HIGH SCHOOL ADDITIONS AND RENOVATIONS BRYAN, TEXAS JAMES EARL RUDDER. Checker. Author CHECKED: SCALE: DRAWN: EL201 LEVEL 1 LIGHTING PLAN - CAFETERIA

Size: px
Start display at page:

Download "HIGH SCHOOL ADDITIONS AND RENOVATIONS BRYAN, TEXAS JAMES EARL RUDDER. Checker. Author CHECKED: SCALE: DRAWN: EL201 LEVEL 1 LIGHTING PLAN - CAFETERIA"

Transcription

1 //0 :0:0 PM RYN OUSTON USTINS OLONY PKWY, RYN, TX 0 MMR MMR RUTI WLLR JON STRT MMR MRK MLL MMR VI STSNY SSISTNT SRINTNNT O USINSS SRVIS MS. MY ROZ SRTRY LII NOR J WINSOR ONSTRUTION MNR SSOIT SRINTNNT O TIN & LRNIN PUTY SRINTNNT R. TIMOTY ROK VI PRSINT WILLIM T. "TRY" MOOR RR YRR SRINTNNT R. TOMS. WLLIS MINISTRTION R. OULS WUNNURR OR PRSINT 0-0 OR O TRUSTS VIINITY MP LOTION MP RYN INPNNT SOOL ISTRIT JMS RL RUR I SOOL ITIONS N RNOVTIONS " = '-0" March, 0 YYYY MM SL: ISSU: PROJT OVR ST ST TITL: hecker K: ISSU uthor RWN: JMS RL RUR I SOOL ITIONS N RNOVTIONS RYN, TXS inal Plans for Pemit and idding MP: R NINRS STRUTURL: STNT IVIL: SSNR NINRIN ONSULTNTS: P ST RNWY PLZ SUIT 00 OUSTON, TXS 0

2 NRL 00 PROJT OVR ST 00 RWIN INX O RVIW PLN O RVIW - LSSROOM O RVIW - TRI UL SSMLIS UL SSMLIS / NVLOP OMPLIN K RITTURL SIT S0 OVRLL RITTURL SIT PLN S0 RITTURL SIT MOLTION PLN S0 RITTURL SIT PLN S0 LUMINUM WLKWY OVR PLNS N TILS IVIL 0 SIT PLN 00 MOLITION PLN 00 PVIN, IMNSION, & RIN PLN 00 RIN R MPS 00 UTILITY PLN 00 ROSION ONTROL PLN 00 TILS 0 TILS 0 TILS 0 TILS 0 TILS 0 TILS 0 TILS 0 TILS STRUTURL S00 NRL NOTS N RVITIONS S00 NRL NOTS N RVITIONS S PIR IMNSION PLN - R S PIR IMNSION PLN - R S OUNTION PLN - R S OUNTION PLN - R S SON LOOR RMIN PLN - R S ROO RMIN PLN - R S ROO RMIN PLN - R S0 TYPIL ONRT TILS S0 ONRT TILS S0 ONRT TILS S0 TYPIL STL TILS S0 TYPIL STL TILS S0 TYPIL STL TILS S TYPIL STL LOOR RMIN TILS S TYPIL STL ROO RMIN TILS S TYPIL STL TILS S LTRL R RM LVTIONS S LTRL R TILS RITTURL MOLITION OVRLL OMPOSIT IRST LVL RITTURL MOLITION PLN MOLITION PLN - R '' MOLITION PLN - R '' MOLITION PLN - R '' MOLITION PLN - R '' SON LVL RITTURL 00 RVITIONS, ONVNTIONS & SYMOLS 00 WLL TYPS 00 TYPIL XTRIOR WLL TILS 00 TYPIL INTRIOR TILS OVRLL OMPOSIT LOOR PLN LOOR PLN - R '' IRST LVL LSSROOM ITION LOOR PLN - R '' TRI ITION LOOR PLN - R '' LK OX RNOVTION LOOR PLN - R '' SON LVL LSSROOM ITION LRSTORY PLN - R '' TRI ROO PLN_LSSROOM ROO PLN_TRI 0 XTRIOR LVTIONS 0 XTRIOR LVTIONS UILIN STIONS UILIN STIONS 0 WLL STIONS & TILS 0 WLL STIONS & TILS 0 WLL STIONS & TILS 0 WLL STIONS & TILS 0 WLL STIONS & TILS 0 WLL STIONS & TILS 0 STION TILS 0 ROO TILS 0 ROO TILS 0 NLR TOILT ROOMS NLR STIR PLNS STIR PLN & TILS STIR TILS NLR RMP & STIR PLN TILS PLN TILS 0 OOR SULS 0 OOR RM TYPS 0 OOR/WINOW RM TYPS 0 OOR SUL - LT I, JM, N SILL TILS OVRLL OMPOSIT RLT ILIN PLN - IRST LVL RLT ILIN PLN - R '' IRST LVL LSSROOM RLT ILIN PLN - R '' TRI RLT ILIN PLN R '' SON LVL LSSROOM URNISINS & QUIPMNT PLN - R '' IRST LVL LSSROOM URNISINS & QUIPMNT PLN - R '' TRI URNISINS & QUIPMNT PLN - R '' SON LVL LSSROOM 0 OLOR SUL 0 ROOM INIS SULS SWORK LVTIONS INTRIOR LVTIONS INTRIOR LVTIONS INTRIOR LVTIONS INTRIOR LVTIONS INIS LOOR PLN - R '' IRST & SON LVL LSSROOM ITION LOOR INIS PLN - R '' TRI ITION MNIL M MNIL SYMOLS LN M0 LVL MNIL PLN - TRI M0 LVL MNIL MO PLN - LSSROOM M0 LVL MNIL PLN - LSSROOM M0 LVL MNIL PLN - STIRS M LVL MNIL MO PLN - LSSROOM M LVL MNIL PLN - LSSROOM M MNIL ROO PLN - TRI M MNIL ROO PLN - LSSROOM M0 NLR MNIL ROOM PLN M0 MNIL SULS M0 MNIL TILS M0 ONTROL IRMS N SQUNS M0 ONTROL IRMS N SQUNS M0 ONTROL IRMS N SQUNS LTRIL LTRIL SYMOLS LN L0 LVL LITIN PLN - TRI L0 LVL LITIN PLN - LSSROOM L LVL LITIN PLN - LSSROOM P0 LVL POWR PLN - TRI P0 LVL POWR PLN - LSSROOM P0 LVL POWR PLN - STIRS P LVL POWR PLN - LSSROOM P LTRIL ROO PLN - TRI P LTRIL ROO PLN - LSSROOM 0 PRTIL LTRIL ON LIN IRM 0 LTRIL SULS 0 LTRIL PNLOR SULS 0 LTRIL TILS PLUMIN P0 LVL PLUMIN PLN - TRI P0 LVL PLUMIN PLN - LSSROOM P LVL PLUMIN PLN - TRI P LVL PLUMIN PLN - LSSROOM P PLUMIN ROO PLN - TRI P PLUMIN ROO PLN - LSSROOM P0 PLUMIN SULS P0 PLUMIN TILS P0 PLUMIN RISR IRMS IR LRM IR LRM/INTROM NOTS N LNS 0 LVL IR LRM PLN - TRI 0 LVL IR LRM PLN - LSSROOM LVL IR LRM PLN - LSSROOM TNOLOY T TNOLOY NOTS N LNS T LVL OVRLL PLN T LVL OVRLL PLN T0 LVL TNOLOY PLN - TRI T0 LVL TNOLOY PLN - LSSROOM T LVL TNOLOY PLN - LSSROOM T0 TNOLOY I RISR TIL 0 ST RNWY PLZ SUIT 00 OUSTON, TXS 0 P ONSULTNTS: IVIL: SSNR NINRIN STRUTURL: STNT MP: R NINRS inal Plans for Pemit and idding JMS RL RUR I SOOL ITIONS N RNOVTIONS RYN, TXS RWN: uthor K: SL: hecker ISSU: March, 0 ST TITL: RWIN INX //0 :0: PM

3 //0 :0: PM I ONY TYP : - ONSTRUTION TYP: II- MX LLOWL R:,00 S TUL R:, S UILIN -II LSSROOM ITION III V,,, YS SONRY ONY(S 0, 0): UTOMTI IR SPRSSION: SSMLY RO - / - / -, SSMLY USINSS RO (MIN. RS) (SOWN ON PLN) II - / II- USR RO LSS:, UTIONL PRIMRY ONY (S. 0.): XISTIN UILIN: I 00 RS SRV:,0 S LSSROOM ITION TO XISTIN UILIN - III (SON LOOR).T.. SOP ITION TO XISTIN UILIN - V (IRST LOOR) LSSROOM ITION TO XISTIN UILIN - III (IRST LOOR) LOOR R SUMMRY:,000 S,0 S STORY & STORY UILIN IT: TRI ITION TWN XISTIN UILINS - IV & VII (IRST LOOR),0 S RYN INPNNT SOOL ISTRIT, RYN, TXS JMS RL RUR I SOOL - ITIONS N RNOVTIONS LOTION: PROJT: VI ONY TYP : - ONSTRUTION TYP: II- MX LLOWL R:,00 S TUL R:, S UILIN -VI PROJT NRL INO: TUL UILIN R (S) VII " = 0'-0" N IV ONY TYP : ONSTRUTION TYP: II- MX LLOWL R:,00 S TUL R: 0,0 S UILIN -IV ONY TYP : ONSTRUTION TYP: II- MX LLOWL R:, S TUL R:, S UILIN -V TYP O ONSTRUTION: (T 0) O RVIW_OVRLL ONY TYP : - ONSTRUTION TYP: II- MX LLOWL R:,00 S TUL R:, S XISTIN UILIN O RVIW & NW ITIONS TO XISTIN UILINS TRI ITION UILIN -VII ONY TYP : ONSTRUTION TYP: II- MX LLOWL R:,000 S TUL R:, S ONY TYP : - ONSTRUTION TYP: II- MX LLOWL R:,00 S TUL R:, S UILIN -III II UILIN -I March, O RVIW PLN ST TITL: ISSU: s indicated hecker K: SL: uthor RWN: JMS RL RUR I SOOL ITIONS N RNOVTIONS RYN, TXS inal Plans for Pemit and idding MP: R NINRS STRUTURL: STNT IVIL: SSNR NINRIN ONSULTNTS: P ST RNWY PLZ SUIT 00 OUSTON, TXS 0

4 XISTIN -R RT R SPRTION WLL TO ROO K - TO RMIN XISTIN -R RT WLL TO ROO K OR RT ILIN SSMLY T XIT STIRWY - TO RMIN XISTIN -R RT R SPRTION WLL TO ROO K - TO RMIN XISTIN -R RT R SPRTION WLL TO ROO K - TO RMIN XISTIN -R RT WLL TO ROO K OR RT ILIN SSMLY T XIT STIRWY - TO RMIN XISTIN -R RT R SPRTION WLL TO ROO K - TO RMIN OYS IRLS LX SP NW -R RT WLL TO ROO K N -R RT ROO/ILIN SSMLY TO ONTINU XSISTIN -R RT STIR NLOSUR M / PUMP LSSROOM I JN L NW -R RT WLL TO ROO K N -R RT ROO/ILIN SSMLY TO ONTINU XSISTIN -R RT STIR NLOSUR SIN L 0 LSSROOM 0 LSSROOM LSSROOM LL WLLS ROUN SIN N PRP ROOMS SLL NON - RT WLLS TO K - LL WLLS ROUN M STOR ROOM 0 SLL -R RT WLL TO K PRP ROOM 0 LSSROOM 0 LSSROOM LSSROOM SIN L 0 LSSROOM 0 NW -R RT WLL TO K T STIR NLOSUR - XIT STIR IS PRT O RQUIR MNS O RSS LSSROOM LSSROOM RSS: RSS ORRIOR NOT RQUIR TO IR RT PR TL. (SPRINKLR SYSTM PROVI) TOTL ONT LO = NUMR O XITS RQUIR = (TL.) NUMR O XITS PROVI = RSS WIT RQUIR = ( X 0.) = " RSS ORRIOR WIT PROVI = " TOTL RSS PITY = 0 NW -R RT WLL TO K T STIR NLOSUR - XIT STIR IS PRT O RQUIR MNS O RSS 0 LSSROOM 0 RSS STIRS: RSS ORRIOR NOT RQUIR TO IR RT PR TL. OT STIRS R PRT O T RQUIR MNS O RSS IR RT NLOSUR NOT RQUIR (S PR S 0., XPTION-. & S 0, XPTION-): STIR OS NOT ONNT MOR TN TWO STORIS IN SPRINLR UILIN. TOTL ONT LO = 0 NUMR O XITS RQUIR = (TL.) NUMR O XITS PROVI = XIT WIT RQUIR (0 X 0.) = " XIT WIT PROVI = " TOTL RSS PITY = 0 O RVIW_LSSROOM_L : O RVIW_LSSROOM_L /" = '-0" NW LSSROOM ITION O RVIW: I 00 PRIMRY ONY (S. 0.): USR RO LSS:, UTIONL SONRY ONY(S 0, 0): NON TYP O ONSTRUTION: (T 0) UTOMTI IR SPRSSION: UILIN R N IT LIMITTIONS (T 0) XISTIN UILIN -III (TYP II-) NW ITION (TYP II-) XISTIN UILIN -III YS NW ITION YS ONY TYP: / L TYP II LLOWL R:,00 / LLOWL T: -STORY (') R MOIITION: RONT INRS % SPRINKLR INRS % ONY / RSS LN: INTRIOR N XTRIOR OOR RSS (I STION 0.) PIR '-0" OOR (." LR) T."/ONT = ONTS PIR '-0" OOR (0.0" LR) T."/ONT = 0 ONTS TOTL LLOWL R WIT INRSS: (,00 +,0 +,000) =, S. TUL R: XISTIN UILIN STION-III ,00 S NW ITION TO UILIN STION-III ,000 S IRPROOIN RQUIRMNTS: STRUTURL RM: (TL 0) XTRIOR RIN WLLS: (TL 0) INTRIOR RIN WLLS: (TL 0) XTRIOR NON-RIN WLLS: (TL 0) INTRIOR NON RIN WLLS: (TL 0) LOOR ONSTRUTION N MS SPORTIN LOORS (TL 0): ROO ONSTRUTION N MS N JOIST SPORTIN ROOS: TOTL R ,00 S < LLOWL R (, S) NO IR RT R SPRTION WLL RQUIR TWN XISTIN UILIN N NW ITION IR SPRTIONS: R. ( R. WN SPORTIN ROO ONLY, T. 0 (b) R. R. 0 R. (LL MOR TN 0 T ROM PROPRTY LIN) 0 R. R. R. (0 R. WR VRY PRT O ROO ONSTRUTION IS 0 T OR MOR OV NY LOOR IMMITLY LOW, T. 0 (c) XISTIN PIR '-0" OOR (." LR) T."/ONT = ONTS SINL '-0" OOR (." LR) T."/ONT = ONTS LSS ROOM (SOPS & LS) PT O TRVL TO N XIT RSS RQUIRMNTS: I 00. ONY LOS: UNTION O SP: SQ. T PR ONT: LSSROOMS 0 ROSS SSORY STOR RS, M. QUIPMNT ROOMS 00 ROSS USINSS RS 0 ROSS XRIS ROOMS 0 ROSS. RQUIR RSS WIT: (TL 0..) 0 ROSS SSMLY WITOUT IX STS ROSS WLL TO K RTIN LN R R IR RRIR TO K (0 MIN RS) - NM-TK - IR RSISTN (00) T MU ONSTRUTION R WLL TO K (0 MIN OORS OR MIN OORS - RR TO SUL) - UL No U T STU ONSTRUTION - NM-TK - IR RSISTN (00) T MU ONSTRUTION NON - RT WLL TO K - RR /00 OR MOR INORMTION RNOVT R XISTIN R - NO WORK NW ITION ST NLOSURS OR LVTOR (S 0.): R. (ST NLOSURS SLL V IR RSISTIV RTIN NOT LSS TN T LOOR SSMLY PNTRT N SLL NOT LSS TN R. WR ONNTIN LSS TN STORIS) ST NLOSURS OR STIRS (S 0. XPTION.): 0 R. (ST NLOSUR IS NOT RQUIR OR LOOR OPNINS TT O NOT ONNT MOR TN TWO STORIS) VRTIL XIT NLUSURS (S 0 XPTION - ): NOT RQUIR TO NLOS WN INTRIOR STIRWY SRVS ONLY IRST & SON STORY O SPRINKLR UILIN; N MNS O RSS PROVI ROM OT LOORS) ORRIORS (TL.): 0 R. - WR IR SPRINKLR SYSTM IS PROVI MINIMUM STIR / ORRIOR WIT (TL 0.) RSS WIT PR ONT (TL 0.) 0. NUMR O XITS RQUIR (TL ) - ONTS -00 ONTS 0-00 ONTS 0 OR MOR ONTS " MIN UL SSMLY NOTS: -R RT LOOR & STRUTRUL RM SPORTIN R ROO/ILIN SSMLY ONY SPRTIONS: NOT RQUIR - SINL ONY MXIMUM TRVL ISTN TO N XIT - "" ONY (T.) 0' (WIT SPRINLR SYSTM). -R RT OLUMNS UL# X0 ININTL US SPRTIONS (TL 0.): LORTORIS/VOTIONL SOPS OILR N URN ROOMS 0 R. - WR IR SPRINKLR SYSTM IS PROVI STOR N LUNRY ROOMS 0 R. - WR IR SPRINKLR SYSTM IS PROVI PINT SOPS, (NOT LSSII S RO-) R. - WR IR SPRINKLR SYSTM IS PROVI 0 R. - WR IR SPRINKLR SYSTM IS PROVI MXIMUM LNT O N ORRIORS (..) XITS TROU JOININ ROOMS (.) 0' OR UNLIMT LNT WN MIN. WIT =. TIMS T WIT O T N ORRIOR. 0' OR SPRINKLR. PRMITT T SSORY, NON-I-ZR ROOMS W/ RNL PT O TRVL PROVI; NOT PRMITT TROU KITNS, STOR, OR SIMILR OMMON PT O TRVL (.) < 0 O SRV = '-0" TO OI O XIT PTS. -R RT LOOR SSMLY UL# N0. -R RT ROO SSMLY UL# X0. -R RT WLL SSMLY UL# U. -R RT ROO SSMLY UL# U RR ST OR UL SSMLY TILS 0 ST RNWY PLZ SUIT 00 OUSTON, TXS 0 P ONSULTNTS: IVIL: SSNR NINRIN STRUTURL: STNT MP: R NINRS inal Plans for Pemit and idding JMS RL RUR I SOOL ITIONS N RNOVTIONS RYN, TXS RWN: uthor K: SL: hecker s indicated ISSU: March, 0 ST TITL: O RVIW - LSSROOM.000. //0 :0: PM

