1 mass flowmeter for compressed air VARIOMASS MF High End electronic for air measurement & analyse - 1 -

2 The VARIOMASS flow meter for compressed air is a comfortable system for air mass flow measurement, which consists of a thermal dispersion sensor and the remote electronic. Customers can use it for accurate compressed air mass flow measurements line size between ½ up to 2 as In-Line sensor with a complete flow body. Furthermore allows it the employment for pipe sizes from 65 mm up to 500 mm as an insertion sensor. Compared with the reliable VARIOMASS air mass flow measurement system do we supply a new field electronic called VARIOMASS MF, which allows simultaneous signal processing of 1 up to 4 sensors. The 4 inputs can use with 4 different mass flow sensors and are moreover able to determine other inputs such as temperature, pressure, relative humidity or dew point sensor. There exist analog and digital outputs for every sensor. The LCD display can simultaneously show for each channel the actual and total flow values. An integrated data logger to determine the current gas mass flow and consumption values is optionally available. This data logger can be read out with a serial interface by using the software VARLOG II. Besides the analog outputs we can supply a pulse output, two programmable relay contacts and digital interfaces like RS 232 and RS 485 optionally available. We additionally supply a digital input that can for example be used for recording the load and unloaded condition of one compressor. The big graphic display (dimensions B*H: 120*65 mm) may also be used for short time online recordings on every channel. This diagram works independent of the data logger and serves to control. The scale takes places over the full scale value of the input channel and dimension. The time period is fixed for about 30 minutes. Every channel can easily be chosen via the keyboard. The clear structured of the menu facilitates the use. A new achievement in the operation is the directly start of the data logger without input of start and stop time. The two counters were extended of the 12 totalizer that can record the air mass consumption per year for each month. A new function for an automatically zero adjustment has been added too. The insertion sensor (here with the option ball valve retractor assembly) can be chosen to measure the air mass consumption in pipe sizes from 65 mm up to 300 mm as sensor for input channel number one. fig.1): Insertion meter with option BVR ½ (ball valve retractor assembly) Additionally or alternatively In-Line sensors with fixed flow body for pipe sizes from ½ up to 2 (50 mm) can be chosen. Optionally is an integrated flow straighter with two plates with wholes for these In-Line sensors available. These can be used for short up and downstream area or for mobile measurements. The advantage of these In-Line sensors is higher measurement accuracy at small pipe diameters

3 TECHNICAL DATA Power supply Ambient temperature range: - 10 C up to + 50 C Protection class: Output signal: Flow units: Normal conditions (N): Media: 90 up to 240 VAC (optional 24 VDC) with max. 32 Watt IP 65 (NEMA 4X) aluminum enclosure with cable glands 0 / 4-20 ma linear equal to each flow range Nm³/h, Nm³/min., Nl/min., Nl/sec., kg/h, kg/min., SCFM, SCFH According to ISO 20 C & 1 bar abs. (optional other) Compressed air (Optional N2, O2, or other gases) Media temperature: 20 C (+/- 20 C) Optional 10 C up to C Media pressure: Max. process pressure: Process connection: Calibration accuracy (with necessary up- and downstream area) Turn down ratio: Repeatability 4 12 bar g. (Optional -1 bar g up to + 40 bar g.) 16 bar g. (Optional up to 40 bar g.) R ½" for Insertion Sensor ½ up to 2 NPT-M thread for In-Line Sensor (Optional DIN or ANSI flanges) 0 80 Nm/sec. (Optional 0 up to 200 Nm/sec.) +/- 2% of reading at turn down ratio of 100:1 within the pressure and temperature range 1:10 up to 1:1000 depends on flow rate +/- 0,5% of reading Wetted material: Stainless steel Pipe sizes In-Line Sensor with flow body for pipe size ½ up to 2 (Optional flow body up to pipe size 200 mm) Insertion Sensor from 65 mm up to 500 mm pipe size (Optional up to 1000 mm pipe size) Up- and Downstream area At least 10 x D and 5 x D, with flow conditioner only 3 x D and 2 x D with D = pipe inside diameter after a 90 elbow In-Line Sensor: Model Pipe size Inside Diameter Flow body Process Standard Flow ranges *** No. DN (Inch) Flow body Length L Thread (optional double) M-2 DN 15 (1/2 ) 15,8 mm 178 mm 1/2" NPT 0-20 Nm³/h (0,35 Nm³/min.) M-3 DN 20 (3/4") 20,9 mm 178 mm 3/4" NPT Nm³/h (1,65 Nm³/min.) M-4 DN 25 (1") 26,6 mm 203 mm 1" NPT Nm³/h (2,5 Nm³/min.) M-5 DN 32 ( 1 1/4") 35,1 mm 254 mm 1 1/4" NPT Nm³/h (4,15 Nm³/min.) M-6 DN 40 (1 1/2") 40,9 mm 381 mm 1 1/2" NPT Nm³/h (5,85 Nm³/min.) M-7 DN 50 (2") 52,5 mm 508 mm 2" NPT Nm³/h (10 Nm³/min.) Insertion Sensor: Model Pipe size * Inside diameter Total ** Process Standard Flow ranges *** No. DN (Inch) To DIN 2458 Flow Area Thread (optional double) M-0 DN 65 (2 1/2 ) 70,9 mm 1 m R ½" Nm³/h (15 Nm³/min.) M-0 DN 80 (3") 83,1 mm 1,2 m R ½" Nm³/h (23 Nm³/min.) M-0 DN 100 (4") 107,9 mm 1,6 m R ½" Nm³/h (38 Nm³/min.) M-0 DN 125 (5") 132,5 mm 2 m R ½ Nm³/h (58 Nm³/min.) M-1 DN 150 (6") 160,3 mm 2,4 m R ½ Nm³/h (83 Nm³/min.) M-1 DN 200 (8") 210,1 mm 3,1 m R ½" Nm³/h (150 Nm³/min.) M-1 DN 300 (12 ) 312,7 mm 4,7 m R ½ Nm³/h (333 Nm³/min.) M-1 DN 500 (20 ) 495,4 mm 7,4 m R ½ Nm³/h (833 Nm³/min.) * bigger pipe sizes on request ** total up- ad downstream area for 10 * D Up- plus 5 * D downstream behind a 90 elbow *** N = Normal Condition to ISO 1217 (20 C & 1 bar abs. & 0% relative humidity) other standard conditions on request - 3 -

