Product Information. Universal gripper JGZ

Size: px
Start display at page:

Download "Product Information. Universal gripper JGZ"

Transcription

1 Product Informaton Unversal grpper JGZ

2 JGZ Unversal grpper Loadable. Relable. Compact. JGZ unversal grpper Unversal 3-fnger centrc grpper of the compact class wth T-slot gudance and best cost-performance rato Feld of applcaton Optmum standard soluton for many felds of applcaton. Unversal applcaton n clean and slghtly drty surroundngs n machne buldng and plant buldng ndustry, assembly and handlng as well as automotve ndustry. Advantages Your benefts A frm focus on the essentals for maxmum proftablty Sturdy T-slot gudance for the precse handlng of dfferent workpeces Compact dmensons and low weght for mnmal nterferng contours n handlng Hgh maxmum moments possble sutable for usng long grpper fngers Wedge-hook desgn for hgh power transmsson and synchronzed grppng Comprehensve sensor accessores for montorng and control of the stroke poston Fastenng at one grpper sde n two screw drectons for unversal and flexble grpper assembly Ar supply va hose-free drect connecton or screw connectons for flexble pressure supply n all automated systems Szes Quantty: 7 Weght kg Grppng force N Stroke per jaw mm Workpece weght kg 2

3 JGZ Unversal grpper Functonal descrpton The pston s moved up and down by compressed ar. The angled actve surfaces of the wedge-hook produce a synchronzed, centrc jaw movement. JGZ 1 Housng Weght-optmzed due to the use of hgh-strength alumnum alloy 2 T-slot gudance loadable, robust base jaw gudance for extremely long grpper fngers 3 Wedge-hook desgn for hgh force transmsson and centrc grppng 4 Base Jaw for the connecton of workpece-specfc grpper fngers 5 Sensor system Proxmty swtch can be assembled wthout mountng kt CAD data, operatng manuals and other current product documents can be found onlne. 3

4 JGZ Unversal grpper General notes about the seres Operatng prncple: Wedge-hook knematcs Housng materal: Alumnum alloy, anodzed Base jaw materal: Steel Actuaton: pneumatc, wth fltered compressed ar as per ISO :2010 [7:4:4]. Warranty: 24 months Scope of delvery: Bracket for proxmty swtch, centerng sleeves, O-rngs for drect connecton, assembly and operatng manual wth Declaraton of Incorporaton. Grppng force mantenance: possble by usng the verson wth mechancal grppng force mantenance or SDV-P pressure mantenance valve Grppng force: s the arthmetc total of the grppng force appled to each grpper jaw at dstance P (see llustraton). Fnger length: s measured from the reference surface as the dstance P n drecton to the man axs.the maxmum permssble fnger length apples untl the nomnal operatng pressure s acheved. Wth hgher pressures, the fnger length must be reduced proportonally to the nomnal operatng pressure. Repeat accuracy: s defned as the spread of the end poston durng 100 consecutve strokes. Workpece weght: s calculated for force-ft grppng wth a coeffcent of statc frcton of 0.1 and a safety factor of 2 aganst workpece slppage at acceleraton due to gravty g. For form-ft or capture grppng, there are sgnfcantly hgher permssble workpece weghts. Closng and openng tmes: are purely the tmes that the base jaws or fngers are n moton. Valve swtchng tmes, hose fllng tmes, or PLC reacton tmes are not a part of ths and are to be consdered when cycle tmes are calculated. Applcaton example Tactle assembly of nserton ads n cylnder heads 1 JGZ 3-fnger centrc grpper wth workpece-specfc grpper fngers 2 FTC axs force-torque sensor 4

5 JGZ Unversal grpper SCHUNK offers more... The followng components make the product JGZ even more productve the sutable addton for the hghest functonalty, flexblty, relablty, and controlled producton. TCU tolerance compensaton unt Compensaton unt Pressure mantenance valve Unversal ntermedate jaw Flexble poston sensor Sensor system Fnger blanks wth quckchange jaw system Jaw quck-change system Force-measurng jaws Analog poston sensor Addtonal nformaton regardng the products can be found on the followng product pages or at Please contact us for further nformaton: SCHUNK techncal hotlne Optons and specal nformaton Grppng force mantenance verson AS / IS: The mechancal grppng force mantenance verson ensures a mnmum grppng force also n the case of a drop n pressure. In the AS / S verson ths has the effect of a closng force, n the IS verson of an openng force The JGZ seres s especally sutable for economc handlng solutons and dstngushes by ts hgh cost-beneft rato. 5

6 JGZ 40 Unversal grpper Grppng force, O.D. grppng Fnger load Grppng force Grppng force, I.D. grppng Pont P - Fnger length M x max. 8 Nm M y max. 10 Nm M z max. 4 Nm F z max. 200 N Grppng force JGZ JGZ 40-1-IS The specfed torques and forces are statc values, apply for each base jaw, and may occur smultaneously. M y may arse n addton to the moment generated by the grppng force tself. 200 F [N] L [mm] Pont P - Fnger length Techncal data Descrpton JGZ 40-1 JGZ 40-1-AS JGZ 40-1-IS ID Stroke per jaw [mm] Closng / openng force [N] 255/ /- -/370 Mn. sprng force [N] Weght [kg] Recommended workpece weght [kg] Flud consumpton double stroke [cm³] Mn./max. operatng pressure [bar] 2/8 4/6.5 4/6.5 Nomnal operatng pressure [bar] Mn./max. ar purge pressure [bar] 0.5/1 0.5/1 0.5/1 Closng/openng tme [s] 0.02/ / /0.02 Closng- / openng tme wth sprng [s] Max. permssble fnger length [mm] Max. permssble mass per fnger [kg] Protecton class IP Mn./max. ambent temperature [ C] 5/90 5/90 5/90 Repeat accuracy [mm] Cleanroom class ISO

7 JGZ 40 Unversal grpper Man vew The drawng shows the grpper n the basc verson wth closed jaws, wthout dmensonal consderaton of the optons descrbed below. The SDV-P pressure mantenance valve can also be used for I.D. or O.D. grppng alternatvely or n addton to the sprng-loaded, mechancal grppng force mantenance devce (see catalog secton on accessores). A, a Man / drect connecton, grpper openng B, b Man / drect connecton, grpper closng S Ar purge connecton 1 Grpper connecton 2 Fnger connecton BN Bolt crcle GL Ft for centerng sleeves GM Ft for centerng pns HT Depth of the centerng sleeve hole n the counter part IT Thread below the cover for fastenng external attachments IK Sensor MMS

8 JGZ 40 Unversal grpper Hose-free drect connecton M3 Grppng force mantenance devce AS / IS 3 Adapter 4 Grppers The drect connecton s used for supplyng compressed ar wthout hoses. Instead, the pressure medum s fed through bore-holes n the mountng plate. The mechancal grppng force mantenance devce ensures that a mnmum clampng force wll be appled even f there s a drop n pressure. Ths acts as closng force n the AS / S verson, and as openng force n the IS verson. Besdes ths, the grppng force mantenance devce can be used to ncrease the grppng force or for sngle actuated grppng. Sprng-loaded pressure pece SDV-P pressure mantenance valve For sprng-supported postonng of the workpece aganst a stop after the grpper has opened. Especally developed for loadng machnes. Descrpton ID Stroke Mn. force [mm] [N] Sprng-loaded pressure pece A-PZN-plus Grppers IT SDV-P pressure mantenance valve The SDV-P pressure mantenance valve ensures n emergency STOP stuatons that the pressure n the pston chamber of pneumatc grpper, swvel, lnear, and quck-change modules s temporarly mantaned. Descrpton ID Pressure mantenance valve SDV-P Pressure mantenance valve wth ar bleed screw SDV-P 04-E

9 JGZ 40 Unversal grpper UZB 40 unversal ntermedate jaw Fnger blanks ABR- / SBR-PGZN-plus 40 1 Grpper connecton 2 Fnger connecton EN Optonal rght or left connecton EQ Lockng GL Ft for centerng sleeves HT Depth of the centerng sleeve hole n the counter part The drawng shows the UZB unversal ntermedate jaw. Descrpton ID Grd dmenson [mm] Unversal ntermedate jaw UZB Fnger blanks ABR-PGZN-plus SBR-PGZN-plus Fnger connecton GL Ft for centerng sleeves The drawng shows the fnger blank whch can be reworked by the customer. Descrpton ID Materal Scope of delvery Fnger blanks ABR-PGZN-plus Alumnum 1 SBR-PGZN-plus MnCr5 1 XY compensaton unt wth sprng return IT Montorng Grppers can be drectly mounted wthout an adapter plate. For detals see our catalog Grppng or Robot Accessores. Descrpton ID Compensaton XY Reset force [mm] [N] Compensaton unt AGE-F-XY ± AGE-F-XY ± Often combned AGE-F-XY ±

10 JGZ 40 Unversal grpper Electronc magnetc swtches MMS AQ Cable outlet IT Sensor MMS 22.. IK Sensor MMS SA End poston montorng for mountng n the C-slot. Descrpton ID Often combned Electronc magnetc swtches MMS MMS 22-S-M8-PNP MMSK 22-S-PNP MMS electronc magnetc swtches wth lateral outlet MMS 22-S-M8-PNP-SA MMSK 22-S-PNP-SA Cable extenson KV BW08-SG08 3P-0030-PNP KV BW08-SG08 3P-0100-PNP KV BW08-SG08 3P-0200-PNP clp for plug/socket CLI-M Connecton cables KA BG08-L 3P-0300-PNP KA BG08-L 3P-0500-PNP KA BW08-L 3P-0300-PNP KA BW08-L 3P-0500-PNP Sensor dstrbutor V2-M V4-M V8-M Two sensors (closer/s) are requred for each unt and extenson cables are avalable as an opton. For sensor cables, note the mnmum permssble bendng rad. These are generally 35 mm. 10

11 JGZ 40 Unversal grpper Programmable magnetc swtch MMS 22-PI1 Programmable magnetc swtch MMS 22-PI2 AQ Cable outlet IT Sensor MMS 22 PI1-... IK Sensor MMS 22..-PI1-...-SA Poston montorng wth one programmable poston per sensor and electroncs ntegrated n the sensor. Can be programmed usng MT magnetc teachng tool (ncluded n scope of delvery) or ST plug teachng tool (optonal). End poston montorng s mounted n the C-slot. If the ST plug teachng tools are lsted n the table provded, teachng s only possble wth the ST teachng tools. Descrpton ID Often combned Plug teachng tool ST-MMS 22-PI1-PNP Programmable magnetc swtch MMS 22-PI1 MMS 22-PI1-S-M8-PNP MMSK 22-PI1-S-PNP Programmable magnetc swtch MMS 22-PI1 wth lateral connecton MMS 22-PI1-S-M8-PNP-SA MMSK 22-PI1-S-PNP-SA Programmable magnetc swtch MMS 22-PI1 wth stanless steel housng MMS 22-PI1-S-M8-PNP-HD MMSK 22-PI1-S-PNP-HD AQ Cable outlet IT MMS PI2-... sensor Poston montorng wth two programmable postons per sensor and electroncs bult nto the sensor. Can be programmed usng MT magnetc teachng tool (ncluded n the scope of delvery) or ST plug teachng tool (optonal). End poston montorng for mountng n the C-slot. If the ST plug teachng tools are lsted n the table provded, teachng s only possble wth the ST teachng tools. Descrpton ID Often combned Plug teachng tool ST-MMS 22-PI2-PNP Programmable magnetc swtch MMS 22-PI2 MMS 22-PI2-S-M8-PNP MMSK 22-PI2-S-PNP Programmable magnetc swtch MMS 22-PI2 wth stanless steel housng MMS 22-PI2-S-M8-PNP-HD MMSK 22-PI2-S-PNP-HD Per unt one sensor (closer/s) s requred, optonally a cable extenson. For sensor cables, note the mnmum permssble bendng rad. These are generally 35 mm. Two sensors (closer/s) are requred for each unt and extenson cables are avalable as an opton. For sensor cables, note the mnmum permssble bendng rad. These are generally 35 mm. 11

12 JGZ 40 Unversal grpper Programmable magnetc swtches MMS-P GN Lmt stop for sensor Poston montorng wth two programmable postons per sensor. End poston montorng for mountng n the C-slot. Descrpton ID Often combned Programmable magnetc swtches MMS-P MMSK-P 22-S-PNP MMS-P 22-S-M8-PNP clp for plug/socket CLI-M Connecton cables KA BG08-L 4P KA BG08-L 4P KA BW08-L 4P KA BW08-L 4P Sensor dstrbutor V2-M8-4P-2XM8-3P Per unt one sensor (closer/s) s requred, optonally a cable extenson. For sensor cables, note the mnmum permssble bendng rad. These are generally 35 mm. 12

13 JGZ 40 Unversal grpper 13

14 JGZ 50 Unversal grpper Grppng force, O.D. grppng Fnger load Grppng force Grppng force, I.D. grppng Pont P - Fnger length M x max. 16 Nm M y max. 20 Nm M z max. 8 Nm F z max. 400 N Grppng force The specfed torques and forces are statc values, apply for each base jaw, and may occur smultaneously. M y may arse n addton to the moment generated by the grppng force tself. Pont P - Fnger length Techncal data Descrpton JGZ 50-1 JGZ 50-1-AS JGZ 50-1-IS ID Stroke per jaw [mm] Closng / openng force [N] 325/ /- -/505 Mn. sprng force [N] Weght [kg] Recommended workpece weght [kg] Flud consumpton double stroke [cm³] Mn./max. operatng pressure [bar] 2/8 4/6.5 4/6.5 Nomnal operatng pressure [bar] Mn./max. ar purge pressure [bar] 0.5/1 0.5/1 0.5/1 Closng/openng tme [s] 0.03/ / /0.02 Closng- / openng tme wth sprng [s] Max. permssble fnger length [mm] Max. permssble mass per fnger [kg] Protecton class IP Mn./max. ambent temperature [ C] 5/90 5/90 5/90 Repeat accuracy [mm] Cleanroom class ISO

15 JGZ 50 Unversal grpper Man vew The drawng shows the grpper n the basc verson wth closed jaws, wthout dmensonal consderaton of the optons descrbed below. The SDV-P pressure mantenance valve can also be used for I.D. or O.D. grppng alternatvely or n addton to the sprng-loaded, mechancal grppng force mantenance devce (see catalog secton on accessores). A, a Man / drect connecton, grpper openng B, b Man / drect connecton, grpper closng S Ar purge connecton 1 Grpper connecton 2 Fnger connecton BN Bolt crcle GL Ft for centerng sleeves GM Ft for centerng pns HT Depth of the centerng sleeve hole n the counter part IT Thread below the cover for fastenng external attachments IK Sensor MMS

16 JGZ 50 Unversal grpper Hose-free drect connecton M3 Grppng force mantenance devce AS / IS 3 Adapter 4 Grppers The drect connecton s used for supplyng compressed ar wthout hoses. Instead, the pressure medum s fed through bore-holes n the mountng plate. The mechancal grppng force mantenance devce ensures that a mnmum clampng force wll be appled even f there s a drop n pressure. Ths acts as closng force n the AS / S verson, and as openng force n the IS verson. Besdes ths, the grppng force mantenance devce can be used to ncrease the grppng force or for sngle actuated grppng. Sprng-loaded pressure pece SDV-P pressure mantenance valve For sprng-supported postonng of the workpece aganst a stop after the grpper has opened. Especally developed for loadng machnes. Descrpton ID Stroke Mn. force [mm] [N] Sprng-loaded pressure pece A-PZN-plus Grppers IT SDV-P pressure mantenance valve The SDV-P pressure mantenance valve ensures n emergency STOP stuatons that the pressure n the pston chamber of pneumatc grpper, swvel, lnear, and quck-change modules s temporarly mantaned. Descrpton ID Pressure mantenance valve SDV-P Pressure mantenance valve wth ar bleed screw SDV-P 04-E

17 JGZ 50 Unversal grpper BSWS jaw quck-change jaw systems ZBA-L-plus 50 ntermedate jaws 4 Grppers IT Customzed grpper fngers There are varous jaw quck-change systems avalable for the grpper. For detaled nformaton, please refer to the correspondng product. Descrpton ID Quck-change jaw system adapter BSWS-A BSWS-AR Quck-change jaw system base BSWS-B Jaw quck-change system BSWS-ABR-PGZN-plus BSWS-SBR-PGZN-plus Quck-change Jaw System reversed BSWS-UR Fnger connecton EP Included n the scope of delvery GL Ft for centerng sleeves HT Depth of the centerng sleeve hole n the counter part HK Not ncluded n the scope of delvery The optonal ZBA-L-plus ntermedate jaws allow the screw connecton dagram of the top jaws to be rotated by 90. Ths makes t easer to desgn and produce top jaws (partcularly for long versons) because no deep through-bores are requred. Descrpton ID Materal Fnger Scope of delvery nterface Intermedate jaws ZBA-L-plus Alumnum PGN-plus 50 1 Only systems that are lsted n the table, can be used. 17

