SONOGRAPHIC PHYSICS, INSTRUMENTATION & DOPPLER REVIEW Part 3
|
|
- Ginger Mitchell
- 5 years ago
- Views:
Transcription
1 SONOGRAPHIC PHYSICS, INSTRUMENTATION & DOPPLER REVIEW 2012 Part 3 1
2 Doppler Imaging 2
3 DOPPLER TRANSDUCER SAME FREQUENCY During Doppler operation, the reflected sound has the same frequency as the transmitted sound if the blood is stationary. 3
4 DOPPLER TRANSDUCER LOWER FREQUENCY During Doppler operation, the reflected sound has a lower frequency if the blood is moving away from the sound source. 4
5 DOPPLER TRANSDUCER HIGHER FREQUENCY During Doppler operation, the reflected sound has a higher frequency if the blood is moving toward the sound source. 5
6 DOPPLER SHIFT f 6
7 DOPPLER SHIFT FORMULA An increase in blood velocity produces an increase in the Doppler shift. An increase in the transmitted frequency produces an increase in the Doppler shift. A Doppler angle of 0º produces the maximum possible Doppler shift. A Doppler shift is not produced when the Doppler angle is 90º. 7
8 BLOOD VELOCITY FORMULA A Doppler system is capable of measuring only the Doppler shift. It calculates the blood velocity. An increase in the Doppler shift produces an increase in the calculated blood velocity. 8
9 DOPPLER RELATIONSHIPS TRANSMITTED FREQUENCY f o DOPPLER ANGLE q BLOOD VELOCITY V DOPPLER SHIFT f Increase Increase Decrease Decrease Increase Decrease Decrease Increase Increase Increase Decrease Decrease 9
10 DOPPLER CALCULATIONS Doppler shifts ( f) for V = 100 cm per second c = 1550 meters per second q cos q f o = 2.5 MHz f o = 5.0 MHz Hz 6452 Hz Hz 5588 Hz Hz 4562 Hz Hz 3226 Hz Hz 1670 Hz Hz 0 Hz 10
11 DOPPLER SHIFT EXAMPLE TRANSMITTED FREQUENCY RECEIVED FREQUENCY DOPPLER SHIFT f DIRECTION OF FLOW TO SOUND 5 MHz MHz 5 khz Away 5 MHz MHz 5 khz Toward 11
12 SPECTRAL DOPPLER FFT DISPLAY: POSITIVE DOPPLER SHIFT WITHOUT SPECTRAL BROADENING FREQUENCY SCALES FFT DISPLAY: POSITIVE DOPPLER SHIFT WITH SPECTRAL BROADENING 12
13 CW SPECTRAL DOPPLER NON-IMAGING CW B-MODE IMAGING AND CW 13
14 CW SPECTRAL DOPPLER NON-IMAGING CARDIAC CW DOPPLER TRANSDUCER 14
15 CW SPECTRAL DOPPLER CW DOPPLER DETECTING SHIFTS FROM MORE THAN ONE VESSEL 15
16 CW SPECTRAL DOPPLER B-MODE AND CW DOPPLER WITH SPECTRUM ANALYZER DISPLAY 16
17 PW SPECTRAL DOPPLER PW TRANSMITTING PW RECEIVING 17
18 PW SPECTRAL DOPPLER NON-IMAGING PW B-MODE IMAGING AND PW 18
19 PW SPECTRAL DOPPLER 19
20 PW SPECTRAL DOPPLER NORMAL SAMPLE VOLUME WITH NO SPECTRAL BROADENING LARGER THAN NORMAL SAMPLE VOLUME WITH SPECTRAL BROADENING 20
21 PW SPECTRAL DOPPLER PW TRANSDUCERS USED FOR TRANSCRANIAL DOPPLER 21
22 PW - ALIASING WRAP-AROUND 22
23 PW - ALIASING POSITIVE DOPPLER SHIFT WITH THE NYQUIST LIMIT (N.L) EXCEEDED AS A RESULT OF HIGH VELOCITY FLOW 23
24 PW - ALIASING ALIASING: NYQUIST LIMIT EXCEEDED SAME DOPPLER SHIFT BUT ALIASING ELIMINATED SCALE ADJUSTED TO INCREASE THE PULSE DOPPLER PRF AND RAISE THE NYQUIST LIMIT 24
25 PW - ALIASING ALIASING: NYQUIST LIMIT EXCEEDED SAME DOPPLER SHIFT BUT ALIASING ELIMINATED BASE LINE LOWERED TO INCREASE THE PULSE DOPPLER PRF AND RAISE THE NYQUIST LIMIT 25
26 PW - ALIASING ALIASING: NYQUIST LIMIT EXCEEDED ALIASING ELIMINATED DOPPLER ANGLE INCREASED SCALE, BASELINE, AND PRF UNCHANGED 26
27 PW - ALIASING ALIASING: NYQUIST LIMIT EXCEEDED ALIASING ELIMINATED TRANSDUCER FREQUENCY DECREASED SCALE, BASELINE, AND PRF UNCHANGED 27
28 PW - ALIASING NYQUIST LIMIT EXCEEDED 28
29 NYQUIST LIMIT NYQUIST LIMITS (PRF 2) PRF N.L. 1 khz (1000 Hz) 500 Hz 2 khz (2000 Hz) 1000 Hz 3 khz (3000 Hz) 1500 Hz 4 khz (4000 Hz) 2000 Hz 5 khz (5000 Hz) 2500 Hz 6 khz (6000 Hz) 3000 Hz 29