4 DIMENSIONS Insertion Sensor: d = 1/2" L = 300 or 400 mm Dimensions of the Insertion meter Fig. 2): Insertion Sensor with Standard Swagelok fitting ½ and distance holder ring Fig. 3): Insertion Sensor with option BVR ½ and a security strap at Plexiglas pipe of 100 mm

5 In-Line Sensor: FLOW L di Fig. 4): In-Line Sensor for pipe size 2 (above) and 1 ½ ACCESSORIES Fig. 5): BVR ½ (ball valve retractor assembly) Fig. 6) flow body without and with flow conditioner - 5 -

6 OTHER SENSOR Pos. External Sensor range Unit Process Max. pressure Max. Temp. 1.0 Temperature 0 to C ½ 25 bar 100 C 1.1 Temperature - 25 to + 80 C ½ 10 bar 150 C 2.0 Pressure 0 10 Bar g ½ 25 bar 80 C 2.1 Pressure 0 40 Bar g. ½ 60 bar 80 C 2.2 Pressure Absolute mbar abs. ½ 1060 mbar 40 C 3.0 Rel. Humidity % ½ 10 bar 50 C 3.1 Rel. Humidity % ½ 25 bar 50 C 4.0 Dew point - 10 to + 50 C tp G ½ 20 bar 50 C 4.1 Dew Pont - 30 to + 20 C tp G ½ 20 bar 50 C 4.2 Dew Point - 80 to + 20 C tp G ½ 20 bar 50 C 5.0 Please quote maximally 3 additional sensors, thus the VARIOMASS MF electronics maximal four inputs own and the first one declared is with a mass flow sensor. The cable length of the additional sensors is the same as the one of mass flow sensor (6, 12, 24 metres or alternatively up to 100 meter). 4 mass flow sensors can also be employed for example to cover pipe sizes from ½ up to 500 mm pipe size or to manage 4 different flow applications with one evaluation electronic. Example: Humidity plus Temperature Sensor as combination for ambient air Options please indicate: flow conditioner for In-Line Sensor 24 VDC power supply of the electronic distance ring for Insertion Sensor BVR ½ with security strap carrying case for mobile measurements isolated inputs board External Sensor (number and specs.) Special calibration (i.e Nm/sec.) Gas name if not air (N 2, O 2, or other) for compressed air f dew point sensor pressure Sensor - 6 -

7 SOFTWARE The software VARLOG II will be delivered with the optional data logger. This program, which is based on MS Windows, can read out the saved data at the data logger of MF electronics with the serial interface. Besides this, the program is able to display the data as a diagram over the time. Furthermore is the user able to set the data logger in the device with this software. The memory of 8 MB is able to record the values in the device as long as 12 months at a chosen record time for each value every 60 seconds. At an insert of maximum numbers of sensors up to 5graphics (for example mass flow) can be represented on one mask. All graphics can be printed directly or the data can be exported to MS EXCEL or MS WORD

8 MODEL NUMBER M Pos. 1) number of Sensor 1-4 pcs. 1 = 1 Sensor, 2 = 2 Sensors aso. Pos. 2) 1 = without and 2 = with Data logger i.e. 42 means 4 Inputs with Data logger cable length Sensor - electronic: 06 = 6 meter (Standard) 12 = 12 meter 24 = 24 meter XX = XX meter (max. 100 meter) Output signal: 00 = Analog Output (Standard) I = pulse output M = M-Bus output K = Relay alarm contacts (2 pcs.) D = digital Input Process connection Sensor: 0 = Swagelok fitting ½ (Standard) bzw. NPT-thread for In-Line Sensor K = BVR ½ (not for In-Line Sensor) F = DIN flanges for In-Line Sensor Z = special Sensor material: S = stainless steel (Standard) pipe size / probe shaft length 0 = DN 65 to DN 300 / L = 300 mm or DN 65 to DN 125 with BVR ½ 1 = DN 300 to DN 500 / L = 400 mm or DN 125 to DN 300 with BVR ½ 2 = In-Line Sensor 1/2" (DN 12) 3 = In-Line Sensor 3/4" (DN 19) 4 = In-Line Sensor 1" (DN 25) 5 = In-Line Sensor 1 1/4" (DN 32) 6 = In-Line Sensor 1 1/2" (DN 38) 7 = In-Line Sensor 2" (DN 50) Z = special VAR MF E Dielen GmbH Zeppelinstr. 9 D Straelen / Germany Tel Fax info@dielen-gmbh.de

Instruction Manual. mass flow meter for compressed air. Druckluftbilanzierungssystem VARIOMASS VARIOMASS DIELEN MENU MAX ENTER EXIT MAX ENTER MENU

Instruction Manual. mass flow meter for compressed air. Druckluftbilanzierungssystem VARIOMASS VARIOMASS DIELEN MENU MAX ENTER EXIT MAX ENTER MENU Instruction Manual mass flow meter for compressed air Druckluftbilanzierungssystem VARIOMASS VARIOMASS DIELEN K1 K2 1 2 3 MENU 4 5 6 MAX 7 8 9 i 0. EXIT ENTER VARIOMASS DIELEN K1 K2 1 2 3 4 5 6 MAX ENTER

More information

Digital conductivity transmitter

Digital conductivity transmitter Digital conductivity transmitter Compact version with integrated conductivity electrodes Remote version with seperated transmitter for short (15 ft.) or long (1500 ft.) distance Commissioning is easy due

More information

TMU. Coriolis Mass Flow Meter. for liquids and gas

TMU. Coriolis Mass Flow Meter. for liquids and gas Coriolis Mass Flow Meter for liquids and gas measuring monitoring analysing TMU S5 OO Measuring range: 0-60 kg/h 0-2200 t/h water OO Accuracy: ± 0.1% of reading ±zero point stability (from liquids up to

