TABLE OF CONTENTS Designation code

Size: px
Start display at page:

Download "TABLE OF CONTENTS Designation code"

Transcription

1 TLE OF CONTENTS esignation code How to read sensor designations Circuit diagrams Connection according to EN 6097 Sensors Cylinder C Cylinder C/C Square C Square C/C 7 9 utomática Electrónica y Control, S.L. Lacy, 0 cc. 080 Sabadell (arcelona) Tel Fax info@automatica.cat

2 ESIGNTION COE Example: K J M 0 M P S V X = Working principle C H J M N R W coustic cceleration sensor Capacitive Strain gauge sensor Halleffect Inductive JR JF JG J Magnetoresistive Inclination sensor Reedcontact ngle sensor = Switching distance / range = esign G M Q = Housing diameter / edge length Inductive ring Inductive surface Inductive slot Metalface Ring housing Cylindrical housing without thread Cylindrical housing with metrical thread Square housing = Housing material luminium E Stainless steel K Plastic M rass, nickel plated T PTFE 6 = Installation N Shielded Non 7 = Tube length 8 = Operating voltage Z VZ C alternating current voltage C direct current voltage C/C all voltages 9 = Type of output signal N nalog N N P Z NPN Namur PNP Two wire = Function I Ö S U Changeover Impulse output N.C. N.O. Switchable = Termination V V V/ V V V6 V7 V8 V9 V V V VE RS PG Mxx NI NU CN M8 screw/snapin M metal M plastic M metal mphenol Tuchel rad Harrison Valve connector type M8 snapin only Torson Valve connector type C C connector /'' UNF M8 plastic Euchner connector ata interface Thread joint PG Thread joint metrical others as requested = dditional marks M FE HT NF SF T W X Current output Voltage output CNbus interface Sensing face in centre Reduction to steel / iron High temperature Reduction to nonferrous metal Weld field immune Enlarged temperature range ngled sensing face / angled cable exit Customized design with detailled description

3 CIRCUIT IGRMS Circuit diagram for Cable / clamp connection Connector V... V9 PS C PNP N.O. N () K () U () PÖ C PNP N.C. N () K () U () P C PNP changeover N () K () WH () U () PU C NO/NC switchable N () SW () U () NS C NPN N.O. N () K () U () NÖ C NPN N.C. N () K () U () N C NPN changeover N () K () WH () U () NU C NO/NC switchable N () SW () U () N Namur EN N () U () ZS C twowire N.O. N () U () ZÖ C twowire N.C. N () U () ZS/VZS C/C twowire N.O. N () U () GN/YE ZÖ/VZÖ C/C twowire N.C. N () U () GN/YE nalog N () K () U ()

4 CYLINER C General data Operating voltage U b Voltage frequency Voltage drop U d Min. load current I emin Residual current I r Peak current Max. switching frequency f Hysteresis H Operating temperature T a Temperature drift Repeat accuracy R Protection class Switching state EMVstandard Housing material Front cap Connection V C 0/60Hz V m m (0ms / Hz) Hz % C C % % IP67 according to EN6097 brass, nickelplated PCP m cable PVC x 0,mm² The drawings of these sensors are shown on the following page. Other cable lengths as requested. Selection chart rticle number esignation Mounting Output signal Switching distance in mm Max. load current rawing (next page) KJMM70ZS KJMM70ZÖ KJMMN70ZS KJMMN70ZÖ KJM8M60ZS KJM8M60ZÖ KJM8MN60ZS KJM8MN60ZÖ KJM0M60ZS KJM0M60ZÖ KJM0MN60ZS KJM0MN60ZÖ non non non non non non twowire twowire twowire twowire twowire twowire twowire twowire twowire twowire twowire twowire C C E E F F

5 CYLINER C imensions ) 60 ) M x M x C) 0 ) 0 M8 x M8 x E) 0 F) M0 x, M0 x, all data in mm 6

6 CYLINER C/C General data Operating voltage U b Voltage frequency Voltage drop U d Min. load current I emin Max. load current I e Residual current I r Peak current Max. switching frequency f Hysteresis H Operating temperature T a Temperature drift Repeat accuracy R Protection class Switching state EMVstandard Housing material Front cap Connection V C/C 0/60Hz V m 0m (M ),7m (0ms/Hz) 0Hz % C C % % IP67 according to EN6097 brass, nickelplated PCP m cable PVC x 0,mm² The drawings of these sensors are shown on the following page. Short circuit protection and overload protection locking. fter removal of the short circuit the voltage supply has to be interrupted for approximately sec. Other cable lengths as requested. Selection chart rticle number esignation Mounting Output signal Switching distance rawing in mm (next page) KJMM70VZS KJMM70VZÖ KJMMN70VZS KJMMN70VZÖ KJM8M60VZS KJM8M60VZÖ KJ8M8MN60VZS KJ8M8MN60VZÖ KJM0M60VZS KJM0M60VZÖ KJM0MN60VZS KJM0MN60VZÖ non non non non non non twowire twowire twowire twowire twowire twowire twowire twowire twowire twowire twowire twowire 8 8 C C E E F F 7

