p = 3.5 m³/ h q p = 6 m³/ h q p = 10 m³/ h q p = 15 m³/ h q p = 25 m³/ h q p = 40 m³/ h q p = 60 m³/ h L [mm] L1 [mm] L2 [mm] B [mm] R [mm] H [mm] h [mm] G¾B G1B G1B FL G¾B G1B G1B FL G1B G1B FL G1¼B FL FL G1¼B FL FL G2B FL FL FL FL FL AGZ AGV R½ R¾ R¾ - R½ R¾ R¾ - R¾ R¾ - R1 - - R1 - - R1½ D [mm] d [mm] F [mm] K [mm] Weight [kg] VD.SH.J8.02 Danfoss 01/15 DEN-SMT/PL

13 Dimensions, continued Temperature sensors Installation Type Diameter D (mm) Length L (mm) Immersed (direct) or in pocket (indirect) Pt 500 ø Sensor pockets Type Brass Stainless steel Sensor diameter (mm) ø 5.2 ø 5.2 Length L1 (mm) L (mm) Ball valves Dimension IG (mm) Length L (mm) Height B (mm) G ½ G ¾ G Tailpieces Dimension AGV AGZ Length L (mm) Overall length L 1 (mm) R ½ G ¾ B 35 44,5 AGV AGZ R ¾ G 1 B 47, 5 59 R 1 G 1¼ B 47, 5 60,5 L L1 R 1½ G 2 B DEN-SMT/PL VD.SH.J8.02 Danfoss 01/15 13

14 14 VD.SH.J8.02 Danfoss 01/15 DEN-SMT/PL

15 DEN-SMT/PL VD.SH.J8.02 Danfoss 01/15 15

16 16 VD.SH.J8.02 Produced by Danfoss A/S 01/15

SONOMETER TM 1100 Ultrasonic compact energy meter

SONOMETER TM 1100 Ultrasonic compact energy meter Data sheet SONOMETER TM 1100 Ultrasonic compact energy meter Description/Application MID examination certificate no. : DE-10-MI004-PTB003 The SONOMETER 1100 is an ultrasonic static compact energy meter

More information

INFOCAL 8 Energy calculator

INFOCAL 8 Energy calculator Data sheet INFOCAL 8 Energy calculator Description/Application MID examination certificate no.: DE-10-MI004-PTB008 The INFOCAL 8 is an energy calculator e.g. for combination with SONO 1500 CT especially

More information

SONOMETER TM 1000 Ultrasonic compact heat meter

SONOMETER TM 1000 Ultrasonic compact heat meter SONOMETER TM 1000 Ultrasonic compact heat meter Description/Application The SONOMETER 1000 is a static compact heat meter with fully electronic measurement based on the ultrasonic principle. It is especially

More information

SHARKY 775 ULTRASONIC COMPACT METER. 4 Approved according EN 1434 and MID in class 2 with dynamic range of 1:250 (qi:qp) in class 2

SHARKY 775 ULTRASONIC COMPACT METER. 4 Approved according EN 1434 and MID in class 2 with dynamic range of 1:250 (qi:qp) in class 2 APPLICATION ultrasonic compact energy meter can be used for measuring the energy consumption in heating / cooling application for billing purposes. The measurement principle is static and based on the

More information

SHARKY 775 ULTRASONIC COMPACT METER. 4 Approved according EN 1434 and MID in class 2 with dynamic range of 1:250 (qi:qp) in class 2

SHARKY 775 ULTRASONIC COMPACT METER. 4 Approved according EN 1434 and MID in class 2 with dynamic range of 1:250 (qi:qp) in class 2 APPLICATION ultrasonic compact energy meter can be used for measuring the energy consumption in heating / cooling application for billing purposes. The measurement principle is static and based on the

More information

SHARKY 775 ULTRASONIC COMPACT METER. 4 Approval with dynamic range up to 1:250 (qi:qp) MID in class 2 (depends on meter size), standard 1:100

SHARKY 775 ULTRASONIC COMPACT METER. 4 Approval with dynamic range up to 1:250 (qi:qp) MID in class 2 (depends on meter size), standard 1:100 APPLICATION ultrasonic compact energy meter can be used for measuring the energy consumption in heating / cooling application for billing purposes. The measurement principle is static and based on the

More information

SONO 1500 CT Ultrasonic flow sensor

SONO 1500 CT Ultrasonic flow sensor Data sheet SONO 1500 CT Ultrasonic flow sensor Description/Application MID examination certificate no.: DE-09-MI004-PTB011 The SONO 1500 CT is an ultrasonic flow sensor especially designed for heating,

More information

Brunata Optuna H. Properties. Counter

Brunata Optuna H. Properties. Counter Brunata Optuna H Brunata Optuna H measures energy consumption in large and small heating and cooling systems as well as combined heating and cooling systems. The meter is compact and belongs to the first

More information

Infocal 9 Energy calculator

Infocal 9 Energy calculator Infocal 9 Energy calculator Description/Application MID examination certificate no.: LT-1621-MI004-028 The INFOCAL 9 is an energy calculator, e.g. for combination with or SonoSensor 30. It is especially

