PTN-1B/PTH-1B HG 3 HG 2 PTN-1B/PTH-1B. Type. Standard. Power supply. Semi-standard. Bore 24 V DC 2V 0.05A. f50 f63 f80 f100 f125 to f160 f180 to f250
|
|
- Mavis Mabel Brooks
- 5 years ago
- Views:
Transcription
1 2 f f f f f f f f f f f f Power supply V DC2V.A Standard Semi-standard Type Nominal pressure Maximum allowable pressure Proof test pressure Minimum operating pressure Working speed range Working temperature range (ambient temperature) Structure of cushioning Adaptable fluid Tolerance for thread Tolerance of strokes Mounting style Rod series Accessories MPa 9 MPa General purpose type 21 MPa Cap side:. MPa or less Rod side:. MPa or less : to mm/s to : to mm/s to 2: to 2mm/s Metal fitting system Petroleum-based fluid (When using another fluid, refer to the table of fluid adaptability.) JIS 6g/6H to mm. 1 to 2mm1. 1 to 6mm1. 6 to mm to 1mm 1.6 to 2mm 1. SDFAFYLALBTATC Rod B MPa MPa Standard type: to Switch Set (AX/AZ type): to Switch Set (WR/WS type): to (No freezing) SDFYLATATC Rod eye (T-end), rod clevis (Y-end) with pin, floating joint (F-end) (for MPa), lock nut Boots : Nylon tarpaulin : Chloroprene : Conex Accuracy Linearity Resolution Repeatability Temperature characteristics Response speed Working temperature range Impact resistance Vibration resistance Protective structure Connection Supplied connector Applicable cable (not supplied).%fs or mmtyp.1%fs or mm or less.1%fs or mm or less ppmfs/ or mm/ or less Current output: 4 to 2 ma Load resistance: Ω or less For the voltage output ( to V, etc.), contact us. Scanning frequency 1 khz 2 to (No freezing) G 2m/s 6 G or Hz2mmPP IP6 kpa, min Pin No Signal V DC V COM Shield to be connected to V by user V and COM are connected internally. OMRON XS2C-D4S1 Outer diameter: f to f6 mm Wire size:. to. mm² f f to f1 to f2 to to to Type Cushion ring length L f to f to f1 to f2 L R L R 1 to 1 to 1 1 to 2 to 2 to 2 2 Cushion ring parallel part length R
2 4 fffffff fffff ffffff Reed sensor Solid state sensor Cutting oil proof type Solid state sensor WR WRF 6 WR BE AX21CE-1 BF AXCE-1 CE AX2CE-1 CF AX2CE-1 RA AXWCE RB AZWCE RE AX2WCE RF AZ2WCE CT AX2CE-1 CU AX2CE-1 CV AX21BCE-1 CW AZ2CE-1 CX AZ2CE-1 CY AZ21BCE-1 to ma to ma to 2mA to 2mA None Provided Provided Provided. mm², 2-core, outer dia. f4 mm, rear wiring. mm², 2-core, outer dia. f4 mm, rear wiring. mm², 2-core, outer dia. f4 mm, rear wiring. mm², 2-core, outer dia. f4 mm, rear wiring. mm², 2-core, outer dia. f4 mm, upper wiring 4-pin connector type, upper wiring Type Sensor symbol Max. Load voltage range Load current range switching capacity Protective circuit Indicating lamp Wiring method Cord length Applicable load AF AX1CE 1. None AG AXCE DC to V DC to ma LED DC1.W (Lights in red. mm², 2-core, AH AX1CE AC to V AC to 2mA outer dia. f4 mm, 1. AC2VA Provided when sensing) AJ AXCE rear wiring AE AXCE DC: V or less AC: V or less DC: ma or less AD: 2 ma or less None None AK AXACE AC to V to 2mA 2VA LED 4-pin connector. Provided (Lights in red AL AXBCE DC to V to ma 1.W type, rear wiring when sensing). LED. mm², 2-core, outer dia. AM AXCE f4 mm, rear wiring AC/DC9 to 2V to ma B contact Provided (Lights in red. mm², 2-core, outer dia. AY AZCE output when not sensing) f4 mm, upper wiring Neon lamp. mm², 2-core, S SR AC to 22V 2 to ma VA Provided (Lights when outer dia. f6 mm, not sensing) rear wiring 2 4 WS2-1 WS2-1F WS2-1 DC to V AC to V DC to V DC to V DC to V DC to V DC to ma AC to 2mA to ma DC1.W AC2VA LED (Lights in red when sensing) LED (Lights in red when sensing) LED (2-LED type in red/green) LED. mm², 2-core, outer dia. f4 mm, rear wiring (Lights in red. mm², 2-core, outer dia. when sensing) f4 mm, upper wiring. mm², 2-core, outer dia. LED (2-LED f4 mm, rear wiring type in red/green). mm², 2-core, outer dia. f4 mm, upper wiring LED (2-LED type in red/green) 4-pin connector type, rear wiring Small relay, programmable controller Small relay, programmable controller
3 6 Type Model number Applicable input signals Display range Resolution Response frequency Linearity Signals Monitor output Sampling speed Display speed Display method Control input Control output Power supply voltage Ambient temperature Ambient humidity Analog PQCPA-CU-A Analog voltage/analog current Stroke1/ 1 khz.2%fs Voltage input to V Voltage input 1 to V Current input 4 to 2 ma Voltage output Note) times/sec times/sec Display by fluorescent display tube No-voltage input (reed sensor/solid state sensor) Open collector Max. rating: V DC, ma (Provided with multi-point output function ( points) to enable to individually set the upper and lower limits and pulse position correcting function) V DC % to (No freezing) to %RH (No condensing) Type Analog input Pulse input Model number Functions PQCPA-CU-A-A PQCPA-CU-A-V Display of position Bank switching Multi-point output Positional data hold PQCPA-CU-P- PQCPA-CU-P- PQCPA-CU-P- Display of position Bank switching Multi-point output Positional data hold setting signal Correcting function Series Absolute type Pulse PQCPA-CU-P Phase AB 2 khz Open collector input Differential input (line driver input) V voltage input V voltage input Linear pulse encoder Line driver output PTN-1B PTH-1B PTT-1B PSR-1A P- P- 1P- Detection method Signal type Analog type (4 to 2 ma, to V) Analog type (1 to V) Encoder type f
4 CN1 CN2 CN4 CN CN1 CN2 CN4 CN CN1 CN2 CN4 CN 9 Pin No Pin No Pin No. 1 2 Description Voltage/current input NC Voltage/current GND Phase A Phase A Phase B Phase B V V GND Description Pout Vss A pulse A pulse GND B pulse B pulse GND Description P N PE Signals Analog input Analog input Pulse input Pulse input Pulse input Pulse input Power supply output Power supply output Power supply output/phase AB GND Signals Analog output Analog output Pulse output Pulse output Pulse output Pulse output Signals Power supply Power supply Power supply Pin No Description setting signal Positional data hold Correcting function Bank switching Bank switching 1 Bank switching 2 Reserved input Reserved input common common Multi-point output signal Multi-point output signal 1 Multi-point output signal 2 Multi-point output signal Multi-point output signal 4 Reserved output Reserved output Reserved output common common For details, see the instruction manual. Signals PQCPA-CU-A-A PQCPA-CU-A-V PTH-1B PTN-1B PTT-1B P- P- 1P- PSR-1A PQCPA-CV1- PQCPA-CV2- PQCPA-CV- CN1 connector CN1 connector PQCPA-CU-P- PQCPA-CU-P- PQCPA-CU-A-V PQCPA-IO CN1 connector
5 mm Basic weight (SD style) Additional weight per mm of stroke LA Mounting accessory weight LB FA FY TA TC Rod end attachment weight Rod eye (T-end) Rod clevis (Y-end) with pin Floating joint (F-end) Lock nut f f f f f (mm) f f AX type Cord length 1. m Cord length m Connector type SR type Cord length m WR/WS type.9..