18 JGZ 50 Unversal grpper UZB 50 unversal ntermedate jaw Force-measurng jaws FMS-ZBA/ZBP 50 1 Grpper connecton 2 Fnger connecton EN Optonal rght or left connecton EQ Lockng GL Ft for centerng sleeves HT Depth of the centerng sleeve hole n the counter part The drawng shows the UZB unversal ntermedate jaw. Descrpton ID Grd dmenson [mm] Unversal ntermedate jaw UZB Fnger blanks ABR-PGZN-plus SBR-PGZN-plus Grpper connecton 2 Fnger connecton AQ Cable outlet GL Ft for centerng sleeves HT Depth of the centerng sleeve hole n the counter part IT Actve ntermedate jaws IK Passve ntermedate jaws Force-measurng jaws measure grppng forces, but can also determne workpece weghts or dmensonal devatons. There are actve and passve ntermedate jaws (FMS-ZBA or FMS-ZBP). At least one actve force-measurng jaw s requred per grpper, the rest can be passve. For each actve jaw, a FMS-A1 evaluaton unt and a FMS-A connecton cable are requred. Descrpton ID Often combned Actve ntermedate jaws FMS-ZBA Passve ntermedate jaws FMS-ZBP Connecton cables FMS-AK FMS-AK FMS-AK FMS-AK Evaluaton electroncs FMS-A Due to the screw length, the FMS system can not be used n combnaton wth the opton dust-proof (SD) of the grpper. Please note that the admssble force range of the force measurng jaw (see catalog chapter FMS) should not be exceeded for the chosen grpper verson. 18

19 JGZ 50 Unversal grpper Fnger blank ABR- / SBR-PGZN-plus 50 TCU tolerance compensaton unt 2 Fnger connecton GL Ft for centerng sleeves The drawng shows the fnger blank whch can be reworked by the customer. Descrpton ID Materal Scope of delvery Fnger blanks ABR-PGZN-plus Alumnum 1 SBR-PGZN-plus MnCr5 1 IT montorng of lockng Grppers can be drectly mounted wthout an adapter plate. Tolerance compensaton unt and grpper have an dentcal screw connecton dagram. Therefore the tolerance compensaton unts can be assembled later. Please consder the addtonal assembly heght of the tolerance compensaton unt. For detals please refer to our catalog robot accessores. Descrpton ID Lockng Deflecton Compensaton unt TCU-Z OV no ±1 /±1 /±1,5 XY compensaton unt wth sprng return Modular Assembly Automaton IT Montorng Grppers can be drectly mounted wthout an adapter plate. For detals see our catalog Grppng or Robot Accessores. Descrpton ID Compensaton XY Reset force [mm] [N] Compensaton unt AGE-F-XY ± 2 2 AGE-F-XY ± Often combned AGE-F-XY ± Grppers IT CLM/KLM/LM/ELP/ELM/ELS/HLM lnear modules IK ASG adapter plate Grppers and lnear modules can be combned wth standard adapter plates from the modular assembly system. For more nformaton see our man catalog "Modular Assembly Automaton". 19

20 JGZ 50 Unversal grpper Electronc magnetc swtches MMS Programmable magnetc swtch MMS 22-PI1 AQ Cable outlet IT Sensor MMS 22.. IK Sensor MMS SA AQ Cable outlet IT Sensor MMS 22 PI1-... IK Sensor MMS 22..-PI1-...-SA End poston montorng for mountng n the C-slot. Descrpton ID Often combned Electronc magnetc swtches MMS MMS 22-S-M8-PNP MMSK 22-S-PNP MMS electronc magnetc swtches wth lateral outlet MMS 22-S-M8-PNP-SA MMSK 22-S-PNP-SA Cable extenson KV BW08-SG08 3P-0030-PNP KV BW08-SG08 3P-0100-PNP KV BW08-SG08 3P-0200-PNP clp for plug/socket CLI-M Connecton cables KA BG08-L 3P-0300-PNP KA BG08-L 3P-0500-PNP KA BW08-L 3P-0300-PNP KA BW08-L 3P-0500-PNP Sensor dstrbutor V2-M V4-M V8-M Poston montorng wth one programmable poston per sensor and electroncs ntegrated n the sensor. Can be programmed usng MT magnetc teachng tool (ncluded n scope of delvery) or ST plug teachng tool (optonal). End poston montorng s mounted n the C-slot. If the ST plug teachng tools are lsted n the table provded, teachng s only possble wth the ST teachng tools. Descrpton ID Often combned Plug teachng tool ST-MMS 22-PI1-PNP Programmable magnetc swtch MMS 22-PI1 MMS 22-PI1-S-M8-PNP MMSK 22-PI1-S-PNP Programmable magnetc swtch MMS 22-PI1 wth lateral connecton MMS 22-PI1-S-M8-PNP-SA MMSK 22-PI1-S-PNP-SA Programmable magnetc swtch MMS 22-PI1 wth stanless steel housng MMS 22-PI1-S-M8-PNP-HD MMSK 22-PI1-S-PNP-HD Two sensors (closer/s) are requred for each unt and extenson cables are avalable as an opton. For sensor cables, note the mnmum permssble bendng rad. These are generally 35 mm. Two sensors (closer/s) are requred for each unt and extenson cables are avalable as an opton. For sensor cables, note the mnmum permssble bendng rad. These are generally 35 mm. 20

21 JGZ 50 Unversal grpper Programmable magnetc swtch MMS 22-PI2 Programmable magnetc swtches MMS-P AQ Cable outlet IT MMS PI2-... sensor GN Lmt stop for sensor Poston montorng wth two programmable postons per sensor and electroncs bult nto the sensor. Can be programmed usng MT magnetc teachng tool (ncluded n the scope of delvery) or ST plug teachng tool (optonal). End poston montorng for mountng n the C-slot. If the ST plug teachng tools are lsted n the table provded, teachng s only possble wth the ST teachng tools. Descrpton ID Often combned Plug teachng tool ST-MMS 22-PI2-PNP Programmable magnetc swtch MMS 22-PI2 MMS 22-PI2-S-M8-PNP MMSK 22-PI2-S-PNP Programmable magnetc swtch MMS 22-PI2 wth stanless steel housng MMS 22-PI2-S-M8-PNP-HD MMSK 22-PI2-S-PNP-HD Per unt one sensor (closer/s) s requred, optonally a cable extenson. For sensor cables, note the mnmum permssble bendng rad. These are generally 35 mm. Poston montorng wth two programmable postons per sensor. End poston montorng for mountng n the C-slot. Descrpton ID Often combned Programmable magnetc swtches MMS-P MMSK-P 22-S-PNP MMS-P 22-S-M8-PNP clp for plug/socket CLI-M Connecton cables KA BG08-L 4P KA BG08-L 4P KA BW08-L 4P KA BW08-L 4P Sensor dstrbutor V2-M8-4P-2XM8-3P Per unt one sensor (closer/s) s requred, optonally a cable extenson. For sensor cables, note the mnmum permssble bendng rad. These are generally 35 mm. 21

22 JGZ 64 Unversal grpper Grppng force, O.D. grppng Fnger load Grppng force Grppng force, I.D. grppng Pont P - Fnger length M x max. 32 Nm M y max. 48 Nm M z max. 32 Nm F z max. 880 N Grppng force The specfed torques and forces are statc values, apply for each base jaw, and may occur smultaneously. M y may arse n addton to the moment generated by the grppng force tself. Pont P - Fnger length Techncal data Descrpton JGZ 64-1 JGZ 64-1-AS JGZ 64-1-IS ID Stroke per jaw [mm] Closng / openng force [N] 580/ /- -/860 Mn. sprng force [N] Weght [kg] Recommended workpece weght [kg] Flud consumpton double stroke [cm³] Mn./max. operatng pressure [bar] 2/8 4/6.5 4/6.5 Nomnal operatng pressure [bar] Mn./max. ar purge pressure [bar] 0.5/1 0.5/1 0.5/1 Closng/openng tme [s] 0.03/ / /0.02 Closng- / openng tme wth sprng [s] Max. permssble fnger length [mm] Max. permssble mass per fnger [kg] Protecton class IP Mn./max. ambent temperature [ C] 5/90 5/90 5/90 Repeat accuracy [mm] Cleanroom class ISO

23 JGZ 64 Unversal grpper Man vew The drawng shows the grpper n the basc verson wth closed jaws, wthout dmensonal consderaton of the optons descrbed below. The SDV-P pressure mantenance valve can also be used for I.D. or O.D. grppng alternatvely or n addton to the sprng-loaded, mechancal grppng force mantenance devce (see catalog secton on accessores). A, a Man / drect connecton, grpper openng B, b Man / drect connecton, grpper closng S Ar purge connecton 1 Grpper connecton 2 Fnger connecton BN Bolt crcle GL Ft for centerng sleeves GM Ft for centerng pns HT Depth of the centerng sleeve hole n the counter part IT Thread below the cover for fastenng external attachments IK Sensor MMS 22.. IL Sensor IN... 23

24 JGZ 64 Unversal grpper Hose-free drect connecton M4 Grppng force mantenance devce AS / IS 3 Adapter 4 Grppers The drect connecton s used for supplyng compressed ar wthout hoses. Instead, the pressure medum s fed through bore-holes n the mountng plate. The mechancal grppng force mantenance devce ensures that a mnmum clampng force wll be appled even f there s a drop n pressure. Ths acts as closng force n the AS / S verson, and as openng force n the IS verson. Besdes ths, the grppng force mantenance devce can be used to ncrease the grppng force or for sngle actuated grppng. Sprng-loaded pressure pece SDV-P pressure mantenance valve For sprng-supported postonng of the workpece aganst a stop after the grpper has opened. Especally developed for loadng machnes. Descrpton ID Stroke Mn. force [mm] [N] Sprng-loaded pressure pece A-PZN-plus/DPZ-plus Grppers IT SDV-P pressure mantenance valve The SDV-P pressure mantenance valve ensures n emergency STOP stuatons that the pressure n the pston chamber of pneumatc grpper, swvel, lnear, and quck-change modules s temporarly mantaned. Descrpton ID Pressure mantenance valve SDV-P Pressure mantenance valve wth ar bleed screw SDV-P 04-E

25 JGZ 64 Unversal grpper BSWS jaw quck-change jaw systems ZBA-L-plus 64 ntermedate jaws 4 Grppers IT Customzed grpper fngers There are varous jaw quck-change systems avalable for the grpper. For detaled nformaton, please refer to the correspondng product. Descrpton ID Quck-change jaw system adapter BSWS-A BSWS-AR Quck-change jaw system base BSWS-B Jaw quck-change system BSWS-ABR-PGZN-plus BSWS-SBR-PGZN-plus Quck-change Jaw System reversed BSWS-UR Fnger connecton EP Included n the scope of delvery GL Ft for centerng sleeves HT Depth of the centerng sleeve hole n the counter part HK Not ncluded n the scope of delvery The optonal ZBA-L-plus ntermedate jaws allow the screw connecton dagram of the top jaws to be rotated by 90. Ths makes t easer to desgn and produce top jaws (partcularly for long versons) because no deep through-bores are requred. Descrpton ID Materal Fnger Scope of delvery nterface Intermedate jaws ZBA-L-plus Alumnum PGN-plus 64 1 Only systems that are lsted n the table, can be used. 25

26 JGZ 64 Unversal grpper UZB 64 unversal ntermedate jaw Force-measurng jaws FMS-ZBA/ ZBP 64 1 Grpper connecton 2 Fnger connecton EN Optonal rght or left connecton EQ Lockng GL Ft for centerng sleeves HT Depth of the centerng sleeve hole n the counter part The drawng shows the UZB unversal ntermedate jaw. Descrpton ID Grd dmenson [mm] Unversal ntermedate jaw UZB Fnger blanks ABR-PGZN-plus SBR-PGZN-plus Grpper connecton 2 Fnger connecton AQ Cable outlet GL Ft for centerng sleeves HT Depth of the centerng sleeve hole n the counter part IT Actve ntermedate jaws IK Passve ntermedate jaws Force-measurng jaws measure grppng forces, but can also determne workpece weghts or dmensonal devatons. There are actve and passve ntermedate jaws (FMS-ZBA or FMS-ZBP). At least one actve force-measurng jaw s requred per grpper, the rest can be passve. For each actve jaw, a FMS-A1 evaluaton unt and a FMS-A connecton cable are requred. Descrpton ID Often combned Actve ntermedate jaws FMS-ZBA Passve ntermedate jaws FMS-ZBP Connecton cables FMS-AK FMS-AK FMS-AK FMS-AK Evaluaton electroncs FMS-A Due to the screw length, the FMS system can not be used n combnaton wth the opton dust-proof (SD) of the grpper. Please note that the admssble force range of the force measurng jaw (see catalog chapter FMS) should not be exceeded for the chosen grpper verson. 26

27 JGZ 64 Unversal grpper Fnger blanks ABR- / SBR-PGZN-plus 64 TCU tolerance compensaton unt 2 Fnger connecton GL Ft for centerng sleeves The drawng shows the fnger blank whch can be reworked by the customer. Descrpton ID Materal Scope of delvery Fnger blanks ABR-PGZN-plus Alumnum 1 SBR-PGZN-plus MnCr5 1 IT montorng of lockng Grppers can be drectly mounted wthout an adapter plate. Tolerance compensaton unt and grpper have an dentcal screw connecton dagram. Therefore the tolerance compensaton unts can be assembled later. Please consder the addtonal assembly heght of the tolerance compensaton unt. For detals please refer to our catalog robot accessores. Descrpton ID Lockng Deflecton Often combned Compensaton unt TCU-Z MV yes ±1 /±1 /±1 TCU-Z OV no ±1 /±1 /±1 XY compensaton unt wth sprng return Modular Assembly Automaton IT Montorng Grppers can be drectly mounted wthout an adapter plate. For detals see our catalog Grppng or Robot Accessores. Descrpton ID Compensaton XY Reset force [mm] [N] Compensaton unt AGE-F-XY ± 4 12 AGE-F-XY ± 4 13 Often combned AGE-F-XY ± Grppers IT CLM/KLM/LM/ELP/ELM/ELS/HLM lnear modules IK ASG adapter plate Grppers and lnear modules can be combned wth standard adapter plates from the modular assembly system. For more nformaton see our man catalog "Modular Assembly Automaton". 27

28 JGZ 64 Unversal grpper Inductve Proxmty Swtches Flexble poston sensor AQ Cable outlet IT Sensor IN... Drectly mounted end poston montorng. IK Sensor IN..-SA Descrpton ID Often combned Inductve Proxmty Swtches IN 80-S-M IN 80-S-M INK 80-S Inductve proxmty swtch wth lateral outlet IN 80-S-M12-SA IN 80-S-M8-SA INK 80-S-SA Cable extenson KV BG12-SG12 3P-0030-PNP KV BG12-SG12 3P-0060-PNP KV BW08-SG08 3P-0030-PNP KV BW08-SG08 3P-0100-PNP KV BW08-SG08 3P-0200-PNP KV BW12-SG12 3P-0030-PNP KV BW12-SG12 3P-0100-PNP KV BW12-SG12 3P-0200-PNP clp for plug/socket CLI-M CLI-M Connecton cables KA BG08-L 3P-0300-PNP KA BG08-L 3P-0500-PNP KA BG12-L 3P-0500-PNP KA BW08-L 3P-0300-PNP KA BW08-L 3P-0500-PNP KA BW12-L 3P-0300-PNP KA BW12-L 3P-0500-PNP Sensor dstrbutor V2-M V2-M V4-M V4-M V8-M V8-M IT FPS-S sensor Flexble poston montorng of up to fve postons. Descrpton ID Attachment kt for FPS AS-FPS-PGZN-plus 64-1/ Sensor FPS-S M Cable extenson KV BG08-SG08 3P KV BG08-SG08 3P Evaluaton electroncs FPS-F IK FPS-F5 evaluaton electronc When usng an FPS system, an FPS sensor (FPS-S) as well as an electronc processor (FPS-F5 / F5 T) are requred for each grpper as well as a mountng kt (AS), f lsted. Cable extensons (KV) are optonally avalable - see catalog chapter Accessores. Two sensors (closer/s) are requred for each unt and extenson cables are avalable as an opton. For sensor cables, note the mnmum permssble bendng rad. These are generally 35 mm. 28

29 JGZ 64 Unversal grpper Electronc magnetc swtches MMS Programmable magnetc swtch MMS 22-PI1 AQ Cable outlet IT Sensor MMS 22.. IK Sensor MMS SA AQ Cable outlet IT Sensor MMS 22 PI1-... IK Sensor MMS 22..-PI1-...-SA End poston montorng for mountng n the C-slot. Descrpton ID Often combned Electronc magnetc swtches MMS MMS 22-S-M8-PNP MMSK 22-S-PNP MMS electronc magnetc swtches wth lateral outlet MMS 22-S-M8-PNP-SA MMSK 22-S-PNP-SA Cable extenson KV BW08-SG08 3P-0030-PNP KV BW08-SG08 3P-0100-PNP KV BW08-SG08 3P-0200-PNP clp for plug/socket CLI-M Connecton cables KA BG08-L 3P-0300-PNP KA BG08-L 3P-0500-PNP KA BW08-L 3P-0300-PNP KA BW08-L 3P-0500-PNP Sensor dstrbutor V2-M V4-M V8-M Poston montorng wth one programmable poston per sensor and electroncs ntegrated n the sensor. Can be programmed usng MT magnetc teachng tool (ncluded n scope of delvery) or ST plug teachng tool (optonal). End poston montorng s mounted n the C-slot. If the ST plug teachng tools are lsted n the table provded, teachng s only possble wth the ST teachng tools. Descrpton ID Often combned Plug teachng tool ST-MMS 22-PI1-PNP Programmable magnetc swtch MMS 22-PI1 MMS 22-PI1-S-M8-PNP MMSK 22-PI1-S-PNP Programmable magnetc swtch MMS 22-PI1 wth lateral connecton MMS 22-PI1-S-M8-PNP-SA MMSK 22-PI1-S-PNP-SA Programmable magnetc swtch MMS 22-PI1 wth stanless steel housng MMS 22-PI1-S-M8-PNP-HD MMSK 22-PI1-S-PNP-HD Two sensors (closer/s) are requred for each unt and extenson cables are avalable as an opton. For sensor cables, note the mnmum permssble bendng rad. These are generally 35 mm. Two sensors (closer/s) are requred for each unt and extenson cables are avalable as an opton. For sensor cables, note the mnmum permssble bendng rad. These are generally 35 mm. 29