More information

SonoMeter 31 Energy Meters

SonoMeter 31 Energy Meters SonoMeter 31 Energy Meters Description MID examination certificate no.: LT-1621-MI004-023 The Danfoss SonoMeter 31 is a range of ultrasonic, compact energy meters intended for measuring energy consumption

More information

RAY COMPACT ENERGY METER MECHANICAL

RAY COMPACT ENERGY METER MECHANICAL APPLICATION Fully electronic compact heat meter or compact cooling and heat meter with impeller scanning for recording energy and volume data. Highly accurate recording of all billing data in a heating

More information

RAY MECHANICAL COMPACT METER. 4 MID approved class 2 from ND 15 mm qp 0,6 m3/h up to ND 40 mm qp 10 m3/h

RAY MECHANICAL COMPACT METER. 4 MID approved class 2 from ND 15 mm qp 0,6 m3/h up to ND 40 mm qp 10 m3/h APPLICATION Ray is a fully electronic multi-jets compact heat meter or compact cooling and heat meter with impeller scanning for recording energy and volume data. Ray is equipped with 2 temperature sensors.

More information

RAY MC COMPACT ENERGY METER MECHANICAL

RAY MC COMPACT ENERGY METER MECHANICAL APPLICATION Fully electronic measuring capsule heat meter, heat and cooling meter or cooling meter with impeller scanning for volume measuring and energy calculation. Highly accurate recording of all billing

More information

Instruction. SONOMETER 1100 Ultrasonic compact energy meter. 1.0 Table of contents. 2.0 Safety notes and product information

Instruction. SONOMETER 1100 Ultrasonic compact energy meter. 1.0 Table of contents. 2.0 Safety notes and product information Instruction SONOMETER 1100 Ultrasonic compact energy meter 1.0 Table of contents 1.0 Table of contents...1 2.0 Safety notes and product information...1 3.0 Installation of energy meter...2 4.0 Installation

More information

Instruction. INFOCAL 8 Energy calculator. 1.0 Table of contents. 2.0 Safety notes and product information

Instruction. INFOCAL 8 Energy calculator. 1.0 Table of contents. 2.0 Safety notes and product information Instruction INFOCAL 8 Energy calculator 1.0 Table of contents 1.0 Table of contents...1 2.0 Safety notes and product information...1 3.0 Installation of energy calculator...2 4.0 Installation of temperature

More information

ULTRASONIC D. Compact ultrasonic heat meter

ULTRASONIC D. Compact ultrasonic heat meter ULTRASONIC D Compact ultrasonic heat meter Applications ULTRASONIC D is a compact ultrasonic heat meter used for measuring energy in heating and cooling plants in facility management systems as well as

More information

RAY MC COMPACT ENERGY METER MECHANICAL

RAY MC COMPACT ENERGY METER MECHANICAL APPLICATION Fully electronic measuring capsule heat meter, heat and cooling meter or cooling meter with impeller scanning for volume measuring and energy calculation. Highly accurate recording of all billing

More information

Brunata Optuna H Ultrasonic energy meter Type 775 Installation Guide Edition 1.2

Brunata Optuna H Ultrasonic energy meter Type 775 Installation Guide Edition 1.2 Ultrasonic energy meter Type 775 Installation Guide Edition 1.2 UK-QB101575 / 29.05.2012 Brunata a/s is a Danish owned company. We have more than 90 years of experience within developing and producing

More information

HDU-SF (Horizontal Distribution Units - Single Flat)

HDU-SF (Horizontal Distribution Units - Single Flat) MAKING MODERN LIVING POSSIBLE Service Guide www.heating.danfoss.com Danfoss A/S is not liable or bound by warranty if these instructions are not adhered to during installation or service. The English language

More information

SonoSelect 10 and SonoSafe 10 Energy Meters

SonoSelect 10 and SonoSafe 10 Energy Meters SonoSelect 10 and SonoSafe 10 Energy Meters Description The Danfoss SonoSelect 10 and SonoSafe 10 are ultrasonic compact energy meters intended for measuring energy consumption in heating and cooling applications

More information

EW447-EW452 Series Mechanical Heatmeters FOR HEATING AND COOLING APPLICATIONS

EW447-EW452 Series Mechanical Heatmeters FOR HEATING AND COOLING APPLICATIONS Design IEC870-6 EW447A0100 26757950 2252 00.02 Type440 Umgebungsklasse: C env: 5 C...105 C Δp: 3K...100K q: 1,5m 3 /h q: 0,03m 3 /h q: 3,0m 3 /h M-Bus kwh 2002 er: 5 C...90 C DN15 PN16 Rücklauf Pt500 Kl.

More information

SONOMETER 2000 Ultrasonic heat meter

SONOMETER 2000 Ultrasonic heat meter SONOMETER 2000 Ultrasonic heat meter Description/Application The SONOMETER 2000 is an ultrasonic heat meter especially designed for measuring the water and energy consumption in district heating networks.

