FOUR CATEGORIES OF SAFETY
|
|
- Liliana Blair
- 5 years ago
- Views:
Transcription
1 OCTOBER 2013
2 FOUR CATEGORIES OF SAFETY DOSIMETRY PERSONAL SAFETY EQUIPMENT EQUIPMENT KNOWLEDGE PHYSICAL SAFETY
3 DOSIMETRY THERMAL LUMINISCENT DEVICES AND FILM BADGES
4 CNSC PERMISSIBLE DOSES WHOLE BODY DOSE 20mSV/Yr WITH A LIMIT OF 100mSV OVER 5 YEARS 50mSV ANY GIVEN YEAR WITHIN A 5 YEAR PERIOD STILL NOT TO EXCEED 100mSV EXTREMITY DOSE 140mSV/Yr
5 GENERAL PUBLIC 1mSV/Yr BACKGROUND RADIATION CANADIAN AVERAGE 2.2 msv/yr OTTAWA 2.8mSV/Yr
6 RADIATION PROTECTION BUREAU REQURIES THAT HEALTH CARE WORKERS BE MONITORED WHEN THEY ARE WORKING WITH RADIATION CLASSIFIED AS AN X RAY WORKER LEGALLY RECEIVE TWENTY (FIFTY) TIMES THE WHOLE BODY YEARLY DOSE THAT THE GENERAL PUBLIC CAN RECEIVE HOW MUCH WILL YOU ACTUALLY RECEIVE?
7 TLD/FILM BADGES CHANGED QUARTERLY RESULTS SENT TO THE RADIATION PROTECTION OFFICE AND TO THE WORK AREA EXPECTED QUARTERLY DOSE FOLLOWING SAFE PRACTICES WHOLE BODY/TORSO ONE msv HEAD/COLLAR ONE TWO msv
8 QUARTERLY READING ELEVATED ALLOWS FOR REVIEW OF SAFETY PRACTICES AND MAKE YOUR WORK ENVIROMENT SAFER FOR YOU LIFE LONG REGISTRY FOR THE AMOUNT OF RADIATION RECEIVED (FOLLOWS ACROSS CANADA AND CAN BE SENT TO OTHER COUNTRIES)
9 PERSONAL SAFETY EQUIPMENT
10 MANY STYLES OF LEAD APRONS ONE PIECE, TWO PIECE, HALF, WRAP AROUND LITE APRONS ULTRA LITE APRONS NON LEAD RARE EARTH APRONS
11 PROVINCE REGULATES WHAT IS A SAFE APRON MOST COMMON: 0.5 mm of lead in the front and 0.25 mm of lead in the back RADIATION ATTENUATION 90% at 120 kv 93 % at 100 kv 96% at 80 kv
12 NON LEAD RARE EARTH RADIATION ATTENUATION 76% at 120 kv 85% at 80 kv THE KV RANGE DURING FLUOROSCOPY kv THE KV RANGE DURING SERIAL MULTI FRAME IMAGING kv
13 THYROID SHIELD 0.5 mm OF LEAD SAME RADIATION ATTENUATION AS THE LEAD APRON
14 LEAD GLASSES NO REGULATIONS ON THE AMOUNT OF LEAD FOR ATTENUATION RECOMMEND 0.75 mm
15 MAINTAINING PROTECTION HANG UP YOUR APRON DO NOT SIT ON OR FOLD YOUR APRON HAVE THE APRON INSPECTED YEARLY CLEAN THE APRON PROPERLY
16
17
18 SHIELDING
19 SHIELDING
20 EQUIPMENT KNOWLEDGE WHAT ARE YOU USING IMAGE INTENSIFIER OR FLAT PLATE DECTECTOR SYSTEM WHAT ARE YOUR R VALUES WHAT ARE YOUR CINE/IMAGING SETTINGS
21 FLOOR MOUNTED SINGLE PLANE
22 CEILING MOUNTED SINGLE PLANE
23 C ARM IMAGE INTENSIFIER
24 INVERSE SQUARE LAW
25
26 EXPOSED PROCEDURE ROOM ELECTROPHYSIOLOGY SUITES CATHERIZATION SUITES MOBILE X RAYS BEDSIDE PROCEDURES OPERATING ROOMS
27 SAFETY MEASURES EQUIPMENT PURCHASES EQUIPMENT MODIFICATIONS EXPOSURE REDUCTION SOFTWARE PROGRAMMED DEFAULTS PREVENTATIVE MAINTENANCE QUALITY ASSURANCE PROGRAM TLD REVIEW RADIATION SAFETY OFFICE EDUCATION
28 FLUOROSCOPY AND CINE ALARA PRINCIPLE Use a pulsed fluoroscopy 3 15 fps Choose a low dose fluoroscopy setting kv ma
29 PROJECTION AND DOSE RAO RAO CRANIAL AND CAUDAL ANGULATION LAO LAO CRANIAL AND CAUDAL ANGULATION LATERAL LEFT AND RIGHT
30 Whenever possible use the store fluoro or image grab function Last image hold Use a cine rate of 15 fps (can be set to 30 fps) kv ma Single image whenever possible instead of cine
31 Use a larger detector size such as cm to acquire the cine image and use digital magnification to enlarge the image With a flat plate detector the 20 cm size requires 6 % more radiation than the 25 cm detector resulting in more scatter With an image intensifier the 6 inch requires 50% more radiation than the 9 inch
32 COLLIMATION and FILTERS Position the detector or image intensifier as close as possible to the patient Use the collimators to frame the picture Place the filters to even out the density reduce the bright spots