30 CW NO ALIASING 30
31 ANGLE-CORRECT PW - VELOCITY CORRECT: PROPER ANGLE-CORRECT VELOCITY SCALES PW - VELOCITY INCORRECT: IMPROPER ANGLE-CORRECT 31
32 WALL FILTERS WALL FILTER SETTING NORMAL WALL FILTER SETTING TOO HIGH 32
33 DOPPLER GAIN DOPPLER GAIN SETTING NORMAL DOPPLER GAIN SETTING TOO HIGH 33
34 Color-flow Imaging 34
35 COLOR-FLOW IMAGING 35
36 COLOR-FLOW IMAGING STANDARD COLOR MAP 36
37 COLOR-FLOW IMAGING ENHANCED COLOR MAP 37
38 COLOR-FLOW IMAGING STANDARD COLOR MAP 38
39 COLOR-FLOW IMAGING COLOR VARIANCE MAP 39
40 COLOR-FLOW IMAGING CAROTID 40
41 COLOR-FLOW IMAGING STANDARD COLOR MAP COLOR DOPPLER SAMPLE ANGLES 2-D, SPECTRAL DOPPLER, & COLOR-FLOW DOPPLER ECHOCARDIOGRAPHIC STUDY (Triplex) 41
42 COLOR-FLOW IMAGING COLOR-FLOW DOPPLER 42
43 COLOR-FLOW & POWER DOPPLER IMAGING COLOR-FLOW DOPPLER POWER DOPPLER 43
44 POWER DOPPLER & SPECTRAL DOPPLER 44
Lesson 12: Doppler Principles. This lesson contains 50 slides plus 26 multiple-choice questions.
Lesson 12: Doppler Principles This lesson contains 50 slides plus 26 multiple-choice questions. Accompanying text for the slides in this lesson can be found on pages 59 through 80 in the textbook: DOPPLER
More informationDoppler Ultrasound. Amanda Watson.
Doppler Ultrasound Amanda Watson amanda.watson1@nhs.net Before we start Why does blood appear black on a B-mode image? B-mode echoes vs. Doppler echoes In B-Mode we are concerned with the position and
More informationIntroduction to Ultrasound Physics
Introduction to Ultrasound Physics Vassilis Sboros Medical Physics and Cardiovascular Sciences University of Edinburgh Transverse waves Water remains in position Disturbance traverse producing more wave
More information4 Working With Scan Modes
4 Working With Scan Modes Scan Modes Overview All of the information in this chapter pertains to live imaging. Many of the controls and functions change when you freeze the scan. For information on using
More informationOptimisation of Image Acquisition Bordeaux 16th November J.S. McGhie W.B. Vletter R. Frowijn No disclosures
Optimisation of Image Acquisition Bordeaux 16th November 2016 J.S. McGhie W.B. Vletter R. Frowijn No disclosures Image optimisation: The Echo machine It looks difficult to drive an echo machine!! Some
More informationImage Optimization: The Sonographer s Responsibility. Prepared by Cathy Daniels, EdD, RTR, RDMS, RDCS, RVT
Image Optimization: The Sonographer s Responsibility Prepared by Cathy Daniels, EdD, RTR, RDMS, RDCS, RVT Image Optimization: The Sonographer s Responsibility Cathy Daniels, EdD, RTR, RDMS, RDCS, RVT Disclosure
More informationS S S2 Operation Manual
PREPARATION 1. How to create and input patient data? In the MAIN INTERFACE, press the key, to enter into the patient exam list interface. Then, click New patient item to create new patient files. Patient
More informationEMBEDDED DOPPLER ULTRASOUND SIGNAL PROCESSING USING FIELD PROGRAMMABLE GATE ARRAYS
EMBEDDED DOPPLER ULTRASOUND SIGNAL PROCESSING USING FIELD PROGRAMMABLE GATE ARRAYS Diaa ElRahman Mahmoud, Abou-Bakr M. Youssef and Yasser M. Kadah Biomedical Engineering Department, Cairo University, Giza,
More informationPhysics of Ultrasound Ultrasound Imaging and Artifacts รศ.นพ.เดโช จ กราพาน ชก ล สาขาหท ยว ทยา, ภาคว ชาอาย รศาสตร คณะแพทยศาสตร ศ ร ราชพยาบาล
Physics of Ultrasound Ultrasound Imaging and Artifacts รศ.นพ.เดโช จ กราพาน ชก ล สาขาหท ยว ทยา, ภาคว ชาอาย รศาสตร คณะแพทยศาสตร ศ ร ราชพยาบาล Diagnosis TTE TEE ICE 3D 4D Evaluation of Cardiac Anatomy Hemodynamic
More informationLesson 02: Sound Wave Production. This lesson contains 24 slides plus 11 multiple-choice questions.