More information

MULTICAL 302 DATA SHEET

MULTICAL 302 DATA SHEET MULTICAL 302 DATA SHEET On-site configurable as to inlet and outlet PN25 metal flow sensor, approved up to 130 C Small pressure loss, all flow sizes below 0.1 bar Dynamic range up to 1:1600 from start

More information

WESAN WP E ELECTRONIC METER WOLTMAN

WESAN WP E ELECTRONIC METER WOLTMAN APPLICATION Fully electronic bulk water meter for measuring the flow (cold water up to 30 C) in supply lines with high flow at low pressure loss. Highly accurate recording of all billing data. FEATURES

More information

SVM F27 Compact. Ultrasonic heatmeter. Data sheet

SVM F27 Compact. Ultrasonic heatmeter. Data sheet SVM F27 Compact Ultrasonic heatmeter Data sheet Application field F27 is a heat meter for debiting and monitoring heat energy consumption. F27 is a flexible compact heat meter with an ultra sonic flow

More information

SVM F27 / C27. Ultrasonic BTU meter for heating or cooling. Data sheet

SVM F27 / C27. Ultrasonic BTU meter for heating or cooling. Data sheet SVM F27 / C27 Ultrasonic BTU meter for heating or cooling Data sheet Application field F27/C27 is a BTU meter for debiting and monitoring energy consumption (F27 for heating and C27 for cooling). F27/C27

More information

Supercal 531 Multi function Integrator that lives up to Your highest expectations

Supercal 531 Multi function Integrator that lives up to Your highest expectations n Thermal Energy n Flow Metering n Supercal 531 Multi function Integrator that lives up to Your highest expectations Supercal 531 Multi functional integrator with unlimited options The Supercal 531 convinces

More information

Portfolio. and ULTRAWATER. Ultrasonic Static Meters. Ultrasonic Meters Residential and District Heating/ Cooling Water Measurement

Portfolio. and ULTRAWATER. Ultrasonic Static Meters. Ultrasonic Meters Residential and District Heating/ Cooling Water Measurement Ultrasonic Meters Residential and District Heating/ Cooling Water Measurement Ultrasonic Static Meters Portfolio ULTRAHEAT/ ULTRACOLD and ULTRAWATER The best of Landis+Gyr Ultrasonic Static Meters, for

More information

Heat meter Q heat 5 US

Heat meter Q heat 5 US Heat meter Q heat 5 US Ultrasonic heat meter with ultrasonic measurement technology (runtime difference method) with IrDA interface and an interface for retrofitting external modules. Exact measurement

More information

MULTICAL 403. Data sheet

MULTICAL 403. Data sheet - Data sheet MULTICAL 403 Programmable data logger with AMR Configurable M-Bus modules with logger reading On-site configuration via front keys Highly flexible modular design Pulse inputs and pulse outputs

More information

Electronic Heating Energy Meters

Electronic Heating Energy Meters 5 333 SIEMECA Electronic Heating Energy Meters WFM... WFQ... Electronic, mains-independent meters to acquire heating energy consumption in autonomous heating and domestic hot water plants. Storage and

More information

MULTICAL Energy meter TS PTB. Application

MULTICAL Energy meter TS PTB. Application MULTICAL Energy meter Can be connected to flow meters from qp 0.6 to 3000 m 3 /h Additional connection for electricity or water meters Measures heat or cooling Leak detection Battery back-up Data logging

More information

MULTICAL 601 DATA SHEET

MULTICAL 601 DATA SHEET Precise measuring of heat and cooling up to 3000 m³/h Pt100, 2-wire Pt500, 2- and 4-wire Available with ULTRAFLOW from q p 0.6 to 1000 m³/h 24 VAC, 230 VAC or 10 years battery supply Data logging for 460

More information

US-W/V US-S/FFL. Certificate No.: DE-09-MI004-PTB018 (MID heat) / 22.72/09.01 (National German cooling)

US-W/V US-S/FFL. Certificate No.: DE-09-MI004-PTB018 (MID heat) / 22.72/09.01 (National German cooling) Installation and Operating Instructions Calculator with Ultrasonic flow sensor: Heat Meter, Cooling Meter, Combined Heat / Cooling Meter US-W/V US-S/FFL Certificate No.: DE-09-MI004-PTB018 (MID heat) /

More information

SVM F22. Calculator for heating or cooling applications. Data sheet

SVM F22. Calculator for heating or cooling applications. Data sheet SVM F22 Calculator for heating or cooling applications Data sheet Application area F22 is a flexible calculator designed for measuring and monitoring of small to medium-sized heating or cooling installations.

More information

ULTRAHEAT / ULTRACOLD T330. The Evolutionary. Ultrasonic Heat Meter / Cooling Meter. Ultrasonic Heat Meter / Cooling Meter.