7 CYLINER C/C imensions ) 60 ) M x M x C) 0 ) 0 M8 x M8 x E) 0 F) M0 x, M0 x, all data in mm 8

8 SQURE C General data Operating voltage U b Voltage frequency Voltage drop U d Min. load current I emin Max. load current I e Residual current I r Peak current Max. switching frequency f Output function Hysteresis H Operating temperature T a Temperature drift Repeat accuracy R Protection class Switching state EMVstandard Housing material Connection KJQ0KZU KJ0Q0KNZU KJ0Q80KNZS V C 0/60Hz V C or C 0/60Hz V C 0/60Hz V V 8V bei 00m m m m 00m m 00m m 00m,8m 8,0 (0ms) Hz twowire changeover 8,0 (0ms) Hz twowire changeover,0 (0ms) Hz twowire changeover % % % C C C C C C % % % % % % IP67 according to EN6097 Trogamide T clamps,mm² IP67 according to EN6097 Trogamide T clamps,mm² IP67 according to EN6097 PT Resin clamps,mm² The drawings of these sensors are shown on the following page. Selection chart rticle number esignations Mounting Switching distance rawing in mm (next page) KJQ0KZU KJ0Q0KNZU KJ0Q80KNZS non non 0 0 9

9 SQURE C imensions ) ) 0 0, 0 7, PG, PG, all data in mm

10 SQURE C/C General data Mounting Operating voltage U b V C /C Voltage frequency 0/60Hz Voltage drop U d V Min. load current I emin m Max. load current I e 00m Residual current I r m Peak current 8 (0ms) Max. switching frequency Hz f Output function twowire changeover Hysteresis H % Operating temperature T a C C Temperature drift % Repeat accuracy R % Protection class IP67 Switching state EMVstandard according to EN 6097 Housing material P 6.6 GF0 Connection clamps,mm² Short circuit protection and overload protection locking. fter removal of the short circuit the voltage supply has to be interrupted for approximately sec. Selection chart rticle number esignation Switching distance rawing in mm KJ0Q0KVZU KJ0Q0KNVZU 0 0 imensions ), 7, 60 PG, all data in mm

TABLE OF CONTENT. Designation code. Circuit diagrams. Functional description. Applications. Sensors. How to read sensor designations

TABLE OF CONTENT. Designation code. Circuit diagrams. Functional description. Applications. Sensors. How to read sensor designations TLE OF CONTENT code How to read sensor designations Circuit diagrams according to EN 609752 Functional description Operating mode of capacitive sensors 5 pplications pplication areas of capacitive sensors

More information

TABLE OF CONTENT Designation code

TABLE OF CONTENT Designation code TBLE OF CONTENT Designation code How to read sensor designations Circuit diagrams Connection according to EN 609752 Sensors Cylinder G Cylinder M Cylinder G Cylinder M5 Cylinder G6,5 Cylinder M8 Square

More information

TABLE OF CONTENT Designation code

TABLE OF CONTENT Designation code TABLE OF CONTENT Designation code How to read sensor designations Circuit diagrams Connection according to EN 0952 Functional description Operating mode of ring sensors 5 Applications Application areas

More information

TABLE OF CONTENTS Designation code Circuit diagrams Functional description Applications Sensors Product overview

TABLE OF CONTENTS Designation code Circuit diagrams Functional description Applications Sensors Product overview TBLE OF CONTENTS Designation code How to read sensor designations 3 Circuit diagrams Connection according to EN 6047-5-2 4 Functional description Operating mode of magnetoresistive sensors 5 pplications

More information

TABLE OF CONTENT Designation code

TABLE OF CONTENT Designation code TABLE OF CONTENT Designation code How to read sensor designations Circuit diagrams Connection according to EN 09752 Functional description Operating mode of ring sensors 5 Applications Application areas

More information

TABLE OF CONTENTS Designation code

TABLE OF CONTENTS Designation code TLE OF ONTENTS Designation code Learn to read sensor designations ircuit diagrams Termination according to EN 975 Sensors Inclination sensors cceleration sensors Tube sensor Overspeed monitor coustic sensor

More information

You find the Pulsotronic everywhere there, where are to set standards and to solve task positions on the far side of well known standing types.

You find the Pulsotronic everywhere there, where are to set standards and to solve task positions on the far side of well known standing types. About us In the traditional and strive industry region ChemnitzZwickau, directly at the freeway A7 you will find the new location of the Pulsotronic GmbH & Co.KG. As a worldwide active company we develop

More information

TABLE OF CONTENT. Designation Code. Selection chart Ranges. Functional description. Applikations. Sensors. Product overview

TABLE OF CONTENT. Designation Code. Selection chart Ranges. Functional description. Applikations. Sensors. Product overview TLE OF CONTENT Designation Code How to read a sensor designations 3 Selection chart Ranges ll sensors at a glance 4 Functional description Functional principle opto-electronic senors 5 pplikations pplication

More information

You find the Pulsotronic everywhere there, where are to set standards and to solve task positions on the far side of well known standing types.