Lesson 02: Sound Wave Production This lesson contains 24 slides plus 11 multiple-choice questions. Accompanying text for the slides in this lesson can be found on pages 2 through 7 in the textbook: ULTRASOUND
More informationUltrasound & Artifacts
ISSN 2005-7881 Journal of Neurosonology 3(Suppl. 2):1-17, 2011 Ultrasound & Artifacts Siryung Han The Catholic University of Korea Artifacts False image- echoes without anatomic correlate US image dose
More informationChapter 4. Pulse Echo Imaging. where: d = distance v = velocity t = time
Chapter 4 Pulse Echo Imaging Ultrasound imaging systems are based on the principle of pulse echo imaging. These systems require the use of short pulses of ultrasound to create two-dimensional, sectional
More informationNuove tecnologie per ecografia ad ultrasuoni: da 2D a 4D
DINFO Dipartimento di Ingegneria dell Informazione Department of Information Engineering Nuove tecnologie per ecografia ad ultrasuoni: da 2D a 4D Piero Tortoli Microelectronics Systems Design Lab 1 Introduction
More informationPulsed VNA Measurements:
Pulsed VNA Measurements: The Need to Null! January 21, 2004 presented by: Loren Betts Copyright 2004 Agilent Technologies, Inc. Agenda Pulsed RF Devices Pulsed Signal Domains VNA Spectral Nulling Measurement
More informationPhysics of ultrasound
1 Physics of ultrasound Basic principles Nature of ultrasound Sound = longitudinal, mechanical wave particles move parallel to direction of travel Audible sound < 20 khz Ultrasound > 20 khz Sound cannot
More informationDoppler in Obstetrics: book by K Nicolaides, G Rizzo, K Hecher. Chapter on Doppler ultrasound: principles and practice by Colin Deane
Doppler in Obstetrics: book by K Nicolaides, G Rizzo, K Hecher Chapter on Doppler ultrasound: principles and practice by Colin Deane INTRODUCTION Competent use of Doppler ultrasound techniques requires
More informationQuick Reference Guide
siemens.com/nx3 Quick Reference Guide ACUSON NX3 Series Contents 2 System Overview 3 Getting Started 8 2D Mode and M-mode 12 Color and Spectral Doppler 24 Measurements and Calculations 38 Text, Arrows
More informationUltrasound Physics. History: Ultrasound 2/13/2019. Ultrasound
Ultrasound Physics History: Ultrasound Ultrasound 1942: Dr. Karl Theodore Dussik transmission ultrasound investigation of the brain 1949-51: Holmes and Howry subject submerged in water tank to achieve
More informationDOPPLER RADAR. Doppler Velocities - The Doppler shift. if φ 0 = 0, then φ = 4π. where
Q: How does the radar get velocity information on the particles? DOPPLER RADAR Doppler Velocities - The Doppler shift Simple Example: Measures a Doppler shift - change in frequency of radiation due to
More informationLesson 06: Pulse-echo Imaging and Display Modes. These lessons contain 26 slides plus 15 multiple-choice questions.
Lesson 06: Pulse-echo Imaging and Display Modes These lessons contain 26 slides plus 15 multiple-choice questions. These lesson were derived from pages 26 through 32 in the textbook: ULTRASOUND IMAGING
More informationThe physics of ultrasound. Dr Graeme Taylor Guy s & St Thomas NHS Trust
The physics of ultrasound Dr Graeme Taylor Guy s & St Thomas NHS Trust Physics & Instrumentation Modern ultrasound equipment is continually evolving This talk will cover the basics What will be covered?
More informationEENG473 Mobile Communications Module 3 : Week # (12) Mobile Radio Propagation: Small-Scale Path Loss
EENG473 Mobile Communications Module 3 : Week # (12) Mobile Radio Propagation: Small-Scale Path Loss Introduction Small-scale fading is used to describe the rapid fluctuation of the amplitude of a radio
More informationLecture 3 SIGNAL PROCESSING
Lecture 3 SIGNAL PROCESSING Pulse Width t Pulse Train Spectrum of Pulse Train Spacing between Spectral Lines =PRF -1/t 1/t -PRF/2 PRF/2 Maximum Doppler shift giving unambiguous results should be with in
More informationDC-6. Diagnostic Ultrasound System
DC-6 Diagnostic Ultrasound System DC-6 is a general purpose color Doppler ultrasound system aiming at most clinical areas both in exam and research with various transducers and multi software packages
More informationM5 Diagnostic Ultrasound System
V0807 M5 Diagnostic Ultrasound System Mindray s ultrasound family is now introducing a new member, M5 hand-carried color Doppler system. M5, coming in a laptop size with comprehensive ergonomic design,
More informationFREQUENTLY ASKED QUESTIONS
FREQUENTLY ASKED S Q9: Expanding aperture is a technique in ultrasound beamforming where the objects very close to the aperture are imaged by a lower number of aperture elements. That is, as the depth
More informationGET10B Radar Measurement Basics- Spectrum Analysis of Pulsed Signals. Copyright 2001 Agilent Technologies, Inc.
