RED - Main Frame. Series 500 Greenhouse Kit w/blackout System, Ventilation & Evaporative Cooling

Size: px
Start display at page:

Download "RED - Main Frame. Series 500 Greenhouse Kit w/blackout System, Ventilation & Evaporative Cooling"

Transcription

1 Series 500 Greenhouse Kit w/blackout System, Ventilation & Evaporative Cooling RED - Main Frame 2017 Growers Supply All Rights Reserved. Reproduction is prohibited without permission. Revision date: GB30PVRED 30' Wide Series 500 Greenhouse Framing Kit: All Standard Lengths. 1

2 Color Coding READ THIS BEFORE YOU BEGIN Purchased greenhouse and all accessories & systems require a specific installation sequence. All components have been separated into different categories based on common grouping and/or the chronology of installation. Each category has been color coded. All parts within any given color category will be labeled accordingly, and each color category will have its own respective instruction manual. The following illustrates a highly recommended order in which all components should be installed. IMPORTANT: There are some procedures that can occur simultaneously, depending on available assistants and equipment, but there are some procedures that MUST be done in chronological order. Before you begin, review below step recommendation and all technical documents to better understand overall building kit design. 1 RED - MAIN FRAME (Rafters, Purlins, Chord Support and Cabling) 2 3 ORANGE - END WALL FRAMING (Columns, Cross Beams and Door Framing) BLUE - END WALL CLADDING (Polycarbonate, Termination and Flashing) 4 GREEN - ROOF CLADDING (Film, Inflation Kits and Termination) PINK - AIR DISTRIBUTION (Fan, Vent Tube and Shutter) YELLOW - EVAPORATIVE COOLING (Framing, Cooling Pads and Plumbing) BROWN - END WALL VENT (Framing, Motor and Drive Shaft) WHITE - VENTILATION (Exhaust Fans, Ceiling Fans and Light Traps) PURPLE - STATIC BLACKOUT (Monofilament, Fixation and Sealing) BLACK - MOVABLE BLACKOUT (Fabric, Leading Edge, Motor and Drive Shaft) GRAY - BLACKOUT SIDE POCKET (Framing and Polycarbonate) Near the beginning of each color-coded instruction guide, you will find information to lead you through the installation and assembly steps. This information identifies at what point during the assembly the respective components are installed or attached to the main building frame. Since we cannot anticipate changes made by the customer/contractor, all instructions assume the use of accessories purchased from us to be used on the building the accessory was designed for. Each instruction guide presents the basic steps to install the color-coded components. When in doubt, consult the services of a qualified contractor experienced with the assembly of similar structures. 2 Revision date:

3 Color Coding RED Main Frame Installation Chronology MUST READ: All components that are color coded RED represent the main frame of the greenhouse. These components MUST be installed completely before any other color-coded component is installed. Gather all components that have been color coded with a RED label or paint splotch, and continue on the next page with the main frame installation. Revision date:

4 Important Information READ THIS DOCUMENT BEFORE YOU BEGIN Thank you for purchasing a Series 500 greenhouse kit with a black-out system, ventilation & evaporative cooling. When properly assembled and maintained, this product will provide years of reliable service. These instructions include helpful hints and important information needed to safely assemble and properly maintain the structure. Please read these instructions before you begin. If you have any questions during the assembly, please contact customer service for assistance. SAFETY PRECAUTIONS Wear eye protection. Wear head protection. Wear gloves when handling metal parts. Use a portable GFCI (Ground Fault Circuit Interrupter) when working with power tools and cords. Do not climb on the frame during or after construction. Do not occupy the structure during high winds, tornadoes, or hurricanes. Provide adequate ventilation if the structure is enclosed. Do not store hazardous materials in the structure. Provide proper ingress and egress to prevent entrapment. NEVER hang items from the system components! SETTING THE GROUND POSTS/BASE PLATES The frame assembly of this building requires the setting of all ground post in concrete, or base plates on concrete. Review the layout diagrams for additional details. LOCATION Choosing the proper location is an important step before you begin. The following suggestions and precautions will help determine whether your selected location is best. Always check local building codes before you begin and follow codes as instructed. Never erect the structure under power lines. Identify whether underground cables and pipes are present before preparing the site, setting ground posts or anchoring the structure. Location should be away from structures that could cause snow to drift on or around the building. Do not position the structure where large loads such as snow and ice, large tree branches, or other overhead obstacles could fall. SITE After choosing a location, proper preparation of the site is essential. Follow the information below. A level site is required. The site must be level to properly and safely erect and anchor the structure. Drainage: Water draining off the structure and from areas surrounding the site should drain away from the site to prevent damage to the site, structure, and contents of the structure. WARNING: Those assembling this structure are responsible for designing and furnishing all temporary bracing, shoring and support needed during assembly. For safety reasons, those who are not familiar with recognized construction methods and techniques must seek the help of a qualified contractor. WIND AND SNOW LOAD Many GrowSpan shelters and greenhouses can be designed to meet wind and snow loading in your area. Please consult with your account manager if needed for additional information. Enlist the services of a professional and competent contractor to prepare the site and set the ground posts. Failing to secure ground posts or base plates in concrete as required may result in damage to the building, building contents, and surrounding property. 4 Revision date:

5 Important Information ANCHORING THE BUILDING The anchoring methods shown in this manual for buildings with base plates or buildings with ground posts are temporary in nature. For the recommended permanent anchoring methods, consult the MUST READ documents that also shipped with your building. The diagrams presented in that guide show anchoring methods designed to meet typical loads and forces. Consult that document and read its contents before you begin construction. ASSEMBLY Following the instructions as presented will help ensure proper assembly. Failing to follow these steps may result in an improperly assembled and anchored structure. IMPORTANT: There are some procedures that can occur simultaneously, depending on available assistants and equipment, but there are some procedures that MUST be done in chronological order. Before you begin, review all technical documents to better understand overall building design. The steps outlining the basic frame assembly are as follows: 1. Verify that all parts are included in the shipment. Notify Customer Service for questions or concerns. 2. Read this guide and all additional documentation included with the shipment before you begin. 3. Gather the tools, bracing, ladders, lifts, and assistants needed to assemble the structure. 4. Check the weather before you install the roof cover and any end panels (if equipped). Do not install covers or panels on a windy or stormy day. 5. Re-evaluate the location and site based on the information and precautions presented in the documentation included with the shipment. 6. Prepare the site (if applicable) and set the ground posts in concrete. If building includes end framing, review those instructions and drawings for additional end framing requirements. 7. Assemble rafter components and rafter support components. 8. Assemble main building frame (rafters, cabling, purlins etc). 9. If used, attach baseboards (customer-supplied). REQUIRED TOOLS The following list identifies the main tools needed to assemble the greenhouse kit. Additional tools and supports may be needed depending on the structure, system, location, conditions and application. Tape measure or measuring device and marker to mark locations on the pipes and rafters. Variable speed drills and impact drivers. (Cordless with extra batteries works best.) Metal-cutting saws or tools to cut pipe and aluminum. Drill bit set Wrenches and impact socket set, hammer, and gloves. Adjustable pliers and self-locking pliers. 4mm Hex wrench to tighten set screws Level 6' (or longer) preferred String line (or chalk line) Square to check vent frame during assembly Scissors or utility knife Ladders, work platforms, and other machinery for lifting designed to work safely at the height of the building. Safety equipment to protect head, eyes, hands and feet. UNPACK AND IDENTIFY PARTS The following steps will ensure that you have all the necessary parts before you begin to assemble the shelter frame. 1. Unpack the contents of the shipment and place where you can easily inventory the parts. Refer to the Bill of Materials/Spec Sheets. 2. Verify that all parts listed on the Bill of Materials/ Spec Sheets are present. If anything is missing or you have questions, consult the Pictorial Parts Guide and all diagrams for clarification, or contact Customer Service. NOTE: Do not open plastic bags containing smaller parts such as fasteners or washers at this time. Simply verify quantity. Revision date:

6 Parts Identification The following graphics will help identify the basic parts of the frame. (Some parts are not shown.) FA4482B Tek Screw Magnetic Nut Setter Square Band Clamp Band Clamp AS2167 Anchor Shackle End Rafter (Base Plates Only) Mid Rafter (Base Plates Only) Cross Connector QH1070 Pipe Strap Cable Bracket PGBRKAAS01 Bracket Turnbuckle 6 Revision date:

7 Overview GrowSpan Series 500 Greenhouse Frame OVERVIEW This section describes assembling your building frame. See illustration below to identify main parts. 1. Prepare site and set the ground posts/base plates in or on concrete. 2. Locate the required parts for each assembly procedure. 3. Assemble the rafters and main frame. Drawing may show a model of a different length. Refer to Technical Documents located near the back of this guide for on-center measurements and post layout. Interior Rafter Ridge Purlin End Rafter Webbing Strut Cable Ground Post On-center Vertical Header Ground Level Side Purlin Rafter Support Chord Revision date:

8 Prepare and Square the Building Site prepare the Building Site A level site is required to accurately and safely construct the building. Consult the services of a qualified contractor to properly grade and prepare the site. Site should slope away from the building for proper water drainage. After the site is prepared, mark the location of the frame corners to square the frame position. Taking these steps before assembling the shelter saves time and ensures that the structure is square and positioned as desired. Square the Site: General steps 1. Identify a corner where a building rafter will be positioned, drive in a stake, and string a line the exact width of the building and stake in place. (Width of the rafter is measured from center-to-center of the rafter legs.) 2. After the first corner stake is in place, string a line the width of the building (center-to-center) and drive the second corner stake into the ground. 3. String a line at least as long as the building 90 from the line between the first and second stakes. The following procedures are suggested methods. Their use depends on the size of the shelter, shelter application, base plates (if applicable), and the method used to anchor the shelter. When in doubt, consult the services of a qualified contractor experienced with the construction of similar structures. Ground Posts If the frame includes ground posts, set all ground posts as described within this manual. Width of the shelter is measured from the center of one ground post to the center of the remaining ground post. Length is also measured center-to-center. If the frame includes ground posts, continue with the Set Ground Post section. Review the layout diagrams for additional details. Enlist the services of a professional and competent contractor to prepare the site and set the ground posts. Failing to secure ground posts in concrete as required may result in damage to the building, building contents, and surrounding property. Rafter Base Plates If your frame includes base plates, prepare the site and anchor the plates to the site before assembling the frame. Read the following information and use the diagram to layout the position of your building. Once the string lines are set to mark the location, continue with the Base Plates section. Unless you are securing plates to concrete piers, do not dig holes if your building is equipped with rafter base plates! Read the information on the Base Plate Installation (if equipped) page for additional details. NOTE: A transit can be used to ensure an accurate 90 angle, or the rule can be used. Refer to diagram. Using multiples of such as or helps to maintain an accurate 90 angle. 4. After squaring the position of the building, measure the length and drive the third corner stake. 5. Repeat the same step for the last corner stake. NOTE: The distance measured diagonally between corner stakes must be equal for the building to be square. 6. If purchased greenhouse includes ground posts, continue with the "Set Ground Posts" section on the following page. If purchased greenhouse includes base plates, skip to the "Base Plate Installation" pages. NOTE: If attaching base plates to a slab, consult and follow local and regional building codes for slab requirements. 8 Revision date:

9 Set Ground Posts MARK the Site AND DIG POST HOLES These steps describe marking all post hole locations and digging the holes. For some sites, it may not be possible to complete the procedure in this manner. An alternative procedure such as working from one end of the building toward the other may be necessary. Determine the best procedure based on the site and other factors and proceed as needed. NOTE: Refer to the Quick Start Section located near the back of these instructions for the Side Profile and related diagrams. Complete these steps: 1. Stake the outline of the building using string line and batter boards. Set batter boards 3' back from the building corners. Check to ensure that the building layout is square. Cover or panels (if equipped) will not install properly if the building frame is not square once assembled. 2. Consult the diagrams in the Quick Start section to verify the frame length and width dimensions and to accurately position the ground posts. 3. Guided by the string line, use a flag or stake to mark each ground post hole location. 4. Move the string line and dig a post hole a minimum of two feet (2') deep or to a depth that is below the geographic frost line. Consult local building codes. A power auger works best. Minimum hole diameter is 12". 5. After digging all holes, reattach the string line to the batter boards and use it as a guide to set and align the ground posts. Drawing may show layout of a different length. Refer to Quick Start section located in the back of these instructions for on-center measurements and post layout for your frame. on-center on-center on-center on-center Revision date:

10 Set Ground Posts SET ground Posts Required parts and equipment: Ground Posts (113334) and Band Clamps Equipment to level and brace posts NOTE: Concrete (customer-supplied) is required to secure all ground post in the holes. Set all posts at the same height for proper assembly. Position all rafter mounting holes to point toward the ends of the frame. Stake Ground Posts for Concrete Rafter mounting holes point towards ends. Set all posts at the same height. Additional bracing may be needed to keep the post plumb while concrete sets. Consult the services of a qualified contractor to properly set posts. Here are the basic steps: 1. Take one ground post, measure 24" from the end opposite the single bolt hole, and mark the location on the ground post. Repeat to mark all ground posts. NOTE: The single rafter mounting bolt hole is to the top of the ground post. Position the two pre-drilled holes in the ground post toward the ground. 2. With assistance, brace all posts in place. See diagram below. All posts to be plumb before adding concrete. Use the baseboard mounting holes and customersupplied fasteners and stakes to hold posts in place. 3. Add concrete to anchor posts in holes. Fill hole so concrete remains below the finished grade. Customer-supplied braces and fasteners. Finished Grade Set top of posts at the same height. Posts set in concrete 24" below finished grade. SETTING THE GROUND POSTS The ground posts include pre-drilled rafter mounting bolt holes and holes to attach the baseboards. Position rafter mounting holes so they point to the ends of the frame. Baseboard attachment holes will then be positioned to point to the outside/inside of the frame. 10 Revision date:

11 Set the Ground Posts Ground Level Ground Post 2 Deep Concrete In areas where frost is common, dig each post hole so it falls below the frost line. Minimum hole depth for all areas regardless of frost is 24". Minimum hole diameter is 12". Set all ground posts 24" below finished grade. Consult local building codes and qualified contractors for additional details when digging the post holes and setting the ground posts. Follow established codes and construction practices. Optional: Before setting the posts, drill a hole through the bottom of each ground post 2"-3" from the end and insert a 6"-8" length of rebar through it. This will help stabilize and anchor the ground posts once the concrete sets. CONCRETE PIER 12" Revision date:

12 Base Plate Installation Setting the Base plates For buildings equipped with base plates, secure the plates to either a concrete foundation or concrete piers prior to attaching the rafter legs and assembling the frame. Customer is responsible for construction of the necessary concrete foundation or concrete piers. Consult and follow local and regional building codes for slab requirements. Once concrete has cured, attach base plates. Ensure base plates are aligned and spaced according to layout diagram in Quick Start section located near the back of this guide. Attach using the appropriate mounting hardware (purchased separately). Plates must be aligned, plumb, and set at correct, uniform height for proper assembly. ATTENTION: Slide two (2) band clamps over each base plate of first two rafters at each end for side cable attachment. See circles below. Two (2) clamps. Two (2) clamps. Frame length may differ from diagram shown. Two (2) clamps here. Two (2) clamps here. 6' On-Center ATTENTION: Enlist the services of a qualified contractor to properly layout and set base plates. Diagrams not to scale. General Anchor Bolt and Epoxy Installation Steps: 1. Determine on-center position of base plate. Mark center of plate and mark oncenter position of plate on foundation. Consult layout in technical documents. 2. Square plate on foundation, align marks, and mark bolt hole locations using base as a template Corner Base Plate Align Marks Concrete Mid Base Plate Align Marks Concrete 3. Remove base plate and drill mounting holes according to requirements of anchor bolts. 4. Clean bolt holes according to anchor bolt specifications and the directions on epoxy container. 5. Once holes are clean, set plate back in place and apply recommended epoxy into each hole as described by epoxy manufacturer. 6. Take anchor bolts (with nuts and washers installed) and carefully insert one into each bolt hole. Adjust nut and washer on anchor bolt to gauge how far bolt will drop into hole. 7. Allow epoxy to set according to manufacturer's instructions before tightening. 8. Repeat procedure to install remainder of base plates. 9. After epoxy has set, return to all anchor bolts and tighten according to manufacturer's instructions. 12 Revision date:

13 Rafter Assembly RAFTER ASSEMBLY After setting the ground posts/base plates, continue with the rafter assembly. Do not set assembled rafters into position on the ground posts until concrete has set (if applicable). Check with contractor for set times. NOTE: All rafter assemblies consist of three main rafter sections. Consult the rafter diagrams in the technical documents at the end of these instructions before and during the rafter assembly process for details. Assistance is required to assemble the rafters and frame. Assemble all main sections of rafters as described below and set aside. PG500TC2316S301 PG500TC2316S302 Align pre-drilled holes at peak. PG500TC23G16S03 PG500TC23G16S03 30' Wide Rafter STEP 1: Select the rafter pipes to assemble one rafter. STEP 2: Slide the separate pipe pieces together. STEP 3: Secure each rafter joint using two (2) FA4482B Tek screws. STEP 4: Wrap each splice and Tek screws with duct tape or stucco tape to protect the cover. Revision date:

14 RAFTER ASSEMBLY Support Chords Rafter Assembly Support Chords Support chord assemblies act as the horizontal surface to which black-out panels are attached, and against which the black-out panels seal. Additionally, support chord assemblies provide the structural support to support the weight of the black-out system components. SEE FOLLOWING PAGE FOR ASSEMBLY DETAILS. Complete these basic steps: 1. Slide the band clamps into position on the assembled rafter. 2. Assemble the 2"x2" square chord tube using inserts. Do not secure splices yet. 3. Slide square band clamps onto the chord tube. 4. Secure each splice of the chord tube using FAG363B bolts, FAME08B washers, FAMA38B lock washers, and FALB04B nuts. See next page. 5. Attach a U-bracket to each end of the assembled chord tube using FAG363B bolts, FAME08B washers, FAMA38B lock washers, and FALB04B nuts. See next page. 6. Attach assembled chord to the rafter using: FAG365B (3/8") bolts, FAME08B washers, FAMA38B lock washers, and FALB04B nuts. See next page. 7. Verify dimensions and position of support chord components and install web strut components. 8. Return to each band clamp and secure each clamp to the rafter using a Tek screw. Install Tek screw in a position that will not contact the cover or shade panels when they are installed. See next page. ATTENTION: Support chord components are NOT installed in the end rafters. The first rafter with the support chord assembly is the 3rd rafter from the front end and then every other rafter, or every 12' from there, as shown. 12' 12' 5th Rafter 3rd Rafter Actual frame may differ from frame shown in diagrams. Example shows a 48' long frame. Applications are the same. Adjust accordingly. 14 Revision date:

15 Rafter Assembly Support Chords BAND CLAMP (103856) BAND CLAMP (103856) BAND CLAMP (103856) DETAIL C BAND CLAMP (103856) DETAIL A WEB (ST05050D13G17S1) WEB (ST08475D13G17S1) WEB (ST08475D13G17S1 ) DETAIL D WEB (ST05050D13G17S1) BAND CLAMP(106735) CHORD TUBE (S20P126G14SGA) DETAIL B CHORD TUBE (S20P07237G14SS1) BAND CLAMP (106735) BAND CLAMP(106735) CHORD TUBE(S20P126G14SGA) DETAIL A DETAIL B RAFTER (1x) 3/8" X 3-1/2" HEX BOLT (1x) 3/8" LOCK WASHER (1x) 3/8" HEX NUT (4x) 3/8" X 3" HEX BOLT (4x) 3/8" WASHER (4x) 3/8" LOCK WASHER (4x) 3/8" HEX NUT (1x) 3/8" X 1" HEX BOLT (1x) 3/8" LOCK WASHER 2" SQ TUBE INSERT [115187] CROSS BEAM U-BRACKET [115181] CROSS BEAM CROSS BEAM DETAIL C WEB DETAIL D BAND CLAMP (103856) BAND CLAMP (106735) RAFTER (1X) #14 X 1" TEK SCREW WEB WEB WEB (1X) 5/16" X 1-1/2" CARRIAGE BOLT (1X) 5/16" NUT (1X) #14 X 1" TEK SCREW CROSS BEAM Revision date:

16 Frame Assembly FRAME ASSEMBLY Use the diagrams and information that follows to assemble the main frame. ATTENTION: Rafters are heavy. Always lift rafter from two separate points to prevent damage and injury. Examine the site to determine the best way to move the rafters into position and to set them onto the ends of each set of ground posts. Do not set rafters into position until the ground post concrete has set. Optional, but recommended especially for long buildings: Build a Rafter-Spacing Jig (Customer supplies materials.) A spacing jig saves time and helps to evenly space the rafters. Jig sets the on-center spacing of rafters. Examine the photo below and use it to build a jig to space rafters during purlin installation. Use 2" x 4" lumber and wood fasteners. Customer-supplied rafter-spacing jig. ATTENTION: Anchor the first rafter in place using bracing or rope/cable. Do not allow the first rafter to stand without bracing until additional rafters are set and purlins are installed. Connect rafter to ground post/base plate using: FAG363B (3/8") bolts, FAME08B washers, & FALB04B nuts. NOTE: Diagram shows ground posts. Actual frame may include base plates. All applications are the same. Adjust accordingly. (2) Clamps (2) Clamps Rope or Cable (2) Clamps (2) Clamps Finished Grade Slide two band clamps over each of the first two ground posts/base plates at each end of the frame. 16 Revision date:

17 Frame Assembly FRAME ASSEMBLY (continued) Use this diagram to properly position the purlins during the frame assembly. Side purlins will run just above the chord tubes of the rafter chord support components. Secure upper side purlins at 15'6" above the finished grade. Secure purlin using QH1070 pipe straps at each end rafter. Use cross connectors at each mid rafter position. Center the ridge purlin on top of the rafters. Secure using the QH1070 and FA4482 Tek screws. Install one Tek screw through the side of the strap and into the purlin pipe. Approximately 11' Approximately 15'6" Secure lower side purlins at 11' above the finished grade. Secure purlin using QH1070 pipe straps at each end rafter. Use cross connectors at each mid rafter position. Finished Grade Revision date:

18 Frame Assembly FRAME ASSEMBLY (continued) After setting the first end rafter and bracing it in place, set the second rafter and add the purlins and purlin clamps. Consult the techincal diagrams for connection details. Purlin Pipe After the first few rafters are set and connected by purlins, remove the end rafter bracing and continue with the frame assembly. Purlin Pipe IMPORTANT! Secure each QH1070 pipe strap to the purlin pipe using one Tek screw. Secure all cross connectors to the rafter and to the purlin pipe using Tek screws. Secure all purlin pipe splices using two Tek screws. See photos on next page. 18 Revision date:

19 Frame Assembly FRAME ASSEMBLY (continued) End Rafter QH1070 Pipe Strap Purlin FA4482B Tek Screw Purlin FA4482B Tek Screw FA4482B Tek Screw Photo shows the installation of the side purlin and pipe strap at the end rafter. See Connection Details in Quick Start section for additional information. Ridge purlin is installed on top of the rafters unless noted. Secure each QH1070 pipe strap to the purlin pipe using one Tek screw. Purlin Pipe #2 FA4482B Tek Screws Cross Connector Purlin Purlin Pipe #1 End of Purlin Pipe #2 inside #1 Purlin Pipe Splice Mid Rafter (Between End Rafters) Secure all cross connectors to the rafter and to the purlin pipe using Tek screws. Secure each purlin pipe splice using two Tek screws. HELPFUL HINT: Wrap all rafter connections with a layer of duct tape or provided stucco tape (115199) as shown to prevent edges from damaging the greenhouse film cover. Revision date:

20 Frame Assembly FRAME ASSEMBLY (continued) Customer-supplied rafter-spacing jig. 20 Revision date:

21 Frame Assembly FRAME ASSEMBLY (continued) Frame length may differ from diagrams shown. Frame with Ground Post Option (No Rafter Support Components) CABLE ASSEMBLY AND INSTALLATION IS SHOWN IN A LATER PROCEDURE. Frame with Ground Post and Rafter Support Components Frame with Base Plates Option (No Rafter Support Components) NOTE: Some frames may also include support components on end rafters. These examples do not. Revision date:

22 Baseboard Installation Recommended BASEBOARD INSTALLATION RECOMMENDED Gather the parts: 2" x 8" treated lumber (supplied by customer). 5/16" carriage bolts and nuts supplied by customer. Length depends on the thickness of the baseboard. A customer-supplied baseboard is recommended for greenhouse film termination. A baseboard runs the length of the frame and provides a seal between the finished grade and the termination spring channel. When properly installed, baseboard runs the length of the frame at ground level. The baseboard is supplied by the customer. The following procedure describes one way to install the baseboards. The size and type of the baseboard you choose may require the use of alternative steps. Baseboard Finished Grade Ground Posts and Baseboard The above diagrams present examples only. Actual installation depends on customer-supplied materials and other factors. On the outside of the frame, attach the first baseboard to the rafter using two (2) 5/16" carriage bolts and nuts. Countersink bolt heads if carriage bolts are not used. Continue adding baseboards to complete the first run. Splices are made between posts as shown in the drawing below. Use a short section of baseboard to secure separate baseboards at a splice. See diagram below. Repeat steps to install the second run of baseboard on the remaining side of the frame. NOTE: The boards should be at ground level or slightly into grade to create a good seal between the board and finished grade. After installing the baseboards, continue with these instructions. Inside of Shelter Splice 5/16" Nuts Finished Grade 5/16" Carriage Bolts Outside of Shelter 22 Revision date:

23 Diagonal Cable Installation Using the diagrams and photos, install diagonal cables at each end bay of the frame. Position turnbuckle either at the top end of the cable assembly, or at the bottom end (for easier adjustment) as shown in the photos on the next page. Secure each band clamp to the rafter using a Tek screw. Install Tek screw in a location that will not contact film cover when it is installed. Apply duct tape over band clamp on top of rafters to protect film. PGBRKAAS01 Bracket Shackle Turnbuckle Cable Cable PGBRKAAS01 Bracket CABLE ASSEMBLY PART NUMBERS END BAYS (SIDEWALL) CAB25G0702 MID BAYS (ROOF) CAB25G Turnbuckle AS2167 Anchor Shackle Complete these steps: PGBRKAAS01 Bracket 1. Consult the Cable Assembly table above and choose a cable for the end bay sidewall location. Verify on-center rafter spacing to ensure correct cable is selected. 2. Construct a cable assembly using the components shown in the cable diagrams above. Ensure shackle is tighten after installation. 3. Fully open turnbuckle. Threads of threaded jaw should remain fully in turnbuckle body when properly opened. See below. End of Rod Body Photo shows installation of end bay sidewall diagonal cable assemblies with turnbuckles at the lower end. Revision date:

24 Diagonal Cable Installation CABLE ASSEMBLY AND INSTALLATION (continued) 4. For end bay sidewall cables, secure the upper band clamp 3"- 4" below the clamp of the lower purlin run. (See A below.) A 3"- 4" Purlin Clamp Steps 4 & 5 Lower Purlin Run A Lower Purlin Run B Band Clamp AS2167 shackle attached to crimped cable end. PGBRKAATS01 bracket attached to band clamp. Sample frame (above) showing installed cables. Frame has ground posts. Dashed lines show ground level. Steps 6 & 7 B ATTENTION: If band clamps were not installed as described on Pages 12 and 16, install those now. 5. Take cable assembly and attach one end to the band clamp. Depending on preference, attach either end to the band clamp. 6. Take remaining end of the cable assembly and use it to judge the position of the lower band clamp, which will be approximately 3'-8". Mark position on rafter and secure lower band clamp to rafter using a Tek screw. See B at the right. 7. Attach cable assembly to band clamp. 8. Repeat Steps 1-7 to construct and install the remaining seven (7) end bay sidewall cables. 9. Check to ensure each band clamp is secured to rafter tube using a Tek screw. Tape over clamp to protect film when it is installed. 10. Return to all cable turnbuckles and hand-tighten until snug to remove all slack. DO NOT OVER TIGHTEN CABLES. 11. Continue with the construction and installation of diagonal roof cables. See next page. Turnbuckle installed at the lower end of cable assembly and attached directly to bracket. Band Clamp Secure band clamp to pipe. Lower photos show attaching the PGBRKAAS01 bracket to the installed band clamp. 24 Revision date:

25 Diagonal Cable Installation In addition to the end bay sidewall diagonal cables, this frame includes mid bay roof diagonal cable assemblies. Consult the technical documents near the back of this guide for all connection details. See Cable Assembly table on Page 23 for cable part number. PARTS TO ASSEMBLE AND INSTALL MID BAY CABLES IMPORTANT: Review all connection detail diagrams in the technical documents to better understand how to install these cable assemblies and brackets. FAME18B 3/8" Washers FALB04B 3/8" Nuts FAG365B 3/8" x 3-1/2" Bolt A A Turnbuckle B B AS2167 Anchor Shackle Cable Bracket PROCEDURE 1: INSTALL CABLE BRACKETS Unlike end bay sidewall diagonal cables, mid bay roof cables attach to a angled bracket secured to the rafter using a bolt and nut. Read and understand the following conditions before installing the brackets. Review connection details in technical documents. Install all cable brackets once positions are determined. No Optional Ridge Vent: If no ridge vent is present, secure two (2) brackets there will be two per through-bolt connection (A) using the fasteners noted above. Use the pre-drilled hole at the rafter peak. Optional Ridge Vent present: If a ridge vent is present, attach the cable brackets using the threaded rod for the ridge vent arms in the two (2) mid bay (A) locations. No Rafter Support Kit (See Page 13): If no rafter support components are installed at the rafter where cable bracket is attached (B), secure brackets to the rafter using the fasteners noted above. Use the predrilled hole in rafter. Each (B) location will have one (1) bracket attached. Rafter Support Kit Installed (See Page 13): If rafter support kit components are installed, loosen nut and bolt at each (B) location, add the bracket, and reinstall and tighten nut. ATTENTION: The B locations are identical on opposite side of frame (not shown) on same two rafters. PROCEDURE 2: ATTACH MID BAY CABLES Complete these steps to attach mid bay diagonal cables to the installed angled cable brackets: 1. Consult table on Page 23 for cable part number. Verify on-center rafter spacing to ensure correct cable is selected. 2. Attach an AS2167 shackle to one end of the cable. 3. Fully open a turnbuckle and attach it to the free end of the cable opposite the shackle. Threads of threaded jaw should remain fully in turnbuckle body when properly opened. See below. End of Rod Body 4. Move to the frame and attach cable end with shackle to upper bracket secured to rafter (A) above. 5. Take cable end with turnbuckle and attach turnbuckle to lower bracket (B). 6. Repeat Steps 2-5 to construct and install the three (3) remaining mid bay roof cable assemblies. 7. Return to all turnbuckles and hand-tighten until snug to remove all slack. 8. Continue with the next procedure. Revision date:

26 Install Mid-Rafter Vertical Headers Mid-Rafter Vertical Headers are fixed sections runs of 2"x2" tubing installed just inside the rafter legs at every mid-rafter with a support chord assembly, or every 12'. Intermediate monofilament clips, panel fixation & sealing components, and drive components are all attached to the mid-rafter headers--horizontal and vertical. ASSEMBLE AND INSTALL MID-RAFTER VERTICAL HEADERS Install provided vertical header tubing as shown as every rafter with a support chord assembly. DETAIL A S20P100G14SGB vertical header tube S20P100G14SGB vertical header tube DETAIL B Ground Level DETAIL A FAG363B bolt & FAMA38B lock washer DETAIL B Vertical Header Bracket Rafter Leg FAG355B bolt & FAMA38B lock washer 26 Revision date:

27 Shelter Care and Maintenance FRAME Check Inspect the entire greenhouse frame for sharp edges or fasteners that could damage the cover during installation. 1. Verify that all frame members are properly secured and that all bolts and clamps are tight. 2. Recheck the frame assembly for sharp edges or clamps and bolts that may interfere with the installation of the curtain. File or tape sharp edges as needed. 3. Reposition clamps and bolts as needed and tape all rafter pipe joints with duct tape and/or stucco tape to protect the cover material. 4. Verify that the main building frame is properly and adequately anchored. 5. Clear the site around the building to prepare a staging area for the cover material. SHELTER CARE AND MAINTENANCE Proper care and maintenance of the shelter is important. Check the following items periodically to properly maintain the shelter: Replace all damaged or broken components immediately. Check connections and all fasteners to verify that they remain tight and in good condition. Do not climb or stand on the building at anytime. Inspect the anchoring system to verify that all components remain tight and in good condition. Do not allow the roll-up panel to remain in the open position for extended periods. Lower the panel periodically to allow it to dry and for cleaning. Replace anti-billow rope immediately if worn or broken. Remove debris and objects that accumulate on the building. Use tools that will not damage the cover when removing debris. Remove snow to prevent excess accumulation. Use tools that will not damage the cover when removing snow. Keep heated during non-growing season to prevent snow and ice buildup. Check the contents of the shelter to verify that nothing is touching the cover that could cause damage. If the shelter is dismantled and moved, inspect all parts and connections before using. For replacement or missing parts, call for assistance. NOTE: With the exception of Truss Arch buildings, GrowSpan shelters and buildings do not have any tested loading criteria unless otherwise specified. Revision date:

28 Additional Notes Space below is reserved for customer notes. 28 Revision date:

29 ADDITIONAL INFORMATION THESE PRINTS IDENTIFY AND SHOW THE MAIN COMPONENTS AND CONNECTIONS FOR THIS BUILDING. LENGTH, WIDTH, AND OTHER IMPORTANT DIMENSIONS ARE ALSO PRESENT. TO BEST UNDERSTAND HOW TO CONSTRUCT THIS BUILDING, THE INFORMATION CONTAINED WITHIN THESE SHEETS SHALL BE USED. MOST QUESTIONS THAT ARISE BEFORE AND DURING CONSTRUCTION ARE ANSWERED WITHIN THESE SHEETS. S500 BLACKOUT GREENHOUSE 30' WIDE SERIES 500 BLACKOUT GREENHOUSE GB053036XXXX GB053060XXXX GB053072XXXX GB053084XXXX GB053096XXXX GB XXXX DEVELOPED BY A DIVISION OF ENGINEERING SERVICES & PRODUCTS CO. ORDER #: CUSTOMER #: TH AVENUE SW DYERSVILLE, IA P: F: DOCUMENT CONTENT GUIDE: [A1]... COVER SHEET [B1]... SUPPORT LAYOUT VIEW [C1]... FRONT PROFILE - GROUND POST [C2]... FRONT PROFILE - BASE PLATE [D1]... FRONT PROFILE (DIMENSIONS) [E1]... SIDE PROFILE [F1]... DETAIL LOCATION CALL-OUTS [F2]... CONNECTIONS DETAILS I [F3]... CONNECTIONS DETAILS II [F4]... CABLE CONNECTIONS DETAILS [F5]... PURLIN CONNECTIONS DETAILS [G1]... BASE PLATE LAYOUT & DETAILS [H1]... ENDWALL LOCATION CALL-OUTS [J1]... ENDWALL CONNECTION DETAILS [L1]... BUILDING PROFILE I [L2]... BUILDING PROFILE II [M1]... GLAZING PANEL DETAILS [M2]... GLAZING CONNECTION DETAILS [N1]... AIR DISTRIBUTION CONNECTION DETAILS [N2]... AIR DISTRIBUTION CLADDING DETAILS CUSTOMER INFORMATION: CUSTOMER CONTACT: SHEET TITLE: COVER SHEET STRUCTURE SKU #: GS STRUCTURE SIZE: STRUCTURE DESCRIPTION: 30' WIDE SERIES 500 BLACKOUT GREENHOUSE CONTACT PHONE: DRAWN BY: CCC DRAWING DETAILS CREATION DATE: 6/1/2016 REVISIONS: NO. BY: REVISION DATE: NOTE: 30' X 48' SERIES 500 SHOWN. ACTUAL FRAME MAY DIFFER IN LENGTH NOT TO SCALE SHEET SIZE: 11X17 SHEET: A1