You find the Pulsotronic everywhere there, where are to set standards and to solve task positions on the far side of well known standing types. 08060B060 About us In the traditional and strive industry region ChemnitzZwickau, directly at the freeway A7 you will find the new location of the Pulsotronic GmbH & Co.KG. As a worldwide active company

More information

Type matrix of inductive sensors

Type matrix of inductive sensors Type matrix of inductive sensors 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 13. 14. 15. 16. 17. 18. 19. K I N - T 1 2 N S / 0 0 4 - K L 2 Product group Housing design Output Sensing distance Options 1 K =

More information

E2B PROXIMITY SENSORS

E2B PROXIMITY SENSORS Authorised Distributors:- Intech Systems Chennai Pvt. Ltd, Chennai-00 0 Ph: +9 8888 Fax: 0 7888 E-mail: info@intechchennai.com Website: www.intechchennai.com EB PROIMITY SENSORS A ne w g ener ation in

More information

You find the Pulsotronic everywhere there, where are to set standards and to solve task positions on the far side of well known standing types.

You find the Pulsotronic everywhere there, where are to set standards and to solve task positions on the far side of well known standing types. About us In the traditional and strive industry region ChemnitzZwickau, directly at the freeway A72 you will find the new location of the Pulsotronic GmbH & Co.KG. As a worldwide active company we develop

More information

Electronic Pressure Switch Type MEP

Electronic Pressure Switch Type MEP MAKING MODERN LIVING POSSIBLE Data sheet Electronic Pressure Switch Type MEP MEP 2200 and MEP 2250 versions: Dual output Output : Switch output Hysteresis % FS Time constant ms Output 2: Analogue output

More information

Valve Island with Electronic I/O

Valve Island with Electronic I/O Screw in Temperature /Switch with display for ON/OFF Control Indication, monitoring, transmission and ON/OFF control in one device Extra large display Menu guided parametrisation Complete communication

More information

Induct. Inductive proximity sensors. Inductive sensors. Double sensing range. Triple sensing range. Single sensing range. Flush installation

Induct. Inductive proximity sensors. Inductive sensors. Double sensing range. Triple sensing range. Single sensing range. Flush installation Inductive sensors Inductive proximity sensors Single sensing range Double sensing range Triple sensing range Flush installation Cylinder housing Threaded cylinder housing Cuboid housing Non-flush installation

More information

Interactive Catalog Replaces Catalog Pages

Interactive Catalog Replaces Catalog Pages Interactive Catalog Replaces Catalog Pages Honeywell Sensing and Control has replaced the PDF product catalog with the new Interactive Catalog. The Interactive Catalog is a power search tool that makes

More information

3- and 4-Wire DC 18 mm Diameter Inductive Sensors

3- and 4-Wire DC 18 mm Diameter Inductive Sensors -Wire -Wire - Inductive Sensors 5 to 20 mm sensing ranges 18 mm threaded barrels target indication Cable Micro (M12) quick disconnect models 80-85 for 85-872 for Technical Specifications 18 mm SUPPLY VOLTAGE

More information

ES Series Features Detecting distance twice that of conventional

ES Series Features Detecting distance twice that of conventional Long-distance Separate-amplifier Series Features Detecting distance twice that of conventional sensors Detecting distance easily adjustable Wide range of sensor head types available Built-in alarm output

More information

A finger on the pulse of time

A finger on the pulse of time A finger on the pulse of time F 55 long-range compact light time-of-flight sensors Optical sensors Ultrasonic sensors Inductive sensors Capacitive sensors Vision sensors and systems The multi-talent for

More information

Inductive BEROs. 5/2 Summary of ranges. 5/6 Introduction. 5/20 Operating distance 0.6 mm. 5/20 Operating distance 0.8 mm. 5/22 Operating distance 1 mm

Inductive BEROs. 5/2 Summary of ranges. 5/6 Introduction. 5/20 Operating distance 0.6 mm. 5/20 Operating distance 0.8 mm. 5/22 Operating distance 1 mm /2 Summary of ranges /6 Introduction /20 Operating distance 0.6 mm /20 Operating distance 0.8 mm /22 Operating distance 1 mm /24 Operating distance 1. mm /28 Operating distance 2 mm /34 Operating distance

More information

SW 16mm. SW 15mm. SW 19mm

SW 16mm. SW 15mm. SW 19mm M B-Coding Automation Technology 7 series Screw locking acc. to DIN EN 6076--0 Degree of protection IP67 Moulded versions Degree of protection IP68 Easy assembly Excellent EMC shielding Versions with shielding

More information

This kind of information is useful to make reliable automatic control diagnostic and supervision systems. IS VS. Diameter of cylindrical types

This kind of information is useful to make reliable automatic control diagnostic and supervision systems. IS VS. Diameter of cylindrical types HOW TO INTERPRETE THE ACCELERATION SENSORS Acceleration is a physical quantity related to any event of motion, rotation, vibration and inclination. Monitoring accelerations is an optimal way to gather

More information

Mineral-insulated resistance thermometers to EN

Mineral-insulated resistance thermometers to EN Data Sheet 90.2221 Page 1/6 Mineral-insulated resistance thermometers to EN 60 751 for temperatures from -50 (-200) to +600 C flexible sheath with shock-protected sensor as single or twin resistance thermometer

More information

Highlights. SIMATIC PXI inductive proximity switches. Introduction. Inductive proximity switches rugged, accurate and reliable

Highlights. SIMATIC PXI inductive proximity switches. Introduction. Inductive proximity switches rugged, accurate and reliable Siemens G 008 SIMTIC PXI inductive proximity switches Introduction Inductive proximity switches rugged, accurate and reliable PXI series The inductive proximity switches are organized in different product

More information

Capacitive levels controllers

Capacitive levels controllers Capacitive levels controllers for automatic control, regulation and signalling of levels of conductive and non-conductive liquids or pourable bulk goods Jola Spezialschalter GmbH & Co. KG Klostergartenstr.