30 JGZ 64 Unversal grpper Programmable magnetc swtch MMS 22-PI2 Programmable magnetc swtches MMS-P AQ Cable outlet IT MMS PI2-... sensor GN Lmt stop for sensor Poston montorng wth two programmable postons per sensor and electroncs bult nto the sensor. Can be programmed usng MT magnetc teachng tool (ncluded n the scope of delvery) or ST plug teachng tool (optonal). End poston montorng for mountng n the C-slot. If the ST plug teachng tools are lsted n the table provded, teachng s only possble wth the ST teachng tools. Descrpton ID Often combned Plug teachng tool ST-MMS 22-PI2-PNP Programmable magnetc swtch MMS 22-PI2 MMS 22-PI2-S-M8-PNP MMSK 22-PI2-S-PNP Programmable magnetc swtch MMS 22-PI2 wth stanless steel housng MMS 22-PI2-S-M8-PNP-HD MMSK 22-PI2-S-PNP-HD Per unt one sensor (closer/s) s requred, optonally a cable extenson. For sensor cables, note the mnmum permssble bendng rad. These are generally 35 mm. Poston montorng wth two programmable postons per sensor. End poston montorng for mountng n the C-slot. Descrpton ID Often combned Programmable magnetc swtches MMS-P MMSK-P 22-S-PNP MMS-P 22-S-M8-PNP clp for plug/socket CLI-M Connecton cables KA BG08-L 4P KA BG08-L 4P KA BW08-L 4P KA BW08-L 4P Sensor dstrbutor V2-M8-4P-2XM8-3P Per unt one sensor (closer/s) s requred, optonally a cable extenson. For sensor cables, note the mnmum permssble bendng rad. These are generally 35 mm. 30

31 JGZ 64 Unversal grpper APS-Z80 analog poston sensor APS-M1 analog poston sensor No-contact measurng, analog mult-poston montorng for any number of postons. Descrpton ID Often combned Mountng kt for APS-Z80 AS-APS-Z80-PGZN-plus Sensor APS-Z80-K APS-Z80-M When usng an APS system, one attachment kt (AS-APS-Z80) and one APS-Z80 sensor are requred per grpper. IT APS-M1S sensor IK APS-M1E electronc processor IL APS-K extenson cable Analog mult poston montorng for any desred postons Descrpton ID Mountng kt for APS-M1 AS-APS-M1-PGZN-plus Sensor APS-M1S When usng an APS system, for each grpper an attachment kt (AS-APS-M1), an APS-M1S sensor (ncl. 3 m cable) as well as an electroncs (APS-M1e) are requred. An extenson cable (APS-K) can be connected between the sensor and the electroncs as an opton. The max. cable length between the sensor and the electroncs s 10 m, between the electroncs and ther control unt (PLC) t s max. 1 m. Cylndrcal reed swtches End poston montorng can be mounted wth an attachment kt. Descrpton ID Attachment kt for proxmty swtch AS-RMS 80 PGN/PZN-plus 64/ Reed Swtches RMS 80-S-M Two sensors (closer/s) are requred for each unt and extenson cables are avalable as an opton. Ths attachment kt needs to be ordered optonally as an accessory. Two mountng kts are requred for each grpper. For sensor cables, note the mnmum permssble bendng rad. These are generally 35 mm. 31

32 JGZ 80 Unversal grpper Grppng force, O.D. grppng Fnger load Grppng force Grppng force, I.D. grppng Pont P - Fnger length M x max. 48 Nm M y max. 76 Nm M z max. 44 Nm F z max N Grppng force The specfed torques and forces are statc values, apply for each base jaw, and may occur smultaneously. M y may arse n addton to the moment generated by the grppng force tself. Pont P - Fnger length Techncal data Descrpton JGZ 80-1 JGZ 80-1-AS JGZ 80-1-IS ID Stroke per jaw [mm] Closng / openng force [N] 1000/ /- -/1450 Mn. sprng force [N] Weght [kg] Recommended workpece weght [kg] Flud consumpton double stroke [cm³] Mn./max. operatng pressure [bar] 2/8 4/6.5 4/6.5 Nomnal operatng pressure [bar] Mn./max. ar purge pressure [bar] 0.5/1 0.5/1 0.5/1 Closng/openng tme [s] 0.05/ / /0.04 Closng- / openng tme wth sprng [s] Max. permssble fnger length [mm] Max. permssble mass per fnger [kg] Protecton class IP Mn./max. ambent temperature [ C] 5/90 5/90 5/90 Repeat accuracy [mm] Cleanroom class ISO

33 JGZ 80 Unversal grpper Man vew The drawng shows the grpper n the basc verson wth closed jaws, wthout dmensonal consderaton of the optons descrbed below. The SDV-P pressure mantenance valve can also be used for I.D. or O.D. grppng alternatvely or n addton to the sprng-loaded, mechancal grppng force mantenance devce (see catalog secton on accessores). A, a Man / drect connecton, grpper openng B, b Man / drect connecton, grpper closng S Ar purge connecton 1 Grpper connecton 2 Fnger connecton BN Bolt crcle GL Ft for centerng sleeves GM Ft for centerng pns HT Depth of the centerng sleeve hole n the counter part IT Thread below the cover for fastenng external attachments IK Sensor MMS 22.. IL Sensor IN... 33

34 JGZ 80 Unversal grpper Hose-free drect connecton M4 Grppng force mantenance devce AS / IS 3 Adapter 4 Grppers The drect connecton s used for supplyng compressed ar wthout hoses. Instead, the pressure medum s fed through bore-holes n the mountng plate. The mechancal grppng force mantenance devce ensures that a mnmum clampng force wll be appled even f there s a drop n pressure. Ths acts as closng force n the AS / S verson, and as openng force n the IS verson. Besdes ths, the grppng force mantenance devce can be used to ncrease the grppng force or for sngle actuated grppng. Sprng-loaded pressure pece SDV-P pressure mantenance valve For sprng-supported postonng of the workpece aganst a stop after the grpper has opened. Especally developed for loadng machnes. Descrpton ID Stroke Mn. force [mm] [N] Sprng-loaded pressure pece A-PZN-plus/DPZ-plus Grppers IT SDV-P pressure mantenance valve The SDV-P pressure mantenance valve ensures n emergency STOP stuatons that the pressure n the pston chamber of pneumatc grpper, swvel, lnear, and quck-change modules s temporarly mantaned. Descrpton ID Pressure mantenance valve SDV-P Pressure mantenance valve wth ar bleed screw SDV-P 04-E

35 JGZ 80 Unversal grpper BSWS jaw quck-change jaw systems ZBA-L-plus 80 ntermedate jaws 4 Grppers IT Customzed grpper fngers There are varous jaw quck-change systems avalable for the grpper. For detaled nformaton, please refer to the correspondng product. Descrpton ID Quck-change jaw system adapter BSWS-A BSWS-AR Quck-change jaw system base BSWS-B Jaw quck-change system BSWS-ABR-PGZN-plus BSWS-SBR-PGZN-plus Quck-change Jaw System reversed BSWS-UR Fnger connecton EP Included n the scope of delvery GL Ft for centerng sleeves HT Depth of the centerng sleeve hole n the counter part HK Not ncluded n the scope of delvery The optonal ZBA-L-plus ntermedate jaws allow the screw connecton dagram of the top jaws to be rotated by 90. Ths makes t easer to desgn and produce top jaws (partcularly for long versons) because no deep through-bores are requred. Descrpton ID Materal Fnger Scope of delvery nterface Intermedate jaws ZBA-L-plus Alumnum PGN-plus 80 1 Only systems that are lsted n the table, can be used. 35

36 JGZ 80 Unversal grpper UZB 80 unversal ntermedate jaw Force-measurng jaws FMS-ZBA/ ZBP 80 1 Grpper connecton 2 Fnger connecton EN Optonal rght or left connecton EQ Lockng GL Ft for centerng sleeves HT Depth of the centerng sleeve hole n the counter part The drawng shows the UZB unversal ntermedate jaw. The fully removable UZB-S slde (can also be ordered separately) allows for a quck jaw change. Descrpton ID Grd dmenson [mm] Unversal ntermedate jaw UZB UZB-S Fnger blanks ABR-PGZN-plus SBR-PGZN-plus Grpper connecton 2 Fnger connecton AQ Cable outlet GL Ft for centerng sleeves HT Depth of the centerng sleeve hole n the counter part IT Actve ntermedate jaws IK Passve ntermedate jaws Force-measurng jaws measure grppng forces, but can also determne workpece weghts or dmensonal devatons. There are actve and passve ntermedate jaws (FMS-ZBA or FMS-ZBP). At least one actve force-measurng jaw s requred per grpper, the rest can be passve. For each actve jaw, a FMS-A1 evaluaton unt and a FMS-A connecton cable are requred. Descrpton ID Often combned Actve ntermedate jaws FMS-ZBA Passve ntermedate jaws FMS-ZBP Connecton cables FMS-AK FMS-AK FMS-AK FMS-AK Evaluaton electroncs FMS-A Due to the screw length, the FMS system can not be used n combnaton wth the opton dust-proof (SD) of the grpper. Please note that the admssble force range of the force measurng jaw (see catalog chapter FMS) should not be exceeded for the chosen grpper verson. 36

37 JGZ 80 Unversal grpper Fnger blanks ABR- / SBR-PGZN-plus 80 TCU tolerance compensaton unt 2 Fnger connecton GL Ft for centerng sleeves IT ABR-PGZN-plus IK SBR-PGZN-plus The drawng shows the fnger blank whch can be reworked by the customer. Descrpton ID Materal Scope of delvery Fnger blanks ABR-PGZN-plus Alumnum 1 SBR-PGZN-plus MnCr5 1 IT montorng of lockng Grppers can be drectly mounted wthout an adapter plate. Tolerance compensaton unt and grpper have an dentcal screw connecton dagram. Therefore the tolerance compensaton unts can be assembled later. Please consder the addtonal assembly heght of the tolerance compensaton unt. For detals please refer to our catalog robot accessores. Descrpton ID Lockng Deflecton Often combned Compensaton unt TCU-Z MV yes ±1 /±1 /±1 TCU-Z OV no ±1 /±1 /±1 XY compensaton unt wth sprng return Modular Assembly Automaton IT Montorng Grppers can be drectly mounted wthout an adapter plate. For detals see our catalog Grppng or Robot Accessores. Descrpton ID Compensaton XY Reset force [mm] [N] Compensaton unt AGE-F-XY ± 4 12 AGE-F-XY ± 4 13 Often combned AGE-F-XY ± Grppers IT CLM/KLM/LM/ELP/ELM/ELS/HLM lnear modules IK ASG adapter plate Grppers and lnear modules can be combned wth standard adapter plates from the modular assembly system. For more nformaton see our man catalog "Modular Assembly Automaton". 37

38 JGZ 80 Unversal grpper Inductve Proxmty Swtches Flexble poston sensor AQ Cable outlet IT Sensor IN... Drectly mounted end poston montorng. IK Sensor IN..-SA Descrpton ID Often combned Inductve Proxmty Swtches IN 80-S-M IN 80-S-M INK 80-S Inductve proxmty swtch wth lateral outlet IN 80-S-M12-SA IN 80-S-M8-SA INK 80-S-SA Cable extenson KV BG12-SG12 3P-0030-PNP KV BG12-SG12 3P-0060-PNP KV BW08-SG08 3P-0030-PNP KV BW08-SG08 3P-0100-PNP KV BW08-SG08 3P-0200-PNP KV BW12-SG12 3P-0030-PNP KV BW12-SG12 3P-0100-PNP KV BW12-SG12 3P-0200-PNP clp for plug/socket CLI-M CLI-M Connecton cables KA BG08-L 3P-0300-PNP KA BG08-L 3P-0500-PNP KA BG12-L 3P-0500-PNP KA BW08-L 3P-0300-PNP KA BW08-L 3P-0500-PNP KA BW12-L 3P-0300-PNP KA BW12-L 3P-0500-PNP Sensor dstrbutor V2-M V2-M V4-M V4-M V8-M V8-M IT FPS-S sensor Flexble poston montorng of up to fve postons. IK FPS-F5 evaluaton electronc Descrpton ID Attachment kt for FPS AS-FPS-PGZN-plus 80-1/PZB 80/PZB Sensor FPS-S M Cable extenson KV BG08-SG08 3P KV BG08-SG08 3P Evaluaton electroncs FPS-F When usng an FPS system, an FPS sensor (FPS-S) as well as an electronc processor (FPS-F5 / F5 T) are requred for each grpper as well as a mountng kt (AS), f lsted. Cable extensons (KV) are optonally avalable - see catalog chapter Accessores. Two sensors (closer/s) are requred for each unt and extenson cables are avalable as an opton. For sensor cables, note the mnmum permssble bendng rad. These are generally 35 mm. 38

39 JGZ 80 Unversal grpper Electronc magnetc swtches MMS Programmable magnetc swtch MMS 22-PI1 End poston montorng for mountng n the C-slot. Descrpton ID Often combned Electronc magnetc swtches MMS MMS 22-S-M8-PNP MMSK 22-S-PNP MMS electronc magnetc swtches wth lateral outlet MMS 22-S-M8-PNP-SA MMSK 22-S-PNP-SA Reed Swtches RMS 22-S-M Cable extenson KV BW08-SG08 3P-0030-PNP KV BW08-SG08 3P-0100-PNP KV BW08-SG08 3P-0200-PNP clp for plug/socket CLI-M Connecton cables KA BG08-L 3P-0300-PNP KA BG08-L 3P-0500-PNP KA BW08-L 3P-0300-PNP KA BW08-L 3P-0500-PNP RSS Wreless sensor system RSS-T RSS-T2-US/CA Sensor dstrbutor V2-M V4-M V8-M AQ Cable outlet IT Sensor MMS 22 PI1-... IK Sensor MMS 22..-PI1-...-SA Poston montorng wth one programmable poston per sensor and electroncs ntegrated n the sensor. Can be programmed usng MT magnetc teachng tool (ncluded n scope of delvery) or ST plug teachng tool (optonal). End poston montorng s mounted n the C-slot. If the ST plug teachng tools are lsted n the table provded, teachng s only possble wth the ST teachng tools. Descrpton ID Often combned Programmable magnetc swtch MMS 22-PI1 MMS 22-PI1-S-M8-PNP MMSK 22-PI1-S-PNP Programmable magnetc swtch MMS 22-PI1 wth lateral connecton MMS 22-PI1-S-M8-PNP-SA MMSK 22-PI1-S-PNP-SA Programmable magnetc swtch MMS 22-PI1 wth stanless steel housng MMS 22-PI1-S-M8-PNP-HD MMSK 22-PI1-S-PNP-HD Two sensors (closer/s) are requred for each unt and extenson cables are avalable as an opton. For sensor cables, note the mnmum permssble bendng rad. These are generally 35 mm. Two sensors (closer/s) are requred for each unt and extenson cables are avalable as an opton. For sensor cables, note the mnmum permssble bendng rad. These are generally 35 mm. 39

40 JGZ 80 Unversal grpper Programmable magnetc swtch MMS 22-PI2 Programmable magnetc swtches MMS-P AQ Cable outlet IT MMS PI2-... sensor GN Lmt stop for sensor Poston montorng wth two programmable postons per sensor and electroncs bult nto the sensor. Can be programmed usng MT magnetc teachng tool (ncluded n the scope of delvery) or ST plug teachng tool (optonal). End poston montorng for mountng n the C-slot. If the ST plug teachng tools are lsted n the table provded, teachng s only possble wth the ST teachng tools. Descrpton ID Often combned Programmable magnetc swtch MMS 22-PI2 MMS 22-PI2-S-M8-PNP MMSK 22-PI2-S-PNP Programmable magnetc swtch MMS 22-PI2 wth stanless steel housng MMS 22-PI2-S-M8-PNP-HD MMSK 22-PI2-S-PNP-HD Per unt one sensor (closer/s) s requred, optonally a cable extenson. For sensor cables, note the mnmum permssble bendng rad. These are generally 35 mm. Poston montorng wth two programmable postons per sensor. End poston montorng for mountng n the C-slot. Descrpton ID Often combned Programmable magnetc swtches MMS-P MMSK-P 22-S-PNP MMS-P 22-S-M8-PNP clp for plug/socket CLI-M Connecton cables KA BG08-L 4P KA BG08-L 4P KA BW08-L 4P KA BW08-L 4P Sensor dstrbutor V2-M8-4P-2XM8-3P Per unt one sensor (closer/s) s requred, optonally a cable extenson. For sensor cables, note the mnmum permssble bendng rad. These are generally 35 mm. 40