30 RAFTER STYLE END MID SUPPORT A B C LEFT SIDE - SEE BUILDING TECH DOC FOR ELEVATION VIEW DEVELOPED BY A DIVISION OF ENGINEERING SERVICES & PRODUCTS CO TH AVENUE SW DYERSVILLE, IA P: F: ORDER #: RAFTER STYLE: A B C B C B C B A CUSTOMER #: BAY NUMBERS: CUSTOMER INFORMATION: CUSTOMER CONTACT: SHEET TITLE: SUPPORT LAYOUT VIEW FRONT ENDWALL SEE BUILDING TECH DOC FOR ELEVATION VIEW 30'-0" BASE C L BACK ENDWALL: SEE BUILDING TECH DOC FOR ELEVATION VIEW STRUCTURE SKU #: GS CONTACT PHONE: STRUCTURE SIZE: STRUCTURE DESCRIPTION: 30' WIDE SERIES 500 BLACKOUT GREENHOUSE 6'-0" TYP. 48'-0" EXTERIOR RAFTER CHORD CENTERS RIGHT SIDE - SEE BUILDING TECH DOC FOR ELEVATION VIEW NOTE: THIS IS A 48' LONG STRUCTURE SHOWN. THE ACTUAL LENGTH BEING INSTALLED MAY BE DIFFERENT, JUST PATTERN RAFTERS THE SAME. DRAWN BY: CCC NO DRAWING DETAILS NOT TO SCALE CREATION DATE: 6/1/2016 REVISIONS: BY: REVISION DATE: SHEET: B1 SHEET SIZE: 11X17

31 DEVELOPED BY *NOTE: REFER TO [D1] FOR BAND CLAMP LOCATIONS FOR CABLE. FRONT PROFILE - GROUND POST RAFTER (PG500TC2316S301) PIPE STRAP (QH1070) RAFTER (PG500TC2316S302) A DIVISION OF ENGINEERING SERVICES & PRODUCTS CO TH AVENUE SW DYERSVILLE, IA P: F: ORDER #: CUSTOMER #: SPLICE SPLICE /4" PURLIN CENTER TO BOTTOM CLAMP BAND CLAMP (103856)* (IF APPLICABLE) BAND CLAMP (103856)* (IF APPLICABLE) RAFTER (PG500TC23G16S03) 7 RAFTER (PG500TC23G16S03) 6'- 0" SIDEWALL HEIGHT 3'-2" GRADE TO CLAMP BOTTOM BAND CLAMP (103856)* (IF APPLICABLE) 8 BAND CLAMP (103856)* (IF APPLICABLE) GROUND POST (113334) GROUND POST (113334) GROUND LEVEL 7 8 STRUCTURE SKU #: GS STRUCTURE SIZE: STRUCTURE DESCRIPTION: 30' WIDE SERIES 500 BLACKOUT GREENHOUSE 30'-0" CENTER TO CENTER OF GROUND POSTS [C1] VIEW 2 - FRONT PROFILE (RAFTER LAYOUT) ITEM NO. DESCRIPTION QTY. RAFTER A (END) RAFTER B (MID) RAFTER C (SUPPORT) 1 WEB 1 2 N/A N/A ST05050D13G17S1 2 WEB 2 4 N/A N/A ST08475D13G17S1 3 CROSS BEAM MEMBER - END 2 S20P126G14SGA N/A S20P126G14SGA 4 CROSS BEAM MEMBER - MID 1 S20P07237G14SS1 N/A S20P07237G14SS1 5 HEADER U-BRACKET N/A " X 14 GA SQUARE TUBE PLAIN 10" N/A VERTICAL HEADER 2 S20P100G14SGB N/A S20P100G14SGB 8 BOTTOM HEADER BRACKET N/A CLAMP 2.375" FOR H-DUTY STRUT 4 N/A N/A BAND CLAMP FOR 2" SQ 3 N/A N/A PURLIN CONNECTORS 2 QH DRAWN BY: CCC NO CUSTOMER INFORMATION: DRAWING DETAILS NOT TO SCALE CREATION DATE: 6/1/2016 REVISIONS: BY: REVISION DATE: SHEET: CONTACT PHONE: CUSTOMER CONTACT: C1 SHEET TITLE: FRONT PROFILE - GROUND POST SHEET SIZE: 11X17

32 DEVELOPED BY *NOTE: REFER TO [D1] FOR BAND CLAMP LOCATIONS FOR CABLE. FRONT PROFILE - BASE PLATE **NOTE: REFER TO [G1] FOR RAFTER BASE PLATE SKUS. PIPE STRAP (QH1070) A DIVISION OF ENGINEERING SERVICES & PRODUCTS CO TH AVENUE SW DYERSVILLE, IA P: F: RAFTER (PG500TC2316S301) ORDER #: CUSTOMER #: RAFTER (PG500TC2316S302) SPLICE SPLICE /4" PURLIN CENTER TO BOTTOM CLAMP BAND CLAMP (103856)* (IF APPLICABLE) 4 10 BAND CLAMP (103856)* (IF APPLICABLE) 5 5 RAFTER (PG500TC23G16S03) 6'- 0" SIDEWALL HEIGHT 3'-2" GRADE TO CLAMP BOTTOM 7 BAND CLAMP (103856)* (IF APPLICABLE) 8 LEFT BASE PLATE** GROUND LEVEL 30'-0" CENTER TO CENTER OF GROUND POSTS [C2] VIEW 2 - FRONT PROFILE (RAFTER LAYOUT) ITEM NO. DESCRIPTION QTY. RAFTER A (END) RAFTER B (MID) RAFTER C (SUPPORT) 1 WEB 1 2 N/A N/A ST05050D13G17S1 2 WEB 2 4 N/A N/A ST08475D13G17S1 3 CROSS BEAM MEMBER - END 2 S20P126G14SGA N/A S20P126G14SGA BAND CLAMP (103856)* (IF APPLICABLE) RIGHT BASE PLATE** 7 8 RAFTER (PG500TC23G16S03) STRUCTURE SKU #: GS CUSTOMER INFORMATION: STRUCTURE SIZE: CONTACT PHONE: CUSTOMER CONTACT: STRUCTURE DESCRIPTION: 30' WIDE SERIES 500 BLACKOUT GREENHOUSE SHEET TITLE: FRONT PROFILE - BASE PLATE 4 CROSS BEAM MEMBER - MID 1 S20P07237G14SS1 N/A S20P07237G14SS1 5 HEADER U-BRACKET N/A " X 14 GA SQUARE TUBE PLAIN 10" N/A DRAWN BY: CCC DRAWING DETAILS CREATION DATE: 6/1/2016 REVISIONS: 7 VERTICAL HEADER 2 S20P100G14SGB N/A S20P100G14SGB NO. BY: REVISION DATE: 8 BOTTOM HEADER BRACKET N/A CLAMP 2.375" FOR H-DUTY STRUT 4 N/A N/A BAND CLAMP FOR 2" SQ 3 N/A N/A PURLIN CONNECTORS 2 QH NOT TO SCALE SHEET: C2 SHEET SIZE: 11X17

33 DEVELOPED BY NOTE: GREENHOUSE SHOWN WITH GROUND POST. OVER THE TOP = 53'-10" (646") (GRID REPRESENTS 12" SQUARES) FRONT PROFILE (DIMENSIONS) A DIVISION OF ENGINEERING SERVICES & PRODUCTS CO TH AVENUE SW DYERSVILLE, IA P: F: ORDER #: CUSTOMER #: 10'-10 5/8" 10'- 3/8" 6'-0" SIDEWALL HEIGHT 2'-0" EMBEDMENT (FOR GROUND POST APPLICATIONS) GROUND LEVEL 17'-3" GROUND LEVEL TO STRUCTURE PEAK STRUCTURE SKU #: GS CUSTOMER INFORMATION: STRUCTURE SIZE: CONTACT PHONE: CUSTOMER CONTACT: STRUCTURE DESCRIPTION: 30' WIDE SERIES 500 BLACKOUT GREENHOUSE SHEET TITLE: FRONT PROFILE (DIMENSIONS) 30'-0" CENTER TO CENTER OF GROUND POSTS DRAWN BY: CCC DRAWING DETAILS CREATION DATE: 6/1/2016 REVISIONS: NO. BY: REVISION DATE: NOT TO SCALE SHEET SIZE: 11X17 SHEET: D1

34 NOTE: GREENHOUSE SHOWN WITH GROUND POST. SIDE PROFILE DEVELOPED BY PURLINS MID BAY* A DIVISION OF ENGINEERING SERVICES & PRODUCTS CO TH AVENUE SW DYERSVILLE, IA P: F: ORDER #: PURLINS CUSTOMER #: PURLINS 2'-0" EMBEDMENT (FOR GROUND POST APPLICATIONS) END BAY 6'-0" RAFTER SPACING (TYP.) GROUND LEVEL 48'-0" CENTER TO CENTER OF GROUND POSTS END BAY STRUCTURE SKU #: GS STRUCTURE SIZE: CONTACT PHONE: STRUCTURE DESCRIPTION: 30' WIDE SERIES 500 BLACKOUT GREENHOUSE NOTE: 30' X 48' GREENHOUSE SHOWN. ACTUAL FRAME MAY DIFFER IN LENGTH. NOTE: GREENHOUSE SHOWN WITH GROUND POST. *NOTE: MID BAY CABLE IS IN THE TWO CENTER BAYS OF GREENHOUSE. MID BAY CABLE TO ATTACH AT SUPPORT KIT RAFTERS IF APPLICABLE. LATERAL PURLINS BUILDING LENGTH QTY OF PURLIN PIPE 36' 15 (5 RUNS OF 131S147) 48' 20 (5 RUNS OF 131S147) 60' 25 (5 RUNS OF 131S147) 72' 30 (5 RUNS OF 131S147) 84' 35 (5 RUNS OF 131S147) 96' 40 (5 RUNS OF 131S147) 120' 50 (5 RUNS OF 131S147) CABLE ASSEMBLY SKU'S END BAY CAB25G0702 MID BAY CAB25G1706 DRAWN BY: CCC NO CUSTOMER INFORMATION: DRAWING DETAILS NOT TO SCALE CREATION DATE: 6/1/2016 REVISIONS: BY: REVISION DATE: SHEET: CUSTOMER CONTACT: E1 SHEET TITLE: SIDE PROFILE SHEET SIZE: 11X17