More information

SITRANS F flowmeters SITRANS F M. Transmitter Transmag 2 with sensor 911/E 4/77. Overview

SITRANS F flowmeters SITRANS F M. Transmitter Transmag 2 with sensor 911/E 4/77. Overview Overview Design The complete flowmeter consists of a flow sensor and an associated transmitter from the Transmag 2 for pulsed alternating field. These are available as remote and compact versions ( 911/E

More information

RCM DIRECT READING FLOWMETER

RCM DIRECT READING FLOWMETER RCM DIRECT READING FLOWMETER Flow Pressure Level Temperature measurement monitoring control Special Features Compact Design Easy to Install For Horizontal or Vertical Pipes Rugged Construction Accuracy:

More information

The transducer component converts the measured signal and displays the actual value.

The transducer component converts the measured signal and displays the actual value. Digital inductive conductivity transmitter System Integration Provides low Total Cost of Ownership PEEK/PPA version for CIP applications TEACH IN and SIMULATION Function Approval PVDF Version PEEK Version

More information

S103C ELECTROMAGNETIC FLOW METERS. Main application fields MOUNTING

S103C ELECTROMAGNETIC FLOW METERS. Main application fields MOUNTING ELECTROMAGNETIC FLOW METERS The electromagnetic flow meter is used to measure the flow rate of conductive fluids and waste water. The measurement is independent of the density, viscosity, temperature and

More information

Model Sono-Trak Transit Time

Model Sono-Trak Transit Time Model Sono-Trak Transit Time Ultrasonic Flow Meter Engineered for performance excellence, the Sono-Trak Transit Time ultrasonic meter combines non-invasive, bi-directional measurement with advanced ultrasonic

More information

Digital flow transmitter for continuous flow measurement

Digital flow transmitter for continuous flow measurement Digital flow transmitter for continuous flow measurement Compact or remote version for DN 06 to 400, PN10 Shows both flow rate and volume (with two totalizers) Automatic-calibration: TEACH-IN Simulation:

More information

Digital inductive conductivity transmitter

Digital inductive conductivity transmitter Digital inductive conductivity transmitter Optimal solution for conductivity measurements in difficult fluids (polluted, dirty,...) PEEK/PPA version for CIP applications Large range of process connections

More information

RHE11. Hazardous Area Multifunction Coriolis Flow Transmitter. Features. Applications. Benefits

RHE11. Hazardous Area Multifunction Coriolis Flow Transmitter. Features. Applications. Benefits RHE11 Hazardous Area Multifunction Coriolis Flow Transmitter Features Wall or Pipe Bracket Mount Built in safety barriers allow operation with RHM sensor in hazardous area Selectable Metric and English

More information

SITRANS F flowmeters SITRANS F US. Transmitter FUS060. Overview

SITRANS F flowmeters SITRANS F US. Transmitter FUS060. Overview Overview Function Displays and keypad Operation of the SITRANS FUS060 transmitter can be carried out using: Keypad and display unit HART communicator PC/laptop and SIMATIC PDM software via HART communication

More information

Digital flowmeter for continuous flow measurement

Digital flowmeter for continuous flow measurement 8025 Flowmeter INSERTION Digital flowmeter for continuous flow measurement Compact or remote version for DN06 to DN400, PN10 Displays both flow rate and volume (with two totalizers) On site calibration

More information

INSERTION paddle wheel flowmeter for continuous flow measurement

INSERTION paddle wheel flowmeter for continuous flow measurement INSERTION paddle wheel flowmeter for continuous flow measurement Economic integration in pipe systems without any additional piping 3-wire frequency pulse version to directly interface with PLC s (both

More information

Valve Island with Electronic I/O

Valve Island with Electronic I/O Screw in Temperature /Switch with display for ON/OFF Control Indication, monitoring, transmission and ON/OFF control in one device Extra large display Menu guided parametrisation Complete communication

More information

Digital flow ELEMENT transmitter for continuous flow measurement

Digital flow ELEMENT transmitter for continuous flow measurement ELEMENT Transmitter Digital flow ELEMENT transmitter for continuous flow measurement Type can be combined with... PN10, DN15 to DN400 fluidic process connection Programmable outputs : one or two transistor

More information

INLINE flowmeter for continuous flow measurement

INLINE flowmeter for continuous flow measurement INLINE flowmeter for continuous flow measurement Economic integration in pipe systems without any additional piping 3-wire frequency pulse version to directly interface with PLC s (both PNP and NPN) Connection

More information

INLINE flowmeter for continuous flow measurement

INLINE flowmeter for continuous flow measurement INLINE flowmeter for continuous flow measurement Economic integration in pipe systems without any additional piping 3-wire frequency pulse version to directly interface with PLC s (both PNP and NPN) Connection

More information

ULTRASONlC FlOWMETER SAMPLE BOOK. TYPE:LRF-3300S Concentrating on Flow Measurement

ULTRASONlC FlOWMETER SAMPLE BOOK. TYPE:LRF-3300S Concentrating on Flow Measurement ULTRASONlC FlOWMETER SAMPLE BOOK TYPE:LRF-3300S Concentrating on Flow Measurement Introduction LRF-3300S is a wall-mount, clamp- on type ultrasonic flowmeter which use the transfer time technology. Clamp

More information

Digital flowmeter for continuous flow measurement

Digital flowmeter for continuous flow measurement 8025 Flowmeter INSERTION Digital flowmeter for continuous flow measurement Compact or remote version for DN06 to DN400, PN10 Displays both flow rate and volume (with two totalizers) On site calibration

More information

Using the AcuDew Moisture Transmitter

Using the AcuDew Moisture Transmitter APPLICATION NOTE 2018_5-1 AcuDew Using the AcuDew Moisture Transmitter The AcuDew Transmitter is a two wire, 4-20 ma loop powered transmitter for continuous moisture measurement in process gases, glove