41 JGZ 80 Unversal grpper APS-Z80 analog poston sensor APS-M1 analog poston sensor No-contact measurng, analog mult-poston montorng for any number of postons. Descrpton ID Often combned Mountng kt for APS-Z80 AS-APS-Z80-PGZN-plus Sensor APS-Z80-K APS-Z80-M When usng an APS system, one attachment kt (AS-APS-Z80) and one APS-Z80 sensor are requred per grpper. IT APS-M1S sensor IK APS-M1E electronc processor IL APS-K extenson cable Analog mult poston montorng for any desred postons Descrpton ID Mountng kt for APS-M1 AS-APS-M1-PGZN-plus Sensor APS-M1S When usng an APS system, for each grpper an attachment kt (AS-APS-M1), an APS-M1S sensor (ncl. 3 m cable) as well as an electroncs (APS-M1e) are requred. An extenson cable (APS-K) can be connected between the sensor and the electroncs as an opton. The max. cable length between the sensor and the electroncs s 10 m, between the electroncs and ther control unt (PLC) t s max. 1 m. Cylndrcal reed swtches End poston montorng can be mounted wth an attachment kt. Descrpton ID Attachment kt for proxmty swtch AS-RMS 80 PGN/PZN-plus 64/ Reed Swtches RMS 80-S-M Two sensors (closer/s) are requred for each unt and extenson cables are avalable as an opton. Ths attachment kt needs to be ordered optonally as an accessory. Two mountng kts are requred for each grpper. For sensor cables, note the mnmum permssble bendng rad. These are generally 35 mm. 41

42 JGZ 100 Unversal grpper Grppng force, O.D. grppng Fnger load Grppng force Grppng force, I.D. grppng Pont P - Fnger length M x max. 65 Nm M y max. 92 Nm M z max. 55 Nm F z max N Grppng force The specfed torques and forces are statc values, apply for each base jaw, and may occur smultaneously. M y may arse n addton to the moment generated by the grppng force tself. Pont P - Fnger length Techncal data Descrpton JGZ JGZ AS JGZ IS ID Stroke per jaw [mm] Closng / openng force [N] 1800/ /- -/2700 Mn. sprng force [N] Weght [kg] Recommended workpece weght [kg] Flud consumpton double stroke [cm³] Mn./max. operatng pressure [bar] 2/8 4/6.5 4/6.5 Nomnal operatng pressure [bar] Mn./max. ar purge pressure [bar] 0.5/1 0.5/1 0.5/1 Closng/openng tme [s] 0.1/ / /0.1 Closng- / openng tme wth sprng [s] Max. permssble fnger length [mm] Max. permssble mass per fnger [kg] Protecton class IP Mn./max. ambent temperature [ C] 5/90 5/90 5/90 Repeat accuracy [mm] Cleanroom class ISO

43 JGZ 100 Unversal grpper Man vew The drawng shows the grpper n the basc verson wth closed jaws, wthout dmensonal consderaton of the optons descrbed below. The SDV-P pressure mantenance valve can also be used for I.D. or O.D. grppng alternatvely or n addton to the sprng-loaded, mechancal grppng force mantenance devce (see catalog secton on accessores). A, a Man / drect connecton, grpper openng B, b Man / drect connecton, grpper closng S Ar purge connecton 1 Grpper connecton 2 Fnger connecton BN Bolt crcle GL Ft for centerng sleeves GM Ft for centerng pns HT Depth of the centerng sleeve hole n the counter part IT Thread below the cover for fastenng external attachments IK Sensor MMS 22.. IL Sensor IN... 43

44 JGZ 100 Unversal grpper Hose-free drect connecton M5 Grppng force mantenance devce AS / IS 3 Adapter 4 Grppers The drect connecton s used for supplyng compressed ar wthout hoses. Instead, the pressure medum s fed through bore-holes n the mountng plate. The mechancal grppng force mantenance devce ensures that a mnmum clampng force wll be appled even f there s a drop n pressure. Ths acts as closng force n the AS / S verson, and as openng force n the IS verson. Besdes ths, the grppng force mantenance devce can be used to ncrease the grppng force or for sngle actuated grppng. Sprng-loaded pressure pece SDV-P pressure mantenance valve For sprng-supported postonng of the workpece aganst a stop after the grpper has opened. Especally developed for loadng machnes. Descrpton ID Stroke Mn. force [mm] [N] Sprng-loaded pressure pece A-PZN-plus/DPZ-plus Grppers IT SDV-P pressure mantenance valve The SDV-P pressure mantenance valve ensures n emergency STOP stuatons that the pressure n the pston chamber of pneumatc grpper, swvel, lnear, and quck-change modules s temporarly mantaned. Descrpton ID Pressure mantenance valve SDV-P Pressure mantenance valve wth ar bleed screw SDV-P 04-E

45 JGZ 100 Unversal grpper BSWS jaw quck-change jaw systems ZBA-L-plus 100 ntermedate jaws 4 Grppers IT Customzed grpper fngers There are varous jaw quck-change systems avalable for the grpper. For detaled nformaton, please refer to the correspondng product. Descrpton ID Quck-change jaw system adapter BSWS-A BSWS-AR Quck-change jaw system base BSWS-B Jaw quck-change system BSWS-ABR-PGZN-plus BSWS-SBR-PGZN-plus Quck-change Jaw System reversed BSWS-UR Fnger connecton EP Included n the scope of delvery GL Ft for centerng sleeves HT Depth of the centerng sleeve hole n the counter part HK Not ncluded n the scope of delvery The optonal ZBA-L-plus ntermedate jaws allow the screw connecton dagram of the top jaws to be rotated by 90. Ths makes t easer to desgn and produce top jaws (partcularly for long versons) because no deep through-bores are requred. Descrpton ID Materal Fnger nterface Intermedate jaws ZBA-L-plus Alumnum PGN-plus 100 Scope of delvery 1 Only systems that are lsted n the table, can be used. 45

46 JGZ 100 Unversal grpper UZB 100 unversal ntermedate jaw Force-measurng jaws FMS-ZBA/ ZBP Grpper connecton 2 Fnger connecton EN Optonal rght or left connecton EQ Lockng GL Ft for centerng sleeves HT Depth of the centerng sleeve hole n the counter part The drawng shows the UZB unversal ntermedate jaw. The fully removable UZB-S slde (can also be ordered separately) allows for a quck jaw change. Descrpton ID Grd dmenson [mm] Unversal ntermedate jaw UZB UZB-S Fnger blanks ABR-PGZN-plus SBR-PGZN-plus Grpper connecton 2 Fnger connecton AQ Cable outlet GL Ft for centerng sleeves HT Depth of the centerng sleeve hole n the counter part IT Actve ntermedate jaws IK Passve ntermedate jaws Force-measurng jaws measure grppng forces, but can also determne workpece weghts or dmensonal devatons. There are actve and passve ntermedate jaws (FMS-ZBA or FMS-ZBP). At least one actve force-measurng jaw s requred per grpper, the rest can be passve. For each actve jaw, a FMS-A1 evaluaton unt and a FMS-A connecton cable are requred. Descrpton ID Often combned Actve ntermedate jaws FMS-ZBA Passve ntermedate jaws FMS-ZBP Connecton cables FMS-AK FMS-AK FMS-AK FMS-AK Evaluaton electroncs FMS-A Due to the screw length, the FMS system can not be used n combnaton wth the opton dust-proof (SD) of the grpper. Please note that the admssble force range of the force measurng jaw (see catalog chapter FMS) should not be exceeded for the chosen grpper verson. 46

47 JGZ 100 Unversal grpper Fnger blanks ABR- / SBR-PGZN-plus 100 TCU tolerance compensaton unt 2 Fnger connecton GL Ft for centerng sleeves The drawng shows the fnger blank whch can be reworked by the customer. Descrpton ID Materal Scope of delvery Fnger blanks ABR-PGZN-plus Alumnum 1 SBR-PGZN-plus MnCr5 1 IT montorng of lockng Grppers can be drectly mounted wthout an adapter plate. Tolerance compensaton unt and grpper have an dentcal screw connecton dagram. Therefore the tolerance compensaton unts can be assembled later. Please consder the addtonal assembly heght of the tolerance compensaton unt. For detals please refer to our catalog robot accessores. Descrpton ID Lockng Deflecton Often combned Compensaton unt TCU-Z MV yes ±1 /±1 /±1 TCU-Z OV no ±1 /±1 /±1 XY compensaton unt wth sprng return Modular Assembly Automaton IT Montorng Grppers can be drectly mounted wthout an adapter plate. For detals see our catalog Grppng or Robot Accessores. Descrpton ID Compensaton XY Reset force [mm] [N] Compensaton unt AGE-F-XY ± 5 36 AGE-F-XY ± 5 55 Often combned AGE-F-XY ± Grppers IT CLM/KLM/LM/ELP/ELM/ELS/HLM lnear modules IK ASG adapter plate Grppers and lnear modules can be combned wth standard adapter plates from the modular assembly system. For more nformaton see our man catalog "Modular Assembly Automaton". 47

48 JGZ 100 Unversal grpper Inductve Proxmty Swtches Flexble poston sensor AQ Cable outlet IT Sensor IN... Drectly mounted end poston montorng. IK Sensor IN..-SA Descrpton ID Often combned Inductve Proxmty Swtches IN 80-S-M IN 80-S-M INK 80-S Inductve proxmty swtch wth lateral outlet IN 80-S-M12-SA IN 80-S-M8-SA INK 80-S-SA Cable extenson KV BG12-SG12 3P-0030-PNP KV BG12-SG12 3P-0060-PNP KV BW08-SG08 3P-0030-PNP KV BW08-SG08 3P-0100-PNP KV BW08-SG08 3P-0200-PNP KV BW12-SG12 3P-0030-PNP KV BW12-SG12 3P-0100-PNP KV BW12-SG12 3P-0200-PNP clp for plug/socket CLI-M CLI-M Connecton cables KA BG08-L 3P-0300-PNP KA BG08-L 3P-0500-PNP KA BG12-L 3P-0500-PNP KA BW08-L 3P-0300-PNP KA BW08-L 3P-0500-PNP KA BW12-L 3P-0300-PNP KA BW12-L 3P-0500-PNP Sensor dstrbutor V2-M V2-M V4-M V4-M V8-M V8-M IT FPS-S sensor Flexble poston montorng of up to fve postons. Descrpton ID Attachment kt for FPS AS-FPS-PGZN-plus Sensor FPS-S M Cable extenson KV BG08-SG08 3P KV BG08-SG08 3P Evaluaton electroncs FPS-F IK FPS-F5 evaluaton electronc When usng an FPS system, an FPS sensor (FPS-S) as well as an electronc processor (FPS-F5 / F5 T) are requred for each grpper as well as a mountng kt (AS), f lsted. Cable extensons (KV) are optonally avalable - see catalog chapter Accessores. Two sensors (closer/s) are requred for each unt and extenson cables are avalable as an opton. For sensor cables, note the mnmum permssble bendng rad. These are generally 35 mm. 48

49 JGZ 100 Unversal grpper Electronc magnetc swtches MMS Programmable magnetc swtch MMS 22-PI1 End poston montorng for mountng n the C-slot. Descrpton ID Often combned Electronc magnetc swtches MMS MMS 22-S-M8-PNP MMSK 22-S-PNP MMS electronc magnetc swtches wth lateral outlet MMS 22-S-M8-PNP-SA MMSK 22-S-PNP-SA Reed Swtches RMS 22-S-M Cable extenson KV BW08-SG08 3P-0030-PNP KV BW08-SG08 3P-0100-PNP KV BW08-SG08 3P-0200-PNP clp for plug/socket CLI-M Connecton cables KA BG08-L 3P-0300-PNP KA BG08-L 3P-0500-PNP KA BW08-L 3P-0300-PNP KA BW08-L 3P-0500-PNP RSS Wreless sensor system RSS-T RSS-T2-US/CA Sensor dstrbutor V2-M V4-M V8-M AQ Cable outlet IT Sensor MMS 22 PI1-... IK Sensor MMS 22..-PI1-...-SA Poston montorng wth one programmable poston per sensor and electroncs ntegrated n the sensor. Can be programmed usng MT magnetc teachng tool (ncluded n scope of delvery) or ST plug teachng tool (optonal). End poston montorng s mounted n the C-slot. If the ST plug teachng tools are lsted n the table provded, teachng s only possble wth the ST teachng tools. Descrpton ID Often combned Programmable magnetc swtch MMS 22-PI1 MMS 22-PI1-S-M8-PNP MMSK 22-PI1-S-PNP Programmable magnetc swtch MMS 22-PI1 wth lateral connecton MMS 22-PI1-S-M8-PNP-SA MMSK 22-PI1-S-PNP-SA Programmable magnetc swtch MMS 22-PI1 wth stanless steel housng MMS 22-PI1-S-M8-PNP-HD MMSK 22-PI1-S-PNP-HD Two sensors (closer/s) are requred for each unt and extenson cables are avalable as an opton. For sensor cables, note the mnmum permssble bendng rad. These are generally 35 mm. Two sensors (closer/s) are requred for each unt and extenson cables are avalable as an opton. For sensor cables, note the mnmum permssble bendng rad. These are generally 35 mm. 49

50 JGZ 100 Unversal grpper Programmable magnetc swtch MMS 22-PI2 Programmable magnetc swtches MMS-P AQ Cable outlet IT MMS PI2-... sensor GN Lmt stop for sensor Poston montorng wth two programmable postons per sensor and electroncs bult nto the sensor. Can be programmed usng MT magnetc teachng tool (ncluded n the scope of delvery) or ST plug teachng tool (optonal). End poston montorng for mountng n the C-slot. If the ST plug teachng tools are lsted n the table provded, teachng s only possble wth the ST teachng tools. Descrpton ID Often combned Programmable magnetc swtch MMS 22-PI2 MMS 22-PI2-S-M8-PNP MMSK 22-PI2-S-PNP Programmable magnetc swtch MMS 22-PI2 wth stanless steel housng MMS 22-PI2-S-M8-PNP-HD MMSK 22-PI2-S-PNP-HD Per unt one sensor (closer/s) s requred, optonally a cable extenson. For sensor cables, note the mnmum permssble bendng rad. These are generally 35 mm. Poston montorng wth two programmable postons per sensor. End poston montorng for mountng n the C-slot. Descrpton ID Often combned Programmable magnetc swtches MMS-P MMSK-P 22-S-PNP MMS-P 22-S-M8-PNP clp for plug/socket CLI-M Connecton cables KA BG08-L 4P KA BG08-L 4P KA BW08-L 4P KA BW08-L 4P Sensor dstrbutor V2-M8-4P-2XM8-3P Per unt one sensor (closer/s) s requred, optonally a cable extenson. For sensor cables, note the mnmum permssble bendng rad. These are generally 35 mm. 50

51 JGZ 100 Unversal grpper APS-Z80 analog poston sensor APS-M1 analog poston sensor No-contact measurng, analog mult-poston montorng for any number of postons. Descrpton ID Often combned Mountng kt for APS-Z80 AS-APS-Z80-PGZN-plus Sensor APS-Z80-K APS-Z80-M When usng an APS system, one attachment kt (AS-APS-Z80) and one APS-Z80 sensor are requred per grpper. IT APS-M1S sensor IK APS-M1E electronc processor IL APS-K extenson cable Analog mult poston montorng for any desred postons Descrpton ID Mountng kt for APS-M1 AS-APS-M1-PGZN-plus Sensor APS-M1S When usng an APS system, for each grpper an attachment kt (AS-APS-M1), an APS-M1S sensor (ncl. 3 m cable) as well as an electroncs (APS-M1e) are requred. An extenson cable (APS-K) can be connected between the sensor and the electroncs as an opton. The max. cable length between the sensor and the electroncs s 10 m, between the electroncs and ther control unt (PLC) t s max. 1 m. Cylndrcal reed swtches End poston montorng can be mounted wth an attachment kt. Descrpton ID Attachment kt for proxmty swtch AS-RMS 80 PGN/PZN-plus 100/ Reed Swtches RMS 80-S-M Two sensors (closer/s) are requred for each unt and extenson cables are avalable as an opton. Ths attachment kt needs to be ordered optonally as an accessory. Two mountng kts are requred for each grpper. For sensor cables, note the mnmum permssble bendng rad. These are generally 35 mm. 51

52 JGZ 125 Unversal grpper Grppng force, O.D. grppng Fnger load Grppng force Grppng force, I.D. grppng Pont P - Fnger length M x max. 95 Nm M y max. 115 Nm M z max. 80 Nm F z max N Grppng force The specfed torques and forces are statc values, apply for each base jaw, and may occur smultaneously. M y may arse n addton to the moment generated by the grppng force tself. Pont P - Fnger length Techncal data Descrpton JGZ JGZ AS JGZ IS ID Stroke per jaw [mm] Closng / openng force [N] 3100/ /- -/4400 Mn. sprng force [N] Weght [kg] Recommended workpece weght [kg] Flud consumpton double stroke [cm³] Mn./max. operatng pressure [bar] 2/8 4/6.5 4/6.5 Nomnal operatng pressure [bar] Mn./max. ar purge pressure [bar] 0.5/1 0.5/1 0.5/1 Closng/openng tme [s] 0.2/ / /0.17 Closng- / openng tme wth sprng [s] Max. permssble fnger length [mm] Max. permssble mass per fnger [kg] Protecton class IP Mn./max. ambent temperature [ C] 5/90 5/90 5/90 Repeat accuracy [mm] Cleanroom class ISO