5 NW TRI ITION O RVIW: I 00 PRIMRY ONY (S. 0.): USR RO LSS: -, SSMLY / TRI SONRY ONY(S 0, 0): TYP O ONSTRUTION: (T 0) UTOMTI IR SPRSSION: UILIN R N IT LIMITTIONS (T 0) - (KITN) XISTIN UILIN -VII (TYP II-) NW ITION (TYP II-) XISTIN UILIN -VII YS NW ITION YS RNOVT STIR TO MINTIN SM RSS WIT S XISTIN STIR -R RT R SPRTION WLL TO ROO K S PR S 0. & TL 0. ONY TYP: - / L TYP II LLOWL R:,00 / -STORY (') R MOIITION: RONT INRS % SPRINKLR INRS % TOTL LLOWL R WIT INRSS: (,00 +,0 +,00) =,0 S. TUL R: XISTIN UILIN STION-VII , S NW ITION TO UILIN STION-III , S TOTL R , S < LLOWL R (,0 S) IR RT R SPRTION WLL: NW ITION ONNTS XISTIN UILIN STION-VII & XISTIN UILIN STION-IV -R IR SPRTION WLL RQUIR TWN XISTIN UILIN & NW ITION - S PLN IRPROOIN RQUIRMNTS: STRUTURL RM: (TL 0) 0 R. XTRIOR RIN WLLS: (TL 0) 0 R. INTRIOR RIN WLLS: (TL 0) 0 R. XTRIOR NON-RIN WLLS: (TL 0) 0 R. (LL MOR TN 0 T ROM PROPRTY LIN) INTRIOR NON RIN WLLS: (TL 0) 0 R. LOOR ONSTRUTION N MS SPORTIN LOORS (TL 0): 0 R. ROO ONSTRUTION N MS N JOIST SPORTIN ROOS: 0 R. IR SPRTIONS: ST NLOSURS OR LVTOR (S 0.): R. (ST NLOSURS SLL V IR RSISTIV RTIN NOT LSS TN T LOOR SSMLY PNTRT N SLL NOT LSS TN R. WR ONNTIN LSS TN STORIS) ST NLOSURS OR STIRS (S 0. XPTION.): 0 R. (ST NLOSUR IS NOT RQUIR OR LOOR OPNINS TT O NOT ONNT MOR TN TWO STORIS) VRTIL XIT NLUSURS (S 0 XPTION - ): NOT RQUIR TO NLOS WN INTRIOR STIRWY SRVS ONLY IRST & SON STORY O SPRINKLR UILIN; N MNS O RSS PROVI ROM OT LOORS) ORRIORS (TL.): 0 R. - WR IR SPRINKLR SYSTM IS PROVI ONY SPRTIONS: NOT RQUIR - SINL ONY ININTL US SPRTIONS (TL 0.): LORTORIS/VOTIONL SOPS 0 R. - WR IR SPRINKLR SYSTM IS PROVI PINT SOPS, (NOT LSSII S RO-) R. - WR IR SPRINKLR SYSTM IS PROVI ORIZONTL ONTINUITY: IR WLL NOT RQUIR TO XTN '-" YON XTRIOR SUR, WN UILINS ON OT SIS O IR WLL R PROTT WIT UTOMTI SPRINKLR SYSTM (S-0., xception-) VRTIL ONTINUITY: -R IR WLL SLL PRMITT TO TRMINT T T UNRSI O NONOMUSTIL ROO K WIT LSS- ROO OVRIN WR OPNINS IN T ROO R NOT LOT WITIN '-0" O IR WLL (S-0., xception-) RSS OORS PROVI IN -R RT R SPRTION WLL - TO MINTIN XISTIN PT O RSS OILR N URN ROOMS 0 R. - WR IR SPRINKLR SYSTM IS PROVI STOR N LUNRY ROOMS 0 R. - WR IR SPRINKLR SYSTM IS PROVI NW TRI ITION TO UILIN -VII ONY TYP : - ONSTRUTION TYP: II- MX LLOWL R:,0 S TUL R:, S RSS: XISTIN TRI ONT LO = NW ITION ONT LO = TOTL ONT LO = 0 NUMR O XITS RQUIR = (TL.) NUMR O XITS PROVI = RSS WIT RQUIR = (0 X 0.) = " RSS WIT PROVI = " TOTL RSS PITY = XISTIN XITS TO RMIN N ONY / RSS LN: INTRIOR N XTRIOR OOR RSS (I STION 0.) NO IR SPRTION RQUIR TWN TRI STIN N OMMRIL KITN S PR TL 0.. (NOT-"e") PIR '-0" OOR (." LR) T."/ONT = ONTS PIR '-0" OOR (0.0" LR) T."/ONT = 0 ONTS XISTIN PIR '-0" OOR (." LR) T."/ONT = ONTS WLL TO K RTIN LN SINL '-0" OOR (." LR) T."/ONT = ONTS R R IR RRIR TO K (0 MIN RS) - NM-TK - IR RSISTN (00) T MU ONSTRUTION PT O TRVL TO N XIT RSS RQUIRMNTS: I 00. ONY LOS: (TL 0..) R WLL TO K (0 MIN OORS OR MIN OORS - RR TO SUL) - UL No U T STU ONSTRUTION - NM-TK - IR RSISTN (00) T MU ONSTRUTION NON - RT WLL TO K - RR /00 OR MOR INORMTION UNTION O SP: SQ. T PR ONT: LSSROOMS 0 ROSS RNOVT R LSS ROOM (SOPS & LS) 0 ROSS SSORY STOR RS, M. QUIPMNT ROOMS 00 ROSS USINSS RS 0 ROSS XISTIN R - NO WORK XRIS ROOMS 0 ROSS SSMLY WITOUT IX STS ROSS. RQUIR RSS WIT: NW ITION MINIMUM STIR / ORRIOR WIT (TL 0.) RSS WIT PR ONT (TL 0.) 0. NUMR O XITS RQUIR (TL ) " MIN -R RT LOOR & STRUTRUL RM SPORTIN R ROO/ILIN SSMLY - ONTS -00 ONTS 0-00 ONTS 0 OR MOR ONTS MXIMUM TRVL ISTN TO N XIT - "" ONY (T.) 0' (WIT SPRINLR SYSTM) MXIMUM LNT O N ORRIORS (..) XITS TROU JOININ ROOMS (.) 0' OR UNLIMT LNT WN MIN. WIT =. TIMS T WIT O T N ORRIOR. 0' OR SPRINKLR. PRMITT T SSORY, NON-I-ZR ROOMS W/ RNL PT O TRVL PROVI; NOT PRMITT TROU KITNS, STOR, OR SIMILR OMMON PT O TRVL (.) < 0 O SRV = '-0" TO OI O XIT PTS UL SSMLY NOTS:. -R RT OLUMNS UL# X0. -R RT LOOR SSMLY UL# N0. -R RT ROO SSMLY UL# X0. -R RT WLL SSMLY UL# U. -R RT ROO SSMLY UL# U RR ST OR UL SSMLY TILS O RVIW_TRI : RRN ON / 0 ST RNWY PLZ SUIT 00 OUSTON, TXS 0 P ONSULTNTS: IVIL: SSNR NINRIN STRUTURL: STNT MP: R NINRS inal Plans for Pemit and idding JMS RL RUR I SOOL ITIONS N RNOVTIONS RYN, TXS RWN: uthor K: SL: hecker s indicated ISSU: March, 0 ST TITL: O RVIW - TRI.000. //0 :0: PM