6 SD DF OF f99. f1. f1. f9. f f2 f Rod dia. Material Heat proof Standard Semi-standard 2 Nylon tarpaulin Chloroprene Conex f ff ff ff f ff ff ff ff ff f ff ff f f f f1 f1 f2 A Rod B B f f f f f f1 f f1 f1 M2. M1. M91. M41. M6 M22 M62 M2 M2 M2 M2 M2 MM f2 f. f f f1 f f9 f f2 S VD 2 2 f f f1 f1 f2 E EE /2 /2 1 /4 1 /2 1 /2 Rc2 BB EV DD M1. M1. M1. M1. M221. M2. M21. M21. M1. M1. M91. M1. F FP G H HL PJ J PL 2 TG W Y ZS ZT f 1 f f1 1 1 f f2 2 WW X f1,, f J
7 LA DF OF f99. f1. f1. f9. f f2 f Rod dia. ff f ff ff f ff Material Heat proof Standard Semi-standard 2 Nylon tarpaulin Chloroprene Conex ff ff f ff ff ff ff f f f f1 f1 f2 A Rod B B f f f f f f1 f f1 f1 M2. M1. M91. M41. M6 M22 M62 M2 M2 M2 M2 M2 MM f2 f. f f f1 f f9 f f2 S VD 2 2 f f f1 f1 f /2 /2 1/4 1/2 1/2 Rc2 E EE EH EV FP LH PJ SB SS ST SU SW SY TS US W XB XS Y ZT f f f f22 f26 f26 f f f f6 f f f 1 f f1 1 1 f f2 2 WW X f1,, f
8 1 LB DF OF f99. f1. f1. f9. f f2 f Rod dia. ff ff f ff ff ff ff ff ff ff ff ff Material Heat proof Standard Semi-standard 2 Nylon tarpaulin Chloroprene Conex f f f1 f1 f2 A Rod B B f f f f f1 f f1 f1 M1. M91. M41. M6 M22 M62 M2 M2 M2 M2 M2 MM f. f f f1 f f9 f f2 S VD 2 2 f f1 f1 f2 AB f f f22 f26 f26 f f f f6 f f AT 2 AO 2 29 AU 66 HL PJ W XA Y AE AH E EE /2 1 /4 1 /2 1 /2 Rc2 EV FP ZA ZT SA TR UA f f1 1 1 f f2 2 WW X f1,,
9 19 FA DF OF f99. f1. f1. f9. f f2 f ff f Rod dia. ff ff f ff ff ff f ff ff ff ff Material Heat proof Standard Semi-standard 2 Nylon tarpaulin Chloroprene Conex f f f f1 f1 f2 A Rod B B f f f f f f1 f f1 f1 M2. M1. M91. M41. M6 M22 M62 M2 M2 M2 M2 M2 MM f2 f. f f f1 f f9 f f2 S VD 2 2 f f f1 f1 f2 E EE /2 /2 1 /4 1 /2 1 /2 Rc2 EV F FB f f f f22 f26 f26 f f f f6 f f FE HL LL PJ R UF W YP ZT TF f 1 f f1 1 1 f f2 2 WW X f1,, f
10 2 21 FY f99. f1. f1. f9. f f2 f Rod dia. f ff ff ff f ff ff ff f ff ff ff ff Material Heat proof Standard Semi-standard 2 Nylon tarpaulin Chloroprene Conex f f f f1 f1 f2 A Rod B B f f f f f f1 f f1 f1 M2. M1. M91. M41. M6 M22 M62 M2 M2 M2 M2 M2 MM f2 f. f f f1 f f9 f f2 S VD 2 2 f 1 f f1 1 1 f f2 2 WW X f f f1 f1 f2 E EE /2 /2 1 /4 1 /2 1 /2 Rc2 EV FB f f f f22 f26 f26 f f f f6 f f FE LY LL PJ R TF UF W YP ZY FY f1,, f
11 22 TA ff ff ff f ff ff f ff ff ff Material Heat proof Standard Semi-standard 2 Nylon tarpaulin Chloroprene Conex f f f f1 A 1 Rod B B f f f f f f1 f M2. M1. M91. M41. M6 M22 M62 M2 MM f2 f. f f f1 f f9 S VD 2 2 f f f1 E EE /2 /2 EV FP PJ TD fe9 f.e9 f.e9 fe9 fe9 e9 e9 f1e9 TL.. 1 UT JR R2. R2. R2. R R R4 R4 R4 TC W XG ZT f 1 f f1 1 1 WW X f1,, f
12 TC f99. f1. f1. f9. f f2 f Rod dia. ff f ff ff f ff ff ff f ff ff ff ff Material Heat proof Standard Semi-standard 2 Nylon tarpaulin Chloroprene Conex f f f f1 f1 f2 A Rod B B f f f f f f1 f f1 f1 M2. M1. M91. M41. M6 M22 M62 M2 M2 M2 M2 M2 MM f2 f. f f f1 f f9 f f2 S VD 2 2 f f f1 f1 f2 E EE /2 /2 1 /4 1 /2 1 /2 Rc2 EV BD FP JR R2. R2. R2. R R R4 R4 R4 R4 R R R Min. PH PJ TD fe9 f.e9 f.e9 fe9 fe9 e9 e9 f1e9 e9 f9e9 fe9 fe9 TL TM UM W XV ZT f 1 f f1 1 1 f f2 2 WW X f1,, f