More information

Inductive switches. Dimensioned drawing

Inductive switches. Dimensioned drawing IS 212 Inuctive switches Dimensione rawing IS 212-2E0-S12 IS 212-4E0-S12 IS 212-6E0-S12 en 02-2010/03 50110220 2mm 4mm 6mm 10-30 V DC 3 khz Embee Slim an short cylinrical metal housing M12 Chromium-plate

More information

NEW. Automation Technology 768 series

NEW. Automation Technology 768 series Automation Technology 78 series Screw locking acc. to DIN EN 07--0 Degree of protection IP7 Moulded versions Easy Assembly Excellent EMC shielding (versions with shielding rings 0 ) Versions with shielding

More information

E2F. Cylindrical Proximity Sensor in Plastic Housing. Applications. Ordering Information. Sensors. Accessories (Order Separately)

E2F. Cylindrical Proximity Sensor in Plastic Housing. Applications. Ordering Information. Sensors. Accessories (Order Separately) Cylindrical Proximity Sensor in Plastic Housing High quality full body plastic housing for high water proof requirements Polyarylate housing for light chemical resistance Applications Detection of bottle

More information

Conductivity Transmitter

Conductivity Transmitter Conductivity Transmitter Programmable outputs: two transistor and single or dual analog 4-20 ma Removable backlighted display Universal process connection Type can be combined with... Three cell constants

More information

DMP 343. Industrial Pressure Transmitter. Without Media Isolation. accuracy according to IEC 60770: 0.35 % FSO. Nominal pressure

DMP 343. Industrial Pressure Transmitter. Without Media Isolation. accuracy according to IEC 60770: 0.35 % FSO. Nominal pressure DMP 4 Industrial Pressure Transmitter Without Media Isolation accuracy according to IEC 60770: 0.5 % FSO Nominal pressure from 0... 0 mbar up to 0... 000 mbar Product characteristics excellent linearity

More information

ph or ORP Transmitter

ph or ORP Transmitter ph or ORP Transmitter Programmable outputs: two transistor and single or dual analog 4-20 ma (Process + Temp) Removable backlighted display Universal process connection Compatible with 120 mm ph/ ORP probes

More information

Digital flow ELEMENT transmitter for continuous flow measurement

Digital flow ELEMENT transmitter for continuous flow measurement Digital flow ELEMENT transmitter for continuous flow measurement Type 8036 can be combined with... DN06 to DN65 fluidic process connection Programmable outputs : one or two transistor output(s) and single

More information

Digital flow ELEMENT transmitter for continuous flow measurement

Digital flow ELEMENT transmitter for continuous flow measurement ELEMENT Transmitter Digital flow ELEMENT transmitter for continuous flow measurement Type can be combined with... PN10, DN15 to DN400 fluidic process connection Programmable outputs : one or two transistor

More information

I Kanson Electronics, Inc.

I Kanson Electronics, Inc. Courtesy of Steven Engineering, nc. 230 Ryan Way, South San Francisco, CA, 94080-6370 Main Office: (650) 588-9200 Outside Local Area: (800) 258-9200 www.stevenengineering.com MODEL 1221 LMT STYLE DC Limit

More information

Limit Switch Style Inductive Prox

Limit Switch Style Inductive Prox Limit Switch Style Inductive Prox Economical, Limit Switch Style Sensor with Plastic Body Low cost Wide operating voltages (10 to 0 VDC and 90 to 250 VAC) Directly switches AC loads up to 500 ma, DC loads

More information

DMP 343. Industrial Pressure Transmitter. Without Media Isolation. appmeas.co.uk +44 (0)

DMP 343. Industrial Pressure Transmitter. Without Media Isolation. appmeas.co.uk +44 (0) DMP 4 Industrial Pressure Transmitter Without Media Isolation accuracy according to IEC 60770: 0.5 % FSO Nominal pressure from 0... 0 mbar up to 0... 000 mbar Product characteristics excellent linearity

More information

P R o D u c T I n F o R m at I o n. TDR Level Sensor LFP. The clean solution

P R o D u c T I n F o R m at I o n. TDR Level Sensor LFP. The clean solution P R o D u c T I n F o R m at I o n TDR Level Sensor The clean solution Level sensors The clean solution Product description The is a hygienic level sensor for liquids using TDR technology a process for

More information

Ultrasonic sensors. Reliable on almost all surfaces. UT 20 from Page 548. UT 12 from Page 564. UT/UM 18 from Page 568

Ultrasonic sensors. Reliable on almost all surfaces. UT 20 from Page 548. UT 12 from Page 564. UT/UM 18 from Page 568 Ultrasonic sensors Reliable on almost all surfaces UT 0 from Page 58 UT from Page 56 UT/UM 8 from Page 568 UT 0-S miniature ultrasonic sensors with soundpipe Reliable detection through the smallest of

More information

RTD Temperature Sensor omnigrad T -TSM 480, TR 480. Hygienic RTD sensor with Pt 100, class A TSM 480 with electronics programmable via PC