6 U. loor and eiling Runners (Not shown) hannel shaped runners, -/ in. deep (min), -/ in. legs, formed from min No. MS galv steel, attached to floor and ceiling with fasteners spaced in. O max.. raming Members* loor and eiling Runners (Not shown) s an alternate to Item - hannel shaped, min -/ in. deep, attached to floor and ceiling with fasteners in. O. max. LLSTL & YPSUM PROUTS IN Type SRM raming System ONSOLIT RITORS ORP, UILIN PROUTS IV Type SRM raming System QUIL RUN UILIN MTRILS IN Type SRM raming System SO STL STU MNUTURIN O Type SRM raming System STL ONSTRUTION SYSTMS IN Type SRM raming System UNIT MTL PROUTS IN Type SRM raming System. raming Members* - loor and eiling Runners Not shown - In lieu of Item or use with Item, proprietary channel shaped runners, -/ in. wide by min -/ in. deep fabricated from min 0.00 in. thick galv steel, attached to floor and ceiling with fasteners spaced in. O max. LIORNI XPN MTL PROUTS O Viper0 Track RO M IN SmartTrack0 MRINO/WR, IV O WR INUSTRIS IN Viper0 Track PILLIPS M O L L Viper0 Track. loor and eiling Runners (Not shown) or use with Item - hannel shaped, fabricated from min 0 MS corrosion-protected or galv steel, min depth to accommodate stud size, with min in. long legs, attached to floor and ceiling with fasteners spaced max in. O.. raming Members* loor and eiling Runners Not shown - In lieu of Items through or use with Item and only, proprietary channel shaped runners, -/ in. deep by min -/ in. wide fabricated from min 0.0 in. thick galv steel, attached to floor and ceiling with fasteners spaced in. O max. LRKITRI UILIN SYSTMS ProTRK MWS L L ProTRK M MTL RMIN ProTRK RM SLS L L Ram ProTRK STL STRUTURL PROUTS L L Tri-S ProTRK. raming Members* loor and eiling Runners Not shown - In lieu of Items through or use with Item and I only, proprietary channel shaped runners, -/ in. deep by min -/ in. wide fabricated from min 0.0 in. thick galv steel, attached to floor and ceiling with fasteners spaced in. O max. TLLIN INUSTRIS L L TRU-TRK. raming Members* loor and eiling Runners Not shown - In lieu of Items through or use with Item, channel shaped runners, -/ in. deep by min -/ in. wide fabricated from min MS steel, attached to floor and ceiling with fasteners spaced in. O max. KIRII (ON KON) LT Type KIRII. raming Members* loor and eiling Runners Not shown - In lieu of Items through or use with Item, channel shaped runners, -/ in. deep by min -/ in. wide, attached to floor and ceiling with fasteners spaced in. O max. STUO UILIN SYSTMS ROSTU Track. loor and eiling Runners (Not shown) hannel shaped, fabricated from min 0.0 in. galv steel, min width to accommodate stud size, with min in. long legs, for use with studs specified below and fabricated from min 0.0 in. galv steel or thicker, attached to floor and ceiling with fasteners spaced max in. O. MRINO/WR, IV O WR INUSTRIS IN Viper0 Track VT0. I. raming Members* - loor and eiling Runners Not shown - In lieu of Item or use with Item, proprietary channel shaped runners, -/ in. wide by min -/ in. deep fabricated from min 0.00 in. thick galv steel, attached to floor and ceiling with fasteners spaced in. O max. TLLIN INUSTRIS L L Viper0 Track J. raming Members* loor and eiling Runners (Not Shown) s an alternate to Item - or use with Item L. hannel shaped, attached to floor and ceiling with fasteners in. O. max. ILY MTL PROUTS LT Type PLTINUM PLUS. Steel Studs hannel shaped, -/ in. deep (min), formed from min No. MS galv steel spaced in. O max. Studs to be cut / in. less than assembly height.. raming Members* Steel Studs s an alternate to Item - hannel shaped studs, min -/ in. deep, spaced a max of in. O. Studs to be cut / in. less than assembly height. LLSTL & YPSUM PROUTS IN Type SRM raming System ONSOLIT RITORS ORP, UILIN PROUTS IV Type SRM raming System QUIL RUN UILIN MTRILS IN Type SRM raming System SO STL STU MNUTURIN O Type SRM raming System STL ONSTRUTION SYSTMS IN Type SRM raming System UNIT MTL PROUTS IN Type SRM raming System. raming Members* - Steel Studs Not shown - In lieu of Item or use with Item, proprietary channel shaped steel studs, -/ in. wide by min -/ in. deep fabricated from min 0.00 in. thick galv steel. Studs cut / in. less in length than assembly height. LIORNI XPN MTL PROUTS O Viper0 RO M IN SmartStud0 MRINO/WR, IV O WR INUSTRIS IN Viper0 PILLIPS M O L L Viper0. Steel Studs (s an alternate to Item, or use with Item ) hannel shaped, fabricated from min 0 MS corrosion-protected or galv steel, -/ in. min depth, spaced a max of in. O. Studs friction-fit into floor and ceiling runners. Studs to be cut / to / in. less than assembly height.. raming Members* Steel Studs s an alternate to Items through - or use with Item and only, channel shaped studs, min -/ in. wide fabricated from min 0.0 in. thick galv steel, spaced a max of in. O. Studs to be cut / in. less than assembly height. LRKITRI UILIN SYSTMS ProSTU MWS L L ProSTU M MTL RMIN ProSTU RM SLS L L Ram ProSTU STL STRUTURL PROUTS L L Tri-S ProSTU. raming Members* Steel Studs s an alternate to Items through - or use with Item and I only, channel shaped studs, min -/ in. wide fabricated from min 0.0 in. thick galv steel, spaced a max of in. O. Studs to be cut / in. less than assembly height. TLLIN INUSTRIS L L TRU-STU. raming Members* Steel Studs s an alternate to Items through - or use with Item, channel shaped studs, min -/ in. wide fabricated from min MS steel, spaced a max of in. O. Studs to be cut / in. less than assembly height. KIRII (ON KON) LT Type KIRII. raming Members* - Steel Studs Not shown - In lieu of Item through - or use with Item. Proprietary channel shaped studs, minimum -/ in. wide, Studs to be cut / in. less than the assembly height. STUO UILIN SYSTMS ROSTU. raming Members* - Steel Studs Not shown - In lieu of Item or use with Item I, proprietary channel shaped steel studs, -/ in. wide by min -/ in. deep fabricated from min 0.00 in. thick galv steel. Studs cut / in. less in length than assembly height. TLLIN INUSTRIS L L Viper0 I. raming Members* Steel Studs In lieu of Item - or use with Item, channel shaped studs, fabricated from min MS corrosionprotected steel, -/ in. deep (min), spaced in. O max. Studs to be cut / in. less than assembly height. MéTL IN Stud corrosion protected steel, -/ in. deep (min), spaced in. O max. Studs to be cut / in. less than assembly height. OLMR SPLY IN PRIMSTU K. raming Members* - Steel Studs s an alternate to Item - or use with Item (-/ in. wide track), channel shaped studs, fabricated from min MS corrosion-protected steel, -/ in. wide by -/ in. deep, spaced a max of in. O. Studs to be cut / to / in. less than assembly height. MRINO/WR, IV O WR INUSTRIS IN StudRite L. raming Members* Steel Studs s an alternate to Item - or use with Item J, channel shaped, min -/ in. wide, spaced a max of in. O. Studs to be cut / to / in. less than assembly height. ILY MTL PROUTS LT Type PLTINUM PLUS. atts and lankets* (Optional) Mineral wool or glass fiber batts partially or completely filling stud cavity. See atts and lankets (ZJZ) category for names of lassified companies.. iber, Sprayed* s an alternate to atts and lankets (Item ) (0% orate ormulation) Spray applied cellulose material. The fiber is applied with water to completely fill the enclosed cavity in accordance with the application instructions supplied with the product with a nominal dry density of. lb/ft. lternate pplication Method: The fiber is applied without water or adhesive at a nominal dry density of. lb/ft, in accordance with the application instructions supplied with the product. U S RNIR L L INS& INS for use with wet or dry application. INSL and INS0L are to be used for dry application only.. iber, Sprayed* s an alternate to atts and lankets (Item ) and Item - Spray applied cellulose insulation material. The fiber is applied with water to interior surfaces in accordance with the application instructions supplied with the product. pplied to completely fill the enclosed cavity. Minimum dry density of. pounds per cubic ft. NU-WOOL O IN ellulose Insulation. iber, Sprayed* s an alternate to atts and lankets (Item ) - Spray applied cellulose fiber. The fiber is applied with water to completely fill the enclosed cavity in accordance with the application instructions supplied with the product. The minimum dry density shall be.0 lbs/ft. INTRNTIONL LLULOS ORP elbar-rl. atts and lankets* or use with Item. Nom in. thick, minimum. pcf mineral wool batts, friction fit between the studs and floor and ceiling runners. See atts and lankets (ZJZ) category for names of manufacturers. esign No. U October, 0 Nonbearing Wall Rating R.. atts and lankets* or use with Item P. Placed in stud cavities, any min. -/ in. thick glass fiber insulation bearing the UL lassification Marking as to Surface urning haracteristics and/or ire Resistance. See atts and lankets (KNV or ZJZ) ategories for names of lassified companies.. ypsum oard* / in. thick, ft wide, attached to steel studs and floor and ceiling track with in. long, Type S steel screws spaced in. O. along edges of board and in. O in the field of the board. Joints oriented vertically and staggered on opposite sides of the assembly. When attached to item (resilient channels) or, or (furring channels), gypsum board is screw attached to furring channels with in. long, Type S steel screws spaced in. O. I RYWLL SPLIS LT Type X, / Type X, Type lueglass xterior Sheathing MRIN YPSUM O Types -, X-, M-lass IJIN NW UILIN MTRILS PULI LT O Type X-. IN Types R,, IP-R, IP-X, IP-X, IP-R, SX, SX, USX, WR or WRX (Joint tape and compound, Item, optional for use with Type USX). RTINT YPSUM IN Types, R, lasroc, Type X, Type X-, Type, SilentX, /" asi-lite Type X. ONTINNTL UILIN PROUTS OPRTIN O, L L Types L, L, L-/, L-W, LLLX. ORI-PII YPSUM L L Types,,,, P,,, P,, S, PS, LS,, Type X, Veneer Plaster ase - Type X, Water Rated - Type X, Sheathing - Type X, Soffit - Type X, T-, reenlass Type X, Type X omfortuard Sound eadening ypsum oard, Type LWX, Veneer Plaster ase-type LWX, Water Rated-Type LWX, Sheathing Type- LWX, Soffit-Type LWX, Type LW, Water Rated-Type LW, Sheathing Type- LW, Soffit-Type LW, Type LWX, Veneer Plaster ase - Type LWX, Water Rated - Type LWX, Sheathing - Type LWX, Soffit - Type LWX, Type LW, Water Rated - Type LW, Sheathing - Type LW. NTIONL YPSUM O Types exp-, SK, SK-, SK-, SMR-, SW-, SW-, SW, SW-, SW-, SW-, SW-, SL. PO UILIN PROUTS L L, PO YPSUM Types P-, P-, P-, PS-WRS. PNL RY S Types RX, PRX, RX, MX, TX. SIM YPSUM INUSTRY (SRURI) O LT Type X- TI YPSUM PROUTS PL Type X, Type. UNIT STTS YPSUM O Type R,, RX-, IP-R, IP-X, IP-X, IP- R, SX, SX, WR, WRX, USX (Joint tape and compound, Item, optional for use with Type USX). US ORL ZWWI RYWLL L L SZ Types, SX US MXIO S V Type R,, IP-R, IP-X, IP-X, IP-R, SX, SX, USX, WR or WRX (Joint tape and compound, Item, optional for use with Type USX).. ypsum oard* (s alternate to Item ) - Nom / in. thick gypsum panels with beveled, square or tapered edges, applied vertically or horizontally. Vertical joints centered over studs and staggered one stud cavity on opposite sides of studs. orizontal edge joints and horizontal butt joints on opposite sides of studs need not be staggered or backed by steel framing. Panels attached to steel studs and floor runner with in. long Type S steel screws spaced in. O when applied horizontally, or in. O along vertical and bottom edges and in. O in the field when panels are applied vertically. When used in widths other than in., gypsum panels to be installed horizontally. RTINT YPSUM IN Type X, Type X-, Type, Type R/ lasroc. IN Types R,, IP-R, IP-X, IP-X, IP-R, SX, SX, USX, WR or WRX (Joint tape and compound, Item, optional for use with Type USX). ONTINNTL UILIN PROUTS OPRTIN O, L L Type L, L-/ ORI-PII YPSUM L L Types P, P,, S. TI YPSUM PROUTS PL Type X, Type. UNIT STTS YPSUM O Types R,, RX-, IP-R, IP-X, IP-X, IP- R, SX, SX, WR, WRX, USX (Joint tape and compound, Item, optional for use with Type USX). US ORL ZWWI RYWLL L L SZ Types, SX US MXIO S V Type R,, IP-R, IP-X, IP-X, IP-R, SX, SX, USX, WR or WRX (Joint tape and compound, Item, optional for use with Type USX).. ypsum oard* (s an alternate to Items or ) Nom / in. thick, ft wide, installed as described in Item with screw length increased to -/ in. IN Types R, IP-R. UNIT STTS YPSUM O Types R, IP-R. US MXIO S V Types R, IP-R.. ypsum oard* s an alternate to Items,, and - Nom. / in. thick gypsum panels, with square edges, applied horizontally. ypsum panels fastened to framing with in. long bugle head steel screws spaced a max in. O, with last screws / in. and in. from each edge of board. orizontal joints need not be backed by steel framing. orizontal edge joints and horizontal butt joints on opposite sides of studs on interior walls need not be staggered or backed by steel framing. ORI-PII YPSUM L L Type, reenlass Type X.. ypsum oard* s an alternate to Items,,, and - Nom. / in. thick gypsum panels applied vertically or horizontally. orizontal edge joints and horizontal butt joints on opposite sides of studs need not be staggered or backed by steel framing. ypsum panels fastened to framing with in. long Type S steel screws in. O along vertical edges and in. O in the field when panels are applied vertically. When gypsum panels applied horizontally, fasten to framing with in. long Type S steel screws spaced in. O along vertical edges and in the field. Screws spaced a max in. along the top and bottom edges of the wall for both vertical and horizontal applications. NTIONL YPSUM O Types exp-, SK, SK-, SK-, SL, SW-, SW-, SW, SW-, SW-, SW-, SW-, SMR-.. ypsum oard* (s an alternate to Items through ) - Installed as described in Item. / in. thick, ft. wide, paper surfaced, applied vertically only and fastened to the studs and plates with in. long, Type S steel screws spaced, in. O. Not to be used with item. NTIONL YPSUM O Soundreak XP Type X ypsum oard. ypsum oard* (Not Shown) - (s an alternate to Item when used as the base layer on one or both sides of wall. or direct attachment only to steel studs Item ) - Nom / in. thick lead backed gypsum panels with beveled, square or tapered edges, applied vertically. Vertical joints centered over studs and staggered min stud cavity on opposite sides of studs. ypsum board secured to studs with -/ in. long Type S- steel screws spaced in. O at perimeter and in. O in the field. RY-R NINRIN ORP Type R-L. ypsum oard* (s an alternate to Items through ) or use with Items and only, / in. thick, ft wide, attached to steel studs and floor and ceiling track with in. long, Type S steel screws spaced in. O. along edges of board and in. O in the field of the board. Joints oriented vertically and staggered on opposite sides of the assembly. ONTINNTL UILIN PROUTS OPRTIN O, L L Type L, L-/ NTIONL YPSUM O Types SW UNIT STTS YPSUM O Type SX US ORL ZWWI RYWLL L L SZ Type SX. ypsum oard* (s an alternate to Items through ) Nominal / in. thick, ft wide panels, applied vertically and secured as described in Item. PO UILIN PROUTS L L, PO YPSUM Type QuietRock S. I. ypsum oard* (s an alternate to Items through ) or use with Items and only, / in. thick, ft wide, attached to steel studs and floor and ceiling track with in. long, Type S steel screws spaced in. O. along edges of board and in. O in the field of the board. Joints oriented vertically and staggered on opposite sides of the assembly. UNIT STTS YPSUM O Type SX US ORL ZWWI RYWLL L L SZ Type SX J. ypsum oard* (Not Shown) - (s an alternate to Item when used as the base layer on one or both sides of wall. or direct attachment only to steel studs Item ) - Nom / in. thick lead backed gypsum panels with beveled, square or tapered edges, applied vertically. Vertical joints centered over studs and staggered min stud cavity on opposite sides of studs. ypsum board secured to studs with -/ in. long Type S- steel screws spaced in. O at perimeter and in. O in the field. To be used with Lead atten Strips (see Item ) or Lead iscs (see Item ). MYO INUSTRIS IN Type X-Ray Shielded ypsum K. ypsum oard* (s an alternate to Item and, not for use with Items,, and ) - Nom. / in. thick gypsum panels with beveled, square or tapered edges installed as described in Item and. IN Type ULX UNIT STTS YPSUM O Type ULX US MXIO S V Type ULX L. ypsum oard* (Not Shown) - (s an alternate to Item when used as the base layer on one or both sides of wall. or direct attachment only to steel studs Item ). Nom / in. thick lead backed gypsum panels with beveled, square or tapered edges, applied vertically. Vertical joints centered over studs and staggered min stud cavity on opposite sides of studs. Wallboard secured to studs with -/ in. long Type S- steel screws gypsum panel steel screws spaced in. O at perimeter and in. O in the field. Lead batten strips required behind vertical joints of lead backed gypsum wallboard and optional at remaining stud locations. Lead batten strips, min in. wide, max ft long with a max thickness of 0. in. placed on the face of studs and attached to the stud with construction adhesive and two in. long Type S- pan head steel screws, one at the top of the strip and one at the bottom of the strip. Lead discs, nominal / in. diam by max 0.0 in. thick. ompression fitted or adhered over the screw heads. Lead batten strips and discs to have a purity of.% meeting the ederal specification QQ-L-0f, rade "". RITION PROTTION PROUTS IN Type RPP - Lead Lined rywall M. ypsum oard* (or use with Item ) - / in. thick, ft wide, applied vertically over Mineral and iber oard (Item ) with vertical joints located anywhere over stud cavities. Secured to mineral and fiber boards with -/ in. Type Screws spaced in. O along edges of each vertical joint and in. O in intermediate field of the Mineral and iber oard (Item ). Secured to outermost studs and floor and ceiling runners with in. long Type S screws spaced in. O. ypsum oard joints covered with paper tape and joint compound. Screw heads covered with joint compound. MRIN YPSUM O Type - RTINT YPSUM IN Type RP, Type IN Types, IP-X, IP-R ONTINNTL UILIN PROUTS OPRTIN O, L L Type L- / ORI-PII YPSUM L L Types, P, T- NTIONL YPSUM O Types exp-, SK-, SW- PO UILIN PROUTS L L, PO YPSUM Type P-. PNL RY S Type PR TI YPSUM PROUTS PL Type UNIT STTS YPSUM O Types, IP-X, IP-R US ORL ZWWI RYWLL L L SZ Type US MXIO S V Types, IP-X, IP-R N. Wall and Partition acings and ccessories* (s an alternate to Item ) Nominal / in. thick, ft wide panels, applied vertically and secured as described in Item. PO UILIN PROUTS L L, PO YPSUM Type QuietRock. O. ypsum oard* s an alternate to Items,,, and - Two layers Nom. / in. thick gypsum panels applied vertically or horizontally. orizontal edge joints and horizontal butt joints on opposite sides of studs need not be staggered or backed by steel framing. orizontal joints on the same side need not be staggered. When applied horizontally, both layers of gypsum board fastened to each side of framing with in. long Type S steel screws spaced in. O and staggered in. O between layers. When applied vertically, both layers of gypsum board fastened to each side of framing with in. long Type S steel screws spaced in. O along vertical edges and in. O in the field, staggered in. O between layers. Screws spaced a max in. along the top and bottom edges of the wall. NTIONL YPSUM O Type SW. P. ypsum oard* s an alternate to Item. or use with Item, atts and lankets* - / in. thick, ft wide, attached to steel studs and floor and ceiling track with in. long, Type S steel screws spaced in. O. along edges of board and in. O in the field of the board. Joints oriented vertically and staggered on opposite sides of the assembly. When attached to item (resilient channels) or, or (furring channels), gypsum board is screw attached to furring channels with in. long, Type S steel screws spaced in. O. UNIT STTS YPSUM O Types ULIX. Joint Tape and ompound Vinyl, dry or premixed joint compound, applied in two coats to joints and screw heads; paper tape, in. wide, embedded in first layer of compound over all joints. s an alternate, nominal / in. thick gypsum veneer plaster may be applied to the entire surface of lassified veneer baseboard. Joints reinforced. Paper tape and joint compound may be omitted when gypsum boards are supplied with square edges.. Resilient hannel (Optional-Not Shown) MS galv steel resilient channels spaced vertically max in. O, flange portion attached to each intersecting stud with / in. long type S- pan head steel screws. May not be used with Item or J.. Steel raming Members (Not Shown)* s an alternate to Item, furring channels and resilient sound isolation clip as described below: a. urring hannels ormed of No. MS galv steel. -/ in. or -/ in. wide by / in. deep, spaced in. O perpendicular to studs. hannels secured to studs as described in Item b. nds of adjoining channels are overlapped in. and tied together with double strand of No. SW galv steel wire near each end of overlap. s an alternate, ends of adjoining channels may be overlapped in. and secured together with two self-tapping No. framing screws, min / in. long at the midpoint of the overlap, with one screw on each flange of the channel. b. raming Members* Used to attach furring channels (Item a) to studs (Item ). lips spaced in. O., and secured to studs with -/ in. wafer or hex head Type S steel screw through the center grommet. urring channels are friction fitted into clips. RSI- clip for use with -/ in. wide furring channels. RSI- (.) clip for use with - / in. wide furring channels. P INTRNTIONL L L Types RSI-, RSI- (.).. raming Members* (Not Shown) (Optional on one or both sides) s an alternate to Item, furring channel and Steel raming Members as described below: a. urring hannels ormed of No. MS galv steel. -/ in. wide by / in. deep, spaced max. in. O perpendicular to studs. hannels secured to studs as described in Item b. ypsum board attached to furring channels as described in Item. b. Steel raming Members* Used to attach furring channels (Item a) to studs (Item ). lips spaced max. in. O. NILIPS secured to studs with No. x -/ in. minimum self-drilling, S- steel screw through the center grommet. urring channels are friction fitted into clips. PLITQ IN Type enie lip. Steel raming Members (Optional, Not Shown)* - urring channels and resilient sound isolation clip as described below: a. urring hannels ormed of No. MS galv steel. Spaced in. O perpendicular to studs. hannels secured to studs as described in Item b. nds of adjoining channels overlapped in. and secured together with four self-tapping No. x/ Self rilling screws ( per side in. and in. from overlap edge). ypsum board attached to furring channels as described in Item. Side joint furring channels shall be attached to studs with RSILMOUNT Sound Isolation lips - Type R located approximately in. from each end of length of channel. oth ypsum oards at side joints fastened into channel with screws spaced in. O, approximately / in. from joint edge. b. Steel raming Members* Resilient sound isolation clip used to attach furring channels (Item a) to studs. lips spaced in. O., and secured to studs with No. x -/ in. coarse drywall screw through the center hole. urring channels are friction fitted into clips. STUO UILIN SYSTMS RSILMOUNT Sound Isolation lips - Type R. Wall and Partition acings and ccessories* (Optional, Not shown) Nominal / in. thick, ft wide panels, for optional use as an additional layer on one or both sides of the assembly. Panels attached in accordance with manufacturer's recommendations. When the QR-00 or QR- panel is installed between the steel framing and the UL lassified gypsum board, the required UL lassified gypsum board layer(s) is/are to be installed as indicated as to fastener type and spacing, except that the required fastener length shall be increased by a minimum of / in. Not evaluated or intended as a substitute for the required layer(s) of UL lassified ypsum oard. PO UILIN PROUTS L L, PO YPSUM Type QuietRock QR-00 and QR-. Mineral and iber oard* (Optional, Not shown) or optional use as an additional layer on one side of wall. Nom / in. thick, ft wide with long dimension parallel and centered over studs. ttached to studs and floor and ceiling runners with -/ in. long Type S steel screws, spaced in. O and in. O along all intermediate framing. The required UL lassified gypsum board layer (Item M) is to be installed over the Mineral and iber oards. atts and lankets, Item, and dhesive, Item, are required. OMSOT O omasote Type 0-. Lead atten Strips (Not Shown, or Use With Item ) - Lead batten strips, min -/ in. wide, max ft long with a max thickness of 0. in. Strips placed on the interior face of studs and attached from the exterior face of the stud with two in. long Type S- pan head steel screws, one at the top of the strip and one at the bottom of the strip. Lead batten strips to have a purity of.% meeting the ederal specification QQ-L-0f, rade "". Lead batten strips required behind vertical joints of lead backed gypsum board (Item ) and optional at remaining stud locations. Required behind vertical joints.. Lead atten Strips (Not Shown, for use with Item J) Lead batten strips, in. wide, max ft long with a max thickness of 0. in. Strips placed on the face of studs and attached to the stud with two min. in. long min. Type S- pan head steel screws, one at the top of the strip and one at the bottom of the strip or with one min. in. long min. Type S- pan head steel screw at the top of the strip. Lead batten strips to have a purity of.% meeting the ederal specification QQ-L-0f, rades ", or ". Lead batten strips required behind vertical joints of lead backed gypsum wallboard (Item J) and optional at remaining stud locations.. Lead iscs or Tabs (Not Shown, or Use With Item ) - Used in lieu of or in addition to the lead batten strips (Item ) or optional at other locations - Max / in. diam by max 0. in. thick lead discs compression fitted or adhered over steel screw heads or max / in. by -/ in. by max 0. in. thick lead tabs placed on gypsum boards (Item ) underneath screw locations prior to the installation of the screws. Lead discs or tabs to have a purity of.% meeting the ederal specification QQ-L-0f, rade "".. Lead iscs (Not Shown, for use with Item J) Max / in. diam by max 0. in. thick lead discs compression fitted or adhered over steel screw heads. Lead discs to have a purity of.