More information

Type PLC Fitting. Valve for Continuous control. Diaphragm valve. Output

Type PLC Fitting. Valve for Continuous control. Diaphragm valve. Output Digital Inductive conductivity transmitter Optimal solution for conductivity measurements in difficult fluids (polluted, dirty,...) PEEK/PPA version for CIP applications Large range of process connections

More information

INLINE flowmeter for continuous flow measurement

INLINE flowmeter for continuous flow measurement INLINE flowmeter for continuous flow measurement Economic integration in pipe systems without any additional piping 3-wire frequency pulse version to directly interface with PLC s (both PNP and NPN) Connection

More information

SHARKY 775 ULTRASONIC COMPACT METER. 4 Approved according EN 1434 and MID in class 2 with dynamic range of 1:250 (qi:qp) in class 2

SHARKY 775 ULTRASONIC COMPACT METER. 4 Approved according EN 1434 and MID in class 2 with dynamic range of 1:250 (qi:qp) in class 2 APPLICATION ultrasonic compact energy meter can be used for measuring the energy consumption in heating / cooling application for billing purposes. The measurement principle is static and based on the

More information

Accuracy: ± 0.1 % of reading ±zero point stability (from liquids up to TMU-x040) Material: (316 L) / (316 Ti)/ Hastelloy C-22

Accuracy: ± 0.1 % of reading ±zero point stability (from liquids up to TMU-x040) Material: (316 L) / (316 Ti)/ Hastelloy C-22 Coriolis Massflowmeter for liquids and gas measuring monitoring analysing TMU S5 Measuring range: 0-60 kg/h 0-2200 t/h water Accuracy: ± 0.1 % of reading ±zero point stability (from liquids up to TMU-x040)

More information

FLOW RATE CORRECTION CALCULATOR GDR 1403

FLOW RATE CORRECTION CALCULATOR GDR 1403 FLOW RATE CORRECTION CALCULATOR GDR 1403 with Ethernet TCP/IP, Profibus-DP, MODBUS-RTU, MODBUS-TCP The correction calculator GDR 1403 measures volume or mass flow of flow rate sensors. Within volume flow

More information

PhD Inline Vortex. Performance Specifications Accuracy. Operating Specifications

PhD Inline Vortex. Performance Specifications Accuracy. Operating Specifications Description The Vortex PhD vortex shedding flowmeter measures process fluid flow by detecting the frequency at which vortices are shed from an obstruction in the process fluid line (the bluff body). A

More information

SonoMeter 31 Energy Meters

SonoMeter 31 Energy Meters SonoMeter 31 Energy Meters Description MID examination certificate no.: LT-1621-MI004-023 The Danfoss SonoMeter 31 is a range of ultrasonic, compact energy meters intended for measuring energy consumption

More information

FLOW RATE CORRECTION CALCULATOR GDR 1403

FLOW RATE CORRECTION CALCULATOR GDR 1403 FLOW RATE CORRECTION CALCULATOR GDR 1403 with Ethernet/IP, Bluetooth, Profibus DP, MODBUS-RTU, MODBUS-TCP The correction calculator GDR 1403 measures volume or mass flow of flow rate sensors. Within volume

More information

RHE12. Hazardous Area Coriolis Mass Flow Transmitter. Features. Applications. Benefits

RHE12. Hazardous Area Coriolis Mass Flow Transmitter. Features. Applications. Benefits RHE12 Hazardous Area Coriolis Mass Flow Transmitter Features Field mounting Compact, pressure safe housing ATEX and CSA approvals for installation in hazardous areas 24 VDC power supply Configurable analog

More information

Coriolis Massflowmeter

Coriolis Massflowmeter Coriolis Massflowmeter for liquids and gas measuring monitoring analysing Measuring range: 0-60 kg/h 0-60 000 kg/h water Accuracy: ±0,15 of reading ±zero-point stability pmax: PN40 tmax: -40 +180 C Connection:

More information

SHARKY 775 ULTRASONIC COMPACT METER. 4 Approved according EN 1434 and MID in class 2 with dynamic range of 1:250 (qi:qp) in class 2

SHARKY 775 ULTRASONIC COMPACT METER. 4 Approved according EN 1434 and MID in class 2 with dynamic range of 1:250 (qi:qp) in class 2 APPLICATION ultrasonic compact energy meter can be used for measuring the energy consumption in heating / cooling application for billing purposes. The measurement principle is static and based on the

More information

Digital flow ELEMENT transmitter for continuous flow measurement

Digital flow ELEMENT transmitter for continuous flow measurement Digital flow ELEMENT transmitter for continuous flow measurement Type 8036 can be combined with... DN06 to DN65 fluidic process connection Programmable outputs : one or two transistor output(s) and single

More information

Coriolis Massflowmeter

Coriolis Massflowmeter Coriolis Massflowmeter for liquids and gas measuring monitoring analysing Measuring range: 0-0.8 kg / h 0-65 000 kg / h water Accuracy: ± 0.1 of reading ±zero-point stability (liquids) pmax: PN40 tmax:

More information

SCHMIDT Flow Sensor SS SS FB

SCHMIDT Flow Sensor SS SS FB Product description Flow sensor with integrated microcontroller transducer for the measurement of air-flow velocity and for the determination of the flow rate and flow volume. The aerodynamically styled

More information

Infocal 9 Energy calculator

Infocal 9 Energy calculator Infocal 9 Energy calculator Description/Application MID examination certificate no.: LT-1621-MI004-028 The INFOCAL 9 is an energy calculator, e.g. for combination with or SonoSensor 30. It is especially

More information

Flow Switch - 2 programmable thresholds. Stand Alone (Battery) - Battery powered, - 2 totalizers display, - Local flow display,

Flow Switch - 2 programmable thresholds. Stand Alone (Battery) - Battery powered, - 2 totalizers display, - Local flow display, DN 15 - DN 50; PN Advantages / Benefits Easy System integration by Easy LINK provides low cost of ownership Easy commissioning due to multi-language, menu-guided operation TEACH-IN: automatic calibration