13 26 2 AX type RV RY WR/WS type AX type WR/WS type Reed sensor AX type Solid state sensor UX WR type Min. dimension PH WS type AX type WR type WS type f f f Reed sensor Solid state sensor AX1 WR type AX2 WS type Operating range Hysteresis Operating range Hysteresis Operating range Hysteresis Operating range to Hysteresis 4 to 6 to to f to to 2 or less to 1 to 2 or less 4 to 1 or less to 1 to 1 or less to 2 6 to
14 2 29 ff ff f ff ff CK f2 f. f. f f f1 f9 f f f f f1 f1 f2 RYH--H RYH--H RYH-9-H RYH-4-H RYH-64-H RYH-2-H RYH-6-H RYH--H RYH--H RYH--H RYH--H RYH--H Part number AV BL CE CL CR 9 M2. M1. M91. M41. M6 M22 M62 M2 M2 M2 M2 M2 LE H f H f H f H f H f H f H f H f H f CM H f H f CV CW ED ER R2 R R R R4 R2 R2 R R9 R99 R2 R2 RA SD YD Part number f f f1 f1 f2 RTH--H RTH--H RTH-9-H RTH-4-H RTH-64-H RTH-2-H RTH-6-H RTH--H RTH--H RTH--H RTH--H RTH--H AV CE CR 9 CK f2h f.h f.h fh fh H H f1h H f9h fh fh LE 2 9 RA ED f49 f62 f62 f9 f f f EF ER R29 R9 R9 R R4 R4 R4 R R9 R99 R2 R2 EM. J 2 M2. M1. M91. M41. M6 M22 M62 M2 M2 M2 M2 M2 J H f f Part number RFH- RFH- A M2. M1. B2 e FA 62 FC 6 FD 21 FJ 9 1 FK FM f64 f6 FN 6 FQ FR 2 h 1 B1
15 f f f1 BL C CK f2 f. f. f f f1 D E f f f1 F G H I... J 2 22 K L f f f f f f f f M6 M6 M6 M M M M M Retainer mounting bolt size
16 f f f1 f1 f2 Part number LNH-F-H LNH-F-H LNH-9F-H LNH-4F-H LNH-64F-H LNH-2F-H LNH-6F-H LNH-F-H LNH-F-H LNH-F-H LNH-F-H LNH-F-H B H f f f f f1 f1 f2 Dimension A d M2. M1. M91. M41. M6 M22 M62 M2 M2 M2 M2 M2 C
17 4 f M1. Tightening torque (Nm) Tightening torque (Nm) Tie rod screw Tie rod screw PTN-1B PTH-1B (mm) (mm) f1 M21. PTN-1B PTH-1B 4 M1. M1. f M1. M221. M M21. 4 f1 M M1. 1 M f2 M1. 1
PSR-1A HG 61 HG 60 PSR-1A. Basic style (SD) Flange type (FA) Foot type (LA) Additional weight per mm of stroke. Bore.
Basic.. Basic style (SD) Flange type (FA) Foot type (LA) Additional per mm of stroke.. Basic.. Additional per mm of stroke.. Basic.. Additional per mm of stroke..4 Amplifier.. 4....44 ff f f 4..4...4......4.
More information70/140M-3 HE 3 HE 2 70/140M-3. Type 70M-3 140M-3. Applicable fluid Seal material. Phosphate ester fluid. Water in oil fluid. Oil in water fluid
2 7/M- 7/M- f f f f f f f f f f f f Type Nominal pressure Maximum allowable pressure roof pressure Minimum operating pressure orking speed range orking temperature range (ambient temp. and oil temp.) tructure
More informationSTANDARD ELECTRIC LINEAR SERVOACTUATION PACKAGES
STANDARD ELECTRIC LINEAR SERVOACTUATION PACKAGES SIZE 3, AND HIGH PERFORMANCE DESIGN INCREASES MACHINE PRODUCTIVITY; INTEGRATED SYSTEM INCREASES EASE OF INSTALLATION Rev. A 79 WHAT MOVES YOUR WORLD TABLE
More informationIP50/51 IP50DCD IP50BRA/BRC IP50DBE/DBC IP50DCS/DCE. IntellpaK Compact Signal Converters CONVERTERS CONVERTERS. Mean value computing unit
IP50/51 IntellpaK Compact Signal Converters The IP50 and IP51 are compact, lightweight, high-accuracy signal converters, available in both AC and DC models. Features include a high-efficiency hybrid IC
More informationFEATURES. 15 m ft. 4 m ft. 2 m ft. 100 mm in. 600 mm in. 15 m ft. 4 m ft. 2 m ft. 100 mm 3.