35 DEVELOPED BY NOTE: 30' X 48' GREENHOUSE SHOWN. ACTUAL FRAME MAY DIFFER IN LENGTH. DETAIL LOCATION CALL-OUTS NOTE: GREENHOUSE SHOWN WITH GROUND POST. [F2] VIEW 5 RAFTER SPLICE CONNECTION A DIVISION OF ENGINEERING SERVICES & PRODUCTS CO TH AVENUE SW DYERSVILLE, IA P: F: ORDER #: CUSTOMER #: [F3] VIEW 5 VERTICAL HEADER TO CROSS BEAM CONNECTION [F4] VIEW 5 ROOF CABLE TO PEAK PURLIN AT MID RAFTER CONNECTION [F2] VIEW 2 PURLIN/END RAFTER CONNECTION [F3] VIEW 1 WEB TO CROSS BEAM CONNECTION [F3] VIEW 2 WEB TO RAFTER CONNECTION [F3] VIEW 4 CROSS BEAM CONNECTION [F3] VIEW 3 RAFTER TO CROSS BEAM CONNECTION [F4] VIEW 6 CABLE ASSEMBLY [F2] VIEW 1 PURLIN/MID RAFTER CONNECTION [F2] VIEW 3 PURLIN SPLICE CONNECTION [F3] VIEW 6 RAFTER TO VERTICAL HEADER CONNECTION [F2] VIEW 4 RAFTER TO GROUND POST / BASE PLATE CONNECTION [F4] VIEW 4 ROOF CABLE TO PURLIN AT MID RAFTER CONNECTION [F3] VIEW 3 SIDE CABLE TO PURLIN AT END RAFTER CONNECTION [F3] VIEW 1 SIDE CABLE TO GROUND POST CONNECTION STRUCTURE SKU #: GS CUSTOMER INFORMATION: STRUCTURE SIZE: CONTACT PHONE: CUSTOMER CONTACT: STRUCTURE DESCRIPTION: 30' WIDE SERIES 500 BLACKOUT GREENHOUSE SHEET TITLE: DETAIL LOCATION CALL-OUTS [F4] VIEW 2 SIDE CABLE TO PURLIN AT MID RAFTER CONNECTION DRAWN BY: CCC NO DRAWING DETAILS CREATION DATE: 6/1/2016 REVISIONS: BY: REVISION DATE: NOT TO SCALE SHEET SIZE: 11X17 SHEET: F1

36 DEVELOPED BY A DIVISION OF ENGINEERING SERVICES & PRODUCTS CO TH AVENUE SW DYERSVILLE, IA P: F: ORDER #: CUSTOMER #: CROSS CONNECTOR (102546) END RAFTER PURLIN (PURLIN AT THE PEAK IS PLACED ON TOP OF RAFTER) (1X) #14 X 1" TEK SCREW [FA4482B] MID RAFTER (1X) #14 X 1" TEK SCREW [FA4482B] PURLIN PURLIN (1X) #14 X 1" TEK SCREW [FA4482B] PIPE STRAP (QH1070) (3X) #14 X 1" TEK SCREW [FA4482B] PURLIN [F2] VIEW 1 PURLIN/MID RAFTER CONNECTION NOTE: REFERENCE [G1] FOR BASE PLATE LAYOUT. RAFTER [F2] VIEW 2 PURLIN/END RAFTER CONNECTION RAFTER [F2] VIEW 3 PURLIN SPLICE CONNECTION STRUCTURE SKU #: GS STRUCTURE SIZE: STRUCTURE DESCRIPTION: 30' WIDE SERIES 500 BLACKOUT GREENHOUSE RAFTER CONTACT PHONE: - (1X) 3/8" X 3" HEX BOLT [FAG363B] - (1X) 3/8" HEX NUT [FALB04B] - (2X) 3/8" WASHER [FAME08B] (1X) #14 X 1" TEK SCREW [FA4482B] CUSTOMER INFORMATION: CUSTOMER CONTACT: SHEET TITLE: CONNECTION DETAILS I GROUND POST / BASE PLATE DRAWN BY: CCC DRAWING DETAILS CREATION DATE: 6/1/2016 REVISIONS: NO. BY: REVISION DATE: [F2] VIEW 4 RAFTER TO GROUND POST/ BASE PLATE CONNECTION [F2] VIEW 5 RAFTER SPLICE CONNECTION NOT TO SCALE SHEET SIZE: 11X17 SHEET: F2

37 DEVELOPED BY WEB BAND CLAMP (103856) A DIVISION OF ENGINEERING SERVICES & PRODUCTS CO TH AVENUE SW DYERSVILLE, IA P: F: BAND CLAMP (106735) RAFTER RAFTER (1x) 3/8" X 3-1/2" HEX BOLT [FAG365B] (1x) 3/8" LOCK WASHER [FAMA38B] (1x) 3/8" HEX NUT [FALB04B] ORDER #: CUSTOMER #: WEB (1X) #14 X 1" TEK SCREW [FA4482B] (1x) 3/8" X 1" HEX BOLT [FAG355B] (1x) 3/8" LOCK WASHER [FAMA38B] CROSS BEAM (1X) #14 X 1" TEK SCREW [FA4482B] WEB WEB U-BRACKET [115181] (1X) 5/16" X 1-1/2" GALV. CARRIAGE BOLT [FAH317B] (1X) 5/16" GALV. NUT [FALB32B] CROSS BEAM [F3] VIEW 1 WEB TO CROSS BEAM CONNECTION (4x) 3/8" X 3" HEX BOLT [FAG363B] (4x) 3/8" WASHER [FAME08B] (4x) 3/8" LOCK WASHER [FAMA38B] (4x) 3/8" HEX NUT [FALB04B] RAFTER [F3] VIEW 2 WEB TO RAFTER CONNECTION (1x) 3/8" X 3" HEX BOLT [FAG363B] (1x) 3/8" LOCK WASHER [FAMA38B] RAFTER [F3] VIEW 3 RAFTER TO CROSS BEAM CONNECTION VERTICAL HEADER 90 BRACKET [115182] STRUCTURE SKU #: GS STRUCTURE SIZE: CONTACT PHONE: STRUCTURE DESCRIPTION: 30' WIDE SERIES 500 BLACKOUT GREENHOUSE CROSS BEAM 2" SQ TUBE INSERT [115187] CROSS BEAM VERTICAL HEADER (1x) 3/8" X 1" HEX BOLT [FAG355B] (1x) 3/8" LOCK WASHER [FAMA38B] (3x) #14 X 1" TEK SCREW [FA4482B] CUSTOMER INFORMATION: CUSTOMER CONTACT: SHEET TITLE: CONNECTION DETAILS II CROSS BEAM DRAWN BY: CCC DRAWING DETAILS CREATION DATE: 6/1/20163/16/2017 REVISIONS: NO. BY: REVISION DATE: [F3] VIEW 4 CROSS BEAM CONNECTION [F3] VIEW 5 VERTICAL HEADER TO CROSS BEAM CONNECTION [F3] VIEW 6 RAFTER TO VERTICAL HEADER CONNECTION 4 NOT TO SCALE SHEET SIZE: 11X17 SHEET: F3

38 DEVELOPED BY A DIVISION OF ENGINEERING SERVICES & PRODUCTS CO TH AVENUE SW DYERSVILLE, IA P: F: CABLE ASSEMBLY RAFTER RAFTER ORDER #: CUSTOMER #: (1X) #14 X 1" TEK SCREW [FA4482B] PURLIN (1X) #14 X 1" TEK SCREW [FA4482B] PURLIN BAND CLAMP [103856] SHACKLE [AS2167] BAND CLAMP [103856] (1X) #14 X 1" TEK SCREW [FA4482B] CABLE BRACKET [PGBRKAAS01] BAND CLAMP [103856] CABLE BRACKET [PGBRKAAS01] GROUND POST / BASE PLATE CABLE BRACKET [PGBRKAAS01] CABLE ASSEMBLY CABLE ASSEMBLY [F4] VIEW 1 SIDE CABLE TO GROUND POST CONNECTION [F4] VIEW 2 SIDE CABLE TO PURLIN AT MID RAFTER CONNECTION NOTE: OTHER SIDE OF MID BAY CABLE NOT SHOWN FOR CLARITY. PURLIN [F4] VIEW 3 SIDE CABLE TO PURLIN AT END RAFTER CONNECTION TURNBUCKLE (JAW-JAW) STRUCTURE SKU #: GS STRUCTURE SIZE: STRUCTURE DESCRIPTION: 30' WIDE SERIES 500 BLACKOUT GREENHOUSE RAFTER CABLE BRACKET [108503] CABLE ASSEMBLY SHACKLE [AS2167] CABLE ASSEMBLY CABLE BRACKET [108503] RAFTER (1X) 3/8" X 3-1/2" HEX BOLT [FAG365B] (1X) 3/8" WASHER [FAME08B] (1X) 3/8" HEX NUT [FALB04B] THIMBLE (TYP.) NOTE: TURNBUCKLE ATTACHED TO CABLE ASSEMBLY IN FIELD. CABLE SLEEVE (TYP.) CUSTOMER INFORMATION: CONTACT PHONE: CUSTOMER CONTACT: SHEET TITLE: CABLE CONNECTION DETAILS (1X) 3/8" X 3-1/2" HEX BOLT [FAG365B] (1X) 3/8" WASHER [FAME18B] (1X) 3/8" HEX NUT [FALBO4B] DRAWN BY: CCC DRAWING DETAILS CREATION DATE: 6/1/2016 REVISIONS: NO. BY: REVISION DATE: [F4] VIEW 4 ROOF CABLE TO PURLIN AT MID RAFTER CONNECTION [F4] VIEW 5 ROOF CABLE TO PEAK PURLIN AT MID RAFTER CONNECTION [E3] VIEW 6 CABLE ASSEMBLY NOT TO SCALE SHEET SIZE: 11X17 SHEET: F4

39 DEVELOPED BY [F5] VIEW 2 PURLIN TO MID RAFTER A DIVISION OF ENGINEERING SERVICES & PRODUCTS CO TH AVENUE SW DYERSVILLE, IA P: F: [F5] VIEW 5 DIAGONAL PURLIN TO MID RAFTER - (1X) 1/4" THREADED ROD (CUT TO FIT) - (2X) 1/4" WASHER - (2X) 1/4" HEX NUT ORDER #: CUSTOMER #: [F5] VIEW 3 PURLIN TO ENDWALL KEDER* PIPE CLAMP [115177] DIAGONAL PURLIN WILL BE SPLICED TOGETHER USING #14 X 1" TEK SCREWS [FA4482B] CROSS BEAM PURLIN LATERAL PURLINS PURLIN (1x) #14 X 1" TEK SCREW [FA4482B] (AT PURLIN SPLICES) [F5] VIEW 4 DIAGONAL PURLIN TO END RAFTER BUILDING LENGTH QTY OF PURLIN PIPE 36' 6 (2 RUNS OF 105S144) 48' 8 (2 RUNS OF 105S144) 60' 10 (2 RUNS OF 105S144) 72' 12 (2 RUNS OF 105S144) 84' 14 (2 RUNS OF 105S144) 96' 16 (2 RUNS OF 105S144) 120' 18 (2 RUNS OF 105S144) [F5] VIEW 1 PURLIN DETAIL CALLOUTS *NOTE: INSTALL KEDER RAIL BEFORE RUNNING THE PURLINS IF APPLICABLE. *NOTE: INSTALL KEDER RAIL BEFORE RUNNING THE PURLINS IF APPLICABLE. [F5] VIEW 2 PURLIN TO MID RAFTER *NOTE: INSTALL KEDER RAIL BEFORE RUNNING THE PURLINS IF APPLICABLE. (1x) 3/8" X 3" HEX BOLT [FAG363B] (1x) 3/8" LOCK WASHER [FAMA38B] STRUCTURE SKU #: GS STRUCTURE SIZE: STRUCTURE DESCRIPTION: 30' WIDE SERIES 500 BLACKOUT GREENHOUSE CROSS BEAM KEDER* - (1X) 1/4" THREADED ROD (CUT TO FIT) - (2X) 1/4" WASHER - (2X) 1/4" HEX NUT - (1X) 1/4" THREADED ROD (CUT TO FIT) - (2X) 1/4" WASHER - (2X) 1/4" HEX NUT (2x) #14 X 1" TEK SCREW [FA4482B] PURLIN 1.5" X 1.5" SQUARE TUBE [115361] KEDER* 1.5" X 1.5" SQUARE TUBE [115362] CROSS BEAM KEDER* CUSTOMER INFORMATION: CONTACT PHONE: CUSTOMER CONTACT: SHEET TITLE: CABLE CONNECTION DETAILS COLUMN DRAWN BY: CCC DRAWING DETAILS CREATION DATE: 6/1/2016 REVISIONS: NO. BY: REVISION DATE: 1 PURLIN PIPE CLAMP [115177] [F5] VIEW 3 PURLIN TO ENDWALL CROSS BEAM PIPE CLAMP [115177] [F5] VIEW 4 DIAGONAL PURLIN TO END RAFTER CROSS BEAM RAFTER [F5] VIEW 5 DIAGONAL PURLIN TO MID RAFTER NOT TO SCALE SHEET SIZE: 11X17 SHEET: F5