53 JGZ 125 Unversal grpper Man vew The drawng shows the grpper n the basc verson wth closed jaws, wthout dmensonal consderaton of the optons descrbed below. The SDV-P pressure mantenance valve can also be used for I.D. or O.D. grppng alternatvely or n addton to the sprng-loaded, mechancal grppng force mantenance devce (see catalog secton on accessores). A, a Man / drect connecton, grpper openng B, b Man / drect connecton, grpper closng S Ar purge connecton 1 Grpper connecton 2 Fnger connecton BN Bolt crcle GL Ft for centerng sleeves GM Ft for centerng pns HT Depth of the centerng sleeve hole n the counter part IT Thread below the cover for fastenng external attachments IK Sensor MMS 22.. IL Sensor IN... 53

54 JGZ 125 Unversal grpper Hose-free drect connecton M5 Grppng force mantenance devce AS / IS 3 Adapter 4 Grppers The drect connecton s used for supplyng compressed ar wthout hoses. Instead, the pressure medum s fed through bore-holes n the mountng plate. The mechancal grppng force mantenance devce ensures that a mnmum clampng force wll be appled even f there s a drop n pressure. Ths acts as closng force n the AS / S verson, and as openng force n the IS verson. Besdes ths, the grppng force mantenance devce can be used to ncrease the grppng force or for sngle actuated grppng. Sprng-loaded pressure pece SDV-P pressure mantenance valve For sprng-supported postonng of the workpece aganst a stop after the grpper has opened. Especally developed for loadng machnes. Descrpton ID Stroke Mn. force [mm] [N] Sprng-loaded pressure pece A-PZN-plus/DPZ-plus Grppers IT SDV-P pressure mantenance valve The SDV-P pressure mantenance valve ensures n emergency STOP stuatons that the pressure n the pston chamber of pneumatc grpper, swvel, lnear, and quck-change modules s temporarly mantaned. Descrpton ID Pressure mantenance valve SDV-P Pressure mantenance valve wth ar bleed screw SDV-P 04-E

55 JGZ 125 Unversal grpper BSWS jaw quck-change jaw systems ZBA-L-plus 125 ntermedate jaws 4 Grppers IT Customzed grpper fngers There are varous jaw quck-change systems avalable for the grpper. For detaled nformaton, please refer to the correspondng product. Descrpton ID Quck-change jaw system adapter BSWS-A BSWS-AR Quck-change jaw system base BSWS-B Jaw quck-change system BSWS-ABR-PGZN-plus BSWS-SBR-PGZN-plus Quck-change Jaw System reversed BSWS-UR Fnger connecton EP Included n the scope of delvery GL Ft for centerng sleeves HT Depth of the centerng sleeve hole n the counter part HK Not ncluded n the scope of delvery The optonal ZBA-L-plus ntermedate jaws allow the screw connecton dagram of the top jaws to be rotated by 90. Ths makes t easer to desgn and produce top jaws (partcularly for long versons) because no deep through-bores are requred. Descrpton ID Materal Fnger nterface Intermedate jaws ZBA-L-plus Alumnum PGN-plus 125 Scope of delvery 1 Only systems that are lsted n the table, can be used. 55

56 JGZ 125 Unversal grpper UZB 125 unversal ntermedate jaw Force-measurng jaws FMS-ZBA/ ZBP Grpper connecton 2 Fnger connecton EN Optonal rght or left connecton EQ Lockng GL Ft for centerng sleeves HT Depth of the centerng sleeve hole n the counter part The drawng shows the UZB unversal ntermedate jaw. The fully removable UZB-S slde (can also be ordered separately) allows for a quck jaw change. Descrpton ID Grd dmenson [mm] Unversal ntermedate jaw UZB UZB-S Fnger blanks ABR-PGZN-plus SBR-PGZN-plus Grpper connecton 2 Fnger connecton AQ Cable outlet GL Ft for centerng sleeves HT Depth of the centerng sleeve hole n the counter part IT Actve ntermedate jaws IK Passve ntermedate jaws Force-measurng jaws measure grppng forces, but can also determne workpece weghts or dmensonal devatons. There are actve and passve ntermedate jaws (FMS-ZBA or FMS-ZBP). At least one actve force-measurng jaw s requred per grpper, the rest can be passve. For each actve jaw, a FMS-A1 evaluaton unt and a FMS-A connecton cable are requred. Descrpton ID Often combned Actve ntermedate jaws FMS-ZBA Passve ntermedate jaws FMS-ZBP Connecton cables FMS-AK FMS-AK FMS-AK FMS-AK Evaluaton electroncs FMS-A Due to the screw length, the FMS system can not be used n combnaton wth the opton dust-proof (SD) of the grpper. Please note that the admssble force range of the force measurng jaw (see catalog chapter FMS) should not be exceeded for the chosen grpper verson. 56

57 JGZ 125 Unversal grpper Fnger blanks ABR- / SBR-PGZN-plus 125 TCU tolerance compensaton unt 2 Fnger connecton GL Ft for centerng sleeves The drawng shows the fnger blank whch can be reworked by the customer. Descrpton ID Materal Scope of delvery Fnger blanks ABR-PGZN-plus Alumnum 1 SBR-PGZN-plus MnCr5 1 IT montorng of lockng Grppers can be drectly mounted wthout an adapter plate. Tolerance compensaton unt and grpper have an dentcal screw connecton dagram. Therefore the tolerance compensaton unts can be assembled later. Please consder the addtonal assembly heght of the tolerance compensaton unt. For detals please refer to our catalog robot accessores. Descrpton ID Lockng Deflecton Often combned Compensaton unt TCU-Z MV yes ±1 /±1 /±1 TCU-Z OV no ±1 /±1 /±1 XY compensaton unt wth sprng return IT Montorng Grppers can be drectly mounted wthout an adapter plate. For detals see our catalog Grppng or Robot Accessores. Descrpton ID Compensaton XY Reset force [mm] [N] Compensaton unt AGE-F-XY ± 5 36 AGE-F-XY ± 5 55 Often combned AGE-F-XY ±

58 JGZ 125 Unversal grpper Inductve Proxmty Swtches AQ Cable outlet IT Sensor IN... IK Sensor IN..-SA Drectly mounted end poston montorng. Descrpton ID Often combned Inductve Proxmty Swtches IN 80-S-M IN 80-S-M INK 80-S Inductve proxmty swtch wth lateral outlet IN 80-S-M12-SA IN 80-S-M8-SA INK 80-S-SA Cable extenson KV BG12-SG12 3P-0030-PNP KV BG12-SG12 3P-0060-PNP KV BW08-SG08 3P-0030-PNP KV BW08-SG08 3P-0100-PNP KV BW08-SG08 3P-0200-PNP KV BW12-SG12 3P-0030-PNP KV BW12-SG12 3P-0100-PNP KV BW12-SG12 3P-0200-PNP clp for plug/socket CLI-M CLI-M Connecton cables KA BG08-L 3P-0300-PNP KA BG08-L 3P-0500-PNP KA BG12-L 3P-0500-PNP KA BW08-L 3P-0300-PNP KA BW08-L 3P-0500-PNP KA BW12-L 3P-0300-PNP KA BW12-L 3P-0500-PNP Sensor dstrbutor V2-M V2-M V4-M V4-M V8-M V8-M Two sensors (closer/s) are requred for each unt and extenson cables are avalable as an opton. For sensor cables, note the mnmum permssble bendng rad. These are generally 35 mm. 58

59 JGZ 125 Unversal grpper Flexble poston sensor Electronc magnetc swtches MMS IT FPS-S sensor Flexble poston montorng of up to fve postons. Descrpton Attachment kt for FPS AS-FPS-PGZN-plus 125-1/PZB Sensor FPS-S M Cable extenson KV BG08-SG08 3P KV BG08-SG08 3P Evaluaton electroncs FPS-F IK FPS-F5 evaluaton electronc When usng an FPS system, an FPS sensor (FPS-S) as well as an electronc processor (FPS-F5 / F5 T) are requred for each grpper as well as a mountng kt (AS), f lsted. Cable extensons (KV) are optonally avalable - see catalog chapter Accessores. ID End poston montorng for mountng n the C-slot. Descrpton ID Often combned Electronc magnetc swtches MMS MMS 22-S-M8-PNP MMSK 22-S-PNP MMS electronc magnetc swtches wth lateral outlet MMS 22-S-M8-PNP-SA MMSK 22-S-PNP-SA Reed Swtches RMS 22-S-M Cable extenson KV BW08-SG08 3P-0030-PNP KV BW08-SG08 3P-0100-PNP KV BW08-SG08 3P-0200-PNP clp for plug/socket CLI-M Connecton cables KA BG08-L 3P-0300-PNP KA BG08-L 3P-0500-PNP KA BW08-L 3P-0300-PNP KA BW08-L 3P-0500-PNP RSS Wreless sensor system RSS-T RSS-T2-US/CA Sensor dstrbutor V2-M V4-M V8-M Two sensors (closer/s) are requred for each unt and extenson cables are avalable as an opton. For sensor cables, note the mnmum permssble bendng rad. These are generally 35 mm. 59

60 JGZ 125 Unversal grpper Programmable magnetc swtch MMS 22-PI1 Programmable magnetc swtch MMS 22-PI2 AQ Cable outlet IT Sensor MMS 22 PI1-... IK Sensor MMS 22..-PI1-...-SA Poston montorng wth one programmable poston per sensor and electroncs ntegrated n the sensor. Can be programmed usng MT magnetc teachng tool (ncluded n scope of delvery) or ST plug teachng tool (optonal). End poston montorng s mounted n the C-slot. If the ST plug teachng tools are lsted n the table provded, teachng s only possble wth the ST teachng tools. Descrpton ID Often combned Programmable magnetc swtch MMS 22-PI1 MMS 22-PI1-S-M8-PNP MMSK 22-PI1-S-PNP Programmable magnetc swtch MMS 22-PI1 wth lateral connecton MMS 22-PI1-S-M8-PNP-SA MMSK 22-PI1-S-PNP-SA Programmable magnetc swtch MMS 22-PI1 wth stanless steel housng MMS 22-PI1-S-M8-PNP-HD MMSK 22-PI1-S-PNP-HD AQ Cable outlet IT MMS PI2-... sensor Poston montorng wth two programmable postons per sensor and electroncs bult nto the sensor. Can be programmed usng MT magnetc teachng tool (ncluded n the scope of delvery) or ST plug teachng tool (optonal). End poston montorng for mountng n the C-slot. If the ST plug teachng tools are lsted n the table provded, teachng s only possble wth the ST teachng tools. Descrpton ID Often combned Programmable magnetc swtch MMS 22-PI2 MMS 22-PI2-S-M8-PNP MMSK 22-PI2-S-PNP Programmable magnetc swtch MMS 22-PI2 wth stanless steel housng MMS 22-PI2-S-M8-PNP-HD MMSK 22-PI2-S-PNP-HD Per unt one sensor (closer/s) s requred, optonally a cable extenson. For sensor cables, note the mnmum permssble bendng rad. These are generally 35 mm. Two sensors (closer/s) are requred for each unt and extenson cables are avalable as an opton. For sensor cables, note the mnmum permssble bendng rad. These are generally 35 mm. 60

61 JGZ 125 Unversal grpper Programmable magnetc swtches MMS-P APS-Z80 analog poston sensor GN Lmt stop for sensor Poston montorng wth two programmable postons per sensor. End poston montorng for mountng n the C-slot. Descrpton ID Often combned Programmable magnetc swtches MMS-P MMSK-P 22-S-PNP MMS-P 22-S-M8-PNP clp for plug/socket CLI-M Connecton cables KA BG08-L 4P KA BG08-L 4P KA BW08-L 4P KA BW08-L 4P Sensor dstrbutor V2-M8-4P-2XM8-3P No-contact measurng, analog mult-poston montorng for any number of postons. Descrpton ID Often combned Mountng kt for APS-Z80 AS-APS-Z80-PGZN-plus Sensor APS-Z80-K APS-Z80-M When usng an APS system, one attachment kt (AS-APS-Z80) and one APS-Z80 sensor are requred per grpper. Per unt one sensor (closer/s) s requred, optonally a cable extenson. For sensor cables, note the mnmum permssble bendng rad. These are generally 35 mm. 61

62 JGZ 125 Unversal grpper APS-M1 analog poston sensor Cylndrcal reed swtches IT APS-M1S sensor IK APS-M1E electronc processor IL APS-K extenson cable Analog mult poston montorng for any desred postons Descrpton Mountng kt for APS-M1 AS-APS-M1-PGZN-plus Sensor APS-M1S ID When usng an APS system, for each grpper an attachment kt (AS-APS-M1), an APS-M1S sensor (ncl. 3 m cable) as well as an electroncs (APS-M1e) are requred. An extenson cable (APS-K) can be connected between the sensor and the electroncs as an opton. The max. cable length between the sensor and the electroncs s 10 m, between the electroncs and ther control unt (PLC) t s max. 1 m. End poston montorng can be mounted wth an attachment kt. Descrpton ID Attachment kt for proxmty swtch AS-RMS 80 PGN/PZN-plus 100/ Reed Swtches RMS 80-S-M Two sensors (closer/s) are requred for each unt and extenson cables are avalable as an opton. Ths attachment kt needs to be ordered optonally as an accessory. Two mountng kts are requred for each grpper. For sensor cables, note the mnmum permssble bendng rad. These are generally 35 mm. 62

63 JGZ 125 Unversal grpper 63

64 JGZ 160 Unversal grpper Grppng force, O.D. grppng Fnger load Grppng force Grppng force, I.D. grppng Pont P - Fnger length M x max. 136 Nm M y max. 145 Nm M z max. 105 Nm F z max N Grppng force The specfed torques and forces are statc values, apply for each base jaw, and may occur smultaneously. M y may arse n addton to the moment generated by the grppng force tself. Pont P - Fnger length Techncal data Descrpton JGZ JGZ AS JGZ IS ID Stroke per jaw [mm] Closng / openng force [N] 6000/ /- -/8480 Mn. sprng force [N] Weght [kg] Recommended workpece weght [kg] Flud consumpton double stroke [cm³] Mn./max. operatng pressure [bar] 2/8 4/6.5 4/6.5 Nomnal operatng pressure [bar] Mn./max. ar purge pressure [bar] 0.5/1 0.5/1 0.5/1 Closng/openng tme [s] 0.5/ / /0.4 Closng- / openng tme wth sprng [s] Max. permssble fnger length [mm] Max. permssble mass per fnger [kg] Protecton class IP Mn./max. ambent temperature [ C] 5/90 5/90 5/90 Repeat accuracy [mm] Cleanroom class ISO

65 JGZ 160 Unversal grpper Man vew The drawng shows the grpper n the basc verson wth closed jaws, wthout dmensonal consderaton of the optons descrbed below. The SDV-P pressure mantenance valve can also be used for I.D. or O.D. grppng alternatvely or n addton to the sprng-loaded, mechancal grppng force mantenance devce (see catalog secton on accessores). A, a Man / drect connecton, grpper openng B, b Man / drect connecton, grpper closng S Ar purge connecton 1 Grpper connecton 2 Fnger connecton BN Bolt crcle GL Ft for centerng sleeves GM Ft for centerng pns HT Depth of the centerng sleeve hole n the counter part IT Thread below the cover for fastenng external attachments IK Sensor MMS 22.. IL Sensor IN... 65

66 JGZ 160 Unversal grpper Hose-free drect connecton M4 Grppng force mantenance devce AS / IS 3 Adapter 4 Grppers The drect connecton s used for supplyng compressed ar wthout hoses. Instead, the pressure medum s fed through bore-holes n the mountng plate. The mechancal grppng force mantenance devce ensures that a mnmum clampng force wll be appled even f there s a drop n pressure. Ths acts as closng force n the AS / S verson, and as openng force n the IS verson. Besdes ths, the grppng force mantenance devce can be used to ncrease the grppng force or for sngle actuated grppng. Sprng-loaded pressure pece SDV-P pressure mantenance valve For sprng-supported postonng of the workpece aganst a stop after the grpper has opened. Especally developed for loadng machnes. Descrpton ID Stroke Mn. force [mm] [N] Sprng-loaded pressure pece A-PZN-plus/DPZ-plus Grppers IT SDV-P pressure mantenance valve The SDV-P pressure mantenance valve ensures n emergency STOP stuatons that the pressure n the pston chamber of pneumatc grpper, swvel, lnear, and quck-change modules s temporarly mantaned. Descrpton ID Pressure mantenance valve SDV-P Pressure mantenance valve wth ar bleed screw SDV-P 04-E