GET10B Radar Measurement Basics- Spectrum Analysis of Pulsed Signals Copyright 2001 Agilent Technologies, Inc. Agenda: Power Measurements Module #1: Introduction Module #2: Power Measurements Module #3:
More informationPhased Array Velocity Sensor Operational Advantages and Data Analysis
Phased Array Velocity Sensor Operational Advantages and Data Analysis Matt Burdyny, Omer Poroy and Dr. Peter Spain Abstract - In recent years the underwater navigation industry has expanded into more diverse
More informationPresented By : Lance Clayton AOC - Aardvark Roost
Future Naval Electronic Support (ES) For a Changing Maritime Role A-TEMP-009-1 ISSUE 002 Presented By : Lance Clayton AOC - Aardvark Roost ES as part of Electronic Warfare Electronic Warfare ES (Electronic
More informationRadar-Verfahren und -Signalverarbeitung
Radar-Verfahren und -Signalverarbeitung - Lesson 2: RADAR FUNDAMENTALS I Hon.-Prof. Dr.-Ing. Joachim Ender Head of Fraunhoferinstitut für Hochfrequenzphysik and Radartechnik FHR Neuenahrer Str. 20, 53343
More informationLow wavenumber reflectors
Low wavenumber reflectors Low wavenumber reflectors John C. Bancroft ABSTRACT A numerical modelling environment was created to accurately evaluate reflections from a D interface that has a smooth transition
More informationThe Physics of Echo. The Physics of Echo. The Physics of Echo Is there pericardial calcification? 9/30/13
Basic Ultrasound Physics Kirk Spencer MD Speaker has no disclosures to make Sound Audible range 20Khz Medical ultrasound Megahertz range Advantages of imaging with ultrasound Directed as a beam Tomographic
More informationUltrasound Imaging Ultr Michael Dadd 2007
Ultrasound Imaging Ultrasound Physics & Instrumentation - Recommended Reading 1. Diagnostic Ultrasound: Principles and Instruments (7th Ed) Frederick W Kremkau W B Saunders Company 2. Applied Physics &
More informationAdvanced signal processing methods for planewave color Doppler ultrasound imaging
Western University Scholarship@Western Electronic Thesis and Dissertation Repository May 2017 Advanced signal processing methods for planewave color Doppler ultrasound imaging Omar Mansour The University
More informationUltrasound Transducers for Q+ Systems
Analogic Ultrasound Product Specifications Ultrasound Transducers for Q+ Systems 00.050.231, Revision A, May 9, 2014 US Patents 6,216,029-6,325,759-6,558,326-6,911,008-7,274,325-8,088,070-8,556,815 - D654,178
More informationVR5-HD Functionality Verification Procedure. Application Note
VR5-HD Functionality Verification Procedure Application Note Spirent 541 Industrial Way West Eatontown, NJ 07724 USA Email: sales@spirent.com Web: http://www.spirent.com AMERICAS 1-800-SPIRENT +1-818-676-2683
More informationCharacterization of a Very Shallow Water Acoustic Communication Channel MTS/IEEE OCEANS 09 Biloxi, MS
Characterization of a Very Shallow Water Acoustic Communication Channel MTS/IEEE OCEANS 09 Biloxi, MS Brian Borowski Stevens Institute of Technology Departments of Computer Science and Electrical and Computer
More informationIncoherent Scatter Experiment Parameters
Incoherent Scatter Experiment Parameters At a fundamental level, we must select Waveform type Inter-pulse period (IPP) or pulse repetition frequency (PRF) Our choices will be dictated by the desired measurement
More informationCONTENTS. User Manual
Document revision: Rev 1 Ref. AS-156-101 January 2013 CONTENTS 1 General... 5 2 Instrument description... 6 3 LED indicator... 7 4 Using the instrument... 7 5 Technical specification... 9 6 Dynamic performance...