% meeting the ederal Specification QQ-L-0f, rades ", or ".. dhesive Not Shown - (or use with Item ) - onstruction grade adhesive applied in vertical, serpentine, nominal / in. wide beads down the length of both vertical edges of Mineral and iber oard (Item ).. Wall and Partition acings and ccessories* (Optional, Not Shown) or use with Items to I, Items to J, Item, Items to I, Item and Item. or maximum fire rating of hour. On one side of the wall, over the first layer of ypsum oard (Item to Item I), install RefleXor membrane with the gold side facing outwards. Membrane installed with T0 staples spaced inches on center in both directions as per manufacturer's instructions, seams in membrane to be overlapped by inches. When RefleXor membrane is used an additional layer of ypsum oard that is identical to the one used in the first layer and as specified in Item to Item I shall be installed over the membrane. The additional layer of ypsum oard to be installed through the membrane to the stud as specified in Item to Item I except the fastener length shall be increased by a minimum of / inch. Install atts and lankets in the stud cavity as per Item. On the other side of the wall, prior to the installation of the ypsum oard, install Resilient hannels as per Item. Over the Resilient hannels install inch thick SONOpan panel secured to the Resilient hannels with drywall screws and washers spaced at in. O on the perimeter of the panel and in. O in the field of the panel. Over the SONOpan panel install the same ypsum oard as specified in Item to Item I with the fastener length increased by minimum / inch. Not evaluated or intended as a substitute for the required layer(s) of UL lassified ypsum oard. MSL RefleXor membrane, SONOpan panel * Indicates such products shall bear the UL or cul ertification Mark for jurisdictions employing the UL or cul ertification (such as anada), Last Updated on 0-- U. loor and eiling Runner (Not Shown) Min. MS galv steel, in. return legs, -/ in. deep (min), attached to floor and ceiling with fasteners in. O max.. raming Members* loor and eiling Runners (Not shown) s an alternate to Item - or use with Item, channel shaped, min -/ in. deep, attached to floor and ceiling with fasteners in. O. max. LLSTL & YPSUM PROUTS IN Type SRM raming System LIORNI XPN MTL PROUTS O Viper0 Track ONSOLIT RITORS ORP, UILIN PROUTS IV Type SRM raming System MRINO/WR, IV O WR INUSTRIS IN Viper0 Track PILLIPS M O L L Viper0 Track QUIL RUN UILIN MTRILS IN Type SRM raming System SO STL STU MNUTURIN O Type SRM raming System STL ONSTRUTION SYSTMS IN Type SRM raming System UNIT MTL PROUTS IN Type SRM raming System UNIT MTL PROUTS IN Type SRM raming System. loor and eiling Runners (Not shown) or use with Item - hannel shaped, fabricated from min 0 MS corrosion-protected or galv steel, min width to accommodate stud size, with min in. long legs, attached to floor and ceiling with fasteners spaced max in. O.. raming Members* loor and eiling Runners (Not shown) s an alternate to Item - or use with Item, channel shaped, min -/ in. wide fabricated from min 0.0 in. thick galv steel, attached to floor and ceiling with fasteners in. O. max. LRKITRI UILIN SYSTMS ProTRK MWS L L ProTRK M MTL RMIN ProTRK RM SLS L L Ram ProTRK STL STRUTURL PROUTS L L Tri-S ProTRK. raming Members* loor and eiling Runners (Not shown) s an alternate to Item - or use with Item, channel shaped, min -/ in. wide fabricated from min 0.0 in. thick galv steel, attached to floor and ceiling with fasteners in. O. max. TLLIN INUSTRIS L L TRU-TRK. raming Members* loor and eiling Runners (Not shown) s an alternate to Item - or use with Item, channel shaped, min -/ in. wide fabricated from min MS steel, attached to floor and ceiling with fasteners in. O. max. KIRII (ON KON) LT Type KIRII. loor and eiling Runners (Not shown) hannel shaped, fabricated from min 0.0 in. galv steel, min width to accommodate stud size, with min in. long legs, for use with studs specified below and fabricated from min 0.0 in. galv steel or thicker, attached to floor and ceiling with fasteners spaced max in. O. MRINO/WR, IV O WR INUSTRIS IN Viper0 Track VT0.. raming Members* loor and eiling Runners (Not shown) s an alternate to Item - or use with Item, channel shaped, min -/ in. deep, attached to floor and ceiling with fasteners in. O. max. TLLIN INUSTRIS L L Viper0 Track. raming Members* loor and eiling Runners (Not Shown) s an alternate to Item - or use with Item J. hannel shaped, attached to floor and ceiling with fasteners in. O. max. ILY MTL PROUTS LT Type PLTINUM PLUS. Steel Studs Min -/ in. deep, formed of min MS galv steel max stud spacing in. O. Studs to be cut / in. less than assembly height.. raming Members* Steel Studs s an alternate to Item - or use with Item, channel shaped studs, min -/ in. deep, spaced a max of in. O. Studs to be cut / in. less than assembly height. LLSTL & YPSUM PROUTS IN Type SRM raming System LIORNI XPN MTL PROUTS O Viper0 ONSOLIT RITORS ORP, UILIN PROUTS IV Type SRM raming System MRINO/WR, IV O WR INUSTRIS IN Viper0 PILLIPS M O L L Viper0 QUIL RUN UILIN MTRILS IN Type SRM raming System SO STL STU MNUTURIN O Type SRM raming System STL ONSTRUTION SYSTMS IN Type SRM raming System UNIT MTL PROUTS IN Type SRM raming System. Steel Studs (s an alternate to Item, or use with Item ) hannel shaped, fabricated from min 0 MS corrosion-protected or galv steel, -/ in. min depth, spaced a max of in. O. Studs friction-fit into floor and ceiling runners. Studs to be cut / to / in. less than assembly height.. raming Members* Steel Studs s an alternate to Item - or use with Item, channel shaped studs, min -/ in. wide fabricated from min 0.0 in. thick galv steel, spaced a max of in. O. Studs to be cut / in. less than assembly height. LRKITRI UILIN SYSTMS ProSTU MWS L L ProSTU M MTL RMIN ProSTU RM SLS L L Ram ProSTU STL STRUTURL PROUTS L L Tri-S ProSTU. raming Members* Steel Studs s an alternate to Item - or use with Item, channel shaped studs, min -/ in. wide fabricated from min 0.0 in. thick galv steel, spaced a max of in. O. Studs to be cut / in. less than assembly height. TLLIN INUSTRIS L L TRU-STU. raming Members* Steel Studs s an alternate to Item - or use with Item, channel shaped studs, min -/ in. wide fabricated from min MS steel, spaced a max of in. O. Studs to be cut / in. less than assembly height. KIRII (ON KON) LT Type KIRII. raming Members* Steel Studs s an alternate to Item - or use with Item, channel shaped studs, min -/ in. deep, spaced a max of in. O. Studs to be cut / in. less than assembly height. TLLIN INUSTRIS L L Viper0. raming Members* Steel Studs s an alternate to Item - or use with Item, channel shaped studs, Min -/ in. deep, formed of min MS galv steel max stud spacing in. O. Studs to be cut / in. less than assembly height. MéTL IN Stud. raming Members* Steel Studs s an alternate to Item - or use with Item, channel shaped studs, Min -/ in. deep, formed of min MS galv steel max stud spacing in. O. Studs to be cut / in. less than assembly height. OLMR SPLY IN PRIMSTU I. raming Members* - Steel Studs s an alternate to Item - or use with Item (-/ in. wide track), channel shaped studs, fabricated from min MS corrosion-protected steel, -/ in. wide by -/ in. deep, spaced a max of in. O. Studs to be cut / to / in. less than assembly height. MRINO/WR, IV O WR INUSTRIS IN StudRite J. raming Members* Steel Studs s an alternate to Item - or use with Item, channel shaped, min -/ in. wide, spaced a max of in. O. Studs to be cut / to / in. less than assembly height. ILY MTL PROUTS LT Type PLTINUM PLUS. atts and lankets* (Optional) Mineral wool or glass fiber batts partially or completely filling stud cavity. See atts and lankets (ZJZ) category for names of manufacturers.. iber, Sprayed* s an alternate to atts and lankets (Item ) (0% orate ormulation) Spray applied cellulose material. The fiber is applied with water to completely fill the enclosed cavity in accordance with the application instructions supplied with the product with a nominal dry density of. lb/ft. lternate pplication Method: The fiber is applied without water or adhesive at a nominal dry density of. lb/ft, in accordance with the application instructions supplied with the product. U S RNIR L L INS& INS for use with wet or dry application. INSL and INS0L are to be used for dry application only.. iber, Sprayed* s an alternate to atts and lankets (Item ) and Item - Spray applied cellulose insulation material. The fiber is applied with water to interior surfaces in accordance with the application instructions supplied with the product. pplied to completely fill the enclosed cavity. Minimum dry density of. pounds per cubic ft. NU-WOOL O IN ellulose Insulation. iber, Sprayed* s an alternate to atts and lankets (Item ) - Spray applied cellulose fiber. The fiber is applied with water to completely fill the enclosed cavity in accordance with the application instructions supplied with the product. The minimum dry density shall be.0 lbs/ft. INTRNTIONL LLULOS ORP elbar-rl. ypsum oard* / in. thick, outer layer paper, glass mat or vinyl surfaced. (Laminated System) ypsum board applied vertically in two layers. Inner layer attached to studs with in. long Type S steel screws spaced in. O along vertical edges, and in. O in the field and outer layer laminated to inner layer with joint compound, applied with a notched spreader producing continuous beads of compound about / in. in diameter, spaced not greater than in. O. Joints of laminated outer layer offset in. from inner layer joints Outer layer gypsum board attached to floor and ceiling runner track with -/ in. long Type S steel screws spaced in. O. Optional, (irect ttached System), Inner layer attached to studs with in. long Type S steel screws spaced in. O in the field and along the vertical edges. Outer layer attached to the studs over the inner layer with -/ in. long Type S steel screws spaced in. O in the field and along the vertical edges and in. O to the floor and ceiling runners. Joints of screw-attached outer layer offset from inner layer joints. Joints of outer layer may be taped or untaped. Nom / in. thick gypsum veneer plaster may be applied to the entire surface of lassified veneer baseboard. Joints reinforced. I RYWLL SPLIS LT Type X, / Type X, Type lueglass xterior Sheathing MRIN YPSUM O Types -, X-, M-lass, X-. IJIN NW UILIN MTRILS PULI LT O Type X-. RTINT YPSUM IN Types, RP, R, lasroc, Type X, Type X-, Type or /" asi-lite Type X. IN Type R,, IP-R, IP-X, IP-X, IP-R, SX, SX, USX, WR or WRX. esign No. U March, 0 Nonbearing Wall Rating R. * Indicates such products shall bear the UL or cul ertification Mark for jurisdictions employing the UL or cul ertification (such as anada), ONTINNTL UILIN PROUTS OPRTIN O, L L Types L, L, L-/, L-W, LLLX. ORI-PII YPSUM L L Types,,,, P,,, P,, S, PS, LS, T-, Type X, Veneer Plaster ase-type X, Water Rated-Type X, Sheathing Type-X, Soffit-Type X, reenlass Type X, Type X omfortuard Sound eadening ypsum oard, Type LWX, Veneer Plaster ase-type LWX, Water Rated-Type LWX, Sheathing Type-LWX, Soffit- Type LWX, Type LW, Water Rated-Type LW, Sheathing Type- LW, Soffit-Type LW, Type LWX, Veneer Plaster ase - Type LWX, Water Rated - Type LWX, Sheathing - Type LWX, Soffit - Type LWX, Type LW, Water Rated - Type LW, Sheathing - Type LW. NTIONL YPSUM O Types exp-, SK, SK-, SW, SW-, SW-, SW-, SW-, SW-, SW-, SMR-, SL, Soundreak XP Type X ypsum oard. PO UILIN PROUTS L L, PO YPSUM Type, P-, P-, P-, P-, P-, PS-WRS. PNL RY S Types RX, PRX, RX, MX, TX or PR. SIM YPSUM INUSTRY (SRURI) O LT Type X- TI YPSUM PROUTS PL Type or Type X UNIT STTS YPSUM O Type R,, RX-, IP-R, IP-X, IP-X, IP-R, SX, SX, SX, USX, WR, WRX. US ORL ZWWI RYWLL L L SZ Types, SX US MXIO S V Type R,, IP-R, IP-X, IP-X, IP-R, SX, SX, USX, WR or WRX.. ypsum oard* (s an alternate to Item ) Nom / in. thick, installed as described in Item with -/ in. long Type S screws for inner layer and -/ in. long Type S screws for outer layer. IN Types R, IP-R. UNIT STTS YPSUM O Types R, IP-R. US MXIO S V Types R, IP-R.. ypsum oard* (s an alternate to Item and ) / in. thick, to in. wide, applied horizontally as the outer layer to one side of the assembly. orizontal joints need not be backed by steel framing. Secured as described in Item for the direct attached system. When used in widths other than in., gypsum panels to be installed horizontally. RTINT YPSUM IN Type X, Type. IN Type SX. TI YPSUM PROUTS PL Type X, Type. UNIT STTS YPSUM O Type SX, RX-. US MXIO S V Type SX.. ypsum oard* (s an alternate to Items, and ) Two layers of / in. thick gypsum board applied horizontally or vertically. Inner layer attached to studs with No. by in. long Type S bugle head screws spaced in. O along the top and bottom tracks starting in. and then in. from the vertical edge. Inner layer screws spaced in. O along the studs, starting in. and then in. from the top and bottom of the studs and starting -/ in. from the horizontal joints when installed horizontally. Outer layer attached to studs with -/ in. long Type S bugle head screws spaced in. O along the top and bottom tracks starting -/ in. from the vertical edge. Outer layer screws spaced in. O along the studs, starting -/ in. and then in. from the top and bottom of the studs and starting -/ in. and then in. from the horizontal joints when installed horizontally. Vertical joints centered over studs and staggered one stud cavity on opposite sides of studs. Vertical joints in adjacent layers staggered one stud cavity. orizontal joints need not be backed by steel framing. orizontal edge joints and horizontal butt joints on opposite sides of studs need not be staggered. orizontal edge joints and horizontal butt joints in adjacent layers staggered a min of in. When outer layers are installed horizontally, vinyl or casein, dry or premixed joint compound shall be applied in two coats to joints and screw heads of outer layer. Paper tape, nom in. wide, embedded in first layer of compound over all joints of outer layer panels. Nom / in. thick gypsum veneer plaster may be applied to the entire surface of lassified veneer baseboard. Joints reinforced. ORI-PII YPSUM L L Types,,,, P,,, P,, S, PS, LS, T-, Type X, Veneer Plaster ase-type X, Water Rated-Type X, Sheathing Type-X, Soffit-Type X, reenlass Type X, Type X omfortuard Sound eadening ypsum oard, Type LWX, Veneer Plaster ase-type LWX, Water Rated-Type LWX, Sheathing Type-LWX, Soffit- Type LWX, Type LW, Water Rated-Type LW, Sheathing Type- LW, Soffit-Type LW, Type LWX, Veneer Plaster ase - Type LWX, Water Rated - Type LWX, Sheathing - Type LWX, Soffit - Type LWX, Type LW, Water Rated - Type LW, Sheathing - Type LW.. ypsum oard* (Not Shown) - (s an alternate to Item when used as the base layer on one or both sides of wall. or direct attachment only to steel studs Item ) - Nom / in. thick lead backed gypsum panels with beveled, square or tapered edges, applied vertically. Vertical joints centered over studs and staggered min stud cavity on opposite sides of studs. ypsum board secured to studs with -/ in. long Type S- steel screws spaced in. O at perimeter and in. O in the field. RY-R NINRIN ORP Type R-L. ypsum oard* (s an alternate to Items through ) Nominal / in. thick, ft wide panels, applied vertically and secured as described in Item. PO UILIN PROUTS L L, PO YPSUM Types QuietRock S.. ypsum oard* (s an alternate to Items through ) - / in. thick, ft. wide, paper surfaced, applied vertically and secured as described in Item. RTINT YPSUM IN Type SilentX. ypsum oard* s an alternate to Item - Nom. / in. thick, inner layer attached vertically to studs with in. long Type S steel screws spaced in. O in the field and along the vertical edges. Outer layer attached to the studs horizontally over the inner layer with -/ in. long Type S steel screws spaced in. O in the field and along the vertical edges and in. O to the floor and ceiling runners. Joints of outer layer must be taped. Nom / in. thick gypsum veneer plaster may be applied to the entire surface of lassified veneer baseboard. I RYWLL SPLIS LT Type lueglass xterior Sheathing PO UILIN PROUTS L L, PO YPSUM Types, P-, PS- WRS.. ypsum oard* (Not Shown) - (s an alternate to Items ) or irect pplication to Studs Only- or use as the base layer on one or both sides of the wall. Nom / in. thick lead backed gypsum panels with beveled, square or tapered edges, applied vertically. Vertical joints centered over studs and staggered min stud cavity on opposite sides of studs. Wallboard secured to studs with -/ in. long Type S steel screws spaced in. O at perimeter and in O in the field. Lead batten strips required behind vertical joints of lead backed gypsum wallboard and optional at remaining stud locations. asteners for face layer gypsum panels when installed over lead backed board to be min -/ in. Type S- bugle head steel screws spaced as described in Item. To be used with Lead atten Strips (see Item ) or Lead iscs (see Item ). MYO INUSTRIS IN Type X-Ray Shielded ypsum I. ypsum oard* (s an alternate to Item, not for use with Items and ) - Nom. / in. thick gypsum panels with beveled, square or tapered edges installed as described in Item. IN Type ULX UNIT STTS YPSUM O Type ULX. US MXIO S V Type ULX J. ypsum oard* (s an alternate to Item when used as the base layer on one or both sides of wall. or direct attachment only to steel studs Item ). Nom / in. thick lead backed gypsum panels with beveled, square or tapered edges, applied vertically. Vertical joints centered over studs and staggered min stud cavity on opposite sides of studs. Wallboard secured to studs with -/ in. long Type S- steel screws gypsum panel steel screws spaced in. O at perimeter and in. O in the field. Lead batten strips required behind vertical joints of lead backed gypsum wallboard and optional at remaining stud locations. Lead batten strips, min in. wide, max ft long with a max thickness of 0. in. placed on the face of studs and attached to the stud with construction adhesive and two in. long Type S- pan head steel screws, one at the top of the strip and one at the bottom of the strip. Lead discs, nominal / in. diam by max 0.0 in. thick. ompression fitted or adhered over the screw heads. Lead batten strips and discs to have a purity of.% meeting the ederal specification QQ-L-0f, rade "". RITION PROTTION PROUTS IN Type RPP - Lead Lined rywall K. ypsum oard (s an alternate to Items through J, not for use with Items and ). Two layers of nominal mm thick gypsum board applied vertically. Inner layer attached to studs with No.. x -/ in. long bugle head, self-drilling screws spaced -/ in. O in the field and -/ in. O in the perimeter, with the first screw in. from the edge. Outer layer attached to the studs over the inner layer with No.. x -/ in. long bugle head, self-drilling screws spaced -/ in. O in the field and -/ in. O in the perimeter, with the first screw / in. from the edge. Outer layer screws staggered from inner layer screws. Vertical joints centered over studs and staggered one stud cavity on opposite sides of studs. Vertical joints in adjacent layer staggered one stud cavity. Self-adhesive fiberglass mesh (x mesh) tape, nom in. wide, applied over all joints of outer layer panels. ry or premixed joint compound applied in two coats to joints over the mesh tape and screw heads of outer layer. YPSMN O LL Types MRW, W, T. L. ypsum oard* (s an alternate to Items through K) - Two layers of / in. thick gypsum board applied vertically or horizontally. Inner layer attached to studs with # x in. long bugle head screws spaced in. O along the top and bottom tracks and in. O in the field and along the vertical edges. Outer layer attached to studs with # x -/ in. long bugle head screws spaced in. O along the top and bottom tracks and in. O in the field and along the vertical edges. Vertical joints are centered over studs and staggered between layers and on opposite sides of the wall. orizontal joints on the face layer are staggered in. from the base layer. orizontal joints need not to be backed by steel framing. ONTINNTL UILIN PROUTS OPRTIN O, L L Type L, L- /. M. Wall and Partition acings and ccessories* (s an alternate to Items through L) Nominal / in. thick, ft wide panels, applied vertically and secured as described in Item. PO UILIN PROUTS L L, PO YPSUM Type QuietRock. N. ypsum oard* (s an alternate to Item through M) - or direct application to studs only - our layers nom. / in. thick gypsum panels applied vertically or horizontally. When applied horizontally, base layer secured to studs with in. Type S screws spaced in. O. Second layer installed with joints offset in. from base layer and secured with in. Type S screws spaced in. O. Third layer installed with joints in line with base layer and secured with -/ in. Type S screws spaced in. O. ourth layer installed with joints in line with second layer and secured with -/ in. Type S screws spaced in. O. or all layers, screws offset in. from previous layer. When applied vertically, base layer secured with in. Type S screws spaced in. O. Second layer secured with joints offset one stud cavity and secured with in. Type S screws spaced in. O. Third layer installed with joints in line with base layer and secured with -/ in. Type S screws spaced in. O. ourth layer secured with joints in line with second layer and secured with -/ in. Type S screws spaced in. O along vertical edges and in. O in the field. or all layers, screws offset in. from previous layer. NTIONL YPSUM O Type SW O. ypsum oard* (s an alternate to Item ) / in. thick gypsum panels. (Laminated System) ypsum board applied horizontally or vertically in two layers. Inner layer attached to studs with in. long Type S steel screws spaced in. O along vertical edges, and in. O in the field and outer layer laminated to inner layer with joint compound, applied with a notched spreader producing continuous beads of compound about / in. in diameter, spaced not greater than in. O. Joints of laminated outer layer need not be offset from inner layer joints. Outer layer gypsum board attached to floor and ceiling runner track with -/ in. long Type S steel screws spaced in. O. Optional (irect ttached System), ypsum board applied horizontally or vertically in two layers. Inner layer attached to studs with in. long Type S steel screws spaced in. O in the field and along the vertical edges. Outer layer attached to the studs over the inner layer with -/ in. long Type S steel screws spaced in. O. Vertical and horizontal joints between inner and outer layers need not be staggered. Joints of outer layer may be taped or untaped. Nom / in. thick gypsum veneer plaster may be applied to the entire surface of lassified veneer baseboard. Joints reinforced. UNIT STTS YPSUM O Type ULIX.. Lead atten Strips (Not Shown, or Use With Item ) - Lead batten strips, min -/ in. wide, max ft long with a max thickness of 0. in. Strips placed on the interior face of studs and attached from the exterior face of the stud with two in. long Type S- pan head steel screws, one at the top of the strip and one at the bottom of the strip. Lead batten strips to have a purity of.% meeting the ederal specification QQ-L-0f, rade "". Lead batten strips required behind vertical joints of lead backed gypsum board (Item ) and optional at remaining stud locations. Required behind vertical joints.. Lead atten Strips (Not Shown, for use with Item ) Lead batten strips, in. wide, max ft long with a max thickness of0. in. Strips placed on the face of studs and attached to the stud with two min. in. long min. Type S- pan head steel screws, one at the top of the strip and one at the bottom of the strip or with one min. in. long min. Type S- pan head steel screw at the top of the strip. Lead batten strips to have a purity of.% meeting the ederal specification QQ-L-0f, rades ", or ". Lead batten strips required behind vertical joints of lead backed gypsum wallboard (Item ) and optional at remaining stud locations.. Lead iscs or Tabs (Not Shown, or Use With Item ) - Used in lieu of or in addition to the lead batten strips (Item ) or optional at other locations - Max / in. diam by max 0. in. thick lead discs compression fitted or adhered over steel screw heads or max / in. by -/ in. by max 0. in. thick lead tabs placed on gypsum boards (Item ) underneath screw locations prior to the installation of the screws. Lead discs or tabs to have a purity of.% meeting the ederal specification QQ-L-0f, rade "".. Lead iscs (Not Shown, for use with Item ) Max / in. diam by max0. in. thick lead discs compression fitted or adhered over steel screw heads. Lead discs to have a purity of.% meeting the ederal Specification QQ-L-0f, rades ", or ".. Mineral and iber oard* (Optional, Not shown) or optional use as an additional layer on one side of wall. Nom / in. thick, ft wide with long dimension parallel and centered over studs. ttached to studs and floor and ceiling runners with -/ in. long Type S steel screws, spaced in. O. The required UL lassified gypsum board layer(s) is/are to be installed as indicated as to fastener type and spacing, except that the required fastener length shall be increased by a minimum of / in. Not evaluated or intended as a substitute for the required layer(s) of UL lassified ypsum oard. OMSOT O omasote Type 0-. urring hannels (Optional, not shown- not for use with Items,, J, or N) Resilient furring channels fabricated from min MS corrosion-protected steel, spaced vertically a max of in. O. lange portion attached to each intersecting stud with / in. long Type S- steel screws.. raming Members* (Optional on one or both sides, not shown - not for use with Items,, J, or N) s an alternate to Item, furring channels and Steel raming Members as described below: a. urring hannels ormed of No. MS galv steel. -/ in. or -/ in. wide by / in. deep, spaced max. in. O perpendicular to studs. hannels secured to studs as described in Item b. b. Steel raming Members* Used to attach furring channels (Item a) to studs. lips spaced max. in. O. RSI- and RSI- (.) clips secured to studs with No. x -/ in. minimum self-drilling, S- steel screw through the center grommet. RSI-V and RSI-V (.) clips secured to studs with No. x / in. minimum selfdrilling, S- steel screw through the center hole. urring channels are friction fitted into clips. RSI- and RSI-V clips for use with -/ in. wide furring channels. RSI- (.) and RSI-V (.) clips for use with -/ in. wide furring channels. P INTRNTIONL L L Types RSI-, RSI-V, RSI- (.), RSI-V (.).. raming Members* (Optional on one or both sides, not shown - not for use with Items,, J, or N) s an alternate to Item, furring channels and Steel raming Members as described below: a. urring hannels ormed of No. MS galv steel. Spaced in. O perpendicular to studs. hannels secured to studs as described in Item b. nds of adjoining channels overlapped in. and secured together with four self-tapping No. x/ Self rilling screws ( per side in. and in. from overlap edge). ypsum board attached to furring channels as described in Item. Side joint furring channels shall be attached to studs with RSILMOUNT Sound Isolation lips - Type R located approximately in. from each end of length of channel. oth ypsum oards at side joints fastened into channel with screws spaced in. O, approximately / in. from joint edge. b. Steel raming Members* Resilient sound isolation clip used to attach furring channels (Item a) to studs. lips spaced in. O., and secured to studs with No. x -/ in. coarse drywall screw through the center hole. urring channels are friction fitted into clips. STUO UILIN SYSTMS RSILMOUNT Sound Isolation lips - Type R * Indicates such products shall bear the UL or cul ertification Mark for jurisdictions employing the UL or cul ertification (such as anada), Last Updated on 0-0- ISSU: K: SL: ST TITL: inal Plans for Pemit and idding RWN: 0 ST RNWY PLZ SUIT 00 OUSTON, TXS 0 P ONSULTNTS: IVIL: SSNR NINRIN STRUTURL: STNT MP: R NINRS //0 :0: PM " = '-0" hecker JMS RL RUR I SOOL ITIONS N RNOVTIONS RYN, TXS UL SSMLIS.000. March, 0 uthor