33
34
35 TIPS TO REDUCE DOSE Use technology that is available to be able to reduce patient and staff dose (also yours) Dual axis rotational angiography can reduce the patients cine dose by 75 % Single plane rotational angiography can reduce the cine dose by 15% By using last image hold the shutters and filters can be positioned without using fluoroscopy Auto positioning programs position the c arm, move in the detector, also set the shutters and filters
36 SINGLE PLANE ANGIOGRAPHY
37 DUAL AXIS ROTATIONAL
38 PHYSICAL SAFETY WEAR YOUR LEAD APRON NOT LOOKING AT THE LIVE MONITOR DO NOT FLUORO PLEASE DO NOT HIT THE PATIENT AND STAFF WITH THE FLAT PLATE DETECTOR OR THE C ARM
Philips XPER FD10C R7.0.4
Philips XPER FD10C R7.0.4 Reconditioned 2005 System- Upgraded to R7 in Oct 2010 The Allura Xper FD10 (Ceiling) single-plane cardiovascular system is comprised of a ceiling mounted C-arm stand and digital
More informationJoint ICTP/IAEA Advanced School on Dosimetry in Diagnostic Radiology and its Clinical Implementation May 2009
2033-6 Joint ICTP/IAEA Advanced School on Dosimetry in Diagnostic Radiology and its Clinical Implementation 11-15 May 2009 Dosimetry for Fluoroscopy Basics Renato Padovani EFOMP Joint ICTP-IAEA Advanced
More informationCHAPTER 6 QC Test For Fluoroscopic Equipment. Prepared by:- Kamarul Amin bin Abu Bakar School of Medical Imaging KLMUC
CHAPTER 6 QC Test For Fluoroscopic Equipment Prepared by:- Kamarul Amin bin Abdullah @ Abu Bakar School of Medical Imaging KLMUC Lesson Outcomes Describe the objectives of each QC test done. Identify QC
More informationINTRODUCTION TO FLEXIBLE BRONCHOSCOPY. Fluoroscopy Synopsis HENRI G COLT MD SECOND EDITION THE BRONCHOSCOPY EDUCATION PROJECT SERIES
SECOND EDITION INTRODUCTION TO FLEXIBLE BRONCHOSCOPY Fluoroscopy Synopsis HENRI G COLT MD With contributions from Dr. S. Murgu THE BRONCHOSCOPY EDUCATION PROJECT SERIES FLUOROSCOPY SYNOPSIS The purpose
More informationSome operation methods show in the catalog reguire optional eguipment
Some operation methods show in the catalog reguire optional eguipment I'm interested in real-time imaging with a larger field of view. I wish to acquire high-definition images while reducing exposure dose.
More informationDistributed by. Ecotron Anyview Series. The Intelligent C-Arm System
Distributed by Ecotron Anyview Series The Intelligent C-Arm System The Ecotron Anyview Series is a new standard for C-arm imaging Excellent radiographic imaging at an economical price Advanced X-ray Generator
More informationEnhanced Functionality of High-Speed Image Processing Engine SUREengine PRO. Sharpness (spatial resolution) Graininess (noise intensity)
Vascular Enhanced Functionality of High-Speed Image Processing Engine SUREengine PRO Medical Systems Division, Shimadzu Corporation Yoshiaki Miura 1. Introduction In recent years, digital cardiovascular
More informationTruly flexible to meet your clinical needs
Truly flexible to meet your clinical needs 2 Adapting to meet your needs Flexible Fast and responsive Excellent image quality Designed with ergonomic efficiency Equipped with dose management tools 3 Three
More informationVisualization of sources of scattered radiation from x-ray equipment used for interventional radiology
Visualization of sources of scattered radiation from x-ray equipment used for interventional radiology Poster No.: C-1190 Congress: ECR 2011 Type: Scientific Exhibit Authors: K. Chida, T. Takahashi, D.