More informationUltrasonics. Introduction
Ultrasonics Introduction Ultrasonics is the term used to describe those sound waves whose frequency is above the audible range of human ear upward from approximately 20kHz to several MHz. The ultrasonics
More informationMAKING TRANSIENT ANTENNA MEASUREMENTS
MAKING TRANSIENT ANTENNA MEASUREMENTS Roger Dygert, Steven R. Nichols MI Technologies, 1125 Satellite Boulevard, Suite 100 Suwanee, GA 30024-4629 ABSTRACT In addition to steady state performance, antennas
More informationB. Cavity-Enhanced Absorption Spectroscopy (CEAS)
B. Cavity-Enhanced Absorption Spectroscopy (CEAS) CEAS is also known as ICOS (integrated cavity output spectroscopy). Developed in 1998 (Engeln et al.; O Keefe et al.) In cavity ringdown spectroscopy,
More informationACUSON X150 Knobology & User Guide
ACUSON X150 Knobology & User Guide ACUSON X150 CONTROL PANEL Table of Contents The ACUSON X150 knobology and user guide is the clinicians quick reference of system terms, functions and capabilities. This
More informationBYU SAR: A LOW COST COMPACT SYNTHETIC APERTURE RADAR
BYU SAR: A LOW COST COMPACT SYNTHETIC APERTURE RADAR David G. Long, Bryan Jarrett, David V. Arnold, Jorge Cano ABSTRACT Synthetic Aperture Radar (SAR) systems are typically very complex and expensive.
More informationTechnician License Course Chapter 2. Lesson Plan Module 2 Radio Signals and Waves
Technician License Course Chapter 2 Lesson Plan Module 2 Radio Signals and Waves The Basic Radio Station What Happens During Radio Communication? Transmitting (sending a signal): Information (voice, data,
More informationTORSTEIN PEDERSEN. Improving the Common DVL: A New Standard in Doppler Velocity Logs
TORSTEIN PEDERSEN Improving the Common DVL: A New Standard in Doppler Velocity Logs VOLVO OCEAN RACE 2011 Precursor to Nortek s DVL story Nortek Background for DVLs Technology Company with expertise in
More informationPART I: The questions in Part I refer to the aliasing portion of the procedure as outlined in the lab manual.
Lab. #1 Signal Processing & Spectral Analysis Name: Date: Section / Group: NOTE: To help you correctly answer many of the following questions, it may be useful to actually run the cases outlined in the
More informationCHAPTER 3 THE DESIGN OF TRANSMISSION LOSS SUITE AND EXPERIMENTAL DETAILS
35 CHAPTER 3 THE DESIGN OF TRANSMISSION LOSS SUITE AND EXPERIMENTAL DETAILS 3.1 INTRODUCTION This chapter deals with the details of the design and construction of transmission loss suite, measurement details
More informationLecture 6 SIGNAL PROCESSING. Radar Signal Processing Dr. Aamer Iqbal Bhatti. Dr. Aamer Iqbal Bhatti
Lecture 6 SIGNAL PROCESSING Signal Reception Receiver Bandwidth Pulse Shape Power Relation Beam Width Pulse Repetition Frequency Antenna Gain Radar Cross Section of Target. Signal-to-noise ratio Receiver
More informationMicroscopic Laser Doppler Vibrometer
Microscopic Laser Doppler Vibrometer System Configuration - 1 PC Controller (APU-Analog processing unit, DPU-Digital processing unit) Optic Head (MEMS Type, XS Type) Function Generator Power Supply Testing
More informationUltrasound Physics and Instrumentation, 5e Chapter 7: Level 1 Quiz Answers. 1) Which of the following is stated in the introduction of the chapter?
Ultrasound Physics and Instrumentation, 5e Chapter 7: Level 1 Quiz Answers 1) Which of the following is stated in the introduction of the chapter? a) Because of the importance of Doppler, this chapter
More informationMedical Imaging (EL582/BE620/GA4426)
Medical Imaging (EL582/BE620/GA4426) Jonathan Mamou, PhD Riverside Research Lizzi Center for Biomedical Engineering New York, NY jmamou@riversideresearch.org On behalf of Prof. Daniel Turnbull Outline
More informationLecture Topics. Doppler CW Radar System, FM-CW Radar System, Moving Target Indication Radar System, and Pulsed Doppler Radar System
Lecture Topics Doppler CW Radar System, FM-CW Radar System, Moving Target Indication Radar System, and Pulsed Doppler Radar System 1 Remember that: An EM wave is a function of both space and time e.g.