RTD Temperature Sensor omnigrad T -TSM 480, TR 480. Hygienic RTD sensor with Pt 100, class A TSM 480 with electronics programmable via PC Technical Information TI 273T/02/en 60021667 RTD Temperature Sensor omnigrad T -TSM 480, TR 480 Hygienic RTD sensor with Pt 100, class A TSM 480 with electronics programmable via PC Application The Omingrad

More information

METAL-BODIED LIMIT SWITCHES: SN6 SERIES

METAL-BODIED LIMIT SWITCHES: SN6 SERIES METAL-BODIED LIMIT SWITCHES: SN6 SERIES Features: Aluminum body and lid Mounting Advantages: Snap action or slow make & break contacts Increased wiring space Galvanically separated contacts Screw terminals

More information

Phone: Fax: Web: -

Phone: Fax: Web:  - ue to their sturdy bearing construction in Safety-ock esign, the Sendix 5000 and 500 offer high resistance against vibration and installation errors. The rugged housing, high protection level of up to

More information

Diameter (mm) Sinking. Sourcing. Drawing # Wiring Diagram # of LEDs. Ni75U-CP80-AN6X A M

Diameter (mm) Sinking. Sourcing. Drawing # Wiring Diagram # of LEDs. Ni75U-CP80-AN6X A M Courtesy of Steven Engineering, Inc. 30 Ryan Way, South San Francisco, C, 940-6370 Main Office: (650) 588-900 Outside Local rea: (0) 58-900 www.stevenengineering.com TURCK Inductive Sensors - Rectangular

More information

INSERTION paddle wheel flowmeter for continuous flow measurement

INSERTION paddle wheel flowmeter for continuous flow measurement INSERTION paddle wheel flowmeter for continuous flow measurement Economic integration in pipe systems without any additional piping 3-wire frequency pulse version to directly interface with PLC s (both

More information

Mechatronic pressure measurement. Applications. Special features. Description

Mechatronic pressure measurement. Applications. Special features. Description Mechatronic pressure measurement Diaphragm pressure gauge with electrical output signal For the process industry High overload safety up to the 10-fold full scale value, max. 40 bar Models PGT43.100 and

More information

PD30CNB25xxPS. Photoelectrics, Background suppression reflective - PointSpot. Main features. Main functions. Description

PD30CNB25xxPS. Photoelectrics, Background suppression reflective - PointSpot. Main features. Main functions. Description Photoelectrics, Background suppression reflective - PointSpot Main features Miniature sensor range The visible red PointSpot light makes alignment very easy Range: 250 mm Sensitivity adjustment by potentiometer

More information

Level and Pressure. Product Information. Vibrating level switches

Level and Pressure. Product Information. Vibrating level switches Level and Pressure Product Information Vibrating level switches Contents Contents 1 Product description 1.1 VEGAVIB... 3 1.2 VEGASWING... 3 2 Function and application 2.1 Functional principle... 5 2.2

More information

FOR RELIABLY MEASURING +

FOR RELIABLY MEASURING + in(f)a22 ina05-09 ina14 PROXIMITY SWITCHES FOR RELIABLY MEASURING + EVALUATING MOVEMENTS T H E PROXIMITY SWITCHES O F T I E F E N B A C H C O N T R O L S Y S T E M S >>> HAVE BEEN ESPECIALLY DEVELOPED

More information

XXXX e. X d.. X X X a

XXXX e. X d.. X X X a The Heavy uty incremental encoder type 0H boasts a high degree of ruggedness in a very compact design. Its special construction makes it perfect for all applications in very harsh environments. / RoHS

More information

NGR. Guided Wave Radar Level Transmitter

NGR. Guided Wave Radar Level Transmitter Guided Wave Radar Level Transmitter measuring monitoring analyzing NGR For Liquids Operates Independent of Density, Temperature, Pressure, Humidity, and Conductivity Standard Measuring Length: 6. Ft (Longer

More information

Medium-base Lampholders

Medium-base Lampholders Medium-base Lampholders For HID Lamps Medium-base lampholders Material: porcelain, white Nominal rating: 4A/250V/5kV pulse rated Terminals: bushings with set screws 18 14AWG solid Screw shell insert: zinc-plated

More information

Process Protection Acoustic sensors for pump monitoring

Process Protection Acoustic sensors for pump monitoring coustic sensors for pump monitoring acoustic diagnostic unit Overview The acoustic diagnostic unit acoustically measures the structure-borne noise In the version for pump monitoring; on oscillating displacement

More information

TURCK Inc Campus Drive Minneapolis, MN Application Support: PROX Fax: (763)

TURCK Inc Campus Drive Minneapolis, MN Application Support: PROX Fax: (763) A Sensor Designed with the Customer Applications in Mind! High Accuracy The PS400 and PS500 provide an accuracy rating of ±0.5 percent of the full scale. Flexible Mounting Options Multiple threaded connections

More information

Float switch For industrial applications, plastic version Model RLS-2000

Float switch For industrial applications, plastic version Model RLS-2000 Level measurement Float switch For industrial applications, plastic version Model RLS-2000 WIKA data sheet LM 50.04 Applications Level measurement of liquids in machine building Control and monitoring

More information

Standard Sendix 5000 / 5020 (shaft / hollow shaft) Push-Pull / RS422 / Open collector. Robust performance. Many variants

Standard Sendix 5000 / 5020 (shaft / hollow shaft) Push-Pull / RS422 / Open collector. Robust performance. Many variants ue to their sturdy bearing construction in Safety-ock esign, the Sendix 5000 and 500 offer high resistance against vibration and installation errors. The rugged housing, high protection level of up to