40 DEVELOPED BY *REFER TO SHEET [C2] FOR BASE LOCATIONS RAFTER TYPE LEFT BASE SKU** RIGHT BASE SKU** END MID A DIVISION OF ENGINEERING SERVICES & PRODUCTS CO TH AVENUE SW DYERSVILLE, IA P: F: ORDER #: CUSTOMER #: 6'-0" 6'-0" 4" TYP. 7/8" TYP. TYP. END BAY TYP. MID BAY 5 1/8" TYP. 2 3/16" ISOMETRIC VIEW 2 3/4" TYP. TOP VIEW 30'-2 3/16" 30'-0" RAFTER C L RAFTER C L RAFTER C L RAFTER C L DETAILS 7/8" TYP. STRUCTURE SKU #: GS STRUCTURE SIZE: STRUCTURE DESCRIPTION: 30' WIDE SERIES 500 BLACKOUT GREENHOUSE 8" 2 3/4" 1 1/4" 4 1/8" 2 3/16" ISOMETRIC VIEW CUSTOMER INFORMATION: CONTACT PHONE: CUSTOMER CONTACT: SHEET TITLE: BASE PLATE LAYOUT & DETAILS TOP VIEW DETAILS 'MID & END BASE OPTION' DRAWN BY: CCC NO DRAWING DETAILS NOT TO SCALE CREATION DATE: 6/1/2016 REVISIONS: BY: REVISION DATE: SHEET: G1 SHEET SIZE: 11X17

ClearSpan End Frame Kit 26' Wide x 12' High

ClearSpan End Frame Kit 26' Wide x 12' High ClearSpan End Frame Kit 26' Wide x 12' High Diagram shows the end frame kit for an end wall without a door. (Door and end panel are purchased separately.) Rafter and struts shown in the above diagram are

More information

WHITE - Accessories. Series 500 Greenhouse Kit w/blackout System, Ventilation & Evaporative Cooling

WHITE - Accessories. Series 500 Greenhouse Kit w/blackout System, Ventilation & Evaporative Cooling Series 500 Greenhouse Kit w/blackout System, Ventilation & Evaporative Cooling WHITE - Accessories 2016 Growers Supply All Rights Reserved. Reproduction is prohibited without permission. Revision date:

More information

GrowSpan 30' Wide Series 500 Tall Greenhouses

GrowSpan 30' Wide Series 500 Tall Greenhouses GrowSpan 30' Wide Series 500 Tall Greenhouses Photo may show a building of a different length and style. Frame shown includes optional roll-up sides and customer-supplied baseboards. Building shown is

More information

GrowSpan 42' Wide Series 500 Tall High Tunnels with Roll-Up Sides

GrowSpan 42' Wide Series 500 Tall High Tunnels with Roll-Up Sides GrowSpan 42' Wide Series 500 Tall High Tunnels with Roll-Up Sides Photo may show a building of a different length and style. Frame shown includes drop-down sides and customersupplied baseboards. Actual

More information

GrowSpan 24' Wide Series 500 Tall High Tunnels with Roll-Up Sides

GrowSpan 24' Wide Series 500 Tall High Tunnels with Roll-Up Sides GrowSpan 24' Wide Series 500 Tall High Tunnels with Roll-Up Sides Photo may show a building of a different length and style. Frame shown includes roll-up sides and customer-supplied baseboards. Actual

More information

ClearSpan Mini Grab Bag Shelters

ClearSpan Mini Grab Bag Shelters ClearSpan Mini Grab Bag Shelters Photo may show a different but similar model. Baseboard is not included. 2008 ClearSpan All Rights Reserved. Reproduction is prohibited without permission. STK# DIMENSIONS

More information

ClearSpan End Frame Kit 30' Wide x 11' High

ClearSpan End Frame Kit 30' Wide x 11' High ClearSpan End Frame Kit 30' Wide x 11' High Diagram shows the end frame kit for an end wall without a door. (Door and end panel are purchased separately.) Rafter and mounting feet shown in the above diagram

More information

ClearSpan Mini Cold Frames

ClearSpan Mini Cold Frames ClearSpan Mini Cold Frames Photo may show a different but similar model. 2009 ClearSpan All Rights Reserved. Reproduction is prohibited without permission. STK# DIMENSIONS 105152 6' W x 5' H x 6' L 105153

More information

ClearSpan Mini Grab Bag Shelters

ClearSpan Mini Grab Bag Shelters ClearSpan Mini Grab Bag Shelters Photo may show a different but similar model. Baseboard is not included. 2008 ClearSpan All Rights Reserved. Reproduction is prohibited without permission. STK# DIMENSIONS

More information

ClearSpan Attached-Style Awning

ClearSpan Attached-Style Awning ClearSpan Attached-Style Awning Photo may show a different but similar model. 2007 ClearSpan All Rights Reserved. Reproduction is prohibited without permission. Revision date: July 2007ldg STK# DIMENSIONS

More information

GrowSpan Series 1000 End Wall Cladding Kits

GrowSpan Series 1000 End Wall Cladding Kits GrowSpan Series 1000 End Wall Cladding Kits 30' Wide 2017 FarmTek All Rights Reserved. Reproduction is prohibited without permission. Revision date: 02.16.17 STK# GK1EWC30120G 30' Wide (Twin Wall) Important

More information

GrowSpan Round Cold Frames

GrowSpan Round Cold Frames GrowSpan Round Cold Frames Photo may show a different but similar model. 2016 Growers Supply All Rights Reserved. Reproduction is prohibited without permission. STK# DIMENSIONS 103099 12' W x 8' H x 24'

More information

GrowSpan Series 1000 End Wall Cladding Kits

GrowSpan Series 1000 End Wall Cladding Kits GrowSpan Series 1000 End Wall Cladding Kits 24' Wide 2017 FarmTek All Rights Reserved. Reproduction is prohibited without permission. Revision date: 02.16.17 STK# GK1EWC24120G 24' Wide (Twin Wall) Important

More information

GrowSpan Series 2000 End Wall Cladding Kits

GrowSpan Series 2000 End Wall Cladding Kits GrowSpan Series 2000 End Wall Cladding Kits 35' Wide 2017 FarmTek All Rights Reserved. Reproduction is prohibited without permission. STK# 35' Wide (Twin Wall) Important Information READ THIS DOCUMENT

More information

GrowSpan Series 2000 End Wall Cladding Kits

GrowSpan Series 2000 End Wall Cladding Kits GrowSpan Series 2000 End Wall Cladding Kits 20' Wide 2017 FarmTek All Rights Reserved. Reproduction is prohibited without permission. STK# 20' Wide (Twin Wall) Important Information READ THIS DOCUMENT

More information

Assembly Guide for Series 500 Ridge Vent Kits

Assembly Guide for Series 500 Ridge Vent Kits Assembly Guide for Series 500 Ridge Vent Kits Photo shows a sample ridge vent as installed on a greenhouse. Actual building and ridge vent length may differ. 2014 ClearSpan All Rights Reserved. Reproduction

More information

ClearSpan Grab Bag Canopy

ClearSpan Grab Bag Canopy ClearSpan Grab Bag Canopy Photo may show a different but similar model. 2008 ClearSpan All Rights Reserved. Reproduction is prohibited without permission. STK# DIMENSIONS 104385 10 W x 20 L 1 YOU MUST

More information

WeatherShield Covered Walkway and Connect-A-Building

WeatherShield Covered Walkway and Connect-A-Building WeatherShield Covered Walkway and Connect-A-Building Photo may show a different but similar model. 2014 ClearSpan All Rights Reserved. Reproduction is prohibited without permission. STK# DIMENSIONS 104303

More information

Moo-Tel Small Animal Hut

Moo-Tel Small Animal Hut Moo-Tel Small Animal Hut Photo may show a different but similar model. 2010 ClearSpan All Rights Reserved. Reproduction is prohibited without permission. STK# DIMENSIONS 104602 4 6" W x 4' 10" H x 8 2"

More information

ClearSpan Front Roll-Up Kit Installation Guide

ClearSpan Front Roll-Up Kit Installation Guide ClearSpan Front Roll-Up Kit Installation Guide Roll-up panel opened. Roll-up panel closed. Actual building and panel may differ from what is shown. 2008 ClearSpan All Rights Reserved. Reproduction is prohibited

More information

WeatherShield Daddy Long Legs Canopy

WeatherShield Daddy Long Legs Canopy WeatherShield Daddy Long Legs Canopy Photo may show a different but similar model. 2010 ClearSpan All Rights Reserved. Reproduction is prohibited without permission. Revision date: 06.210 STK# 1220RV10W10

More information

GrowSpan Series 500 Automated Ridge Vent Kits

GrowSpan Series 500 Automated Ridge Vent Kits GrowSpan Series 500 Automated Ridge Vent Kits Photo shows a sample ridge vent as installed on a greenhouse. Actual building and ridge vent length may differ. 2017 Growers Supply All Rights Reserved. Reproduction

More information

GrowSpan Series 500 Door Kits

GrowSpan Series 500 Door Kits GrowSpan Series 500 Door Kits Double Swinging Door Finished Grade Finished Grade Diagram shows a double-swinging door centered and installed in an end wall frame. The door kit includes materials for the

More information

ClearSpan PolyMax Windbreak Wall

ClearSpan PolyMax Windbreak Wall ClearSpan PolyMax Windbreak Wall Photo may show a different but similar model. 2007 ClearSpan All Rights Reserved. Reproduction is prohibited without permission. Revision date: February 2007ldg STK# DIMENSIONS

More information

ClearSpan 20' Wide Free-Standing Building

ClearSpan 20' Wide Free-Standing Building ClearSpan 20' Wide Free-Standing Building Photo may show a different but similar model. 2018 ClearSpan All Rights Reserved. Reproduction is prohibited without permission. STK# PB00580R3/R4 PB00582R3/R4

More information

GrowSpan Series 500 Roll-Up Ends

GrowSpan Series 500 Roll-Up Ends GrowSpan Series 500 Roll-Up Ends Photo may show a different but similar model. Doorframe materials are not included. 2016 Growers Supply All Rights Reserved. Reproduction is prohibited without permission.

More information

ClearSpan Cedar 12' Wide End Frame Kit with Dutch Door

ClearSpan Cedar 12' Wide End Frame Kit with Dutch Door ClearSpan Cedar 12' Wide End Frame Kit with Dutch Door Photo may show a different but similar model. 2010 ClearSpan All Rights Reserved. Reproduction is prohibited without permission. STK # WIDTH 105366

More information

GREEN - Main Frame Film Cladding

GREEN - Main Frame Film Cladding Series 500 Greenhouse Kit w/blackout System GREEN - Main Frame Film Cladding 2017 Growers Supply All Rights Reserved. Reproduction is prohibited without permission. GB30_GREEN 30' Wide Series 500 Main

More information

GrowSpan Gothic Cold Frames

GrowSpan Gothic Cold Frames GrowSpan Gothic Cold Frames Photo may show a different but similar model. 2016 Growers Supply All Rights Reserved. Reproduction is prohibited without permission. STK# DIMENSIONS 106342 30' W x 12' H x

More information

ClearSpan Twin-Wall Polycarbonate End Panel Kit

ClearSpan Twin-Wall Polycarbonate End Panel Kit ClearSpan Twin-Wall Polycarbonate End Kit 30' Wide & 35' Wide Diagram shows a sample end panel kit for a frame. Actual panel positions and sizes for your end panel package may differ from what is shown.