More information

SHARKY 775 ULTRASONIC COMPACT METER. 4 Approval with dynamic range up to 1:250 (qi:qp) MID in class 2 (depends on meter size), standard 1:100

SHARKY 775 ULTRASONIC COMPACT METER. 4 Approval with dynamic range up to 1:250 (qi:qp) MID in class 2 (depends on meter size), standard 1:100 APPLICATION ultrasonic compact energy meter can be used for measuring the energy consumption in heating / cooling application for billing purposes. The measurement principle is static and based on the

More information

Electromagnetic Flow Transmitter

Electromagnetic Flow Transmitter Electromagnetic Flow Transmitter Sensor in solid state technology Working as a transmitter and/or as an On/Off controller Automatic-calibration of full scale: Teach-In Clean in place (CIP) Type can be

More information

MHPS MHPS. Modular pressure transmitter. Technical documentation. Table of content. Characteristics - applications - technical data

MHPS MHPS. Modular pressure transmitter. Technical documentation. Table of content. Characteristics - applications - technical data Technical documentation Table of content Page 2: Page 3: Page 4: Page 5: Page 6: Page 7: Page 8: Characteristics - applications - technical data Technical data - input quantity - output quantity Electrical

More information

THM80X Series Industry degree high accuracy Temp. & humidity transmitter

THM80X Series Industry degree high accuracy Temp. & humidity transmitter THM80X Series Industry degree high accuracy Temp. & humidity transmitter Introduction IP65 protection degree, rugged aluminum case, fit in variety harsh environment Capable of temperature compensation

More information

Digital batch controller

Digital batch controller INSERTION Digital batch controller Type 8025 can be combined with... Compact or remote version for DN06 to DN400, PN10 Dosing On site calibration by Teach-In Check of input/output signals Total and daily

More information

Ambient Conditions. Operating Conditions. Pressure

Ambient Conditions. Operating Conditions. Pressure Temperature Relative Humidity -20 C +75 C 0% 100 RH to 65 C non condensing 86 106 bar 4.0MPa (DN10 DN80) 1.6MPa (DN100 DN150) 1.0MPa (DN200 DN1000) Remote version < 80 C (rubber coating) Compact version

More information

SolidFlow 2.0. Solid mass flow measurement. Product Information. SWR engineering Messtechnik GmbH enveatm a trademark of Environnement S.

SolidFlow 2.0. Solid mass flow measurement. Product Information. SWR engineering Messtechnik GmbH enveatm a trademark of Environnement S. EN SolidFlow.0 Product Information Solid mass flow measurement SWR engineering Messtechnik GmbH enveatm a trademark of Environnement S.A Group Use SolidFlow.0 has been specially developed for measuring

More information

Ultrasonic level transmitter, non-contact

Ultrasonic level transmitter, non-contact Ultrasonic level transmitter, non-contact Type 8175 can be combined with... Compact, remote versions for level measurement up to 10 m Multi language menu control Interference echo filter Automatic calibration:

More information

MJK Expert 700 / 800 / 900 / 1100 / 2100 MJK Expert 1400 / 3400

MJK Expert 700 / 800 / 900 / 1100 / 2100 MJK Expert 1400 / 3400 Data Sheet MJK Expert 700 / 800 / 900 / 1100 / 2100 MJK Expert 1400 / 3400 Submersible Hydrostatic s Rugged and versatile We reserve the right to continuously improve our products and make any change in

More information

Magnetic-inductive flow meter. PITe / UMF2. Technical Datasheet. Maintenance-free Nearly no pressure drop Robust design Easy installation and start-up

Magnetic-inductive flow meter. PITe / UMF2. Technical Datasheet. Maintenance-free Nearly no pressure drop Robust design Easy installation and start-up Magnetic-inductive flow meter Technical Datasheet PITe / UMF2 Maintenance-free Nearly no pressure drop Robust design Easy installation and start-up Subject to change without notice 1 Function An electrically

More information

PAD - Heavy Duty Differential Pressure Trasmitter

PAD - Heavy Duty Differential Pressure Trasmitter Benefits and Features Span: 0.3" W.C. 6" W.C. to 60 6000 PSIG Static Pressure: Max. 4500 PSIG t max : 248 F Process Connection: ½" NPT, ¼" NPT, or Various Diaphragm Seals Available upon Request Material:

More information

Non-Submersible Industrial Pressure Transducer

Non-Submersible Industrial Pressure Transducer Non-Submersible Industrial Pressure Transducer KPSI Transducers Series 27, 28, 30 FEATURES Custom Pressure Ranges up to 2000 (13,790 kpa) Accuracy to ±0.10% FS Analog Outputs of 4-20 ma or VDC Welded 316

More information

The SFC 1000PA P2DAAA can be mounted on a prover trailer, which can be moved from field to field to provide proving services.

The SFC 1000PA P2DAAA can be mounted on a prover trailer, which can be moved from field to field to provide proving services. The SFC 1000 P2DAAA is a dual meter run bidirectional flow computer with a built in Rosemount 205 Multivariable Transmitter (DP, P, and TEMP) for the measurement of liquid & Gas products. Using orifice

More information

4-20mA, 0-10V and general process measuring bargraph displays

4-20mA, 0-10V and general process measuring bargraph displays Page 1 of 6 Digital panel meters Large displays Bargraphs Transmitters 4-20mA, 0-10V process input bargraph displays Display almost any physical variable... The bargraph displays on this page accept most

More information

HD48V01T HD48V17T HD48V77T. [ GB ] Temperature, Relative humidity and Dew Point transmitters

HD48V01T HD48V17T HD48V77T. [ GB ] Temperature, Relative humidity and Dew Point transmitters H4801T H48V01T H4817T H48V17T H4877T H48V77T [ GB ] Temperature, Relative humidity and ew Point transmitters [ GB ] [ GB ] escription H48.. series of transmitters measure temperature, relative humidity

More information

ph or ORP Transmitter

ph or ORP Transmitter ph or ORP Transmitter Programmable outputs: two transistor and single or dual analog 4-20 ma (Process + Temp) Removable backlighted display Universal process connection Compatible with 120 mm ph/ ORP probes

More information

Electronically controlled proportional pressure regulating valves

Electronically controlled proportional pressure regulating valves Overview Description airfit control Electronically valve G1/4, G3/8, Type SRE-.. airfit control Electronically valve G3/8, G1/2, Type CRE-.. airfit control Electronically valve G3/4, G1, Type A25RE-..