More information

Fibre-optic units SOE4

Fibre-optic units SOE4 Product overview Product overview Version Type Type of display Timer function Switching output Analogue output Page/Internet Fibre-optic unit SOE4-FO-L LED PNP NPN SOE4-FO-D LED display 1 2000 ms PNP NPN

More information

Inductive Linear Position Sensor IO-Link LI100P0-Q25LM0-ELIUPN8X3-H1151

Inductive Linear Position Sensor IO-Link LI100P0-Q25LM0-ELIUPN8X3-H1151 Rectangular, aluminium / plastic Versatile mounting possibilities Measuring range indicated via LED Immune to electromagnetic interferences Extremely short blind zones Programmable measuring range 16 bit

More information

housing length L2 mm -U B (pole reversal protection)

housing length L2 mm -U B (pole reversal protection) SM41eng /Nordic Transducer Denmark 2.0 / 12.10 www.ntt.dk Inductive Displacement Transducer Series SM41 / SM43 Programmable Inductive Transducer The analogue signal of an inductive sensor is digitised

More information

Flow Meter FC100. Description FC100. Ordering information

Flow Meter FC100. Description FC100. Ordering information Flow Meter FC00 Microcontroller operated Flow Meter to monitor and display flow rates and temperature. Once correctly adjusted it can also be used for mass flow measurements. Factory preset for air and

More information

Long-distance Separate-amplifier Proximity Sensors ES Series Features Detecting distance twice that of conventional

Long-distance Separate-amplifier Proximity Sensors ES Series Features Detecting distance twice that of conventional Long-distance Separate-amplifier ES Series Features Detecting distance twice that of conventional sensors Detecting distance easily adjustable Wide range of sensor head types available Built-in alarm output

More information

Optimising controls Vacuum switches

Optimising controls Vacuum switches Vacuum switches, pneumatic Converts a vacuum level to a pneumatic signal. Vacuum-actuated membrane linked to a pneumatic switch. Available preset or with adjustable vacuum level. Unit Value Feed pressure,

More information

Paddle wheel flow controller for On/Off control

Paddle wheel flow controller for On/Off control addle wheel flow controller for On/Off control Type 8032 compact Type 8032 can be combined with... Type 8032 remote Indication, monitoring, transmitting and On/Off control in one device. rogrammable outputs

More information

Cylindrical Photoelectric Sensor. 6. Connection F Sensing Distance. 100: 100 mm. 300: 300 mm 2M: 2 Meters 5M: 5 Meters. 5. Output NPN - NO, NC

Cylindrical Photoelectric Sensor. 6. Connection F Sensing Distance. 100: 100 mm. 300: 300 mm 2M: 2 Meters 5M: 5 Meters. 5. Output NPN - NO, NC Cylindrical Sensor Proximity SALIENT FEATURES Metal Housing AC 2wire- NO, NC DC 3 Wire- NPN, PNP DC Dual Output Models Upto 5 m sensing distance Diffuse, Retro, Through Beam Measurement Model Number Legend

More information

OEM pressure sensor For industrial applications Models O-10 (T), O-10 (5)

OEM pressure sensor For industrial applications Models O-10 (T), O-10 (5) Pressure OEM pressure sensor For industrial applications Models O-10 (T), O-10 (5) WIKA data sheet PE 81.65 for further approvals see page 11 Applications Hydraulics and pneumatics Pumps and compressors

More information

Pharma Temperature Sensor G3/8"

Pharma Temperature Sensor G3/8 1 Product Information TFP-58P, -68P, -168P, -188P Pharma Temperature Sensor G3/8" P H A R M A Application / Specified Usage Aseptic temperature measurement, inline, high precise and fast without product

More information

T40B. Torque Flange. Special features. Data sheet. Overall concept

T40B. Torque Flange. Special features. Data sheet. Overall concept T40B Torque Flange Special features - Nominal (rated) torques 50 N m, 0 N m, 200 N m, 500 N m, 1 kn m, 2 kn m, 3 kn m, 5 kn m and kn m - Nominal rated rotational speed up to 24000 rpm (depending on nominal

More information

Absolute pressure gauge with output signal For the process industry Models APGT and APGT43.160, NS 100 and 160

Absolute pressure gauge with output signal For the process industry Models APGT and APGT43.160, NS 100 and 160 Mechatronic pressure measurement Absolute pressure gauge with output signal For the process industry Models APGT43.100 and APGT43.160, NS 100 and 160 k Applications for further approvals see page 4 WIKA

More information

NAT Applications. Features

NAT Applications. Features NAT 85 Industrial Pressure Transmitter Swiss based Trafag is a leading international supplier of high quality sensors and monitoring instruments for measurement of pressure and temperature. The industrial

More information

XXXX e. X d.. X X X a

XXXX e. X d.. X X X a The Heavy Duty incremental encoder type 0H boasts a high degree of ruggedness in a very compact design. Its special construction makes it perfect for all applications in very harsh environments. / RoHS

More information

INLINE flowmeter for continuous flow measurement

INLINE flowmeter for continuous flow measurement INLINE flowmeter for continuous flow measurement Economic integration in pipe systems without any additional piping 3-wire frequency pulse version to directly interface with PLC s (both PNP and NPN) Connection

More information

Absolute Encoders - Singleturn

Absolute Encoders - Singleturn The Sendix 5 and Sendix 7 singleturn encoders with SSI or BiSS-C interface and optical sensor technology can achieve a resolution of max. 7 bits. These encoders are also available with an optional SinCos

More information

Micro Power Inductive Proximity Sensor L1T3M Series 4 µa Operating Current +2.5V DC Industry s Lowest

Micro Power Inductive Proximity Sensor L1T3M Series 4 µa Operating Current +2.5V DC Industry s Lowest Mercury Sensor Products Quick Selection Guide Technology: Inductive. Responsive to metal proximity. Output Options: Normally Closed or Normally Open Output Type: NMOS switching. Connection: Cable leads.