More informationSarah Hughes, MS, DABR Radiation Safety Officer
Sarah Hughes, MS, DABR Radiation Safety Officer 502-852-6146 sarah.hughes@louisville.edu Mo my back is burnin!!! I got it MAG the cine! Sumthin s not right. Where s his heart? Fluoroscopy http://dccwww.bumc.bu.edu/fluoroscopy/def
More informationNuclear Associates , &
Nuclear Associates 76-810, 76-814 76-815 & 76-818 Bar Phantoms and Test Patterns Operators Manual March 2005 Manual No. 76-810-1 Rev. 2 2004, 2005 Fluke Corporation, All rights reserved. Printed in U.S.A.
More informationMXHF-1500RF is controlled by Digital key panel console that displays KV, ma and mas with APR menu programmed.
R/F TV X-RAY SYSTEM DIAGNOSTIC RADIOGRAPHIC FLUOROSCOPIC TV SYSTEM MXHF-1500RF SYSTEM OUTLINE Product Data No. 041021-01 MXHF-1500RF is controlled by Digital key panel console that displays KV, ma and
More informationMultiple Choice Identify the letter of the choice that best completes the statement or answers the question.
RA110 test 3 Multiple Choice Identify the letter of the choice that best completes the statement or answers the question. 1. An object 35 cm in width is radiographed at 100 cm SID and at a 50 cm SOD. What
More informationOverview of Safety Code 35
Common Quality Control Procedures for All s Quality Control Procedures Film All s Daily Quality Control Tests Equipment Warm-up (D1) According to manufacturers instructions Can include auto calibration(d1)
More informationI. PERFORMANCE OF X-RAY PRODUCTION COMPONENTS FLUOROSCOPIC ACCEPTANCE TESTING: TEST PROCEDURES & PERFORMANCE CRITERIA
FLUOROSCOPIC ACCEPTANCE TESTING: TEST PROCEDURES & PERFORMANCE CRITERIA EDWARD L. NICKOLOFF DEPARTMENT OF RADIOLOGY COLUMBIA UNIVERSITY NEW YORK, NY ACCEPTANCE TESTING GOALS PRIOR TO 1st CLINICAL USAGE
More informationX-RAYS - NO UNAUTHORISED ENTRY
Licencing of premises Premises Refer Guidelines A radiation warning sign and warning notice, X-RAYS - NO UNAUTHORISED ENTRY must be displayed at all entrances leading to the rooms where x-ray units are
More informationC506-E064. Full digital system. Printed in Japan A-NS
C506-E064 Full digital system Printed in Japan 6295-08807-30A-NS Full digital system Highest Image Quality in Its Class Comprehensive Full-Digital System FLEXAVISION is a full-digital R/F system equipped
More informationMammography is a radiographic procedure specially designed for detecting breast pathology Approximately 1 woman in 8 will develop breast cancer over
Mammography is a radiographic procedure specially designed for detecting breast pathology Approximately 1 woman in 8 will develop breast cancer over a lifetime Breast cancer screening programs rely on
More informationBeam-Restricting Devices
Beam-Restricting Devices Three factors contribute to an increase in scatter radiation: Increased kvp Increased Field Size Increased Patient or Body Part Size. X-ray Interactions a some interact with the
More informationsiemens.com/luminos-fusion Luminos Fusion The 2-in-1 system that fits your needs and fits your budget
siemens.com/luminos-fusion Luminos Fusion The 2-in-1 system that fits your needs and fits your budget Luminos Fusion The 2-in-1 system that fits your needs and fits your budget Luminos Fusion provides
More informationSPECIFICATION. Kilovoltage X-ray calibration system for protection and diagnostic level dosimetry. Prepared by
SPECIFICATION Kilovoltage X-ray Prepared by Igor Gomola, Technical Officer, Project ECU6023, Date 2015-Oct-06 Revision Date Status Comments 0.1 2015-Oct-06 Draft Igor Gomola Page 1 of 12 1. Scope This
More informationORAMED S MEASUREMENT AND SIMULATION CAMPAIGN FOR EXREMITY AND EYE LENS DOSES OF MEDICAL STAFF INVOLVED IN INTERVENTIONAL RADIOLOGY AND CARDIOLOGY
ORAMED S MEASUREMENT AND SIMULATION CAMPAIGN FOR EXREMITY AND EYE LENS DOSES OF MEDICAL STAFF INVOLVED IN INTERVENTIONAL RADIOLOGY AND CARDIOLOGY Carinou E., Brodecki M.,Domienik J., Donadille L., Ferrari
More informationAIR KERMA RATES MEASUREMENT IN AN INTERVENTIONAL CARDIOLOGY SUITE
AIR KRMA RATS MASURMNT IN AN INTRVNTIONAL ARIOLOGY SUIT anevaro, L.V. 1 ; Gamarra Sanchez, M..; Pereira, L.S.; Maurício,.L.P. Instituto de Radioproteção e osimetria. omissão Nacional de nergia Nuclear.