273 Cylindrical Photoelectric Sensor SERIES Related Information General terms and conditions... F-3 Glossary of terms... P.1549~ guide... P.231~ General precautions... P.1552~ PHOTO PHOTO MEASURE -LS200
More informationTL-W. Standard Flat Inductive Proximity Sensors. Ordering Information. Front and side facing surface IP67 DC 2-wire and DC 3-wire models
Standard Flat Inductive Proximity Sensors Front and side facing surface IP67 DC -wire and DC -wire models Ordering Information DC -wire Models Shape distance Model Output and operating status mm MD1 *1
More informationPower connections, minimum and maximum wiring capabilities, tightening torque
Wiring - power terminals Power Observe the cable cross-sectional areas recommended in the standards. The soft starter must be grounded to conform to the regulations concerning leakage currents. If the
More informationPOINTAX 6000L2 Point Recorder
GOSSEN METRAWATT CAMILLE BAUER Special Features 6 measuring channels Last printed point visible from front Electrically isolated, earth-free measuring channels Process signals ranging from 0/4... 20 ma,
More informationMOBY-D Family Matrix
MOBY-D Family Matrix MOBY-D 13.56 MHz Passive Tags D100 6GT2600-0AD10 112 Bytes Min order of 50 D124 6GT2600-0AC00 112 Bytes D139 6GT2600-0AA00 44 Bytes D160 6GT2600-0AB00 44 Bytes D165 6GT2600-1AB00-0AX0
More informationHalton (Milton) LRO #20
Miscellaneous KH Bankruptcy April 7, 1921 Sept 18, 1922 1 1452 BL Bylaws Nov 13, 1855 Sept 23, 1960 1 778 DH Deposits Oct 31, 1894 Sept 30, 1966 1 5088 GR General Register Jan 9, 1866 Sept 1, 1955 1 8276
More informationSMAJ Series SMA/DO-214AC. Mechanical Data. Page <1> 29/01/10 V1.1. : Moulded plastic. : Pure tin plated lead free. : Indicated by cathode band.
SMA/DO-214AC Features: For surface mounted application. Low profile package. Built-in strain relief. Glass passivated junction. Excellent clamping capability. Fast response time : typically less than 1.0ps
More informationPNSG6 PSSG6. TS03 north bank PO3 PO1 PNSG5 PP1 PP2 PP3 PO2 PN1 PNSG7 PM2 PSSG5 CH 4: 73.1 PJ1 PK1 XY XY PSSG4 PI2 PSSG9 XY XY XY XY PA2 PI1 PH5 XY
TS04 pump hole 100 m south bank TS04 north bank PSSG6 TS03 pump hole end P END FLAG PSSG9 PP1 PP2 PP3 PO3 PO2 PN1 PNSG5 PN2 PQ1 PNSG4 PM1 PI3 PN3 PNSG7 PM2 PI4 PM3 PL1 PH3 PNSG3 PJ1 PH2 CH PK1 4: 79.4
More informationFunction Block DIGITAL PLL. Within +/- 5ppm / 10 years (Internal TCXO Stability) 1 External Reference Frequency Range: 10MHz +/- 100Hz
Features * Best Suited for Local Oscillator of Microwave Equipment with Low Phase Noise and Low Spurious Emission * Programmable Selection by Rotary Switch or Serial Control Signal * Built-in PLL Circuit
More informationAbsolute Rotary Encoder
Absolute Rotary Encoder Use the Tough (Rated IP64 for Degree of Protection) Combined with a PLC or Cam Positioner for Optimum Control and Ease-of-Use Incorporates a sealed bearing, meeting IP64 for durability
More informationTRD-J Series Incremental Encoders
Series Incremental Encoders Features mm thick shaft and ø5 mm body Vibration and shock resistant metal slit plate durable at 1, P/R Operating voltage ranging from 4.75 to 3 VDC Totem-pole output facilitating
More informationItem Symbol Condition Min. Typ. Max. Unit Power Supply for Logic Power Supply for LCD Drive. Input Voltage
6 FSTN LCD Module The display is a compact, full dot matrix, which is an STN gray positive LCD type, transflective rear polarizer with a yellow green backlight color. The AND3222MST- W can display TEXT
More informationSupply voltage Output configuration Resolution (P/R) Model 12 to 24 VDC Complementary output 100, 200, 360, 500, or 600 E6F-CWZ5G 1,000
Incremental 60-mm-dia. Rotary Encoder E6F-C The Strongest Shaft for Tough Jobs The strongest shaft of any OMRON Incremental Encoder (120 N in the radial direction and 50 N in the thrust direction). Water-
More informationInductive Proximity Sensor
Inductive Proximity Sensor Linear Proximity Sensor with High-accuracy Resolution Resolution is 0.05% of the maximum sensing distance. The model with a sensing distance of 1.2 mm ensures a resolution of
More informationMODEL: DLS. Telemetering System
POW RUN SA SA RT RU MODEL: DLS Telemetering System TELEMETERING UNIT Functions & Features Interfacing remote I/O devices with a modem for a telemetering system Process I/O (.0) [] POWER INPUT AC Power
More informationProposing control by a hydraulic servo and V/F inverters
Drive Goods SSCNET III/H Analog Speed Command Unit (Number of Control Axes: Axes) [DGAF/DGAF-P0] New Product Release No. Proposing control by a hydraulic servo and V/F inverters using a SSCNET III/H compatible
More informationMATHCOUNTS. 100 Classroom Lessons. August Prepared by
MATHCOUNTS 100 Classroom Lessons August 2000 Prepared by John Cocharo The Oakridge School 5900 W. Pioneer Parkway Arlington, TX 76013 (817) 451-4994 (school) jcocharo@esc11.net (school) cocharo@hotmail.com
More informationNPN PNP NPN PNP NPN PNP
Cam Positioner Low-Cost, High-Performance Electronic Cam Switch for Use with OMRON E6F Rotary Encoder Control outputs can be programmed to turn ON/OFF in 1 units of rotary encoder shaft rotation Handles
More informationIntegrated servo motor
R88E-AECT@, R88S-EAD@ Integrated servo motor Motor and drive integrated for space optimization Wide range of motors from 2.55 Nm to 25 Nm 3000 rpm rated speed Peak torque 300% of rated torque IP65 protection
More informationVisa Smart Debit/Credit Certificate Authority Public Keys
CHIP AND NEW TECHNOLOGIES Visa Smart Debit/Credit Certificate Authority Public Keys Overview The EMV standard calls for the use of Public Key technology for offline authentication, for aspects of online
More informationPERFORMANCE SPECIFICATION SHEET ELECTRON TUBE, MAGNETRON TYPE 6410A
INCH-POUND MIL-PRF-1/665G 22 July 2016 SUPERSEDING MIL-PRF-1/665F 12 June 2006 PERFORMANCE SPECIFICATION SHEET ELECTRON TUBE, MAGNETRON TYPE 6410A This specification is approved for use by all Departments
More informationSPECIFICATIONS FOR LCD MODULE