7 P0 N0 X0 esign No. P0 October, 0 Restrained ssembly Rating /,, -/ or r. (See Item ) Unrestrained ssembly Rating /,, -/ or r. (See Item ) Unrestrained eam Rating, -/ or r. (See Item ) This design was evaluated using a load design method other than the Limit States esign Method (e.g., Working Stress esign Method). or jurisdictions employing the Limit States esign Method, such as anada, a load restriction factor shall be used See uide XUV or XUV * Indicates such products shall bear the UL or cul ertification Mark for jurisdictions employing the UL or cul ertification (such as anada), eam Wx, min size or Steel Joist J, J or K min sizes (See Item ). s alternate to steel beam or steel joists, Joist girders (Not shown)-0 in. min depth and lb/lin ft min weight. s an alternate to steel beam or steel joists, any L- Series joist may be used.. Roof overing* onsisting of hot mopped or cold application materials compatible with insulation(s) described herein which provide lass, or coverings. See Roofing Materials and Systems irectory-roof overing Materials (TVT).. In lieu of Item, roof covering consisting of single-ply Roofing Membrane* that is either ballasted, adhered or mechanically attached as permitted under the respective manufacturer's lassification. See ire Resistance irectory-roofing Membranes (I).. Metal Roof eck Panels (Not shown) In addition to or in lieu of Items or, the roof covering may consist of a mechanically fastened metal roof deck panel assembly. See ire Resistance irectory-metal Roof eck Panels (TW).. Roof Insulation ) Mineral and iber oards* To be applied in one or more layers with or without adhesive applied between vapor barrier and roof deck units, vapor barrier and board, and each layer of board. When more than one layer is required, each layer of board to be offset in both directions from layer below a min of in. in order to lap all joints. Min thickness is in. when Item or is used. Min thickness is in. otherwise. M INSULTION PROUTS IN Permalite. TMP Perlite. JONS MNVILL ROXUL IN Monooard, Monooard Plus, "Monooard Plus S", TopRock, TopRock Plus or TopRock Plus S. SOPRM IN SopraRock M, SopraRock M Plus, SopraRock and SopraRock Plus. ) Or, / in. ypsum oard (lassified or Unclassified), supplied in ft wide sheets. Installed perpendicular to steel roof deck with end joints staggered a min of ft in adjacent rows and occurring over crests of steel roof deck. May be secured to crests of steel roof deck with dhesive* applied at a rate of 0. gal per 0 sq ft. See ypsum oard (KNX) category for names of manufacturers. See dhesives (YWR) category for names of manufacturers. a). nd, oamed Plastic*, min in. thick, max. pcf, polystyrene foamed plastic insulation boards secured with asphalt glaze coat, or laid loosely on gypsum wallboard. No max overall thickness. Note: dhesives and/or asphalt glaze coat may be omitted when Item is used. See oamed Plastic* (RYX) category in uilding Materials irectory or oamed Plastic* (VW) category in ire Resistance irectory for list of manufacturers. b). Or, oamed Plastic*, min. in. thick, may be laid loosely over roof covering or bonded to the single-ply membrane with adhesive or laid into the asphalt glaze coat. When applied in more than one layer, successive layers shall be installed over preceding layer without attachment. overed with stone or masonry ballast at a min. rate of psf. OWNS ORNIN OM INSULTION L L c). Or, uilding Units* pplied in one or more layers with or without adhesive. When more than one layer is required, the joints of each layer shall be staggered in. (min). Min thickness is in. when Item is used. Min thickness -/ in. otherwise. Max thickness is -/ in. PITTSUR ORNIN ORP T OW MIL O Type Styrofoam. d). Or oamed Plastic*, polyisocyanurate foamed plastic insulation boards, nominal by in, applied in one or more layers over the gypsum wallboard. Min thickness is. in. with no max overall thickness. When applied in more than one layer, each layer to be offset in both directions from layer below a min of in. in order to lap all joints. dhesive (Item or ) may be applied between layers of insulation and to vapor retarder (or gypsum wallboard if vapor retarder is not used). TLS ROOIN ORP oam II, oam III, oam-ii SL, oam IV. RLISL SYNT INORPORT Types P, P-, P-N, P-W. OW ROOIN SYSTMS L L "ow Termico Polyisocyanurate Insulation", "ow Termico ISO 000 Insulation", "ow Termico ISO P-R". YPLST PROUTS L L IRSTON UILIN PROUTS O L L "IS0 + L", "ISO + K", "ISO + W", "ISO 00", "ISO + N", "ISOR omposite oard" or "RSIST". nergyuard R, Tapered nergyuard R,, nergyuard, Isotherm R. UNTR PNLS Shield. JONS MNVILL NRY psi, NRY, Tapered NRY, Tapered NRY psi, NRY, Tapered NRY, NRY psi, Tapered NRY psi, NRY, Tapered NRY, NRY psi, Tapered NRY psi, ISO-, Tapered ISO-, ValuTherm, Tapered ValuTherm, ValuTherm psi, Tapered ValuTherm psi, ValuTherm, Tapered ValuTherm, ValuTherm psi, Tapered ValuTherm psi, ValuTherm, Tapered ValuTherm, ValuTherm psi, Tapered ValuTherm psi. LOMSTR SYSTMS IN Loadmaster Polyisocyanurate Insulation. MRTIN IRPROOIN ORP "Perform--eck I" RMX OPRTIN L L Multi-Max-, Multi-Max -, Ultra-Max, Ultra-Max Plus, Tapered Ultra-Max Plus, Tapered Thermaroof-, Tapered Thermaroof -, Tapered Ultra-Max. SIK SRNIL IN Sarnatherm r, Sarnatherm r Ultra, Sarnatherm r Tapered, Sarnatherm r Ultra Tapered. SOPRM IN Sopra-ISO s, Sopra-ISO s Tapered, Sopra-ISO+ s, Sopra-ISO+ s Tapered, Sopra-ISO + s, Sopra-ISO + s Tapered. e). Or uilding Units*, Polyisocyanurate foamed plastic insulation boards faced on underside (or both sides) with mineral fiber board. Min thickness of the polyisocyanurate core is. in. No limit on max overall thickness. oards to be installed with end joints staggered a min of in. in adjacent rows. dhesive (Item ) may be applied between the building units and the vapor retarder (or gypsum wallboard if vapor retarder is not used). IRSTON UILIN PROUTS O L L "ISO + omposite". JONS MNVILL esco-oam. f). Or uilding Units* Polyisocyanurate foamed plastic insulation boards, nom. by or in., faced on the top surface with oriented strand board or plywood. Min. thickness of the polyisocyanurate core is. in. No limit on max overall thickness. oards to be installed with end joints staggered a min. of in. in adjacent rows. dhesive (Item ) may be applied between the building units and the vapor retarder (or gypsum wallboard if vapor retarder is not used). TLS ROOIN ORP oam Nail ase Insulation, Vented-R, oam rossvent, oam III Nail ase Insulation, oam III rossvent IRSTON UILIN PROUTS O L L ailgard. JONS MNVILL Type Nailboard. SOPRM IN Sopra-ISO V s. g). or uilding Units* Polyisocyanurate foamed plastic insulation boards faced on the underside with wood fiber board. Min thickness of the polyisocyanurate core is. in. No limit on max overall thickness. oards to be installed with end joints staggered a min of in. in adjacent rows. IRSTON UILIN PROUTS O L L "ISO Wood iberboard omposite". JONS MNVILL "NRY- Plus. h). or uilding Units* Not Shown omposite polyisocyanurate foamed plastic insulation board with an adhered nailing surface, nom by or in. may be used with the following limitations. These composite building units have ventilation slots internal to the panels. The building units are applied over gypsum wallboard. The thickness of the panel depends upon the thinnest portion of the polyisocyanurate insulation. The following dimensions apply to the polyisocyanurate insulation, min. in. thick. There is no limit on the max insulation thickness. JONS MNVILL Type ISO-VNT. i). or uilding Units* Polyisocyanurate foamed plastic insulation boards, nom by or in., faced on the top surface with gypsum board. Min thickness of the polyisocyanurate core is. in. No limit on overall thickness. oards to be installed with end joints staggered a min of in. in adjacent rows. JONS MNVILL NRY ypsum omposite. j. Or Mineral and iber oards* (Not Shown - Optional) pplied in one or more layers over oamed Plastic (item d.) or uilding Units* (Items. e, f, g, h, i). / in. minimum thickness. JONS MNVILL esco oard, Retroit oard, uraoard k. or Roof Insulation - oamed Plastic* Not Shown - Optional, / in. thick. Placed over minimum -/ in. thick polyisocyanurate oamed Plastic (Item, d) may be applied with adhesive (Item ). oards to be installed with end joints to be offset in both directions from layer below a min of in. in order to lap all joints. JONS MNVILL Invinsa l. or Roof Insulation oamed Plastic* Polyurethane foamed plastic roof insulation. ormed by the simultaneous spraying of two liquid components applied over gypsum wallboard (item ) in accordance with the manufacturer's instructions. Min thickness is. in. witn no max overall thickness. S ORP Types 0., -, -., -., -., -.0, LSTOSPRY, LSTOSPRY, LSTOSPRY or LSTOSPRY.. S ORP lastospray 0-.0, lastospray 0-., lastospray, lastospray, lastospray lpha System, lastospray. oamed Plastic* Optional - (Not Shown) - Maximum in. thick polyisocyanurate foamed plastic insulation boards, nom by or in. oards may be applied as the top layer in addition to the specified minimum thickness of any roofing system described herein, as long as the roofing system states that there is no limit on maximum thickness. Joints offset in both directions from layer below. IRSTON UILIN PROUTS O L L "ISOR ". dhesive* Optional May be used with board insulation. pplied in / in. wide ribbons, approx in. O at 0. gal/0 sq ft. dhesive* -(Optional) (earing the UL lassification Marking for Roof Systems (TU)) - The vapor retarder, the gypsum wallboard or the first layer of roof insulation may be secured with adhesive to the steel crest surfaces. lso used to attach the vapor retarder to gypsum wallboard, the first layer of insulation to vapor retarder or gypsum wallboard and each additional layer of insulation. pplied at a max rate of. g/ft. When ST 0 adhesive is used, additional Spray-pplied ire Resistance Materials* (PX) is required on the deck for the -/ and hr Unrestrained ssembly Ratings. The thickness specified for the deck shall be increased by / in. for -/ hr Unrestrained ssembly Rating and / in. for hr Unrestrained ssembly Rating. RLISL SYNT INORPORT ST 0. Sheathing Material* Optional. Vinyl film or paper scrim vapor barrier applied with adhesive or laid loosely on the steel roof deck, overlapped approx in. at sides.. Sheathing Material* (Optional) self-adhered rubberized asphalt roofing underlayment membrane which may be placed on top of the gypsum wallboard (Item ) or on roof insulation (Item or any nonpolystyrene foamed plastic insulation covered as an alternate to Item ). W R R & O - ONN race Ice and Water Shield, race Ice and Water Shield-T, race Select, race Ultra, and race asik.. Steel Roof eck (Unclassified) Min -/ in. deep, in. wide, galv, fluted steel deck. lutes in. O, crest width ranging from -/ to in. Min gauge is MS. nds overlapped at supports min -/ in. and welded to supports approx in. O. djacent units button-punched or welded together in. O along side joints; or, lassified Steel loor and orm Units* -/ or in. deep, 0 or in. wide, galv steel units. Min gauge is MS. Spacing of welds attaching units to supports shall not exceed in. O. djacent units button-punched or welded together in. O along side joints. S STL K, IV O S PROILS L L Types -, N-, N- -/, -, -, N-, N--/, N-, NN-, N-, N-, NN-. ll units may be galvanized or Prime Shield. ll non-cellular decks may be vented designated with a "V" suffix to the product name. NM STL ORP in. wide Type P-0 and P- noncomposite; in. wide Type P-, P-0, P-0, and P- noncomposite. NM STL ORP Types, I,, NS and NI. Units may be ptd/ptd. NW MILLNNIUM UILIN SYSTMS L L or 0 in. wide Type ; 0 or in. wide Types, I, ; in. wide Types N, NI. Units may be ptd/ptd. K WST IN in. wide Types -W, -W; in. wide Type NW. MRLYN STL KS IN Types,, N, NV NW MILLNNIUM UILIN SYSTMS L L 0 in. or in. wide Types, I, ; in. wide Type N. or and -/ h ssembly and eam Ratings only, units may be phos/painted or galvanized. ROO K IN Types, -, - or. VRO KIN IN - NUOR O Types PL,, PLN or N ormlok. Units may be phos./ptd. Types PL, S, PLN or N ormlock; or Types PLN, SN. Units may be ptd/ptd. VULRT, IV O NUOR ORP, 0 or in. wide Types.,.,.I,.PL,.; in. wide Types N, NI,.0PLN. or and -/ h ssembly and eam Ratings only, the Types.,.,.I,.PL,., N, NI,.0PLN, units may be ptd/ptd; Types W, igh Strength, W igh Strength, N. Units may be phd/ptd.. Spray-pplied ire Resistive Materials* pplied by mixing with water and spraying in more than one coat to a final thickness as shown on the above illustration and in the table below, to steel surfaces which must be clean and free of dirt, loose scale and oil. Min avg and min ind density of / pcf Min avg and min ind density of / pcf respectively for Type P and. or method of density determination, refer to esign Information Section. Note: When metal lath is used on joist, full thickness Spray-pplied ire Resistive Materials is to be applied over the entire joist, including the lath. or method of density determination, refer to esign Information Section. When metal lath is required, as indicated below, full thickness Spray-pplied ire Resistive Materials is to be applied over the entire support including the lath. #The required minimum thickness of Spray-pplied ire Resistive Materials on the steel deck is increased by / in. for -/ hr Unrestrained ssembly Rating and / in. for hr Unrestrained ssembly Rating when Item is used. R KOR IN Types MK-/, MK-/, MK-/Y, MK-s, Monokote coustic. PYROK IN Type L. SOUTWST IRPROOIN PROUTS O Types,,, P, M, P,,, P, M,, P, M. W R R & O - ONN Types MK-/Y, MK-s, R, Monokote coustic.. lternate Spray-pplied ire Resistive Materials* pplied by mixing with water and spraying in more than one coat to a final thickness as shown on the above illustration and in the table below, to steel surfaces which must be clean and free of dirt, loose scale and oil. Min avg and min ind density of / pcf or method of density determination, refer to esign Information Section, Sprayed Materials. * Requires the use of / in. gypsum wallboard (Item ). ** alvanized steel roof units only. #The required minimum thickness of Spray-pplied ire Resistive Materials on the steel deck is increased by / in. for -/ hr Unrestrained ssembly Rating and / in. for hr Unrestrained ssembly Rating when Item is used. R KOR IN Types Monokote coustic, Z-, Z-/, Z-/Y. W R R & O - ONN Types Monokote coustic, Z-, Z-/, Z- /Y.. Metal Lath Where required The diamond mesh, / in. expanded steel lath,. to. lb/sq yd is secured to one side of each steel joist with No. SW galv steel wire at joist web and bottom chord members, spaced in. O max. Where not required, the optional use of metal lath described, fastened as above, may be used to facilitate the spray application of spray-applied resistive material on steel bar joists and trusses. In this application, the metal lath is to be fully covered with spray-applied resistive material with no minimum thickness required.. Nonmetallic fabric mesh (Optional, not shown) s an alternate to the optional use of metal lath, glass fiber fabric mesh, weighing approximately. oz/sq yd, polypropylene fabric mesh, weighing approximately. oz/sq yd or equivalent, may be used to facilitate the spray application. The mesh is secured to one side of each joist web member. The method of attaching the mesh must be sufficient to hold the mesh and the spray-applied spray-applied resistive material in place during application until it has cured. n acceptable method to attach the mesh is by embedding the mesh in minimum / in. long beads of hot melted glue. The beads of glue shall be spaced a maximum of in. O along the top chord of the bar joist. nother method to secure the mesh is by -/ in. long by / in. wide hairpin clips formed from No. SW or heavier steel wire.. ridging In accordance with Specifications adopted by the Steel Joist Institute and revised to November,. ontinuous steel angles, min. size -/ by -/ by / in. welded to top and bottom chords. ridging coated with -/ in. thickness of Spray-pplied ire Resistive Materials for the or -/ h ssembly and eam Ratings and -/ in. for the h ssembly and eam Ratings.. Metal Lath (Not Shown) Where Type is applied to steel deck, / in. metal ribbed lath weighing. lb/yd shall be secured to the underside of the steel deck (ribs upward) with S- by / in. long pan head, selftapping steel screws spaced in. O in all directions. Steel screws shall be fitted with / in. diameter steel washers. djacent pieces of lath shall be overlapped in. min. * Indicates such products shall bear the UL or cul ertification Mark for jurisdictions employing the UL or cul ertification (such as anada), Last Updated on 0-- esign No. N0 ugust, 0 (ormerly r., 0 r., r., r.) Restrained eam Ratings, -/,,, and r. Unrestrained eam Ratings, -/,,, and r. This design was evaluated using a load design method other than the Limit States esign Method (e.g., Working Stress esign Method). or jurisdictions employing the Limit States esign Method, such as anada, a load restriction factor shall be used See uide XUV or XUV * Indicates such products shall bear the UL or cul ertification Mark for jurisdictions employing the UL or cul ertification (such as anada),. Steel eam Min beam size for ratings shall be:. Normal Weight or Lightweight oncrete or normal weight concrete either carbonate or siliceous aggregate may be used. Unit weight pcf. or lightweight concrete, unit weight pcf.. Steel loor and orm Units* Min -/ to in. deep cellular or fluted type, welded to beam.. Spray-pplied ire Resistive Materials* pplied by mixing with water and spraying in more than one coat to beam and in one coat to steel deck to final thicknesses shown below. Steel surfaces must be clean and free of dirt, loose scale, and oil. Min avg and min ind density of / pcf Min avg and min ind density of / pcf respectively for Types P and. or method of density determination, refer to esign Information Section. Types, MK-/, R, VP, P, P,, P, P, may be used only with all fluted steel floor units or blends consisting of one or more fluted units to one in. wide max cellular unit, -/ or in. deep, with cells spaced approx and in. When fluted units are used, crest areas above the beam shall be filled with Spray-pplied ire Resistive Materials. The thicknesses of Spray-pplied ire Resistive Materials shown in the table below are applicable when the thickness applied to the beam's lower flange edges is reduced to one-half that shown in the table: RIN VRMIULIT INUSTRIS Types MK-/, MK-/, MK-/Y, MK- /, MK-, MK- xtended Set, MK-s, Sonophone. R KOR IN Types MK-/, MK-/, MK-/Y, MK-/, MK-, MK- xtended Set, MK-s, Monokote coustic. PYROK IN Type L. SOUTWST IRPROOIN PROUTS O Types,,, P, M, P,,, P, M,, P, M. W R R & O - ONN Types MK-/Y, MK-, MK- xtended Set, MK-/, MK-s, Monokote coustic, R. * Indicates such products shall bear the UL or cul ertification Mark for jurisdictions employing the UL or cul ertification (such as anada), Last Updated on 0-0- esign No. X0 ugust, 0 Ratings,, and r. * Indicates such products shall bear the UL or cul ertification Mark for jurisdictions employing the UL or cul ertification (such as anada),. Spray-pplied ire Resistive Materials* See table below for appropriate thickness. Min avg and min ind density of / pcf Min avg and min ind density of / pcf respectively for Types P and. Min avg and min ind density of 0/ pcf for Type V0. Min avg and min ind density of 0/ pcf for Type V00. or method of density determination, refer to esign Information Section, preceding these designs. The thicknesses contained in the table below are applicable when the Spray-pplied ire Resistive Materials applied to columns flange tips are reduced to one-half that shown in the table below: RIN VRMIULIT INUSTRIS Types V0 and V00 evaluated for xterior xposure. R KOR IN Types MK-/, MK-/, MK-/Y, MK-s, Monokote coustic. PYROK IN Type L. SOUTWST IRPROOIN PROUTS O Types,,, P, M, P,,, P, M,, P, M. W R R & O - ONN Types MK-/Y, MK-s, Monokote coustic, R.. Steel olumn Minimum size of column, Wx, with outside dimensions of x in., a flange thickness of / in., a web thickness of / in., and a cross-sectional area of. sq in. * Indicates such products shall bear the UL or cul ertification Mark for jurisdictions employing the UL or cul ertification (such as anada), 0 ST RNWY PLZ SUIT 00 OUSTON, TXS 0 P ONSULTNTS: IVIL: SSNR NINRIN STRUTURL: STNT MP: R NINRS inal Plans for Pemit and idding JMS RL RUR I SOOL ITIONS N RNOVTIONS RYN, TXS RWN: uthor K: SL: hecker " = '-0" ISSU: March, 0 ST TITL: UL SSMLIS / NVLOP OMPLIN K.000. //0 :0:00 PM