More informationTeaching Digital Radiography and Fluoroscopic Radiation Protection
Teaching Digital Radiography and Fluoroscopic Radiation Protection WCEC 20 th Student Educator Radiographer Conference Dennis Bowman, RT(R), CRT (R)(F) Community Hospital of the Monterey Peninsula (CHOMP)
More informationOverview. Professor Roentgen was a Physicist!!! The Physics of Radiation Oncology X-ray Imaging
The Physics of Radiation Oncology X-ray Imaging Charles E. Willis, Ph.D. DABR Associate Professor Department of Imaging Physics The University of Texas M.D. Anderson Cancer Center Houston, Texas Overview
More informationCollimation Assessment Using GAFCHROMIC XR-M2
Collimation Assessment Using GAFCHROMIC XR-M2 I. Introduction A method of collimation assessment for GE Senographe full-field digital mammography (FFDM) systems is described that uses a self-developing
More informationDiagnostic X-Ray Shielding
Diagnostic X-Ray Shielding Multi-Slice CT Scanners Using NCRP 147 Methodology Melissa C. Martin, M.S., FAAPM, FACR Therapy Physics Inc., Bellflower, CA AAPM Annual Meeting, Orlando, FL FL Refresher Course
More informationX-RAY IMAGING EE 472 F2017. Prof. Yasser Mostafa Kadah
X-RAY IMAGING EE 472 F2017 Prof. Yasser Mostafa Kadah www.k-space.org Recommended Textbook Stewart C. Bushong, Radiologic Science for Technologists: Physics, Biology, and Protection, 10 th ed., Mosby,
More informationMulti-Access Biplane Lab
Multi-Access Biplane Lab Advanced technolo gies deliver optimized biplane imaging Designed in concert with leading physicians, the Infinix VF-i/BP provides advanced, versatile patient access to meet the
More informationX-ray Imaging. PHYS Lecture. Carlos Vinhais. Departamento de Física Instituto Superior de Engenharia do Porto
X-ray Imaging PHYS Lecture Carlos Vinhais Departamento de Física Instituto Superior de Engenharia do Porto cav@isep.ipp.pt Overview Projection Radiography Anode Angle Focal Spot Magnification Blurring
More informationC-ARM FLUOROSCOPIC AND SPOT-FILM SYSTEMS
PART X C-ARM FLUOROSCOPIC AND SPOT-FILM SYSTEMS FORM FD 3260 REPRINTED APRIL 2000 ROUTINE COMPLIANCE TESTING C-ARM FLUOROSCOPES (Test Procedure CFA - Use Form FDA 3260) 1.0 GENERAL GUIDANCE 1.1 This procedure
More informationCh. 223 VETERINARY MEDICINE CHAPTER 223. VETERINARY MEDICINE GENERAL PROVISIONS X-RAYS RADIOACTIVE MATERIAL. Authority
Ch. 223 VETERINARY MEDICINE 25 223.1 CHAPTER 223. VETERINARY MEDICINE Sec. 223.1. Purpose and scope. 223.2. [Reserved]. 223.2a. Definitions. 223.3 223.6. [Reserved]. 223.7. Structural shielding. 223.8.