A M P I R E SPECIFICATIONS FOR LCD MODULE CUSTOMER CUSTOMER PART NO. AMPIRE PART NO. AG-24064B APPROVED BY DATE APPROVED BY CHECKED BY ORGANIZED BY Date :2007/2/7 AMPIRE CO., LTD. 1 RECORD OF REVISION
More information400W, 5V - 188V Surface Mount Transient Voltage Suppressor
400W, 5V - 188V Surface Mount Transient Voltage Suppressor FEATURES Low profile package Ideal for automated placement Glass passivated junction Built-in strain relief Excellent clamping capability Fast
More informationJR12 Jam Nut Mount Optical Encoder
Improving the Quality of Life through the Power in Light JR12 Jam Nut Mount Optical Encoder QPhase Design Features: Replaces Size 15 Pancake Resolver Bearing design simplifies encoder attachment Resolutions
More informationTorque Measuring Flange
Force Torque Measuring Flange Digital Telemetry Based, Short-Design, Robust, High Accuracy Type 025DF... Type 025DF... torque measuring flanges operate on the strain gage principle. The integral, digital
More information68HC11/Bidirectional-Compatible µp Reset Circuit MAX6314*
9-9; Rev ; /99 68HC/Bidirectional-Compatible General Description The low-power CMOS microprocessor (µp) supervisory circuit is designed to monitor power supplies in µp and digital systems. The s output
More informationMaterial: Weight: Bearing Life: Shaft Speed: Starting Torque: Mass Moment of Inertia: Shaft Loads:
Shaft Encoder - Ø 50 mm Shaft: Ø 6 mm to Ø 12 mm Resolution up to 12.500 ppr IP 65 (IP 67 option) Formerly named 2R or 2R-3L Automation / Electrical Specifications Code: Resolution: Supply Voltage: Voltage:
More informationDigital Lighting Systems, Inc. PD804-DMX. Eight Channel DMX Pack. (includes information for PD804-DMX-S) USER'S MANUAL. PD804-DMX-UM Rev.
, Inc. Eight Channel DMX Pack (includes information for -S) S S S S 4 8 USER'S MANUAL -UM User's Manual - Page GENERAL DESCRIPTION The is an 8-channel DMX- compatible dimmer pack. It contains three printed
More informationGeneral Specifications
General Specifications Signal Conditioner Cards OUTLINE Signal Conditioner Cards, which interface to the process, are installed in Signal Conditioner Nests. [Release 6] The signal conditioner cards can
More informationMODEL: 47LPA. [2] ALARM OUTPUT 0: None 1: N.O. relay contact, 4 points 2: SPDT relay contact, 2 points. Digital Panel Meters 47 Series
Digital Panel Meters 47 Series FREQUENCY INPUT DIGITAL PANEL METER (4½ digit, LED display type) Functions & Features 4 ½ digit digital panel meter 1/8 DIN size Accepts a pulse train input to measure rotation
More informationEC centrifugal fan. backward curved, single inlet
RG56-AG7- ebm-papst Mulfingen GmbH & Co. KG Bachmühle 746 Mulfingen Phone: +49 798 - Fax: +49 798 - www.ebmpapst.com info@de.ebmpapst.com Nominal data Type Motor RG56-AG7- MG-FF Phase ~ Nominal voltage
More informationMIL-Spec Application Guide
Precision tool www.idealind.com 1-800-324-9571 Customer Service MIL-Spec Application Guide Only 5 MDI AIRFRAME TYPE A&B 45-2691 45-2691-1 45-2685 5 MDI HOOK-UP TYPE C 45-2694 45-2694-1 45-2693 45-2692
More informationCCMT 2012 Cutoff List of 4th Round
CCMT 2012 Cut-Off List of 4th round GATE Score Cutoff National Institute of Technology Agartala - (AG) Geotechnical Engineering - (GE) G1 322 281 190 National Institute of Technology Agartala - (AG) Structural
More informationOverview of types. Technical data
echnical data sheet SHA-.. Multifunctional linear actuators for adjusting air dampers and slide valves in ventilation and air-conditioning systems for building services installations For air control dampers
More information(For Rotary Servomotors)
MECHATROLINK-III Communications Reference SERVOPACKs SGDV- E2 (For Rotary Servomotors) Designations S G D V - 2R9 E 2 A 002 00 0 v Series SGDV SERVOPACKs with DC Power Input st+2nd+ 3rd digits 4th digit
More informationMODEL 1450A/02-AH Synthesizer
1450A/02-AH Manual 1/10 MODEL 1450A/02-AH Synthesizer This is a preliminary manual for the Novatech Instruments, Inc. Model 1450A/02-AH Synthesizer. WARNING: Live line voltages are exposed internal to
More information2-Way Proportional Logic Cartridge Valve Model FE.. (Series 1X and 2X) PSI (315 bar) F with electrical connection 12 X Y
RA 9 /6.98 -Way Proportional Logic Cartridge Valve Model FE.. (Series X and X) Size 6... 6... 6 PSI (5 bar)... 75 GPM (8 L/min) RA 9 /6.98 Replaces: 5.9 Characteristics: Single land throttle valve (main
More informationEC centrifugal fan. backward curved, single inlet
RG6-AB6- ebm-papst Mulfingen GmbH & Co. KG Bachmühle 6 Mulfingen Phone: + 798 8- Fax: + 798 8- www.ebmpapst.com info@de.ebmpapst.com Nominal data Type Motor RG6-AB6- MG-IF Phase ~ Nominal voltage [VAC]
More informationMultifunction-Panelmeter
No. SS2-PCM100-0100 Multifunction-Panelmeter Model PCM13 OVERVIEW The PCM13 multifunction-panelmeter receives analog and pulse outputs from flowmeters, pressure gauges, photoelectric switches, etc., and
More informationFeatures. Introduction. Applications. Ordering Information
80/809/80-8/8/-8/8/8-6/6/6/6 Features Precision supply-voltage monitor -.6V (8xxL, 6xL) -.8V (8xxM, 6xM) -.08V (8xxT, 6xT) -.9V (8xxS, 6xS) -.6V (8xxR, 6xR) -.V (8xxZ, 6xZ) -.0V (8xxY, 6xY) 00ms reset
More informationE2F. Cylindrical Proximity Sensor in Plastic Housing. Applications. Ordering Information. Sensors. Accessories (Order Separately)
Cylindrical Proximity Sensor in Plastic Housing High quality full body plastic housing for high water proof requirements Polyarylate housing for light chemical resistance Applications Detection of bottle
More informationDetecting Devices. 8/2 Introduction
Detecting Devices /2 Introduction /4 General data / 3SE5, plastic enclosures /16 3SE2, plastic enclosures /22 3SE5, metal enclosures /30 3SE2, metal enclosures /39 3SE3, metal enclosures Compact design
More informationPower supply voltage Output configuration Output code Resolution (pulses/rotation) Connection method Model
60-mm-dia. Encoder Rugged Encoder for High-precision Detection of Automatic Machine Timing Rugged construction with the highest shaft loading. Radial: 120 N, Thrust: 50 N IP65f water- and oil-proof construction.