More information

ULTRASONIC FLOW METER FT101

ULTRASONIC FLOW METER FT101 Introduction F t101 is a wall-mount, clamp- on type ultrasonic flowmeter which use the transfer time technology. Clamp on type ultrasonic flowmeter is easy to install and no need to cut off the pipe, that

More information

SONOMETER TM 1100 Ultrasonic compact energy meter

SONOMETER TM 1100 Ultrasonic compact energy meter Data sheet SONOMETER TM 1100 Ultrasonic compact energy meter Description/Application MID examination certificate no. : DE-10-MI004-PTB003 The SONOMETER 1100 is an ultrasonic static compact energy meter

More information

TEK-F LEX 4100A. Guided Wave Radar Level Transmitter. LEVEL. Technology Solutions

TEK-F LEX 4100A. Guided Wave Radar Level Transmitter.   LEVEL. Technology Solutions Technology Solutions TEK-F LEX 4100A Guided Wave Radar Level Transmitter LEVEL www.tek-trol.com Flow Level Temperature Pressure Valves Analyzers Accessories TekValSys Introduction Featuring TDR (Time Domain

More information

} Max. Load Resistance : 750Ω when power supply voltage is 24V DC (Max. load resistance (Ω) = 50x Power Supply Voltage -450 ).

} Max. Load Resistance : 750Ω when power supply voltage is 24V DC (Max. load resistance (Ω) = 50x Power Supply Voltage -450 ). ISO-14001 ISO-9001 SPECIFICATION SHEET CP SERIES 2-WIRE TYPE DO TRANSMITTER Models: DCP-20T FEATURES Rigid aluminium enclosure with free angle mounting. Simple operation offers free range setting, auto-calibration,

More information

NUS-4. Ultrasonic Level Transmitter. for Liquids and Solids

NUS-4. Ultrasonic Level Transmitter. for Liquids and Solids Ultrasonic Level Transmitter for Liquids and Solids measuring monitoring analyzing 4 Measuring Ranges: Liquids: Up to 25 meters (80 feet) Solids: Up to 10 meters (32 feet) Accuracy: ± 0.2 % of Reading

More information

TEK-TEMP 2100A. Explosion-Proof Temperature Transmitter. TEMPERATURE. Technology Solutions

TEK-TEMP 2100A. Explosion-Proof Temperature Transmitter.   TEMPERATURE. Technology Solutions Technology Solutions TEK-TEMP 2100A Explosion-Proof Temperature Transmitter TEMPERATURE www.tek-trol.com Flow Level Temperature Pressure Valves Analyzers Accessories TekValSys Introduction Tek-Trol s Explosion-Proof

More information

Coriolis Mass Flow Meter Model TM

Coriolis Mass Flow Meter Model TM Coriolis Mass Flow Meter for liquids and gas measuring monitoring analysing TM S5 Measuring range: 0-0.8 kg / h 0-65000 kg / h water Accuracy: ± 0.1 of reading ± zero-point stability (liquids) p max :

More information

INTRODUCING SOME GREAT NEW PRODUCTS FROM OUR DWYER INSTRUMENTS RANGE:

INTRODUCING SOME GREAT NEW PRODUCTS FROM OUR DWYER INSTRUMENTS RANGE: Unit 1 / 14 Biscayne Way Jandakot WA 6104 P.O. Box 3232, Success WA 6964 Tel: (08) 9414 7666 Fax: (08) 9414 7677 Email: dg@dginstruments.com.au Website: www.dginstruments.com.au A.B.N: 59 113 005 959 DATE:

More information

SITRANS F flowmeters SITRANS F US. Transmitter FUS080. 4/194 Siemens FI

SITRANS F flowmeters SITRANS F US. Transmitter FUS080. 4/194 Siemens FI Overview The transmitter is available in an IP67/NEMA X/6 enclosure and is designed for use in the flowmeters series: SONOKIT (1- or 2-track) FUS380 (2-track) FUE380 (2-track) The transmitter FUS080 is

More information

S T T U S I N S T R U M E N T S

S T T U S I N S T R U M E N T S S T T U S I N S T R U M E N T S Welcome to the latest Status Instruments Product Guide Here at Status Instruments, we re very proud to say that we ve been making top-quality instrumentation for 30 years.

More information

FLOMID FX Electromagnetic Flowmeter

FLOMID FX Electromagnetic Flowmeter FLOMID FX Electromagnetic Flowmeter Working pressure manufacturing according to PED 97/23/CE (Lloyd s Register Certificate Nº 031) Introduction Modular design in two versions: Compact, sensor and electronics

More information

P R o D u c T I n F o R m at I o n. TDR Level Sensor LFP. The clean solution

P R o D u c T I n F o R m at I o n. TDR Level Sensor LFP. The clean solution P R o D u c T I n F o R m at I o n TDR Level Sensor The clean solution Level sensors The clean solution Product description The is a hygienic level sensor for liquids using TDR technology a process for

More information

Precision Thermistor Sensors

Precision Thermistor Sensors Precision Thermistor Sensors For Laboratory Applications ON-400 Series U For Use in Laboratory or Other High-Accuracy Applications U Rugged Construction Can Be Used for Short Term Water and Soil Readings

More information

Condumax W CLS19. Technical Information. Conductivity sensors Two-electrode sensors with cell constants k = 0.01 cm 1 or k = 0.