More information

ClearSpan Pro Solar Star Greenhouses

ClearSpan Pro Solar Star Greenhouses ClearSpan Pro Solar Star Greenhouses Double-Layer Greenhouse Film Photo may show a building of a different length. Frame is shown with a roll-up side option and customer-supplied baseboards. End wall is

More information

GrowSpan Estate Pro I Greenhouse

GrowSpan Estate Pro I Greenhouse GrowSpan Estate Pro I Greenhouse Photo may show a different but similar model. 2016 Growers Supply All Rights Reserved. Reproduction is prohibited without permission. STK# DIMENSIONS 104564 11'-8" W x

More information

ClearSpan Pro Solar Star High Tunnels

ClearSpan Pro Solar Star High Tunnels ClearSpan Pro Solar Star High Tunnels Photo may show a building of a different length. Frame is shown with a roll-up side option and customer-supplied baseboards. End wall is not included and requires

More information

Moo-Tel Calf Hutch CLEARSPAN ANIMAL HOUSING W x 12 L W x 18 L W x 24 L

Moo-Tel Calf Hutch CLEARSPAN ANIMAL HOUSING W x 12 L W x 18 L W x 24 L Moo-Tel Calf Hutch Photo may show a different but similar model. 2008 ClearSpan All Rights Reserved. Reproduction is prohibited without permission. STK# DIMENSIONS 102852 14 W x 12 L 102853 14 W x 18 L

More information

ClearSpan Economy Round Style High Tunnel

ClearSpan Economy Round Style High Tunnel ClearSpan Economy Round Style High Tunnel Photo may show a different but similar model. 2012 ClearSpan All Rights Reserved. Reproduction is prohibited without permission. Revision date: 0112 STK# PB01725R6

More information

ClearSpan Pro Solar Star High Tunnels

ClearSpan Pro Solar Star High Tunnels ClearSpan Pro Solar Star High Tunnels Photo may show a building of a different length. Frame is shown with a roll-up side option and customer-supplied baseboards. End wall is not included and requires

More information

ClearSpan Round Style Mini Garage

ClearSpan Round Style Mini Garage ClearSpan Round Style Mini Garage Photo may show a different but similar model. 2008 ClearSpan All Rights Reserved. Reproduction is prohibited without permission. STK# PB01900R4 DIMENSIONS 8' W x 8' H

More information

ClearSpan Corrugated Polycarbonate End Panel Kit

ClearSpan Corrugated Polycarbonate End Panel Kit ClearSpan Corrugated Polycarbonate End Kit 30' Wide & 35' Wide Frame size and layout shown above may differ from actual frame. Photo is used for illustration only. 2010 ClearSpan All Rights Reserved. Reproduction

More information

Premium Solar Star Greenhouse

Premium Solar Star Greenhouse Premium Solar Star Greenhouse Assembly Instructions SKU# 104901 2006 ClearSpan All rights reserved. Reproduction without permission is prohibited. Revision date: March 2006g Contact your sales representative

More information

Sliding Door Kit

Sliding Door Kit YOU MUST READ THIS DOCUMENT BEFORE YOU BEGIN TO ASSEMBLE THE DOOR KIT. Thank you for purchasing this GrowSpan door kit. When properly assembled and maintained, this product will provide years of reliable

More information

ClearSpan Majestic Greenhouse Film Roof with Roll-up Sides

ClearSpan Majestic Greenhouse Film Roof with Roll-up Sides ClearSpan Majestic Greenhouse Film Roof with Roll-up Sides 28' Wide Photo may show a different but similar model. 2009 ClearSpan All Rights Reserved. Reproduction is prohibited without permission. STK#

More information

GrowSpan Round Premium High Tunnels

GrowSpan Round Premium High Tunnels GrowSpan Round Premium High Tunnels Photo may show a different but similar model. 2016 Growers Supply All Rights Reserved. Reproduction is prohibited without permission. STK# PB01680R4 PB01690R4 DIMENSIONS

More information

6' Wide Premium Greenhouse Benches

6' Wide Premium Greenhouse Benches 6' Wide Premium Greenhouse Benches Premium Greenhouse Bench with Stationary Top 2015 FarmTek All Rights Reserved. Reproduction is prohibited without permission. STK# DIMENSIONS 112416S6X08 6' W x 3' H

More information

ClearSpan SolarGuard Round Style Storage Building

ClearSpan SolarGuard Round Style Storage Building ClearSpan SolarGuard Round Style Storage Building Photo may show a different but similar model. 2009 ClearSpan All Rights Reserved. Reproduction is prohibited without permission. Revision date: 131.09

More information

ClearSpan PolyMax Windbreak Wall

ClearSpan PolyMax Windbreak Wall ClearSpan PolyMax Windbreak Wall Photo may show a different but similar model. 2007 ClearSpan All Rights Reserved. Reproduction is prohibited without permission. Revision date: April 2007ldg STK# DIMENSIONS

More information

Breathable Wall Light Traps & Blackout Fan & Shutter Kits

Breathable Wall Light Traps & Blackout Fan & Shutter Kits Breathable Wall Light Traps & Blackout Fan & Shutter Kits 2017 Growers Supply All Rights Reserved. Reproduction is prohibited without permission. Maintain controlled airflow without sacrificing blackout

More information

ClearSpan Majestic Greenhouse Film Roof with Roll-up Sides

ClearSpan Majestic Greenhouse Film Roof with Roll-up Sides ClearSpan Majestic Greenhouse Film Roof with Roll-up Sides 56' Wide Photo may show a different but similar model. 2009 ClearSpan All Rights Reserved. Reproduction is prohibited without permission. STK#

More information

Sliding Door Kit

Sliding Door Kit YOU MUST READ THIS DOCUMENT BEFORE YOU BEGIN TO ASSEMBLE THE DOOR KIT. Thank you for purchasing this GrowSpan door kit. When properly assembled and maintained, this product will provide years of reliable

More information

ClearSpan Open Garages

ClearSpan Open Garages ClearSpan Open Garages Photo may show a different but similar model. 2007 ClearSpan All Rights Reserved. Reproduction is prohibited without permission. STK# PB02910R4 DIMENSIONS 18' W x 16' H x 52' L YOU

More information

GrowSpan Heavy-Duty Commercial Cold Frame

GrowSpan Heavy-Duty Commercial Cold Frame GrowSpan Heavy-Duty Commercial Cold Frame Photo may show a different but similar model. 2018 Growers Supply All Rights Reserved. Reproduction is prohibited without permission. STK# DIMENSIONS 106363 4'

More information

ClearSpan 38' Wide Aircraft Hangar

ClearSpan 38' Wide Aircraft Hangar ClearSpan 38' Wide Aircraft Hangar Photo may show a model of a different length. 2008 ClearSpan All Rights Reserved. Reproduction is prohibited without permission. STK# DIMENSIONS 107556 38' W x 15' H

More information

Blackout Fan Kits with Breathable Wall Light Traps

Blackout Fan Kits with Breathable Wall Light Traps Blackout Fan Kits with Breathable Wall Light Traps 2018 Growers Supply All Rights Reserved. Reproduction is prohibited without permission. Maintain controlled airflow without sacrificing blackout environments.

More information

GrowSpan Round Premium Corrugated Greenhouses

GrowSpan Round Premium Corrugated Greenhouses GrowSpan Round Premium Corrugated Greenhouses Photo may show a different but similar model. 2018 Growers Supply All Rights Reserved. Reproduction is prohibited without permission. STK# DIMENSIONS 104933

More information

GrowSpan Single Swinging Door Black-Out Door Kit

GrowSpan Single Swinging Door Black-Out Door Kit GrowSpan Single Swinging Door Black-Out Door Kit ATTENTION: Door kit includes materials for door only. All other components shown in the diagram above and diagrams throughout this guide are not included

More information

6' Wide Premium Greenhouse Benches

6' Wide Premium Greenhouse Benches 6' Wide Premium Greenhouse Benches Premium Greenhouse Bench with Rolling Top 2015 FarmTek All Rights Reserved. Reproduction is prohibited without permission. STK# DIMENSIONS 112416R6X08 6' W x 3' H x 8'

More information

Blackout Fan Kits with Breathable Wall Light Traps

Blackout Fan Kits with Breathable Wall Light Traps Blackout Fan Kits with Breathable Wall Light Traps 2018 Growers Supply All Rights Reserved. Reproduction is prohibited without permission. Maintain controlled airflow without sacrificing blackout environments.

More information

ClearSpan 34' Wide Aircraft Hangar

ClearSpan 34' Wide Aircraft Hangar ClearSpan 34' Wide Aircraft Hangar Photo may show a model of a different length. 2012 ClearSpan All Rights Reserved. Reproduction is prohibited without permission. STK# DIMENSIONS 107554 34' W x 17' 4"

More information

Blackout Fan Kit with Breathable Wall Light Trap

Blackout Fan Kit with Breathable Wall Light Trap Blackout Fan Kit with Breathable Wall Light Trap 2018 Growers Supply All Rights Reserved. Reproduction is prohibited without permission. Maintain controlled airflow without sacrificing blackout environments.

More information

ClearSpan Majestic Greenhouse Film Roof with Polycarbonate Sides

ClearSpan Majestic Greenhouse Film Roof with Polycarbonate Sides ClearSpan Majestic Greenhouse Film Roof with Polycarbonate Sides 84' Wide Photo may show a different but similar model. 2016 ClearSpan All Rights Reserved. Reproduction is prohibited without permission.

More information

GrowSpan Gothic HobbyPro Greenhouses

GrowSpan Gothic HobbyPro Greenhouses GrowSpan Gothic HobbyPro Greenhouses Photo may show a different but similar model. 2016 Growers Supply All Rights Reserved. Reproduction is prohibited without permission. STK# DIMENSIONS 104889 16 W x

More information

Twin-Wall Double Swinging Door Kit

Twin-Wall Double Swinging Door Kit 115021 Twin-Wall Double Swinging Kit READ THIS DOCUMENT BEFORE YOU BEGIN Thank you for purchasing this GrowSpan door kit. When properly assembled and maintained, this product will provide years of reliable

More information

GrowSpan Round Pro Greenhouses and Systems

GrowSpan Round Pro Greenhouses and Systems GrowSpan Round Pro Greenhouses and Systems Photo may show a different but similar model. 2018 Growers Supply All Rights Reserved. Reproduction is prohibited without permission. STK# DIMENSIONS 104836 14

More information

GrowSpan Gothic Premium Greenhouses

GrowSpan Gothic Premium Greenhouses GrowSpan Gothic Premium Greenhouses Photo may show a different but similar model. 2016 Growers Supply All Rights Reserved. Reproduction is prohibited without permission. STK# DIMENSIONS 106209 16' W x

More information

GrowSpan Gothic Pro Greenhouses and Systems

GrowSpan Gothic Pro Greenhouses and Systems GrowSpan Gothic Pro Greenhouses and Systems Photo may show a different but similar model. Film Cover with Film Roll-Up Side Panels 2016 Growers Supply All Rights Reserved. Reproduction is prohibited without

More information

GrowSpan Gothic Pro Greenhouses and Systems

GrowSpan Gothic Pro Greenhouses and Systems GrowSpan Gothic Pro Greenhouses and Systems Photo may show a different but similar model. Full Polycarbonate Roof Cover and Ends 2016 Growers Supply All Rights Reserved. Reproduction is prohibited without

More information

GrowSpan Round Pro Greenhouses and Systems

GrowSpan Round Pro Greenhouses and Systems GrowSpan Round Pro Greenhouses and Systems Photo may show a different but similar model. 2018 Growers Supply All Rights Reserved. Reproduction is prohibited without permission. STK# DIMENSIONS 104857 26'

More information

GrowSpan Gothic Pro Greenhouses and Systems

GrowSpan Gothic Pro Greenhouses and Systems GrowSpan Gothic Pro Greenhouses and Systems Photo may show a different but similar model. 2017 Growers Supply All Rights Reserved. Reproduction is prohibited without permission. STK# DIMENSIONS 106306

More information

GrowSpan Gothic Pro Greenhouses and Systems

GrowSpan Gothic Pro Greenhouses and Systems GrowSpan Gothic Pro Greenhouses and Systems Photo may show a different but similar model. 2016 Growers Supply All Rights Reserved. Reproduction is prohibited without permission. STK# DIMENSIONS 106314

More information

PASSIVE SOLAR-HEATED GREENHOUSE

PASSIVE SOLAR-HEATED GREENHOUSE PASSIVE SOLAR-HEATED GREENHOUSE Actual greenhouse length may differ from what is shown. SOLAR-HEATED GREENHOUSE Use these instructions for the following greenhouse skus: 106372 (Length: 20') 106373 (Length:

More information

GrowSpan Gothic Premium High Tunnels (All H Models)

GrowSpan Gothic Premium High Tunnels (All H Models) GrowSpan Gothic Premium High Tunnels (All H Models) Ground Level Photo may show a different but similar model. These instructions include information for buildings equipped with either drop-down side curtains

More information

ClearSpan Hydroponic Table Kit

ClearSpan Hydroponic Table Kit ClearSpan Hydroponic Table Kit Hydroponic Table Kit (The 109314 (4' x 16') model is shown.) Designed to grow healthy plants without soil using mineral-nutrient solutions. 2009 ClearSpan All Rights Reserved.