More informationEncoders. Series 21 Hollow-Shaft Rotary Optical Encoders Digital incremental or sine/cosine and absolute format. Features & Benefits.
Digital incremental or sine/cosine and absolute format Allied Motion s Series 21 are cost effective, hollow shaft optical encoders that are easy to mount and provide high data rate capabilities. These
More information8WD4 Signaling Columns
Siemens AG 200 General data Overview The 8WD4 signaling columns are flexible in design and versatile in use. 1 1 2 2 3 3 4 5 4 6 8 5 6 10 11 8 12 15 13 14 10 NSC0_002 11 12 NSC0_0026 1 Acoustic element
More informationDetails of Option Specification Code - D012
Specification : D012 Title: Gasket 1/5 Asbestos gaskets cannot be used after 26 April, 2004. Model No. of gasket shall be specified. Precautions for use of metal gaskets Material shall be 304 or better
More informationInput Voltage. Current Draw. Output. Resolution Internal Analog Output. Linearity. Repeatability. Hysteresis +/-.02% of Full Scale. Operating Pressure
BlueOx Magnetostrictive LDT for High Shock and Vibration Areas Gemco brand position sensing products have been known for survival in harsh industrial environments. We have taken over twenty years experience
More informationMSV SEMI. Zener Voltage Regulators. 500 mw SOD 123 Surface Mount. MSZ4678 to MSZ4717 1/6
MSZ4678 to MSZ477 Zener Voltage Regulators 5 mw SOD 3 Surface Mount Three complete series of Zener diodes are offered in the convenient, surface mount plastic SOD 3 package. These devices provide a convenient
More informationSilverMax Datasheet. QuickSilver Controls, Inc. NEMA 23 Servomotors.
SilverMax Datasheet NEMA 23 Servomotors QuickSilver Controls, Inc. www.quicksilvercontrols.com SilverMax Datasheet - NEMA 23 Servomotors 23 Frame Sizes: 23-3, 23-5, 23H-1, 23H-3, 23H-5 / Series: E, E3,
More informationRed: PAINTED ITEMS Blue: KITS IPDA2
Number QTY. DESCRIPTION 73-785 8 SCREW, MX0.7,MM, CPS, CS, BO 73-873 BRKT,DUAL PULLEY Number QTY. DESCRIPTION 7-0 6 PLASTIC,COVER,ACCESSORY RACK 0-93 BOLT M X.75, 30MM HHC HE CS ZP 03-5 3/8" Jam Nut 0-50
More information6ES BE30-0XB0 6ES AE30-0XB0 6ES HE30-0XB0
Overview The compact high-performance CPU With 2 integral input/outputs Expandable by: - 1 signal board (SB) or communication board (CB) - 8 signal modules (SM) - Max. 3 communication modules (CM) Technical
More informationSVAC3. 400W AC Powered Servo Drive. Accessories C IP IP IP C IP. Control Options* For more information, visit:
Feedback E = Encoder board 3 = 3.5A cont, 7.4A peak, 120VA 1.8A cont, 5.4A peak, 220VA ontrol S = Basic version Q = Q Programming = EtherNet/ BLuA5-Si SVA3-S-E120 SVA3-S-E220 SVA3-Q-E120 SVA3-Q-E220 SVA3--E120
More informationGeneral Specifications
General Specifications Signal Conditioner Cards GS 33K50H80-50E OUTLINE Signal Conditioner Cards, which interface to the process, are installed in Signal Conditioner Nests. [Release 5] The signal conditioner
More informationLCD-Module SPECIFICATION
Spec No: 030026 LCD-Module SPECIFICATION Approved by Customer AXBG240128A APPROVED BY CHECKED BY ORGANIZED BY Jeffrey Tina APEX DISPLAY CO., LTD. 1 RECORD OF REVISION Revision Date Page Contents 2003/10/22
More informationConnections Appearance Sensing method Sensing distance Operating mode Model Plug-in connector Horizontal Through-beam 30 m Light-ON
Heavy-duty Plug-in Photoelectric Sensor Water-resistive Photoelectric Sensor with Metal Housing & Plug-in Connector Ensuring Long Sensing Distance Satisfies the requirements of IP67, and NEMA6P. Ensures
More informationRemote Sensor Amplifier Terminal
9 Remote Sensor Amplifier Terminal Plug-in Sensor Amplifiers with Direct CompoBus/S Terminal Connections 1 SRT1 models support only high-speed communications systems 1 4-point terminals expand to 8 points
More informationCorrection Reissue. Product Discontinuation Notices
PRODUCT NEWS Correction Reissue Product Discontinuation Notices January 6, 2014 Pressure Sensors No. 2011265E(2) Discontinuation Notice of Pressure Sensor (Stainless diaphragm) E8AA series (Special product),
More informationSimplified Operations for TM-3100 Series Digital Tachometer
Simplified Operations for TM-3100 Series Digital Tachometer The TM-3100 series Digital Tachometers has the most fundamental function in rotational measurement of four standard models (rotation speed display,
More informationTRD-J Series Incremental Encoders
Series Encoders eatures ong-lasting disign of mm shaft in ø5mm body. urable metal slit plate. Protection degree IP5 (dust proof) or IP65 (dust and splash proof). Wide voltage ranging from 4.75 to 3 VC.