ULTRAHEAT / ULTRACOLD T330. The Evolutionary. Ultrasonic Heat Meter / Cooling Meter. Ultrasonic Heat Meter / Cooling Meter. Ultrasonic Heat Meter / Cooling Meter Residential Ultrasonic Heat Meter / Cooling Meter The Evolutionary ULTRAHEAT / ULTRACOLD T330 Proven technology one step further T330 COMPACT Versatile installation

More information

Siemens Switzerland Ltd HVAC Products. SIEMECA Electronic Heat and Cooling Meters

Siemens Switzerland Ltd HVAC Products. SIEMECA Electronic Heat and Cooling Meters 5 338 SIEMECA Electronic Heat and Cooling Meters WFR WFN Electronic, mains-independent meters to acquire the heat and cooling energy consumption in autonomous heating, cooling and domestic hot water plants.

More information

Installation and Operating Instructions Compact Heat Meter Compact Heat / Cooling Meter Amtron

Installation and Operating Instructions Compact Heat Meter Compact Heat / Cooling Meter Amtron Installation and Operating Instructions Compact Heat Meter Compact Heat / Cooling Meter Amtron 1 Application and function This heat meter or heat / cooling meter is designed for the measurement of the

More information

ULTRAHEAT / ULTRACOLD T330. The Evolutionary. Ultrasonic Heat Meter / Cooling Meter. Ultrasonic Heat Meter / Cooling Meter.

ULTRAHEAT / ULTRACOLD T330. The Evolutionary. Ultrasonic Heat Meter / Cooling Meter. Ultrasonic Heat Meter / Cooling Meter. Ultrasonic Heat Meter / Cooling Meter Residential Ultrasonic Heat Meter / Cooling Meter The Evolutionary ULTRAHEAT / ULTRACOLD T330 Proven technology one step further T330 COMPACT Versatile installation

More information

ultego III smart plus

ultego III smart plus Ultrasonic heating and cooling meter ultego III smart plus Residential ultego III smart plus Technical description 32 22 101 001 a Date: 07.04.2017 ista Middle East FZE Outstanding features 2/26 Outstanding

More information

Installation & User Guide. Multical 402. (Heating & Cooling) Supplied by. .com. Call us on +44 (0)

Installation & User Guide. Multical 402. (Heating & Cooling) Supplied by. .com. Call us on +44 (0) Installation & User Guide Multical 402 (Heating & Cooling) Supplied by.com Call us on +44 (0)118 916 9420 Email info@247able.com Installation and User Guide MULTICAL 402 Kamstrup A/S Industrivej 28, Stilling

More information

MULTICAL 403. Data sheet

MULTICAL 403. Data sheet Data sheet MULTICAL 403 Programmable data logger with AMR Conigurable M-Bus modules with logger reading On site coniguration via front keys Highly lexible modular design Pulse inputs and pulse outputs

More information

microclima Single Jet SENSOSTAR 2/2+ DE-07-MI004-PTB025 (MID, heat)

microclima Single Jet SENSOSTAR 2/2+ DE-07-MI004-PTB025 (MID, heat) Installation and Operating Instructions Compact Heat Meter Compact Heat / Cooling Meter microclima Single Jet SENSOSTAR 2/2+ DE-07-MI004-PTB025 (MID, heat) 1 Application and function This heat meter or

More information

MULTICAL 603. Data sheet. The future-proof heat and cooling meter with full flexibility

MULTICAL 603. Data sheet. The future-proof heat and cooling meter with full flexibility Data sheet MULTICAL 603 The future-proof heat and cooling meter with full flexibility Fully programmable data logger with minute loggers 2 second integration interval 16 years battery lifetime at a reading

More information

Flow Measurement SITRANS F US Inline

Flow Measurement SITRANS F US Inline Flowmeter SITRANS FUE80 with CT approval Overview The 2-path flowmeter SITRANS FUE80 comes as battery or mains-powered and is designed to measure water flow in district heating plants, local networks,

More information

User s Manual. F2 Calculator. A metering component for thermal energy applications

User s Manual. F2 Calculator. A metering component for thermal energy applications User s Manual F2 Calculator A metering component for thermal energy applications Rev 08.24.2007 1 Installation 1.1 At delivery F2 calculators are delivered in the Transport Mode. Only the clock is active

More information

MULTICAL 603. Data sheet. The future-proof heat and cooling meter with full flexibility

MULTICAL 603. Data sheet. The future-proof heat and cooling meter with full flexibility Data sheet MULTICAL 603 The future-proof heat and cooling meter with full flexibility Fully programmable data logger with minute loggers 2 second integration interval 16 years battery lifetime at a reading

More information

Q water 5.5. Electronic water meter. Data sheet DST1-QWA5-EN0 WMEAP / V 2.1

Q water 5.5. Electronic water meter. Data sheet DST1-QWA5-EN0 WMEAP / V 2.1 Data sheet / 3.3.2017 - V 2.1 Electronic water meter Q water 5.5 Electronic MID-conform water meter for determining water consumption in water supply systems The electronic water meter Q water 5.5 has

More information

Flow Measurement SITRANS F US Inline

Flow Measurement SITRANS F US Inline Flowmeter SITRANS FUS80 standard Overview Design The -path design of SITRANS FUS80 ensures maximum accuracy under short inlet conditions. The flowmeter consists of a flow sensor pipe, 4 transducers/transducer

More information

SVM F27 Compact. Compact heat meter. Users manual

SVM F27 Compact. Compact heat meter. Users manual SVM F27 Compact Compact heat meter Users manual Users manual 1 INSTALLATION... 5 1.1 CONNECTION AND MOUNTING... 5 1.1.1 Flow part, mounting... 5 1.1.2 Temperature sensors, mounting... 5 1.1.3 Calculator,

More information

Technical Description MULTICAL 302. Kamstrup A/S Industrivej 28, Stilling DK-8660 Skanderborg T: kamstrup.