67 JGZ 160 Unversal grpper BSWS jaw quck-change jaw systems ZBA-L-plus 160 ntermedate jaws 4 Grppers IT Customzed grpper fngers There are varous jaw quck-change systems avalable for the grpper. For detaled nformaton, please refer to the correspondng product. Descrpton ID Quck-change jaw system adapter BSWS-A BSWS-AR Quck-change jaw system base BSWS-B Jaw quck-change system BSWS-ABR-PGZN-plus BSWS-SBR-PGZN-plus Quck-change Jaw System reversed BSWS-UR Fnger connecton EP Included n the scope of delvery GL Ft for centerng sleeves HT Depth of the centerng sleeve hole n the counter part HK Not ncluded n the scope of delvery The optonal ZBA-L-plus ntermedate jaws allow the screw connecton dagram of the top jaws to be rotated by 90. Ths makes t easer to desgn and produce top jaws (partcularly for long versons) because no deep through-bores are requred. Descrpton ID Materal Fnger nterface Intermedate jaws ZBA-L-plus Alumnum PGN-plus 160 Scope of delvery 1 Only systems that are lsted n the table, can be used. 67

68 JGZ 160 Unversal grpper UZB 160 unversal ntermedate jaw Force-measurng jaws FMS-ZBA/ ZBP Grpper connecton 2 Fnger connecton EN Optonal rght or left connecton EQ Lockng GL Ft for centerng sleeves HT Depth of the centerng sleeve hole n the counter part The drawng shows the UZB unversal ntermedate jaw. The fully removable UZB-S slde (can also be ordered separately) allows for a quck jaw change. Descrpton ID Grd dmenson [mm] Unversal ntermedate jaw UZB UZB-S Fnger blanks ABR-PGZN-plus SBR-PGZN-plus Grpper connecton 2 Fnger connecton AQ Cable outlet GL Ft for centerng sleeves HT Depth of the centerng sleeve hole n the counter part IT Actve ntermedate jaws IK Passve ntermedate jaws Force-measurng jaws measure grppng forces, but can also determne workpece weghts or dmensonal devatons. There are actve and passve ntermedate jaws (FMS-ZBA or FMS-ZBP). At least one actve force-measurng jaw s requred per grpper, the rest can be passve. For each actve jaw, a FMS-A1 evaluaton unt and a FMS-A connecton cable are requred. Descrpton ID Often combned Actve ntermedate jaws FMS-ZBA Passve ntermedate jaws FMS-ZBP Connecton cables FMS-AK FMS-AK FMS-AK FMS-AK Evaluaton electroncs FMS-A Due to the screw length, the FMS system can not be used n combnaton wth the opton dust-proof (SD) of the grpper. Please note that the admssble force range of the force measurng jaw (see catalog chapter FMS) should not be exceeded for the chosen grpper verson. 68

69 JGZ 160 Unversal grpper Fnger blanks ABR- / SBR-PGZN-plus 160 TCU tolerance compensaton unt 2 Fnger connecton GL Ft for centerng sleeves The drawng shows the fnger blank whch can be reworked by the customer. Descrpton ID Materal Scope of delvery Fnger blanks ABR-PGZN-plus Alumnum 1 SBR-PGZN-plus MnCr5 1 IT montorng of lockng Grppers can be drectly mounted wthout an adapter plate. Tolerance compensaton unt and grpper have an dentcal screw connecton dagram. Therefore the tolerance compensaton unts can be assembled later. Please consder the addtonal assembly heght of the tolerance compensaton unt. For detals please refer to our catalog robot accessores. Descrpton ID Lockng Deflecton Often combned Compensaton unt TCU-Z MV yes ±1 /±1 /±1 TCU-Z OV no ±1 /±1 /±1 69

70 JGZ 160 Unversal grpper Inductve Proxmty Swtches Flexble poston sensor AQ Cable outlet IT Sensor IN... Drectly mounted end poston montorng. IK Sensor IN..-SA Descrpton ID Often combned Inductve Proxmty Swtches IN 80-S-M IN 80-S-M INK 80-S Inductve proxmty swtch wth lateral outlet IN 80-S-M12-SA INK 80-S-SA Cable extenson KV BG12-SG12 3P-0030-PNP KV BG12-SG12 3P-0060-PNP KV BW08-SG08 3P-0030-PNP KV BW08-SG08 3P-0100-PNP KV BW08-SG08 3P-0200-PNP KV BW12-SG12 3P-0030-PNP KV BW12-SG12 3P-0100-PNP KV BW12-SG12 3P-0200-PNP clp for plug/socket CLI-M CLI-M Connecton cables KA BG08-L 3P-0300-PNP KA BG08-L 3P-0500-PNP KA BG12-L 3P-0500-PNP KA BW08-L 3P-0300-PNP KA BW08-L 3P-0500-PNP KA BW12-L 3P-0300-PNP KA BW12-L 3P-0500-PNP Sensor dstrbutor V2-M V2-M V4-M V4-M V8-M V8-M IT FPS-S sensor Flexble poston montorng of up to fve postons. Descrpton ID Attachment kt for FPS AS-FPS-PGZN-plus Sensor FPS-S M Cable extenson KV BG08-SG08 3P KV BG08-SG08 3P Evaluaton electroncs FPS-F IK FPS-F5 evaluaton electronc When usng an FPS system, an FPS sensor (FPS-S) as well as an electronc processor (FPS-F5 / F5 T) are requred for each grpper as well as a mountng kt (AS), f lsted. Cable extensons (KV) are optonally avalable - see catalog chapter Accessores. Two sensors (closer/s) are requred for each unt and extenson cables are avalable as an opton. For sensor cables, note the mnmum permssble bendng rad. These are generally 35 mm. 70

71 JGZ 160 Unversal grpper Electronc magnetc swtches MMS Programmable magnetc swtch MMS 22-PI1 End poston montorng for mountng n the C-slot. Descrpton ID Often combned Electronc magnetc swtches MMS MMS 22-S-M8-PNP MMSK 22-S-PNP MMS electronc magnetc swtches wth lateral outlet MMS 22-S-M8-PNP-SA MMSK 22-S-PNP-SA Reed Swtches RMS 22-S-M Cable extenson KV BW08-SG08 3P-0030-PNP KV BW08-SG08 3P-0100-PNP KV BW08-SG08 3P-0200-PNP clp for plug/socket CLI-M Connecton cables KA BG08-L 3P-0300-PNP KA BG08-L 3P-0500-PNP KA BW08-L 3P-0300-PNP KA BW08-L 3P-0500-PNP RSS Wreless sensor system RSS-T RSS-T2-US/CA Sensor dstrbutor V2-M V4-M V8-M AQ Cable outlet IT Sensor MMS 22 PI1-... IK Sensor MMS 22..-PI1-...-SA Poston montorng wth one programmable poston per sensor and electroncs ntegrated n the sensor. Can be programmed usng MT magnetc teachng tool (ncluded n scope of delvery) or ST plug teachng tool (optonal). End poston montorng s mounted n the C-slot. If the ST plug teachng tools are lsted n the table provded, teachng s only possble wth the ST teachng tools. Descrpton ID Often combned Plug teachng tool ST-MMS 22-PI1-PNP Programmable magnetc swtch MMS 22-PI1 MMS 22-PI1-S-M8-PNP MMSK 22-PI1-S-PNP Programmable magnetc swtch MMS 22-PI1 wth lateral connecton MMS 22-PI1-S-M8-PNP-SA MMSK 22-PI1-S-PNP-SA Programmable magnetc swtch MMS 22-PI1 wth stanless steel housng MMS 22-PI1-S-M8-PNP-HD MMSK 22-PI1-S-PNP-HD Two sensors (closer/s) are requred for each unt and extenson cables are avalable as an opton. For sensor cables, note the mnmum permssble bendng rad. These are generally 35 mm. Two sensors (closer/s) are requred for each unt and extenson cables are avalable as an opton. For sensor cables, note the mnmum permssble bendng rad. These are generally 35 mm. 71

72 JGZ 160 Unversal grpper Programmable magnetc swtches MMS-P APS-Z80 analog poston sensor GN Lmt stop for sensor Poston montorng wth two programmable postons per sensor. End poston montorng for mountng n the C-slot. Descrpton ID Often combned Programmable magnetc swtches MMS-P MMSK-P 22-S-PNP MMS-P 22-S-M8-PNP clp for plug/socket CLI-M Connecton cables KA BG08-L 4P KA BG08-L 4P KA BW08-L 4P KA BW08-L 4P Sensor dstrbutor V2-M8-4P-2XM8-3P No-contact measurng, analog mult-poston montorng for any number of postons. Descrpton ID Often combned Mountng kt for APS-Z80 AS-APS-Z80-PGZN-plus 160-1/200-2/ Sensor APS-Z80-K APS-Z80-M When usng an APS system, one attachment kt (AS-APS-Z80) and one APS-Z80 sensor are requred per grpper. Per unt one sensor (closer/s) s requred, optonally a cable extenson. For sensor cables, note the mnmum permssble bendng rad. These are generally 35 mm. 72

73 JGZ 160 Unversal grpper APS-M1 analog poston sensor Cylndrcal reed swtches IT APS-M1S sensor IK APS-M1E electronc processor IL APS-K extenson cable Analog mult poston montorng for any desred postons Descrpton Mountng kt for APS-M1 AS-APS-M1-PGZN-plus 160-1/ Sensor APS-M1S When usng an APS system, for each grpper an attachment kt (AS-APS-M1), an APS-M1S sensor (ncl. 3 m cable) as well as an electroncs (APS-M1e) are requred. An extenson cable (APS-K) can be connected between the sensor and the electroncs as an opton. The max. cable length between the sensor and the electroncs s 10 m, between the electroncs and ther control unt (PLC) t s max. 1 m. ID End poston montorng can be mounted wth an attachment kt. Descrpton ID Attachment kt for proxmty swtch AS-RMS 80 PGN/PZN-plus Reed Swtches RMS 80-S-M Two sensors (closer/s) are requred for each unt and extenson cables are avalable as an opton. Ths attachment kt needs to be ordered optonally as an accessory. Two mountng kts are requred for each grpper. For sensor cables, note the mnmum permssble bendng rad. These are generally 35 mm. 73

74 SCHUNK GmbH & Co. KG Spann- und Greftechnk Bahnhofstr D Lauffen/Neckar Tel Fax Folgen Se uns Jens Lehmann, German goalkeeper legend, SCHUNK brand ambassador snce 2012 for safe, precse grppng and holdng. schunk.com/lehmann SCHUNK GmbH & Co. KG

Gripping force, O.D. gripping. Gripping force, I.D. gripping

Gripping force, O.D. gripping. Gripping force, I.D. gripping Grppng force, O.D. grppng Fnger load Grppng force Grppng force, I.D. grppng Grppng force Fnger length M x max. 80 Nm M y max. 115 Nm M z max. 70 Nm F z max. 2000 N Fnger length The ndcated moments and

More information

Product Information. Universal gripper PGN-plus

Product Information. Universal gripper PGN-plus Product Informaton Unversal grpper PGN-plus PGN-plus Unversal grpper Relable. Robust. Flexble. PGN-plus unversal grpper Unversal 2-Fnger Parallel Grpper wth large grppng force and hgh maxmum moments due

More information

Product Information. Gripper for small components EGP

Product Information. Gripper for small components EGP Product Informaton EGP EGP Hgh Performance Densty. Fast. Compact. EGP grpper for small components Electrc 2-fnger parallel grpper wth smooth-runnng base jaws guded on roller bearngs Feld of applcaton Grppng

More information

Product Information. Universal gripper PGN-plus-E

Product Information. Universal gripper PGN-plus-E Product Informaton PGN-plus-E PGN-plus-E Relable. Robust. Flexble. PGN-plus-E unversal grpper Unversal, Electrc 2-Fnger Parallel Grpper wth permanent lubrcaton, large grppng force and hgh maxmum moments

More information

Product Information. Gripper for small components EGP

Product Information. Gripper for small components EGP Product Informaton EGP EGP Hgh Performance Densty. Fast. Compact. EGP grpper for small components Electrc 2-fnger parallel grpper wth smooth-runnng base jaws guded on roller bearngs Feld of applcaton Grppng

More information

Product Information. Long-stroke gripper EGA

Product Information. Long-stroke gripper EGA Product Informaton EGA EGA Flexble. Modular. Robust. EGA long-stroke grpper Electrc 2-fnger parallel grpper wth lghtweght profle ral gude and adaptable servo- motor Feld of applcaton Optmal standard soluton

More information

Product Information. Gripper for small components EGP 50

Product Information. Gripper for small components EGP 50 Product Informaton EGP 50 EGP Hgh Performance Densty. Fast. Compact. EGP grpper for small components Electrc 2-fnger parallel grpper wth smooth-runnng base jaws guded on roller bearngs Feld of applcaton

More information

Product Information. Jaw quick-change system BSWS-PGZN-plus

Product Information. Jaw quick-change system BSWS-PGZN-plus Product Informaton BSWS-PGZN-plus BSWS-PGZN-plus Productve. Flexble. Cost-effectve. BSWS jaw quck-change system The BSWS jaw quck-change system allows top jaws to be changed on the grpper manually and

More information

Product Information. Long-stroke gripper PEH

Product Information. Long-stroke gripper PEH Product Informaton PEH PEH Flexble. Hgh Performance Densty. Bus capable. PEH long-stroke grpper Servo-electrc 2-fnger parallel grpper wth long jaw stroke for large parts and dverse parts spectrum Feld

More information

Strain Gauge Measuring Amplifier BA 660

Strain Gauge Measuring Amplifier BA 660 Stran Gauge Measurng Amplfer BA 660 Orgnal of the Manual BA660 / IP20 BA660 / IP66 Table of Contents 1. Safety precautons...2 1.1. Feld of applcaton...2 1.2. Installaton...2 1.3. Mantenance...2 2. Functon...2

More information

MULTIPOLE CONNECTORS SQUICH CN NEW SQUICH. Connections without tools reduced space SQUICH A TIMESAVER

MULTIPOLE CONNECTORS SQUICH CN NEW SQUICH. Connections without tools reduced space SQUICH A TIMESAVER SCREW CONNECTION ULTIPOLE CONNECTORS SQUICH CN SQUICH SQUICH Connectons wthout tools reduced space A TIESAVER SQUICH ULTIPOLE CONNECTORS SQUICH CN SQUICH seres Connectons wthout tools To mprove hgh performance

More information

Sensors for Motion and Position Measurement

Sensors for Motion and Position Measurement Sensors for Moton and Poston Measurement Introducton An ntegrated manufacturng envronment conssts of 5 elements:- - Machne tools - Inspecton devces - Materal handlng devces - Packagng machnes - Area where

More information

PRO- CRIMPER* III Hand Crimping

PRO- CRIMPER* III Hand Crimping PRO- CRIMPER* III Hand Crmpng Instructon Sheet Tool Assembly 91338-1 408-8377 wth De Assembly 91338-2 22 JUL 09 PROPER USE GUIDELINES Cumulatve Trauma Dsorders can result from the prolonged use of manually

More information

Dynamic Optimization. Assignment 1. Sasanka Nagavalli January 29, 2013 Robotics Institute Carnegie Mellon University

Dynamic Optimization. Assignment 1. Sasanka Nagavalli January 29, 2013 Robotics Institute Carnegie Mellon University Dynamc Optmzaton Assgnment 1 Sasanka Nagavall snagaval@andrew.cmu.edu 16-745 January 29, 213 Robotcs Insttute Carnege Mellon Unversty Table of Contents 1. Problem and Approach... 1 2. Optmzaton wthout

More information

PRO- CRIMPER III Hand Crimping Tool Assembly DESCRIPTION (Figures 1 and 2)

PRO- CRIMPER III Hand Crimping Tool Assembly DESCRIPTION (Figures 1 and 2) PRO- CRIMPER* III Hand Crmpng Instructon Sheet Tool Assembly 58495-1 408-9819 Wth De Assembly 58495-2 22 JUL 09 PROPER USE GUIDELINES Cumulatve Trauma Dsorders can result from the prolonged use of manually

More information

Pneumatic Power Bench Assembly

Pneumatic Power Bench Assembly Pneumatc Power Bench Assembly 58338-1 Instructon Sheet 408-9393 09 AUG 11 Fgure 1 1. INTRODUCTION Pneumatc Power Bench Assembly 58338-1 s a pneumatc power unt desgned to accept a varety of nterchangeable

More information

Instruction Sheet AMPMODU* MTE CONNECTORS Mar 11 Rev A

Instruction Sheet AMPMODU* MTE CONNECTORS Mar 11 Rev A Instructon Sheet AMPMODU* MTE CONNECTORS 408-6919 10 Mar 11 PROPER USE GUIDELINES Cumulatve Trauma Dsorders can result from the prolonged use of manually powered hand tools. Hand tools are ntended for

More information

1. REVIEW 2. DELIVERY SET

1. REVIEW 2. DELIVERY SET power status ON steps DIP test reset ON DIP off modes lght sensor / led sensor speed on sensor 2 speed off on/off delay pause to off REVIEW LED lghtng devce s desgned for automatc lghtng of starway steps

More information

onlinecomponents.com

onlinecomponents.com PRO- CRIMPER* III Hand Crmpng Instructon Sheet Tool Assembly 58535-1 wth 408-4021 De Assembly 58535-2 29 JUL 09 PROPER USE GUIDELINES Cumulatve Trauma Dsorders can result from the prolonged use of manually