Condumax W CLS19. Technical Information. Conductivity sensors Two-electrode sensors with cell constants k = 0.01 cm 1 or k = 0. Technical Information Condumax W CLS9 Conductivity sensors Two-electrode sensors with cell constants k = 0.0 cm or k = 0. cm Application Measurement in pure and ultrapure water: Monitoring ion exchangers

More information

INFOCAL 8 Energy calculator

INFOCAL 8 Energy calculator Data sheet INFOCAL 8 Energy calculator Description/Application MID examination certificate no.: DE-10-MI004-PTB008 The INFOCAL 8 is an energy calculator e.g. for combination with SONO 1500 CT especially

More information

B850 Boiler House Energy Monitor

B850 Boiler House Energy Monitor Local regulations may restrict the use of this product to below the conditions quoted. In the interests of development and improvement of the product, we reserve the right to change the specification without

More information

SM-15. Features. Plastic Flowmeters as per the Variable Area Principle. Description: Application:

SM-15. Features. Plastic Flowmeters as per the Variable Area Principle. Description: Application: / Flow / Variable Area SM-5 Plastic Flowmeters as per the Variable Area Principle Description: Features / For every industrial application / For fluid and gaseous media / Simple and robust design with

More information

RTD Temperature Sensor omnigrad T -TSM 480, TR 480. Hygienic RTD sensor with Pt 100, class A TSM 480 with electronics programmable via PC

RTD Temperature Sensor omnigrad T -TSM 480, TR 480. Hygienic RTD sensor with Pt 100, class A TSM 480 with electronics programmable via PC Technical Information TI 273T/02/en 60021667 RTD Temperature Sensor omnigrad T -TSM 480, TR 480 Hygienic RTD sensor with Pt 100, class A TSM 480 with electronics programmable via PC Application The Omingrad

More information

4.00 ULTRASONIC ANALYZER

4.00 ULTRASONIC ANALYZER U.S. PRICE LIST PAGE 1 OF 14 ULTRASONIC IN-LINE ANALYZER FOR LIQUIDS EVALUATION UNIT (1) BINARY LIQUIDS 8100-1/2-19" Rhosonics Model 8100 (19" rack - basic analyzer - 1 x sensor input) $9,875.00 8100-BENCHTOP

More information

SONOMETER TM 1100 Ultrasonic compact energy meter

SONOMETER TM 1100 Ultrasonic compact energy meter Data sheet SONOMETER TM 1100 Ultrasonic compact energy meter Description/Application MID examination certificate no. : DE-10-MI004-PTB003 The SONOMETER 1100 is an ultrasonic static compact energy meter

More information

Advanced instrumentation solutions crafted with highest precision

Advanced instrumentation solutions crafted with highest precision www.adeptfluidyne.com Advanced instrumentation solutions crafted with highest precision Working Principle The Transit Time Flowmeter utilises two transducers that function as both ultrasonic transmitters

More information

Brunata Optuna H. Properties. Counter

Brunata Optuna H. Properties. Counter Brunata Optuna H Brunata Optuna H measures energy consumption in large and small heating and cooling systems as well as combined heating and cooling systems. The meter is compact and belongs to the first

More information

DN 16 ISO-KF. Dimensional drawings THERMOVAC TM 101 (mm)

DN 16 ISO-KF. Dimensional drawings THERMOVAC TM 101 (mm) Products Handheld Measuring Instruments Digital PIEZOVAC Sensor PV 101 Digital THERMOVAC Sensor TM 101 The digital compact PIEZOVAC PV 101 and THERMOVAC TM 101 combine high-quality sensor technology with

More information

SITRANS F flowmeters SITRANS F US. SONOFLO SONO 3000 transmitter. 4/152 Siemens FI Overview

SITRANS F flowmeters SITRANS F US. SONOFLO SONO 3000 transmitter. 4/152 Siemens FI Overview Overview Design The transmitter is available in different enclosure to fit any demands: IP67 enclosure for compact or wall mounting IP00 as a 19 insert IP65 for wall mounting IP65 enclosure in stainless

More information

UTM10 Series Ultrasonic Transit-time Flowmeters

UTM10 Series Ultrasonic Transit-time Flowmeters Ultrasonic Transit-time meters Description UTM10 ultrasonic flow and energy meters clamp onto the outside of pipes and do not make contact with the internal liquid. The technology has inherent advantages

More information

WATERFLUX 3000 Quick Start

WATERFLUX 3000 Quick Start WATERFLUX 3000 Quick Start Electromagnetic flow sensor The documentation is only complete when used in combination with the relevant documentation for the signal converter. KROHNE CONTENTS WATERFLUX 3000

More information

OPTIFLUX 5000 Technical Datasheet

OPTIFLUX 5000 Technical Datasheet OPTIFLUX 5000 Technical Datasheet Electromagnetic flowmeter in flanged version Exceptional long-term stability and accuracy For highly aggressive and abrasive fluids Fully vacuum-resistant with high-tech

More information

JUMO Wtrans E01. Measuring probe for humidity, temperature, and CO 2 with wireless data transmission. Brief description. Universal Wtrans receiver

JUMO Wtrans E01. Measuring probe for humidity, temperature, and CO 2 with wireless data transmission. Brief description. Universal Wtrans receiver Page 1/13 JUMO Wtrans E01 Measuring probe for humidity, temperature, and CO 2 with wireless data transmission Humidity from 0 to 100 % RH (incl. -40 to +80 C) or CO 2 from 0 to 2000/5000/10000 ppm or Temperature

More information

BGN. All Metal Variable Area Flowmeter and Counter. for liquids and gases

BGN. All Metal Variable Area Flowmeter and Counter. for liquids and gases All Metal Variable Area Flowmeter and Counter for liquids and gases monitoring analysing BGN Measuring range: 0.5-5.0... 13000-130000 l/h water 0.015-0.15... 240-2400 m³/h air (20 C, 1.013 bar) Accuracy

More information

J Series induq VMZ MAGNETIC INDUCTIVE FLOW SENSORS. DB_Magnetic_Inductive_Flow_Sensors 05/2016

J Series induq VMZ MAGNETIC INDUCTIVE FLOW SENSORS. DB_Magnetic_Inductive_Flow_Sensors 05/2016 J Series induq VMM J Series induq VMI J Series induq VMZ MAGNETIC INDUCTIVE FLOW SENSORS J DB_Magnetic_Inductive_Flow_Sensors 5/216 67 Magnetic inductive flow sensors Principle of operation The smart flow