Technical Description MULTICAL 302. Kamstrup A/S Industrivej 28, Stilling DK-8660 Skanderborg T: kamstrup. Technical Description Kamstrup A/S Industrivej 28, Stilling DK-8660 Skanderborg T: +45 89 93 10 00 info@kamstrup.com kamstrup.com 2 Kamstrup A/S Technical Description 5512-1334_F1_GB_12.2016 Contents 1

More information

Applications. Features RESIDENTIAL ULTRASONIC WATER METER. Revenue metering Residential submetering Commercial buildings.

Applications. Features RESIDENTIAL ULTRASONIC WATER METER. Revenue metering Residential submetering Commercial buildings. MEASURE TODAY. ENSURE TOMORROW wprime TM Series 280W-R Applications Revenue metering Residential submetering Commercial buildings Leakage detection AMR / AMI and billing Drive-by metering Features Residential

More information

ph or ORP Transmitter

ph or ORP Transmitter ph or ORP Transmitter Programmable outputs: two transistor and single or dual analog 4-20 ma (Process + Temp) Removable backlighted display Universal process connection Compatible with 120 mm ph/ ORP probes

More information

ULTRAHEAT T230 ULTRACOLD T230

ULTRAHEAT T230 ULTRACOLD T230 Ultrasonic heating and cooling meter T230 Residential ULTRAHEAT T230 ULTRACOLD T230 Technical description 32 18 101 001 d Date: 15.01.2017 Landis+Gyr GmbH Outstanding features 2/26 Outstanding features

More information

Ultrasonic heat and cooling energy meters

Ultrasonic heat and cooling energy meters Ultrasonic heat and cooling energy meters UH50.. Ultrasonic heat and cooling energy meters to measure flow and energy in hydronic heating or refrigerant circuits. Available as heat, cooling energy, or

More information

SVM F2 Calculator. A small competent calculator for compact or wall montage. Users manual

SVM F2 Calculator. A small competent calculator for compact or wall montage. Users manual SVM F2 Calculator A small competent calculator for compact or wall montage Users manual Users manual F2 1 INSTALLATION... 5 1.1 AT DELIVERY... 5 1.2 CONNECTIONS... 6 2 MOUNTING... 7 2.1 MOUNTING ON A

More information

12/2 Product overview. 12/3 7KT1 14, 7KT1 53 E-counters. 12/9 7KT1 11, 7KT1 12 digital measuring devices. 12/11 7KT1 0 analog measuring devices

12/2 Product overview. 12/3 7KT1 14, 7KT1 53 E-counters. 12/9 7KT1 11, 7KT1 12 digital measuring devices. 12/11 7KT1 0 analog measuring devices BETA Measuring /2 Product overview /3 7KT1 14, 7KT1 53 E-counters /9 7KT1 11, 7KT1 digital measuring devices /11 7KT1 0 analog measuring devices / 7KT5 8 time and pulse counters /14 7KT5 5, 7KT5 6 time

More information

1.2 M-Bus (optional) The M-Bus is a galvanically isolated interface for the transmission of meter data (absolute values).

1.2 M-Bus (optional) The M-Bus is a galvanically isolated interface for the transmission of meter data (absolute values). Operating Instructions Communication Interfaces 1 Interfaces and Options 1.1 Optical (infrared) interface For communication with the optical interface an optocoupler and the Device Monitor software are

More information

MULTICAL 602 DATA SHEET

MULTICAL 602 DATA SHEET Complete range of communication modules High Power RadioRouter module Data loggers Info loggers Data backup in case of power failure EN 1434 MID-2004/22/EC M11 0200 Heat and cooling meters with unlimited

More information

microclima/sensostar 2/2+ MSH

microclima/sensostar 2/2+ MSH Installation and Operating Instructions Thermal Energy Meter (Compact Heat Meter, Combined Heat/Cooling Energy Meter) microclima/sensostar 2/2+ MSH Model MSH DE-07-MI004-PTB001 (MID heat) Model QStar DE-08-MI004-PTB005

More information

SITRANS F flowmeters SITRANS F US. Transmitter FUS080. 4/194 Siemens FI

SITRANS F flowmeters SITRANS F US. Transmitter FUS080. 4/194 Siemens FI Overview The transmitter is available in an IP67/NEMA X/6 enclosure and is designed for use in the flowmeters series: SONOKIT (1- or 2-track) FUS380 (2-track) FUE380 (2-track) The transmitter FUS080 is