More informationKongsberg Maritime Product overview
Kongsberg Maritime Product overview / 1 / 1-Nov-12 Frequency Range Coverage 125,250,500kHz 0.5-200m 12xD 200-400kHz 0.5-500m 5.5xD / 140-200 deg 300 khz 0.5-270m 4-10xD / 130-200 deg 70-100 khz 3-2000m
More informationSpectral Velocity Estimation using the Autocorrelation Function and Sparse Data Sequences
Spectral Velocity Estimation using the Autocorrelation Function and Sparse Data Sequences Jørgen Arendt Jensen Ørsted DTU, Build. 348, Technical University of Denmark, DK-8 Lyngby, Denmark Abstract Ultrasound
More informationRadar Systems Engineering Lecture 12 Clutter Rejection
Radar Systems Engineering Lecture 12 Clutter Rejection Part 1 - Basics and Moving Target Indication Dr. Robert M. O Donnell Guest Lecturer Radar Systems Course 1 Block Diagram of Radar System Transmitter
More informationHIGH FREQUENCY INTENSITY FLUCTUATIONS
Proceedings of the Seventh European Conference on Underwater Acoustics, ECUA 004 Delft, The Netherlands 5-8 July, 004 HIGH FREQUENCY INTENSITY FLUCTUATIONS S.D. Lutz, D.L. Bradley, and R.L. Culver Steven
More informationDoppler Ultrasound Blood Flow Measurement System for Assessing Coronary Revascularization
Doppler Ultrasound Blood Flow Measurement System for Assessing Coronary Revascularization J. Solano 1, M. Fuentes 1, A. Villar 2 J. Prohias 2, F. García-Nocetti 1 1 Universidad Nacional Autónoma de México,
More information1 V NAME. Clock Pulse. Unipolar NRZ NRZ AMI NRZ HDB3
NAME ES 442 Homework #9 (Spring 208 Due May 7, 208 ) Print out homework and do work on the printed pages.. Problem High Density Bipolar 3 (HDB3) (20 points) HDB3 is a line code developed to avoid long
More informationPN9000 PULSED CARRIER MEASUREMENTS
The specialist of Phase noise Measurements PN9000 PULSED CARRIER MEASUREMENTS Carrier frequency: 2.7 GHz - PRF: 5 khz Duty cycle: 1% Page 1 / 12 Introduction When measuring a pulse modulated signal the
More informationSet No.1. Code No: R
Set No.1 IV B.Tech. I Semester Regular Examinations, November -2008 RADAR SYSTEMS ( Common to Electronics & Communication Engineering and Electronics & Telematics) Time: 3 hours Max Marks: 80 Answer any
More information(12) United States Patent (10) Patent No.: US 6,390,983 B1. MO et al. (45) Date of Patent: May 21, 2002
USOO6390983B1 (12) United States Patent (10) Patent No.: MO et al. (45) Date of Patent: May 21, 2002 (54) METHOD AND APPARATUS FOR (56) References Cited AUTOMATIC MUTING OF DOPPLER NOISE INDUCED BY ULTRASOUND
More informationOcean SAR altimetry. from SIRAL2 on CryoSat2 to Poseidon-4 on Jason-CS
Ocean SAR altimetry from SIRAL2 on CryoSat2 to Poseidon-4 on Jason-CS Template reference : 100181670S-EN L. Phalippou, F. Demeestere SAR Altimetry EGM NOC, Southampton, 26 June 2013 History of SAR altimetry
More informationCoherent Marine Radar. Measurements of Ocean Wave Spectra and Surface Currents
Measurements of Ocean Wave Spectra and Surface Currents Dennis Trizna Imaging Science Research, Inc. dennis @ isr-sensing.com Presentation Outline: Introduction: Standard Marine Radar vs. Single Image
More informationMSAN-001 X-Band Microwave Motion Sensor Module Application Note
1. Introduction HB Series of microwave motion sensor modules are X-Band Mono-static DRO Doppler transceiver front-end module. These modules are designed for movement detection. They can be used in intruder
More informationIntroduction to Medical Engineering (Medical Imaging) Ultrasound Imaging. Ho Kyung Kim Pusan National University
Introduction to Medical Engineering (Medical Imaging) Suetens 6 Ultrasound Imaging Ho Kyung Kim Pusan National University Sound Sonic: 20 Hz 20 khz (audible frequency) Subsonic () Ultrasound
More informationDC-6 Expert. Diagnostic Ultrasound System
DC-6 Expert Diagnostic Ultrasound System MINDRAY has newly released DC-6 Expert, a general purpose color Doppler ultrasound system with full ergonomic designs, supplying more accessible exams, higher imaging
More informationSpace Frequency Coordination Group
Space Frequency Coordination Group Report SFCG 38-1 POTENTIAL RFI TO EESS (ACTIVE) CLOUD PROFILE RADARS IN 94.0-94.1 GHZ FREQUENCY BAND FROM OTHER SERVICES Abstract This new SFCG report analyzes potential
More informationExplain what is meant by a photon and state one of its main properties [2]
1 (a) A patient has an X-ray scan taken in hospital. The high-energy X-ray photons interact with the atoms inside the body of the patient. Explain what is meant by a photon and state one of its main properties....
More informationA bluffer s guide to Radar
A bluffer s guide to Radar Andy French December 2009 We may produce at will, from a sending station, an electrical effect in any particular region of the globe; (with which) we may determine the relative
More information12/26/2017. Alberto Ardon M.D.