More information10/3/2012. Study Harder
This presentation is a professional collaboration of development time prepared by: Rex Christensen Terri Jurkiewicz and Diane Kawamura Study Harder CR detection is inefficient, inferior to film screen
More informationDigital Imaging started in the 1972 with Digital subtraction angiography Clinical digital imaging was employed from the 1980 ~ 37 years ago Amount of
Digital Imaging started in the 1972 with Digital subtraction angiography Clinical digital imaging was employed from the 1980 ~ 37 years ago Amount of radiation to the population due to Medical Imaging
More informationRADIATION SAFETY REQUIREMENTS FOR ANALYTICAL X-RAY EQUIPMENT
420-3-26-.11 RADIATION SAFETY REQUIREMENTS FOR ANALYTICAL X-RAY EQUIPMENT (1) Purpose and Scope. This rule 420-3-26-.11 provides special requirements for analytical x- ray equipment; provided, however,
More informationGet more from your images with Symphony Image Processing
DIRECT RADIOGRAPHY The user-friendly DelWorks image acquisition and processing software possesses a wide range of tools for a variety of image manipulations. Its user interface simplifies every step of
More informationRADspeed Pro DIGITAL RADIOGRAPHIC SYSTEM. IBD-RADProAeroDR
RADspeed Pro DIGITAL RADIOGRAPHIC SYSTEM IBD-RADProAeroDR Sophisticated Functions Make System Operation Even Easier Revolutionary Auto-Positioning Allows the Operator to Focus On Patient Care The auto-positioning
More information10/26/2015. Study Harder
This presentation is a professional collaboration of development time prepared by: Rex Christensen Terri Jurkiewicz and Diane Kawamura Study Harder CR detection is inefficient, inferior to film screen
More informationFluoroscopy - Chapter 9
Fluoroscopy - Chapter 9 Kalpana Kanal, Ph.D., DABR Lecturer, Diagnostic Physics Dept. of Radiology UW Medicine a copy of this lecture may be found at: http://courses.washington.edu/radxphys/physicscourse04-05.html
More informationHISTORY. CT Physics with an Emphasis on Application in Thoracic and Cardiac Imaging SUNDAY. Shawn D. Teague, MD
CT Physics with an Emphasis on Application in Thoracic and Cardiac Imaging Shawn D. Teague, MD DISCLOSURES 3DR- advisory committee CT PHYSICS WITH AN EMPHASIS ON APPLICATION IN THORACIC AND CARDIAC IMAGING
More informationx_ray solutions We understand that customers don t need just products, they want solutions
x_ray solutions We understand that customers don t need just products, they want solutions index 1974-2005 2006-2007 - 2008 ITALRAY Srl was founded in 1974 as the production branch of Marzocchi L&C SpA,
More informationNuclear Associates
Nuclear Associates 07-706 Patient Phantom/Penetrometer System Users Manual March 2005 Manual No. 07-706-1 Rev. 2 2004, 2005 Fluke Corporation, All rights reserved. Printed in U.S.A. All product names are
More informationCOMPUTED RADIOGRAPHY CHAPTER 4 EFFECTIVE USE OF CR
This presentation is a professional collaboration of development time prepared by: Rex Christensen Terri Jurkiewicz and Diane Kawamura New Technology https://www.youtube.com/watch?v=ptkzznazb 7U COMPUTED
More informationMinnesota Rules, Chapter 4732 X-ray Revision
Minnesota Rules, Chapter 4732 X-ray Revision PROPOSED DRAFT GAUGING X-RAY SYSTEMS, 1.0 4732.#### GAUGING X-RAY SYSTEMS. Subpart 1. Applicability. A registrant s gauging x-ray system must comply with the
More informationNuclear Associates
Nuclear Associates 07-647 R/F QC Phantom Operators Manual March 2005 Manual No. 07-647-1 Rev. 2 2004, 2005 Fluke Corporation, All rights reserved. All product names are trademarks of their respective companies
More informationFMT18 FLOOR MOUNTED SYSTEM
mas Time AEC 320 kvp 64 mas 320 ma 320 ma 320 DEN 0.0 mm Cu 17 in X 17 in 72.0 in FMT18 FLOOR MOUNTED SYSTEM with Synchronized Tracking System Overview Clinical Efficiency The FMT18 System was designed
More informationRAD 150 RADIOLOGIC EXPOSURE TECHNIQUE II
RAD 150 RADIOLOGIC EXPOSURE TECHNIQUE II APPROVED 12/O2/2011 EFFECTIVE SPRING 2013-14 Prefix & Number RAD 150 Course Title: Radiologic Exposure Technique II & Lab Purpose of this submission: New Change/Updated
More informationOTC18 OVERHEAD TUBE CRANE SYSTEM
OTC18 OVERHEAD TUBE CRANE SYSTEM System Overview Clinical Performance Versatile and intuitive, the OTC18M System delivers enhanced patient comfort and optimized workflow. Precisely designed to withstand
More informationGet more from your images with Symphony Image Processing
DIRECT RADIOGRAPHY The user-friendly DelWorks image acquisition and processing software provides a wide range of tools for a variety of image enhancements. Its user interface simplifies every step of the
More informationIntroduction. Chapter 16 Diagnostic Radiology. Primary radiological image. Primary radiological image
Introduction Chapter 16 Diagnostic Radiology Radiation Dosimetry I Text: H.E Johns and J.R. Cunningham, The physics of radiology, 4 th ed. http://www.utoledo.edu/med/depts/radther In diagnostic radiology
More informationR&F X-ray systsem. Savings With Every Exposure
R&F X-ray systsem Savings With Every Exposure Savings with every exposure Versatility meets value Dependable performance User-friendly interface Expandable imaging capabilities Excellent image quality
More informationNuclear Associates
Nuclear Associates 76-700 Digital Subtraction Angiography Phantom Users Manual March 2005 Manual No. 76-700-1 Rev. 2 2004, 2005 Fluke Corporation, All rights reserved. Printed in U.S.A. All product names