OR BUILDING PERMIT SHEET DATA PRELIMINARY NOT FOR CONSTRUCTION PROJECT. Author. Checker STAMP INTERIOR DESIGN: REVIEWED BY: DRAWN BY:

OR BUILDING PERMIT SHEET DATA PRELIMINARY NOT FOR CONSTRUCTION PROJECT. Author. Checker STAMP INTERIOR DESIGN: REVIEWED BY: DRAWN BY: 80 PRK VNU, LL 80 PRK VNU UP SUMITTL.5.03 PROJT ONTT INFORMTION OWNR RHITT ONTRTOR 80 Park venue, LL Onwuegbu rchitecture, LL. New Star General ontractors 590 Sidewinder r. 94 Parkridge rive 60 west 590

More information

G-001. hord coplan macht Reed St. Wheat Ridge, CO SCHEMATIC DESIGN 07/30/15. Jeffco Schools 7-12 Reconfiguration: Stevens Elem.

G-001. hord coplan macht Reed St. Wheat Ridge, CO SCHEMATIC DESIGN 07/30/15. Jeffco Schools 7-12 Reconfiguration: Stevens Elem. 5 hord coplan macht Nineteenth Street enver, O. 800 P 0.07.0977 www.hcm.com ONSULTNT: Jeffco Schools 7- Reconfiguration: Stevens lem. School 00 Reed St. SHMTI SIGN 07/0/5 PROJT: Jeffco Schools 7- Reconfiguration:

More information

PRILEX STEEL DETAILING LLC

PRILEX STEEL DETAILING LLC PRILX STL TILING Project: Mountain Tech enter RFI# Subject: Structural pproval Set & Revised esign Set Seq. # ate: //0 Originator: Gaston Fernandez References Structural approval set "000 Structural Steel

More information

A-206 POWDER SF 4'-11"x 10'-7" POCKET W/ (2) DOORS 1 A-204 FLATSCREEN T.V. LINE OF TERRACE ABOVE SLOPED. 6 x 9 WINDOW OPENING W/ GALLERY

A-206 POWDER SF 4'-11x 10'-7 POCKET W/ (2) DOORS 1 A-204 FLATSCREEN T.V. LINE OF TERRACE ABOVE SLOPED. 6 x 9 WINDOW OPENING W/ GALLERY POWR 4 S '" x '" 5 S 4'"x '" () TRSH.O. ate W.H. ISPLY S SHOWR OOR 4 S '" x '" UST LOST () 5 SMT () QTR. R. IX ( ) L. PNL () UST ROOM ( 4 5 S '" x '" WIN " ILIN Heat n lo Primo 4 UP R escription NTILVR

More information

EDUCATIONAL CLASS 1 EDUCATIONAL CLASS 2 ELEVATOR SKY LIGHT ABOVE PATIO /INNER COURTYARD FLOOR ABOVE BUILDING MG/ BOARD MEETING ROOM ADMIN ROOM 1

EDUCATIONAL CLASS 1 EDUCATIONAL CLASS 2 ELEVATOR SKY LIGHT ABOVE PATIO /INNER COURTYARD FLOOR ABOVE BUILDING MG/ BOARD MEETING ROOM ADMIN ROOM 1 Z YNTHI ZHORUK rchitect Inc..WSHRM 770 0 80 7000 970 40 4400 6 PHON - 90..4480 MIN NTRY 4 60 000 740 800 4 MIN NTRY UP 6 6 7 7. 799 479 VSTIUL LOY 700 NQUT ROOM 0800 690 YM OURT MIN STIR 000 7 4400 447

More information

GlasRoc Sheathing Type X

GlasRoc Sheathing Type X Wall / Fire-Rated Systems 3-5/8" (92 mm) Steel Studs ProRoc Steel Stud System 3-5/8" (92 mm) Steel Track 3-1/2" (89 mm) Glass Fiber or Mineral Wool Insulation GlasRoc Sheathing Type X UL Design U465 Cavity

More information

WAYNE STATE UNIVERSITY

WAYNE STATE UNIVERSITY 7 0 WYN STT UNIVRSITY STUNT NTR UILIN LOIN O L RPIRS STUNT NTR 7 aly Road West loomfield, Michigan - T..00..0 N Project No. 0-00 ULLN MLL TROIT, MI OWNR WYN STT UNIVRSITY SS VNU TROIT, MIIN 0 LOIN O 00

More information

E-0.1 TRIAD 41ST TRIAD CAPITAL TH AVENUE NE SEATTLE, WA SYMBOL SCHEDULE A S S O C I A T E S, I N C. REVISIONS

E-0.1 TRIAD 41ST TRIAD CAPITAL TH AVENUE NE SEATTLE, WA SYMBOL SCHEDULE A S S O C I A T E S, I N C. REVISIONS IL LOTION: :\\RWIN\TRI \-0. TRI - YMOL.W 0 P 9% T 0.. P UMITTL 0.0. MUP UMITTL 0.. IUN YMOL HUL PROJT : RWN Y: R HK Y: R/R -0. IL LOTION: :\\RWIN\TRI \-.0 TRI - IT.W (NOT ON IT) TH VNU N 0' R.O.W. ITIN

More information

Matthew Frankel 24 Drayton Street Savannah GA

Matthew Frankel 24 Drayton Street Savannah GA Matthew Frankel rayton Street Savannah G 9--8056 mfrankel@hansensavannah.com en arter nterprises One uckhead Plaza. 060 Peachtree Road, NW. Suite 800 tlanta G 005 X 0 West roughton Street. Savannah, G

More information

Location Map Project: Home2 Applicant: Buhl Investors Minnetonka I LLC Address: 6030 Clearwater Dr ( a) ±

Location Map Project: Home2 Applicant: Buhl Investors Minnetonka I LLC Address: 6030 Clearwater Dr ( a) ± ROW L N R R R RW T R T W R T I W 49 4 T RST 49 4 INT T RST INT R T W L IT W R KR R Nine Mile reek 6 T O N I 494 OUN T OR S I494 TO OR6 Subject Property Y RO 6 OUNTY RO 6 IWY 6 6 WY I IWY 6 Y 6 IW Location

More information

BXUV.V470. Fire Resistance Ratings - ANSI/UL 263. Design/System/Construction/Assembly Usage Disclaimer. Fire Resistance Ratings - ANSI/UL 263

BXUV.V470. Fire Resistance Ratings - ANSI/UL 263. Design/System/Construction/Assembly Usage Disclaimer. Fire Resistance Ratings - ANSI/UL 263 Page Bottom BXUV.V470 Fire Resistance Ratings - ANSI/UL 263 Design/System/Construction/Assembly Usage Disclaimer Authorities Having Jurisdiction should be consulted in all cases as to the particular requirements

More information

PERMIT DRAWINGS GULF COAST AMMONIA TERMINAL DOCK GULF COAST AMMONIA (GCA) GALVESTON COUNTY, TEXAS DECEMBER 2018

PERMIT DRAWINGS GULF COAST AMMONIA TERMINAL DOCK GULF COAST AMMONIA (GCA) GALVESTON COUNTY, TEXAS DECEMBER 2018 PRMIT RWINGS GUL OST MMONI TRMINL OK GUL OST MMONI (G) GLVSTON OUNTY, TXS LIST O RWINGS RWING NO. RWING TITL LTST RVISION T TITL SHT HOUSTON 2 OVRLL PROPOS SIT PLN TXS ITY SIT LOTION PROPOS SIT PLN 4 PROPOS

More information

UL Construction No. 254

UL Construction No. 254 UL Construction No. Wind-Uplift - Class 90 (See Item No. ) / Fire Not Investigated Metal Roof Deck Panels* Snap-Clad No. MSG or No. MSG min. thickness coated steel panels. Panels in. wide max., 0 in. wide

More information

P-194 Sheet Bar Measures 1 inch

P-194 Sheet Bar Measures 1 inch esigned y: No.: 9 0 N. PRK RO, SUIT 0 HOLLYWOO, LORI 0 PHON: (9) - X: (9) 08- Janine M. lexander, P.. P.. No. 9, L PVMNT RSTORTION N MRKING TILS Y JM rawn y: hecked y: K P-9 SRIPTION WTR MIN RPLMNT PROGRM

More information

ESR-2403 Reissued October 1, 2009 This report is subject to re-examination in one year.

ESR-2403 Reissued October 1, 2009 This report is subject to re-examination in one year. ICC-ES Evaluation Report ESR-403 Reissued October, 009 This report is subject to re-examination in one year. www.icc-es.org (800) 43-6587 (56) 699-0543 A Subsidiary of the International Code Council DIVISION:

More information

NOT FOR CONSTRUCTION:

NOT FOR CONSTRUCTION: ' - 8 /8" 4' - 7 7/8" 9' - 4" ' - 8 /8" 4' - ' - 8 /8" ' - 8 /8" 4' - 7 7/8" ' - 8" 9' - 4" ' - 8 /8" 4' - ' - 8 /8" ' - 8 /8" 4' - ' - 8 /8" 9' - 4" 4' - 7 7/8" ' - 8 /8" 0' - 5 /" / / - ROOM UNIT - ROOM

More information

BUNCHE MANOR, UNIT 32 BLK A - LOTS 1-10 & BLK B - LOTS , 2026, 2040, 2100 & 2126 ORANGE CENTER BLVD & 800 S. TAMPA AVE ORLANDO, FLORIDA 32807

BUNCHE MANOR, UNIT 32 BLK A - LOTS 1-10 & BLK B - LOTS , 2026, 2040, 2100 & 2126 ORANGE CENTER BLVD & 800 S. TAMPA AVE ORLANDO, FLORIDA 32807 IVIL MOLITION PLNS OR LOTION MP UNH MNOR, UNIT LK - LOTS -0 & LK - LOTS - onsultant: PROJT SIT 0, 0, 00, 00 & ORNG NTR LV & 00 S. TMP V ORLNO, LORI 0 PRPR OR PROJT TM PPLINT/OWNR KI L RO, SUIT 0 WINTR

More information

TECH BULLETIN SIP No Subject: Fire Resistive Assemblies Date: November 2007 (Revised May 2017) Roof/Ceiling: 1-Hour Rating

TECH BULLETIN SIP No Subject: Fire Resistive Assemblies Date: November 2007 (Revised May 2017) Roof/Ceiling: 1-Hour Rating TECH BULLETIN SIP No. 2018 Subject: Fire Resistive Assemblies Date: November 2007 (Revised May 2017) ASTM E 119 (UL 263) tests have been conducted on R-Control SIPs to develop fire resistance assemblies.