More information

ClearView Panels Mil 3 Finished Sides with Grommets 1 Hem Side Mil 3 Finished Sides with Grommets 1 Hem Side DESCRIPTION

ClearView Panels Mil 3 Finished Sides with Grommets 1 Hem Side Mil 3 Finished Sides with Grommets 1 Hem Side DESCRIPTION ClearView Panels Photo may show a different but similar model. 2006 FarmTek All Rights Reserved. Reproduction is prohibited without permission. Revision date: November 2006rp STK# DESCRIPTION 105659 16

More information

Twin-Wall Double Swinging Door Kit

Twin-Wall Double Swinging Door Kit 105105 Twin-Wall Double Swinging Kit YOU MUST READ THIS DOCUMENT BEFORE YOU BEGIN TO ASSEMBLE THE DOOR KIT. Thank you for purchasing this GrowSpan door kit. When properly assembled and maintained, this

More information

Elite Home-Attached Greenhouse

Elite Home-Attached Greenhouse Elite Home-Attached Greenhouse Photo may show a greenhouse of a different length. Elite Home-Attached Greenhouse Use these instructions for the following greenhouses: #104711 #104713 #104715 2007 ClearSpan

More information

ClearSpan Super Moo-Tel Building 26' Wide

ClearSpan Super Moo-Tel Building 26' Wide ClearSpan Super Moo-Tel Building 26' Wide Photo may show a different but similar model. 2012 ClearSpan All Rights Reserved. Reproduction is prohibited without permission. STK# PB01500R3/R4 PB01510R3/R4

More information

ClearSpan 36' Wide Pony Wall Building

ClearSpan 36' Wide Pony Wall Building ClearSpan 36' Wide Pony Wall Building Ground Level Photo may show a model of a different length. Cover is not shown. 2017 ClearSpan All Rights Reserved. Reproduction is prohibited without permission. STK#

More information

Double Truss Shelter Model# SST W9.14xL14.2xH4.88m Assembly Instructions

Double Truss Shelter Model# SST W9.14xL14.2xH4.88m Assembly Instructions Double Truss Shelter Model# SST304716 W9.14xL14.2xH4.88m Assembly Instructions Page 1 RECOMMENDED TOOLS Equipment List Speed Wrench 22#.23#.24# Hammer (30lb) Rope (12#) Long Tape (50m) Hammer Drill*1 Lifter*2

More information

ClearSpan Twist-of-the-Wrist Assembly Instructions

ClearSpan Twist-of-the-Wrist Assembly Instructions ClearSpan Twist-of-the-Wrist Assembly Instructions Curved-Wall for Roll-Up Side Flat-Wall for Curtain Application 2008 ClearSpan All Rights Reserved. Reproduction is prohibited without permission. Revision

More information

Mini Brute Feed Bunks

Mini Brute Feed Bunks Mini Brute Feed Bunks All Rights Reserved. Reproduction is prohibited without permission. SKU# DIMENSIONS 108260 19" W x 8' L 1 READ THIS DOCUMENT BEFORE YOU BEGIN TO ASSEMBLE THE FEED BUNK. Thank you

More information

Insect Screen for Exhaust Fans

Insect Screen for Exhaust Fans Insect Screen for Exhaust Fans Actual fan and screen kit may differ. 2016 Growers Supply All Rights Reserved. Reproduction is prohibited without permission. STK# 115106F 115107F 115108F DIMENSIONS 24"

More information

ClearSpan Pro Solar Star Greenhouse

ClearSpan Pro Solar Star Greenhouse ClearSpan Pro Solar Star Greenhouse Corrugated Polycarbonate Photo may show a building of a different length. Frame is shown with an option end wall and customersupplied baseboards. End wall is not included

More information

Assembly Guide for Over-The-Top Blackout System

Assembly Guide for Over-The-Top Blackout System Assembly Guide for Over-The-Top Blackout System ATTENTION: This guide describes the assembly and installation of an over-the-top roll-up curtain system. The design flexibility of this curtain system allows

More information

BLACK - Operational Blackout Components

BLACK - Operational Blackout Components Series 500 Greenhouse Kit w/blackout System, Ventilation & Evaporative Cooling BLACK - Operational Blackout Components 2017 Growers Supply All Rights Reserved. Reproduction is prohibited without permission.

More information

Moo-Tel Calf Nurseries

Moo-Tel Calf Nurseries MOO-TEL CALF NUSEIES Moo-Tel Calf Nurseries Photo may show a different but similar model. 2008 ClearSpan All ights eserved. eproduction is prohibited without permission. evision date: 10.13.08 STK# DIMENSIONS

More information

Premium Low-Profile Benches for Dutch Buckets Single Row

Premium Low-Profile Benches for Dutch Buckets Single Row Premium Low-Profile Benches for Dutch Buckets Single Row 2016 Growers Supply All Rights Reserved. Reproduction is prohibited without permission. STK# 115050 12" x 72" 115051 12" x 144" 1 Important Information

More information

ClearSpan Raised Bed Kits

ClearSpan Raised Bed Kits ClearSpan Raised Bed Kits Photo may show a different but similar model. 2010 ClearSpan All Rights Reserved. Reproduction is prohibited without permission. STK# DIMENSIONS TIERS 106457 4' W x 8' L 1 106458

More information

ClearSpan 30' Wide Econoline Storage Building

ClearSpan 30' Wide Econoline Storage Building CLEASPAN POLY BUILDINGS ClearSpan 30' Wide Econoline Storage Building Photo may show a model of a different length. 2008 ClearSpan All ights eserved. eproduction is prohibited without permission. evision

More information

ClearSpan 30' Wide Pony Wall Building

ClearSpan 30' Wide Pony Wall Building CLEASPAN POLY BUILDINGS ClearSpan 30' Wide Pony Wall Building Photo may show a model of a different length. 2015 ClearSpan All ights eserved. eproduction is prohibited without permission. evision date:

More information

Anchor Kit Installation Guide

Anchor Kit Installation Guide Anchor Kit 105587 Installation Guide Use the following photos as guides to identify the rafter leg pipe diameter of your ClearSpan shelter. Install the anchor kit brackets as shown in the photos below.

More information

EZ-Grow Professional Greenhouse Bench

EZ-Grow Professional Greenhouse Bench EZ-Grow Professional Greenhouse Bench Photo may be of a different but similar model. (Bench shown includes the expanded metal top; additional purchase is required for some models.) 2010 ClearSpan All Rights

More information

111628W FodderPro 2.0 Full Feed System Wall Mount

111628W FodderPro 2.0 Full Feed System Wall Mount 111628W FodderPro 2.0 Full Feed System Wall Mount "...grow your own nutrient-rich fodder..." WALL End View Shows Supply Manifold and Channels Side View with Channels and Manifolds Installed 2015 FarmTek

More information

INSTALLATION INSTRUCTIONS 12' x 18' x 7' FRAME (12 x 20 x 7 ROOF COVERAGE) 2 SQUARE CARPORT

INSTALLATION INSTRUCTIONS 12' x 18' x 7' FRAME (12 x 20 x 7 ROOF COVERAGE) 2 SQUARE CARPORT INSTALLATION INSTRUCTIONS 12' x 18' x 7' FRAME (12 x 20 x 7 ROOF COVERAGE) 2 SQUARE CARPORT Our unique assembly process quickly transforms the individual pieces into a finished structure that will give

More information

UNIVERSAL INSTALLATION INSTRUCTIONS FOR CARPORTS

UNIVERSAL INSTALLATION INSTRUCTIONS FOR CARPORTS UNIVERSAL INSTALLATION INSTRUCTIONS FOR CARPORTS FRAME SIZES: WIDTH: 10, 12, 14, 16, 18, 20, 24, AND 30 ON CENTER FRAME SPACING: 4, 4 1/2, AND 5 FRAME LENGTH: 4 ON CENTER 20-2, 4 1/2 ON CENTER 18 AND 5

More information

METHOD STATEMENT FOR THE CONSTRUCTION OF LIGHTWEIGHT HALLS

METHOD STATEMENT FOR THE CONSTRUCTION OF LIGHTWEIGHT HALLS METHOD STATEMENT FOR THE CONSTRUCTION OF LIGHTWEIGHT HALLS General The exact position of the structure has to be established. Please note that the difference in height must not exceed 1.5% in longitudinal

More information

7 X 10 X 6 SHELTER 7 X 16 X 6 SHELTER 12 X 10 X 6 SHELTER 12 X 16 X 6 SHELTER

7 X 10 X 6 SHELTER 7 X 16 X 6 SHELTER 12 X 10 X 6 SHELTER 12 X 16 X 6 SHELTER ASSEMBLY INSTRUCTIONS FOR 7 X 10 X 6 AND 7 X 16 X 6 ATV SPORT SHELTER ACTUAL FRAME SIZES: 7 X 9-1 1/2 X 6 AND 7 X 13-7 1/2 X 6 AND 12 X 10 X 6 AND 12 X 16 X 6 ATV SPORT SHELTER ACTUAL FRAME SIZES: 12 X

More information

10 x 10 Flat Top Two Tone Pergola

10 x 10 Flat Top Two Tone Pergola 0 x 0 Flat Top Two Tone Pergola Models: Bordeaux ASSEMBLY GUIDE OPTIONAL ACCESSORIES Arch Kit System ( Arches) Privacy Fence Panel System ( Panels & Middle Post) Bolt Down Bracket Kit ( for Pergola) Ver.0-00

More information

ASSEMBLY INSTRUCTIONS FOR SOFTOP SHADE COVER

ASSEMBLY INSTRUCTIONS FOR SOFTOP SHADE COVER ASSEMBLY INSTRUCTIONS FOR SOFTOP SHADE COVER Our unique assembly process quickly transforms individual pieces into a finished structure that will give you a lifetime of service. Great care has been taken

More information

Manual for Shelter W3,5xL8,0xH3,8m

Manual for Shelter W3,5xL8,0xH3,8m Manual for Shelter W3,5xL8,0xH3,8m 22-11-2016 Congratulations on your purchase of our instant shelter. This unit is a combination of excellent manufacturing and design. It is comprised of a rigid frame

More information

E-Z GROW HOBBY GREENHOUSE. I n s t r u c t i o n M a n u a l & D i s c l a i m e r s

E-Z GROW HOBBY GREENHOUSE. I n s t r u c t i o n M a n u a l & D i s c l a i m e r s E-Z GROW HOBBY GREENHOUSE I n s t r u c t i o n M a n u a l & D i s c l a i m e r s Contractors/Installers Note: This manual is the property of the customer. Please leave it in the possession of the customer.

More information

10x10 Trellis Pergola

10x10 Trellis Pergola 0x0 Trellis Pergola ASSEMBLY GUIDE Ver.0-7 Table of Contents PAGE Introduction & Overview...................................................... Pergola Materials Overview..............................................................

More information