More informationVeterinary Science Preparatory Training for the Veterinary Assistant. Floron C. Faries, Jr., DVM, MS
Veterinary Science Preparatory Training for the Veterinary Assistant Floron C. Faries, Jr., DVM, MS Radiology Floron C. Faries, Jr., DVM, MS Objectives Determine the appropriate machine settings for making
More informationClinical Experiences with a Patient Skin Dose Monitoring and Tracking Program
Clinical Experiences with a Patient Skin Dose Monitoring and Tracking Program Allen R. Goode, MS, DABR Chief Diagnostic Medical Physicist Department of Radiology & Medical Imaging University of Virginia
More informationNuclear Associates
Nuclear Associates 07-649 CDRH Fluoroscopic Phantom Users Manual March 2005 Manual No. 07-649-1 Rev. 2 2004, 2005 Fluke Corporation, All rights reserved. Printed in U.S.A. All product names are trademarks
More informationARCO Rk.5 Digital Mobile C-Arm
Product Data ARCO Rk.5 Digital Mobile C-Arm Product Data 1 Easy to move INTRODUCTION Designed with the latest technology throughout, the ARCO Rk.5 set new standards for the excellence image quality ease
More informationApplication Note. ipix A Gamma imager to support various applications. Introduction. An easy to carry and deploy instrument
Application Note ipix A Gamma imager to support various applications Introduction ipix is a unique gamma imager that quickly locates low level radioactive sources from a distance and estimates the dose
More informationPLD5600A High Frequency Digital Gastrointestinal &DR System(630mA)
PLD5600A High Frequency Digital Gastrointestinal &DR System(630mA) Application: Full support perspective, gastrointestinal spot film, GI (barium meal, barium enema), orthopedic photography, pediatrics
More informationuniversal Digital Radiography (DR) System
Vision Air universal Digital Radiography (DR) System Technical Specification Vision Air is a state-of-the-art, universal, overhead digital radiography system capable of virtually all radiography examinations
More informationX-RAY SAFETY REFRESHER EXAM
X-RAY SAFETY REFRESHER EXAM DIRECTIONS: Please print this quiz and fill in the information requested. Mark the correct answer to each question. When completed either scan and email the quiz to the Radiation
More informationKey words: fluoroscopy, dose-area-product, kerma-area-product, calibration of KAP meters, patient exposure
Accuracy and calibration of integrated radiation output indicators in diagnostic radiology: A report of the AAPM Imaging Physics Committee Task Group 190 Pei-Jan P. Lin a) Virginia Commonwealth University
More informationTABLE OF CONTENTS. References
ANALYTICAL X-RAY EQUIPMENT USE POLICIES & PROCEDURES Page 1 of 9 Revised: 11/24/2003 TABLE OF CONTENTS 1.0 General 2.0 Purpose 3.0 Scope and Authority 4.0 Equipment Requirements 4.0.1 Safety device 4.0.2
More information> Microwave Ovens and their Hazards
1 of 6 16/02/2012 7:48 PM Home > OSH Answers > Physical Agents > Microwave Ovens and their Hazards Ask a Question Feedback Printer-friendly Why do people worry about microwave radiation? How do microwave
More information3/31/2011. Objectives. Emory University. Historical Development. Historical Development. Historical Development
Teaching Radiographic Technique in a Digital Imaging Paradigm Objectives 1. Discuss the historical development of digital imaging. Dawn Couch Moore, M.M.Sc., RT(R) Assistant Professor and Director Emory
More informationAutomated dose control in multi-slice CT. Nicholas Keat Formerly ImPACT, St George's Hospital, London
Automated dose control in multi-slice CT Nicholas Keat Formerly ImPACT, St George's Hospital, London Introduction to presentation CT contributes ~50+ % of all medical radiation dose Ideally all patients
More information2D, 3D CT Intervention, and CT Fluoroscopy
2D, 3D CT Intervention, and CT Fluoroscopy SOMATOM Definition, Definition AS, Definition Flash Answers for life. Siemens CT Vision Siemens CT Vision The justification for the existence of the entire medical
More informationMAN Revision 002. InSight Mini C-arm Imaging System Technical Reference Manual
MAN-00668 Revision 002 InSight Mini C-arm Imaging System Technical Reference Manual April 2007 The information contained in this Manual is confidential and proprietary to Hologic, Inc. This information
More informationDiffraction-enhanced X-ray Imaging (DEXI) Medical Solutions. More information using less radiation
Diffraction-enhanced X-ray Imaging (DEXI) Medical Solutions More information using less radiation Medical Small Animal Security NDE/NDT Diffraction-Enhanced X-ray Imaging Medical Solutions Safe non-invasive
More informationEssentials of Digital Imaging
Essentials of Digital Imaging Module 6 Transcript 2016 ASRT. All rights reserved. Essentials of Digital Imaging Module 6 Dose Reduction and Patient Safety 1. ASRT Animation 2. Welcome Welcome to Essentials
More informationMULTIX PRO/TOP VERTIX PRO/TOP VERTIX Solitaire X-ray systems for radiographic rooms that make life easier
MULTIX PRO/TOP VERTIX PRO/TOP VERTIX Solitaire X-ray systems for radiographic rooms that make life easier Over 1,000 systems sold! MULTIX PRO/TOP VERTIX PRO/TOP VERTIX Solitaire Faster and safer diagnosis
More informationUpdate on Fluoroscopy Physics AAPM MO-A-210A-1 Stephen Balter, Ph.D.