More information

AIRFORCE CIVIL ENGINEERING CENTER DYNAMIC PROTOTYPE DEVELOPMENT GENERAL MAINTENANCE/PERIODIC INSPECTION HANGAR

AIRFORCE CIVIL ENGINEERING CENTER DYNAMIC PROTOTYPE DEVELOPMENT GENERAL MAINTENANCE/PERIODIC INSPECTION HANGAR esigned y: rawn y: hecked y: Reviewed y: : ontract No: SIZ: IL NM: 22" x 34" pproved US RMY NGINR ISTRIT ORPS O NGINRS 1 RWING LIST NUMR NM -1 OVR -1 MOULS -2 MOULS -3 MOULS -4 MOULS -5 PROO O ONPT (PO)

More information

Versatrac R-System Stock Extrusions, Clips and Accessories

Versatrac R-System Stock Extrusions, Clips and Accessories Versatrac R-System Extrusions are available in 300 series (for 3 3/4" walls) and 400 series (for 4 7/8" walls). Standard finishes are Satin Metallic Bronze, Satin Black, Satin White Baked Enamel, and Clear

More information

Versatrac R-System Stock Extrusions, Clips and Accessories

Versatrac R-System Stock Extrusions, Clips and Accessories Versatrac R-System Extrusions are available in 300 series (for 3 3/4" walls) and 400 series (for 4 7/8" walls). Standard finishes are Satin Metallic Bronze, Satin Black, Satin White Baked Enamel, and Clear

More information

Site Context 1 : 1500 SITE STATISTICS LOT: (NOT TO SCALE) 27,845.44SM 60.40SM EXISTING LOT AREA EXISTING LOT FRONTAGE (COLERAINE DRIVE)

Site Context 1 : 1500 SITE STATISTICS LOT: (NOT TO SCALE) 27,845.44SM 60.40SM EXISTING LOT AREA EXISTING LOT FRONTAGE (COLERAINE DRIVE) RVISIONS, RORS. // View erial L L L SIT SUR INX and TULTION L - LNSP / SO R - ONRT PV R - SPLT PV R - RLIM SPLT PV R - L m L9 L mm m :,9.SM -.%,.SM -.%,.SM -.%,.SM -.% m Site reas Index : UILIN "" I L

More information

A100 TOWNHOUSE CONCEPT SITE. No. Description Date SITE A100 TOWNHOUSE CONCEPT. Owner. Project Number Date. Issue Date.

A100 TOWNHOUSE CONCEPT SITE. No. Description Date SITE A100 TOWNHOUSE CONCEPT.   Owner. Project Number Date. Issue Date. SIT 00 0 0 0 TOWNOUS ONPT ' - ' - " 0 SIT /" = '- TOWNOUS ONPT No. escription ate ddress ddress ddress SIT ate Issue ate rawn y uthor OutKast esigns Po ox 0 olusa, 99 scott@outkastdesigns.com 00 /" = '-

More information

FASTENERS BUILDING DEPARTMENT

FASTENERS BUILDING DEPARTMENT FASTENERS BUILDING DEPARTMENT 952-446-1660 WWW.CITYOFMINNETRISTA.COM This handout is intended only as a guide and is based in part on the 2015 Minnesota Residential Code, Minnetrista City ordinances, and

More information

FIRE PROTECTION GENERAL NOTES 1. DO NOT SCALE FROM THESE DRAWINGS. FIRE PROTECTION LEGEND

FIRE PROTECTION GENERAL NOTES 1. DO NOT SCALE FROM THESE DRAWINGS. FIRE PROTECTION LEGEND SYMOLS IR PROTTION LN SRIPTION XISTIN PIP TO RMIN NW PIPIN NW ONL PNNT SPRINLR NW UPRIT SPRINLR IR PROTTION NRL NOTS 1. O NOT SL ROM TS RWINS. 2. LL WOR SLL PRORM IN ORN WIT LL PPLIL N OPT RULTIONS INLUIN

More information

MTROPOLITN STT UNIVRSITY SIN UTION NTR 80 St. Peter Street, Ste. 00 Saint Paul, MN 0..0 bwbr.com onsultants opyright 0 LKP ngineers, Inc. 9 West ounty Rd, Suite 00 Saint Paul, MN - Phone:.. ax:.. www.lkpb.com

More information

2x6. 2x8. 2x10. Size. 2-2x10 8'-5" w/ 2 NJ 7'-3" w/ 2 NJ

2x6. 2x8. 2x10. Size. 2-2x10 8'-5 w/ 2 NJ 7'-3 w/ 2 NJ 1 Rafter Size Spacing Allowable span 24" 11'-9" 24" 2x6 14'-1" 2x4 12" 15'-6" 12" 24" 14'-10" 24" 2x8 18'-2" 2x6 12" 20'-5" 12" 24" 18'-2" 24" 2x10 22'-3" 2x8 12" 25'-8" 12" 24" 21'-0" 24" 2x12 25'-9"

More information

BB1068 / BB1099 SERIES

BB1068 / BB1099 SERIES 068 / 099 SRIS LL RING TMPLT UTT HINGS HVY WIGHT Non-handed ase material: steel for series 068, stainless steel for series 099 High grade plated finishes Standard non-rising non-removable pin (NRP) Standard

More information

KEY W EST HARBOR MONROE COUNTY, FLORIDA POST-HURRICANE IRMA EXAMINATION SURVEY FY17 8, 12, 26, 30 & 34-FOOT PROJECT LOCATION MAP SHEET INDEX

KEY W EST HARBOR MONROE COUNTY, FLORIDA POST-HURRICANE IRMA EXAMINATION SURVEY FY17 8, 12, 26, 30 & 34-FOOT PROJECT LOCATION MAP SHEET INDEX 10 9 8 7 6 5 3 2 1 US rmy orps of ngineers Jacksonville istrict L M PNSOL G O R G I N STY ON THIS JO PNS ON YOU TLLHSS JKSONVILL SHT 22 TLNTI ORLNO SHT 21 SHT 23 GUL TMP OO ON escription SHT 18 SHT 20

More information

ADDENDUM NUMBER 01 TO THE BID DOCUMENTS

ADDENDUM NUMBER 01 TO THE BID DOCUMENTS SN OS VRRN OMMUNITY OLL ISTRIT NUM NUMR 0 TO T I OUMNTS I NUMR: 00.057 #-0 Student Services enter rchitectural arrier Removal vergreen Valley ollege ddendum ate: anuary 7, 07. This addendum shall be considered

More information

A0.1 CEPEO - CONSEIL DES ÉCOLES PUBLIQUES DE L'EST DE L'ONTARIO LIFE SAFETY PLANS & FIRE SEPARATIONS GROUND FLOOR LIFE SAFETY EXIT DOOR WIDTHS

A0.1 CEPEO - CONSEIL DES ÉCOLES PUBLIQUES DE L'EST DE L'ONTARIO LIFE SAFETY PLANS & FIRE SEPARATIONS GROUND FLOOR LIFE SAFETY EXIT DOOR WIDTHS HOISTWY PLN VIW mm OOR WI T H...... K J. TOLR MOUL J PRSHOOL MOUL YR ST RM. a JNITOR MH/L L. a ST ROOM KY PLN: I H YM STOR b PRINIPL OI a. YMNSIUM MTIN ROOM LIRRY V.P. OI b MIN LINT: PO - ONSIL S ÉOLS

More information

CENTER LINES OF OPTICAL CONNECTOR NOTE 2 CENTER LINES OF OPTICAL CONNECTOR CFP2-BASELINE-DRAWING 1L A3-B1-SW006 1/15 DETAIL B A16

CENTER LINES OF OPTICAL CONNECTOR NOTE 2 CENTER LINES OF OPTICAL CONNECTOR CFP2-BASELINE-DRAWING 1L A3-B1-SW006 1/15 DETAIL B A16 02 4.0 7 04 NTR LINS O OPTIL ONNTOR NOT 2 MSURMNT IRLOW IRTION TIL 1 01 07 -- 17 1 05 0 20 19 NTR LINS O OPTIL ONNTOR 12 15 0 11 NOT. r 2-0 NOT.5 f PIN 5 PIN 104 2-21 14 1 4-09 TOP N OTTOM LIMITS O TH

More information

Shaft Wall SYSTEMS 210 INSTALLATION 211. Shaft Wall systems are fire rated non-load bearing walls used for shafts and service ducts.

Shaft Wall SYSTEMS 210 INSTALLATION 211. Shaft Wall systems are fire rated non-load bearing walls used for shafts and service ducts. SYSTEMS 210 INSTALLATION 211 GENERAL REQUIREMENTS 211 FRAMING 212 PLASTERBOARD LAYOUT 213 PLASTERBOARD FIXING 214 CONSTRUCTION DETAILS 217 Shaft Wall Shaft Wall systems are fire rated non-load bearing

More information

Drywall, Wood and Truss Uplift

Drywall, Wood and Truss Uplift Drywall, Wood and Truss Uplift Drywall (gypsum board) has to: provide rigidity provide aesthetics provide fire protection not leak air Concerns Wood moves. Drywall does not move. Interesting problem. The

More information

Fastener Schedule. a, b, c. FASTENER Roof 3-8d (2 1 / ) / ) 3-10d. 3-10d ( ) 3-16d box nails. (3 1 2 toe nails on one side

Fastener Schedule. a, b, c. FASTENER Roof 3-8d (2 1 / ) / ) 3-10d. 3-10d ( ) 3-16d box nails. (3 1 2 toe nails on one side ITEM 1 DESCRIPTION OF BUILDING ELEMENTS Blocking between joists or rafters to top plate, toe 2 Ceiling joists to plate, toe 3 4 5 6 Ceiling joists not attached to parallel rafter, laps over partitions,

More information

Installation Instructions Model # TEL-100 / 200 Manual Locking or Self Locking

Installation Instructions Model # TEL-100 / 200 Manual Locking or Self Locking INSTLLTION INSTRUTIONS TL-100 / 200 GSS-oors TL 1-406-212-2334 MIL rg@gssdoors.com W www.gssdoors.com GSS oors (406) 212-2334 (406) 897-2121 rg@gssdoors.com www.gssdoors.com TM Multi-Point eadbolt Installation

More information

TOLL FREE:(888) FAX:(941) ASSEMBLY of ProTEC CONCRETE STRUCTURAL INSULATED PANEL

TOLL FREE:(888) FAX:(941) ASSEMBLY of ProTEC CONCRETE STRUCTURAL INSULATED PANEL ASSEMBLY of ProTEC CONCRETE STRUCTURAL INSULATED PANEL The ProTEC panels are manufactured with grooves on all four sides to accept the steel components. This grooving applies to the regular panel whose

More information

Office/Retail/Restaurant Space For Lease

Office/Retail/Restaurant Space For Lease or more information or to arrange a showing, please contact: MIK IUTTRI, SIOR MIK@MOMMRIL.OM 40.75.3200 X305 LS MITLL IV LS@MOMMRIL.OM 40.75.3200 X307 N UVIN NIL@MOMMRIL.OM 40.75.3200 X308 xclusive gent:

More information

Load Tables, Technical Data and Installation Instructions

Load Tables, Technical Data and Installation Instructions W22. W22. W22. W22. W22 W22.. Simpson Strong-Tie Fastening Systems Structural Wood-to-Wood Connections Including Ledgers Designed to provide an easy-to-install, high-strength alternative to through-bolting

More information

SECTION R507 DECKS DECKING LEDGER BOARD BEAM. FOOTING BEAM SPAN CANTILEVER For SI: 1 inch = 25.4 mm FIGURE R507.2 DECK CONSTRUCTION

SECTION R507 DECKS DECKING LEDGER BOARD BEAM. FOOTING BEAM SPAN CANTILEVER For SI: 1 inch = 25.4 mm FIGURE R507.2 DECK CONSTRUCTION SECTION R507 DECKS R507.1 Application. The provisions of this section shall provide prescriptive requirements for the design and construction of all uncovered, wood-framed, single-span exterior decks.

More information

VISION IMPACT+ OBJECT DETECTOR HIGHLIGHTS APPLICATIONS

VISION IMPACT+ OBJECT DETECTOR HIGHLIGHTS APPLICATIONS is a machine vision turnkey solution for object detection applications in the T&L industry, including the new P Smart amera, infrared illuminators, connection bo and cables. The P Smart amera is an embedded

More information

5' Multi-Purpose Easi-Frame Assembly Instructions

5' Multi-Purpose Easi-Frame Assembly Instructions 1 5' Multi-Purpose asi-frame ssembly Instructions Using this frame with: n XL Joinery door pair (using hinges) with either a fixed or hinged asi-frame emi Panel XL Panels used as a i-fold with a fixed

More information

MAGNUM BOARD INTERIOR INSTALLATION GUIDELINES

MAGNUM BOARD INTERIOR INSTALLATION GUIDELINES TECHNICAL BULLETIN No.: 090509-1405 Subject: Issue Date: September 4, 2009 Issue No.: II MAGNUM BOARD INTERIOR INSTALLATION GUIDELINES 1. CUTTING MAGNUM BOARD You can easily cut Magnum Board with carbide

More information

8' Multi-Purpose Easi-Frame Assembly Instructions

8' Multi-Purpose Easi-Frame Assembly Instructions 1 8' Multi-Purpose asi-frame ssembly Instructions Using this frame with: n XL Joinery door pair (using hinges) with either fixed or hinged asi-frame side panels or emi Panels on either side asi-frame Panels

More information

UNA-CLAD Metal Roof Systems

UNA-CLAD Metal Roof Systems UNA-CLAD Metal Roof Systems Underwriters Laboratories (UL) UL Roof Deck Constructions and P Assemblies Factory Mutual Approvals (FM) Table of Contents 1.01 EXTERNAL FIRE RATINGS... 7 Assemblies are updated.

More information

WAYNE STATE UNIVERSITY ART ROOMS 250 & 254 RENOVATION 150 ART BUILDING DETROIT, MI WSU PROJECT NUMBER:

WAYNE STATE UNIVERSITY ART ROOMS 250 & 254 RENOVATION 150 ART BUILDING DETROIT, MI WSU PROJECT NUMBER: T PROJT TM: OLUMN LIN SIGNTION UILING STION UT INITOR - - PRTIL STION UT INITOR - LVTION INITOR INTRIOR LVTION INITOR X-- L LG O OL ON ONT ONST OOR ORR PT /W F I IM ISP N S /W WG F J L L LV Q W XIST XT

More information

OUTSIDE STRIKE INSIDE. TEMPLATE-S6100 Devices covered by this template: Panic Rim Device and Fire Rim Device. FINISHED FLOOR

OUTSIDE STRIKE INSIDE. TEMPLATE-S6100 Devices covered by this template: Panic Rim Device and Fire Rim Device. FINISHED FLOOR TRIM MOUNTING HOLS: 1. rill 7/16 dia. Thru Holes 4X THIS SI UP FOR LHR OOR 4X.375 dia. US FOR SXOLTS STRIK MOUNTING HOLS: 1. rill.201 dia. (#7 rill) holes 2X. 2. Use #1/4-20 Tap JUST TH STRIK FOR PROPR

More information

ICC-ES Evaluation Report Reissued June 1, 2010 This report is subject to re-examination in one year.

ICC-ES Evaluation Report Reissued June 1, 2010 This report is subject to re-examination in one year. ICC-ES Evaluation Report ESR-2648 Reissued June 1, 2010 This report is subject to re-examination in one year. www.icc-es.org (800) 423-6587 (562) 699-0543 A Subsidiary of the International Code Council

More information

ESR-2648 Reissued May 1, 2012 This report is subject to renewal June 1, 2013.

ESR-2648 Reissued May 1, 2012 This report is subject to renewal June 1, 2013. ICC-ES Evaluation Report ESR-2648 Reissued May 1, 2012 This report is subject to renewal June 1, 2013. www.icc-es.org (800) 423-6587 (562) 699-0543 A Subsidiary of the International Code Council DIVISION:

More information

CANYON TV CABINET ASSEMBLY INSTRUCTIONS

CANYON TV CABINET ASSEMBLY INSTRUCTIONS NYON TV NT SSMLY NSTRUTONS MPORTNT PLS R OR YOU ONTNU URTR WRNN N NSTRUTONS NR MPORTNT: RTN TS NSTRUTONS OR UTUR RRN. U TO T SZ O TS PROUT W ROMMN TT T S SSML N T ROOM NTN OR US. WN YOU R RY TO STRT,MK

More information

ARCHITECTURAL STICK SYSTEMS

ARCHITECTURAL STICK SYSTEMS ABOUT THE STICK SYSTEMS: The Steelcraft Architectural Stick Systems are designed to fit virtually all construction requirements for commercial building applications. These frame assemblies are fabricated

More information

H BUILDING RENOVATIONS

H BUILDING RENOVATIONS LUQURQU, NW MXIO, US 00 Gold venue, SW Studio 00 Simms Tower lbuquerque, New Mexico 870 US tel. 0 H UILING RNOVTIONS OWNR / SIGN TM VIINITY MP (Q ZON TLS PG FZ) N KY PLN NOVMR 00 / SIGN TM LR/RHITT ROH

More information

THE ENGINEERED WOOD ASSOCIATION

THE ENGINEERED WOOD ASSOCIATION D A T A F I L E APA Performance Rated Rim Boards A rim board is the wood component that fills the space between the sill plate and bottom plate of a wall or, in second floor construction, between the top

More information

Brio. Weatherfold 5c 80. Codes B WC 4-80 S H SS. Sets all sets shown with hinge type H except BW2L/R-80SR. No finishes shown. Brio Weatherfold 5c

Brio. Weatherfold 5c 80. Codes B WC 4-80 S H SS. Sets all sets shown with hinge type H except BW2L/R-80SR. No finishes shown. Brio Weatherfold 5c rio odes INSTW1 RV - UG 17 Weatherfold 5c 80 rio ustralia P: +1 2 8718718 W: brio.com.au : brio.sales@allegion.com rio UK P: +44 191 2291224 W: briouk.com : brio.sales.uk@allegion.com rio US P: +1 585

More information

A B C D 12.PROVIDE PLUMBING PER STATE PLUMBING CODE REQUIREMENTS 13.HVAC SYSTEM TO BE DESIGN BUILD, PROVIDE PER STATE CODE REQUIREMENTS.

A B C D 12.PROVIDE PLUMBING PER STATE PLUMBING CODE REQUIREMENTS 13.HVAC SYSTEM TO BE DESIGN BUILD, PROVIDE PER STATE CODE REQUIREMENTS. PL LG PRTITIS, RS ITMS T RMV XISTIG R XISTIG PRTITI W R FULL HIGHT PRTITI PRTIL HIGHT PRTITI TRT LIMIT LI RM M 0 W T W IMSI T TH F F FRMIG R MSRY T W STRUTI, TYP. IMSI T TH F F FIISH T XISTIG STRUTI IMSI

More information

B. Sequencing: Schedule installation to keep sheathing exposure to UV within the manufacturer s recommended limits.

B. Sequencing: Schedule installation to keep sheathing exposure to UV within the manufacturer s recommended limits. SECTION 06 16 43 GYPSUM SHEATHING PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Exterior GMF gypsum sheathing. 2. Joint treatment materials. 3. Panel and penetration joint and fastener treatment.