More information

S103C ELECTROMAGNETIC FLOW METERS. Main application fields MOUNTING

S103C ELECTROMAGNETIC FLOW METERS. Main application fields MOUNTING ELECTROMAGNETIC FLOW METERS The electromagnetic flow meter is used to measure the flow rate of conductive fluids and waste water. The measurement is independent of the density, viscosity, temperature and

More information

flowiq 3100 Data sheet

flowiq 3100 Data sheet Data sheet flowiq 3100 Pinpoint accuracy Vacuum sealed construction Drive-by or network Long range Long life Built-in Wireless M-Bus Simple installation Contents Approved meter data 4 Material 4 Technical

More information

SITRANS F flowmeters SITRANS F US. Flowmeter FUE380 with approval. 4/230 Siemens FI Overview

SITRANS F flowmeters SITRANS F US. Flowmeter FUE380 with approval. 4/230 Siemens FI Overview SITRANS F flowmeters Siemens AG 009 Overview The -track flowmeter SITRANS FUE380 comes as battery or mains-powered and is designed to measure water flow in district heating plants, local networks, boiler

More information

Flow Switch - 2 programmable thresholds. Stand Alone (Battery) - Battery powered, - 2 totalizers display, - Local flow display,

Flow Switch - 2 programmable thresholds. Stand Alone (Battery) - Battery powered, - 2 totalizers display, - Local flow display, DN 15 - DN 50; PN Advantages / Benefits Easy System integration by Easy LINK provides low cost of ownership Easy commissioning due to multi-language, menu-guided operation TEACH-IN: automatic calibration

More information

MULTICAL 602. Data sheet. Heat and cooling meters with unlimited communication

MULTICAL 602. Data sheet. Heat and cooling meters with unlimited communication Data sheet MULTICAL 602 Heat and cooling meters with unlimited communication Complete range of communication modules High Power RadioRouter module Data loggers Info loggers Data backup in case of power

More information

Applications. Features RESIDENTIAL ULTRASONIC WATER METER. Revenue metering Residential submetering Commercial buildings.

Applications. Features RESIDENTIAL ULTRASONIC WATER METER. Revenue metering Residential submetering Commercial buildings. MEASURE TODAY. ENSURE TOMORROW wprime TM Series 280W-D Applications Revenue metering Residential submetering Commercial buildings Leakage detection AMR / AMI and billing Drive-by metering Features Residential

More information

Flow Measurement. SITRANS F US Inline. Flowmeter SITRANS FUS380 standard. 4/254 Siemens FI Overview

Flow Measurement. SITRANS F US Inline. Flowmeter SITRANS FUS380 standard. 4/254 Siemens FI Overview Flowmeter SITRANS FUS380 standard Overview Design The 2-track design of SITRANS FUS380 ensures maximum accuracy under short inlet conditions. The flowmeter consists of a flow sensor pipe, transducers/transducer

More information

Release A Member of the

Release A Member of the Release 4.02 A T u n e d GRID M e a s u r e A Member of the GRID GRID The OCTAVE Ultrasonic Meters A revolutionary, precise and ultra reliable ultrasonic bulk water meter with no moving parts. With superior

More information

Electronic device for recording the share of heat output by radiators.

Electronic device for recording the share of heat output by radiators. Data sheet / 7.5.2018 - V 2.6 Q caloric 5.5 Electronic device for recording the share of heat output by radiators. In terms of measuring technology, the Q caloric 5.5 is 100% compatible with the Q caloric

More information

ULTRAFLOW. Application. Cooling flow sensor. Ultrasonic flow sensor. Compact design. Static meter with no moving parts. Large dynamic range.

ULTRAFLOW. Application. Cooling flow sensor. Ultrasonic flow sensor. Compact design. Static meter with no moving parts. Large dynamic range. ULTRAFLOW Cooling flow sensor Ultrasonic flow sensor Compact design Static meter with no moving parts Large dynamic range No wear Exceptionally accurate Longevity Application ULTRAFLOW type 65-T is a static

More information

flowiq 3100 Data sheet

flowiq 3100 Data sheet Data sheet Nominal flow from 1.6 m³/h up to 100 m³/h Approved with dynamic range up to R400 'Drive-by', network or IoT Pinpoint accuracy Designed for operation in submerged environments Integrated communication

More information

JUMO Wtrans E01. Measuring probe for humidity, temperature, and CO 2 with wireless data transmission. Brief description. Universal Wtrans receiver

JUMO Wtrans E01. Measuring probe for humidity, temperature, and CO 2 with wireless data transmission. Brief description. Universal Wtrans receiver Page 1/13 JUMO Wtrans E01 Measuring probe for humidity, temperature, and CO 2 with wireless data transmission Humidity from 0 to 100 % RH (incl. -40 to +80 C) or CO 2 from 0 to 2000/5000/10000 ppm or Temperature