More informationMeasuring systems. 6/2 Built-on optoelectronic rotary encoders 6/2 Introduction
Siemens AG 2008 Measuring systems /2 Built-on optoelectronic rotary encoders /2 Introduction /2 Incremental encoders /3 TTL (RS 422) /3 sin/cos 1 V pp /3 HTL /3 TTL (RS 422) double-track / Absolute encoders
More informationFD423-EA-000 EtherCAT Servo Drive
FEATURES Power Rating of 400-750 Watts 220 VAC Open Network Based on Ethernet RS232 and EtherCAT Supports Modbus 485 and RS232 Communication Protocol Rated Current 4A, Peak Current 15A Supports Pulse +
More informationQR12. Output. A = Line Driver B = Line Driver ABZ/ Open Collector UVW C = Sin/Cos/ Line Driver UVW D = Sin/Cos/Open Collector UVW
QR12 DESIGN FEATURES Low profile assembled height of 0.99" Bearing design simplifies encoder attachment Resolutions up to 20,000 lines per revolution SIN/COS outputs available up to 1250 LC 4, 6 or 8 pole
More informationResolution (divisions) 256, 360, , 360, 720, 1,024 Pre-wired Model
Authorised Distributors:- ASH & ALAIN INDIA PVT LTD S-100, F.I.E.E., Okhla Industrial Area, Phase-ii, New Delhi-110020(India) Tel : 011-4797575 Fax : 011-4797574 E-mail : sales@ashalain.com Absolute 60-mm-dia.
More informationRTD Temperature Sensor omnigrad T -TSM 480, TR 480. Hygienic RTD sensor with Pt 100, class A TSM 480 with electronics programmable via PC
Technical Information TI 273T/02/en 60021667 RTD Temperature Sensor omnigrad T -TSM 480, TR 480 Hygienic RTD sensor with Pt 100, class A TSM 480 with electronics programmable via PC Application The Omingrad
More informationDirectional control valves, direct operated, with electrical position feedback and integrated electronics (OBE)
Directional control valves, direct operated, with electrical position feedback and integrated electronics (OBE) Type 4WRPEH RE 29035 Edition: 2017-04 Replaces: 2015-02 Size 6 Component series 2X Maximum
More informationPROGRAMMABLE CONTROLLER
Shimaden, Temperature and Humidity Control Specialists C %RH Series FP2 PROGRAMMABLE CONTROLLER approved UL applied BASIC FEATURES 2-channel controller (Basic type: 1-channel controller) Independent 2-loop
More informationSURFACE MOUNT ZENER DIODE. VOLTAGE RANGE 2.4 to 43 Volts POWER RATING 500 mwatts
SURFACE MOUNT ZENER DIODE VOLTAGE RANGE 2.4 to 43 Volts POWER RATING 500 mwatts MMSZ468 MMSZ477 FEATURES * Wide Zener Reverse Voltage Range : 2.4V to 43V * 500mW Rating on FR4 or FR5 Board * Small Package
More information847H. Description. Features. Specifications
847H Bulletin 847H High Performance Industrial Incremental Encoders provide code disk resolutions of up to 65536 pulses per revolution at a signal frequency response of 820 khz. The 847H can provide 65536
More informationALUMINUM ELECTROLYTIC CAPACITORS
ALUMINUM ELECTROLYTIC CAPACITORS Trimmed (Cut) or ormed Leads Please refer to page26 about the PCAP product spec. Radial lead type In order to identify correct part number for the processed lead product,
More informationV26 Chassis Part Replacement Instructions Optical Engine Electrical Chassis HDD (PVR) PWB s
2004 V26 Chassis Part Replacement Instructions Optical Engine Electrical Chassis HDD (PVR) PWB s V26 V26+ V26++ WD-52525 WD-52725 WD-52825 WD-62525 WD-62725 WD-62825 MITSUBISHI DIGITAL ELECTRONICS AMERICA,
More informationNX70/NX700 Series Pulse I/O Modules (4CH) (NX70-PULSE4 and NX-PULSE4 ) User Manual
NX70/NX700 Series Pulse I/O Modules (4CH) (NX70-PULSE4 and NX-PULSE4 ) User Manual Important User Information Solid state equipment has operational characteristics differing from those of electromechanical
More information40 mm Beam Pitch General Purpose Area Sensor. Failure monitoring
OTHER SUNX PRODUCTS NA0 SERIES 0 mm Beam Pitch General Purpose Area Sensor Diagnosis Self-diagnosis Interference prevention Slim and intelligent Refer to p.9l for the light curtain. Slim body Failure monitoring
More informationZener Voltage Regulators
Zener Voltage Regulators 5 mw SOD 3 Surface Mount Three complete series of Zener diodes are offered in the convenient, surface mount plastic SOD 3 package. These devices provide a convenient alternative
More informationMotilal Nehru National Institute of Technology Allahabad - (AL) Fluids Engineering - (FE) G
CCMT 2012 Cutoff List of First Round GATE Score Cutoff National Institute of Technology Agartala - (AG) Geotechnical Engineering - (GE) G1 367 330 256 National Institute of Technology Agartala - (AG) Structural
More informationZ4D-F. LED-type Micro Displacement Sensor with Many Features in a Compact Body. Micro Displacement Sensor. Ordering Information.
/ Length Micro Sensor LED-type Micro Sensor with Many Features in a Compact Body Compact body only /4th the volume of our previous product. % cost reduction over our previous product. High performance
More informationOperation. Displayed channel. Measuring range. Status indication/ remote control Key lock Measuring mode/ time constant. Scale.