More information

LEGACY REPORT. (800) (562) A Subsidiary of the International Code Council. *Revised September 2003

LEGACY REPORT.  (800) (562) A Subsidiary of the International Code Council. *Revised September 2003 ICC-ES Evaluation Report ER-580* Reissued January 00 www.icc-es.org (800) 4-6587 (56) 699-054 A Subsidiary of the International Code Council Legacy report on the 997 Uniform Building Code DIVISION: 05

More information

NEW HOME WARRANTY A REFERENCE GUIDE FOR TYPICAL WALL AND WINDOW DETAILS (RAINSCREEN SYSTEM) SHOWN AS FIBRE CEMENT CLADDING

NEW HOME WARRANTY A REFERENCE GUIDE FOR TYPICAL WALL AND WINDOW DETAILS (RAINSCREEN SYSTEM) SHOWN AS FIBRE CEMENT CLADDING NEW HOME WARRANTY A REFERENCE GUIDE FOR TYPICAL WALL AND WINDOW DETAILS (RAINSCREEN SYSTEM) SHOWN AS Reference Guide 0.1 GENERAL 0.1 Reference Guide 0.2 Index 0.3 Disclaimer & Limitations 0.4 General Notes

More information

NMR PHASE 1 - DUS TO 72ND AVE STATION REGIONAL TRANSPORTATION DISTRICT

NMR PHASE 1 - DUS TO 72ND AVE STATION REGIONAL TRANSPORTATION DISTRICT L S TRK L N TRK 2 4 5 6 8 0 " 5 6" 5 6" 5 6" 5 6" 5 6" 4 5 " 6" 6" 6" 6" LOW (TYP) L R L R L PIR 2 6" 5 0" 2 6" 0 0" H STTION 5 " 5 0" 0 8 " RSH RRIR PLN * NL IS MSUR ROM L PIR TO L IRR INITS LIMITS O

More information

Horizontal Shaft Wall

Horizontal Shaft Wall SYSTEMS 317 INSTALLATION 319 GENERAL REQUIREMENTS 319 FRAMING 319 PLASTERBOARD LAYOUT 320 PLASTERBOARD FIXING 320 CONSTRUCTION DETAILS 321 Horizontal Shaft Wall Horizontal Shaft Wall is constructed in

More information

Column and Beam Fire Protection SYSTEMS 335 INSTALLATION 337 GENERAL REQUIREMENTS 337 FRAMING 337

Column and Beam Fire Protection SYSTEMS 335 INSTALLATION 337 GENERAL REQUIREMENTS 337 FRAMING 337 SYSTEMS 335 INSTALLATION 337 GENERAL REQUIREMENTS 337 FRAMING 337 PLASTERBOARD LAYOUT 337 PLASTERBOARD FIXING 337 CONSTRUCTION DETAILS 341 Column and Beam Fire Protection Column and beam protection systems

More information

PRIMED STRAND REVERSIBLE SHAKE

PRIMED STRAND REVERSIBLE SHAKE PRIMED STRAND REVERSIBLE SHAKE PRIOR TO INSTALLATION Inspect product for any issues before installing (breakage, surface defects, foreign objects). Do not install questionable product. Report any problems

More information

APA Performance Rated Rim Boards

APA Performance Rated Rim Boards D a t a F i l e APA Performance Rated Rim Boards A Rim Board is the wood component that fills the space between the sill plate and bottom plate of a wall or, in second floor construction, between the top

More information

JOIST DETAILS Plate nail, 16d (0.15" x 1 ") at 1 on-center Blocking panel: 1 1 8" TJ Rim Board, 1 1 TimberStrand SL or TJI joist Toe nail, 10d (0.11" x ") at on-center A1 CS BEAM DETAILS L1 eb stiffener

More information

SDWH TIMBER-HEX Screw

SDWH TIMBER-HEX Screw Simpson Strong-Tie Fastening Systems Structural Wood-to-Wood Connections, Including Ledgers Double-barrier coating provides corrosion resistance equivalent to hot-dip galvanization, making it suitable

More information

*Revised September 1, 2003

*Revised September 1, 2003 LEGACY REPORT ER-580* Reissued January, 00 ICC Evaluation Service, Inc. www.icc-es.org Business/Regional Office # 560 Workman Mill Road, Whittier, California 9060 # (56) 699-054 Regional Office # 900 Montclair

More information

DW HORIZONTAL INSTALLATION

DW HORIZONTAL INSTALLATION AR-PJ-01-DW2H 2" HORIZONTAL PANEL JOINT AR-PJ-02-DW2H 2" VERTICAL PANEL JOINT AR-PJ-03-DW2H 3" HORIZONTAL PANEL JOINT AR-PJ-04-DW2H 3" VERTICAL PANEL JOINT AR-PJ-05-DW2H CUSTOM REVEAL AR-PJ-06-DW2H DW-2000S

More information

Best Materials LLC distributes backer rod, caulking and sealants for all types of EIFS joints and penetration sealing applications.

Best Materials LLC distributes backer rod, caulking and sealants for all types of EIFS joints and penetration sealing applications. Best Materials LLC distributes backer rod, caulking and sealants for all types of EIFS joints and penetration sealing applications. EXTERIOR INSULATION & FINISH SYSTEM CONSTRUCTION Data Published Courtesy

More information

SINGLE TRACK BYPASS (patent pending) barn door hardware

SINGLE TRACK BYPASS (patent pending) barn door hardware SINGLE TRACK BYPASS (patent pending) barn door hardware Installation Manual What is included in your kit: Part number Part name Quantity 1 Inner door hanger 2 2 Outer door hanger 2 3 5/16 x 1.5 lag bolts

More information

HOLLOW METAL DOOR/WINDOW SYSTEM FOR THERMALSAFE CF WALLS WINDOW ASEMBLY GUIDE PIONEERING INSULATED METAL PANEL TECHNOLOGY

HOLLOW METAL DOOR/WINDOW SYSTEM FOR THERMALSAFE CF WALLS WINDOW ASEMBLY GUIDE PIONEERING INSULATED METAL PANEL TECHNOLOGY HOLLOW METAL DOOR/WINDOW SYSTEM FOR THERMALSAFE CF WALLS WINDOW ASEMBLY GUIDE PIONEERING INSULATED METAL PANEL TECHNOLOGY PIONEERING INSULATED METAL PANEL TECHNOLOGY TABLE OF CONTENTS DETAIL TITLE PAGE

More information

The better way to build TM. Installation Manual ROOF SIPs

The better way to build TM. Installation Manual ROOF SIPs The better way to build TM Installation Manual ROOF SIPs August 2017 ROOF SIPs Installation Manual Table of Contents Topics General Requirements.................................... 3 Materials..............................................

More information

ICC-ES Evaluation Report

ICC-ES Evaluation Report ICC-ES Evaluation Report www.icc-es.org (800) 423-6587 (562) 699-0543 ESR-2608 Reissued January 2016 This report is subject to renewal January 2017. A Subsidiary of the International Code Council DIVISION:

More information

ESR-1254 * DELETED BY CITY OF LOS ANGELES. Reissued April 1, 2006 This report is subject to re-examination in one year.

ESR-1254 * DELETED BY CITY OF LOS ANGELES.   Reissued April 1, 2006 This report is subject to re-examination in one year. ESR-1254 Reissued April 1, 2006 This report is subject to re-examination in one year. www.icc-es.org Business/Regional Office 5360 Workman Mill Road, Whittier, California 90601 (562) 699-0543 Regional

More information

Flashing Materials. Rough Opening Preparation

Flashing Materials. Rough Opening Preparation Installation Instructions for CertainTeed New Construction Windows Handling vinyl windows CAUTION: Always store vinyl windows and doors in an upright position on a slight angle. Never lay them flat or

More information

CFDTT-01. Control Joint Study (General)

CFDTT-01. Control Joint Study (General) Trim Method Classic Method Notes: Control joints are required and should be located by the designer at the following locations on the construction documents: 144 sf (13.4 sm) is the maximum overall area

More information

Versatrim Side-Snap Frame

Versatrim Side-Snap Frame Versatrim Side-Snap Frame net door width finished opening width rough opening width (finished opening width plus 1 1/2") Figure 1 Cross section of strike and hinge jambs The rough opening width is equal

More information

rondo exangle drywall finishing sections

rondo exangle drywall finishing sections rondo exangle drywall finishing sections SUMMARY The EXANGLE range of building board finishing profiles are designed to give plasterers a clean, defined edge on straight or curved details for internal

More information

OHIO RIVER BASIN HANNIBAL LOCKS & DAM CONDUCTOR RAIL REPLACEMENT MONROE COUNTY, OHIO W 911W N17B8001 CONTRACT NO. SEPTEMBER 2016

OHIO RIVER BASIN HANNIBAL LOCKS & DAM CONDUCTOR RAIL REPLACEMENT MONROE COUNTY, OHIO W 911W N17B8001 CONTRACT NO. SEPTEMBER 2016 2 4 5 6 7 8 9 0 US rmy orps of ngineers T US rmy orps of ngineers Pittsburgh istrict OHIO RIVR SIN SRI PTI ON HNNIL LOKS & M M RK ONUTOR RIL RPLMNT MONRO OUNTY, OHIO N.T.S. N.T.S. SINTURS IX LOW INIT OIIL

More information

DIVISION 6 WOOD AND PLASTICS

DIVISION 6 WOOD AND PLASTICS DIVISION 6 WOOD AND PLASTICS PART 1 - GENERAL 1.01 SUMMARY A. This Section includes the following: 1. Wood framing. 2. Wood supports. 3. Wood blocking. 4. Wood cants. 5. Wood nailers. 6. Wood furring.

More information

SSRLS-3 / SSRLU-3 Installation Instructions

SSRLS-3 / SSRLU-3 Installation Instructions 5mm Hex Nut Upper Telescoping hannel & Screws Packing List QTY. ITM 1 Top Telescoping hannel 1 ottom Telescoping hannel w/ self drilling screw 15" 18" 1 Top and ottom Rod with connecting arm 25-½ 2 ¼ -

More information

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: LAMINATED VENEER LUMBER SECTION: LAMINATED STRAND LUMBER REPORT HOLDER:

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: LAMINATED VENEER LUMBER SECTION: LAMINATED STRAND LUMBER REPORT HOLDER: 0 Most Widely Accepted and Trusted ICC ES Report ICC ES 000 (800) 423 6587 (562) 699 0543 www.icc es.org ESR 03 Reissued 02/2017 This report is subject to renewal 02/2019. DIVISION: 06 00 00 WOOD, PLASTICS

More information

KS SERIES - VERTICAL INSTALLATION

KS SERIES - VERTICAL INSTALLATION CS-DS-01-KSV CS DISCLAIMER CS-PJ-01-KSV KS42SL EXPANDED PANEL JOINT CS-PJ-02-KSV KS42SL ENGAGED PANEL JOINT CS-PJ-03-KSV KS45SL EXPANDED PANEL JOINT CS-PJ-04-KSV KS45 FLAT ENGAGED PANEL JOINT CS-PJ-05-KSV

More information

Code Review The following is a review of selected portions of the International Building Code 2015 (IBC2015) which apply to this project.

Code Review The following is a review of selected portions of the International Building Code 2015 (IBC2015) which apply to this project. ESIGNE Y: RWN Y: HEKE Y: TE: SLE: //07 /" = '-0" OVER SHEET Hoover Metal uildings, Inc. PROJET FOR: PPROVLS: TE REVISIONS: Y: UILING "" P.O. ox 99 Lexington, S 907 (80)9-98 ode Review The following is

More information

MAT106: Wall Framing. AMERICAN FOREST & PAPER ASSOCIATION American Wood Council Engineered and Traditional Wood Products

MAT106: Wall Framing. AMERICAN FOREST & PAPER ASSOCIATION American Wood Council Engineered and Traditional Wood Products MAT106: This portion of the program will address the code requirements for wall framing, although we won t address bracing in this section. The program contains a separate bracing section. 1 FASTEN PLATES

More information

Installation and Assembly: Projector Ceiling/Wall Mount

Installation and Assembly: Projector Ceiling/Wall Mount Installation and ssembly: Projector eiling/wall Mount Model# Max UL Load apacity EX, EX-S, EX-W, EX, EX-S, used with PRS projector mount 25 lb (11.3 kg) EX-W, EX, EX-S, EX-W used with PRG projector mount

More information

ECOUSTIC VENEER INSTALLATION + CARE

ECOUSTIC VENEER INSTALLATION + CARE ECOUSTIC VENEER INSTLLTION + CRE WLL + CEILING INSTLLTION COMPONENTS SUPPLIED IN ECH OX ecoustic Veneer panels Sold in boxes of 4 panels per finish Clips 24 supplied in each box Expressed Joint Sets 4

More information

COMPOSITE SIDING INSTALLATION GUIDE

COMPOSITE SIDING INSTALLATION GUIDE CENTURY HOME LIVING COMPOSITE SIDING INSTALLATION GUIDE Read all instructions prior to installing any siding product. Failure to install and finish this product in accordance with all local building codes,

More information

3.1 General Provisions

3.1 General Provisions WOOD FRAME CONSTRUCTION MANUAL 107 3.1 General Provisions 3.1.1 Prescriptive Requirements The provisions of this Chapter establish a specific set of resistance requirements for buildings meeting the scope

More information

Plasterboard Ceiling Systems

Plasterboard Ceiling Systems Plasterboard Ceiling Systems 400C Issue 1 2 Plasterboard Ceiling Systems Contents Standard Ceilings Design...3-7 Introduction... 3 Fire Ratings... 3 Systems Mass... 3 Decoration... 3 General Construction

More information

Monogram 48" Built-In Side-by-Side Refrigerator

Monogram 48 Built-In Side-by-Side Refrigerator Monogram 48" uilt-in Side-by-Side Refrigerator STION 1 FLUSH INST INSTLLTION STION 2 STNR INSTLLTION 1/4" FRM PNLS 3/4" OVRLY PNLS OVRLL IMNSIONS FTR PNL INSTLL FLUSH INST INSTLLTION 50" (127.0) 26" (66.0)

More information

900 SERIES WALL PANELS

900 SERIES WALL PANELS CI-DS-01-900 CI-PP-01-900 CI-PJ-01-900 CI-PJ-02-900 CI-PJ-03-900 CI-BS-01-900 CI-BS-02-900 CI-BS-03-900 CI-BS-04-900 CI-BS-05-900 CI-OC-01-900 CI-OC-02-900 CI-IC-01-900 CI-FO-01-900 CI-FO-02-900 CI-FO-03-900

More information

barrier free living board presentation june 14 th n17015 / / jcj architecture

barrier free living board presentation june 14 th n17015 / / jcj architecture board presentation june 4 th n705 / 07-064 / jj arhiteture square footage analysis square footage analysis uilding ore Spaes uilding ore Spaes uilding ore Spaes arrier Free Living Supportive Housing Shared

More information

STEVE ENNIS ARCHITECT 1108 EAST JACKSON STREET MEDFORD, OREGON 97504

STEVE ENNIS ARCHITECT 1108 EAST JACKSON STREET MEDFORD, OREGON 97504 ATTACH TO STRUC- TURE ABOVE 1/8"Ø BOLT W/ LOCKING NUT #12 WIRE TIE IN PLANE EACH TEE ANGLED 45 FROM HORIZ ATTACH 2" FROM INTERSECTION COMPRESSION POST LOCATE WITHIN 2" OF TEE INTERSECTION SIZE STRUTS FOR

More information

VE15 & VE25 Home Elevator

VE15 & VE25 Home Elevator If In oubt - sk Safe Working Load = 0 Ib levator Power Supply = 0Vac Single Phase. mp RO. levator ontrol Voltage = Vdc levator Refer to V 900 for aperture details Refer to SK0 for structural details Refer

More information

Part No. Thread Size B Design Load Approx. Wt./100 A in. (mm) Lbs. (kn) Lbs. (kg)

Part No. Thread Size B Design Load Approx. Wt./100 A in. (mm) Lbs. (kn) Lbs. (kg) ttachments Fig. 3199R - eiling Flange Fig. 3199RT - eiling Flange ura-opper oated Size Range: 3 /8"-16 & 1 /2"-13 rod Material: Malleable Iron (Stainless Steel Type 304 available) Standard 3199RT is UR-OPPER

More information

Drywall, Wood and Truss Uplift

Drywall, Wood and Truss Uplift building science.com 2008 Building Science Press All rights of reproduction in any form reserved. Drywall, Wood and Truss Uplift Research Report - 0107 2001 Joseph Lstiburek Abstract: Wood moves. Drywall

More information

MONOGRAM 48" BUILT-IN SIDE-BY-SIDE REFRIGERATOR

MONOGRAM 48 BUILT-IN SIDE-BY-SIDE REFRIGERATOR MONOGRM 48" UILT-IN SI-Y-SI RFRIGRTOR STION 1 STNR INSTLLTION 1/4" FRM PNLS 3/4" OVRLY PNLS STION 2 FLUSH INST INSTLLTION STNR INSTLLTION 25 1/2" (64.8) 48" (121.9) 23 7/8" (60.7) 1 3/4" (4.4) *84" (213.4)

More information

Posi-Joist Installation Guide. A guide for storage, handling and installation of the MiTek Posi-Joist floor system

Posi-Joist Installation Guide. A guide for storage, handling and installation of the MiTek Posi-Joist floor system Posi-Joist Installation Guide A guide for storage, handling and installation of the MiTek Posi-Joist floor system Posi-Joist Installation Details A B C D F E A Masonry Wall Connection Details Blockwork

More information

FOR BOARD-TO-CABLE CONNECTION

FOR BOARD-TO-CABLE CONNECTION OR OR-TO-L ONNTION 240R SRIS TURS 1.27 mm (0.0 in.) pitch contact arrangement enables high-density mounting. ellows ensure stable contact preventing pins from bending. The bellows also have excellent stability

More information

FINISTA SLIM ALUMINIUM SYSTEM. Finista Slim Aluminium System. > Multifunctional, Versatile, Simple

FINISTA SLIM ALUMINIUM SYSTEM. Finista Slim Aluminium System. > Multifunctional, Versatile, Simple INIST SLIM LUMINIUM SYSTM inista Slim luminium System > Multifunctional, Versatile, Simple inista Slim luminium System The inista Slim luminium System is a multifunctional shelving program that will allow

More information