More information

PRO-CRIMPER* III Hand Crimping Tool Assembly with Die Assembly

PRO-CRIMPER* III Hand Crimping Tool Assembly with Die Assembly PRO-CRIMPER* III Hand Crmpng Tool Assembly 90548-1 wth De Assembly 90548-2 Instructon Sheet 408-9885 02 NOV 12 PROPER USE GUIDELINES Cumulatve Trauma Dsorders can result from the prolonged use of manually

More information

AFV-P 2U/4U. AC + DC Power Solutions. series. Transient Generation for Disturbance Tests. only. High Performance Programmable AC Power Source

AFV-P 2U/4U. AC + DC Power Solutions. series. Transient Generation for Disturbance Tests. only. High Performance Programmable AC Power Source AFV-P seres Hgh Performance Programmable AC Power Source only 2U/4U Intutve Touch Screen HMI Output Frequency up to 15-1000Hz Power Lne Smulatons: Step & Ramp Features Fast Response Tme: 300μs AC Source

More information

PRO- CRIMPER* III Hand

PRO- CRIMPER* III Hand PRO- CRIMPER* III Hand Instructon Sheet Crmpng Tool Assembly 90684-1 408-9934 wth De Assembly 90684-2 09 OCT 09 PROPER USE GUIDELINES Cumulatve Trauma Dsorders can result from the prolonged use of manually

More information

PRO- CRIMPER* III Hand Crimping

PRO- CRIMPER* III Hand Crimping PRO- CRIMPER* III Hand Crmpng Instructon Sheet Tool Assembly 58641-1 wth 408-4379 De Assembly 58641-2 18 JUN 09 PROPER USE GUIDELINES Cumulatve Trauma Dsorders can result from the prolonged use of manually

More information

PRO- CRIMPER* III Hand

PRO- CRIMPER* III Hand PRO- CRIMPER* III Hand Instructon Sheet Crmpng Tool Assembly 90759-1 408-9962 wth De Assembly 90759-2 03 MAY 11 PROPER USE GUIDELINES Cumulatve Trauma Dsorders can result from the prolonged use of manually

More information

PRO- CRIMPER* III Hand Crimping

PRO- CRIMPER* III Hand Crimping PRO- CRIMPER* III Hand Crmpng Instructon Sheet Tool 58448-2 408-9357 Wth De 58448-3 10 Mar 11 PROPER USE GUIDELINES Cumulatve Trauma Dsorders can result from the prolonged use of manually powered hand

More information

PRO- CRIMPER III Hand Crimping Tool Assembly INSTALLATION AND REMOVAL OF DIE SET AND LOCATOR ASSEMBLY (Figure 2)

PRO- CRIMPER III Hand Crimping Tool Assembly INSTALLATION AND REMOVAL OF DIE SET AND LOCATOR ASSEMBLY (Figure 2) PRO- CRIMPER* III Hand Crmpng Instructon Sheet Tool Assembly 90547-1 wth 408-9884 De Assembly 90547-2 02 NOV 09 PROPER USE GUIDELINES Cumulatve Trauma Dsorders can result from the prolonged use of manually

More information

PRO-CRIMPER* III Hand Crimping Tool Assembly with Die AssemblY

PRO-CRIMPER* III Hand Crimping Tool Assembly with Die AssemblY PRO-CRIMPER* III Hand Crmpng Tool Assembly 90758-1 wth De AssemblY 90758-2 Instructon Sheet 408-9938 01 NOV 11 PROPER USE GUIDELINES Cumulatve Trauma Dsorders can result from the prolonged use of manually

More information

STRATO-THERM* Terminal and Splice Hand Crimping Tools and 59461

STRATO-THERM* Terminal and Splice Hand Crimping Tools and 59461 STRATO-THERM* Termnal and Splce Hand Crmpng Tools 59294 and 59461 Instructon Sheet 408-1259 17 AUG 10 PROPER USE GUIDELINES Cumulatve Trauma Dsorders can result from the prolonged use of manually powered

More information

PRO- CRIMPER* III Hand

PRO- CRIMPER* III Hand PRO- CRIMPER* III Hand Instructon Sheet Crmpng Tool Assembly 58529-1 408-9999 wth De Assembly 58529-2 11 AUG 14 PROPER USE GUIDELINES Cumulatve Trauma Dsorders can result from the prolonged use of manually

More information

PRO-CRIMPER* III Hand Tool Assembly with Die Assembly

PRO-CRIMPER* III Hand Tool Assembly with Die Assembly PRO-CRIMPER* III Hand Tool Assembly 2063778-1 wth De Assembly 2063778-2 Instructon Sheet 408-10290 02 FEB 12 PROPER USE GUIDELINES Cumulatve Trauma Dsorders can result from the prolonged use of manually

More information

PRO-CRIMPER* III Hand Crimping Tool Assembly and Die Assemblies [ ]

PRO-CRIMPER* III Hand Crimping Tool Assembly and Die Assemblies [ ] PRO-CRIMPER* III Hand Crmpng Tool Assembly 58546-1 and De Assembles 58545-[ ] Instructon Sheet 408-8678 13 MAR 14 PROPER USE GUIDELINES Cumulatve Trauma Dsorders can result from the prolonged use of manually

More information

Bourdon tube safety pressure gauges EN 837-1

Bourdon tube safety pressure gauges EN 837-1 safety pressure gauges EN 837-1 Safety pressure gauge S3 as per EN 837-1/9.7.2 Measurng system fully welded to housng Tghtness-tested wth helum DNV- and GOSSTANDART-certfed A Page 476 Applcaton For corrosve

More information

Uncertainty in measurements of power and energy on power networks

Uncertainty in measurements of power and energy on power networks Uncertanty n measurements of power and energy on power networks E. Manov, N. Kolev Department of Measurement and Instrumentaton, Techncal Unversty Sofa, bul. Klment Ohrdsk No8, bl., 000 Sofa, Bulgara Tel./fax:

More information

Locator Pin Indexing Pin. Wire Size Marking CAUTION NOTE TOOLING ASSISTANCE CENTER PRODUCT INFORMATION

Locator Pin Indexing Pin. Wire Size Marking CAUTION NOTE TOOLING ASSISTANCE CENTER PRODUCT INFORMATION ROTA-CRIMP* Crmpng Tool Instructon Sheet 408-2681 68321-1 13 APR 12 Statonary De (Nest) Anvl De Hold-Down Devce and Contact Locator Front of Tool Locator Pn Indexng Pn Wre Sze Markng The hold-down devce

More information

MTBF PREDICTION REPORT

MTBF PREDICTION REPORT MTBF PREDICTION REPORT PRODUCT NAME: BLE112-A-V2 Issued date: 01-23-2015 Rev:1.0 Copyrght@2015 Bluegga Technologes. All rghts reserved. 1 MTBF PREDICTION REPORT... 1 PRODUCT NAME: BLE112-A-V2... 1 1.0

More information

100 mm. 200 mm. 300 mm. 500 mm. Wood (rough) Cardboard Black DBT DBT DBT DBT DBT - 1 K DBT K CONNECTION DIAGRAMS.

100 mm. 200 mm. 300 mm. 500 mm. Wood (rough) Cardboard Black DBT DBT DBT DBT DBT - 1 K DBT K CONNECTION DIAGRAMS. DIFFUSED BEAM SENSOR Ths devce consst of a transmtter and a recever together. Ths look alke Inductve Proxmty Sensor and hence also known as IR Proxmty Sensor. The emtter emts Infra red rays whch are reflected

More information

Unit 1. Current and Voltage U 1 VOLTAGE AND CURRENT. Circuit Basics KVL, KCL, Ohm's Law LED Outputs Buttons/Switch Inputs. Current / Voltage Analogy

Unit 1. Current and Voltage U 1 VOLTAGE AND CURRENT. Circuit Basics KVL, KCL, Ohm's Law LED Outputs Buttons/Switch Inputs. Current / Voltage Analogy ..2 nt Crcut Bascs KVL, KCL, Ohm's Law LED Outputs Buttons/Swtch Inputs VOLTAGE AND CRRENT..4 Current and Voltage Current / Voltage Analogy Charge s measured n unts of Coulombs Current Amount of charge

More information

TECHNICAL NOTE TERMINATION FOR POINT- TO-POINT SYSTEMS TN TERMINATON FOR POINT-TO-POINT SYSTEMS. Zo = L C. ω - angular frequency = 2πf

TECHNICAL NOTE TERMINATION FOR POINT- TO-POINT SYSTEMS TN TERMINATON FOR POINT-TO-POINT SYSTEMS. Zo = L C. ω - angular frequency = 2πf TECHNICAL NOTE TERMINATION FOR POINT- TO-POINT SYSTEMS INTRODUCTION Because dgtal sgnal rates n computng systems are ncreasng at an astonshng rate, sgnal ntegrty ssues have become far more mportant to

More information

SDE PEW- 12 Hand Tool

SDE PEW- 12 Hand Tool SDE PEW- 12 Hand Tool Instructon Sheet Assembly 2063956-1 wth 408-10370 De Assembly 2063956-2 07 OCT 10 PROPER USE GUIDELINES Cumulatve Trauma Dsorders can result from the prolonged use of manually powered

More information

PRO-CRIMPER* III Hand. with Die Assembly OCT 11 Rev C. Pivot Pin. Die Assembly Moving Jaw CONTACT FAMILY SIZE (AWG)

PRO-CRIMPER* III Hand. with Die Assembly OCT 11 Rev C. Pivot Pin. Die Assembly Moving Jaw CONTACT FAMILY SIZE (AWG) PRO-CRIMPER* III Hand Instructon Sheet Crmpng Tool Assembly 58514-1 408-9973 wth De Assembly 58514-2 12 OCT 11 PROPER USE GUIDELINES Cumulatve Trauma Dsorders can result from the prolonged use of manually

More information

Instruction Sheet SDE- SA Hand Tool Assembly with Die Assembly

Instruction Sheet SDE- SA Hand Tool Assembly with Die Assembly Instructon Sheet 408-10002 wth De Assembly 1752938-2 06 APR 10 PROPER USE GUIDELINES Cumulatve Trauma Dsorders can result from the prolonged use of manually powered hand tools. Hand tools are ntended for

More information

Parking barrier Parc 200 / Parc 200 speed

Parking barrier Parc 200 / Parc 200 speed GB Operatng nstructons Last updated: 01.2014 Parkng barrer Parc 200 / Parc 200 speed 1. Meanng of symbols 2. Table of contents Advce Cauton! Danger of personal njury! The followng safety advce must be

More information

Shunt Active Filters (SAF)

Shunt Active Filters (SAF) EN-TH05-/004 Martt Tuomanen (9) Shunt Actve Flters (SAF) Operaton prncple of a Shunt Actve Flter. Non-lnear loads lke Varable Speed Drves, Unnterrupted Power Supples and all knd of rectfers draw a non-snusodal

More information

220 A MANUAL DE INSTRUCCIONES INSTRUCTIONS MANUAL TIRE CHANGING MACHINE DESMONTA-NEUMATICOS

220 A MANUAL DE INSTRUCCIONES INSTRUCTIONS MANUAL TIRE CHANGING MACHINE DESMONTA-NEUMATICOS TRE CHANGNG MACHNE DESMONTA-NEUMATCOS 220 A CE EN -ES D NSTRUCTONS MANUAL MANUAL DE NSTRUCCONES COD.103931 Rev.0 N.103944 Rev. 0 220 A 01110 CLAMP CONTROL ROD BUSHNG 01363 30X17X0,3 WASHER 01368 1510 1/8

More information

AMPINNERGY* Modular Wiring System 25 JUL 11 Rev G

AMPINNERGY* Modular Wiring System 25 JUL 11 Rev G Applcaton Specfcaton 114-6039 AMPINNERGY* Modular Wrng System 25 JUL 11 Rev G All numercal values are n metrc unts [wth U.S. customary unts n brackets]. Dmensons are n mllmeters [and nches]. Unless otherwse

More information

Hand Crimping Tool (For Insulated Heat Shrink Splices)

Hand Crimping Tool (For Insulated Heat Shrink Splices) Hand Crmpng Tool 607949-1 (For Insulated Heat Shrnk Splces) Instructon Sheet 408-4087 23 JAN 12 PROPER USE GUIDELINES Cumulatve Trauma Dsorders can result from the prolonged use of manually powered hand

More information

Insertion/Extraction Tool and Replacement Tip Kits [ ]

Insertion/Extraction Tool and Replacement Tip Kits [ ] Inserton/Extracton Tool 91285-1 and Replacement Tp Kts 543382-[ ] Instructon Sheet 408-9404 19 JUN 12 PROPER USE GUIDELINES Cumulatve Trauma Dsorders can result from the prolonged use of manually powered

More information

Shur-Plug*.156 Diameter Terminals and Receptacle Contacts

Shur-Plug*.156 Diameter Terminals and Receptacle Contacts Shur-Plug*.156 Dameter Termnals and Receptacle Contacts Applcaton Specfcaton 114-2042 07 NOV 12 All numercal values are n metrc unts [wth U.S. customary unts n brackets]. Dmensons are n mllmeters [and

More information

A Comparison of Two Equivalent Real Formulations for Complex-Valued Linear Systems Part 2: Results

A Comparison of Two Equivalent Real Formulations for Complex-Valued Linear Systems Part 2: Results AMERICAN JOURNAL OF UNDERGRADUATE RESEARCH VOL. 1 NO. () A Comparson of Two Equvalent Real Formulatons for Complex-Valued Lnear Systems Part : Results Abnta Munankarmy and Mchael A. Heroux Department of

More information

Dual Functional Z-Source Based Dynamic Voltage Restorer to Voltage Quality Improvement and Fault Current Limiting

Dual Functional Z-Source Based Dynamic Voltage Restorer to Voltage Quality Improvement and Fault Current Limiting Australan Journal of Basc and Appled Scences, 5(5): 287-295, 20 ISSN 99-878 Dual Functonal Z-Source Based Dynamc Voltage Restorer to Voltage Qualty Improvement and Fault Current Lmtng M. Najaf, M. Hoseynpoor,

More information

current activity shows on the top right corner in green. The steps appear in yellow

current activity shows on the top right corner in green. The steps appear in yellow Browzwear Tutorals Tutoral ntroducton Ths tutoral leads you through the basc garment creaton process usng an llustrated step by step approach. Each slde shows the actual applcaton at the stage of the acton

More information

C O N C E A L E D F I X I N G. PH:

C O N C E A L E D F I X I N G.   PH: C O N C E A L E D I X I N G D I Y S l a t Systems PH: 1300 336 237 Alumnum Concealed xng Slat Systems Our Concealed xng Alumnum Slat range offers the latest n archtectural style combned wth a unque nstall

More information

High Speed ADC Sampling Transients

High Speed ADC Sampling Transients Hgh Speed ADC Samplng Transents Doug Stuetzle Hgh speed analog to dgtal converters (ADCs) are, at the analog sgnal nterface, track and hold devces. As such, they nclude samplng capactors and samplng swtches.