Update on Fluoroscopy Physics Stephen Balter, PhD Columbia University Draft for MO-A-210A-1 2009 AAPM Educational objectives Understand dosimetric concepts relating to interventional fluoroscopy Characterize
More informationVisibility of Detail
Visibility of Detail Radiographic Quality Quality radiographic images represents the, and information is for diagnosis. The of the anatomic structures and the accuracy of their ( ) determine the overall
More informationINNOVATION BY DESIGN. Toshiba A History of Leadership REMOTE CONTROL R/F SYSTEM
INNOVATION BY DESIGN For over 130 years, Toshiba has led the world in developing technology to improve the quality of life. This Made for Life TM commitment is reflected in our family of leading-edge imaging
More informationSYLLABUS. 1. Identification of Subject:
SYLLABUS Date/ Revision : 30 January 2017/1 Faculty : Life Sciences Approval : Dean, Faculty of Life Sciences SUBJECT : Biophysics 1. Identification of Subject: Name of Subject : Biophysics Code of Subject
More informationLuminos drf Max. Taking 2-in-1 to the MAX in radiography and fluoroscopy. siemens.com/luminos-drf-max
Luminos drf Max Taking 2-in-1 to the MAX in radiography and fluoroscopy siemens.com/luminos-drf-max 2 It s more. It s MAX. MAX Multiple Advances in X-ray It s more than just single features or functions.
More informationDo you have any other questions? Please call us at (Toll Free) or , or
INSTRUCTIONS Read the appropriate course/ textbook. This is an open book test. A score of 75% or higher is needed to receive CE credit. You will have a maximum of three attempts to pass this course. Please
More informationUnfors EDD-30 Radiation Protection in Fluoroscopy
Unfors EDD-30 Radiation Protection in Fluoroscopy Immediate Warning Decrease Your Dose Interventional radiology procedures are considered to be essential to medical diagnosis and treatment. It is recognized,
More information4. Contrast is the. There must The function of contrast is to:. The types of contrast are.
RADIOGRAPHIC VISIBILITY OF DETAIL STUDY QUESTIONS 1. What is visibility of detail? It is controlled by properties. What are the two factors that affect it? 2. What is sharpness of detail? It is controlled
More informationY11-DR Digital Radiography (DR) Image Quality
Y11-DR Digital Radiography (DR) Image Quality Image quality is stressed for all systems in Safety Code 35. In the relevant sections Health Canada s advice is the manufacturer s recommended test procedures
More informationLuminos RF Classic. Where value meets performance.
Luminos RF Classic Where value meets performance www.siemens.com/healthcare What s good value in fluoroscopy? That s easy. Luminos RF Classic. 2 Whether for its handling convenience, outstanding image
More informationSECTION I - CHAPTER 2 DIGITAL IMAGING PROCESSING CONCEPTS
RADT 3463 - COMPUTERIZED IMAGING Section I: Chapter 2 RADT 3463 Computerized Imaging 1 SECTION I - CHAPTER 2 DIGITAL IMAGING PROCESSING CONCEPTS RADT 3463 COMPUTERIZED IMAGING Section I: Chapter 2 RADT
More informationSafelight Fog does what to contrast and density on film?
Terri Jurkiewicz Safelight Fog does what to contrast and density on film? ANSWER INCREASES DENSITY DECREASES CONTRAST Explain how you determine if the focal spot size is within appropriate limits.