More information

Photoelectric Sensors Standard

Photoelectric Sensors Standard Contents Standard Tubular.2 BOS 08M M8 metal.6 BOS 12M M1etal.14 M18 metal with potentiometer Rugged with teach-in Laser with AC voltage with angle head.36 BOS 18E M18 stainless steel.42 BOS 18KF M18 plastic

More information

TONGFENG FLEXIBLE CONDUIT TONGFENG FLEXIBLE CONDUIT

TONGFENG FLEXIBLE CONDUIT TONGFENG FLEXIBLE CONDUIT TONGFENG FLEXIBLE CONDUIT TONGFENG FLEXIBLE CONDUIT 1 COMPANY BREIF INDRODUCTION TONGFENG Products --- Your Professional Electrical Wiring Protection Solutions. As an industrial leader, the company offers

More information

Quality Normal steel chrome-plated, Scale glare-free matt-chrome-plated. Quality Normal steel chrome-plated, Scale glare-free matt chrome-plated.

Quality Normal steel chrome-plated, Scale glare-free matt-chrome-plated. Quality Normal steel chrome-plated, Scale glare-free matt chrome-plated. 37006 Bevel protractors 0 - With degree graduation 0-180 and locking screw Normal steel chrome-plated, Scale glare-free matt-chrome-plated. 37006 Measuring/ Arc Ø Blade length 37006 80 120 101 120 150

More information

Precision Universal Bevel Protractor, Set

Precision Universal Bevel Protractor, Set ß 37006 Protractors Measuring and laying-out tools, gauges 0 With 0-180 scale and locking screw. Standard steel, chrome-plated, scale dazzle-free and with matt-chromed finish. 37006 Arc Length of 37006...

More information

Step Step. Step. Step. Step

Step Step. Step. Step. Step Steps f selecting the appropriate proximity switch The purpose of this selection process is to determine which switch type is best suited to the application. This depends on the material properties of

More information

Fibre-optic sensors and cables

Fibre-optic sensors and cables -optic sensors and cables -optic sensors and fibre-optic cables for a wide range of applications FL 0 from Page 446 -optic sensor in miniature housing for installation in restricted spaces Simple and reliable

More information

NAT Applications. Features

NAT Applications. Features NAT 85 Industrial Pressure Transmitter Swiss based Trafag is a leading international supplier of high quality sensors and monitoring instruments for measurement of pressure and temperature. The industrial

More information

Incremental Encoder for special applications

Incremental Encoder for special applications Model Number Features Up to 50,000 ppr Extended temperature range Industrial standard housing Ø58 mm Servo or clamping flange 10 V... 30 V with short-circuit proof push-pull output Description High performance

More information

High Accuracy Positioning Sensors EG Series Features

High Accuracy Positioning Sensors EG Series Features High ccuracy Positioning s EG Series Features Ultra-small sensor head Non-contact, stable detection in wide temperature range Highly stable amplifier provides 1 µm. Mil repeatability Hi/Lo tolerance detection

More information

Inductive switches. Dimensioned drawing

Inductive switches. Dimensioned drawing IS 244 Inuctive switches Dimensione rawing en 01-2010/11 50114422 20mm 10-30 V DC 150 Hz embee Plastic 40 x40mm cubical housing Connection via screw terminals Built-in short circuit protection, polarity

More information

Micro-Change. Cordset Family

Micro-Change. Cordset Family Side Tab Cordset Family Small Space? Big Solution. When space and time are in short supply, look no further than Brad Harrison brand for the best, ready-made m connector solutions. For fast, compact migration

More information

omnigrad T - TSM 480, TR 480. Technical Information. RTD Temperature Sensor Hygienic design TSM 480 with electronics programmable via PC

omnigrad T - TSM 480, TR 480. Technical Information. RTD Temperature Sensor Hygienic design TSM 480 with electronics programmable via PC Technical Information omnigrad T - TSM 480, TR 480 RTD Temperature Sensor Hygienic design TSM 480 with electronics programmable via PC Application areas The onmigrad T easytemp TSM 480 and TR 480 thermometers

More information

Absolute encoders multiturn

Absolute encoders multiturn The Sendix M6 with Energy Harvesting Technology is an electronic multiturn encoder in miniature format, without gear and without battery. With a size of just 6 x 5 mm it offers a blind hollow shaft of

More information

Miniature resistance thermometer Explosion-protected version Model TR34, thread-mounted

Miniature resistance thermometer Explosion-protected version Model TR34, thread-mounted Electrical temperature measurement Miniature resistance thermometer Explosion-protected version Model TR34, thread-mounted WIKA data sheet TE 60.34 Applications Machine building, plant and vessel construction

More information

FEATURES. 15 m ft. 4 m ft. 2 m ft. 100 mm in. 600 mm in. 15 m ft. 4 m ft. 2 m ft. 100 mm 3.