More information

VRT014 User s guide V0.8. Address: Saltoniškių g. 10c, Vilnius LT-08105, Phone: (370-5) , Fax: (370-5) ,

VRT014 User s guide V0.8. Address: Saltoniškių g. 10c, Vilnius LT-08105, Phone: (370-5) , Fax: (370-5) , VRT014 User s gude V0.8 Thank you for purchasng our product. We hope ths user-frendly devce wll be helpful n realsng your deas and brngng comfort to your lfe. Please take few mnutes to read ths manual

More information

Precision interior and exterior chamfer measuring instruments

Precision interior and exterior chamfer measuring instruments , mm Made Precson n Hgh Prec TN COATED 2 HV % on 9 Exteror chamfer measurng 7 3 98 7 3 2 6 5 4, mm 2 3 5 8 7 9 7 3 9 Chamfer sze Chamferangles 45 Length L 9 Workpece Precse measurement of chamfer wth 45

More information

Operator's Manual A1000. Applicator. Made in Germany

Operator's Manual A1000. Applicator. Made in Germany Operator's Manual Applcator A1000 Made n Germany 2 Operator's Manual - Translaton of the Orgnal Verson 2 for the followng products Famly A1000 Edton: 03/2016 - Part No. 9009599 Copyrght Ths documentaton

More information

PRACTICAL, COMPUTATION EFFICIENT HIGH-ORDER NEURAL NETWORK FOR ROTATION AND SHIFT INVARIANT PATTERN RECOGNITION. Evgeny Artyomov and Orly Yadid-Pecht

PRACTICAL, COMPUTATION EFFICIENT HIGH-ORDER NEURAL NETWORK FOR ROTATION AND SHIFT INVARIANT PATTERN RECOGNITION. Evgeny Artyomov and Orly Yadid-Pecht 68 Internatonal Journal "Informaton Theores & Applcatons" Vol.11 PRACTICAL, COMPUTATION EFFICIENT HIGH-ORDER NEURAL NETWORK FOR ROTATION AND SHIFT INVARIANT PATTERN RECOGNITION Evgeny Artyomov and Orly

More information

MCP 2.8 mm Contact System and Wire Seal for 1P Starter Motor Connectors

MCP 2.8 mm Contact System and Wire Seal for 1P Starter Motor Connectors MCP 2.8 mm Contact System and Wre Seal for 1P Starter Motor Connectors Applcaton Specfcaton 114-13295 05 MAY 11 All numercal values are n metrc unts [wth U.S. customary unts n brackets]. Dmensons are n

More information

Metal-Clad Switchgear VacClad-W Medium Voltage Drawout Vacuum Breakers 5 kv (26-Inch Wide) Inch (660.4 mm) Wide 5 kv 250 MVA Switchgear

Metal-Clad Switchgear VacClad-W Medium Voltage Drawout Vacuum Breakers 5 kv (26-Inch Wide) Inch (660.4 mm) Wide 5 kv 250 MVA Switchgear .- Metal-Clad Swtchgear VacClad-W Medum Voltage (-Inch Wde) General Descrpton October 0 Sheet 00 -Inch (0. mm) Wde MVA Swtchgear Fully Wthdrawn Breaker Automatc Shutters Fused PT Drawer Applcaton Ths narrow

More information

LITECOM. Self-contained emergency luminaires

LITECOM. Self-contained emergency luminaires LITECOM Self-contaned emergency lumnares Legal nformaton Copyrght Copyrght Zumtobel Lghtng GmbH All rghts reserved. Manufacturer Zumtobel Lghtng GmbH Schwezerstrasse 30 6850 Dornbrn AUSTRIA Tel. +43-(0)5572-390-0

More information

100 Watt DC-DC Converters Q Series

100 Watt DC-DC Converters Q Series Bengn Envronment DC-DC Converters 100 Watt Q Seres 100 Watt DC-DC Converters Q Seres Input to output solaton Sngle output: Seres 24Q...48Q1000 Double output: Seres 24Q...48Q2000 Very hgh effcency of up

More information

3. Pat t er n, Mold and Cor e Des ign

3. Pat t er n, Mold and Cor e Des ign 3. Pat t er n, Mold and Cor e Des gn The most mportant decson n pattern and mold desgn s about the partng lne. It affects and s affected by part orentaton, desgn of pattern and cores, number of cavtes

More information

A Feasible Approach to the Evaluation of the Tractions of Vehicle Wheels Driven by DC Motors

A Feasible Approach to the Evaluation of the Tractions of Vehicle Wheels Driven by DC Motors A Feasble Approach to the Evaluaton of the Tractons of Vehcle Wheels Drven by DC Motors Jeh-Shan Young Insttute of Vehcle Engneerng, Natonal Changhua Unversty of Educaton Changhua, Tawan, R.O.C. and Sheng-You

More information

THEORY OF YARN STRUCTURE by Prof. Bohuslav Neckář, Textile Department, IIT Delhi, New Delhi. Compression of fibrous assemblies

THEORY OF YARN STRUCTURE by Prof. Bohuslav Neckář, Textile Department, IIT Delhi, New Delhi. Compression of fibrous assemblies THEORY OF YARN STRUCTURE by Prof. Bohuslav Neckář, Textle Department, IIT Delh, New Delh. Compresson of fbrous assembles Q1) What was the dea of fbre-to-fbre contact accordng to van Wyk? A1) Accordng to

More information

THE GENERATION OF 400 MW RF PULSES AT X-BAND USING RESONANT DELAY LINES *

THE GENERATION OF 400 MW RF PULSES AT X-BAND USING RESONANT DELAY LINES * SLAC PUB 874 3/1999 THE GENERATION OF 4 MW RF PULSES AT X-BAND USING RESONANT DELAY LINES * Sam G. Tantaw, Arnold E. Vleks, and Rod J. Loewen Stanford Lnear Accelerator Center, Stanford Unversty P.O. Box

More information

RC Filters TEP Related Topics Principle Equipment

RC Filters TEP Related Topics Principle Equipment RC Flters TEP Related Topcs Hgh-pass, low-pass, Wen-Robnson brdge, parallel-t flters, dfferentatng network, ntegratng network, step response, square wave, transfer functon. Prncple Resstor-Capactor (RC)

More information

Calculation of the received voltage due to the radiation from multiple co-frequency sources

Calculation of the received voltage due to the radiation from multiple co-frequency sources Rec. ITU-R SM.1271-0 1 RECOMMENDATION ITU-R SM.1271-0 * EFFICIENT SPECTRUM UTILIZATION USING PROBABILISTIC METHODS Rec. ITU-R SM.1271 (1997) The ITU Radocommuncaton Assembly, consderng a) that communcatons

More information

Fiber length of pulp and paper by automated optical analyzer using polarized light (Five-year review of T 271 om-12) (no changes since Draft 1)

Fiber length of pulp and paper by automated optical analyzer using polarized light (Five-year review of T 271 om-12) (no changes since Draft 1) OTICE: Ths s a DRAFT of a TAPPI Standard n ballot. Although avalable for publc vewng, t s stll under TAPPI s copyrght and may not be reproduced or dstrbuted wthout permsson of TAPPI. Ths draft s OT a currently

More information

PORTABLE JAMMER COUNTER-MEASURE SOLUTIONS

PORTABLE JAMMER COUNTER-MEASURE SOLUTIONS AARONIA AARTOS PORTABLE JAMMER COUNTER-MEASURE SOLUTIONS Backpack jammng system wth 120 W output power and up to 2,5 km range Hghlghts: Up to 120 W output power Hgh range of up to 2,5 km Covers 5 frequency

More information

HUAWEI TECHNOLOGIES CO., LTD. Huawei Proprietary Page 1

HUAWEI TECHNOLOGIES CO., LTD. Huawei Proprietary Page 1 Project Ttle Date Submtted IEEE 802.16 Broadband Wreless Access Workng Group Double-Stage DL MU-MIMO Scheme 2008-05-05 Source(s) Yang Tang, Young Hoon Kwon, Yajun Kou, Shahab Sanaye,

More information

antenna antenna (4.139)

antenna antenna (4.139) .6.6 The Lmts of Usable Input Levels for LNAs The sgnal voltage level delvered to the nput of an LNA from the antenna may vary n a very wde nterval, from very weak sgnals comparable to the nose level,

More information

Voltage Quality Enhancement and Fault Current Limiting with Z-Source based Series Active Filter

Voltage Quality Enhancement and Fault Current Limiting with Z-Source based Series Active Filter Research Journal of Appled Scences, Engneerng and echnology 3(): 246-252, 20 ISSN: 2040-7467 Maxwell Scentfc Organzaton, 20 Submtted: July 26, 20 Accepted: September 09, 20 Publshed: November 25, 20 oltage

More information

Operating Instructions. MarSurf M RD 18

Operating Instructions. MarSurf M RD 18 Operatng Instructons MarSurf M 300 + RD 18 DE Deutsch EN Englsh FR Franças IT Italano ES Español PT Português Mahr GmbH, MarSurf M 300 + RD 18 Mahr GmbH, MarSurf M 300 + RD 18 Dear valued customer, Congratulatons

More information

Instructions for Use. PetChatz.com. PetChatz.com

Instructions for Use. PetChatz.com. PetChatz.com Instructons for Use PetChatz.com PetChatz.com POWER ON/OFF LED PET-SAFE MICROPHONE SOUND DETECTOR MANUAL TREAT RELEASE LOW TREAT LED LOW-LIGHT HD CAMERA for hgh-qualty vdeo MOTION DETECTION FULL-COLOR

More information

ANNUAL OF NAVIGATION 11/2006

ANNUAL OF NAVIGATION 11/2006 ANNUAL OF NAVIGATION 11/2006 TOMASZ PRACZYK Naval Unversty of Gdyna A FEEDFORWARD LINEAR NEURAL NETWORK WITH HEBBA SELFORGANIZATION IN RADAR IMAGE COMPRESSION ABSTRACT The artcle presents the applcaton

More information

Table of contents Document code: DPD00288B2 Edited:

Table of contents Document code: DPD00288B2 Edited: Table of contents Document code: DPD00288B2 Edted: 18.06.2010 1. Safety 3 1.1 Warnngs 3 1.2 Safety nstructons 5 1.3 Earthng and earth fault protecton 5 1.4 Before runnng the motor 6 2. Recept of delvery

More information

LED Fixture Controller ELED1 Programming Guide

LED Fixture Controller ELED1 Programming Guide LED Fxture Controller ELED1 Programmng Gude ELED1-AUN ELED1-AUS Copyrght 2018 Echoflex Solutons, Inc. All rghts reserved. Product nformaton and specfcaton detals subject to change Echoflex Solutons 38924

More information

Instruction Sheet ROTA- CRIMP* Hand Crimping Tools and

Instruction Sheet ROTA- CRIMP* Hand Crimping Tools and Instructon Sheet ROTA- CRIMP* Hand Crmpng Tools 08-09 6007 and 6007- APR PROPER USE GUIDELINES Cumulatve Trauma Dsorders can result from the prolonged use of manually powered hand tools. Hand tools are

More information

Ultra Sonic Flow Rate Measurements in Large Pipes and open Channels

Ultra Sonic Flow Rate Measurements in Large Pipes and open Channels Ultra Sonc Flow Rate Measurements n Large Ppes and open Channels Dr. Mchael Teufel I Summary Correlaton s a mathematcal tool whch, enabled by developments of fast and powerful mcroprocessors n last few

More information

INSTRUCTION MANUAL BENCH LATHE

INSTRUCTION MANUAL BENCH LATHE WLLOUGHBY COMMUNTY MEN'S SHED mens 296C Salors Bay Road, l _ L^ NORTHBRDGE N.S.W 2063 The Wlkmghby Communty" NSTRUCTON MANUAL BENCH LATHE Before usng be sure to read ths manual carefully -C6- Safety nstructons

More information

Figure 1. DC-DC Boost Converter

Figure 1. DC-DC Boost Converter EE36L, Power Electroncs, DC-DC Boost Converter Verson Feb. 8, 9 Overvew Boost converters make t possble to effcently convert a DC voltage from a lower level to a hgher level. Theory of Operaton Relaton

More information

Utility Knives & Blades

Utility Knives & Blades www.rwn.com.au Utlty Knves & s IRWIN Revolutonses Tradtonal Utlty s In 2003, IRWIN revolutonsed tradtonal utlty blades wth the release of B-Metal technology. As the name mples, B-Metal blades are produced

More information

Machine Coordinate System. Coordinate Transformation. Work Coordinate System

Machine Coordinate System. Coordinate Transformation. Work Coordinate System Outlne MC Programmng g II Coordnate Systems MCS vs. WCS Coordnate Transformaton Return to Home Poston Tool Change Commands Cutter Length Offset Compensaton General Structure of NC program Intalzaton Tool

More information

TITLE ASSEMBLY DRAWING MTA - 5" APPROVALS DRAWN DATE

TITLE ASSEMBLY DRAWING MTA - 5 APPROVALS DRAWN DATE REV. DESCRPTON APPROVED A SEE DCN: 7762 0/29/200 ha k9, EXPRESS PROR WRTTEN CONSENT OF CELESCO TRANSDUCER PRODUCTS N( 20630 Plummer st Chatsworth, CA. 93 G MTA 5" E.GARCA 029200 SZE CODE DENT. NO DWG.

More information

ph fax

ph fax www.customron.com ph 800.732.7699 fax 507.732.7837 Balusters, pckets, spndles these are the bones of a star ralng system. At Custom Iron, we commonly refer to these as balusters. And, uncommonly, we nvent

More information

Evaluate the Effective of Annular Aperture on the OTF for Fractal Optical Modulator

Evaluate the Effective of Annular Aperture on the OTF for Fractal Optical Modulator Global Advanced Research Journal of Management and Busness Studes (ISSN: 2315-5086) Vol. 4(3) pp. 082-086, March, 2015 Avalable onlne http://garj.org/garjmbs/ndex.htm Copyrght 2015 Global Advanced Research

More information

Figure 1. DC-DC Boost Converter

Figure 1. DC-DC Boost Converter EE46, Power Electroncs, DC-DC Boost Converter Verson Oct. 3, 11 Overvew Boost converters make t possble to effcently convert a DC voltage from a lower level to a hgher level. Theory of Operaton Relaton

More information

Digital Transmission

Digital Transmission Dgtal Transmsson Most modern communcaton systems are dgtal, meanng that the transmtted normaton sgnal carres bts and symbols rather than an analog sgnal. The eect o C/N rato ncrease or decrease on dgtal

More information

1 Signs and symbols. 4 Installation 5 Active window 6 Commissioning Filter settings edali addressing. 6.4 Addressing. 7 General functions

1 Signs and symbols. 4 Installation 5 Active window 6 Commissioning Filter settings edali addressing. 6.4 Addressing. 7 General functions Table of contents 1 Sgns and symbols... 5 2 Changes ntroduced... wth masterconfigurator 2.10 6 3 Introducton... 7 4 Installaton... 8 5 Actve wndow... 10 6 Commssonng... 12 6.1 Selectng... an nterface 12

More information

N- and P-Channel 2.5-V (G-S) MOSFET

N- and P-Channel 2.5-V (G-S) MOSFET S456DY N- and P-Channel.5-V (G-S) MOSFET PRODUCT SUMMARY V DS (V) R DS(on) (Ω) (A).5 at 7. N-Channel.35 at V GS =.5 V 6. FEATURES Halogen-free Accordng to IEC 649-- Defnton TrenchFET Power MOSFET:.5 Rated

More information

An Adaptive Over-current Protection Scheme for MV Distribution Networks Including DG

An Adaptive Over-current Protection Scheme for MV Distribution Networks Including DG An Adaptve Over-current Protecton Scheme for MV Dstrbuton Networks Includng DG S.A.M. Javadan Islamc Azad Unversty s.a.m.javadan@gmal.com M.-R. Haghfam Tarbat Modares Unversty haghfam@modares.ac.r P. Barazandeh

More information

SERVICE MANUAL

SERVICE MANUAL SERVCE MANUAL SEWNG MACHNE MODELS 11602090 12714090 TABLE OF CONTENTS. LOCATE AND DENTFY THE PARTS... 2. WND THE BOBBN... 3. PREPARE YOUR TOP THREAD..., STTCH SELECTOR/STTCH LENGTH CONTROLS... 4- & 4-2

More information

EMA. Education Maintenance Allowance (EMA) Financial Details Form 2017/18. student finance wales cyllid myfyrwyr cymru.

EMA. Education Maintenance Allowance (EMA) Financial Details Form 2017/18. student finance wales cyllid myfyrwyr cymru. student fnance wales cylld myfyrwyr cymru Educaton Mantenance Allowance (EMA) Fnancal Detals Form 2017/18 sound advce on STUDENT FINANCE EMA Educaton Mantenance Allowance (EMA) 2017/18 /A How to complete

More information

Research of Dispatching Method in Elevator Group Control System Based on Fuzzy Neural Network. Yufeng Dai a, Yun Du b

Research of Dispatching Method in Elevator Group Control System Based on Fuzzy Neural Network. Yufeng Dai a, Yun Du b 2nd Internatonal Conference on Computer Engneerng, Informaton Scence & Applcaton Technology (ICCIA 207) Research of Dspatchng Method n Elevator Group Control System Based on Fuzzy Neural Network Yufeng

More information

TheraPro HR Brief description. 1. Scope of delivery

TheraPro HR Brief description. 1. Scope of delivery . Bref descrpton 44 The HR9 radator controller s certfed by eu.bac.. Scope of delvery The radator controller packagng contans: Radator controller wth valve baseplate M x.5; batteres ncluded Dsplay support

More information

2E - 3E High Wind Kit Manual

2E - 3E High Wind Kit Manual Yag Dpole Vertcal (Patent# 6,677,914 E - 3E Hgh Wnd Kt Manual Antarctca at 7 mph SteppIR Antennas 11-116th Ave NE, Sute -, Bellevue, WA 984 Tel: 4-43-191 Fax: 4-46-441 Tech Support: 4-891-6134 www.steppr.com

More information

Connector Assemblies 06 JUN 11 Rev C

Connector Assemblies 06 JUN 11 Rev C Applcaton Specfcaton Power Seres 50 114-13071 Connector Assembles 06 JUN 11 All numercal values are n metrc unts [wth U.S. customary unts n brackets]. Dmensons are n mllmeters [and nches]. Unless otherwse

More information

DALI gateway Plus Order No

DALI gateway Plus Order No KNX Product documentaton Issue: 18.09.2015 21803200 DALI gateway Plus Table of Contents KNX Product documentaton 1 Product defnton... 4 1.1 Product catalogue... 4 1.2 Functon... 4 2 Installaton, electrcal

More information

Comparison of Two Measurement Devices I. Fundamental Ideas.

Comparison of Two Measurement Devices I. Fundamental Ideas. Comparson of Two Measurement Devces I. Fundamental Ideas. ASQ-RS Qualty Conference March 16, 005 Joseph G. Voelkel, COE, RIT Bruce Sskowsk Rechert, Inc. Topcs The Problem, Eample, Mathematcal Model One

More information

Service Manual 5414/5416. Vacuum-Belt Applicator. Made in Germany

Service Manual 5414/5416. Vacuum-Belt Applicator. Made in Germany Servce Manual Vacuum-Belt Applcator 5414/5416 Made n Germany 2 Servce Manual 2 for the followng products Famly Vacuum-Belt Applcator Type 5414L 5414R 5416L 5416R Edton: 04/2018 - Part No. 9003095 Copyrght

More information