More informationX-rays. X-rays are produced when electrons are accelerated and collide with a target. X-rays are sometimes characterized by the generating voltage
X-rays Ouch! 1 X-rays X-rays are produced when electrons are accelerated and collide with a target Bremsstrahlung x-rays Characteristic x-rays X-rays are sometimes characterized by the generating voltage
More informationProduct data Remote Controlled Table
Product data Remote Controlled Table Product data Remote Controlled Table 2 BRT-20 Remote controlled table has been designed as basic equipment, compact and extremely simplified. MAIN APPLICATION Gastroenterology
More informationSONIALVISION G4 Multi-purpose Digital R/F System C506-E075
SONIALVISION G4 Multi-purpose Digital R/F System C506-E075 Selecting the best for every examination environment BEST in CLASS Multi-purpose Digital R/F System 2 With the Sonialvision G4, Shimadzu offers
More informationSONIALVISION G4 Multi-purpose Digital R/F System C506-E075
SONIALVISION G4 Multi-purpose Digital R/F System C506-E075 Selecting the best for every examination environment BEST in CLASS Multi-purpose Digital R/F System With the Sonialvision G4, Shimadzu offers
More informationInitials. Policy #:
APPROVED BY: Director of Radiology Page 1 of 6 Siemens AXIOM Luminos Agile Ysio Clinical Checklist ROOM 2 Technologist: Training Dates: Table Controls Park Unpark DIT Patient Transfer Vertical Patient
More informationCalibration of KAP meters
Calibration of KAP meters Alexandr Malusek! Division of Radiological Sciences Department of Medical and Health Sciences Linköping University! 2014-04-15 1 Outline 1. KAP meter construction 2. Air kerma-area
More informationSONIALVISION G4 Multi-purpose Digital R/F System
C506-E075A SONIALVISION G4 Multi-purpose Digital R/F System Founded in 1875, Shimadzu Corporation, a leader in the development of advanced technologies, has a distinguished history of innovation built
More informationMaxRay Handheld X-ray Systems Operator Training Exam
MaxRay Handheld X-ray Systems Operator Training Exam Employee: Instructor: ate: Score: Instructions Read each question carefully and choose the best answer. 1) LR is 2) 3) 4) a. a safety principle meant
More informationLudlum Medical Physics
Ludlum Medical Physics Medical Imaging Radiology QA Test Tools NEW LUDLUM PRODUCT LINE Medical Physics Products Medical Physics Products What are they? Products used to measure radiation output and to
More informationYSF - 300/DAR i
C506-E067 Integrated Digital R/F System YSF - 300/DAR - 8000i photo shown with optional I.I. cover A Fully Integrated Digital R/F System Expanding the Clinical Boundaries. With more than 130 years of dedication
More informationMinnesota Rules, Chapter 4732 X-ray Revision
Minnesota Rules, Chapter 4732 X-ray Revision PROPOSED DRAFT BOMB DETECTION X-RAY SYSTEMS, 1.0 4732.#### BOMB DETECTION X-RAY SYSTEMS. Subpart 1. Applicability. A registrant s bomb detection x-ray system
More informationAcquisition, Processing and Display
Acquisition, Processing and Display Terri L. Fauber, R.T. (R)(M) Department of Radiation Sciences School of Allied Health Professions Virginia Commonwealth University Topics Image Characteristics Image
More informationChina Resources Wandong Medical Equipment Co., Ltd. High Frequency 50kW, 150kV Radiography System - HF50-R
China Resources Wandong Medical Equipment Co., Ltd. High Frequency 50kW, 150kV Radiography System - HF50-R Building 3, No.9, Jiuxianqiaodong Road, Chaoyang District, Beijing 100015, P.R. China E-mail:
More informationMaking the difference with Live Image Guidance
Surgery BV Endura Making the difference with Live Image Guidance BV Endura mobile C-arm system specifications K e yb e n e fi t s Versatile system with choice between 9" or 12" image intensifier for a
More informationPerformance and care. all in one
Performance and care all in one INNOVATION IS WHAT DRIVES US THINKING ABOUT THE FUTURE Preventive diagnostics remains an essential weapon in defeating breast cancer. Metaltronica s forward-thinking design
More informationIntraoral X-Ray For Film and Digital Systems
Intraoral X-Ray For Film and Digital Systems ImageWorks Generations of Imaging With the full line of Endos intraoral X-ray units, everything has been designed to maximize operating efficiency while allowing
More informationRadiology. Radiograph: Is the image of an object made with use of X- ray instead of light.
Radiology د. اريج Lec. 3 X Ray Films Radiograph: Is the image of an object made with use of X- ray instead of light. Dental x- ray film: Is a recording media on which image of the object was made by exposing
More information(a) This subchapter applies to installations using analytical x-ray equipment and establishes requirements for their use.
SUBCHAPTER 21. ANALYTICAL X-RAY INSTALLATIONS 7:28-21.1 Scope (a) This subchapter applies to installations using analytical x-ray equipment and establishes requirements for their use. (b) The provisions
More information