Alberto Ardon M.D. 1 Preparatory Work Ultrasound Physics http://www.nysora.com/mobile/regionalanesthesia/foundations-of-us-guided-nerve-blockstechniques/index.1.html Basic Ultrasound Handling https://www.youtube.com/watch?v=q2otukhrruc
More informationLesson 06: Pulse-echo Imaging and Display Modes. This lesson contains 22 slides plus 15 multiple-choice questions.
Lesson 06: Pulse-echo Imaging and Display Modes This lesson contains 22 slides plus 15 multiple-choice questions. Accompanying text for the slides in this lesson can be found on pages 26 through 32 in
More information: PT Philips Indonesia CERTIFICATE OF PRODUCTION SOLE AGENT/ DISTRIBUTOR : NA CERTIFICATE OF DISTRIBUTION (PAK)
SOLE AGENT/ DISTRIBUTOR : PT Philips Indonesia CERTIFICATE OF PRODUCTION : NA CERTIFICATE OF DISTRIBUTION (PAK) : HK.07.Alkes/IV/625/AK.2.2012 ADDRESS : Jl. Buncit Raya Kav 99-100, Pasar Minggu, Jak-Sel
More informationBlood Flow Analysis Using Ultrasound Doppler Technique
IOSR Journal of Electronics and Communication Engineering (IOSR-JECE) e-issn: 2278-2834,p- ISSN: 2278-8735.Volume 10, Issue 5, Ver. I (Sep - Oct.2015), PP 31-35 www.iosrjournals.org Blood Flow Analysis
More informationinter.noise 2000 The 29th International Congress and Exhibition on Noise Control Engineering August 2000, Nice, FRANCE
Copyright SFA - InterNoise 2000 1 inter.noise 2000 The 29th International Congress and Exhibition on Noise Control Engineering 27-30 August 2000, Nice, FRANCE I-INCE Classification: 7.2 MICROPHONE T-ARRAY
More informationTransport and Aerospace Engineering. Deniss Brodņevs 1, Igors Smirnovs 2. Riga Technical University, Latvia
ISSN 2255-9876 (online) ISSN 2255-968X (print) December 2016, vol. 3, pp. 52 61 doi: 10.1515/tae-2016-0007 https://www.degruyter.com/view/j/tae Experimental Proof of the Characteristics of Short-Range
More informationProblems from the 3 rd edition
(2.1-1) Find the energies of the signals: a) sin t, 0 t π b) sin t, 0 t π c) 2 sin t, 0 t π d) sin (t-2π), 2π t 4π Problems from the 3 rd edition Comment on the effect on energy of sign change, time shifting
More informationVHF Radar Target Detection in the Presence of Clutter *
BULGARIAN ACADEMY OF SCIENCES CYBERNETICS AND INFORMATION TECHNOLOGIES Volume 6, No 1 Sofia 2006 VHF Radar Target Detection in the Presence of Clutter * Boriana Vassileva Institute for Parallel Processing,
More informationCoded Ultrasound for Blood Flow Estimation Using Subband Processing
IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control, vol. 55, no. 10, October 2008 2211 Coded Ultrasound for Blood Flow Estimation Using Subband Processing Fredrik Gran, Jesper Udesen,
More informationLecture 21. Wind Lidar (3) Direct Detection Doppler Lidar
Lecture 21. Wind Lidar (3) Direct Detection Doppler Lidar Overview of Direct Detection Doppler Lidar (DDL) Resonance fluorescence DDL Fringe imaging DDL Scanning FPI DDL FPI edge-filter DDL Absorption
More informationSimulation the Hybrid Combinations of 24GHz and 77GHz Automotive Radar
Simulation the Hybrid Combinations of 4GHz and 77GHz Automotive Radar Yahya S. H. Khraisat Electrical and Electronics Department Al-Huson University College/ Al-Balqa' AppliedUniversity P.O. Box 5, 5,
More informationWaves and Sound Practice Test 43 points total Free- response part: [27 points]
Name Waves and Sound Practice Test 43 points total Free- response part: [27 points] 1. To demonstrate standing waves, one end of a string is attached to a tuning fork with frequency 120 Hz. The other end
More informationAgilent Pulsed Measurements Using Narrowband Detection and a Standard PNA Series Network Analyzer
Agilent Pulsed Measurements Using Narrowband Detection and a Standard PNA Series Network Analyzer White Paper Contents Introduction... 2 Pulsed Signals... 3 Pulsed Measurement Technique... 5 Narrowband
More informationTransfer Function (TRF)
(TRF) Module of the KLIPPEL R&D SYSTEM S7 FEATURES Combines linear and nonlinear measurements Provides impulse response and energy-time curve (ETC) Measures linear transfer function and harmonic distortions
More informationTransducers Product Specification Sheet
Transducers Product Specification Sheet 00.050.134, Rev A Ultrasonix Medical Corporation, All Rights Reserved. 00.050.134, Rev A Descriptions and availability are subject to change without notice. Please
More informationWaveform Encoding - PCM. BY: Dr.AHMED ALKHAYYAT. Chapter Two
Chapter Two Layout: 1. Introduction. 2. Pulse Code Modulation (PCM). 3. Differential Pulse Code Modulation (DPCM). 4. Delta modulation. 5. Adaptive delta modulation. 6. Sigma Delta Modulation (SDM). 7.