More information

DA 30 High Torque Technical Specification

DA 30 High Torque Technical Specification 1/17 DA 30 High Torque DA 30-HT-30-5848 2/17 Content 1. General Description... 3 2. Operating Data... 4 3. Performance... 5 4. Materials and Protective Features... 6 5. Dimensions... 6 5.1. Installation

More information

Flow Measurement SITRANS F M

Flow Measurement SITRANS F M Overview Mode of operation The flow measuring principle is based on Faraday s law of electromagnetic induction according to which the sensor converts the flow into an electrical voltage proportional to

More information

Rosemount Specifications. Product Data Sheet , Rev BA February 2009 PERFORMANCE SPECIFICATIONS

Rosemount Specifications. Product Data Sheet , Rev BA February 2009 PERFORMANCE SPECIFICATIONS Rosemount 2051 Product Data Sheet PERFORMANCE SPECIFICATIONS Specifications For zero based spans, reference conditions, silicone oil fill, SST materials, Coplanar flange () or 1 /2 in. - 14 NPT () process

More information

C4000. inline control. Photometric Converter. Real-time photometric converter. Factory zero for scattered light sensors

C4000. inline control. Photometric Converter.  Real-time photometric converter. Factory zero for scattered light sensors C4000 Photometric Converter inline control Real-time photometric converter Factory zero for scattered light sensors Simultaneous operation of up to four inline sensors Process control functions via Remote

More information

www. otech.com.sg EFS801 ELECTROMAGNETIC FLOWMETER

www. otech.com.sg EFS801 ELECTROMAGNETIC FLOWMETER www. otech.com.sg EFS801 ELECTROMAGNETIC FLOWMETER 1 www. otech.com.sg EFS801 - CFT181/RFT201 ELECTROMAGNETIC FLOWMETER Accurate, Reliable and Stable Flow Measurement. Measuring Principle The measuring

More information

GS.No.GBN062E-5. GENERAL SPECIFICATIONS Sensor unit

GS.No.GBN062E-5. GENERAL SPECIFICATIONS Sensor unit High performance microflow Coriolis Flowmeter GENERAL SPECIFICATION GS.No. GENERAL Based on the Coriolis technologies accumulated over many years, the OVAL has broadened its current general purpose coriolis

More information

Temperature Sensor. Temperature Transmitter MPU-LCD with Display Product Information TSM and TSB FOOD SENSORS FOR FOOD AND LIFE SCIENCES.

Temperature Sensor. Temperature Transmitter MPU-LCD with Display Product Information TSM and TSB FOOD SENSORS FOR FOOD AND LIFE SCIENCES. SENSORS FOR FOOD AND LIFE SCIENCES. Product Information TSM and TSB FOOD Temperature Sensor Application/Specified usage Temperature Measurement in vessels and pipes Authorizations Application examples

More information

prosonic T FMU230, FMU231

prosonic T FMU230, FMU231 Technical Information prosonic T FMU230, FMU231 Ultrasonic Level Measurement Compact transmitters for non-contact level measurement of fluids and coarse bulk materials Application The compact transmitters

More information

Rosemount 848L Logic Transmitter with FOUNDATION Fieldbus

Rosemount 848L Logic Transmitter with FOUNDATION Fieldbus Logic Transmitter with FOUNDATION Fieldbus Integrates Discrete I/O on a FOUNDATION Fieldbus H1 Segment Reduces Installation and Maintenance Costs with a Single Network for Analog and Discrete devices Easily

More information

Measurement. SITRANS F US Inline. 3/262 Siemens FI Transmitter SITRANS FUS080/FUE080

Measurement. SITRANS F US Inline. 3/262 Siemens FI Transmitter SITRANS FUS080/FUE080 Overview The transmitter is available in an IP67/NEMA 4X/6 enclosure and is designed for use in the flowmeters series: SONOKIT (1-path or -path) FUS80 (-path) FUE80 (-path) The transmitter FUS080 is always

More information

Measuring range: l/h water m³/h air (20 C, bar) Connection: Flange DN 15...

Measuring range: l/h water m³/h air (20 C, bar) Connection: Flange DN 15... Full Metal Variable Area Flow Meter and Counter for Liquids and Gases monitoring analysing BGN Special versions up to 600 bar O Nominal diameter up to DN 150 S2 Measuring range: 0.5-5.0... 13000-130000

More information

Advanced instrumentation solutions crafted with highest precision

Advanced instrumentation solutions crafted with highest precision www.adeptfluidyne.com Advanced instrumentation solutions crafted with highest precision perpendicular to both the liquid flow direction and the electromagnetic field direction. The voltage sensed by the

More information

Flow Meter FC100. Description FC100. Ordering information

Flow Meter FC100. Description FC100. Ordering information Flow Meter FC00 Microcontroller operated Flow Meter to monitor and display flow rates and temperature. Once correctly adjusted it can also be used for mass flow measurements. Factory preset for air and

More information

EN-2018 MAGNETIC FLOW METERS

EN-2018 MAGNETIC FLOW METERS EN-2018 MAGNETIC FLOW METERS www.meatest.com 1 MEASURING PRINCIPLE Having no moving or mechanical parts in the flow profile electromagnetic flow meters cause no pressure drop, are virtually maintenance

More information

Electro-Magnetic Flowmeters COPA-XE

Electro-Magnetic Flowmeters COPA-XE Data Sheet Electro-Magnetic Flowmeters COPA-XE 10DX4311 Flowmeter system utilizes a smart microprocessor converter System accuracy of ± 0.5% of rate Field configurable via integral pushbuttons, eliminates

More information

Conductivity measurement SmarTec S CLD 132

Conductivity measurement SmarTec S CLD 132 Technical Information TI 207C/24/ae Conductivity measurement SmarTec S CLD 132 Transmitter for measurement of conductivity and concentration with inductive sensor Areas of application Alkali/acid concentration

More information