FEATURES. 15 m ft. 4 m ft. 2 m ft. 100 mm in. 600 mm in. 15 m ft. 4 m ft. 2 m ft. 100 mm 3. 273 Cylindrical Photoelectric Sensor SERIES Related Information General terms and conditions... F-3 Glossary of terms... P.1549~ guide... P.231~ General precautions... P.1552~ PHOTO PHOTO MEASURE -LS200

More information

Screw-in resistance thermometers with plug connector

Screw-in resistance thermometers with plug connector Data Sheet 90.2004 Page 1/7 s with plug connector for temperatures from -50 to +300 C highly resistant to shock and vibration connector locked in for reliable contact, IP65 or IP69K protection available

More information

Temposonics. Magnetostrictive Linear Position Sensors. GB-M / GB-T Analog Data Sheet

Temposonics. Magnetostrictive Linear Position Sensors. GB-M / GB-T Analog Data Sheet Temposonics Magnetostrictive Linear Position Sensors GB-M / GB-T Analog Sensor element and electronics can be changed Flat & compact sensor electronics housing Electrical connection is freely rotatable

More information

Products catalogue (I-P Edition)

Products catalogue (I-P Edition) Products catalogue (I-P Edition) Products catalogue (I-P Edition) FROM QUALITY OUR NATURAL DEVELOPMENT Active in the industry of Refrigeration and Air Conditioning for fifty-five years, Castel is well-established

More information

PD30ETB20xxIS. Photoelectrics, Background Suppression reflective with IR light. Main features. Description

PD30ETB20xxIS. Photoelectrics, Background Suppression reflective with IR light. Main features. Description Photoelectrics, Background Suppression reflective with IR light Main features Description The PD30ET... stainless steel sensors are built with high-quality materials and designed for harsh environments.

More information

Inductive Proximity Sensor

Inductive Proximity Sensor Authorised Distributors:- Intech Systems Chennai Pvt. Ltd, Chennai-600 032 Ph: +91 44 4353 8888 Fax: 044 4353 7888 E-mail: info@intechchennai.com Website: www.intechchennai.com distance Supply voltage

More information

SHORTFORM CATALOGUE. DIN EN Reg.-No. DAT-P-048/ Testing laboratory accredited according to

SHORTFORM CATALOGUE. DIN EN Reg.-No. DAT-P-048/ Testing laboratory accredited according to SHORTFORM CATALOGUE Registration No.: 1327-01 Testing laboratory accredited according to DIN EN 45001 Reg.-No. DAT-P-048/95-00 For all transactions, the newest version of the General Conditions of Sale

More information

Temposonics. Magnetostrictive Linear Position Sensors. GB Analog Data Sheet

Temposonics. Magnetostrictive Linear Position Sensors. GB Analog Data Sheet Temposonics Magnetostrictive Linear Position Sensors GB Analog High pressure resistant sensor rod High operating temperature up to +100 C (+212 F) Flat & compact ideal for the valve market MEASURING TECHNOLOGY

More information

INLINE flowmeter for continuous flow measurement

INLINE flowmeter for continuous flow measurement INLINE flowmeter for continuous flow measurement Economic integration in pipe systems without any additional piping 3-wire frequency pulse version to directly interface with PLC s (both PNP and NPN) Connection

More information

Retro-Reflex Sensors. Application examples:

Retro-Reflex Sensors. Application examples: Retro-Reflex Sensors In retro-reflex sensors, the transmitter and receiver are located in a single housing. They operate using red light, laser light and a reflector. The output switches if the light beam

More information

Measuring and Controlling Unit Multronic OC

Measuring and Controlling Unit Multronic OC Measuring and Controlling Unit Multronic OC One channel measuring and controlling unit for ph / conductivity / Chlorine measuring Automatic temperature compensation Measuring and control behaviour simultaneously

More information

Digital conductivity transmitter

Digital conductivity transmitter Digital conductivity transmitter Compact version with integrated conductivity electrodes Remote version with seperated transmitter for short (15 ft.) or long (1500 ft.) distance Commissioning is easy due

More information

Inductive sensor BI2-Q4,7-AN6X

Inductive sensor BI2-Q4,7-AN6X BI2-Q4,7-AN6X Rectangular, height 4.7 mm Active face on top Metal housing, GD-ZnAI DC 3-wire, 10 30 VDC NO contact, NPN output Cable connection Wiring diagram Type code BI2-Q4,7-AN6X Ident-No. 1614001

More information

Universal process controller econtrol

Universal process controller econtrol 8 Universal process controller Type 8 can be combined with... Continuous, point, point and On/Off control Ratio control function Sensor inputs (,, frequency, RTD) Control of proportional, process and motor

More information

Temperature Sensor with Thread G1/4" FLEXadapt

Temperature Sensor with Thread G1/4 FLEXadapt SENSORS FOR FOOD AND BIOPHARMA. Product Information TFP-414, -614, -814 FOOD Temperature Sensor with Thread G1/4" FLEXadapt Application/Specified usage Temperature measurement in weld-in thermowells and

More information