Electronics & Software Type 5080A... Multichannel Laboratory This universal laboratory charge amplifier can be used for force and torque measurements with piezoelectric dynamometers or force plates. Piezoelectric
More informationPRELIMINARY RE36 SERIES MAGNETIC ENCODER
RE6 SERIES MGNETIC EODER The RE6 is a high-speed rotary magnetic encoder designed for use in harsh environments. The traditional design enables easy integration on existing machines. magnet is mounted
More informationFINDINGS. May 2, Courtney Wilton Portland Public Schools 501 North Dixon Portland, Oregon 97227
May 2, 2017 Courtney Wilton Portland Public Schools 501 North Dixon Portland, Oregon 97227 Via email: Regarding: cwilton@pps.net Lead Paint Condition Assessment Da Vinci Arts Middle School 2508 NE Everett
More informationLD7531 6/25/2008. Green-Mode PWM Controller with Frequency Trembling and Integrated Protections. Features. General Description.
REV: 00 LD7531 6/25/2008 Green-Mode PWM Controller with Frequency Trembling and Integrated Protections General Description The LD7531 is built-in with several functions, protection and EMI-improved solution
More informationTemposonics. R-Series SSI. Absolute, Non-Contact Position Sensors. Temposonics RP and RH Stroke length mm. Perfect data processing 0.
R-Series Temposonics Absolute, Non-Contact Position Sensors R-Series Temposonics RP and RH 25 7600 mm Perfect data processing 0.5 μm Rugged industrial sensor Linear and absolute measurement LEDs for sensor
More informationph or ORP Transmitter
ph or ORP Transmitter Programmable outputs: two transistor and single or dual analog 4-20 ma (Process + Temp) Removable backlighted display Universal process connection Compatible with 120 mm ph/ ORP probes
More informationLCD-Module SPECIFICATION
No: 030027 LCD-Module SPECIFICATION Approved by Customer AXFG240128B APPROVED BY CHECKED BY ORGANIZED BY Jeffrey Tina APEX DISPLAY CO., LTD. 1 RECORD OF REVISION Revision Date Page Contents 2003/10/22
More informationDetecting Devices. 8/2 Introduction
Siemens AG 29 Detecting Devices /2 Introduction 3SE5, 3SE2, 3SE3 Position Switches /4 General data /11 3SE5, plastic and metal enclosures /2 3SE2, plastic enclosures /26 3SE2, metal enclosures /36 3SE3,
More informationNHD WG-BTMI-VZ#
NHD-240128WG-BTMI-VZ# Graphic Liquid Crystal Display Module NHD- Newhaven Display 240128-240 x 128 Pixels WG- Display Type: Graphic B- Model T- White LED Backlight M- STN(-) Blue I- Transmissive, 6:00
More informationLD ma very low quiescent current linear regulator IC. applications. Description. Features SOT23-5L. DFN4 1x1
200 ma very low quiescent current linear regulator IC Datasheet - production data DFN4 1x1 SOT23-5L Applications Mobile phones Personal digital assistants (PDAs) Digital still cameras (DSC) Cordless phones
More informationAll specifications valid at normal input voltage, full load and +25 C after warm-up time unless otherwise stated.
KEY FEATURES U Bracket Switching Power Supply Universal Input: 90-264 VAC Active P.F.C. Function, PF>0.95 300W Convection without FAN 480W Convection with 18CFM FAN Protections: Over Load / Over Voltage
More informationParallel Beam Linear Sensor
Parallel Beam Linear Sensor Visible Red Class II Laser Width/Profile Measurement Sensor Providing High-Speed Precision Measurement with Flexible Operation H FDA Class II IEC Class 2 visible red laser ensures
More informationPowerSource TM 1915 LMM 10 Gb/s Digital Electro-Absorption Laser Module ps/nm Application
TDM and WDM Applications The contains an DFB laser with monolithically integrated electroabsorption modulator (EA-ILM). The modulation voltage is applied to the modulator section while the DFB laser operates
More informationomnigrad T - TSM 480, TR 480. Technical Information. RTD Temperature Sensor Hygienic design TSM 480 with electronics programmable via PC
Technical Information omnigrad T - TSM 480, TR 480 RTD Temperature Sensor Hygienic design TSM 480 with electronics programmable via PC Application areas The onmigrad T easytemp TSM 480 and TR 480 thermometers
More informationSecret Key Systems (block encoding) Encrypting a small block of text (say 128 bits) General considerations for cipher design:
Secret Key Systems (block encoding) Encrypting a small block of text (say 128 bits) General considerations for cipher design: Secret Key Systems (block encoding) Encrypting a small block of text (say 128
More informationAIC1580/L. Step-Down DC/DC Controller with Shutdown FEATURES DESCRIPTION APPLICATIONS
Step-Down DC/DC Controller with Shutdown FEATURES Operation Voltage up to 15V. Simple Voltage-Mode PWM Control. Fast Transient Response. 2V and 1.3V ± 2% Feedback Voltage Reference Option. Adjustable Current
More informationMINIATURE RELAY FOR WIDER APPLICATIONS
TÜV Rheinland HJ MINIATURE RELAY FOR WIDER APPLICATIONS HJ RELAYS FEATURES contact arrangements Form C (for A 0 V AC), Form C (for 0 A 0 V AC)* Excellent contact reliability by Au plating Environmentally
More informationKNC-SRV-FD423 Series Servo Driver
FEATURES Input Voltage Range From 180-264VAC 400-750 Watt Power Range Position, Speed, and Torque Control RS232, RS485 and CAN Requires Single-Loop 17-Bit Magnetic Encoder, Single Lap 20-Bit Communication
More informationDesktop I/O Simulator
Datasheet 36369 Description MotoHawk Control Solutions Desktop I/O Simulator 8909-1043 The 8909-1043 Desktop I/O Simulator is a powerful development tool designed to easily simulate signals to the controller
More informationPhotoelectric Switches for Harsh Environments
Photoelectric Switches for Harsh Environments HP8 Series For even harsher environments Die-cast housing for strength and shock resistance High-performance seal Resistance to the most advanced cutting oils
More informationIncremental encoders With blind or through hollow shaft pulses per revolution programmable
Features Size ø58 mm Precise optical sensing Output signal level programmable (TTL or HTL) Blind or through hollow shaft, ø8 15 mm Connection axial, radial or tangential Pulses per revolution 1...65536,
More information