More informationTransmission Impairments
1/13 Transmission Impairments Surasak Sanguanpong nguan@ku.ac.th http://www.cpe.ku.ac.th/~nguan Last updated: 11 July 2000 Transmissions Impairments 1/13 Type of impairments 2/13 Attenuation Delay distortion
More informationGeneral MIMO Framework for Multipath Exploitation in Through-the-Wall Radar Imaging
General MIMO Framework for Multipath Exploitation in Through-the-Wall Radar Imaging Michael Leigsnering, Technische Universität Darmstadt Fauzia Ahmad, Villanova University Moeness G. Amin, Villanova University
More informationTime and Frequency Domain Windowing of LFM Pulses Mark A. Richards
Time and Frequency Domain Mark A. Richards September 29, 26 1 Frequency Domain Windowing of LFM Waveforms in Fundamentals of Radar Signal Processing Section 4.7.1 of [1] discusses the reduction of time
More informationTHE USE OF VOLUME VELOCITY SOURCE IN TRANSFER MEASUREMENTS
THE USE OF VOLUME VELOITY SOURE IN TRANSFER MEASUREMENTS N. Møller, S. Gade and J. Hald Brüel & Kjær Sound and Vibration Measurements A/S DK850 Nærum, Denmark nbmoller@bksv.com Abstract In the automotive
More informationAn Introduction to FFT EMI Receivers
An Introduction to FFT EMI Receivers Introduction An evolution in EMI receiver design is underway to take advantage of today s digital signal processing (DSP) technologies, using fast Fourier transform
More informationNON-AMPLIFIED PHOTODETECTOR USER S GUIDE
NON-AMPLIFIED PHOTODETECTOR USER S GUIDE Thank you for purchasing your Non-amplified Photodetector. This user s guide will help answer any questions you may have regarding the safe use and optimal operation
More informationDOPPLER EFFECT IN THE CW FM SONAR JACEK MARSZAL, ROMAN SALAMON, KRZYSZTOF ZACHARIASZ, ALEKSANDER SCHMIDT
DOPPLER EFFEC IN HE CW FM SONAR JACEK MARSZAL, ROMAN SALAMON, KRZYSZOF ZACHARIASZ, ALEKSANDER SCHMID Gdansk University of echnology 11/12, G. Narutowicza St., 8-233 Gdansk, Poland jacek.marszal@eti.pg.gda.pl
More informationWaves transfer energy NOT matter Two categories of waves Mechanical Waves require a medium (matter) to transfer wave energy Electromagnetic waves no
1 Waves transfer energy NOT matter Two categories of waves Mechanical Waves require a medium (matter) to transfer wave energy Electromagnetic waves no medium required to transfer wave energy 2 Mechanical
More informationNon-amplified Photodetectors
Non-amplified Photodetectors User Guide (800)697-6782 sales@eotech.com www.eotech.com Page 1 of 9 EOT NON-AMPLIFIED PHOTODETECTOR USER S GUIDE Thank you for purchasing your Non-amplified Photodetector
More informationFrequency Domain Representation of Signals
Frequency Domain Representation of Signals The Discrete Fourier Transform (DFT) of a sampled time domain waveform x n x 0, x 1,..., x 1 is a set of Fourier Coefficients whose samples are 1 n0 X k X0, X
More informationPRINCIPLES OF METEOROLOCIAL RADAR
PRINCIPLES OF METEOROLOCIAL RADAR OUTLINE OVERVIEW Sampling R max Superrefraction, subrefraction, operational impacts Sidelobes Beam Width Range Folding PRF s (Pulse Repition Frequency) PRECIPITATION ESTIMATES
More information(A) 2f (B) 2 f (C) f ( D) 2 (E) 2
1. A small vibrating object S moves across the surface of a ripple tank producing the wave fronts shown above. The wave fronts move with speed v. The object is traveling in what direction and with what
More informationRF-based Internet-of-Thing (IoT) Techniques Kate C.-J. Lin Academia Sinica
RF-based Internet-of-Thing (IoT) Techniques Kate C.-J. Lin Academia Sinica! 2015.05.29 Localization! Object Tracking! Gesture Detection! Human Computer Interaction! Health Care See through walls [sigcomm
More informationA COMPACT SYSTEM WITH ADVANCED PERFORMANCE
Samsung Medison is a global leading medical devices company. Founded in 1985, the company sells cutting-edge diagnostic ultrasound devices around the world in various medical fields. The company has attracted
More information