More information

Device Manual Chapter 4.1-R optosonic u 3 radio net

Device Manual Chapter 4.1-R optosonic u 3 radio net Chapter 4.1-R optosonic u 3 radio net L.83.0072 - Release 8.0.1 CH 2013 Nur für den internen Gebrauch For internal use only Uniquement pour utilisation interne http://www.ista.com Table of contents 1 Device

More information

mass flowmeter for compressed air

mass flowmeter for compressed air mass flowmeter for compressed air VARIOMASS MF High End electronic for air measurement & analyse - 1 - The VARIOMASS flow meter for compressed air is a comfortable system for air mass flow measurement,

More information

6000 W, 2450 MHz Microwave Generator GMP 60K SM 56T400 FST 3 IR

6000 W, 2450 MHz Microwave Generator GMP 60K SM 56T400 FST 3 IR 6000 W, 2450 MHz Microwave Generator GMP 60K SM 56T400 FST 3 IR Power supply It is based upon the latest switch mode power supply technology, offering size reduction (smallest 6 kw available on the market,

More information

Price list 2018 Devices

Price list 2018 Devices Price list 2018 Devices Product range Chapter Chapter name System overview Page 1 1 Heat cost allocator - Q caloric 3 1.1 New installation - Standard exchange - Conversion installation (P2 + AL2) 4 1.2

More information

Model Sono-Trak Transit Time

Model Sono-Trak Transit Time Model Sono-Trak Transit Time Ultrasonic Flow Meter Engineered for performance excellence, the Sono-Trak Transit Time ultrasonic meter combines non-invasive, bi-directional measurement with advanced ultrasonic

More information

Annex to application for conformity assessment of Heat meters in accordance with MID

Annex to application for conformity assessment of Heat meters in accordance with MID This is Annex No. 1 Dated: To application dated: Company Signed Documentation required (to be completed by applicant) for testing of Heat meter or sub-assemblies Note: All documentation must be equipped

More information

SITRANS F US SONOCAL series 3000

SITRANS F US SONOCAL series 3000 s Handbook series 3000 Ultrasonic heat meter and flowmeter The ultrasonic heat meter series 3000 is an ideal combination of a SITRANS F US SONOFLO ultrasonic flowmeter, a energy calculator type SITRANS

More information

Operating manual IMPORTANT! READ CAREFULLY BEFORE USE. KEEP FOR THE ENTIRE LIFE OF THE PRODUCT. Heat meters. Deltamess TKS-WM compact heat meter

Operating manual IMPORTANT! READ CAREFULLY BEFORE USE. KEEP FOR THE ENTIRE LIFE OF THE PRODUCT. Heat meters. Deltamess TKS-WM compact heat meter Operating manual IMPORTANT! READ CAREFULLY BEFORE USE. KEEP FOR THE ENTIRE LIFE OF THE PRODUCT. Heat meters Deltamess TKS-WM compact heat meter 1 Contents Safety and warranty... 3 Radio system... 3 Lithium

More information

Measurement. SITRANS F US Inline. 3/262 Siemens FI Transmitter SITRANS FUS080/FUE080

Measurement. SITRANS F US Inline. 3/262 Siemens FI Transmitter SITRANS FUS080/FUE080 Overview The transmitter is available in an IP67/NEMA 4X/6 enclosure and is designed for use in the flowmeters series: SONOKIT (1-path or -path) FUS80 (-path) FUE80 (-path) The transmitter FUS080 is always

More information

ULTRAFLOW TS PTB. Application. Ultrasonic flow sensor. Compact design. Static meter with no moving parts. Large dynamic range.

ULTRAFLOW TS PTB. Application. Ultrasonic flow sensor. Compact design. Static meter with no moving parts. Large dynamic range. Ultrasonic flow sensor Compact design D a t a s h e e t Static meter with no moving parts Large dynamic range No wear Exceptionally accurate Longevity TS 27.01 113 OIML R75 Application TS 27.01 109 DS/EN

More information

SITRANS F flowmeters. SITRANS F System information MAGFLO electromagnetic flowmeters 4/9

SITRANS F flowmeters. SITRANS F System information MAGFLO electromagnetic flowmeters 4/9 Overview MAGFLO family MAGFLO electromagnetic are designed for measuring the flow of electrically conductive mediums. The patented MAGFLO Verificator guarantees accurate measurement and simple verification.

More information

SITRANS F flowmeters SITRANS F M. Transmitter Transmag 2 with sensor 911/E 4/77. Overview

SITRANS F flowmeters SITRANS F M. Transmitter Transmag 2 with sensor 911/E 4/77. Overview Overview Design The complete flowmeter consists of a flow sensor and an associated transmitter from the Transmag 2 for pulsed alternating field. These are available as remote and compact versions ( 911/E

More information

Electromagnetic Flow Transmitter

Electromagnetic Flow Transmitter Electromagnetic Flow Transmitter Sensor in solid state technology Working as a transmitter and/or as an On/Off controller Automatic-calibration of full scale: Teach-In Clean in place (CIP) Type can be

More information

Digital flow transmitter for continuous flow measurement

Digital flow transmitter for continuous flow measurement Digital flow transmitter for continuous flow measurement Compact or remote version for DN 06 to 400, PN10 Shows both flow rate and volume (with two totalizers) Automatic-calibration: TEACH-IN Simulation:

More information

The innovative way forward symphonic sensor net radio system

The innovative way forward symphonic sensor net radio system The innovative way forward symphonic sensor net radio system Radio system technology The symphonic sensor net radio system Applications at a glance Heat cost allocation meter doprimo 3 radio net Smoke

More information

OPTIFLUX 1000 Technical Datasheet

OPTIFLUX 1000 Technical Datasheet OPTIFLUX 1000 Technical Datasheet Electromagnetic flow sensor in sandwich design Lightweight and compact Excellent price performance ratio Quick and easy to install The documentation is only complete when

More information

TMU. Coriolis Mass Flow Meter. for liquids and gas

TMU. Coriolis Mass Flow Meter. for liquids and gas Coriolis Mass Flow Meter for liquids and gas measuring monitoring analysing TMU S5 OO Measuring range: 0-60 kg/h 0-2200 t/h water OO Accuracy: ± 0.1% of reading ±zero point stability (from liquids up to

More information

INLINE flowmeter for continuous flow measurement

INLINE flowmeter for continuous flow measurement INLINE flowmeter for continuous flow measurement Economic integration in pipe systems without any additional piping 3-wire frequency pulse version to directly interface with PLC s (both PNP and NPN) Connection

More information

Smart Mobile Metering Solutions WALK-BY OR DRIVE-BY READING HYDRUS SMART METERS AND IZAR SYSTEM COMPONENTS

Smart Mobile Metering Solutions WALK-BY OR DRIVE-BY READING HYDRUS SMART METERS AND IZAR SYSTEM COMPONENTS Smart Mobile Metering Solutions WALK-BY OR DRIVE-BY READING HYDRUS SMART METERS AND IZAR SYSTEM COMPONENTS Faster accurate information with Enware Smart Mobile Metering Providing the ability to collect

More information

Mx-D15 Intelligent Valve Actuator

Mx-D15 Intelligent Valve Actuator Application Small radio controlled, battery-powered actuator for room temperature control. For thermostat valve bodies for direct mounting on commercially available radiator valves for room-specific temperature

More information

Size : Connection End : Min Temperature : Max Temperature : Materials : Cast iron body

Size : Connection End : Min Temperature : Max Temperature : Materials : Cast iron body Size : Connection End : Min Temperature : Max Temperature : DN 50 to 200 Flanged R.F. PN10/16 0 C ( for cold water type ) + 90 C (for hot water type ) Max Pressure : 16 Bars Specifications : Horizontal

More information

Electromagnetic Flowmeter Comet F

Electromagnetic Flowmeter Comet F Electromagnetic Flowmeter Comet F - Exact measurements - Comfortable calibration with PC - No setup elements - No pressure loss - Periodic cleaning of electrodes - Data backup during power failure - Communication

More information

HMM/CHW CHW Heat Meters

HMM/CHW CHW Heat Meters Data Sheet HMM/CHW CHW Heat Meters CHW Heat Meters (Energy Integrator complete with Mechanical Battery Powered Flow Part) Battery powered with LCD data display, pulse output, for return pipe installation

More information

Energy Meters for DIN Rail Mounting Electric energy meter WS0101, WS0102,WS1102 WS0301, WS0302,WS1302

Energy Meters for DIN Rail Mounting Electric energy meter WS0101, WS0102,WS1102 WS0301, WS0302,WS1302 Energy Meters for DIN Rail Mounting Electric energy meter WS0101, WS0102,WS1102 WS0301, WS0302,WS1302 Direct connection up to 65 A (WSx10x) Connection with current transformer (WSx30x) Industrial or meters

More information

FLOMID FX Electromagnetic Flowmeter

FLOMID FX Electromagnetic Flowmeter FLOMID FX Electromagnetic Flowmeter Working pressure manufacturing according to PED 97/23/CE (Lloyd s Register Certificate Nº 031) Introduction Modular design in two versions: Compact, sensor and electronics

More information

Metering systems 0527EN January 2014 Sanitary water meter, GE552-2 series Versions for wireless centralisation

Metering systems 0527EN January 2014 Sanitary water meter, GE552-2 series Versions for wireless centralisation 07EN March 0 Sanitary water meters GE55- series 00A/ Qualitative error diagram % error 5 0 - - - - -5 Q Q Q Q GE55Y90 GE55Y9 Installation Q [m /h] Q [m /h] Q [m /h] Q [m /h] Description Single-jet dry

More information

Warranty conditions are available on this website: only in English version

Warranty conditions are available on this website:   only in English version THE MOST ACCURATE BATTERY POWERED SYSTEM FLOWIZ ( M L 2 5 2 ) C O N V E R T E R W I T H B A T T E R Y S U P P L Y Warranty conditions are available on this website: www.isomag.eu only in English version

More information